HomeMy WebLinkAboutFA-88354_90172_CA_MRP_20211222December 22, 2021 Mr. Kenneth Currie Hydrogeologist UST Section, Division of Waste Management North Carolina Department of Environmental Quality Systel Building, Suite 714 225 Green Street Fayetteville, North Carolina 28301 Re: 2020 Annual Groundwater Monitoring and AFVR Report Colonial Pipeline Company – Selma Station Incident Number: 90172 Site Ranking: I120D Dear Mr. Currie: On behalf of Colonial Pipeline Company, Apex Companies, LLC has prepared the attached Annual Groundwater Monitoring and Aggressive Fluid and Vapor Recovery (AFVR) Report. This report presents the combined results of the April and October 2020 groundwater sampling events and the March and December 2020 AFVR events performed at the Colonial Pipeline Selma Station (Incident Number 90172). If you have any questions or concerns, please do not hesitate to contact the undersigned at (704) 799-6390. Sincerely, Apex Companies, LLC Jamie Moran Tom Nauman, P.G. Assistant Project Manager Senior Scientist NC License No. 2405 Enclosure cc: Maribeth Hughes, Colonial Pipeline Company Jeff Morrison, Colonial Pipeline Company Colonial Pipeline Company – Selma Station December 22, 2021 2020 Annual Groundwater Monitoring and AFVR Report Page i TABLE OF CONTENTS 1.0 INTRODUCTION ........................................................................................................................................... 1  1.1 Site Background ........................................................................................................................ 1  2.0 FIELD ACTIVITIES ........................................................................................................................................ 2  2.1 Groundwater Gauging and LNAPL Thickness Measurements ............................................... 2  2.2 Groundwater Investigation Activities and Results ................................................................... 2  2.3 Aggressive Fluid Vapor and LNAPL Recovery Activities and Results .................................... 3  3.0 WASTE HANDLING ...................................................................................................................................... 5  4.0 CONCLUSIONS AND RECOMMENDATIONS ........................................................................................... 5  Tables Table 1: Summary of Groundwater Elevation Data Table 2a: Summary of Groundwater Analytical Results – VOCs Table 2b: Summary of Groundwater Analytical Results – Hydrocarbon Fractions Table 3a: AFVR Field Data Sheet – March 2020 Table 3b: AFVR Field Data Sheet – December 2020 Table 4a: Summary of AFVR Effluent Sample Analytical Results – March 2020 Table 4b: Summary of AFVR Effluent Sample Analytical Results – December 2020 Table 5a: Vapor Phase Mass Removal Calculations – March 2020 Table 5b: Vapor Phase Mass Removal Calculations – December 2020 Table 6: Proposed Groundwater Monitoring Plan Summary Figures Figure 1: Site Location Map Figure 2: Site Plan Figure 3: Groundwater Potentiometric Surface Map – Surficial Aquifer (October 2020) Figure 4: Groundwater Analytical Results – Detected Analytes (May & October 2020) Appendices Appendix A: Groundwater Sampling Logs Appendix B: Laboratory Analytical Reports Appendix C: Tank Specific Conversion Table Appendix D: Waste Manifests Colonial Pipeline Company – Selma Station December 22, 2021 2020 Annual Groundwater Monitoring and AFVR Report Page 1 1.0 INTRODUCTION This annual monitoring report presents the results of the May and October 2020 semiannual groundwater monitoring events, as well as results of the March and December 2020 aggressive fluid vapor recovery (AFVR) events performed at the Colonial Pipeline Company (CPC) Selma Station located at 2335 West Oak Street in Selma, North Carolina (the ‘site’). Apex Companies, LLC (Apex) prepared this report on behalf of CPC for submittal to the North Carolina Department of Environmental Quality (NCDEQ). A Site Location Map is provided as Figure 1. The site consists of one aboveground storage tank for the transfer of refined petroleum products, pipelines, a manifold yard, a control building, and associated above- and below-ground piping, as shown on the Site Plan on Figure 2. 1.1 Site Background On September 5, 2013 dead vegetation and an odor were reported at the Site. Emergency response actions were initiated, which included shutting down all delivery/shipper lines running through the affected area of the site and locking out all associated valves. During initial emergency response activities between September 5-18, 2013, approximately 60 gallons of gasoline and approximately 1,600 tons of soil were removed from the suspected release area. CPC estimates that approximately 200 gallons of gasoline were released. The release was assigned Incident Number 90172 by the NCDEQ. No apparent leaks were observed in the underground delivery/shipper lines exposed during the initial excavation activities; however, a corroded section of pipe was discovered in the excavated area. Physical inspection of the corroded area revealed significant pitting and the pipe was subsequently repaired. On September 10, 2013, the three delivery/shipper lines were pressure tested. One of the lines maintained pressure for the duration of the test and was cleared to return to service but the other two lines did not maintain pressure during the test. The pressure loss was attributed to leaking valves. On September 11, 2013, an acoustic emission test was conducted on the two lines that did not pass the pressure test. The test results did not indicate evidence of a leak in either line. The area that exhibited the highest noise during the acoustic emission test was excavated but no evidence of a leak was identified in that area. Following the results of the acoustic emission testing, additional excavation activities conducted between September 13-18, 2013 extended the excavation trench along the pipeline to a total length of 210 feet. Between September 24-26, 2013, the impacted soil was transported to Soilworks, Inc., a permitted soil disposal facility in Selma, North Carolina. Following completion of excavation activities, the trench was backfilled with clean fill and the area was restored. An Initial Assessment Report was submitted to NCDEQ on April 6, 2015, and a Comprehensive Site Assessment (CSA) Report was submitted to NCDEQ on October 29, 2015. A CAP proposing AFVR technology combined with MNA to address petroleum impacted soil and groundwater at the site was submitted to NCDEQ on October 2, 2018 and was approved by the agency on November 5, 2018. Colonial Pipeline Company – Selma Station December 22, 2021 2020 Annual Groundwater Monitoring and AFVR Report Page 2 The site is currently classified as intermediate risk because several dissolved phase constituents of concern (COCs), including benzene, ethylbenzene, naphthalene, toluene, and xylenes, exceed the NCAC 2B Surface Water Standards (2B Standards) by a factor of ten in the shallow, unconfined aquifer, and because an unlined retention pond is located on the adjacent property approximately 500 feet in the direction of groundwater flow from the source area. Mill Creek, the receiving surface water for the retention pond, is located approximately 1,500 feet downgradient of the source area. Mill Creek is classified by NCDEQ Division of Water Resources as a Water Supply Class IV surface water body. 2.0 FIELD ACTIVITIES The following sections provide a summary of the field methods used for the May and October 2020 semiannual groundwater monitoring events, as well as the AFVR events performed in March and December 2020. 2.1 Groundwater Gauging and LNAPL Thickness Measurements Prior to sampling, groundwater monitoring wells were gauged to measure the depth to groundwater and for the presence of light non-aqueous phase liquid (LNAPL). Upon arriving at the site, wells were opened and allowed to equilibrate. Wells were gauged and later sampled in accordance with the United States Environmental Protection Agency (EPA) Region IV Science and Ecosystem Support Division Field Branches Quality System and Technical Procedures. Depths to groundwater and LNAPL were measured using an electronic oil/water interface probe, with a measurement accuracy of 0.01 feet (ft.). The interface probe was thoroughly decontaminated before collecting measurements at each subsequent monitoring well. On May 27, 2020 and October 20, 2020, twelve monitoring wells (AP-1, AP-2, AP-2D, AP-3, AP-4, AP-5, AP-6, AP-7, AP-8, AP-9, AP-10, and AP-11) were gauged. The location of each monitoring well is shown on Figure 2. 2.2 Groundwater Investigation Activities and Results Semiannual groundwater sampling was performed at the site on May 27, 2020 and October 20, 2020. During both 2020 sampling events, groundwater samples were collected from nine monitoring wells (AP-1, AP-2, AP-3, AP-4, AP-5, AP-8, AP-9, AP-10, and AP-11). At each monitoring well location, a baseline set of water quality parameters (temperature, pH, specific conductivity, dissolved oxygen, and turbidity) were measured using a Hanna 9829 water quality meter and a Hach 2100Q turbidimeter. A minimum of three well volumes were purged from each well using a disposable bailer before sample collection. Groundwater sampling logs documenting the groundwater purging and sampling are included as Appendix A. After purging an adequate volume of water from each well, a sample was collected in laboratory supplied bottle ware and placed on ice in a cooler. Samples were submitted for analysis of benzene, toluene, ethylbenzene, xylenes (BTEX) and naphthalene by EPA Method 6200B. Groundwater samples collected on October 20, 2020 were also submitted for laboratory analysis of volatile Colonial Pipeline Company – Selma Station December 22, 2021 2020 Annual Groundwater Monitoring and AFVR Report Page 3 petroleum hydrocarbons (VPH) in accordance with Massachusetts Department of Environmental Protection (MADEP) Method. Samples were submitted under standard chain-of-custody procedures to Shealy Environmental Services, Inc (Shealy), a North Carolina-certified laboratory. Two quality assurance/quality control samples were collected and analyzed for BTEX and naphthalene using EPA Method 6200B and VPH via MADEP Method. During the May 27, 2020 and October 20, 2020 sampling events, DUP-1 was collected as a duplicate sample of AP-9 and AP-11, respectively. One equipment blank (EB-1) was collected following the completion of sampling activities during both sampling events by pouring de-ionized water over a decontaminated interface probe. Groundwater gauging results collected on May 27, 2020 and October 20, 2020 are summarized in Table 1. LNAPL was not detected in either gauging event. Depth to water and top of well casing elevations were used to determine groundwater potentiometric elevations relative to an on-site benchmark referenced to mean sea level datum. For shallow wells that are screened across the water table surface, the groundwater potentiometric surface is approximately equal to the water table elevation. Groundwater potentiometric surface maps for the surficial aquifer unit were developed for the site based on the October 20, 2020 gauging data (Figure 3). The potentiometric surface map indicates that groundwater flows in a multi-directional pattern primarily toward the south, southwest, and southeast which is consistent with historical data. Groundwater analytical results for volatile organic compounds and hydrocarbon fractions during the May and October 2020 sampling events are summarized along with historical analytical results in Table 2a and Table 2b, respectively. Laboratory analytical reports and chain-of-custody records are provided in Appendix B. 2.3 Aggressive Fluid Vapor and LNAPL Recovery Activities and Results Eight-hour AFVR events were conducted on March 5, 2020 and December 15, 2020. Prior to initiating AFVR activities, monitoring wells AP-3, AP-4, AP-5, AP-8, and AP-11 were gauged using an electronic oil/water interface probe capable of detecting depth to water (DTW) and LNAPL (if present) to an accuracy of 0.01 feet. A vacuum truck operated by Legacy Environmental Services, LLC (Legacy) was mobilized to the site. The vacuum truck was attached to the extraction well (AP-11) using vacuum hoses and a piping manifold system. A drop tube was inserted into the extraction well, approximately six inches below the water table surface and an airtight seal was established on the top of the well. The drop tube depth was adjusted periodically during the AFVR event. During the AFVR events, peripheral responses to the vacuums and fluid drawdowns were monitored at nearby wells not used for direct fluid extraction. Vacuum readings as well as DTW measurements at the peripheral wells (AP-3, AP-4, AP-5, and AP-8) were recorded every half hour for the first two hours and every hour thereafter. Colonial Pipeline Company – Selma Station December 22, 2021 2020 Annual Groundwater Monitoring and AFVR Report Page 4 During both the March and December AFVR events, one vacuum truck tank effluent air sample (collected at sample location AP-11) was collected for analysis of volatile organic compounds by EPA Method TO-15 approximately 15 minutes after initiating the AFVR event. A second air sample (collected from sample location AP-11) was collected near the end of the 8-hour AFVR event. Air samples were collected in individual six-liter Summa canisters and submitted under chain-of-custody procedures to Pace Analytical Services, LLC, a North Carolina-certified laboratory. The air emissions from the vacuum truck tank were also qualitatively tested for volatile organic vapors using a photoionization detector (PID), and airflow rates were recorded using a digital anemometer. Following completion of the AFVR pilot test, temporary equipment was removed from the extraction well and peripheral observations wells and DTW measurements were collected from the extraction well and peripheral wells. The volume of fluid recovered in the vacuum truck after the 8-hour AFVR event was also measured and recorded. Field data is summarized in Table 3a and 3b. During the March 2020 and December 2020 AFVR events, approximately 860 and 653 gallons of petroleum impacted water were recovered respectively. The total liquid removed was determined by lowering a measuring stick inside the tank of the vacuum truck and recording the depth of liquid. A tank specific calibration curve table was then used to convert the depth measurements to gallons. A copy of the tank-specific conversion table is provided as Appendix C. The air sample analytical data were evaluated to assess the vapor recovery rates during the AFVR event and to calculate the total volume of vapor-phase petroleum hydrocarbons removed, expressed in equivalent gallons of gasoline. Summaries of the March 2020 and December 2020 air sampling results are provided in Table 4a and Table 4b, respectively, and laboratory reports are included as Appendix B. Vapor mass removal calculations are provided in Table 5a and Table 5b for March 2020 and December 2020 events. Approximately 0.73 pounds (0.117 gallons) of vapor-phase petroleum hydrocarbons (as gasoline) were removed during the March 2020 AFVR event. Comparison of the March 2020 air samples collected within the first 30 minutes and the within the last 30 minutes of the AFVR event indicated a reduction in vapor-phase VOC recovery rates after eight hours of AFVR duration. Approximately 6.44 pounds (1.03 gallons equivalent) of vapor-phase petroleum hydrocarbons (as gasoline) were removed during the December 2020 AFVR event. Comparison of the December 2020 air samples collected within the first 30 minutes and the within the last 30 minutes of the AFVR event indicated an increase in vapor-phase VOC recovery rates after eight hours of AFVR duration. This is most likely the result of a change in sample location. The initial air sample was collected from the vacuum blower. Due to equipment malfunction during the AFVR event, the final air sample location was changed to the vacuum pump. Colonial Pipeline Company – Selma Station December 22, 2021 2020 Annual Groundwater Monitoring and AFVR Report Page 5 3.0 WASTE HANDLING Wastes generated during the AFVR tests were contained within the vacuum truck. Following the completion of each AFVR pilot test the total liquid contained within the vacuum truck was measured. LNAPL was not present. A tank specific conversion table was used to convert the depth of liquid in the vacuum truck to gallons (Appendix C). Waste was transported by Legacy to the Legacy Facility at 3637 N. Graham Street, Charlotte, Mecklenburg County, North Carolina, a North Carolina-permitted waste handling facility. The waste manifests are included in Appendix D. 4.0 CONCLUSIONS AND RECOMMENDATIONS Apex conducted semi-annual groundwater monitoring in May and October of 2020, as well as AFVR events performed in March and December 2020. Results of these activities indicate: LNAPL was not detected in any wells during the reporting period. LNAPL has not been detected in any wells for over 7 years. Groundwater exceedances of NCAC 2L Standards in Benzene, Ethylbenzene, Naphthalene, Toluene, and Xylenes (Total) Approximately 860 gallons of petroleum impacted groundwater were recovered from extraction well AP-11 during the March 2020 AFVR event. Approximately 653 gallons of petroleum impacted groundwater were recovered from extraction well AP-11 during the December 2020 AFVR event. Approximately 0.73 pounds (0.117 gallons equivalent) of vapor-phase petroleum hydrocarbons (as gasoline) were removed during the March 2020 AFVR event. Approximately 6.44 pounds (1.03 gallons equivalent) of vapor-phase petroleum hydrocarbons (as gasoline) were removed during the December 2020 AFVR event. AP-11 will continue to be the primary extraction point; however, additional wells (i.e., AP-4) may be added as extraction wells utilizing a manifold system so that a vacuum can be applied to multiple extraction wells simultaneously. Semiannual groundwater monitoring events will be performed approximately 30 days following each AFVR event. Semiannual groundwater monitoring events are proposed for completion in April and October of each year, and a submittal of an annual groundwater monitoring and AFVR report is proposed by December 31st of each year. A summary of the proposed semiannual groundwater sampling program is provided as Table 6. TABLES Table 1 Summary of Groundwater Elevation Data Colonial Pipeline Company Selma Facility Selma, North Carolina 6/12/2014 --5.72 -- 150.96 12/10/2014 --5.76 -- 150.92 12/31/2014 --4.33 -- 152.35 8/27/2015 --7.48 -- 149.20 6/1/2016 --4.57 -- 152.11 2/13/2019 --3.24 -- 153.44 10/16/2019 --7.97 -- 148.71 5/27/2020 --3.70 -- 152.98 10/20/2020 --4.20 -- 152.48 6/12/2014 --5.61 -- 152.65 12/10/2014 --5.18 -- 153.08 12/31/2014 --3.96 -- 154.30 8/27/2015 --7.71 -- 