UST Closure Report
BlueLinx
3300 Parkside Drive
Charlotte, North Carolina 28208
February 7, 2023
Prepared For:
BlueLinx Corporation
1950 Spectrum Circle, Suite 300
Marietta, Georgia 30067
Prepared By:
TRC Environmental Corporation
TRC Engineers, Inc.
9735 Northcross Center Court, Suite N
Huntersville, NC 28078
Project Number: 501850.0000.0000
Elliot J. Nightingale, P.G.
Senior Consultant
Douglas Romer
National Account Manager
Dale M. Allison
National Market Director
BlueLinx, Charlotte, NC February 7, 2023
i
TABLE OF CONTENTS
1.0 SITE INFORMATION ......................................................................................................1
2.0 EXECUTIVE SUMMARY .................................................................................................3
3.0 SITE HISTORY AND CHARACTERIZATION .................................................................4
4.0 CLOSURE PROCEDURE AND SAMPLING ASSESSMENT ..........................................5
5.0 SUMMARY ......................................................................................................................9
6.0 LIMITATIONS ............................................................................................................... 10
TABLES
Table 1: PID Results from Soil Samples
Table 2: Soil Analytical Results from Closure Samples
FIGURES
Figure 1: Site Location Map
Figure 2: Site Layout Map
Figure 3: Sampling Location Map
APPENDICES
Appendix A: Notification of Intent for Closure: UST-3 Form
Appendix B: Site Investigation Report for Closure: UST-2 Form
Appendix C: Laboratory Analytical Reports
Appendix D: Certificate of Liquid and UST Disposal, Fire Department Permit
BlueLinx, Charlotte, NC February 7, 2023
1
1.0 Site Information
Site Identification
Date of Report: February 7, 2023
Site Risk: Low
Facility ID: 00-00-0000014640
UST Incident (if known): NA
Site Name: Bluelinx Corporation
Site Address: 3300 Parkside Drive, Charlotte, North Carolina 28208
County: Mecklenburg
Description of Geographical Data Point: Center of UST Basin
Location Method: NCDEQ Regulatory Compliance Documentation
Latitude / Longitude (decimal degrees): 35.247288, -80.880656
Contact Information:
UST Owner: BlueLinx Corporation, 1950 Spectrum Circle, Suite 300, Marietta, Georgia 30067
UST Owner Contact Information: Michelle Prentice, 770-953-7000,
michelle.prentice@bluelinxco.com
UST Operator: Bluelinx Corporation, 3300 Parkside Drive, Charlotte, North Carolina
UST Operator Contact Information: Reginald Anthony, 704-394-3172
Property Owner: BlueLinx Corporation, 1950 Spectrum Circle, Suite 300, Marietta, Georgia 30067
Property Occupant: Bluelinx Corporation, 3300 Parkside Drive, Charlotte, North Carolina
Consultant / Contractor: Consultant: TRC Engineers, Inc. 9735 Northcross Center Court, Suite N,
Huntersville, North Carolina. 704-621-8360. Contractor: CCI Environmental Services
(CCI), 708 Martin Luther King Jr. Drive, Thomasville, North Carolina, 704-273-1500.
Analytical Laboratory: Waypoint Analytical Laboratory, 449 Springbrook Road, Charlotte, North
Carolina, State Certification 402.
Information Regarding Release:
Date Discovered: No petroleum hydrocarbon release was identified.
Estimated Quantity: NA
Cause of Release: NA
Source of Release: NA
Size and Contents of UST: 10,000-gallon diesel fuel.
BlueLinx, Charlotte, NC February 7, 2023
2
Report Certification:
Certification (The title page must display the seal and signature of the certifying P.E. or L.G., and
the name and certification number of the company or corporation, if applicable [See 15A NCAC
2L .0103(e)].)
I, Elliot J. Nightingale (PG#1165) , a Professional Engineer/Licensed Geologist
(circle one) for TRC Engineers, Inc. , do certify that the information contained in this
report is correct and accurate to the best of my knowledge.
(Please Affix Seal and Signature)
TRC Engineers, Inc. is licensed to practice geology/engineering (circle one or both) in North
Carolina. The certification number of the company or corporation is: C446.
BlueLinx, Charlotte, NC February 7, 2023
3
2.0 Executive Summary
A 10,000 gallon diesel fuel UST was closed by removal at the Bluelinx Corporation warehouse
and transportation facility located at 3300 Parkside Drive, Charlotte, North Carolina. This UST
was installed on September 15, 1992 and replaced an earlier 10,000-gallon diesel fuel UST
located in the same basin.
The closed 10,000-gallon UST was removed from the tank basin on November 29, 2022. The
UST was of double-wall fiberglass reinforced plastic (FRP) construction and measured
approximately 31 feet long by 7.5 feet in diameter. Product and vent lines were of FRP
construction and connected to a single product dispenser pump.
Approximately 288 gallons of residual diesel fuel and wash-water from emptying and cleaning
the tank prior to removal was disposed by CCI Environmental Services (CCI) at their facility in
Thomasville, North Carolina. The product lines were also drained, flushed, and capped by CCI,
as the product lines will remain in the ground. The product dispenser is also remaining in place
as it will be used for the replacement UST system. The former UST was crushed and disposed
by CCI at the Davidson County Landfill in Lexington, North Carolina.
Soil samples obtained from beneath the former UST, beneath the product and vent lines, and
from the overburden soil removed from the basin, were analyzed at the laboratory for TPH-GRO
and TPH-DRO in accordance with DEQ Guidelines for the closure of USTs. None of the soil
samples obtained identified detections of TPH-GRO or TPH-DRO, with the exception of the two
soil samples beneath the product and vent lines which had estimated TPH-DRO of less-than 10
mg/kg.
Following the removal of the former UST, overburden soil was returned to the former UST basin
and compacted, and gravel was used to fill the basin to grade. Following the addition of the
gravel, a rebar reinforced concrete cover was added for site restoration.
Based on the laboratory analytical results and visual observations, TRC has not identified a
release of petroleum hydrocarbons associated with this UST closure and recommends no
further action.
BlueLinx, Charlotte, NC February 7, 2023
4
3.0 Site History and Characterization
According to the UST Database maintained by the North Carolina Department of Environmental
Quality (DEQ), a 10,000-gallon diesel fuel tank was initially installed at the UST basin location
on March 4, 1971. This UST was closed by removal on September 12, 1992. The tank owner
and operator was listed as Georgia Pacific. According to records reviewed by TRC, petroleum
soil contamination was identified at the time of closure, and the soil was excavated from the
basin at the time of the tank removal. The petroleum contaminated soil was disposed, and a
letter dated October 1, 1992 from the North Carolina Department of Environmental Health and
Natural Resources (DEHNR) provided regulatory confirmation that the petroleum soil
contamination was removed from the site and disposed.
The UST Database lists the current 10,000-gallon diesel fuel tank as being installed on
September 15, 1992. This UST was closed by removal on November 29, 2022. There were no
reported releases from this UST or ancillary product or vent lines.
The UST owner and operator are provided in Section 1.0 of this report. The closed tank was
located at the BlueLinx Corporation warehouse facility located at 3300 Parkside Drive in
Charlotte, Mecklenburg County, North Carolina (Figure 1).
