Loading...
HomeMy WebLinkAbout23074 - Environmental Management Plan_Bookers Garage _FINAL_20210330hart '� hickman SMARTER ENVIRONMENTAL SOLUTIONS Via Email February 25, 2021 NCDEQ — Division of Waste Management Brownfields Program 1646 Mail Service Center Raleigh, NC 27699-1646 Attn: Ms. Kathleen Markey Re: Environmental Management Plan Bookers Garage Charlotte, North Carolina Brownfields Project No. 23074-19-060 H&H Project No. SCF-001 Dear Ms. Markey: On behalf of 1121 Seigle, LLC, please find the enclosed Environmental Management Plan prepared for the Bookers Garage Brownfields property for your review and approval. Should you have any questions or need additional information, please do not hesitate to contact me at (704) 586-0007. Sincerely, Hart & Hickman, PC Vv l Ralph McGee, PG Project Manager cc: Mr. Harrison Tucker, SpaceCraft (Via Email) Ms. Laura Truesdale, Alexander Ricks (Via Email) Ms. Jordan Thompson, DEQ Brownfields Program (Via Email) Enclosure: 2923 South Tryon Street, Suite 100 3921 Sunset Ridge Rd, Suite 301 Charlotte, NC 28203 Raleigh, NC 27607 www.harthickman.com 704.586.0007 main 919.847.4241 main Environmental Management Plan Bookers Garage 1113 - 1121 Seigle Avenue and 820 E. 15t" Street Charlotte, North Carolina Brownfields Project No. 23074-19-060 H&H Job No. SCF-001 February 25, 2021 hart hickman SMARTER ENVIRONMENTAL SOLUTIONS #C-1269 Engineering #C-245 Geology 2923 South Tryon Street, Suite 100 3921 Sunset Ridge Rd, Suite 301 Charlotte, NC 28203 Raleigh, NC 27607 www.harthickman.com 704.586.0007 main 919.847.4241 main Completed EMP Template Form CONTENTS Tables Table 1 Summary of Soil Analytical Data Table 3 Summary of Groundwater Analytical Data Table 4 Summary of Soil Gas Analytical Data Figures Figure 1 Site Location Map Figure 2 Sample Location Map Figure 3 Compound Concentration Map Appendices Appendix A Redevelopment Plan and Permits Appendix B Preliminary Construction Schedule Appendix C — Cut -Fill Analysis NORTH CAROLINA BROWNFIELDS PROGRAM ENVIRONMENTAL MANAGEMENT PLAN This form is to be used to prepare an Environmental Management Plan (EMP) for projects in the North Carolina Brownfields Program at the direction of a Brownfields project manager. The EMP is a typical requirement of a Brownfields Agreement (BFA). Its purpose is to clarify actions to be taken during the demolition and construction at Brownfields properties in an effort to avoid delays in the event of the discovery of new contamination sources or other environmental conditions. The EMP provides a means to document redevelopment plans and environmental data for each applicable environmental medium to inform regulatory -compliant decision -making at the site. As much detail as possible should be included in the EMP, including contingency planning for unknowns. Consult your project manager if you have questions. Prospective Developers and/or their consultants must complete and submit this form and all pertinent attachments, see checklist below, to their Brownfields project manager prior to any earthmoving or other development -related activities that have the potential to disturb soil at the Brownfields Property, including demolition. For the resultant EMP to be valid for use, it must be completed, reviewed by the program, signed by all parties working on the project, and approved by the Brownfields project manager. Failure to comply with the requirements of the EMP could jeopardize project eligibility, or in the event of a completed agreement, be cause for a reopener So that the EMP provides value in protecting brownfields eligibility and public health, the preparer shall ensure that the following steps have been completed prior to submitting the EMP for review. Any EMP prepared without completing these steps is premature. ® Site sampling and assessment that meets Brownfields' objectives is complete and has been reviewed and approved by the Brownfields Project Manager. ® Specific redevelopment plans, even if conceptual, have been developed for the project, submitted and reviewed by the Brownfields Project Manager. EMP Version 2, June 2018 Please submit, along with the completed EMP form, the following attachments, as relevant and applicable to the proposed redevelopment: ® A set of redevelopment plans, including architectural/engineering plans, if available; if not conceptual plans may suffice if updated when detailed plans are drafted. ® A figure overlaying redevelopment plans on a map of the extent of contamination for each media. ® Site grading plans that include a cut and fill analysis. ® A figure showing the proposed location and depth of impacted soil that would remain on site after construction grading. ® Any necessary permits for redevelopment (i.e. demolition, etc.). ® A detailed construction schedule that includes timing and phases of construction. ® Tabulated data summaries for each impacted media (i.e. soil, groundwater, soil gas, etc.) applicable to the proposed redevelopment. ® Figures with the sampling locations and contamination extents for each impacted media applicable to the proposed redevelopment. ❑ A full final grade sampling and analysis plan, if the redevelopment plan is final. ❑ If known, information about each proposed potential borrow soil source, such as aerial photos, historic site maps, historic Sanborn maps, a site history, necessary for brownfields approval. ® Information and, analytical data if required, for quarries, or other borrow sources, detailing the type of material proposed for importation to the Brownfields Property. ❑ A work plan for the sampling and analysis of soil to be brought onto the Brownfields Property. Refer to Issue Resolution 15 in Brownfields Program Guidelines. ® A map of the Brownfields Property showing the location of soils proposed for export and sampling data from those areas. ® If a Vapor Mitigation System is required by the Brownfields Program, the Vapor Intrusion Mitigation System (VIMS) plan will be signed and sealed by a NC Professional Engineer. The VIMS Plan may also be submitted under separate cover. EMP Version 2, June 2018 Date: 2/25/2021 GENERAL INFORMATION Revision Date (if applicable): Click or tap to enter a date. Brownfields Assigned Project Name: Bookers Garage Brownfields Project Number: 23074-19-060 Brownfields Property Address: 1113 — 1121 Seigle Avenue and 820 E. 151" Street, Charlotte, NC Brownfields Property Area (acres): The Site includes three contiguous parcels (Parcel ID Nos. 08109913, 08109914, and 08109921) totaling approximately 0.53-acres of land. A Site location map is provided as Figure 1, and the Site and surrounding area are shown in Figure 2. Is Brownfields Property Subject to RCRA Permit? ....................... ❑ Yes © No If yes enter Permit No.: Click or tap here to enter text. Is Brownfields Property Subject to a Solid Waste Permit ............ ❑ Yes ® No If yes, enter Permit No.: Click or tap here to enter text. COMMUNICATIONS A copy of this EMP shall be distributed to all the parties below as well as any contractors or site workers that may be exposed to site vapors, soil, groundwater, and/or surface water. Additionally, a copy of the EMP shall be maintained at the Brownfields Property during redevelopment activities. NOTE, THE EMP DOES NOT TAKE THE PLACE OF A SITE -SPECIFIC HEALTH AND SAFETY PLAN. Prospective Developer (PD): 1121 Seigle, LLC Contact Person: Anna Coltrane Phone Numbers: Office: Mobile: (336) 202-6219 Email: anna@spacecraft.city Contractor for PD: Kelly McArdle Construction Contact Person: Danny Kelly Phone Numbers: Office: (704) 344-9411 Mobile: Email: dkelly@kellymcardle.com Environmental Consultant: Hart & Hickman, PC Contact Person: Ralph McGee Phone Numbers: Office: 704-887-4621 Mobile: 704-840-4775 Email: rmcgee@harthickman.com Brownfields Program Project Manager: Kathleen Markey Phone Numbers: Office: Mobile: (919) 707-8378 Email: kathleen.markey@ncdenr.gov 3 EMP Version 2, June 2018 Other DEQ Program Contacts (if applicable, i.e., UST Section, Inactive Hazardous Site Branch, Hazardous Waste, Solid Waste): Brownfields Program - Western District Jordan Thompson Mobile: 704-223-6549 Email: jordan.thompson@ncdenr.gov NOTIFICATIONS TO THE BROWNFIELDS PROGRAM Written advance Notification Times to Brownfields Project Manager: Check each box to accept minimum advance notice periods (in calendar days) for each type of onsitetask: On -site assessment or remedial activities: .................................................... 10 days Prior Construction or grading start: .......................................................................... 10 days Prior Discovery of stained soil, odors, USTs, buried drums or waste, landfill, or other signs of previously unknown contamination: ................................................................................ Within 48 hours El Implementation of emergency actions (e.g. dewatering, flood or soil erosion control measures in area of contamination, ventilation of work zones): ................................... Within 48 hours Installation of mitigation systems: ................................................................ 10 days Prior IK Other notifications as required by local, state or federal agencies toimplement redevelopment activities: (as applicable): ................................................................................. Within 30 days REDEVELOPMENT PLANS 1) Type of Redevelopment (check all that apply): ®Residential ❑Recreational El Institutional ❑Commercial ❑Office ❑Retail ❑ Industrial El Other specify: 2) Check the following activities that will be conducted prior to commencing earth -moving activities at the site: ® Review of historic maps (Sanborn Maps, facility maps) ® Conducting geophysical surveys to evaluate the location of suspect UST, fuel lines, utility lines, etc. ❑ Interviews with employees/former employees/facility managers/neighbors 4 EMP Version 2, June 2018 3) Summary of Redevelopment Plans (MANDATORY: attach detailed plans or conceptual plans, if detailed plans are not available. EMP review without such information would be premature): Provide brief summary of redevelopment plans, including demolition, removal of building slabs/pavement, grading plans and planned construction of new structures: Redevelopment plans for the Site include razing the existing Site buildings (four residential structures) for construction of a multistory high -density luxury residential apartment complex with a multi -story open air parking garage. Grading plans generally include leveling the Site for construction of the apartment complex and parking garage, outdoor amenity area, and access roads. A copy of the most recent redevelopment plan and redevelopment related permits obtained to date are provided in Appendix A. 4) Do plans include demolition of structure(s)?: ® Yes ❑ No ❑ Unknown ® If yes, please check here to confirm that demolition will be conducted in accordance with applicable legal requirements, including without limitation those related to lead and asbestos abatement that are administered by the Health Hazards Control Unit within the Division of Public Health of the North Carolina Department of Health and Human Services. If available, please provide a copy of your demolition permit. 5) Are sediment and erosion control measures required by federal, state, or local regulations? ® Yes ❑ No ❑ Unknown ® If yes, please check here to confirm that demolition will be conducted in accordance with applicable legal requirements. If soil disturbance is necessary to install sediment and erosion control measures, they may not begin until this EMP is approved. 6) Which category of risk -based screening level is used or is anticipated to be specified in the Brownfields Agreement? Note: If children frequent the property, residential screening levels shall be cited in the Brownfields Agreement for comparison purposes. ® Residential ❑ Non -Residential or Industrial/Commercial 7) Schedule for Redevelopment (attach construction schedule): a) Construction start date: 4/1/2021 b) Anticipated duration (specify activities during each phase): A preliminary construction schedule is provided in Appendix B. Initial Site work and grading activities are scheduled to begin in April 2021 and the redevelopment is scheduled to be completed by August 2022. c) Additional phases planned? ❑ Yes ❑ No If yes, specify the start date and/or activities if known: Start Date: Planned Activity: There are no additional phases of redevelopment planned. EMP Version 2, June 2018 Start Date: Click or tap to enter a date. Planned Activity: Mick or tap here to enter text. Start Date: Click or tap to enter a date. Planned Activity: Click or tap here to enter text. d) Provide the planned date of occupancy for new buildings: 8/1/2022 CONTAMINATED MEDIA 1) Contaminated Media on the Brownfields Property Part 1. Soil: .............................................................. ® Yes ❑ No ❑ Suspected Part 2. Groundwater: ............................................ ❑ Yes ® No ❑ Suspected Part 3. Surface Water: .......................................... ❑ Yes ® No ❑ Suspected Part 4. Sediment: ................................................... ❑ Yes ® No ❑ Suspected Part 5. Soil Vapor: .................................................. ® Yes ❑ No ❑ Suspected Part 6. Sub -Slab Soil Vapor: .................................. ❑ Yes ❑ No ❑ Suspected Part 7. Indoor Air: ................................................... ❑ Yes ❑ No ❑ Suspected 2) For the Area of Proposed Redevelopment on the Brownfields Property, attach tabulated data summaries for each impacted media and figure(s) with sample locations. PART 1. Soil — Please fill out the information below, using detailed site plans, if available, or estimate using known areas of contaminated soil and a conceptual redevelopment plan. Provide a figure overlaying new construction onto figure showing contaminated soil and groundwater locations. 1) Known or suspected contaminants in soil (list general groups of contaminants): A tabular summary of available soil sample analytical data in comparison to the North Carolina Department of Environmental Quality (DEQ) Preliminary Soil Remediation Goals (PSRGs) dated July 2020 is included as Table 1. Soil sample locations are shown in Figure 2 and a compound concentration map is provided as Figure 3. A brief summary of the soil assessment results is provided below. Volatile Organic Compounds (VOCs) Laboratory analytical results indicate that no VOCs have been detected in soil samples collected at the Site at concentrations above laboratory method detection limits. Semi -Volatile Oreanic Compounds (SVOCs 6 EMP Version 2, June 2018 Laboratory analytical results indicate that low levels of several SVOCs were detected at concentrations above laboratory method detection limits in soil sample SB-4 collected near the western Site boundary (Figure 2). A trace level of benzo(a)pyrene (0.388 milligrams per kilogram [mg/kg]) was detected at concentration slightly above the DEQ Residential PSRG of 0.11 mg/kg in soil sample SB-4. No other SVOCs have been detected at concentrations above the DEQ Residential PSRGs and no SVOCs have been detected at concentrations above the DEQ Industrial/Commercial PSRGs. Metals Low levels of several metals were detected at concentrations above the laboratory method detection limits in soil samples collected at the Site. The metal concentrations detected were below the DEQ Residential PSRGs and/or consistent with published levels of naturally occurring metals in soil with the exception of the lead concentration detected in drip line soil sample SS-2 (2,310 mg/kg). 2) Depth of known or suspected contaminants (feet): The benzo(a)pyrene concentration detected in soil sample SB-4 was collected from 3 to 4 ft below ground surface (bgs). The lead concentration detected in SS-2 was detected at 0 ft to 1 ft bgs. Benzo(a)pyrene impacts identified near the western Site boundary are expected to be limited to shallow soil along the western side of the former Bookers Garage building. Lead impacts are expected to be limited shallow soil within the drip line of the residence located at 1115 Seigle Avenue. 3) Area of soil disturbed by redevelopment (square feet): Grading will generally be conducted across the entire Site prior to construction (approximately 23,100 sq ft). 4) Depths of soil to be excavated (feet): A cut -fill analysis is provided in Appendix C. Based on review of the cut -fill analysis, cut (up to approximately 9.7 ft) will be needed in the central portions of the Site for construction of the parking garage. Planned cut depths in the northern portion of the property are expected to be up to approximately 5 feet below the current ground surface (ft bgs). Similar cut depths (up to approximately 10 ft bgs) may also be needed in the areas of utility banks and elevator banks for the proposed building. 5) Estimated volume of soil (cubic yards) to be excavated (attach grading plan): Cut -fill analysis indicates that cut for the parking garage is expected to yield approximately 1,500 to 1,600 cubic yards of excess soil. 6) Estimated volume of excavated soil (cubic yards) anticipated to be impacted by contaminants: Based on the results of the soil sampling, the extent of impacted soil is anticipated to be limited to shallow soil in the areas of SB-4 and SS-2 (Figure 3). Cut is not planned in the areas of the SB-4 and SS-2 soil sample locations. The volume of impacted soil disturbed during grading to level the EMP Version 2, June 2018 Site is expected to be less than approximately 50 cubic yards. 7) Estimated volume of contaminated soil expected to be disposed of offsite, if applicable: Impacted or potentially impacted soil is not proposed to be disposed of off -Site. In the unlikely event potentially impacted soil is encountered and cannot be reused on -Site as fill, it will be sampled and managed in accordance with the procedures described in the following sections. Part 1.A. MANAGING ONSITE SOIL If soil is anticipated to be excavated from the Brownfield Property, relocated on the Brownfields Property, or otherwise disturbed during site grading or other redevelopment activities, please provide a grading plan that clearly illustrates areas of cut and fill (approximate areas & volumes are acceptable, if only preliminarydata available). 1) HAZARDOUS WASTE DETERMINATION: a) Does the soil contain a LISTED WASTE as defined in the North Carolina Hazardous Waste Section under 40 CFR Part 261.31-261.35?....................................... ❑Yes ®No ❑ If yes, explain why below, including the level of knowledge regarding processes generating the waste (include pertinent analytical results as needed). 'lick or tap here tr, r+ , + „a ❑ If yes, do the soils exceed the "Contained -Out" levels in Attachment 1 of the North Carolina Contained -In Policy? ................................................. ❑ Yes ❑ No b) NOTE: IF SOIL MEETS THE DEFINITION OF A LISTED HAZARDOUS WASTE AND EXCEEDS THE CONTAINED -OUT LEVELS IN ATTACHMENT 1 TO THE NORTH CAROLINA CONTAINED -IN POLICYTHE SOIL MAY NOT BE RE -USED ON SITE AND MUST BE DISPOSED OF IN ACCORDANCE WITH DEQ HAZARDOUS WASTE SECTION RULES AND REGULATIONS. c) Does the soil contain a CHARACTERISTIC WASTE? .................................... ❑ Yes ® No ❑ If yes, mark reason(s) why below (and include pertinent analytical results). ❑ Ignitability Click or tap here to enter text. ❑ Corrosivity Click or tap here to enter text. ❑ Reactivity Click or tap here to enter text. ❑ Toxicity Click or tap here to enter text. ❑ TCLP results Click or tap here to enter text. ❑ Rule of 20 results (20 times total analytical results for an individual hazardous constituent on TCLP list cannot, by test method, exceed regulatory EMP Version 2, June 2018 TCLP standard) Click or tap here to enter text. ® If no, explain rationale: Laboratory analysis of drip line soil samples (SS-2, SS-3, and SS-4) collected during previous assessment activities indicated the presence of lead at concentrations exceeding the toxicity characteristic hazardous waste criteria using the Rule of 20 (Table 1). Therefore, those soil samples were analyzed for lead utilizing the Toxicity Characteristic Leaching Procedure (TCLP) extraction method. Results of the TCLP analysis did not indicate the presence of lead at concentrations above characteristically hazards levels. A summary of the soil analytical data is provided in Table 1. If soils are disturbed during grading which are suspected to contain concentrations above toxicity characteristic hazardous waste criteria [based on visual observation or field screening with a calibrated photoionization detector (PID)] or the soil will be sampled and managed in accordance with the procedures described below. d) NOTE: IF SOIL MEETS THE DEFINITION OF A CHARACTERISTIC HAZARDOUS WASTE, THE SOIL MAYNOT BE RE -USED ON SITE AND MUST BE DISPOSED OF IN ACCORDANCE WITH DEQ HAZARDOUS WASTE SECTION RULES AND REGULATIONS. 2) Screening criteria by which soil disposition decisions will be made (e.g., left in place, capped in place with low permeability barrier, removed to onsite location and capped, removed offsite): ® Preliminary Health -Based Residential SRGs ❑ Preliminary Health -Based Industrial/Commercial SRGs © Division of Waste Management Risk Calculator (For Brownfields Properties Only) ❑ Site -specific risk -based cleanup level. Please provide details of methods used for determination/explanation. Click or tap here to enter text. Additional comments: Click or tap here to enter text. 3) If known impacted soil is proposed to be reused within the Brownfields Property Boundary, please check the measures that will be utilized to ensure safe placement and documentation of same. Please attach a proposed location diagram/site map. ® Provide documentation of analytical report(s) to Brownfields Project Manager ® Provide documentation of final location, thickness and depth of relocated soil on site map to Brownfields Project Manager once known ❑ Geotextile to mark depth of fill material. EMP Version 2, June 2018 Provide description of material: Click or tap here to enter text. ® Manage soil under impervious cap ® or clean fill ® Describe cap or fill: Documented impacted soils will be covered with impervious surfaces (asphalt pavement, sidewalks, access roads, buildings, etc.) or a minimum of 2 ft of demonstrably clean fill during redevelopment. ® Confer with NC BF Project Manager if Brownfield Plat must be revised (or re -recorded if actions are Post -Recordation). ® GPS the location and provide site map with final location. ❑ Other. Please provide a description of the measure: Click or tap here to enter text. 4) Please describe the following action(s) to be taken during and following excavation and management of site soils: Management of fugitive dust from site ® Yes, describe the method will include: Aside from lead in shallow soil limited to the drip line of one residence and low-level benzo(a)pyrene concentrations in shallow soil west of the former automotive garage, areas of contaminated soil are not expected to be encountered or disturbed during future Site redevelopment activities based upon previous soil sampling data and field screening during previous assessment activities. The grading contractor will take into account conditions such as wind speed, wind direction, and moisture content of soil during soil grading and stockpiling activities to minimize dust generation. Particular attention will be paid by contractors to implement dust control measures as needed based on Site and atmospheric conditions (i.e., by controlled water application, hydro -seeding, and/or mulch, stone, or plastic cover). Potentially impacted soil will be managed as described below. ❑ No, explain rationale: Field Screening of site soil ® Yes, describe the field screening method, frequency of field screening, person conducting field screening: During soil disturbance at the Site, the workers or contractors will observe soils for evidence of potential significantly impacted soil. Evidence of potential significantly impacted soil includes a distinct unnatural color, strong odor, or filled or previously disposed materials of concerns (i.e., chemicals, tanks, drums, etc.). Should the above be noted during Site work, the contractor will contact Hart & Hickman to observe the suspect condition. If Hart & Hickman confirms that the material may be impacted, then the procedures below will be implemented. In addition, Hart & Hickman will contact the DEQ 10 EMP Version 2, June 2018 Brownfields project manager within 48-hours to advise that person of the condition. ❑ No, explain rationale: Soil Sample Collection ❑ Yes, describe the sampling method (e.g., in -situ grab, composite, stockpile, etc.): ® No, explain rationale: In the unlikely event unknown significant soil impact is encountered during grading and/or installation or removal of utilities, excavation will proceed only as far as needed to allow grading and/or construction of the utility to continue and/or only as far as needed to allow alternate corrective measures described below. Suspect significantly impacted soil excavated during grading and/or utility line installation or removal may be stockpiled and covered in a secure area to allow construction to progress. Suspect impacted soil will be underlain by and covered with minimum 10-mil plastic sheeting as shown in the Figure on the final page of the EMP form below. At least one representative soil sample (no less than 3 aliquot soil samples at a sample ratio of 1 soil sample per every approximately 1,000 cubic yards of soil) will be collected for analysis of total VOCs, SVOCs, and RCRA metals (note the VOC sample will be a grab sample from one aliquot soil sample). If the results of analysis of the sample indicate that the soil could potentially exceed toxicity characteristic hazardous waste criteria, then the soil will also be analyzed by TCLP methods for those compounds that could exceed the toxicity characteristic hazardous waste criteria. Impacted soil will be managed in the manner described below based upon the laboratory analyses: If no organic compounds are detected in a sample (other than which are attributable to sampling or laboratory artifacts) and metals are below the Protection of Groundwater or Residential PSRG (whichever is lower for the detected compounds) and are consistent with Site -specific background levels, then the soil will be deemed suitable for use as on -Site fill or as off -Site fill. The proposed location(s) for off -Site placement of soil (other than a permitted facility) along with receiving facility written approval for acceptance of the soil will be provided to DEQ for approval prior to transporting soil off - Site. ii. If detectable levels of compounds are found which do not exceed the DEQ IHSB Residential PSRGs (other than which are attributable to sampling or laboratory artifacts or which are consistent with Site -specific background levels for metals) and the TCLP concentrations are below hazardous waste criteria, then the soil may be used on -Site as fill without conditions. iii. If detectable levels of compounds are found which exceed the DEQ IHSB Residential PSRGs (other than which are attributable to sampling or laboratory artifacts or which are consistent with background levels for metals) and the TCLP concentrations are below hazardous waste criteria, then the soil, with DEQ written approval, may be used 11 EMP Version 2, June 2018 on -Site as fill below an impervious surface, or at least 2 ft of verified compacted clean soil. If the impacted soil with concentrations above Residential PSRGs is moved to an on -Site location, its location and depth will be documented, and its location will be provided to DEQ. iv. Impacted soil may be transported to a permitted facility such as a Municipal Solid Waste landfill or DEQ permitted landfarm for petroleum impacted soil provided that the soil is accepted at the disposal facility. Permitted facilities do not include C&D or LCID landfills. If soil is transported to a facility permitted to accept contaminated soil, written approval from the facility to dispose of soil from the Site will be included with the final redevelopment report. In the unlikely event that the sample data indicates concentrations above TCLP hazardous waste criteria, then the soil must be transported off -site to a permitted disposal facility that can accept or treat hazardous waste. *Please note that should the PD elect to transport export soil to a permitted facility or to a DEQ Brownfields pre -approved receiving facility, soil will be direct loaded onto trucks for transport off -Site. If soil samples are collected for analysis, please check the applicable chemical analytes: ® Volatile organic compounds (VOCs) by EPA Method 8260 ® Semi -volatile organic compounds (SVOCs) by EPA Method 8270 ® Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver): Specify Analytical Method Number(s): EPA Methods 6020/7471 ❑ Pesticides: Specify Analytical Method Number(s): Click or tap here to enter text. ❑ PCBs: Specify Analytical Method Number(s): Clio< or tap here to enter text. ® Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.): Specify Analytical Method Number(s): Hexavalent Chromium by EPA Method 7199 ® Check to confirm that stockpiling of known or suspected impacted soils will be conducted in accordance with Figure 1 of this EMP. Stockpile methodology should provide erosion control, prohibiting contact between surface water/precipitation and contaminated soil, and preventing contaminated runoff. Explain any variances or provide additional details as needed: As noted above, soil planned for export to a permitted facility or to a DEQ Brownfields pre -approved receiving facility will be direct loaded onto trucks for transport off -Site in lieu of stockpiling. If known or potentially impacted soil needs to be temporarily stockpiled on -Site, stockpiling will be conducted in accordance with methods shown in EMP Figure 1. 12 EMP Version 2, June 2018 ® Final grade sampling of exposed native soil (i.e., soil that will not be under buildings or permanent hardscape). Select chemical analyses for final grade samples with check boxes below (Check all thatapply): ® Volatile organic compounds (VOCs) by EPA Method 8260 ® Semi -volatile organic compounds (SVOCs) by EPA Method 8270 ® Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver): Specify Analytical Method Number(s): EPA Methods 6020/7471. ❑ Pesticides: Specify Analytical Method Number(s): ❑ PCBs: Specify Analytical Method Number(s): ® Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.): Hexavalent Chromium by EPA Method 7199 Please provide a scope of work for final grade sampling, including a diagram of soil sampling locations, number of samples to be collected, and brief sampling methodology. Samples should be collected from 0-2 ft below ground surface, with the exception of VOCs which should be taken from 1-2 ft below ground surface. Alternatively, a work plan for final grade sampling may be submitted under separate cover. Following completion of soil disturbance for future Site development (i.e., after grading and utility construction), Hart & Hickman will observe the Site for areas that will not be covered upon completion of the redevelopment with a minimum of 2 ft of documented clean fill soil, building foundations, sidewalks, asphalt or concrete parking areas and driveways, or other similar impervious areas (e.g., tightly spaced pavers or bricks). If such areas exist, a Work Plan will be prepared for final grade soil sampling for DEQ Brownfields review and approval. Based on the current Site redevelopment plan, one final grade soil sample will be collected for laboratory analysis for each approximately 100 ft of linear landscape area or every approximately 1,000 sq ft of open area. If no such areas exist, documentation will be provided to the DEQ Brownfields project manager. Final grade soil samples will consist of a maximum of five (5) aliquot soil samples collected from within each evaluation area which will be combined and homogenized to form one composite soil sample representative of that evaluation area and submitted for analysis of SVOCs and RCRA metals plus hexavalent chromium. In addition, one grab soil sample will be collected for each evaluation area and submitted for laboratory analysis of VOCs. ❑ If final grade sampling was NOT selected please explain rationale: 13 EMP Version 2, June 2018 Part 1.13. IMPORTED FILL SOIL NO SOIL MAY BE BROUGHT ONTO THE BROWNFIELDS PROPERTY WITHOUT PRIOR APPROVAL FROM THE BROWNFIELDS PROGRAM. According to the Brownfields IR 15, "Documenting imported soil (by sampling, analysis, and reporting in accordance with review and written approval in advance by the Brownfields Program), will safeguard the liability protections provided by the brownfields agreement and is in the best interest of the prospective developer/property owner." Requirements for importing fill: 1) Will fill soil be imported to the site? ................................................ ❑ Yes ® No ❑ Unknown 2) If yes, what is the estimated volume of fill soil to be imported? Results of preliminary analysis indicate that mass grading will result in a net export with no planned import of soil. 3) If yes, what is the anticipated depth that fill soil will be placed at the property? (If a range of depths, please list the range.) In general, fill areas are located in the southern/southwestern portions of the Site nearest Seigle Avenue (up to approximately 7.5 ft) with a small area of fill located north of the parking deck (up to 7.5 ft). Soil cut in areas of the proposed parking deck in central portions of the Site will be used as fill to meet the proposed final grade elevations. 