150.55 6/1/2016 --4.37 -- 153.89 2/13/2019 --2.85 -- 155.41 10/16/2019 --5.98 -- 152.28 5/27/2020 --4.00 -- 154.26 10/20/2020 --3.88 -- 154.38 8/27/2015 --8.45 -- 149.76 6/1/2016 --4.74 -- 153.47 2/13/2019 --5.37 -- 152.84 10/16/2019 --6.19 -- 152.02 5/27/2020 --5.35 -- 152.86 10/20/2020 --4.89 -- 153.32 12/31/2014 --4.32 -- 153.36 8/27/2015 --7.78 -- 149.90 6/1/2016 --4.60 -- 153.08 2/13/2019 --2.75 -- 154.93 6/20/2019 --4.07 -- 153.61 10/16/2019 --6.60 -- 151.08 5/27/2020 --3.55 -- 154.13 10/20/2020 --4.11 -- 153.57 12/31/2014 --4.30 -- 153.56 8/27/2015 --7.81 -- 150.05 6/1/2016 --4.19 -- 153.67 2/13/2019 --2.63 -- 155.23 6/20/2019 --3.68 -- 154.18 10/16/2019 --NM -- NM 5/27/2020 --3.43 -- 154.43 10/20/2020 --3.80 -- 154.06 Corrected Groundwater Elevation (ft. MSL) Well No. Top of Casing Elevation (ft. MSL) Depth to LNAPL (ft. TOC) Depth to Groundwater (ft. TOC) LNAPL Thickness (ft.) Date AP-1 156.68 AP-2 158.26 158.21AP-2D AP-3 157.68 AP-4 157.86 Page 1 of 3 Table 1 Summary of Groundwater Elevation Data Colonial Pipeline Company Selma Facility Selma, North Carolina Corrected Groundwater Elevation (ft. MSL) Well No. Top of Casing Elevation (ft. MSL) Depth to LNAPL (ft. TOC) Depth to Groundwater (ft. TOC) LNAPL Thickness (ft.) Date 12/31/2014 --3.97 -- 154.59 8/27/2015 --7.85 -- 150.71 6/1/2016 --5.48 -- 153.08 2/13/2019 --3.57 -- 154.99 6/20/2019 --5.55 -- 153.01 10/16/2019 --6.36 -- 152.20 5/27/2020 --3.50 -- 155.06 10/20/2020 --4.87 -- 153.69 12/31/2014 --2.06 -- 156.84 8/27/2015 --5.60 -- 153.30 6/1/2016 --2.77 -- 156.13 2/13/2019 --3.13 -- 155.77 10/16/2019 --2.48 -- 156.42 5/27/2020 --1.99 -- 156.91 10/20/2020 --2.19 -- 156.71 8/27/2015 --8.88 -- 151.12 6/1/2016 --5.24 -- 154.76 2/13/2019 --4.22 -- 155.78 10/16/2019 --7.04 -- 152.96 5/27/2020 --5.02 -- 154.98 10/20/2020 --4.81 -- 155.19 8/27/2015 --8.55 -- 150.22 6/1/2016 --6.59 -- 152.18 2/13/2019 --4.13 -- 154.64 6/20/2019 --5.11 -- 153.66 10/16/2019 --6.00 -- 152.77 5/27/2020 --4.56 -- 154.21 10/20/2020 --4.20 -- 154.57 8/27/2015 --7.76 -- 149.13 6/1/2016 --4.76 -- 152.13 2/13/2019 --3.44 -- 153.45 10/16/2019 --NM -- NM 5/27/2020 --3.80 -- 153.09 10/20/2020 --4.22 -- 152.67 8/27/2015 --8.13 -- 150.02 6/1/2016 --4.92 -- 153.23 2/13/2019 --3.40 -- 154.75 10/16/2019 --6.60 -- 151.55 5/27/2020 --3.80 -- 154.35 10/20/2020 --4.39 -- 153.76 158.15AP-10 AP-5 158.56 AP-6 158.90 AP-7 160.00 AP-8 158.77 AP-9 156.89 Page 2 of 3 Table 1 Summary of Groundwater Elevation Data Colonial Pipeline Company Selma Facility Selma, North Carolina Corrected Groundwater Elevation (ft. MSL) Well No. Top of Casing Elevation (ft. MSL) Depth to LNAPL (ft. TOC) Depth to Groundwater (ft. TOC) LNAPL Thickness (ft.) Date 6/1/2016 --5.07 -- 153.22 2/13/2019 --4.11 -- 154.18 6/20/2019 --4.40 -- 153.89 10/16/2019 --6.63 -- 151.66 5/27/2020 --4.44 -- 153.85 10/20/2020 --4.55 -- 153.74 MW-7* 161.72 6/11/2014 --9.77 -- 151.95 Notes: ft. - Feet MSL - Mean Sea Level TOC - Top of Casing -- - Not Detected LNAPL - Light Non-aqueous Phase Liquid *MW-7 is located on the adjacent Marathon property. Gauging data supplied by others. AP-11 158.29 Page 3 of 3 Table 2a Summary of Groundwater Analytical Results - VOCs Colonial Pipeline Company Selma Facility Selma, North Carolina Benzene2-Butanone (MEK)n-Butylbenzenesec-ButylbenzeneChloromethaneDiisopropyl EtherEthylbenzeneIsopropylbenzenep-IsopropyltolueneMethylene Chloride4-Methyl-2-pentanone (MIBK)Methyl-tert-Butyl EtherNaphthalenen-PropylbenzeneStyreneToluene1,2,4-Trimethylbenzene1,3,5-TrimethylbenzeneXylenes (Total)Date Collected Depth to Water (DTW)µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L 5,000 4,000,000 6,900 8,500 3,000 70,000 84,500 25,000 11,700 5,000 100,000 20,000 6,000 30,000 70,000 260,000 28,500 25,000 85,500 1.19 20,000*3.9*NE 2.6*20,000*68**250*320*20**2,800*19*12*80*NE 11 390*130*670* 1 4,000 70 70 3 NE 600 70 25 5 100 20 6 70 70 600 400 400 500 06/12/14 5.72 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 0.47 J ND ND ND 12/10/14 5.76 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Duplicate (AP-1)12/10/14 AP-1 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 08/27/15 7.48 ND NS ND ND ND ND ND ND ND ND NS ND ND ND ND ND ND ND ND 02/13/19 3.24 290 NS NS NS NS NS 0.44 J NS NS NS NS NS 7.6 NS NS 1.2 NS NS 19 10/16/19 7.97 280 NS NS NS NS NS <1.2 NS NS NS NS NS 10 NS NS <1.2 NS NS 1.3J 05/27/20 3.70 <0.50 NS NS NS NS NS <0.50 NS NS NS NS NS <0.50 NS NS <0.50 NS NS <0.50 10/20/20 4.20 179 NS NS NS NS NS <2.0 NS NS NS NS NS 1.3 J NS NS 1.4 J NS NS <2.0 06/12/14 5.61 2,620 ND ND ND ND ND 297 11.3 J ND 40.2 J ND 7.9 J 48.6 J 27.8 ND 840 251 66.7 1,879 12/10/14 5.18 1,890 ND ND ND ND ND 278 ND ND ND ND 3.9 ND ND 1.1 464 199 68 1,590 08/27/15 7.71 1,200 NS ND ND ND ND 110 12 ND ND NS ND 29 18 ND 300 59 69 750 Duplicate (AP-2)08/27/15 7.71 1,300 NS ND ND ND ND 120 ND ND ND NS ND 37 20 J ND 320 67 71 750 06/01/16 4.37 1,700 NS 19 <10 <10 <10 480 25 12 <10 NS <10 79 70 <10 240 480 140 1,005 02/13/19 2.85 1,300 NS NS NS NS NS 490 NS NS NS NS NS 94 NS NS 760 NS NS 1,100 10/16/19 5.98 609 NS NS NS NS NS 242 NS NS NS NS NS 55.6 NS NS 92.3 NS NS 350 05/27/20 4.00 180 NS NS NS NS NS 130 NS NS NS NS NS 23 NS NS 43 NS NS 77 10/20/20 3.88 498 NS NS NS NS NS 220 NS NS NS NS NS 49.1 NS NS 159 NS NS 478 Gross Contamination Levels NCAC 2B Standards (Class WS Waters) AP-2 AP-1 Analytical Method Volatile Organic Compounds Sample ID Constituent of Concern NCAC 2L Standards AP-1 AP-2 Page 1 of 5 Table 2a Summary of Groundwater Analytical Results - VOCs Colonial Pipeline Company Selma Facility Selma, North Carolina Benzene2-Butanone (MEK)n-Butylbenzenesec-ButylbenzeneChloromethaneDiisopropyl EtherEthylbenzeneIsopropylbenzenep-IsopropyltolueneMethylene Chloride4-Methyl-2-pentanone (MIBK)Methyl-tert-Butyl EtherNaphthalenen-PropylbenzeneStyreneToluene1,2,4-Trimethylbenzene1,3,5-TrimethylbenzeneXylenes (Total)Date Collected Depth to Water (DTW)µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L 5,000 4,000,000 6,900 8,500 3,000 70,000 84,500 25,000 11,700 5,000 100,000 20,000 6,000 30,000 70,000 260,000 28,500 25,000 85,500 1.19 20,000*3.9*NE 2.6*20,000*68**250*320*20**2,800*19*12*80*NE 11 390*130*670* 1 4,000 70 70 3 NE 600 70 25 5 100 20 6 70 70 600 400 400 500 Gross Contamination Levels NCAC 2B Standards (Class WS Waters) Analytical Method Volatile Organic Compounds Sample ID Constituent of Concern NCAC 2L Standards 08/27/15 8.45 2.8 NS ND ND ND ND ND ND ND ND NS ND 0.42 J ND ND 0.73 ND ND 1.97 06/01/16 4.74 1.1 NS <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 NS <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <1.0 02/13/19 5.37 1.0 NS NS NS NS NS <0.50 NS NS NS NS NS <0.50 NS NS <0.50 NS NS <0.50 AP-3 12/31/14 4.32 294 ND ND ND 2.8 0.24 J 19.9 ND ND ND 0.90 J ND 2.7 ND ND 43.1 ND ND 142 Duplicate (AP-3)12/31/14 4.32 288 ND ND ND 2.9 0.24 J 20.3 ND ND ND ND ND 3.1 ND ND 42.3 ND ND 143 08/27/15 7.78 840 NS ND ND ND ND 150 5.7 ND ND NS ND 22 16 ND 600 78 30 570 06/01/16 4.60 120 NS <0.50 <0.50 <0.50 <0.50 2.4 <0.50 <0.50 <0.50 NS <0.50 <0.50 0.17 J <0.50 1.2 0.69 0.32 J 35 02/13/19 2.75 5.5 NS NS NS NS NS <0.50 NS NS NS NS NS <0.50 NS NS <0.50 NS NS 0.42 J 06/20/19 4.07 7.3 NS NS NS NS NS <0.50 NS NS NS NS NS <0.50 NS NS <0.50 NS NS 0.77 10/16/19 6.60 6.2 NS NS NS NS NS 1.4 NS NS NS NS NS <2.0 NS NS 2.2 NS NS 5.6 05/27/20 3.55 4.0 NS NS NS NS NS <0.50 NS NS NS NS NS <0.50 NS NS <0.50 NS NS <0.50 10/20/20 4.11 2.2 NS NS NS NS NS <1.0 NS NS NS NS NS 2.0 NS NS <1.0 NS NS <1.0 12/31/14 4.30 947 ND ND ND 8.1 0.91 J 61.6 ND ND ND ND 0.79 J 22.3 ND ND 119 ND ND 417 08/27/15 7.81 750 NS ND ND ND ND 82 3.5 ND ND NS 1.0 J 15 7.6 ND 280 55 14 460 06/01/16 4.19 95 NS <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 NS <0.50 <0.50 <0.50 <0.50 0.48 J <0.50 <0.50 <1.0 02/13/19 2.63 31 NS NS NS NS NS <0.50 NS NS NS NS NS <0.50 NS NS <0.50 NS NS 0.49 J 06/20/19 3.68 160 NS NS NS NS NS 110 NS NS NS NS NS 20 NS NS 330 NS NS 670 10/16/19 NM 0.70 NS NS NS NS NS <0.50 NS NS NS NS NS <2.0 NS NS <0.50 NS NS <1.0 05/27/20 3.43 35 NS NS NS NS NS 0.77 NS NS NS NS NS <0.50 NS NS <0.50 NS NS 1.9 10/20/20 3.80 37.7 NS NS NS NS NS 6.0 NS NS NS NS NS 3.4 NS NS <1.0 NS NS 8.4 AP-2D AP-4 AP-3 Page 2 of 5 Table 2a Summary of Groundwater Analytical Results - VOCs Colonial Pipeline Company Selma Facility Selma, North Carolina Benzene2-Butanone (MEK)n-Butylbenzenesec-ButylbenzeneChloromethaneDiisopropyl EtherEthylbenzeneIsopropylbenzenep-IsopropyltolueneMethylene Chloride4-Methyl-2-pentanone (MIBK)Methyl-tert-Butyl EtherNaphthalenen-PropylbenzeneStyreneToluene1,2,4-Trimethylbenzene1,3,5-TrimethylbenzeneXylenes (Total)Date Collected Depth to Water (DTW)µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L 5,000 4,000,000 6,900 8,500 3,000 70,000 84,500 25,000 11,700 5,000 100,000 20,000 6,000 30,000 70,000 260,000 28,500 25,000 85,500 1.19 20,000*3.9*NE 2.6*20,000*68**250*320*20**2,800*19*12*80*NE 11 390*130*670* 1 4,000 70 70 3 NE 600 70 25 5 100 20 6 70 70 600 400 400 500 Gross Contamination Levels NCAC 2B Standards (Class WS Waters) Analytical Method Volatile Organic Compounds Sample ID Constituent of Concern NCAC 2L Standards 12/31/14 3.97 454 2.6 J ND ND 3.2 0.38 J 54.5 ND ND ND ND 0.56 J 10.8 ND 0.35 J 145 ND ND 292 08/27/15 7.85 970 NS ND ND ND ND 170 9.3 J ND ND NS ND 22 14 ND 360 76 19 590 06/01/16 5.48 550 NS <2.5 <2.5 <2.5 <2.5 110 3.7 <2.5 <2.5 NS <2.5 18 8.9 <2.5 80 70 15 430 DUP-1 (AP-5)06/01/16 5.48 580 NS <2.5 <2.5 <2.5 <2.5 120 4.1 <2.5 <2.5 NS <2.5 20 9.1 <2.5 100 73 16 460 02/13/19 3.57 82 NS NS NS NS NS 76 NS NS NS NS NS 12 NS NS 0.53 NS NS 210 06/20/19 4.79 79 NS NS NS NS NS 140 NS NS NS NS NS 35 NS NS 29 NS NS 470 10/16/19 6.36 92.6 NS NS NS NS NS 118 NS NS NS NS NS 29.2 NS NS 14.4 NS NS 456 05/27/20 3.50 42 NS NS NS NS NS 80 NS NS NS NS NS 17 NS NS 17 NS NS 280 10/20/20 4.87 41.5 NS NS NS NS NS 96.3 NS NS NS NS NS 26.4 NS NS 3.3 NS NS 269 12/31/14 2.06 0.83 J ND ND ND ND ND 0.38 J ND ND ND ND ND 0.59 J ND ND 0.53 J ND ND 2.29 J 08/27/15 8.64 ND NS ND ND ND ND ND ND ND ND NS ND 0.47 J ND ND ND ND ND ND 02/13/19 3.13 <0.50 NS NS NS NS NS <0.50 NS NS NS NS NS <0.50 NS NS <0.50 NS NS <0.50 08/27/15 8.88 310 NS ND ND ND ND 210 10 ND ND NS ND 38 29 ND 970 220 60 1,250 06/01/16 5.24 940 NS <25 <25 <25 <25 1,000 52 <25 <25 NS <25 160 160 <25 2,300 1,200 280 3,870 02/13/19 4.22 130 NS NS NS NS NS 670 NS NS NS NS NS 110 NS NS 52 NS NS 780 DUP-1 (AP-7)02/13/19 4.22 130 NS NS NS NS NS 670 NS NS NS NS NS 110 NS NS 59 NS NS 860 AP-5 AP-6 AP-7 AP-5 Page 3 of 5 Table 2a Summary of Groundwater Analytical Results - VOCs Colonial Pipeline Company Selma Facility Selma, North Carolina Benzene2-Butanone (MEK)n-Butylbenzenesec-ButylbenzeneChloromethaneDiisopropyl EtherEthylbenzeneIsopropylbenzenep-IsopropyltolueneMethylene Chloride4-Methyl-2-pentanone (MIBK)Methyl-tert-Butyl EtherNaphthalenen-PropylbenzeneStyreneToluene1,2,4-Trimethylbenzene1,3,5-TrimethylbenzeneXylenes (Total)Date Collected Depth to Water (DTW)µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L 5,000 4,000,000 6,900 8,500 3,000 70,000 84,500 25,000 11,700 5,000 100,000 20,000 6,000 30,000 70,000 260,000 28,500 25,000 85,500 1.19 20,000*3.9*NE 2.6*20,000*68**250*320*20**2,800*19*12*80*NE 11 390*130*670* 1 4,000 70 70 3 NE 600 70 25 5 100 20 6 70 70 600 400 400 500 Gross Contamination Levels NCAC 2B Standards (Class WS Waters) Analytical Method Volatile Organic Compounds Sample ID Constituent of Concern NCAC 2L Standards 08/27/15 8.55 240 NS ND ND ND ND 63 3.9 ND ND NS ND 1.8 J 6.7 ND 35 39 16 330 06/01/16 6.59 2,500 NS <25 9.9 J <25 <25 1,800 71 <25 12 J NS <25 280 220 <25 6,800 1,600 410 8,400 02/13/19 4.13 710 NS NS NS NS NS 2,200 NS NS NS NS NS 420 NS NS 110 NS NS 6,500 06/20/19 5.11 520 NS NS NS NS NS 2,200 NS NS NS NS NS 500 NS NS 89 NS NS 6,000 10/16/19 6.00 311 NS NS NS NS NS 1,180 NS NS NS NS NS 355 NS NS 53.4 NS NS 2,500 05/27/20 4.56 200 NS NS NS NS NS 1,300 NS NS NS NS NS 290 NS NS <25 NS NS 2,000 10/20/20 4.20 130 NS NS NS NS NS 884 NS NS NS NS NS 355 NS NS <5.0 NS NS 963 08/27/15 7.76 ND NS ND ND ND ND ND ND ND ND NS ND ND ND ND 0.39 J ND ND ND 02/13/19 3.44 <0.50 NS NS NS NS NS <0.50 NS NS NS NS NS <0.50 NS NS <0.50 NS NS <0.50 10/16/19 Not sampled as well was submerged in water 05/27/20 3.80 <0.50 NS NS NS NS NS <0.50 NS NS NS NS NS <0.50 NS NS <0.50 NS NS <0.50 DUP-1 (AP-9)05/27/20 3.80 <0.50 NS NS NS NS NS <0.50 NS NS NS NS NS <0.50 NS NS <0.50 NS NS <0.50 AP-9 10/20/20 4.22 <1.0 NS NS NS NS NS <1.0 NS NS NS NS NS <1.0 NS NS <1.0 NS NS <1.0 08/27/15 8.13 ND NS ND ND ND ND ND ND ND ND NS ND ND ND ND ND ND ND ND 02/13/19 3.40 910 NS NS NS NS NS 95 NS NS NS NS NS 12 NS NS 33 NS NS 120 10/16/19 6.60 870 NS NS NS NS NS 119 NS NS NS NS NS 19.8 NS NS 31.7 NS NS 151 05/27/20 3.80 1,200 NS NS NS NS NS 310 NS NS NS NS NS 44 NS NS 59 NS NS 330 10/20/20 4.39 1,100 NS NS NS NS NS 274 NS NS NS NS NS 43.6 NS NS 25.7 NS NS 213 AP-10 AP-9 AP-8 Page 4 of 5 Table 2a Summary of Groundwater Analytical Results - VOCs Colonial Pipeline Company Selma Facility Selma, North Carolina Benzene2-Butanone (MEK)n-Butylbenzenesec-ButylbenzeneChloromethaneDiisopropyl EtherEthylbenzeneIsopropylbenzenep-IsopropyltolueneMethylene Chloride4-Methyl-2-pentanone(MIBK)Methyl-tert-Butyl EtherNaphthalenen-PropylbenzeneStyreneToluene1,2,4-Trimethylbenzene1,3,5-TrimethylbenzeneXylenes (Total)Date Collected Depth to Water (DTW)µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L µg/L 5,000 4,000,000 6,900 8,500 3,000 70,000 84,500 25,000 11,700 5,000 100,000 20,000 6,000 30,000 70,000 260,000 28,500 25,000 85,500 1.19 20,000*3.9*NE 2.6*20,000*68**250*320*20**2,800*19*12*80*NE 11 390*130*670* 1 4,000 70 70 3 NE 600 70 25 5 100 20 6 70 70 600 400 400 500 Gross Contamination Levels NCAC 2B Standards (Class WS Waters) Analytical Method Volatile Organic Compounds Sample ID Constituent of Concern NCAC 2L Standards 06/01/16 5.07 7,500 NS <100 <100 <100 <100 2,700 90 J <100 <100 NS <100 450 250 <100 29,000 2,200 510 19,000 02/13/19 4.11 2,000 NS NS NS NS NS 2,900 NS NS NS NS NS 540 NS NS 15,000 NS NS 18,000 06/20/19 4.43 270 NS NS NS NS NS 660 NS NS NS NS NS 310 NS NS 200 NS NS 4,700 DUP 062019 (AP-11)06/20/19 4.43 240 NS NS NS NS NS 560 NS NS NS NS NS 290 NS NS 180 NS NS 4,000 10/16/19 6.63 168 NS NS NS NS NS 560 NS NS NS NS NS 212 NS NS 498 NS NS 2,750 05/27/20 4.44 77 NS NS NS NS NS 460 NS NS NS NS NS 170 NS NS 23 NS NS 1,700 10/20/20 4.55 62.5 NS NS NS NS NS 556 NS NS NS NS NS 250 NS NS 62.8 NS NS 713 DUP-1 (AP-11)10/20/20 4.55 50.6 NS NS NS NS NS 477 NS NS NS NS NS 234 NS NS 34.6 NS NS 552 AP-11 Notes: µg/L - micrograms per liter WS - Water Supply NE - No standard established VOC - Volatile Organic Compounds J - Estimated concentration below laboratory reporting limit ND - Analyte concentration is below laboratory practical quantitative limits NS - Not Sampled Bold values exceed the NCAC 2L Standard Shaded values exceed the 2B Standard by a factor of 10. Italicized values exceed Gross Contamination Levels *NC Protective Value for Surface Waters - criteria may be based on limited toxicological information. **EPA Nationally Recommended Water Quality Criteria for Aquatic Life and Human Health. AP-11 Page 5 of 5 Table 2b Summary of Groundwater Analytical Results – Hydrocarbon Fractions Colonial Pipeline Company Selma Facility Selma, North Carolina C5-C8 Aliphatics C9-C12 Aliphatics C9-C18 Aliphatics C19-C36 Aliphatics C9-C10 Aromatics C11-C22 Aromatics Date Collected Depth to Water (DTW)µg/L µg/L µg/L µg/L µg/L µg/L 125(S)*210(S)* 400 10,000 06/12/14 5.72 ND ND NS NS ND NS 12/10/14 5.76 ND ND NS NS ND NS Duplicate (AP-1)12/10/14 5.76 ND ND NS NS ND NS 08/27/15 7.48 ND ND ND ND ND ND 02/13/19 3.24 510 <380 NS NS 41 J NS 10/16/19 7.97 1,190 <50 NS NS 61 NS 10/20/20 4.20 270 <100 NS NS 56.2 J NS 06/12/14 5.61 13,200 6,320 NS NS ND NS 12/10/14 5.18 4,860 2,900 NS NS ND NS 08/27/15 7.71 3,700 J 1,500 J ND ND 710 ND DUP-1 (AP-2)08/27/15 7.71 5,200 1,500 J ND ND 710 ND 06/01/16 4.37 7,300 1,700 NS NS 1,400 NS 02/13/19 2.85 5,000 1,900 NS NS 960 NS 10/16/19 5.98 4,170 1,120 NS NS 742 NS 10/20/20 3.88 2,880 1,450 NS NS 639 NS 08/27/15 8.45 ND 11 J ND ND ND ND 06/01/16 4.74 <75 <75 NS NS <25 NS 02/13/19 5.37 <75 <75 NS NS <25 NS AP-3 12/31/14 4.32 529 ND NS NS ND NS Duplicate (AP-3)12/31/14 4.32 689 434 NS NS ND NS 08/27/15 7.78 3,900 1,000 J ND ND 280 ND 06/01/16 4.6 200 50 J NS NS <25 NS 02/13/19 2.75 <75 <75 NS NS <25 NS 06/20/19 4.07 <75 <75 NS NS <25 NS 10/16/19 6.60 <50 <50 NS NS <50 NS 10/20/20 4.11 <100 <100 NS NS 39.2 J NS 12/31/14 4.30 1,750 ND NS NS ND NS 08/27/15 7.81 2,300 J ND ND ND ND ND 06/01/16 4.19 83 <75 NS NS <25 NS 02/13/19 2.63 33 J <75 NS NS <25 NS 06/20/19 3.68 890 1,100 NS NS 340 NS 10/16/19 NM <50 <50 NS NS <50 NS 10/20/20 3.80 105 <100 NS NS 42.4 J NS AP-1 AP-2 200 MADEP EPH/VPH Sample ID Constituent of Concern NCAC 2L Standards 830(S)* Analytical Method NCAC 2B Standards (Class WS Water) 700 180(S)* AP-1 AP-2 AP-2D AP-3 AP-4 Page 1 of 3 Table 2b Summary of Groundwater Analytical Results – Hydrocarbon Fractions Colonial Pipeline Company Selma Facility Selma, North Carolina C5-C8 Aliphatics C9-C12 Aliphatics C9-C18 Aliphatics C19-C36 Aliphatics C9-C10 Aromatics C11-C22 Aromatics Date Collected Depth to Water (DTW)µg/L µg/L µg/L µg/L µg/L µg/L 125(S)*210(S)* 400 10,000 200 MADEP EPH/VPH Sample ID Constituent of Concern NCAC 2L Standards 830(S)* Analytical Method NCAC 2B Standards (Class WS Water) 700 180(S)* 12/31/14 3.97 1,020 865 NS NS ND NS 08/27/15 7.85 3,000 J 1,200 J ND ND ND ND 06/01/16 5.48 1,200 540 NS NS 220 NS DUP-1 (AP-5)06/01/16 5.48 1,100 510 NS NS 210 NS 02/13/19 3.57 500 360 NS NS 180 NS 06/20/19 4.79 550 740 NS NS 320 NS 10/16/19 6.36 1,050 1,320 NS NS 600 NS 10/20/20 4.87 305 502 NS NS 245 NS 12/31/14 2.06 ND ND NS NS ND NS 08/27/15 8.64 80 ND ND ND ND ND 02/13/19 3.13 <75 <75 NS NS <25 NS 08/27/15 8.88 2,200 1,500 ND ND 700 170 06/01/16 5.24 11,000 4,300 NS NS 2,700 NS 02/13/19 4.22 4,600 2,500 NS NS 2,500 NS DUP-1 (AP-7)02/13/19 4.22 4,400 3,900 NS NS 2,600 NS 08/27/15 8.55 660 370 J ND ND 150 ND 06/01/16 6.59 18,000 9,400 NS NS 4,500 NS 02/13/19 4.13 5,900 12,000 NS NS 8,100 NS 06/20/19 5.11 4,300 11,000 NS NS 7,600 NS 10/16/19 6.00 4,120 7,170 NS NS 6,240 NS 10/20/20 4.20 2,790 8,250 NS NS 3,750 NS 08/27/15 7.76 ND ND ND ND ND ND 02/13/19 3.44 <75 <75 NS NS <25 NS 10/20/20 4.22 <100 55.9 J NS NS 33.4 J NS 08/27/15 8.13 ND ND ND ND ND 9,000 02/13/19 3.4 2,200 400 J NS NS 240 J NS 10/16/19 6.60 5,340 781 NS NS 465 NS 10/20/20 4.39 4,020 946 NS NS 474 NS AP-5 AP-7 AP-9 AP-10 AP-8 AP-6 Page 2 of 3 Table 2b Summary of Groundwater Analytical Results – Hydrocarbon Fractions Colonial Pipeline Company Selma Facility Selma, North Carolina C5-C8 Aliphatics C9-C12 Aliphatics C9-C18 Aliphatics C19-C36 Aliphatics C9-C10 Aromatics C11-C22 Aromatics Date Collected Depth to Water (DTW)µg/L µg/L µg/L µg/L µg/L µg/L 125(S)*210(S)* 400 10,000 200 MADEP EPH/VPH Sample ID Constituent of Concern NCAC 2L Standards 830(S)* Analytical Method NCAC 2B Standards (Class