HomeMy WebLinkAbout6301_MooreCounty_MSWLF_CDLF_Dec2022LFG_FID1756001_20221220%ENR USE ONLY: ❑Pa er Report ❑Electronic Data - Email CD data loaded: Yes / No Doc/Event #:
C DENR I IEnvironmental Monitoring
Division of Waste Management - Solid Waste Reporting Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
• Prepare one form for each individually monitored unit.
• Please type or print legibly.
Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification
must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing
condition, etc.).
• Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits.
• Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the
facility (NCAC 13B .1629 (4)(a)(i).
Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste
Section, 1646 Mail Service Center, Raleigh, NC 27699-1646.
Solid Waste Monitoring Data Submittal Information
Name of entity submitting data (laboratory, consultant, facility owner):
S&ME, Inc. (on behalf of Moore County)
Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address:
Name: Edmund Q.B. Henriques Phone: 336-288-7180
E-mail: ehenriques@smeinc.com
NC Landfill Rule: Actual sampling dates (e.g.,
Facility name: Facility Address: Facility Permit # (.0500 or. 1600) October 20-24, 2006)
December 16, 2022
Moore County Landfill 456 Turning Leaf Way, Aberdeen, NC 63-01 .0500
Environmental Status: (Check all that apply)
Initial/Background Monitoring Q Detection Monitoring Assessment Monitoring Corrective Action
e of data submitted: (Check all that apply)
Groundwater monitoring data from monitoring wells xQ
Groundwater monitoring data from private water supply wells El
Leachate monitoring data ❑
Surface water monitoring data x
Methane gas monitoring data
Corrective action data (specify)
Other(specify) Pilot Test Well Methane Data
Notification attached?
B No. No groundwater or surface water standards were exceeded.
Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water
monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and
preliminary analysis of the cause and significance of any concentration.
�ir Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample
values and explosive methane gas limits.
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct.
Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas
levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
Edmund Q.B. Henriques, PG Senior Geologist, S&ME Inc. 336-312-3330
Facility Representative Name (Print) Title (Area Code) Telephone Number
N•w•h•p
(�71 a o /-)- n ; � 12/19/2022 Affix NC Lic PtoitAbGeoloaist Seal
Signature i \ // Date
8646 W. Market Street, Suite 105, Greensboro NC 27409
Facility Representative Address
F-0176
NC PE Firm License Number (if applicable effective May 1, 2009)
Revised 6/2009
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Moore County Landfill Permit Number: 63-01
Sampling Date: December 16, 2022 NC Landfill Rule (.0500 or.1600): 0.0500
Sample Collector Name & Position: Ed Henriques / Senior Geologist, S&ME, Inc.
Gas Meter Type & Serial Number: GEM 5000 / SN G504951
Field Calibration Date & Time: 12/14/2022
Gas Meter Calibration Date: 3/22/2022
Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 01 /2025
Gas Meter Pump Rate: 720 cc/min
Ambient Air Temperature: 50 F Barometric Pressure (in. or mm Hg): 29.45 Weather Conditions: Sun
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See
individual permit conditions and/or Facility LFG monitoring plan.
Location or
LFG Well ID
S ample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
% LEL
Stabilized
% LEL
% CH4
� volume �
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
GP-9
60
1 008
120
0
0
0.0
20.3
1.2
0
Property Boundary Monitoring Point
G P 10 R
60
1021
120
0
0
0.0
18.9
2.5
0
Property Boundary Monitoring Point
1
GP-1 1
60
1029
120
0
0
0.0
16.6
2.2
0
Property Boundary Monitoring Point
G P-12
60
1 059
120
0
0
0.0
20.9
1.1
0
Property Boundary Monitoring Point
GP-1 3R
60
1135
120
0
0
0.0
20.7
0.8
0
Property Boundary Monitoring Point
G P-14 R
60
1143
120
0
0
0.0
12.9
2.9
0
Property Boundary Monitoring Point
GP-1 5R
60
1156
120
0
0
0.0
20.6
0.9
0
Property Boundary Monitoring Point
G P-16
60
1120
120
0
0
0.0
7.1
14.7
0
Property Boundary Monitoring Point
GP-1 7
60
1111
180
58
58
2.9
0.2
16.1
0
Property Boundary Monitoring Point
G P-18
60
1239
180
> 100
> 100
56.5
0.1
38.5
0
Property Boundary Monitoring Point
G P-19
60
1218
120
0
0
0.0
17.4
4.9
0
Property Boundary Monitoring Point
NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility.
ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or certification including the possibility of a fine and imprisonment.
Senior Geologist / S&ME, Inc.
SIGNATURE TITLE
Revised - March 6, 2017
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Moore County Landfill Permit Number: 63-01
Sampling Date: December 16, 2022 NC Landfill Rule (.0500 or. 1600): 0.0500
Sample Collector Name & Position: Ed Henriques / Senior Geologist, S&ME, Inc.
