HomeMy WebLinkAboutFA-29604_48735_CA_UST-61_20221017
UST-61 24-Hour Release and UST Leak Reporting Form.
For Releases
in NC
This form should be completed and submitted to the UST Section’s regional office following a known or suspected release from an underground storage tank (UST) system. This form is required to be submitted within 24 hours of discovery of a known or
suspected release
(DWM USE ONLY) Incident # ________ Risk (H,I,L,U)_______ Received On ________ Received By ________ Reported by (circle one): Phone, Fax or Report Region _______
Suspected Contamination ? (Y/N) _Y______ Confirmed GW Contamination ? (Y/N) _N___ Confirmed Soil Contamination ?(Y/N) _Y___
Samples Taken?(Y/N) ___Y___ Free Product? (Y/N) ___N__ If Yes, State Greatest Thickness ______________
Facility ID Number _None
Date Leak Discovered _6-2022___
Comm/Non-Commercial ? Non-Com
Reg/Non-regulated? _ Non-Reg_____
INCIDENT DESCRIPTION
Incident Name: A&M Farms
Address: 543 Johnson Farm Road County: Harnett
City/Town: Lillington Zip Code: 27546 Regional Office (circle one): Asheville, Mooresville, Fayetteville, Raleigh, Washington, Wilmington, Winston-Salem
Latitude (decimal degrees): N 35.4143027 Longitude (decimal degrees) : W -78.7589350 Obtained by:
Briefly describe suspected or confirmed release: (including but not limited to: nature of release, date of release, amount
of release, amount of free product present and recovery efforts, initial responses conducted, impacts to receptors) GPS
Topographic map
X GIS Address matching
Other
Unknown
Describe location:
HOW RELEASE WAS DISCOVERED (Release Code)
(Check one)
Release Detection Equipment or Methods
During UST Closure/Removal PXhase II ESA for Property Transfer
Visual /Odor
Water in Tank
Water Supply Well Contamination
SX oil Contamination
Groundwater Contamination
Surface Water Contamination Other (specify) ___________
SOURCE OF CONTAMINATION
Source of Release (Check primary source) Cause of Release (Check primary cause) Type of Release (Check one) Product Type Released (Check primary product type released)
X Tank
Piping
Dispenser
Submersible Turbine Pump
Delivery Problem
Spill Bucket
Other
Unknown
Definitions presented on reverse
Spill
Overfill
X Corrosion
Physical/Mechanical Damage
Install Problem
Other
Unknown
Definitions presented on reverse
PetroleumX
Non-Petroleum
Both
Location
(Check one)
Facility
Residence
X Other
X Gasoline /
Diesel/
Kerosene
Heating Oil
Other Petroleum
Products
Metals
Other Inorganics
Other Organics
Diesel/Veg. Oil
Blend
Vegetable Oil 100%
E10 – E20
E21 – E84
E85 – E99
Ethanol 100%
E01 – E09
Ownership
1. Municipal 2. Military 3. Unknown 4. Private 5. Federal 6. County 7. State Operation Type 1. Public Service 2. Agricultural 3. Residential 4. Education /Relig. 5. Industrial
6.
Commercial
7.
Mining
UST Form 61 (02/19) Page 1 of 2
A Phase II Environmental Site Assessment (ESA) was completed for the USTs during June 2022 for sale of the property il
Three test borings and one temporary well were completed . Soil samples from one boring showed GRO at a level
with East Coast Environmental PA to remove the tanks and complete an Initial Abatement Action Report during
.September and October 2022.
of 172 mg/kg. Groundwater sample had low detections all below 15A NCAC 2L 0202 . A&M Farms contracted
Two 550-gallon farm USTs (gasoline and diesel) were discovered while completing a Phase I ESA.
IMPACT ON DRINKING WATER SUPPLIES
Water Supply Wells Affected? 1. Yes 2. No 3. Unknown
Number of Water Supply Wells Affected __________________
Water Supply Wells Contaminated: (Include Users Names, Addresses and Phone Numbers. Attach additional sheet if necessary) 1. 2. 3.