WS Water) 700 180(S)* 06/01/16 5.07 47,000 19,000 NS NS 5,900 NS 02/13/19 4.11 25,000 23,000 NS NS 9,000 NS 06/20/19 4.43 1,600 8,700 NS NS 7,700 NS DUP 062019 (AP-11)06/20/19 4.43 1,700 10,000 NS NS 5,600 NS 10/16/19 6.63 2,270 6,560 NS NS 7,470 NS 10/20/20 4.55 1,010 6,710 NS NS 3,450 NS DUP-1 (AP-11)10/20/20 4.55 1,040 7,050 NS NS 3,550 NS Notes: µg/L - micrograms per liter Only detected constituents are shown VPH - Volatile Petroleum Hydrocarbons according to the Massachusetts Department of Environmental Protection (MADEP) Method EPH - Extractable Petroleum Hydrocarbons according to the MADEP Method WS - Water Supply J - Estimated concentration below laboratory reporting limit ND - Analyte concentration is below laboratory practical quantitative limits NS - Not sampled Bold values exceed the NCAC 2L Standard Shaded values exceed the 2B Standard by a factor of 10. *NC Protective Value for Surface Waters - criteria may be based on limited toxicological information. S - Toxicity exceeds solubility, no visible sheen or free product in water AP-11 Page 3 of 3 Table 3aAFVR Field Data Sheet- March 2020Colonial Pipeline CompanySelma StationSelma, NCStinger Depth(ft. BTOC)Vacuum at Well(in Hg)PID/FID atWell Head(ppm)AP-11 AP-11 AP-3 AP-4 AP-5 AP-8 AP-3 AP-4 AP-5 AP-8 AP-11 AP-113/5/20 7:50 AM5.0------3.052.812.844.383.45----525 / 81503/5/20 8:30 AM 5.0 23.0 21.0 0.00 -0.05 -0.44 -1.00 3.08 2.85 3.02 4.79 5.00 3348 179.2 34.14 68.35 -3/5/20 9:00 AM 5.5 23.0 21.0 0.00 -0.05 -0.28 -1.20 3.13 2.85 3.12 4.78 5.50 4024 192.5 25.14 51.30 -3/5/20 9:30 AM 6.0 23.5 21.0 0.00 0.00 0.00 -1.203.16 2.85 3.16 4.89 6.00 4129 199.2 24.99 50.19 -3/5/20 10:00 AM 6.5 23.5 21.0 0.00 0.00 -0.08 -0.40 3.21 2.89 3.23 5.10 6.50 4002 198.7 23.28 48.35 -3/5/20 11:00 AM 6.5 23.5 21.0 0.00 0.00 -0.04 -0.40 3.31 2.96 3.32 5.20 6.50 4120 >200 23.17 47.29 -3/5/20 12:00 PM 6.5 23.5 21.0 -0.09 0.00 -0.02 -0.20 3.33 3.01 3.38 5.28 6.50 4012 >200 22.22 45.50 -3/5/20 1:00 PM 7.0 24.0 22.0 -0.02 0.00 0.00 -0.20 3.39 3.06 3.42 5.34 7.00 4350 >200 18.37 38.05 -3/5/20 2:00 PM 7.0 24.0 22.0 0.00 0.00 0.00 -0.203.42 3.08 3.44 5.38 7.00 4388 >200 17.27 33.41 -3/5/20 3:00 PM 8.5 24.5 22.0 0.00 0.00 0.00 -0.303.46 3.12 3.46 5.42 8.50 4292 186.3 15.31 30.47 -3/5/20 4:00 PM 9.5 27.0 22.0 0.00 -0.02 0.00 -0.30 3.48 3.15 3.48 5.45 9.50 4361 197.6 14.82 29.93 1.7 / 4.23/5/20 4:20 PM-------3.503.193.504.905.61----107 / 849Average 6.6 24.0 21.4 0.0 0.0 -0.1 -0.5 3.3 3.0 3.3 5.1 6.4 4102.6 192.3 21.9 44.3 211.2 / 9003.2Notes:dash indicates that no reading was availableNM = Not MeasuredPID = Photo Ionization DetectorFID = Flame Ionization DetectorAFVR = Aggressive Fluid Vapor Recoveryin Hg = Inches MercuryLNAPL = Light Non‐Aqueous Phase LiquidFPM = Feet Per Minuteppm = parts per millionVAC  = Vacuum °F = degrees Fahrenheitft = feetDate/TimeVAC @ Truck (in Hg)Air Flow(at Blower - FPM)FID(at Blower - ppm)Depth to Water/LNAPL (TOC)PID(at Blower - ppm)Temp(at Blower - °F)Vacuum at Surrounding Wells(Inches of Water Column)1 of 1 Table 3bAFVR Field Data Sheet- December 2020Colonial Pipeline CompanySelma StationSelma, NCStinger Depth (ft. BTOC)Vacuum at Well (in Hg)PID/FID at Well Head (ppm)AP-11 AP-11 AP-3 AP-4 AP-5 AP-8 AP-3 AP-4 AP-5 AP-8 AP-11 AP-1112/15/20 7:40 AM-------3.303.493.363.743.72----0.01 / 0.1412/15/20 8:30 AM 5.0 14.0 18.0 0.00 0.10 0.11 0.24 3.22 3.56 3.41 4.16 - 3995 100.4 0.63 1.84 -12/15/20 9:00 AM5.015.018.00.000.030.061.003.343.573.434.43------12/15/20 9:30 AM 5.0 16.0 18.0 0.10 0.10 0.13 0.04 3.35 3.60 3.48 4.68 - 3799 161.1 0.59 2.29 -12/15/20 10:00 AM5.016.018.00.100.070.040.103.383.633.544.77------12/15/20 10:30 AM 5.0 16.0 18.0 0.00 0.10 0.03 0.03 3.41 3.66 3.58 4.85 - 4255 141.7 0.47 3.13 -12/15/20 11:30 AM 5.0 16.0 18.0 0.00 0.07 0.14 0.11 3.46 3.69 3.62 4.95 - 4087 148.5 0.42 3.28 -12/15/20 12:30 PM 5.0 16.0 18.0 0.10 0.09 0.02 0.12 3.49 3.69 3.66 5.00 - 3581 >200.0 0.51 2.61 -12/15/20 1:30 PM 5.0 20.0 20.0 0.10 0.07 0.06 0.71 3.51 3.70 3.65 5.03 - 731 53.5 NM NM -12/15/20 2:30 PM 5.0 20.0 20.0 0.10 0.08 0.17 0.60 3.53 3.75 3.69 5.11 - 576 78.1 NM NM -12/15/20 3:30 PM 5.0 20.0 20.0 0.00 0.05 0.00 1.00 3.56 3.77 3.66 5.00 - 310 58.7 NM NM -12/15/20 4:30 PM 5.0 18.0 20.0 0.10 0.10 0.00 0.95 3.58 3.80 3.70 5.12 - 481 57.1 NM NM -12/15/20 4:45 PM-------3.583.823.704.745.72----NMAverage 5.0 17.0 18.7 0.05 0.08 0.07 0.45 3.44 3.67 3.58 4.74 4.72 2423.89 99.89 0.52 2.63 0.01 / 0.14Notes:dash indicates that no reading was availableNM = Not MeasuredPID = Photo Ionization DetectorFID = Flame Ionization DetectorAFVR = Aggressive Fluid Vapor Recoveryin Hg = Inches MercuryLNAPL = Light Non‐Aqueous Phase LiquidFPM = Feet Per Minuteppm = parts per millionVAC  = Vacuum °F = degrees Fahrenheitft = feet13:30 ‐ A truck malfunction required a change from the blower exhaust to the pump exhaust. PID/FID battery died; could not charge it.14:45 ‐ Pump was shut off for 20 minutes until 15:05 to prevent overheating.Date/TimeVAC @ Truck (in Hg)Air Flow(at Blower - FPM)FID(at Blower - ppm)Depth to Water/LNAPL (TOC)PID(at Blower - ppm)Temp(at Blower - °F)Vacuum at Surrounding Wells (Inches of Water Column)1 of 1 Table 4a Summary of AFVR Effluent Sample Analytical Results- March 2020 Colonial Pipeline Company Selma Facility Selma, North Carolina Date Collected Time Collected AS-1 (Startup)3/5/2020 8:30 7.91 96.5 1.4 62.3 2.5 18.2 941 2,590 195 147 229 109 1,570 2,840 815 307 4,300 2,020 8,928 AS-2 (End)3/5/2020 15:40 9.93 135 1.02 115 2.35 7.73 538 1,950 104 353 141 158 972 2,700 751 368 2,460 1,250 5,355 Average Concentration 3/5/2020 ----116 --------740 ----------1,271 ------3,380 1,635 7,141 Notes: All concentrations reported in micrograms per cubic meter (µg/m3) VOCs = Volatile Organic Compounds ID = Identification J = Estimated concentration above the method detection limit and below the reporting limit ND = Analyte not detected at or above reporting limit AFVR = Aggressive Fluid Vapor Recovery Total BTEX = the sum of bezene, toluene, ethanol, and xylenes detections Samples were collected in Summa cannisters approximately 30 minutes after beginning AFVR event and 30 minutes prior to completion of AFVR event m&p-xylenesTO-15 2,2,4-TrimethylpentaneTotal BTEXNaphthaleneo-XyleneChloromethaneCyclohexaneDichlorodifluoromethaneEthanoln-Heptanen-HexaneIsopropylbenzene (Cumene)1,3,5-TrimethylbenzeneConstituent Analytical Method Sample ID Toluene1,2,4-Trimethylbenzene4-EthyltolueneBenzeneEthylbenzeneAcetonePage 1 of 1 Table 4b Summary of AFVR Effluent Sample Analytical Results- December 2020 Colonial Pipeline Company Selma Facility Selma, North Carolina DateCollected Time Collected AFVR- START 12/15/2020 9:05 10.0 21.8 3.3 5.6 60.9 19.3 10.8 10.6 5 1.1 7.8 39 1.5 1.6 51.4 18.6 98.8 34.1 243 AFVR- END 12/15/2020 15:30 3,920 12,100 ND ND 28,400 19,000 2,640 3,960 3,750 ND ND 23,200 ND ND 67,500 22,300 83,200 42,900 181,620 Average Concentration 12/15/2020 --1,965 ------14,230 ------------11,619 --------41,649 21,467 90,931 Notes: All concentrations reported in micrograms per cubic meter (µg/m3) VOCs = Volatile Organic Compounds ID = Identification J = Estimated concentration above the method detection limit and below the reporting limit ND = Analyte not detected at or above reporting limit AFVR = Aggressive Fluid Vapor Recovery Total BTEX = the sum of bezene, toluene, ethanol, and xylenes detections Samples were collected in Summa cannisters approximately 30 minutes after beginning AFVR event and 30 minutes prior to completion of AFVR event *It is believed that increases in BTEX concentrations observed in the AFVR- End sample were due to a change in sample location as a result of an equipment malfunction. Analytical Method Sample ID m&p-xylenesTO-15 Total BTEXNaphthaleneo-Xylene2-PropanolTetrachloroetheneTrichloroetheneTrichlorofluoromethane1,3,5-Trimethylbenzene4-EthyltolueneBenzeneEthylbenzeneCyclohexaneToluene1,2,4-Trimethylbenzenen-Heptanen-HexaneConstituent Dichlorodifluoromethanecis-1,2-DichloroethenePage 1 of 1 Table 5a Vapor Phase Mass Removal Calculations- March 2020 Colonial Pipeline Company Selma Facility Selma, North Carolina Site: Colonial Pipeline Selma Facility Extraction Locations: AP-11 Extraction Date: March 5, 2020 Average Air Velocity (FPM) 4,103 Vapor stack diameter (inches) 6 Vapor stack diameter (feet) 0.50 Vapor stack crossectional surface area (ft2)0.196 stack 8" x 12" rectangular Actual cubic feet per minute (ACFM) 805.52 Average Vapor Temperature (oF) [TActual]192.3 (measured at vacuum truck vapor stack) Average Vapor Temperature (oR) [TActual]652.3 (oF +460) Standard Temperature (oR) [TSTP]528 (68o F+460) Average Pressure (in H2O) [PActual]407 (29.92 in Hg = 407 in H2O)* Average Pressure (in H2O) [PSTP]407 (29.92 in Hg = 407 in H2O) Standard Cubic Feet Per Minute (SCFM) 652.02 [ACFM(TSTP /T actual)(PActual/PSTP )] *velocity pressure of vapor discharge when released into atmosphere (STP) Average Benzene concentration (mg/m3)*0.1160 Average BTEX concentration (mg/m3)7.1410 Benzene concentration (lb/ft3)7.2E-09 Total BTEX concentration (lb/ft3)4.5E-07 Average percent benzene in gasoline (% mass) 1.8 Average percent BTEX in gasoline (% mass) 19 Average vapor flow rate (SCFM) 652.02 Average vapor flow rate (SCFM) 652.02 Hours of operation at extraction location 8.0 Hours of operation at extraction location 8.0 Days of operation at extraction location 0.3 Days of operation at extraction location 0.3 Benzene removal rate (pounds/day) 6.80E-03 BTEX removal rate (pounds/day) 4.19E-01 Total mass benzene removed (pounds) 2.27E-03 Total mass BTEX removed (pounds) 1.40E-01 Total mass gasoline removed (pounds) 1.26E-01 Total mass gasoline removed (pounds) 7.34E-01 Total volume gasoline removed (gallons) 2.01E-02 Total volume gasoline removed (gallons) 1.17E-01 Total volume gasoline removed (gallons/day) 6.03E-02 Total volume gasoline removed (gallons/day) 3.52E-01 Notes: Calculations assume Benzene and Total BTEX /gasoline removal = Benzene and Total BTEX ratio in fuel Average percent benzene in gasoline = 1.8% by weight (Risher-Roberts, 1998) Average percent BTEX in gasoline = 19% by weight (Health et al, Journal of Soil Contamination, 1993) ACFM = Actual Cubic Feet per Minute SCFM = Standard Cubic Feet per Minute mg/m3 = milligrams per cubix meter lb/ft3 = pounds per cubic foot ft2 = square feet % = percent H2O = Water T = Temperature oF = degress Fahrenheit oR = degrees Rankine P = Pressure FPM = Feet Per Minute BTEX = sum of benzene, toluene, ethanol, and xylenes detections STP = Standard Temperature and Pressure Conversion from ACFM to SCFM Benzene as Gasoline Total BTEX as Gasoline 1 of 1 Table 5b Vapor Phase Mass Removal Calculations- December 2020 Colonial Pipeline Company Selma Facility Selma, North Carolina Site: Colonial Pipeline Selma Facility Extraction Locations: AP-11 Extraction Date: December 15, 2020 Average Air Velocity (FPM) 2,424 Vapor stack diameter (inches) 6 Vapor stack diameter (feet) 0.50 Vapor stack crossectional surface area (ft2)0.196 stack 8" x 12" rectangular Actual cubic feet per minute (ACFM) 475.89 Average Vapor Temperature (oF) [TActual]99.9 (measured at vacuum truck vapor stack) Average Vapor Temperature (oR) [TActual]559.9 (oF +460) Standard Temperature (oR) [TSTP]528 (68o F+460) Average Pressure (in H2O) [PActual]407 (29.92 in Hg = 407 in H2O)* Average Pressure (in H2O) [PSTP]407 (29.92 in Hg = 407 in H2O) Standard Cubic Feet Per Minute (SCFM) 448.78 [ACFM(TSTP /T actual)(PActual/PSTP )] *velocity pressure of vapor discharge when released into atmosphere (STP) Average Benzene concentration (mg/m3)*1.9650 Average BTEX concentration (mg/m3)90.9310 Benzene concentration (lb/ft3)1.2E-07 Total BTEX concentration (lb/ft3)5.7E-06 Average percent benzene in gasoline (% mass) 1.8 Average percent BTEX in gasoline (% mass) 19 Average vapor flow rate (SCFM) 448.78 Average vapor flow rate (SCFM) 448.78 Hours of operation at extraction location 8.0 Hours of operation at extraction location 8.0 Days of operation at extraction location 0.3 Days of operation at extraction location 0.3 Benzene removal rate (pounds/day) 7.93E-02 BTEX removal rate (pounds/day) 3.67E+00 Total mass benzene removed (pounds) 2.64E-02 Total mass BTEX removed (pounds) 1.22E+00 Total mass gasoline removed (pounds) 1.47E+00 Total mass gasoline removed (pounds) 6.44E+00 Total volume gasoline removed (gallons) 2.34E-01 Total volume gasoline removed (gallons) 1.03E+00 Total volume gasoline removed (gallons/day) 7.03E-01 Total volume gasoline removed (gallons/day) 3.08E+00 Notes: Calculations assume Benzene and Total BTEX /gasoline removal = Benzene and Total BTEX ratio in fuel Average percent benzene in gasoline = 1.8% by weight (Risher-Roberts, 1998) Average percent BTEX in gasoline = 19% by weight (Health et al, Journal of Soil Contamination, 1993) STP = Standard Temperature and Pressure ACFM = Actual Cubic Feet per Minute SCFM = Standard Cubic Feet per Minute mg/m3 = milligrams per cubix meter lb/ft3 = pounds per cubic foot ft2 = square feet % = percent H2O = Water T = Temperature oF = degress Fahrenheit oR = degrees Rankine P = Pressure FPM = Feet Per Minute BTEX = sum of benzene, toluene, ethanol, and xylenes detections STP = Standard Temperature and Pressure Conversion from ACFM to SCFM Benzene as Gasoline Total BTEX as Gasoline 1 of 1 Table 6 Proposed Groundwater Monitoring Program Colonial Pipeline Company Selma Facility Selma, North Carolina Well ID April Groundwater Monitoring Event October Groundwater Monitoring Event AP-1 BTEX, Naphthalene BTEX, Naphthalene AP-2 BTEX, Naphthalene BTEX, Naphthalene AP-2D Gauge Only BTEX, Naphthalene AP-3 BTEX, Naphthalene BTEX, Naphthalene AP-4 BTEX, Naphthalene BTEX, Naphthalene AP-5 BTEX, Naphthalene BTEX, Naphthalene AP-6 Gauge Only BTEX, Naphthalene AP-7 Gauge Only BTEX, Naphthalene AP-8 BTEX, Naphthalene BTEX, Naphthalene AP-9 BTEX, Naphthalene BTEX, Naphthalene AP-10 BTEX, Naphthalene BTEX, Naphthalene AP-11 BTEX, Naphthalene BTEX, Naphthalene Notes: BTEX - Benzene, Toluene, Ethylbenzene, and Total Xylenes BTEX and Naphthalene analyzed by EPA Method 6200B 1 of 1 FIGURES USGS The National Map: National Boundaries Dataset, 3DEP ElevationProgram, Geographic Names Information System, National HydrographyDataset, National Land Cover Database, National Structures Dataset, andNational Transportation Dataset; USGS Global Ecosystems; U.S. CensusBureau TIGER/Line data; USFS Road Data; Natural Earth Data; U.S.Department of State Humanitarian Information Unit; and NOAA NationalCenters for Environmental Information, U.S. Coastal Relief Model. Datarefreshed May, 2020. CHECK BY: AS DRAWN BY: CW DATE: 9/23/2021 SCALE: AS SHOWN CAD NO.: CPC21008 PRJ NO.: CPC21008 FIGURE SITE LOCATION MAP COLONIAL PIPELINE COMPANYSELMA STATION2335 WEST OAK STREETSELMA, NORTH CAROLINA ³ 0 1,000 2,000 Feet 1 SITE LOCATION !A !A"Ò) !A !A !A !A !A !A !A !A!A!>!>!>!>MARATHONPETROLEUMCOMPANY, LLC W.OAKSTACCESSRDSITE BOUNDARY POND TANK SOILSTAGINGAREA OFFICEBUILDING BIT. GRASS EXCAVATION AREA(210' X 20' X 7') MW-11 MW-7 MW-15 MW-16 AP-1 AP-2 AP-2D AP-3 AP-4 AP-5 AP-6 AP-7 AP-8 AP-9 AP-10AP-11 CHECK BY: AS DRAWN BY: CW DATE: 9/23/2021 SCALE: AS SHOWN CAD NO.: CPC21008 PRJ NO.: CPC21008 SITE PLAN COLONIAL PIPELINE COMPANYSELMA STATION2335 WEST OAK STREETSELMA, NORTH CAROLINA !A SHALLOW MONITORING WELL "Ò)DEEP MONITORING WELL !>OFF-SITE MONITORING WELL APPROXIMATE SITE BOUNDARY ³0 50 10025 Feet 2 FIGURE LEGEND APPENDIX A GROUNDWATER SAMPLING LOGS APPENDIX B LABORATORY ANALYTICAL REPORTS The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced,except in its entirety,without the written approval of Pace Analytical Services,LLC. Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) 106 Vantage Point Drive West Columbia,SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Report of Analysis Apex Companies,LLC 10610 Metromont Parkway Suite 206 Charlotte,NC 28269 Attention:Andrew Street Project Name:CPC Selma Project Number:CPC 20104 Task 1 Lot Number:VE28082 Date Completed:06/04/2020 06/04/2020 2:21 PM Approved and released by: Lab Director -Greenville:Lucas Odom Page 1 of 27 PACE ANALYTICAL SERVICES,LLC SC DHEC No:32010001 NELAC No:E87653 NC DENR No:329 NC Field Parameters No:5639 Pace Analytical Services,LLC (formerly Shealy Environmetal Services,Inc.) 