Loading...
HomeMy WebLinkAbout1203_Burke_JohnsRiver_MSWLF_CDLF_CDLFExp_March23LFG_FID1783268_20230328Yes / No ) Doc/Event #: 'N(: UENK I I Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: • Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). • Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. • Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). • Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): LaBella Associates (Joyce Engineering) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Van Burbach Phone: (336) 323-0092 E-mail: Vburbachalabellapc.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Johns River 2500 Marsh Trail Waste Management Facility March 21, 2023 12-03 C&D-over-MSW Landfill Morganton, NC .1600 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑ Detection Monitoring Assessment Monitoring Corrective Action T e of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells QX Methane gas monitoring data Groundwater monitoring data from private water supply wells Corrective action data (specify) Leachate monitoring data ❑ Other(specify) Surface water monitoringdata Notification attached? B No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. G. Van Ness Burbach, Ph.D., P.G. Technical Consultant (336) 323-0092 Facility Representative Name (Print) Title (Area Code) Telephone Number AffixCi1IIL@Rs*W Professional Geologist Seal �� r�.`tS f' A ,. �i._ Signature 12 D Oak Branch Dr, Greensboro, NC 27407 Facility Representative Address C-0782 NC PE Firm License Number (if applicable effective May 1, 2009) O�Z �29 SEAL c, 7349 ;, 9 0��S� Pv? ��• % •.,,��NESS BV� Po,A-1 aionno LaBella Powered by partnership. March 28, 2023 Mr. Mark Delehant Burke County General Services Director P.O. Box 219 Morganton, NC 28680 RE: Burke County, Johns River Landfill Permit Number 12-03 First Quarterly Landfill Gas Monitoring Report of 2023 Project 2212740.00, Phase 04 Dear Mark: LaBella Associates (LaBella) is submitting the attached methane monitoring results for Johns River Landfill, Permit Number 12-03. The 2023 first quarter landfill gas monitoring event was performed on March 21, 2023. During this event, gas probes GP-1S, GP-1D, GP-2S, GP-21, GP-2D, GP-4, GP-5, GP-6, GP-7, and GP-8 were monitored in accordance with the facility's Landfill Gas Monitoring Plan. The gas vents in the old C&D-over-MSW waste unit (GV-1 through GV-7) were also monitored. The facility buildings, including the scale house (GMP-1), the shop (GMP-2), the office (GMP-3), the shed (GMP-4), the shooting range (GMP-13), and the Recycling Center (GMP-14) were also monitored on March 21, 2023, as were ambient air monitoring points GMP-5 through GMP-12. The locations of the gas probes and monitoring points are depicted in Drawing 1. The monitoring data for the gas probes and buildings are summarized in the attached Landfill Gas Monitoring Data Forms. Methane was detected above the lower explosive limit (LEL) in gas probes GP-2S, GP-21, and GP-2D. Methane was initially detected above the LEL in GP-4, but at the time the Gas Extraction Unit (GEU) was down. After the GEU was restarted, the methane concentration in GP-4 dropped to below the LEL. Methane was not detected above the LEL in any other probes or ambient air locations, and methane was not detected above 25% of the LEL in any of the buildings. Methane detections and exceedances are summarized in Table 1 and Table 2, respectively. Gas probes GP-2S, GP-21, and GP-2D are a nested set located in close proximity to waste in the old C&D-over-MSW landfill and are not considered boundary probes. Similarly, GP-4 is located between the old and new landfills and is not considered a boundary probe. Hydrogen sulfide was not detected in any of the probes, monitoring points, or structures; however, it was detected in gas vents GV-1 through GV-7. Hydrogen sulfide concentrations in the gas vents ranged from 3.0 to 49.0 ppm. These are potentially dangerous concentrations of hydrogen sulfide, so precautions should be taken by any person working near the vents. If you wish, we can forward a copy of this report to Jaclynne Drummond with the NCDEQ Solid Waste Section; however, since there are no exceedances in boundary probes or structures, this is not required. A copy of this report should be maintained in the facility's records. 