UST SYSTEM OWNER UST Owner/Company:A& M Farms
Point of Contact: Glen Johnson Address: P.O. Box 69
City: Lillington State: NC Zip Code: 27546 Telephone Number
UST SYSTEM OPERATOR
UST Operator/Company: Unknown/deceased Address:
City: State: Zip Code: Telephone Number
LANDOWNER AT LOCATION OF UST INCIDENT
Landowner: A&M Family Farms, Inc. Address: 543 Johnson Farm Road
City: Lillington State: NC Zip Code: 27546 Telephone Number
Draw Sketch of Area (showing two major road intersections) or Attach Map
Person Reporting Incident Tom Will Company East Coast Environmental, PA Telephone Number 919-772-0268
Title Geologist Address 3815 Junction Boulevard, Raleigh, NC 27603 Date 10-17-22
UST Form 61 (02/19) Page 2 of 2
Definitions of Sources Tank: means the tank that stores the product and is part of the underground storage tank system Piping: means the piping and connectors running from the tank or submersible turbine pump to the dispenser or other end-use equipment (Vent, vapor recovery, or fill lines are excluded.) Dispenser: includes the dispenser and the equipment used to connect the dispenser to the piping (e.g., a release from a suction pump or from components located above the shear valve) Submersible Turbine Pump (STP) Area includes the submersible turbine pump head (typically located in the tank sump), the line leak detector, and the piping that connects the submersible turbine pump to the tank Delivery Problem: identifies releases that occurred during product delivery to the tank. (Typical causes associated with this source are spills and overfills.)
Other: serves as the option to use when the release source is known but does not fit into one of the preceding categories (e.g., for releases from vent lines, vapor recovery lines, and fill lines) Unknown: identifies releases for which the source has not been determined Definitions of Causes
Spill: use this cause when a spill occurs (e.g., when the delivery hose is disconnected from the tank fill pipe or when the nozzle is removed from the dispenser) Overfill: use when an overfill occurs (e.g., overfills may occur from the fill pipe at the tank or when the nozzle fails to shut off at the dispenser) Physical or Mechanical Damage: use for all types of physical or mechanical damage, except corrosion (e.g., puncture of tank or piping, loose fittings, broken components, and components that have changed dimension) Corrosion: use when a metal tank, piping, or other component has a release due to corrosion (e.g., for steel, corrosion takes the form of rust) Installation Problem: use when the problem is determined to have occurred specifically because the UST system was not installed properly Other: use this option when the cause is known but does not fit into one of the preceding categories (e.g., putting regulated substances into monitoring wells) Unknown: use when the cause has not been determined
910-893-9693
910-893-6963
East Coast
Environmental, P.A.
3815 Junction Boulevard
Raleigh, North Carolina 27603
(919) 349-5969
Figure 1
Site Location Map
A&M Farms
543 Johnson Farm Road
Lillington, Harnett County, NC
Scale:Prep. By:Rev. By:Date:
NTS TRW TRW 10/10/2022
N
Site Location
Source: USGS Lillington NC Quandrangle 2022
East Coast
Environmental, P.A.
3815 Junction Boulevard
Raleigh, North Carolina 27603
(919) 349-5969
Figure 2
Former UST Locations
A&M Farms
543 Johnson Farm Road
Lillington, Harnett County, NC
Scale:Prep. By:Rev. By:Date:
NTS TRW TRW 10/10/2022
N
Approximate Representation of Figure 3
Source: Google Earth
Former UST Locations
East Coast
Environmental, P.A.
3815 Junction Boulevard
Raleigh, North Carolina 27603
(919) 349-5969
Figure 3
Site Map With Petroleum
Contaminated Soil Excavation
A&M Farms
543 Johnson Farm Road
Lillington, Harnett County, NC
Scale:Prep. By:Rev. By:Date:
1” = 5'TRW TRW 10/10/2022
N
P-1 South
P-2 S-2 4'
T-1 P-1 6'
P-1 8'
P-1 South B
T-1 S-5 11'
P-1 North
T-1 P-1 2'
P-1 6'
P-1 7'
P-1 S-1 9'
T-1 East Sidewall
P-1 East
T-1 S-1 7'
T-1 S-2 10'
T-1 S-3 8'
T-1 S-4 10'
- Indicates Soil Sample Result Above
GRO/DRO Action Levels
Approximate Extent of Petroleum
Contaminated Soil Excavation
10' x 8' x 11' deep
Barn
Former 550 Gallon
Gasoline UST (T-1) and
Product Dispenser
Locations
- Indicates Soil Sample Result Below
GRO/DRO Action Levels
T-2 S-2
P-2 S-1 2'
Former 550 Gallon Diesel
UST (T-2) and Product Dispenser
Locations
T-1 South Sidewall
T-1 North Sidewall
T-1 West Sidewall
T-2 S-1
Approximate Location of
Temporary Well Installed
by S&EC during June 2022
East Coast
Environmental, P.A.
3815 Junction Boulevard
Raleigh, North Carolina 27603
(919) 349-5969
Figure 4
Receptor Information
A&M Farms
543 Johnson Farm Road
Lillington, Harnett County, NC
Scale:Prep. By:Rev. By:Date:
NTS TRW TRW 10/10/2022
N
5 0 0 -f o o t R a d i u s
1,000-foot Radius
On-Site
Well
L a n d S u r f a c e S lo p e