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax (803)791-9111 www.pacelabs.com Case Narrative Apex Companies,LLC Lot Number:VE28082 This Report of Analysis contains the analytical result(s)for the sample(s)listed on the Sample Summary following this Case Narrative.The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Sample receipt,sample analysis,and data review have been performed in accordance with the most current approved NELAC standards,the Pace Analytical Services,LLC ("Pace")Quality Assurance Management Plan (QAMP),standard operating procedures (SOPs),and Pace policies.Any exceptions to the NELAC standards,the QAMP,SOPs or policies are qualified on the results page or discussed below. If you have any questions regarding this report please contact the Pace Project Manager listed on the cover page. Page 2 of 27 PACE ANALYTICAL SERVICES, LLC Sample Summary Apex Companies, LLC Lot Number: VE28082 Sample Number Sample ID Matrix Date Sampled Date Received 001 05/27/2020 1155AP-3 Aqueous 05/28/2020 002 05/27/2020 1235AP-9 Aqueous 05/28/2020 003 05/27/2020DUP-1 Aqueous 05/28/2020 004 05/27/2020 1315AP-4 Aqueous 05/28/2020 005 05/27/2020 1345AP-1 Aqueous 05/28/2020 006 05/27/2020EB-1 Aqueous 05/28/2020 007 05/27/2020Trip Blank Aqueous 05/28/2020 008 05/27/2020 1218AP-2 Aqueous 05/28/2020 009 05/27/2020 1248AP-5 Aqueous 05/28/2020 010 05/27/2020 1330AP-8 Aqueous 05/28/2020 011 05/27/2020 1148AP-10 Aqueous 05/28/2020 012 05/27/2020 1408AP-11 Aqueous 05/28/2020 (12 samples) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 3 of 27 PACE ANALYTICAL SERVICES, LLC Detection Summary Apex Companies, LLC Lot Number: VE28082 Sample Sample ID Matrix Parameter Method Result Q Units Page 001 AP-3 Aqueous Benzene SM 6200B-4.0 ug/L 5 004 AP-4 Aqueous Benzene SM 6200B-35 ug/L 8 004 AP-4 Aqueous Ethylbenzene SM 6200B-0.77 ug/L 8 004 AP-4 Aqueous Xylenes (total)SM 6200B-1.9 ug/L 8 008 AP-2 Aqueous Benzene SM 6200B-180 ug/L 12 008 AP-2 Aqueous Ethylbenzene SM 6200B-130 ug/L 12 008 AP-2 Aqueous Toluene SM 6200B-43 ug/L 12 008 AP-2 Aqueous Xylenes (total)SM 6200B-77 ug/L 12 009 AP-5 Aqueous Benzene SM 6200B-42 ug/L 13 009 AP-5 Aqueous Ethylbenzene SM 6200B-80 ug/L 13 009 AP-5 Aqueous Toluene SM 6200B-17 ug/L 13 009 AP-5 Aqueous Xylenes (total)SM 6200B-280 ug/L 13 010 AP-8 Aqueous Benzene SM 6200B-200 ug/L 14 010 AP-8 Aqueous Ethylbenzene SM 6200B-1300 ug/L 14 010 AP-8 Aqueous Xylenes (total)SM 6200B-2000 ug/L 14 011 AP-10 Aqueous Benzene SM 6200B-1200 ug/L 15 011 AP-10 Aqueous Ethylbenzene SM 6200B-310 ug/L 15 011 AP-10 Aqueous Naphthalene SM 6200B-44 ug/L 15 011 AP-10 Aqueous Toluene SM 6200B-59 ug/L 15 011 AP-10 Aqueous Xylenes (total)SM 6200B-330 ug/L 15 012 AP-11 Aqueous Benzene SM 6200B-77 ug/L 16 012 AP-11 Aqueous Ethylbenzene SM 6200B-460 ug/L 16 012 AP-11 Aqueous Naphthalene SM 6200B-170 ug/L 16 012 AP-11 Aqueous Toluene SM 6200B-23 ug/L 16 012 AP-11 Aqueous Xylenes (total)SM 6200B-1700 ug/L 16 (25 detections) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 4 of 27 Description:Matrix: Date Received: Client:Laboratory ID: Date Sampled: Apex Companies, LLC AP-3 VE28082-001 05/27/2020 1155 05/28/2020 Aqueous Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SM 6200B-SM 6200B-2011 1 06/02/2020 0019 JTH 55602 AnalyticalCAS Parameter Number Method Result Q LOQ Units Run Benzene 71-43-2 SM 6200B-4.0 1ug/L0.50 Ethylbenzene 100-41-4 SM 6200B-ND 1ug/L0.50 Naphthalene 91-20-3 SM 6200B-ND 1ug/L0.50 Toluene 108-88-3 SM 6200B-ND 1ug/L0.50 Xylenes (total)1330-20-7 SM 6200B-ND 1ug/L0.50 AcceptanceRun 1 Surrogate Q % Recovery Limits Bromofluorobenzene 108 70-130 1,2-Dichloroethane-d4 73 70-130 Toluene-d8 90 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria H = Out of holding time W = Reported on wet weight basis 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 5 of 27 Description:Matrix: Date Received: Client:Laboratory ID: Date Sampled: Apex Companies, LLC AP-9 VE28082-002 05/27/2020 1235 05/28/2020 Aqueous Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SM 6200B-SM 6200B-2011 1 06/02/2020 0044 JTH 55602 AnalyticalCAS Parameter Number Method Result Q LOQ Units Run Benzene 71-43-2 SM 6200B-ND 1ug/L0.50 Ethylbenzene 100-41-4 SM 6200B-ND 1ug/L0.50 Naphthalene 91-20-3 SM 6200B-ND 1ug/L0.50 Toluene 108-88-3 SM 6200B-ND 1ug/L0.50 Xylenes (total)1330-20-7 SM 6200B-ND 1ug/L0.50 AcceptanceRun 1 Surrogate Q % Recovery Limits Bromofluorobenzene 110 70-130 1,2-Dichloroethane-d4 75 70-130 Toluene-d8 90 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria H = Out of holding time W = Reported on wet weight basis 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 6 of 27 Description:Matrix: Date Received: Client:Laboratory ID: Date Sampled: Apex Companies, LLC DUP-1 VE28082-003 05/27/2020 05/28/2020 Aqueous Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SM 6200B-SM 6200B-2011 1 06/02/2020 0109 JTH 55602 AnalyticalCAS Parameter Number Method Result Q LOQ Units Run Benzene 71-43-2 SM 6200B-ND 1ug/L0.50 Ethylbenzene 100-41-4 SM 6200B-ND 1ug/L0.50 Naphthalene 91-20-3 SM 6200B-ND 1ug/L0.50 Toluene 108-88-3 SM 6200B-ND 1ug/L0.50 Xylenes (total)1330-20-7 SM 6200B-ND 1ug/L0.50 AcceptanceRun 1 Surrogate Q % Recovery Limits Bromofluorobenzene 110 70-130 1,2-Dichloroethane-d4 74 70-130 Toluene-d8 89 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria H = Out of holding time W = Reported on wet weight basis 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 7 of 27 Description:Matrix: Date Received: Client:Laboratory ID: Date Sampled: Apex Companies, LLC AP-4 VE28082-004 05/27/2020 1315 05/28/2020 Aqueous Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SM 6200B-SM 6200B-2011 1 06/02/2020 0134 JTH 55602 AnalyticalCAS Parameter Number Method Result Q LOQ Units Run Benzene 71-43-2 SM 6200B-35 1ug/L0.50 Ethylbenzene 100-41-4 SM 6200B-0.77 1ug/L0.50 Naphthalene 91-20-3 SM 6200B-ND 1ug/L0.50 Toluene 108-88-3 SM 6200B-ND 1ug/L0.50 Xylenes (total)1330-20-7 SM 6200B-1.9 1ug/L0.50 AcceptanceRun 1 Surrogate Q % Recovery Limits Bromofluorobenzene 109 70-130 1,2-Dichloroethane-d4 74 70-130 Toluene-d8 89 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria H = Out of holding time W = Reported on wet weight basis 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 8 of 27 Description:Matrix: Date Received: Client:Laboratory ID: Date Sampled: Apex Companies, LLC AP-1 VE28082-005 05/27/2020 1345 05/28/2020 Aqueous Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SM 6200B-SM 6200B-2011 1 06/02/2020 0158 JTH 55602 AnalyticalCAS Parameter Number Method Result Q LOQ Units Run Benzene 71-43-2 SM 6200B-ND 1ug/L0.50 Ethylbenzene 100-41-4 SM 6200B-ND 1ug/L0.50 Naphthalene 91-20-3 SM 6200B-ND 1ug/L0.50 Toluene 108-88-3 SM 6200B-ND 1ug/L0.50 Xylenes (total)1330-20-7 SM 6200B-ND 1ug/L0.50 AcceptanceRun 1 Surrogate Q % Recovery Limits Bromofluorobenzene 110 70-130 1,2-Dichloroethane-d4 73 70-130 Toluene-d8 89 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria H = Out of holding time W = Reported on wet weight basis 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 9 of 27 Description:Matrix: Date Received: Client:Laboratory ID: Date Sampled: Apex Companies, LLC EB-1 VE28082-006 05/27/2020 05/28/2020 Aqueous Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SM 6200B-SM 6200B-2011 1 06/02/2020 0223 JTH 55602 AnalyticalCAS Parameter Number Method Result Q LOQ Units Run Benzene 71-43-2 SM 6200B-ND 1ug/L0.50 Ethylbenzene 100-41-4 SM 6200B-ND 1ug/L0.50 Naphthalene 91-20-3 SM 6200B-ND 1ug/L0.50 Toluene 108-88-3 SM 6200B-ND 1ug/L0.50 Xylenes (total)1330-20-7 SM 6200B-ND 1ug/L0.50 AcceptanceRun 1 Surrogate Q % Recovery Limits Bromofluorobenzene 109 70-130 1,2-Dichloroethane-d4 72 70-130 Toluene-d8 89 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria H = Out of holding time W = Reported on wet weight basis 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 10 of 27 Description:Matrix: Date Received: Client:Laboratory ID: Date Sampled: Apex Companies, LLC Trip Blank VE28082-007 05/27/2020 05/28/2020 Aqueous Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SM 6200B-SM 6200B-2011 1 06/02/2020 0248 JTH 55602 AnalyticalCAS Parameter Number Method Result Q LOQ Units Run Benzene 71-43-2 SM 6200B-ND 1ug/L0.50 Ethylbenzene 100-41-4 SM 6200B-ND 1ug/L0.50 Toluene 108-88-3 SM 6200B-ND 1ug/L0.50 Xylenes (total)1330-20-7 SM 6200B-ND 1ug/L0.50 AcceptanceRun 1 Surrogate Q % Recovery Limits Bromofluorobenzene 109 70-130 1,2-Dichloroethane-d4 72 70-130 Toluene-d8 88 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria H = Out of holding time W = Reported on wet weight basis 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 11 of 27 Description:Matrix: Date Received: Client:Laboratory ID: Date Sampled: Apex Companies, LLC AP-2 VE28082-008 05/27/2020 1218 05/28/2020 Aqueous Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 2 SM 6200B-SM 6200B-2011 1 06/03/2020 1011 TML 55771 AnalyticalCAS Parameter Number Method Result Q LOQ Units Run Benzene 71-43-2 SM 6200B-180 2ug/L0.50 Ethylbenzene 100-41-4 SM 6200B-130 2ug/L0.50 Toluene 108-88-3 SM 6200B-43 2ug/L0.50 Xylenes (total)1330-20-7 SM 6200B-77 2ug/L0.50 AcceptanceRun 2 Surrogate Q % Recovery Limits Bromofluorobenzene 123 70-130 1,2-Dichloroethane-d4 80 70-130 Toluene-d8 97 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria H = Out of holding time W = Reported on wet weight basis 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 12 of 27 Description:Matrix: Date Received: Client:Laboratory ID: Date Sampled: Apex Companies, LLC AP-5 VE28082-009 05/27/2020 1248 05/28/2020 Aqueous Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SM 6200B-SM 6200B-2011 5 06/02/2020 0313 JTH 55602 AnalyticalCAS Parameter Number Method Result Q LOQ Units Run Benzene 71-43-2 SM 6200B-42 1ug/L2.5 Ethylbenzene 100-41-4 SM 6200B-80 1ug/L2.5 Toluene 108-88-3 SM 6200B-17 1ug/L2.5 Xylenes (total)1330-20-7 SM 6200B-280 1ug/L2.5 AcceptanceRun 1 Surrogate Q % Recovery Limits Bromofluorobenzene 110 70-130 1,2-Dichloroethane-d4 74 70-130 Toluene-d8 87 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria H = Out of holding time W = Reported on wet weight basis 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 13 of 27 Description:Matrix: Date Received: Client:Laboratory ID: Date Sampled: Apex Companies, LLC AP-8 VE28082-010 05/27/2020 1330 05/28/2020 Aqueous Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SM 6200B-SM 6200B-2011 50 06/02/2020 0453 JTH 55602 AnalyticalCAS Parameter Number Method Result Q LOQ Units Run Benzene 71-43-2 SM 6200B-200 1ug/L25 Ethylbenzene 100-41-4 SM 6200B-1300 1ug/L25 Toluene 108-88-3 SM 6200B-ND 1ug/L25 Xylenes (total)1330-20-7 SM 6200B-2000 1ug/L25 AcceptanceRun 1 Surrogate Q % Recovery Limits Bromofluorobenzene 111 70-130 1,2-Dichloroethane-d4 71 70-130 Toluene-d8 87 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria H = Out of holding time W = Reported on wet weight basis 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 14 of 27 Description:Matrix: Date Received: Client:Laboratory ID: Date Sampled: Apex Companies, LLC AP-10 VE28082-011 05/27/2020 1148 05/28/2020 Aqueous Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SM 6200B-SM 6200B-2011 20 06/02/2020 0428 JTH 55602 AnalyticalCAS Parameter Number Method Result Q LOQ Units Run Benzene 71-43-2 SM 6200B-1200 1ug/L10 Ethylbenzene 100-41-4 SM 6200B-310 1ug/L10 Naphthalene 91-20-3 SM 6200B-44 1ug/L10 Toluene 108-88-3 SM 6200B-59 1ug/L10 Xylenes (total)1330-20-7 SM 6200B-330 1ug/L10 AcceptanceRun 1 Surrogate Q % Recovery Limits Bromofluorobenzene 110 70-130 1,2-Dichloroethane-d4 73 70-130 Toluene-d8 88 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria H = Out of holding time W = Reported on wet weight basis 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 15 of 27 Description:Matrix: Date Received: Client:Laboratory ID: Date Sampled: Apex Companies, LLC AP-11 VE28082-012 05/27/2020 1408 05/28/2020 Aqueous Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SM 6200B-SM 6200B-2011 10 06/02/2020 0403 JTH 55602 AnalyticalCAS Parameter Number Method Result Q LOQ Units Run Benzene 71-43-2 SM 6200B-77 1ug/L5.0 Ethylbenzene 100-41-4 SM 6200B-460 1ug/L5.0 Naphthalene 91-20-3 SM 6200B-170 1ug/L5.0 Toluene 108-88-3 SM 6200B-23 1ug/L5.0 Xylenes (total)1330-20-7 SM 6200B-1700 1ug/L5.0 AcceptanceRun 1 Surrogate Q % Recovery Limits Bromofluorobenzene 111 70-130 1,2-Dichloroethane-d4 73 70-130 Toluene-d8 88 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria H = Out of holding time W = Reported on wet weight basis 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 16 of 27 QC Summary 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 17 of 27 Volatile Organic Compounds by GC/MS - MB Batch:Prep Method: Sample ID:VQ55602-001 55602 SM 6200B-2011 Analytical Method:SM 6200B-2011 Matrix:Aqueous Parameter Result Q LOQ Units Analysis DateDil Benzene ND 06/01/2020 22070.50 ug/L1 Ethylbenzene ND 06/01/2020 22070.50 ug/L1 Naphthalene ND 06/01/2020 22070.50 ug/L1 Toluene ND 06/01/2020 22070.50 ug/L1 Xylenes (total)ND 06/01/2020 22070.50 ug/L1 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 108 70-130 1,2-Dichloroethane-d4 76 70-130 Toluene-d8 90 70-130 Note:Calculations are performed before rounding to avoid round-off errors in calculated results LOQ = Limit of Quantitation ND = Not detected at or above the LOQ J = Estimated result < LOQ and > DL N = Recovery is out of criteriaP = The RPD between two GC columns exceeds 40% + = RPD is out of criteria_DL = Detection Limit LOD = Limit of Detection 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 18 of 27 Volatile Organic Compounds by GC/MS - LCS Batch:Prep Method: Sample ID:VQ55602-002 55602 SM 6200B-2011 Analytical Method:SM 6200B-2011 Matrix:Aqueous Parameter Result Q % Rec Spike Amount Analysis Date % Rec LimitDil(ug/L)(ug/L) Benzene 47 06/01/2020 2101955070-1301 Ethylbenzene 48 06/01/2020 2101955070-1301 Naphthalene 45 06/01/2020 2101905050-1401 Toluene 47 06/01/2020 2101945070-1301 Xylenes (total)93 06/01/2020 21019310070-1301 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 88 70-130 1,2-Dichloroethane-d4 90 70-130 Toluene-d8 95 70-130 Note:Calculations are performed before rounding to avoid round-off errors in calculated results LOQ = Limit of Quantitation ND = Not detected at or above the LOQ J = Estimated result < LOQ and > DL N = Recovery is out of criteriaP = The RPD between two GC columns exceeds 40% + = RPD is out of criteria_DL = Detection Limit LOD = Limit of Detection 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 19 of 27 Volatile Organic Compounds by GC/MS - MS Batch:Prep Method: Sample ID:VE28082-009MS 55602 SM 6200B-2011 Analytical Method:SM 6200B-2011 Matrix:Aqueous Parameter Result Q % Rec Spike Amount Analysis Date % Rec Limit Sample Amount Dil(ug/L)(ug/L)(ug/L) Benzene 300 06/02/2020 051810225070-130425 Ethylbenzene 340 06/02/2020 051810225070-130805 Toluene 270 06/02/2020 051810125070-130175 Xylenes (total)770 06/02/2020 05189850070-1302805 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 94 70-130 Toluene-d8 101 70-130 Note:Calculations are performed before rounding to avoid round-off errors in calculated results LOQ = Limit of Quantitation ND = Not detected at or above the LOQ J = Estimated result < LOQ and > DL N = Recovery is out of criteriaP = The RPD between two GC columns exceeds 40% + = RPD is out of criteria_DL = Detection Limit LOD = Limit of Detection 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 20 of 27 Volatile Organic Compounds by GC/MS - MSD Batch:Prep Method: Sample ID:VE28082-009MD 55602 SM 6200B-2011 Analytical Method:SM 6200B-2011 Matrix:Aqueous Parameter Result Q % Rec Spike Amount Analysis Date% RPD % Rec Limit % RPD Limit Sample Amount Dil(ug/L)(ug/L)(ug/L) Benzene 300 06/02/2020 054310225070-1300.73 20425 Ethylbenzene 340 06/02/2020 054310325070-1300.21 20805 Toluene 270 06/02/2020 054310025070-1301.1 20175 Xylenes (total)770 06/02/2020 05439950070-1300.33 202805 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 93 70-130 Toluene-d8 100 70-130 Note:Calculations are performed before rounding to avoid round-off errors in calculated results LOQ = Limit of Quantitation ND = Not detected at or above the LOQ J = Estimated result < LOQ and > DL N = Recovery is out of criteriaP = The RPD between two GC columns exceeds 40% + = RPD is out of criteria_DL = Detection Limit LOD = Limit of Detection 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 21 of 27 Volatile Organic Compounds by GC/MS - MB Batch:Prep Method: Sample ID:VQ55771-001 55771 SM 6200B-2011 Analytical Method:SM 6200B-2011 Matrix:Aqueous Parameter Result Q LOQ Units Analysis DateDil Benzene ND 06/03/2020 09170.50 ug/L1 Ethylbenzene ND 06/03/2020 09170.50 ug/L1 Toluene ND 06/03/2020 09170.50 ug/L1 Xylenes (total)ND 06/03/2020 09170.50 ug/L1 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 121 70-130 1,2-Dichloroethane-d4 77 70-130 Toluene-d8 96 70-130 Note:Calculations are performed before rounding to avoid round-off errors in calculated results LOQ = Limit of Quantitation ND = Not detected at or above the LOQ J = Estimated result < LOQ and > DL N = Recovery is out of criteriaP = The RPD between two GC columns exceeds 40% + = RPD is out of criteria_DL = Detection Limit LOD = Limit of Detection 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 22 of 27 Volatile Organic Compounds by GC/MS - LCS Batch:Prep Method: Sample ID:VQ55771-002 55771 SM 6200B-2011 Analytical Method:SM 6200B-2011 Matrix:Aqueous Parameter Result Q % Rec Spike Amount Analysis Date % Rec LimitDil(ug/L)(ug/L) Benzene 47 06/03/2020 0827955070-1301 Ethylbenzene 48 06/03/2020 0827955070-1301 Toluene 48 06/03/2020 0827965070-1301 Xylenes (total)92 06/03/2020 08279210070-1301 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 90 70-130 1,2-Dichloroethane-d4 93 70-130 Toluene-d8 97 70-130 Note:Calculations are performed before rounding to avoid round-off errors in calculated results LOQ = Limit of Quantitation ND = Not detected at or above the LOQ J = Estimated result < LOQ and > DL N = Recovery is out of criteriaP = The RPD between two GC columns exceeds 40% + = RPD is out of criteria_DL = Detection Limit LOD = Limit of Detection 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 23 of 27 Chain of Custody and Miscellaneous Documents 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 24 of 27 PACE ANALYTICAL SERVICES, LLC 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 25 of 27 PACE ANALYTICAL SERVICES, LLC 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 26 of 27 PACE ANALYTICAL SERVICES, LLC 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Page 27 of 27 #=CL# March 13, 2020 LIMS USE: FR - ANDREW STREET LIMS OBJECT ID: 92468355 92468355 Project: Pace Project No.: RE: Andrew Street Apex Companies 10610 Metromont Parkway Charlotte, NC 28269 CPC19006-001 CPC Selma/19006 Dear Andrew Street: Enclosed are the analytical results for sample(s) received by the laboratory on March 06, 2020. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Angela Baioni angela.baioni@pacelabs.com Project Manager (704)875-9092 Enclosures cc:John McGuire, Apex Companies, LLC Carimar Tavera-Batista, Apex Companies - NC REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 15 #=CP# CERTIFICATIONS Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 Pace Analytical Services National 12065 Lebanon Road, Mt. Juliet, TN 37122 Alabama Certification #: 40660 Alaska Certification 17-026 Arizona Certification #: AZ0612 Arkansas Certification #: 88-0469 California Certification #: 2932 Canada Certification #: 1461.01 Colorado Certification #: TN00003 Connecticut Certification #: PH-0197 DOD Certification: #1461.01 EPA# TN00003 Florida Certification #: E87487 Georgia DW Certification #: 923 Georgia Certification: NELAP Idaho Certification #: TN00003 Illinois Certification #: 200008 Indiana Certification #: C-TN-01 Iowa Certification #: 364 Kansas Certification #: E-10277 Kentucky UST Certification #: 16 Kentucky Certification #: 90010 Louisiana Certification #: AI30792 Louisiana DW Certification #: LA180010 Maine Certification #: TN0002 Maryland Certification #: 324 Massachusetts Certification #: M-TN003 Michigan Certification #: 9958 Minnesota Certification #: 047-999-395 Mississippi Certification #: TN00003 Missouri Certification #: 340 Montana Certification #: CERT0086 Nebraska Certification #: NE-OS-15-05 Nevada Certification #: TN-03-2002-34 New Hampshire Certification #: 2975 New Jersey Certification #: TN002 New Mexico DW Certification New York Certification #: 11742 North Carolina Aquatic Toxicity Certification #: 41 North Carolina Drinking Water Certification #: 21704 North Carolina Environmental Certificate #: 375 North Dakota Certification #: R-140 Ohio VAP Certification #: CL0069 Oklahoma Certification #: 9915 Oregon Certification #: TN200002 Pennsylvania Certification #: 68-02979 Rhode Island Certification #: LAO00356 South Carolina Certification #: 84004 South Dakota Certification Tennessee DW/Chem/Micro Certification #: 2006 Texas Certification #: T 104704245-17-14 Texas Mold Certification #: LAB0152 USDA Soil Permit #: P330-15-00234 Utah Certification #: TN00003 Virginia Certification #: VT2006 Vermont Dept. of Health: ID# VT-2006 Virginia Certification #: 460132 Washington Certification #: C847 West Virginia Certification #: 233 Wisconsin Certification #: 9980939910 Wyoming UST Certification #: via A2LA 2926.01 A2LA-ISO 17025 Certification #: 1461.01 A2LA-ISO 17025 Certification #: 1461.02 AIHA-LAP/LLC EMLAP Certification #:100789 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 15 #=SS# SAMPLE SUMMARY Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 Lab ID Sample ID Matrix Date Collected Date Received 92468355001 AS-1 (Startup)Air 03/05/20 08:30 03/06/20 09:10 92468355002 AS-2 (End)Air 03/05/20 15:40 03/06/20 09:10 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 15 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92468355001 AS-1 (Startup)TO-15 68 PANCAW 92468355002 AS-2 (End)TO-15 68 PANCAW REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 15 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 Sample:AS-1 (Startup)Lab ID:92468355001 Collected:03/05/20 08:30 Received:03/06/20 09:10 Matrix:Air Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: TO-15 Preparation Method: TO-15VOA (MS) TO-15 Acetone 7.91 ug/m3 03/10/20 17:21 67-64-103/10/20 17:212.97 0.0569 1 Allyl chloride <0.626 ug/m3 03/10/20 17:21 107-05-103/10/20 17:210.626 0.0546 1 Benzene 96.5 ug/m3 03/10/20 17:21 71-43-203/10/20 17:210.639 0.0460 1 Benzyl chloride <1.04 ug/m3 03/10/20 17:21 100-44-703/10/20 17:211.04 0.0598 1 Bromodichloromethane <1.34 ug/m3 03/10/20 17:21 75-27-403/10/20 17:211.34 0.0436 1 Bromoform <6.21 ug/m3 03/10/20 17:21 75-25-203/10/20 17:216.21 0.0786 1 Bromomethane <0.776 ug/m3 03/10/20 17:21 74-83-903/10/20 17:210.776 0.0609 1 1,3-Butadiene <4.43 ug/m3 03/10/20 17:21 106-99-003/10/20 17:214.43 0.0563 1 Carbon disulfide <0.622 ug/m3 03/10/20 17:21 75-15-003/10/20 17:210.622 0.0544 1 Carbon tetrachloride <1.26 ug/m3 03/10/20 17:21 56-23-503/10/20 17:211.26 0.0585 1 Chlorobenzene <0.924 ug/m3 03/10/20 17:21 108-90-703/10/20 17:210.924 0.0601 1 Chloroethane <0.528 ug/m3 03/10/20 17:21 75-00-303/10/20 17:210.528 0.0489 1 Chloroform <0.973 ug/m3 03/10/20 17:21 67-66-303/10/20 17:210.973 0.0574 1 Chloromethane 1.35 ug/m3 03/10/20 17:21 74-87-303/10/20 17:210.413 0.0544 1 2-Chlorotoluene <1.03 ug/m3 03/10/20 17:21 95-49-803/10/20 17:211.03 0.0605 1 Cyclohexane 62.3 ug/m3 03/10/20 17:21 110-82-703/10/20 17:210.689 0.0534 1 Dibromochloromethane <1.70 ug/m3 03/10/20 17:21 124-48-103/10/20 17:211.70 0.0494 1 1,2-Dibromoethane (EDB)<1.54 ug/m3 03/10/20 17:21 106-93-403/10/20 17:211.54 0.0185 1 1,2-Dichlorobenzene <1.20 ug/m3 03/10/20 17:21 95-50-103/10/20 17:211.20 0.0603 1 1,3-Dichlorobenzene <1.20 ug/m3 03/10/20 17:21 541-73-103/10/20 17:211.20 0.0597 1 1,4-Dichlorobenzene <1.20 ug/m3 03/10/20 17:21 106-46-703/10/20 17:211.20 0.0557 1 1,2-Dichloroethane <0.810 ug/m3 03/10/20 17:21 107-06-203/10/20 17:210.810 0.0616 1 1,1-Dichloroethane <0.802 ug/m3 03/10/20 17:21 75-34-303/10/20 17:210.802 0.0514 1 1,1-Dichloroethene <0.793 ug/m3 03/10/20 17:21 75-35-403/10/20 17:210.793 0.0490 1 cis-1,2-Dichloroethene <0.793 ug/m3 03/10/20 17:21 156-59-203/10/20 17:210.793 0.0389 1 trans-1,2-Dichloroethene <0.793 ug/m3 03/10/20 17:21 156-60-503/10/20 17:210.793 0.0464 1 1,2-Dichloropropane <0.924 ug/m3 03/10/20 17:21 78-87-503/10/20 17:210.924 0.0599 1 cis-1,3-Dichloropropene <0.908 ug/m3 03/10/20 17:21 10061-01-503/10/20 17:210.908 0.0588 1 trans-1,3-Dichloropropene <0.908 ug/m3 03/10/20 17:21 10061-02-603/10/20 17:210.908 0.0435 1 1,4-Dioxane (p-Dioxane)<0.721 ug/m3 03/10/20 17:21 123-91-103/10/20 17:210.721 0.0554 1 Ethanol 18.2 ug/m3 03/10/20 17:21 64-17-503/10/20 17:211.19 0.0832 1 Ethylbenzene 941 ug/m3 03/11/20 16:07 100-41-403/11/20 16:0743.4 0.0506 50 4-Ethyltoluene 2590 ug/m3 03/11/20 16:07 622-96-803/11/20 16:0749.1 0.0666 50 Trichlorofluoromethane <1.12 ug/m3 03/10/20 17:21 75-69-403/10/20 17:211.12 0.0673 1 Dichlorodifluoromethane 2.50 ug/m3 03/10/20 17:21 75-71-803/10/20 17:210.989 0.0601 1 1,1,2-Trichlorotrifluoroethane <1.53 ug/m3 03/10/20 17:21 76-13-103/10/20 17:211.53 0.0687 1 Dichlorotetrafluoroethane <1.40 ug/m3 03/10/20 17:21 76-14-203/10/20 17:211.40 0.0458 1 n-Heptane 229 ug/m3 03/10/20 17:21 142-82-503/10/20 17:210.818 0.0626 1 Hexachloro-1,3-butadiene <6.73 ug/m3 03/10/20 17:21 87-68-303/10/20 17:216.73 0.0656 1 n-Hexane 109 ug/m3 03/10/20 17:21 110-54-303/10/20 17:210.705 0.0457 1 Isopropylbenzene (Cumene)195 ug/m3 03/10/20 17:21 98-82-803/10/20 17:210.983 0.0563 1 Methylene Chloride <0.694 ug/m3 03/10/20 17:21 75-09-203/10/20 17:210.694 0.0465 1 2-Hexanone <5.11 ug/m3 03/10/20 17:21 591-78-603/10/20 17:215.11 0.0682 1 2-Butanone (MEK)<3.69 ug/m3 03/10/20 17:21 78-93-303/10/20 17:213.69 0.0493 1 4-Methyl-2-pentanone (MIBK)<5.12 ug/m3 03/10/20 17:21 108-10-103/10/20 17:215.12 0.0650 1 Methyl methacrylate <0.819 ug/m3 03/10/20 17:21 80-62-603/10/20 17:210.819 0.0773 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/13/2020 02:03 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 15 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 Sample:AS-1 (Startup)Lab ID:92468355001 Collected:03/05/20 08:30 Received:03/06/20 09:10 Matrix:Air Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: TO-15 Preparation Method: TO-15VOA (MS) TO-15 Methyl-tert-butyl ether <0.721 ug/m3 03/10/20 17:21 1634-04-403/10/20 17:210.721 0.0505 1 Naphthalene 147 ug/m3 03/10/20 17:21 91-20-303/10/20 17:213.30 0.1540 1 2-Propanol <3.07 ug/m3 03/10/20 17:21 67-63-003/10/20 17:213.07 0.0882 1 Propylene <0.689 ug/m3 03/10/20 17:21 115-07-103/10/20 17:210.689 0.0932 1 Styrene <0.851 ug/m3 03/10/20 17:21 100-42-503/10/20 17:210.851 0.0465 1 1,1,2,2-Tetrachloroethane <1.37 ug/m3 03/10/20 17:21 79-34-503/10/20 17:211.37 0.0576 1 Tetrachloroethene <1.36 ug/m3 03/10/20 17:21 127-18-403/10/20 17:211.36 0.0497 1 Tetrahydrofuran <0.590 ug/m3 03/10/20 17:21 109-99-903/10/20 17:210.590 0.0508 1 Toluene 1570 ug/m3 03/11/20 16:07 108-88-303/11/20 16:0737.7 0.0499 50 1,2,4-Trichlorobenzene <4.66 ug/m3 03/10/20 17:21 120-82-103/10/20 17:214.66 0.1480 1 1,1,1-Trichloroethane <1.09 ug/m3 03/10/20 17:21 71-55-603/10/20 17:211.09 0.0665 1 1,1,2-Trichloroethane <1.09 ug/m3 03/10/20 17:21 79-00-503/10/20 17:211.09 0.0287 1 Trichloroethene <1.07 ug/m3 03/10/20 17:21 79-01-603/10/20 17:211.07 0.0545 1 1,2,4-Trimethylbenzene 2840 ug/m3 03/11/20 16:07 95-63-603/11/20 16:0749.1 0.0483 50 1,3,5-Trimethylbenzene 815 ug/m3 03/11/20 16:07 108-67-803/11/20 16:0749.1 0.0631 50 2,2,4-Trimethylpentane 307 ug/m3 03/10/20 17:21 540-84-103/10/20 17:210.934 0.0456 1 Vinyl chloride <0.511 ug/m3 03/10/20 17:21 75-01-403/10/20 17:210.511 0.0457 1 Vinyl bromide <0.875 ug/m3 03/10/20 17:21 593-60-203/10/20 17:210.875 0.0727 1 Vinyl acetate <0.704 ug/m3 03/10/20 17:21 108-05-403/10/20 17:210.704 0.0639 1 m&p-Xylene 4300 ug/m3 03/11/20 16:07 179601-23-103/11/20 16:0786.7 0.0946 50 o-Xylene 2020 ug/m3 03/11/20 16:07 95-47-603/11/20 16:0743.4 0.0633 50 Surrogates 1,4-Dichlorobenzene-d4 (IS)150 %03/10/20 17:21 3855-82-1 ST03/10/20 17:2160.0-140 1 1,4-Dichlorobenzene-d4 (IS)103 %03/11/20 16:07 3855-82-103/11/20 16:0760.0-140 50 Sample:AS-2 (End)Lab ID:92468355002 Collected:03/05/20 15:40 Received:03/06/20 09:10 Matrix:Air Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: TO-15 Preparation Method: TO-15VOA (MS) TO-15 Acetone 9.93 ug/m3 03/10/20 17:59 67-64-103/10/20 17:592.97 0.0569 1 Allyl chloride <0.626 ug/m3 03/10/20 17:59 107-05-103/10/20 17:590.626 0.0546 1 Benzene 135 ug/m3 03/10/20 17:59 71-43-203/10/20 17:590.639 0.0460 1 Benzyl chloride <1.04 ug/m3 03/10/20 17:59 100-44-703/10/20 17:591.04 0.0598 1 Bromodichloromethane <1.34 ug/m3 03/10/20 17:59 75-27-403/10/20 17:591.34 0.0436 1 Bromoform <6.21 ug/m3 03/10/20 17:59 75-25-203/10/20 17:596.21 0.0786 1 Bromomethane <0.776 ug/m3 03/10/20 17:59 74-83-903/10/20 17:590.776 0.0609 1 1,3-Butadiene <4.43 ug/m3 03/10/20 17:59 106-99-003/10/20 17:594.43 0.0563 1 Carbon disulfide <0.622 ug/m3 03/10/20 17:59 75-15-003/10/20 17:590.622 0.0544 1 Carbon tetrachloride <1.26 ug/m3 03/10/20 17:59 56-23-503/10/20 17:591.26 0.0585 1 Chlorobenzene <0.924 ug/m3 03/10/20 17:59 108-90-703/10/20 17:590.924 0.0601 1 Chloroethane <0.528 ug/m3 03/10/20 17:59 75-00-303/10/20 17:590.528 0.0489 1 Chloroform <0.973 ug/m3 03/10/20 17:59 67-66-303/10/20 17:590.973 0.0574 1 Chloromethane 1.02 ug/m3 03/10/20 17:59 74-87-303/10/20 17:590.413 0.0544 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/13/2020 02:03 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 15 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 Sample:AS-2 (End)Lab ID:92468355002 Collected:03/05/20 15:40 Received:03/06/20 09:10 Matrix:Air Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: TO-15 Preparation Method: TO-15VOA (MS) TO-15 2-Chlorotoluene <1.03 ug/m3 03/10/20 17:59 95-49-803/10/20 17:591.03 0.0605 1 Cyclohexane 115 ug/m3 03/10/20 17:59 110-82-703/10/20 17:590.689 0.0534 1 Dibromochloromethane <1.70 ug/m3 03/10/20 17:59 124-48-103/10/20 17:591.70 0.0494 1 1,2-Dibromoethane (EDB)<1.54 ug/m3 03/10/20 17:59 106-93-403/10/20 17:591.54 0.0185 1 1,2-Dichlorobenzene <1.20 ug/m3 03/10/20 17:59 95-50-103/10/20 17:591.20 0.0603 1 1,3-Dichlorobenzene <1.20 ug/m3 03/10/20 17:59 541-73-103/10/20 17:591.20 0.0597 1 1,4-Dichlorobenzene <1.20 ug/m3 03/10/20 17:59 106-46-703/10/20 17:591.20 0.0557 1 1,2-Dichloroethane <0.810 ug/m3 03/10/20 17:59 107-06-203/10/20 17:590.810 0.0616 1 1,1-Dichloroethane <0.802 ug/m3 03/10/20 17:59 75-34-303/10/20 17:590.802 0.0514 1 1,1-Dichloroethene <0.793 ug/m3 03/10/20 17:59 75-35-403/10/20 17:590.793 0.0490 1 cis-1,2-Dichloroethene <0.793 ug/m3 03/10/20 17:59 156-59-203/10/20 17:590.793 0.0389 1 trans-1,2-Dichloroethene <0.793 ug/m3 03/10/20 17:59 156-60-503/10/20 17:590.793 0.0464 1 1,2-Dichloropropane <0.924 ug/m3 03/10/20 17:59 78-87-503/10/20 17:590.924 0.0599 1 cis-1,3-Dichloropropene <0.908 ug/m3 03/10/20 17:59 10061-01-503/10/20 17:590.908 0.0588 1 trans-1,3-Dichloropropene <0.908 ug/m3 03/10/20 17:59 10061-02-603/10/20 17:590.908 0.0435 1 1,4-Dioxane (p-Dioxane)<0.721 ug/m3 03/10/20 17:59 123-91-103/10/20 17:590.721 0.0554 1 Ethanol 7.73 ug/m3 03/10/20 17:59 64-17-503/10/20 17:591.19 0.0832 1 Ethylbenzene 538 ug/m3 03/11/20 16:43 100-41-403/11/20 16:4343.4 0.0506 50 4-Ethyltoluene 1950 ug/m3 03/11/20 16:43 622-96-803/11/20 16:4349.1 0.0666 50 Trichlorofluoromethane <1.12 ug/m3 03/10/20 17:59 75-69-403/10/20 17:591.12 0.0673 1 Dichlorodifluoromethane 2.35 ug/m3 03/10/20 17:59 75-71-803/10/20 17:590.989 0.0601 1 1,1,2-Trichlorotrifluoroethane <1.53 ug/m3 03/10/20 17:59 76-13-103/10/20 17:591.53 0.0687 1 Dichlorotetrafluoroethane <1.40 ug/m3 03/10/20 17:59 76-14-203/10/20 17:591.40 0.0458 1 n-Heptane 141 ug/m3 03/10/20 17:59 142-82-503/10/20 17:590.818 0.0626 1 Hexachloro-1,3-butadiene <6.73 ug/m3 03/10/20 17:59 87-68-303/10/20 17:596.73 0.0656 1 n-Hexane 158 ug/m3 03/10/20 17:59 110-54-303/10/20 17:590.705 0.0457 1 Isopropylbenzene (Cumene)104 ug/m3 03/10/20 17:59 98-82-803/10/20 17:590.983 0.0563 1 Methylene Chloride <0.694 ug/m3 03/10/20 17:59 75-09-203/10/20 17:590.694 0.0465 1 2-Hexanone <5.11 ug/m3 03/10/20 17:59 591-78-603/10/20 17:595.11 0.0682 1 2-Butanone (MEK)<3.69 ug/m3 03/10/20 17:59 78-93-303/10/20 17:593.69 0.0493 1 4-Methyl-2-pentanone (MIBK)<5.12 ug/m3 03/10/20 17:59 108-10-103/10/20 17:595.12 0.0650 1 Methyl methacrylate <0.819 ug/m3 03/10/20 17:59 80-62-603/10/20 17:590.819 0.0773 1 Methyl-tert-butyl ether <0.721 ug/m3 03/10/20 17:59 1634-04-403/10/20 17:590.721 0.0505 1 Naphthalene 353 ug/m3 03/10/20 17:59 91-20-303/10/20 17:593.30 0.1540 1 2-Propanol <3.07 ug/m3 03/10/20 17:59 67-63-003/10/20 17:593.07 0.0882 1 Propylene <0.689 ug/m3 03/10/20 17:59 115-07-103/10/20 17:590.689 0.0932 1 Styrene <0.851 ug/m3 03/10/20 17:59 100-42-503/10/20 17:590.851 0.0465 1 1,1,2,2-Tetrachloroethane <1.37 ug/m3 03/10/20 17:59 79-34-503/10/20 17:591.37 0.0576 1 Tetrachloroethene <1.36 ug/m3 03/10/20 17:59 127-18-403/10/20 17:591.36 0.0497 1 Tetrahydrofuran <0.590 ug/m3 03/10/20 17:59 109-99-903/10/20 17:590.590 0.0508 1 Toluene 972 ug/m3 03/11/20 16:43 108-88-303/11/20 16:4337.7 0.0499 50 1,2,4-Trichlorobenzene <4.66 ug/m3 03/10/20 17:59 120-82-103/10/20 17:594.66 0.1480 1 1,1,1-Trichloroethane <1.09 ug/m3 03/10/20 17:59 71-55-603/10/20 17:591.09 0.0665 1 1,1,2-Trichloroethane <1.09 ug/m3 03/10/20 17:59 79-00-503/10/20 17:591.09 0.0287 1 Trichloroethene <1.07 ug/m3 03/10/20 17:59 79-01-603/10/20 17:591.07 0.0545 1 1,2,4-Trimethylbenzene 2700 ug/m3 03/11/20 16:43 95-63-603/11/20 16:4349.1 0.0483 50 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/13/2020 02:03 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 15 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 Sample:AS-2 (End)Lab ID:92468355002 Collected:03/05/20 15:40 Received:03/06/20 09:10 Matrix:Air Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: TO-15 Preparation Method: TO-15VOA (MS) TO-15 1,3,5-Trimethylbenzene 751 ug/m3 03/11/20 16:43 108-67-803/11/20 16:4349.1 0.0631 50 2,2,4-Trimethylpentane 368 ug/m3 03/10/20 17:59 540-84-103/10/20 17:590.934 0.0456 1 Vinyl chloride <0.511 ug/m3 03/10/20 17:59 75-01-403/10/20 17:590.511 0.0457 1 Vinyl bromide <0.875 ug/m3 03/10/20 17:59 593-60-203/10/20 17:590.875 0.0727 1 Vinyl acetate <0.704 ug/m3 03/10/20 17:59 108-05-403/10/20 17:590.704 0.0639 1 m&p-Xylene 2460 ug/m3 03/11/20 16:43 179601-23-103/11/20 16:4386.7 0.0946 50 o-Xylene 1250 ug/m3 03/11/20 16:43 95-47-603/11/20 16:4343.4 0.0633 50 Surrogates 1,4-Dichlorobenzene-d4 (IS)135 %03/10/20 17:59 3855-82-103/10/20 17:5960.0-140 1 1,4-Dichlorobenzene-d4 (IS)104 %03/11/20 16:43 3855-82-103/11/20 16:4360.0-140 50 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/13/2020 02:03 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 15 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 1441065 TO-15 TO-15 VOA (MS) TO-15 Associated Lab Samples:92468355001, 92468355002 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:R3507393-3 Associated Lab Samples:92468355001, 92468355002 Matrix:Air AnalyzedMDL Acetone ppbv <1.25 1.25 03/10/20 10:150.0569 Allyl chloride ppbv <0.200 0.200 03/10/20 10:150.0546 Benzene ppbv <0.200 0.200 03/10/20 10:150.0460 Benzyl chloride ppbv <0.200 0.200 03/10/20 10:150.0598 Bromodichloromethane ppbv <0.200 0.200 03/10/20 10:150.0436 Bromoform ppbv <0.600 0.600 03/10/20 10:150.0786 Bromomethane ppbv <0.200 0.200 03/10/20 10:150.0609 1,3-Butadiene ppbv <2.00 2.00 03/10/20 10:150.0563 Carbon disulfide ppbv <0.200 0.200 03/10/20 10:150.0544 Carbon tetrachloride ppbv <0.200 0.200 03/10/20 10:150.0585 Chlorobenzene ppbv <0.200 0.200 03/10/20 10:150.0601 Chloroethane ppbv <0.200 0.200 03/10/20 10:150.0489 Chloroform ppbv <0.200 0.200 03/10/20 10:150.0574 Chloromethane ppbv <0.200 0.200 03/10/20 10:150.0544 2-Chlorotoluene ppbv <0.200 0.200 03/10/20 10:150.0605 Cyclohexane ppbv <0.200 0.200 03/10/20 10:150.0534 Dibromochloromethane ppbv <0.200 0.200 03/10/20 10:150.0494 1,2-Dibromoethane (EDB)ppbv <0.200 0.200 03/10/20 10:150.0185 1,2-Dichlorobenzene ppbv <0.200 0.200 03/10/20 10:150.0603 1,3-Dichlorobenzene ppbv <0.200 0.200 03/10/20 10:150.0597 1,4-Dichlorobenzene ppbv <0.200 0.200 03/10/20 10:150.0557 1,2-Dichloroethane ppbv <0.200 0.200 03/10/20 10:150.0616 1,1-Dichloroethane ppbv <0.200 0.200 03/10/20 10:150.0514 1,1-Dichloroethene ppbv <0.200 0.200 03/10/20 10:150.0490 cis-1,2-Dichloroethene ppbv <0.200 0.200 03/10/20 10:150.0389 trans-1,2-Dichloroethene ppbv <0.200 0.200 03/10/20 10:150.0464 1,2-Dichloropropane ppbv <0.200 0.200 03/10/20 10:150.0599 cis-1,3-Dichloropropene ppbv <0.200 0.200 03/10/20 10:150.0588 trans-1,3-Dichloropropene ppbv <0.200 0.200 03/10/20 10:150.0435 1,4-Dioxane (p-Dioxane)ppbv <0.200 0.200 03/10/20 10:150.0554 Trichlorofluoromethane ppbv <0.200 0.200 03/10/20 10:150.0673 Dichlorodifluoromethane ppbv <0.200 0.200 03/10/20 10:150.0601 1,1,2-Trichlorotrifluoroethane ppbv <0.200 0.200 03/10/20 10:150.0687 Dichlorotetrafluoroethane ppbv <0.200 0.200 03/10/20 10:150.0458 n-Heptane ppbv <0.200 0.200 03/10/20 10:150.0626 Hexachloro-1,3-butadiene ppbv <0.630 0.630 03/10/20 10:150.0656 n-Hexane ppbv <0.200 0.200 03/10/20 10:150.0457 Isopropylbenzene (Cumene)ppbv <0.200 0.200 03/10/20 10:150.0563 Methylene Chloride ppbv <0.200 0.200 03/10/20 10:150.0465 2-Hexanone ppbv <1.25 1.25 03/10/20 10:150.0682 2-Butanone (MEK)ppbv <1.25 1.25 03/10/20 10:150.0493 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/13/2020 02:03 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 15 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:R3507393-3 Associated Lab Samples:92468355001, 92468355002 Matrix:Air AnalyzedMDL 4-Methyl-2-pentanone (MIBK)ppbv <1.25 1.25 03/10/20 10:150.0650 Methyl methacrylate ppbv <0.200 0.200 03/10/20 10:150.0773 Methyl-tert-butyl ether ppbv <0.200 0.200 03/10/20 10:150.0505 Naphthalene ppbv <0.630 0.630 03/10/20 10:150.154 2-Propanol ppbv <1.25 1.25 03/10/20 10:150.0882 Propylene ppbv 0.269J 0.400 J03/10/20 10:150.0932 Styrene ppbv <0.200 0.200 03/10/20 10:150.0465 1,1,2,2-Tetrachloroethane ppbv <0.200 0.200 03/10/20 10:150.0576 Tetrachloroethene ppbv <0.200 0.200 03/10/20 10:150.0497 Tetrahydrofuran ppbv <0.200 0.200 03/10/20 10:150.0508 1,2,4-Trichlorobenzene ppbv <0.630 0.630 03/10/20 10:150.148 1,1,1-Trichloroethane ppbv <0.200 0.200 03/10/20 10:150.0665 1,1,2-Trichloroethane ppbv <0.200 0.200 03/10/20 10:150.0287 Trichloroethene ppbv <0.200 0.200 03/10/20 10:150.0545 2,2,4-Trimethylpentane ppbv <0.200 0.200 03/10/20 10:150.0456 Vinyl chloride ppbv <0.200 0.200 03/10/20 10:150.0457 Vinyl bromide ppbv <0.200 0.200 03/10/20 10:150.0727 Vinyl acetate ppbv <0.200 0.200 03/10/20 10:150.0639 Ethanol ppbv <0.630 0.630 03/10/20 10:150.0832 1,4-Dichlorobenzene-d4 (IS)%92.6 60.0-140 03/10/20 10:15 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. R3507393-1LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result R3507393-2 Ethanol ppbv 3.223.75 85.9 55.0-14871.22.67 18.7 25 Propylene ppbv 3.583.75 95.5 64.0-14486.43.24 9.97 25 Dichlorodifluoromethane ppbv 4.083.75 109 64.0-1391033.88 5.03 25 Dichlorotetrafluoroethane ppbv 4.153.75 111 70.0-1301023.84 7.76 25 Chloromethane ppbv 3.973.75 106 70.0-1301033.88 2.29 25 Vinyl chloride ppbv 4.203.75 112 70.0-1301084.04 3.88 25 1,3-Butadiene ppbv 3.793.75 101 70.0-13093.93.52 7.39 25 Bromomethane ppbv 4.033.75 107 70.0-1301114.15 2.93 25 Chloroethane ppbv 4.253.75 113 70.0-13099.23.72 13.3 25 Trichlorofluoromethane ppbv 3.783.75 101 70.0-1301033.85 1.83 25 1,1,2-Trichlorotrifluoroethane ppbv 4.003.75 107 70.0-1301063.96 1.01 25 1,1-Dichloroethene ppbv 4.023.75 107 70.0-1301114.15 3.18 25 1,1-Dichloroethane ppbv 4.083.75 109 70.0-1301084.05 0.738 25 Acetone ppbv 3.903.75 104 70.0-1301063.99 2.28 25 2-Propanol ppbv 3.953.75 105 70.0-1391114.15 4.94 25 Carbon disulfide ppbv 4.183.75 111 70.0-1301094.07 2.67 25 Methylene Chloride ppbv 3.893.75 104 70.0-1301033.87 0.515 25 Methyl-tert-butyl ether ppbv 3.813.75 102 70.0-1301043.90 2.33 25 trans-1,2-Dichloroethene ppbv 4.123.75 110 70.0-1301104.12 0.00 25 n-Hexane ppbv 4.043.75 108 70.0-1301134.23 4.59 25 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/13/2020 02:03 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 15 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. R3507393-1LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result R3507393-2 Vinyl acetate ppbv 4.033.75 107 70.0-1301144.26 5.55 25 2-Butanone (MEK)ppbv 4.333.75 115 70.0-1301144.28 1.16 25 cis-1,2-Dichloroethene ppbv 4.133.75 110 70.0-1301074.02 2.70 25 Chloroform ppbv 