Gas Meter Type & Serial Number: GEM 5000 / SN G504951
Field Calibration Date & Time: 12/14/2022
Gas Meter Calibration Date: 3/22/2022
Field Calibration Gas Type (15/15 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 10/2027
Gas Meter Pump Rate: 720 cc/min
Ambient Air Temperature: 50 F Barometric Pressure (in. or mm Hg): 29.45 Weather Conditions: Sun
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See
individual permit conditions and/or Facility LFG monitoring plan.
Location or
LFG Well ID
S ample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
initial
/o LEL
Stabilized
/o LEL
% CH4
(volume)
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
MW-6
60
1209
180
>100
>100
13.8
4.8
15.9
0
not a compliance point
GV-33
60
1245
180
> 100
>100
54.2
0.2
38.8
< 1
Passive vent, not a compliance point
GV-34
60
1251
180
>100
>100
47.6
0.1
38.0
0
Passive vent, not a compliance point
GV-35
60
1300
180
>100
>100
56.4
0.2
40.0
0
Passive vent, not a compliance point
GV-36
60
1307
180
>100
>100
57.0
0.1
40.0
0
Passive vent, not a compliance point
Maintenance Shop
60
1048
120
0
0
0.0
21.1
0.1
0
on -site structure
Transfer Station
60
1039
120
0
0
0.0
21.1
0.1
0
on -site structure
Blake Residence
60
1342
120
0
0
0.0
21.4
0.0
0
off -site structure
Scale House
60
1002
120
0
0
0.0
21.1
0.1
0
on -site structure
GP-20
60
1227
180
>100
>100
27.4
0.1
26.1
0
Monitoring point, west of cut-off trench
GP-21
60
1320
180
>100
>100
51.4
1.8
36.6
0
Monitoring point, east of cut-off trench
NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility.
ACTION LEVELS: Methane: >_1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or certification including the p ssibility of a fine and imprisonment.
Senior Geologist / S&ME, Inc.
SIGNATURE TITLE
Revised - March 6, 2017
Table 1
Summary of 2020 & 2022 Methane Gas Readings
Moore County Landfill (Permit 63-01)
Moore County, North Carolina
S&ME Project No. 4358-20-043A
Location Scale- house
g Point Type •
7
02/17/20 0.0%
Maintena
Shop
•
0.0%
Station
•
0.0%
Blake
Crawlspace
•V,f,
0.0%
GP-9
0.0%
r
footn tel#
18.7%
WUFMl!
not installed
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
See
footnote#2
0.0%
0.0%
0.0%
0.0%
See
footnote#1
11.9%
Al
28.1%
not installed
r
See
footnote#4
not installed
NEGEMEM
See
footnote#4
not installed
04/07/20
0.0%
0.0%
0.0%
0.0%
0.0%
32.2%
not installed
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.4%
23.6%
59.9%
not installed
not installed
not installed
09/15/20
0.1%
0.0%
0.0%
0.0%
0.1%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
0.0%
22.5%
0.0%
not installed
not installed
12/14/20
0.0%
0.0%
0.0%
0.1%
0.1%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.5%
9.6%
61.3%
0.0%
not installed
not installed
02/24/21
0.0%
0.0%
0.0%
NM
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.4%
28.7%
67.9%
0.0%
not installed
not installed
04/12/21
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.2%
2.0%
21.8 %
0.0%
not installed
not installed
09/29/21
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.0%
19.5%
57.5%
0.0%
not installed
not installed
12/17/21
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
13.8%
27.8%
0.0%
10.1%
57.0%
03/25/22
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
29.1%
54.7%
0.0%
28.1%
56.4%
06/06/22
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
4.7%
42.4%
0.0%
30.5%
56.5%
09/26/22
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
1 0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.1%
9.5%
50.8%
0.0%
13.7%
56.1%
12/16/22
0.0%
0.0%
0.0%
1 0.0%
1 0.0%
1 abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
2.9%
13.8%
56.5%
0.0%
27.4%
51.4%
Notes:
Monitoring Point Types: PB = Property Boundary, ONSS = On Site Structure, OFFSS = Off -site Structure
Footnote#1 = MW-6 was replace by GP-19 as the property boundary compliance point. MW-6 is approximately 150 feet inside the property boundary and not a compliance point.
Footnote#2 = GP-10 was replaced by GP-10R, GP-13 replaced by GP-13R, GP-14 replaced by GP-14R, GP-15 replaced by GP-15R
Footnote#3 = Groundwater monitoring well MW-15 converted to gas monitoring point now identified as GP-18, which is a property boundary compliance point.
Footnote#4 = Gas monitoring points installed for a cancelled active gas extraction pilot test. A new passive venting pilot test has been proposed.
all measurements recorded in percent methane by volume
Lower explosive limit of methane gas: 5%
Upper explosive limit of methane gas: 15%
Data recorded prior to 9/15/20 obtained by Golder
not installed = Well not installed at the time of monitoring
Yellow highlight cells and values in bold print indicate methane percent by volume greater than or equal to 5% at property boundary monitoring point
Orange highlight cells and values in bold print indicate methane percent by volume greater than or equal to 1.25% inside structures.