The closed 10,000-gallon UST was removed from the tank basin on November 29, 2022. The
UST was of double-wall FRP construction and measured approximately 31 feet long by 7.5 feet
in diameter. Product and vent lines were of FRP construction and connected to a single product
dispenser pump. Soil samples were obtained from the base of the UST and from the
overburden soil pile at the time of closure on November 29, 2022, and no petroleum
hydrocarbon contamination was identified. Soil samples were obtained along the product and
vent lines on December 12, 2022, and no petroleum hydrocarbon contamination was identified.
The location of the former UST system is presented on Figure 2.
BlueLinx, Charlotte, NC February 7, 2023
5
4.0 Closure Procedure and Sampling Assessment
Closure Procedure
Prior to the removal of the UST, the UST-3 Notice of Intent: UST Permanent Closure Form was
submitted to the DEQ on October 27, 2022 (Appendix A). The Charlotte Fire Marshal was
notified in advance of the tank closure scheduled for November 29, 2022. A public utility
notification through the NC-ONE notification system was made so that utilities could mark-out
the locations of subsurface utilities along right-of-way areas.
The UST closure by removal on November 29, 2022, was observed by TRC. The tank removal
was performed by CCI. Prior to removal, TRC retained the services of Integrated Scanning
Solutions (ISS), a private subsurface utility locating firm, to verify the locations of the UST,
product and vent lines, and subsurface utilities in the vicinity of the tank basin.
On November 28, 2022, the day prior to the removal of the UST, CCI verified that electricity was
safely locked out of the UST system. The UST was then checked for contents and CCI
determined that there was a small quantity of diesel fuel in the tank. The contents of the tank
were removed through a pump truck provided by CCI. The interior of the tank was then pressure
washed to remove residual sludge. The wash water was contained and stored in a truck-
mounted vessel for disposal. The total amount of liquid removed from the UST, including the
diesel fuel and wash water, was 288 gallons. The concrete surface above the tank basin was
cut using a concrete saw.
On November 29, 2022, the concrete cover above the UST was removed and placed at an area
beside the tank basin on a layer of Visqueen polyethylene plastic. A track hoe was used to
remove overburden soil above the tank and soil surrounding the tank and placed on the plastic
cover. Once the product line and vent line were fully exposed in the basin, the two lines were
cut and sealed as these lines were not scheduled to be removed with the UST. The Charlotte,
North Carolina Fire Marshal inspected the UST prior to removal and performed a vapor test
inside of the vessel and determined that vapors inside of the tank were below the lower
explosive limit and safe to remove. The remaining overburden soil was then removed from the
basin by CCI.
Once a sufficient amount of soil had been removed, the UST was removed from the tank basin
and loaded on to a flatbed truck using a trackhoe. The top of the tank was approximately two-
feet below the concrete surface. The UST measured approximately 31 feet in length and 7.5
feet in diameter. Four soil samples were obtained beneath the former tank location in native soil
approximately 9.5 feet below the ground surface from the bucket of the trackhoe. Additionally,
two soil samples were obtained approximately 2 feet below the product line and 2 feet below the
BlueLinx, Charlotte, NC February 7, 2023
6
vent line, exposed at the southwest extent of the basin. Two composite soil samples were
obtained from the stockpiled soil using a hand auger.
The final dimensions of the former UST basin excavation were approximately: 35 feet in the
northwest-southeast direction (length); 8 feet in the northeast-southwest dimension; and 9 feet
in depth.
The soil encountered was brown silty clay to a depth of approximately 9 feet below ground
surface (ft bgs). The soil encountered between 9 ft bgs and 9.5 ft bgs was silty sandy clay
saprolite with relict textures representative of the weakly foliated granitic bedrock in this area.
There was no groundwater encountered in the former tank basin. The soil sample locations are
illustrated on Figure 3.
The soil samples from beneath the former UST, the distribution lines, and composite samples
from the soil stockpile were screened in the field using a photoionization detector (PID) to
determine the presence of volatile organic compounds (VOCs). The PID readings ranged from
non-detect to a maximum of 1.9 parts-per-million (ppm) and are presented on Table 1.
Following the PID screening for each soil sample, the soil samples were placed in laboratory-
supplied containers and a pre-chilled cooler provided by Waypoint Analytical Laboratory of
Charlotte, North Carolina. The chain-of-custody was completed and each of the eight soil
samples designated for analysis for Total Petroleum Hydrocarbons (TPH) Gasoline Range
Organics (GRO) and Diesel Range Organics (DRO) in accordance with DEQ Guidelines.
Following the completion of the field sampling in the former tank basin, TRC determined that
based on the field observations and PID scanning results, the excavated soil could be returned
to the former tank basin. The excavated soil was then returned to the tank basin by CCI and
compacted. Following the soil compaction, CCI provided graded aggregate base gravel (crusher
run) to be placed on top of the soil in the former basin. The gravel base was added to the former
basin to grade.
On December 12, 2022, a drill rig using Direct Push Technology (DPT) was used to advance
two shallow soil borings through the concrete in the vicinity of the product line run from the
dispenser pump to the former UST basin. Due to the continued use of the subject property, and
truck traffic in this part of the property, it was not practical to remove the product lines.
Therefore, the product lines remain as abandoned in-place with the two soil samples providing
data for their closure. The approximate length of product line was 17 feet from the dispenser
pump to the edge of the tank basin, therefore, two soil samples were obtained: one near the
product dispenser and the one near the center of the product line run. This line sampling
augmented the samples obtained at the time of the tank removal from within the UST basin. The
BlueLinx, Charlotte, NC February 7, 2023
7
product lines were measured to be approximately 2 feet below the concrete, and the samples
were obtained at 2.5 feet below the concrete, or, 0.5 feet below the lines. The two soil samples
were analyzed at Waypoint Analytical Laboratory for TPH GRO and TPH DRO. The location of
the line samples are illustrated on Figure 3.
Both the product line and vent line extend from the dispenser pump to the former UST basin
with a gentle slop towards the basin. The depth of these lines are approximately 2 ft bgs below
the concrete at the dispenser pump and approximately 2.5 ft bgs below the concrete at the
former UST basin. The purpose of this downward slope is based on the design of the former
UST system utilizing a European Suction System where product returns through the line to the
tank when not being pumped.
Sampling Assessment
The laboratory analytical results from the soil sampling from below the UST, the product lines,
and the soil pile were all below the DEQ criteria for TPH GRO and TPH DRO. The soil sampling
results are summarized below and presented in Table 2. The sampling locations are illustrated
on Figure 3, the DEQ Site Investigation Report for Closure (UST-2 Form) is provided in
Appendix B, and the laboratory report is provided in Appendix C.
Soil Pile:
SP-1: DRO: <5.33, GRO: <2.37
SP-2: DRO: <5.15, GRO: <2.29
Beneath the UST:
S-1-9: DRO: <5.47, GRO: <2.44
S-2-9: DRO: <5.38, GRO: <2.40
S-3-9: DRO: <5.62, GRO: <2.50
S-4-9: DRO: <5.52, GRO: <2.46
PL-1: DRO: <5.93, GRO: <2.64
PL-2: DRO: <5.68, GRO: <2.53
Beneath the Lines:
PL-1A: DRO: 7.17J, GRO: <2.73
PL-2A: DRO: 9.71J, GRO: <2.46
Results in mg/kg; J denotes estimated concentration.
