Loading...
HomeMy WebLinkAbout0601_AveryCounty_MSWLF_Sept22LFG_FID1768199_20230123DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 DENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Smith Gardner, Inc. Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Joan A. Smvth. PG E-mail: joan@smithgardnerinc.com Phone: 919-828-0577 x 221 NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Avery County Closed MSW Landfill Brushy Creek Road, Spruce Pine, NC 06-01 .0500 September 22, 2022 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑ Detection Monitoring ❑X Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data El water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Joan A. Smyth, PG Senior Hydrogeologist 919-828-0577 x 221 e' tative Name (Print) Title (Area Code) Telephone Number -� 10/10/2022 Affix NC Licensed/ Professional Geologist Seal Date 14 N. Boylan Ave, Raleigh, NC 27603 Facility Representative Address F1370 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 � ARO 11 SEAI10/112 22 1369 .rO�FOLOG� M A. DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 This page intentionally left blank. DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 SMITH GARDNER ADDRESS TEL WEB 14 N. Boylan Avenue, Raleigh NC 27603 919.828.0577 www.smithgardnerinc.com October 10, 2022 Ms. Jaclynne Drummond NCDENR DWM Solid Waste Section 2090 U.S. 70 Highway Swannanoa, North Carolina 28778-8211 RE: Operations, Monitoring, and Maintenance Report — September 2022 Avery County Closed MSW Landfill(Permit No. 06-01) Spruce Pine, North Carolina Dear Ms. Drummond: On behalf of Avery County (County), Smith Gardner, Inc. (S+G) is pleased to present this report regarding the operation and maintenance (0&M) of the Avery County Closed MSW Landfill (Permit No. 06-011 Landfill Gas Collection and Control System (LFGCCS), and the perimeter monitoring probes for September 2022. Site details are provided below. SITE HISTORY The Avery County Closed MSW landfill is located approximately 0.6 miles southeast of the intersection of Highway 19 and Brushy Creek Mountain Road next to the Avery County Airport and the Unimin Corporation mine facility. There is no active mining in the immediate vicinity of the landfill. The MSW landfill was operated from 1970 until it closed in 1993. The property consists of approximately 14.4 acres, with the landfill footprint occupying approximately 9.6 acres of the site. Landfill topography ranges in elevation from approximately 2770 ft. msl to 2670 ft. msl, and slopes downhill toward Brushy Creek. Landfill gas monitoring and LFGCCS maintenance is completed on a monthly basis due to landfill gas concentrations detected in monitoring probes off -site. LFG COLLECTION AND CONTROL SYSTEM MONITORING ACTIVITIES The site has an active Landfill Gas Collection and Control System (LFGCCS) consisting of 10 landfill gas extraction wells (W-1 through W-10), HDPE piping for transmission of collected landfill gas, a one (1) horsepower blower, a condensate trap and storage tank, a candlestick flare, and associated valves and gauges. Well field and flare station data are provided in the attached Table 1. DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 Ms. Drummond October 10, 2022 Page 2 of 4 LFG Extraction Well Field • W-1 through W-10: S+G performed methane (CH4), oxygen (02), and carbon dioxide (CO2) monitoring as well as temperature and pressure monitoring. In general, gas quality varies across the wellfield. All wells with the exception of W-7 had recorded oxygen levels below 5% this sampling event. The wells will continue to be tuned to limit the concentration of oxygen in the landfill gas. Flare Station Gas quality measured at the flare is nominal with low levels recorded of methane, and moderate levels recorded of oxygen. The wellfield will continue to be monitored, tuned, and maintained as necessary to identify potential issues with the system and to improve gas quality levels. LFG MONITORING WELL (PERIMETER) MONITORING PROGRAM