TAENV\Projects\2020W5&20-A -- County Routine Los & WQMo-ring\Phase 06- Q -dy-h- Monitoring 2022-2023\- R-mg,-1I ,- Charts IN -RESfi 1. 12/19/2022
ENVIRO-EQUIPMENT, INC.
i
LANDTEC GEM 5000 Plus CALIBRATION
DATA SHEET
Serial N��,�um""""ber G SOLI �l S kDate
2 Inspector
Time/Date Battery Level 1 Rio Memory Cleared�
Pump Faults
Gas Alarms: CHq = 100.0% QQU CO,= 100.0%
_1
02 = 22.0% O� T
cc
Zero Transducers Pump Flow Rate TZ �mi
Vacuum Tested To 80" H2O CN2l4
{ T
Calibration Check (Performed at Roo
Temperature)
It
Calibration Gas Calibration Gas Lot Number Ex
Concentration
(]
Pure N2 =� rai• LW$a1585 01A
iration Reading Accuracy*
(z)2 100ago t 2%
High CH4 50lu y025381-125 10
2 S(Z, I to f 20/n
High CO2 3S°lo 4011533�+25
2:1 35.2P7o t 2%
Low CH, 1590
74 1 &- CD` f 2%
Low CO2 15 le t'i�2�1g rJ�ZS
7]e
2� I'JI . y� to f 2%
Low0z —f�e ItiZa��2 �2
�2� 'i, �o t2%
High 02 20.9% N/A
A 2 . 1 alo t 2%
CO
f 10%
H2s I ��p.v+ 1514�2� 12
23 fD ,.^ =10%
*Accuracy depends upon calibration range; 15%-FS range for CH, & COZ, 0-5% volume
L
ror Oz, 0%-FS for HzS, and 10%of reading for CO.
INSPECTOR'S MAINTENANCE
NOTES
Ear GEM 2000 Plus Cal Fonn 01112
No. 66916
Date Of Calibration: 22-Mar-2022
Customer: ENVIRO EQUIPMENT INC
11180 DOWNS RD PINEVILLE, NC 28134
Description: Landtec Gas Analyzer
Model: GEM5000
Serial Number: G504951
Accredited Results:
Methane CH4)
Certificate Number: G504951_9/43759
Certified Gas N
Instrument Reading %
Uncertain %
5.0
4.8
0.42
15.0
14.9
0.66
50.0
49.3
1.03
Carbon Dioxide CO21
Certified Gas (%__
Instrument Reading %
Uncertainty%
5.0
4.7
0.43
15.1
14.7
0.71
50.0
50.2
1.19
Oxygen 02
Certified Gas 4b
Instrument Reading %
EEL)ncertai nt /
20.8
20.9
n 5
_.__
Gas cylinders are traceable and details can be provided if
requested.
CH4, CO2 readings recorded at: 30.4 `C/86.7 °F Barometric Pressure: 0984"Hg/29.05 "Hg
02 readings recorded at: 21.5 °C/70.7 °F
Method of Test : The analyzer is calibrated in a temperature controlled chamber using a series of reference
gases, in compliance with procedure ISPi7.
The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2,
providing a level of confidence of approximately 95%. The uncertainty evaluation has been carried out in accordance
with NIST requirements.
The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System of
Units (SI). Certification only applies to result shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory.
Calibration I x=ce: 114 ItiC Innanec: 114 Page I or21 LPoISLNANIST-1.1
PJLA
fatiDrallan
No. 66916
Date Of Calibration: 22-Mar-2022
Non Accredited results:
Certificate Number: G504951 9/43759
Pressure Transducers finches of water column
Transducer Certified (Low) Reading (Low) Certified (High) Reading (High) Accuracy
Static
0"
0"
40"
40.07"
2.0"
Differential
0"
0"
4"
4.02"
0.7"
Barometer (mbar)
Reference instrument Reading
0984 mbar / 29.05 "Hg 0984 mbar / 29.06 "Hg
As received gas check readings:
Methane CH4
Certified Gas %
Instrument Reading%
5.0
5.0
15.0
14.8
50.0
49.5
Carbon Dioxide CO2
Certified Gas ro/1
Instrument Reading
5.0
5.2
15.1
15.0
50.0
48.2
Oxygen 02
Certified Gas %
Instrument Reading
i
20.8
20.9
As received Gas readings recorded at: 30.4 °C/86.7 -F
As received Barometric Pressure recorded at: 21.5 `C/70.7 T
Date of Issue : 23 Mar 2022 Approved By Signatory
Craig McPherson
fabonnory Inspection
The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through MIST to the International System of
Units (5I). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory.
Celib.,, Insuuce: 114 IGC Instmrc 114 Pegc2of2 I LKISLNA IST-1.1