HomeMy WebLinkAbout9102T_VanceTS_AssessResponseLetter_20200707ROY COOPER J"o
GovernorELIZABETH S. BISERSecretary -
MICHAEL SCOTT NORTH CAROLINA
Director Environmental Quality
June 30, 2022
Sent via email: randy.deming@gflenv.com
Mr. Randy Deming
General Manager
Waste Industries, LLC
3453 NC HWY 39 N
Henderson, NC 27536
SUBJECT: Transfer Station Assessment Report
Vance County Transfer Station
9102T-TRANSFER-1997
Vance County
Dear Mr. Randy Deming,
The State of North Carolina, Division of Waste Management Solid Waste Section (Section) has completed the
review of the Transfer Station Assessment Report (report) for Vance County Transfer Station. The Report was
submitted by Smith + Gardner on 6/24/2021 in accordance with 15A North Carolina Administrative Code
13B .0401(b) and guidance provided to facilities in the February 9, 2021, memo from Ed Mussler, Section Chief.
The intent of the report was to self -assess and demonstrate compliance with the rules in 15A NCAC 13B .0400,
readopted effective January 1, 2021, with a primary focus of vital infrastructure at the facility as part of
transitioning under the new rules and other life of site permit requirements.
In summary, the report made the following recommendations: Repair asphalt paved entrance at the transfer
station apron. Replace/update signage at entrance. Monitor "pump and haul" activities for leaks and spills.
Monitor tipping floor wear and cracks and joints. Repair damaged push wallssteel plates and concrete. Monitor
south wall builidng panels and columns. Monitor pit and cantilevered edge of tipping floor.
Based upon our review, the Section agrees with the report as submitted.
"At this time, please proceed with the implementation of the recommendations in the report. Per 15A NCAC
13B .0401(b)(3), the facility has until June 30, 2025 to fully implement the recommendations"
Also, per the report recommendations, please submit a revised operations plan as well as a closure plan with
closure cost estimates to include all information now required by 15A NCAC 13B .0404, .0405 and .0406.
Revised operations plan and closure plan maybe submitted to Donna Wilson at the address below. Please note,
the Section has established an electronic form for the submittal of Transfer Station closure cost estimates and
requests you submit the cost estimates in this manner using the following link:
https://edocs.deci.nc.gov/Forms/TransferStation FA . The requested response, plans, and cost estimates
should be submitted to the Section within 90 days of receipt of this letter.
01-11- E Q�� North Carolina Department of Environmental Quality I Division of Waste Management
217 West Jones Street 1 1646 Mail Service Center I Raleigh, North Carolina 27699-1646
NORTH CAROLINA -
oepamnemof rnvimnmemmouaifty /� 919.707.8200
If you have any questions, please reach out directly to Donna Wilson, permitting engineer at 919-707-8255 or
Don na.Wilson@ncdenr.�ov .
Sincerely,
t:t=ranch Manager
DWM - Solid Waste Section
Copies(email): Smith + Gardner,
Amanda Thompson - SWS-RO
Sarah Moutos - SWS-ARO
E Q North Carolina Department of Environmental Quality I Division of Waste Management
217 West Jones Street 1 1646 Mail Service Center I Raleigh, North Carolina 27699-1646
NORTH CAROLINA _
OepammammEmimnmameiausil /`� 919.707.8200