HomeMy WebLinkAboutNCS01658_INSP_20230123FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 2 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Orange Closed MSWLF HHW White goods Incin T&P FIRM X PERMIT NO.: NCS-01658 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE Date of Site Inspection: 01/23/2023 Date of Last Inspection: FACILITY NAME AND ADDRESS: Mr. Ryan Jackson WasteAway Site Services LLC 960 Corporate Drive Suite 310 Hillsborough, NC 27278 GPS COORDINATES: N: NA E: NA FACILITY CONTACT INFORMATION: Name: Dan Brown Address: Same as above Telephone: 919-621-9111, Dan’s cell: 919-452-7231 Email address: ryan@wasteawaync.com; dan@wasteawaync.com PARTICIPANTS: Chester Cobb (DWM) and Dan Brown STATUS OF PERMIT: Pending EXPIRES: PURPOSE OF SITE VISIT: Pre-operational STATUS OF PAST NOTED VIOLATIONS: NA OBSERVED VIOLATIONS: NONE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 ADDITIONAL COMMENTS 1) Pumper vehicle(s) inspected: TRUCK LICENSE PLATE # VIN # TANK CAPACITY (gal) SR-7026 1FDUF5GT5NDA19572 900 waste / 300 fresh 2) The required information of Firm name, town name, phone #, and permit # was on both sides of the pumper vehicle. Each letter of the required information was three (3) inches or greater in height. The lettering was distinguishable and not blocked from view. The lettering meets the requirements of 15A NCAC 13B .0835(b). See pictures below. 3) The tank is made of aluminum and affixed to the frame of the truck as per 15A NCAC 13B .0835(a)(1). 4) The valves appeared to be in working order and closed as per 15A NCAC 13B .0835(a)(2). Caps present on ports. 5) Access ports were closed and properly sealed as per 15A NCAC 13B .0835(a)(3). 6) No leaks noticed as per 15A NCAC 13B .0835(a). 7) Truck in compliance with the Septage Rules. 8) Permit issued on 01/24/2023. Driver side of pumper vehicle. Passenger side of pumper vehicle. Please contact me if you have any questions or concerns regarding this inspection report. ____________________________________________ Phone: (919) 707-8283 . Chester R. Cobb, Environmental Program Consultant Division of Waste Management, NCDEQ Regional Representative Sent on: X Email Hand delivery US Mail Certified No. [ _]