HomeMy WebLinkAbout4101_Guilford_HighPoint_MSWLF_Seaboard_Dec22LFG_FID1755965_20221216DocuSign Envelope ID: B6DC37A5-2CE7-4839-8348-1 1 C68C5B38BE
DENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #:
NC DENR I I Environmental Monitoring
Division of Waste Management - Solid Waste Reporting Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
Prepare one form for each individually monitored unit.
Please type or print legibly.
Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification
must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing
condition, etc.).
Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits.
Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the
facility (NCAC 13B .1629 (4)(a)(i).
Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste
Section, 1646 Mail Service Center, Raleigh, NC 27699-1646.
Solid Waste Monitoring Data Submittal Information
Name of entity submitting data (laboratory, consultant, facility owner):
Smith Gardner, Inc.
Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address:
Name: Seth C. Rickerts, PG
E-mail: seth@smithgardnerinc.com
Phone: (919) 828 - 0577 x135
NC Landfill Rule: Actual sampling dates (e.g.,
Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006)
High Point Riverdale Closed MSW Riverdale Drive, High Point, NC 41-01 .0500 December 14, 2022
Landfill
Environmental Status: (Check all that apply)
❑ Initial/Background Monitoring ❑X Detection Monitoring ❑ Assessment Monitoring Corrective Action
of data submitted: (Check all that apply)
Groundwater monitoring data from monitoring wells ❑X
Groundwater monitoring data from private water supply wells ❑
Leachate monitoring data El
water monitoring data
Methane gas monitoring data
Corrective action data (specify)
Other(specify)
Notification attached?
e No. No groundwater or surface water standards were exceeded.
Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water
monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and
preliminary analysis of the cause and significance of any concentration.
❑X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample
values and explosive methane gas limits.
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct.
Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas
levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
Seth C. Rickerts, PG Project Geologist (919) 828 - 0577 x135
Facility Representative Name (Print)
Title
Yss^°"1,, 1L/l�/LVLL
a< c,. 2Z�"s
Signature B8305C9'BEA0E6 Date
14 N. Boylan Ave, Raleigh, NC 27603
Facility Representative Address
F-1370
NC PE Firm License Number (if applicable effective May 1, 2009)
Revised 6/2009
(Area Code) Telephone Number
Affix NC Licensed/ Professional Geologist Seal
GA
pQ'�f�E .40
SE L
12 15 27
__022
0,
"DI.OG��' 4`
DocuSign Envelope ID: B6DC37A5-2CE7-4839-8348-1 1 C68C5B38BE
This page intentionally left blank.
DocuSign Envelope ID: B6DC37A5-2CE7-4839-8348-11C68C51338BE
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and
examination by any person upon request (NC General Statute 132-6).
Facility Name: City of High Point Closed Riverdale Landfill Permit Number: 41-01
Date of Sampling: 12/14/2022 NC Landfill Rule (.0500 or .1600): .0500
Name and Position of Sample Collector: Kyle M. Bonnett - Staff Environmental Technician
Type and Serial Number of Gas Meter: GEM 5000, R8200045 Calibration Date of Gas Meter: 12/2021
Date and Time of Field Calibration: 12/14/2022, 1218
Type of Field Calibration Gas (15115 or 35/50): 35/50 Expiration Date of Field Calibration Gas Canister: N/A
Pump Rate of Gas Meter: 0.5 LPM
Ambient Air Temperature: 45 F Barometric Pressure: 29.33 in Hg General Weather Conditions: Cloudy
Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test
must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane
by volume = % LEL/20
Location or
LFG Well ID
Sample Tube
Purge
Time
Time
Pumped (s)
Initial
gZEL
Stabilized
°,,ZEL
df4CH4
by
Vohlme
%02
%CO2
Notes
H2 S ppm
1-1
>60s
1314
>60s
0
0
0.0
16.2
4.1
0
LFG 3
>60s
1309
>60s
0
0
0.0
20.1
1.9
0
LFG 4
>60s
1320
>60s
0
0
0.0
17.8
2.9
0
LFG 5
>60s
1323
>60s
0
0
0.0
14.1
5.0
0
LFG 6
>60s
1326
>60s
258
258
12.9
4.3
24.0
0
LFG 7
>60s
1348
>60s
1294
1294
64.7
0.2
29.4
2
7-1
>60s
1351
>60s
612
612
30.6
0.3
32.2
1
7-2
>60s
1347
>60s
0
0
0.0
20.2
1.6
0
7-3
>60s
1345
>60s
542
542
27.1
0.1
34.9
3
7-4
>60s
1343
>60s
1102
1102
55.1
0.1
33.3
1
LFG 8
>60s
1339
>60s
942
942
47.1
3.1
36.0
2
LFG 8A
>60s
1340
>60s
1358
1358
67.9
0.2
30.1
7
LFG 8B
>60s
1341
>60s
1170
1170
58.5
0.2
41.4
3
8-1
>60s
1336
>60s
1218
1218
60.9
0.2
31.2
0
8-2
>60s
1335
>60s
1114
1114
55.7
0.3
44.1
0
8-3
>60s
1333
>60s
1194
1194
59.7
0.4
39.8
0
8-4
>60s
1355
>60s
1048
1048
52.4
0.3
38.7
0
8-5
>60s
1358
>60s
212
212
10.6
6.7
21.8
1
LFG 9
>60s
1359
>60s
1056
1056
52.8
1.1
35.1
1
9-1
>60s
1401
>60s
896
896
44.8
0.2
38.3
1
LFG 10
>60s
1403
>60s
0
0
0.0
14.7
5.4
0
Old Maint Bldg
>60s
1327
>60s
0
0
0.0
20.6
0.0
0
Electrical Shop
>60s
1328
>60s
0
0
0.0
20.6
0.0
0
If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same
information as contained on this form.
Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that
there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
EDII"Sig"Id
y�"�''�by:
1 g #-A34ZED .
Staff Environmental Technician
SIGNATURE
TITLE
DocuSign Envelope ID: B6DC37A5-2CE7-4839-8348-1 1 C68C5B38BE
This page intentionally left blank.
DocuSign Envelope ID: B6DC37A5-2CE7-4839-8348-1 1 C68C5B38BE
Q
O
M
C)
M
O
N
X
E
C
0
I
L
LM
U
N
0
H
Z_
U
Z
C
O
d
L
U
O
a_
s■
;i 4-
*N
# 1.
Y. N
0.
LI,
Pr
Aba
i 's -
•
is
- 7•y4 � � 1�
�
''r _
•
#` F4VOP
• •l • •#• -cn
LL