4) Provide the source of fill, including: location, site history, nearby environmental concerns, etc. Attach aerial photos, maps, historic Sanborn maps and a borrow source site history: Where possible, the soil from the cut areas will be utilized in the fill areas on -Site. If the PD plans to import fill material, the source will be a known quarry (i.e., Vulcan Materials Company quarry located near Pineville, NC or Martin Marietta quarries located on Beatties Ford Road and/or Arrowood Road in Charlotte, NC). Alternatively, if the PD elects to not import soil from a known quarry, upon determination of the borrow source, DEQ will be notified and the procedures outlined below will be implemented. 5) PRIOR TO ITS PLACEMENT AT THE BROWNFIELDS PROPERTY, provide a plan to analyze fill soil to demonstrate that it meets acceptable standards applicable to the site and can be approved for use atthe Brownfields property. The PD plans to import limited amounts of virgin organic rich topsoil from a commercial landscape material vendor for use in proposed landscaped areas. The PD does not plan to collect samples of landscaping materials prior to placement at the Site. In addition, the PD may use limited amounts of lime or concrete as an amending agent for drying soil as needed during grading and redevelopment activities. The PD does not plan to collect samples of lime or concrete used as an amending agent prior to use at the Site. 14 EMP Version 2, June 2018 If soil is imported from quarry that has been pre -approved for import to Brownfields properties, soil samples will not be collected prior to placement on Site. For import soil needed during grading that is sourced from an unapproved borrow site, the procedures outlined below will be followed to demonstrate import soil meets acceptable standards applicable to the Site. 6) Please check the applicable chemical analytes for fill soil samples. (Check all that apply): ® Volatile organic compounds (VOCs) by EPA Method 8260 ® Semi -volatile organic compounds (SVOCs) by EPA Method 8270 ® Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver): Specify Analytical Method Number(s): EPA Methods 6020/7471 ❑ Pesticides: Specify Analytical Method Number(s): ❑ PCBs: Specify Analytical Method Number(s): ® Other Constituents & Respective Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.): Hexavalent Chromium by EPA Method 7199 7) The scope of work for import fill sampling may be provided below or in a Work Plan submitted separately for DEQ review and approval. Attach specific location maps for in -situ borrow sites. If using a quarry, provide information on the type of material to be brought onto the Brownfields Property. The PD will follow the procedures outlined below to demonstrate import soil meets acceptable standards applicable to the Site. If the PD obtains soil from an off -Site property that is not a quarry that has been pre -approved for import to a Brownfields property, a sampling plan will be developed and submitted for DEQ review. DEQ approval of the sampling plan and analytical results will be obtained prior to transporting import soil to the Site. The specific sampling rate will be outlined in the aforementioned sampling plan. However, if the proposed borrow source has not been previously developed (i.e., virgin land), soil samples will be collected for laboratory analyses indicated above at a general rate of one per 1,000 cubic yards. If the borrow source property has been previously developed, soil samples will be collected for laboratory analyses indicated above at a general rate of approximately one per 500 cubic yards. Fill soil will be considered suitable for use at the Site if it does not contain compound concentrations above DEQ Residential PSRGs, DWM Risk Calculator risk thresholds, or typical metals concentrations which are consistent with background levels identified at the Site. 15 EMP Version 2, June 2018 Part 1.C. EXPORTED SOIL NO SOIL MAY LEAVE THE BROWNFIELDS PROPERTY WITHOUT APPROVAL FROM THE BROWNFIELDS PROGRAM. FAILURE TO OBTAIN APPROVAL MAY VIOLATE A BROWNFIELDS AGREEMENT CAUSING A REOPENER OR JEOPARDIZING ELIGIBILITY IN THE PROGRAM, ENDANGERING LIABILITY PROTECTIONS AND MAKING SAID ACTION POSSIBLY SUBJECT TO ENFORCEMENT. JUSTIFICATIONS PROVIDED BELOW MUST BE APPROVED BY THE PROGRAM IN WRITING PRIOR TO COMPLETING TRANSPORT ACTIVITIES. Please refer to Brownfields IR 15 for additional details. 1) If export from a Brownfields Property is anticipated, please provide details regarding the proposed export actions. Volume of exported soil, depths, location from which soil will be excavated on site, related sampling results, etc. Provide a site map with locations of export and sampling results included. As noted above, preliminary analysis indicates that cut in central portions of the Site for construction of the parking deck are likely to yield up to approximately 1,600 cubic yards of excess soil that cannot be used as fill on -Site. Prior to transporting excess soil off -Site, a sampling plan will be developed and submitted to DEQ Brownfields for review and approval once the volume of soil for export is known. Results of previous soil assessment activities did not identify soil impacts in the central portion of the Site. Therefore, it is expected that soil samples will be collected from export soil at a rate of 1 composite sample consisting of 3 to 5 soil sample aliquots for every approximately 1,000 cubic yards of export. DEQ approval of the sampling plan and analytical results will be obtained prior to transporting export soil from the Site. Based on analytical results of soil samples collected from the export soil, the soil will be transported off -Site to a suitable location. The PD will notify DEQ Brownfields of the location receiving the export soil. If not a permitted facility (e.g., permitted landfarm or Subtitle D landfill), DEQ Brownfields approval and written approval from the receiving facility will be obtained prior to transporting the soil off -Site. 2) To what type of facility will the export Brownfields soil be sent? ® Subtitle D/Municipal Solid Waste Landfill (analytical program to be determined by landfill) ® Permitted but Unlined Landfill (i.e. LCID, C&D, etc.) Analytical program to be determined by the accepting Landfill; ® Landfarm or other treatment facility ® Use as fill at another suitable Brownfields Property — determination that a site is suitable will require, at a minimum, that similar concentrations of the same or similar contaminants already exist at both sites, use of impacted soil will not increase the potential for risk to human health and the environment at the receiving Brownfields property, and thata record of the acceptance of such soil from the property owner of the receiving site is provided to Brownfields. Please provide additional details below. 16 EMP Version 2, June 2018 ® Use as Beneficial Fill off -site at a non-Brownfields Property - Please provide documentation of approval from the property owner for receipt of fill material. This will also require approval by the DEQ Solid Waste Section. Additional information is provided in IR 15. Please provide additional details below. 3) Additional Details: (if transfer of soil to another property is requested above, please provide details related to the proposed plans). Hart & Hickman will contact DEQ Brownfields to obtain DEQ Brownfields and DEQ Solid Waste approval prior to exporting soil to a non-Brownfields property or to a facility that is not a Municipal Solid Waste landfill or DEQ permitted landfarm for petroleum impacted soil. Part 1.D. MANAGEMENT OF UTILITY TRENCHES ❑ Install liner between native impacted soils and base of utility trench before filling with clean fill (Preferred) ® Last out, first in principle for impacted soils (if soil can safely be reused onsite and is not hazardous waste), i.e., impacted soils are placed back at approximately the depths they were removed from such that impacted soil is not placed at a greater depth than the original depth from which it was excavated. ® Evaluate whether necessary to install barriers in conduits to prevent soil vapor transport, and/or degradation of conduit materials due to direct impact with contaminants? ® If yes, provide specifications on barrier materials: Results of soil gas assessment activities completed within the proposed building footprint indicate that TCE is present at low concentrations above the DEQ Division of Waste Management (DWM) Residential Vapor Intrusion Sub -slab and Exterior Soil Gas Screening Levels (SGSLs). Therefore, the developer plans to proactively install a passive vapor intrusion mitigation system (VIMS) during construction of the proposed apartment building. As part of the VIMS design, the locations of sub -grade utilities will be evaluated to confirm that the proposed VIMS will effectively minimize potential vapor intrusion from soil vapor associated with groundwater impacts potentially migrating preferentially through sub -grade conduits. ❑ If no, include rationale here: Other comments regarding managing impacted soil in utility trenches: The contractor and workers will observe soil for potential impacts during utility installation activities. Evidence of potential significant impacted soil includes a distinct unnatural color, strong odor, or filled or previously disposed materials of concerns (i.e., chemicals, tanks, drums, etc.). Should the above be noted during utility work, the contractor will contact Hart & Hickman to observe the suspect condition. If Hart & Hickman confirms that the material may be impacted, then the procedures outlined in Managing On -Site Soil above will be implemented. In addition, Hart & Hickman will 17 EMP Version 2, June 2018 contact the DEQ Brownfields project manager within 48-hours to advise that person of the condition. Should impacted soil be discovered during utility trenching activities, appropriate safety screening will be performed by an environmental professional to protect workers during utility installation activities. Safety screening activities include monitoring the worker breathing zone with a calibrated photoionization detector or similar instrument at all times when in utility trenches. If safety screening results indicate further action is warranted, the work zone will be evacuated until appropriate engineering controls (such as use of industrial fans) are implemented. PART 2. GROUNDWATER — Please fill out the information below. 1) What is the depth to groundwater at the Brownfields Property? During previous assessment activities conducted at the Site in November 2019, August 2020, and October 2020, the potentiometric groundwater surface was measured at depths ranging from approximately 13 ft bgs to 16 ft bgs. Locations of the temporary monitoring wells are shown in Figure 2. 2) Is groundwater known to be contaminated by ❑onsite ❑offsite ®both or ❑unknown sources? Describe source(s): Tabular summary of the analytical data for groundwater samples collected at the Site is provided as Table 2. Groundwater sample locations are shown in Figure 2. As shown in Table 2, no compounds have been detected at concentrations above the DEQ 2L Groundwater Quality Standards (2L Standards) or the DEQ DWM Vapor Intrusion Groundwater Screening Levels (GWSLs). 3) What is the direction of groundwater flow at the Brownfields Property? Based on measured water levels at the Site, shallow groundwater is estimated to mimic surface topography and flow generally toward the west-northwest toward Little Sugar Creek located approximately northwest of the Site. 4) Will groundwater likely be encountered during planned redevelopment activities? ❑Yes ®No If yes, describe these activities: It is not expected that shallow groundwater will be encountered during utility installations or other construction related activities. If groundwater is encountered during redevelopment activities, the procedures outlined below will be implemented. Regardless of the answer; in the event that contaminated groundwater is encountered during redevelopment activities (even if no is checked above), list activities for contingent management of groundwater (e.g., dewateringof groundwater from excavations or foundations, containerizing, offsite disposal, discharge to sanitary sewer, NPDES permit, or sampling procedures). Should groundwater be encountered, the contractors will contact an environmental professional to observe conditions to determine if there are impacts that may pose a potential risk to workers. Appropriate worker safety measures will be undertaken if groundwater gathers 18 EMP Version 2, June 2018 in an open excavation within an area determined to be impacted during construction activities. The accumulated water will be allowed to evaporate/infiltrate to the extent time for dissipation does not disrupt the construction schedule. Should the time needed for natural dissipation of accumulated water be deemed inadequate, the water will be tested and disposed off -Site (if impacted), or tested and discharged to the stormwater retention systems (if not impacted above DEQ surface water quality standards) in accordance with applicable municipal and State regulations for erosion control and construction stormwater control. 5) Are monitoring wells currently present on the Brownfields Property?.................❑Yes ®No If yes, are any monitoring wells routinely monitored through DEQ or other agencies?..................................................................................................................❑Yes ❑No 6) Please check methods to be utilized in the management of known and previously unidentified wells. ® Abandonment of site monitoring wells in accordance with all applicable regulations. It is the Brownfields Program's intent to allow proper abandonment of well(s) as specified in the Brownfields Agreement, except if required for active monitoring through another section of DEQ or the EPA. ❑ Location of existing monitoring wells marked ❑ Existing monitoring wells protected from disturbance ® Newly identified monitoring wells will be marked and protected from further disturbance until notification to DEQ Brownfields can be made and approval for abandonment is given. 7) Please provide additional details as needed: DEQ will be notified if newly identified monitoring wells are found on the Brownfields property. Please note. disturbance of existing site monitoring wells without aaaroval by DEQ is not Dermissible. If monitoring wells are damaged and/or destroved. DEQ may reauire that the PD be responsible for replacement of the well. PART 3. SURFACE WATER -Please fill out the information below. 1) Is surface water present at the property? ❑ Yes ® No 2) Attach a map showing the location of surface water at the Brownfields Property. 3) Is surface water at the property known to be contaminated? ❑ Yes ® No 4) Will workers or the public be in contact with surface water during planned redevelopment activities? ❑ Yes ® No 5) In the event that contaminated surface water is encountered during redevelopment activities, or clean surface water enters open excavations, list activities for management of such events (e.g. flooding, contaminated surface water run-off, stormwater impacts): 19 EMP Version 2, June 2018 As noted above, when excavating during construction activities at the Site, the workers or contractors will observe soils for evidence of potential significantly impacted soil including a distinct unnatural color, strong odor, or filled or previously disposed materials of concerns (i.e., chemicals, tanks, drums, etc.). If surface water run-off gathers in an open excavation within an area determined to be impacted during construction activities, appropriate worker safety measures will be undertaken. The accumulated water will be allowed to evaporate/infiltrate to the extent time for dissipation does not disrupt the construction schedule. Should the time needed for natural dissipation of accumulated water be deemed inadequate, the water will be tested and disposed off -Site (if impacted), or tested and discharged to the storm sewer (if not impacted above DEQ surface water standards) in accordance with applicable municipal and State regulations for erosion control and construction stormwater control. PART 4. SEDIMENT — Please fill out the information below. 1) Are sediment sources present on the property? ❑ Yes ® No 2) If yes, is sediment at the property known to be contaminated: ❑ Yes ® No 3) Will workers or the public be in contact with sediment during planned redevelopment activities? ❑ Yes ® No 4) Attach a map showing location of known contaminated sediment at theproperty. 5) In the event that contaminated sediment is encountered during redevelopment activities, list activities for management of such events (stream bed disturbance): Not Applicable PART 5. SOIL VAPOR — Please fill out the information below. 1) Do concentrations of volatile organic compounds at the Brownfields property exceed the following vapor intrusion screening levels (current version) in the following media: IHSB Residential Screening Levels: Soil Vapor:...........® Yes ❑ No ❑ Unknown Groundwater: ..... ❑ Yes ® No ❑ Unknown IHSB Industrial/Commercial Screening Levels: Soil Vapor: ........... ❑ Yes ® No ❑ Unknown Groundwater: ..... ❑ Yes ® No ❑ Unknown 2) Attach a map showing the locations of soil vapor contaminants that exceed site screening levels. 20 EMP Version 2, June 2018 3) If applicable, at what depth(s) is soil vapor known to be contaminated? Twelve soil gas samples have been collected within the footprint of the proposed building. Soil gas sample locations are shown in Figure 2 and a compound concentration map is provided as Figure 3. A tabular summary of the soil gas sample laboratory analytical results is provided as Table 3. Laboratory analytical results indicate that several VOCs were detected at concentrations above the laboratory method detection limits in each of the soil gas samples. Low levels of TCE (up to 46 micrograms per cubic meter [µg/m3]) were detected in the northwestern and central portions of the Site within the footprint of the proposed open air parking garage. No compounds have been detected at concentrations above the DEQ DWM Vapor Intrusion SGSLs within the footprint of ground -level occupiable components of the proposed building (see Figure 3). 4) Will workers encounter contaminated soil vapor during planned redevelopment activities? ❑ Yes ❑ No ® Unknown 5) In the event that contaminated soil vapor is encountered during redevelopment activities (trenches, manways, basements or other subsurface work,) list activities for management of such contact: As noted above, appropriate safety screening will be performed by an environmental professional to protect workers during utility installation activities in areas of known impacted groundwater that may impact soil vapor at unacceptable levels. Safety screening activities include monitoring the worker breathing zone with a calibrated photoionization detector or similar instrument on an as needed basis based on groundwater and/or vapor impacts identified during the utility installation activities. If safety screening results indicate further action is warranted, the work zone will be evacuated until appropriate engineering controls (such as use of industrial fans) are implemented. PART 6. SUB -SLAB SOIL VAPOR — Please fill out the information below if existing buildings or foundations will be retained in the redevelopment. 1) Are sub -slab soil vapor data available for the Brownfields Property? ❑ Yes © No ❑ Unknown 2) If data indicate that sub -slab soil vapor concentrations exceed screening levels, attach a map showing the location of these exceedances. 3) At what depth(s) is sub -slab soil vapor known to be contaminated? ❑0-6 inches ❑Other, please describe: Not Applicable. 4) Will workers encounter contaminated sub -slab soil vapor during planned redevelopment activities? ❑ Yes ❑ No ® Unknown 5) In the event that contaminated soil vapor is encountered during redevelopment activities, list activities for management of such contact 21 EMP Version 2, June 2018 In the unlikely event impacted soil vapors are encountered during future redevelopment activities, worker breathing zone will be monitored using a calibrated photoionization detector. If results indicate further action is warranted, appropriate engineering controls (such as use of industrial fans) will be implemented. Impacted soil vapors will be determined by contractor olfactory awareness, observations, and monitoring for worker symptoms such as lightheadedness. PART 7. INDOOR AIR — Please fill out the information below. 1) Are indoor air data available for the Brownfields Property? ❑ Yes ® No ❑ Unknown 2) Attach a map showing the location(s) where indoor air contaminants exceed site screening levels. 3) If the structures where indoor air has been documented to exceed risk -based screening levels will not be demolished as part of redevelopment activities, will workers encounter contaminated indoor air during planned redevelopment activities? ❑ Yes ❑ No ® Unknown 4) In the event that contaminated indoor air is encountered during redevelopment activities, list activities for management of such contact: In the unlikely event there is evidence of potential indoor air issues (i.e., unusual odors) during future redevelopment activities, the area will be evacuated and appropriate safety screening of the indoor air will be performed. If warranted, safety screening procedures will be conducted by an environmental professional and will include periodically screening by an environmental professional indoor air for volatile organic vapors with a calibrated photoionization detector when workers present in the Site buildings identify potential indoor air issues. If results indicate further action is warranted, appropriate engineering controls (such as use of industrial fans) will be implemented. VAPOR INTRUSION MITIGATION SYSTEM — Please fill out the information below. Is a vapor intrusion mitigation system (VIMS) proposed for this Brownfields Property? ® Yes ❑ No ❑ Unknown If yes, ❑ VIMS Plan Attached or ® VIMS Plan to be submitted separately If submitted separately provide date: The PD proposes to proactively install a vapor intrusion mitigation system (VIMS) during construction of the proposed Site building in accordance DEQ Brownfields approved VIMS Plan. The VIMS Plan will be submitted to DEQ for review and approval under separate cover prior to construction of proposed Site building. VIMS Plan shall be signed and sealed by a NC Professional Engineer 22 EMP Version 2, June 2018 If no, please provide a brief rationale as to why no vapor mitigation plan is warranted: CONTINGENCY PLAN — encountering unknown tanks, drums, or other waste materials In this section please provide actions that will be taken to identify or manage unknown potential new sources of contamination. During redevelopment activities, it is not uncommon that unknown tanks, drums, fuel lines, landfills, orother waste materials are encountered. Notification to DEQ Brownfields Project Manager, UST Section, Fire Department, and/or other officials, as necessary and appropriate, is required when new potential source(s) of contamination are discovered. These Notification Requirements were outlined on Page 1 of this EMP. Should potentially impacted materials be identified that are inconsistent with known site impacts, the DEQ Brownfields Project Manager will be notified and a sampling plan will be prepared based on the EMP requirements and site -specific factors. Samples will generally be collected to document the location of the potential impacts. Check the following chemical analysis that are to be conducted on newly identified releases: ® Volatile organic compounds (VOCs) by EPA Method 8260 ® Semi -volatile organic compounds (SVOCs) by EPA Method 8270 ® Metals RCRA List (8) (arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver) EPA Methods 6020/7471. ❑ Pesticides: Specify Analytical Method Number(s): r1,,.1, - }ap here *- r+ . *-,,' ❑ PCBs: Specify Analytical Method Number(s): Click or tap here to enter text ® Other Constituents & Analytical Method(s) (i.e. Hexavalent Chromium, Herbicides, etc.) Please note, if field observations indicate the need for additional analyses, they should be conducted, even if not listed here. Hexavalent Chromium by EPA Method 7199 Please provide details on the proposed methods of managing the following commonly encountered issues during redevelopment of Brownfields Properties. During construction activities, contractors may encounter unknown sub -surface environmental conditions (i.e., tanks, drums, or waste materials) that if encountered, will require proper management. Prior to beginning Site work, Hart & Hickman will attend a pre -construction kick-off meeting with the PD and the redevelopment contractors to discuss the DEQ approved EMP and various scenarios when it would be appropriate and necessary to notify H&H of the discovery of 23 EMP Version 2, June 2018 unknown subsurface features or potentially impacted media at the Site. In the event that such conditions are encountered during redevelopment activities, the environmental actions noted below will be used to assist in appropriate management of sub -surface environmental conditions and determination of the most suitable final disposition of potentially impacted Site media. Underground Storage Tanks: In the event that an unknown UST or impacts associated with a UST release are discovered at the Site during redevelopment activities, the UST and/or UST related impacts will be addressed through the Brownfields Program. DEQ Brownfields will be notified within 48-hours of discovery of the UST. If an unknown UST is encountered, the UST will be removed, if possible, and transported off -Site for disposal at a suitable facility. Prior to removing the UST from the ground, residual fluids, if any, will be sampled for VOCs, SVOCs, and RCRA metals as needed for disposal purposes. If a UST is encountered that cannot be removed, it may be abandoned in -place with prior DEQ approval and construction will proceed. Where appropriate, the bottom of the UST may be penetrated before abandonment to prevent fluid accumulation. Impacted soil in the vicinity of the UST will be managed in accordance with the Managing On -Site Soil section outlined in this EMP. Sub -Grade Feature/Pit: If a sub -grade feature or pit is encountered, it will be removed from the Site, if possible and construction will proceed. Where appropriate, the bottom may be penetrated before back filling to prevent fluid accumulation. If the pit has waste in it, the waste will be set aside in a secure area and will be sampled for waste disposal purposes for TCLP VOCs, TCLP SVOCs, and TCLP metals and disposed off -Site at a permitted facility or the waste will be managed in accordance with the Managing On -Site Soil section outlined above in the EMP, whichever is most applicable based on the type of waste present. If the pit must be removed and the observed waste characteristics indicate the concrete may potentially be contaminated to a significant degree, the concrete will be sampled and analyzed by methods specified by the disposal facility Buried Waste Material: If excavation into buried wastes or significantly impacted soils occurs, the contractor is instructed to stop work in that location and notify Hart & Hickman. Hart & Hickman will observe the suspect materials and collect samples for laboratory analysis, if warranted. Confirmation sampling will be conducted at representative locations in the base and the sidewalls of the excavation after the waste or significantly impacted soil is removed. The confirmation samples will be analyzed for VOCs, SVOCs, and RCRA metals (or other analyses as appropriate based on the type of waste material). Information will be provided to DEQ Brownfields regarding the type of waste material discovered to determine if sampling for methane in soil gas is warranted. Information regarding the permitted facility used for disposal of the waste or significantly impacted soil will also be provided to DEQ. Areas of suspected contaminated soil that remain at the Site after excavation is complete above the DEQ IHSB Residential PSRGs will be managed pursuant to this plan. 24 EMP Version 2, June 2018 Re -Use of Impacted Soils On -Site: Please refer to description outlined in the Managing On -Site Soil section of the EMP above. . If unknown, impacted soil is identified on -site, management on -site can be considered after the project team provides the necessary information, outlined in Part 1.A. Item 11, for Brownfields Project Manager approval prior to final placement on -site. If other potential contingency plans are pertinent, please provide other details or scenarios as needed below: POST -REDEVELOPMENT REPORTING ® Check this box to acknowledge that a Redevelopment Summary Report will be required for the project. If the project duration is longer than one year, an annual update is required and will be due by January 31 of each year, or 30 days after each one-year anniversary of the effective date of this EMP (as agreed upon with the Project Manager). These reports will be required for as long as physical redevelopment of the Brownfields Property continues, except that the final Redevelopment Summary Report will be submitted within 90 days after completion of redevelopment. Based on the estimated construction schedule, the first Redevelopment Summary Report is anticipated to be submitted on 1/31/2022 The Redevelopment Summary Report shall include environment -related activities since the last report, with a summary and drawings, that describes: 1. actions taken on the Brownfields Property; 2. soil grading and cut and fill actions; 3. methodology(ies) employed for field screening, sampling and laboratory analysis of environmental media; 4. stockpiling, containerizing, decontaminating, treating, handling, laboratory analysis and ultimate disposition of any soil, groundwater or other materials suspected or confirmed to be contaminated with regulated substances; and 5. removal of any contaminated soil, water or other contaminated materials (for example, concrete, demolition debris) from the Brownfields Property (copies of all legally required manifests shall be included). ❑X Check box to acknowledge consent to provide a NC licensed P.G. or P.E. sealed, Redevelopment Summary Report in compliance with the site's Brownfields Agreement. 