4.083.75 109 70.0-1301074.03 1.23 25 Cyclohexane ppbv 3.863.75 103 70.0-1301033.86 0.00 25 1,1,1-Trichloroethane ppbv 3.873.75 103 70.0-13099.53.73 3.68 25 Carbon tetrachloride ppbv 3.913.75 104 70.0-1301043.90 0.256 25 Benzene ppbv 4.133.75 110 70.0-1301033.87 6.50 25 1,2-Dichloroethane ppbv 3.763.75 100 70.0-1301033.87 2.88 25 n-Heptane ppbv 4.273.75 114 70.0-1301144.26 0.234 25 Trichloroethene ppbv 3.853.75 103 70.0-1301043.90 1.29 25 1,2-Dichloropropane ppbv 4.093.75 109 70.0-1301124.21 2.89 25 1,4-Dioxane (p-Dioxane)ppbv 3.723.75 99.2 70.0-1401053.92 5.24 25 Bromodichloromethane ppbv 3.913.75 104 70.0-1301023.84 1.81 25 cis-1,3-Dichloropropene ppbv 4.183.75 111 70.0-1301063.99 4.65 25 4-Methyl-2-pentanone (MIBK)ppbv 3.833.75 102 70.0-1391063.97 3.59 25 trans-1,3-Dichloropropene ppbv 3.933.75 105 70.0-1301084.05 3.01 25 1,1,2-Trichloroethane ppbv 3.893.75 104 70.0-1301033.88 0.257 25 Tetrachloroethene ppbv 3.803.75 101 70.0-1301013.79 0.264 25 2-Hexanone ppbv 3.993.75 106 70.0-1491134.23 5.84 25 Dibromochloromethane ppbv 3.933.75 105 70.0-1301043.89 1.02 25 1,2-Dibromoethane (EDB)ppbv 4.113.75 110 70.0-1301074.01 2.46 25 Chlorobenzene ppbv 3.873.75 103 70.0-1301023.84 0.778 25 Styrene ppbv 3.963.75 106 70.0-1301094.08 2.99 25 Bromoform ppbv 3.973.75 106 70.0-1301033.85 3.07 25 1,1,2,2-Tetrachloroethane ppbv 4.113.75 110 70.0-1301074.02 2.21 25 1,3-Dichlorobenzene ppbv 3.973.75 106 70.0-1301074.01 1.00 25 1,4-Dichlorobenzene ppbv 4.053.75 108 70.0-1301074.00 1.24 25 Benzyl chloride ppbv 4.183.75 111 70.0-1521084.05 3.16 25 1,2-Dichlorobenzene ppbv 4.093.75 109 70.0-1301063.97 2.98 25 1,2,4-Trichlorobenzene ppbv 4.173.75 111 70.0-1601074.03 3.41 25 Hexachloro-1,3-butadiene ppbv 3.683.75 98.1 70.0-15199.23.72 1.08 25 Naphthalene ppbv 4.033.75 107 70.0-1591063.96 1.75 25 Allyl chloride ppbv 4.343.75 116 70.0-1301084.06 6.67 25 2-Chlorotoluene ppbv 3.863.75 103 70.0-1301063.96 2.56 25 Methyl methacrylate ppbv 3.903.75 104 70.0-1301023.84 1.55 25 Tetrahydrofuran ppbv 4.123.75 110 70.0-1371084.06 1.47 25 2,2,4-Trimethylpentane ppbv 4.273.75 114 70.0-1301104.14 3.09 25 Vinyl bromide ppbv 4.083.75 109 70.0-1301043.90 4.51 25 Isopropylbenzene (Cumene)ppbv 4.063.75 108 70.0-1301104.14 1.95 25 1,4-Dichlorobenzene-d4 (IS)%101 60.0-140100 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/13/2020 02:03 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 15 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 1441937 TO-15 TO-15 VOA (MS) TO-15 Associated Lab Samples:92468355001, 92468355002 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:R3507856-3 Associated Lab Samples:92468355001, 92468355002 Matrix:Air AnalyzedMDL Ethylbenzene ppbv <0.200 0.200 03/11/20 09:550.0506 4-Ethyltoluene ppbv <0.200 0.200 03/11/20 09:550.0666 Toluene ppbv <0.200 0.200 03/11/20 09:550.0499 1,2,4-Trimethylbenzene ppbv <0.200 0.200 03/11/20 09:550.0483 1,3,5-Trimethylbenzene ppbv <0.200 0.200 03/11/20 09:550.0631 m&p-Xylene ppbv <0.400 0.400 03/11/20 09:550.0946 o-Xylene ppbv <0.200 0.200 03/11/20 09:550.0633 1,4-Dichlorobenzene-d4 (IS)%99.7 60.0-140 03/11/20 09:55 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. R3507856-1LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result R3507856-2 Toluene ppbv 4.233.75 113 70.0-1301114.15 1.91 25 Ethylbenzene ppbv 4.293.75 114 70.0-1301154.33 0.928 25 m&p-Xylene ppbv 8.807.50 117 70.0-1301168.71 1.03 25 o-Xylene ppbv 4.493.75 120 70.0-1301204.49 0.00 25 4-Ethyltoluene ppbv 4.473.75 119 70.0-1301164.35 2.72 25 1,3,5-Trimethylbenzene ppbv 4.263.75 114 70.0-1301174.37 2.55 25 1,2,4-Trimethylbenzene ppbv 4.403.75 117 70.0-1301164.36 0.913 25 1,4-Dichlorobenzene-d4 (IS)%102 60.0-140103 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/13/2020 02:03 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 12 of 15 #=QL# QUALIFIERS Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES Pace Analytical NationalPAN SAMPLE QUALIFIERS Sample: 92468355001 Volatile Organic Compounds (MS) by Method TO-15 - Surrogate failure due to matrix interference.[1] ANALYTE QUALIFIERS Analyte detected below the reporting limit, therefore result is an estimate. This qualifier is also used for all TICs.J Surrogate recovery was above laboratory control limits. Results may be biased high.ST REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/13/2020 02:03 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 13 of 15 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92468355 CPC19006-001 CPC Selma/19006 Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92468355001 1441065 1441065AS-1 (Startup)TO-15 TO-15 92468355001 1441937 1441937AS-1 (Startup)TO-15 TO-15 92468355002 1441065 1441065AS-2 (End)TO-15 TO-15 92468355002 1441937 1441937AS-2 (End)TO-15 TO-15 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/13/2020 02:03 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 14 of 15 Page 15 of 15 #=CL# November 02, 2020 LIMS USE: FR - ANDREW STREET LIMS OBJECT ID: 92501426 92501426 Project: Pace Project No.: RE: Andrew Street Apex Companies 5900-O Northwoods Business Parkway Charlotte, NC 28269 CPC SELMA/CPC 20104 Dear Andrew Street: Enclosed are the analytical results for sample(s) received by the laboratory on October 21, 2020. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace National - Mt. Juliet • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Angela Baioni angela.baioni@pacelabs.com Project Manager (704)875-9092 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 21 #=CP# CERTIFICATIONS Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Pace Analytical Services National 12065 Lebanon Road, Mt. Juliet, TN 37122 Alabama Certification #: 40660 Alaska Certification 17-026 Arizona Certification #: AZ0612 Arkansas Certification #: 88-0469 California Certification #: 2932 Canada Certification #: 1461.01 Colorado Certification #: TN00003 Connecticut Certification #: PH-0197 DOD Certification: #1461.01 EPA# TN00003 Florida Certification #: E87487 Georgia DW Certification #: 923 Georgia Certification: NELAP Idaho Certification #: TN00003 Illinois Certification #: 200008 Indiana Certification #: C-TN-01 Iowa Certification #: 364 Kansas Certification #: E-10277 Kentucky UST Certification #: 16 Kentucky Certification #: 90010 Louisiana Certification #: AI30792 Louisiana DW Certification #: LA180010 Maine Certification #: TN0002 Maryland Certification #: 324 Massachusetts Certification #: M-TN003 Michigan Certification #: 9958 Minnesota Certification #: 047-999-395 Mississippi Certification #: TN00003 Missouri Certification #: 340 Montana Certification #: CERT0086 Nebraska Certification #: NE-OS-15-05 Nevada Certification #: TN-03-2002-34 New Hampshire Certification #: 2975 New Jersey Certification #: TN002 New Mexico DW Certification New York Certification #: 11742 North Carolina Aquatic Toxicity Certification #: 41 North Carolina Drinking Water Certification #: 21704 North Carolina Environmental Certificate #: 375 North Dakota Certification #: R-140 Ohio VAP Certification #: CL0069 Oklahoma Certification #: 9915 Oregon Certification #: TN200002 Pennsylvania Certification #: 68-02979 Rhode Island Certification #: LAO00356 South Carolina Certification #: 84004 South Dakota Certification Tennessee DW/Chem/Micro Certification #: 2006 Texas Certification #: T 104704245-17-14 Texas Mold Certification #: LAB0152 USDA Soil Permit #: P330-15-00234 Utah Certification #: TN00003 Vermont Dept. of Health: ID# VT-2006 Virginia Certification #: VT2006 Virginia Certification #: 460132 Washington Certification #: C847 West Virginia Certification #: 233 Wisconsin Certification #: 998093910 Wyoming UST Certification #: via A2LA 2926.01 A2LA-ISO 17025 Certification #: 1461.01 A2LA-ISO 17025 Certification #: 1461.02 AIHA-LAP/LLC EMLAP Certification #:100789 Pace Analytical Services Charlotte 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 21 #=SS# SAMPLE SUMMARY Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Lab ID Sample ID Matrix Date Collected Date Received 92501426001 AP-1 Water 10/20/20 10:30 10/21/20 08:15 92501426002 AP-2 Water 10/20/20 12:45 10/21/20 08:15 92501426003 AP-3 Water 10/20/20 13:50 10/21/20 08:15 92501426004 AP-4 Water 10/20/20 14:20 10/21/20 08:15 92501426005 AP-5 Water 10/20/20 13:20 10/21/20 08:15 92501426006 AP-8 Water 10/20/20 14:45 10/21/20 08:15 92501426007 AP-9 Water 10/20/20 11:35 10/21/20 08:15 92501426008 AP-10 Water 10/20/20 11:05 10/21/20 08:15 92501426009 AP-11 Water 10/20/20 15:45 10/21/20 08:15 92501426010 EQUIPMENT BLANK-1 Water 10/20/20 15:50 10/21/20 08:15 92501426011 DUP-1 Water 10/20/20 00:00 10/21/20 08:15 92501426012 TB-1 Water 10/20/20 00:00 10/21/20 08:15 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 21 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92501426001 AP-1 MADEP VPH 6 PANACG EPA 8260D 8 PASI-CCL 92501426002 AP-2 MADEP VPH 6 PANACG EPA 8260D 8 PASI-CSAS 92501426003 AP-3 MADEP VPH 6 PANACG EPA 8260D 8 PASI-CCL 92501426004 AP-4 MADEP VPH 6 PANACG EPA 8260D 8 PASI-CCL 92501426005 AP-5 MADEP VPH 6 PANACG EPA 8260D 8 PASI-CCL 92501426006 AP-8 MADEP VPH 6 PANACG, ADM EPA 8260D 8 PASI-CCL 92501426007 AP-9 MADEP VPH 6 PANACG, ADM EPA 8260D 8 PASI-CCL 92501426008 AP-10 MADEP VPH 6 PANACG EPA 8260D 8 PASI-CCL 92501426009 AP-11 MADEP VPH 6 PANACG, ADM EPA 8260D 8 PASI-CCL 92501426010 EQUIPMENT BLANK-1 MADEP VPH 6 PANACG EPA 8260D 8 PASI-CCL 92501426011 DUP-1 MADEP VPH 6 PANACG, ADM EPA 8260D 8 PASI-CCL 92501426012 TB-1 EPA 8260D 8 PASI-CCL PAN = Pace National - Mt. Juliet PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 21 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Sample:AP-1 Lab ID:92501426001 Collected:10/20/20 10:30 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)270 ug/L 10/29/20 22:0110/29/20 22:0110033.3 1 Aliphatic (C09-C12)<100 ug/L 10/29/20 22:0110/29/20 22:0110033.3 1 Aromatic (C09-C10),Unadjusted 56.2J ug/L 10/29/20 22:01 TPHC9C10A J10/29/20 22:0110033.3 1 Total VPH 326 ug/L 10/29/20 22:01 VPH10/29/20 22:0110033.3 1 Surrogates 2,5-Dibromotoluene (FID)89.9 %10/29/20 22:01 615-59-8FID10/29/20 22:0170.0-130 1 2,5-Dibromotoluene (PID)95.9 %10/29/20 22:01 615-59-8PID10/29/20 22:0170.0-130 1 Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Benzene 179 ug/L 10/26/20 06:25 71-43-22.0 0.30 2 Ethylbenzene <2.0 ug/L 10/26/20 06:25 100-41-42.0 0.51 2 Naphthalene 1.3J ug/L 10/26/20 06:25 91-20-32.0 0.70 2 Toluene 1.4J ug/L 10/26/20 06:25 108-88-32.0 0.49 2 Xylene (Total)<2.0 ug/L 10/26/20 06:25 1330-20-72.0 1.3 2 Surrogates 4-Bromofluorobenzene (S)99 %10/26/20 06:25 460-00-470-130 2 1,2-Dichloroethane-d4 (S)100 %10/26/20 06:25 17060-07-070-130 2 Toluene-d8 (S)100 %10/26/20 06:25 2037-26-570-130 2 Sample:AP-2 Lab ID:92501426002 Collected:10/20/20 12:45 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)2880 ug/L 10/29/20 22:3410/29/20 22:3410033.3 1 Aliphatic (C09-C12)1450 ug/L 10/29/20 22:3410/29/20 22:3410033.3 1 Aromatic (C09-C10),Unadjusted 639 ug/L 10/29/20 22:34 TPHC9C10A10/29/20 22:3410033.3 1 Total VPH 4970 ug/L 10/29/20 22:34 VPH10/29/20 22:3410033.3 1 Surrogates 2,5-Dibromotoluene (FID)94.1 %10/29/20 22:34 615-59-8FID10/29/20 22:3470.0-130 1 2,5-Dibromotoluene (PID)100 %10/29/20 22:34 615-59-8PID10/29/20 22:3470.0-130 1 Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Benzene 498 ug/L 10/22/20 14:06 71-43-25.0 0.75 5 Ethylbenzene 220 ug/L 10/22/20 14:06 100-41-45.0 1.3 5 Naphthalene 49.1 ug/L 10/22/20 14:06 91-20-35.0 1.8 5 Toluene 159 ug/L 10/22/20 14:06 108-88-35.0 1.2 5 Xylene (Total)478 ug/L 10/22/20 14:06 1330-20-75.0 3.2 5 Surrogates 4-Bromofluorobenzene (S)97 %10/22/20 14:06 460-00-470-130 5 1,2-Dichloroethane-d4 (S)104 %10/22/20 14:06 17060-07-070-130 5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 21 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Sample:AP-2 Lab ID:92501426002 Collected:10/20/20 12:45 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Surrogates Toluene-d8 (S)99 %10/22/20 14:06 2037-26-570-130 5 Sample:AP-3 Lab ID:92501426003 Collected:10/20/20 13:50 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)<100 ug/L 10/29/20 23:0710/29/20 23:0710033.3 1 Aliphatic (C09-C12)<100 ug/L 10/29/20 23:0710/29/20 23:0710033.3 1 Aromatic (C09-C10),Unadjusted 39.2J ug/L 10/29/20 23:07 TPHC9C10A J10/29/20 23:0710033.3 1 Total VPH 39.2J ug/L 10/29/20 23:07 VPH J10/29/20 23:0710033.3 1 Surrogates 2,5-Dibromotoluene (FID)89.9 %10/29/20 23:07 615-59-8FID10/29/20 23:0770.0-130 1 2,5-Dibromotoluene (PID)95.7 %10/29/20 23:07 615-59-8PID10/29/20 23:0770.0-130 1 Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Benzene 2.2 ug/L 10/22/20 10:25 71-43-21.0 0.15 1 Ethylbenzene <1.0 ug/L 10/22/20 10:25 100-41-41.0 0.26 1 Naphthalene 2.0 ug/L 10/22/20 10:25 91-20-31.0 0.35 1 Toluene <1.0 ug/L 10/22/20 10:25 108-88-31.0 0.24 1 Xylene (Total)<1.0 ug/L 10/22/20 10:25 1330-20-71.0 0.63 1 Surrogates 4-Bromofluorobenzene (S)99 %10/22/20 10:25 460-00-470-130 1 1,2-Dichloroethane-d4 (S)97 %10/22/20 10:25 17060-07-070-130 1 Toluene-d8 (S)100 %10/22/20 10:25 2037-26-570-130 1 Sample:AP-4 Lab ID:92501426004 Collected:10/20/20 14:20 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)105 ug/L 10/29/20 23:4110/29/20 23:4110033.3 1 Aliphatic (C09-C12)<100 ug/L 10/29/20 23:4110/29/20 23:4110033.3 1 Aromatic (C09-C10),Unadjusted 42.4J ug/L 10/29/20 23:41 TPHC9C10A J10/29/20 23:4110033.3 1 Total VPH 147 ug/L 10/29/20 23:41 VPH10/29/20 23:4110033.3 1 Surrogates 2,5-Dibromotoluene (FID)91.3 %10/29/20 23:41 615-59-8FID10/29/20 23:4170.0-130 1 2,5-Dibromotoluene (PID)97.0 %10/29/20 23:41 615-59-8PID10/29/20 23:4170.0-130 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 21 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Sample:AP-4 Lab ID:92501426004 Collected:10/20/20 14:20 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Benzene 37.7 ug/L 10/22/20 09:48 71-43-21.0 0.15 1 Ethylbenzene 6.0 ug/L 10/22/20 09:48 100-41-41.0 0.26 1 Naphthalene 3.4 ug/L 10/22/20 09:48 91-20-31.0 0.35 1 Toluene <1.0 ug/L 10/22/20 09:48 108-88-31.0 0.24 1 Xylene (Total)8.4 ug/L 10/22/20 09:48 1330-20-71.0 0.63 1 Surrogates 4-Bromofluorobenzene (S)100 %10/22/20 09:48 460-00-470-130 1 1,2-Dichloroethane-d4 (S)99 %10/22/20 09:48 17060-07-070-130 1 Toluene-d8 (S)100 %10/22/20 09:48 2037-26-570-130 1 Sample:AP-5 Lab ID:92501426005 Collected:10/20/20 13:20 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)305 ug/L 10/30/20 00:1410/30/20 00:1410033.3 1 Aliphatic (C09-C12)502 ug/L 10/30/20 00:1410/30/20 00:1410033.3 1 Aromatic (C09-C10),Unadjusted 245 ug/L 10/30/20 00:14 TPHC9C10A10/30/20 00:1410033.3 1 Total VPH 1050 ug/L 10/30/20 00:14 VPH10/30/20 00:1410033.3 1 Surrogates 2,5-Dibromotoluene (FID)95.7 %10/30/20 00:14 615-59-8FID10/30/20 00:1470.0-130 1 2,5-Dibromotoluene (PID)103 %10/30/20 00:14 615-59-8PID10/30/20 00:1470.0-130 1 Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Benzene 41.5 ug/L 10/22/20 10:07 71-43-21.0 0.15 1 Ethylbenzene 96.3 ug/L 10/22/20 10:07 100-41-41.0 0.26 1 Naphthalene 26.4 ug/L 10/22/20 10:07 91-20-31.0 0.35 1 Toluene 3.3 ug/L 10/22/20 10:07 108-88-31.0 0.24 1 Xylene (Total)269 ug/L 10/22/20 10:07 1330-20-71.0 0.63 1 Surrogates 4-Bromofluorobenzene (S)98 %10/22/20 10:07 460-00-470-130 1 1,2-Dichloroethane-d4 (S)99 %10/22/20 10:07 17060-07-070-130 1 Toluene-d8 (S)99 %10/22/20 10:07 2037-26-570-130 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 21 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Sample:AP-8 Lab ID:92501426006 Collected:10/20/20 14:45 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)2790 ug/L 10/30/20 00:4710/30/20 00:4710033.3 1 Aliphatic (C09-C12)8250 ug/L 10/30/20 00:4710/30/20 00:4710033.3 1 Aromatic (C09-C10),Unadjusted 3750 ug/L 10/30/20 13:09 TPHC9C10A10/30/20 13:095001675 Total VPH 11000 ug/L 10/30/20 00:47 VPH10/30/20 00:4710033.3 1 Surrogates 2,5-Dibromotoluene (FID)99.4 %10/30/20 00:47 615-59-8FID10/30/20 00:4770.0-130 1 2,5-Dibromotoluene (FID)89.3 %10/30/20 13:09 615-59-8FID10/30/20 13:0970.0-130 5 2,5-Dibromotoluene (PID)103 %10/30/20 00:47 615-59-8PID10/30/20 00:4770.0-130 1 2,5-Dibromotoluene (PID)95.5 %10/30/20 13:09 615-59-8PID10/30/20 13:0970.0-130 5 Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Benzene 130 ug/L 10/26/20 07:38 71-43-25.0 0.75 5 Ethylbenzene 884 ug/L 10/26/20 07:38 100-41-45.0 1.3 5 Naphthalene 355 ug/L 10/26/20 07:38 91-20-35.0 1.8 5 Toluene <5.0 ug/L 10/26/20 07:38 108-88-35.0 1.2 5 Xylene (Total)963 ug/L 10/26/20 07:38 1330-20-75.0 3.2 5 Surrogates 4-Bromofluorobenzene (S)100 %10/26/20 07:38 460-00-470-130 5 1,2-Dichloroethane-d4 (S)100 %10/26/20 07:38 17060-07-070-130 5 Toluene-d8 (S)98 %10/26/20 07:38 2037-26-570-130 5 Sample:AP-9 Lab ID:92501426007 Collected:10/20/20 11:35 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)<100 ug/L 10/30/20 01:2010/30/20 01:2010033.3 1 Aliphatic (C09-C12)55.9J ug/L 10/30/20 01:20 J10/30/20 01:2010033.3 1 Aromatic (C09-C10),Unadjusted 33.4J ug/L 10/30/20 13:42 TPHC9C10A J10/30/20 13:4210033.3 1 Total VPH 55.9J ug/L 10/30/20 01:20 VPH J10/30/20 01:2010033.3 1 Surrogates 2,5-Dibromotoluene (FID)88.7 %10/30/20 01:20 615-59-8FID10/30/20 01:2070.0-130 1 2,5-Dibromotoluene (FID)90.2 %10/30/20 13:42 615-59-8FID10/30/20 13:4270.0-130 1 2,5-Dibromotoluene (PID)92.4 %10/30/20 01:20 615-59-8PID10/30/20 01:2070.0-130 1 2,5-Dibromotoluene (PID)97.5 %10/30/20 13:42 615-59-8PID10/30/20 13:4270.0-130 1 Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Benzene <1.0 ug/L 10/26/20 05:49 71-43-21.0 0.15 1 Ethylbenzene <1.0 ug/L 10/26/20 05:49 100-41-41.0 0.26 1 Naphthalene <1.0 ug/L 10/26/20 05:49 91-20-31.0 0.35 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 21 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Sample:AP-9 Lab ID:92501426007 Collected:10/20/20 11:35 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Toluene <1.0 ug/L 10/26/20 05:49 108-88-31.0 0.24 1 Xylene (Total)<1.0 ug/L 10/26/20 05:49 1330-20-71.0 0.63 1 Surrogates 4-Bromofluorobenzene (S)99 %10/26/20 05:49 460-00-470-130 1 1,2-Dichloroethane-d4 (S)99 %10/26/20 05:49 17060-07-070-130 1 Toluene-d8 (S)98 %10/26/20 05:49 2037-26-570-130 1 Sample:AP-10 Lab ID:92501426008 Collected:10/20/20 11:05 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)4020 ug/L 10/30/20 01:5310/30/20 01:5310033.3 1 Aliphatic (C09-C12)946 ug/L 10/30/20 01:5310/30/20 01:5310033.3 1 Aromatic (C09-C10),Unadjusted 474 ug/L 10/30/20 01:53 TPHC9C10A10/30/20 01:5310033.3 1 Total VPH 5440 ug/L 10/30/20 01:53 VPH10/30/20 01:5310033.3 1 Surrogates 2,5-Dibromotoluene (FID)95.1 %10/30/20 01:53 615-59-8FID10/30/20 01:5370.0-130 1 2,5-Dibromotoluene (PID)101 %10/30/20 01:53 615-59-8PID10/30/20 01:5370.0-130 1 Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Benzene 1100 ug/L 10/26/20 08:14 71-43-210.0 1.5 10 Ethylbenzene 274 ug/L 10/26/20 08:14 100-41-410.0 2.6 10 Naphthalene 43.6 ug/L 10/26/20 08:14 91-20-310.0 3.5 10 Toluene 25.7 ug/L 10/26/20 08:14 108-88-310.0 2.4 10 Xylene (Total)213 ug/L 10/26/20 08:14 1330-20-710.0 6.3 10 Surrogates 4-Bromofluorobenzene (S)99 %10/26/20 08:14 460-00-470-130 10 1,2-Dichloroethane-d4 (S)101 %10/26/20 08:14 17060-07-070-130 10 Toluene-d8 (S)99 %10/26/20 08:14 2037-26-570-130 10 Sample:AP-11 Lab ID:92501426009 Collected:10/20/20 15:45 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)1010 ug/L 10/30/20 02:2710/30/20 02:2710033.3 1 Aliphatic (C09-C12)6710 ug/L 10/30/20 02:2710/30/20 02:2710033.3 1 Aromatic (C09-C10),Unadjusted 3450 ug/L 10/30/20 14:15 TPHC9C10A10/30/20 14:155001675 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 21 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Sample:AP-11 Lab ID:92501426009 Collected:10/20/20 15:45 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Total VPH 7720 ug/L 10/30/20 02:27 VPH10/30/20 02:2710033.3 1 Surrogates 2,5-Dibromotoluene (FID)95.4 %10/30/20 02:27 615-59-8FID10/30/20 02:2770.0-130 1 2,5-Dibromotoluene (FID)90.2 %10/30/20 14:15 615-59-8FID10/30/20 14:1570.0-130 5 2,5-Dibromotoluene (PID)97.4 %10/30/20 02:27 615-59-8PID10/30/20 02:2770.0-130 1 2,5-Dibromotoluene (PID)96.5 %10/30/20 14:15 615-59-8PID10/30/20 14:1570.0-130 5 Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Benzene 62.5 ug/L 10/26/20 07:02 71-43-24.0 0.60 4 Ethylbenzene 556 ug/L 10/26/20 07:02 100-41-44.0 1.0 4 Naphthalene 250 ug/L 10/26/20 07:02 91-20-34.0 1.4 4 Toluene 62.8 ug/L 10/26/20 07:02 108-88-34.0 0.98 4 Xylene (Total)713 ug/L 10/26/20 07:02 1330-20-74.0 2.5 4 Surrogates 4-Bromofluorobenzene (S)98 %10/26/20 07:02 460-00-470-130 4 1,2-Dichloroethane-d4 (S)101 %10/26/20 07:02 17060-07-070-130 4 Toluene-d8 (S)98 %10/26/20 07:02 2037-26-570-130 4 Sample:EQUIPMENT BLANK-1 Lab ID:92501426010 Collected:10/20/20 15:50 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)<100 ug/L 10/29/20 19:4810/29/20 19:4810033.3 1 Aliphatic (C09-C12)<100 ug/L 10/29/20 19:4810/29/20 19:4810033.3 1 Aromatic (C09-C10),Unadjusted <100 ug/L 10/29/20 19:48 TPHC9C10A10/29/20 19:4810033.3 1 Total VPH <100 ug/L 10/29/20 19:48 VPH10/29/20 19:4810033.3 1 Surrogates 2,5-Dibromotoluene (FID)87.7 %10/29/20 19:48 615-59-8FID10/29/20 19:4870.0-130 1 2,5-Dibromotoluene (PID)92.9 %10/29/20 19:48 615-59-8PID10/29/20 19:4870.0-130 1 Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Benzene <1.0 ug/L 10/22/20 05:49 71-43-21.0 0.15 1 Ethylbenzene <1.0 ug/L 10/22/20 05:49 100-41-41.0 0.26 1 Naphthalene <1.0 ug/L 10/22/20 05:49 91-20-31.0 0.35 1 Toluene <1.0 ug/L 10/22/20 05:49 108-88-31.0 0.24 1 Xylene (Total)<1.0 ug/L 10/22/20 05:49 1330-20-71.0 0.63 1 Surrogates 4-Bromofluorobenzene (S)98 %10/22/20 05:49 460-00-470-130 1 1,2-Dichloroethane-d4 (S)98 %10/22/20 05:49 17060-07-070-130 1 Toluene-d8 (S)100 %10/22/20 05:49 2037-26-570-130 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 21 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Sample:DUP-1 Lab ID:92501426011 Collected:10/20/20 00:00 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)1040 ug/L 10/30/20 03:0010/30/20 03:0010033.3 1 Aliphatic (C09-C12)7050 ug/L 10/30/20 03:0010/30/20 03:0010033.3 1 Aromatic (C09-C10),Unadjusted 3550 ug/L 10/30/20 14:47 TPHC9C10A10/30/20 14:475001675 Total VPH 8090 ug/L 10/30/20 03:00 VPH10/30/20 03:0010033.3 1 Surrogates 2,5-Dibromotoluene (FID)101 %10/30/20 03:00 615-59-8FID10/30/20 03:0070.0-130 1 2,5-Dibromotoluene (FID)90.8 %10/30/20 14:47 615-59-8FID10/30/20 14:4770.0-130 5 2,5-Dibromotoluene (PID)103 %10/30/20 03:00 615-59-8PID10/30/20 03:0070.0-130 1 2,5-Dibromotoluene (PID)96.9 %10/30/20 14:47 615-59-8PID10/30/20 14:4770.0-130 5 Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Benzene 50.6 ug/L 10/26/20 07:20 71-43-25.0 0.75 5 Ethylbenzene 477 ug/L 10/26/20 07:20 100-41-45.0 1.3 5 Naphthalene 234 ug/L 10/26/20 07:20 91-20-35.0 1.8 5 Toluene 34.6 ug/L 10/26/20 07:20 108-88-35.0 1.2 5 Xylene (Total)552 ug/L 10/26/20 07:20 1330-20-75.0 3.2 5 Surrogates 4-Bromofluorobenzene (S)99 %10/26/20 07:20 460-00-470-130 5 1,2-Dichloroethane-d4 (S)99 %10/26/20 07:20 17060-07-070-130 5 Toluene-d8 (S)101 %10/26/20 07:20 2037-26-570-130 5 Sample:TB-1 Lab ID:92501426012 Collected:10/20/20 00:00 Received:10/21/20 08:15 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8260D Pace Analytical Services - Charlotte 8260D MSV Low Level Benzene <1.0 ug/L 10/22/20 05:12 71-43-21.0 0.15 1 Ethylbenzene <1.0 ug/L 10/22/20 05:12 100-41-41.0 0.26 1 Naphthalene <1.0 ug/L 10/22/20 05:12 91-20-31.0 0.35 1 Toluene <1.0 ug/L 10/22/20 05:12 108-88-31.0 0.24 1 Xylene (Total)<1.0 ug/L 10/22/20 05:12 1330-20-71.0 0.63 1 Surrogates 4-Bromofluorobenzene (S)99 %10/22/20 05:12 460-00-470-130 1 1,2-Dichloroethane-d4 (S)97 %10/22/20 05:12 17060-07-070-130 1 Toluene-d8 (S)101 %10/22/20 05:12 2037-26-570-130 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 21 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 1566913 MADEPV MADEP VPH MADEPV Laboratory:Pace National - Mt. Juliet Associated Lab Samples:92501426001, 92501426002, 92501426003, 92501426004, 92501426005, 92501426006, 92501426007, 92501426008, 92501426009, 92501426010, 92501426011 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:R3587451-3 Associated Lab Samples:92501426001, 92501426002, 92501426003, 92501426004, 92501426005, 92501426006, 92501426007, 92501426008, 92501426009, 92501426010, 92501426011 Matrix:Water AnalyzedMDL Aliphatic (C05-C08)ug/L <100 100 10/29/20 14:5933.3 Aliphatic (C09-C12)ug/L <100 100 10/29/20 14:5933.3 Aromatic (C09-C10),Unadjusted ug/L <100 100 10/29/20 14:5933.3 Total VPH ug/L <100 100 10/29/20 14:5933.3 2,5-Dibromotoluene (FID)%83.1 70.0-130 10/29/20 14:59 2,5-Dibromotoluene (PID)%88.6 70.0-130 10/29/20 14:59 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. R3587451-1LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result R3587451-2 Aliphatic (C05-C08)ug/L 10401200 86.7 70.0-13088.31060 1.90 25 Aliphatic (C09-C12)ug/L 13801400 98.6 70.0-1301001400 1.44 25 Aromatic (C09-C10),Unadjusted ug/L 216200 108 70.0-130110220 1.83 25 Total VPH ug/L 26402800 94.3 70.0-13095.72680 1.50 25 2,5-Dibromotoluene (FID)%88.5 70.0-13090.1 2,5-Dibromotoluene (PID)%95.2 70.0-13096.5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 12 of 21 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 1568294 MADEPV MADEP VPH MADEPV Laboratory:Pace National - Mt. Juliet Associated Lab Samples:92501426006, 92501426007, 92501426009, 92501426011 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:R3587687-3 Associated Lab Samples:92501426006, 92501426007, 92501426009, 92501426011 Matrix:Water AnalyzedMDL Aromatic (C09-C10),Unadjusted ug/L <100 100 10/30/20 11:1533.3 2,5-Dibromotoluene (FID)%86.5 70.0-130 10/30/20 11:15 2,5-Dibromotoluene (PID)%92.7 70.0-130 10/30/20 11:15 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. R3587687-1LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result R3587687-2 Aromatic (C09-C10),Unadjusted ug/L 206200 103 70.0-130103206 0.00 25 2,5-Dibromotoluene (FID)%87.9 70.0-13091.1 2,5-Dibromotoluene (PID)%97.6 70.0-130101 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 13 of 21 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 574844 EPA 8260D EPA 8260D 8260D MSV Low Level Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92501426003, 92501426004, 92501426005, 92501426010, 92501426012 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3043246 Associated Lab Samples:92501426003, 92501426004, 92501426005, 92501426010, 92501426012 Matrix:Water AnalyzedMDL Benzene ug/L <1.0 1.0 10/22/20 04:360.15 Ethylbenzene ug/L <1.0 1.0 10/22/20 04:360.26 Naphthalene ug/L <1.0 1.0 10/22/20 04:360.35 Toluene ug/L <1.0 1.0 10/22/20 04:360.24 Xylene (Total)ug/L <1.0 1.0 10/22/20 04:360.63 1,2-Dichloroethane-d4 (S)%96 70-130 10/22/20 04:36 4-Bromofluorobenzene (S)%100 70-130 10/22/20 04:36 Toluene-d8 (S)%102 70-130 10/22/20 04:36 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3043247LABORATORY CONTROL SAMPLE: LCSSpike Benzene ug/L 52.350 105 70-130 Ethylbenzene ug/L 52.150 104 70-130 Naphthalene ug/L 57.950 116 70-133 Toluene ug/L 52.450 105 70-130 Xylene (Total)ug/L 162150 108 70-130 1,2-Dichloroethane-d4 (S)%95 70-130 4-Bromofluorobenzene (S)%102 70-130 Toluene-d8 (S)%100 70-130 Parameter Units MS Result % Rec Limits Qual% RecConc. 3043248MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92501397003 3043249 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Benzene ug/L 20 105 67-150113 8 3020ND21.0 22.7 Ethylbenzene ug/L 20 104 68-143112 8 3020ND20.7 22.4 Naphthalene ug/L M120-421 57-150-414 7 302010622.0 23.5 Toluene ug/L 20 103 47-157111 8 3020ND20.6 22.2 Xylene (Total)ug/L 60 106 66-145114 7 3060ND63.7 68.7 1,2-Dichloroethane-d4 (S)%96 70-13095 4-Bromofluorobenzene (S)%99 70-13099 Toluene-d8 (S)%98 70-13099 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 14 of 21 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 574852 EPA 8260D EPA 8260D 8260D MSV Low Level Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92501426002 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3043261 Associated Lab Samples:92501426002 Matrix:Water AnalyzedMDL Benzene ug/L <1.0 1.0 10/22/20 12:560.15 Ethylbenzene ug/L <1.0 1.0 10/22/20 12:560.26 Naphthalene ug/L <1.0 1.0 10/22/20 12:560.35 Toluene ug/L <1.0 1.0 10/22/20 12:560.24 Xylene (Total)ug/L <1.0 1.0 10/22/20 12:560.63 1,2-Dichloroethane-d4 (S)%105 70-130 10/22/20 12:56 4-Bromofluorobenzene (S)%96 70-130 10/22/20 12:56 Toluene-d8 (S)%102 70-130 10/22/20 12:56 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3043262LABORATORY CONTROL SAMPLE: LCSSpike Benzene ug/L 52.350 105 70-130 Ethylbenzene ug/L 51.250 102 70-130 Naphthalene ug/L 51.550 103 70-133 Toluene ug/L 50.650 101 70-130 Xylene (Total)ug/L 155150 103 70-130 1,2-Dichloroethane-d4 (S)%103 70-130 4-Bromofluorobenzene (S)%103 70-130 Toluene-d8 (S)%99 70-130 Parameter Units MS Result % Rec Limits Qual% RecConc. 3043263MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92501426002 3043264 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Benzene ug/L 100 124 67-15078 8 30100498622576 Ethylbenzene ug/L 100 118 68-143100 5 30100220338320 Naphthalene ug/L 100 94 57-150101 4 3010049.1 143 150 Toluene ug/L 100 110 47-15793 7 30100159269252 Xylene (Total)ug/L 300 112 66-14596 6 30300478813766 1,2-Dichloroethane-d4 (S)%116 70-130103 4-Bromofluorobenzene (S)%100 70-13096 Toluene-d8 (S)%99 70-13099 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 15 of 21 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 575501 EPA 8260D EPA 8260D 8260D MSV Low Level Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92501426001, 92501426006, 92501426007, 92501426008, 92501426009, 92501426011 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3046744 Associated Lab Samples:92501426001, 92501426006, 92501426007, 92501426008, 92501426009, 92501426011 Matrix:Water AnalyzedMDL Benzene ug/L <1.0 1.0 10/26/20 03:060.15 Ethylbenzene ug/L <1.0 1.0 10/26/20 03:060.26 Naphthalene ug/L <1.0 1.0 10/26/20 03:060.35 Toluene ug/L <1.0 1.0 10/26/20 03:060.24 Xylene (Total)ug/L <1.0 1.0 10/26/20 03:060.63 1,2-Dichloroethane-d4 (S)%99 70-130 10/26/20 03:06 4-Bromofluorobenzene (S)%101 70-130 10/26/20 03:06 Toluene-d8 (S)%100 70-130 10/26/20 03:06 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3046745LABORATORY CONTROL SAMPLE: LCSSpike Benzene ug/L 49.650 99 70-130 Ethylbenzene ug/L 50.050 100 70-130 Naphthalene ug/L 53.450 107 70-133 Toluene ug/L 50.650 101 70-130 Xylene (Total)ug/L 157150 105 70-130 1,2-Dichloroethane-d4 (S)%102 70-130 4-Bromofluorobenzene (S)%101 70-130 Toluene-d8 (S)%99 70-130 Parameter Units MS Result % Rec Limits Qual% RecConc. 3046746MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92501584010 3046747 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Benzene ug/L 20 123 67-150115 7 30201.0 U 24.6 22.9 Ethylbenzene ug/L 20 122 68-143113 8 30201.0 U 24.4 22.6 Naphthalene ug/L 20 117 57-150111 5 30201.0 U 23.4 22.2 Toluene ug/L 20 120 47-157113 6 30201.0 U 24.0 22.6 Xylene (Total)ug/L 60 122 66-145113 8 30601.0 U 73.1 67.8 1,2-Dichloroethane-d4 (S)%96 70-13094 4-Bromofluorobenzene (S)%102 70-13099 Toluene-d8 (S)%100 70-13099 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 16 of 21 #=QL# QUALIFIERS Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS Analyte detected below the reporting limit, therefore result is an estimate. This qualifier is also used for all TICs.J Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.M1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 17 of 21 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92501426 CPC SELMA/CPC 20104 Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92501426001 1566913 1566913AP-1 MADEPV MADEP VPH 92501426002 1566913 1566913AP-2 MADEPV MADEP VPH 92501426003 1566913 1566913AP-3 MADEPV MADEP VPH 92501426004 1566913 1566913AP-4 MADEPV MADEP VPH 92501426005 1566913 1566913AP-5 MADEPV MADEP VPH 92501426006 1566913 1566913AP-8 MADEPV MADEP VPH 92501426006 1568294 1568294AP-8 MADEPV MADEP VPH 92501426007 1566913 1566913AP-9 MADEPV MADEP VPH 92501426007 1568294 1568294AP-9 MADEPV MADEP VPH 92501426008 1566913 1566913AP-10 MADEPV MADEP VPH 92501426009 1566913 1566913AP-11 MADEPV MADEP VPH 92501426009 1568294 1568294AP-11 MADEPV MADEP VPH 92501426010 1566913 1566913EQUIPMENT BLANK-1 MADEPV MADEP VPH 92501426011 1566913 1566913DUP-1 MADEPV MADEP VPH 92501426011 1568294 1568294DUP-1 MADEPV MADEP VPH 92501426001 575501AP-1 EPA 8260D 92501426002 574852AP-2 EPA 8260D 92501426003 574844AP-3 EPA 8260D 92501426004 574844AP-4 EPA 8260D 92501426005 574844AP-5 EPA 8260D 92501426006 575501AP-8 EPA 8260D 92501426007 575501AP-9 EPA 8260D 92501426008 575501AP-10 EPA 8260D 92501426009 575501AP-11 EPA 8260D 92501426010 574844EQUIPMENT BLANK-1 EPA 8260D 92501426011 575501DUP-1 EPA 8260D 92501426012 574844TB-1 EPA 8260D REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/02/2020 08:27 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 18 of 21 Page 19 of 21 Page 20 of 21 Page 21 of 21 #=CL# December 31, 2020 LIMS USE: FR - ANDREW STREET LIMS OBJECT ID: 92512081 92512081 Project: Pace Project No.: RE: Andrew Street Apex Companies 5900-O Northwoods Business Parkway Charlotte, NC 28269 CPC 20104 Dear Andrew Street: Enclosed are the analytical results for sample(s) received by the laboratory on December 16, 2020. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services - Minneapolis If you have any questions concerning this report, please feel free to contact me. Sincerely, Angela Baioni angela.baioni@pacelabs.com Project Manager (704)875-9092 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 16 #=CP# CERTIFICATIONS Pace Project No.: Project: 92512081 CPC 20104 Pace Analytical Services - Minneapolis MN 1700 Elm Street SE, Minneapolis, MN 55414 1800 Elm Street SE, Minneapolis, MN 55414--Satellite Air Lab A2LA Certification #: 2926.01* Alabama Certification #: 40770 Alaska Contaminated Sites Certification #: 17-009* Alaska DW Certification #: MN00064 Arizona Certification #: AZ0014* Arkansas DW Certification #: MN00064 Arkansas WW Certification #: 88-0680 California Certification #: 2929 Colorado Certification #: MN00064 Connecticut Certification #: PH-0256 EPA Region 8+Wyoming DW Certification #: via MN 027- 053-137 Florida Certification #: E87605* Georgia Certification #: 959 Hawaii Certification #: MN00064 Idaho Certification #: MN00064 Illinois Certification #: 200011 Indiana Certification #: C-MN-01 Iowa Certification #: 368 Kansas Certification #: E-10167 Kentucky DW Certification #: 90062 Kentucky WW Certification #: 90062 Louisiana DEQ Certification #: AI-03086* Louisiana DW Certification #: MN00064 Maine Certification #: MN00064* Maryland Certification #: 322 Massachusetts DWP Certification #: via MN 027-053-137 Michigan Certification #: 9909 Minnesota Certification #: 027-053-137* Minnesota Dept of Ag Certifcation #: via MN 027-053-137 Minnesota Petrofund Certification #: 1240* Mississippi Certification #: MN00064 Missouri Certification #: 10100 Montana Certification #: CERT0092 Nebraska Certification #: NE-OS-18-06 Nevada Certification #: MN00064 New Hampshire Certification #: 2081* New Jersey Certification #: MN002 New York Certification #: 11647* North Carolina DW Certification #: 27700 North Carolina WW Certification #: 530 North Dakota Certification #: R-036 Ohio DW Certification #: 41244 Ohio VAP Certification #: CL101 Oklahoma Certification #: 9507* Oregon Primary Certification #: MN300001 Oregon Secondary Certification #: MN200001* Pennsylvania Certification #: 68-00563* Puerto Rico Certification #: MN00064 South Carolina Certification #:74003001 Tennessee Certification #: TN02818 Texas Certification #: T104704192* Utah Certification #: MN00064* Vermont Certification #: VT-027053137 Virginia Certification #: 460163* Washington Certification #: C486* West Virginia DEP Certification #: 382 West Virginia DW Certification #: 9952 C Wisconsin Certification #: 999407970 Wyoming UST Certification #: via A2LA 2926.01 USDA Permit #: P330-19-00208 *Please Note: Applicable air certifications are denoted with an asterisk (*). REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 16 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92512081 CPC 20104 Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92512081001 AFVR - START TO-15 58 PASI-MDR1 92512081002 AFVR - END TO-15 58 PASI-MDR1 PASI-M = Pace Analytical Services - Minneapolis REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 16 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92512081 CPC 20104 Sample:AFVR - START Lab ID:92512081001 Collected:12/15/20 09:05 Received:12/16/20 09:08 Matrix:Air Parameters Results Units DF Prepared Analyzed CAS No.QualReport Limit Analytical Method: TO-15 Pace Analytical Services - Minneapolis TO15 MSV AIR Acetone ND ug/m3 12/30/20 21:18 67-64-18.1 1.34 Benzene 10.0 ug/m3 12/30/20 21:18 71-43-20.44 1.34 Bromodichloromethane ND ug/m3 12/30/20 21:18 75-27-41.8 1.34 Bromoform ND ug/m3 12/30/20 21:18 75-25-27.0 1.34 Bromomethane ND ug/m3 12/30/20 21:18 74-83-91.1 1.34 1,3-Butadiene ND ug/m3 12/30/20 21:18 106-99-00.60 1.34 2-Butanone (MEK)ND ug/m3 12/30/20 21:18 78-93-34.0 1.34 Carbon disulfide ND ug/m3 12/30/20 21:18 75-15-00.85 1.34 Carbon tetrachloride ND ug/m3 12/30/20 21:18 56-23-51.7 1.34 Chlorobenzene ND ug/m3 12/30/20 21:18 108-90-71.3 1.34 Chloroethane ND ug/m3 12/30/20 21:18 75-00-30.72 1.34 Chloroform ND ug/m3 12/30/20 21:18 67-66-30.66 1.34 Chloromethane ND ug/m3 12/30/20 21:18 74-87-30.56 1.34 Cyclohexane 21.8 ug/m3 12/30/20 21:18 110-82-72.3 1.34 Dibromochloromethane ND ug/m3 12/30/20 21:18 124-48-12.3 1.34 1,2-Dibromoethane (EDB)ND ug/m3 12/30/20 21:18 106-93-41.0 1.34 1,2-Dichlorobenzene ND ug/m3 12/30/20 21:18 95-50-11.6 1.34 1,3-Dichlorobenzene ND ug/m3 12/30/20 21:18 541-73-11.6 1.34 1,4-Dichlorobenzene ND ug/m3 12/30/20 21:18 106-46-74.1 1.34 Dichlorodifluoromethane 3.3 ug/m3 12/30/20 21:18 75-71-81.4 1.34 1,1-Dichloroethane ND ug/m3 12/30/20 21:18 75-34-31.1 1.34 1,2-Dichloroethane ND ug/m3 12/30/20 21:18 107-06-21.1 1.34 1,1-Dichloroethene ND ug/m3 12/30/20 21:18 75-35-41.1 1.34 cis-1,2-Dichloroethene 5.6 ug/m3 12/30/20 21:18 156-59-21.1 1.34 trans-1,2-Dichloroethene