12-D Oak Branch Drive Greensboro, NC 27407 p (336) 323-0092 www.LabeLLapc.com e The next quarterly monitoring event is tentatively scheduled for the second quarter 2023. If we can provide any additional information, please do not hesitate to call me at (336) 323-0092. Thank you. Respectfully submitted, LaBella Associates Van Burbach, PhD, PG Sr. Technical Consultant Attachments Tables 1 & 2 Landfill Gas Monitoring Log Drawing 1- Site Map with Monitoring Locations cc: David Ingram, Burke County Burke Co. -Johns River Landfill Permit # 12-03 Table 1: Methane Detections -March 21, 2023 LFG Probe CH4 (%Vol.) CH4 (%LEL) GP-2 S 60.9 1218 GP-2 1 58.4 1168 GP-2 D 58.1 1162 GP-4 (pre-G E U restart) 5.9 118 GP-4 ( post-G EU restart) 0.1 2 Table 2: Methane Exceedances - March 21, 2023 LFG Probe CH4 (%Vol.) CH4 (%LEL) GP-2 S 60.9 1218 GP-2 1 58.4 1168 GP-2 D 58.1 1162 Notes: CH4 = Methane. %Vol. = Concentration in pecent-by-volume. %LEL = Concentration as a percent of the LEL. LEL = Lower Explosive Limit = 5%Vol for Methane. S = Shallow Screen. I = Intermediate Screen. D = Deep Screen. Burke Co., Johns River Landfill Permit #12-03 LaBella Associates NC Division of Waste Management • Solid Waste Section Landfill Gas Monitoring Data Form Notice: This forin and any atf rrnmann artached ra it are "Pubbe• Records" as definedin NC General Statute 132-1..-ts such, these d(wriments are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: �CN1`4 1� Wt 9- I.ANaG t L-.- 3v-. XE G0. Permit Number: I L - O 3 Sampling Date: 3 tf 2. % I ui Z3 NC Landfill Rule (.0500 or .1600): V -50 0 Sample Collector Name&Position: �-• k-ft+N tLNJ• Fl£tfl -T.LHN(r-(AN Gas deter Type & Serial Number: 141ad eJ t cw-) SN: ASOS/ 419 Gas Meter Calibration Date: 0-+I2_a Z L Field Calibration Date & Time 3. Z k I7.0 23 P- 1,02 C) Field Calibration Gas Type35/50 (15/15 o S' - 0 W %-C-4,t Field Calibration Gas Canister Expiration Date: Z71 Z S 1207-W Gas Meter Pump Rate: 3ccp AJ ( ttA-A' -i Ambient Air Temperature: yP S S "G Barometric Pressur((in. mmHg): 29.20 Weather Conditions: C-L¢, A Q Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g.. inside field office). Attach a test location man or drawing. Report methane readings as both % LEL and I CH, by volume. Convert 7i CH, (bp vntume) to l LEL as rolluw:s: % methane (by volume)/20 = h LEL. *Hydrogen Sulfide (H,S) gas moniurcing may he required fur Construction & Demolition Landfills (CDLFs). See individual permit condi a its and/or Facility LPG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of pay, Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % 112S* +velgmal, NOTES 09-1S LJ lotiE� 30 it to Ifv1 H.5 Ole 1AP-►a L3 109 30 0 rD ► .4 3,0 0.0 JAP- t S y I-Lzs 30 121$ (00.9 0.3 1 3$.0 (5.o P.Zr 16 Iz2te 30 0 Ill:$ S$,4 0.4 36.K 0.0 61 l l -L 5$ 0. 3 39.4 0.0 LsP-LA `t 110`4 30 6 Illb 5A IS-0 19.1 0,0 P-N LS lZ , 30 (P Z 0.1 ZD•11 0.1 0.0 FL4a41tJNN.Ny P-� iotiz - o0 0 0 Z0•-+ 0.1 010 (AP- to t� t o 3R 3o 0 d 0 ZO 5 0. l 0.0 (AP-4 L� 103t1 3o IV lb 10 18.1 7_5 0,0 %AP-b 1--� ►tst 30 00 d IH.3 5.H 0.0 t AP-1 IWI 30 0 z1.3 0.0 O,n UoAp-Z L5 t o 32 3O cb 0 !G LO.1F 0. 0. WAP-3 `3 iO3Q 30 0 LD.s 0IL -0 L4Mf-H y 0z1 30 m {6 rG 7-0-u 0.4> 0.0 %AtAQ-r- 15 (Osl 30 0 12 ZOAIv O. , 0 Vtw-1v tO5Z 30 a -LO.t'a 0.4) 0, GMP- 1053 30 e5 2.0.8 p. 4) .J Is�MP t� Iosla 30 m m 20-te 0 O VMp o1 Lj tosSd 30 0 Q5 2.o.10 •0 "9 to I OS-1 p d} -Lo •S O. 0.0 V,Af- 11 L) 1 z 1 9 30 fD 9a la ZO.S O V O, l7 NOTE. /f needed. attach additional data fitrms to include additional LFG monitoring data locations far the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND »% by volume (at facility boundary) Hydrogen Sulfide: >l % by tolume (inside structures) AND >41% by volume (at facility boundary) Certification To the best of my knowledge, the information repotted and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. SIGNATURE I (�!