25 EMP Version 2, June 2018 APPROVAL SIGNATURES Brownfields Project Number: 23074-19-060 Brownfields Project Name: Bookers Garage Prospective Developer: 1121 Seigle, LLC Printed Name/Title/Company: Harrison Tucker, Manager of CoHab Development, LLC DBA Space Craft, the Manager of 1121 Seigle, LLC Consultant: Hart & fiickman Printed Name/Title/Company: Ralph McGee Brownfields Project Manager: Kathleen Markey 26 EMP Version 2, June 2018 3/29/21 Date Click or tap to enter a date. March 26, 2021 Date Click or tap to enter a date. March 25, 2021 Date Click or tap to enter a date. Figure 1 NCBP Diagram for Temporary Containment of Impacted or Potentially Impacted Soil Cross -Section View Top Plastic Cover Sheeting: Underliner: 1 layer, minimum of 10 (1 Layer, minimum: 10 mil thick) mil thick plastic Berm (Straw bales, composted earth, etc.) Land Surface \ x Straw Bale Berm Contaminated Soils Map View Uo o0*1- - -37 �L.. ""' Contaminated Soils Weight (If plastic cover used) Weight ....................................................... aO Plastic Sheeting Note: Adapted from NC DEQ UST Section "Guidelines for Ex Situ Petroleum Contaminated Soil Remediation" dated December, 1, 2013 27 EMP Version 2, June 2018 Tables hart ` hickman SMARTER ENVIRONMENTAL SOLUMNS Table 1 Summary of Soil Analytical Data Bookers Garage Charlotte, North Carolina H&H Job No. SCF-001 Sample Location Bookers Garage Building Near Residences Industrial/ Regional Background Characteristic Sample ID p SB-1 SB-2 SB-3 SB-4 SS-1 / SS-DUP Residential PSRGs Commercial Metals in Soil c2> Hazardous Waste Threshold Level Date 11/8/19 11/8/19 11/8/19 11/8/19 08/12/20 PSRGs �'� (3) Depth (ft bgs) 3-4 3-4 3-4 3-4 3-5 Range Mean Units mg/kg mg/L VOCs (8260D) ALL BDL ALL BDL ALL BDL ALL BDL ALL BDL ALL BDL -- -- -- -- -- SVOCs (8270E) Acenaphthene <0.415 <0.418 <0.416 0.432 <0.0989 <0.0986 720 9,000 -- -- -- Benzo(a)anthracene <0.415 <0.418 <0.416 0.421 <0.122 <0.122 1.1 21 -- -- -- Benzo(a)pyrene <0.415 <0.418 <0.416 0.388 <0.167 <0.166 0.11 2.1 -- -- -- Benzo(b)fluoranthene <0.415 <0.418 <0.416 0.753 <0.155 <0.154 1.1 21 -- -- -- Benzo(g,h,i)perylene <0.415 <0.418 <0.416 0.481 <0.150 <0.150 NE NE -- -- -- Chrysene <0.415 <0.418 <0.416 0.446 <0.112 <0.111 110 2,100 -- -- -- Fluoranthene <0.415 <0.418 <0.416 0.411 <0.116 <0.116 480 6,000 -- -- -- Indeno(1,2,3-cd)pyrene <0.415 <0.418 <0.416 0.403 <0.176 <0.175 1.1 21 -- -- -- Pyrene <0.415 <0.418 <0.416 0.585 <0.106 <0.105 360 4,500 -- -- -- Metals (6010D/7199/7471 B) -- Arsenic <1.1 2.3 1.8 2.0 1.9 1.4 0.68 3.0 1.0 - 18 4.8 -- Barium 40.6 45.1 179 47.2 56.3 57.1 3,100 47,000 50 - 1,000 356 -- Cadmium <0.11 <0.096 0.14 <0.11 0.45 0.46 14 200 1.0 - 10 4.3 -- Chromium (total) 5.7 18.6 9.3 10.6 24.6 26.7 NE NE 7.0 - 300 65 -- Hexavalent Chromium NA NA NA NA <0.295 0.31 6.5 NS NS -- Trivalent Chromium 5.7 18.6 9.3 10.6 24.6 26.7 23,000 350,000 NS NS -- Lead 4.2 6.5 9.9 32.7 14.1 13.8 400 800 ND - 50 16 -- Mercury 0.026 0.067 0.058 0.14 0.059 0.059 2.3 9.7 0.03 - 0.52 0.121 -- Selenium <1.1 6.5 2.5 <1.1 <0.46 <0.47 78 1,200 <0.1 - 0.8 0.42 -- Silver <0.53 <0 48 <0.42 <0.55 <0.23 <0.23 78 1,200 ND - 5.0 NS -- TCLP Lead (6010D TCLP) (mq/L) Lead ... -- -- -- -- 5 Notes: 1) North Carolina Department of Environmental Quality (DEQ) Preliminary Soil Remediation Goals (PSRGs) (July 2020) 2) Range and mean values of background metals for North Carolina soils taken from Elements in North American Soils by Dragun and Chekiri, 2005 3) Environmental Protection Agency (EPA) Toxicity Characteristic Hazardous Waste Threshold Level (dated October 2009) Soil samples were collected by ECS Southeast, LLP as part of assessments completed in November 2019, August 2020, and October 2020. Soil concentrations are reported in milligrams per kilogram (mg/kg) Compound concentrations are reported to the laboratory method detection limits With the exception of metals, only those compounds detected in at least one sample shown in the table above Laboratory analytical methods are shown in parentheses Bold values exceed the Residential PSRG and regional background levels in the case of metals Underlined values exceed Industrial/Commercial PSRG VOCs = volatile organic compounds; SVOCs = semi -volatile organic compounds; ft bgs= feet below ground surface NE = Not Established; NS= Not Specified; NA = Not Analyzed; -- = Not Applicable; BDL = Below Laboratory Method Detection Limits S:\AAA-Master Projects\SpaceCraft\Bookers Garage\EMP\Tables\Bookers Garage Data Tables.xlsx 1/n/2D21 Background Cd and Ag concentrations were taken from Southeastern and Conterminous US soils Table 1 (Page 1 of 2) Hart &z Hickman, PC Table 1 Summary of Soil Analytical Data Bookers Garage Charlotte, North Carolina H&H Job No. SCF-001 Sample Location Drip Line Samples Industrial/ Regional Background Characteristic Sample ID SS-1 / SS-DUP SS-2 SS-3 SS-4 Residential PSRGs Commercial PSRGs Metals in Soil (z) Hazardous Waste Threshold Level (3) Date 10/9/20 10/9/20 10/9/20 10/9/20 Depth (ft bgs) 0-2 0-1 1-2 0-2 0-2 Range Mean Units mg/kg mg/L VOCs (8260D) NA NA NA NA NA NA -- -- -- -- -- SVOCs (8270E) Acenaphthene NA NA NA NA NA NA 720 9,000 -- -- -- Benzo(a)anth racene NA NA NA NA NA NA 1.1 21 -- -- -- Benzo(a)pyrene NA NA NA NA NA NA 0.11 2.1 -- -- -- Benzo(b)fluoranthene NA NA NA NA NA NA 1.1 21 -- -- -- Benzo(g,h,i)perylene NA NA NA NA NA NA NE NE -- -- -- Chrysene NA NA NA NA NA NA 110 2,100 -- -- -- Fluoranthene NA NA NA NA NA NA 480 6,000 -- -- -- Indeno(1,2,3-cd)pyrene NA NA NA NA NA NA 1.1 21 -- -- -- Pyrene NA NA NA NA NA NA 360 4,500 -- -- -- Metals (6010D/7199/7471B) -- Arsenic NA NA NA NA NA NA 0.68 3.0 1.0 - 18 4.8 -- Barium NA NA NA NA NA NA 3,100 47,000 50 - 1,000 356 -- Cadmium NA NA NA NA NA NA 14 200 1.0 - 10 4.3 -- Chromium (total) NA NA NA NA NA NA NE NE 7.0 - 300 65 -- Hexavalent Chromium NA NA NA NA NA NA 0.31 6.5 NS NS -- Trivalent Chromium NA NA NA NA NA NA 23,000 350,000 NS NS -- Lead 70.7 88.5 2.310 NA 123 150 400 800 ND - 50 16 -- Mercury NA NA NA NA NA NA 2.3 9.7 0.03 - 0.52 0.121 -- Selenium NA NA NA NA NA NA 78 1,200 <0.1 - 0.8 0.42 -- Silver NA NA NA NA NA NA 78 1,200 ND - 5.0 NS -- TCLP Lead (6010D TCLP) (mg/L) Lead <0.025 <0.025 -- -- -- -- 5 Notes: 1) North Carolina Department of Environmental Quality (DEQ) Preliminary Soil Remediation Goals (PSRGs) (July 2020) 2) Range and mean values of background metals for North Carolina soils taken from Elements in North American Soils by Dragun and Chekiri, 2005. Background Cd and Ag concentrations were taken from Southeastern and Conterminous US soils 3) Environmental Protection Agency (EPA) Toxicity Characteristic Hazardous Waste Threshold Level (dated October 2009) Soil samples were collected by ECS Southeast, LLP as part of assessments completed in November 2019, August 2020, and October 2020. Soil concentrations are reported in milligrams per kilogram (mg/kg) Compound concentrations are reported to the laboratory method detection limits With the exception of metals, only those compounds detected in at least one sample shown in the table above Laboratory analytical methods are shown in parentheses Bold values exceed the Residential PSRG and regional background levels in the case of metals Underlined values exceed Industrial/Commercial PSRG VOCs = volatile organic compounds; SVOCs = semi -volatile organic compounds; ft bgs= feet below ground surface NE = Not Established; NS= Not Specified; NA = Not Analyzed; -- = Not Applicable; BDL = Below Laboratory Method Detection Limits Table 1 (Page 2 of 2) S:\AAA-Master Projects\SpaceCraft\Bookers Garage\EMP\Tables\Bookers Garage Data Tables.xlsx 1n/2021 Hart &z Hickman, PC Table 2 Summary of Groundwater Analytical Data Bookers Garage Charlotte, North Carolina H&H Job No. SCF-001 Sample Location Bookers Garage Building Residence 2L (1) Standard Residential GWSLs Non -Residential GWSLs Sample ID TW-1 TW-1 / TW-DUP TW-2 TW-2 Date 11 /8/2019 8/12/2020 11 /8/2019 10/12/2020 Units pg/L VOCs (8260D) ALL BDL ALL BDL ALL BDL ALL BDL ALL BDL -- -- -- SVOCs (8270E) ALL BDL ALL BDL ALL BDL ALL BDL ALL BDL -- -- -- Metals (6010D/7470A) Arsenic NA <4.7 <4.7 NA <10.0 10 -- -- Barium NA 73.1 72.4 NA 88.0 700 -- -- Cadmium NA <0.40 <0.40 NA <1.0 2 -- -- Chromium (total) NA <3.7 <3.7 NA <5.0 10 -- -- Lead NA <4.5 <4.5 NA <5.0 15 -- -- Mercury NA <0.12 <0.12 NA <0.20 1 -- 0.75 Selenium NA <4.7 <4.7 NA <10.0 20 -- -- Silver I NA 1 <2.5 1 <2.5 1 NA 1 <5.0 1 20 1-- -- Notes: 1) North Carolina Department of Environmental Quality (DEQ) 15A North Carolina Administrative Code 02L.0202 Groundwater Quality Standard (2L Standard) (April 2013) 2) DEQ Division of Waste Management (DWM) Vapor Intrusion Groundwater Screening Levels (GWSLs) (February 2018) Groundwater samples were collected by ECS Southeast, LLP as part of assessment activities completed in November 2019 and August 2020. Compound concentrations are reported in micrograms per liter (pg/L) Compound concentrations are reported to the laboratory method detection limits With the exception of metals, only those compounds detected in at least one sample are shown in the table above Laboratory analytical methods are shown in parentheses VOCs = volatile organic compounds; SVOCs = semi -volatile organic compounds NA = Not Analyzed; -- = Not Applicable; BDL = Below Laboratory Method Detection Limits Table 2 (Page 1 of 1) S:\AAA-Master Projects\SpaceCraft\Bookers Garage\EMP\Tables\Bookers Garage Data Tables.xlsx 12/21/2020 Hart & Hickman, PC Table 3 Summary of Soil Gas Analytical Data Bookers Garage Charlotte, North Carolina H&H Job No. SCF-001 Sample Location Northwestern Portion of the Site Central Portion of the Site Southeastern Portion of the Site Residential Non Sample ID SG-1 / SG-DUP SG-1 / SG-DUP SG-2 SG-3 SG-4 SG-5 SG-6 SGSLs (1) -Residential SGSLs (1) Date 8/12/2020 11/5/2020 8/12/2020 11/5/2020 8/12/2020 11/5/2020 8/12/2020 11/5/2020 8/12/2020 11/5/2020 8/12/2020 11/5/2020 Units J9 m3 VOCs (TO-15) Acetone 101 21.4 <11 <11 3,536 99 74.7 69 6,840 54 10,700 42 9,000 110 220,000 2,700,000 Benzene 11.2 10.5 <0.19 <0.19 4.5 6.0 2.6 5.6 12.7 17 22.5 4.9 8.6 7.3 120 1,600 1,3-Butadiene <0.26 <0.21 <0.32 <0.32 <0.19 <0.32 <0.19 <0.32 <0.19 <0.32 <5.0 13 <0.20 <0.32 14 180 2-Butanone (MEK) 18.2 <1.1 <2.0 <2.0 274 14 J 19.7 8.8 J 407 8.3 J 878 7.3 J 522 26 35,000 440,000 Carbon Disulfide 53.1 53.5 <1.6 <1.6 18.2 <1.6 5.2 <1.6 34.9 <1.6 <7.9 <1.6 3.9 <1.6 4,900 61,000 Carbon Tetrachloride <0.38 <0.31 <0.33 <0.33 0.34 J 0.68 J 0.41 J <0.33 <0.29 <0.33 <5.9 <0.33 <0.30 0.50 J 160 2,000 Chlorobenzene <0.39 <0.32 <0.22 <0.22 <0.29 <0.22 <0.29 <0.22 2.4 <0.22 <6.1 <0.22 <0.31 <0.22 350 4,400 Chloroethane <0.34 <0.28 <0.52 <0.52 0.27 J <0.52 <0.25 <0.22 <0.25 <0.52 <5.3 <0.52 <0.26 <0.52 NE NE Chloroform <0.49 <0.41 <0.24 <0.24 0.43 J <0.24 <0.37 0.80 J <0.37 <0.24 <7.8 <0.24 1.3 1.3 41 530 Chloromethane <0.24 <0.20 <0.32 <0.32 1.6 <0.32 0.42 J <0.32 <0.19 <0.32 <3.9 <0.32 <0.19 <0.32 630 7,900 Cyclohexane 14.5 14.5 <0.34 <0.34 12.2 29 7.4 26 23.3 20 31.2 J 22 26.8 33 42,000 530,000 Dichlorodifluoromethane (Freon 12) 1.8 J 1.5 <0.31 <0.31 0.71 <0.31 0.66 J <0.31 <0.57 <0.57 <6.1 <0.31 2.3 30 700 8,800 1,1-Dichloroethene <0.37 <0.30 <0.43 <0.43 0.32 J <0.43 <0.28 <0.43 <0.28 <0.43 <5.8 <0.43 <0.29 <0.43 1,400 180,000 cis- 1,2-dichloroethene <0.41 <0.34 <0.27 <0.27 <0.31 <0.27 <0.31 2.2 2.4 <0.27 <6.5 <0.27 <0.33 <0.27 NE NE trans- 1,2-dichloroethene <0.43 <0.35 <0.30 <0.23 <0.33 <0.23 <0.33 1.4 <0.33 3.5 <6.8 1.2 <0.34 3.4 NE NE Ethanol NA NA 170 170 NA 97 NA 40 NA 110 NA 26.0 NA 47 NE NE Ethyl Acetate <0.43 <0.35 <4.3 <4.3 45.5 <4.3 1.3 J <4.3 <0.33 16 <6.8 <4.3 <0.34 45 490 6,100 Ethylbenzene 3.3 5.3 2.8 2.5 2.0 3.8 <0.35 2.2 1.2 J 1.9 <7.3 2.6 1.3 J 6.2 370 4,900 4-Ethyltoluene <1.2 1.2 J <0.30 <0.30 <0.92 <0.30 <0.92 <0.30 <0.92 <0.30 <19.2 <0.30 <0.96 1.6 NE NE Heptane 18.4 16.8 460 470 <0.34 4.2 <0.34 3.0 <0.34 <0.35 <7.0 11 <0.35 5.7 2,800 35,000 Hexane 28.8 12.5 1,600 1,800 8.3 18 J 3.0 7.0 J 75.0 <1.3 29.4 15 J <0.49 <1.3 4,900 61,000 2-Hexanone 1.7 J 1.7 J <0.46 <0.46 37.1 <0.46 2.5 J <0.46 73.5 <0.46 165 J <0.46 85.0 <0.46 210 2,600 Methylene Chloride 58.5 35.8 <1.6 <1.6 61.8 <1.6 41.0 <1.6 52.5 <1.6 61.1 J <1.6 <2.0 <1.6 4,200 53,000 4-Methyl-2-pentanone (MIBK) <0.54 <0.44 <0.43 <0.43 2.5 J <0.43 0.93 J <0.43 <0.41 <0.43 <8.5 <0.43 <0.42 <0.43 21,000 260,000 Methyl tert butyl ether <0.35 <0.29 <0.29 <0.29 0.41 J <0.29 <0.27 <0.29 <0.27 <0.29 <5.6 <0.29 <0.28 <0.29 3,600 47,000 Naphthalene <3.2 3.8 J 0.82 J <0.59 <2.4 <0.59 <2.4 <0.59 4.9 J <0.59 <50.1 <0.59 <2.5 <0.59 21 260 Propylene 129 <0.21 <1.2 <1.2 25.6 <1.2 13.2 <1.2 94.9 <1.2 811 150 186 <1.2 21,000 260,000 Styrene 0.98 J 1.0 J 1.4 1.5 1.9 2.7 <0.72 2.0 <0.72 1.1 <14.9 2.2 <0.75 4.0 7,000 88,000 Tetrachloroethene <0.73 <0.60 1.4 <0.44 4.3 <0.44 <0.55 <0.44 0.72 J <0.44 <11.6 0.73 J <0.58 0.79 J 280 3,500 Tetrahydrofuran <0.44 <0.36 <1.5 <1.5 2.3 <1.5 1.5 <1.5 <0.33 <1.5 <6.9 <1.5 <0.34 <1.5 NE NE Toluene 103 95.5 38 40 28.5 94 6.5 68 40.7 71 67.4 44 21.0 180 35,000 440,000 Trichloroethene 2.1 1.5 <0.40 <0.40 31.8 11 1.3 46 6.0 <0.40 <7.1 <0.40 0.77 J 1.3 14 180 Trichlorofluoromethane (Freon 11) <0.72 <0.59 <0.85 <0.85 0.88 J 1.7 J 0.64 J 1.3 J <0.55 1.3 J <11.4 1.3 J <0.57 5.0 NE NE 1,1,1,-Trichloroethane <0.34 <0.28 <0.36 <0.36 <0.26 <0.36 <0.26 <0.36 1.6 J <0.36 <5.4 <0.36 <0.27 <0.36 35,000 440,000 1,2,4-Trimethyl benzene 5.1 1.9 J 1.9 <0.22 1.11 3.4 <0.79 <0.22 2.6 <0.22 <16.4 2.5 1.8 J 4.9 420 5,300 1,3,5-Trimethyl benzene <0.77 1.4 J 0.59 J <0.26 <0.58 0.92 J <0.58 0.73 J 1.11 0.33 J <12.1 0.87 J 0.76 J 1.4 420 5,300 m&p-Xylene 7.0 5.1 10 7.6 7.8 9.5 <0.83 7.6 4.5 4.7 <17.2 7.7 4.7 16 700 8,800 o-Xylene 2.5 2.2 5.2 4.5 2.5 4.8 <0.38 3.7 1.9 2.1 <7.8 4.8 1.9 9.2 700 8,800 Notes: 1) North Carolina Department of Environmental Quality (DEQ) Division of Waste Management (DW M) Vapor Intrusion Sub -slab and Exterior Soil Gas Screening Levels (SGSLs) (February 2018) Soil gas samples were collected by ECS Southeast, LLP as part of assessments completed in August 2020 and November 2020. Compound concentrations are reported in micrograms per cubic meter (Ng/m3) Compound concentrations are reported to the laboratory method detection limits Bold concentrations exceed the Residential SGSL Only those compounds detected in at least one sample are shown in the table above Laboratory analytical methods are shown in parentheses. VOCs = volatile organic compounds; NA = Not Analyzed; NE= Not Established J = compound was detected above the laboratory method detection limit, but below the laboratory reporting limit, resulting in a laboratory estimated concentration Table 3 (Page 1 of 1) S:\A -Maser Proje \SPa,eCraf[\Bookers Garage\EMP\Tables\Bookers Garage Data Table,.Al 12/21/2020 Hart & Hickman, PC Figures hart ` hickman SMARTER ENVIRONMENTAL SOLUMNS - i r- tT _ Y ' ...1,'„ IOLK ST "+ r _f,arlMte [hristran oll And Thmloclrll seminary. - O `l`� ✓✓ �� - � .. l`x�••,••� .. -. Hicdilar Kl hil! '� .�• DAL TON AVE -cJF -4---'--•- 'vIII�Hei is -' Scli 11 rocksr one Sc 1,-15 - m rr•-• �VV _ era sr�1 _ R Pti y � CYr� �,P LF k SITE y-- �~ , un" .. Y C pIJN�RY CL01f rrrst YJald 1� Pots Ar_xl- •� !i n••th c•me ,uad+fs ti+��ic$• Y _ _-.-•1 t I CY t I �. Tranty fir., Epls—ll�ai .ti: ' .. Sdi Q 6 H 0 £ ' c . ZA 4 L L• 9"17 CI �; T a Central Plcdrn rdx Cornrnln y Cdl - Ll-ilheth Cemral CanyNfs Traditional Elc- m sch ry r k � ' -J�, Kings �cJl � Q Charlotte oq E 4r 6e Fyn 3� USGS The National Map: National Boundaries Dataset, 3DEP Elevation -)Program, Geographic Names Information.,System, Nationa1&ydrography Dataset, National Land Cover Database, National Structures�Dataset, and National Transportation Dataset; USGS Global Ecosyster4 U.S. Census Bureau TIGER/Line data; USF,S-Road Data; Natural Earth Data; U.S. Department of State Humanitarian Information Unit;an'd, NOAA National Centers for Environmental Information, U.S. Coastal, Relief Model. Data refreshed May, 2020. 0 2,000 4,000 N SCALE IN FEET U.S.G.S. QUADRANGLE MAP CHARLOTTE EAST, NORTH CAROLINA 2013 QUADRANGLE 7.5 MINUTE SERIES (TOPOGRAPHIC) LEGEND SITE PROPERTY BOUNDARY PARCELBOUNDARY PROPOSED BUILDING FOOTPRINT ON GRADE PROPOSED BUILDING ABOVE PARKING GARAGE PROPOSED PARKING DECK SOIL BORING SAMPLE LOCATION (2019) ® SOIL GAS SAMPLE LOCATION (2020) O DRIP LINE SOIL SAMPLE LOCATION (2020) SAMPLE DEPTH (IF APPLICABLE) SAMPLE DATE SAMPLE ID UNITS SS-2 0-1' (10/9/20) mg/kg LEAD 2,310 CONSTITUENT CONCENTRATION NOTES: 1. PROPOSED BUILDING LOCATIONS APPROXIMATED BASED ON CONCEPTUAL REDEVELOPMENT RENDERING. 2. TCE = TRICHLOROETHENE Ng/m3 = MICROGRAMS PER CUBIC METER mg/kg = MILLIGRAM PER KILOGRAM 3. ONLY CONCENTRATIONS ABOVE APPLICABLE STANDARDS SHOWN. 8 APPROXIMATE 0 25 50 SCALE IN FEET Appendix A Redevelopment Plan and Permits hart hickman SMARTER ENVIRONMENTAL SOLUTIONS • • • C C 0 I I I I I I I I I I I I 1 • 2 • 3 LJ F-I F-1 r=�, bu 1�1 0.0 El L 00 77 El El 12d ------- ---L El o EFE OO 0° 0 O 0 00 0 0 0 00000000 0 °000 O 0 0° 0 0 0000 0 ° 0 O° 00000 °OO 0O0° 0 0000000 �0 0 0 0O 00 �Oo o QO oOQ 0° 0 O 0p o 0 O Oo �op0�0 °opo • .. , ■■I� � � III. .-" -uwiluwwuwuuuiuun � � li■ _, 1-11n-i�il�i■l 4 METAL STAIR • 5 PROPOSED AREAS HEATED Level 1 Lobby 344.6 Level 1 Apartments 9507.4 Level 2 Apartments 9896.4 Level 3 Apartments 9896.4 PROPOSED HEATED TOTALS 29644.7 UNHEATED Level 1 Circulation 2491.4 Level 2 Circulation 1628.3 Level 3 Circulation 1628.3 PROPOSED UNHEATED TOTAL 5748.0 0 0 E N N W C: 0 �7C3_ 0 o a 070 7C) U Z .� (3) -0 o � T cts � � o E U -1 - 4 4-5 a.? 0 aD 0 0 _0 U U D_ (D N 0�� co Q) o 0 W o E Q a) U) +� 0 C/) CZ cn U 0 C 7 'E U >. c0 C CZ E C O O � N � U L ZO 4-- O c0 7C) LL LL " 7Dz O 0 Z Qom= -J 0 .L Z z Vi W Z U Z c Q C Y Y LI.I �_ 7 U � V C� o J U Y ❑C 1530 Elizabeth Ave, Suite 200 Charlotte NC 28204 704 405 5980 www.cluckdesign.com Offices: CLT / NYC ��\N LEE KENNF ��� cOLLge�R �E,,ED ARCH ��- �� P�yCH IT ECTG 9�j ��9 PRELIMINARY. NOT FOR CONSTRUCTION DESIGN SUBJECT TO DEVELOPMENT CHANGES ~oRTN CA0.��'\�P ry�RTH CARO�'`�P cy4RLOTTE cygRLOTTE �G C Submitted: 00/00/00 E 15th St & Seigle Ave Charlotte, NC 28205 prepared for: Harrison Tucker CoHab Development • Mark Date Description 01 08/05/2020 Design Signoff Drawings 02 09/16/2020 Design Signoff Revisions • B s 11 FOXTROT ECHO GOLF ❑ DELTA INDIA ❑ CHARLIE JULIET ALPHA BRAVO KILO KEY PLAN LEVEL 1 This Drawing is the property of cluck and is not to be reproduced in whole or in part. It is to be used for the project and site specifically identified herein and is not to be used on any other project. This Drawing is to be returned upon the written request of Cluck. Copyright 2019 Cluck Design Collaborative All Rights Reserved. Project name/#: Project Name / 19_xxx CAD File Name: Project Name.vwx First Floor Floor Plan 1 First Floor Floor Plan Scale: 1 /8" = 1--0-- • 0 4 8 12 16 2 • 3 El 0 ;, A101 • • • C C i 0 0 1 • 2 • 3 • 4 • 5 PROPOSED AREAS HEATED Level 1 Lobby 344.6 Level 1 Apartments 9507.4 Level 2 Apartments 9896.4 Level 3 Apartments 9896.4 PROPOSED HEATED TOTALS 29644.7 UNHEATED Level 1 Circulation 2491.4 Level 2 Circulation 1628.3 Level 3 Circulation 1628.3 PROPOSED UNHEATED TOTAL 5748.0 O N 0 U E N N U) cts � O� 0 O70 4-1 70 —0 cts N U u > U � 0-0 o � L � T cti � � o E U 4-1 - � � U) (D O a� U� co U U U ��� O E� CZ N o 0 W o Q�E Q N U +� u (n CZ Q '- cn U 0 C -0 U E C/) �: O O N 7�5 U L LU Q L a) Z O O CZ 7C) LLL LL LL (1) CZ (1) LL 0 LL " 7DZ c0 Z c� .U)CZ a z 4 Z '� U Zco c rn 01--= Y Y LLI � � 7 U � V C � C) J U N Y • • • rol C i 01 s 1530 Elizabeth Ave, Suite 200 Charlotte NC 28204 704 405 5980 www.cluckdesign.com Offices: CLT / NYC ��\N LEE F(ENNF ��� COLLABpR �EpED ARCH �� �� PRCH IT ECTG 9�j PRELIMINARY. NOT FOR CONSTRUCTION DESIGN SUBJECT TO DEVELOPMENT CHANGES ~oRTN CA0.DP ry�RTH P C,Z"4 TTE �G cy4PLOT.TS �G Submitted: 00/00/00 E 15th St & Seigle Ave Charlotte, NC 28205 prepared for: Harrison Tucker CoHab Development Mark Date Description 01 08/05/2020 Design Signoff Drawings 02 09/16/2020 Design Signoff Revisions FOXTROT NOVEMBER GOLF MIKE INDIA LIMA OSCAR KEY PLAN LEVEL 2 & 3 This Drawing is the property of cluck and is not to be reproduced in whole or in part. It is to be used for the project and site specifically identified herein and is not to be used on any other project. This Drawing is to be returned upon the written request of Cluck. Copyright 2019 Cluck Design Collaborative All Rights Reserved. Project name/#: Project Name / 19_xxx CAD File Name: Project Name.vwx Second Floor Floor Plan 1 Second Floor Floor Plan Scale: 1 /8" = 1--0-- • 0 4 8 12 16 FT 2 K 4 0 ;, A102 • • • C C i 0 0 1 • 2 • 3 • 4 • 5 PROPOSED AREAS HEATED Level 1 Lobby 344.6 Level 1 Apartments 9507.4 Level 2 Apartments 9896.4 Level 3 Apartments 9896.4 PROPOSED HEATED TOTALS 29644.7 UNHEATED Level 1 Circulation 2491.4 Level 2 Circulation 1628.3 Level 3 Circulation 1628.3 PROPOSED UNHEATED TOTAL 5748.0 O N 0 U E N N U) cts � O� 0 O70 4-1 70 —0 cts N U u > U � 0-0 o � L � T cti � � o E U 4-1 - � � U) (D O a� U� co U U U ��� O E� CZ N o 0 W o Q�E Q N U +� u (n CZ Q '- cn U 0 C -0 U E C/) �: O O N 7�5 U L LU Q L a) Z O O CZ 7C) LLL LL LL (1) CZ (1) LL 0 LL " 7DZ c0 Z c� .U)CZ a z 4 Z '� U Zco c rn 01--= Y Y LLI � � 7 U � V N C � C) J U Y • • • rol C i 01 s 1530 Elizabeth Ave, Suite 200 Charlotte NC 28204 704 405 5980 www.cluckdesign.com Offices: CLT / NYC ��\N LEE F(ENNF ��� COLLABpR �EpED ARCH �� �� PRCH IT ECTG 9�j PRELIMINARY. NOT FOR CONSTRUCTION DESIGN SUBJECT TO DEVELOPMENT CHANGES ~oRTN CA0.DP ry�RTH P C,Z"4 TTE �G cy4PLOT.TS �G Submitted: 00/00/00 E 15th St & Seigle Ave Charlotte, NC 28205 prepared for: Harrison Tucker CoHab Development Mark Date Description 01 08/05/2020 Design Signoff Drawings 02 09/16/2020 Design Signoff Revisions FOXTROT NOVEMBER GOLF MIKE INDIA LIMA OSCAR KEY PLAN LEVEL 2 & 3 This Drawing is the property of cluck and is not to be reproduced in whole or in part. It is to be used for the project and site specifically identified herein and is not to be used on any other project. This Drawing is to be returned upon the written request of Cluck. Copyright 2019 Cluck Design Collaborative All Rights Reserved. Project name/#: Project Name / 19_xxx CAD File Name: Project Name.vwx Third Floor Floor Plan 1 Third Floor Floor Plan Scale: 1 /8" = 1--0-- • 0 4 8 12 16 FT 2 K 4 0 ;, A103 • • • M C 0 1 • 2 DESIGN SIGN -OFF NOTE: This Drawing is prepared for the client's final design approval only. Please note that any requested design change made to this drawing after the date noted below may impact project time and schedule and may be subject to additional services that the client will be billed as per the contractual agreement between cluck design collaborative and CoHab. Dated Client's Signature CLUCK INTERNAL SIGN -OFF: Kevin Kennedy Chris Scorsone 15th Street Elevation Scale: 1/8" = V-0" • 0 4 8 12 16 FT 3 • 0 • LDS • • • C 0 1530 Elizabeth Ave, Suite 200 Charlotte NC 28204 704 405 5980 www.cluckdesign.com Offices: CLT / NYC E KFNNcc `G� COLLABpR f-E 1ICy �� �� PRCH IT ECTG 9Tj iT� PRELIMINARY. NOT FOR CONSTRUCTION DESIGN SUBJECT TO DEVELOPMENT CHANGES y0 `aP 40 "" RTH CAftO�. HTH CAROB' cy4&LOTTE �G cygRLOTTE �G Submitted: 00/00/00 E 15th St & Seigle Ave Charlotte, NC 28205 prepared for: Harrison Tucker CoHab Development Mark Date Description 01 08/05/2020 Design Signoff Drawings 02 09/16/2020 Design Signoff Revisions This Drawing is the property of cluck and is not to be reproduced in whole or in part. It is to be used for the project and site specifically identified herein and is not to be used on any other project. This Drawing is to be returned upon the written request of cluck. Copyright 2019 Cluck Design Collaborative All Rights Reserved. Project name/#: Project Name / 19_xxx CAD File Name: Project Name.vwx Exterior Elevations Seigle Ave. Elevation ^' Scale: 1/8" = V-0" 1 0 2 0 4 8 12 16 FT K3 11 0 ;, A201 ct Ck DESIGN COLLABORATIVE 016 •7� i .004 41 1 riear rnevation 0 0 iiiiiiiiiiiiiiiiiip Scale: 1/8" = 1'-0" -� • � • 3 • 4 • 5 ST �S dtHU OLH I U R B A N P DESIGN VICINITY MAP D GENERAL NOTES: 1. ALL WORK AND MATERIALS SHALL CONFORM TO THE LATEST EDITION OF THE CHARLOTTE LAND DEVELOPMENT STANDARDS MANUAL (CLDSM) AND THE LATEST EDITION OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION (NCDOT) STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES UNLESS OTHERWISE SPECIFIED IN THE CHARLOTTE-MECKLENBURG LAND DEVELOPMENT STANDARDS MANUAL. 2. ALL PUBLIC STREETS WITHIN THE DEVELOPMENT WILL BE CONSTRUCTED TO THE CITY OF CHARLOTTE STANDARDS IN ORDER TO BE DEDICATED PUBLIC RIGHT OF WAYS. 3. ALL CURBS SHALL HAVE A 5-0" RADIUS AT THE FACE OF CURB UNLESS OTHERWISE NOTED. ALL R/W SHALL HAVE A 20' RADIUS UNLESS OTHERWISE NOTED. 4. DEVELOPER WILL PROVIDE STREET SIGNS PER CLDSM #50.05A OR #50.05B. SIGNS SHOULD BE LOCATED PER CLDSM #50.06. 5. LAND DEVELOPMENT ENGINEER SHALL BE GIVEN 48 HOURS NOTICE PRIOR TO CONSTRUCTION. 6. SIGHT TRIANGLES SHOWN ARE THE MINIMUM REQUIRED. FURTHER REQUIREMENTS MAY BE MADE BY THE CITY OF CHARLOTTE DEPARTMENT OF TRANSPORTATION (CDOT). 7. NON-STANDARD ITEMS (I.E.: PAVERS, IRRIGATION SYSTEMS, ETC.) IN THE RIGHT OF WAY REQUIRE ENCROACHMENT AGREEMENT WITH THE CHARLOTTE DEPARTMENT OF TRANSPORTATION/NORTH CAROLINA DEPARTMENT OF TRANSPORTATION BEFORE INSTALLATION. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ANY AND ALL ENCROACHMENT AGREEMENTS. FOR CITY OF CHARLOTTE MAINTAINED STREETS, CONTACT CDOT AT (704) 336-3888. 8. ANY BUILDING WITHIN THE 100+1 BUILDING RESTRICTION FLOODLINE IS SUBJECT TO THE RESTRICTIONS OF THE CITY OF CHARLOTTE SUBDIVISION ORDINANCE, SECTION 7.200.8. 9. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3600 P.S.I. AT 28 DAYS AND SHALL COMPLY WITH SECTION 1000 OF THE NCDOT STANDARD SPECIFICATIONS. SIDEWALKS SHALL BE CONSTRUCTED OF NOT LESS THAN 3600 PSI CONCRETE AND SHALL BE FOUR (4)INCHES THICK, CONSTRUCTED ON AN ADEQUATELY GRADED BASE, EXCEPT WHERE A SIDEWALK CROSSES A DRIVEWAY IT SHALL BE SIX (6) INCHES THICK. 10. ALL CONCRETE SHALL BE CURED WITH 100% RESIN BASE, WHITE PIGMENTED CURING COMPOUND WHICH MEETS A.S.T.M. SPECIFICATIONS C-309, TYPE 1, APPLIED AT ONE GALLON TO 400 SF WITHIN 24 HOURS OF PLACEMENT OF CONCRETE. 11. ALL CURB AND GUTTER SHALL BE BACKFILLED WITH SOIL APPROVED BY THE INSPECTOR 48 HOURS AFTER CONSTRUCTION TO PREVENT EROSION. 12. ALL BACKFILL SHALL BE NON -PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATIVE MATTER, WASTE, CONSTRUCTION MATERIAL, OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND THE MATERIAL SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 13. ALL TRENCHES IN THE STREET RIGHT OF WAY SHALL BE BACKFILLED WITH SUITABLE MATERIAL IMMEDIATELY AFTER THE PIPE IS LAID. 14. ALL SUBGRADE FOR ROADS SHALL BE COMPACTED TO 100% OF THE MAXIMUM DENSITY OBTAINABLE WITH THE STANDARD PROCTER TEST. 15. ALL TESTS SHALL BE PERFORMED BY THE DEVELOPER AT NO COST TO THE CITY. 16. CONTRACTOR SHALL MAINTAIN TWO WAY TRAFFIC AT ALL TIMES WHEN WORKING WITHIN EXISTING STREETS. THE CONTRACTOR SHALL PLACE AND MAINTAIN SIGNS, DANGER LIGHTS, BARRICADES, AND FURNISH WATCHMEN OR FLAGMEN TO DIRECT TRAFFIC IN ACCORDANCE WITH THE WORK AREA TRAFFIC CONTROL HANDBOOK (W.A.T.C.H.). 17. SUBGRADE FOR SIDEWALKS SHALL BE COMPACTED TO 95% OF THE MAXIMUM DENSITY OBTAINABLE WITH THE STANDARD PROCTER TEST. THE SURFACE OF THE SIDEWALK SHALL BE STEEL TROWEL AND LIGHT BROOM FINISHED AND CURED WITH AN ACCEPTABLE CURING COMPOUND. TOOLED JOINTS SHALL BE PROVIDED AT AN INTERVAL NOT LESS THAN FIVE (5) FEET AND EXPANSION JOINTS AT INTERVALS NOT MORE THAN 45 FEET. THE SIDEWALK SHALL HAVE A LATERAL SLOPE OF 1/4" PER FOOT. 18. THE ELEVATION OF THE SIDEWALK SHALL BE RELATED TO THE ELEVATION OF THE CROWN OF THE ADJACENT ROADWAY. THE SIDEWALK SHALL BE NO LESS THAN SIX (6) INCHES OR MORE THAN 18 INCHES ABOVE THE ROADWAY CROWN, EXCEPT THAT THE CROSSWALK ELEVATIONS SHALL BE PROPERLY RELATED TO THE EXISTING OR PROPOSED ROADWAY CURB. 19. IN ROLLING AND HILLY TERRAINS, SWEEPING OF THE STONE BASE AND/OR APPLICATION OF A TACK COAT MAY BE REQUIRED NEAR INTERSECTIONS. THESE REQUIREMENTS WILL BE ESTABLISHED BY THE INSPECTOR BASED ON FIELD CONDITIONS. 20. UTILITY INSTALLATIONS MAY ONLY CROSS BUFFER AREAS AT INTERIOR ANGLES MEASURED AT PROPERTY LINES WHICH ARE NOT LESS THAN 75 DEGREES AND, TO THE EXTENT POSSIBLE, PATHS CLEARED FOR SUCH UTILITY LINES SHALL BE REPLANTED WITH PLANT MATERIALS FROM THE ORDINANCES APPROVED PLANT LIST. 21. NO BUILDINGS, PARKING SPACES OR MANEUVERING AREAS MAY BE LOCATED WITHIN ANY BUFFER AREAS. 22. THE DEVELOPER SHALL MAKE A DILIGENT EFFORT TO PRESERVE AREAS OF REQUIRED BUFFERS WHERE SIGNIFICANT VEGETATION EXISTS. THESE AREAS SHALL REMAIN UNDISTURBED EXCEPT TO THE EXTENT NECESSARY TO ACCOMMODATE THE ABOVE ITEMS OF THIS SECTION. 23. UNDER DRAINAGE SHALL BE PROVIDED AS DIRECTED BY GEO-TECHNICAL ENGINEER. DETERMINATION SHALL BE MADE IN THE FIELD. DRAINS TO BE INSTALLED PER CMLD STD #30.05. 24. SUBSURFACE DRAINAGE FACILITIES MAY BE REQUIRED IN THE STREET RIGHT-OF-WAY IF DEEMED NECESSARY BY THE INSPECTOR. 25. "AS -BUILT" DRAWINGS AND PLANS OF THE STORM DRAINAGE SYSTEM, INCLUDING DESIGNED DITCHES, MUST BE SUBMITTED PRIOR TO SUBDIVISION FINAL INSPECTION TO THE CITY/COUNTY ENGINEERING DEPARTMENT IN ACCORDANCE WITH THE CITY/COUNTY SUBDIVISION ORDINANCE. 26. CURB AND GUTTER ON THE PLANS MAY BE ADJUSTED BASED ON FIELD STAKING BY CITY ENGINEERING. ASSOCIATED STORM DRAINAGE MAY ALSO REQUIRE MODIFICATION BASED UPON FIELD CONDITIONS. 27. THE PURPOSE OF THE STORM DRAINAGE EASEMENT (SIDE) IS TO PROVIDE STORM WATER CONVEYANCE AND ANY STRUCTURES AND/OR OBSTRUCTION TO STORM WATER FLOW IS PROHIBITED. 28. HIGH -DENSITY POLYETHYLENE (HDPE) STORM DRAINAGE PIPE INSTALLED WITHIN EXISTING OR PROPOSED PUBLIC STREET RIGHT-OF-WAY MUST BE APPROVED BY THE CITY'S INSPECTOR PRIOR TO ANY BACKFILL BEING PLACED. BACKFILL MATERIAL MUST BE APPROVED BY THE CITY INSPECTOR PRIOR TO PLACEMENT OF THE MATERIAL WITHIN THE PUBLIC STREET RIGHT-OF-WAY. 29. ALL ROAD IMPROVEMENTS ON SEIGLE AVE AND E 15TH ST ARE TO BE COORDINATED WITH THE CITY OF CHARLOTTE ENGINEERING DEPARTMENT PRIOR TO CONSTRUCTION. 30. CONTACT THE UTILITY COMPANY TO RELOCATE ANY EXISTING UTILITY POLES. ALL EXISTING FACILITIES WHICH CONFLICT WITH THE IMPROVEMENTS UNDER THE SCOPE OF THIS PROJECT MUST BE RELOCATED AT THE EXPENSE OF THE APPLICANT. 31. ALL DEVELOPMENT CREATING A TOTAL 20,000 SQUARE FEET OF IMPERVIOUS AREA SINCE SEPTEMBER 1978 WILL REQUIRE STORM DRAINAGE DETENTION. 32. NON-STANDARD ITEMS (IE: PAVERS, IRRIGATION SYSTEMS, ETC.) IN THE RIGHT-OF-WAY REQUIRE A RIGHT-OF-WAY ENCROACHMENT AGREEMENT WITH THE CHARLOTTE DEPARTMENT OF TRANSPORTATION/NORTH CAROLINA DEPARTMENT OF TRANSPORTATION BEFORE INSTALLATION. FOR CITY OF CHARLOTTE MAINTAINED STREETS, CONTACT CDOT AT 704-336-3888. 33. ANY WORK WITHIN THE CITY'S R/W THAT REQUIRES CLOSURE OF A SIDEWALK OR TRAVEL LANE MUST BE APPROVED BY CDOT AND WILL REQUIRE A R/W USE PERMIT OR R/W LEASE DEPENDING UPON THE PROPOSED DURATION OF CLOSURE. THESE APPROVALS ARE IN ADDITION TO SITE APPROVALS AND SHOULD BE COORDINATED WITH CDOT PRIOR TO CONSTRUCTION. CONTRACTOR SHALL CONTACT CDOT AT (704) 432-1562 AT LEAST 5 BUSINESS DAYS PRIOR TO BEGINNING WORK FOR IMPACTS LESS THAN 30 DAYS. CONTRACTOR SHALL CONTACT CDOT AT (704) 336-8348 AS SOON AS POSSIBLE FOR IMPACTS GREATER THAN 30 DAYS. EVERY EFFORT SHALL BE MADE TO CONSTRUCT IMPROVEMENTS WITH MINIMAL IMPACT TO DRIVERS AND PEDESTRIANS. 34. THE DEVELOPER SHALL CONTACT THE CHARLOTTE DEPARTMENT OF TRANSPORTATION (GUS JORDI, 704-336-7086) TO IDENTIFY ANY CONFLICTS WITH TRAFFIC SIGNALIZATION EQUIPMENT. 60- 90 DAYS WILL BE REQUIRED TO COORDINATE RELOCATION. DEVELOPER SHALL BE RESPONSIBLE FOR ALL RELATED RELOCATION COST AND/OR ANY REPAIR COST CAUSED BY THE CONTRACTOR/DEVELOPER. 35. DEVELOPER TO CONTACT CDOT (ANTHONY MENDEZ: 704-336-4971) DURING SITE PLAN PREPARATION TO DISCUSS STREET LIGHTING REQUIREMENTS, IF ANY, FOR THIS PROJECT. COORDINATE WITH DUKE ENERGY AND CDOT AS NECESSARY TO DETERMINE LIGHTING LEVELS, LIGHTING LAYOUT AND REQUIREMENTS FOR INSTALLATION. 36. PRIVATE DEVELOPMENT UTILITY RELOCATION COORDINATION - FOR UTILITY COORDINATION RELATED TO BOTH EXISTING UTILITY RELOCATION NEEDS AND PROPOSED NEW UTILITY INSTALLATIONS, PLEASE CONTACT RALPH TRUITT, CDOT ROW UTILITY COORDINATOR AT 704-336-4248 OR RTRU ITT@CHARLOTTENC. GOV. 7 1121 Seigle Ave, Charlotte, NC 28205 i P I D: 081-099-13, 081-099-14, 081-099-21 SEIGLE AVENUE 50' PUBLIC R/W CDOT MAINTAINED 25 MPH SPEED LIMIT �C-) m 0 C;1 moo- , 2 -0 Cn nc -� 0> T1 n �m m o m I I I I II I II I II I II I II I II �o CONTACT INFORMATION OWNER: COHAB LLC CONTACT: HARRISON TUCKER ADDRESS: 1918 BEVERLY DRIVE CHARLOTTE, NC 28207 PHONE: 704-995-2254 EMAIL: HTUCKER@COHABDEV.COM CIVIL ENGINEER & LANDSCAPE ARCHITECT: URBAN DESIGN PARTNERS PLLC CONTACT: BRIAN D. SMITH, PE ADDRESS: 1318-E6 CENTRAL AVENUE CHARLOTTE, NC 28205 PHONE: 704-334-3303 FAX:704-334-3305 EMAIL: BRIAN@URBANDESIGNPARTNERS.COM ARCHITECT: CLUCK DESIGN COLLABORATIVE CONTACT: SWIKAR GHADIA ADDRESS: 1530 ELIZABETH AVE #200 CHARLOTTE, NC 28204 PHONE: 704-405-5980 EMAIL: SWIKAR@CLUCKDESIGN.COM PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 F 704.334.3305 urbandesignpartners.com nc firm no: P-0418 sc coa no: C-03044 000000000000000 000aoo� ,�N pQ°ca°Ro°°oo0000 ` °�aosc�° o- to ° W 1 06 -tr of o ° o� =O o � 09/30/2020 L U U 0 j N J o °N° J O a� z W L p 00 S r= U = 0-)U T LO Sheet List Table T Sheet Number Sheet Title `o O C-1.0 Cover Sheet N C-1.1 Submittal Table z C-2.0 Existing Conditions C-3.0 Site Plan o C-3.1 Open Space Plan CZ C-4.0 Grading & Storm Drainage Plan _C: U C-6.0 Utility Plan � > Q C-7.0 Erosion Control Ph 1 & Demolition Plan > C-7.1 Erosion Control Ph 2 C/) OT C-8.0 Site Specifications & Details (� T U T C-8.1 Site Specifications & Details C-8.2 Site Specifications & Details C-8.3 Site Specifications & Details C-8.4 Erosion Control Details LS-1.0 Landscape Plan LS-2.0 Landscape Details A1.1 Rezoning Plan Z O A201 Exterior Elevations A202 Exterior Elevations w °C m ui Q O Z Project No: 19-133 Date: 09.30.2020 Designed by: UDP 01�A� Drawn By: UDP Sheet No: GRAPHIC SCALE 20 0 10 20 40 1 INCH = 20 FEET ■ 37. A JOINT USE MANHOLE (MEET -ME MANHOLE) IS TO BE PROVIDED BY THE DEVELOPER TO ACCOMMODATE ALL UTILITY TELECOM SERVICE PROVIDERS. THE JOINT USE MANHOLE SHALL BE LOCATED ON PRIVATE PROPERTY OUTSIDE OF THE CITY RIGHT-OF-WAY. SHEET INDEX 100% CD's TO LAND DEVELOPMENT SUBMITTAL 09/30/2020: C-1.0 COVER SHEET O C-1.1 SUBMITTAL TABLE O U R B A N C-2.0 EXISTING CONDITIONS O C-3.0 SITE PLAN O D E S I G N C-3.1 OPEN SPACE PLAN O C-4.0 GRADING & STORM DRAINAGE PLAN O PARTNERS C-6.0 UTILITY PLAN O 1318-e6 central ave. P 704.334.3303 C-7.0 EROSION CONTROL PH 1 & DEMOLITION PLAN O charlotte, nc F 704.334.3305 urbandesignppannertners.com C-7.1 EROSION CONTROL PLAN PH 2 O nc firm no: P-0418 sc coa no: C-03043044 C-8.0 SITE SPECIFICATIONS & DETAILS O C-8.1 SITE SPECIFICATIONS & DETAILS O C-8.2 SITE SPECIFICATIONS & DETAILS O C-8.3 SITE SPECIFICATIONS & DETAILS O FOR C-8.4 EROSION CONTROL DETAILS O REFERENCE LS-1.0 LANDSCAPE PLAN O LS-2.0 LANDSCAPE DETAILS O ONLY --------------------------------------- --------------------------------------- A1.1 REZONING PLAN O A201 EXTERIOR ELEVATIONS O A202 EXTERIOR ELEVATIONS O N U U 0 j N —J o °N° -J z O a) c� a L 4-1 p 00 S r0 U = rn U T z _0 U) W 1 Project No: 19-133 Date: 09.30.2020 Designed by: UDP Drawn By: UDP Sheet No: GENERAL NOTES: 1. CIRCLES ANNOTATE REVISED SHEETS ■ II I I I III I � I III I c I IIII I ,��T 684 _ I ll� 1 � I'�L, ► I jl I I I I II I ► I I I THOMAS ELI BOONE AND DANELLE KINZENBAW BOONE 1 ANNMILLAR PID JJ: 08109915 I I I I BLOCK 4 SECTION 2 \ \\I 1 PID #:A 08109909 MB 157-43 BLOCK 4 SECTION 2 ZONED: R-5MB m I I ZONED: 1 R 5 43 USE: SINGLE FAMILY \ RESIDENTIAL rn ° f I /� I I RIM=686.3' USE: SINGLE FAMILY INVERT 1N=680.3' 1 RESIDENTIAL / ) 1 / & I I 1 I I INVERT OUT=680.2' IRE - - / �� _ / N43 33' 2=E-150.27' \ \ \ l lRF T �- / \ - \ L- s I� i' EXISTING CONDITIONS NOTES: 678 \ 1 11 I \ GRATE=686.3' 11 SE 24"-30" IN=6 9.9' EXISTING INFORMATION ON THIS PLAN WAS PROVIDED BY: - - 9- t - g- 6 NE 24"-30" 1N=679.8' e - 9- - - - 9- A.G. ZOUTEWELLE SURVEYORS 679 - \ \ \ \ / ASPHALT DRIVE I \ \ 24"-30" our=67$.6' 1418 EAST FIFTH STREET IICH (7 4)3729444 L-28204 29.3' o 20 ERIN T THOMAS AND / N \ �\ I SCOTT BOULET PID 08109910 / l l �/ / O' m / 24 1-STORY FRAME COVERED I III I I� II BLOCK 4 SECTION 2 //Q MB 151-43 1 � o RESIDENCE PORCH 0 \ ZONED: R-5 V / / p / / / / \ NO. 820 I Ip \ USE: SINGLE FAMILY RESIDENTIAL PAVEMENT AR A /VN I ® I 1 I I I I 1 / \ II FFE= 688.8' 29.3' CONC. 1z-N43-3'21 E - 7a09' lRS I\�� 22 - - I ----N-43-3'21 E- 75.09' - - -- - I IPF r/T O O I - --- ohe---- ohile -- - -III tI1l he II1 / /D ohe -ohe- I 15" `° oheoh�- - - ohe 39' 631 - -- ohe - - -- ohe -oheo co/ /1111 MILDRED M DIAGO AND ELLORENZO DIAGO PlD J.- 08109911 BLOCK 4 SECTION 2 MB 151-43 26 o / /a USE: ZSINGLE FAMILY I I / FFE=683.5' \ / I \1 w --L mRESIDENTIAL 4c, O 11 II II I II 1 cn I I II GRA7E=679.1' I o 24" 1N=675.1' /aJo / /a� I / ASPHALT DRIVE / / (/) C I I I 1 24" OUT=675.0' m / s` / / / / a \ \\ I I / -0 D W 2 mz�cn 1-STORY N o \ / BLOCK CHURCH a Ia NO. 1113 I /aa // 16" \ I / r z \ m II II / m m I\03 a o 1 ao° 23' \ o � / a I I I I m 11 II GRATE=688.8' r/ \ / 5 I ELLIP. 