HomeMy WebLinkAbout18032_Carter Woodson_SIR_20220801 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 08/02/2022 8:11 AM I. Inspection Information Date & Time: 08/01/2022 10:36 AM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter, Seth Titley, Tyler Pearson Other Personnel: AECOM - John Moran, Jordan Harrell and Jim Dimitroff Location: Lat: 36.066566, Long: -80.23152148 Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 08/01/2022 10:36 AM Page 2 of 8 II. Project Information Number: 18032-14-034 Name: Carter G. Woodson Charter School Address: 420, 437 Goldfloss St City: Winston Salem County: Forsyth III. Environmental Current Use of Property: Institutional Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: Active VIMS operating during site visit. Since previous Site Inspection, labeling has been added to the exterior VIMS exhaust stacks, and the low vacuum alarms have been moved to the interior of the building as recommended (Photos 5 and 6). Potential air leakage from vicinity of suction point SSD-12 was investigated, and air within the building is being pulled beneath interior wall adjacent to the suction point, where a preferential pathway through the concrete slab must exist as verified using a smoke pen (Photos 7 and 8). Summary: N/A Summary: One story, primarily CMU block, middle school building. Summary: N/A (in vicinity of school building). Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 08/01/2022 10:36 AM Page 3 of 8 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A Classes are not currently in session, and with the active VIMS in operation, public exposure should be minimized, althouh IA, and sub-slab air sampling being performed during the site visit should confirm this. Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 08/01/2022 10:36 AM Page 4 of 8 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Connecting Summa cannister fitting/tubing within helium shroud prior to sampling. Sub-slab vapor-pin VMP-4 visible within cut-out in the bottom of shroud. The site inspection was performed to observe a sub-slab sampling event being performed by AECOM at the property. DEQ personnel arrived on-site in time to observe the first sub-slab sample collection being performed at VMP-4 (Photos 1 through 3). Initially, there was an issue with the helium leak test, with AECOM determining there was an air leak at the 3-way valve provided by the rental company. Additional plastic valves were purchased, and the interior of the helium shroud was replumbed. Following this modification, no additional issues were encountered during purge air helium leak tests, and sub-slab sampling was able to be performed as planned. DEQ personnel confirmed there was air leakage taking place below an interior wall adjacent to SSD- 12 while the sampling equipment was being set-up and helium tests were being performed at the second sub-slab sampling point VMP-2R (Photo 4). This leak testing was described previously in the Vapor Mitigation Systems Section. DEQ personnel left the property as AECOM finished collecting sub-slab sample VMP-2R following an update with the Brownfields PM. Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 08/01/2022 10:36 AM Page 5 of 8 Photo 2: fittings connected, shroud sealed, and helium being injected into shroud. Photo 3: Tedlar bag being filled to check for presence of helium. Prior to valve replacement, high concentrations of helium observed in purge air. Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 08/01/2022 10:36 AM Page 6 of 8 Photo 4: Sampling shroud, Summa cannister and additional equipment set up on VMP-2R. Photo 5: Labels installed below VIMS blowers, and exterior low vacuum alarms removed and relocated to interior of building since June 30, 2022 Site Inspection. Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 08/01/2022 10:36 AM Page 7 of 8 Photo 6: VIMS alarms relocated from building exterior to building interior. Green/Red alarm lamps clearly visible indoors, although audible portion of alarm is turned off according to AECOM during prior Site Inspection Photo 7: Smoke from smoke pen visible in photo when held away from black rubber floor base. Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 08/01/2022 10:36 AM Page 8 of 8 Photo 8: Smoke is no longer visible as it is being pulled below the interior wall. Note, there is no air leakage around the suction point itself.