Liquid and UST Disposal / Site Restoration
The residual diesel fuel and wash-water contents from the tank were transported by CCI for
disposal at their licensed waste disposal facility in Thomasville, North Carolina. According to the
non-hazardous waste manifest, the total quantity of diesel fuel and wash-water disposed was
288 gallons.
BlueLinx, Charlotte, NC February 7, 2023
8
The former UST was transported by CCI for disposal at the Davidson County Landfill in
Lexington, North Carolina. According to the non-hazardous waste manifest, one empty (and
crushed) 10,000 fiberglass UST, weighing approximately 11,420 pounds, was disposed. The
manifests are provided in Appendix D.
On December 30, 2022, CCI’s contractor, Petrishen Concrete, LLC of Mocksville, North
Carolina, completed the site restoration by providing a concrete cover over the former UST
basin.
BlueLinx, Charlotte, NC February 7, 2023
9
5.0 Summary
On November 29, 2022, the 10,000-gallon diesel fuel UST was closed by removal. The ancillary
product line and vent line were capped and abandoned in-place. Overburden soil that was
removed from the former tank basin was returned to the basin following the removal of the tank.
Soil samples obtained from beneath the former UST and beneath the product line and vent line
were analyzed at the laboratory for TPH-GRO and TPH-DRO in accordance with DEQ
Guidelines for the closure of USTs. None of the soil samples obtained identified detections of
TPH-GRO or TPH-DRO, with the exception of the two soil samples beneath the product and
vent lines which had estimated TPH-DRO of less-than 10 mg/kg.
Based on the laboratory analytical results and visual observations, TRC has not identified a
release of petroleum hydrocarbons associated with this UST closure and recommends no
further action.
BlueLinx, Charlotte, NC February 7, 2023
10
6.0 Limitations
The work performed in conjunction with this assessment, and the data developed, are intended
as a description of available information at the dates and locations given. This report does not
warrant against future operations or conditions, nor does it warrant against operations or
conditions present of a type, or at a location not assessed, nor against future operations or
conditions. The present assessment includes the sampling of soil at the subject property. The
conclusions drawn from this assessment are considered reliable; however, there may exist
localized variations in subsurface conditions that have not been completely defined at this time.
Our professional services have been performed, our findings obtained, and our
recommendations prepared in accordance with customary principles and practices in the fields
of environmental science and engineering. This warranty is in lieu of all other warranties either
expressed or implied. TRC is not responsible for the independent conclusions, opinions, or
recommendations made by others based on the results and designs presented in this report.
The passage of time may result in a change in the environmental characteristics at the subject
property and surrounding properties. This report does not warrant against future operations or
conditions, nor does it warrant operations or conditions present of a type or at a location not
assessed. It must be noted that no environmental assessment can absolutely rule out the
existence of any hazardous substances at a given property. If a higher level of confidence is
required than can be defined by this scope of work, then additional assessment may be
required.
Tables
Sample
Identification
Sample Depth
(feet)Date Collected Sample Location
Area PID (ppm)
SP-1 composite 11/29/2022 Soil Pile ND
SP-2 composite 11/29/2022 Soil Pile ND
S-1-9 9 11/29/2022 UST Basin ND
S-2-9 9 11/29/2022 UST Basin ND
S-3-9 9 11/29/2022 UST Basin ND
S-4-9 9 11/29/2022 UST Basin 1.2
PL-1 4.5 11/29/2022 Product Line 0.2
PL-2 4.5 11/29/2022 Product Line ND
PL-1A 2.5-3 12/2/2022 Product Line ND
PL-2A 2.5-3 12/2/2022 Product Line ND
Notes:
Concentrations in parts per million (ppm)
PID = Photoionization Detector
ND = Not Detected
Charlotte, North Carolina 28208
TABLE 1
(PID) RESULTS, UST CLOSURE
PHOTOIONIZATION DETECTOR
Bluelinx
3300 Parkside Drive
TABLE 2
SOIL ANALYTICAL RESULTS FROM UST CLOSURE
TPH-GROTPH-DROSP-1 composite 11/29/2022 Soil Pile < 2.37 < 5.33
SP-2 composite 11/29/2022 Soil Pile < 2.29 < 5.15
S-1-9 9 11/29/2022 UST Basin < 2.44 < 5.47
S-2-9 9 11/29/2022 UST Basin < 2.40 < 5.38
S-3-9 9 11/29/2022 UST Basin < 2.50 < 5.62
S-4-9 9 11/29/2022 UST Basin < 2.46 < 5.52
PL-1 4.5 11/29/2022 Product Line < 2.64 < 5.93
PL-2 4.5 11/29/2022 Product Line < 2.53 < 5.68
PL-1A 2.5-3 12/2/2022 Product Line < 2.73 7.17 J
PL-2A 2.5-3 12/2/2022 Product Line < 2.46 9.71 J
50 100
Notes:
Concentrations in mg/kg
J Denotes estimated value between method detection limit and reporting limit
NCDEQ = North Carolina Department of Environmental Quality
NCDEQ - UST Section - Preliminary Assessment Guideline
Date Collected
Bluelinx
3300 Parkside Drive
Charlotte, North Carolina 28208
Sample
Identification
Sample Depth (feet
bgs)
Sample Location
Area
TPH - Total Petroleum
Hydrocarbons
Figures
NOTESFIGURE 1 –BLUELINX
SITE LOCATION FIGURE
BLUELINX WAREHOUSE SITE3300 PARKSIDE DRIVE
CHARLOTTE, NORTH CAROLINA 28208
Drawn by: EJN Date: 11/15/2022
TRC Project No.: 501850.0000.0000 Figure: 29735 Northcross Center Court, Suite NHuntersville, North Carolina 28078
Source: USGS NationalMap Viewer, Scale is Approximate
0 550 1,100
ONE INCH = APPROXIMATELY 550 FEET
SCALE
SUBJECT PROPERTY
NOTESFIGURE 2 –BLUELINX
SITE LAYOUT
BLUELINX WAREHOUSE SITE
3300 PARKSIDE DRIVE
CHARLOTTE, NORTH CAROLINA 28208
Drawn by: EJN Date: 11/15/2022
TRC Project No.: 501850.0000.0000 Figure: 29735 Northcross Center Court, Suite N
Huntersville, North Carolina 28078 Source: Google Maps
Scale and Property Boundaries
are Approximate
0 160 320
ONE INCH = APPROXIMATELY 160 FEET
SCALE
UST BASIN AND
DISPENSER ISLAND
NOTESFIGURE 3 –BLUELINX
SOIL SAMPLE LOCATIONS
BLUELINX WAREHOUSE SITE
3300 PARKSIDE DRIVE
CHARLOTTE, NORTH CAROLINA 28208
Drawn by: EJN Date: 1/6/2023
TRC Project No.: 501850.0000.0000 Figure: 39735 Northcross Center Court, Suite N
Huntersville, North Carolina 28078 Source: Google Earth
Scale and Feature Boundaries
are Approximate
0 7 14
ONE INCH = APPROXIMATELY 7 FEET
SCALE
DIESEL FUEL
DISPENSER PUMP
PRODUCT AND VENT
LINES
APPROXIMATE LIMITS
OF UST BASIN
AREA OF TEMPORARY
SOIL PILE ON PLASTIC
S-1-9
S-2-9
S-3-9
S-4-9
PL-1
PL-2
PL-1A
PL-2A
SOIL SAMPLE
EXPLANATION
Appendix A: Notification of Intent for Closure: UST-3 Form
Appendix B: Site Investigation Report for Closure: UST-2 Form
UST-2A Site Investigation Report for Permanent Closure or Change-in-
Service of
REGISTERED UST
Return completed form to:
NC DEQ / DWM / UST SECTION
1646 MAIL SERVICE CENTER
RALEIGH, NC 27699-1646
ATTN: REGISTRATION & PERMITTING
phone (919) 707-8171 fax (919) 715-1117 http://www.wastenotnc.org/
STATE USE ONLY:
Facility ID #
Date Received
INSTRUCTIONS (READ THIS FIRST)
1. UST permanent closure or change in service must be completed in accordance with the latest version of the Guidelines for Site Checks, Tank
Closure and Initial Response and Abatement. The guidelines can be obtained at http://deq.nc.gov/about/divisions/waste-management/waste-
management-permit-guidance/underground-storage-tanks-section.