1N=683.2' / \ o 0 18"double N 14.4' I I I I ELLIP. OUT=683.1' 74.6' \ \� � z \ FFE=683.5' I A 8.8' \ X 6g3 5.6' / \ I T \ \ \ \\ \ \I LlMIS OF TEMPORARY 42' -'TIONEASEMENT /a 683 DE 23928-16 FFE=686.9/ CONC. R-5 ZONING I I N Ii I II II I I �I�III II I \ \� lRF \ l\ 8.1 I \ LOT 2 B-1 ZONING \ i \ \ I LOT 1 m I i I II I I III Z vvv P CH /� I I I II IIIw + II \\ o 0 / I I I I I I I IIII 1 0 2 1-STORY FRAME 1-STORY FRAME I I I a \ \ --- m _/1 RESIDENCE I I RESIDENCE I I I l a 1 684 NO. 1115 I OSSIBLEE GAS PNO. 1121 v COVERED I I I \ m0 I l�INE THIS AREA PORCH II I I I III W I I �1 F � II I I I T\\\\ FFE=687.3' m\ I I I T I I I I I 1 5' I\ Z I I I I I 'i'I I 28.4' I l \ 27.9' FFE-689.1' \ I I I I I IIII m I I \ m1 ALL TIME FACTORS, INC N_ m \ \ 23 I l \ COVERED I PID Jr 08109912 o v m 686 - _ \ \ \ COVERED I / \ PORCH o I II BLOCK 4 SECTION 2 _ \ PORCH I I I I I MB 151-43 mm I / l MlT OF TEMPORARY CONSTRUCTION USE - ZONED: ED: 8-1 o v o o II CONCRETE DRIVE \ \ \ \ \ \ / / C \ / / EASEMENT DB 23553-310 ° o o (HATCAN H T SIDEWALK EASEMENT I P I DB 7336t 129 I �4 I I III \ \ / CONC. 68� - - / I I 1 I I II GRATE=688.6' ! - - - w� STEPS CONCRETE 4 I I I, I ELLIP. IN=684.1' DRIVE i I I I \f I I III ELLIP. OUT=683.8' SIDEWALK & UTILITY EASEMENT (DB 23928-167) - - _ 669 CONC. I I I 1 I III I \\ F2 - o WALK I N.C. GRID COORDINATES L N: 543, 350.07' \ I III o E. 1,456,12765 ' \ \ \ - \ I I I I I Z. 688.81 ' -_'(DE ALK & UTILITY EASEMENT (D 23553-510) IRS __ / 1 _ S43'40'46"W-75.00 D IRS • S43\40'46"W-75.00' - lR o I \ m R1M=689.6' \ 15" 1N=684.3' / 18" 1N=681.3' \ CONCRETE ELLIP. 1N=684.4' 24" OUT678.4' SIDEWALK 77w: N 15" 1N=684.4' ELLIP. OUT=684.3' F eER-oP nc ON m - O ---ohe----ohe- -ohe----ohe- ---oht \\\ O I \ CURB CUT _I - -\ - \ -- BACOFCURB CURB CUT ---- - --____--- --------------- --w £I R.C.P.K - - - - - - - - --------- - 15" - ---- -------- ------- --- - ------------------- - - - - - - - - - - - w----w--6' -----w----w----w ---w �--II _ I\- 15"\ R.C-.P.w----w---w----w--o O\-W � _--w----w----w---- -- -- / lw----w---w----w----w- w----w---- w--APPRXIMATE__ _ \ \ \ LOCATION OF GRATE=688.8' I� - 6 I I O� - SS - - SS� - - Ss -ems \ I \ EXISTING ELM 18" 1N=682.0' - - - - APPROXIMATE Z \ I I - - LOCATION OF GRATE=688.2" 18" OUT=682.2' GRATE=688.6' RIM=688.9" y 'c I A - EXISTING ELM 15" OUT=685.1' SE INVERT 1N=683.3' I I ++ l \ 69 I \ n 1 I NE INVERT 1N=682.6' I I 15" OUT=685.4' 7 I I INVERT OUT=682.4'co I l a 1 I I SEIGLE AVENUE I I 50' PUBLIC R/W I I v /�1 1 CDOT MAINTAINED 1�1 CDOT MAINTAINEDCI I1 BEFORE YOU DIGI CALL 811 OR 1-800-632-4949 N.C. ONE -CALL CENTER IT'S THE LAWI 71�j GRAPHIC SCALE 10 0 5 10 20 1 INCH = 10 FEET U R B A N DESIGN PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 F 704.334.3305 u rbandesign partners. com nc firm no: P-0418 sc coa no: C-03044 FOR REFERENCE ONLY ^L W U U 0 j N J o °N° J z a)\V '0'^ vJ Q m o O Cz 00 T U = �0 LO r U)U-) O O� N }+ Z J C 0 O � U) V / C v5 Cl) T_ W T T Project No: 19-133 Date: 09.30.2020 Designed by: UDP Drawn By: UDP Sheet No: C-200 ANNA MILLAR PID # 08109909 BLOCK 4 SECTION 2 MB 151-43 ZONED: R-5 USE: SINGLE FAMILY RESIDENTIAL - J - - ERIN T THOMAS AND SCOTT BOULET PID #• 08109910 BLOCK 4 SECTION 2 MB 151-43 ZONED: R-5 USE. SINGLE FAMILY RESIDENTIAL / I I I 10' BUFFER ZONE FROM TOP OF BANK I I / EXTERIOR CONCRETE EGRESS RAMP WITH HANDRAILS (REF. ARCH) / a / a 3.7' a MILDRED M DIAGO%ND_ _ ELLORENZO DIAGO PID # 08109911 BLOCK 4 SECTION 2 MB 151-43 ZONED: R-5 41 USE: SINGLE FAMILY RESIDENTIAL Z ❑ 10.Oj o o � I, LIMITS OF hMF9RARY CONSTRUCTIO EASEMENT DB 239 - 67 R-5 ZONING / B-1 ZONING I EXIST. WALL \ TO REMAIN \\ z \ ALLTIME FACTORS, INC ti PID #- 08709912 Z"'_ 30' PCCO BUFFER PROP. PLATFORM RAMP (REF. ARCH) LIMITS OF TEMPORARY CONSTRUCTION EASEMENT PROP. 6" STAIRS WITH HANDRAILS (REF. ARCH) BLOCK 4 SECTION 2 MB 751-43 ZONED. B-1 USE: COMMERCIAL o � o I PROP. BACKFLOW PREVENTER LOCATION I II (REF. C-6.0) II \ SIDEWALK & UTILITY EASEMENT I I (DB 23928-167) 4.2' -_--- - - - 5 - - - 0 S43°40'46 "W-75.00' 16' SETBACK FROM BACK OF CURB EXIST. CONCRETE SIDEWALK TO REMAIN 26.2' THOMAS ELI BOONE AND DANELLE KINZENBAW BOONE PID # 08109915 BLOCK 4 SECTION 2 MB 151-43 ZONED: R-5 USE: SINGLE FAMILY RESIDENTIAL N43'33'22"E-150.27' - - - PROP. PLATFORM RAMP (REF. ARCH) II Illlrlllll I I I I I FF I I PROP. BUILDING 4 FLOORS (f48,371 SF) I I I LE I I I I I a 4 a EGRESS STAIR 20' REAR YARD (REF. ARCH) O �i PROP. REMOVABLE STAIRS WITH HANDRAILS (REF. ARCH) PROP. 16 SETBACK FROM BACK OF CURB PROP. 2' SIDEWALK UTILITY EASEMENT PROP. PERPENDICULAR RAMP, TYP. (CLDSM 10.31A) PROP. REMOVABLE STAIRS WITH HANDRAILS (REF. ARCH) II � II I II I II I II _T I a � I I PROP. SIDEWALK I ° TRANSITION 144'R(CLDSM: 10.23) Ia PROP. STANDARD CURB & GUTTER MATCH EXISTING i (CLDSM: 10.17A) I/ ti a m 50' III o rn 4 I 1 II I I I 25.0' I� 7' I I I PROP. ACCESSIBLE ON -STREET PARALLEL PARKING & SIGN rI (CLDSM:50.09D & 50.10A) II I I Q a�g8 � m 4 I 8.5' � O O --� 7. 0' 2 -I Cn 0 > 00 = a 3 rmznC/) M���7 I Imo- �zm m m I I I II I I I I I I II J PROP. ON -STREET 60' PROP. RIGHT-OF-WAY i I �a PARKING PARALLEL I (CLDSM: ) I I EX. RIGHT-OF-WAY I - i PROP. 2' SIDEWALK UTILITY I 1 as EASEMENT I I� o ° a p5C PROP. 8' CONCRETE SIDEWALK 4' MIN. 8' LANDSCAPE STRIP (CLDSM: 10.22) I (WIDTH VARIES) I 8.0' 8. 0' 7'R PROP. STANDARD CURB & GUTTER MATCH EXISTING (CLDSM: 10.17A) IPERMANENT SIDEWALK EASEMENT (HATCHED 733129 AREA) DBI I I PROP. FDC PROP. SHORT-TERM / BIKE RACK (CLDSM: 50.20) a a \ a a a o - - - i o a --- SIDEWALK & U LITY EASEMENT (DB 3553 a a - "7: r` LI a - � - -- - - - - PROP. ELEVATED s43.40'4667W 75.00' O as CONCRETE STOOP a a a (REF. ARCH) Z ° 00 a Z 0 00 _ 1'R1 ' R'*_� EXIST. DROP CURB PROP. DROP CURBP PROP. STANDARD CURB & GUTTER PROP. 8' CONCRETE EXIST. LIGHT MATCH EXISTING SIDEWALK POLE TO REMAIN EXIST. COMMERCIAL DROP CURB EXIST. CURB & (CLDSM: 10.17A) (CLDSM: 10.22) TYPE II DRIVEWAY TO REMAIN GUTTER TO REMAIN PROP. WATER MIN. 8' LANDSCAPE EXIST. FIRE HYDRANT (CLDSM: 10.256) METER LOCATION STRIP TO REMAIN (REF. C-6.0) SEIGLE AVENUE 50' PUBLIC R/W CDOT MAINTAINED 25 MPH SPEED LIMIT I II N I 10'X10' II TRIAN SIGHT TRIANGLE \ I II 1'R I� N PROP. DIRECTIONAL CURB RAMP (CLDSM: 10.40A) PROP. 1.5' MILL & OVERLAY (TYP.) DEVELOPMENT SUMMARY TAX PARCEL ID #: 081-099-13, 081-099-14, 081-099-21 TOTAL SITE AREA: 0.52 AC (22,553 SF) EXISTING ZONING: MUDD(CD) REZONING NUMBER: 2019-008 PROPOSED FAR: 1.95 DWELLINGS UNITS PER ACRE: 55 DUA SETBACKS: FRONT: SEIGLE AVE: 16' FROM B.O.C. E 15TH ST: 16' FROM B.O.C. SIDE: 0' & 10' BLDG SEPARATION REAR: 20' (PER RZ) MAX. BUILDING HEIGHT: 44' (PER RZ) PROPOSED BUILDING HEIGHT: 44' (4 FLOORS) (REF ARCH SHEETS A201 & A202 FOR MORE INFORMATION) PROPOSED USE: MULTI -FAMILY DWELLING UNITS FOR RENT (28 UNITS: (5) 1 BDRM, (15) 2 BDRM, (8) 3 BDRM) BUILDING GFA: 48,371 SF VEHICULAR PARKING: REQUIRED: 51 SPACES 2 STALLS/ 3 BDRM UNIT = 16 SPACES 1 STALL + 1 STACKER/ 2 BDRM UNIT = 30 SPACES 1 STALL/ 1 BDRM UNIT = 5 SPACES PROPOSED: 51 SPACES (48 UNDERGROUND & 3 ON -STREET) BICYCLE PARKING: REQUIRED: LONG-TERM: N/A SHORT-TERM: 2 SPACES (1/20 UNITS) PROPOSED LONG-TERM: N/A SHORT-TERM: 2 SPACES (1 RACK) TREE SAVE: REQUIRED: 3,383 SF PRESERVED (15%) OR 4,382 SF REPLANTED (19%) PROPOSED: 4,577 SF SEE SHEET C-3.1 FOR LOCATION AND CALCULATIONS OPEN SPACE: REQUIRED: 150 SF (22,533 SF/150 SF PER REZONING) PROPOSED: 1,002 SF SEE SHEET C-3.1 FOR LOCATION AND CALCULATIONS NATURAL AREA: REQUIRED: N/A DUMPSTER & RECYCLE: REQUIRED: (1) 8 CY DUMPSTER (1/30 UNITS) (1) RECYCLING STATION (144 SF) PROPOSED: (1) 8 CY DUMPSTER & (1) 144 SF RECYCLING STATION (REF. ARCH) NOTES: U R B A N DESIGN PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 F 704.334.3305 urbandesig n partners. com nc firm no: P-0418 sc coa no: C-03044 000000000000000 0000� ,�N °CAIQO �0000 :`gym ty{^/�oo 00 OO�n CI•�Op000000° OOpO A .1 �w000000�� 09/30/2020 i U U 0 j N J o � J 0 a) �V '0'^ LO o O cz co T LO r Ln O N 00 N Z O O i U 6 > Q n� li W W Cl) r}n+ V J N z O L w 0I ui Q 0 z Project No: 19-133 Date: 09.30.2020 Ur!,Ol4o: Designed by: UDP �Drawn By: UDP a Sheet No: BEFORE YOU DIGI GRAPHIC SCALE CALL 811 OR 1-800-632-4949 10 0 5 10 20 N.C. ONE -CALL CENTER IT'S THE LAW1 1 INCH = 10 FEET C-300 1. BOUNDARY AND TOPOGRAPHIC INFORMATION PROVIDED BY: A.G. ZOUTEWELLE 1418 EAST FIFTH STREET CHARLOTTE, NC 28204 (704) 372-9444 2. SEE ARCHITECTURAL PLANS FOR BUILDING FOOTPRINT DIMENSIONS PREPARED BY: CLUCK DESIGN COLLABORATIVE 1530 ELIZABETH AVE, SUITE 200 CHARLOTTE, NC 28204 (704) 405-5980 3. CONTACT THE UTILITY COMPANY TO RELOCATE ANY EXISTING UTILITY POLES. ALL EXISTING FACILITIES WHICH CONFLICT WITH THE IMPROVEMENTS UNDER THE SCOPE OF THIS PROJECT MUST BE RELOCATED AT THE EXPENSE OF THE APPLICANT. 4. ALL DEVELOPMENT CREATING A TOTAL 20,000 SQUARE FEET OF IMPERVIOUS AREA SINCE SEPTEMBER 1978 WILL REQUIRE STORM DRAINAGE DETENTION. 5. TREES WITHIN THE STREET RIGHT-OF-WAY ARE PROTECTED BY LAW. PERMIT REQUIRED FOR REMOVAL BY CITY OF CHARLOTTE LANDSCAPE MANAGEMENT AT 704-336-4262. ALL TREES OVER 8-INCHES IN DIAMETER (4.5-FT ABOVE GROUND) IN SETBACK AREA ARE PROTECTED BY LAW. PERMIT REQUIRED FOR REMOVAL BY CITY ENGINEERING AT 704-336-6692. 6. TRASH SERVICE FOR THE SITE WILL BE CONTRACTED THROUGH A PRIVATE COLLECTION COMPANY. COORDINATION FOR SERVICE IS THE RESPONSIBILITY OF THE APPLICANT. 7. DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. CURB RADII SHALL MEASURE 5' AT FACE OF CURB UNLESS OTHERWISE NOTED. 8. LOCATIONS OF SITE LIGHTING ARE APPROXIMATE. THE FINAL NUMBER AND LOCATIONS OF LIGHTS SHALL BE DETERMINED BY THE OWNER AND DUKE ENERGY. 9. ALL UTILITIES WILL BE UNDERGROUND. ANNA MILLAR PID # 08109909 BLOCK 4 SECTION MB 151-43 ZONED: R-5 USE: SINGLE FAMIL ) RESIDENTIAL DENUDED LIMITS I ERIN T THOMAS AND I SCOTT BOULET PID #• 08109910 m BLOCK 4 SECTION 2 MB 151-43 ZONED: R-5 USE. SINGLE FAMILY RESIDENTIAL MILDRED M D1AG0__AND_ _ ELLORENZO DIAGO — — 2 PID # 08109911 BLOCK 4 SECTION 2 MB 151-43 n ZONED: R-5 USE: SINGLE FAMILY RESIDENTIAL 2 m 2 m R-5 ZONING B-1 ZONING ALLTIME FACTORS, INC PID # 08109912 BLOCK 4 SECTION 2 MB 151-43 ZONED: B-1 USE: COMMERCIAL SIDEWALK & UTILITY EAS (DB 2392� DDCCCD\/Cr1 00!'10 TDCC CA\/C ADCA D. ------ - - - - -- ■■■.■■.■■.■■.■■..- SEIGLE AVENUE 50' PUBLIC R/W CDOT MAINTAINED 25 MPH SPEED LIMIT F ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ W m O ■ = � Cn ■ CA � C ■ ■ �DCo = m m-�In—�I a m ■ ■ _zo�M rl■ r ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 16 ■ ■ INNEENNEENNEENEr VENT SIDEWALK EASEMENT IED AREA) 36-129 O I II I II I II I II II I II I II I II I II I II I I I�I I II I II I II I II I II I II I II I II I II I II I �I 0 OPEN SPACE LEGEND COMMON OPEN SPACE 1,002 SF = 4.4% TREE SAVE AREA PRESERVED = 995 SF = 4.4% REPLANTED = 3,585 SF = 15.9% TOTAL = 4,580 SF = 20.3% IMPERVIOUS = 667 SF = 14.6% NATURAL AREA PRESERVED = 995 SF = 4.4% REVEGETATED = 1,295 SF = 5.7% TOTAL = 2,290 SF = 10.1 % CALCULATIONS TOTAL SITE AREA = .52 AC (22,553 SF) COMMON OPEN SPACE REQUIRED = 150 SF (22,533 SF/150 SF/ PER RZ) TREE SAVE AREA REQUIRED = 15% SITE AREA, 150% AREA OF TREE SAVE NOT PRESERVED 22,553*15% = 3,383 SF PRESERVED = 995 SF 3,383-995 = 2,388*1.5 = 3,582 SF ADDITIONAL TREE SAVE REQUIRED TOTAL REQUIRED = 995 + 3,582= 4,577 SF NO MORE THAN 25% OF IMPERVIOUS AREA ALLOWED WITHIN TREE SAVE AREA 4,577*25% = 1,144 SF OF IMPERVIOUS ALLOWED NATURAL AREA REQUIRED = 10% SITE AREA 22,553*10% = 2,255 SF BEFORE YOU DIOI CALL 811 OR 1-800-632-4949 N.C. ONE -CALL CENTER IT'S THE LAWI (71 GRAPHIC SCALE 10 0 5 10 20 U R B A N DESIGN PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 F 704.334.3305 u rbandesignpartners.com nc firm no: P-0418 sc coa no: C-03044 000000000000000 0000� ,�N oCAIQO �0000 �40_000000% 09/30/2020 N U U 0 j N J o � J z O Q) (� (n L 0 O (z ° c� +=J LO r 0 00 CV U znL1' W 8 U� �0 �U 6 Cl) Q a� ) QT_ OT_ Project No: 19-133 Date: 09.30.2020 Designed by: UDP Drawn By: UDP Sheet No: C-3ml 1 INCH = 10 FEET ti f 0 THOMAS ELI BOONE AND DANELLE KINZENBAW BOONE ANNA MILLAR BID # 08109915 : 08109909 BLOCK 4 SECTION 2 FID # BLOCK 4 SECTION 2 ME 151- 43 ZOO 151- ZONED: R-ZONED: R-5 USE: SINGLE FAMILY RESIDENTIAL ■ USE: SINGLE FAMILY 10' BUFFER • RESIDENTIAL ZONE FROM ■ now - TO ■■.P OF BANK • N43 °33'22 "E-150. 27' ■■w■w■ II■11■■■■ ♦ l ■www■■■■■■■■■■•■■■■■■son ■■■■■■■■■ SEE wwwMEMO ■ I I III � T 679 ■■■www■■■w■■■■■w■■■ I • 680� 6$�� I / z i ro I g *SEMME■ - - - - - - - - - - - a ERIN T THOMAS AND o / ° SCOTT BOULET NI p ° PID #: 08109910 ■ ■ ■ ■ D BLOCK 4 SECTION 2 ME 151-43 / 0 ZONED. R-5 / 1 USE. SINGLE FAMILY RESIDENTIAL ) 6_>9 f ■ DRED M DIAGo ELLORENZO DIAGO _ PID #: 08109911 'LOCK 4 SECTION 2 ME 151-45 ZONED: R-5 SE. SINGLE FAMILY RESIDEN TIAL z o■ N� �i R-5 ZONING B-1 ZONING - 1 EXIST. 24" RCP TO rl REMAIN VERTICAL CURVES SHALL BE ■ USED AT EACH SLOPE TRANSITION, TYP. ALLTIME FACTORS, INC PID # 08109912 BLOCK 4 SECTION 2 ME 151-43 ZONED. B-1 USE. COMMERCIAL r GRADE BREAK: 689.64 a ° M9 IF ANY DISCREPANCY IN ELEVATION, AS NOTED ON THE GRADING PLAN, OCCURS ON SITE DURING CONSTRUCTION THE GENERAL CONTRACTOR IS TO CONTACT THE LANDSCAPE ARCHITECT AND CIVIL ENGINEER IMMEDIATELY. I it I rn I III+ SE 24"-30' I NE 24"-30" - 24"-3n" n1/7=r \ �I I I\ I I �- I . ■ ■ I I I I I �I to I� I II I ■ I ■ ■ 11 T ■ I I I I I BOTTOM OF RAMP I ■ GARAGE FFE: 678.37 ■ o ■ i oo ■ I I � ■ Q ■ W i ■ CYI n m ° oo- _ -I T C,)_c-� - T - - - 9F - - - --a-=-rrTM= � r T � \T ■ S43°40' 75.00, ■ ■■ ■ ■ a- PROP. 15' STORM EASEMENT ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ y■■■■■■■■■■■■■■■■■■■■■■■■■.■■■■■■■ -GRADE BREAK: 678.97 I ■ -0 D 00 2 ° �0� o PROPOSED a I �- ■ C � z m �� BUILDING ■ m m I i\\ :.■■■■ W40700■�■■: II II FFE692.87 ii rn� I a ■ II it 1(0 I ■ I I I I I° I I I I -GRADE BREAK: 680.37 I :■■■■■■■■■■■■�■■� ilk Ill -PROP. TRENCH I I I ■ I I II DRAIN I I ti I I III I GRADE BREAK: 682.57 FG: 692.85 II I I I I GRADE BREAK: 685.24 ZAI I I I I I I I I: I I III, FG: 692.74 I I I I ■ I I Its GRADE BREAK: 687.44 I I i I I II I0 I I I ■ !I GRADE BREAK: 688.84 FG:691.53 FG:691.15 i I I a� ,I I �� � I I III IIII TS:6. I GRADE BREAK: 689.44 BS: 6819.78 I I I I a.;I ■ 69 0 FG: 690.02 I �I IIII I GRATE=688.6' ELLIP. IN=684.1' I T I I III ELLIP. OUT=683.8' I /I I / on own. I I III - �FG:689.80- °689.67 FG: S43'40'46, 75.00' AW\ EX RIM: 689.60 < TC: 689.02 �' ° o0 0 ■ �\� RIM=688.9' 689 S 1 ■ 5" I BC: 688.52 J a ""�" ■ \\I \\ ELLIP. 1N=684.3' N=684.4' " ■ N I \\ N 15" 1N=684.4' � � T ELLIP. OUT=684.3' ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■: - - ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ L :■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ IN7W■ ■ ■ ■ ma I I \ \\ - ohe hR- - - - ohe - ohl; Tom\ ■ ■ ■ ■ • - -ohe- - ■ ■ ■ ■ - - - - - - - ■ - - - - - ♦ - - - - --- - ■ ■ ■ ■♦R. C. P. \ r ■ i■■■■■■■■■■■■■■■■■■■■■■■■a ■ ��� I I / ■ ■-w----w----w--�w- �■-■n■-a■u■-■■LR,■■�■■■ Is■ ■ ■ ■ ■ ■ SIMMONS I - f \ - ss- - - - - ss -/- - - f - ss 6 " `o GRA TE= 688.2' 15" our=685.1' DENUDED LIMITS (0.60 ACRES) I I a / SEIGLE AVENUE I I 50' PUBLIC R/W I I CDOT MAINTAINED I I rn 25 MPH SPEED LIMIT I I - - - - - - - -� - - - 15 R.G.P.- _ _ _ _ - - - * � D ----- -v - -T - I���------- _=----TT-T PCSO SUMMARY Original Parcel ID Number(s): 081-099-13, 081-099-14, 081-099-21 Development Type: Multi -Family Subject to PCCO? Y/N No If NO, why? Below BUA/Disturbance Thresholds Watershed: Central Catawba Disturbed Area (ac): 0.60 Site Area (ac): 0.52 DA#1 DA#2 Total on -site Drainage Area (ac): 0.52 Existing Built -upon -area (SF): 13,188 sf (0.30 ac) Existing BUA to be removed (SF): 13,188 sf Existing BUA to remain (SF): 0 sf Proposed New BUA (SF): 17,248 sf (0.40 ac) Proposed % BUA: 76.48% Density (High / Low) High Total Post -Project BUA for site: 0.35 ac (67%) Development or Redevelopment? Redevelopment Natural Area Required (ac): 0.052 ac (2,255 sf) Natural Area provided, total (ac): 0.055 ac (2,380 sf) Undisturbed Treed Natural Area Preserved (ac): N/A Total stream buffer protected on -site (ac): 0.05 ac Transit Station Area? Y/N No Distressed Business District? Y/N Yes Mitigation Type (if applicable) Payment in -lieu Natural Area mitigation? Y/N No Buffer Mitigation? Y/N Yes Total Phosphorous Mitigation? Y/N No GRADING AND STORM DRAINAGE NOTES: 1. ON -SITE BURIAL PITS REQUIRE A PERMIT. 2. ANY GRADING DONE BEYOND THE DENUDED LIMITS INDICATED ON THE CONSTRUCTION DOCUMENTS IS A VIOLATION AND IS SUBJECT TO A FINE. 3. GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION CONTROL PLAN IS A VIOLATION AND IS SUBJECT TO A FINE. 4. ALL FINAL CURB AND STREET GRADES AT INTERSECTIONS SHALL BE COORDINATED WITH INSPECTOR. 5. SIGHT TRIANGLES INDICATED ARE THE MINIMUM REQUIRED. 6. APPROVAL OF CONSTRUCTION DOCUMENTS IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF -SITE GRADING, PERMISSION SHALL BE OBTAINED BY CONTRACTOR FROM THE AFFECTED PROPERTY OWNERS. 7. IN ORDER TO ENSURE PROPER DRAINAGE, CONTRACTOR SHALL MAINTAIN A MINIMUM OF 0.5% SLOPE ON THE CURB. 8. SUBSURFACE DRAINAGE FACILITIES MAY BE REQUIRED IN THE STREET RIGHT OF WAY IF DEEMED NECESSARY BY THE INSPECTOR. 9. THE CONTRACTOR SHALL MAINTAIN EACH STREAM, CREEK OR BACKWASH CHANNEL IN AN UNOBSTRUCTED CONDITION AND SHALL REMOVE FROM THESE AREAS ALL DEBRIS, LOGS, TIMBER, TRASH, JUNK AND OTHER ACCUMULATIONS. 10. ANY CONSTRUCTION OR USE WITHIN THE AREAS DELINEATED AS FLOODWAY DISTRICT FRINGE BOUNDARY LINE OR FLOODWAY DISTRICT ENCROACHMENT BOUNDARY LINE IS SUBJECT TO THE RESTRICTIONS IMPOSED BY THE FLOODWAY REGULATIONS. 11. THE LOCAL ENGINEERING DEPARTMENT HAS NOT REVIEW AND DOES NOT ASSUME RESPONSIBILITY FOR THE STRUCTURAL STABILITY OF ANY EXISTING OR PROPOSED RETAINING WALLS ON THE SITE. 12. NON-STANDARD ITEMS (I.E.: PAVERS, IRRIGATION SYSTEMS, ETC.) IN THE RIGHT OF WAY REQUIRE A LOCAL OR STATE ENCROACHMENT AGREEMENT PRIOR TO INSTALLATION. 13. ALL "CLDSM" NUMBERS REFER TO THE CHARLOTTE LAND DEVELOPMENT STANDARDS MANUAL. 14. ALL SIDEWALKS, STOOPS, TERRACES AND OTHER PAVED AREAS SHALL SLOPE AWAY FROM BUILDINGS) AT A MINIMUM OF 2%. 15. CONTRACTOR SHALL CONTACT INSPECTOR 48 HOURS BEFORE CONSTRUCTION. 16. STABILIZE ALL SLOPES GREATER THAN 3:1 WITH JUTE MESH. 17. ALL ELEVATIONS ARE IN REFERENCE TO THE BENCHMARK WHICH MUST BE VERIFIED BY THE CONTRACTOR PRIOR TO STARTING CONSTRUCTION. 18. ALL CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. REFER TO PAVEMENT CROSS-SECTION DATA TO ESTABLISH CORRECT SUB -BASE, AGGREGATE BASE COURSE ELEVATIONS TO BE COMPLETED UNDER THIS CONTRACT. 19. CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY WITH EXISTING CONTOURS. BEFORE YOU DIOI CALL 811 OR 1-800-632-4949 N.C. ONE -CALL CENTER IT'S THE LAWI C a GRAPHIC SCALE 10 0 5 10 20 U R B A N DESIGN PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 F 704.334.3305 urbandesignpartners. com nc firm no: P-0418 sc coa no: C-03044 CIE 27800 If '''�L/IIIIDII111\\``\ 09/30/2020 L U U 0 N j N J o N J >, 0 O z (� � a'� ' o O M 00 T 0 a. Mi�=j LO L Lr) O N 00 N � U Z O � O rn� �./ W U � �Q N O Q) (1) i V r T_ z 0 W m W Q b z Project No: 19-133 Date: 09.30.2020 Designed by: UDP Drawn By: UDP Sheet No: C-400 INCH = 10 FEET FIRE HYDRANT TEST HYDRANT LOCATION: HYDRANT NUMBER: TEST RESULTS: DATE PERFORMED: TIME: STATIC PRESSURE: RESIDUAL PRESSURE: RESIDUAL FLOW: FLOW @ 20 PSI: VICINITY MAP 1 UTILITY NOTES: 1. 3" DOMESTIC WATER METERS TO BE INSTALLED BY CLT WATER. 6" FIRE LINE WITH DETECTOR METER ASSEMBLY TO BE INSTALLED BY CLT WATER. CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND PAYING FOR INSTALLATION. REFER TO DETAIL "I" & "E" ON SHEET C-8.3 FOR ADDITIONAL INFORMATION. 2. 6" FIRE & 3" DOMESTIC REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION ASSEMBLY AS APPROVED BY CLT WATER AND INSTALLED BY CONTRACTOR DURING CONSTRUCTION. ASSEMBLY TO BE INSTALLED ABOVE GROUND WITHIN INSULATED ENCLOSURE PER CLT WATER REQUIREMENTS. NO PERMANENT INSULATION MAY BE INSTALLED ON THE FIRE ASSEMBLY WHICH IS TO BE INSTALLED ABOVE GROUND WITHIN A HEATED ENCLOSURE (MAINTAIN A MINIMUM OF 40' F). ENCLOSURE TO INCLUDE DRAIN PORT(S) FOR DISCHARGE WATER PER CLT WATER REQUIREMENTS. ENCLOSURE TO BE LOCATED OUT OF SETBACK. REFER TO DETAIL 2 ON SHEET C-8.3 FOR ADDITIONAL INFORMATION. 3. ALL WATER MAINS 6" AND LARGER SHALL BE PVC IN ACCORDANCE WITH AWWA C-900. THE PIPE SHALL BE PRESSURE CLASS 200 WITH SDR OF 14. DUCTILE IRON PIPE (NO PVC) TO BE USED WITHIN 5 FEET OF BACKFLOW PREVENTION DEVICES. 4. MATERIAL AND WORKMANSHIP REQUIREMENTS TO BE IN ACCORDANCE WITH THE CHARLOTTE WATER DEPARTMENT (CLT WATER) WATER AND SEWER POLICIES, PROCEDURES, STANDARDS AND SPECIFICATIONS AS WELL AS THE NORTH CAROLINA DEPT. OF ENVIRONMENT AND NATURAL RESOURCES. IF THERE ARE ANY CONFLICTS BETWEEN THE REQUIREMENTS OF THESE AGENCIES THE MORE STRINGENT SHALL APPLY. THE CONTRACTOR SHALL COORDINATE THE PROPOSED WATER AND SEWER WORK WITH CLT WATER. 5. CONTRACTOR TO VERIFY EXISTING UTILITIES CONNECTION SIZE AND ELEVATIONS PRIOR TO CONSTRUCTION OF ANY UTILITIES ON SITE. CONTRACTOR TO NOTIFY ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. 6. CONTRACTOR TO LOCATE TIE-INS TO ALL BUILDINGS BASED ON PLUMBING PLANS. REFER TO ARCHITECTURAL PLANS FOR ADDITIONAL PLUMBING INFORMATION. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE PRECISE LOCATION OF THE FOLLOWING UTILITIES PRIOR TO BEGINNING CONSTRUCTION: AT&T, BELL SOUTH, PIEDMONT NATURAL GAS, DUKE POWER, CABLE VISION. CALL ULOCO 48 HOURS PRIOR TO COMMENCEMENT OF ANY WORK AT 1-800-632-4949. CALL CLT WATER @ 704-336-2564 FOR LOCATIONS OF EXISTING WATER LINES AND 704-357-6064 FOR LOCATIONS OF EXISTING SANITARY SEWER. CONFLICTS BETWEEN EXISTING UTILITIES AND PROPOSED EXCAVATION SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING ALL PRIVATE WATER AND SEWER LINES IN ACCORDANCE WITH CLT WATER STANDARDS. THE CONTRACTOR SHALL FLUSH, DISINFECT, AND TEST ALL WATERLINES IN ACCORDANCE WITH CLT WATER STANDARDS. ANY PORTION OF THE WATER DISTRIBUTION OR SANITARY SEWER SYSTEMS WHICH DOES NOT MEET THE STANDARDS SET FORTH BY CLT WATER SHALL BE REMEDIED AND RETESTED AT THE CONTRACTOR'S EXPENSE. 9. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE OWNER'S REPRESENTATIVE A MINIMUM OF 48 HOURS BEFORE THE CONSTRUCTION OF WATER AND SEWER LINES TO ALLOW THE OWNER'S REPRESENTATIVE TO PERIODICALLY BE ON -SITE DURING INSTALLATION. THE CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING AS -BUILT DATA OF THE WATER AND SEWER LINES TO THE OWNER UPON COMPLETION OF THE INSTALLATION. 10. THERE SHALL BE NO TAPS, PIPING BRANCHES, UNAPPROVED BYPASS PIPING, HYDRANTS, FIRE DEPARTMENT CONNECTION POINTS, OR OTHER WATER USING APPURTENANCES CONNECTED TO THE SUPPLY LINE BETWEEN ANY WATER METER AND ITS CLT WATER REQUIRED BACKFLOW PREVENTION DEVICE. 11. EACH CLT WATER REQUIRED BACKFLOW PREVENTION ASSEMBLY IS REQUIRED TO BE TESTED BY A CLT WATER APPROVED CERTIFIED TESTER PRIOR TO PLACING THE WATER SYSTEM IN SERVICE. CONTRACTOR IS RESPONSIBLE FOR OBTAINING AN ENCROACHMENT AGREEMENT PERMIT TO CONSTRUCT UTILITY CONNECTIONS. 12. CALL THE BACKFLOW CONSTRUCTION INSPECTOR TO RESOLVE ANY PROBLEMS ENCOUNTERED IN THE FIELD. INSTALLING BACKFLOW PREVENTERS IN A LOCATION AND/OR MANNER OTHER THAN THAT SPECIFIED ON THE PLANS APPROVED BY CLT WATER REQUIRES APPROVAL FROM THE INSPECTOR. OBTAIN SITE ASSISTANCE BY CALLING 704-391-5188. 13. OBTAIN APPROVAL OF BPA INSTALLATION BY CALLING 704-391-5188 TO REQUEST INSPECTION. INSPECTION SERVICE WILL BE PROVIDED WITHIN THREE WORKING DAYS FROM DATE OF REQUEST. APPROVAL BY THE BACKFLOW INSPECTOR IS REQUIRED PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. 14. VERIFY BACKFLOW PREVENTION ASSEMBLY INSTALLATION APPROVAL BY CONTACTING INSPECTOR AT 704-391-5188. CORRECT ALL DEFICIENCIES PER INSPECTOR'S INSTRUCTIONS AND OBTAIN REINSPECTION. 15. BASED ON THE BEST AVAILABLE INFORMATION TO THE DESIGNER, THE BUILDING FIRE PROTECTION SYSTEMS ARE RATED AS A MODERATE HAZARD AND A DOUBLE CHECK VALVE ASSEMBLY IS SPECIFIED FOR INSTALLATION. IT WILL BE NECESSARY TO SUBSTITUTE A REDUCED PRESSURE PRINCIPLE ASSEMBLY IF AT ANY TIME DURING DESIGN OR CONSTRUCTION THE SYSTEMS ARE RATED AS A HIGH HAZARD. 16. TAMPER SWITCHES TO BE INSTALLED ON THE FIRE LINE BACKFLOW PREVENTER. INSTALL 3/4" CONDUIT FROM FIRE LINE BACKFLOW VAULT TO BUILDING ALARM SYSTEM INSIDE BUILDING. COORDINATE WITH ALARM SYSTEM MANUFACTURER. 17. LOCATE FIRE DEPARTMENT CONNECTIONS (FDC) PER FIRE PROTECTION PLANS (BY OTHERS) AND FIRE DEPARTMENT REQUIREMENTS. FDC IS TO BE LOCATED WITHIN 200' OF A FIRE HYDRANT AND WITHIN 50' OF AN ACCESS ROAD ON THE ADDRESS SIDE OF THE BUILDING. 18. ALL 4" SANITARY SEWER LATERALS SHALL HAVE MIN 2.0% SLOPE WITH CLEANOUTS INSTALLED EVERY 100' OR AS PER THE NORTH CAROLINA STATE PLUMBING CODE. LATERAL LOCATIONS ARE APPROXIMATE AND ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. 19. UTILITIES ARE NOT COVERED UNDER THIS DRIVEWAY PERMIT. ENCROACHMENT AGREEMENT MUST BE OBTAINED PRIOR TO INSTALLATION OF UTILITIES WITHIN NCDOT R/W. 1121 SEIGLE AVE 022006 3/12/2020 5:47 78 psi 70psi 3,976.03 gpm 3,388.20 gpm BUILDING NOTES BUILDING SIZE: 13,241 SF (48,371 SF TOTAL) BUILDING TYPE: MULTI -FAMILY DWELLING UNITS TYPE OF CONSTRUCTION: IA FOR PODIUM & VB ABOVE BUILDINGS SPRINKLED? YES 13R THOMAS ELI BOONE AND DANELLE KINZENBAW BOONE £ NNA MILLAR PID #.- 08109975 A PIDJJ MI LLA 09 BLOCK 4 SECTION 2 BLOCK 4 SECTION 2 MB 151- 43 ZOO 151-NED: R-USE: SINGLE FA MILY ZONED: R-5 ♦ ■ USE: SINGLE FAMILY RESIDENTIAL ■ F RESIDENTIAL ■ ■■■■■■ • •II ■"•■ ■w ' ■ ■ ■.. ■ •"SUSSESS DENUDED LIMITS 0.60 AC I / I I �♦ I / a I / ♦ I / ♦♦ ' it ♦ SENSE* ■■■■w - - - - - - - - - - _ z a a a I/ a a J ! ! F F Z 11 III II 4__ - U R B A N DESIGN PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 F 704.334.3305 1 urbandesignpartners.com nc firm no: P-0418 sc coa no: C-03044 ■ I ■ I " Ia ■ 1 ■ In I " � ■ I � II I� ■ ■ ■ I I 1 ■ ■ EXIST. 5/8" WATER METER ■ TO BE DISMANTLED as £ :(METER #117626551) 1 I ■ I 1 ■ ■ ■ ■ ■ ■ I I � I I ■ II ■ ■ Sao I� ■ w II - a m 0 o ' PROP. 20'X1O'X9'D -I Cn :J12 -O OPEN CUT ■ Cn - C -4 1 D o0 2 I ■ MZ ■M ---I c � I PROP. SSCO-2 �- ; 0 D M RIM: 688.73 I I - m m m I ■ I I INV. OUT: 682.25 � i ■ - p I (COORDINATE W/ PLUMBING PROP. BUILDING ONPLANOS) PROP. 6 PVC Pipe 1 29 LF @ 2.48% F \ I a I " PROP. SSMH-1 (DOGHOUSE MH) ■ RIM: 689.10 ■ INV. IN: 681.53 (EXIST. 8") i I I - EXIST. 5/8" WATER METER INV. IN: 681.33 (EXIST. 8") + Iz TO BE DISMANTLED INV. OUT: 681.33 Ms Ms M9 M9 M i I (METER #1015183053) a 3W 3W 3W I ■ rn PROP. BUILDING CONNECTIONS ■ \ (COORDINATE W/ PLUMBING PLANS) I I a ■ � I I I ■ M Q � � I � I 1 ■ I ■ I I Da I ■ ■ PROP. 6" WATER LINE 162 LF TAP TO BLDG rn \ I I ■ IC I i N I I \ \ I ALL TIME FACTORS, INC i I \ L. I ■ I II PID # 08109912 , PROP 3" WATER LINE \ I I I I III BLOCK 4 SECTION 2 3 MB 151-43 (163 L TAP TO BLDG) USE ZONED: COMMERCIAL i• I I t I F y■ i■ ■■ I I III PROP. 3" JA BACKFLOW I �I I III PREVENTER (SE NOTE 2) I = I I I III a • I I� I I I III PROP. 6" RPPA BACKFLOW \ p PREVENTER (SEE NOTE 2) ■ ti■■f ■ " EXIST. 5/8" WATER METER TO BE DISMANTLED BE!■■■■■■■■■■■ " (METER #106110459) ■ ■ o ■ 0 ■ O \ J ■ fl I II PROP. FDC �I I III o�� ■ 1 oo�o ■ I FDA CLEAR a ° oo�o ■ DISTANCE AREA a oo0 ■ a a o ■ 1 I` a ■ ■ ■ ■ • BEFORE YOU DIGI ■ - ohe - - - - - ohe - ohL ■ ■ : ♦ CALL 811 OR 1-800-632-4949 ■ - - _ _ ♦_ _ _ _ _ - L - N.C. ONE -CALL CENTER ■ / - - - - - - - - IT'S THE LAWI --�w ■■■■■■■e■■■:■■■•� I-I f-ss---f-ss- PROP. 12'X6'X5'D EXIST. FIRE HYDRANT N a PROP. 6" FIRE SERVICE W/ OPEN CUT (#022006) 1 1" DETECTOR METER & I 6" DETECTOR CHECK PROP. VALVE PING SEIGLE AVENUE 4 GRAPHIC SCALE (SEE NOTE 1) PROP. 6"X6" TAPPING 50' PUBLIC R/W 1 10 0 5 10 20 SLEEVE & VALVE CDOT MAINTAINED 25 MPH SPEED LIMIT I I 1 INCH = 10 FEET PROP. 90' BEND W/ THRUST BLOCKING, TYP. PROP. 3" DOMESTIC WATER METER (SEE NOTE 1) /// ;'�o��•N'E s CASy SE .. �. 89 09/30/2020 L U 0 J o00 C\1 J ,, U O z D N L p O (z °r° c� LO T LO O N 00 N T N D T Z 0 U) w cr di Q 0 0 Z Project No: 19-133 Date: 09.30.2020 Designed by: UDP Drawn By: UDP Sheet No: C-600 ANNA MILLAR PID #: 08109909 BLOCK 4 SECTION 2 MB 151-43 ZONED. R-5 USE: SINGLE FAMILY RESIDENTIAL EXIST. HIGH HAZARD SILT FENCE ALONG TOP OF BANK (CLDSM: 30.06B) I ERIN T THOMAS AND SCOTT BOULET a PID #: 08109910 m BLOCK 4 SECTION 2 M8 151-43 � ZONED: R-5 USE: SINGLE FAMILY RESIDENTIAL EXIST. SILT FENCES OUTLET, TYP. (CLDSM: 30.06C) 6p I I N, II , MI EDRED M DIA DI�GO PID #: 08109911 I I BLOCK 4 SECTION 2 MB 151-43 I / ZONED. R-5 USE: SINGLE FAMILY RESIDENTIAL GRATE=679.1' I I O� ° ■ 24" IN=675.1' 24" our=675.0' / U \ \ o i ■ \ _ \ 683 R-5 ZONING \ \� lRF B-1 ZONING \ ALL TIME FACTORS, INC PID # 08109912 BLOCK 4 SECTION 2 MB 151-43 ZONED: 8-1 USE: COMMERCIAL I 71 ' _ ► ►fly I I ► II I II I I I I I I I N EXIST. SILT FENCE I I I sus THOMAS ELI BOONE AND ALONG DENUDED LIMITS EXIST. GRAVEL DANELLE KINZENBAW BOONE (CLDSM: 30.06A) I I I I \ TO BE REMOVED BLOCK 4 SECTION / SECTI N I I I I ON 2 MB 151- 43 (t4,850 SF) USE SINGLER MILY EXIST. ASPHALT + ■, I I II RESIDENTIAL TO BE REMOVED f L I RIM =686.3' I ■ I INVERT IN=680.3' (f 1, 080 SF) I I I / INVERT OUT=680.2' ' N43'33' 2"E-750.27' \ \ • IRF ♦♦♦ I ■ ■ 71I-�1iu 6,8 \-��--_; ,__ � S I III GRATE=686.3' C/ \ ■■■■■ / •••■■• •w - I II I ■ II II sE24"-3o"lN=s s.s' ■■ O-- �g------9---9----g-- �' ■ \ - \ ■ ■ ■ s ■U o° 0° \ \ A y- - - 9- r er g- NE 24"-30" 1N=679.8' _ e o 0 0 \ I EXIST. CURB CUT II III 24"-30" our=67�.6' - 679 >. ■ .■■� ° o00000 0 0 0 ° TO BE REMOVED III r ■■■■ O O O O O O \ \ � ASPHALT DRIVE _ I II I ■■. s '� o O o0000 °°°oOOO°00000 ll - j� - �■ 000°oo0°O0 °o°°00000°°°°°°Ooo° \ I m ■ � • °0°00°0°00°° 0000 0° O o ° °0°O ° ° I V ° 0 °Oo°0°0 00 0000°0 00 000000000°0°O°0 I \ �I ~ ♦, ;, 000 ° ° ° 0 1 I II Ili / / I ♦ `l 00 ° ° 000000 0 0 0 00 0 0 O 000000 0 0 O O 0 0 O 000000 0 0 000 O o o O °0°0� / / I + 0 0o0o 0 O O O 0000009000O0 0 00o0000000 \ oD I I\ ° ICI ■ / 1 O00°°0°O0' 00 ° O000 °00 0 0 00C 0 ° °0°°0°O00°�00 I 1 �� ♦ O o p °00 0 0 O 0 O o p0O000°0 O 00 p O O ♦ °,00000000 00°° ° O o 0000 0 0 ° o0 0 0 0 /ooO I 1 ° �.IL.* �■■■■■M Q 000000 o ° OOOo00 0 0 0000°° O OOOOQo o ■ .. I o006000 O °o Oo0 O O °0 0 °Ooo°000 ° °O°°0° O °0°°0 r� 0 0 °°00°000 0000 00 '0°OCCOOOOOOo0oo000000000g00000 0 00 0 0 0 ° 0 0 ° O 0 0 0° 0 0 0 00 0 00 °0 00 o ® \\ = I i O°°0°OCo°00°0 °O0°0° ° 0°0° °° O°00 ° 0 0 0/ 0 0 ti fd'� O o °0 O O °O°O o 0 °o/°o O° 0000000 0°o°O°' o -_ O o 0 O O °O00°°°° OOOOo0°0�000°0°0° °O°°0�00 °O° COVERED ° hoo O o000 0 0 0000 ° 0 0 00 0 0 0 0°° O 00 0 0 0 00 0 1-STORY FRAME °° O O O O O ° °° ° O O O O O O/O ° °O O° O O OO 0 ° RESIDENCE PORCH 24 o O 0 0 0 0° ° 00 0 00 0 0 0 00 ° 0 0 O0 00 NO.82o+ I EXIST. 5/8" WATER METER ° o° O O o0 0 O O oO O O o p0 0 0 0 °0 ° O O Oo 0 00 0o°0000000°°0000 00o0000 0 O000°0°o qboon°0°0 O0°0°O°o °0°0� EXIST. HOUSE, PORCHES, A o p0ooQ000000°000°Oo 00000000 0000000 00000°Oo°o°000°°o°00oOOo0o°0o00Oo0c I TO BE DISMANTLED 0 0 0 ° b STAIRS &UTILITIES ° ° ° ° ° ° ° 0 ° o ° ° o 0000 TO BE REMOVED (METER #117626551) 00 00000 000 0 0 000 oo0000000.0000°�qq°.�QQ° g0o00°°°00000°O°°°°o°/ I I I I ' N' o ° O o p o O 0 0 0 Oo O IQI'AIE ,t$ o0' °O°O0000°OOOOOOo°00 o°000°°° 00000000 000°00 000000 0 0 o 0 0 OoO0 0 0 0 0 0"■;0,0000000°00000000 O 000000000 00000000 0 O000OO 0 Oo00o0°0 000 / II to Co o p p0o°° O o 0 °O°O O 0 O0 0 ° 0�0000 °° °000 0 ° °0°° ° f I \ 0° O 0 o O /0 0 0° 0000° °°° ° IN)) 0 0 0 000000 0 0 0 O 0 (3 OO 0 0 0 O o o O °�n_ O O ° n° O� O FFE=688.8' 0 00 0000 00 0 0 0 O 0000 ° 0 O O° °, 0 ooOO 0 0 oO0 000000° 0°0°o 0 O0°o°o°O °0, EXIST. OVERHEAD III 0 0 000000 000000 0 °0 o O 00°0°0 o °0°0°0 0 °o°o°o 0 00000000000 00000004 000010 00 000000°0 0 0 o ELECTRIC LINES & / °q ■ I I II 0 000° O o 0 0 00 0 0 0000 0 p 0000 0 O Oo°0°O°O 0° �@NC. ° 3 0 0 0 0 00000 0 000Oo 0 000000 0, 0 o0O0 0 0 o POLE TO BE REMOVED / EXIST. CONCRETE I :; 0 000°0000000000 00o00000 o000Oo00001 000>00°0000/0000�J0"0�00�0 0 0 000o 0 000000 0000000 000000 00000 O o 0000 o 00 00000000 0 0Oc 0 TO BE REMOVED I I° ■ I I IIII O 0 0 0 0 00 0 00°0°0 0 °9'O0O ° °O°O°00° / ° % (f30 SF) j I/ ■ I > 0° 0000000°0000 00� " 00000000°0 0 0000000°0 080°°0°0000°0°°° 0 / ° I / ■ y \Ir 3 O O O 0 0 ° O CC�� O ° ° O Q O ° ° O O/ flfl 22 lPF I e j ■ I I I ` 0 0 O o o �'� O 3Cb O O O o 0 0 0 0 0 O 0 �o o N�.3'43'21 £ 75.09' -°�0 O O�O�o 0 0� 0 u--�-�-0 ° 0 ((C 0�90 ��oo C� - - - - - - - ■ I - ° ° °O O 0 0 0 0 00000° ° 00000 ° 000 0 000000 °O°O°0°° ° °O°O O \ bd ohe--■ -ohe----ohe- ohe / O 0 0 O 0 ° 0 0 0 0 ° O O ° o O 0 O 0 ° 0 O O 0 O 0 0 O O ° 22" oh ohe - e-f - ■ O o 0 O Oo°o 0000 0 000000 0 O0 0 140 Oo°0 0 O °O°o ° ° °00 °0 °C � 1 -oh ohe----ohe--- I / O 000610 0 0 00 0 000000 0 OOOo°0 0 00 0 '0 0 -ohe ---ohe--- ---- I 1,4 O O O O O O O O ---ohe- 00�00°0°00°00°O°0°Oo°000 060O°°0°o°O°°°�COo°OC�p° � \ 20 � ' 000°0°00°000°0000 0Ooo, 0 0O00000 000g�,Ooodo°°°0 i� EXIST. TREES II 0 0 0 O o o, 0 0 0 0 ° .0 000000 0 0 o O o O0� r 1 N 0 0 00 00 0 0 0 0600 0 0 ° °0 0 ° ° o TO BE REMOVED TYP. EXIST. ASPHALT 1 °° ■ I ate° I II 0°°o°O°00°°0°o°O° °o°o°O°°00000 0°0°�0°0 ) fl0-00 0o0°0°000 °0-0000 °0000000000°0°90, 9Q�O (QTY: 11 TO BE REMOVED 00 0 0000 0 Oo0o 0 00 �0 000000 0 00o 00 0 Oo°°0-0- 0 ° °0 0° °00000 ° °Q°� ° ° �°0� EXIST. OVERHEAD'°°0° 0°0 0° 00000000�00 0°p°I� 000 00°0 000 o0 o ° ° ° ° ° °� 4 Yo o �0 0 0 ° ° )o OC o O O0o0 O O Oo ° O o 0 O O �j 0 D ELECTRIC LINES &� 0 0 O 0 d o° % 0°- 0 0 o 0 0 0 o p °Coo 0 O Oo0 O Oo 0 0 0 °0q0 O POLE TO BE REMOVED ° °o° 0 °o O -0 ° °O ®J° 00 0 0 °0 0 0 D° U000000 0 0° O 0 °8b- 0 lb o �000° 000 0000000000 °0o00� 0/O00000° ° °0°0 o O OO°000 0 o O0°0 o O °0°O °0000°°°°°O�o°0/ ° °O° °°0°0°0900 Do D( 00 00O0 0o0 0000 00° 000Ooo00 00�0 0C)°0 O o00 O ° 0�000000000000000o0°o 0 �000900°0�Oo000 � 16" \ \ D 0` ° ° 0 0 o O0°0°o o �'0°0°0° °0 °�°0°�0°0 c 0000o000 OOOoDo 0°0°0 0000°o°O0o°J A01 �y l 00 0 0 �5� 0 0 O o 0 O �i O0 0 A °FIES Oo 000 O°0 00°0°o°O °0 00°o O0 < \ \ VEDJ °000000�000000°0°000�%°0° 0°0°0°00 �® ° 0 0°O 0 °°°OOo °OC °0°OoOo00 8"double ° 6g3 ° \` EXIST. CONCRETE /� \ D D L - - �° TO BE REMOVED 0 FFE=686.9' ° (f30 SF) °\ ° e I ° LOT 2 \ EXIST. HOUSE, PORCHES, I LOT I ° I 00STAIRS &UTILITIES ° TO BE REMOVED PORCH 1-STORY FRAME I RESIDENCE NO. 1115 � I i PPETHIS LE GAS AREA I (t580 SF) / I EXIST. OVERHEAD e F° ■ / ■ ° ° I I III ELECTRIC LINES TO ■ ul II BE REMOVED d� �o�m II 111 I� ■°�° �0cq II I►► ASPHALT DRIVE EXIST. CURB CUT I II ► I / TO BE REMOVED I I �D�� II MI / II I EXIST. CONCRETE TO BE REMOVED /ate I °I I I N ■ 4 II GRATE=688.8' / I eELIPU 83(f80 SF) . 