HomeMy WebLinkAboutNCS01662_INSP_20230202FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section
Page 1 of 2
UNIT TYPE:
Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Guilford
Closed MSWLF HHW White goods Incin T&P FIRM X PERMIT NO.: NCS-01662
CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE
Date of Site Inspection: 02/02/2023 Date of Last Inspection:
FACILITY NAME AND ADDRESS: M & P Septic & Grading, LLC 6268 Abernathy Road
Whitsett, NC 27377
GPS COORDINATES: N: NA E: NA
FACILITY CONTACT INFORMATION: Name: Matthew Lee Profitt Address: Same as above Telephone: 336-382-7207 Email address: mattprofitt@yahoo.com
PARTICIPANTS: Chester Cobb (DWM) STATUS OF PERMIT: Pending EXPIRES:
PURPOSE OF SITE VISIT: Pre-operational STATUS OF PAST NOTED VIOLATIONS:
NA
OBSERVED VIOLATIONS:
NONE
The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules.
FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section
Page 2 of 2
ADDITIONAL COMMENTS
1) Pumper vehicle(s) inspected:
TRUCK LICENSE PLATE # VIN # TANK CAPACITY (gal)
YA168831 1FV6GJBC5YHB87453 1,500
2) The required information of Firm name, town name, phone #, and permit # was on both sides of the
pumper vehicle. Each letter of the required information was three (3) inches or greater in height. The
lettering was distinguishable and not blocked from view. The lettering meets the requirements of 15A
NCAC 13B .0835(b). See pictures below.
3) The tank is made of steel and affixed to the frame of the truck as per 15A NCAC 13B .0835(a)(1). Talked
to Matt on 02/03/2023 about the bolts affixing the tank to the frame near the cab on both sides were
loose. Matt said that he was going to replace the bolts.
4) The valves appeared to be in working order and closed as per 15A NCAC 13B .0835(a)(2). Caps present
on ports.
5) Access ports were closed and properly sealed as per 15A NCAC 13B .0835(a)(3).
6) No leaks noticed as per 15A NCAC 13B .0835(a).
7) Truck in compliance with the Septage Rules.
8) Permit issued on 02/03/2023.
Driver side of pumper vehicle. Passenger side of pumper vehicle.
Please contact me if you have any questions or concerns regarding this inspection report.
____________________________________________ Phone: (919) 707-8283 . Chester R. Cobb, Environmental Program Consultant
Division of Waste Management, NCDEQ Regional Representative
Sent on: X Email Hand delivery US Mail Certified No. [ _]