S+G performed monitoring of the perimeter LFG monitoring network during this event. The network consists of probes P-1 through P-13 located around the facility, and in some cases, on adjacent properties. Monitoring results for this month indicate the following probes have detectable methane concentrations: • P-1 • P-3 • P-7 Monitoring probes P-1, P-3, and P-7 all had observed concentrations above the lower explosive limit (LEL); the concentration in P-1 was 14.9%, P-3 was 1.4%, and P-7 was 20%. P-2 has not had a detectable level of methane in over a year. This has been noted and we will continue to closely monitor P-2 for any detectable methane levels in the future. Overall, the three (3) probes with detectable levels of methane saw a decrease in concentration from the August 2022 monitoring event. Attachment 1 includes the monitoring forms with results while Attachment 2 provides a CH4 concentration graph over time for monitoring wells that have historically had methane present. Monitoring of the current well network will continue, and data will be reported to NCDEQ and the County. CONCLUSIONS In general, the landfill gas extraction system continues to operate nominally. The landfill gas extraction wells will continue to be tuned to limit oxygen into the system. Monitoring probes P-1, P-3 and P-7 will continue to be monitored closely. S+G will continue to monitor the methane concentrations at the site monthly, and advise the County as needed on repairs required to maintain an effective collection system. DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 Ms. Drummond October 10, 2022 Page 3 of 4 The next monitoring event is scheduled for October 2022. If you have any questions, or require additional information, please contact us at your earliest convenience at 919-828-0577 or by e-mail (address below). Sincerely, SMITH GARDNER, INC. If DocuSigned by: �ut j U A Vu '0'1e.o SDD73DOAEAB2442... Daniel J. Pantaleo Environmental Technician ext. 140 daniel(asmithaardnerinc.com Attachments cc: Eric Foster - Avery County file CARO 4' ENS � O � IqEA, l 7 3Ci10/1 /2 DocuSigned by: B9779EA711F488... Joan A. Smyth, P.G. � B� Senior Hydrogeologist ext. 221 ioanfdsmithaardnerinc.com H:\Projects\Avery County INCI\02 AC Compliance\LFG Monitoring\MSW\2022\02 February 2022\February 2022 Avery MSW LFG Monitoring Report.docx 2 DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 Ms. Drummond October 10, 2022 Page 4 of 4 This page intentionally left blank. DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 11011,19 DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 This page intentionally left blank. DocuSign Envelope ID: CF521FFD-243D-42B6-9618-74CDA99759C8 a. ti 41 � ' ■i +9476 J 1. ;* + .. • Lot mm - `• ♦ i ► ' ION 1• . y• + r CIE ! �* w r \O.� AR- `gyp401 01 1 4' i •.' • M '�• t do y ,� *fit•' � 6 �,. -7,/ ,,�J � r� •,w �• � 1 I w .►�►•.� - It. Ir I • . r m . -op w jim;6it—u Rita 1111 0 P. 1. ;&1 v� 4�... • "` - AVERY COUNTY .!" �► #. V LANDFILL - ..we.. ' ` f . 40 �. r a �r 1 iiss1- � . ,,�, �! •� A LEGEND • T�� ' 1 • . 0 EXISTING LANDFILL GAS PROBE • +• ® OFFSITE STRUCTURE TO BE ' •^ ■ MONITORED ,,. •�;�` REFERENCES «�A 1. ADJACENT PROPERTIES ARE FROM AVERY COUNTY GIS MAPPING DEPARTMENT. _• r 2. MONITORING WELL LOCATIONS FROM FIELD SURVEY DATED 1/14/08, BY SURVEYING SOLUTIONS, P.C. 3. PROPERTY LINE FROM FIELD SURVEY DATED APRIL 9, 2010, BY .1�►.,N APPALACHIAN PROFESSIONAL LAND SURVEYORS & CONSULTANTS. • 4. LFG PROBES LOCATIONS FROM FIELD SURVEY DATED APRIL 9, 2010, BY APPALACHIAN PROFESSIONAL LAND SURVEYORS & CONSULTANTS. �, • • PROBE P-2, P-3, AND P-9 THROUGH P-13 LOCATIONS WERE NOT •; SURVEYED AND ARE APPROXIMATE. or•�411F 00 0 N 0 m w w z z a w � J O U-) a Z 1u U > C U Q G w Qa � Z J cn o W � d C/7 C j U Q : y x cm y o J V J a c � z ' z G U W c.3 x x W d Q v7 DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 This page intentionally left blank. DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 TABLES DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 This page intentionally left blank. DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 SMITH GARNER • 3.is O• • . •% • `�? • • • DQIE October 10, 2022 IX DJ P IhAoeID [ate 04 02 CY Etla-w Irit.TerWatLre Irit.gatic Resare P4.2atic Resare Irit.Dff. Resare* Irit.Rav N.R �em Resare m-d dcV yyyy % % % % deg F i n FPo i n I-0 i n I PO 3fm 3fm i n I PO AVERY-W1 9/22/2022 69.5 26.2 0.9 3.4 61.1 -2.18 -2.61 «« N/A N/A -1.95 AVE RY-W2 9/22/2022 43 23.1 1.9 32 66.4 -33.6 -34.37 -0.836 0 0 -35.57 AVERY-W3 9/22/2022 66.6 33.4 0 0 69.7 1.28 1.71 0.021 0.5 0.6 -36.06 AVE RY-W4 9/22/2022 27.1 18.3 3.1 51.5 75•4 -35.71 -35.89 -0.208 «» «» -35.56 AVERY- W5 9/22/2022 23.4 21.4 2.5 52.7 75.5 - 35.18 - 35.13 -1.072 0 0 - 35.89 AVERY- W6 9/22/2022 11.8 17.4 4.6 66.2 75 -11.66 -11.76 - 0.103 «» «» - 36.09 AVERY-W7 9/22/2022 1.6 7.5 12.8 78.1 81.9 -29.22 -24.79 -3.379 0 0 -36.24 AVERY-W8 9/22/2022 47.6 33.5 1.9 17 79•5 -36.32 -36.33 -0.154 «» «» -36.28 AVERY- W9 9/22/2022 36.5 24.8 1.6 37.1 68.1 - 36.1 - 36.22 - 0.224 «» «» - 36.33 AVERY-W10 9/22/2022 61.5 25.5 1.9 11.1 67.7 -34.99 -35.29 -0.489 «» «» -35.68 Av-Flare 9/22/2022 1 16.5 1 12 1 9.6 1 61.9 1 78.1 1.61 1 1.65 1 1.255 1 25.3 1 22.9 - 0.02 i - I I I I I I I I I I -J *The differential pressure measurement should be positive. A negative differential pressure may indicate no gas flow. Negative differential pressure can be the result of dirt or water obstructing the pitot tube perforations. Oderpulling by adjacent extraction wells may also result in negative pressure being displayed. NR= not recorded DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 This page intentionally left blank. DocuSign Envelope ID: CF521FFD-243D-42B6-9618-74CDA99759C8 ATTACH MEN T1 PERIMETER MONITORING PROBE DATA DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 This page intentionally left blank. DocuSign Envelope ID: CF521FFD-243D-42B6-9618-74CDA99759C8 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Avery County Closed MSW Landfill Permit Number: 06-01 Date of Sampling: 09/22/2022 NC Landfill Rule (.0500 or .1600): .0500 Name and Position of Samnle Collector- Daniel J. Pantaleo Staff Environmental Technician Type and Serial Number of Gas Meter: GEM5000, G506472 Date and Time of Field Calibration: 09/22/2022, 0900 Calibration Date of Gas Meter: 12/2021 Type of Field Calibration Gas (15115 or 35/50): 35/15 Expiration Date of Field Calibration Gas Canister: 10/2023 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 73 F Barometric Pressure: 29.95 in Hg General Weather Conditions: Cloudy Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 Location or LFG Well ID Sainple Tube Purge Time Time Pumped (s) Initial °,ZEL Stabilized °,,ZEL Of4CH4 by Volume %02 %CO2 Notes H 2 S p p m P-1 >60s 1109 >60s 282 282 14.1 13.2 8.2 4 P-2 >60s 1044 >60s 0 0 0.0 19.7 0.0 1 P-3 >60s 1040 >60s 52 52 2.6 15.9 4.2 4 P-4 >60s 1031 >60s 0 0 0.0 19.7 0.0 2 P-5 >60s 1027 >60s 0 0 0.0 17.6 3.1 3 P-6 >60s 1022 >60s 0 0 0.0 18.7 1.0 3 P-7 >60s 1017 >60s 174 174 8.7 0.7 16.7 5 P-8 >60s 1010 >60s 0 0 0.0 17.4 2.8 3 P-9 >60s 1052 >60s 0 0 0.0 18.3 1.7 4 P-10 >60s 1048 >60s 0 0 0.0 14.1 6.6 3 P-11 >60s 1036 >60s 0 0 0.0 15.7 3.7 3 P-12 >60s 1014 >60s 0 0 0.0 18.7 3.0 7 P-13 >60s 1100 >60s 0 0 0.0 13.5 6.9 2 Airport Structures >60s 1104 >60s 0 0 0.0 19.6 0.0 3 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. DocuSigned, by: by LkVUJ U O V(;i kj¢A SIGNATURE Staff Environmental Technician TITLE DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 This page intentionally left blank. DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 ATTACHMENT 2 HISTORICAL PERIMETER MONITORING PROBE TRENDS DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 This page intentionally left blank. DocuSign Envelope ID: CF521 FFD-243D-42B6-9618-74CDA99759C8 SMITH GARDNER % CH4 by Volume 80.0 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0.0 0 AA MY, F. Mo fl • • to N N cn 1 N cn By: DJP Date: 10/ 10/2022 N P1 Wei I P3 P7