66s.1' EXIST. HOUSE, PORCHES & UTILITIES TO BE REMOVED 1-STORY FRAME RESIDENCE NO. 1121 -a e - io 7 z v a m _\ EXIST. CONCRETE ° ° e PROP. 18'X100' A ° DRIVES & SIDEWALK \ CONSTRUCTION ENTRANCE TO BE REMOVED (f4 ) °EPs CLDSM: 30.11 A 0 D \ ,330 SF CONCR rE ° ( ) - ° ° ° EXIST. 5/8 WATER METER DRI TO BE DISMANTLED -° - °689° D D D ,° \ ���,ed (METER #106110459) °��K EXIST. SEWER CLEANOUT $ e B ° ° -� TO BE REMOVED e e 8 D° IRS ° ° d ° ° ° 5 q J4-I IRS a' tl F d ° \ 3`40'46"W-75.00' 4 D • ° ° d NO■ME-^ e e e ° e e ° ° ° ° ° d 689.6' ° \ ° e e e eF1 ° d e d ° e e e ° e e ° e e ° e e ° e e ° e e ° e ■ lI =681a ° \ ° CONCREIt ° ° d ° d d - - e ° 24r' OU,=67844' SIDEWALK ° a- ° ° ° ° ■ I I e ° e d e 4 e \p e P e ° ° ° ° \ d ■ D° D° D° DoU ° d e e e e ° ° ■ -- ---------- ■ CUR C D ° ■ \ ■ ■ BACK OF CURB ■ - - - - - - - - - - - - - -- - - - - - - - -� v- - - - -' - -� Cu UT __ _ CURB C - - - - - - - - - - - - - - - - - - - - - - - - - -� - - - ■ ■ ■ - - - - - - --w----w- w- w----w----w-- 6,-ytH tH rfH HV"■--F■■-■r," 4&." M-q,, aa�■ -a11ill w \,..,... W L- - -- ■ i■■■■■■■■■■■■ ■■■■■■■■■■■i -1 ■ w w-r--w----w----w----w---w----w----w--- w---- 1 EXIST. TREE m■o■ "'■o■oT w 4 TE= 688.8' I I - 1 TO REMAIN' IN=682.0' EXIST. CURB CUT 1 to JUT=682.2' A TO BE REMOVED EXIST. TREEc TO REMAIN PROP. CATCH BASIN I I DENUDED LIMITS j INLET PROTECTION (0.60 ACRES) SEIGLE AVENUE 1 (CLDSM: 30.15) 50' PUBLIC R/W 1 I I CDOT MAINTAINED 1 3 I I 25 MPH SPEED LIMIT 1 I I 689 1 - 1 - - - - - - - - - - - - - -_ _ _ _ _ _ ---------__-_-_-_ -_-- - -- \ \ BACK OF CURB------- GRATE=689.0' \ °� I ° I I I I ■ I � III Jill i I e /e e l / Qe ■ I I I III cONc. ° l I ■ II III - � � °°I dl � I► Ilz I EXIST. 5/8" WATER METER I !° I ° I TO BE DISMANTLED • I ;(METER #1015183053) CO VERED PORCH ° f ° ■ IIII ■ N I I I �I 1 °�Id� : I III IIII F I II I LI . l ..■ 1 � l � � I� I I �I I 1 I III I' I ►I I I I I III I I I I � I I III GRATE=688.6' ELLIP. IN=684.1' II I I III ELL/P. OUT=683.8' ° ■I TJ.�. GRID COORDINATES \ e F I N: 43, 350.07' I I I E:456,127.65' ' 1° Z�88.81' ; ■ I I �\ RIM-688.9' ° ° I ■ T �� S 15" 1N-684.3' d ° d ° ° ° d ■ I I \I ELLIP. IN=684.4' \ N 15" IN=684.4' ° F ■ N \\ ELL/P. OUT=684.3' d d d I • °ohle - - --ohe -I---off - -- ohe- - - -ohL ■ ° - �� \ - --- ----- -- D - - - ♦ ♦ � I 15" R. C. P. � ■� I I / w- ■■n■-aA■■��....■.■ C SS---f-Ss-f--f 98. 2' R/M= 688.9' 35. 1SE INVERT 1N=683.3' I I NE INVERT 1N=682.6' I PROP. CATCH BASIN INVERT OUT=682.4' I INLET PROTECTION 4 / (CLDSM: 30.15) I I I I I� I I� I I I I J 15" R.C.P. EROSION CONTROL NOTES: 1. ALL "CLDSM" NUMBERS REFER TO THE CHARLOTTE LAND DEVELOPMENT STANDARDS MANUAL. 2. ON -SITE BURIAL PITS REQUIRE AN ON -SITE DEMOLITION LANDFILL PERMIT FROM THE NC DEPARTMENT OF ENVIRONMENTAL QUALITY (NCDEQ). 3. ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A VIOLATION AND IS SUBJECT TO A FINE. 4. GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION CONTROL PLAN IS A VIOLATION AND IS SUBJECT TO A FINE. 5. ALL PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3:1 SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS PRACTICABLE BUT IN ANY EVENT WITHIN 7 CALENDAR DAYS FROM THE LAST LAND -DISTURBING ACTIVITY. ALL OTHER DISTURBED AREAS SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS PRACTICABLE BUT IN ANY EVENT WITHIN 7 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY. ALL AREAS MUST BE SEEDED AND MULCHED WITHIN 14 CALENDAR DAYS. REFER TO EROSION CONTROL ORDINANCE FOR ADDITIONAL REQUIREMENTS. 6. ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIRED BY A REPRESENTATIVE OF NCDEQ. 7. SLOPES SHALL BE GRADED NO STEEPER THAN 2:1. FILL SLOPES GREATER THAN 10 FEET REQUIRE ADEQUATE TERRACING (CLDSM#30.16). 8. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF -SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS. 9. THE DEVELOPER SHALL MAINTAIN EACH STREAM, CREEK, OR BACKWASH CHANNEL IN AN UNOBSTRUCTED STATE AND SHALL REMOVE FROM THE CHANNEL AND BANKS OF THE STREAM ALL DEBRIS, LOGS, TIMBER, JUNK AND OTHER ACCUMULATIONS. 10. RETAINING WALLS DESIGNED FOR CRITICAL AREAS (I.E., ON PROPERTY LINES AND R/W) MAY REQUIRE PE SEAL. 11. THE CITY OF CHARLOTTE ENGINEERING DEPARTMENT HAS NOT REVIEWED THE STRUCTURAL STABILITY OF ANY RETAINING WALLS ON THE SITE AND DOES NOT ASSUME RESPONSIBILITY FOR THEM. 12. NON STANDARD ITEMS (IE: PAVERS, IRRIGATION SYSTEMS, ETC.) IN THE RIGHT-OF-WAY MUST HAVE AN ENCROACHMENT AGREEMENT (WITH THE CHARLOTTE DEPARTMENT OF TRANSPORTATION/NORTH CAROLINA DEPARTMENT OF TRANSPORTATION) PRIOR TO INSTALLATION. 13. STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING IS NECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS AND ESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTION SEQUENCE. 14. PERMANENT OUTLETS STRUCTURES SHALL REMAIN SEALED UNTIL SITE STABILIZATION IS ACHIEVED. 15. COIR MESH BAFFLES IN SEDIMENT BASINS SHALL BE USED. SEE SECTION 6.65 OF THE NC EROSION & SEDIMENT CONTROL DESIGN MANUAL FOR ADDITIONAL INFORMATION. MATERIAL SUCH AS 700 G/M^2 EROSION CONTROL BLANKET OR EQUIVALENT SHOULD BE USED. 16. INDIVIDUAL LOT EROSION CONTROL MEASURES WILL BE REQUIRED FOR LOT CONSTRUCTION (SILT FENCE, CONSTRUCTION ENTRANCE AND INLET PROTECTION). DEMOLITION NOTES: 1. EXISTING INFORMATION ON THIS PLAN WAS TAKEN FROM A SURVEY PREPARED BY: A.G. ZOUTEWELLE SURVEYORS 1418 EAST FIFTH STREET CHARLOTTE, NC 28204 (704) 372-9444 2. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS. 3. HOLD ON SITE PRE -CONSTRUCTION MEETING WITH CHARLOTTE LAND DEVELOPMENT EROSION CONTROL INSPECTOR PRIOR TO ANY DEMOLITION. 4. SITE IS OCCUPIED BY EXISTING BUILDINGS, STORM LINES, PAVEMENT, POWER POLES AND UTILITIES. IT IS CONTRACTORS RESPONSIBILITY TO CONTACT ALL UTILITY COMPANIES THAT MAY HAVE UTILITIES ON THE SITE TO GET A DETERMINATION IF ANY UTILITIES EXIST THAT WILL BE IMPACTED AND DETERMINE THE REQUIRED PROCEDURE FOR ABANDONMENT OF THE EXISTING UTILITIES. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND SEQUENCING OF DEMOLITION OR RELOCATION OF UTILITIES WITH APPLICABLE UTILITY COMPANY. 6. CONTRACTOR TO REMOVE EXISTING STRUCTURES AS DIRECTED BY OWNER. CONTRACTOR TO REMOVE STRUCTURES, FENCES, SHEDS AND MISC. DEBRIS. 7. ALL MATERIAL GENERATED BY THE DEMOLITION, CLEARING AND GRUBBING SHALL BE HAULED FROM THE SITE BY THE CONTRACTOR IN ACCORDANCE WITH ALL THE CHARLOTTE-MECKLENBURG HEALTH DEPARTMENT AND THE ENVIRONMENTAL PROTECTION DEPARTMENT REGULATIONS AND ORDINANCES. 8. ALL AREAS WHERE PAVEMENT, BUILDING SLABS, FOUNDATIONS, UTILITIES, CONDUITS, AND/OR UTILITY STRUCTURES HAVE BEEN REMOVED SHALL BE BACKFILLED WITH SELECT BACKFILL MATERIAL. ALL SELECT BACKFILL MATERIAL SHALL BE PLACED AND COMPACTED PER THE REQUIREMENTS OF THE SPECIFICATIONS AND THE ON -SITE GEOTECHNICAL ENGINEER. 9. ALL WORK WITHIN THE STREET RIGHT OF WAY SHALL BE IN CONFORMANCE WITH ALL APPLICABLE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION AND CITY OF CHARLOTTE DEPARTMENT OF TRANSPORTATION REQUIREMENTS. 10. CONTRACTOR SHALL MAINTAIN TWO-WAY TRAFFIC AT ALL TIMES WHEN WORKING WITHIN EXISTING STREETS. THE CONTRACTOR SHALL PLACE AND MAINTAIN SIGNS, DANGER LIGHTS, BARRICADES, AND FURNISH WATCHMEN OR FLAG MEN TO DIRECT TRAFFIC IN ACCORDANCE WITH THE WORK AREA TRAFFIC CONTROL HANDBOOK (W.A.T.C.H.). MAINTENANCE PLAN: 1. ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING MORE THAN 0.5" RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY TO MAINTAIN ALL PRACTICES AS DESIGNED. 2. SEDIMENT WILL BE REMOVED FROM THE SEDIMENT TRAPS AND INLET PROTECTION DEVICES WHEN STORAGE CAPACITY HAS BEEN APPROXIMATELY 50% FILLED. GRAVEL WILL BE CLEANED OR REPLACED WHEN THE SEDIMENT POOL NO LONGER DRAINS PROPERLY. 3. SEDIMENT WILL BE REMOVED FROM BEHIND THE SEDIMENT FENCE WHEN IT BECOMES ABOUT 0.5 FT DEEP AT THE FENCE. THE SEDIMENT FENCE WILL BE REPAIRED AS NECESSARY TO MAINTAIN A BARRIER. 4. ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED ACCORDING TO SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A VIGOROUS DENSE VEGETATIVE COVER. EROSION CONTROL LEGEND: CONSTRUCTION ENTRANCE ........... DENUDED LIMIT SILT FENCE CATCH BASIN INLET PROTECTION EM -ohe -t- uge ugt w - g- 0 STONE SILT FENCE OUTLET PROPOSED STORM DRAINAGE BEFORE YOU DI431 EXISTING STORM DRAINAGE CALL 811 OR 1-800-632-4949 N.C. ONE -CALL CENTER EXISTING OVERHEAD ELECTRIC IT'S THE LAW1 EXISTING TELEPHONE EXISTING UNDERGROUND ELECTRIC 71z, EXISTING UNDERGROUND TELEPHONE EXISTING WATER LINE EXISTING GAS LINE GRAPHIC SCALE 10 0 5 10 20 EXISTING UTILITY POLE I MEMO MEMO MEMO MEMO 1 INCH = 10 FEET U R B A N DESIGN PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 F 704.334.3305 urbandesignpartners.com nc firm no: P-0418 sc coa no: C-03044 Q4z CSEAL - 90 4��"A, G E.• 09/30/2020 i N U U J O O Cz 0 >N o coN U a) z N o 00 T 0 1..1..E .O O E L0 06 T ro 00 ^ I.L N Z 0 0 O= cz U U6 _ Q ■ � O(D Q a) ' U) O T W r z 0 U) w m w Q 0 O z Project No: 19-133 Date: 09.30.2020 Designed by: UDP Drawn By: UDP Sheet No: C-700 ANNA MILLAR PID #: 08109909 BLOCK 4 SECTION 2 MB 151-43 ZONED: R-5 USE. SINGLE FAMILY RESIDENTIAL ti N I II I I I I I I I EXIST. SILT FENCE I 8s I II THOMAS ELI BOONE AND ALONG DENUDED LIMITS I I \ DANELLE KINZENBAW BOONS PID 08109915 (CLDSM: 30.06A) I # BLOCK 4 SECTION 2 I MB 151-43\I I \ 1 ZONED: R-5 USE: SINGLE FAMILY RESIDENTIAL \i■_■ ■ ■ I Ir I ^ \ I I II h ■ ■ / h IN IRF I N „3 3" 2"E-150,27' IRF_ ♦♦ E TNTi I I � \ � ■� ■■ •■■■■I■■■■■■■w I IC ■ ■ II I■•"■■ I I I I - EXIST. HIGH HAZARD SILT I / /� v \ ' ; ♦ 680� FENCE ALONG TOP OF BANK (CLDSM: 30.06B) z ERIN T THOMAS AND SCOTT BOULET �I PID #: 08109910 ■ ■ r BLOCK 4 SECTION 2 MB 151-43 ZONED: R-5 USE: SINGLE FAMILY 2 RESIDENTIAL cTj EXIST. SILT FENCE OUTLET, TYP. (CLDSM: 30.06C) ■ IRF a ■ ti I C) � MILDRED M DIAGO4N&- _ ELLORENZO DIAGO PID #: 08109911 BLOCK 4 SECTION 2 ti MB 151-43 I I Q ZONED:R-5 USE: SINGLE FAMILY RESIDENTIAL GRATE=67.1' 5 24" OUT=675.0' \ \ \ / 6&1 \ 683 \ R-5 ZONING \ IRF B-1 ZONING \ \ 0 n� z (7) ALLTIME FACTORS, INC ti PID #: 08109912 0 BLOCK 4 SECTION 2 m� MB 151-43 II m ZONED: B-1 rn m USE: COMMERCIAL o �~ O `2 PROP. 18'X100'- CONSTRUCTION ENTRANCE (CLDSM: 30.11 A) SIDEWALK & UTILITY EASEMENT (DB 23928-167) n �o \ ■■M- ■ 0 0 0 0 4"=678.4' z ■ I II C II\ I I II I I I� I ITT■■* � \ II m \ I � II I III III \ I II\ 6 II I I I I ■/ � I ��� I 1111 I I I 'Y �� III IIII ■ I I I II I I I I III I F N ' I I IIIII I II I I I I IIIII w I I II I �oo!'i II III II _cri II III u,�c-+ II I I I I ■ uDCo= I 1 I m2EC/) \I I oD_TM� II I m �m \ II II I m II I I l I I I F I ■............ ♦ ..: III I I II I I i I � II I IIII J I^�I I i ►'I'IIII I I I I �dl II / I I I' I I I IIII I I■ I II o I � I I■ � I I III I� I I I I II 0 NO I I I III I I I I ■I � I II I LO\ �� I �■■■.■ � �� I III II PERMAN NT SIDEWALK EASEMENT I III it DBA733 129TCH EA) I / 6 1 1 IIII RAT E I \ I IIII ELLIP. ►I E ■' ►N.i. GRID COORDINATES F I N.• 43,350.07' III E 456,127. ze88.81' `/ I I -SIDEWALK & U4LITY EASEMENT (DB p55J=ff±W IRS S43'4046"W-75.00' _ - lR - ■ II \ \� I I \ ' 689 ■ \ , ■ \ ■ FIBER OPTIC LINE I J I ■ I \ NOT MARKED - -ohe - - - ohe - - ♦ - - - I ■ 0 0 0 0 '� \ ■ ■ ■ ■ ♦ ohe----ohl? \ ■ ■ L s - - - - - - - ■ C ■ - ■ BACK OF CURB ■ - - - ■ ♦ 1.� R C.P. I - \ - - - - - - ■ - - - - ■ ---w----w----w�---w----w-- ,�■!!■!■!■e■ e■.l�e■e■!eleee■■!■e■■■■■!■! �90■ \ ■ ■ w-t--w--- - - - -w--liEl��!!�!!!!!!!!!!!!!!!!!i - - - - - - - - - - ♦•♦ r m \1 EXIST. TREE ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ * - W - - - W - - - - W -w-- w- .!■■.!■.■.■.!■■ • S rE=666.8' - - \ 1 \ TO REMAIN' IN=682.0' is OUT=682.2' :I I --"48.2' RIM=688.9' EXIST. TREE N I I -, \ s9 I \ 3s.1' SE INVERT /N=683.3' N a I I I g \ � 1 J0 PROP. CATCH BASIN I 1 DENUDED LIMITS TO REMAIN NE INVERT /N=682.6' PROP. CATCH BASIN INVERT OUT=682.4' I I la j INLET PROTECTION I I (0.60 ACRES) SEIGP AVENUE INLET PROTECTION I (CLDSM: 30.15) AV (CLDSM: 30.15) tiro /� 50'I O I I I I CDOT MAINTAINED 25 MPH SPEED LIMIT I I 'b I I - - - - - - - - - - - - -\ _ _ _ _,- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15=R.C.P.- - - - - - \ - * D 18 1 ------------------ \ I --------- \ ----- - ----,�_----_ - - -I -1 ------------ ---- iT-T - BACK OF CURB 3 - - - - - - - - - - - - - - - - - - - - GRATE=689.0' \ \ 18" IN=682.3' \ I I No 18" OUT=682.6' GRATE=688.2' GRATE=688.2' 2 CONSTRUCTION SCHEDULE: 1. OBTAIN PLAN APPROVAL AND OTHER APPLICABLE PERMITS FROM CHARLOTTE LAND DEVELOPMENT. 2. FLAG THE WORK LIMITS AND BUFFER AREAS FOR PROTECTION. 3. HOLD ON -SITE PRE -CONSTRUCTION CONFERENCE WITH CHARLOTTE LAND DEVELOPMENT EROSION CONTROL INSPECTOR TO DISCUSS EROSION CONTROL MEASURES. FAILURE TO SCHEDULE SUCH CONFERENCE 48 HOURS PRIOR TO ANY LAND DISTURBING ACTIVITY IS A VIOLATION CODE AND IS SUBJECT TO A FINE. 4. INSTALL CONSTRUCTION ENTRANCE, SILT FENCE, INLET PROTECTION, TREE PROTECTION AND OTHER MEASURES AS SHOWN ON PLANS. COMPLETE DEMOLITION ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEDIMENT BASINS SHALL BE STABILIZED IMMEDIATELY UPON INSTALLATION. 5. CALL FOR ON -SITE INSPECTION BY INSPECTOR. WHEN APPROVED, INSPECTOR ISSUES THE GRADING PERMIT AND CLEARING AND DEMOLITION MAY BEGIN. 6. COMPLETE SITE CLEARING. REMOVE OR RE-ROUTE EXISTING UTILITIES THROUGH THE SITE INCLUDING LIGHT POLES, UNDERGROUND UTILITIES AND STORM DRAINAGE PIPES. 7. CONSTRUCTION ALONG SEIGLE AVE AND E 15TH ST SHOULD BE HELD UNTIL LATER PHASES. THE SIDEWALK SHALL REMAIN OPEN FOR PEDESTRIANS. CONTRACTOR SHALL INSTALL SILT FENCE AND OTHER BARRIERS AS NEEDED TO ENSURE THE SAFETY OF PEDESTRIANS. 8. THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES. EFFECTIVE OCTOBER 1, 2010, PERSON RESPONSIBLE FOR LAND DISTURBING ACTIVITIES MUST INSPECT THE SEDIMENT AND EROSION CONTROL MEASURES ON A PROJECT AFTER EACH PHASE OF THE PROJECT TO MAKE SURE THAT THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN IS BEING FOLLOWED. SELF -INSPECTION REPORTS ARE REQUIRED. 9. FOR PHASED EROSION CONTROL PLANS, CONTRACTOR SHALL MEET WITH EROSION CONTROL INSPECTOR PRIOR TO COMMENCING WITH EACH PHASE OF EROSION CONTROL MEASURES. 10. ROUGH GRADE SITE, STOCKPILE TOPSOIL, CONSTRUCT CHANNELS, INSTALL CULVERTS AND OUTLET PROTECTION, AND INSTALL SEDIMENT FENCE AS NEEDED. MAINTAIN DIVERSIONS ALONG TOP OF FILL SLOPES DAILY. 11. AFTER GRADING IS COMPLETE INSTALL STORM DRAINAGE AND OTHER UTILITIES. INSTALL INLET PROTECTION AT ALL CATCH BASINS AND STORM INLETS. ONCE COMPLETE, RUNOFF SHOULD BE DIVERTED TO INLETS. INLET PROTECTION MUST REMAIN IN PLACE WITHIN THE WORK AREA UNTIL ALL AREAS OF THE PROJECT ARE STABILIZED. 12. FINISH THE SLOPES AS SOON AS ROUGH GRADING IS COMPLETE. LEAVE THE SURFACE SLIGHTLY ROUGHENED AND VEGETATE AND MULCH IMMEDIATELY. 13. COMPLETE FINAL GRADING OF GROUNDS, TOPSOIL CRITICAL AREAS, AND PERMANENTLY VEGETATE, LANDSCAPE, AND MULCH. REFER TO LANDSCAPE PLAN FOR ADDITIONAL INFORMATION. 14. ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE INSPECTED WEEKLY AND AFTER 0.5" RAINFALL EVENTS. NEEDED REPAIRS WILL BE MADE IMMEDIATELY. 15. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INC EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, US DEPT. OF AGRICULTURE, CITY OF CHARLOTTE EROSION CONTROL ORDINANCE, AND THE CHARLOTTE LAND DEVELOPMENT STANDARDS MANUAL. 16. COORDINATE WITH EROSION CONTROL INSPECTOR PRIOR TO REMOVAL OF EROSION CONTROL MEASURES. AFTER SITE IS STABILIZED, REMOVE ALL TEMPORARY MEASURES AND INSTALL PERMANENT VEGETATION ON THE DISTURBED AREAS PER THE LANDSCAPE PLAN. EROSION CONTROL LEGEND: L I CONSTRUCTION ENTRANCE ■---- - - - - -■ DENUDED LIMIT SILT FENCE OCATCH BASIN INLET PROTECTION STONE SILT FENCE OUTLET PROPOSED STORM DRAINAGE EXISTING STORM DRAINAGE - ohe - EXISTING OVERHEAD ELECTRIC - - - t EXISTING TELEPHONE - - - Uge EXISTING UNDERGROUND ELECTRIC - - - Ugt EXISTING UNDERGROUND TELEPHONE - - - w EXISTING WATER LINE - - - g- EXISTING GAS LINE o EXISTING UTILITY POLE BEFORE YOU DIGI CALL 811 OR 1-800-632-4949 N.C. ONE -CALL CENTER IT'S THE LAW1 71z, GRAPHIC SCALE 10 0 5 10 20 INCH = 10 FEET U R B A N DESIGN PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 F 704.334.3305 urbandesignpartners.com nc firm no: P-0418 sc coa no: C-03044 09/30/2020 L U U 0 > o J o00 C\1 J ,, U 0 �z L N o O Cz 00 T ONIONEEN LO LO 0.00 N O Z O� U U � Q O(D (D O U) T U) W T r z O w di Q 0 O z Project No: 19-133 Date: 09.30.2020 Designed by: UDP Drawn By: UDP Sheet No: C-701 0 4 GROOVE JOINT IN SIDEWALK 1/8" RADIUS L GENERAL NOTES: 1. A GROOVE JOINT 1" DEEP WITH 1/8" RADII SHALL BE REQUIRED IN THE CONCRETE SIDEWALK AT 5' INTERVALS. ONE 1/2" EXPANSION JOINT WILL BE REQUIRED AT INTERVALS OF NOT MORE THAN 45' AND MATCHING EXPANSION/CONSTRUCTION JOINT IN ADJACENT CURB. A SEALED 1/2" EXPANSION JOINT WILL BE REQUIRED WHERE THE SIDEWALK JOINS ANY RIGID STRUCTURE. 2. SIDEWALK AT DRIVEWAY ENTRANCES TO BE 6" THICK. 3. WIDTH OF SIDEWALK ON THOROUGHFARE STREETS SHALL BE A MINIMUM OF 6'. WIDTH OF SIDEWALKS IN THE CENTRAL BUSINESS DISTRICT WILL BE DETERMINED BY THE CDOT. 4. WIDTH OF SIDEWALKS ON NON -THOROUGHFARE STREETS SHALL BE BASED ON TYPICAL STREET SECTION, A MINIMUM OF 5'. SIDEWALK TO BE POURED TO END OF RADIUS AT INTERSECTING STREETS. 5. CONCRETE COMPRESSIVE STRENGTH SHALL BE 3600 PSI. IN 28 DAYS. 6. ZONING CONDITIONS MAY REQUIRE ADDITIONAL WIDTH SIDEWALKS WHICH SHALL SUPERSEDE THESE STANDARD DIMENSIONS SHOWN. 7. LIDS FOR JUNCTION BOXES AND UTILITY VAULTS SHALL BE NON-SKID AS SPECIFIED BY ENGINEER. 8. JOINT MATERIALS SHALL LIMIT SHRINK/SWELL SO POST CONSTRUCTION INSTALLATION RESULTS IN A MAXIMUM OF 1/4" FROM FLUSH. 1/8" TO 1/4" JOINT FILLER 1/2" TRANSVERSE EXPANSION JOINT IN SIDEWALK U oD 1/2" EXPANSION JOINT 50% (2.00% MAX.) EXAMPLE SIDEWALK CONSTRUCTION DIMENSIONS: WIDTH RISE CROSS -SLOPE 1.56% 4' 5' 1.67% 6' 1-" 1.56% 8' 1-3" 1.56% \�•• •• .��PROPOSED CURB & GUTTER PROPOSED 4" CONCRETE SIDEWALK DETAILS SHOWING EXPANSION JOINTS IN CONCRETE SIDEWALK 0 NOTES: 1. ALL CONCRETE TO BE 3600 P.S.I. 1/2" EXP. JOINT\ COMPRESSIVE STRENGTH. 2. AT ALL DRIVEWAYS, SIDEWALKS TO BE z REMOVED TO THE NEAREST JOINT BEYOND NEW CONSTRUCTION OR CUT WITH A SAW AND REMOVED. SAW CUT OR JOINT TO BE PERPENDICULAR TO EDGE OF EXISTING n PAVEMENT. SEE STD. NO. 10.17 FOR JOINT DETAIL. 3. ALL DRIVEWAYS MUST MEET THE CURRENT CITY PLANTING STRIP DRIVEWAY REGULATIONS AND NCDOT REQUIREMENTS FOR SPACING, SIGHT DISTANCE, A AND OFFSETS FROM PROPERTY LINES AND INTERSECTIONS. 4. "A" BREAKOVER SHALL BE 8% OR LESS (A -ALGEBRAIC DIFFERENCE). 1/2" EXP. JOINT 5. PRIOR APPROVAL IS REQUIRED BY CDOT ON GRADES EXCEEDING THE GRADES SHOWN ON THIS DETAIL. 6. **PER NC IFC SECTION D103.2, FIRE APPARATUS ROADS SHALL NOT EXCEED 10 PERCENT IN GRADE. 7. JOINT MATERIAL SHOULD BE PLACED FLUSH WITH CONCRETE. TOP OF CURB 8. THIS DETAIL IS ONLY FOR USE WHEN PLANTING STRIP IS 6' OR LESS IN WIDTH. USE TYPE II -MODIFIED DRIVEWAY 10.25E WITH LARGER PLANTING STRIP. 11 DRIVEWAYS CLASSIFICATION TYPE DRIVEWAYS MINIMUM MAXIMUM ONE-WAY TYPE II - 20' 30' COMMERCIAL TWO-WAY TYPE II - 26' 50'* COMMERCIAL * NEED MORE THAN ONE CONTRACTION JOINT IN CENTER. NOT TO SCALE • CITY OF CHARLOTTE • CITY OF CHARLOTTE LAND DEVELOPMENT STANDARDS CONCRETE SIDEWALKS STD. N0. REV. �rn LAND DEVELOPMENT STANDARDS � � aABLOTTE. INCLUDES CHARLOTTE ETJ 110.22 1151 CHARMTE. INCLUDES CHARLOTTE ETJ DRIVEWAY WIDTH VARIES B� Y X d Q s 1 $ I� GROOVE JOINT I 1I I GROOVE JOINT OR 1 CONSTRUCTION JOINT - - - - 1 I I BEVEL CURB TO MEET DRIVEWAY PAVEMENT DRIVEWAY WIDTH VARIES (SEE TABLE) B PLAN VIEW DRIVEWAY WIDTH VARIES SECTION A -A M yPLANTING STRIP 1 /2" EXP. JOINT OP OF CURB FRONT EDGE OF WALK ("�'.SEENO,TE 4) "A» VARIES A%** 6"� 5'-0" MIN.- (4 (4' MIN) 4 6» 2 09�Xl.5% (2.00% MAX.) +6% **SEE NOTE 6 1L -2% Tr r �_i0'-0" 10'-0" SECTION B-B NOT TO SCALE COMMERCIAL DROP CURB TYPE II DRIVEWAY WITH PLANTING STRIP STD. NO. REV. (2' 6" CURB AND GUTTER) 10.25B 19, 0 0 vc�56o 46°0,0000 a& ° 46 0,00 cc& 0 000 016 � o°d �\°�°ho°dJ°�o dJ° OdJ° 0 0 0 0 0� 00 0 0 0 0sq RRO o 0bo 66o o O 6bo 0 0 o d J \\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\\ HEAVY DUTY CONCRETE 1.5" SURFACE COURSE 3" INTERMEDIATE COURSE 8" COMPACTED AGGREGATE 8" REINFORCED CONCRETE SURFACE COURSE 8" AGGREGATE BASE COURSE COMPACTED SUBGRADE 1.5" SURFACE COURSE 1.5" INTERMEDIATE COURSE 6" COMPACTED AGGREGATE rooO ° 0 00 °COO O° °C)o\° ocpo v °dJ°�o °� d�aXc° COMPACTED SUBGRADE °� o�oV v °dJ°�o �°dB°��� COMPACTED SUBGRADE 0 00 0 0 0 0000 00 0 0 08q RR 0 0 0000 00 0 0 08 RR 0 6bo 0ooO 6bo 6bo °o O 6bo o o dJ0 o 6 �01 O 6bo o CO&�O o dJ0 0 HEAVY DUTY ASPHALT CROSSSECTION TYPICAL ASPHALT CROSS SECTION NOTES: 1. GEOTECHNICAL ENGINEER SHALL REVIEW AND APPROVE ASPHALT PAVEMENT AND CONCRETE DESIGN PER ACTUAL SOIL CONDITIONS AND OWNERS LOADING REQUIREMENTS PRIOR TO START OF CONSTRUCTION. 2. HEAVY DUTY ASPHALT PAVEMENT SHALL BE PROVIDED FOR ALL FIRE APPARATUS ACCESS ROADS AND DESIGNED TO SUPPORT AN 80,000LB LOAD. PAVING CROSS SECTIONS SCALE: NTS 0 0 AAll�l�yy1�7 1/8" RADIUS (TYPICAL) SURFACE OF GUTTER ° a d JOINT FILLER J TRANSVERSE EXPANSION JOINT NOTES: 1. CONTRACTION JOINTS SHALL BE SPACED AT 10-FOOT INTERVALS. FOR VALLEY GUTTER, A 10-FOOT SPACING MAY BE USED WHEN A MACHINE IS USED. JOINT SPACING MAY BE ALTERED BY THE CITY ENGINEER TO PREVENT UNCONTROLLED CRACKING. 2. CONTRACTION JOINTS MAY BE INSTALLED BY THE USE OF TEMPLATES OR FORMED BY OTHER APPROVED METHODS. WHERE SUCH JOINTS ARE NOT FORMED BY TEMPLATES, A MINIMUM DEPTH OF 1 1/2" SHALL BE OBTAINED. 3. ALL EXPANSION JOINTS SHALL BE SPACED AT 90-FOOT INTERVALS, AND ADJACENT TO ALL RIGID OBJECTS. JOINTS SHALL MATCH LOCATIONS WITH JOINTS IN ABUTTING SIDEWALK. 4. CONCRETE COMPRESSIVE STRENGTH SHALL BE 3600 P.S.I. IN 28 DAYS. 5. CURB SHALL BE DEPRESSED AT INTERSECTIONS TO PROVIDE FOR FUTURE ACCESSIBLE RAMPS. 6. TOP 6" OF SUBGRADE BENEATH THE CURB AND GUTTER SHALL BE COMPACTED TO 100% STANDARD PROCTOR DENSITY. NOT TO SCALE • CITY OF CHARLOTTE LAND DEVELOPMENT STANDARDS CURB AND CUTTER 11�CHARLOTTE. INCLUDES CHARLOTTE ETJ 10.1 7 C UP TO 1.5% TOP OF CONCRETE CURB (BEYOND) BACK OF CURB RAMP SLOPE UP TO \ DETECTABLE WARNING (2.0% MAX) 7.5% (8.33% MAX\1/2" EXPANSION JOINT SEE DETAIL 10.35B sw TRANSITION II PANEL - SEE SIDEWALK TRANSITION PANEL - SEE NOTE 5 TA TOE OF RAM * * * * * * * * * NON -WALK SURFACE NOTE 5 2' MIN. l 6W * * * • a o RAMP SLOPE A VARIES- uP MATCH 2" TO 5.0 6^ SIDEWALK WIDTH SEE 2'-6" CURB DETECTABLE WARNING 2' MIN WIDTH IN R6" * RADIUS VARIES * * * * * CONCRETE * * SIDEWALK (OR TURNING SPACE IF AND GUTTER DETAIL BELOW DIRECTION OF PEDESTRIAN TRAVEL SECTION A -A F THERE IS AN INTERSECTING RAMP, A TURNING SPACE/LANDING IS REQUIRED WITH 1.5% (2% MAX.) CROSS SLOPE AND RUNNING SLOPE INTERSECTING RAMP) ;" FLOWLINE DEPTH AT RAMP LOCATION PLAN RAMP RUNNING EDGE OF SW SITION EL UP TO 5% MAX.) (2� MAX) 1.5% (2% MAX) SLOPE UP TO 7.5% 1/2" EXPANSION JOINT (TYP,) PAVEMENT (8.33% MAX) (INCLUDES DETECTABLE* * CROSS -SLOPE * NON -WALK SURFACE * * * WARNING)* * 1.5% (2.00% MAX * * * , 2'-6" *** I CURB AND GUTTER ********** * * * * * rGE OF RAMP 2'-6" CURB AND GUTTER DETAIL * * VARIES MAXIMUM SLOPES FOR CURB AND GUTTER DEPRESSION AT DIRECTIONAL RAMPS 2"*TO* y y y NOTES: 1. USE THIS DETAIL ONLY UNDER THE FOLLOWING CIRCUMSTANCES: C 5-FOOT SIDEWALKS WITH CURB RADII OF 35 FEET OR LESS • 6_FOOT SIDEWALKS WITH CURB RADII OF 30 FEET OR LESS CURB HEIGHT . 8-FOOT SIDEWALKS WITH CURB RADII OF 25 FEET OR LESS VARIES 0" TO 6" 1• y/ SIDEWALK TRANSITION 2. DIRECTIONAL RAMPS WITH RETURNED CURBS AS SHOWN MAY BE USED WHEN A PLANTING SEE NOTE 2 PANEL - SEE NOTE 5 STRIP (NON -WALK SURFACE) IS PROVIDED. DO NOT USE THIS DETAIL IF THERE IS HARDSCAPE (WALKABLE SURFACE) INSTEAD OF A PLANTING STRIP. IF A WALKABLE SURFACE IS ADJACENT TO RAMP CONSTRUCT CONCRETE FLARES WITH SLOPES UP TO 10% MAX, INSTEAD OF CONSTRUCTION JOINT (TYP.) RETURNED CURBS. 3. ALL CONCRETE SHALL BE AT LEAST 3600 PSI. 4. ENSURE FLUSH CONDITIONS AT RAMP TO GUTTER TRANSITION. PERSPECTIVE 5. SIDEWALK TRANSITION PANEL: PREFERRED DESIGN IS 1.5% (2.0% MAX) IN ALL DIRECTIONS IN FRONT OF GRADE BREAK & DRAIN TO FLOW LINE. RUNNING SLOPE OF THIS AREA MUST NOT EXCEED 2%. CROSS SLOPE MAY MATCH STREET GRADE AT BACK OF CURB WHEN STREET GRADE >2%. TRANSITION TO 1.5% (2.0% MAX) CROSS -SLOPE AT TOE OF RAMP. THIS DETAIL IS NOT FOR USE IN ETJ, OR ON NCDOT-MAINTAINED STREETS. NOT TO SCALE • CITY OF CHARLOTTE DIRECTIONAL CURB RAMP LAND DEVELOPMENT STANDARDS CHARLOTTE. WITH SMALL/MEDIUM CURB RADII STD. No. 10.40A REV. 17, NOTES: 1. THIS DETAIL PRESENTS ALTERNATIVE TREATMENTS FOR THE SIDES OF THE RAMP - RETURNED CURBS, RECTANGULAR WINGS, AND ANGLED WINGS. 2. ENSURE FLUSH CONDITIONS AT CURB RAMP TO GUTTER TRANSITION. 3. TYPICALLY, THE SIDEWALK RUNNING SLOPE SHALL NOT EXCEED THE GENERAL GRADE ESTABLISHED FOR THE ADJACENT STREET. 4. CURB RAMPS WITH RETURNED CURBS MAY BE USED ONLY WHERE PEDESTRIANS WOULD NOT TYPICALLY WALK ACROSS THE RAMP, THE ADJACENT SURFACE IS PLANTING OR OTHER NON -WALKING SURFACE, OR THE SIDE APPROACH IS SUBSTANTIALLY OBSTRUCTED. TURNING SPACE/LANDING 1.5% (2% MAX.) CROSS -SLOPE AND \A RUNNING SLOPE \B W 0 � * * * * * * * * \ GUTTER RECTANGULAR WINGS • CITY OF CHARLOTTE LAND DEVELOPMENT STANDARDS CtIARtMTE- INCLUDES CHARLOTTE ETJ TURNING SPACE/LANDING 1.5% (2% MAX.) CROSS -SLOPE AND RUNNING SLOPE \A B *** * * * * * * * * * * * * * * * * CONCRETE CURB W * * * * (SEE NOTE 4) * * * GUTTER RETURNED CURBS (SEE NOTE 4) TURNING SPACE/LANDING 1.S- (2% MAX CROSS -SLOPE AND RUNNING SLOPE A W * * * *W**** * * * * *** ANGLED WINGS PERPENDICULAR CURB RAMP WITH 2'-6" CURB AND GUTTER NOT TO SCALE 1 0.31 9116 U R B A N DESIGN PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 F 704.334.3305 u rbandesign partners. com nc firm no: P-0418 sc coa no: C-03044 CAROB' X� L =_ 78 .�'QjLNG '•.•, IN �. 09/30/2020 ^L W Ile o U �.J 0 0 Q j N J CN° J z ��{{ a� \V '0'^ vJ �i a L m O O C� 00 T U = 0-) 0 V n4-1 W 0 r °6 v/ d N 00 OC) �+ Z U o (� U o �> ■ � V J a_i 0 T ■ T V ♦ T Project No: 19-133 Date: 09.30.2020 Designed by: UDP Drawn By: UDP Sheet No: C-8mO • m MATERIAL AND DIMENSIONS PER MANUFACTURER'S SPECIFICATIONS U 2'-4" CLEAR 0 3'-4" 8'** w U a L� 0 z o PLATE ANCHORS OR 3' EMBEDDED MOUNTING m d 1 J �J d SIDE VIEW 15" to 30" 8'** CLEAR U 0 0 L 3'-6" 2'-4" CLEAR Q II� z 0 J 3,* 5 m J a Q z WALL, BUILDING FACE, OR CURB PLAN VIEW * 5' MINIMUM SEPARATION FROM CURB FACE WHEN INSTALLED ADJACENT TO A CURB WITH "HEAD -IN" AUTOMOBILE PARKING ** MEASURED FRON NEAREST VERTICAL COMPONENT OF NEIGHBORING RACK • CITY OF CHARLOTTE LAND DEVELOPMENT STANDARDS Ctupa TTE- INCLUDES CHARLOTTE ETJ SEE SITE PLAN FOR CONDITION REFER TO MANUFACTURER INSTRUCTIONS FOR INSTALLATION & POST FOOTERS (5) #4 REBAR CONT. AS SHOWN COMPACTED SUBGRADE""" 2,000 PSF SAFE BEARING PRESSURE TO BE VERIFIED #4 REBAR 16" O.C. #3 REBAR CONT. IN CORNERS AS SHOWN 0 NOTES: 1. BIKE RACK GENERAL REQUIREMENTS: • SHOULD SUPPORT THE BICYCLE UPRIGHT WITHOUT PUTTING STRESS ON THE WHEELS • SHOULD ACCOMODATE A VARIETY OF BICYCLES AND ATTACHMENTS • SHOULD ALLOW LOCKING OF FRAME AND AT LEAST ONE WHEEL WITH U-LOCK • SHOULD PROVIDE SECURITY AND LONGEVITY FEATURES APPROPRIATE FOR THE INTENDED LOCATION • SHOULD BE INTUITIVE 2. BIKE RACKS SHOULD BE INSTALLED PER MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES. 3. ALTERNATIVE BIKE RACKS OR LOCKERS MAY BE USED BUT ARE SUBJECT TO APPROVAL OF THE CHARLOTTE DEPT. OF TRANSPORTATION. 4. ALL DIMENSIONS SHOWN ARE MINIMUM. 5. RACK MUST BE CANE DETECTABLE. RACK AND CLEARANCES SHOWN ARE TO BE OUTSIDE THE PEDESTRIAN ACCESSIBLE ROUTE. TYPICAL MOUNT OPTIONS: SURFACE PLATE BASE WITH ANCHORS (NOT PERMITTED IN PAVER BRICK SURFACE) NVERTED "U" RACK FOR BICYCLE PARKING TUBULAR ALUMINUM HANDRAIL IN -GROUND EMBED INTO CONCRETE BASE NOT TO SCALE POURED IN PLACE CONCRETE, 4,000 PSI @ 28 DAYS, REF 0'-4" LAYOUT FOR NUMBER OF TREADS AND RISERS 0'-OY" 2 „ 0'-6 #3 REBAR CONT. @ EACH STAIR NOSING 1'-DY„ �- 2 • e u SL E -III �. � '•. III -III •° �` 1- o __�� I �-III-I I • .� •, , • III=1 I I °III- R .°• SEE SITE PLAN ' _•.-I FOR CONDITION 2" EXPANSION JOINT NOTE: 1. HANDRAIL TO BE APPROVED BY LANDSCAPE ARCHITECT AND OWNER PRIOR TO INSTALLATION r 8 � 6" RISER CONCRETE STEPS SCALE: NTS 50.20 11 5 RECOMMENDED MINIMUM COMPACT 10 w W w PARKING ANGLE 90° o (TWO WAY OPERATION ONLY) o o W o I o J lai J ldi J I u<i 3 3 3 I I NOTES: 18'-6" 26'-0" 18'-6" 18'-6" 23'-0" 17'-0" 16'-0" 21'-0" 15'-0" 1. FOR ACCESSIBLE PARKING o, is STANDARDS/SIGNAGE SEE STDS. 1 1 50.1OA, B, AND C. 2• PAVEMENT MARKINGS SHALL BE 4" a o a D a WHITE PAINT. V) U N U In U PARKING ANGLE 60` o 0 0 0 0 0 3. ALTERNATIVE PARKING ANGLES, (ONE WAY OPERATION ONLY) a w a w a w AISLE WIDTHS, AND OPERATION 0 1 g 0 1 1 0 1 (TWO-WAY ANGLED PARKING OR J J J REVERSE -ANGLE PARKING) WILL 3 3 3 BE CONSIDERED BY CDOT ON A CASE -BY -CASE BASIS. 20'-6" 16'-0" 18'-6" 18'-0" 16'-0" 16'-6" 15'-0" 14'-0" 14'-0" 1 1 C',C I I N a a,a a,a ^� m 0:to U N U U PARKING ANGLE 45° o o W a IL (ONE WAY OPERATION ONLY) a o ¢ o a o Q 1 a Q 1 Q Q 1 a 3 3 3 �I 19'-6" 12"-0" 16'-6" 17'-6"12'-0" 16'-0"_ 14'-0" 12'-0" 13'-0- • CITY OF CHARLOTTE LAND DEVELOPMENT STANDARDS CHARLOTTE- INCLUDES CHARLOTTE ETJ NOT TO SCALE R EXISTING SIDEWALK <" F I <' J<" D KEY CURB AND GUTTER SIDEWALK TRANSITION DETAIL AT BACK OF CURB Not to scale R EXISTING SIDEWALK r J D R r 0'-2,9' 10' 4' 3'-7.9' 25' 19' 8'+ 50' 44' </ --- -- <i F L L1 J J </ </ � L--- - I- r --- R SIDEWALK TRANSITION DETAIL (PLANTING STRIP BOTH SIDES) Not to scale • CITY OF CHARLOTTE LAND DEVELOPMENT STANDARDS S D E WA L K T R A N S T O N � STD. N0. REV. CHARLOTTE- INCLUDES CHARLOTTE ETJ 1 0.2 1 g e R7-8P DIMENSIONS (INCHES) A B C 0 E I F G H J k L 12 1 fi 1 3/8 1 3/S 1-i/2 ,-,/2D i/2 1D 2-,/2 4 1-1/2 c �A N SIGN R7-8P ACCESSIBLE RESERVED PARKING SIGN R7-8 FAAXIMUM 1111SIGN PENALTY CLDSM #50.10C $ 250 °J . INCREASE SPACING SO;G FINISHED GRADE D-FHWA (FEDERAL HIGHWAY ADMINISTRATION/USDOT) SERIES D LETTERS a . LEGEND AND BORDER - GREEN BACKGROUND - WHITE NOT TO SCALE • CITY OF CHARLOTTE SUPPLEMENTAL VAN ACCESSIBLE LAND DEVELOPMENT STANDARDS SIGN R 7 - 8 P ST➢. CHABU T[E INCLUDES CHARLOTTE ETJ 50.1 OE31 18, 2' 6" STANDARD CURB & GUTTER ADDITIONAL PARKING BAYS AND REVERSE CURVES/CHAMFERS --PROVIDE CATCH BASIN OR SLOPE PARKING AREA TOWARD STREET FLOW LINE AS APPROPRIATE. Q7 VL PARALLEL -PARKING PC j� PAVEMENT MARKINGS \\ 1 I PER MUTCD (TYP.) \ . . . . . . . . . EDGE OF TRAVEL LANE r� 22' MIN. - NOTES: 1. REVERSE CURVES/CHAMFERS NOT NECESSARY IF ADEQUATE DRAINAGE CAN BE PROVIDED THAT WILL ENSURE THAT SEDIMENT, WATER, DEBRIS, ETC., DOES NOT COLLECT IN 90-DEGREE CORNERS. 2. PARALLEL ACCESSIBLE SPACES AND LOADING ZONES TO BE REVIEWED BY CDOT ON A CASE -BY -CASE BASIS. 3. FOR PARKING BAYS THAT ARE 8 FEET IN WIDTH OR GREATER, THE PAVEMENT MARKINGS SHALL BE SET AT ONE (1) FOOT LESS THAN THE STALL WIDTH. 4. GREATER SEPARATION FROM INTERVENING STREETS THAN THE DISTANCES PROVIDED IN THE MATRIX MAY BE REQUIRED AT CDOT'S DISCRETION. 5. POSITIVE DRAINAGE SHALL BE PROVIDED EITHER BY INSTALLATION OF APPROPRIATE DRAINAGE STRUCTURES OR SLOPE PARKING AREA TO STREET FLOW LINE. SLOPING PARKING AREA TO STREET FLOW LINE ONLY PERMITTED IF ROAD GRADE IS GREATER THAN 2%. 6. IF A BIKE LANE IS REQUIRED ADJACENT TO PARALLEL PARKING, THE MINIMUM WIDTH OF BIKE LANE IS 6'. • CITY OF CHARLOTTE MEASURE DISTANCE TO NEXT INTERVENING STREET OR ACCESSIBLE RAMP FROM THIS POINT. z z 20 Q a w a J U J OJ a m (SEE MATRIX BELOW) 1:1 CHAMFER MAY BE PROVIDED IN LIEU OF REVERSE CURVES AS SHOWN. STREET MINIMUM DISTANCE TO NEXT INTERVENING STREET DRIVEWAY LOCAL/ COLLECTOR TH'FARE LOCAL/COLLECTOR 20' 20' 20' THOROUGHFARE 20' 20' 50' NOT TO SCALE PARKING STANDARDS STD. NO. REV. M LAND DEVELOPMENT STANDARDS PARALLEL PARKING STANDARDS STD. N0. RE CJfIARLOTTE_ INCLUDES CHARLOTTE ETJ 50.09C1 8 50.09A L NOTES: 1. AN ACCESS AISLE SHALL BE PROVIDED AT STREET LEVEL FOR ON -STREET PARALLEL PARKING WITH 5' MIN. WIDTH AND SHALL EXTEND THE FULL LENGTH OF THE PARKING SPACE. 2. ACCESSIBLE SPACE AND ACCESS AISLE SHALL BE OBSTRUCTION -FREE. 3. ALL CONCRETE TO BE 3600 P.S.I. 4. SEE STD NO 10.18 FOR DETAIL OF 18" VERTICAL CURB. 5. SEE STD. NO 10.17E FOR DETAIL OF EXPANSION JOINT AND GROOVE JOINT. 6. GUTTER FLOW LINE SHALL BE MAINTAINED THROUGH THE ACCESS AISLE. 7. ACCESSIBLE PAVEMENT MARKING DETAIL: • INSTALL INTERNATIONAL SYMBOL OF ACCESSIBILITY PARKING SPACE MARKINGS, INCLUDING WHITE SYMBOL WITH BLUE BACKGROUND AND WHITE BORDER. SYMBOL SHALL HAVE MIN. HEIGHT OF 28 INCHES AND MIN. WIDTH OF 24 INCHES (EXCLUSIVE OF BLUE BACKGROUND AND WHITE BORDER). STROKE WIDTH SHALL BE MIN. 3 INCHES. • WHITE PAVEMENT MARKINGS PLACED ON CONCRETE SHALL BE SHADOWED WITH BLACK BORDER. • TYPICAL SYMBOL LOCATION AND ORIENTATION PER "DIAGRAM A" BELOW 8. PROPOSED TREES MUST BE PLANTED 6-8' AWAY FROM THE BACK OF ACCESS AISLE CURB. 9. SPECIFY STD. NO. 40.11, "BRIDGING TREE ROOTS" IF ENCROACHING ON GROWING SPACE OF TREE. 10.LOCATE IN MOST LEVEL AREA OF BLOCK (RECOMMENDED PRACTICE) TO MAXIMIZE USABILITY. 11. CURB LINE SHIFTS TOWARD RIGHT-OF-WAY TO ACCOMMODATE ACCESS AISLE. 12. SPACE AND ACCESS AISLE SHOULD HAVE SMOOTH SURFACE FOR LIFT DEPLOYMENT. MINIMIZE CROSS SLOPE FOR LIFT OPERATION. 13. PARKING METER FOR ACCESSIBLE SPACE - PROVIDE A CLEAR APPROACH AREA WHERE PARKING METERS ARE REQUIRED. COORDINATE WITH CDOT FOR METER LOCATIONS. 14. FOR MORE INFORMATION SEE SECTION R309 OF "PROPOSED GUIDELINES FOR PEDESTRIAN FACILITIES IN THE PUBLIC RIGHT-OF-WAY" (PROWAG). 15. USE SIGN "C" AS SHOWN ON STD. 50.10A FOR ON -STREET PARKING. • CITY OF CHARLOTTE LAND DEVELOPMENT STANDARDS (�IARLOTIE INCLUDES CHARLOTTE ETJ ON -STREET PARKING SPACES REQUIRED TOTAL NUMBER OF MARKED OR METERED PARKING SPACES ON THE BLOCK PERIMETER MINIMUM NUMBER PARKING REQUIRED OF ACCESSIBLE SPACES 1 TO 25 1 26 TO 50 2 51 TO 75 3 76 TO 100 4 101 TO 150 5 151 TO 200 6 201 AND OVER 4% OF TOTAL (BASED ON TABLE R214 OF PROWAG) 1 DIAGRAM A ACCESSIBLE ON -STREET PARALLEL PARKING U R B A N DESIGN PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 F 704.334.3305 u rbandesign partners. com nc firm no: P-0418 sc coa no: C-03044 09/30/2020 U U 0 j N J CNo J z O a� c� a L 4-1 p CD r= U = 0-)U T V W LO r °6 V♦ O d C\1 Co ON U cz U o W U L U rn � ^` W W ■ T V ♦ T T Project No: 19-133 Date: 09.30.2020 Designed by: UDP Drawn By: UDP Sheet No: C-8ml m n Z O r Z H 1 n CD Norco =rnZ c C� D 4 v =n v D m a z N 0 1-I m Z O _ SHEET 1 DF 2 840.02 t BACK OF CURB on X °' y •• o� °' ----- o.' PLAN X m SECTION Y-Y RISER HT. VARIES .0 6" • o WHERE 30" TO 38" PIPE IS USED RISER HT. VARIES o A .