2. Permanent closure: Complete all sections of this form.
3. Change-in-service: Where a UST system will be converted from storing a regulated substance to a non-regulated substance, complete sections I, II,
III, IV, and VI
4. For more than 5 registered UST systems, attach additional forms as needed
5. Tank Fee Refund: An annual tank fee may be refunded for a tank for which a tank fee was not required. An owner or operator must submit
a written request and include: (1) contact information, (2) federal identification # or SSN, and (3) a copy of UST-2 form. The annual tank
fee will be prorated based on the date of permanent closure.
6. UNREGISTERED USTs use Form UST-2B
I. OWNERSHIP OF TANKS II. LOCATION OF TANKS
Owner Name (Corporation, Individual, Public Agency, or Other Entity)
Bluelinx Corporation
Facility Name or Company
Bluelinx Corporation
Street Address
1950 Spectrum Circle, Suite 300
Facility ID # (If known)
00-00-0000014640
City
Marietta
County Street Address
3300 Parkside Drive
State
GA
Zip Code
30067
City
Charlotte
County
Meck
Zip Code
28208
Phone Number
770-221-2735
Phone Number
704-394-3172
III. CONTACT PERSONNEL
Contact for Facility:
Reginald Anthony
Job Title:
Manager
Phone #:
704-394-3172
Closure Contractor Name:
Jason Jomp
Closure Contractor Company:
CCI Environmental Services
Address:
Thomasville
Phone #
704-273-1500
Primary Consultant Name:
E. Nightingale
Primary Consultant Company:
TRC Engineers, Inc.
Address:
Charlotte
Phone #
704-621-8360
IV. UST INFORMATION FOR REGISTERED UST SYSTEMS
UNREGISTERED USTs use Form UST-2B
V. EXCAVATION CONDITION
Tank ID
No.
Size in
Gallons
Last
Contents
Last
Use
Date
Permanent
Close Date
Method of Permanent Closure:
Indicate REMOVED or enter fill
material, such as foam/
concrete/ sand
Change-in-
Service
Date
Water in
excavation Free product
Notable
odor or
visible soil
contaminatio
n
Yes No Yes No Yes No
1A 10000 Other Non Petroleum2022 11/28/22 REMOVED 10/27/22
VI. CERTIFICATION
I certify under penalty of law that I have personally examined and am familiar with the information submitted in this and all attached documents and that
based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the submitted information is true accurate
and complete.
Print name and official title of owner or owner’s authorized
representative
Signature Date Signed
NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY, DIVISION OF WASTE MANAGEMENT, UST SECTION
1646 MAIL SERVICE CENTER, RALEIGH, NC 27699-1646 PHONE (919) 707-8171 FAX (919) 715-1117 http://www.wastenotnc.org/ 1/2016
DocuSign Envelope ID: C82B0A3B-941C-4140-9EBA-1733EF0C79FE
Josh Teteak
2/6/2023
Appendix C: Laboratory Analytical Reports
Laboratory's liability in any claim relating to analyses performed shall be limited to, at laboratory's option, repeating the
analysis in question at laboratory's expense, or the refund of the charges paid for performance of said analysis.
12/1/2022
TRC Environmental Corporation Elliot Nightingale
9735 Northcross Center Court, Suite N
Huntersville, NC, 28078
Ref: Analytical Testing Lab Report Number: 22-333-0005
Client Project Description: Bluelinx UST
Dear Elliot Nightingale:
Waypoint Analytical, LLC (Charlotte) received sample(s) on 11/29/2022 for the analyses presented in the following report.
The above referenced project has been analyzed per your instructions. The analyses were performed in
accordance with the applicable analytical method.
The analytical data has been validated using standard quality control measures performed as required by the analytical method. Quality Assurance, method validations, instrumentation maintenance and calibration for all
parameters were performed in accordance with guidelines established by the USEPA (including 40 CFR 136 Method Update Rule May 2021) unless otherwise indicated. Certain parameters (chlorine, pH, dissolved oxygen, sulfite...) are required to be analyzed within 15 minutes of
sampling. Usually, but not always, any field parameter analyzed at the laboratory is outside of this holding time. Refer to sample analysis time for confirmation of holding time compliance.
The results are shown on the attached Report of Analysis(s). Results for solid matrices are reported on an as-
received basis unless otherwise indicated. This report shall not be reproduced except in full and relates only to the samples included in this report. Please do not hesitate to contact me or client services if you have any questions or need additional information.
Sincerely,
Angela D Overcash Senior Project Manager
Page 1 of 26
Certification Summary
Laboratory ID: WP CNC: Waypoint Analytical Carolina, Inc. (C), Charlotte, NC
State Program Lab ID Expiration Date
07/31/202337735State ProgramNorth Carolina
12/31/2022402State ProgramNorth Carolina
07/31/202399012State ProgramSouth Carolina
12/31/202299012State ProgramSouth Carolina
Page 1 of 1 00016/22-333-0005
Page 2 of 26
Report Number:
Sample Summary Table
Client Project Description:
22-333-0005
Bluelinx UST
Lab No Client Sample ID Matrix Date Collected Date Received
11/29/2022 09:25Solids 94265 SP-1 11/29/2022 11:30
11/29/2022 09:30Solids 94266 SP-2 11/29/2022 11:30
11/29/2022 09:35Solids 94267 S-1 9'11/29/2022 11:30
11/29/2022 09:40Solids 94268 S-2 9'11/29/2022 11:30
11/29/2022 09:45Solids 94269 S-3 9'11/29/2022 11:30
11/29/2022 09:50Solids 94270 S-4 9'11/29/2022 11:30
11/29/2022 09:55Solids 94271 PL-1 4.5'11/29/2022 11:30
11/29/2022 10:00Solids 94272 PL-2 4.5'11/29/2022 11:30
Page 3 of 26
Summary of Detected Analytes
QualifiersAnalyzedUnitsResult
Report Number:
Client Sample ID
Method Parameters
Lab Sample ID
22-333-0005
Report Limit
Project:Bluelinx UST
V 94265SP-1
12.8 11/29/2022 16:36SW-DRYWT Moisture %
V 94266SP-2
9.76 11/29/2022 16:36SW-DRYWT Moisture %
V 94267S-1 9'
15.0 11/29/2022 16:36SW-DRYWT Moisture %
V 94268S-2 9'
13.6 11/29/2022 16:36SW-DRYWT Moisture %
V 94269S-3 9'
17.2 11/29/2022 16:36SW-DRYWT Moisture %
V 94270S-4 9'
15.7 11/29/2022 16:36SW-DRYWT Moisture %
V 94271PL-1 4.5'
21.6 11/29/2022 16:36SW-DRYWT Moisture %
V 94272PL-2 4.5'
18.1 11/29/2022 16:36SW-DRYWT Moisture %
Page 4 of 26
Client: TRC Environmental Corporation CASE NARRATIVE
Project: Bluelinx UST Lab Report Number: 22-333-0005
Date: 12/1/2022
Total Petroleum Hydrocarbons - Extractable Method 8015C DRO QC Batch No: V27119/V27062 Recovery for the LCS exceeded the upper acceptance limit. However, all sample results associated with the
batch are below the MQL, so this high bias had no impact upon the client data. The results are considered to be acceptable.
