HomeMy WebLinkAbout19038_Dunavant Street_SIR_20220818
DWM Brownfields Inspection Report
Submitted By: jkslaughter_ncdenr
Submitted Time: 08/19/2022 8:33 AM
I. Inspection Information
Date & Time: 08/18/2022 12:15 PM Inspection Type: Drive-By
Brownfields Staff:
Kevin Slaughter
Other Personnel:
N/A
Location:
Lat: 35.20802722, Long: -80.86651466
Brownfields Inspection Report: Dunavant Street, 19038-15-060
08/18/2022 12:15 PM
Page 2 of 5
II. Project Information
Number: 19038-15-060 Name: Dunavant Street
Address: 2115, 2135, 2205
Dunavant Street
City: Charlotte
County: Mecklenburg
III. Environmental
Current Use of Property: Commercial/Retail
Structures on Property: Existing Structures Violation: No
Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No
Use of Surface Water or Groundwater: Not Observed Water Use Violation: No
Exposed Soils: Not Observed Exposed Soils Violation: No
Summary: Stego-Wrap vapor barrier visible through windows of future tenant space
(Photos 1-3). Unable to closely inspect barrier as there was no one in the space by the
time I arrived onsite, however, the sections of barrier, seams, terminations at columns,
and at the surrounding concrete slab appeared to be in good condition. Stego Mastic had
been used in addition to double-sided Stego Tack tape which alone is an acceptable
method of sealing the VIMS barrier to concrete according to the manufacturer.
Summary: N/A
Summary: Newer building with future tenant space on ground floor, and residential
apartments on upper floors.
Summary: N/A
Brownfields Inspection Report: Dunavant Street, 19038-15-060
08/18/2022 12:15 PM
Page 3 of 5
Use of Basements: Not Observed Basement Violation: No
Storage of Chemicals: Not Observed Chemical Violation: No
Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No
Current Exposure to Public/Public Risk:
Summary: N/A
Summary: N/A
Condition:
Summary: N/A
No risk to the public observed at the time of the site inspection.
Brownfields Inspection Report: Dunavant Street, 19038-15-060
08/18/2022 12:15 PM
Page 4 of 5
IV. Inspector Comments
V. PHOTOGRAPHS
Photo 1: View of vapor barrier, taped seams and columns taken from front of tenant space
bordering Dunavant St.
Performed Site Inspection following H&H barrier inspection earlier in the day as
described previously. No workers were onsite, so I was unable to enter the future retail
space at the time of the inspection. I contacted the H&H engineer following the DEQ
inspection, and the engineer indicated that the barrier installation had passed H&H’s
inspection.
Brownfields Inspection Report: Dunavant Street, 19038-15-060
08/18/2022 12:15 PM
Page 5 of 5
Photo 2: Photograph of barrier from opposite side of commercial space.
Photo 3: The Stego Wrap VIMS barrier was then adhered to the side of the adjacent
slab/overlapped barrier material using double-sided Stego Tack tape, with Stego Mastic also
used to seal the edge.