•-'6-"'a'-�i all o WHERE 42" TO 54" PIPE IS USED DETAIL SHOWING METHOD OF RISER CONSTRUCTION v vm ~� S rti Z allCD E� O m Z m = � D #4 BARS "V" 6 X1 =�zAm @EQUAL SPACES . 1N2 ` 3" =CD=oo z -0 �•I r 00" - W co 2z D yy rch LL Z v W �w co all s PLAN OF TOP SLAB m 0 Z O r Z .. �0CD N � _ Cn g" E� #8 "W" BARS n n rn Z @4EQUAL SPACES c C� D Ln � v C) v 4 BAR _ W g SECTION R-R m a Z Co 0 z TI Z SHEET 2 OF 2 840.02 v vm H� 0 �• z � 0 -n CID mz =� =-nZDm =CAOO Z"-0--n nDy> Cn O z ei z oG) Z r N = rn = rn C C D Cn D Z v O r v 1--1 = z �o� H = Z M O Z z m r W 0 X O _ SHEET 1 OF 1 840.31 SECTION X-X SEE SEU7IUN J-J WHERE 30" TO 36" PIPE IS USED GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL CATCH BASINS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.56. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. USE TYPE "E", "F" AND "G" GRATES UNLESS OTHERWISE INDICATED. FOR 8'-0" IN HEIGHT OR LESS USE 6" WALLS AND BOTTOM SLAB. OVER 89 0" TO 16'-0" IN HEIGHT USE 8" WALLS AND BOTTOM SLAB. ADJUST QUANTITIES ACCORDINGLY. CONSTRUCT WITH PIPE CROWNS MATCHING. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. ..°� e v p•::I Q% •:ul I LL O .I • Nr.. PLAN SECTION M-M WHERE 42" TO 54" PIPE IS USED M o:.o: 'o: o::.:o::.o: =.o: M r •�1 A . n1 m oD PLAN EXPANSION JOINT 4'-6" 4'.6" 6" STD. 840.03 FRAME, 1„ GRATE &HOOD c o00000000��m0�0 M - W 6,-O., y y PLAN °d Q LL CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES go *k UJ TOP g„ ELEV. m a, USE ON FLAT EXPANSION JOIN GRADES 2% AND UNDER 3'-0" DEPRESSED GUTTER LINE EXPANSION JOINT 3' O I SECTION S-S ELEVATION NORMAL CURB AND GUTTER ON LIGHT GRADES NORMAL GUTTER LINE #4 BAR EXPANSION JOINT all B TOP a USE ON GRADES VER Z� ELEV. DEPRESSED GUTTER LINE EXPANSION JOINT 10" I 6 0' q" 1»_ F DOWEL ELEVATION NORMAL CURB AND GUTTER ON STEEP GRADES MINIMUM DIMENSIONS AND QUANTITIES FOR CONCRETE CATCH BASIN(BASED ON MIN. HEIGHT, H, WITH NO RISER) DIMENSIONS OF BOX AND PIPE COVER DIMENSION CU. YDS. CONIC. IN BOX DEDUCTIONS ONE PIPE PIPE SPAN WIDTH WIDTH SPAN NIN. HEIGHT BARB-U BARS-V BARS-W TOTAL TOP SLAB BOTTOM $LAB TOT•CONC. FOR NINIMN HEIGHT. H D A B C G H E F NO. LENGTH NO. LENGTH NO. LENGTH LBS. 12" 3'-0' 2'.2" -- -- 2'-9" -- -- -- -- -- -- -- -- -- -- 0.235 0.772 0.015 10.028 15" 3'-0' 2'-2" 3'-0" 0.235 0.829 0.023 0.036 18" 9'-0" 2'-2" 3'-3" 0.235 0.887 0.033 0.049 24" 3'-0" 2'-2" W-9" 0.235 1.001 0.059 0.085 30" 3'.0" 2'.2" W-411 4'-S" 1'.2" 4'.0" 4 1'-5" 2 3'-9" 3 3'-9" 39 0.123 0.321 1.433 0.092 0.127 38" 3'-0' 2'-2" W-10" 4'-9" 1'-8" 4'-0" 4 1'-11" S W-9" 3 3'-9" 43 0.181 0.358 1.714 0.132 0.178 42" 3'-0" 2'-2" 4r-5" 5 -3 1'-5" 3'-2" 4 1'-8" 2 2'-11" 3 2'-11" 92 0.112 0.318 1.798 0.180 0.243 48" 3'-0" 2'-2" 5'-01, 5'-9" 2'-0" 3'-2" 4 2'-3" 3 2'-11" 3 2'-11" 35 0.146 0.352 2.062 0.235 0.317 54" 3'-0" 2'.2" 5'.7" 8'-3" 2'-7" 3'.2" 4 W-10" 5 2'-11" 3 2'.11" PLAN J SEE N TE '� DOWEL SECTION Y-Y AL MANHOLE E i- D I.' T I. D QUO 1 I' - mati 3" If M 1,0.54 C FOR MANHOLE COVER & FRAME #4 BARS "A" OPTIONAL SPACED 6" C. TO C. BRICK MAY BE USED TO ADJUST FRAME & COVER TO SURFACE ELEVATION MAX. 1' OUTLET PIPE .� o EORF Lill, SECTION C-C OR D-D 41 0.180 0.388 2.387 0.297 0.401 * RISER HAS .228 CUBIC YARDS OF CONCRETE PER FOOT HEIGHT GENERAL NOTES: CHAMFER ALL EXPOSED CORNERS 1". USE CLASS "B" CONCRETE THROUGHOUT. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS TO CONSTRUCT THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF BOX, ADD TO BASE AS SHOWN ON STANDARD NO. 840.00. PROVIDE ALL JUNCTION BOXES OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTERS IN ACCORDANCE WITH STD. NO. 840.66. ADJUST THE STEEL, CONCRETE AND BRICK MASONRY QUANTITIES TO INCLUDE THE ADDITION OF THE MANHOLE (I.E. DIAGONAL BARS SHORTENED AROUND OPENING IN TOP SLAB, ADDITIONAL VARIABLE HEIGHT BRICK MASONRY, OPENING IN TOP SLAB.) MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP ELEVATION IS 12 FEET. T #4 BAR 61, DOWEL DIMENSIONS AND QUANTITIES FOR CONCRETE JUNCTION BOXES DIMENSIONS OF BOX AND PIPE REINFORCEMENT BARS "A" TOP SLAB DIMENSIONS CUBIC YARDS IN BOX TOTAL QUANTITIES BOX AND SLABS DEDUCTIONS FOR ONE PIPE CU.YDS. PIPE SPAN WIDTH HEIGHT D A B H N0. LENGTH E F TOP SLAB BOTTOM SLAB WALLI FT. OF HT. LBS. REINF CU. YDS. MIN. "H" C.S. R.C. 12" 2'.0" 2'-0" 2'-3" 12 2'-9" 3'-0" 3'.0" 0.167 0.167 0.185 22 0.750 0.015 0.024 15" 2'.3" 2'-3" 2'-6" 12 3'-0" 3'-3" 3'-3" 0.196 0.196 0.204 1 24 0.902 1 0.023 0.036 18" 2'-8" 2'-8" 2'-9" 14 3'-3" 3'-8" 3'-8" 0.227 0.227 0.222 30 1.085 0.033 0.049 24" 3'-0. 3'-0" 3'-3" 16 W-9" 4'-0" 4'-0" 0.296 0.296 0.259 40 1.434 0.059 0.085 30" 3'-6" 3'-6" 3'-9" 18 4'-3" 4'.6" 4'-6" 0.375 1 0.375 0.298 51 1.860 0.092 0.127 36" 4'.0" 4'-0" 4'-3" 20 4'-9" 5'-0" 5'-0" 0.483 0.463 0.333 64 2.341 0.132 0.178 42" 4'.6" 4'-6" 4'-9" 22 5'-3" 5'-6" 5'-6" 0.560 0.560 0.370 77 2.878 0.180 0.243 48" 5'.4" 5'-4" 5'-3" 26 6'.3" 6'.4" 6'-4" 0.743 0.743 0.407 111 1 3.623 0.235 0.317 54" 6'-10" 5'-10" 5'-9" 28 GI W-10" 8'-10" 0.865 0.865 0.444 1 126 F 4.283 0.297 0.401 ev GI 8'-8" 6'-3" 30 7'.3" 7'.6" 7'-8" 1.042 1.042 0.481 145 1 5.090 0.367 0.495 60" 7'.1" 7'.1" 8'-9" 32 7'-10" 8'-1" 8'-1" 1.210 1.210 0.518 169 5.917 0.444 0.589 Z O N H Q HCL=C,3U LLJCL"Z LU CL LL Q 0 O LLO U)OON¢ Z ,j= ~ 0 oUJ Ir O Z LL 1-"1 CD N Z 3 00 wa Xi cc = a LO < < W x H F- o W - =r^ ,I�` N V! V T J Z CD O z v w HEET 1 OF 2 840.02 z 00 �< ¢ ��CCD LLJCL"z OOCn= cc aQ=00 CAHLLOJ ooCD¢ 1z NH Cr EL H 00 _ 0 Z LL N (D Co ~ Im a < CL Ili O � � oOC Q U7 < V Z3 z °C ¢ W F_ co W x = = N (n 0 J Z O z O Z w HEET 2 OF 2 840.02 z oN ZI=C=3U LLJdFiZ O O O = cca0�OH U) LL0J OO"¢ Z ?•_ H a w o LL O t7 m J 7+ O Z H O V J is �Z¢z co o o C H o ~ C/) I~1 r (D z V W SHEET 1 OF 1 840.31 CITY OF CHARLOTTE STANDARD CITY OF CHARLOTTE STANDARD CAST IRON FRAME AND COVER. CAST IRON FRAME AND COVER (BOLT DOHV-WATER TIGHT) RMSHED GRADE E BRICK OR CONC. GRADE GS FOR ADJUSTMENT OF N 24"FLUSH 7R/N MANHOLES ,y 7' MI 2' r 2 N J' 16" O.0 v O HEIGHT OF RISER AND CONE 5£CITON VARIES (GN STRAIGHTWALL) STRAIGHT WALL OF M.H. TO BE LOCATED OVER INFLUENT PIPE (4'0 M.H.) 2 4'-0' OR 5'-0" m FLEXIBLE COUPLING CAST IN BASE ORJ INSTALLED IN CORD HOLE WTH STAINLESS STEEL COMPRESSION DEVICE. FOR 8" AND 10" PIPE, INVERTS ARE TO BE 314" PIPE LID AT TROUGH, FOR 12' AND LARGER PIPS PROVIDE FULL INVERT AS SHONN. THE -SHELF SHALL SLOPE 2" fROM WE MANHOLE WALL TO THE TROUGH. W NOTES. - I. MANHOLE TO CONFORM W 7H ASTM C478 EXCEPT AS MODIF7ED BELOW. 2. MANHOLE BASE TO BE REINFORCED WITH A MINIMUM AREA OF 0.20 SO, IN. PER LINEAL FOOT EACH WAY. WALL REINFORCING TO BE MINIMUM OF 0.12 SO. K PER LINEAL FOOT. EITHER TONGUE OR GROOVE SHALL HAVE REINFORCING EQUAL IN AREA TO MINIMUM OF WALL SECRON. J. ALL JOINTS SHALL CONFOOM WITH AS7M C443. 4. STEPS TO BE PLASTIC PER CITY STANDARDS 5. ALL PIPE OPENINGS TO BE NO GREATER THAN 3" LARGER THAN OUTSIDE DIAMETER OF PIPE AND ADDITIONALLY REINFORCED WITH A MINIMUM OF a20 SO. IN. OF STEEL AT 90 DEGREES.(ADDITOINAL REINFORCING NOT REQUIRED FOR CORED OPENINGS) 6. ALL SURFACES SHALL BE SMOOTH EVEN TEXTURED WITH A MINIMUM OF HONEYCOMB, FINS AND OTHER IMPERFECTONS. 7. PENETRA77NG L/F17NG HOLES SHALL BE PLUGGED W)TH EXPANSION GROUT. 8. INVERTS MAY BE 3600 PSI READY MIX CONCRETE IN LIEU OF BRICK. PRECAST INVERTS ARE ACCEPTABLE. 9. STEPS IN 5' DIAMETER MANHOLES TO BE OVER WIDEST SHELF. 10. 4 0' CONE SECTIONS MAYBE USED WITH 5 0 MANHOLES WITH A 5'-4" TRANSITION SECTION PLACED DIRECTLY BENEATH THE 4 0 CONE. 11. ALL MANHOLE SEC77ONS SHALL BE DESIGNED FOR H-20 LOADING 12. MINIMUM HEIGHT FOR CONCENTRIC CONES ON MANHOLES WITH BOLT DOWN F&C IS 32". CHARLOTTE-MECEa NBURG UTILITY DEPARTMENT ENGINEERING DIVISION CHARLOTTE, NORTH CAROLINA Job No, TO No. STANDARD DETAIL PLAN `-ems- SEWER PRECAST MANHOLES 4' AND 5' DIAMETER July 27, 1995 XV-60 Sewer Specifications/Details (SD) COVER TO READ *SEWER* SEE NOTE t -, VARIES 4 W 3' -0' MAX _1 SEE NOTE W O a 4.5' BEND -/ TWO PIECE CAST IRON VALVE BOX, RATED FOR TRAMC LOADING " . �r1111111111 IF �ONNEGT NEW LATERAL PIPE T E�"ISTiNG I._kIERAL NTH RUBBER U-EEVE COUPUNG %% N STD, NI ES:S STEEL COMPRESSION BANDS AND $HEAR RINGS (FERNCO OR EQ(JAL). COUPLING TO BE MIN. 4® WIDE. a • 1 4 •-B. i 1-1 - S »� I�. �P►1�]t;�l�L'i 3M�»�L��iI CONCRETE THRUST BLOCK 4"o & LARGER TEE 4"0 & LARGER CONCRETE THRUST BLOCK I- =III=III=1 =III=III=III=III=111- �` ". III1=1I o o Q e' 0 ° o. 'n . •. N ;e.;....-III- Q . • > .e .'<:; " ICI -ICI . e. �� L UNDISTURBED EARTH PLAN ELEVATION NOTE: CARE SHALL BE TAKEN WHEN PLACING THRUST BLOCKS TO KEEP THE FITTING BOLTS FREE OF CONCRETE. of ®mmm• m m� 00m® • ®0m0 ml • • ��mm ml 8 • �®®m ml ' • �mm ml • g ��m :S THRUST BLOCKS - DIMENSION "A" 1 I 12/07I UTILITIES, INC. LOGO ADDED I SAO IU. DATE REVISION BY URBAN DESIGN PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 F 704.334.3305 urbandesig n partners.com nc firm no: P-0418 sc coa no: C-03044 \\�IIIIIII111III/ 19 ���. cr !VGINE. * 09/30/2020 L U j N J CNo J >, U O CD z • Ln _ i 4.1 m _o O M 00 T- U = T_0 V I MIMI n+I W LO r °6 V / C) 0 70 C: CD ON U Z U o ■ T1 r ^VJ U) Cn T- T- z 0 > w } m w Q 0 0 z Project No: 19-133 Date: 09.30.2020 Designed by: UDP Drawn By: UDP Sheet No: C-802 A A/2 A/2 =1 I —I I-1 I-1 I-1 I-1 I-1 _I1 I-1 I—UNDISTURBED EARTH CONCRETE THRUST BLOCK CONCRETE THRUST BLOCK =III=III—lii =III—III=III III- -II- IIII illlll l=1 o . II o Q E 40 4"0 2 R LARGER LARGER E 0� 0 Q =1=1 o=1 . II —III —III— a TEE —I I1 , 11=III=III=III=III=III= =III=III=III= 'i1-11111,111,;,111=III-1 �lllllilllll�lllll- UNDISTURBED EARTH PLAN ELEVATION NOTE: CARE SHALL BE TAKEN WHEN PLACING THRUST BLOCKS TO KEEP THE FITTING BOLTS FREE OF CONCRETE. THRUST BLOCKS — DIMENSION $$A$) FILE NO. WATER DETAILS SCALE: N.T.S. TYPICAL THRUST BLOCK ° AUG. 2003 FOR TEES 5701 Westpark Dr., Suite 101 IiiC: P.o. Box 240908 STANDARD DETAIL NUMBER 1 12 07 UTILITIES, INC. LOGO ADDED SAO �fljlNES Charlotte, N.C. 28224-0908 and NC/TN Affiliates (704) 525-7990 `n/_ � 1/ N0. DATE REVISION BY SIZE 11 1/4° BEND 22 1/2° BEND 45° BEND 90° BEND TEE PLUG 4 12 12 12 16 16 14 6 12 12 12 16 16 14 8 12 12 16 22 22 18 10 12 14 20 28 28 22 12 12 18 24 32 32 28 14 14 20 28 38 38 32 16 16 22 32 42 42 36 18 18 26 36 48 48 40 20 20 28 40 52 52 44 24 24 34 46 64 64 54 30 30 42 58 78 78 66 36 36 50 70 94 94 80 42 40 58 80 108 108 92 48 46 66 90 124 124 104 NOTES: A. ALL FLANGE HARDWARE (BOLT/WASHER/NUT) SHALL BE STAINLESS STEEL -TYPE 304 WITH ANTI -SEIZE COMPOUND. B. ALL PIPE SHALL BE RESTRAINED JOINT DUCTILE IRON FROM TAP TO PROPERTY LINE VALVE. C. METER CONFIGURATION AND LENGTH MAY VARY DUE TO BRAND - VERIFY LENGTH TO DETERMINE MINIMUM VAULT LENGTH. D. VAULT SHALL BE SIZED AS NEEDED FOR PIPE (7.5'x4' MINIMUM) AND RATED FOR NCDOT HS-20 LOADING -SUBMIT SHOP DRAWINGS / P.E. SEALED FOR REVIEW. E. ALL CONCRETE SHALL BE MINIMUM 4000 PSI COMPRESSIVE STRENGTH F. DESIGN SHALL CONFORM TO ASTM C858 -SPECIFICATIONS FOR "UNDERGROUND PRECAST CONCRETE UTILITY STRUCTURE" f 5'-0" (MIN.) 1 G. STEEL REINFORCING DESIGN SHALL CONFORM TO ASTM C857 H. REBARS SHALL BE GRADE 60 PER ASTM A615 I. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 J. DIAGONAL REINFORCING SHALL BE ADDED AT ALL OPENINGS K. PIPE PENETRATIONS SHALL BE SEALED WITH FLEXIBLE CONNECTORS (MANHOLE BOOTS) OR WITH 8-INCHES OF BRICK &MORTAR (AND 1/2 INCH THICK CONSTRUCTION EXPANSION MATERIAL) L. FRAME TO BE FLUSH WITH GROUND OR CONCRETE SIDEWALK, GROUND SHALL SLOPE AWAY FROM VAULT. M. ALL JOINTS SHALL BE MADE WATERTIGHT USING 2 RINGS OF BUTYL RUBBER JOINT MASTIC. N. ALL VALVES SHALL BE OPEN RIGHT -CLOCKWISE, EXCEPT NO. O3 LL ) EWALK NO. DESCRIPTION 1 4" TAPPING SLEEVE AND 4" FLANGE x MJ TAPPING VALVE ON EXISTING MAIN. 3" MJ TEE AND 3" MJ GATE VALVE ON NEW MAIN. 2 STANDARD VALVE BOX ASSEMBLY (TYP.) -ALL VALVES 3 4" x 3" REDUCER (RJ) REQUIRED ON EXISTING MAIN INSTALLATIONS. (REDUCER NOT REQUIRED ON NEW MAIN INSTALLATIONS) 4 FLANGE DUCTILE IRON TEE WITH ADJUSTABLE FLANGE SUPPORT 5 FLANGE DUCTILE IRON 90'-BEND 6 FLANGE x PLAIN END DUCTILE IRON PIPE (MIN. SPECIAL CLASS 53) 7 MJ LONG PATTERN SOLID SLEEVE WITH RESTRAINED JOINTS 8 3/4" BALL CORPORATION STOP WITH TAPPING SADDLE 9 FLANGE GATE VALVE; WITH 2" OPERATING NUT -OPEN RIGHT AND WITH ADJUSTABLE FLANGE SUPPORT ON BYPASS VALVE 10 FLANGE STRAINER 11 FLANGE COMPOUND METER ASSEMBLY W/AMR TRANSMITTERS. METER CONFIGURATION MAY VARY DUE TO BRAND SUPPLIED. 12 FLANGE CHECK VALVE W/BLIND FLANGE-2" TAP/THREADED BRASS PLUG 13 MECHANICAL JOINT (RJ) GATE VALVE-2" OPERATING NUT -OPEN LEFT @ PROPERTY LINE. 14 MECHANICAL JOINT PLUG WITH 2" TAP 15 2" PIPE GALVANIZED STEEL (SCH 80), RED BRASS (SCH 40), HDPE (DR 9) OR DIP WITH STANDARD VALVE BOX/CONCRETE PAD 16 2" THREADED COUPLING 17 ADJUSTABLE FLANGE SUPPORTS (3 REQUIRED) 18 AMR TRANSMITTERS 19 4' x 5' DOUBLE -LEAF ACCESS DOOR. SEE STANDARD DETAIL. 20 PRECAST REINFORCED CONCRETE VAULT 21 MINIMUM OF (3) STANDARD SOLID CONCRETE BRICK COURSES UNDER ACCESS DOOR FRAME, MAXIMUM 2FT. 22 JOINT REQUIRED AT FLAT TOP SECTION. 23 3/8" DIA. GALV. STEEL EYE BOLT (ADHESIVE ANCHOR) -TYPICAL 24 AWG #12 GAUGE COPPER TRACER WIRE (THWN) -WITH BLUE INSULATION - TERMINATE WITH 24" EXCESS WIRE (COILED) @EYE BOLT AND VALVE BOX (TYPICAL). 25 CAST IN PLACE CONCRETE SIDEWALK -BRICKWORK SHALL NOT EXTEND TO SURFACE. ACCESS DOOR FRAME SHALL REST ON SIDEWALK. 26 VALVE LOCK (FURNISHED BY CMUD) -LOCK VALVE CLOSED 27 PLASTIC STEP - 12" OR 16" O.C. VERTICAL SPACING Kel 000 k )27 SECTION VIEW a 00 W J Z Q 0 > o U)o w 0 z a Z'� °� w 0 Q W J W W F--- Q z 0 O �U O� OW L � U M 5' MIN. SEE NOTE F & G SEE NOTE F & G SHUT-OFF VALVE #1 SEE NOTE #2 TEST COCK #1 RESTRAINED JOINT SEE NOTE #3 HINGED ACCESS OR REMOVABLE INSULATED ENCLOSURE MEETING ASSE 1060 SPECIFICATIONS. ENCLOSURE TO INCLUDE DRAIN PORT(S) PER CLT WATER REQUIREMENT. SUPPORTS SEE NOTE #4 SLOPE GROUND AWAY FROM _ a COVER I —III SLEEVE REQUIRE (TYP.) RESTRAINED JOINT SEE NOTE #3 FIRE SERVICE SIZE SECTION VIEW a 00 W J Z Q 0 > o U)o w 0 z a Z'� °� w 0 Q W J W W F--- Q z 0 O �U O� OW L � U M 5' MIN. SEE NOTE F & G SEE NOTE F & G SHUT-OFF VALVE #1 SEE NOTE #2 TEST COCK #1 RESTRAINED JOINT SEE NOTE #3 HINGED ACCESS OR REMOVABLE INSULATED ENCLOSURE MEETING ASSE 1060 SPECIFICATIONS. ENCLOSURE TO INCLUDE DRAIN PORT(S) PER CLT WATER REQUIREMENT. SUPPORTS SEE NOTE #4 SLOPE GROUND AWAY FROM _ a COVER I —III SLEEVE REQUIRE (TYP.) RESTRAINED JOINT SEE NOTE #3 FIRE SERVICE SIZE DETECTOR METER SIZE 4" 1" 6" 1" 8" 1" 10" 1" NOTES: A. ALL FLANGE HARDWARE (BOLT/WASHER/NUT) SHALL BE STAINLESS STEEL -TYPE 304 WITH ANTI -SEIZE COMPOUND. B. ALL PIPE SHALL BE RESTRAINED JOINT DUCTILE IRON FROM TAP TO PROPERTY LINE VALVE. C. METER BOX TO BE FLUSH WITH GROUND OR CONCRETE SIDEWALK, GROUND SHALL SLOPE AWAY FROM METER BOX. D. ALL VALVES SHALL BE OPEN RIGHT -CLOCKWISE, EXCEPT NO. 70. E. ONE INCH METER SHALL BE INSTALLED IN STANDARD CONCRETE METER BOX PER STD. DETAIL. F. WRAP TAPPING SLEEVE WITH 2 LAYERS HDPE PLASTIC FILM (HDCLPE PER AWWA C-105) - 4 MILS EACH LAYER -EXTEND HDPE 2 FT. EACH WAY FROM SLEEVE -DUCT TAPE OR ZIP LOCK TIE ENDS. G. CONCRETE THRUST BLOCKING REQUIRED AT TAPPING SLEEVE. H. ANGLE BALL VALVE 11 PERMANENT LOCK (WITH CMU SERIAL #) SHALL BE FURNISHED BY CMU. TYPICAL PLAN TYPICAL ELEVATION REDUCED PRESSURE PRINCIPLE ASSEMBLY CHECK VALVE #1 CHECK VALVE #2 � b t� FLOW— :11 ® RELIEF VALVE 12" MIN. 30" MAX. OUTLET a FL' NO. DESCRIPTION w C) o 0 1 TAPPING SLEEVE & FL x MJ TAPPING VALVE ON EXISTING MAIN. J 0 z N ° MJ TEE AND MJ GATE VALVE ON NEW MAIN Q o w No 2 STANDARD VALVE BOX ASSEMBLY (TYP) -ALL VALVES � o �--� 3 RESTRAINED JOINT DUCTILE IRON PIPE 0 Q o 4 FLANGE x MJ GATE VALVE ON LONG SIDE SERVICES. FLANGE x FL Z m o ADAPTER ON SHORT SIDE SERVICE (NOT SHOWN) 5 DETECTOR CHECK VALVE (FLANGE x FLANGE) 6 FLANGE x MJ ADAPTOR (OMIT WHEN PROPERTY LINE VALVE 7�IS BOLTED DIRECTLY TO DETECTOR CHECK VALVE 5O) 7 MJ GATE VALVE (RESTRAINED, OPEN LEFT) AT PROPERTY LINE. (FL x I MJ GATE VALVE BOLTED DIRECTLY TO DETECTOR CHECK VALVE O- WHEN APPROVED) � J 8 2" PIPE GALV. STEEL (SCH 80), RED BRASS (SCH 40), HDPE (DR 9), OR MM DUCTILE IRON PIPE, WITH THREADED COUPLING. � W 9 CTS x MNPT BRASS STRAIGHT COUPLING (WITH BRASS HEX W REDUCING BUSHING - AS REQUIRED) w U 10 1" COPPER TUBE - TYPE K OR HDPE (PLOY TUBING) SDR 9 '^ ��J/J� 11 1"ANGLE BALL VALVE WITH LOCK WINGS (LOCK OPEN)(CTS ' vi COMPRESSION x YOKE STAR NUT) !' 12 13 1" METER YOKE BAR 1" SINGLE ANGLE CHECK VALVE (YOKE STAR NUT x CTS COMPRESSION) W 14 1"METER ASSEMBLY WITH AMR ERT TRANSMITTER (BY CMU) ��/ UJ SIDE ELEVATION NOTES: 1. BACKFLOW PREVENTION ASSEMBLIES (BPA's) SHALL CONFORM TO CLT WATER SPECIFICATIONS. SHUT-OFF VALVES ARE SPECIFIC TO EACH APPROVED BPA AND NO SUBSTITUTIONS OF SHUT-OFF VALVES ARE PERMITTED. REFER TO CLT WATER APPROVED LIST OF BPA's. 2. FIRE LINE SERVICES SHALL HAVE OUTSIDE STEM AND YOKE (OS & Y) HANDWHEEL OPERATORS OR BUTTERFLY VALVES, AND LISTED ON APPROVED LIST AS FIRE APPROVED. IF SERVING FIRE SPRINKLERS, TAMPER SWITCHES ARE REQUIRED. 3. PIPE MATERIAL AND FITTINGS SHALL BE AS SPECIFIED IN CLT WATER STANDARDS SPECIFICATION. ALL JOINTS SHALL BE RESTRAINED WITH MEGALUG RESTRAINTS OR APPROVED EQUAL. 4. SUPPORT OF ASSEMBLY SHALL BE DESIGNED BY OWNER, 8" - 12" SHALL SHUT-OFF VALVE #2 BE SUPPORTED AT EACH VALVE AND SHALL NOT BLOCK RELIEF VALVE SEE NOTE #2 ON DRAIN PORT. COVER MUST NOT 5. INSULATED ENCLOSURE SHALL BE AS SPECIFIED IN CLT WATER ENCLOSURE OBSTRUCT VALVE INFORMATION -HEATED INSULATED ENCLOSURE ARE REQUIRED FOR IT BEING FULLY FIRE LINE SERVICES. NO INSULATION SHALL BE WRAPPED AROUND BPA. } OPENED 6. ALL LOCATIONS FOR BPA'S REQUIRE CLT WATER APPROVAL AND MUST BE OUTSIDE OF ZONING SET -BACK DIRECTLY BEHIND METER. 7. THERE SHALL BE NO TAPS, PIPING BRANCHES, UNAPPROVED BYPASS PIPING, HYDRANTS, FIRE DEPT. CONNECTION POINTS, OR OTHER WATER -USING APPURTENANCES CONNECTED TO THE SUPPLY LINE BETWEEN ANY WATER METER AND ITS SUPPORTS CLT WATER -REQUIRED BACKFLOW PREVENTER. SEE NOTE #4 g. EACH CLT WATER -REQUIRED BPA IS REQUIRED TO BE TESTED BY A CLT WATER -APPROVED CERTIFIED TESTER PRIOR TO PLACING THE WATER SYSTEM IN SERVICE. TEST RESULTS SHALL BE SUBMITTED TO CLT WATER WITHIN 30 DAYS AND TESTED ANNUALLY THEREAFTER SUBMITTING DUCTILE IRON PIPE OR RESULTS TO CLT WATER. TYPE K OR L COPPER TUBING FOR MIN. OF 5' 9. ALL INSTALLATIONS INTENDED FOR ADDRESSING CLT WATER ON EACH END OF ASSEMBLY. REQUIREMENTS, REQUIRE PRIOR APPROVAL FROM THE APPROPRIATE CLT SEE NOTE #3 WATER BACKFLOW INSPECTOR. I III 1I I LOWEST POINT OR SLEEVE REQUIRED RELIEF VALVE OUTLET (TYP.) SUPPORT, PAD AND CONCRETE FOOTINGS AS REQUIRED BY SYSTEM DESIGNER ZONING I SETBACK — — MIN. 4" THICK CONCRETE PAD — REQUIRED PROPERTY- - LINE PUBLIC '• 3: WATER 6� MAIN 0 Q 0 - CLT WATER REQUIRED BPA ABOVEGROUND SEE NOTE #6 & #7 - CLT WATER METER TYPICAL LOCATION REQUIREMENT FOR ABOVE GROUND INSTALLATION N.T.S. CLLJ ) w � a 0 W O p N J Z w M Q o > `rS Q (V O z o Z N o ry w 0 W � W Z O m W Q (n N W � N J 5m Q W U)z Q � 3 W W p w W � a 0 0 0 Z LL Y _ � Q U W m w H � W = Q U 5 URBAN DESIGN PARTNERS 1318-e6 central ave. I= 704.334.3303 charlotte, nc 28205 F 704.334.3305 urbandesignpartners.com nc firm no: P-0418 sc coa no: C-03044 L = 90 - 09/30/2020 ^L W U rl_ J � o °N° J � O N z �i N m p V n Project No: 19-133 Date: 09.30.2020 Designed by: UDP Drawn By: UDP Sheet No: C-8m3 STEEL POST WIRE FENCING (IF APPLICABLE) WOVEN FILTER FABRIC I 4' MAX. ■■■IIII .• • r • • • • • 11I■■■ �■■'ll !ME] MEN�;pyp, i ,yaws • y SS R� F5".8 R� R� ::F�i6 R- n0•p0-104P ee.� ; **4 .F'S^.g .y a NO` tl@[ Ew5 8�8 8 .. .6 £ fit!- 8� E:S�iid • i .����i 'M '':!sm�• ...n.�... �. '�'•:�SCem�• �e v=•n�. �w�•�r iir' e r • �i STEEL POST HARDWARE CLOTH WASHED STONE (NCDOT #5 OR #57) i FLOW ANCHOR SKIRT; EXCAVATE TRENCH AND COMPACT BACKFILL WOVEN FILTER FABRIC 0 N 6' MAX. STEEL POST z � FILTER FABRIC �w J U o N a FLOW g�0' n I 4 ANCHOR SKIRT; EXCAVATE TRENCH AND COMPACT BACKFILL GENERAL NOTES: 1. WOVEN FILTER FABRIC BE USED WHERE SILT FENCE IS TO REMAIN FOR A PERIOD OF MORE THAN 30 DAYS. 2. STEEL POSTS SHALL BE 5-0" IN HEIGHT AND BE OF THE SELF -FASTENER ANGLE STEEL GENERAL NOTES: MAINTENANCE NOTES: TYPE. MAINTENANCE NOTES: 1. SEDIMENT FILTER OUTLET AND HARDWARE CLOTH SHALL BE 16 INCHES HIGH BUT NO 1. FILTER OUTLETS SHALL BE BY THE FINANCIALLY RESPONSIBLE PARTY OR INSPECTED 3. TURN SILT FENCE UP SLOPE AT ENDS. 1. FILTER BARRIERS SHALL BE INSPECTED BY THE FINANCIALLY RESPONSIBLE PARTY TALLER THAN 18 INCHES. HIS AGENT IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING OR HIS AGENT IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS NEEDED SHALL BE MADE IMMEDIATELY. 4. ORANGE SAFETY FENCE IS REQUIRED AT BACK OF SILT FENCE WHEN GRADING IS PROLONGED RAINFALL. ANY REPAIRS NEEDED SHALL BE MADE IMMEDIATELY. 2. HARDWARE CLOTH SHALL BE ANCHORED TO THE STEEL POSTS SECURELY USING ADJACENT TO SWIM BUFFERS, STREAMS OR WETLANDS (REFER TO SWIM BUFFER APPROPRIATE ANCHORS. HARDWARE CLOTH SHALL BE KEYED IN A MINIMUM OF 12 INCHES 2. THE STONE SHALL BE REPLACED PROMPTLY AFTER ANY EVENT THAT HAS CLOGGED GUIDELINES). THE COLOR ORANGE IS RESERVED FOR VISUAL IDENTIFICATION OF 2. SHOULD THE FABRIC DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END IN LENGTH AND BACKFILLED PROPERLY AS SHOWN IN ABOVE DETAIL. HARDWARE CLOTH TO OR REMOVED IT. ENVIRONMENTALLY SENSITIVE AREAS. OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL IS NECESSARY, THE BE SAME AS STD. #30.09 (19 GAUGE, 1/4" SPACING). 3. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN DEPOSITS REACH HALF THE HEIGHT FABRIC SHALL BE REPLACED PROMPTLY. 3. POSTS SHALL BE NO MORE THAN 4 FEET APART. OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT 5. 4 ACRE PER 100 FT OF FENCE. DRAINAGE AREA CAN NOT BE GREATER THAN 1/4 FENCE OUTLET IS REMOVED SHALL BE DRESSED TO CONFORM TO THE EXISTING 3. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN DEPOSITS REACH APPROX. HALF 4. SITE OUTLETS AT ANY POINT SMALL CONCENTRATED FLOWS ARE ANTICIPATED AND AT THE GRADE, PREPARED AND SEEDED. 6. SLOPE LENGTHS CAN NOT EXCEED CRITERIA SHOWN IN TABLE 6.62A NORTH CAROLINA THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE DIRECTION OF THE INSPECTOR. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. AFTER THE SILT FENCE IS REMOVED SHALL BE DRESSED TO CONFORM TO THE EXISTING GRADE, PREPARED AND SEEDED. 7. DO NOT INSTALL SEDIMENT FENCE ACROSS STREAMS, DITCHES, WATERWAYS OR OTHER AREAS OF CONCENTRATED FLOW. • CITY OF CHARLOTTE LAND DEVELOPMENT STANDARDS CHARLOTTE- INCLUDES CHARLOTTE ETJ NOT TO SCALE NOT TO SCALE SILT FENCE CITY OF CHARLOTTE STD. NO. REV. LAND DEVELOPMENT STANDARDS TEMPORARY SILT FENCE STD. NO. REV. OUTLET 130.06C 1 5 rTE- INCLUDES CHARLOTTE ETJ 30.06A 15, 0 0 0 GENERAL NOTES: 1. SEDIMENT SHALL BE REMOVED AND TRAP RESTORED TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO 1/2 THE DESIGN DEPTH OF THE TRAP. 2. REMOVED SEDIMENT SHALL BE DEPOSITED IN A SUITABLE AREA AND IN SUCH A MANNER THAT IT WILL NOT ERODE. 3. THE STRUCTURE SHALL BE INSPECTED BY THE FINANCIALLY RESPONSIBLE PARTY OR HIS AGENT AFTER EACH STORM EVENT AND REPAIRS MADE AS NECESSARY. 4. CONSTRUCTION OPERATIONS SHALL BE CARRIED OUT IN SUCH A MANNER THAT EROSION AND WATER POLLUTION ARE MINIMIZED. 5. THE SEDIMENT TRAP SHALL BE REMOVED AND THE AREA STABILIZED WHEN THE DRAINAGE BASIN HAS BEEN PROPERLY STABILIZED. 6. ON LARGER DRAINAGE AREAS RIP RAP MAY BE REQUIRED UNDER THE WASHED STONE. • CITY OF CHARLOTTE LAND DEVELOPMENT STANDARDS CHARLOTTE- INCLUDES CHARLOTTE ETJ SECTION • CITY OF CHARLOTTE h LAND DEVELOPMENT STANDARDS CHARLOTTE. INCLUDES CHARLOTTE ETJ 0 STE" ^^ WIRE FENCING WOVEN FILTER FABRIC 0 N GENERAL NOTES: 1. WIRE FENCING SHALL BE A MINIMUM OF 32" IN WIDTH AND SHALL HAVE A MINIMUM OF 6 LINE WIRES WITH 12" STAY SPACING. 2. WOVEN FILTER FABRIC BE USED WHERE SILT FENCE IS TO REMAIN FOR A PERIOD OF MORE THAN 30 DAYS. 3. STEEL POSTS SHALL BE 5'-0" IN HEIGHT AND BE OF THE SELF -FASTENER ANGLE STEEL TYPE. 4. WIRE FENCING SHALL BE AT LEAST #10 GAGE WITH A MINIMUM OF 6 LINE WIRES WITH 6" STAY SPACING. 5. TURN SILT FENCE UP SLOPE AT ENDS. 6. WIRE AND WASHED STONE IS REQUIRED TO BE SHOWN ON PLANS AT THE TOE OF SLOPES GREATER THAN 10 FEET VERTICAL (2:1 SLOPE) 7. ORANGE SAFETY FENCE IS REQUIRED AT BACK OF SILT FENCE WHEN GRADING IS ADJACENT TO SWIM BUFFERS STREAMS OR WETLANDS REFER TO SWIM BUFFER GUIDELINES). THE COLOR ORANGE IS RESERVED FOR VISUAL IDENTIFICATION OF ENVIRONMENTALLY SENSITIVE AREAS. 8. DRAINAGE AREA CAN NOT BE GREATER THAN 1/4 ACRE PER 100 FT OF FENCE. 9. SLOPE LENGTHS CAN NOT EXCEED CRITERIA SHOWN IN TABLE 6.62A NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. 10.DO NOT INSTALL SEDIMENT FENCE ACROSS STREAMS, DITCHES, WATERWAYS OR OTHER AREAS OF CONCENTRATED FLOW. • CITY OF CHARLOTTE LAND DEVELOPMENT STANDARDS CHARLOTTE. INCLUDES CHARLOTTE ETJ 8' MAX. STEEL POST rF" IRE FENCING Z LTER FABRIC 0 w c�5 OR 57 WASHED STONE M J , v m FLOW `'\ -fie 8 4" ANCHOR SKIRT; EXCAVATE TRENCH AND COMPACT BACKFILL MAINTENANCE NOTES: 1. FILTER BARRIERS SHALL BE INSPECTED BY THE FINANCIALLY RESPONSIBLE PARTY OR HIS AGENT IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS NEEDED SHALL BE MADE IMMEDIATELY. 2. SHOULD THE FABRIC DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL IS NECESSARY THE FABRIC SHALL BE REPLACED PROMPTLY. 3. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN DEPOSITS REACH HALF THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE IS REMOVED SHALL BE DRESSED TO CONFORM TO THE EXISTING GRADE, PREPARED AND SEEDED. NOT TO SCALE HIGH HAZARD TEMPORARY SILT FENCE STD. N0 REV 30.06B 15 NOTES: 1 / 1. A STABILIZED ENTRANCE PAD OF 2-3" OF WASHED STONE AND/OR RAILROAD BALLAST SHALL BE LOCATED WHERE TRAFFIC WILL ENTER OR LEAVE THE CONSTRUCTION SITE ONTO \ � / A PUBLIC STREET. <'O 2. FILTER FABRIC OR COMPACTED CRUSHER RUN STONE SHALL BE USED AS A BASE FOR THE CONSTRUCTION ENTRANCE. 3. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC STREETS OR EXISTING PAVEMENT. THIS MAY #5 WASHED STONE REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONS WARRANT AND REPAIR OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. 4. ANY SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO PUBLIC STREETS MUST BE REMOVED IMMEDIATELY. ANY AGGREGATE TRACKED INTO THE ROADWAY MUST BE SWEPT BACK ONSITE ON A NIGHTLY BASIS. W. ol q\ STORAGE 5. WHEN APPROPRIATE, WHEELS MUST BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTERING A PUBLIC STREET. WHEN WASHING IS REQUIRED, IT SHALL BE DONE IN AN AREA AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT BASIN SEE STD. NO. 30.11B. M. lo o o 6. CDOT MAY REQUIRE A STANDARD COMMERCIAL DRIVEWAY (STD. 10.24 & 10.25) TO ACCESS THE CONSTRUCTION SITE IF THE DRIVEWAY IS ON A THOROUGHFARE, OR ON ANY STREET WITH AN EXISTING SIDEWALK TO REMAIN OPEN DURING CONSTRUCTION. 0 0 7. FOLLOW WORK AREA TRAFFIC CONTROL HANDBOOK (WATCH) FOR SIDEWALK CLOSURE OR DETOUR/DIVERSION. STORAGE AREA o o CATCH BASIN 00' MIN. i PUBLIC STREET J III III III III III Ili EXISTING GROUND II SOIL STABILIZATION FABRIC II UNDER 2-3" OF WASHED STONE PLAN VIEW / 1 100' MIN. EX. CONY. DRIVEWAY APRON I WITH SIDEWALK AT BACK OF CURB (IF RETAINED DURING w CONSTRUCTION.) z # WASHED Q STONEQ D' w z w FS\_ - O Q Fj V) 12" MIN. 00 1f 31 I�III_I'LIIdi '-'J CATCH BASIN IIIEI m ATE m '11 .3 -4 WIIIWI � m SECTION A-AE NOT TO SCALE NOT TO SCALE • CITY OF CHARLOTTE STONE INLET PROTECTION ­STD.NO REV. LAND DEVELOPMENT STANDARDS S TA B O Z E D CONSTRUCTION ENTRANCE STD NO. REV. 30.08 CHARLOTTE- INCLUDES CHARLOTTE ETJ 30.1 1 A 115, NOTES: 1. INLET MAINTENANCE SHALL BE DOCUMENTED IN PROJECT LOG BOOK. 2. FILTER TYPES SHALL BE APPROVED BY THE CITY INSPECTOR PRIOR TO INSTALLATION. 3. FILTER BAGS MAY BE REMOVED WHEN SITE IS STABILIZED AT THE DIRECTION OF THE ENGINEER. 4. FILTER BAGS SHALL BE REMOVED PRIOR TO STREET ACCEPTANCE AND/OR CLOSE OUT OF GRADING PERMIT. 5. FILTER BAGS SHALL BE CLEANED OR REPLACED ON A REGULAR BASIS (NOT BE MORE THAN HALF FULL AT ANY TIME). 6. FILTER BAGS MAY BE INSTALLED IN EXISTING CITY OR NCDOT ROADS AS LONG AS STORM DRAINAGE IS NOT IMPEDED. GRATE 1" REBAR FOR BAG REMOVAL FROM INLET ®, FILTER DUMP L( CATCH BASIN INSTALLATION DEFLECTOR REQUIRED WHEN USED ON EXISTING MAINTAINED STREETS. DEFLECTOR SHALL BE PLACED SUCH THAT IT WILL NOT COMPLETELY OBSTRUCT STORM WATER FLOW FROM ENTERING VIA THE CURB OPENING. ENSURE NO MORE THAN 25% OF CURB OPENING IS OBSTRUCTED. DUTLET NOT TO SCALE CATCH BASIN INLET PROTECTION STD. NO. REV. 30.15 13, 0 0 SEE APPROVED PRESERVATION F REQUIRED RADIU OF TREE BARRIE PLAN VIEW OF ROOT ZONE ONE FOC INCH OF OR 1/2 FOR PRUNING SEE WHICHEVI INTERNATIONAL SOCIETY OF ARBORICULTURE SPECS. DEAD TREES AND SCRUB OR UI GROWTH SHALL BE CUT FLUSH ADJACENT GRADE. NO GRUBBIN ALLOWED UNDER DRIP LINE. 2"x4" STANDARDS + V'0" RAILS OR ORANGE SAFETY FENCING MAY BE USED. • CITY OF CHARLOTTE h LAND DEVELOPMENT STANDARDS CHARLOTTE. INCLUDES CHARLOTTE ETJ NOTES: 1. REMOVE ALL BARRIERS UPON COMPLETION OF PROJECT. 2. LANDSCAPING PLANS SHALL SHOW THE LOCATIONS OF ALL TREE PROTECTION FENCES. 3. REFER TO CITY OF CHARLOTTE LANDSCAPE CONSTRUCTION STANDARDS SECTION 01000 FOR GENERAL SPECIFICATION REGARDING TREE PROTECTION. TREE PROTECTION DETAIL RK MULCH, PLACE BARK i AT AREAS NOT CTED BY BARRIER. NOT TO SCALE 40.02 0 U RBAN DESIGN PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 R 704.334.3305 u rbandesign partners. com nc firm no: P-0418 sc coa no: C-03044 U U 0 j N J o00 C\l J z O (1) c� .� Q) L m p O M 00 S.- U = 0-) 0 LO • r 4-1 W c QN 00 N O Z O OCz 0 Cz U a� 00 OCO T N W r z U) W rr m W Q b Z Project No: 19-133 Date: 09.30.2020 Designed by: UDP Drawn By: UDP Sheet No: C-804 ANNA MILL PID # 0810 BLOCK 4 SEC MB 151 ZONED: R USE: SINGLE l RESIDENTI 7 ERIN T THOMAS AND SCOTT BOULET PID # 08709910 BLOCK 4 SECTION 2 MB 751-43 ZONED: R-5 USE: SINGLE FAMILY RESIDENTIAL I n I � � I MILDRED M DIAGO%N0. _ — L ELLORENZO DIAGO w Z PID # 08109911 BLOCK 4 SECTION 2 MB 151-43 ZONED:R-5 USE. SINGLE FAMILY RESIDENTIAL ti I I z R-5 ZONING B— i ZONING ALLTIME FACTORS, INC PID #: 08109912 BLOCK 4 SECTION 2 MB 151-43 ZONED: B-1 USE: COMMERCIAL II EXIST. WALL TO PROVIDE SCREENING FROM ADJACENT PROPERTY SIDEWALK & UTILIT (DB — — W — — — — THOMAS FII RnnNF ANn I I\V1 . J I I\LL I 11\LL 1 V lvin I1 l I 1 SEIGLE AVENUE EXIST. ELMS ON SEIGLE AVENUE 1 50' PUBLIC R/W 1 1 CDOT MAINTAINED 25 MPH SPEED LIMIT 1 ti I ii ! PLANT LEGEND TREES CODE BOTANICAL / COMMON NAME of 61D LSR LIQUIDAMBAR STYRACIFLUA'ROTUNDILOBA' TM / ROUND -LOBED SWEET GUM URBAN QBB QUERCUS BICOLOR BONNIE AND MIKE TM / BEACON OAK D E S I G N QRU QUERCUS RUBRA / RED OAK PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc F 704.334.3305 UPA ULMUS PARVIFOLIA 'ALLEE' / ALLEE LACEBARK ELM urbandesignpartnertners.com nc firm no: P-0418 sc coa no: C-03044 SHRUBS CODE BOTANICAL / COMMON NAME LCR LOROPETALUM CHINENSE RUBY' / RUBY LOROPETALUM 000(J00000000000 000000� N °CAIQO SING LANDSCAPE REQUIREMENTS: �i ---- BUFFERS AND SCREENING: ALL PARKING SPACES, DUMPSTERS, AND RECYCLING CONTAINERS MUST BE SCREENED FROM PUBLIC RIGHTS OF WAY AND ADJACENT PROPERTIES. ALL METER BANKS AND HVAC RELATED MECHANICAL EQUIPMENT WILL BE SCREENED FROM E. 15TH STREET, SEIGLE AVE AND ADJACENT PROPERTIES. 09/30/2020 INTERNAL TREES: ALL NEW PARKING SPACES MUST BE WITHIN 40 FEET OF THE TRUNK OF A TREE. ONE TREE REQUIRED PER 10,000 SF OF IMPERVIOUS AREA. TOTAL IMP. AREA = 17,248 SF/10,000 SF = 1.7 = 2 TREES REQUIRED i 2 PROPOSED TREES PROVIDED* *EXISTING TREES IN REAR AND SIDE YARDS TO COUNT TOWARD INTERNAL TREE REQUIREMENT V ~O U > N PERIMETER (STREET) TREES: J C) � U 1 LARGE TREE ON 40 FOOT CENTERS OR 1 SMALL TREE ON 30 FOOT CENTERS WHERE THERE ARE 0 � z OVERHEAD UTILITIES. LO E. 15TH ST: 150 LF / 40 = 3.75 = 4 LARGE MATURING TREES REQ'D = .i 00 p 4 PROP. TREES PROVIDED (3 IN LANDSCAPE STRIP & 1 IN REAR YARD)*** O M SEIGLE AVE: 150 LF / 40 = 3.75 = 4 LARGE MATURING TREES REQ'D** _ U 2 EXISTING ELM TREES TO REMAIN 2 PROP. TREE PROVIDED (1 IN LANDSCAPE STRIP & 1 IN REAR YARD)*** ***DUE TO DRIVEWAY WIDTH AND LOCATION OF UTILITIES AND SIDEWALK, IT IS NOT POSSIBLE TO PROVIDE THE REQUIRED TOTAL OF TREES ALONG THE STREET FRONTAGE. 2 REMAINING REQUIRED TREES ARE LOCATED WITHIN THE SITE. m CPCOMMERCIAL TREE SAVE AREA: 7`0 -T IN URBAN ZONES LOCATED IN WEDGE AREAS, A MINIMUM OF 15% OF THE OVERALL COMMERCIAL SITE MUST Cl) BE PRESERVED AS TREE SAVE AREA. FOR ANY TREE SAVE AREA NOT PRESERVED THE FOLLOWING A MEASURES MAY BE CHOSEN, INDIVIDUALLY OR IN COMBINATION, SUCH THAT THE MEASURES ARE EQUAL TO Do 150 PERCENT OF ANY PORTION OF THE COMMERCIAL TREE SAVE AREA NOT PRESERVED AS REQUIRED m ABOVE. A. PLANT OR REPLANT TREES AT A RATE OF 36 TREES PER ACRE ON -SITE. B. PROVIDE -I AMENITIZED TREE AREA THAT MEETS THE FOLLOWING: 1. TREES MUST BE PLANTED AT 36 TREES PER ACRE ON -SITE. 2. PLANTING AREAS SHALL BE A MINIMUM OF 10 FEET WIDE. ' 3. NO MORE THAN 25% OF IMPERVIOUS PAVED AREAS WITHIN THE AMENITIZED TREE AREA WILL BE ALLOWED. GRAVEL PATHWAYS IN AMENITIZED TREE AREAS WILL BE CONSIDERED PERVIOUS. ,1 4. TREES MAY BE PLANTED IN ALTERNATIVE LOCATIONS, SUCH AS BUT NOT LIMITED TO ROOFTOPS, -r' PERMANENT PLANTERS, RAISED OR AT GRADE PLAZAS, OVER PARKING DECKS, OR OTHER LOCATIONS LO APPROVED BY THE CITY. PLANTING IN ALTERNATIVE LOCATIONS SHALL BE PER THE LAND DEVELOPMENT STANDARDS MANUAL OR AS APPROVED BY THE CITY. 5. AMENITIES MAY INCLUDE, BUT ARE NOT LIMITED TO IRRIGATION, LANDSCAPING, GRASS, SEATING, LO I PATHWAYS AND LIGHTING OR OTHER ITEMS, AS APPROVED BY THE CITY. C) I NO STRUCTURE WILL BE ALLOWED WITHIN TEN FEET OF THE TREE SAVE AREA. A BUILDING RESTRICTION 00 MUST BE NOTED ON THE RECORD PLAT IN ACCORDANCE WITH THE TREE ORDINANCE GUIDELINES. FOR N URBAN ZONES THE TEN -FOOT BUILDING RESTRICTION MAY BE COUNTED TOWARD THE TREE SAVE AREA U REQUIREMENT AS LONG AS THIS AREA 11 CONTINUOUSLY AND DIRECTLY ABUTS A TREE SAVE AREA, AND (y j z REMAINS PERVIOUS. HOWEVER, REGULATORY TREES MAY NOT BE PLANTED WITHIN THIS TEN -FOOT AREA. TOTAL SITE AREA = 22,553 SF = (.0.52 AC) X 15% = 3,383 SF (.08 AC) TREE SAVE AREA REQUIRED 0 995 SF (0.02) AC TREE SAVE AREA PROTECTED W 2,388 SF (0.06 AC)*(150%) = 3,582 SF (0.08) AC REPLANTED TREE SAVE REQUIRED 0_0 3,585 SF (0.08) AC REPLANTED TREE SAVE AREA PROVIDED 6 0. TREES PER ACRE REQUIRED ♦ 1 Q 0.08 AC*(36 TREES) = 2.88 TREES = 3 TREES REQUIRED V 3 TREES PROVIDED Cn XXX PLANT CODE N xx PLANT QUANTITY NOTES: m MELT � IF GRAPHIC REPRESENTATION OF PLANTINGS ON PLANS DO NOT MATCH QUANTITIES IN PLANT SCHEDULE, GRAPHIC REPRESENTATION OF PLANTINGS WILL GOVERN. TREES NOT IN A LANDSCAPE BED SHALL RECEIVE A 4' DIAMETER MULCH RING. I N FULL LANDSCAPE SCHEDULE ON SHEET LS-2.0 CITY TREE PLANTING AND PRESERVATION NOTES ON SHEET LS-2.0 z O Ln w Ir m Q ohL O� O z BEFORE YOU DIOI S i CALL 8" OR 1-800-632-4949 Project No: 19-133 N.C. ONE —CALL CENTER N I IT'S THE LAWI Date: 09.30.2020 I I I Designed by: UDP 17111 Drawn By: UDP ' I I I N Sheet No: I I GRAPHIC SCALE 10 0 5 10 20 LS-1 0 1 INCH = 10 FEET ■ 1. REMOVE WIRE AND NYLON TWINE FROM BALL AND CANOPY. 