Total Petroleum Hydrocarbons - Volatile Method 8015C GRO
Sample 94271 (PL-1 4.5') Analyte: a,a,a-Trifluorotoluene
QC Batch No: V27090/V27089 Surrogate(s) exhibited a high bias in this project sample where no target analytes were detected. The high
recovery(s) had no impact on the data. Batch QC samples (method blank and laboratory control samples) all showed surrogates within QC limits.
Page 5 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:SP-1
94265 Matrix:
11/29/2022 9:25
Solids
Test Results Units MDL MQL By Analytical
Method
Date / Time
Analyzed
DF
12.8 %Moisture 1 11/29/22 16:36 SW-DRYWTAMB
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 6 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:SP-1
94265 Matrix:
11/29/2022 9:25
Solids
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
3546
8015C DRO Prep Batch(es):V27062 11/30/22 11:10
<5.33 mg/Kg - dry 5.33 11.5Diesel Range Organics (C10-C28)1 12/01/22 10:35 V27119AMP
8015C DROSurrogate: OTP Surrogate 87.2 Limits: 31-123%12/01/22 10:351 AMP
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
5035 MED
8015C GRO Prep Batch(es):V27089 11/29/22 08:00
<2.37 mg/Kg - dry 2.37 5.73Gasoline Range Organics (C6-C10)50 11/29/22 16:51 V27090TBL
8015C GROSurrogate: a,a,a-Trifluorotoluene 112 Limits: 50-137%11/29/22 16:5150 TBL
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 7 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:SP-2
94266 Matrix:
11/29/2022 9:30
Solids
Test Results Units MDL MQL By Analytical
Method
Date / Time
Analyzed
DF
9.76 %Moisture 1 11/29/22 16:36 SW-DRYWTAMB
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 8 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:SP-2
94266 Matrix:
11/29/2022 9:30
Solids
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
3546
8015C DRO Prep Batch(es):V27062 11/30/22 11:10
<5.15 mg/Kg - dry 5.15 11.1Diesel Range Organics (C10-C28)1 12/01/22 10:56 V27119AMP
8015C DROSurrogate: OTP Surrogate 84.2 Limits: 31-123%12/01/22 10:561 AMP
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
5035 MED
8015C GRO Prep Batch(es):V27089 11/29/22 08:00
<2.29 mg/Kg - dry 2.29 5.54Gasoline Range Organics (C6-C10)50 11/29/22 17:19 V27090TBL
8015C GROSurrogate: a,a,a-Trifluorotoluene 118 Limits: 50-137%11/29/22 17:1950 TBL
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 9 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:S-1 9'
94267 Matrix:
11/29/2022 9:35
Solids
Test Results Units MDL MQL By Analytical
Method
Date / Time
Analyzed
DF
15.0 %Moisture 1 11/29/22 16:36 SW-DRYWTAMB
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 10 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:S-1 9'
94267 Matrix:
11/29/2022 9:35
Solids
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
3546
8015C DRO Prep Batch(es):V27062 11/30/22 11:10
<5.47 mg/Kg - dry 5.47 11.8Diesel Range Organics (C10-C28)1 12/01/22 11:18 V27119AMP
8015C DROSurrogate: OTP Surrogate 86.6 Limits: 31-123%12/01/22 11:181 AMP
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
5035 MED
8015C GRO Prep Batch(es):V27089 11/29/22 08:00
<2.44 mg/Kg - dry 2.44 5.88Gasoline Range Organics (C6-C10)50 11/29/22 17:47 V27090TBL
8015C GROSurrogate: a,a,a-Trifluorotoluene 120 Limits: 50-137%11/29/22 17:4750 TBL
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 11 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:S-2 9'
94268 Matrix:
11/29/2022 9:40
Solids
Test Results Units MDL MQL By Analytical
Method
Date / Time
Analyzed
DF
13.6 %Moisture 1 11/29/22 16:36 SW-DRYWTAMB
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 12 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:S-2 9'
94268 Matrix:
11/29/2022 9:40
Solids
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
3546
8015C DRO Prep Batch(es):V27062 11/30/22 11:10
<5.38 mg/Kg - dry 5.38 11.6Diesel Range Organics (C10-C28)1 12/01/22 11:39 V27119AMP
8015C DROSurrogate: OTP Surrogate 86.5 Limits: 31-123%12/01/22 11:391 AMP
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
5035 MED
8015C GRO Prep Batch(es):V27089 11/29/22 08:00
<2.40 mg/Kg - dry 2.40 5.79Gasoline Range Organics (C6-C10)50 11/29/22 18:16 V27090TBL
8015C GROSurrogate: a,a,a-Trifluorotoluene 123 Limits: 50-137%11/29/22 18:1650 TBL
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 13 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:S-3 9'
94269 Matrix:
11/29/2022 9:45
Solids
Test Results Units MDL MQL By Analytical
Method
Date / Time
Analyzed
DF
17.2 %Moisture 1 11/29/22 16:36 SW-DRYWTAMB
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 14 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:S-3 9'
94269 Matrix:
11/29/2022 9:45
Solids
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
3546
8015C DRO Prep Batch(es):V27062 11/30/22 11:10
<5.62 mg/Kg - dry 5.62 12.1Diesel Range Organics (C10-C28)1 12/01/22 12:00 V27119AMP
8015C DROSurrogate: OTP Surrogate 85.8 Limits: 31-123%12/01/22 12:001 AMP
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
5035 MED
8015C GRO Prep Batch(es):V27089 11/29/22 08:00
<2.50 mg/Kg - dry 2.50 6.04Gasoline Range Organics (C6-C10)50 11/29/22 18:43 V27090TBL
8015C GROSurrogate: a,a,a-Trifluorotoluene 113 Limits: 50-137%11/29/22 18:4350 TBL
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 15 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:S-4 9'
94270 Matrix:
11/29/2022 9:50
Solids
Test Results Units MDL MQL By Analytical
Method
Date / Time
Analyzed
DF
15.7 %Moisture 1 11/29/22 16:36 SW-DRYWTAMB
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 16 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:S-4 9'
94270 Matrix:
11/29/2022 9:50
Solids
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
3546
