HomeMy WebLinkAboutSDTF0204_INSP_20220928NORTH CARnLINAD_E Q�� o.n.mm.m m c.w.mm.m.i a.i� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined LCID YW Transfer Compost SLAS COUNTY: Alexander MSWLF PERMIT NO.: SDTF-02-04 Closed HHW White Incin T&P FIRM MSWLF goods FILE TYPE: COMPLIANCE CDLF Tire T&P/ Tire Industrial DEMO SDTF X Collection Monofill Landfill Date of Site Inspection: 09/28/2022 FACILITY NAME AND ADDRESS: Taylorsville Precast Molds, Inc. Henry Road Taylorsville, North Carolina 28681 Date of Last Inspection: 10/21/2021 GPS COORDINATES: N: 35.88249 W: 81.13232 FACILITY CONTACT INFORMATION: Name: David Mecimore Telephone: (828) 632-4608 Email address: tpm@twave.net PARTICIPANTS: Stephanie Williams, DWMSolid Waste Section Chester Cobb, DWMSolid Waste Section STATUS OF PERMIT: Active EXPIRES: 0212512024 PURPOSE OF SITE VISIT: Routine Inspection STATUS OF PAST NOTED VIOLATIONS: The leak noted in the 10/21/2021 inspection report has been repaired and the repair remains in tact. OBSERVED VIOLATIONS: N/A The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. Page 1 of 2 FACILITY COMPLIANCE INSPECTION REPORT D_E Q�� Division of Waste Management NORTH CAROLINA Ow-- W Emironm l puelily Solid Waste Section ADDITIONAL COMMENTS 1) This facility consists of one 1,500 gallon concrete tank and one 3,500 gallon concrete tank for storage and treatment of domestic septage, portable toilet waste, and grease trap pumpings. 2) Setback requirements appear to have been met. At the time of inspection, vegetation was present within 5-feet of the tanks, not meeting the requirement of Rule 15A NCAC 13B .0838(i). Following the inspection, Mr. Mecimore had the vegetation cleared surrounding the tanks. 3) Appropriate signate was observed at the entrance to the site. 4) The access road was adequately maintained to meet the requirements of Rule 15A NCAC 13B .0838(b). 5) No holes or cracks which may allow the escape of septage out of the tanks were observed. The tanks appeared to be in compliance with Rule 15A NCAC 13B .0838(c). As noted on the previous page, the repair of a leak previously noted appears to be in tact. 6) Septage appears to be transferred to and from the tanks in a manner that prevents leaks or spills of septage onto the tank or ground as per 15A NCAC 13B .0838(j). 7) No vector or odor issues were noticed as covered within Rules 15A NCAC 13B .0838(e)(2) and .0838(g). Please contact me if you have any questions or concerns regarding this inspection report. ,tyw� Phone: (919) 605-5576 St p ah nie Williams, Environmental Specialist Division of Waste Management, NCDEQ Regional Representative Sent on: ll/16/2022 X Email Hand delivery US Mail Certified No. r I Page 2 of 2