2. SOAK ROOT BALL AND PLANT PIT IMMEDIATELY AFTER INSTALLATION. 3. STAKING IS REQUIRED FOR ALL TREES IN R.O.W. OR UPON REQUEST OF ARBORIST. 4. REMOVE EXCESS SOIL FROM SITE AND DISPOSE OF IN A LEGAL MANNER. 5. RESEED UNMULCHED, DISTURBED AREAS. 3/4" NYLON STRAP - ROOT CROWN TO BE AT FINISH GRADE 4" HIGH / 6" WIDE MAXIMUM BERM OUTSIDE OF ROOTBALL 3 - 1"x2"x18" WOOD STAKES WITH CENTERED 3/8" HOLE DRIVEN IN LINE WITH STRAP EQUALLY SPACED AROUND TREE NOTES: 1, SCARIFY ROOT MASS OF CONTAINERIZED PLANT MATERIAL. 2, INSTALL CONTAINERIZED PLANTS AT FINSHED GRADE 3. TAMP PLANTING MIX FIRMLY AS PIT IS FILLED AROUND EACH PLANT BALL. =GL� 4. OMIT COLLAR AROUND EACH SHRUB 6• SLIP KNOT WITH STOP KNOT. 6" LARGER THAN TREE DWAETER WHEN IRRIGATION SYSTEM IS PRESENT MULCH AWAY FROM 5. SOAK EACH PLANT BALL AND VKEEP TRUNK I" To 2• PIT IMMEDIATELY AFTER -4" MAXIMUM LAYER OF MULCH INSTALLATION. REMOVE TYPICAL EXCESS SOIL FROM ROOT CROWN REMOVE TOP 1/3 BURLAP UNDISfURBEO SOIL AND ANY NAILS/PINS, ETC. ROOT BALL DIA. 12" REMOVE TOP 1/3 OF WIRE VARIES BASKET WHERE PRESENT RAISE PR BOTTOM TO SET ROOT CROWN AT THE CORRECT HEIGHT. FIRM SOIL UNDER ROOT BALL ALL TREES SHALL MEET AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z60.1-2004) FOR EXAMPLE: CALIPER HEIGHT (RANGE) MAX. HEIGHT MIN. ROOT BALL DIA. MIN. ROOT BALL DEPTH 2" 12-14' 1624" 16" 3" 14-16' 18' 32" 21" TREE PLANTING FOR SINGLE AND MULTI -STEM TREES w w U) X w FINISH GRADE CROWN HEIGHT IN INCHES EQUALS MEDIAN AS SPECIFIED WIDTH IN FEET TO 12" MAX. FINAL GRADE 10' (EX,) -10' (EX.�� EXISTING GRADE TYPICAL BED CROWNING SCALE: NTS CLDSM 40.01 EXIST. TREE # 4 REBAR 12" ON CENTER /-6" THICK SIDEWALK ON WASHED STONE EXP. JOINT /­ EXP. JOINT B 4" THI SIDEW B HICK WALK GROOVE JOINT REBAR "CHAIRS" A GROOVE JOINT SECTION A -A ZEBAR ,R "CHAIRS" CFI ILL 3:1 SLOPE) .,,.,.JUND/PROTECT ROOTS WITH #57 STONE (DEPTH VARIES) EXIST. TREE # 4 REBAR 12" ON CENTER EXIST.4" THICK SIDEM TYP. COLD MIN. 2" H1 4" LAYER OF APPROVEC MULCH `V" TRENCH AROUt ENTIRE PLANTING I EDGE 0 PLANTINv ow SHRUB PLANTING BED PLACE WASHED STONE CAREFULLY / L- #57 STONE TO AVOID DAMAGE TO EXISTING ROOTS L DO NOT COMPACT SOIL JOINT 6" THICK SIDEWALK - EXP. JOINT • CITY OF CHARLOTTE REINFORCED CONCRETE SIDEWALK LAND DEVELOPMENT STANDARDS STD. NO. CHARLOTTE_ INCLUDES CHARLOTTE ETJ (BRIDGING TREE ROOTS) 140.11 PLANT SCHEDULE TREES CODE QTY BOTANICAL / COMMON NAME CONT CAL SIZE • LSR 3 LIQUIDAMBAR STYRACIFLUA'ROTUNDILOBA' TM B & B 3" CAL 10'-12' HT ROUND -LOBED SWEET GUM • QBB 1 QUERCUS BICOLOR 'BONNIE AND MIKE TM B & B 2" CAL 10'-12' HT BEACON OAK • QRU 4 QUERCUS RUBRA B & B 2" CAL 10'-12' HT RED OAK • UPA 1 ULMUS PARVIFOLIA 'ALLEE' B & B 3" CAL 10'-12' HT ALLEE LACEBARK ELM SHRUBS CODE QTY BOTANICAL / COMMON NAME CONT MIN HEIGHT MIN WIDTH SPACING LCR 2 LOROPETALUM CHINENSE 'RUBY' 7 GAL 24" 24" AS SHOWN 0 RUBY LOROPETALUM xxx PLANT CODE XX PLANT QUANTITY NOTES: IF GRAPHIC REPRESENTATION OF PLANTINGS ON PLANS DO NOT MATCH QUANTITIES IN PLANT SCHEDULE, GRAPHIC REPRESENTATION OF PLANTINGS WILL GOVERN. TREES NOT IN A LANDSCAPE BED SHALL RECEIVE A 4' DIAMETER MULCH RING. LIMITS OF IRRIGATION INCLUDE DENOTED LANDSCAPE BEDS, ALL SOD/SEED AREAS, AND TREES NOT LOCATED IN A LANDSCAPE BED. ALL DISTURBED AREAS SHALL IN A LANDSCAPE BED SHALL RECEIVE SOD/SEED. CONTRACTOR TO VERIFY WITH LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. SPACING VARIES SEE LANDSCAPE PLAN " EACH PLANT BALL TO MINIMIZE SETTLEMENT TYPICAL PLANTING BED DETAIL (P. TAGGERED ROWS EQUAL SPACING J EDGE OF BETWEEN ALL PLANTS BPELANTING TYPICAL PLANTING BED PLAN REMARKS STRAIGHT TRUNK, CENTRAL LEADER, GOOD FOLIAGE, FULL CROWN STRAIGHT TRUNK, CENTRAL LEADER, GOOD FOLIAGE, FULL CROWN STRAIGHT TRUNK, CENTRAL LEADER, GOOD FOLIAGE, FULL CROWN STRAIGHT TRUNK, GOOD FOLIAGE, FULL CROWN REMARKS FULL, HEALTHY FOLIAGE TOP TALL DIAMETER SOIL LINE 2" MAXIMUM OF SOIL COVERING ACCEPTABLE )WN TOP OF BALL AS DUG NATURAL SOIL LINE ALL DIAMETER EFFECTIVE BALL DIAMETER UNACCEPTABLE SOIL COVERING CROWN U R B A N DESIGN PARTNERS 1318-e6 central ave. P 704.334.3303 charlotte, nc 28205 F 704.334.3305 urbandesignpartners.com nc firm no: P-0418 sc coa no: C-03044 ACCEPTABLE CONDITION UNACCEPTABLE CONDITION °0000000000000000 (AS DELIVERED) (AS DELIVERED) NOTE: A ROOT COLLAR EXCAVATION FOR ALL TREES SPECIFIED WILL BE DONE BY THE CITY ARBORIST TO ENSURE THAT to -Ao M012 WILL BE DONE BY THE CITY ARBORIST TO ENSURE THAT TREES WERE NOT PLANTED/GROWN TOO DEEPLY AT SOURCE � w� _° (NURSERY). LANDSCAPE CONTRACTOR SHALL HAVE SUPPLIER MARK GROUND LEVEL LINE ABOVE ROOT BALL. IF CITY ARBORIST o °o!;V y�o°° o DETERMINES THAT THERE IS EXCESSIVE SOIL OVER THE ROOT CROWN, THESE TREES WILL BE REJECTED. °°o�Oj °Ooo°°00000°-�°°° - "0000000000 SCALE: NTS ROOT CROWN DEPTHS SCALE: NTS CLDSM40.05 (TREE ROOT BALL CONDITION ON TREES FROM SUPPLIERS) CLDSM40.09 09/30/2020 TREE PLANTING & PRESERVATION REQUIREMENTS: GENERAL PLANTING NOTES: PLANT MATERIAL 1. QUANTITIES NECESSARY TO COMPLETE THE WORK ON THE DRAWINGS SHALL BE FURNISHED BY THE 1. MINIMUM TREE SIZE AT PLANTING IS 2" CALIPER AND 8' TALL FOR SINGLE -STEM TREES. ALL MULTI -STEM CONTRACTOR. QUANTITY ESTIMATES HAVE BEEN MADE CAREFULLY, BUT THE LANDSCAPE ARCHITECT ASSUMES PLANTS MUST BE TREE FORM. MINIMUM TREE SIZE AT PLANTING IS 2-INCH CALIPER (FOR SINGLE STEM NO LIABILITY FOR ERRORS OR OMISSIONS. HIS ESTIMATES ARE ONLY AN AID FOR CLARIFICATION OF UNITS AND TREES). ALL MULTI -STEM PLANTS MUST BE TREE FORM, MAXIMUM 3 TO 5 TRUNKS, AND MINIMUM 10' TALL. A CHECK FOR THE CONTRACTOR TO COMPARE WITH HIS OWN ESTIMATES. DIFFERENCES SHALL BE BROUGHT TO WHERE 3" SINGLE -STEM CALIPER TREES ARE SPECIFIED/REQUIRED THE MINIMUM HEIGHT SHALL BE 10' TALL, THE ATTENTION OF THE LANDSCAPE ARCHITECT. NO EXTRA COMPENSATION SHALL BE ALLOWED FOR EXTRA IF MULTI -STEM TREES ARE SPECIFIED THEN THEY SHALL BE A MINIMUM OF 12, TALL. QUANTITIES NECESSARY TO COMPLETE THE WORK. U ~o 2. ALL NEW TREES MUST HAVE STRAIGHT TRUNKS WITH STRONG CENTRAL LEADERS INTACT TO THE TOP OF THE (D CROWN UNLESS MULTI -STEM TREES ARE SPECIFIED. ALL REQUIRED TREES SHALL BE TYPICAL OF THEIR 2. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLATION OF PLANT MATERIALS ACCORDING TO THE i � SPECIES AND VARIETY, HAVE NORMAL GROWTH HABITS, HAVE WELL -DEVELOPED BRANCHES, BE VIGOROUS AND DRAWINGS AND PLANT SCHEDULE. CONTRACTOR SHALL PROVIDE SPECIFIC CULTIVARS AND/OR VARIETIES AS J Q N HAVE FIBROUS ROOT SYSTEMS. TREES WITH MAJOR GIRDLING ROOTS WILL NOT BE ACCEPTED. TREES WITH INDICATED ON THE PLANT SCHEDULE. ANY SUBSTITUTIONS INSTALLED WITHOUT PRIOR APPROVAL OF J >, U CO -DOMINANT BRANCHING WILL NOT BE ACCEPTED. TREES THAT HAVE BEEN SHEARED, TOPPED OR CUT BACK LANDSCAPE ARCHITECT WILL BE REJECTED AND SHALL BE REPLACED BY THE CONTRACTOR AT NO EXTRA COST z TO MULTIPLY THE BRANCHING STRUCTURE WILL NOT BE ACCEPTED. TREES SHALL BE FREE OF ABRASIONS, TO THE OWNER. > dj DAMAGE, DISEASE, PESTS AND CRACKS. ALL PRUNING CUTS GREATER THAN 1% INCH DIAMETER SHALL HAVE 'L m CALLUS TISSUE FORMED PRIOR TO PLANTING. NO PRUNING CUT ON THE TRUNK SHALL BE MORE THAN 3. PLANTING PLANS INDICATE DIAGRAMMATIC LOCATIONS ONLY. SITE ADJUSTMENTS OF PLANTING DESIGN AND = L RELOCATION OF PLANT MATERIALS DUE TO ON SITE CONDITIONS SHALL BE APPROVED BY THE LANDSCAPE _ ONE-HALF THE DIAMETER OF THE CENTRAL LEADER AT THE HEIGHT WHERE THE CUT WAS MADE. ROOT � C� � FLARES SHALL BE LOCATED AT GRADE. TREES WITH MORE THAN 2" OF SOIL COVERING THE ROOT BALL/FLARE ARCHITECT PRIOR TO INSTALLATION. PLANTS INSTALLED PRIOR TO LANDSCAPE ARCHITECT'S APPROVAL ARE r 1 = rn U FROM WILL NOT BE ACCEPTED (CLDS.40.09). SUBJECT TO RELOCATION BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. �.J T 3. SIZE OF REQUIRED PLANTS, SPREAD OF ROOTS AND SIZE OF BALLS SHALL BE IN ACCORDANCE WITH ANSI 4. PLANTS SHALL BE SPECIMEN QUALITY AND SHALL BE SOUND, HEALTHY AND VIGOROUS, WELL -BRANCHED, Z60.1 (LATEST EDITION) AS PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION, EXCEPT AND DENSELY FOLIATED WHEN IN LEAF. PLANT MATERIAL SHALL BE FIRST QUALITY STOCK AND SHALL WHERE SPECIFIED/AUTHORIZED BY URBAN FORESTRY. CONFORM TO THE CODE OF STANDARDS SET FORTH IN THE CURRENT EDITION OF THE AMERICAN STANDARDS 4. ALL REQUIRED TREES OF A PARTICULAR SPECIES AND VARIETY SHALL BE UNIFORM IN SIZE AND FOR NURSERY STOCK SPONSORED BY THE AMERICAN ASSOCIATION OF NURSERYMEN, INC. CONFIGURATION. 5. PERIMETER TREES IN URBAN ZONES SHALL BE 3" IN CALIPER AND BE FREE OF BRANCHES UP TO 6' FROM 5. HEIGHT AND SPREAD DIMENSION SPECIFIED REFER TO THE MAIN BODY OF THE PLANT AND NOT FROM THE TOP OF ROOT CROWN (BALL). BRANCH TIP TO TIP. IF A RANGE OF SIZE IS GIVEN, NO PLANT SHALL BE LESS THAN THE MINIMUM SIZE AND 6. A MINIMUM OF 50% OF NEW TREES MUST BE NATIVE SPECIES, AND SITES WITH MORE THAN 20 TREES NOT LESS THAN 50% OF THE PLANTS SHALL BE AS LARGE AS THE MAXIMUM SIZE SPECIFIED. REQUIRED WILL HAVE TO INSTALL MULTIPLE (3 OR MORE) SPECIES PURSUANT TO THE TREE ORDINANCE GUIDELINES. 6. SHADE TREES SHALL HAVE A STRONG CENTRAL LEADER UNLESS OTHERWISE SPECIFIED. 7. 75% OF REQUIRED TREES MUST BE LARGE MATURE SPECIES EXCEPT IN SITUATIONS WITH OVERHEAD POWER LINE CONFLICTS. 7. LEAVES MUST BE OF MEDIUM FOLIAGE, ALL GOOD LEAVES, MAXIMUM OF 10% CHLOROSIS ALLOWED, WITH NO EXTREME SUCCULENCE PLACE PLANTS UPRIGHT AND TURNED SO THAT THE MOST ATTRACTIVE SIDE IS VIEWED. PLANTING REQUIREMENTS MAXIMUM 3 TO 5 TRUNKS, AND MINIMUM 8 FEET TALL. 8. SEE CLDS 40.01 & 40.09 (ON PLAN) FOR DETAILED TREE PLANTING REQUIREMENTS. 8. ROOTS MUST BE STURDILY ESTABLISHED IN BALL THAT HAS BEEN TIGHTLY WRAPPED AND SECURELY TIED 9. PLASTIC HOSE PARTS WILL NOT BE ACCEPTED FOR TREE STAKING. SEE CLDS 40.01 FOR APPROVED STAKING WITH TWINE OR WIRE, OR PINNED. METHOD/MATERIALS. 10. ALL STRAPPING, AND TOP 1/3 OF WIRE BASKET AND BURLAP MUST BE CUT AWAY AND REMOVED FROM ROOT 9. PLACE PLANTS UPRIGHT AND TURNED SO THAT THE MOST ATTRACTIVE SIDE IS VIEWED. BALL WHEN PLANTING. 11. FOR NEW PLANTING AREAS, REMOVE ALL PAVEMENT, GRAVEL SUB -BASE AND CONSTRUCTION DEBRIS; REMOVE 10. PROVIDE 4" THICKNESS MULCH AT ALL PLANTS AND PLANTING BEDS. MULCH SHALL BE SINGLE COMPACTED SOIL AND ADD 18" NEW TOPSOIL, OR TILL AND AMEND THE TOP 18" OF EXISTING SOIL TO MEET HAMMERED HARDWOOD MULCH (UNLESS NOTED OTHERWISE). IT SHALL BE CLEAN, FRESH, AND FREE OF TOPSOIL/PLANTING MIX STANDARDS FOR TREES (WITHIN ENTIRE MINIMUM AREA OF 274 SQUARE FEET). STICKS, BRANCHES, SOIL OR OTHER FOREIGN MATERIAL. LO 12. TREES PLANTED ON PUBLIC PROPERTY WILL NEED APPROVAL FROM THE CITY ARBORIST AND/OR NCDOT. 11. BACKFILL PLANTING MIXTURE SHALL BE ONE PART APPROVED PLANTING SOIL MIXED WITH ONE PART 13. REVIEW SOIL REQUIREMENTS IN THE TREE ORDINANCE GUIDELINES AT: HTTP: //CHARLOTTENC.GOV/LD THEN NATIVE SOIL FROM THE TREE PIT OR SHRUB BED AREA. LANDSCAPE CONTRACTOR SHALL SUBMIT SAMPLES OF LO CLICK TREES. PLANTING SOIL TO BE USED TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO PLANTING. V, O UTILITY ISSUES 12. PLANTS SHALL BE SUBJECT TO REVIEW BY LANDSCAPE ARCHITECT AT NURSERY OR ON SITE PRIOR TO 70 00 14. IF ANY UTILITY IS BEING INSTALLED IN OR NEAR ANY REQUIRED TREE(S) OR TREE SAVE AREA(S), CALL URBAN PLANTING. LANDSCAPE ARCHITECT WILL BE THE SOLE JUDGE OF THE QUALITY AND ACCEPTABILITY OF CV FORESTRY SPECIALIST TO RESOLVE PRIOR TO UTILITY INSTALLATION. MATERIALS AND PLACEMENT. CONTRACTOR SHALL SUBMIT PHOTOS OF ALL TREES WITH BID SUBMITTAL IF 15. LARGE MATURING TREES MAY NOT BE PLANTED WITHIN 25' OF OVERHEAD POWER DISTRIBUTION OR REQUESTED BY LANDSCAPE ARCHITECT OR OWNER. }� z TRANSMISSION LINES.a) 16. IF TREES CONFLICT WITH ANY UTILITIES OR SIGNS; CALL URBAN FORESTER TO RESOLVE BEFORE PLANTING. 13. THE LANDSCAPE CONTRACTOR SHALL TAKE SOIL SAMPLES FROM ALL PARTS OF THE SITE AND SHALL O 17. ADJUST TREE PLANTING LOCATIONS TO AVOID EXISTING UNDERGROUND UTILITIES. PLANT 15' FROM ALL HAVE THEM TESTED BY THE LOCAL COUNTY AGENT. THE CONTRACTOR SHALL PROVIDE ONE COPY OF THE Q � UNDERGROUND UTILITIES. TEST RESULTS TO THE LANDSCAPE ARCHITECT PRIOR TO ORDERING PLANT MATERIALS OR MAKING ANY O 18. NO LIGHT POLES, UTILITIES OR TRANSFORMERS CAN BE INSTALLED IN TREE ISLANDS. AMENDMENTS TO THE ON SITE SOIL. ANY SOIL AMENDMENTS REQUIRED AS INDICATED BY THE SOIL TEST ^1 M 19. COMMERCIAL SCALE LIGHTING (> 15' IN HEIGHT) MUST BE A MINIMUM DISTANCE OF 30' FROM A TREE. SHALL BE PROVIDED BY THE LANDSCAPE CONTRACTOR. THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE W PEDESTRIAN SCALE LIGHTING (5 15' IN HEIGHT) MUST BE A MINIMUM DISTANCE OF 15' FROM A TREE. SHOW LANDSCAPE ARCHITECT OF AMENDMENTS AND OBTAIN A WRITTEN APPROVAL FOR PROPOSED AMENDMENTS. ^ SITE LIGHTING ON LANDSCAPE PLAN. U 14. FERTILIZER SHALL BE A COMPLETE FERTILIZER; 50% OF NITROGEN OF WHICH IS DERIVED FROM NATURAL CI] TREE SAVE AND PRESERVATION ORGANIC SOURCES OR UREAFORM. FERTILIZER SHALL BE DELIVERED TO THE SITE IN STANDARD SIZE 20. TREE PROTECTION MUST BE INSTALLED AND VERIFIED BY URBAN FORESTRY PRIOR TO STARTING ANY UNOPENED CONTAINERS WHICH SHOW THE WEIGHT, CHEMICAL ANALYSIS, AND MANUFACTURER. IT SHALL BE U Q CONSTRUCTION ACTIVITY. STORED IN A DRY LOCATION UNTIL ITS USE. FERTILIZER FOR TREES, SHRUBS, AND GROUNDCOVER AREAS '^ O 21. SHOW TREE PROTECTION AND TREES SAVE AREAS ON EROSION CONTROL, GRADING AND LANDSCAPE PLAN SHALL BE A SLOW RELEASE TYPE AND SHALL BE APPLIED AS FOLLOWS: SHEETS. 0) 22. COMMERCIAL TREE SAVE AREAS MUST BE RECORDED ON A FINAL PLAT WITH THE MECKLENBURG COUNTY TREES AND SHRUBS TREES: 1 LB / INCH OF CALIPER -0 Z REGISTER OF DEEDS BEFORE URBAN FORESTRY HOLDS CAN BE RELEASED. A 10' NO BUILD ZONE AROUND MARCH -MAY 10-10-10 SHRUBS: Y2 LB / INCH HEIGHT TREE SAVE AREAS MUST BE REFERENCED ON THE PLAT. JUNE-OCTOBER 6-10-10 r 23. TREE SAVE AREAS SHALL BE FREE OF INVASIVE PLANT SPECIES. IF AN AREA PROPOSED FOR TREE SAVE NOVEMBER-FEBRUARY 6-12-12 CV CONTAINS INVASIVE PLANT SPECIES AT TIME OF PROPOSAL, SUCH INVASIVE PLANT SPECIES SHALL BE r REMOVED PRIOR TO FINAL CO. 15. LANDSCAPE CONTRACTOR SHALL PERFORM PERCOLATION TESTS IN ALL TREE PITS. IF PITS DO NOT DRAIN 24. THE AREA OF ANY EASEMENTS (WATER, SEWER, UTILITY, ETC.) CAN NOT BE COUNTED TOWARD THE TREE WITHIN 30 MINUTES, CONTACT LANDSCAPE ARCHITECT AND DO NOT PLANT THE TREE WITHOUT ON SITE SAVE REQUIREMENT. INSPECTION OF DRAINAGE. LANDSCAPE ARCHITECT MAY REQUIRE ADDITIONAL SUBSURFACE DRAIN LINES FROM 25. ANY ALTERATIONS TO TREE SAVE AREAS MUST BE ACCOMPLISHED WITHOUT MECHANIZED EQUIPMENT. THE TREE PITS. 26. NO STRUCTURE WILL BE ALLOWED WITHIN 10' OF TREE SAVE AREAS UNLESS APPROVED BY URBAN FORESTRY. 27. ALL TREES ON PUBLIC PROPERTY ARE PROTECTED AND REMOVAL MUST BE PERMITTED BY THE CITY ARBORIST 16. IF SURFACE DRAINAGE IS NOT SUFFICIENT (STANDING WATER) NOTIFY LANDSCAPE ARCHITECT IN WRITING (704)336-4262. BEFORE INSTALLING THE PLANTS, OTHERWISE CONTRACTOR SHALL BE TOTALLY REPONSIBLE FOR THE 28. CONTACT URBAN FORESTRY SPECIALIST PRIOR TO ANY CRANE SET-UP, MACHINERY OPERATION OR GUARANTEE AND LIVABILITY OF THE PLANTS. TEMPORARY BUILDING ERECTION THAT MAY IMPACT CHARLOTTE TREE ORDINANCE PROTECTED TREES OR TREE SAVE AREAS, INCLUDING TREES LOCATED IN STREET RIGHT OF WAY. IMPACTS MAY INCLUDE BUT ARE NOT 17. ALL UNDERGROUND UTILITIES SHALL BE LOCATED BEFORE DIGGING. THE CONTRACTOR SHALL BE FULLY LIMITED TO: ENCROACHING WITHIN TREE DRIP -LINES, EXCAVATION, SOIL COMPACTION, TREE TRIMMING, RESPONSIBLE FOR ALL DAMAGE OF UNDERGROUND OR OVERHEAD UTILITY LINES. ERECTING AND DISMANTLING OF CONSTRUCTION CRANES. 18. CERTIFICATE OF INSPECTION AS MAY BE REQUIRED BY LAW FOR TRANSPORTATION OF PLANT MATERIALS GENERAL SHALL ACCOMPANY EACH INVOICE FOR EACH SHIPMENT OF PLANTS. CERTIFICATES SHALL BE FILED WITH 29. SUBMIT REQUIRED CO/HOLD RELEASE FORM AT HTTP: //CHARLOTTENC.GOV/LD FOR AN INSPECTION OF TREE LANDSCAPE ARCHITECT PRIOR TO ACCEPTANCE OF MATERIAL. INSPECTION BY STATE OR FEDERAL AUTHORITIES (jj PROTECTION/PLANTING AREAS, A MINIMUM OF 5 DAYS BEFORE THE CO/HOLD RELEASE IS NEEDED. AT THE PLACE OF GROWTH DOES NOT PRECLUDE REJECTION OF THE MATERIAL BY THE LANDSCAPE ARCHITECT. ZO 30. VISIT CITY OF CHARLOTTE'S LAND DEVELOPMENT WEBSITE FOR ADDITIONAL INFORMATION AND URBAN 19. ALL PLANT MATERIALS AND INSTALLED LANDSCAPE SUPPLIES SHALL BE WARRANTED FOR A PERIOD OF CO FORESTRY REQUIREMENTS: HTTP: //CHARLOTTENC.GOV/LD THEN CLICK TREES. ONE YEAR AFTER FINAL ACCEPTANCE OF THIS PROJECT. w M TOPSOIL/PLANTING MIX - MINIMUM REQUIREMENTS: 20. CONTRACTOR'S PRICES SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY TO COMPLETE THE WORK 31. WHERE PAVEMENT CUTOUTS ON RENOVATED SITES ARE REQUIRED AND/OR WHERE NEW PLANTING STRIPS OR (i.e. MULCH, PLANTING, SOIL MIX, WOOD AND WIRE STAKING MATERIAL, ETC.). ISLANDS ARE REQUIRED, ALL PAVEMENT, CONSTRUCTION DEBRIS AND GRAVEL SUB -BASE MUST BE REMOVED Cp BEFORE PREPARING SOIL AND PLANTING TREES. EXISTING COMPACTED SOIL MUST BE REMOVED AND REPLACED 21. THE COMPLETION OF THE CONTRACT WILL BE ACCEPTED AND NOTICE OF COMPLETION RECORDED ONLY WITH 24" OF TOPSOIL/PLANTING MIX -OR- EXISTING SOIL MAY BE UNCOMPACTED TO A DEPTH OF 24" AND WHEN THE ENTIRE CONTRACT IS COMPLETED TO THE SATISFACTION OF THE LANDSCAPE ARCHITECT, OWNER, AMENDED TO MEET TOPSOIL STANDARDS FOR THE ENTIRE PLANTING AREA. AND THE OWNER'S CONSTRUCTION REPRESENTATIVE. WITHIN TEN DAYS NOTICE BY THE CONTRACTOR OF 32. SOIL IN ALL PLANTING STRIPS OR ISLANDS, WHETHER EXISTING OR NEW(ON NEW OR RENOVATED SITES), MUST SUBSTANTIAL COMPLETION THE LANDSCAPE ARCHITECT WILL INSPECT THE PROPERTY. HE WILL EITHER p MEET THE MINIMUM TOPSOIL/PLANTING MIX SPECIFICATIONS. SOIL AMENDMENTS OR FRESH TOPSOIL/PLANTING APPROVE THE WORK FOR THE OWNER'S ACCEPTANCE OR WILL ISSUE A "PUNCH LIST" OF ITEMS TO BE MIX ARE OFTEN NEEDED FOR PLANTING AREAS AT SITES WHERE ORIGINAL TOPSOIL IS OF POOR QUALITY, COMPLETED OR CORRECTED. IF A PUNCH LIST IS ISSUED, FINAL ACCEPTANCE WILL BE DONE AS SOON AS THE HEAVILY COMPACTED OR WHERE TOPSOIL HAS BEEN COMPLETELY REMOVED DURING GRADING. CONTRACTOR COMPLETES ALL PUNCH LIST ITEMS. z 33. TOPSOIL/PLANTING MIX SHOULD BE NATURAL, FERTILE, AGRICULTURAL SOIL CAPABLE OF SUSTAINING VIGOROUS PLANT GROWTH. IT SHOULD BE UNIFORM COMPOSITION THROUGHOUT, WITH ADMIXTURE OF SUBSOIL. IT SHOULD 22. AMENDED SOIL MEDIA REQUIREMENTS: A PLANTING MIX MAY BE DEVELOPED THAT WILL BE AN BE FREE OF STONES, LUMPS, LIVE PLANTS AND THEIR ROOTS, STICKS AND OTHER EXTRANEOUS MATTER. ACCEPTABLE PLANTING MEDIA BY AMENDING THE EXISTING SOIL OR BY REMOVING THE EXISTING SOIL AND TOPSOIL SHOULD NOT BE USED WHILE IN A FROZEN OR MUDDY CONDITION. REPLACING IT WITH NEW PLANTING MIX. THE PLANTING MIX SHALL HAVE UNIFORM COMPOSITION Project No: 19-133 34. TOPSOIL/PLANTING MIX SHALL HAVE AN ACIDITY RANGE OF PH 5.5-7.0 AND THE FOLLOWING COMPOSITION: THROUGHOUT, WITH A MIXTURE OF SUBSOIL. IT SHALL BE FREE OF STONES, LUMPS, LIVE PLANTS AND CLAY (RED CLAY, WELL PULVERIZED) MINIMUM 10%; MAXIMUM 35% THEIR ROOTS, STICKS, AND OTHER EXTRANEOUS MATTER. IT SHALL CONTAIN NO MAN MADE MATERIALS Date: 09.30.2020 COMPOST*/ORGANIC MINIMUM 5%; MAXIMUM 10% UNLESS OTHERWISE SPECIFIED. PLANTING MIX SHALL NOT BE USED WHILE IN A FROZEN OR MUDDY SILT MINIMUM 30%; MAXIMUM 50% CONDITION. Designed by: UDP COARSE SAND (FREE OF ROCKS, 0.5 TO 1.0 MM F) MINIMUM 30%; MAXIMUM 45% *ORGANIC MATERIAL SUCH AS SAWDUST OR LEAF MOLD THAT HAS COMPLETED THE DECOMPOSITION PROCESS. *NOTE: CONTRACTOR TO PROVIDE TEST SAMPLES OF AMENDED SOIL WITH TESTING DATA FOR ALL Drawn B UDP BED AREAS AMENDED ON SITE. TEST SAMPLES SHALL FALL WITHIN TOLERANCES SHOWN ABOVE. y PLANTING RECOMMENDATIONS: PLANTING SHALL NOT BEGIN UNTIL SOIL HAS BEEN AMENDED AND SOIL TEST SAMPLES HAVE BEEN 35. ALL PLANTING AREAS SHOULD BE TESTED FOR PROPER DRAINAGE. DRAINAGE SHOULD BE CORRECTED AS REVIEWED AND APPROVED BY OWNER AND LANDSCAPE ARCHITECT. Sheet No: NECESSARY TO INSURE PROPER TREE GROWTH AND SURVIVAL. THE FOLLOWING LEVEL OF NUTRIENT ELEMENTS IS RECOMMENDED FOR PROPER GROWTH: CALCIUM 55 - 80% MAGNESIUM 10 - 30% POTASSIUM 5 - 8% LS-200 0 _ 0 0 0 0 CHARLOTTE SITE PLAN NOTES 1. GENERAL PROVISIONS COMPRISE OF BRICK, CEDAR SHAKE, WOOD SIDING, A. THESE DEVELOPMENT STANDARDS FORM A PART OF FIBER CEMENT SIDING, STUCCO, MASONRY AND/OR THE REZONING PLAN ASSOCIATED WITH THE REZONING OTHER MATERIAL APPROVED BY THE CITY PLANNING PETITION, FILED BY CoHab LLC (THE PETITIONER), DIRECTOR. TO ACCOMMODATE THE DEVELOPMENT OF 28 RESIDENTIAL DWELLING UNITS ON AN APPROXIMATELY B. PITCHED ROOFS, IF PROVIDED, SHALL BE 0.5177 ACRE SITE LOCATED ON THE SOUTHWEST SYMMETRICALLY SLOPED NO LESS THAN 5:12, EXCEPT CORNER OF SEIGLE AVENUE & 15TH STREET, MORE THAT ROOFS FOR PORCHES AND ATTACHED SHEDS PARTICULARLY DEPICTED ON THE REZONING PLAN MAY BE NO LESS THAN 2:12, UNLESS A FLAT ROOF (THE "SITE"). THE SITE IS COMPRISED OF TAX PARCEL ARCHITECTURAL STYLE IS EMPLOYED. NUMBERS 08109921, 081 0991 4 & 08109913. C. PERMITTED SLOPED ROOF MATERIALS ARE ASPHALT B. DEVELOPMENT OF THE SITE WILL BE GOVERNED BY SHINGLES, COMPOSITION SHINGLES, WOOD SHINGLES, THE REZONING PLAN, THESE DEVELOPMENT TIN, STANDING SEAM METAL, AND WOOD SHAKES. STANDARDS AND THE APPLICABLE PROVISIONS OF THE CITY OF CHARLOTTE ZONING ORDINANCE (THE D. THE SCHEMATIC DEPICTION OF SIDEWALKS, DRIVEWAY, "ORDINANCE"). STREETS AND OTHER DEVELOPMENT MATTERS AND SITE ELEMENTS (COLLECTIVELY "THE C. UNLESS THE ZONING PLAN OR THESE DEVELOPMENT DEVELOPMENT/SITE ELEMENTS") SET FORTH ON THE STANDARDS ESTABLISH MORE STRINGENT STANDARD, REZONING PLAN SHOULD BE REVIEWED IN THE REGULATIONS ESTABLISHED UNDER THE CONJUNCTION WITH THE PROVISION OF THESE ORDINANCE FOR THE MUDD-CD ZONING DISTRICT DEVELOPMENT STANDARDS. THE LAYOUT, LOCATIONS, SHALL GOVERN THE DEVELOPMENT AND USE OF THE SIZES AND FORMULATIONS OF THE DEVELOPMENT/SITE SITE. ELEMENT DEPICTED BY THE REZONING PLAN ARE GRAPHIC REPRESENTATIONS OF THE DEVELOPMENT/ D. THE DEVELOPMENT AND USES DEPICTED ON THE SITE ELEMENT PROPOSED. CHANGES TO THE REZONING PLAN ARE SCHEMATIC IN NATURE AND ARE REZONING PLAN NOT ANTICIPATED BY THE REZONING INTENDED TO DEPICT THE GENERAL ARRANGEMENT OF PLAN WILL BE REVIEWED AND APPROVED AS ALLOWED SUCH USES AND IMPROVEMENTS ON THE SITE. BY SECTION 6.207 OF THE ORDINANCE. ACCORDINGLY, THE ULTIMATE LAYOUT, LOCATIONS AND SIZES OF THE DEVELOPMENT AND SITE ELEMENT E. THE HEIGHT OF THE BUILDING SHALL NOT EXCEED 44 DEPICTED ON THE REZONING PLAN ARE GRAPHIC FT. TALL AS DETERMINED BY THE ORDINANCE REPRESENTATIONS OF THE PROPOSED DEVELOPMENT STANDARDS FOR MEASUREMENT OF HEIGHT. AND SITE ELEMENTS, AND THEY MAY BE ALTERED OR MODIFIED IN ACCORDANCE WITH THE SETBACK, YARD, F. ALL PRINCIPAL AND ACCESSORY BUILDINGS ABUTTING LANDSCAPING AND TREE SAVE REQUIREMENTS SET A NETWORK REQUIRED PUBLIC OR PRIVATE STREET FORTH ON THIS REZONING PLAN AND THE SHALL COMPRISE A MINIMUM OF 30% THAT BUILDING'S DEVELOPMENT STANDARDS, PROVIDED, HOWEVER, THAT ENTIRE FAQADE FACING SUCH NETWORK STREET USING ANY SUCH ALTERATIONS AND MODIFICATIONS SHALL BRICK, NATURAL STONE (OR ITS SYNTHETIC NOT MATERIALLY CHANGE THE OVERALL DESIGN INTENT EQUIVALENT) STUCCO OR OTHER MATERIAL APPROVED DEPICTED ON THE REZONING PLAN. THE SETBACKS, BY THE PLANNING DIRECTOR. AS SHOWN ON THE SITE PLAN, ARE: 16' FRONT SETBACK FROM THE BACK OF CURB ON SEIGLE G. LIST THE FOLLOWING AS PROHIBITED BUILDING AVENUE; 16' SIDE SETBACK FROM THE BACK OF MATERIALS: VINYL SIDING AS A PROHIBITED EXTERIOR CURB ON 15TH STREET; 10' SIDE SETBACK ON THE BUILDING MATERIAL EXCEPT ON HAND RAILS, WINDOWS SOUTHWEST PROPERTY LINE SHARED WITH THE OR DOOR TRIM; CONCRETE MASONRY UNITS NOT ADJACENT COMMERICAL AND A 20' REARYARD ARCHITECTURALLY FINISHED. SETBACK AGAINST THE ADJACENT RESIDENTIAL FACING 15TH. H. BUILDINGS SHALL BE PLACED SO AS TO PRESENT A FRONT OR SIDE FAQADE TO ALL NETWORK REQUIRED E. FUTURE AMENDMENTS TO REZONING PLAN AND/OR STREETS (PUBLIC OR PRIVATE); BUILDINGS SHALL THESE DEVELOPMENT STANDARDS MAY BE APPLIED FRONT A MINIMUM OF 60% OF THE TOTAL NETWORK FOR BY THE THEN OWNER(S) OF THE SITE IN REQUIRED STREET FRONTAGE ON THE SITE (EXCLUSIVE ACCORDANCE WITH THE PROVISION OF CHAPTER 6 OF OF DRIVEWAYS, PEDESTRIAN ACCESS, POINTS, THE ORDINANCE. ALTERATIONS TO THE REZONING PLAN ACCESSIBLE OPEN SPACE, TREE SAVE OR NATURAL ARE SUBJECT TO SECTION 6.207 OF THE ORDINANCE. AREAS, TREE REPLANTING AREAS AND STORM WATER FACILITIES); PARKING LOTS SHALL NOT BE LOCATED 2. PERMITTED USES BETWEEN ANY BUILDING AND ANY NETWORK REQUIRED A.THE SITE MAY BE UTILIZED FOR ANY RESIDENTIAL PUBLIC OR PRIVATE STREET; DRIVEWAYS INTENDED TO USES AVAILABLE IN THE MUDD ZONING DISTRICT, SERVE SINGLE UNITS SHALL BE PROHIBITED ON ALL INCLUDING A RESIDENTIAL COMMUNITY CONTAINING NETWORK REQUIRED STREETS. UP TO 28 RESIDENTIAL DWELLING UNITS, AND TO ANY I. BUILDINGS EXCEEDING 120 FEET IN LENGTH SHALL INCIDENTAL AND ACCESSORY USES RELATING THERETO, INCLUDE MODULATIONS OF THE BUILDING INCLUDING WITHOUT LIMITATION, A PROPERTY MASSING/FAQADE PLANE (SUCH AS RECESSES, MANAGEMENT OFFICE, THAT ARE ALLOWED IN THE PROJECTIONS, AND ARCHITECTURAL DETAILS). MUDD ZONING DISTRICT. MODULATIONS SHALL BE A MINIMUM OF 10 FEET WIDE AND SHALL PROJECT OR RECESS A MINIMUM OF SIX FEET EXTENDING THROUGH THE BUILDING. B.INTERNAL SIDEWALKS AND PEDESTRIAN CONNECTIONS SHALL BE PROVIDED ON THE SITE AS GENERALLY J. BUILDING ELEVATIONS SHALL BE DESIGNED WITH DEPICTED OH THE REZONING PLAN. VERTICAL BAYS OR ARTICULATED ARCHITECTURAL FAQADE FEATURES WHICH MAY INCLUDE BUT NOT BE C. SITE SHALL INCLUDE AN OFFICE SPACE FOR USE LIMITED TO A COMBINATIONPIOF EXTERIOR WALL AS A LEASING AND MANAGEMENT OFFICE. 4 Q OFFSETS, PROJECTIONS, RECESSES, LASTERS, BANDING AND CHANGE IN MATERIALS OR COLORS; 3. A 0 BUILDINGS SHALL BE DESIGNED WITH A RECOGNIZABLE A. VEHICULAR ACCESS WILL BE AS GENERALLY DEPICTED ARCHITECTURAL BASE ON ALL FACADES FACING ON THE REZONING PLAN. THE PLACEMENT AND NETWORK REQUIRED PUBLIC OR PRIVATE STREETS. CONFIGURATION OF THE VEHICULAR ACCESS POINT SUCH BASE MAY BE EXECUTED THROUGH USE OF SHOWN ON THE REZONING PLAN ARE SUBJECT TO PREFERRED EXTERIOR BUILDING MATERIALS OR ANY MINOR MODIFICATIONS REQUIRED TO ARTICULATED ARCHITECTURAL FACADES FEATURES AND ACCOMMODATE FINAL SITE AND CONSTRUCTION PLANS COLOR CHANGES; BUILDING ELEVATIONS FACING AND DESIGNS, AND TO ANY ADJUSTMENTS REQUIRED NETWORK REQUIRED PUBLIC OR PRIVATE STREETS BY CDOT FOR APPROVAL. SHALL NOT HAVE EXPANSES OF BLANK WALLS GREATER THAN 20 FEET IN ALL DIRECTIONS AND B. AS DEPICTED ON THE REZONING PLAN, THE SITE WILL ARCHITECTURAL FEATURES SUCH AS BUT LIMITED TO BE SERVED BY A PRIVATE DRIVEWAY, AND MINOR BANDING, MEDALLIONS OR DESIGN FEATURES OR ADJUSTMENT TO THE LOCATION OF THE DRIVEWAY MATERIALS WILL BE PROVIDED TO AVOID A STERILE, SHALL BE ALLOWED DURING THE CONSTRUCTION UNARTICULATED BLANK TREATMENT OF SUCH WALLS. PERMITTING PROCESS. K. ROOF FORM AND LINES SHALL BE DESIGNED TO C. SUBTERRANEAN PARKING WILL BE PROVIDED TO AVOID THE APPEARANCE OF A LARGE MONOLITHIC EXCEED THE MUDD ZONING ORDINANCE REQUIREMENTS ROOF STRUCTURE AS FOLLOWS: LONG PITCHED OR OF ONE STALL PER RESIDENTIAL UNIT. PETITIONER FLAT ROOF LINES SHALL AVOID CONTINUOUS SHALL PROVIDE 35 PARKING STALLS WITH ADDITIONAL EXPANSES WITHOUT VARIATION BY INCLUDING CHANGES PARKING PROVIDED BY THE USE OF 13 MECHANICAL IN HEIGHT AND/OR ROOF FORM TO INCLUDE BUT NOT LIFTS FOR A TOTAL PARKING CAPABILITY OF 48 BE LIMITED TO GABLES, HIPS, DORMERS OR SPACES. PARAPETS; FOR PITCHED ROOFS THE MINIMUM ALLOWED IS 4:12 EXCLUDING BUILDINGS WITH A FLAT D. SITE SHALL NOT BE REQUIRED TO PROVIDE A 35' BY ROOF AND PARAPET WALLS; ROOF TOP HVAC AND 35' SIGHT TRIANGLE AT THE CORNER OF SEIGLE AND RELATED MECHANICAL EQUIPMENT WILL BE SCREENED 15TH/ ST. FROM PUBLIC VIEW AT GRADE FROM THE NEAREST STREET. E. ALL TRANSPORTATION IMPROVEMENTS WILL BE L. SERVICE AREAS SUCH AS DUMPSTERS, REFUSE AREAS, APPROVED AND CONSTRUCTED BEFORE THE SITE'S RECYCLING AND STORAGE SHALL BE SCREENED FROM FIRST BUILDING CERTIFICATE OF OCCUPANCY IS VIEW WITH MATERIALS AND DESIGN TO BE COMPATIBLE ISSUED. WITH PRINCIPAL STRUCTURES. SUCH DESIGN SHALL F. PETITIONER SHALL REBUILD THE RECEIVING RAMPS AT INCLUDE A MINIMUM 20% PREFERRED EXTERIOR THE CORNER OF SEIGLE AVENUE AND EAST 15TH BUILDING MATERIALS OR A CLASS B BUFFER NOT STREET TO MEET CITY OF CHARLOTTE AND PROWAG LESS THAN 10 FEET IN DEPTH AT ALL ABOVE GRADE PERIMETER NOT PAVED FOR ACCESS. G. PETITIONER SHALL SUPPORT THE RESTRICTION OF M. SIDEWALK EXTENSIONS SHOULD BE PROVIDED ON -STREET PARKING ON 15TH ST. TO ONLY ONE BETWEEN ALL STREET TREES ON ALL PUBLIC AND SIDE OF THE ROAD. IN ACCORDANCE WITH THIS GOAL, PRIVATE NETWORK REQUIRED STREETS WHEN PARKING UNTIL SUCH TIME AS THE PARKING HAS BEEN J RESTRICTED TO ONE SIDE OF THIS BLOCK OF 15TH N. DUMPSTER SHALL BE LOCATED ENCLOSED PARKING AREA ST. PETITIONER SHALL SUPPORT RESTRICTING OF OF THE BUILDING. PROHIBITING PARKING ON ITS 15TH. SITE FRONTAGE. 0 L SUPPORT AND CONTRIBUTE TO THE INSTALLATION OF CROSSWALKS AT THE CORNER OF BELMONT AVE. AND SEIGLE AVE. PER AGREEMENT WITH THE BELMONT COMMUNITY ASSOCIATION. 4. ARCHITECTURAL STANDARDS A. PERMITTED EXTERIOR BUILDING MATERIALS SHALL NOTES 0 SCALE: N.T.S 0 s Planning Department 1:11 U11.41,1Y. APPROVED BY CITY COUNCIL September 16, 2019 F_ P.L. 11 JJJ J JJJJJ J JJ JJJ JJJJJJJJJJJJ JJJ J W JJJJJJ JJJJJJJJJJJ JJJ > JJJ J JJJJJ-JJ+-til �iJ JJJ J JJJJJJJJJJJJJJJJJJ Q JJJ J J JJJJJ JJJJJJ (n f-d", J JJJJJ)JJ J - JJJJJJ JJJJJJJJw N W JJJjjjjjjJJJJJJJJJJ JJJJJJ ~ J J-JJJJJJJJJJJJJJJ F.O.BLDG. J JJJ JJJJJJJJ---JJ---J SHAMROCK DUET 081 -099-1 0 / R5 (_0 / top of creek bank / ICI01 MILDRED & / ELLORENZO DIAGO ®I01 081 -099-1 1 00 R5 30' P.C.C.O Buffer - -� o - \N 0 Lr) 01 C o n ALL TIME FACTORS U)i __ I 081 -099-1 2 ww B 1 D w e0 DQ LL LLI �I R 0 LINE J 167 P.L. M o _ w M D 0 �n 3:Ll 11 0 � w LLJ O QoO� oU— o 00 z U' 10'-0" oQ BUILDING o_ S EPARATI O (E) BACK - OF CURB 0 I 0 c� SITE PLAN CLEAR DRIVEWAY THOMAS & DANIELLE BOONE 081 -099-1 5 R-5 150'-3 1 /2" 10'-0" BUILDING SEPARATION 130'-3" 145'-0" TREE SAVE N43033'22"E-150.2 ' 680 681 682 683 684 685 686 687 11 JJJ- JJJJJ JJJJJJJ JJJJJJJJJJJJ JJJJJJJJ JJJJJ JJJJJ JJJJJ JJJLI JJJ JJJJJJ JJJJJJJJ JJJJJJJJJJJ JJJJJJJ JJJJJ JJJJJ JJJ JJJJ) JJJJJJJ JJJJJJJJJ JJJJJJJJJJJ JJJJJJJJiiJ JJ JJ JJJ JJJ JJJ JJJJJJ -_ J---- --- -- JJ---J - TREE SAVE PCO MITITGATION AREA JJJJJJ-_jj JJJJJ / JJJ JJJ_ JJJJJ JJJJ JJJ JJJJJ (-3407.5 SE� JJJJJ JJJ JJJJ JJJJ JJ JJJJ JJJJ JJJJ JJJJ JJJ JJJ JJJJ JJJ JJJJJJ�JJJJ.JJJJJJ JJJJJJJJJJJJ JJJJJJJJJJJNJJJJ jjI jjI JJ jj JJJJJJ JJJ�JJJJJJJJLJJJJJ *,PRIVATE', , COURTYARD �- 1;230SF�DUMPSTER WWwWW.WWw RECYCLING WW W`WWW W ALLOCATION WWWWW'W'W' < 43'-3" IMEMEM■ MMM��MEN EMEMENEEME NEEMEENIME MEEMMEN MINEINE NE �����MMEE SEIGLE AVENUE ---SALVAT I OEM Y 081 -1 29-07 B-1 R-22 MF 5. OPEN SPACE THE PROJECT WILL MEET OPEN SPACE REQUIRED BY THE ORDINANCE FOR THE MUDD ZONING DISTRICT AS THOSE STANDARDS EXIST AT THE TIME OF THE REZONING APPROVAL OR AT THE TIME OF PERMITTING. A.ENVIRONMENTAL FEATURES I. DEVELOPMENT OF THE SITE SHALL COMPLY WITH CHARLOTTE TREE ORDINANCE. TREE SAVE WILL BE PROVIDED AS GENERALLY DEPICTED ON THE SITE PLAN. II. DEVELOPMENT WITHIN THE SWIM/PCSO BUFFER SHALL BE COORDINATED WITH AND SUBJECT TO APPROVAL BY CHARLOTTE-MECKLENBURG STORM WATER SERVICES AND MITIGATED IF REQUIRED BY CITY ORDINANCE. III.DEVELOPMENT OF THE SITE SHALL COMPLY WITH THE POST CONSTRUCTION ORDINANCE. 1 6. LIGHTING Q A.ALL FREESTANDING LIGHTING FIXTURES INSTALLED ON THE SITE (EXCLUDING LOWER, DECORATIVE LIGHTING THAT MAY BE INSTALLED ALONG THE DRIVEWAYS AND SIDEWALKS AS LANDSCAPING LIGHTING) SHALL BE FULLY CAPPED AND SHIELDED AND THE ILLUMINATION DOWNWARDLY DIRECTED SO THAT DIRECTED ILLUMINATION DOES NOT EXTEND PAST ANY PROPERTY LINE OF THE SITE. B.THE MAXIMUM HEIGHT OF ANY PEDESTRIAN SCALE, FREESTANDING LIGHTING FIXTURE INSTALLED ON THE SITE, INCLUDING ITS BASE, SHALL NOT EXCEED FIFTEEN (15) FEET. C.ANY LIGHTING FIXTURES ATTACHED TO THE BUILDING TO BE CONSTRUCTED ON THE SITE SHALL BE DECORATIVE. CAPPED AND DOWNWARDLY DIRECTED. 