8015C DRO Prep Batch(es):V27062 11/30/22 11:10
<5.52 mg/Kg - dry 5.52 11.9Diesel Range Organics (C10-C28)1 12/01/22 12:21 V27119AMP
8015C DROSurrogate: OTP Surrogate 86.5 Limits: 31-123%12/01/22 12:211 AMP
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
5035 MED
8015C GRO Prep Batch(es):V27089 11/29/22 08:00
<2.46 mg/Kg - dry 2.46 5.93Gasoline Range Organics (C6-C10)50 11/29/22 19:12 V27090TBL
8015C GROSurrogate: a,a,a-Trifluorotoluene 118 Limits: 50-137%11/29/22 19:1250 TBL
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 17 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:PL-1 4.5'
94271 Matrix:
11/29/2022 9:55
Solids
Test Results Units MDL MQL By Analytical
Method
Date / Time
Analyzed
DF
21.6 %Moisture 1 11/29/22 16:36 SW-DRYWTAMB
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 18 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:PL-1 4.5'
94271 Matrix:
11/29/2022 9:55
Solids
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
3546
8015C DRO Prep Batch(es):V27062 11/30/22 11:10
<5.93 mg/Kg - dry 5.93 12.8Diesel Range Organics (C10-C28)1 12/01/22 12:43 V27119AMP
8015C DROSurrogate: OTP Surrogate 86.5 Limits: 31-123%12/01/22 12:431 AMP
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
5035 MED
8015C GRO Prep Batch(es):V27089 11/29/22 08:00
<2.64 mg/Kg - dry 2.64 6.38Gasoline Range Organics (C6-C10)50 11/29/22 19:40 V27090TBL
8015C GROSurrogate: a,a,a-Trifluorotoluene 139 *Limits: 50-137%11/29/22 19:4050 TBL
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 19 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:PL-2 4.5'
94272 Matrix:
11/29/2022 10:00
Solids
Test Results Units MDL MQL By Analytical
Method
Date / Time
Analyzed
DF
18.1 %Moisture 1 11/29/22 16:36 SW-DRYWTAMB
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 20 of 26
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-333-0005
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Elliot Nightingale
Huntersville
Received : 11/29/2022
Bluelinx UST
Report Date : 12/01/2022
Sample ID :
Lab No :
Sampled:PL-2 4.5'
94272 Matrix:
11/29/2022 10:00
Solids
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
3546
8015C DRO Prep Batch(es):V27062 11/30/22 11:10
<5.68 mg/Kg - dry 5.68 12.2Diesel Range Organics (C10-C28)1 12/01/22 13:04 V27119AMP
8015C DROSurrogate: OTP Surrogate 90.2 Limits: 31-123%12/01/22 13:041 AMP
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
5035 MED
8015C GRO Prep Batch(es):V27089 11/29/22 08:00
<2.53 mg/Kg - dry 2.53 6.11Gasoline Range Organics (C6-C10)50 11/29/22 20:09 V27090TBL
8015C GROSurrogate: a,a,a-Trifluorotoluene 106 Limits: 50-137%11/29/22 20:0950 TBL
Qualifiers/
Definitions
Dilution FactorDFOutside QC Limit*
Method Quantitation LimitMQL
Page 21 of 26
Quality Control Data
22-333-0005Report No:
Project Description:
Client ID:TRC Environmental Corporation
Bluelinx UST
QC Prep Batch Method:
Total Petroleum Hydrocarbons - Extractable
8015C DRO
V27119QC Analytical Batch(es):
Analysis Method:
Analysis Description:
3546
QC Prep:V27062
Associated Lab Samples: 94265, 94266, 94267, 94268, 94269, 94270, 94271, 94272
LRB-V27062 Matrix: SOLLab Reagent Blank
Parameter
AnalyzedMQLMDLBlank
ResultUnits
%
Recovery
% Rec
Limits
12/01/22 09:3110.04.65<4.65mg/KgDiesel Range Organics (C10-C28)
12/01/22 09:31OTP Surrogate (S)89.4 31-123
LCS-V27062 LCSD-V27062Laboratory Control Sample & LCSD
LCSD
ResultParameter Max
RPD
LCSD
% Rec
LCS
%Rec
LCS
Result
Spike
Conc.Units
% Rec
Limits RPD
92.8 139*11174.266.7mg/KgDiesel Range Organics (C10-C28)46-126 22.2*20
89.478.9OTP Surrogate (S)31-123
Page 1 of 3* QC Fail Date:12/01/2022 04:41 PM
Page 22 of 26
Quality Control Data
22-333-0005Report No:
Project Description:
Client ID:TRC Environmental Corporation
Bluelinx UST
QC Prep Batch Method:
Total Petroleum Hydrocarbons - Volatile
8015C GRO
V27090QC Analytical Batch(es):
Analysis Method:
Analysis Description:
5035 MED
QC Prep:V27089
Associated Lab Samples: 94265, 94266, 94267, 94268, 94269, 94270, 94271, 94272
LRB-V27089 Matrix: SOLLab Reagent Blank
Parameter
AnalyzedMQLMDLBlank
ResultUnits
%
Recovery
% Rec
Limits
11/29/22 16:225.002.07<2.07mg/KgGasoline Range Organics (C6-C10)
11/29/22 16:22a,a,a-Trifluorotoluene (S)111 50-137
LCS-V27089Laboratory Control Sample
Parameter
LCS %RecLCS
Result
Spike
Conc.Units
% Rec
Limits
10251.050.0mg/KgGasoline Range Organics (C6-C10)41-138
105a,a,a-Trifluorotoluene (S)50-137
V 94265-MS-V27089 V 94265-MSD-V27089Matrix Spike & Matrix Spike Duplicate
MS Result
Parameter
Max
RPD
MS
%Rec
MSD
Result
MSD
Spike
Conc.
MS Spike
Conc.ResultUnits
%Rec
Limits
MSD
%Rec RPD
50.5 10148.350.050.0<2.07mg/KgGasoline Range Organics (C6-C10)96.6 41-138 4.4 34
118a,a,a-Trifluorotoluene (S)113 50-137
Page 2 of 3Date:12/01/2022 04:41 PM
Page 23 of 26
Quality Control Data
22-333-0005Report No:
Project Description:
Client ID:TRC Environmental Corporation
Bluelinx UST
Dry Weight Determination
SW-DRYWT
V27010QC Analytical Batch:
Analysis Method:
Analysis Description:
V 93640-DUPDuplicate
Max RPD
Parameter
AnalyzedRPDDUP
Result
Result
Units
20.0 11/29/22 16:360.355.755.9%Moisture
V 93645-DUPDuplicate
Max RPD
Parameter
AnalyzedRPDDUP
Result
Result
Units
20.0 11/29/22 16:360.858.457.9%Moisture
Page 3 of 3Date:12/01/2022 04:41 PM
Page 24 of 26
Fed Ex
UPS
US Postal
Client
Lab
Courier
Other :
Shipment Receipt Form
Customer Number:
Customer Name:
Report Number:22-333-0005
TRC Environmental Corporation
00249
Shipping Method
Shipping container/cooler uncompromised?
Thermometer ID:IRT-15 3.7C
Chain of Custody (COC) present?Yes No
Yes No Not Present
Yes No Not Present
Yes No
COC agrees with sample label(s)? Yes No
COC properly completed
Samples in proper containers?
Sample containers intact?