� v" "_ TITLE ��NV' ct £,LD E"NtCtAN Revised M,crchli.2017 ��j' l�(Q�l4tilllw�Q�f 3iLUlZo23 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Malice: Thisfarm and ate infonnanan attached to it are "Public Records" as defined tit NC General Sranae 132-L As such. these documents are nrudable far aupectinn and e randnaaau be anv Person upon request (NC General Stance 132-6). Facility Name, -JoHolsZwEt L*N-ofk t-- ByML Co Permit Number. - Sampling Date: 312 11 ZD Z 3 NC Landfill Rule (.0500 or .1600): ` Sample Collector Name & Position: �- • 1 1*1Y, Fjyv. r'F-e.b TC//NI t t$ad Gas Meter Type & Serial Number: I0IM "SIM0 50: 144CV5)H q 0�1 0s-vo Gas Meter Calibration Date: Q 112p ZZ Field Calibration Date & Time: _3/2-I j jt0 Z3 &,% 0Z-0 Field Calibration Gas Type (15115 or 9/5 :3S—z U7L/S-0 %- cwy Field Calibration Gas Canister Expiration Date: D/Z4j-t p 2V Gas Meter Pump Rate: WV Or% Ll-,-4 11 Ambient Air Temperature: 6fS-SST Barometric Pressure Glor mm Hg): 2-Cl. Z 0 Weather Conditions: C-lEA"L Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location te.g.. inside field office). Attach a test location man or drawing. Report methane readings as both r, LEL and'R CH, by volume. Convert CH, (bv volume) to k LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H:S) gas monitoring may he required for Construction & Demolition Landfills WDLFo. See individual permit conditions and/or Facility I.hG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL 9 CH4 (volume) %n 02 (volume) % CO2 (volume) %n H2S* (w "MA)- NOTES LAMP- IZ- y 01 30 co Z0.4 0.1 O.o i/I,tMP- 13 1J IZSIp 30 ip 40 45 71.0 0.0 0.0 tAMP- ILI IJ 17.Si5 30 45 0 0 ZIA 0.0 0.0 In tos4 30 QD m 0 7-0.4- 0 Fit- Cwfe- b 1140 3o (b llfti SO.Z O.ty "3�1 •�3 1 Z oef wr A9.RwAL-9iSTAate 11.30 —kjJJ- 1 1155 30 cP 7-5 tv2.9 0 • 3q, 0 U 14 i IZbb '30 0 100 S�l.0 @.(0 3-4. R $ is\)-3 y 1103 30 CP IIO-L 55.1 '&,0 3 l-a y 17-ote 3C) $�8 ►-t+i.� 56 s,H S lad-S t-% 17-09 30 S►ti I t91, 0.) 411 1OL\3-U l3 1213 3 (6 "}Rtv 3).rb j-.0 2L-1.°t 3 tp<d--4 ", iztV So 0 31-05 i91,14 Z,`'i 19.0 20 VLS3 So ell -I 00.'4 lv, l0 Z(a. 0 14 F===T NOTE: IJ'needed, attach additional datafmmns to include additional LFG monitoring data locarionsJor the facilit.l. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5%r by volume (at facility boundary) Hydrogen Sulfide: >l %r by volume (inside structures) .AND >4 % by volume (at Facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct.) am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. SIGNATURE TITLE & V 1 1 s_L A T Fe i1 N t C- f q rt Re,iscd Manh 6. ]I117 _ o� 10 _ a 0 0 a 7.x. 3\ W �� GMP-1� DJepo22. v/� o-20 GIIAIP KW $ a 3-0B-10 P�AC1A Pw x a a o // s ze 000ao HASE /� PHASE 2 PHASE 4 4.] AC s / \ H E Y6 \ SAC /4.0 AC /NLE Lu / �PZ-38+PZ-30Y PZ-22S D/�, 2zz S p0� a GP 1 AB GP-2 `� GP-2 T P NLE GP-3 P SE 8 i/ V 3 a 4.2AC PZ-35 / / / / / / l� W PZ-'16D G oPz GP-< GV-02 , - �PZ-23 4 0 Ac Pz GV-03 E PZ-1q 8�z-8D !,, _ _ - / < z �rGP� PHASE 6 / / �J Y GMP-5 ( \ GV-04� i / Pz-12 �.9 AC A _ / Z O0-1 -O5� PHASE 7, \ �� LLI 0-, O GV 4.2 AC > GMP 12 PZULu . LL GV 06 L Pz -27 Z z GV-07 — �13 .� �� �♦ nPZ-18/ I �/ i �� LE W z !P 6 P3 iso� —A� Q SSZ O p GV-07 GAS VENT W WILL U' >`� J GMP-14 GAS MONITORING POINT E m �Oti %I �, A ___ _ �•1 - - A �V GP-2 Z is,\ \ — GMP 0 \ GAS PROBE _ GMP-7 MW-30 MONITORING WELL � J 10 FOOT CONTOUR LINE PROJECT NO. I/ j _ / —8-�-h �1 —• fNW-1sU — � /� / \ ( ( _M°°=sue 2 FOOT CONTOUR 277.1002.11 \ {}' GMP-7A — — — — — / _ _ PROPERTY BOUNDARY SCALE AS SHOWN _ ... 0 MW-18 0 MW-19 GRAPHIC SCALE DRAWING NO. / l AB = ABANDONED 0 150 300 soo NLE=LONGER EXISTING (P LFG-01 (PRESUMED DESTROYED) (FEET)