HomeMy WebLinkAbout16017_Carolina Medical Electronics_SIR_20220929
DWM Brownfields Inspection Report
Submitted By: jkslaughter_ncdenr
Submitted Time: 09/30/2022 6:46 AM
I. Inspection Information
Date & Time: 09/28/2022 9:09 AM Inspection Type: Meeting
Brownfields Staff:
Kevin Slaughter, Seth Titley, Tyler Pearson
Other Personnel:
Leonard Speaks, Doug Boelsche, Joe Landry
Location:
Lat: 36.26717105, Long: -80.37341889
Brownfields Inspection Report: Carolina Medical Electronics, 16017-12-085
09/28/2022 9:09 AM
Page 2 of 7
II. Project Information
Number: 16017-12-085 Name: Carolina Medical Electronics
Address: 157 Industrial Drive
City: King
County: Stokes
III. Environmental
Current Use of Property: Industrial
Structures on Property: Existing and New Construction Structures Violation: No
Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No
Use of Surface Water or Groundwater: Not Observed Water Use Violation: No
Exposed Soils: Observed Exposed Soils Violation: No
Summary: A passive VIMS is being installed within the corrugated steel building currently
under construction (Photos 1 & 2) and there is a positive pressure VIMS installed within
the existing masonry building. The interior of the existing building is pressurized relative
to the sub-slab to prevent vapor intrusion into the building (Photo 3).
Summary: N/A
Summary: There is an existing 1-story masonry building currently in use as a machine
shop, with a new corrugated steel building under construction to the northwest. The
erosion control measures, stormwater detention pond, and the recent overflow of
stormwater over Industrial Ext Dr are related to construction on the property.
Summary: Recent grading has occurred around the perimeter of the building currently
under construction and within the associated stormwater control system (Photos 4 & 5).
In addition, the City of King was installing a sewer line extension along the southwestern
border of the property during the Site Inspection (Photos 6 &7).
Brownfields Inspection Report: Carolina Medical Electronics, 16017-12-085
09/28/2022 9:09 AM
Page 3 of 7
Use of Basements: Not Observed Basement Violation: No
Storage of Chemicals: Observed Chemical Violation: No
Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No
Current Exposure to Public/Public Risk:
Summary: N/A
Summary: Hydraulic oil and small quantities of lubricants were observed within the
machine shop. There were no signs of spillage observed, or quantities more than what’s
permissible under the LUR’s for the property.
Condition:
Summary: N/A
No environmental risk of exposure was observed at the time of the site inspection.
However, the perimeter of the property is not fenced, and the steep rip-rap banks and
detention pond (Photos 4 & 5), and the City of King utility work (Photo 6) could present
potential physical risks to trespassers.
Brownfields Inspection Report: Carolina Medical Electronics, 16017-12-085
09/28/2022 9:09 AM
Page 4 of 7
IV. Inspector Comments
V. PHOTOGRAPHS
Photo 1: Photo taken within new building currently under construction. PVC VIMS risers visible
adjacent to steel support columns.
The Site Inspection was performed as a result of stormwater run-off on the northern end
of the property which crossed over the adjacent gravel road (Industrial Ext Dr.). On
arrival, very little evidence of the overflow was visible (Photo 4), and the stormwater
management system had been completed (significant amount of riprap for bank
stabilization was added as seen in Photos 4 & 5). While on-site, the VIMS within the new
and existing buildings were also inspected (Photos 1-3). No issues were identified with
the VIMS, although a thin layer of floor epoxy will need to be chipped away to access the
sub-slab monitoring points within the new building.
Brownfields Inspection Report: Carolina Medical Electronics, 16017-12-085
09/28/2022 9:09 AM
Page 5 of 7
Photo 2: Typical VIMS siphon vent installed on rooftop of building under construction.
Photo 3: One of two digital pressure gauges within the existing building (157 Industrial Dr.)
showing indoor positive pressure (pascals) relative to sub-slab pressure.
Brownfields Inspection Report: Carolina Medical Electronics, 16017-12-085
09/28/2022 9:09 AM
Page 6 of 7
Photo 4: View facing northwest from property. Slight discoloration visible on Industrial Ext Dr.
from stormwater overflow that took place prior to the completion of the detention basin.
Photo 5: View facing north from property. Completed stormwater detention pond visible in
photograph.
Brownfields Inspection Report: Carolina Medical Electronics, 16017-12-085
09/28/2022 9:09 AM
Page 7 of 7
Photo 6: City sewer line extension taking place along western property boundary during the
Site Inspection. Excavated soil is placed back in trench upon completion (Photo 7).
Photo 7: Section of completed sewer line trench following compaction, grading, and seeding.