Sufficient sample volume for indicated test(s)?
All samples received within holding time?
Cooler temperature in compliance?
Yes No
Yes No
Yes No
Yes No
Yes No
Yes NoCooler/Samples arrived at the laboratory on ice.
Samples were considered acceptable as cooling
process had begun.
Yes No
Yes No N/A
Yes No N/A
Yes No N/ASoil VOA method 5035 – compliance criteria met
Water - Sample containers properly preserved
Water - VOA vials free of headspace Yes No N/A
Trip Blanks received with VOAs
Low concentration EnCore samplers (48 hr)
High concentration pre-weighed (methanol -14 d) Low conc pre-weighed vials (Sod Bis -14 d)ü
High concentration container (48 hr)
Custody seals intact on shipping container/cooler?
Custody seals intact on sample bottles?
Number of coolers/boxes received
Yes No
1
Signature:Angelo Norvell Date & Time:11/29/2022 11:41:24
Special precautions or instructions included?
Comments:
Page 25 of 26
Page 26 of 26
Laboratory's liability in any claim relating to analyses performed shall be limited to, at laboratory's option, repeating the
analysis in question at laboratory's expense, or the refund of the charges paid for performance of said analysis.
12/21/2022
TRC Environmental Corporation Natalie Stevens
9735 Northcross Center Court, Suite N
Huntersville, NC, 28078
Ref: Analytical Testing Lab Report Number: 22-347-0034
Client Project Description: Bluelnx Charlotte UST
Dear Natalie Stevens:
Waypoint Analytical, LLC (Charlotte) received sample(s) on 12/13/2022 for the analyses presented in the following report.
The above referenced project has been analyzed per your instructions. The analyses were performed in
accordance with the applicable analytical method.
The analytical data has been validated using standard quality control measures performed as required by the analytical method. Quality Assurance, method validations, instrumentation maintenance and calibration for all
parameters were performed in accordance with guidelines established by the USEPA (including 40 CFR 136 Method Update Rule May 2021) unless otherwise indicated. Certain parameters (chlorine, pH, dissolved oxygen, sulfite...) are required to be analyzed within 15 minutes of
sampling. Usually, but not always, any field parameter analyzed at the laboratory is outside of this holding time. Refer to sample analysis time for confirmation of holding time compliance.
The results are shown on the attached Report of Analysis(s). Results for solid matrices are reported on an as-
received basis unless otherwise indicated. This report shall not be reproduced except in full and relates only to the samples included in this report. Please do not hesitate to contact me or client services if you have any questions or need additional information.
Sincerely,
Angela D Overcash Senior Project Manager
Page 1 of 13
Certification Summary
Laboratory ID: WP CNC: Waypoint Analytical Carolina, Inc. (C), Charlotte, NC
State Program Lab ID Expiration Date
07/31/202337735State ProgramNorth Carolina
12/31/2022402State ProgramNorth Carolina
07/31/202399012State ProgramSouth Carolina
12/31/202299012State ProgramSouth Carolina
Page 1 of 1 00016/22-347-0034
Page 2 of 13
Report Number:
Sample Summary Table
Client Project Description:
22-347-0034
Bluelnx Charlotte UST
Lab No Client Sample ID Matrix Date Collected Date Received
12/12/2022 08:30Solids 95439 PL-1 12/13/2022 13:45
12/12/2022 08:40Solids 95440 PL-2 12/13/2022 13:45
Page 3 of 13
Summary of Detected Analytes
QualifiersAnalyzedUnitsResult
Report Number:
Client Sample ID
Method Parameters
Lab Sample ID
22-347-0034
Report Limit
Project:Bluelnx Charlotte UST
V 95439PL-1
J7.17 12/19/2022 17:198015C DRO Diesel Range Organics (C10-C28)mg/Kg - dry 6.14
24.3 12/16/2022 16:39SW-DRYWT Moisture %
V 95440PL-2
J9.71 12/19/2022 18:248015C DRO Diesel Range Organics (C10-C28)mg/Kg - dry 5.52
15.8 12/16/2022 16:39SW-DRYWT Moisture %
Page 4 of 13
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-347-0034
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Natalie Stevens
Huntersville
Received : 12/13/2022
Bluelnx Charlotte UST
Report Date : 12/21/2022
Sample ID :
Lab No :
Sampled:PL-1
95439 Matrix:
12/12/2022 8:30
Solids
Test Results Units MDL MQL By Analytical
Method
Date / Time
Analyzed
DF
24.3 %Moisture 1 12/16/22 16:39 SW-DRYWTAMB
Qualifiers/
Definitions
Estimated valueJDilution FactorDF
Method Quantitation LimitMQL
Page 5 of 13
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-347-0034
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Natalie Stevens
Huntersville
Received : 12/13/2022
Bluelnx Charlotte UST
Report Date : 12/21/2022
Sample ID :
Lab No :
Sampled:PL-1
95439 Matrix:
12/12/2022 8:30
Solids
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
3546
8015C DRO Prep Batch(es):V28008 12/19/22 13:45
7.17 J mg/Kg - dry 6.14 13.2Diesel Range Organics (C10-C28)1 12/19/22 17:19 V28085AMP
8015C DROSurrogate: OTP Surrogate 96.2 Limits: 31-123%12/19/22 17:191 AMP
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
5035 MED
8015C GRO Prep Batch(es):V27761 12/14/22 08:00
<2.73 mg/Kg - dry 2.73 6.61Gasoline Range Organics (C6-C10)50 12/14/22 15:01 V27762TBL
8015C GROSurrogate: a,a,a-Trifluorotoluene 119 Limits: 50-137%12/14/22 15:0150 TBL
Qualifiers/
Definitions
Estimated valueJDilution FactorDF
Method Quantitation LimitMQL
Page 6 of 13
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-347-0034
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Natalie Stevens
Huntersville
Received : 12/13/2022
Bluelnx Charlotte UST
Report Date : 12/21/2022
Sample ID :
Lab No :
Sampled:PL-2
95440 Matrix:
12/12/2022 8:40
Solids
Test Results Units MDL MQL By Analytical
Method
Date / Time
Analyzed
DF
15.8 %Moisture 1 12/16/22 16:39 SW-DRYWTAMB
Qualifiers/
Definitions
Estimated valueJDilution FactorDF
Method Quantitation LimitMQL
Page 7 of 13
,
REPORT OF ANALYSISReport Number :
Project
Information :
NC 28078
22-347-0034
00249
Suite N
TRC Environmental Corporation
9735 Northcross Center Court,
Natalie Stevens
Huntersville
Received : 12/13/2022
Bluelnx Charlotte UST
Report Date : 12/21/2022
Sample ID :
Lab No :
Sampled:PL-2
95440 Matrix:
12/12/2022 8:40
Solids
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
3546
8015C DRO Prep Batch(es):V28008 12/19/22 13:45
9.71 J mg/Kg - dry 5.52 11.9Diesel Range Organics (C10-C28)1 12/19/22 18:24 V28085AMP
8015C DROSurrogate: OTP Surrogate 98.5 Limits: 31-123%12/19/22 18:241 AMP
Analytical Method:
Prep Method:
Test Results Units MDL MQL By Analytical
Batch
Date / Time
Analyzed
DF
5035 MED
8015C GRO Prep Batch(es):V27761 12/14/22 08:00
<2.46 mg/Kg - dry 2.46 5.94Gasoline Range Organics (C6-C10)50 12/14/22 15:30 V27762TBL
8015C GROSurrogate: a,a,a-Trifluorotoluene 118 Limits: 50-137%12/14/22 15:3050 TBL
Qualifiers/
Definitions
Estimated valueJDilution FactorDF
Method Quantitation LimitMQL
Page 8 of 13
Quality Control Data
22-347-0034Report No:
Project Description:
Client ID:TRC Environmental Corporation
Bluelnx Charlotte UST
QC Prep Batch Method:
Total Petroleum Hydrocarbons - Extractable
8015C DRO
V28085QC Analytical Batch(es):
Analysis Method:
Analysis Description:
3546
QC Prep:V28008
Associated Lab Samples: 95439, 95440
LRB-V28008 Matrix: SOLLab Reagent Blank
Parameter
AnalyzedMQLMDLBlank
ResultUnits
%
Recovery
% Rec
Limits
12/19/22 16:3710.04.65<4.65mg/KgDiesel Range Organics (C10-C28)
12/19/22 16:37OTP Surrogate (S)96.2 31-123
LCS-V28008Laboratory Control Sample
Parameter
LCS %RecLCS
Result
Spike
Conc.Units
% Rec
Limits
12080.266.7mg/KgDiesel Range Organics (C10-C28)46-126
91.7OTP Surrogate (S)31-123
V 95439-MS-V28008 V 95439-MSD-V28008Matrix Spike & Matrix Spike Duplicate
MS Result
Parameter
Max
RPD
MS
%Rec
MSD
Result
MSD
Spike
Conc.