ND ug/m3 12/30/20 21:18 156-60-51.1 1.34 1,2-Dichloropropane ND ug/m3 12/30/20 21:18 78-87-51.3 1.34 cis-1,3-Dichloropropene ND ug/m3 12/30/20 21:18 10061-01-51.2 1.34 trans-1,3-Dichloropropene ND ug/m3 12/30/20 21:18 10061-02-61.2 1.34 Dichlorotetrafluoroethane ND ug/m3 12/30/20 21:18 76-14-21.9 1.34 Ethyl acetate ND ug/m3 12/30/20 21:18 141-78-60.98 1.34 Ethylbenzene 60.9 ug/m3 12/30/20 21:18 100-41-41.2 1.34 4-Ethyltoluene 19.3 ug/m3 12/30/20 21:18 622-96-83.4 1.34 n-Heptane 10.8 ug/m3 12/30/20 21:18 142-82-51.1 1.34 Hexachloro-1,3-butadiene ND ug/m3 12/30/20 21:18 87-68-37.3 1.34 n-Hexane 10.6 ug/m3 12/30/20 21:18 110-54-30.96 1.34 2-Hexanone ND ug/m3 12/30/20 21:18 591-78-65.6 1.34 Methylene Chloride ND ug/m3 12/30/20 21:18 75-09-24.7 1.34 4-Methyl-2-pentanone (MIBK)ND ug/m3 12/30/20 21:18 108-10-15.6 1.34 Methyl-tert-butyl ether ND ug/m3 12/30/20 21:18 1634-04-44.9 1.34 Naphthalene 4.7 ug/m3 12/30/20 21:18 91-20-33.6 1.34 Propylene 1.1 ug/m3 12/30/20 21:18 115-07-10.47 1.34 Styrene ND ug/m3 12/30/20 21:18 100-42-51.2 1.34 1,1,2,2-Tetrachloroethane ND ug/m3 12/30/20 21:18 79-34-50.94 1.34 Tetrachloroethene 7.8 ug/m3 12/30/20 21:18 127-18-40.92 1.34 Tetrahydrofuran ND ug/m3 12/30/20 21:18 109-99-90.80 1.34 Toluene 38.8 ug/m3 12/30/20 21:18 108-88-31.0 1.34 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/31/2020 04:39 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 16 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92512081 CPC 20104 Sample:AFVR - START Lab ID:92512081001 Collected:12/15/20 09:05 Received:12/16/20 09:08 Matrix:Air Parameters Results Units DF Prepared Analyzed CAS No.QualReport Limit Analytical Method: TO-15 Pace Analytical Services - Minneapolis TO15 MSV AIR 1,2,4-Trichlorobenzene ND ug/m3 12/30/20 21:18 120-82-110.1 1.34 1,1,1-Trichloroethane ND ug/m3 12/30/20 21:18 71-55-61.5 1.34 1,1,2-Trichloroethane ND ug/m3 12/30/20 21:18 79-00-50.74 1.34 Trichloroethene 1.5 ug/m3 12/30/20 21:18 79-01-60.73 1.34 Trichlorofluoromethane 1.6 ug/m3 12/30/20 21:18 75-69-41.5 1.34 1,1,2-Trichlorotrifluoroethane ND ug/m3 12/30/20 21:18 76-13-12.1 1.34 1,2,4-Trimethylbenzene 51.4 ug/m3 12/30/20 21:18 95-63-61.3 1.34 1,3,5-Trimethylbenzene 18.6 ug/m3 12/30/20 21:18 108-67-81.3 1.34 Vinyl acetate ND ug/m3 12/30/20 21:18 108-05-40.96 1.34 Vinyl chloride ND ug/m3 12/30/20 21:18 75-01-40.35 1.34 m&p-Xylene 98.8 ug/m3 12/30/20 21:18 179601-23-12.4 1.34 o-Xylene 34.1 ug/m3 12/30/20 21:18 95-47-61.2 1.34 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/31/2020 04:39 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 16 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92512081 CPC 20104 Sample:AFVR - END Lab ID:92512081002 Collected:12/15/20 15:30 Received:12/16/20 09:08 Matrix:Air Parameters Results Units DF Prepared Analyzed CAS No.QualReport Limit Analytical Method: TO-15 Pace Analytical Services - Minneapolis TO15 MSV AIR Acetone ND ug/m3 12/31/20 00:22 67-64-177701286 Benzene 3920 ug/m3 12/31/20 00:22 71-43-24181286 Bromodichloromethane ND ug/m3 12/31/20 00:22 75-27-417501286 Bromoform ND ug/m3 12/31/20 00:22 75-25-267501286 Bromomethane ND ug/m3 12/31/20 00:22 74-83-910101286 1,3-Butadiene ND ug/m3 12/31/20 00:22 106-99-05791286 2-Butanone (MEK)ND ug/m3 12/31/20 00:22 78-93-338601286 Carbon disulfide ND ug/m3 12/31/20 00:22 75-15-08141286 Carbon tetrachloride ND ug/m3 12/31/20 00:22 56-23-516501286 Chlorobenzene ND ug/m3 12/31/20 00:22 108-90-712001286 Chloroethane ND ug/m3 12/31/20 00:22 75-00-36901286 Chloroform ND ug/m3 12/31/20 00:22 67-66-36381286 Chloromethane ND ug/m3 12/31/20 00:22 74-87-35401286 Cyclohexane 12100 ug/m3 12/31/20 00:22 110-82-722501286 Dibromochloromethane ND ug/m3 12/31/20 00:22 124-48-122301286 1,2-Dibromoethane (EDB)ND ug/m3 12/31/20 00:22 106-93-410001286 1,2-Dichlorobenzene ND ug/m3 12/31/20 00:22 95-50-115701286 1,3-Dichlorobenzene ND ug/m3 12/31/20 00:22 541-73-115701286 1,4-Dichlorobenzene ND ug/m3 12/31/20 00:22 106-46-739401286 Dichlorodifluoromethane ND ug/m3 12/31/20 00:22 75-71-813001286 1,1-Dichloroethane ND ug/m3 12/31/20 00:22 75-34-310601286 1,2-Dichloroethane ND ug/m3 12/31/20 00:22 107-06-210601286 1,1-Dichloroethene ND ug/m3 12/31/20 00:22 75-35-410401286 cis-1,2-Dichloroethene ND ug/m3 12/31/20 00:22 156-59-210401286 trans-1,2-Dichloroethene ND ug/m3 12/31/20 00:22 156-60-510401286 1,2-Dichloropropane ND ug/m3 12/31/20 00:22 78-87-512101286 cis-1,3-Dichloropropene ND ug/m3 12/31/20 00:22 10061-01-511901286 trans-1,3-Dichloropropene ND ug/m3 12/31/20 00:22 10061-02-611901286 Dichlorotetrafluoroethane ND ug/m3 12/31/20 00:22 76-14-218301286 Ethyl acetate ND ug/m3 12/31/20 00:22 141-78-69431286 Ethylbenzene 28400 ug/m3 12/31/20 00:22 100-41-411401286 4-Ethyltoluene 19000 ug/m3 12/31/20 00:22 622-96-832201286 n-Heptane 2640 ug/m3 12/31/20 00:22 142-82-510701286 Hexachloro-1,3-butadiene ND ug/m3 12/31/20 00:22 87-68-369701286 n-Hexane 3960 ug/m3 12/31/20 00:22 110-54-39211286 2-Hexanone ND ug/m3 12/31/20 00:22 591-78-653501286 Methylene Chloride ND ug/m3 12/31/20 00:22 75-09-245401286 4-Methyl-2-pentanone (MIBK)ND ug/m3 12/31/20 00:22 108-10-153501286 Methyl-tert-butyl ether ND ug/m3 12/31/20 00:22 1634-04-447101286 Naphthalene 3750 ug/m3 12/31/20 00:22 91-20-334201286 Propylene ND ug/m3 12/31/20 00:22 115-07-14501286 Styrene ND ug/m3 12/31/20 00:22 100-42-511101286 1,1,2,2-Tetrachloroethane ND ug/m3 12/31/20 00:22 79-34-58981286 Tetrachloroethene ND ug/m3 12/31/20 00:22 127-18-48861286 Tetrahydrofuran ND ug/m3 12/31/20 00:22 109-99-97721286 Toluene 23200 ug/m3 12/31/20 00:22 108-88-39851286 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/31/2020 04:39 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 16 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92512081 CPC 20104 Sample:AFVR - END Lab ID:92512081002 Collected:12/15/20 15:30 Received:12/16/20 09:08 Matrix:Air Parameters Results Units DF Prepared Analyzed CAS No.QualReport Limit Analytical Method: TO-15 Pace Analytical Services - Minneapolis TO15 MSV AIR 1,2,4-Trichlorobenzene ND ug/m3 12/31/20 00:22 120-82-197001286 1,1,1-Trichloroethane ND ug/m3 12/31/20 00:22 71-55-614301286 1,1,2-Trichloroethane ND ug/m3 12/31/20 00:22 79-00-57141286 Trichloroethene ND ug/m3 12/31/20 00:22 79-01-67021286 Trichlorofluoromethane ND ug/m3 12/31/20 00:22 75-69-414701286 1,1,2-Trichlorotrifluoroethane ND ug/m3 12/31/20 00:22 76-13-120101286 1,2,4-Trimethylbenzene 67500 ug/m3 12/31/20 00:22 95-63-612901286 1,3,5-Trimethylbenzene 22300 ug/m3 12/31/20 00:22 108-67-812901286 Vinyl acetate ND ug/m3 12/31/20 00:22 108-05-49211286 Vinyl chloride ND ug/m3 12/31/20 00:22 75-01-43341286 m&p-Xylene 83200 ug/m3 12/31/20 00:22 179601-23-122801286 o-Xylene 42900 ug/m3 12/31/20 00:22 95-47-611401286 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/31/2020 04:39 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 16 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92512081 CPC 20104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 718310 TO-15 TO-15 TO15 MSV AIR Low Level Laboratory:Pace Analytical Services - Minneapolis Associated Lab Samples:92512081001, 92512081002 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3832568 Associated Lab Samples:92512081001, 92512081002 Matrix:Air Analyzed 1,1,1-Trichloroethane ug/m3 ND 1.1 12/30/20 08:44 1,1,2,2-Tetrachloroethane ug/m3 ND 0.70 12/30/20 08:44 1,1,2-Trichloroethane ug/m3 ND 0.56 12/30/20 08:44 1,1,2-Trichlorotrifluoroethane ug/m3 ND 1.6 12/30/20 08:44 1,1-Dichloroethane ug/m3 ND 0.82 12/30/20 08:44 1,1-Dichloroethene ug/m3 ND 0.81 12/30/20 08:44 1,2,4-Trichlorobenzene ug/m3 ND 7.5 12/30/20 08:44 1,2,4-Trimethylbenzene ug/m3 ND 1.0 12/30/20 08:44 1,2-Dibromoethane (EDB)ug/m3 ND 0.78 12/30/20 08:44 1,2-Dichlorobenzene ug/m3 ND 1.2 12/30/20 08:44 1,2-Dichloroethane ug/m3 ND 0.82 MN12/30/20 08:44 1,2-Dichloropropane ug/m3 ND 0.94 12/30/20 08:44 1,3,5-Trimethylbenzene ug/m3 ND 1.0 12/30/20 08:44 1,3-Butadiene ug/m3 ND 0.45 12/30/20 08:44 1,3-Dichlorobenzene ug/m3 ND 1.2 12/30/20 08:44 1,4-Dichlorobenzene ug/m3 ND 3.1 12/30/20 08:44 2-Butanone (MEK)ug/m3 ND 3.0 12/30/20 08:44 2-Hexanone ug/m3 ND 4.2 12/30/20 08:44 4-Ethyltoluene ug/m3 ND 2.5 12/30/20 08:44 4-Methyl-2-pentanone (MIBK)ug/m3 ND 4.2 12/30/20 08:44 Acetone ug/m3 ND 6.0 12/30/20 08:44 Benzene ug/m3 ND 0.32 12/30/20 08:44 Bromodichloromethane ug/m3 ND 1.4 12/30/20 08:44 Bromoform ug/m3 ND 5.2 12/30/20 08:44 Bromomethane ug/m3 ND 0.79 12/30/20 08:44 Carbon disulfide ug/m3 ND 0.63 12/30/20 08:44 Carbon tetrachloride ug/m3 ND 1.3 12/30/20 08:44 Chlorobenzene ug/m3 ND 0.94 12/30/20 08:44 Chloroethane ug/m3 ND 0.54 12/30/20 08:44 Chloroform ug/m3 ND 0.50 12/30/20 08:44 Chloromethane ug/m3 ND 0.42 12/30/20 08:44 cis-1,2-Dichloroethene ug/m3 ND 0.81 12/30/20 08:44 cis-1,3-Dichloropropene ug/m3 ND 0.92 12/30/20 08:44 Cyclohexane ug/m3 ND 1.8 12/30/20 08:44 Dibromochloromethane ug/m3 ND 1.7 12/30/20 08:44 Dichlorodifluoromethane ug/m3 ND 1.0 12/30/20 08:44 Dichlorotetrafluoroethane ug/m3 ND 1.4 12/30/20 08:44 Ethyl acetate ug/m3 ND 0.73 12/30/20 08:44 Ethylbenzene ug/m3 ND 0.88 12/30/20 08:44 Hexachloro-1,3-butadiene ug/m3 ND 5.4 12/30/20 08:44 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/31/2020 04:39 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 16 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92512081 CPC 20104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3832568 Associated Lab Samples:92512081001, 92512081002 Matrix:Air Analyzed m&p-Xylene ug/m3 ND 1.8 12/30/20 08:44 Methyl-tert-butyl ether ug/m3 ND 3.7 12/30/20 08:44 Methylene Chloride ug/m3 ND 3.5 12/30/20 08:44 n-Heptane ug/m3 ND 0.83 12/30/20 08:44 n-Hexane ug/m3 ND 0.72 12/30/20 08:44 Naphthalene ug/m3 ND 2.7 12/30/20 08:44 o-Xylene ug/m3 ND 0.88 12/30/20 08:44 Propylene ug/m3 ND 0.35 12/30/20 08:44 Styrene ug/m3 ND 0.87 12/30/20 08:44 Tetrachloroethene ug/m3 ND 0.69 12/30/20 08:44 Tetrahydrofuran ug/m3 ND 0.60 12/30/20 08:44 Toluene ug/m3 ND 0.77 12/30/20 08:44 trans-1,2-Dichloroethene ug/m3 ND 0.81 12/30/20 08:44 trans-1,3-Dichloropropene ug/m3 ND 0.92 12/30/20 08:44 Trichloroethene ug/m3 ND 0.55 12/30/20 08:44 Trichlorofluoromethane ug/m3 ND 1.1 12/30/20 08:44 Vinyl acetate ug/m3 ND 0.72 12/30/20 08:44 Vinyl chloride ug/m3 ND 0.26 12/30/20 08:44 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3832569LABORATORY CONTROL SAMPLE: LCSSpike 1,1,1-Trichloroethane ug/m3 67.357 118 70-130 1,1,2,2-Tetrachloroethane ug/m3 94.3 CH71.9 131 70-132 1,1,2-Trichloroethane ug/m3 65.357.3 114 70-133 1,1,2-Trichlorotrifluoroethane ug/m3 84.480.3 105 70-130 1,1-Dichloroethane ug/m3 52.442.7 123 70-130 1,1-Dichloroethene ug/m3 42.341.4 102 69-137 1,2,4-Trichlorobenzene ug/m3 129156 83 70-130 1,2,4-Trimethylbenzene ug/m3 62.951.5 122 70-137 1,2-Dibromoethane (EDB)ug/m3 92.380.3 115 70-138 1,2-Dichlorobenzene ug/m3 76.863.1 122 70-136 1,2-Dichloroethane ug/m3 52.642.4 124 70-130 1,2-Dichloropropane ug/m3 57.848.6 119 70-132 1,3,5-Trimethylbenzene ug/m3 62.351.6 121 70-136 1,3-Butadiene ug/m3 25.823.3 111 67-139 1,3-Dichlorobenzene ug/m3 70.363.4 111 70-138 1,4-Dichlorobenzene ug/m3 66.563.4 105 70-145 2-Butanone (MEK)ug/m3 35.831.4 114 61-130 2-Hexanone ug/m3 53.842.8 126 70-138 4-Ethyltoluene ug/m3 65.352.4 125 70-142 4-Methyl-2-pentanone (MIBK)ug/m3 53.543.6 123 70-134 Acetone ug/m3 121126 96 59-137 Benzene ug/m3 39.533.5 118 70-133 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/31/2020 04:39 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 16 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92512081 CPC 20104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3832569LABORATORY CONTROL SAMPLE: LCSSpike Bromodichloromethane ug/m3 84.271.5 118 70-130 Bromoform ug/m3 120110 109 60-140 Bromomethane ug/m3 42.941.3 104 70-131 Carbon disulfide ug/m3 35.533.3 106 70-130 Carbon tetrachloride ug/m3 76.166.2 115 70-133 Chlorobenzene ug/m3 60.248.3 125 70-131 Chloroethane ug/m3 29.728.1 106 70-141 Chloroform ug/m3 64.251.1 126 70-130 Chloromethane ug/m3 23.121.9 105 64-137 cis-1,2-Dichloroethene ug/m3 49.341.6 118 70-132 cis-1,3-Dichloropropene ug/m3 57.447.7 120 70-138 Cyclohexane ug/m3 35.436.7 96 70-133 Dibromochloromethane ug/m3 11290.7 123 70-139 Dichlorodifluoromethane ug/m3 55.751.6 108 70-130 Dichlorotetrafluoroethane ug/m3 78.572.7 108 65-133 Ethyl acetate ug/m3 47.638.6 123 70-135 Ethylbenzene ug/m3 54.445.6 119 70-142 Hexachloro-1,3-butadiene ug/m3 106112 95 70-134 m&p-Xylene ug/m3 10991.2 120 70-141 Methyl-tert-butyl ether ug/m3 46.438.4 121 70-131 Methylene Chloride ug/m3 213182 117 69-130 n-Heptane ug/m3 43.043.6 98 70-130 n-Hexane ug/m3 34.637.6 92 70-131 Naphthalene ug/m3 45.657.7 79 63-130 o-Xylene ug/m3 55.545.5 122 70-135 Propylene ug/m3 18.418.2 101 63-139 Styrene ug/m3 58.6 CH44.9 130 70-143 Tetrachloroethene ug/m3 80.971 114 70-136 Tetrahydrofuran ug/m3 36.231.5 115 70-137 Toluene ug/m3 45.939.5 116 70-136 trans-1,2-Dichloroethene ug/m3 49.942.2 118 70-132 trans-1,3-Dichloropropene ug/m3 57.747.7 121 70-139 Trichloroethene ug/m3 63.556.3 113 70-132 Trichlorofluoromethane ug/m3 59.859.7 100 65-136 Vinyl acetate ug/m3 43.234.5 125 66-140 Vinyl chloride ug/m3 28.526.7 107 68-141 Parameter Units Dup Result QualifiersRPDResult 10542923001 3833815SAMPLE DUPLICATE: 1,1,1-Trichloroethane ug/m3 ND<0.25 1,1,2,2-Tetrachloroethane ug/m3 ND<0.29 1,1,2-Trichloroethane ug/m3 ND<0.23 1,1,2-Trichlorotrifluoroethane ug/m3 ND<0.31 1,1-Dichloroethane ug/m3 ND<0.17 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/31/2020 04:39 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 16 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92512081 CPC 20104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result QualifiersRPDResult 10542923001 3833815SAMPLE DUPLICATE: 1,1-Dichloroethene ug/m3 ND<0.17 1,2,4-Trichlorobenzene ug/m3 ND<5.2 1,2,4-Trimethylbenzene ug/m3 .5J0.41J 1,2-Dibromoethane (EDB)ug/m3 ND<0.31 1,2-Dichlorobenzene ug/m3 ND<0.97 1,2-Dichloroethane ug/m3 ND<0.18 1,2-Dichloropropane ug/m3 ND<0.24 1,3,5-Trimethylbenzene ug/m3 ND<0.27 1,3-Butadiene ug/m3 ND<0.15 1,3-Dichlorobenzene ug/m3 ND<1.1 1,4-Dichlorobenzene ug/m3 ND<1.3 2-Butanone (MEK)ug/m3 1.9J1.9J 2-Hexanone ug/m3 ND<1.1 4-Ethyltoluene ug/m3 ND<0.29 4-Methyl-2-pentanone (MIBK)ug/m3 ND<0.15 Acetone ug/m3 9.5 910.4 Benzene ug/m3 1.6 51.7 Bromodichloromethane ug/m3 ND<0.30 Bromoform ug/m3 ND<1.2 Bromomethane ug/m3 ND<0.24 Carbon disulfide ug/m3 ND<0.14 Carbon tetrachloride ug/m3 ND<0.29 Chlorobenzene ug/m3 ND<0.22 Chloroethane ug/m3 ND<0.18 Chloroform ug/m3 ND<0.20 Chloromethane ug/m3 ND<0.10 cis-1,2-Dichloroethene ug/m3 ND<0.19 cis-1,3-Dichloropropene ug/m3 ND<0.22 Cyclohexane ug/m3 .83J0.88J Dibromochloromethane ug/m3 ND<0.44 Dichlorodifluoromethane ug/m3 3.1 63.2 Dichlorotetrafluoroethane ug/m3 ND<0.32 Ethyl acetate ug/m3 ND<0.16 Ethylbenzene ug/m3 .49J0.50J Hexachloro-1,3-butadiene ug/m3 ND<2.6 m&p-Xylene ug/m3 1.8J1.9J Methyl-tert-butyl ether ug/m3 ND<0.18 Methylene Chloride ug/m3 ND<1.6 n-Heptane ug/m3 ND1.1J n-Hexane ug/m3 2.0 61.9 Naphthalene ug/m3 ND<2.5 o-Xylene ug/m3 .67J0.67J Propylene ug/m3 ND<0.32 Styrene ug/m3 ND<0.36 Tetrachloroethene ug/m3 ND<0.34 Tetrahydrofuran ug/m3 ND<0.18 Toluene ug/m3 3.9 44.0 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/31/2020 04:39 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 16 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92512081 CPC 20104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result QualifiersRPDResult 10542923001 3833815SAMPLE DUPLICATE: trans-1,2-Dichloroethene ug/m3 ND<0.22 trans-1,3-Dichloropropene ug/m3 ND<0.89 Trichloroethene ug/m3 ND<0.28 Trichlorofluoromethane ug/m3 ND1.7 Vinyl acetate ug/m3 ND<0.15 Vinyl chloride ug/m3 ND<0.11 Parameter Units Dup Result QualifiersRPDResult 10543047001 3833816SAMPLE DUPLICATE: 1,1,1-Trichloroethane ug/m3 NDND 1,1,2,2-Tetrachloroethane ug/m3 NDND 1,1,2-Trichloroethane ug/m3 NDND 1,1,2-Trichlorotrifluoroethane ug/m3 .48JND 1,1-Dichloroethane ug/m3 NDND 1,1-Dichloroethene ug/m3 NDND 1,2,4-Trichlorobenzene ug/m3 NDND 1,2,4-Trimethylbenzene ug/m3 2.5 22.5 1,2-Dibromoethane (EDB)ug/m3 NDND 1,2-Dichlorobenzene ug/m3 NDND 1,2-Dichloroethane ug/m3 NDND 1,2-Dichloropropane ug/m3 NDND 1,3,5-Trimethylbenzene ug/m3 .62JND 1,3-Butadiene ug/m3 ND25.7 1,3-Dichlorobenzene ug/m3 NDND 1,4-Dichlorobenzene ug/m3 NDND 2-Butanone (MEK)ug/m3 27.6 127.9 2-Hexanone ug/m3 3.1JND 4-Ethyltoluene ug/m3 1.1JND 4-Methyl-2-pentanone (MIBK)ug/m3 NDND Acetone ug/m3 82.9 385.3 Benzene ug/m3 5.5 05.5 Bromodichloromethane ug/m3 NDND Bromoform ug/m3 NDND Bromomethane ug/m3 NDND Carbon disulfide ug/m3 3.0 13.0 Carbon tetrachloride ug/m3 NDND Chlorobenzene ug/m3 NDND Chloroethane ug/m3 NDND Chloroform ug/m3 NDND Chloromethane ug/m3 NDND cis-1,2-Dichloroethene ug/m3 NDND cis-1,3-Dichloropropene ug/m3 NDND Cyclohexane ug/m3 2.1JND Dibromochloromethane ug/m3 NDND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/31/2020 04:39 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 12 of 16 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92512081 CPC 20104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result QualifiersRPDResult 10543047001 3833816SAMPLE DUPLICATE: Dichlorodifluoromethane ug/m3 3.1 43.0 Dichlorotetrafluoroethane ug/m3 NDND Ethyl acetate ug/m3 NDND Ethylbenzene ug/m3 3.9 03.9 Hexachloro-1,3-butadiene ug/m3 NDND m&p-Xylene ug/m3 7.3 56.9 Methyl-tert-butyl ether ug/m3 NDND Methylene Chloride ug/m3 NDND n-Heptane ug/m3 5.1 75.4 n-Hexane ug/m3 3.3 03.3 Naphthalene ug/m3 6.4 46.1 o-Xylene ug/m3 3.0 12.9 Propylene ug/m3 76.6 277.8 Styrene ug/m3 2.8 CH62.6 Tetrachloroethene ug/m3 NDND Tetrahydrofuran ug/m3 NDND Toluene ug/m3 9.4 59.8 trans-1,2-Dichloroethene ug/m3 NDND trans-1,3-Dichloropropene ug/m3 NDND Trichloroethene ug/m3 NDND Trichlorofluoromethane ug/m3 1.4JND Vinyl acetate ug/m3 NDND Vinyl chloride ug/m3 NDND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/31/2020 04:39 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 13 of 16 #=QL# QUALIFIERS Pace Project No.: Project: 92512081 CPC 20104 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. SAMPLE QUALIFIERS Sample: 92512081001 Analysis performed at 1800 Elm Street.[1] Sample: 92512081002 Analysis performed at 1800 Elm Street.[1] ANALYTE QUALIFIERS The continuing calibration for this compound is outside of Pace Analytical acceptance limits. The results may be biased high.CH The reporting limit has been raised in accordance with Minnesota Statutes 4740.2100 Subpart 8. C, D. Reporting Limit Evaluation Rule.MN REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/31/2020 04:39 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 14 of 16 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92512081 CPC 20104 Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92512081001 718310AFVR - START TO-15 92512081002 718310AFVR - END TO-15 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/31/2020 04:39 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 15 of 16 Page 16 of 16 APPENDIX C TANK CONVERSION TABLE APPENDIX D WASTE MANIFEST