Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1201_Burke_KirkseyDrive_MSWLF_March23LFG_FID1783265_20230328
Data - Email CD (data loaded: Yes / No ) Doc/Event #: 'NU UENK L I Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: • Prepare one form for each individually monitored unit. • Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. • Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). • Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): LaBella Associates (Joyce Engineering) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Van Burbach Phone: (336) 323-0092 E-mail: Vburbach(cD_labellapc.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Kirksey Drive 417 Kirksey Drive MSWLF Morganton, NC 12-01 .0500 March 21, 2023 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑ Detection Monitoring of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data Surface water monitoring data ❑ ❑ Assessment Monitoring Methane gas monitoring data Corrective action data (specify) Other(specify) ❑ Corrective Action Notification attached? E No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, 1 have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. G. Van Ness Burbach, Ph,D., P.G. Technical Consultant (336) 323-0092 Facility Reyfesentove Name (Printl Title (Area Code) Telephone Number Signature 12 D Oak Branch Dr, Greensboro, NC 27407 Facility Representative Address C-0782 NC PE Firm License Number (if applicable effective May 1, 2009) Affix NC Licensed/ Professional Geologist Seal SEAL 1349 9 �FO� 0G�`'� P LaBella Powered by partnership. March 28, 2023 Mark Delehant General Services Director Burke County P.O. Box 1486 Morganton, NC 28680 RE: Burke County, Kirksey Drive Landfill Permit Number 12-01 Landfill Gas Monitoring Report - 2023 First Quarter Project 2223529, Phase 04 Dear Mark: LaBella Associates (LaBella) is submitting the attached methane monitoring results for Kirksey Drive Landfill, Permit Number 12-01. The 2023 first quarter landfill gas monitoring event was performed on March 21, 2023. During this event, LaBella monitored gas probes GP-1, GP-2, GP-3, GP-4, GP-5 and GP-6, as well as the animal shelter and SPCA buildings (Friends for Animals). The approximate locations of the monitoring locations are depicted in Drawing 1. The monitoring data for the gas probes and buildings are summarized in the attached Landfill Gas Monitoring Data Log. Methane was detected above the lower explosive limit (LEL) in gas probes GP-3 (46.6%), GP-4 (51.2%), and GP-6 (59.4%), and below the LEL in gas probes, GP-1(0.1%) and GP-5 (0.1%). The exceedances are consistent with previous results. Methane detections and LEL exceedances are summarized in the attached Table 1 and Table 2, respectively. We have included a NCDEQ Environmental Monitoring Report Form (EMRF) and will forward a copy of this report to Jaclynne Drummond with the NCDEQ Solid Waste Section. A copy of this report should be maintained in the facility's records. The next quarterly monitoring event is scheduled for the second quarter of 2023. If we can provide any additional information, please do not hesitate to call me at (336) 323-0092. Respectfully submitted, LaBella Associates Van Burbach, PhD, PG Sr. Technical Consultant Attachments: Environmental Monitoring Reporting Form Detection and Exceedance Tables Landfill Gas Monitoring Log Drawing 1 - LFG Monitoring Locations Map cc: Jaclynne Drummond, NCDEQ David Ingram, Burke County 12-D Oak Branch Drive Greensboro, NC 27407 p (336) 323-0092 www.LabeLLapc.com Burke Co. - Kirksey Dr. Landfill Permit # 12-01 Table 1: Methane Detections - March 21, 2023 LFG Probe CH4 (%Vol.) CH4 (%LEL) GP-1 0.1 2 G P-3 46.6 932 G P-4 51.2 1024 G P-5 0.1 2 G P-6 1 59.4 1 1188 11 Table 2: Methane Exceedances - March 21, 2023 LFG CH4 CH4 Probe (%Vol.) (%LEL) G P-3 46.6 932 G P-4 51.2 1024 G P-6 59.4 1188 Notes: CH4 = Methane. %Vol. = Concentration in percent -by -volume. %LEL = Concentration as a percent of the LEL. LEL = Lower Explosive Limit = 5%Vol. Burke Co., Kirksey Dr. Landfill Permit # 12-01 LaBella Associates NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 131-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: k►RKSj_Y Da. t-hr4t VIL-L — g,daV-F c o. Permit Number: '7-- 0i Sampling Date: 3 V Z t I L0 z 3 NC Landfill Rule (.0500 or .1600): ' 0 5 0O Sample Collector Name & Position: t J v . �� ,. a Tj,- ,4 N t -L t A nt Gas Meter Type & Serial Number: (n �N S 0ov S.I k.,50s 1 H9 Gas Meter Calibration Date: 01-1 ©Z� Field Calibration Date & Time: 3 f 2O L013 (D 1 UZ0 Field Calibration Gas Type (15/15 or 5/50 :3s> t0: �o'I.Criy Field Calibration Gas Canister Expiration Date: slts/z0219 Gas Meter Pump Rate: .3 00 m Ljr,-6 v, Ambient Air Temperature:AN Barometric Pressure ®or mmHg): Z9 AU Weather Conditions: C.t-E Ae- Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H1S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 (volume) ) % 02 (volume) % CO2 (volume) % H2S* (yAlusio NOTES 1343 30 0 L 0.1 iij.0 3.4 0.0 30 007 0.0 1.0 1 0.0 i119-3 1339 30 0 C13L 0.3 2fa. 0.0 V-N y 1335 O ej 10214 5k•L ®•� ifol. 84 (AP-5 `-j 132o 30 0 2 0.1 ,s -4.4 o .o u? U 1315 1 30 0 11 bs 5q.L1 0.3 Lio. 3 O . D 5++ ,C Tf,ZZ Li l 3 Z s 3o 0 d. 0 7-1. 0 0.1 0.0 Fa��t�s 15 133L 3o 0 0,0 2.k.Z 0. ► 0.0 NOTE: lfneeded, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. 61. CIE A TITLE CSC. �� �� 2,1Zq 12 D 23 Revised — March 6, 2017 NOTES: 1. CONTOURS OUTSIDE OF THE LANDFILL BOUNDARY WERE DIGITIZED FROM THE MORGANTON NORTH USGS 7 1/2' QUADRANGLE MAP. 2. CONTOURS WITHIN THE SITE WERE DIGITIZED FROM CITY OF MORGANTON TOPOGRAPHY. 3. MONITORING WELL LOCATIONS AND GAS PROBE LOCATIONS WERE SURVEYED MAY 30, 2016. LEGEND EXISTING 20' TOPOGRAPHIC CONTOUR 1120 PROPERTY LINE - - ROAD APPROXIMATE LIMITS OF WASTE STREAM GROUNDWATER MONITORING WELL LOCATION - MW-1 SURFACE MONITORING POINT LOCATION O SMP-1 GAS MONITORING PROBE LOCATION GP-4 PROPOSED GAS VENT LOCATION 0 GV-2 GRAPHIC SCALE 0 150 300 600 (FEET) 2211 W. MEADOW VI EW ROAD GREENSBORO, NC 27407 PHONE: (336) 323-0092 labellapc.com T _ 1 J T _ 1 J 2021 LaBella Associates KIRKSEY DRIVE LANDFILL MANAGEMENT FACILITY Burke County, North Carolina NO DATE DESCRIFION. Re b- PROJECTNUMBER: 2202300.00 DRAWN BY: RH REVIEWED BY RM ISSUED FOR: PERMIT DATE: 06/7/21 DRAWING NAME LANDFILL GAS MONITORING PLAN DRAWING NUMBER'. 1