20 0 0 75.00 PROPOSED ACCESSIBLE RAMP L. Q0 I N (E) B OF C r P.L. 0' :> PROPOSED ACC SIBLE RAM P �0' X 10' PEDESTRIAN VISIBILITY TRIANGLE 60'-0" (E) R.O.W. 0 5 10 20 SCALE: 1 if 20'-0" cn w o w 0-000 Ln ZM ��o� 0 Q o 0 01 0 8 7. STREETSCAPE AND LANDSCAPING A.PETITIONER SHALL PROVIDE A MINIMUM 8 FEET WIDE SIDEWALK AND A MINIMUM 8 FEET WIDE PLANTING STRIP IN THE SETBACK AS GENERALLY SHOWN ON THE SITE PLAN ON BOTH SEIGLE AVENUE AND 15TH STREET. B.PETITIONER SHALL PROVIDE A SIDEWALK EASEMENT SET AT TWO FEET BEHIND BACK OF SIDEWALK WHERE FEASIBLE, PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 8. AFFORDABLE DWELLING UNIT THREE RESIDENTIAL UNITS WILL BE RESERVED AS AFFORDABLE UNITS. F THE UNITS ARE RENTED THEN THEY WILL BE RENTED AS BELOW MARKET RENTAL UNITS AT A RATE ELIGIBLE FOR THE FEDERAL HOUSING CHOICE VOUCHER PROGRAM. IF THE INDIVIDUAL UNITS ARE SOLD THEN THREE AFFORDABLE UNITS WILL BE SOLD AT 80% AREA MEDIAN INCOME WITH A 10 YEAR RESTRICTION ON THE RESALE OF THE PROPERTY, OR SHALL BE ELIGIBLE FOR THE CITY OF CHARLOTTE'S HOUSE CHARLOTTE PROGRAM. REZONING 9. BINDING EFFECT OF THE REZONING APPLICATION IF THIS REZONING PETITION IS APPROVED, ALL CONDITIONS APPLICABLE TO THE DEVELOPMENT OF THE SITE IMPOSED UNDER - THE REZONING PLAN WILL, UNLESS AMENDED IN THE MANNER SCALE. PROVIDED HEREIN AND UNDER THE ORDINANCE, BE BINDING VICINITY MAP 4 UPON REPRESENTATIVE, SUCCESSORS IN INTEREST OR ASSIGNS. N.T.S 0 SITE DEVELOPMENT DATA: SITE ACREAGE 0.51 ACRES LOT AREA: 22,533 SF TAX PARCEL # 081 -099-1 4 081 -099-1 3 081-099-21 (TRACT 1 ) (TRACT 2) TRACT 3 EXISTING ZONING: R-5 PROPOSED ZONING: MUDD-CD EXISTING USE: SINGLE FAMILY DWELLING PROPOSED USE: MULTIFAMILY DWELLING BUILDING HEIGHT: 44'-0" BUILDING AREA (GROSS): 44,000 SF PROP. FLOOR AREA RATIO: 1.95 DENSITY 56 D.U.A. TOTAL UNITS: 28 RESIDENTIAL UNITS PARKING PROVIDED: 48 35 SPACES 13 HYDRAULIC -LIFT SPACES PARKING RATIO: 313D ALLOCATED 2BD ALLOCATED STACKER 1 BD ALLOCATED PARKING: 2 STALLS PARKING: 1 STALL+ 1 PARKING: 1 STALL TREE SAVE SF: 3,407 SF OPEN SPACE REQUIREMENTS (MUDD-CD): LOT AREA: 22,533 SF OPEN SPACE REQ'D: (1 SF / 150 SF) 22,533 SF / 150 SF = 150.2 SF OPEN SPACE REQ'D OPEN SPACE PROVIDED: 1 ,1 30 SF LEGEND: PROPERTY LINE -x x x - FENCE AND LANDSCAPE SCREENING -------------- TOP OF CREEK BANK 30' P.C.C.O. WITH PROPOSED TREE SAVE AREA. (E) STORMWATER PIPE AND STRUCTURES TO BE RELOCATED. PUBLIC COURTYARD/OPEN SPACE LANDSCAPE STRIP LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL TREE SAVE (TOTAL. 3,407 SF) LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL ® EXISTING TREE TO BE SAVED 0 PROPOSED TREE SITE DATA scnLe: 3 die\\ � ee� CG0\ Erg Avenue Site oe P� e�` Se\��e E oth Stree t z 0 -0 74 SWIFTLEE`)FF1 fk__J- Cfl ti CV ftftftLO N UL a)M O Q O CV M O LL W Uj 0O O O O J>000a) �� w M M cn = co Lo (n co 0- LO 'v— Ln O W 00 W z J w O �--� z V Uj _O Cz (z w U) U o_ REVISED: REZONING SUBMITTAL zh 1 9.03.1 1 0 1 9.06.21 0 1 9.07.09 �\ 1 9.09.17 APPROVAL: STAMP/SEAL: SHEET TITLE: REZONING PLAN PROD. NO: 2018-17 SHEET NO: Al 1 ■ © 2019 SWIFTLEEOFFICE • • • 1W C 0 1 • 2 • 3 • 4 • 15th Street Elevation Scale: 1/8" = V-0" 0 4 8 12 16 FT 5 • • D 1530 Elizabeth Ave, Suite 200 Charlotte NC 28204 704 405 5980 www.cluckdesign.com Offices: CLT / NYC ZLEE KFNNcc EpED ARCy ����9 iT�Ze PRELIMINARY. NOT FOR CONSTRUCTION DESIGN SUBJECT TO DEVELOPMENT CHANGES �oRTH CAftO�`�p ry�RTH CAROP cygRLOTTE'G cy4PLOTTE �G C Submitted: 00/00/00 E 15th St & Seigle Ave Charlotte, NC 28205 prepared for: Harrison Tucker CoHab Development Mark Date Description 01 09/17/2020 Land Development Drawings This Drawing is the property of cluck and is not to be reproduced in whole or in part. It is to be used for the project and site specifically identified herein and is not to be used on any other project. This Drawing is to be returned upon the written request of cluck. Copyright 2019 Cluck Design Collaborative All Rights Reserved. Project name/#: Seigle Ave / 20_102 CAD File Name: 2020_09_17_Seigle Ave_CD.vwx A Exterior Elevations Land Development Review Seigle Ave. Elevation ^' Scale: 1/8" = V-0" 1 0 2 0 4 8 12 16 FT • 3 Il 0 .*i A201 • • • 1W i! 0 1 • 2 • 3 • 4 • 0 4 8 12 16 FT SETBACK R.O.W. Top of Structure Neighbor Side Elevation �, C1 Scale: 1/8" = 1'-0" Top of Grade - 688' n 111 (-4' 6") Average Grade - 684' (-8' 6") Bottomof Grade -680'•�._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._._. \\ 0 4 8 12 16FT Rear Elevation ■ ■ Scale: 1/8" = 1'-0" 0 2 • 3 • SETBACK El 0 5 -0 • • D 1530 Elizabeth Ave, Suite 200 Charlotte NC 28204 704 405 5980 www.cluckdesign.com Offices: CLT / NYC ZLEE KFNNcc EpED ARCy ����9 iT�Ze PRELIMINARY. NOT FOR CONSTRUCTION DESIGN SUBJECT TO DEVELOPMENT CHANGES �oRTH CAftO�`�p ry�RTH CAROP cygRLOTTE'G cy4PLOTTE �G C Submitted: 00/00/00 E 15th St & Seigle Ave Charlotte, NC 28205 prepared for: Harrison Tucker CoHab Development Mark Date Description 01 09/17/2020 Land Development Drawings This Drawing is the property of cluck and is not to be reproduced in whole or in part. It is to be used for the project and site specifically identified herein and is not to be used on any other project. This Drawing is to be returned upon the written request of cluck. Copyright 2019 Cluck Design Collaborative All Rights Reserved. Project name/#: Seigle Ave / 20_102 CAD File Name: 2020_09_17_Seigle Ave_CD.vwx A Exterior Elevations Land Development Review A202 w U 20 • • C Al 0 O N 00 00 00 00 00 L0 ch 00 1 • 2 • 3 • 1 2 3 4 5 6 26'-0" 26'-4" 26'-8" 26'-7" 25'-9" SIDEWALK RAMP. PROVIDE RAILING AS REQUIRED i I I Underground Parking Floor Plan Scale: 1/8" = V-0" 0 4 8 12 16 FT 0 SUMP PUMP TO BE LOCATED UNDER TRASH AREA, REFER PLUMBING ENGINEER ROLL OUT 8 CUBIC YARD TRASH DUMPSTER • (ING GARAGE WITH NATURAL VENTILATION PER SECTION 406.5 0 PROPOSED AREAS HEATED Level 1 Lobby 346.9 Level 1 Apartments 9512.8 PROPOSED HEATED TOTALS 9859.7 UNHEATED Level 1 Circulation 2524.6 PROPOSED UNHEATED TOTAL 2524.6 LEGEND SYMBOL DESCRIPTION / REFERENCE DOOR NUMBER, SEE SCHEDULE, 101A SHEET A002 WINDOW SIZE, SEE SCHEDULE, W-XX SHEET A002 FINISH FLOOR ELEVATION X WALL TYPE, SEE WALL TYPES, SHEET A003 EXISTING WALL PROPOSED WALL, SEE WALL TYPES RATED WALL, SEE SHEET A003 ARCH. GENERAL NOTES 1. TYP. EXTERIOR WALLS ARE 2X4 WOOD FRAME W/ 1/2" EXTERIOR STRUCTURAL PLYWOOD SHEATHING, U.N.O. BY STRUCTURAL DRAWINGS. 2. TYP. INTERIOR PARTITIONS ARE 2X4 WOOD FRAME W/ 1/2" GWB, WALL TYPE 11, U.N.O. 3. ALL EXTERIOR DOORS 8'-0" HEAD HEIGHT, U.N.O. 4. ALL INTERIOR DOORS 6'-8" HEAD HEIGHT, U.N.O. 5. EXTERIOR STAIRS TO BE OPEN AIR CONSTRUCTION 6. EXTERIOR CORRIDORS AND WALKWAYS TO BE OPEN AIR CONSTRUCTION 7. PROVIDE ELECTRICAL OUTLET ON KITCHEN ISLAND PER N.E.C. 210.52 (C2). MEASUREMENT FROM WORK SURFACE TO BOTTOM OF OUTLET SHALL NOT EXCEED 12". OUTLET CANNOT BE INSTALLED UNDER COUNTERTOP OVERHANG MEASURING 6" OR MORE. IDEAL PLACEMENT OF OUTLET IS AT END OF THE KITCHEN ISLAND, OPPOSITE SINKS AND APPLIANCES, BETWEEN LAST CABINET OR DRAWER FACE AND KITCHEN ISLAND CORNER TRIM. 8. PROVIDE REMOVABLE CABINETRY, PROVIDE FLOOR FINSIH BELOW CABINETRY, AND FINISH ALL WALLS BEHIND CABINETRY. 9. DOOR MAY SWING IN CLEAR SPACE PER ANSI 117.1 SECTION 1003.11.2.1 EXCEPTION 1. 10. REFER TO ARCHITECTURAL SITE PLANS - A001 FOR BUILDING LOCATIONS AND UNIT ARRANGEMENT. 11. ALL EXTERIOR DIMENSIONS TAKEN FROM EXTERIOR FACE OF STUD. SIDING WIDTH AND ARCHITECTURAL FEATURES VARY IN WIDTH. REFER TO A201/A202 /A203 / A204 EXTERIOR ELEVATIONS AND A351 WALL SECTIONS FOR SIDING AND ARCHITECTURAL FEATURE DETAILS. 12. ALL INTERIOR DIMENSIONS TAKEN FROM FACE OF STUD. 13. REFER TO STRUCTURAL FOR PLACEMENT AND SIZING OF ALL STRUCTURAL MEMBERS. 14. EXTERIOR WINDOWS BY JELDWEN - 2500 SERIES ALUMINUM CLAD WOOD WINDOWS. 15. SEE A401 FOR TYP. STAIR NOTES AND SECTIONS. 16. ARCHITECT REQUIRES SHEATHING INSPECTION PRIOR TO EXTERIOR SIDING INSTALLATION. SHEATHING INSPECTION TO COVER STRUCTURAL, NON-STRUCTURAL, FIRE SEPARATION, AND MOISTURE AND ENERGY CONSERVATION REQUIREMENTS PRESCRIBED IN THE 2018 NCRC OR BY ENGINEER OR ARCHITECT. • • ❑C 1530 Elizabeth Ave, Suite 200 Charlotte NC 28204 704 405 5980 www.cluckdesign.com Offices: CLT / NYC 1.EE Kf�yNcc `G� COLLABpR ARCy �� �� PRCH IT ECTG 9T� PRELIMINARY. NOT FOR CONSTRUCTION DESIGN SUBJECT TO DEVELOPMENT CHANGES y0 `aP 4,0\"P RTH CAV Off. HTH CAROB' cygRLOTTE �G cygRLOTTE �G C Submitted: 00/00/00 1121 Seigle Ave Charlotte, NC 28205 C prepared for: Harrison Tucker CoHab Development 1918 Beverly Dr. Charlotte, NC 28207 Mark Date Description This Drawing is the property of cluck and is not to be reproduced in whole or in part. It is to be used for the project and site specifically identified herein and is not to be used on any other project. This Drawing is to be returned upon the written request of cluck. Copyright 2019 Cluck Design Collaborative All Rights Reserved. Project name/#: Seigle Ave / 20_102 CAD File Name: 2020_10_26_Seigle Ave_CD.vwx A Underground Parking Floor Plan 2 3 Cl 0 0 Al 01 W U IW C1 A202 • • A Al B 0 O N 00 00 00 00 00 LO M BO 0 1 • 2 • 3 • 4 • 1 2 3 A, 4 5 6 A202 261-011 261-411 261-811 26'-711 251-911 • 3" D • 3 3"W 2"W 3"W 4"W7/7 v � 2" 2' M � 2"W c o "VV 3"W ° cc 0 0 UNIT TYPE 4"RW 1" 0 1 IAIIT TvnC (BELOW) CONCRETE COLUMN -- --- ------------ FOXTROT ° 1 FRo IDS ECHO o LO 1 " IDS LO C o 0 0 11A 0`C5 00 6 0 1" a 0 R 0 0 1 2 3 4 6 6 722 co O O C a® 5'-0" rn Co v 2" o 60 LO M co C 0 - w O 7 co UNIT TYPE ' Cl Al O UNIT TYPE 0 GOLF 1" A301 A301 Zo 0 DELTA _ 0 0 c O o O O ° 0C R 0 4"RW 4"RW /� 9'-2" ° C, DO R 0 o FROM FROM O o 0 IDS IDS v2cm 0- C 0 8 O 2" M 6? - 0 0 5'-0" 0 0 'o � o UNIT TYPE UNIT TYPE FLOOR DRAIN T.O. INTERIOR SLAB1 1 CHARLIE DOWNSPOUT 114'-6" (692.87') 1 SLAB IS LEVEL WITH INTERIOR AT RW 4"RW �0- THRESHOLDS 1 / M FROM FROM �b / rn 11116 17 16 1 220 L 21 22 23 DS DS 00 h-1 rn Al 0 13112 11 10 32 31 30 29 Co 14 27 26 A401 0 � 0 In ® N M UNIT TYPE 15 lZo 34'-11 1/8" 18'-10 1/8" N / BRAVO A402 "' Cl) LOBBY co i I 50'-4" 79'-10 1 /4" ° UNIT TYPE 130'-2 1/4" ° ° o JULIET i 3 c o "W o 0 n WR UNIT TYPE ° 000 i KILO J ° i O i U U O J°� � gc 00 � ogOo oc)o00 UNIT TYPE i )o o °o� c ALPHA i )O�OC )o ()0C O 0 0�°Q FDC Al A201 Cl V 5 • • D 1530 Elizabeth Ave, Suite 200 Charlotte NC 28204 704 405 5980 www.cluckdesign.com Offices: CLT / NYC LEE KFNNcc `G� COLLABpR .� ,�EpED ARCy �� �� PRCH IT ECTG 9Tj PRELIMINARY. NOT FOR CONSTRUCTION DESIGN SUBJECT TO DEVELOPMENT CHANGES �oRTH CAftO�\gyp ry'0" CARO\\"P cygRLOTTE'G cygRLOT-ve �G C Submitted: 00/00/00 1121 Seigle Ave Charlotte, NC 28205 C prepared for: Harrison Tucker CoHab Development 1918 Beverly Dr. Charlotte, NC 28207 Mark Date Description This Drawing is the property of cluck and is not to be reproduced in whole or in part. It is to be used for the project and site specifically identified herein and is not to be used on any other project. This Drawing is to be returned upon the written request of cluck. Copyright 2019 Cluck Design Collaborative All Rights Reserved. Project name/#: Seigle Ave / 20_102 CAD File Name: 2020_10_26_Seigle Ave_CD.vwx A First Floor Edge of Slab Plan Al First Floor Edge of Slab Plan Scale: 1/8" = V-0" 1 0 4 8 12 16 FT ■ ■ . • 2 Kj Cl 0 '67 Al 0201 • C r 7 5 1/2" 1 • 2 • 3 • 4 • 5 ARCH. GENERAL NOTES PROPOSED AREAS 1. TYP. EXTERIOR WALLS ARE 2X4 WOOD FRAME W/ 1/2" HEATED EXTERIOR STRUCTURAL PLYWOOD SHEATHING, Level 1 Lobby 346.9 U.N.O. BY STRUCTURAL DRAWINGS. Level 1 Apartments 9512.8 2. TYP. INTERIOR PARTITIONS ARE 2X4 WOOD FRAME W/ 1/2" GWB, WALL TYPE 11, U.N.O. PROPOSED HEATED TOTALS 9859.7 3. ALL EXTERIOR DOORS 8'-0" HEAD HEIGHT, U.N.O. 51'-6 1/2" 00 21'-10 1/2" 6-6 1 /8" 51'-11 5/8" EXTERIOR REMOVABLE METAL 4. ALL INTERIOR DOORS 6'-8" HEAD HEIGHT, U.N.O. UNHEATED (STAIRS W/ METAL RAILING Level 1 Circulation 2524.6 5. EXTERIOR STAIRS TO BE OPEN AIR CONSTRUCTION / I I 6. EXTERIOR CORRIDORS AND WALKWAYS TO BE OPEN AIR CONSTRUCTION PROPOSED UNHEATED TOTAL 2524.E W-07 W-04 i W-03 W-04 I Ln 7. PROVIDE ELECTRICAL OUTLET ON KITCHEN Lo I oISLAND PER N.E.C. 210.52 (C2). MEASUREMENT FROM moo, O , tf,d o O / I o o-O �� i WORK SURFACE TO BOTTOM OF OUTLET SHALL NOT iu EXCEED 12". OUTLET CANNOT BE INSTALLED UNDER O B-TY0EA i II I `' COUNTERTOP OVERHANG MEASURING 6" OR MORE. IDEAL PLACEMENT OF OUTLET IS AT END OF THE =02 j LEGEND KITCHEN ISLAND, OPPOSITE SINKS AND APPLIANCES,03� I BETWEEN LAST CABINET OR DRAWER FACE AND 0) D01 KITCHEN ISLAND CORNER TRIM. SYMBOL DESCRIPTION / REFERENCE 8. PROVIDE REMOVABLE CABINETRY, PROVIDE FLOORDOOR NUMBER, SEE SCHEDULE, FINSIH BELOW CABINETRY, AND FINISH ALL WALLS 101A SHEETA002 I ,-OP . B - TYI)E e I BEHIND CABINETRY. UNIT TYPE ------ ------V) --- ---- --- �i�� UNIT TYPE EXTERIOR OPEN STAIRCAS I I IWINDOW SIZE, SEE SCHEDULE, �+ 9. DOOR MAY SWING IN CLEAR SPACE PER ANSI 117.1 W-XXD-03FOXTROT - - - - - i (METAL PAN W/ CONCR E -ECHO- - - - - SECTION 1003.11.2.1 EXCEPTION 1. SHEETA002 TRE(D- I 10. REFER TO ARCHITECTURAL SITE PLANS - A001 FOR D- OWNSPOUT - VDOWNSPOUT="--b-0 c i BUILDING LOCATIONS AND UNIT ARRANGEMENT FINISH FLOOR ELEVATION O o , ao El ❑ --- o O • o I I 11. ALL EXTERIOR DIMENSIONS TAKEN FROM EXTERIOR oPY e TvdEg 1 2 3 4 5 6 U i FACE OF STUD. SIDING WIDTH AND < X WALL TYPE, SEE WALL TYPES, SHEET A003 -- ARCHITECTURAL FEATURES VARY IN WIDTH. REFER X D-oz I - � � TO A201/A202 /A203 / A204 EXTERIOR ELEVATIONS _Jlull I' 03 i ; ih _ i i AND A351 WALL SECTIONS FOR SIDING AND EXISTING WALL ARCHITECTURAL FEATURE DETAILS. o- o2. ALL INTERIOR DIMENSIONS TAKEN FROM FACE OF coM � � I STUD. PROPOSED WALL, SEE WALL TYPES i UNIT TYPE I C1 Al I D-o2 o�12 I UNIT TYPE d 50 � I 13. REFER TO STRUCTURAL FOR PLACEMENT GOLF I i A301 A301 i I ❑ I DELTA I AND SIZING OF ALL STRUCTURAL MEMBERS. RATED WALL, SEE SHEETA003 D-03 i ❑ I I I I O D- D- I i o o I I o 14. EXTERIOR WINDOWS BY JELDWEN - 2500 i SERIES ALUMINUM CLAD WOOD WINDOWS. TYPICAL UNIT FINISHES I ------- 00 ------- I I ---- 00 ,------- --- N i 15. SEE A401 FOR TYP. STAIR NOTES AND SECTIONS. O OWNSPOUT _ Q oPY.e -TvdEg ' I I o oPY.e-TY)EB ' I 16. ARCHITECT REQUIRES SHEATHING INSPECTION ONE BEDROOM AFFORDABLE UNITS DOWNSPOUT �• o, I 1. LVT FLOORING "EXCEPT AT LEVEL 1 TO BE SEALED - PRIOR TO EXTERIOR SIDING INSTALLATION. D-02 I I I D-01 I - -------------------- .--- - ------ ------ ----- - - - - - - - -------------- -- - SHEATHING INSPECTION TO COVER STRUCTURAL, CONCRETE) 03 I NON-STRUCTURAL, FIRE SEPARATION, AND 2. LVT FLOORING IN BATHROOM MOISTURE AND ENERGY CONSERVATION 3. LVT IN BEDROOM D_ I I I REQUIREMENTS PRESCRIBED IN THE 2018 NCRC OR 4. 1X6 BASEBOARDS BY ENGINEER OR ARCHITECT. 5. TRIMLESS DOORS / WINDOWS �D I� 03 I `° 6. VINYL WINDOWS IX 00 7. HOLLOW METAL DOORS UNIT TYPE UNIT TYPE 8. WIRE SHELVING IN CLOSETS I 9. PAINTED DRYWALL EVERYWHERE (INCLUDING INDIA CHARLIE BATHROOM) EXTERIOR CONCRETE EGRESS RAMP W/ METAL RAILING 132'-4 1 /4" OVERALL Al A202 EXTERIOR OPEN STAIRCASE (METAL PAN W/ CONCRETE TREADS) CONCRETE FINISH ON LEVEL 1 COURTYARD, TYPICAL 1 HOUR WALL ASSEMBLY REQUIRED BETWEEN ALL RESIDENTIAL UNITS, SEE SHEET G005 FOR ASSEMBLY DETAILS ao J w o D-03 I I D- Cl)Q 10. FIBERGLASS TUB/SHOWER SURROUND • o w - - - - - - - - - - - - I` - - - - - - - - - - I - I - - - - - - - -I - - - - - - - - - - ❑ ❑ - I - - w Of 11. SOLID SURFACE COUNTERTOPS (KITCHEN &BATH) > - 1 - - D 01 i;o > 12. PAINTED CABINETRY 0 w-10 i O 13. APARTMENT GRADE FIXTURES C1 14. APARTMENT GRADE APPLIANCES C1 n I`\ EGRESS LANDING D :M _J I I I I o 0 2' 0 77/8" i 15. APARTMENT GRADE LIGHTING A202 �r EXTERIOR OPEN STAIRCASE - 1,06'=2"(68654') 5 16 17 ,6 ,9 20 21 22 23 24 25 I I A201 Cl) (METAL PAN W/ CONCRETE ) I _ OWNSPOUT _ _ DOWNSPOUT�o I I 16. 42" MIRROR IN BATHROOM o ) I I A4o1 �; 69287 AR I D-.1 TYPICAL UNITS TREADS I M U I PODIUMS 14 ,3 ,2 „ ,6 32 3, 30 29 26 27 26 W 12 w 1z W-1z I I I EXTERIOR REMOVABLE METAL 1. ENGINEERED HARDWOOD FLOORING ("EXCEPT AT ---------- --- I O B-TYPES ' I � - LEVEL 1 TO BE SEALED CONCRETE) D-13-I,.,°� ❑ - UNIT TYPE I STAIRS W/ METAL RAILING 2. TILE FLOORING IN BATHROOM D-02 I 0 • C 0 METAL EGRESS GATE 15 I A3 I I I 3. ENGINEERED HARDWOOD FLOORING IN BEDROOM LO (PROVIDE PANIC HARDWARE) I RISERT I o A402 LOBBY BRAVO 4. RBASEBOARDS • o RISER ROOM L\T.O.PODIUMSI I I 5. TIMLESSDOORS/WINDOWS ROOM � RISER ROOM V LAB 6. WIRE SHELVING IN CLOSETS 00 I I (692.87'F I D-01 -01 03 D-01 7. PAINTED DRYWALL - - - - - - - - - - - - - - - - - - IF= - - - - - - - - - - - - - - . - - . - - - - - - - - 8. TILE IN SHOWER & WET WALLS (OR, FIBERGLASS 7t N i I O o I N I W-12 W-1z 3 W-1z SHOWER PAN & TILE ON WET WALLS) m 9. GLASS SHOWER o O �J 13'-4 5/8" 12'-7 3/8" D-03 ❑ i 10. FIBERGLASS TUB/SHOWER SURROUND (SECONDARY '` CONCR TE COLUMN, 4 0? T.O.ENTRY RAMP � I c I BATHROOMS) 0JI I� I'-6'69287 11. QUARTZ COUNTERTOPS NTERTOPS ROUND UNIT TYPE M -O-O-� - o------- O o = 12. PAINTED CABINETRY JI�I JULIET ! ,� I I 13. UPGRADED FIXTURES I �,, � I I � I co 14. UPGRADED LIGHTING CONCRETE COLUMNS, T.O. STUDIO UNIT O o 15. STAINLESS STEEL APPLIANCES TYPICAL SLAB > � co CONCRETE DRIVEWAY \per �ENZRYRZM(693DI)NG I N ACCESSIBLE UNIT NOTES i o 0 15fl-os) � m � �01 o `., _ 1. 5%, BUT NOT LESS THAN 1 UNIT ARE REQUIRED BE I� �o UNIT TYPE ------ m N CONCRETE RETAINING �l0 o TYPE A UNITS WALL TYPICAL KILO - - JI_ - 00 2. ALL UNITS NOT REQUIRED TO BE TYPE A UNITS ARE BETWEEN DRIVEWAY EGRESS RAMP AND CONCRETE LANDING SIDEWALK PEDESTRIAN 09 812"(666.06') RAMP CLR.•Ff CONCRETE STEPPED SIDEWALK RAMP. Oo - o ENTRY RAMP LANDINGhF -- - - O o -_r o O co -- o ---O� --- �' O CD oC W07 ��'L? TOSTUDIO UNI�o C CONCRETE 0? CONCRETE TYPE c6soo4') .. T - - - SLAB o o-sTueIGSN-LAIB O� O < STEPPED ENTRY PROVIDE RAILING AS O �111'-8"(690.04') ODc RAMP. PROVIDE REQUIRED 1 P SIDEWALK GRADE W_08 W-0 W-08 / (689.901) •' 12'-6 1/2" 5'-1 1 /8" 5 1/2" -1- 30'-4 5/8" /1 V-2 7/8" _ 17'-7 5/8" CONCRETE RAMP W/ METAL RAILING M Q ')0" o o RAILING AS ALPHA 000 oC REQUIRED M 0 O N 0 STEPPING o C3°� STONE it WALKWAY N SIDEWALK GRADE 689.49') 4'-5 1/2" 4'-8 1/2" 26'-0" 129'-8" OVERALL Al A201 N aQ REQUIRED TO BE TYPE B UNITS D-03 3. BOTH TYPE A AND TYPE B UNITS REQUIRE ACCESSIBILITY FEATURES IN BEDROOM, BATHROOM, KITCHEN, AND LAUNDRY AREAS. o 3 iv 4. ADA accessible plumbing fixtures 5. ADA accessible grab bars 00 6. ADA accessible shower D-03 ' 7. ADA accessible counter/cabinet heights (kitchen / bathroom) 8. ADA accessible appliances 9. ADA accessible hardware and door pulls 10. 3'-0" Interior and Exterior Doors 00 10'-8 1/2" 4'-8 1 /2" 10'-8 1/2" 38'-11 1/2" I _4'-11 7/8" _ • • • C 1530 Elizabeth Ave, Suite 200 Charlotte NC 28204 704 405 5980 www.cluckdesign.com Offices: CLT / NYC ��`N LEE Kf�yNcc `G� COLLABpR .� ,�EpED ARCy �� �� PRCH IT ECTG 9T� PRELIMINARY. NOT FOR CONSTRUCTION DESIGN SUBJECT TO DEVELOPMENT CHANGES �o?PH CAftOry�ATH CA100) P cygRLOTTE 'k cygRLOTTE 'k Submitted: 00/00/00 1121 Seigle Ave Charlotte, NC 28205 prepared for: Harrison Tucker CoHab Development 1918 Beverly Dr. Charlotte, NC 28207 Mark Date Description FOXTROT ECHO GOLF ❑ DELTA INDIA ❑ CHARLIE JULIET ALPHA BRA KILO KEY PLAN LEVEL 1 This Drawing is the property of cluck and is not to be reproduced in whole or in part. It is to be used for the project and site specifically identified herein and is not to be used on any other project. This Drawing is to be returned upon the written request of cluck. Copyright 2019 Cluck Design Collaborative All Rights Reserved. Project name/#: Seigle Ave / 20_102 CAD File Name: 2020_10_26_Seigle Ave_CD.vwx First Floor Floor Plan Al First Floor Floor Plan Scale: 1/8" = 1'-011 1 • 0 4 8 12 16 FT 2 • K3 • CI • 0 A102.2 • • X C C 0 1 1 Second Floor Floor Plan Al Scale: 1/8" = 1'-0" 1 • 2 0 4 8 12 16 FT Al A202 A201 • 3 • 0 CENTERLINE OF WINDOW ALIGNS WITH CENTERLINE OF WINDOW BELOW, TYP. SEE ELEVATIONS FOR REFERENCE. • TYPICAL UNIT FINISHES ONE BEDROOM AFFORDABLE UNITS 1. LVT FLOORING (""EXCEPT AT LEVEL 1 TO BE SEALED CONCRETE) 2. LVT FLOORING IN BATHROOM 3. LVT IN BEDROOM 4. 1X6 BASEBOARDS 5. TRIMLESS DOORS / WINDOWS 6. VINYL WINDOWS 7. HOLLOW METAL DOORS 8. WIRE SHELVING IN CLOSETS 9. PAINTED DRYWALL EVERYWHERE (INCLUDING BATHROOM) 10. FIBERGLASS TUB/SHOWER SURROUND 11. SOLID SURFACE COUNTERTOPS (KITCHEN & BATH) 12. PAINTED CABINETRY 13. APARTMENT GRADE FIXTURES 14. APARTMENT GRADE APPLIANCES 15. APARTMENT GRADE LIGHTING 16. 42" MIRROR IN BATHROOM TYPICAL UNITS 1. ENGINEERED HARDWOOD FLOORING (""EXCEPT AT LEVEL 1 TO BE SEALED CONCRETE) 2. TILE FLOORING IN BATHROOM 3. ENGINEERED HARDWOOD FLOORING IN BEDROOM 4. 1X6 BASEBOARDS 5. TRIMLESS DOORS / WINDOWS 6. WIRE SHELVING IN CLOSETS 7. PAINTED DRYWALL 8. TILE IN SHOWER & WET WALLS (OR, FIBERGLASS SHOWER PAN & TILE ON WET WALLS) 9. GLASS SHOWER 10. FIBERGLASS TUB/SHOWER SURROUND (SECONDARY BATHROOMS) 11. QUARTZ COUNTERTOPS 12. PAINTED CABINETRY 13. UPGRADED FIXTURES 14. UPGRADED LIGHTING 15. STAINLESS STEEL APPLIANCES 0 PROPOSED AREAS HEATED Level 1 Lobby 346.9 Level 1 Apartments 9512.8 PROPOSED HEATED TOTALS 9859.7 UNHEATED Level 1 Circulation 2524.6 PROPOSED UNHEATED TOTAL 2524.6 LEGEND SYMBOL DESCRIPTION / REFERENCE DOOR NUMBER, SEE SCHEDULE, 101A SHEET A002 WINDOW SIZE, SEE SCHEDULE, W-XX SHEET A002 FINISH FLOOR ELEVATION X WALL TYPE, SEE WALL TYPES, SHEET A003 EXISTING WALL PROPOSED WALL, SEE WALL TYPES RATED WALL, SEE SHEET A003 ARCH. GENERAL NOTES 1. TYP. EXTERIOR WALLS ARE 2X4 WOOD FRAME W/ 1/2" EXTERIOR STRUCTURAL PLYWOOD SHEATHING, U.N.O. BY STRUCTURAL DRAWINGS. 2. TYP. INTERIOR PARTITIONS ARE 2X4 WOOD FRAME W/ 1/2" GWB, WALL TYPE 11, U.N.O. 3. ALL EXTERIOR DOORS 8'-0" HEAD HEIGHT, U.N.O. 4. ALL INTERIOR DOORS 6'-8" HEAD HEIGHT, U.N.O. 5. EXTERIOR STAIRS TO BE OPEN AIR CONSTRUCTION 6. EXTERIOR CORRIDORS AND WALKWAYS TO BE OPEN AIR CONSTRUCTION 7. PROVIDE ELECTRICAL OUTLET ON KITCHEN ISLAND PER N.E.C. 210.52 (C2). MEASUREMENT FROM WORK SURFACE TO BOTTOM OF OUTLET SHALL NOT EXCEED 12". OUTLET CANNOT BE INSTALLED UNDER COUNTERTOP OVERHANG MEASURING 6" OR MORE. IDEAL PLACEMENT OF OUTLET IS AT END OF THE KITCHEN ISLAND, OPPOSITE SINKS AND APPLIANCES, BETWEEN LAST CABINET OR DRAWER FACE AND KITCHEN ISLAND CORNER TRIM. 8. PROVIDE REMOVABLE CABINETRY, PROVIDE FLOOR FINSIH BELOW CABINETRY, AND FINISH ALL WALLS BEHIND CABINETRY. 9. DOOR MAY SWING IN CLEAR SPACE PER ANSI 117.1 SECTION 1003.11.2.1 EXCEPTION 1. 10. REFER TO ARCHITECTURAL SITE PLANS - A001 FOR BUILDING LOCATIONS AND UNIT ARRANGEMENT. 11. ALL EXTERIOR DIMENSIONS TAKEN FROM EXTERIOR FACE OF STUD. SIDING WIDTH AND ARCHITECTURAL FEATURES VARY IN WIDTH. REFER TO A201/A202 /A203 / A204 EXTERIOR ELEVATIONS AND A351 WALL SECTIONS FOR SIDING AND ARCHITECTURAL FEATURE DETAILS. 12. ALL INTERIOR DIMENSIONS TAKEN FROM FACE OF STUD. 13. REFER TO STRUCTURAL FOR PLACEMENT AND SIZING OF ALL STRUCTURAL MEMBERS. 14. EXTERIOR WINDOWS BY JELDWEN - 2500 SERIES ALUMINUM CLAD WOOD WINDOWS. 15. SEE A401 FOR TYP. STAIR NOTES AND SECTIONS. 16. ARCHITECT REQUIRES SHEATHING INSPECTION PRIOR TO EXTERIOR SIDING INSTALLATION. SHEATHING INSPECTION TO COVER STRUCTURAL, NON-STRUCTURAL, FIRE SEPARATION, AND MOISTURE AND ENERGY CONSERVATION REQUIREMENTS PRESCRIBED IN THE 2018 NCRC OR BY ENGINEER OR ARCHITECT. ACCESSIBLE UNIT NOTES 1. 5%, BUT NOT LESS THAN 1 UNIT ARE REQUIRED BE TYPE A UNITS 2. ALL UNITS NOT REQUIRED TO BE TYPE A UNITS ARE REQUIRED TO BE TYPE B UNITS 3. BOTH TYPE A AND TYPE B UNITS REQUIRE ACCESSIBILITY FEATURES IN BEDROOM, BATHROOM, KITCHEN, AND LAUNDRY AREAS. 4. ADA accessible plumbing fixtures 5. ADA accessible grab bars 6. ADA accessible shower 7. ADA accessible counter/cabinet heights (kitchen / bathroom) 8. ADA accessible appliances 9. ADA accessible hardware and door pulls 10. 3'-0" Interior and Exterior Doors • • ❑C 1530 Elizabeth Ave, Suite 200 Charlotte NC 28204 704 405 5980 www.cluckdesign.com Offices: CLT / NYC 1.EE F(ENNF ��� COLLABpR �EpED ARCH �� �� PRCH IT ECTG 9�j PRELIMINARY. NOT FOR CONSTRUCTION DESIGN SUBJECT TO DEVELOPMENT CHANGES ~oRTN CA0.��'\�P ry0' CARD�'`�P cygRLOTTE �G cy4P 0T.TS �/ C Submitted: 00/00/00 1121 Seigle Ave Charlotte, NC 28205 prepared for: Harrison Tucker CoHab Development 1918 Beverly Dr. Charlotte, NC 28207 Mark Date Description FOXTROT I NOVEMBER B GOLF MIKE INDIA LIMA 01 s :'9 X91 OSCAR KEY PLAN LEVEL 2 & 3 This Drawing is the property of cluck and is not to be reproduced in whole or in part. It is to be used for the project and site specifically identified herein and is not to be used on any other project. This Drawing is to be returned upon the written request of cluck. Copyright 2019 Cluck Design Collaborative All Rights Reserved. Project name/#: Seigle Ave / 20_102 CAD File Name: 2020_10_26_Seigle Ave_CD.vwx Second Floor Floor Plan 0 2 K3 M 0 0 A103 • • X C C 0 1 Al Third Floor Floor Plan Scale: 1/8" = 1'-0" 1 • 2 0 4 8 12 16 FT ■ ■ Al A202 A201 • 3 • 0 CENTERLINE OF WINDOW ALIGNS WITH CENTERLINE OF WINDOW BELOW, TYP. SEE ELEVATIONS FOR REFERENCE. • TYPICAL UNIT FINISHES ONE BEDROOM AFFORDABLE UNITS 1. LVT FLOORING (""EXCEPT AT LEVEL 1 TO BE SEALED CONCRETE) 2. LVT FLOORING IN BATHROOM 3. LVT IN BEDROOM 4. 1X6 BASEBOARDS 5. TRIMLESS DOORS / WINDOWS 6. VINYL WINDOWS 7. HOLLOW METAL DOORS 8. WIRE SHELVING IN CLOSETS 9. PAINTED DRYWALL EVERYWHERE (INCLUDING BATHROOM) 10. FIBERGLASS TUB/SHOWER SURROUND 11. SOLID SURFACE COUNTERTOPS (KITCHEN & BATH) 12. PAINTED CABINETRY 13. APARTMENT GRADE FIXTURES 14. APARTMENT GRADE APPLIANCES 15. APARTMENT GRADE LIGHTING 16. 42" MIRROR IN BATHROOM TYPICAL UNITS 1. ENGINEERED HARDWOOD FLOORING (""EXCEPT AT LEVEL 1 TO BE SEALED CONCRETE) 2. TILE FLOORING IN BATHROOM 3. ENGINEERED HARDWOOD FLOORING IN BEDROOM 4. 1X6 BASEBOARDS 5. TRIMLESS DOORS / WINDOWS 6. WIRE SHELVING IN CLOSETS 7. PAINTED DRYWALL 8. TILE IN SHOWER & WET WALLS (OR, FIBERGLASS SHOWER PAN & TILE ON WET WALLS) 9. GLASS SHOWER 10. FIBERGLASS TUB/SHOWER SURROUND (SECONDARY BATHROOMS) 11. QUARTZ COUNTERTOPS 12. PAINTED CABINETRY 13. UPGRADED FIXTURES 14. UPGRADED LIGHTING 15. STAINLESS STEEL APPLIANCES 0 PROPOSED AREAS HEATED Level 1 Lobby 346.9 Level 1 Apartments 9512.8 PROPOSED HEATED TOTALS 9859.7 UNHEATED Level 1 Circulation 2524.6 PROPOSED UNHEATED TOTAL 2524.6 LEGEND SYMBOL DESCRIPTION / REFERENCE DOOR NUMBER, SEE SCHEDULE, 101A SHEET A002 WINDOW SIZE, SEE SCHEDULE, W-XX SHEET A002 FINISH FLOOR ELEVATION X WALL TYPE, SEE WALL TYPES, SHEET A003 EXISTING WALL PROPOSED WALL, SEE WALL TYPES RATED WALL, SEE SHEET A003 ARCH. GENERAL NOTES 1. TYP. EXTERIOR WALLS ARE 2X4 WOOD FRAME W/ 1/2" EXTERIOR STRUCTURAL PLYWOOD SHEATHING, U.N.O. BY STRUCTURAL DRAWINGS. 2. TYP. INTERIOR PARTITIONS ARE 2X4 WOOD FRAME W/ 1/2" GWB, WALL TYPE 11, U.N.O. 3. ALL EXTERIOR DOORS 8'-0" HEAD HEIGHT, U.N.O. 4. ALL INTERIOR DOORS 6'-8" HEAD HEIGHT, U.N.O. 5. EXTERIOR STAIRS TO BE OPEN AIR CONSTRUCTION 6. EXTERIOR CORRIDORS AND WALKWAYS TO BE OPEN AIR CONSTRUCTION 7. PROVIDE ELECTRICAL OUTLET ON KITCHEN ISLAND PER N.E.C. 210.52 (C2). MEASUREMENT FROM WORK SURFACE TO BOTTOM OF OUTLET SHALL NOT EXCEED 12". OUTLET CANNOT BE INSTALLED UNDER COUNTERTOP OVERHANG MEASURING 6" OR MORE. IDEAL PLACEMENT OF OUTLET IS AT END OF THE KITCHEN ISLAND, OPPOSITE SINKS AND APPLIANCES, BETWEEN LAST CABINET OR DRAWER FACE AND KITCHEN ISLAND CORNER TRIM. 8. PROVIDE REMOVABLE CABINETRY, PROVIDE FLOOR FINSIH BELOW CABINETRY, AND FINISH ALL WALLS BEHIND CABINETRY. 9. DOOR MAY SWING IN CLEAR SPACE PER ANSI 117.1 SECTION 1003.11.2.1 EXCEPTION 1. 10. REFER TO ARCHITECTURAL SITE PLANS - A001 FOR BUILDING LOCATIONS AND UNIT ARRANGEMENT. 11. ALL EXTERIOR DIMENSIONS TAKEN FROM EXTERIOR FACE OF STUD. SIDING WIDTH AND ARCHITECTURAL FEATURES VARY IN WIDTH. REFER TO A201/A202 /A203 / A204 EXTERIOR ELEVATIONS AND A351 WALL SECTIONS FOR SIDING AND ARCHITECTURAL FEATURE DETAILS. 12. ALL INTERIOR DIMENSIONS TAKEN FROM FACE OF STUD. 13. REFER TO STRUCTURAL FOR PLACEMENT AND SIZING OF ALL STRUCTURAL MEMBERS. 14. EXTERIOR WINDOWS BY JELDWEN - 2500 SERIES ALUMINUM CLAD WOOD WINDOWS. 15. SEE A401 FOR TYP. STAIR NOTES AND SECTIONS. 16. ARCHITECT REQUIRES SHEATHING INSPECTION PRIOR TO EXTERIOR SIDING INSTALLATION. SHEATHING INSPECTION TO COVER STRUCTURAL, NON-STRUCTURAL, FIRE SEPARATION, AND MOISTURE AND ENERGY CONSERVATION REQUIREMENTS PRESCRIBED IN THE 2018 NCRC OR BY ENGINEER OR ARCHITECT. ACCESSIBLE UNIT NOTES 1. 5%, BUT NOT LESS THAN 1 UNIT ARE REQUIRED BE TYPE A UNITS 2. ALL UNITS NOT REQUIRED TO BE TYPE A UNITS ARE REQUIRED TO BE TYPE B UNITS 3. BOTH TYPE A AND TYPE B UNITS REQUIRE ACCESSIBILITY FEATURES IN BEDROOM, BATHROOM, KITCHEN, AND LAUNDRY AREAS. 4. ADA accessible plumbing fixtures 5. ADA accessible grab bars 6. ADA accessible shower 7. ADA accessible counter/cabinet heights (kitchen / bathroom) 8. ADA accessible appliances 9. ADA accessible hardware and door pulls 10. 3'-0" Interior and Exterior Doors • • ❑C 1530 Elizabeth Ave, Suite 200 Charlotte NC 28204 704 405 5980 www.cluckdesign.com Offices: CLT / NYC E f�yfI-E 11KO� �� PRGH IT E�TG qjj PRELIMINARY. NOT FOR CONSTRUCTION DESIGN SUBJECT TO DEVELOPMENT CHANGES �oRTH CAftO�`ap ry�ATH CARO�'\�P cygRLOTTE �G cygRLOTTE C Submitted: 00/00/00 1121 Seigle Ave Charlotte, NC 28205 prepared for: Harrison Tucker CoHab Development 1918 Beverly Dr. Charlotte, NC 28207 Mark Date Description FOXTROT I NOVEMBER B GOLF MIKE INDIA LIMA 01 s :'9 X91 OSCAR KEY PLAN LEVEL 2 & 3 This Drawing is the property of cluck and is not to be reproduced in whole or in part. It is to be used for the project and site specifically identified herein and is not to be used on any other project. This Drawing is to be returned upon the written request of cluck. Copyright 2019 Cluck Design Collaborative All Rights Reserved. Project name/#: Seigle Ave / 20_102 CAD File Name: 2020_10_26_Seigle Ave_CD.vwx Third Floor Floor Plan K3 M 0 0 A104 Please post this sign on a window so that it is visible from the street. Failure to do so may delay inspections. For inspections call (704) 336-8000 Mecklenburg County Building Document Permit No: B3870123 Lien Agent Issued Date: 1/15/2021 Contractor: KELLY MCARDLE CONSTRUCTION LLC Parcel No: 08109921 Lien Agent No: Address: 820 E 15TH ST SCOPE OF WORK Project Name (Description of Work) TOTAL RES DEMO-HOUSEDemolish/Move Off. SF Dwelling Detached. EXPANDED SCOPE OF WORK Demolition of existing building Wednesday, February 3, 2021 Page 1 of 2 Inspection Approvals Inspector Signature and Date of Approval where applicable This page is for one and two family projects only including townhouses Page must be posted on site and accessible Building TOTAL RES DEMO -HOUSE im B3870123 FT: SL: FIR: FI: FD: MS: IN: Contractor should always verify each required inspection result from their dashboard before proceeding, for more information on your project, scan the respective QR code above. Wednesday, February 3, 2021 Page 2 of 2 Please post this sign on a window so that it is visible from the street. Failure to do so may delay inspections. For inspections call (704) 336-8000 Mecklenburg County Building Document Permit No: B3870141 Issued Date: 1/15/2021 Contractor: KELLY MCARDLE CONSTRUCTION LLC Parcel No: 08109913 Address: 1113 SEIGLE AVE Lien Agent Lien Agent No: SCOPE OF WORK Project Name (Description of Work) TOTAL RES DEMO-HOUSEDemolish/Move Off. SF Dwelling Detached. EXPANDED SCOPE OF WORK Demolition of detached house and demolition of detached garage Wednesday, February 3, 2021 Page 1 of 2 Inspection Approvals Inspector Signature and Date of Approval where applicable This page is for one and two family projects only including townhouses Page must be posted on site and accessible Building TOTAL RES DEMO -GARAGE B3897016 FT: SL: FIR: FI: FD: MS: IN: Building TOTAL RES DEMO -HOUSE B3870141 FT: SL: FIR: FI: FD: MS: IN: Contractor should always verify each required inspection result from their dashboard before proceeding, for more information on your project, scan the respective QR code above. Wednesday, February 3, 2021 Page 2 of 2 Please post this sign on a window so that it is visible from the street. Failure to do so may delay inspections. For inspections call (704) 336-8000 Mecklenburg County Building Document Permit No: B3897016 Issued Date: 1/15/2021 Contractor: KELLY MCARDLE CONSTRUCTION LLC Parcel No: 08109913 Address: 1113 SEIGLE AVE Lien Agent Lien Agent No: SCOPE OF WORK Project Name (Description of Work) TOTAL RES DEMO -GARAGE EXPANDED SCOPE OF WORK Wednesday, February 3, 2021 Page 1 of 2 Inspection Approvals Inspector Signature and Date of Approval where applicable This page is for one and two family projects only including townhouses Page must be posted on site and accessible Building TOTAL RES DEMO -GARAGE B3897016 FT: SL: FIR: FI: FD: MS: IN: Building TOTAL RES DEMO -HOUSE B3870141 FT: SL: FIR: FI: FD: MS: IN: Contractor should always verify each required inspection result from their dashboard before proceeding, for more information on your project, scan the respective QR code above. Wednesday, February 3, 2021 Page 2 of 2 Please post this sign on a window so that it is visible from the street. Failure to do so may delay inspections. For inspections call (704) 336-8000 Mecklenburg County Building Document Permit No: B3870135 Issued Date: 1/15/2021 Contractor: KELLY MCARDLE CONSTRUCTION LLC Parcel No: 08109914 Address: 1121 SEIGLE AVE Lien Agent Lien Agent No: SCOPE OF WORK Project Name (Description of Work) TOTAL RES DEMO-HOUSEDemolish/Move Off. SF Dwelling Detached. EXPANDED SCOPE OF WORK Demolition of existing house Wednesday, February 3, 2021 Page 1 of 2 Inspection Approvals Inspector Signature and Date of Approval where applicable This page is for one and two family projects only including townhouses Page must be posted on site and accessible Building TOTAL RES DEMO -HOUSE B3870135 4 FT: SL: FIR: FI: FD: MS: IN: Contractor should always verify each required inspection result from their dashboard before proceeding, for more information on your project, scan the respective QR code above. Wednesday, February 3, 2021 Page 2 of 2 Appendix B Preliminary Construction Schedule hart hickman SMARTER ENVIRONMENTAL SOLUTIONS Task Site work/Excavation of Parking Garage Column Footings well Footings Elevator Pit Concrete walls Columns Podium Slab Podium Slab Strength Strip Podium Slab Forms Basement Slab on Grade Footings on grade Foundation on grade Plumb Slab Slab on Grade Framing Plumbing Rough HVAC Rough Elecrical Rough Fire Alarm Sprinklers Inspections sulat Above Ceiling Sheetrack Gyperete Cabinets Interior Trim Interior Paint Countertops Specialties, Hardware, Mirrors, Shelving Plumbing Trim HVACTnm Electrical Trim Trade Inspections Flooring Sprinkler/Fire Alarm Punch/Clean Up Building Final Landscaping Co o©©o©0000mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmommmommmommmmmmmmmmmmmmmmmmmm gawl.awlli Appendix C Cut -Fill Analysis hart hickman SMARTER ENVIRONMENTAL SOLUTIONS Elevations Table Number Minimum Elevation Maximum Elevation Color 1 —9.688 —4.630 2 —4.630 —1.000 3 —1.000 —0.332 4 —0.332 —0.003 5 —0.003 0.132 _ 6 0.132 0.718 7 0.718 1.914 g 1.914 7.527 MEH Information I Definition I Analysis Statistics 1 statistics p+ General S TIN (D Volurne _ Base Surface Comparison Surface Cut Factor Fill Factor Cut volume (adjusted) Fill volume (adjusted) Net volume (adjusted) Cut volume {unadjusted) Fill volume (unadjusted) Net volume (unadjusted) Value 19-133 EG 19-133 FG 1.000 1.150 2186.79 Cu, Yd. 639.90 Cu. Yd, 1547.00 Cu, Yd.tCut> 2186.79 Cu, Yd. 556,34 Cu. Yd. 1630.45 Cu. Yd.4 Cuts