MS Spike
Conc.ResultUnits
%Rec
Limits
MSD
%Rec RPD
74.9 11278.666.866.75.43mg/KgDiesel Range Organics (C10-C28)118 50-117 4.8 24
83.4OTP Surrogate (S)87.3 31-123
Page 1 of 3Date:12/21/2022 10:59 AM
Page 9 of 13
Quality Control Data
22-347-0034Report No:
Project Description:
Client ID:TRC Environmental Corporation
Bluelnx Charlotte UST
QC Prep Batch Method:
Total Petroleum Hydrocarbons - Volatile
8015C GRO
V27762QC Analytical Batch(es):
Analysis Method:
Analysis Description:
5035 MED
QC Prep:V27761
Associated Lab Samples: 95439, 95440
LRB-V27761 Matrix: SOLLab Reagent Blank
Parameter
AnalyzedMQLMDLBlank
ResultUnits
%
Recovery
% Rec
Limits
12/14/22 14:345.002.07<2.07mg/KgGasoline Range Organics (C6-C10)
12/14/22 14:34a,a,a-Trifluorotoluene (S)94.0 50-137
LCS-V27761Laboratory Control Sample
Parameter
LCS %RecLCS
Result
Spike
Conc.Units
% Rec
Limits
97.248.650.0mg/KgGasoline Range Organics (C6-C10)41-138
105a,a,a-Trifluorotoluene (S)50-137
V 95440-MS-V27761 V 95440-MSD-V27761Matrix Spike & Matrix Spike Duplicate
MS Result
Parameter
Max
RPD
MS
%Rec
MSD
Result
MSD
Spike
Conc.
MS Spike
Conc.ResultUnits
%Rec
Limits
MSD
%Rec RPD
46.4 92.842.850.050.0<2.07mg/KgGasoline Range Organics (C6-C10)85.6 41-138 8.0 34
103a,a,a-Trifluorotoluene (S)99.8 50-137
Page 2 of 3Date:12/21/2022 10:59 AM
Page 10 of 13
Quality Control Data
22-347-0034Report No:
Project Description:
Client ID:TRC Environmental Corporation
Bluelnx Charlotte UST
Dry Weight Determination
SW-DRYWT
V27949QC Analytical Batch:
Analysis Method:
Analysis Description:
V 95439-DUPDuplicate
Max RPD
Parameter
AnalyzedRPDDUP
Result
Result
Units
20.0 12/16/22 16:391.624.724.3%Moisture
V 95440-DUPDuplicate
Max RPD
Parameter
AnalyzedRPDDUP
Result
Result
Units
20.0 12/16/22 16:393.716.415.8%Moisture
Page 3 of 3Date:12/21/2022 10:59 AM
Page 11 of 13
Fed Ex
UPS
US Postal
Client
Lab
Courier
Other :
Shipment Receipt Form
Customer Number:
Customer Name:
Report Number:22-347-0034
TRC Environmental Corporation
00249
Shipping Method
Shipping container/cooler uncompromised?
Thermometer ID:IRT-15 1.8C
Chain of Custody (COC) present?Yes No
Yes No Not Present
Yes No Not Present
Yes No
COC agrees with sample label(s)? Yes No
COC properly completed
Samples in proper containers?
Sample containers intact?
Sufficient sample volume for indicated test(s)?
All samples received within holding time?
Cooler temperature in compliance?
Yes No
Yes No
Yes No
Yes No
Yes No
Yes NoCooler/Samples arrived at the laboratory on ice.
Samples were considered acceptable as cooling
process had begun.
Yes No
Yes No N/A
Yes No N/A
Yes No N/ASoil VOA method 5035 – compliance criteria met
Water - Sample containers properly preserved
Water - VOA vials free of headspace Yes No N/A
Trip Blanks received with VOAs
Low concentration EnCore samplers (48 hr)
High concentration pre-weighed (methanol -14 d) Low conc pre-weighed vials (Sod Bis -14 d)ü
High concentration container (48 hr)
Custody seals intact on shipping container/cooler?
Custody seals intact on sample bottles?
Number of coolers/boxes received
Yes No
1
Signature:Angelo Norvell Date & Time:12/13/2022 18:18:04
Special precautions or instructions included?
Comments:
Page 12 of 13
Page 13 of 13
Appendix D: Certificate of Liquid and UST Disposal
Fire Department Permit
Charlotte Fire Department
500 Dalton Avenue
Charlotte, NC 28206
CCI ENVIRONMENTAL SERVICES
708 MARTIN LUTHER KING JR DR
THOMASVILLE, NC 27360
FIRE PERMIT
OCCUPANT AND LOCATION FOR WHICH PERMIT IS VALID.
BLUE LINX
3300 PARKSIDE DR
Charlotte NC 28208
PERMIT FOR:Tank Instal/Removal
PERMIT CONDITIONS:
(704) 394-3172
1.THIS PERMIT SHALL BE POSTED ON PREMISES FOR WHICH ISSUED.
2.ANY CHANGE IN THIS PERMIT SHALL REQUIRE PRIOR APPROVAL OF THE FIRE
MARSHAL
3.THE ISSUANCE OF A PERMIT OR APPROVAL OF PLANS SHALL NOT BE DEEMED OR
CONSTRUED TO BE A PERMIT FOR AN APPROVAL OF ANY VIOLATION OF ANY OF THE
PROVISIONS OF THE BUILDINGS AND FIRE CODES.
4.THE LOCATION CAN BE INSPECTED AT ANY TIME BY THE CHARLOTTE FIRE
DEPARTMENT.
VALID FROM:
VALID THROUGH:
11/14/2022
12/01/2023
PERMIT NUMBER:2022-220816547
Mailing Address: