Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1302_Cabarrus_CDLF_April22GW_FID1691412_20220701
Cabarrus County C&D Landfill Semi -Annual Sampling Report Facility Permit # 1302-CDLF-2006 (April 2022 Sampling Event) Prepared July 2022 E USE ONLY: E]PaperRerporl Electronic Da la • Email CD data loaded: Yes! No OocJE%%" At C ❑ENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Renortina Form Notice: This form and any information attached to it are 'Public Records' as defined in NC General Statute 132-1. As such, these documents are available for Inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored uniL • Please type or print legibly, • Attach a notification table with values (hat attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must indude a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off-sAe source, pre-existing Condition, Etc.). Attach a notification (able of any groundwater or surface water values that equal or exceed the reporting limits. • Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This incudes any structures on or nearby the facility (NCAC 13B .1629 (4Xa)(i). • Send the original signed and seated form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner) Consultant - CDM Smith Inc. Contact for questions about data formatting. Include data pre pacer's name, telephone number and E-mail address: Name: Janetle Farley Phone: 4919) 325-3500 E-mail: faHeVibpcdmsmjth.com NC Landfill Rule: Adam sampling dates (e.g., Facility name: Facility Address: Facility Permit N (.0500 or .1600) October 20-24. 2006) r banas County C&D Landfill 4441 Irish Potato Road 1302-MSWL-F- .0500 April 25r28, 2022 Concord. North Carolina 28025 2006 Environmental Status: (Check all that apply) Initmi/Background Monitoring ® Detection Monitoring Assessment Monitoring of data submitted: (Check all that apply) Groundwater monitoring data from monitoring weJIs Methane gas monitoring data Groundwater monitoring data from private water supply wells ❑ Corrective action data (specify) Leachate monitoring data ❑ Surface water monitoring data ❑ttrer(specity) ❑ Corrective Acton Notification attached? ®No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water montoring points, dates, analytical values. NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preiiminary analysis of the cause and significance of any concentration. Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and exposive methane gas limits. Certification �To the best of my knowledge, the Information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification Including the possibility of a fine and imprisonment. Janelle Farley Consultant (919) 325-3500 rHrarrrrri Facility Representative Name (Print) Title (Area Codes Telephone r ist Seal 5400 Gierswood Avenue, Suite 400, Raleigh, North Carolina 2T612 Facility Representative Address 2623 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 612009 Smith 5400 Glenwood Avenue, Suite 400 Raleigh, North Carolina 27612 tel: 919 325-3500 fax: 919 781-5730 July 1, 2022 Ms. Jaclynne Drummond North Carolina Department of Environmental Quality Division of Waste Management Solid Waste Section 2090 U.S. 70 Highway Swannanoa, North Carolina 28778 Subject: April 2022 Semi -Annual Sampling Report Cabarrus County C&D Landfill Facility Permit No. 1302-CDLF-2006 Dear Ms. Drummond: CDM Smith Inc., on behalf of Cabarrus County, is submitting an electronic copy of the April 2022 semi- annual sampling event report for the Cabarrus County C&D Landfill. This letter report presents the results of the recently completed sampling at the C&D Landfill and constitutes the first semi-annual sampling event for 2022. The approved monitoring well network for the C&D Landfill consists of background wells CD -Is and -1d; compliance wells CD-2, -4 Rep, -7, and -9; and surface water sample location SW-3. CD-4 Rep was installed in January 2009 as part of the proposed Phase 1 C&D Landfill expansion. Monitoring well CD-7, formerly piezometer B-7, was added to the monitoring program in July 2014 as part of the Phase 2 C&D Landfill expansion. Monitoring well CD-9 was installed on March 19, 2017, as part of the Phase 3 C&D Landfill expansion. Field activities and sampling results for the groundwater and surface water samples are discussed below. Field Activities Groundwater samples from the Cabarrus County C&D Landfill were collected on April 25-27, 2022. Surface water sample location SW-3 was dry during the April 2022 sampling event. Groundwater samples were collected from the monitoring wells by use of disposable, laboratory decontaminated bailers. Monitoring well locations and the surface water location for the C&D Landfill are provided on Figure 1. Groundwater elevations were measured at each well on April 25, 2022, prior to sampling and are presented in Table 1. Well construction details for each monitoring well are also provided in Table 1. These groundwater elevations were used to construct potentiometric contours for this sampling event and are presented on Figure 1. After depth to groundwater was measured, each well was purged prior 0 WATER + ENVIRONMENT +TRANSPORTATION + ENERGY + FACILITIES Smith Ms. Jaclynne Drummond July 1, 2022 Page 2 to sampling to provide fresh formation water within the well water column. Each purge volume was measured for pH, conductivity, turbidity, temperature, dissolved oxygen, and oxidation-reduction potential using a YSI-556 multi -parameter water quality meter and a HANNA HI 98703 turbidity meter. The water quality parameters at the time of sampling are presented in Table 2. Sampling Results Pace Analytical Services, LLC, located in West Columbia, South Carolina, analyzed the groundwater samples for North Carolina Appendix I volatile organic compounds (VOCs) plus tetra hydrofuran, North Carolina Appendix I metals plus iron, mercury, and manganese, alkalinity, total dissolved solids (TDS), chloride, and sulfate except for CD-4 Rep. Samples collected from CD-4 Rep were analyzed for North Carolina Appendix I VOCs and metals. In a letter dated May 28, 2019, the Solid Waste Section requested that all groundwater and surface water samples collected from landfills be analyzed for 1,4-dioxane after July 1, 2018. On July 1, 2019, the Solid Waste Section approved the removal of 1,4-dioxane from the sampling program due to two consecutive non -detect events (January and May 2019), except for SW-3. The analytical results were reported to the laboratory specific method detection limit (MDL) and are quantifiable at or below the limit of quantitation (LOQ). All monitoring wells for the C&D Landfill had detections of analytes above the MDL but below the LOQ. These detections were qualified as estimated or "J" flags. The following list indicates the analytes detected above the LOQ at each sampling location. No "J" flag detections are provided. Underlined analytes exceeded the 15A NCAC 02L .0202 (NC 2L) Groundwater Standard or Interim Maximum Allowable Concentration Standard. CD-1s (Background) General Chemistry: Metals: Volatile Organic Compounds: CD-1d (Background) General Chemistry: Metals: Volatile Organic Compounds: Alkalinity, Chloride, Sulfate, TDS Barium, Iron, Manganese None Detected Not Analyzed Barium, Iron, Manganese, Vanadium None Detected CD-2 General Chemistry: Alkalinity, Chloride, Sulfate, TDS Metals: Barium, Iron, Manganese, Vanadium Volatile Organic Compounds: Benzene, Chloroethane, 1,1-Dichloroethane, cis-1,2-Dichloroethene to Smith Ms. Jaclynne Drummond July 1, 2022 Page 3 CD-4 Rep Metals: Volatile Organic Compounds: CD-7 Barium, Cobalt 1,1-Dichloroethane General Chemistry: Alkalinity, Chloride, Sulfate, TDS Metals: Barium, Cobalt, Copper, Iron, Manganese, Nickel Volatile Organic Compounds: Benzene, Chloroethane, 1,4-Dichlorobenzene, 1,1-Dichloroethane, 1,2-Dichloroethane, cis- 1,2-Dichloroethene, Methylene Chloride, Trichlorofluoromethane, Vinyl Chloride CD-9 General Chemistry: Metals: Volatile Organic Compounds: Alkalinity, Chloride, Sulfate, TDS Barium, Iron None Detected SW-3 General Chemistry: Dry Metals: Dry Volatile Organic Compounds: Dry "J" flags were not included in the previous list, but CD-2 had a "J" flag detection of cobalt that exceeded its standard. General chemistry analytes in samples collected from CD-1d were not analyzed due to a laboratory error. Equipment and trip blanks were analyzed for quality control. A duplicate sample was also analyzed for quality control. There were no detections in the equipment or trip blanks above the MDLs. The duplicate sample, identified as DUP, was collected from CD-2. The duplicate sample had similar concentrations as those detected in CD-2 except for estimated detections of chromium and copper below their respective standard in samples collected from CD-2 that were not detected in the duplicate sample. Metals detected above the standards are likely naturally occurring based on concentrations in the background monitoring wells or are from elevated turbidity at the time of sample collection. Benzene, and 1,1-dichloroethane were detected above their respective NC 2L Groundwater Standards in samples collected from CD-2 during the April 2022 sampling event. Benzene and 1,1-dichloroethane were previously detected above the standards in samples collected from CD-2 during the November 2021 sampling event. 1,1-Dichloroethane was also detected above its standard during the September 2020 sampling event. Benzene, 1,2-dichloroethane, and vinyl chloride were detected above the NC 2L Groundwater Standards in samples collected from CD-7 in both the November 2021 and April 2022 t. Smith Ms. Jaclynne Drummond July 1, 2022 Page 4 sampling events. In September 2020 and March 2021, only vinyl chloride was detected above the NC 2L Groundwater Standard. Future detections above the standards will be monitored to evaluate trends. A complete summary of all detected constituents from the April 2022 sampling event is presented in Table 3. The laboratory analytical report is provided in Appendix A. The next semi-annual sampling event will be completed in the fall of 2022. If you have any questions or require further explanation, do not hesitate to call me at (919) 325-3500 or by email at colonemf@cdmsmith.com. Very truly yours, Mathew F. Colone, P.G. CDM Smith Inc. cc: Kevin Grant, Cabarrus County 0 Table 1 Monitoring Well Construction Summary and Groundwater Elevations April 2022 Semi -Annual Sampling Event Cabarrus County C&D Landfill Facility Permit Number 1302-CDLF-2006 Depth (feet bgs) Facility Permit Monitoring Well Installation Geology of Total Depth ' Monitoring Latitude Longitude Diameter Depth to Number Code Date Screened Interval (feet BTOC) Screen F ter Fln Seal TOC Groundwater Groundwater Interval e Interval Elevation (feet BTOQ Elevation CD-1s 1302-CDLF-2006 8/7/2006 35.47788 80.52334 Saprolite 29.53 18.0-28.0 16.0-28.0 14.0-16.0 2.0 755.00 21.14 733.86 (background well) CD-1d 1302-CDLF-2006 7/21/2004 35.47788 80.52340 PWR 52.15 40.0-50.0 38.0-50.0 36.0-38.0 2.0 757.40 23.75 733.65 (background well) 1302-CDLF-2006 CD-2 9/12/2006 35.47698 80.52494 Saprolite 25.69 9.0-24.0 7.0-24.0 5.0-7.0 2.0 733.00 11.31 721.69 1302-CDLF-2006 CD-4 Rep 1/15/2009 35.47656 80.52210 Saprolite 19.41 6.0-16.0 4.0-16.0 2.0-4.0 2.0 739.15 8.04 731.11 1302-CDLF-2006 CD-7 11/25/2002 35.47567 80.52551 Bedrock 46.31 34.0-44.0 32.0-44.0 30.0-32.0 2.0 744.81 38.52 706.29 1302-CDLF-2006 CD-9 3/9/2017 35.47488 80.52564 PWR 51.00 36.0-51.0 34.0-51.0 32.0-36.0 2.0 748.13 41.93 706.20 Notes: 1. BTOC - Below Top of Casing 2. bgs - Below Ground Surface 3. PWR - Partially Weathered Rock 4. CD-4 Rep was installed as part of the proposed Phase 1 C&D Landfill expansion in November 2010. 5. CD-7 (formerly piezometer B-7) was added to the monitoring program in July 2014 as part of the Phase 2 C&D Landfill expansion. 6. CD-9 was installed as part of the Phase 3 C&D Landfill expansion in March 2017. CDM Smith Page 1 of 1 July 2022 Table 2 Water Quality Measurements April 2022 Semi -Annual Sampling Event Cabarrus County C&D Landfill Facility Permit Number 1302-CDLF-2006 Water Quality Measurements Monitoring Well Code pH ConductivityORP Turbidity Oxygen I I CD-15 5.95 130 16.7 4.60 204.4 9 (background well) CD -Id 6.14 119 16.9 0.72 196.2 24 (background well) CD-2 5.35 219 14.9 0.42 171.2 58 CD-4 Rep 5.76 160 14.5 0.31 75.9 28 CD-7 5.86 658 17.6 0.24 166.2 4 CD-9 6.00 231 16.9 1.04 159.3 17 Surface Water Sample Location SW-3 Dry Notes: 1. Water quality measurements were collected on April 25-27, 2022. 2. CD-4 Rep was installed as part of the proposed Phase 1 C&D Landfill expansion in November 2010. 3. CD-7 (formerly piezometer B-7) was added to the monitoring program in July 2014 as part of the Phase 2 C&D Landfill expansion. 4. CD-9 was installed as part of the Phase 3 C&D Landfill expansion in March 2017. 5. µS/cm - Microsiemens per centimeter 6. mg/L - Milligrams per liter 7. ORP - Oxidation -Reduction Potential 8. NTUs - Nephelometric Turbidity Units 9. mvs - Millivolts 10. S.U. - Standard Unit Smt� Page 1 of 1 July 2022 Table 3a Detected Groundwater Constituents - General Chemistry and Metals April 2022 Semi -Annual Sampling Event Cabarrus County C&D Landfill Facility Permit Number 1302-CDLF-2006 250,0001 , ,,, 1 46,000 3,900 SOO,000 1 1. 1 1.0 1 700 1 4 45.51 1 2 1 10 1 3.301 1.191 11,000 300 8.751 3,120 1 15 1.121 1 50 63.4 1 1 100 3.011 1 20 20 1 2 1 7 12.7J 1,000 12.6B CD-1s 7-May-12 158,000 CD-1s 28-Nov-12 39,000 4,100 110,000 63.8J 0.11.1 5.65J 3.05J 11.6 5,210 1.43J 139 4.66.1 17.11 16.9 CD-1s 7-May-13 42,000 4,000 120,000 0.941 2.41B 35.61 0.881 0.671 4.041 1,340 0.39J 37.7 1.781 0.13J 6.061 5.081 CD-1s 5-Nov-13 30,000 3,800 80,500 46.8J 0.12.1 3.59J 1.63.1 10.2 4,200 1.35.1 82.2 3.50J 8.41E 15.48 CD-1s 6-May-14 42,000 3,800 111,000 28.81 4.141B 1.481 347E 0.11J 10.18 1.031 0.31J 3.401 2.98JB CD-1s 4-Nov-14 41,000 3,900 102,000 28.7J 0.131 1.31J 118 0.06J 6.6.1 1.04J 0.11.1 2.57JB 1.58.1 CD-1s 5-May-15 38,000 3,800 <5,000 113,000 1.631 29.5113 1.331 371 0.15J 13.8 0.103JB 1.17J 2.401 2.75JB CD-1s 27-Oct-15 43,000 3,800 110,000 1.001 28.4J 0.80J 0.39J 0.75J 234 0.12J 35.9 1.21.1 4.19CN,J 0.15.1 4.10J 3.3613-01,J CD-1s 17-May-16 43,000 3,700 1,0001 130,000 23.91 0.941 0.991 446 0.12J 17.01 1.011 4.701 1.931 CD-1s 1-Nov-16 46,000 4,200 <5,000 71,000 30.5J 1.21 1.32.1 1.36J 647 0.281 70.8 1.35.1 4.30J 1302-CDLF-2006 CD-1s 9-May-17 49,000 3,600 1,3001 120,000 34.31 1.171 1.261 522 0.20J 24.4 0.971 6.691 1.821 CD-1s 31-Oct-17 50,000 4,200 1,0001 161,000 0.52J 36.1 1.81J 0.54J 2.87J 1,270 0.37J 31.2.1 1.41.1 6.91.1 4.00J CD-1s 11-Jun-18 49,000 3,890 904J (1) 28.91 214J 8.11 0.051J 4.3J 4.41 CD-1s 17-Dec-18 46,000 3,720 9911 119,000 26.7J 0.60J 3.6J 498 16.6 15.0.1 7.01 9.5.1 CD-1s 7-May-19 43,000 2,930 12,600 158,000 29.8 638 17.6 1.3J 7.01 5.1J CD -Is 5-Nov-19 43,000 3,750 2,160J 129,OOO111 31.9 1.01 1.8JB 153 0.070J 7.0.1 0.73.1 5.01 7.3JB CD-1s 18-May-20 49,100 4,570 4,280 141,OOO1-11 0.461 34.5 2.21 0.921 437 0.23J 11.3 1.41 6.4.1 6.91 CD -Is 23-Sep-20 51,000 5,500 2,500 140,000 34 1.31 1.51 630 21 4.9.1 4.2.1 CD-1s 17-Mar-21 53,000 9,400 4,800 140,000 42 1.31 290 7.6 4.1J 5.8J CD-1s 17-Nov-21 50,000 9,400 1,100 130,000 34 100 11 4.01 34 CD-1s 26-Apr-22 52,000 1 9,200 1 1,000 120,000 1 1 32 1 1 1 200 13 1 1 1 4.0J CD-1d 7-May-12 50,000 2,800 150,000 72.4J 0.581 3.91J 4.671 25 9,380 2.81J 170 5.58.1 26 27.98 CD-1d 28-Nov-12 46,000 3,000 128,000 0.33J 37.7J 0.071 2.381 0.941 12.6 1,900 1.14J 41.4 2.50J 8.90J 13 CD-1d 7-May-13 52,000 3,000 125,000 0.88J 1.02JB 31.2J 0.071 0.78J 4.SJ 1,080 0.49J 25.5 1.92.1 6.181 13.1 CD-1d 5-Nov-13 42,000 3,000 104,000 35.0J 0.861 4.341 1.131 812 1.90J 46.2 17.118 10.813 CD-1d 6-May-14 46,000 2,900 119,000 1.14J 37.8J 0.07J 0.051 3.22JB 1.161 7.34J 1,610E 0.81J 49.6E 2.74.1 0.12J 6.161 9.41.113 CD-1d 4-Nov-14 43,000 3,100 101,000 43.1J 0.161 0.111 2.251 9.091 3,400 0.871 88.5 2.88J 10.21E 10.7 CD-1d 5-May-15 44,000 2,900 <5000 115,000 34.516 0.84J 3.631 1,320 0.391 32.5 1.421 5.181 3.6816 CD-1d 27-Oct-15 46,000 2,900 120,000 0.421 42.3J 0.13J 1.871 2.15.1 8.181 3,170 0.971 87.4 2.49.1 4.37CN,J 0.06J 10.9J 14.0B-01 CD-1d 17-May-16 96,000 18,000 14,000J 202,000 81.1 0.461 4.86J 7.421 26.0 12,000 3.13J 287 7.111 2.11J 0.07J 29.3 29.7 CD-1d 1-Nov-16 52,000 3,400 <5,000 99,000 32.6J 1.191 0.771 2.821 1,200 0.33J 31.31 1.24.1 7.96J 4.29.1 1302-CDLF-2006 CD-1d 9-May-17 53,000 2,800 3,700J 167,000 33.9J 1.271 0.52J 1.81J 720 6.921 25.8J 1.091 6.951 3.121 CD-1d 31-Oct-17 52,000 3,300 3,300J 154,000 29.5J 0.68J 0.611 226J 0.111 11.81 0.64J 5.38J 1.24J CD-1d 12-Jun-18 51,000 3,200 3,330J 117,000 32.4J 2.5J 432 13.21 1.01 6.91 1 3.2 CD-1d 17-Dec-18 53,000 3,110 3,360J 121,000 31.9J 9.3J 2.31 591 0.41J 18.1 3.0J 6.8J 4.1.1 CD-1d 7-May-19 52,000 2,840 3,140J 134,000 30.7 1.4J 517 9.71 7.4J 2.91 CD-1d 5-Nov-19 48,000 3,140 3,070J 137,000111 0.481 30.1 1.91 1.1JB 197 0.13J 8.9J 1.81 4.71 8.2JB CD-1d 18-May-20 54,300 2,450 2,630 121,OOO1-13 29.1 0.641 27.2J 2.01 0.331 5.6J 2.01 CD-1d 22-Sep-20 53,000 3,100 2,000 130,000 0.67J 38 1.91 8.6 2,300 0.99J 47 4.2J 8.8 36 CD-1d 16-Mar-21 53,000 3,100 2,500 110,000 27 310 7.0 4.8J 3.11 CD-1d 17-Nov-21 51,000 3,300 2,600 110,000 1.41 33 2.4J 740 0.42J 32 1.51 6.0 5.8.1 CD-1d 27-Apr-22 1131 (13) (13) (13) 30 1.41 320 9.2 5.1 5.3.1 Smith Page 1 of 10 July 2022 Table 3a Detected Groundwater Constituents - General Chemistry and Metals April 2022 Semi -Annual Sampling Event Cabarrus County C&D Landfill Facility Permit Number 1302-CDLF-2006 250,0001 , ,,, 1 21,000 7,200 500,000 1 1. 1 1.0 1 700 1 4 1 2 1 10 36.41 0.191 2.711 1 3.381 11,000 300 1 5.031 2,760 15 1.941749.30.105-1 1 50 1 1 100 2.951 1 20 20 1 2 1 7 9.81 1,000 16.5B CD-2 7-May-12 104,000 CD-2 28-Nov-12 25,000 6,700 (1) 39.5J 0.13J 2.89J 2.951 4.401 2,720 1.42J2.721 10.11 7.921 CD-2 7-May-13 20,000 7,200 80,000 0.341 1.251B 39.41 0.231 1.321 2.81 4.441 2,450 1.34J2.591 0.081 9.02J 8.791 CD-2 5-Nov-13 28,000 6,600 55,000 45.1J 0.20J 0.64J 3.311 4.011 1,600 1.60J87J 2.381 14J 7.77J8 CD-2 7-May-14 16,000 8,200 135,000 37.51 0.101 1.981B 2.481 2.261 1,130B 0.78JB 2.001 5.001CD-2 5-Nov-14 25,000 7,500 330,000 0.07J 46.OJ 2.21JB 2.691 3.591 2,000E 1.10J) 2.471 7.23J 6.92J8CD-2 6-May-15 16,000 8,100 136,000 52.01B 0.181 2.1OJB 2.901 5.911 2240 1.37181B 3.741 6.971 8.02JB CD-2 27-Oct-15 7,750 7,300 5,9001 178,000 0.83J 60.OJ 0.42J 3.948-01,1 3.711 8.711 5,150 2.67J ..731 5.501 4.05CN,J 0.08J 16.3.1 13.3 CD-2 18-May-16 20,000 7,900 <5,000 147,000 49.81 0.221 2.321 3.411 3.561 2,350 1.201 71.7 0.1891 2.681 8.341 7.621 CD-2 1-Nov-16 20,000 8,100 <5,000 850,000H-02 64.5J 0.26.1 3.10J 4.151 5.481 4,010 2.55J 99.5 0.0561 3.111 15.3.1 13.9 CD-2 9-May-17 12,500 9,100 2,5001 125,000 54.51 0.281 2.401 3.491 3.711 2,550B-03 1.711 68.1 0.1151 2.801 0.051 8.631 7.261 1302-CDLF-2006 CD-2 1-Nov-17 15,000 7,900 2,900J 635,000 54.OJ 0.16.1 1.79J 3.101 2.781 1,630 1.02J 62.3 0.079J 2.581 7.10J 7.221 CD-2 (dup) 1-Nov-17 16,000 7,400 1,6001 885,000 57.61 0.171 2.051 3.001 4.011 1,840 1.081 64.1 0.0701 2.7761 8.041 8.191 CD-2 12-Jun-18 29,000 7,250 4,820J 88,000 58.5J 0.17.1 2.21 2.8J 2.61 1,280 0.63J 51.6 0.12J 3.1.1 6.61 8.7.1 CD-2(dup) 12-Jun-18 27,000 7,460 4,620J 91,000 56.3J 0.171 1.91 2.61 2.61 1,200 0.631 48.3 0.111 2.8J 9.01 8.81 CD-2 18-Jan-19 40,000 10,500 18,700 107,000 27.2J 0.081J 1.41 300 0.31J 30.6 0.15J 1.2.1 4.2.1 CD-2 7-May-19 40,000 8,400 10,500 161,000 0.42J 41.7 0.0811 0.981 1.91 1.31 782 0.441 49.7 2.2J 4.71 5.41 CD-2 6-Nov-19 64,000 6,220 7,370 151,000 1.21 68.6 0.11J 1.21 2.3J 2.31B 896 0.601E 75.0 3.0.1 8.11 9.0J13 CD-2 20-May-20 77,700 7,630 5,200 112,000 0.611 78.5 0.721 2.OJ 1.21 309 0.281 79.7 2.9J 4.51 8.51 CD-2 25-Sep-20 79,000 9,400 2,900 230,000 110 0.26J 4.61 2.9J 7.8 3,900 2.8 110 5.0 12 13 CD-2 16-Mar-21 110,000 9,700 35,000 250,000 56 0.171 3.11 1.71 4.11 2,8005 1.9 79 3.1J 8.6 9.71 CD-2 16-Nov-21 89,000 17,000 6,800 74 0.15J 2.11 3.8J 2.71 3,300 1.3 170 3.7.1 6.4 7.6.1 CD-2 27-Apr-22 87,000 19,000 4,100 150,000 90 2.01 3.81 2.51 2,700 0.961 160 4.OJ 6.1 7.31 CD-2 (dup) 27-Apr-22 85,000 18,000 4,300 130,000 86 3.7J 2,000 0.59J 150 3.7.1 3.91 6.2.1 CD-3 7-May-12 75,000 4,500 177,000 41.7J 0.841 1.271 3.841 1,170 0.54J 32.6 3.371 6.181 6.811,B CD-3 28-Nov-12 104,000 5,100 (1) 46.7J 1.41J 1.901 4.351 1,740 0.82J 68.9 1.86.1 9.52.1 6.93.1 CD-3 7-May-13 122,000 4,800 181,000 33.8J 1.201 2.351 880 0.421 56.3 1.411 5.861 2.89J CD-3 5-Nov-13 59,000 4,500 121,000 64J 0.211 0.74J 3.471 10.6 5,170 2.061 I&W 3.25.1 21.2.1 12.26 1302-CDLF-2006 CD-3 7-May-14 61,600 4,200 127,000 28.7J 1.66JB 0.721 83.2E 4.41 1.14J 2.421 CD-3 5-Nov-14 82,000 13,000 13,0001 425,000 162 0.141 1.85JB 3.001 6.221 3,770E 1.21J 1,030 (1) 8.65.1 12.91 9.9416 CD-3 6-May-15 89,000 13,000 22,000J 280,000 1.38J 159 0.111 1.26J 2.84J 1,230E 0.42J 1,090 0.102113 7.251 5.29J 5.931 CD-3 27-Oct-15 95,000 13,000 23,OOOJ 255,000 155 0.101 1.02B-01,J 1.82.1 3.911 2,010 0.681 936 7.72.1 2.60CN,J 6.031 6.1111 CD-3 18-May-16 100,000 14,000 26,0001 311,000 194 0.121 1.60J 1.351 607 0.24J 1,010 7.881 1.19.1 4.021 3.731 CD-3 1-Nov-16 95,000 14,000 27,0001 162,000 158 0.131 2.071 2.771 1,400 0.491 6.81.1 6.82.1 Smith Page 2 of 10 July 2022 Table 3a Detected Groundwater Constituents - General Chemistry and Metals April 2022 Semi -Annual Sampling Event Cabarrus County C&D Landfill Facility Permit Number 1302-CDLF-2006 250,0001 250,000 1 500,000 -- -- -- -- 1 3. 1 3.0 1 700 1 4 1 2 1 10 1 11,000 300 1.701 -- 1 3.5 0.171 1 50 -- 1 -- 1 100 11.31 1 20 20 2 1 7 3.031 1 1,000 16.1B CD-4 Rep 9-May-12 184 1.691 18.1 CD-4 Rep 29-Nov-12 -- -- -- -- 172 13.7 0.62J -- -- -- 7.03J 2.84J 2.1418 CD-4 Rep 10-May-13 -- -- -- -- 75.51 0.51 2.711 7.871 1.941 -- 0.881 -- -- 11.21 11.11 10.3 CD-4 Rep 7-Nov-13 -- -- -- -- 1.36J 6O.4J 0.35.1 0.O7J 0.77J 5.31.1 1.83.1 -- 0.57.1 -- -- 5.11.1 0. 13J 32 4.4018 CD-4 Rep 7-May-14 -- -- -- -- 62.41 0.311 0.051 3.251B 5.021 1.701 -- 0.321 -- -- 6.521 22.21 2.971B CD-4 Rep 5-Nov-14 -- -- -- -- 7O.0J 0.31.1 2.59.1 1.46.1 -- 0.72.1 -- -- 4.29.1 14.8JB 6.85.1 CD-4 Rep 6-May-15 -- -- -- - 58.41 0.391 1.131 5.941 1.901 -- -- -- 4.721 14.01 2.991 CD-4 Rep 27-Oct-15 -- -- -- -- 0.79J 57.9J 0.32.1 2.18J 5.86.1 8.95.1 -- 1.26.1 -- -- 1O.7J 4.14CN,J 13.9.1 8.34B-01,J CD-4 Rep 18-May-16 -- -- -- -- 1.091 56.21 0.461 1.241 7.311 1.021 -- 0.661 -- -- 5.431 18.01 3.701 CD-4 Rep 2-Nov-16 -- -- -- -- 46.1 0.27.1 1.35J 1.59.1 1.18J -- 0.9OJ -- -- 4.18.1 1.111 18.1.1 8.81.1 1302-CDLF-2006 CD-4 Rep 9-May-17 -- -- -- - 53.81 0.461 0.951 5.911 1.721 -- 0.521 -- -- 4.381 30.51 3.731 CD-4 Rep 31-Oct-17 -- -- -- -- 45.0J 0.181 0.97J 0.82J 0.58.1 -- 0.45.1 -- -- 2.75.1 1.881 7.68J 2.76.1 CD-4 Rep 6-Jun-18 -- -- -- -- 52.91 0.411 3.41 -- 0.741 -- -- 3.31 13.3.1 4.01 CD-4 Rep 19-Dec-18 -- -- -- - 1.1J 5O.9J 0.961 4.61 5.51 2.6.1 -- 2.9.1 -- -- 7.0J 1.41 15.5.1 11.6 CD-4 Rep 7-May-19 -- -- -- - 45.9 0.381 2.31 7.0 1.41 -- 1.1 -- -- 5.8 6.2J 13.7 CD-4 Rep 7-Nov-19 -- -- -- -- 1.41 31.5 O.40J 1.81 1.3J 1.4113 -- 0.83.1 -- -- 3.8.1 21.0 9.5JB CD-4 Rep 18-May-20 -- -- -- -- 1.31 70.9 0.481 0.981 6.6 0.771 -- 0.571 -- -- 5.1 11.6 12.5 CD-4 Rep 23-Sep-20 -- -- -- - 56 0.52 2.21 3.11 1.5.1 -- 1.4 -- -- 5.6 11 7.3.1 CD-4 Rep 18-Mar-21 -- -- -- - 1.91 43 0.83 5.8 6.7 2.31 -- 3.7 -- -- 7.4 26 10 CD-4 Rep 17-Nov-21 -- -- -- -- 66 O.28J 6.0 1.413J -- 0.61.1 -- -- 4.4.1 11 3.2.1 CD-4 Rep 27-Apr-22 -- -- -- -- 74 0.241 1.51 9.0 - 0.651 -- -- 3.91 4.3.1 CD-7 1-Jul-14 66,000 7,600 15,0001 420,000 53.1J 0.1311 669 8.741 4.111 4.06.1 CD-7 5-Nov-14 77,000 8,500 18,0001 1,170,000 1.32J 118 3.74 111,15.113 3.71.1 40.0 21,10013 13.6 341 (1) 8.911 0.241 75.8 19.413 CD-7 6-May-15 86,000 9,800 25,0001 660,000 1.71J 66.8J 0.28.1 0.45J 4.36J 1,630E 0.86J 43.4 3.36.1 4.141 3.33.1 CD-7 27-Oct-15 81,000 11,000 28,0001 291,000 87.2J 1.12 5.33B-01,J 1.52J 16.6 6,560 4.691 145 0.1381 6.61J 3.81CN,1 23.41 11.3 CD-7 18-May-16 90,000 10,000 29,OOOJ 282,000 74.8J 0.43.1 2.181 0.36.1 4.741 2,160 1.20J 59.4 0.1641 4.9OJ 1O.21 4.03.1 CD-7 1-Nov-16 100,000 13,000 34,000 413,000 82.6J 0.281 1.211 3.451 1,200 1.061 170 5.581 4.981 CD-7 9-May-17 120,000 14,000 35,000 667,000 86.8J 0.341 1.851 4.641 1,8806-01 1.701 123 5.5OJ 8.7OJ 4.13.1 CD-7 31-Oct-17 114,000 15,000 39,000 1,100,000 94.5J 0.271 1.301 0.44J 3.85J 1,300 1.13J 219 6.261 8.57J 4.181 CD-7 12-Jun-18 112,000 16,900 44,30OJ 350,000 1.01 97.9J 0.131 3.11 231J 215 7.6.1 6.31 6.3.1 1302-CDLF-2006 CD-7 18-Jan-19 126,000 17,600 50,400 280,000 152 0.241 2.01 12.5 7.81 178 3,930 17.51 5.11 CD-7 7-May-19 130,000 19,400 47,400 359,000 141 0.321 0.121 0.41J 5.0 6.3 64.9 2,570 13.7 1.91 7.2.1 CD-7 (dup) 7-May-19 129,000 19,100 48,000 391,000 147 0.361 0.881 5.4 9.9 847 0.31J 4,860 13.5 4.7.1 8.81 CD-7 7-Nov-19 148,000 21,800 47,800 332,000 152 0.291 0.91 5.2 6.98 1,240 0.601B 2,860 10.9 0.0731 3.91 10.96 CD-7 19-May-20 153,000 21,100 70,700 358,000 0.731 142 0.341 0.691 7.9 6.3 318 0.271 2,800 12.5 2.6.1 10.3 CD-7 22-Sep-20 170,000 23,000 56,000 370,000 180 0.391 0.251 1.51 8.4 25 1,100 1.3 3,100 14 0.251 5.4 7.91 CD-7 16-Mar-21 180,000 27,000 57,000 370,000 0.61J 180 0.511 0.211 1.61 13 55 1,300 1.1 3,900 0.191 15 5.1 8.81 CD-7 16-Nov-21 200,000 32,000 62,000 400,000 210 0.231 0.481 16 9.0 200 5,100 18 5.11 CD-7 (dup) 16-Nov-21 210,000 33,000 58,000 440,000 220 0.331 0.341 15 17 610 1.3 5,000 17 6.71 CD-7 25-Apr-22 250,000 35,000 67,000 460,00011 210 16 6.8 250 5,400 19 7.2J CD CJiiiI Page 3 of 10 July 2022 Table 3a Detected Groundwater Constituents - General Chemistry and Metals April 2022 Semi -Annual Sampling Event Cabarrus County C&D Landfill Facility Permit Number 1302-CDLF-2006 75,000 3,900 3,7001 0.2561 421 0.1911 8 26,600 6.551 1,360 13.81 0.2381 93.3 79.6 CD-8 1-Jul-14 120,000 CD-8 5-Nov-14 86,000 3,500 253,000 83.4J 1.64JB 5J 2,360E 0.59J 131 (1) 3.34J SAW 11.08 CD-8 6-May-15 57,000 3,300 <5000 138,000 0.361 53.8JB 131 1,030 0.271 58.5 0.O951B 2.431 4.031 9.731E CD-8 27-Oct-15 72,000 3,600 1,10OJ 132,000 0.75J 1.79J 162 O.32J 0.21J 5.88E-01,J.6 T0.48J4.13J 2,960 2.29J 95.2 9.53J 3.65CN,J 11.2J 1,430 1302-CDLF-2006 CD-8 (dup) 27-Oct-15 70,000 3,500 130,000 0.401 1.721 160 O.33J 0.211 5.54B-01,J.3 2,630 2.121 82.4 8.691 4.2OCN,1 10.61 1,310 CD-8 19-May-16 115,000 2,000 <5,000 205,000 0.49J 1.52J 133 O.20J 3.54J .1 2,320 1.28J 123 8.72J 13.2J 1,250 CD-8(dup) 19-May-16 110,000 2,000 <5,000 215,000 1.271 1.551 136 O.23J 0.10J 4.411 .2 3,230 1.871 129 9.761 14.81 1,600 CD-8 1-Nov-16 90,000 3,400 <5,000 517,OOOH-02 94.6J 0.17J 2.27J ..6 3,350 1.06.1 433 3.96J 18.1.1 244 CD-8(dup) 1-Nov-16 80,000 3,500 2,1001 428,0001-1-02 96.71 O.21J 3.111 2.471 18.8 4,640 1.18J 412 4.091 22.21 247 CD-9 9-May-17 115,000 5,200 3,60OJ 85,000 155 7.28.1 8.73J 44.7 8,700E-01 1.03.1 374 8.76J 0.11.1 34.2 25.3 CD-9 (dup) 9-May-17 110,000 5,700 3,6001 124,000 92.41 O.10J 2.141 4.671 14.1 2,62OB-01 0.491 236 5.561 11.91 7.561 CD-9 31-Oct-17 111,000 5,000 3,40OJ 380,000 0.59.1 307 O.56J M 20.9 126 23,300 2.88.1 680 13.8.1 2.39J 0.22.1 93.0 62.9 CD-9 12-Jun-18 115,000 5,130 3,8101 183,000 1.1J 131 0.161 6.21 4.01 30.4 5,380 0.981 139 5.01 26.8 15.2 CD-9 18-Jan-19 130,000 6,300 8,520 189,000 95.3.1 0.050.1 1.31 3.1J 374 158 6.8.1 3.9J 3.0.1 CD-9 (dup) 18-Jan-19 132,000 6,220 8,500 182,000 99.9.1 1.21 2.61 149 157 6.5J 3.61 2.2J CD-9 7-May-19 118,000 6,460 6,340 214,000 96.8 1.11 2.51 162 188 6.6 4.11 2.9.1 CD-9 7-Nov-19 123,000 5,930 4,5601 222,000 0.86.1 104 1.41 1.51 6.2B 963 0.16JB 166 6.0 9.0J 8.2JB 1302-CDLF-2006 CD-9(dup) 7-Nov-19 132,000 5,850 4,49OJ 191,000 0.95.1 67.2 0.761 3.51 4.SJB 667 0.20JB 179 4.2.1 9.5J 6.1JB CD-9 20-May-20 136,000 5,190 3,840 218,000 0.82.1 147 0.361 10.6 7.0 53.3 9,790 1.7 334 9.6 0.0881 40.9 23.7 CD-9(dup) 20-May-20 148,000 5,190 3,810 221,000 0.8OJ 155 O.34J 13.3 7.3 53.1 10,100 1.7 337 10.3 0.0901 41.3 23.4 CD-9 22-Sep-20 130,000 4,900 1,800 210,000 99 1.61 1.4J 8.9 1,300 160 5.5 7.3 5.0J CD-9 (dup) 22-Sep-20 130,000 4,900 1,800 200,000 170 O.28J 8.0 6.3 51 9,200 1.3 300 9.0 34 22 CD-9 16-Mar-21 130,000 5,300 2,500 190,000 100 3.11 2.0J 16 2,900 0.521 180 5.9 13 7.2J CD-9(dup) 16-Mar-21 130,000 5,300 2,500 200,000 120 O.16J 5.6 3.31 28 5,100 0.961 230 7.0 21 12 CD-9 16-Nov-21 120,000 5,500 1,900 200,000 86 3.31 460 110 4.2.1 4.21 6.91 CD-9 27-Apr-22 120,000 5,000 6,800 170,000 76 92 4.SJ 3.01 Notes: 1. All units are in micrograms per liter (parts per billion). 2. NE -Standard Not Established; dup - Duplicate Sample; (-) - Not Analyzed 3. CD-4 Rep was installed as part ofthe proposed Phase 1 C&D Landfill expansion in January 2009. Beginning November 2011 samples collected from CD-4 Rep are only analyzed for Appendix I metals. 4. CD-3 was relocated on July 1, 2014, as part of the Phase 2 C&D Landfill expansion. CD-7 and -8 (formerly piezometers B-7 and -19) were added to the monitoring program in July 2014 as part of the Phase 2 C&D Landfill expansion. CD-3 and -8 were abandoned on February 2, 2017, as part of the Phase 3 C&D Landfill Expansion. 5. CD-9 was installed on March 9, 2017, as part of the Phase 3 C&D Landfill Expansion. 6. J - Indicates the analytical result is an estimated concentration between the method detection limit and the adjusted reporting limit. 7. B, B-01-The analyte concentration detected in the method blank was greaterthan the method detection limit. 8. CN - Detected silver concentrations were determined to be the result of contamination from the preservative acid used. 9. H-02, H1- Analysis was completed outside of hold time. 10. S -The laboratory had a matrix spike/matrix spike detection failure. 11. Alkalinity, chloride, sulfate, and total dissolved solids were added to the sampling program in May 2010. 12. (1) - Not analyzed due to laboratory oversight. 13. CD-1d was not analyzed for alkalinity, chloride, sulfate, and total dissolved solids due to a laboratory error. Concentration exceeds the 15A NCAC 02L.O2O2 (North Carolina 2L). - Indicates the result is below the detection limit. CD CJiiiI Page 4 of 10 July 2022 Table 3b Detected Groundwater Constituents - Volatile Organic Compounds April 2022 Semi -Annual Sampling Event Cabarrus County C&D Landfill Facility Permit Number 1302-CDLF-2006 CDM Smith Page 5 of 10 July 2022 Table 3b Detected Groundwater Constituents - Volatile Organic Compounds April 2022 Semi -Annual Sampling Event Cabarrus County C&D Landfill Facility Permit Number 1302-CDLF-2006 Smith Page 6 of 10 July 2022 Table 3b Detected Groundwater Constituents - Volatile Organic Compounds April 2022 Semi -Annual Sampling Event Cabarrus County C&D Landfill Facility Permit Number 1302-CDLF-2006 Smith Page 7 of 10 July 2022 Table 3b Detected Groundwater Constituents - Volatile Organic Compounds April 2022 Semi -Annual Sampling Event Cabarrus County C&D Landfill Facility Permit Number 1302-CDLF-2006 Notes: 1. All units are in micrograms per liter (parts per billion). 2. * - Interim Maximum Allowable Concentration (IMAC) 3. dup - Duplicate Sample 4. CD-4 Rep was installed as part of the proposed Phase 1 C&D Landfill expansion in January 2009. 5. CD-3 was relocated on July 1, 2014, as part of the Phase 2 C&D Landfill expansion. CD-7 and -8 (formerly piezometers B-7 and -19) were added to the monitoring program in July 2014 as part of the Phase 2 C&D Landfill expansion. CD-3 and -8 were abandoned on February 2, 2017, as part of the Phase 3 C&D Landfill Expansion. 6. CD-9 was installed on March 9, 2017, as part of the Phase 3 C&D Landfill Expansion. 7. J - Indicates the analytical result is an estimated concentration between the method detection limit and the adjusted reporting limit. 8. B - The analyte concentration detected in the method blank was greater than the method detection limit. - Concentration exceeds the 15A NCAC 02L .0202 (North Carolina 2L) or IMAC. Indicates the result is below the detection limit. Smith Page 8 of 10 July 2022 Table 3c Detected Surface Water Constituents - Metals and General Chemistry April 2022 Semi -Annual Sampling Event Cabarrus County C&D Landfill Facility Permit Number 1302-CDLF-2006 Notes: 1. Metal concentrations are in micrograms per liter (parts per billion). 2. General chemistry concentrations are in milligrams per liter (parts per million). 3. (3) - A Standard for total chromium has not been established. The value provided is for chromium (III). 4. (4) - North Carolina 15A NCAC 02B (NC 2B) Fish Consumption Standard 5. (5) - North Carolina In -Stream Target Value Freshwater Aquatic Life Standard 6. (6) - NC 2B Freshwater Aquatic Life Standard 7. (7) - North Carolina In -Stream Target Value Fish Consumption Standard 8. NS - No Standard 9.1- Indicates the analytical result is an estimated concentration between the method detection limit and the adjusted reporting limit. 10. B, B-01- The analyte concentration detected in the method blank was greater than the method detection limit. 11. H-02 -Total dissolved solids analysis was analyzed outside of hold time for SW-3. 12. (--) - Not Analyzed Concentration exceeds the NC 2B or In -Stream Target Value Freshwater Aquatic Life or Fish Consumption Standard for Class C Waters -July 2021 -Indicates the result is below the detection limit. smith Page 9 of 10 July 2022 Table 3d Detected Surface Water Constituents - Volatile Organic Compounds April 2022 Semi -Annual Sampling Event Cabarrus County C&D Landfill Facility Permit Number 1302-CDLF-2006 Notes: 1. Volatile organic compound concentrations are in micrograms per liter (parts per billion). 2. (Z) - North Carolina 15A NCAC 02B (NC 213) Fish Consumption Standard 3. (3) - North Carolina In -Stream Target Value Freshwater Aquatic Life Standard 4. (4) - NC 2B Freshwater Aquatic Life Standard 5. NS - No Standard 6. J - Indicates the analytical result is an estimated concentration between the method detection limit and the adjusted reporting limit. - Concentration exceeds the NC 2B or In -Stream Target Value Freshwater Aquatic Life or Fish Consumption Standard for Class C Waters - July 2021 Indicates the result is below the detection limit. Smith Page 10 of 10 July 2022 x ►i + ; x fp � y w�e� MGW-15 f MGW.1CO t '1 15 MGW 14 73 86' ` SW3 /. co ` L�3365 ri 65. 2� CEtD CD-4 Rep 73111 Landfill ` CD 7 CD .Y MGW-13,.[ 1.,N 706,20 UnIt2 A : 7 MGW 1] ry MW-BA A Unit f� 710,69 OM�GW-02 MW-J MW-1 \` ]01.49 MGW-2 689.22J� MW-10 r h� ^t, 169298 �\ ;5 MW-] JO j MGW-11 MGW-16 MW-K \ 69512 4 701.16 MWA / MW-G MW-5 v,_p ]06.58 , 685.84 681.10 ➢N0� / 1 MW-B / Unit 3 , 6]909/ IIao ' Borrow Area MGW-3` - IMW-E Rep MW-11 ./ 6]85] MW-0 i 683905W-1 MGW-10 690696.01 MW E 6I3 deep) 63 , MW C MW` I l M 689.01 -fiJ0 A 68215 67 29.4 �MGWI MGW-9 660AMWna -- MW-1 _ _ _660 6y� 665.10 MGW-4♦ MW-H AMW4s SW.2 674.00 6]4.88 MGW9 MW-H deep 0 673,54 AMW 2s 66 672.30 MW 3 6]0 65].3] AMW-2d MW M 6]2.68 660 L 6 649.64 65].9966 MW-3 deep MGW-6 MW-L deep 65967 659,56 Scale in Feet nommonowni 0 500 1000 North Carolina MGW-5 LEGEND Groundwater Monitoring Well Surface Water Sample Location ♦ Landfill Gas Well Location fifio— (dashed where Inferred) Contour Interval =10 Feet Appendix A aceAnalytical Report of Analysis CDM Smith 5400 Glenwood Avenue Suite 400 Raleigh, NC 27612 Attention: Mathew Colone Project Name: Cabarrus County Unit 2 & Background Lot Number:XD27004 Date Completed:05/31/2022 06/08/2022 10:15 PM Approved and released by: Project Manager II: Cathy S. Dover =w�4 aecRFo���A4W- TNI / AM Amflvue Acm^rmm Fvu rj (' 4eOfFAi� ACC R E OI TEO TESTINGL aORlTOAY The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 1 of 331 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative CDM Smith Lot Number: XD27004 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Where sampling is conducted by the client, results relate to the accuracy of the information provided, and as the samples are received Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved The NELAC Institute (TNI) standards, the Pace Analytical Services, LLC ("Pace") Laboratory Quality Manual, standard operating procedures (SOPS), and Pace policies. Any exceptions to the TNI standards, the Laboratory Quality Manual, SOPS or policies are qualified on the results page or discussed below. Pace is a TNI accredited laboratory; however, the following analyses are currently not listed on our TNI scope of accreditation: Drinking Water: VOC (excluding BTEX, MTBE, Naphthalene, & 1,2-dichloroethane) EPA 524.2, E. coli and Total coliforms SM 9223 B-2004, Solid Chemical Material: TOC Walkley-Black, Biological Tissue: All, Non - Potable Water: SGT-HEM EPA 1664B, Silica EPA 200.7, Boron, Calcium, Silicon, Strontium EPA 200.8, Bicarbonate, Carbonate, and Hydroxide Alkalinity SM 2320 B-2011, SM 9221 C E-2006 & SM 9222D-2006, Strontium SW-846 6010D, VOC SM 6200 B-2011, Fecal Coliform Colilert-18. VOA 8260D The continuing calibration verification (CCV) associated with analytical batch 40083 recovered outside acceptance criteria, low biased, for 2-Butanone (-25%). An LOQ standard was analyzed, and the target analyte was detected. Since the associated samples were non -detect, no corrective action was taken. The samples associated with this CCV are: XD27004-001 (MW-L), XD27004-002 (MW-3), XD27004-003 (MW-E deep), XD27004-004 (MW-E REP), XD27004-005 (AMW-1s), XD27004-006 (AMW-1d), XD27004-007 (AMW-2s), XD27004-008 (AMW-2d), and XD27004-011 (CD-1s). Samples XD27004-002 (MW-3), XD27004-003 (MW-E deep), XD27004-004 (MW-E REP), XD27004-005 (AMW-1s), and XD27004-006 (AMW-1d). Due to the large number of spiked analytes, there is a high probability that one or more analytes will recover outside acceptance limits. The laboratory's SOP allows for 10% of analytes to recover marginally outside criteria. The following analytes recovered marginally outside LCS criteria: 2-Hexanone (138%). Associated samples: XD27004- 014 (Trip Blank), XD27004-015 (MW-H), XD27004-016 (MW-X), XD27004-019 (MW-M), XD27004-022 (MW-H deep), XD27004-027 (MW-1), XD27004-028 (MW-F), XD27004-029 (MW-B), XD27004-030 (MW-K), XD27004-031 (MW-D), XD27004-032 (MW-C), XD27004-033 (MW-J), XD27004-034 (MW-A), XD27004-035 (CD-4 Rep), XD27004- 036 (TRIP BLANK), XD27004-046 (CD-2), XD27004-048 (DUP), XD27004-052 (CD-7), and XD27004-053 (TRIP BLANK). Sample XD27004-064 (CD-9) had to be analyzed from only the unpreserved vial and was done 1 day outside holding time. The preserved vials was inadvertently run for 1,4-dioxane SIM due to test scheduling error. Dissolved Gases-RSK175 The method blank associated with batch 40722 had Methane detected at a concentration that was above the DL but below the LOQ. All samples associated with this method blank that have detections for Methane have been flagged with a "B". The method blank associated with batch 41098 had Methane detected at a concentration that was above the DL but below the LOQ. All samples associated with this method blank that have detections for Methane have been flagged with a "B". The method blank associated with batch 41253 had Methane detected at a concentration that was above the DL but below the LOQ. All samples associated with this method blank that have detections for Methane have been flagged Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 2 of 331 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 with a "B". Metals 6020B Sample XD27004-017 (MW-L) was slightly cloudy in appearance; therefore in order to protect the integrity of the instrument it was diluted 2 fold. The LOQ has been elevated to reflect the dilution. The method blank associated with batch 39927 had Arsenic detected at a concentration that was above the DL but below the LOQ. All samples associated with this method blank were non -detect for Arsenic. Mercury 7470A The MS/MSD for batch 40151 and parent sample XD27004-046 (D-2), recovered marginally outside the lower control limit. The associated LCS passed all acceptance criteria. Nitrate 9056A The following samples was analyzed 22 minutes to —4.5 hours outside of analytical holding time due to instrument being down for 2 days and coming back on-line on 4/28/2022: XD27004-001 (MW-L), XD27004-002 (MW-3), XD27004-003 (MW-E deep), XD27004-004 (MW-E REP), XD27004-005 (AMW-1s), XD27004-006 (AMW-1d), XD27004-007 (AMW-2s), XD27004-008 (AMW-2d), and XD27004-011 (CD-1s). Samples XD27004-002 (MW-3), XD27004-003 (MW-E deep), XD27004-004 (MW-E REP), XD27004-005 (AMW-1s), XD27004-006 (AMW-1d), XD27004-007 (AMW-2s), and XD27004-008 (AMW-2d) were diluted due to matrix interference for the reanalysis. The opening CCB contained nitrate greater than 1/2 LOQ. The samples contained positive results greater than 1 Ox the result in the CCB and have been reported. The method blank and LCS associated with the samples (XD27004- 007 (AMW-2s) & XD27004-011 (CD-1s)) passed criteria. Sample XD27004-034 (MW-A) required reanalysis with dilutions due to matrix of non -target compounds which was performed outside of the analytical holding time. Both runs have been reported. Sample XD27004-001 (MW-L) is the parent sample of the MS/MSD associated with analytical batch XQ40227 in which the MS/MSD did not recover due to analyst error in making the spike. Data is consistent with this rerun sample, therefore data will be reported. The method blank associated with batch 39879 had Nitrate detected at a concentration that was above the DL but below the LOQ. All samples associated with this method blank that have detections for Nitrate have been flagged with a "B". The method blank associated with batch 40227 had Nitrate detected at a concentration that was above the DL but below the LOQ. All samples associated with this method blank that have detections for Nitrate have been flagged with a "B". The method blank associated with batch 401036 had Nitrate detected at a concentration that was above the DL but below the LOQ. All samples associated with this method blank that have detections for Nitrate have been flagged with a "B". The MS/MSD for batch 40227 and parent sample XD27004-001 (MW-L), recovered outside he lower control limit. The associated LCS passed acceptance criteria. TDS Sample XD27004-065 (EQ Blank) did not yield at least 2.5 mg dried residue after the maximum sample volume was filtered for TDS analysis resulting in a non -detect result. Sample XD27004-052 (CD-7) was done outside of holding time due to a scheduling error. As soon as the issue was noticed the TDS analysis was scheduled. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 whw.pacelabs.com Page 3 of 331 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Sulfide The MS for batch 39710 and parent sample XD27004-002 (MW-3), recovered outside the lower control limit. The associated LCS and MSD passed acceptance criteria. COD The MS/MSD for batch 39723 and parent sample XD27004-001 (MW-L), recovered marginally outside the lower limit. The associated LCS passed acceptance criteria. There were two metals nitric acid containers received for CD-1 d and no unpreserved container was received to perform the Alkalinity, Chloride and sulfate and TDS. If you have any questions regarding this report, please contact the Pace Project Manager listed on the cover page. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 whw.pacelabs.com Page 4 of 331 PACE ANALYTICAL SERVICES, LLC Sample Summary CDM Smith Lot Number: XD27004 Project Name: Cabarrus County Unit 2 & Background Project Number: Sample Number Sample ID Matrix Date Sampled Date Received 001 MW-L Aqueous 04/26/2022 0840 04/27/2022 002 MW-3 Aqueous 04/26/20221005 04/27/2022 003 MW-E deep Aqueous 04/26/2022 1105 04/27/2022 004 MW-E REP Aqueous 04/26/2022 1140 04/27/2022 005 AMW-1s Aqueous 04/26/20221305 04/27/2022 006 AMW-1d Aqueous 04/26/20221225 04/27/2022 007 AMW-2s Aqueous 04/26/20221440 04/27/2022 008 AMW-2d Aqueous 04/26/20221400 04/27/2022 009 MW-L deep Aqueous 04/26/2022 0910 04/27/2022 010 MW- 3 deep Aqueous 04/26/2022 0935 04/27/2022 011 CD-1s Aqueous 04/26/20221550 04/27/2022 012 CD-1d Aqueous 04/26/20221620 04/27/2022 013 DUP Aqueous 04/26/2022 0800 04/27/2022 014 Trip Blank Aqueous 04/26/2022 04/27/2022 015 MW-H Aqueous 04/26/20221334 04/27/2022 016 MW-X Aqueous 04/26/20221150 04/27/2022 017 MW-L Aqueous 04/27/2022 0815 04/28/2022 018 MW-3 Aqueous 04/27/2022 0835 04/28/2022 019 MW-M Aqueous 04/27/2022 0900 04/28/2022 020 AMW-2d Aqueous 04/27/2022 0915 04/28/2022 021 AMW-2s Aqueous 04/27/2022 0930 04/28/2022 022 MW-H deep Aqueous 04/27/2022 0950 04/28/2022 023 AMW-1d Aqueous 04/27/20221010 04/28/2022 024 AMW-1s Aqueous 04/27/20221030 04/28/2022 025 MW-E deep Aqueous 04/27/2022 1100 04/28/2022 026 MW-E Rep Aqueous 04/27/2022 04/28/2022 027 MW-I Aqueous 04/27/20221200 04/28/2022 028 MW-F Aqueous 04/27/20221215 04/28/2022 029 MW-B Aqueous 04/27/20221230 04/28/2022 030 MW-K Aqueous 04/27/20221253 04/28/2022 031 MW-D Aqueous 04/27/20221305 04/28/2022 032 MW-C Aqueous 04/27/20221325 04/28/2022 033 MW-J Aqueous 04/27/20221345 04/28/2022 034 MW-A Aqueous 04/27/20221420 04/28/2022 035 CD-4 Rep Aqueous 04/27/2022 1515 04/28/2022 036 TRIP BLANK Aqueous 04/27/2022 04/28/2022 037 MW-L Aqueous 04/27/2022 0830 04/28/2022 038 MW-3 Aqueous 04/27/2022 0847 04/28/2022 039 AMW-2d Aqueous 04/27/2022 0925 04/28/2022 040 AMW-2s Aqueous 04/27/2022 0940 04/28/2022 041 AMW-1d Aqueous 04/27/20221025 04/28/2022 042 AMW-1s Aqueous 04/27/20221045 04/28/2022 043 MW-E deep Aqueous 04/27/2022 1115 04/28/2022 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 5 of 331 Sample Summary (Continued) Lot Number: XD27004 Sample Number Sample ID Matrix Date Sampled Date Received 044 MW-E Rep Aqueous 04/27/2022 1140 04/28/2022 045 MW-A Aqueous 04/27/20221440 04/28/2022 046 CD-2 Aqueous 04/27/20221530 04/28/2022 047 CD-9 Aqueous 04/27/20221500 04/28/2022 048 DUP Aqueous 04/27/2022 0800 04/28/2022 049 CD-1s Aqueous 04/27/20221600 04/28/2022 050 CD-1s Aqueous 04/27/20221610 04/28/2022 051 CD-1d Aqueous 04/27/20221605 04/28/2022 052 CD-7 Aqueous 04/25/20221020 04/28/2022 053 TRIP BLANK Aqueous 04/27/2022 04/28/2022 054 MW-1 Aqueous 04/28/2022 0830 04/29/2022 055 MW-G Aqueous 04/28/2022 0845 04/29/2022 056 MW-10 Aqueous 04/28/2022 0935 04/29/2022 057 MW-5 Aqueous 04/28/20221025 04/29/2022 058 MW-11 Aqueous 04/28/20221110 04/29/2022 059 MW-7 Aqueous 04/28/20221200 04/29/2022 060 MW-8a Aqueous 04/28/20221240 04/29/2022 061 DUP Aqueous 04/28/2022 0800 04/29/2022 062 EQ Blank (Unit 1) Aqueous 04/28/2022 1410 04/29/2022 063 EQ Blank (Unit 2) Aqueous 04/28/2022 1400 04/29/2022 064 CD-9 Aqueous 04/27/20221500 04/29/2022 065 EQ Blank Aqueous 04/28/2022 1350 04/29/2022 066 Trip Blank Aqueous 04/28/2022 04/29/2022 (66 samples) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 6 of 331 PACE ANALYTICAL SERVICES, LLC Detection Summary CDM Smith Lot Number: XD27004 Project Name: Cabarrus County Unit 2 & Background Project Number: Sample Sample ID Matrix Parameter Method Result Q Units Page 001 MW-L Aqueous Alkalinity @ pH 4.5 su SM 232013- 45 mg CaCO3/L 20 001 MW-L Aqueous Chloride 9056A 3000 ug/L 20 001 MW-L Aqueous CO2 (calculation) SM 4500-CO2 120000 ug/L 20 001 MW-L Aqueous Sulfate 9056A 610 J ug/L 20 001 MW-L Aqueous Nitrate - N 9056A 88 BHS ug/L 20 001 MW-L Aqueous 1,1-Dichloroethane 8260D 26 ug/L 21 001 MW-L Aqueous 1,1-Dichloroethene 8260D 2.4 ug/L 21 001 MW-L Aqueous cis- 1,2-Dichloroethene 8260D 8.3 ug/L 21 001 MW-L Aqueous Methylene chloride 8260D 1.0 ug/L 21 001 MW-L Aqueous Tetrachloroethene 8260D 16 ug/L 21 001 MW-L Aqueous Trichloroethene 8260D 7.5 ug/L 21 001 MW-L Aqueous Trichlorofluoromethane 8260D 1.6 ug/L 21 002 MW-3 Aqueous Alkalinity @ pH 4.5 su SM 232013- 100 mg CaCO3/L 24 002 MW-3 Aqueous Chloride 9056A 5500 ug/L 24 002 MW-3 Aqueous CO2 (calculation) SM 4500-CO2 180000 ug/L 24 002 MW-3 Aqueous Sulfate 9056A 2900 J ug/L 24 002 MW-3 Aqueous 1,1-Dichloroethane 8260D 21 ug/L 25 002 MW-3 Aqueous 1,1-Dichloroethene 8260D 1.4 ug/L 25 002 MW-3 Aqueous cis- 1,2-Dichloroethene 8260D 9.5 ug/L 25 002 MW-3 Aqueous Tetrachloroethene 8260D 9.7 ug/L 25 002 MW-3 Aqueous Trichloroethene 8260D 6.0 ug/L 25 002 MW-3 Aqueous Trichlorofluoromethane 8260D 0.55 ug/L 25 003 MW-E deep Aqueous Alkalinity @ pH 4.5 su SM 232013- 450 mg CaCO3/L 28 003 MW-E deep Aqueous BOD, 5 day SM 521013- 6600 ug/L 28 003 MW-E deep Aqueous Chloride 9056A 49000 ug/L 28 003 MW-E deep Aqueous CO2 (calculation) SM 4500-CO2 520000 ug/L 28 003 MW-E deep Aqueous TOC SM 5310C- 2800 ug/L 28 003 MW-E deep Aqueous Benzene 8260D 0.63 ug/L 29 003 MW-E deep Aqueous Chlorobenzene 8260D 1.4 ug/L 29 003 MW-E deep Aqueous Chloroethane 8260D 14 ug/L 29 003 MW-E deep Aqueous 1,4-Dichlorobenzene 8260D 8.7 ug/L 29 003 MW-E deep Aqueous 1,1-Dichloroethane 8260D 0.67 ug/L 29 003 MW-E deep Aqueous 1,2-Dichloroethane 8260D 1.1 ug/L 29 003 MW-E deep Aqueous 1,2-Dichloropropane 8260D 0.84 ug/L 29 003 MW-E deep Aqueous 1,4-Dioxane 8260D (SIM) 7.0 ug/L 31 003 MW-E deep Aqueous Ethane RSK - 175 6.3 J ug/L 32 003 MW-E deep Aqueous Methane RSK - 175 8800 B ug/L 33 004 MW-E REP Aqueous Alkalinity @ pH 4.5 su SM 232013- 560 mg CaCO3/L 34 004 MW-E REP Aqueous Chloride 9056A 64000 ug/L 34 004 MW-E REP Aqueous CO2 (calculation) SM 4500-CO2 720000 ug/L 34 004 MW-E REP Aqueous Sulfate 9056A 2900 J ug/L 34 004 MW-E REP Aqueous TOC SM 5310C- 3900 ug/L 34 004 MW-E REP Aqueous Benzene 8260D 0.56 ug/L 35 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 7 of 331 Detection Summary (Continued) Lot Number: XD27004 Sample Sample ID Matrix Parameter Method Result Q Units Page 004 MW-E REP Aqueous Chlorobenzene 8260D 3.5 ug/L 35 004 MW-E REP Aqueous Chloroethane 8260D 5.4 ug/L 35 004 MW-E REP Aqueous 1,4-Dichlorobenzene 8260D 15 ug/L 35 004 MW-E REP Aqueous 1,1-Dichloroethane 8260D 1.3 ug/L 35 004 MW-E REP Aqueous 1,2-Dichloroethane 8260D 0.97 ug/L 35 004 MW-E REP Aqueous cis- 1,2-Dichloroethene 8260D 12 ug/L 35 004 MW-E REP Aqueous trans- 1,2-Dichloroethene 8260D 0.47 J ug/L 35 004 MW-E REP Aqueous 1,2-Dichloropropane 8260D 0.82 ug/L 35 004 MW-E REP Aqueous Vinyl chloride 8260D 3.4 ug/L 36 004 MW-E REP Aqueous 1,4-Dioxane 8260D (SIM) 3.6 ug/L 37 004 MW-E REP Aqueous Methane RSK - 175 280 B ug/L 38 005 AMW-1s Aqueous Alkalinity @ pH 4.5 su SM 232013- 110 mg CaCO3/1- 39 005 AMW-1s Aqueous Chloride 9056A 3500 ug/L 39 005 AMW-1s Aqueous CO2 (calculation) SM 4500-CO2 340000 ug/L 39 005 AMW-1s Aqueous Nitrate - N 9056A 53 BHJ ug/L 39 005 AMW-1s Aqueous 1,1-Dichloroethane 8260D 0.55 ug/L 40 005 AMW-1s Aqueous cis- 1,2-Dichloroethene 8260D 1.5 ug/L 40 005 AMW-1s Aqueous Methane RSK - 175 1100 B ug/L 42 006 AMW-1d Aqueous Alkalinity @ pH 4.5 su SM 232013- 230 mg CaCO3/1- 43 006 AMW-1d Aqueous Chloride 9056A 7400 ug/L 43 006 AMW-1d Aqueous CO2 (calculation) SM 4500-CO2 340000 ug/L 43 006 AMW-1d Aqueous Benzene 8260D 0.96 ug/L 44 006 AMW-1d Aqueous Chloroethane 8260D 1.9 ug/L 44 006 AMW-1d Aqueous 1,4-Dichlorobenzene 8260D 0.86 ug/L 44 006 AMW-1d Aqueous 1,1-Dichloroethane 8260D 11 ug/L 44 006 AMW-1d Aqueous cis-1,2-Dichloroethene 8260D 8.0 ug/L 44 006 AMW-1d Aqueous Tetrachloroethene 8260D 0.44 J ug/L 44 006 AMW-1d Aqueous Trichloroethene 8260D 2.2 ug/L 44 006 AMW-1d Aqueous Vinyl chloride 8260D 3.8 ug/L 45 006 AMW-1d Aqueous Methane RSK - 175 2300 B ug/L 46 007 AMW-2s Aqueous Alkalinity @ pH 4.5 su SM 232013- 72 mg CaCO3/1- 47 007 AMW-2s Aqueous Chloride 9056A 3100 ug/L 47 007 AMW-2s Aqueous CO2 (calculation) SM 4500-CO2 230000 ug/L 47 007 AMW-2s Aqueous Nitrate - N 9056A 370 BH ug/L 47 007 AMW-2s Aqueous 1,1-Dichloroethane 8260D 2.2 ug/L 48 007 AMW-2s Aqueous cis- 1,2-Dichloroethene 8260D 2.2 ug/L 48 007 AMW-2s Aqueous Tetrachloroethene 8260D 0.91 ug/L 48 007 AMW-2s Aqueous Trichloroethene 8260D 0.70 ug/L 48 007 AMW-2s Aqueous Methane RSK - 175 3.8 BJ ug/L 50 008 AMW-2d Aqueous Alkalinity @ pH 4.5 su SM 232013- 140 mg CaCO3/L 51 008 AMW-2d Aqueous Chloride 9056A 3200 ug/L 51 008 AMW-2d Aqueous CO2 (calculation) SM 4500-CO2 360000 ug/L 51 008 AMW-2d Aqueous Nitrate - N 9056A 58 BHJ ug/L 51 008 AMW-2d Aqueous Benzene 8260D 1.0 ug/L 52 008 AMW-2d Aqueous 1,4-Dichlorobenzene 8260D 1.2 ug/L 52 008 AMW-2d Aqueous 1,1-Dichloroethane 8260D 15 ug/L 52 008 AMW-2d Aqueous 1,1-Dichloroethene 8260D 1.0 ug/L 52 008 AMW-2d Aqueous cis- 1,2-Dichloroethene 8260D 15 ug/L 52 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 8 of 331 Detection Summary (Continued) Lot Number: XD27004 Sample Sample ID Matrix Parameter Method Result Q Units Page 008 AMW-2d Aqueous Methylene chloride 8260D 1.0 ug/L 52 008 AMW-2d Aqueous Tetrachloroethene 8260D 2.7 ug/L 52 008 AMW-2d Aqueous Trichloroethene 8260D 6.9 ug/L 52 008 AMW-2d Aqueous Methane RSK - 175 2.8 BJ ug/L 54 008 AMW-2d Aqueous Barium 6020B 65 ug/L 55 008 AMW-2d Aqueous Beryllium 6020B 0.21 J ug/L 55 008 AMW-2d Aqueous Nickel 6020B 1.9 J ug/L 55 009 MW-L deep Aqueous Tetrachloroethene 8260D 0.69 ug/L 56 009 MW-L deep Aqueous Barium 6020B 24 ug/L 58 009 MW-L deep Aqueous Zinc 6020B 5.4 J ug/L 58 010 MW- 3 deep Aqueous 1,1-Dichloroethane 8260D 0.85 ug/L 59 010 MW- 3 deep Aqueous Barium 6020B 50 ug/L 61 010 MW- 3 deep Aqueous Zinc 6020B 3.5 J ug/L 61 011 CD-1s Aqueous Alkalinity @ pH 4.5 su SM 232013- 52 mg CaCO3/1- 62 011 CD-1s Aqueous Chloride 9056A 9200 ug/L 62 011 CD-1s Aqueous CO2 (calculation) SM 4500-CO2 100000 ug/L 62 011 CD-1s Aqueous Sulfate 9056A 1000 ug/L 62 011 CD-1s Aqueous Nitrate - N 9056A 290 BH ug/L 62 011 CD-1s Aqueous TDS SM 2540C- 120000 ug/L 62 011 CD-1s Aqueous Barium 6020B 32 ug/L 67 011 CD-1s Aqueous Iron 6020B 200 ug/L 67 011 CD-1s Aqueous Manganese 6020B 13 ug/L 67 011 CD-1s Aqueous Vanadium 6020B 4.0 J ug/L 67 013 DUP Aqueous 1,1-Dichloroethane 8260D 18 ug/L 70 013 DUP Aqueous 1,1-Dichloroethene 8260D 1.6 ug/L 70 013 DUP Aqueous cis- 1,2-Dichloroethene 8260D 7.9 ug/L 70 013 DUP Aqueous Methylene chloride 8260D 0.64 ug/L 70 013 DUP Aqueous Tetrachloroethene 8260D 10 ug/L 70 013 DUP Aqueous Trichloroethene 8260D 5.1 ug/L 70 013 DUP Aqueous Trichlorofluoromethane 8260D 1.1 ug/L 70 013 DUP Aqueous Barium 6020B 24 ug/L 72 013 DUP Aqueous Zinc 6020B 4.7 J ug/L 72 015 MW-H Aqueous Barium 6020B 39 ug/L 78 015 MW-H Aqueous Chromium 6020B 1.4 J ug/L 78 015 MW-H Aqueous Copper 6020B 1.3 J ug/L 78 015 MW-H Aqueous Lead 6020B 0.40 J ug/L 78 015 MW-H Aqueous Nickel 6020B 1.9 J ug/L 78 015 MW-H Aqueous Vanadium 6020B 3.3 J ug/L 78 015 MW-H Aqueous Zinc 6020B 3.7 J ug/L 78 016 MW-X Aqueous Barium 6020B 25 ug/L 82 016 MW-X Aqueous Nickel 6020B 1.7 J ug/L 82 017 MW-L Aqueous Barium 6020B 110 ug/L 83 017 MW-L Aqueous Beryllium 6020B 0.70 J ug/L 83 017 MW-L Aqueous Chromium 6020B 5.9 J ug/L 83 017 MW-L Aqueous Cobalt 6020B 6.2 J ug/L 83 017 MW-L Aqueous Copper 6020B 3.5 J ug/L 83 017 MW-L Aqueous Lead 6020B 2.8 ug/L 83 017 MW-L Aqueous Nickel 6020B 11 ug/L 83 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 9 of 331 Detection Summary (Continued) Lot Number: XD27004 Sample Sample ID Matrix Parameter Method Result Q Units Page 017 MW-L Aqueous Vanadium 6020B 28 ug/L 83 017 MW-L Aqueous Zinc 6020B 29 ug/L 83 018 MW-3 Aqueous Barium 6020B 32 ug/L 84 019 MW-M Aqueous 1,1-Dichloroethane 8260D 1.4 ug/L 85 019 MW-M Aqueous cis- 1,2-Dichloroethene 8260D 0.44 J ug/L 85 019 MW-M Aqueous 1,4-Dioxane 8260D (SIM) 1.5 J ug/L 87 019 MW-M Aqueous Barium 6020B 33 ug/L 88 019 MW-M Aqueous Copper 6020B 1.3 J ug/L 88 019 MW-M Aqueous Lead 6020B 0.47 J ug/L 88 019 MW-M Aqueous Vanadium 6020B 3.7 J ug/L 88 020 AMW-2d Aqueous bis(2-Ethylhexyl)phthalate 8270D 3.2 J ug/L 89 021 AMW-2s Aqueous Barium 6020B 43 ug/L 90 021 AMW-2s Aqueous Beryllium 6020B 0.75 ug/L 90 021 AMW-2s Aqueous Lead 6020B 0.88 J ug/L 90 021 AMW-2s Aqueous Nickel 6020B 2.0 J ug/L 90 021 AMW-2s Aqueous Vanadium 6020B 4.3 J ug/L 90 021 AMW-2s Aqueous Zinc 6020B 13 ug/L 90 022 MW-H deep Aqueous Antimony 6020B 0.91 J ug/L 93 022 MW-H deep Aqueous Barium 6020B 40 ug/L 93 022 MW-H deep Aqueous Lead 6020B 0.26 J ug/L 93 022 MW-H deep Aqueous Zinc 6020B 7.7 J ug/L 93 023 AMW-1d Aqueous Antimony 6020B 2.3 ug/L 94 023 AMW-1d Aqueous Barium 6020B 130 ug/L 94 023 AMW-1d Aqueous Beryllium 6020B 0.17 J ug/L 94 023 AMW-1d Aqueous Chromium 6020B 3.4 J ug/L 94 023 AMW-1d Aqueous Cobalt 6020B 6.9 ug/L 94 023 AMW-1d Aqueous Copper 6020B 4.0 J ug/L 94 023 AMW-1d Aqueous Lead 6020B 1.4 ug/L 94 023 AMW-1d Aqueous Nickel 6020B 13 ug/L 94 023 AMW-1d Aqueous Zinc 6020B 13 ug/L 94 024 AMW-1s Aqueous Barium 6020B 75 ug/L 95 024 AMW-1s Aqueous Beryllium 6020B 1.1 ug/L 95 024 AMW-1s Aqueous Chromium 6020B 3.4 J ug/L 95 024 AMW-1s Aqueous Copper 6020B 7.8 ug/L 95 024 AMW-1s Aqueous Lead 6020B 1.9 ug/L 95 024 AMW-1s Aqueous Nickel 6020B 4.4 J ug/L 95 024 AMW-1s Aqueous Vanadium 6020B 7.9 ug/L 95 024 AMW-1s Aqueous Zinc 6020B 18 ug/L 95 025 MW-E deep Aqueous bis(2-Ethylhexyl)phthalate 8270D 2.8 J ug/L 96 025 MW-E deep Aqueous Arsenic 6020B 2.7 ug/L 97 025 MW-E deep Aqueous Barium 6020B 2200 ug/L 97 025 MW-E deep Aqueous Beryllium 6020B 0.35 J ug/L 97 025 MW-E deep Aqueous Cadmium 6020B 0.49 J ug/L 97 025 MW-E deep Aqueous Chromium 6020B 2.8 J ug/L 97 025 MW-E deep Aqueous Cobalt 6020B 30 ug/L 97 025 MW-E deep Aqueous Copper 6020B 8.3 ug/L 97 025 MW-E deep Aqueous Lead 6020B 48 ug/L 97 025 MW-E deep Aqueous Nickel 6020B 16 ug/L 97 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 10 of 331 Detection Summary (Continued) Lot Number: XD27004 Sample Sample ID Matrix Parameter Method Result Q Units Page 025 MW-E deep Aqueous Vanadium 6020B 3.6 J ug/L 97 025 MW-E deep Aqueous Zinc 6020B 25 ug/L 97 026 MW-E Rep Aqueous Barium 6020B 410 ug/L 98 026 MW-E Rep Aqueous Beryllium 6020B 0.43 ug/L 98 026 MW-E Rep Aqueous Chromium 6020B 2.0 J ug/L 98 026 MW-E Rep Aqueous Cobalt 6020B 9.9 ug/L 98 026 MW-E Rep Aqueous Copper 6020B 2.4 J ug/L 98 026 MW-E Rep Aqueous Lead 6020B 6.8 ug/L 98 026 MW-E Rep Aqueous Nickel 6020B 16 ug/L 98 026 MW-E Rep Aqueous Vanadium 6020B 6.5 ug/L 98 026 MW-E Rep Aqueous Zinc 6020B 19 ug/L 98 027 MW-I Aqueous 1,1-Dichloroethane 8260D 0.66 ug/L 99 027 MW-I Aqueous Tetrachloroethene 8260D 0.55 ug/L 99 027 MW-I Aqueous bis(2-Ethylhexyl)phthalate 8270D 2.6 J ug/L 101 027 MW-I Aqueous Antimony 6020B 0.59 J ug/L 102 027 MW-I Aqueous Barium 6020B 12 ug/L 102 027 MW-I Aqueous Chromium 6020B 2.1 J ug/L 102 027 MW-I Aqueous Vanadium 6020B 2.8 J ug/L 102 027 MW-I Aqueous Zinc 6020B 2.9 J ug/L 102 028 MW-F Aqueous 1,4-Dioxane 8260D (SIM) 14 ug/L 105 028 MW-F Aqueous Arsenic 6020B 1.5 J ug/L 106 028 MW-F Aqueous Barium 6020B 220 ug/L 106 028 MW-F Aqueous Cobalt 6020B 5.5 ug/L 106 028 MW-F Aqueous Nickel 6020B 9.9 ug/L 106 029 MW-B Aqueous 1,4-Dioxane 8260D (SIM) 13 ug/L 109 029 MW-B Aqueous Barium 6020B 120 ug/L 110 029 MW-B Aqueous Cobalt 6020B 11 ug/L 110 029 MW-B Aqueous Nickel 6020B 3.9 J ug/L 110 030 MW-K Aqueous cis- 1,2-Dichloroethene 8260D 1.9 ug/L 111 030 MW-K Aqueous Barium 6020B 22 ug/L 113 030 MW-K Aqueous Nickel 6020B 2.0 J ug/L 113 030 MW-K Aqueous Vanadium 6020B 2.8 J ug/L 113 031 MW-D Aqueous Benzene 8260D 3.9 ug/L 114 031 MW-D Aqueous Chlorobenzene 8260D 0.71 ug/L 114 031 MW-D Aqueous Chloroethane 8260D 0.57 ug/L 114 031 MW-D Aqueous 1,4-Dichlorobenzene 8260D 4.4 ug/L 114 031 MW-D Aqueous cis- 1,2-Dichloroethene 8260D 6.6 ug/L 114 031 MW-D Aqueous Trichloroethene 8260D 0.68 ug/L 114 031 MW-D Aqueous Vinyl chloride 8260D 1.7 ug/L 115 031 MW-D Aqueous Arsenic 6020B 1.5 J ug/L 116 031 MW-D Aqueous Barium 6020B 270 ug/L 116 031 MW-D Aqueous Cobalt 6020B 16 ug/L 116 031 MW-D Aqueous Nickel 6020B 30 ug/L 116 032 MW-C Aqueous bis(2-Ethylhexyl)phthalate 8270D 3.1 J ug/L 119 032 MW-C Aqueous Barium 6020B 15 ug/L 120 033 MW-J Aqueous Barium 6020B 15 ug/L 123 034 MW-A Aqueous Alkalinity @ pH 4.5 su SM 232013- 160 mg CaCO3/L 124 034 MW-A Aqueous Chloride 9056A 20000 ug/L 124 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 11 of 331 Detection Summary (Continued) Lot Number: XD27004 Sample Sample ID Matrix Parameter Method Result Q Units Page 034 MW-A Aqueous CO2 (calculation) SM 4500-CO2 670000 ug/L 124 034 MW-A Aqueous Sulfate 9056A 11000 ug/L 124 034 MW-A Aqueous TOC SM 5310C- 1900 ug/L 124 034 MW-A Aqueous Benzene 8260D 7.0 ug/L 125 034 MW-A Aqueous Chlorobenzene 8260D 0.92 ug/L 125 034 MW-A Aqueous Chloroethane 8260D 3.5 ug/L 125 034 MW-A Aqueous 1,4-Dichlorobenzene 8260D 20 ug/L 125 034 MW-A Aqueous 1,1-Dichloroethane 8260D 9.3 ug/L 125 034 MW-A Aqueous 1,2-Dichloroethane 8260D 0.42 J ug/L 125 034 MW-A Aqueous cis- 1,2-Dichloroethene 8260D 79 ug/L 125 034 MW-A Aqueous trans- 1,2-Dichloroethene 8260D 0.45 J ug/L 125 034 MW-A Aqueous 1,2-Dichloropropane 8260D 1.6 ug/L 125 034 MW-A Aqueous Tetrachloroethene 8260D 2.3 ug/L 125 034 MW-A Aqueous Trichloroethene 8260D 3.7 ug/L 125 034 MW-A Aqueous Vinyl chloride 8260D 2.6 ug/L 126 034 MW-A Aqueous Xylenes (total) 8260D 0.49 J ug/L 126 034 MW-A Aqueous Methane RSK - 175 10000 B ug/L 128 034 MW-A Aqueous Barium 6020B 47 ug/L 129 034 MW-A Aqueous Cobalt 6020B 8.2 ug/L 129 034 MW-A Aqueous Nickel 6020B 16 ug/L 129 034 MW-A Aqueous Zinc 6020B 3.3 J ug/L 129 035 CD-4 Rep Aqueous 1,1-Dichloroethane 8260D 1.4 ug/L 130 035 CD-4 Rep Aqueous Barium 6020B 74 ug/L 132 035 CD-4 Rep Aqueous Beryllium 6020B 0.24 J ug/L 132 035 CD-4 Rep Aqueous Chromium 6020B 1.5 J ug/L 132 035 CD-4 Rep Aqueous Cobalt 6020B 9.0 ug/L 132 035 CD-4 Rep Aqueous Lead 6020B 0.65 J ug/L 132 035 CD-4 Rep Aqueous Nickel 6020B 5.1 ug/L 132 035 CD-4 Rep Aqueous Vanadium 6020B 3.9 J ug/L 132 035 CD-4 Rep Aqueous Zinc 6020B 4.3 J ug/L 132 046 CD-2 Aqueous Alkalinity @ pH 4.5 su SM 232013- 87 mg CaCO3/1- 136 046 CD-2 Aqueous Chloride 9056A 19000 ug/L 136 046 CD-2 Aqueous Sulfate 9056A 4100 ug/L 136 046 CD-2 Aqueous TDS SM 2540C- 150000 ug/L 136 046 CD-2 Aqueous Benzene 8260D 1.3 ug/L 137 046 CD-2 Aqueous Chloroethane 8260D 0.77 ug/L 137 046 CD-2 Aqueous 1,1-Dichloroethane 8260D 8.8 ug/L 137 046 CD-2 Aqueous cis- 1,2-Dichloroethene 8260D 1.6 ug/L 137 046 CD-2 Aqueous Barium 6020B 90 ug/L 140 046 CD-2 Aqueous Chromium 6020B 2.0 J ug/L 140 046 CD-2 Aqueous Cobalt 6020B 3.8 J ug/L 140 046 CD-2 Aqueous Copper 6020B 2.5 J ug/L 140 046 CD-2 Aqueous Iron 6020B 2700 ug/L 140 046 CD-2 Aqueous Lead 6020B 0.96 J ug/L 140 046 CD-2 Aqueous Manganese 6020B 160 ug/L 140 046 CD-2 Aqueous Nickel 6020B 4.0 J ug/L 140 046 CD-2 Aqueous Vanadium 6020B 6.1 ug/L 140 046 CD-2 Aqueous Zinc 6020B 7.3 J ug/L 140 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 12 of 331 Detection Summary (Continued) Lot Number: XD27004 Sample Sample ID Matrix Parameter Method Result Q Units Page 048 DUP Aqueous Alkalinity @ pH 4.5 su SM 232013- 85 mg CaCO3/1- 141 048 DUP Aqueous Chloride 9056A 18000 ug/L 141 048 DUP Aqueous Sulfate 9056A 4300 ug/L 141 048 DUP Aqueous TDS SM 2540C- 130000 ug/L 141 048 DUP Aqueous Benzene 8260D 1.2 ug/L 142 048 DUP Aqueous Chloroethane 8260D 0.66 ug/L 142 048 DUP Aqueous 1,1-Dichloroethane 8260D 8.6 ug/L 142 048 DUP Aqueous cis- 1,2-Dichloroethene 8260D 1.5 ug/L 142 048 DUP Aqueous Barium 6020B 86 ug/L 145 048 DUP Aqueous Cobalt 6020B 3.7 J ug/L 145 048 DUP Aqueous Iron 6020B 2000 ug/L 145 048 DUP Aqueous Lead 6020B 0.59 J ug/L 145 048 DUP Aqueous Manganese 6020B 150 ug/L 145 048 DUP Aqueous Nickel 6020B 3.7 J ug/L 145 048 DUP Aqueous Vanadium 6020B 3.9 J ug/L 145 048 DUP Aqueous Zinc 6020B 6.2 J ug/L 145 051 CD-1d Aqueous Barium 6020B 30 ug/L 147 051 CD-1d Aqueous Copper 6020B 1.4 J ug/L 147 051 CD-1d Aqueous Iron 6020B 320 ug/L 147 051 CD-1d Aqueous Manganese 6020B 9.2 ug/L 147 051 CD-1d Aqueous Vanadium 6020B 5.1 ug/L 147 051 CD-1d Aqueous Zinc 6020B 5.3 J ug/L 147 052 CD-7 Aqueous Alkalinity @ pH 4.5 su SM 232013- 250 mg CaCO3/1- 148 052 CD-7 Aqueous Chloride 9056A 35000 ug/L 148 052 CD-7 Aqueous Sulfate 9056A 67000 ug/L 148 052 CD-7 Aqueous TDS SM 2540C- 460000 H ug/L 148 052 CD-7 Aqueous Benzene 8260D 1.5 ug/L 149 052 CD-7 Aqueous Chloroethane 8260D 0.94 ug/L 149 052 CD-7 Aqueous 1,4-Dichlorobenzene 8260D 1.3 ug/L 149 052 CD-7 Aqueous 1,1-Dichloroethane 8260D 3.2 ug/L 149 052 CD-7 Aqueous 1,2-Dichloroethane 8260D 0.58 ug/L 149 052 CD-7 Aqueous cis- 1,2-Dichloroethene 8260D 5.0 ug/L 149 052 CD-7 Aqueous Methylene chloride 8260D 0.67 ug/L 149 052 CD-7 Aqueous Tetrahydrofuran 8260D 3.7 J ug/L 149 052 CD-7 Aqueous Trichloroethene 8260D 0.42 J ug/L 149 052 CD-7 Aqueous Trichlorofluoromethane 8260D 0.51 ug/L 150 052 CD-7 Aqueous Vinyl chloride 8260D 3.7 ug/L 150 052 CD-7 Aqueous Barium 6020B 210 ug/L 152 052 CD-7 Aqueous Cobalt 6020B 16 ug/L 152 052 CD-7 Aqueous Copper 6020B 6.8 ug/L 152 052 CD-7 Aqueous Iron 6020B 250 ug/L 152 052 CD-7 Aqueous Manganese 6020B 5400 ug/L 152 052 CD-7 Aqueous Nickel 6020B 19 ug/L 152 052 CD-7 Aqueous Zinc 6020B 7.2 J ug/L 152 054 MW-1 Aqueous 1,1-Dichloroethane 8260D 1.9 ug/L 155 054 MW-1 Aqueous cis- 1,2-Dichloroethene 8260D 0.89 ug/L 155 054 MW-1 Aqueous 1,4-Dioxane 8260D (SIM) 69 ug/L 157 054 MW-1 Aqueous Barium 6020B 140 ug/L 158 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 13 of 331 Detection Summary (Continued) Lot Number: XD27004 Sample Sample ID Matrix Parameter Method Result Q Units Page 054 MW-1 Aqueous Cobalt 6020B 12 ug/L 158 054 MW-1 Aqueous Copper 6020B 2.3 J ug/L 158 054 MW-1 Aqueous Lead 6020B 1.3 ug/L 158 054 MW-1 Aqueous Nickel 6020B 29 ug/L 158 054 MW-1 Aqueous Vanadium 6020B 2.7 J ug/L 158 055 MW-G Aqueous Chlorobenzene 8260D 2.5 ug/L 159 055 MW-G Aqueous Chloroethane 8260D 1.2 ug/L 159 055 MW-G Aqueous 1,4-Dichlorobenzene 8260D 1.3 ug/L 159 055 MW-G Aqueous 1,1-Dichloroethane 8260D 1.8 ug/L 159 055 MW-G Aqueous 1,2-Dichloropropane 8260D 0.52 ug/L 159 055 MW-G Aqueous Vinyl chloride 8260D 0.76 ug/L 160 055 MW-G Aqueous 1,4-Dioxane 8260D (SIM) 88 ug/L 161 055 MW-G Aqueous Arsenic 6020B 3.3 ug/L 162 055 MW-G Aqueous Barium 6020B 300 ug/L 162 055 MW-G Aqueous Cobalt 6020B 28 ug/L 162 055 MW-G Aqueous Nickel 6020B 35 ug/L 162 055 MW-G Aqueous Selenium 6020B 1.7 J ug/L 162 056 MW-10 Aqueous Benzene 8260D 1.0 ug/L 163 056 MW-10 Aqueous Chlorobenzene 8260D 31 ug/L 163 056 MW-10 Aqueous 1,2-Dichlorobenzene 8260D 0.75 ug/L 163 056 MW-10 Aqueous 1,4-Dichlorobenzene 8260D 4.8 ug/L 163 056 MW-10 Aqueous 1,4-Dioxane 8260D (SIM) 71 ug/L 165 056 MW-10 Aqueous Arsenic 6020B 41 ug/L 166 056 MW-10 Aqueous Barium 6020B 150 ug/L 166 056 MW-10 Aqueous Beryllium 6020B 0.74 ug/L 166 056 MW-10 Aqueous Chromium 6020B 6.1 ug/L 166 056 MW-10 Aqueous Cobalt 6020B 27 ug/L 166 056 MW-10 Aqueous Copper 6020B 2.1 J ug/L 166 056 MW-10 Aqueous Lead 6020B 1.2 ug/L 166 056 MW-10 Aqueous Nickel 6020B 130 ug/L 166 056 MW-10 Aqueous Selenium 6020B 2.3 J ug/L 166 056 MW-10 Aqueous Vanadium 6020B 6.9 ug/L 166 056 MW-10 Aqueous Zinc 6020B 8.2 J ug/L 166 057 MW-5 Aqueous Chlorobenzene 8260D 4.8 ug/L 167 057 MW-5 Aqueous 1,4-Dichlorobenzene 8260D 2.4 ug/L 167 057 MW-5 Aqueous 1,4-Dioxane 8260D (SIM) 42 ug/L 169 057 MW-5 Aqueous Barium 6020B 86 ug/L 170 057 MW-5 Aqueous Beryllium 6020B 0.19 J ug/L 170 057 MW-5 Aqueous Chromium 6020B 3.4 J ug/L 170 057 MW-5 Aqueous Cobalt 6020B 5.2 ug/L 170 057 MW-5 Aqueous Copper 6020B 5.2 ug/L 170 057 MW-5 Aqueous Lead 6020B 1.7 ug/L 170 057 MW-5 Aqueous Nickel 6020B 19 ug/L 170 057 MW-5 Aqueous Vanadium 6020B 7.3 ug/L 170 057 MW-5 Aqueous Zinc 6020B 11 ug/L 170 058 MW-11 Aqueous 1,4-Dioxane 8260D (SIM) 5.1 ug/L 173 058 MW-11 Aqueous Barium 6020B 140 ug/L 174 058 MW-11 Aqueous Cobalt 6020B 8.7 ug/L 174 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 14 of 331 Detection Summary (Continued) Lot Number: XD27004 Sample Sample ID Matrix Parameter Method Result Q Units Page 058 MW-11 Aqueous Copper 6020B 1.7 J ug/L 174 058 MW-11 Aqueous Nickel 6020B 8.6 ug/L 174 058 MW-11 Aqueous Zinc 6020B 25 ug/L 174 059 MW-7 Aqueous Benzene 8260D 1.1 ug/L 175 059 MW-7 Aqueous Chlorobenzene 8260D 28 ug/L 175 059 MW-7 Aqueous 1,2-Dichlorobenzene 8260D 0.72 ug/L 175 059 MW-7 Aqueous 1,4-Dichlorobenzene 8260D 8.0 ug/L 175 059 MW-7 Aqueous 1,4-Dioxane 8260D (SIM) 110 ug/L 177 059 MW-7 Aqueous Arsenic 6020B 8.9 ug/L 178 059 MW-7 Aqueous Barium 6020B 810 ug/L 178 059 MW-7 Aqueous Cobalt 6020B 35 ug/L 178 059 MW-7 Aqueous Nickel 6020B 110 ug/L 178 059 MW-7 Aqueous Selenium 6020B 29 ug/L 178 059 MW-7 Aqueous Vanadium 6020B 5.2 ug/L 178 060 MW-8a Aqueous Antimony 6020B 0.51 J ug/L 182 060 MW-8a Aqueous Arsenic 6020B 1.3 J ug/L 182 060 MW-8a Aqueous Barium 6020B 58 ug/L 182 060 MW-8a Aqueous Cadmium 6020B 0.43 J ug/L 182 060 MW-8a Aqueous Cobalt 6020B 21 ug/L 182 060 MW-8a Aqueous Copper 6020B 29 ug/L 182 060 MW-8a Aqueous Lead 6020B 2.6 ug/L 182 060 MW-8a Aqueous Nickel 6020B 180 ug/L 182 060 MW-8a Aqueous Zinc 6020B 570 ug/L 182 061 DUP Aqueous 1,4-Dioxane 8260D (SIM) 4.2 ug/L 185 061 DUP Aqueous Barium 6020B 140 ug/L 186 061 DUP Aqueous Cobalt 6020B 9.2 ug/L 186 061 DUP Aqueous Copper 6020B 1.4 J ug/L 186 061 DUP Aqueous Nickel 6020B 8.2 ug/L 186 061 DUP Aqueous Zinc 6020B 24 ug/L 186 064 CD-9 Aqueous Alkalinity @ pH 4.5 su SM 232013- 120 mg CaCO3/L 195 064 CD-9 Aqueous Chloride 9056A 5000 ug/L 195 064 CD-9 Aqueous Sulfate 9056A 6800 ug/L 195 064 CD-9 Aqueous TDS SM 2540C- 170000 ug/L 195 064 CD-9 Aqueous 1,1-Dichloroethane 8260D 0.48 HJ ug/L 196 064 CD-9 Aqueous cis- 1,2-Dichloroethene 8260D 1.7 H ug/L 196 064 CD-9 Aqueous Barium 6020B 76 ug/L 199 064 CD-9 Aqueous Iron 6020B 92 ug/L 199 064 CD-9 Aqueous Manganese 6020B 4.5 J ug/L 199 064 CD-9 Aqueous Vanadium 6020B 3.0 J ug/L 199 (418 detections) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 15 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-001 Description: MW-L Matrix: Aqueous Date Sampled:04/26/2022 0840 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/28/2022 1628 TAD 39755 1 (BOD, 5 day) SM 521OB-2011 1 05/02/2022 1648 CLL 04/27/2022 1853 39567 1 (Chloride) 9056A 1 04/28/2022 1308 CAW 39868 1 (CO2 (calcula) SM 4500-CO2 D 1 04/28/2022 1628 TAD 1 (COD) SM 5220D-2011 1 04/29/2022 1811 KKP 39723 1 (Nitrate - N) 9056A 1 04/28/2022 1308 CAW 39879 2 (Nitrate - N) 9056A 1 05/03/2022 0215 CAW 40227 1 (Sulfate) 9056A 1 04/28/2022 1308 CAW 39853 1 (Sulfide) SM 4500-S2 F-2011 1 04/29/2022 1211 SJL 39710 1 (TOC) SM 531 OC-2011 1 05/06/2022 2124 DMA 40686 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su BOD, 5 day Chloride CO2 (calculation) COD Sulfate Nitrate - N Sulfide Nitrate - N TOC SM 2320B-2011 45 20 20 mg CaCO3/L 1 SM 521OB-2011 ND 2000 180 ug/L 1 9056A 3000 1000 250 ug/L 1 124-38-9 SM 4500-CO2 D 120000 27000 27000 ug/L 1 SM 5220D-2011 ND S 20000 20000 ug/L 1 9056A 610 J 1000 250 ug/L 1 9056A 88 BH 20 5.0 ug/L 1 18496-25-8 SM 4500-S2 F-2 ND 1000 1000 ug/L 1 9056A 88 BHS 20 5.0 ug/L 2 SM 531OC-2011 ND 1000 1000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 16 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-001 Description: MW-L Matrix: Aqueous Date Sampled:04/26/2022 0840 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/02/20221638 JWO 40083 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 26 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 2.4 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 8.3 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 1.0 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 16 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 7.5 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 1.6 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 17 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-001 Description: MW-L Matrix: Aqueous Date Sampled:04/26/2022 0840 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/02/20221638 JWO 40083 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 98 70-130 122 70-130 103 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 18 of 331 Dissolved Gases Client:CDM Smith Laboratory ID:XD27004-001 Description: MW-L Matrix: Aqueous Date Sampled:04/26/2022 0840 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 05/06/2022 1423 JM1 40722 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane Ethene Methane 74-84-0 RSK - 175 ND 10 2.5 ug/L 1 74-85-1 RSK - 175 ND 10 2.5 ug/L 1 74-82-8 RSK - 175 ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 19 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-002 Description: MW-3 Matrix: Aqueous Date Sampled:04/26/2022 1005 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/28/2022 1634 TAD 39755 1 (BOD, 5 day) SM 521OB-2011 1 05/02/2022 1649 CLL 04/27/2022 1855 39567 1 (Chloride) 9056A 1 04/28/2022 1327 CAW 39868 1 (CO2 (calcula) SM 4500-CO2 D 1 04/28/2022 1634 TAD 1 (COD) SM 5220D-2011 1 04/29/2022 1812 KKP 39723 1 (Nitrate - N) 9056A 1 04/28/2022 1327 CAW 39879 2 (Nitrate - N) 9056A 10 04/29/2022 2359 CAW 40136 2 (Sulfate) 9056A 10 04/29/2022 2359 CAW 40132 1 (Sulfide) SM 4500-S2 F-2011 1 04/29/2022 1211 SJL 39710 1 (TOC) SM 531 OC-2011 1 05/06/2022 2202 DMA 40686 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su BOD, 5 day Chloride CO2 (calculation) COD Sulfate Nitrate - N Sulfide Nitrate - N TOC SM 2320B-2011 100 20 20 mg CaCO3/L 1 SM 521OB-2011 ND 2000 180 ug/L 1 9056A 5500 1000 250 ug/L 1 124-38-9 SM 4500-CO2 D 180000 27000 27000 ug/L 1 SM 5220D-2011 ND 20000 20000 ug/L 1 9056A 2900 J 10000 2500 ug/L 2 9056A ND H 20 5.0 ug/L 1 18496-25-8 SM 4500-S2 F-2 ND S 1000 1000 ug/L 1 9056A ND H 200 50 ug/L 2 SM 531OC-2011 ND 1000 1000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 20 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-002 Description: MW-3 Matrix: Aqueous Date Sampled:04/26/2022 1005 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/02/20221703 JWO 40083 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 21 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 1.4 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 9.5 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 9.7 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 6.0 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.55 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 21 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-002 Description: MW-3 Matrix: Aqueous Date Sampled:04/26/2022 1005 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/02/20221703 JWO 40083 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 120 70-130 103 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 22 of 331 Dissolved Gases Client:CDM Smith Laboratory ID:XD27004-002 Description: MW-3 Matrix: Aqueous Date Sampled:04/26/2022 1005 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 05/06/2022 1439 JM1 40722 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane Ethene Methane 74-84-0 RSK - 175 ND 10 2.5 ug/L 1 74-85-1 RSK - 175 ND 10 2.5 ug/L 1 74-82-8 RSK - 175 ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 23 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-003 Description: MW-E deep Matrix: Aqueous Date Sampled:04/26/2022 1105 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/28/2022 1643 TAD 39755 1 (BOD, 5 day) SM 521OB-2011 1 05/02/2022 1651 CLL 04/27/2022 1858 39567 1 (Chloride) 9056A 1 04/28/2022 1346 CAW 39868 1 (CO2 (calcula) SM 4500-CO2 D 1 04/28/2022 1643 TAD 1 (COD) SM 5220D-2011 1 04/29/2022 1812 KKP 39723 1 (Nitrate - N) 9056A 1 04/28/2022 1346 CAW 39879 2 (Nitrate - N) 9056A 10 04/30/2022 0018 CAW 40136 2 (Sulfate) 9056A 10 04/30/2022 0018 CAW 40132 1 (Sulfide) SM 4500-S2 F-2011 1 04/29/2022 1211 SJL 39710 1 (TOC) SM 531 OC-2011 1 05/06/2022 2215 DMA 40686 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su BOD, 5 day Chloride CO2 (calculation) COD Sulfate Nitrate - N Sulfide Nitrate - N TOC SM 2320B-2011 450 20 20 mg CaCO3/L 1 SM 521OB-2011 6600 2000 180 ug/L 1 9056A 49000 1000 250 ug/L 1 124-38-9 SM 4500-CO2 D 520000 27000 27000 ug/L 1 SM 5220D-2011 ND 20000 20000 ug/L 1 9056A ND 10000 2500 ug/L 2 9056A 9600 BHE 20 5.0 ug/L 1 18496-25-8 SM 4500-S2 F-2 ND 1000 1000 ug/L 1 9056A ND H 200 50 ug/L 2 SM 531OC-2011 2800 1000 1000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 24 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-003 Description: MW-E deep Matrix: Aqueous Date Sampled:04/26/2022 1105 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/02/20221728 JWO 40083 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.63 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 1.4 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 14 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 8.7 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.67 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 1.1 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.84 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 25 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-003 Description: MW-E deep Matrix: Aqueous Date Sampled:04/26/2022 1105 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/02/20221728 JWO 40083 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 96 70-130 118 70-130 100 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 26 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-003 Description: MW-E deep Matrix: Aqueous Date Sampled:04/26/2022 1105 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/29/2022 1728 JWO 39871 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 7.0 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 97 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 27 of 331 Dissolved Gases Client:CDM Smith Laboratory ID:XD27004-003 Description: MW-E deep Matrix: Aqueous Date Sampled:04/26/2022 1105 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 05/06/2022 1455 JM1 40722 2 RSK - 175 5 05/10/2022 1754 JM1 41098 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 6.3 J 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 ND 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 8200 BE 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 28 of 331 Dissolved Gases Client:CDM Smith Laboratory ID:XD27004-003 Description: MW-E deep Matrix: Aqueous Date Sampled:04/26/2022 1105 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 05/06/2022 1455 JM1 40722 2 RSK - 175 5 05/10/2022 1754 JM1 41098 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 ND 50 13 ug/L 2 Ethene 74-85-1 RSK - 175 ND 50 13 ug/L 2 Methane 74-82-8 RSK - 175 8800 B 50 13 ug/L 2 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 29 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-004 Description: MW-E REP Matrix: Aqueous Date Sampled:04/26/2022 1140 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/28/2022 1652 TAD 39755 1 (BOD, 5 day) SM 521OB-2011 1 05/02/2022 1700 CLL 04/27/2022 1949 39567 1 (Chloride) 9056A 1 04/28/2022 1405 CAW 39868 1 (CO2 (calcula) SM 4500-CO2 D 1 04/28/2022 1652 TAD 1 (COD) SM 5220D-2011 1 04/29/2022 1812 KKP 39723 1 (Nitrate - N) 9056A 1 04/28/2022 1405 CAW 39879 2 (Nitrate - N) 9056A 10 04/30/2022 0037 CAW 40136 2 (Sulfate) 9056A 10 04/30/2022 0037 CAW 40132 1 (Sulfide) SM 4500-S2 F-2011 1 04/29/2022 1211 SJL 39710 1 (TOC) SM 531 OC-2011 1 05/06/2022 2254 DMA 40686 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su BOD, 5 day Chloride CO2 (calculation) COD Sulfate Nitrate - N Sulfide Nitrate - N TOC SM 2320B-2011 560 20 20 mg CaCO3/L 1 SM 521OB-2011 ND 2000 180 ug/L 1 9056A 64000 1000 250 ug/L 1 124-38-9 SM 4500-CO2 D 720000 27000 27000 ug/L 1 SM 5220D-2011 ND 20000 20000 ug/L 1 9056A 2900 J 10000 2500 ug/L 2 9056A ND H 20 5.0 ug/L 1 18496-25-8 SM 4500-S2 F-2 ND 1000 1000 ug/L 1 9056A ND H 200 50 ug/L 2 SM 531OC-2011 3900 1000 1000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 30 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-004 Description: MW-E REP Matrix: Aqueous Date Sampled:04/26/2022 1140 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/02/20221753 JWO 40083 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.56 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 3.5 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 5.4 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 15 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 1.3 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.97 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 12 0.50 0.40 ug/L 1 trans-1,2-Dichloroethene 156-60-5 8260D 0.47 J 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.82 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 31 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-004 Description: MW-E REP Matrix: Aqueous Date Sampled:04/26/2022 1140 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/02/20221753 JWO 40083 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 3.4 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 119 70-130 102 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 32 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-004 Description: MW-E REP Matrix: Aqueous Date Sampled:04/26/2022 1140 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/29/2022 1752 JWO 39871 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 3.6 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 92 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 33 of 331 Dissolved Gases Client:CDM Smith Laboratory ID:XD27004-004 Description: MW-E REP Matrix: Aqueous Date Sampled:04/26/2022 1140 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 05/06/2022 1511 JM1 40722 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 ND 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 ND 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 280 B 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 34 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-005 Description: AMW-1s Matrix: Aqueous Date Sampled:04/26/2022 1305 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/28/2022 1657 TAD 39755 1 (BOD, 5 day) SM 521OB-2011 1 05/02/2022 1701 CLL 04/27/2022 1912 39567 1 (Chloride) 9056A 1 04/28/2022 1424 CAW 39868 1 (CO2 (calcula) SM 4500-CO2 D 1 04/28/2022 1657 TAD 1 (COD) SM 5220D-2011 1 04/29/2022 1812 KKP 39723 1 (Nitrate - N) 9056A 1 04/28/2022 1424 CAW 39879 2 (Nitrate - N) 9056A 10 04/30/2022 0056 CAW 40136 2 (Sulfate) 9056A 10 04/30/2022 0056 CAW 40132 1 (Sulfide) SM 4500-S2 F-2011 1 04/29/2022 1211 SJL 39710 1 (TOC) SM 531 OC-2011 1 05/06/2022 2307 DMA 40686 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su BOD, 5 day Chloride CO2 (calculation) COD Sulfate Nitrate - N Sulfide Nitrate - N TOC SM 2320B-2011 110 20 20 mg CaCO3/L 1 SM 521OB-2011 ND 2000 180 ug/L 1 9056A 3500 1000 250 ug/L 1 124-38-9 SM 4500-CO2 D 340000 27000 27000 ug/L 1 SM 5220D-2011 ND 20000 20000 ug/L 1 9056A ND 10000 2500 ug/L 2 9056A ND H 20 5.0 ug/L 1 18496-25-8 SM 4500-S2 F-2 ND 1000 1000 ug/L 1 9056A 53 BHJ 200 50 ug/L 2 SM 531OC-2011 ND 1000 1000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 35 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-005 Description: AMW-1s Matrix: Aqueous Date Sampled:04/26/2022 1305 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/02/20221818 JWO 40083 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.55 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 1.5 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 36 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-005 Description: AMW-1s Matrix: Aqueous Date Sampled:04/26/2022 1305 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/02/20221818 JWO 40083 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 92 70-130 119 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 37 of 331 Dissolved Gases Client:CDM Smith Laboratory ID:XD27004-005 Description: AMW-1s Matrix: Aqueous Date Sampled:04/26/2022 1305 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 05/06/2022 1527 JM1 40722 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 ND 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 ND 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 1100 B 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 38 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-006 Description: AMW-1d Matrix: Aqueous Date Sampled:04/26/2022 1225 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/28/2022 1713 TAD 39755 1 (BOD, 5 day) SM 521OB-2011 1 05/02/2022 1703 CLL 04/27/2022 1915 39567 1 (Chloride) 9056A 1 04/28/2022 1443 CAW 39868 1 (CO2 (calcula) SM 4500-CO2 D 1 04/28/2022 1713 TAD 1 (COD) SM 5220D-2011 1 04/29/2022 1812 KKP 39723 1 (Nitrate - N) 9056A 1 04/28/2022 1443 CAW 39879 2 (Nitrate - N) 9056A 10 04/30/2022 0115 CAW 40136 2 (Sulfate) 9056A 10 04/30/2022 0115 CAW 40132 1 (Sulfide) SM 4500-S2 F-2011 1 04/29/2022 1211 SJL 39710 1 (TOC) SM 531 OC-2011 1 05/06/2022 2320 DMA 40686 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su BOD, 5 day Chloride CO2 (calculation) COD Sulfate Nitrate - N Sulfide Nitrate - N TOC SM 2320B-2011 230 20 20 mg CaCO3/L 1 SM 521OB-2011 ND 2000 180 ug/L 1 9056A 7400 1000 250 ug/L 1 124-38-9 SM 4500-CO2 D 340000 27000 27000 ug/L 1 SM 5220D-2011 ND 20000 20000 ug/L 1 9056A ND 10000 2500 ug/L 2 9056A 38 BH 20 5.0 ug/L 1 18496-25-8 SM 4500-S2 F-2 ND 1000 1000 ug/L 1 9056A ND H 200 50 ug/L 2 SM 531OC-2011 ND 1000 1000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 39 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-006 Description: AMW-1d Matrix: Aqueous Date Sampled:04/26/2022 1225 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/02/20221843 JWO 40083 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.96 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 1.9 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.86 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 11 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 8.0 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.44 J 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 2.2 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 40 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-006 Description: AMW-1d Matrix: Aqueous Date Sampled:04/26/2022 1225 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/02/20221843 JWO 40083 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 3.8 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 96 70-130 119 70-130 102 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 41 of 331 Dissolved Gases Client:CDM Smith Laboratory ID:XD27004-006 Description: AMW-1d Matrix: Aqueous Date Sampled:04/26/2022 1225 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 05/06/2022 1543 JM1 40722 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 ND 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 ND 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 2300 B 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 42 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-007 Description: AMW-2s Matrix: Aqueous Date Sampled:04/26/2022 1440 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/28/2022 1726 TAD 39755 1 (BOD, 5 day) SM 521OB-2011 1 05/02/2022 1705 CLL 04/27/2022 1921 39567 1 (Chloride) 9056A 1 04/28/2022 1502 CAW 39868 1 (CO2 (calcula) SM 4500-CO2 D 1 04/28/2022 1726 TAD 1 (COD) SM 5220D-2011 1 04/29/2022 1813 KKP 39723 1 (Nitrate - N) 9056A 1 04/28/2022 1502 CAW 39879 1 (Sulfate) 9056A 1 04/28/2022 1502 CAW 39853 1 (Sulfide) SM 4500-S2 F-2011 1 04/29/2022 1211 SJL 39710 1 (TOC) SM 531 OC-2011 1 05/10/2022 0121 DMA 40969 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 72 20 20 mg CaCO3/L 1 BOD, 5 day SM 521OB-2011 ND 2000 180 ug/L 1 Chloride 9056A 3100 1000 250 ug/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 230000 27000 27000 ug/L 1 COD SM 5220D-2011 ND 20000 20000 ug/L 1 Sulfate 9056A ND 1000 250 ug/L 1 Nitrate - N 9056A 370 BH 20 5.0 ug/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 ND 1000 1000 ug/L 1 TOC SM 531OC-2011 ND 1000 1000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 43 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-007 Description: AMW-2s Matrix: Aqueous Date Sampled:04/26/2022 1440 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221521 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 2.2 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 2.2 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.91 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.70 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 44 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-007 Description: AMW-2s Matrix: Aqueous Date Sampled:04/26/2022 1440 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221521 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 95 70-130 93 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 45 of 331 Dissolved Gases Client:CDM Smith Laboratory ID:XD27004-007 Description: AMW-2s Matrix: Aqueous Date Sampled:04/26/2022 1440 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 05/06/2022 1559 JM1 40722 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 ND 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 ND 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 3.8 BJ 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 46 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-008 Description: AMW-2d Matrix: Aqueous Date Sampled:04/26/2022 1400 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/28/2022 1731 TAD 39755 1 (BOD, 5 day) SM 521OB-2011 1 05/02/2022 1706 CLL 04/27/2022 1923 39567 1 (Chloride) 9056A 1 04/28/2022 1655 CAW 39868 1 (CO2 (calcula) SM 4500-CO2 D 1 04/28/2022 1731 TAD 1 (COD) SM 5220D-2011 1 04/29/2022 1813 KKP 39723 1 (Nitrate - N) 9056A 1 04/28/2022 1655 CAW 39879 2 (Nitrate - N) 9056A 10 04/30/2022 0134 CAW 40136 2 (Sulfate) 9056A 10 04/30/2022 0134 CAW 40132 1 (Sulfide) SM 4500-S2 F-2011 1 04/29/2022 1211 SJL 39710 1 (TOC) SM 531 OC-2011 1 05/10/2022 0135 DMA 40969 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su BOD, 5 day Chloride CO2 (calculation) COD Sulfate Nitrate - N Sulfide Nitrate - N TOC SM 2320B-2011 140 20 20 mg CaCO3/L 1 SM 521OB-2011 ND 2000 180 ug/L 1 9056A 3200 1000 250 ug/L 1 124-38-9 SM 4500-CO2 D 360000 27000 27000 ug/L 1 SM 5220D-2011 ND 20000 20000 ug/L 1 9056A ND 10000 2500 ug/L 2 9056A ND H 20 5.0 ug/L 1 18496-25-8 SM 4500-S2 F-2 ND 1000 1000 ug/L 1 9056A 58 BHJ 200 50 ug/L 2 SM 531OC-2011 ND 1000 1000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 47 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-008 Description: AMW-2d Matrix: Aqueous Date Sampled:04/26/2022 1400 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221544 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 1.0 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 1.2 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 15 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 1.0 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 15 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 1.0 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 2.7 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 6.9 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 48 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-008 Description: AMW-2d Matrix: Aqueous Date Sampled:04/26/2022 1400 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221544 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 92 70-130 91 70-130 97 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 49 of 331 Dissolved Gases Client:CDM Smith Laboratory ID:XD27004-008 Description: AMW-2d Matrix: Aqueous Date Sampled:04/26/2022 1400 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 05/06/2022 1615 JM1 40722 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 ND 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 ND 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 2.8 BJ 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 50 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-008 Description: AMW-2d Matrix: Aqueous Date Sampled:04/26/2022 1400 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/29/2022 1422 BPK Prep Date Batch 04/28/2022 0906 39642 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 65 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.21 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.9 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 51 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-009 Description: MW-L deep Matrix: Aqueous Date Sampled:04/26/2022 0910 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221607 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.69 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 52 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-009 Description: MW-L deep Matrix: Aqueous Date Sampled:04/26/2022 0910 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221607 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 93 70-130 95 70-130 96 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 53 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-009 Description: MW-L deep Matrix: Aqueous Date Sampled:04/26/2022 0910 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/29/2022 1425 BPK Prep Date Batch 04/28/2022 0906 39642 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 24 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.4 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 54 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-010 Description: MW- 3 deep Matrix: Aqueous Date Sampled:04/26/2022 0935 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221630 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.85 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 55 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-010 Description: MW- 3 deep Matrix: Aqueous Date Sampled:04/26/2022 0935 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221630 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 96 70-130 94 70-130 97 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 56 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-010 Description: MW- 3 deep Matrix: Aqueous Date Sampled:04/26/2022 0935 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/29/2022 1429 BPK Prep Date Batch 04/28/2022 0906 39642 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 50 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 3.5 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 57 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-011 Description: CD-1s Matrix: Aqueous Date Sampled:04/26/2022 1550 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/28/2022 1736 TAD 39755 1 (BOD, 5 day) SM 521OB-2011 1 05/02/2022 1708 CLL 04/27/2022 1926 39567 1 (Chloride) 9056A 1 04/28/2022 1714 CAW 39868 1 (CO2 (calcula) SM 4500-CO2 D 1 04/28/2022 1736 TAD 1 (COD) SM 5220D-2011 1 04/29/2022 1813 KKP 39723 1 (Nitrate - N) 9056A 1 04/28/2022 1714 CAW 39879 1 (Sulfate) 9056A 1 04/28/2022 1714 CAW 39853 1 (Sulfide) SM 4500-S2 F-2011 1 04/29/2022 1211 SJL 39710 1 (TDS) SM 2540C-2015 1 05/03/2022 1738 CVR 40264 1 (TOC) SM 531 OC-2011 1 05/10/2022 0147 DMA 40969 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 52 20 20 mg CaCO3/L 1 BOD, 5 day SM 521OB-2011 ND 2000 180 ug/L 1 Chloride 9056A 9200 1000 250 ug/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 100000 27000 27000 ug/L 1 COD SM 5220D-2011 ND 20000 20000 ug/L 1 Sulfate 9056A 1000 1000 250 ug/L 1 Nitrate - N 9056A 290 BH 20 5.0 ug/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 ND 1000 1000 ug/L 1 TDS SM 2540C-2015 120000 25000 25000 ug/L 1 TOC SM 531OC-2011 ND 1000 1000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 58 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-011 Description: CD-1s Matrix: Aqueous Date Sampled:04/26/2022 1550 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221654 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 59 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-011 Description: CD-1s Matrix: Aqueous Date Sampled:04/26/2022 1550 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221654 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 96 70-130 Toluene-d8 98 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 60 of 331 Dissolved Gases Client:CDM Smith Laboratory ID:XD27004-011 Description: CD-1s Matrix: Aqueous Date Sampled:04/26/2022 1550 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 05/06/2022 1631 JM1 40722 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane Ethene Methane 74-84-0 RSK - 175 ND 10 2.5 ug/L 1 74-85-1 RSK - 175 ND 10 2.5 ug/L 1 74-82-8 RSK - 175 ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 61 of 331 CVAA Client:CDM Smith Laboratory ID:XD27004-011 Description: CD-1s Matrix: Aqueous Date Sampled:04/26/2022 1550 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/29/2022 0808 JA132 04/29/2022 0201 39629 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.20 0.091 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 62 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-011 Description: CD-1s Matrix: Aqueous Date Sampled:04/26/2022 1550 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/29/2022 1432 BPK Prep Date Batch 04/28/2022 0906 39642 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 32 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 200 50 13 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 13 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 4.0 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 63 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-012 Description: CD-1d Matrix: Aqueous Date Sampled:04/26/2022 1620 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221717 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 64 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-012 Description: CD-1d Matrix: Aqueous Date Sampled:04/26/2022 1620 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221717 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 93 70-130 1,2-Dichloroethane-d4 95 70-130 Toluene-d8 96 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 65 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-013 Description: DUP Matrix: Aqueous Date Sampled:04/26/2022 0800 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221740 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 18 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 1.6 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 7.9 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.64 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 10 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 5.1 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 1.1 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 66 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-013 Description: DUP Matrix: Aqueous Date Sampled:04/26/2022 0800 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221740 JWO 40225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 88 70-130 93 70-130 95 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 67 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-013 Description: DUP Matrix: Aqueous Date Sampled:04/26/2022 0800 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/29/2022 1436 BPK Prep Date Batch 04/28/2022 0906 39642 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 24 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 4.7 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 68 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-014 Description: Trip Blank Matrix: Aqueous Date Sampled:04/26/2022 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221153 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 69 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-014 Description: Trip Blank Matrix: Aqueous Date Sampled:04/26/2022 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221153 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 96 70-130 119 70-130 101 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 70 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-015 Description: MW-H Matrix: Aqueous Date Sampled:04/26/2022 1334 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221308 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 71 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-015 Description: MW-H Matrix: Aqueous Date Sampled:04/26/2022 1334 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221308 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 96 70-130 121 70-130 103 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 72 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-015 Description: MW-H Matrix: Aqueous Date Sampled:04/26/2022 1334 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/29/2022 1817 JWO 39871 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 94 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 73 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-015 Description: MW-H Matrix: Aqueous Date Sampled:04/26/2022 1334 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/29/2022 1439 BPK Prep Date Batch 04/28/2022 0906 39642 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 39 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.4 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.3 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.40 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.9 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.3 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 3.7 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 74 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-016 Description: MW-X Matrix: Aqueous Date Sampled:04/26/2022 1150 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221334 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 75 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-016 Description: MW-X Matrix: Aqueous Date Sampled:04/26/2022 1150 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221334 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 96 70-130 120 70-130 101 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 76 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-016 Description: MW-X Matrix: Aqueous Date Sampled:04/26/2022 1150 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/29/2022 1842 JWO 39871 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 95 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 77 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-016 Description: MW-X Matrix: Aqueous Date Sampled:04/26/2022 1150 Project Name: Cabarrus County Unit 2 & Date Received:04/27/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/29/2022 1443 BPK Prep Date Batch 04/28/2022 0906 39642 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 25 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.7 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 78 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-017 Description: MW-L Matrix: Aqueous Date Sampled:04/27/2022 0815 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/02/2022 1421 BNW Prep Date Batch 04/30/2022 1038 39927 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 4.0 1.0 ug/L 1 Arsenic 7440-38-2 6020B ND 4.0 2.5 ug/L 1 Barium 7440-39-3 6020B 110 10 2.5 ug/L 1 Beryllium 7440-41-7 6020B 0.70 J 0.80 0.30 ug/L 1 Cadmium 7440-43-9 6020B ND 1.0 0.25 ug/L 1 Chromium 7440-47-3 6020B 5.9 J 10 2.5 ug/L 1 Cobalt 7440-48-4 6020B 6.2 J 10 2.5 ug/L 1 Copper 7440-50-8 6020B 3.5 J 10 2.5 ug/L 1 Lead 7439-92-1 6020B 2.8 2.0 0.50 ug/L 1 Nickel 7440-02-0 6020B 11 10 2.5 ug/L 1 Selenium 7782-49-2 6020B ND 10 2.5 ug/L 1 Silver 7440-22-4 6020B ND 2.0 0.50 ug/L 1 Thallium 7440-28-0 6020B ND 1.0 0.30 ug/L 1 Vanadium 7440-62-2 6020B 28 10 5.0 ug/L 1 Zinc 7440-66-6 6020B 29 20 5.0 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 79 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-018 Description: MW-3 Matrix: Aqueous Date Sampled:04/27/2022 0835 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/02/2022 1424 BNW Prep Date Batch 04/30/2022 1038 39927 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 32 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 80 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-019 Description: MW-M Matrix: Aqueous Date Sampled:04/27/2022 0900 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221359 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 1.4 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 0.44 J 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 81 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-019 Description: MW-M Matrix: Aqueous Date Sampled:04/27/2022 0900 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221359 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 94 70-130 122 70-130 100 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 82 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-019 Description: MW-M Matrix: Aqueous Date Sampled:04/27/2022 0900 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/29/2022 1906 JWO 39871 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 1.5 J 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 96 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 83 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-019 Description: MW-M Matrix: Aqueous Date Sampled:04/27/2022 0900 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/02/2022 1435 BNW Prep Date Batch 04/30/2022 1038 39927 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 33 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.3 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.47 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.7 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 84 of 331 Semivolatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-020 Description: AMW-2d Matrix: Aqueous Date Sampled:04/27/2022 0915 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3520C 8270D 1 05/07/2022 0224 SCD 05/04/2022 1530 40389 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run bis(2-Ethylhexyl)phthalate 117-81-7 8270D 3.2 J 4.0 0.50 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 2-Fluorobiphenyl 2-Fluorophenol Nitrobenzene-d5 Phenol-d5 Terphenyl-d14 2,4,6-Tribromophenol 78 37-129 47 24-127 100 38-127 58 28-128 94 10-148 58 35-144 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 85 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-021 Description: AMW-2s Matrix: Aqueous Date Sampled:04/27/2022 0930 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/02/2022 1438 BNW Prep Date Batch 04/30/2022 1038 39927 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 43 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.75 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.88 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 2.0 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 4.3 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 13 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 86 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-022 Description: MW-H deep Matrix: Aqueous Date Sampled:04/27/2022 0950 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221424 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 87 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-022 Description: MW-H deep Matrix: Aqueous Date Sampled:04/27/2022 0950 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221424 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 120 70-130 102 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 88 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-022 Description: MW-H deep Matrix: Aqueous Date Sampled:04/27/2022 0950 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/02/2022 1442 BNW Prep Date Batch 04/30/2022 1038 39927 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.91 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 40 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.26 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 7.7 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 89 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-023 Description: AMW-1d Matrix: Aqueous Date Sampled:04/27/2022 1010 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/02/2022 1445 BNW Prep Date Batch 04/30/2022 1038 39927 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.3 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 130 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.17 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.4 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 6.9 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 4.0 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.4 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 13 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 13 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 90 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-024 Description: AMW-1s Matrix: Aqueous Date Sampled:04/27/2022 1030 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/02/2022 1449 BNW Prep Date Batch 04/30/2022 1038 39927 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 75 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 1.1 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.4 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 7.8 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.9 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 4.4 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 7.9 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 18 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 91 of 331 Semivolatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-025 Description: MW-E deep Matrix: Aqueous Date Sampled:04/27/2022 1100 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3520C 8270D 1 05/07/2022 0248 SCD 05/04/2022 1530 40389 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run bis(2-Ethylhexyl)phthalate 117-81-7 8270D 2.8 J 4.0 0.50 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 2-Fluorobiphenyl 2-Fluorophenol Nitrobenzene-d5 Phenol-d5 Terphenyl-d14 2,4,6-Tribromophenol 73 37-129 50 24-127 92 38-127 66 28-128 85 10-148 58 35-144 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 92 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-025 Description: MW-E deep Matrix: Aqueous Date Sampled:04/27/2022 1100 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A 2 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/02/2022 1452 BNW 6020B 5 05/04/2022 1009 BNW Prep Date Batch 04/30/2022 1038 39927 04/30/2022 1038 39927 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.7 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 2200 25 6.3 ug/L 2 Beryllium 7440-41-7 6020B 0.35 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.49 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.8 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 30 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 8.3 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 48 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 16 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.6 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 25 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 93 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-026 Description: MW-E Rep Matrix: Aqueous Date Sampled:04/27/2022 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/02/2022 1456 BNW Prep Date Batch 04/30/2022 1038 39927 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 410 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.43 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.0 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 9.9 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 2.4 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 6.8 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 16 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 6.5 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 19 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 94 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-027 Description: MW-1 Matrix: Aqueous Date Sampled:04/27/2022 1200 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221449 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.66 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.55 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 95 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-027 Description: MW-1 Matrix: Aqueous Date Sampled:04/27/2022 1200 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221449 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 95 70-130 122 70-130 100 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 96 of 331 Semivolatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-027 Description: MW-1 Matrix: Aqueous Date Sampled:04/27/2022 1200 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3520C 8270D 1 05/07/2022 0313 SCD 05/04/2022 1530 40389 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run bis(2-Ethylhexyl)phthalate 117-81-7 8270D 2.6 J 4.0 0.50 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 2-Fluorobiphenyl 2-Fluorophenol Nitrobenzene-d5 Phenol-d5 Terphenyl-d14 2,4,6-Tribromophenol 71 37-129 44 24-127 87 38-127 59 28-128 87 10-148 52 35-144 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 97 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-027 Description: MW-1 Matrix: Aqueous Date Sampled:04/27/2022 1200 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/02/2022 1459 BNW Prep Date Batch 04/30/2022 1038 39927 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.59 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 12 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.1 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 2.8 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 2.9 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 98 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-028 Description: MW-F Matrix: Aqueous Date Sampled:04/27/2022 1215 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221514 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 99 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-028 Description: MW-F Matrix: Aqueous Date Sampled:04/27/2022 1215 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221514 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 93 70-130 121 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 100 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-028 Description: MW-F Matrix: Aqueous Date Sampled:04/27/2022 1215 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/03/2022 1609 KJH 40214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 14 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 99 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 101 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-028 Description: MW-F Matrix: Aqueous Date Sampled:04/27/2022 1215 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1730 BNW Prep Date Batch 04/30/2022 1125 39935 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 1.5 J 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 220 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.5 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 9.9 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 102 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-029 Description: MW-B Matrix: Aqueous Date Sampled:04/27/2022 1230 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221539 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 103 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-029 Description: MW-B Matrix: Aqueous Date Sampled:04/27/2022 1230 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221539 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 93 70-130 119 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 104 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-029 Description: MW-B Matrix: Aqueous Date Sampled:04/27/2022 1230 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/03/2022 1633 KJH 40214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 13 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 100 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 105 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-029 Description: MW-B Matrix: Aqueous Date Sampled:04/27/2022 1230 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1733 BNW Prep Date Batch 04/30/2022 1125 39935 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 120 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 11 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 3.9 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 106 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-030 Description: MW-K Matrix: Aqueous Date Sampled:04/27/2022 1253 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221605 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 1.9 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 107 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-030 Description: MW-K Matrix: Aqueous Date Sampled:04/27/2022 1253 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221605 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 121 70-130 103 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 108 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-030 Description: MW-K Matrix: Aqueous Date Sampled:04/27/2022 1253 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1744 BNW Prep Date Batch 04/30/2022 1125 39935 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 22 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 2.0 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 2.8 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 109 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-031 Description: MW-D Matrix: Aqueous Date Sampled:04/27/2022 1305 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221630 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 3.9 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.71 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.57 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 4.4 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 6.6 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.68 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 110 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-031 Description: MW-D Matrix: Aqueous Date Sampled:04/27/2022 1305 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221630 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 1.7 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 100 70-130 121 70-130 101 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 111 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-031 Description: MW-D Matrix: Aqueous Date Sampled:04/27/2022 1305 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1747 BNW Prep Date Batch 04/30/2022 1125 39935 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 1.5 J 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 270 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 16 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 30 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 112 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-032 Description: MW-C Matrix: Aqueous Date Sampled:04/27/2022 1325 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221655 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 113 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-032 Description: MW-C Matrix: Aqueous Date Sampled:04/27/2022 1325 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221655 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 93 70-130 119 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 114 of 331 Semivolatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-032 Description: MW-C Matrix: Aqueous Date Sampled:04/27/2022 1325 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3520C 8270D 1 05/07/2022 0338 SCD 05/04/2022 1530 40389 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run bis(2-Ethylhexyl)phthalate 117-81-7 8270D 3.1 J 4.0 0.50 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 2-Fluorobiphenyl 2-Fluorophenol Nitrobenzene-d5 Phenol-d5 Terphenyl-d14 2,4,6-Tribromophenol 69 37-129 44 24-127 83 38-127 59 28-128 85 10-148 51 35-144 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 115 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-032 Description: MW-C Matrix: Aqueous Date Sampled:04/27/2022 1325 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1751 BNW Prep Date Batch 04/30/2022 1125 39935 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 15 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 116 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-033 Description: MW-J Matrix: Aqueous Date Sampled:04/27/2022 1345 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221720 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 117 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-033 Description: MW-J Matrix: Aqueous Date Sampled:04/27/2022 1345 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221720 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 95 70-130 123 70-130 102 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 118 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-033 Description: MW-J Matrix: Aqueous Date Sampled:04/27/2022 1345 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1808 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 15 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 119 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-034 Description: MW-A Matrix: Aqueous Date Sampled:04/27/2022 1420 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/02/2022 1843 TAD 40142 1 (BOD, 5 day) SM 521OB-2011 1 05/04/2022 1246 TAD 04/28/2022 2347 39762 1 (Chloride) 9056A 1 04/29/2022 1141 CAW 40129 1 (CO2 (calcula) SM 4500-CO2 D 1 05/02/2022 1843 TAD 1 (COD) SM 5220D-2011 1 05/03/2022 1442 KKP 40107 1 (Nitrate - N) 9056A 1 04/29/2022 1141 CAW 40135 2 (Nitrate - N) 9056A 5 05/03/2022 1623 CAW 40603 1 (Sulfate) 9056A 1 04/29/2022 1141 CAW 40131 1 (Sulfide) SM 4500-S2 F-2011 1 04/29/2022 1211 SJL 39710 2 (TOC) SM 531OC-2011 1 05/10/2022 1936 DMA 41129 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 160 20 20 mg CaCO3/L 1 BOD, 5 day SM 521OB-2011 ND 2000 180 ug/L 1 Chloride 9056A 20000 1000 250 ug/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 670000 27000 27000 ug/L 1 COD SM 5220D-2011 ND 20000 20000 ug/L 1 Sulfate 9056A 11000 1000 250 ug/L 1 Nitrate - N 9056A ND 20 5.0 ug/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 ND 1000 1000 ug/L 1 Nitrate - N 9056A ND H 100 25 ug/L 2 TOC SM 531OC-2011 1900 1000 1000 ug/L 2 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 120 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-034 Description: MW-A Matrix: Aqueous Date Sampled:04/27/2022 1420 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221746 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 7.0 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.92 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 3.5 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 20 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 9.3 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.42 J 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 79 0.50 0.40 ug/L 1 trans-1,2-Dichloroethene 156-60-5 8260D 0.45 J 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 1.6 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 2.3 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 3.7 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 121 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-034 Description: MW-A Matrix: Aqueous Date Sampled:04/27/2022 1420 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221746 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 2.6 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 0.49 J 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 121 70-130 101 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 122 of 331 Dissolved Gases Client:CDM Smith Laboratory ID:XD27004-034 Description: MW-A Matrix: Aqueous Date Sampled:04/27/2022 1420 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 05/06/2022 1647 JM1 40722 2 RSK - 175 10 05/11/2022 1425 JM1 41253 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 ND 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 ND 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 11000 BE 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 123 of 331 Dissolved Gases Client:CDM Smith Laboratory ID:XD27004-034 Description: MW-A Matrix: Aqueous Date Sampled:04/27/2022 1420 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 05/06/2022 1647 JM1 40722 2 RSK - 175 10 05/11/2022 1425 JM1 41253 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 ND 100 25 ug/L 2 Ethene 74-85-1 RSK - 175 ND 100 25 ug/L 2 Methane 74-82-8 RSK - 175 10000 B 100 25 ug/L 2 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 124 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-034 Description: MW-A Matrix: Aqueous Date Sampled:04/27/2022 1420 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1833 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 47 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 8.2 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 16 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 3.3 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 125 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-035 Description: CD-4 Rep Matrix: Aqueous Date Sampled:04/27/2022 1515 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221811 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 1.4 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 126 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-035 Description: CD-4 Rep Matrix: Aqueous Date Sampled:04/27/2022 1515 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221811 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 95 70-130 121 70-130 100 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 127 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-035 Description: CD-4 Rep Matrix: Aqueous Date Sampled:04/27/2022 1515 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1836 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 74 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.24 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.5 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 9.0 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.65 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.1 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.9 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 4.3 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 128 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-036 Description: TRIP BLANK Matrix: Aqueous Date Sampled:04/27/2022 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221218 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 129 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-036 Description: TRIP BLANK Matrix: Aqueous Date Sampled:04/27/2022 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221218 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 95 70-130 118 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 130 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-036 Description: TRIP BLANK Matrix: Aqueous Date Sampled:04/27/2022 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/11/2022 0121 BBW 41173 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 100 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 131 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-046 Description: CD-2 Matrix: Aqueous Date Sampled:04/27/2022 1530 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/02/2022 1850 TAD 40142 1 (Chloride) 9056A 1 05/24/2022 1147 CAW 42838 1 (Sulfate) 9056A 1 05/24/2022 1147 CAW 42840 1 (TDS) SM 2540C-2015 1 05/04/2022 1823 CVR 40420 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su Chloride Sulfate TDS SM 2320B-2011 87 20 20 mg CaCO3/L 1 9056A 19000 1000 250 ug/L 1 9056A 4100 1000 250 ug/L 1 SM 254OC-2015 150000 25000 25000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 132 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-046 Description: CD-2 Matrix: Aqueous Date Sampled:04/27/2022 1530 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221836 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 1.3 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.77 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 8.8 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 1.6 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 133 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-046 Description: CD-2 Matrix: Aqueous Date Sampled:04/27/2022 1530 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221836 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 123 70-130 Toluene-d8 102 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 134 of 331 CVAA Client:CDM Smith Laboratory ID:XD27004-046 Description: CD-2 Matrix: Aqueous Date Sampled:04/27/2022 1530 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 05/03/2022 0707 JA132 05/03/2022 0301 40151 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND S 0.20 0.091 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 135 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-046 Description: CD-2 Matrix: Aqueous Date Sampled:04/27/2022 1530 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1840 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 90 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.0 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 3.8 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 2.5 J 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 2700 50 13 ug/L 1 Lead 7439-92-1 6020B 0.96 J 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 160 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B 4.0 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 6.1 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 7.3 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 136 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-048 Description: DUP Matrix: Aqueous Date Sampled:04/27/2022 0800 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/05/2022 1815 TAD 40624 1 (Chloride) 9056A 1 05/24/2022 1128 CAW 42838 1 (Sulfate) 9056A 1 05/24/2022 1128 CAW 42840 1 (TDS) SM 2540C-2015 1 05/04/2022 1823 CVR 40420 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su Chloride Sulfate TDS SM 2320B-2011 85 20 20 mg CaCO3/L 1 9056A 18000 1000 250 ug/L 1 9056A 4300 1000 250 ug/L 1 SM 254OC-2015 130000 25000 25000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 137 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-048 Description: DUP Matrix: Aqueous Date Sampled:04/27/2022 0800 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221902 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 1.2 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.66 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 8.6 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 1.5 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 138 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-048 Description: DUP Matrix: Aqueous Date Sampled:04/27/2022 0800 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221902 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 93 70-130 1,2-Dichloroethane-d4 123 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 139 of 331 CVAA Client:CDM Smith Laboratory ID:XD27004-048 Description: DUP Matrix: Aqueous Date Sampled:04/27/2022 0800 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 05/03/2022 0715 JA132 05/03/2022 0301 40151 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.20 0.091 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 140 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-048 Description: DUP Matrix: Aqueous Date Sampled:04/27/2022 0800 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1843 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 86 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 3.7 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 2000 50 13 ug/L 1 Lead 7439-92-1 6020B 0.59 J 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 150 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B 3.7 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.9 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 6.2 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 141 of 331 CVAA Client:CDM Smith Laboratory ID:XD27004-051 Description: CD-1d Matrix: Aqueous Date Sampled:04/27/2022 1605 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 05/03/2022 0718 JA132 05/03/2022 0301 40151 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.20 0.091 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 142 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-051 Description: CD-1d Matrix: Aqueous Date Sampled:04/27/2022 1605 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1847 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 30 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.4 J 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 320 50 13 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 9.2 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.1 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.3 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 143 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-052 Description: CD-7 Matrix: Aqueous Date Sampled:04/25/2022 1020 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/02/2022 1856 TAD 40142 1 (Chloride) 9056A 1 05/23/2022 2117 CAW 42795 1 (Sulfate) 9056A 1 05/23/2022 2117 CAW 42796 1 (TDS) SM 2540C-2015 1 05/07/2022 1333 CVR 40784 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su Chloride Sulfate TDS SM 2320B-2011 250 20 20 mg CaCO3/L 1 9056A 35000 1000 250 ug/L 1 9056A 67000 1000 250 ug/L 1 SM 2540C-2015 460000 H 25000 25000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 144 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-052 Description: CD-7 Matrix: Aqueous Date Sampled:04/25/2022 1020 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221927 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 1.5 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.94 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 1.3 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 3.2 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.58 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 5.0 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.67 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D 3.7 J 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.42 J 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 145 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-052 Description: CD-7 Matrix: Aqueous Date Sampled:04/25/2022 1020 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221927 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D 0.51 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 3.7 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 97 70-130 1,2-Dichloroethane-d4 124 70-130 Toluene-d8 102 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 146 of 331 CVAA Client:CDM Smith Laboratory ID:XD27004-052 Description: CD-7 Matrix: Aqueous Date Sampled:04/25/2022 1020 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 05/03/2022 0720 JAB2 05/03/2022 0301 40151 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.20 0.091 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 147 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-052 Description: CD-7 Matrix: Aqueous Date Sampled:04/25/2022 1020 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method 1 3005A 2 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1850 BNW 6020B 10 05/04/2022 1037 BNW Prep Date Batch 04/30/2022 1206 39937 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 210 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 16 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 6.8 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 250 50 13 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 5400 50 13 ug/L 2 Nickel 7440-02-0 6020B 19 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 7.2 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 148 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-053 Description: TRIP BLANK Matrix: Aqueous Date Sampled:04/27/2022 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221243 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 149 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-053 Description: TRIP BLANK Matrix: Aqueous Date Sampled:04/27/2022 Project Name: Cabarrus County Unit 2 & Date Received:04/28/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/03/20221243 BWS 40237 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 96 70-130 1,2-Dichloroethane-d4 120 70-130 Toluene-d8 101 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 150 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-054 Description: MW-1 Matrix: Aqueous Date Sampled:04/28/2022 0830 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221510 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 1.9 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 0.89 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 151 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-054 Description: MW-1 Matrix: Aqueous Date Sampled:04/28/2022 0830 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221510 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 90 70-130 95 70-130 96 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 152 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-054 Description: MW-1 Matrix: Aqueous Date Sampled:04/28/2022 0830 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/03/2022 1657 KJH 40214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 69 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 98 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 153 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-054 Description: MW-1 Matrix: Aqueous Date Sampled:04/28/2022 0830 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1854 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 140 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 12 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 2.3 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.3 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 29 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 2.7 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 154 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-055 Description: MW-G Matrix: Aqueous Date Sampled:04/28/2022 0845 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221533 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 2.5 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 1.2 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 1.3 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 1.8 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.52 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 155 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-055 Description: MW-G Matrix: Aqueous Date Sampled:04/28/2022 0845 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221533 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.76 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 93 70-130 96 70-130 97 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 156 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-055 Description: MW-G Matrix: Aqueous Date Sampled:04/28/2022 0845 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/03/2022 1722 KJH 40214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 88 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 96 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 157 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-055 Description: MW-G Matrix: Aqueous Date Sampled:04/28/2022 0845 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1857 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 3.3 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 300 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 28 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 35 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.7 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 158 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-056 Description: MW-10 Matrix: Aqueous Date Sampled:04/28/2022 0935 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221556 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 1.0 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 31 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.75 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 4.8 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 159 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-056 Description: MW-10 Matrix: Aqueous Date Sampled:04/28/2022 0935 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221556 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 95 70-130 94 70-130 98 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 160 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-056 Description: MW-10 Matrix: Aqueous Date Sampled:04/28/2022 0935 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/03/2022 1747 KJH 40214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 71 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 95 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 161 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-056 Description: MW-10 Matrix: Aqueous Date Sampled:04/28/2022 0935 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1901 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 41 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 150 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.74 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 6.1 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 27 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 2.1 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.2 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 130 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 2.3 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 6.9 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 8.2 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 162 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-057 Description: MW-5 Matrix: Aqueous Date Sampled:04/28/2022 1025 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221619 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 4.8 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 2.4 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 163 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-057 Description: MW-5 Matrix: Aqueous Date Sampled:04/28/2022 1025 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221619 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 95 70-130 98 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 164 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-057 Description: MW-5 Matrix: Aqueous Date Sampled:04/28/2022 1025 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/03/2022 1811 KJH 40214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 42 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 99 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 165 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-057 Description: MW-5 Matrix: Aqueous Date Sampled:04/28/2022 1025 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1904 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 86 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.19 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.4 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.2 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.2 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.7 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 19 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 7.3 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 11 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 166 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-058 Description: MW-11 Matrix: Aqueous Date Sampled:04/28/2022 1110 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221642 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 167 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-058 Description: MW-11 Matrix: Aqueous Date Sampled:04/28/2022 1110 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221642 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 89 70-130 95 70-130 95 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 168 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-058 Description: MW-11 Matrix: Aqueous Date Sampled:04/28/2022 1110 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/03/2022 1835 KJH 40214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 5.1 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 97 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 169 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-058 Description: MW-11 Matrix: Aqueous Date Sampled:04/28/2022 1110 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1915 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 140 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 8.7 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.7 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 8.6 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 25 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 170 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-059 Description: MW-7 Matrix: Aqueous Date Sampled:04/28/2022 1200 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221706 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 1.1 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 28 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.72 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 8.0 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 171 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-059 Description: MW-7 Matrix: Aqueous Date Sampled:04/28/2022 1200 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221706 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 91 70-130 95 70-130 96 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 172 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-059 Description: MW-7 Matrix: Aqueous Date Sampled:04/28/2022 1200 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/03/2022 1900 KJH 40214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 110 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 97 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 173 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-059 Description: MW-7 Matrix: Aqueous Date Sampled:04/28/2022 1200 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1918 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 8.9 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 810 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 35 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 110 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 29 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.2 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 174 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-060 Description: MW-8a Matrix: Aqueous Date Sampled:04/28/2022 1240 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221729 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 175 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-060 Description: MW-8a Matrix: Aqueous Date Sampled:04/28/2022 1240 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221729 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 95 70-130 96 70-130 98 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 176 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-060 Description: MW-8a Matrix: Aqueous Date Sampled:04/28/2022 1240 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/03/2022 1925 KJH 40214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 96 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 177 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-060 Description: MW-8a Matrix: Aqueous Date Sampled:04/28/2022 1240 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1922 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.51 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 1.3 J 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 58 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.43 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 21 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 29 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 2.6 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 180 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 570 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 178 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-061 Description: DUP Matrix: Aqueous Date Sampled:04/28/2022 0800 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221752 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 179 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-061 Description: DUP Matrix: Aqueous Date Sampled:04/28/2022 0800 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221752 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 98 70-130 98 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 180 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-061 Description: DUP Matrix: Aqueous Date Sampled:04/28/2022 0800 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/03/2022 1949 KJH 40214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 4.2 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 95 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 181 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-061 Description: DUP Matrix: Aqueous Date Sampled:04/28/2022 0800 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1925 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 140 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 9.2 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.4 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 8.2 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 24 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 182 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-062 Description: EQ Blank (Unit 1) Matrix: Aqueous Date Sampled:04/28/2022 1410 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221142 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 183 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-062 Description: EQ Blank (Unit 1) Matrix: Aqueous Date Sampled:04/28/2022 1410 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221142 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 93 70-130 98 70-130 96 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 184 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-062 Description: EQ Blank (Unit 1) Matrix: Aqueous Date Sampled:04/28/2022 1410 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/03/2022 2013 KJH 40214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 95 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 185 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-062 Description: EQ Blank (Unit 1) Matrix: Aqueous Date Sampled:04/28/2022 1410 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1929 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B ND 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 186 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-063 Description: EQ Blank (Unit 2) Matrix: Aqueous Date Sampled:04/28/2022 1400 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221139 BWS 40563 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 187 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-063 Description: EQ Blank (Unit 2) Matrix: Aqueous Date Sampled:04/28/2022 1400 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221139 BWS 40563 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 101 70-130 111 70-130 97 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 188 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-063 Description: EQ Blank (Unit 2) Matrix: Aqueous Date Sampled:04/28/2022 1400 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/03/2022 2037 KJH 40214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 96 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 189 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-063 Description: EQ Blank (Unit 2) Matrix: Aqueous Date Sampled:04/28/2022 1400 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1932 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B ND 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 190 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-064 Description: CD-9 Matrix: Aqueous Date Sampled:04/27/2022 1500 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/02/2022 1904 TAD 40142 1 (Chloride) 9056A 1 05/24/2022 1206 CAW 42838 1 (Sulfate) 9056A 1 05/24/2022 1206 CAW 42840 1 (TDS) SM 2540C-2015 1 05/04/2022 1823 CVR 40420 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su Chloride Sulfate TDS SM 2320B-2011 120 20 20 mg CaCO3/L 1 9056A 5000 1000 250 ug/L 1 9056A 6800 1000 250 ug/L 1 SM 254OC-2015 170000 25000 25000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 191 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-064 Description: CD-9 Matrix: Aqueous Date Sampled:04/27/2022 1500 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221815 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND H 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND H 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND H 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND H 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND H 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND H 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND H 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND H 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND H 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND H 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND H 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND H 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND H 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND H 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND H 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND H 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND H 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND H 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND H 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND H 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.48 HJ 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND H 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D ND H 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 1.7 H 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND H 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND H 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND H 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND H 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND H 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND H 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND H 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND H 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND H 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND H 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND H 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND H 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND H 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND H 0.50 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND H 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND H 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND H 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND H 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND H 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 192 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-064 Description: CD-9 Matrix: Aqueous Date Sampled:04/27/2022 1500 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221815 JWO 40576 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D ND H 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND H 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND H 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND H 1.0 0.40 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene H 91 70-130 1,2-Dichloroethane-d4 H 93 70-130 Toluene-d8 H 95 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 193 of 331 CVAA Client:CDM Smith Laboratory ID:XD27004-064 Description: CD-9 Matrix: Aqueous Date Sampled:04/27/2022 1500 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 05/06/2022 0833 JA132 05/06/2022 0316 40633 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.20 0.091 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 194 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-064 Description: CD-9 Matrix: Aqueous Date Sampled:04/27/2022 1500 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1936 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 76 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 92 50 13 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 4.5 J 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.0 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 195 of 331 Inorganic non-metals Client:CDM Smith Laboratory ID:XD27004-065 Description: EQ Blank Matrix: Aqueous Date Sampled:04/28/2022 1350 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/02/2022 1908 TAD 40142 1 (Chloride) 9056A 1 05/24/2022 1806 CAW 42838 1 (Sulfate) 9056A 1 05/24/2022 1806 CAW 42840 1 (TDS) SM 2540C-2015 1 05/04/2022 1823 CVR 40420 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su Chloride Sulfate TDS SM 2320B-2011 ND 20 20 mg CaCO3/L 1 9056A ND 1000 250 ug/L 1 9056A ND 1000 250 ug/L 1 SM 2540C-2015 ND 25000 25000 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 196 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-065 Description: EQ Blank Matrix: Aqueous Date Sampled:04/28/2022 1350 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221203 BWS 40563 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 197 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-065 Description: EQ Blank Matrix: Aqueous Date Sampled:04/28/2022 1350 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221203 BWS 40563 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 93 70-130 1,2-Dichloroethane-d4 106 70-130 Toluene-d8 93 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 198 of 331 CVAA Client:CDM Smith Laboratory ID:XD27004-065 Description: EQ Blank Matrix: Aqueous Date Sampled:04/28/2022 1350 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 05/06/2022 0835 JA132 05/06/2022 0316 40633 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.20 0.091 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 199 of 331 ICP-MS Metals Client:CDM Smith Laboratory ID:XD27004-065 Description: EQ Blank Matrix: Aqueous Date Sampled:04/28/2022 1350 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 05/03/2022 1939 BNW Prep Date Batch 04/30/2022 1206 39937 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B ND 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B ND 50 13 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B ND 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 200 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-066 Description: Trip Blank Matrix: Aqueous Date Sampled:04/28/2022 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221228 BWS 40563 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D ND 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methacrylonitrile 126-98-7 8260D ND 5.0 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D ND 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 0.50 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 201 of 331 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XD27004-066 Description: Trip Blank Matrix: Aqueous Date Sampled:04/28/2022 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/05/20221228 BWS 40563 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D ND 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 97 70-130 1,2-Dichloroethane-d4 111 70-130 Toluene-d8 98 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 202 of 331 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XD27004-066 Description: Trip Blank Matrix: Aqueous Date Sampled:04/28/2022 Project Name: Cabarrus County Unit 2 & Date Received:04/29/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/11/2022 0146 BBW 41173 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 101 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 203 of 331 QC Summary Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 204 of 331 Inorganic non-metals - BOD Blank and GGA Matrix: Aqueous Batch: 39567 SCF: 0.8 Analytical Method: SM 521 OB-2011 SCF Range: 0.6 - 1.0 Result Avg. Result Sample ID (ug/L) (ug/L) (ug/L) (rng/L) Q Limit Prep Date Analysis Date XQ39567-041 (Blank) 130.0000 0.2 04/27/2022 1800 05/02/2022 1616 XQ39567-141 (Blank) 220.0000 4 0.2 04/27/2022 1800 05/02/2022 1616 XQ39567-241 (Blank) 230.0000190.0000 4 0.2 04/27/2022 1800 05/02/2022 1616 XQ39567-035 (GGA) 189400.0000 167.5-228.5 04/27/2022 1807 05/02/2022 1623 XQ39567-135 (GGA) 199900.0000 167.5-228.5 04/27/2022 1807 05/02/2022 1621 XQ39567-235 (GGA) 192900.00M.1 167.5-228.5 04/27/2022 1807 05/02/2022 1624 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 205 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ39710-001 Matrix: Aqueous Batch: 39710 Analytical Method: SM 4500-S2 F-2011 Parameter Result Q Dil LOQ DL Units Analysis Date Sulfide ND 1 1000 1000 ug/L 04/29/20221211 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 206 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ39710-002 Matrix: Aqueous Batch: 39710 Analytical Method: SM 4500-S2 F-2011 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Sulfide 10000 9300 1 93 80-120 04/29/20221211 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 207 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MS Sample ID: XD27004-002MS Matrix: Aqueous Batch: 39710 Analytical Method: SM 4500-S2 F-2011 Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Sulfide ND 10000 6200 N 1 62 70-130 04/29/20221211 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 208 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MSD Sample ID: XD27004-002MD Matrix: Aqueous Batch: 39710 Analytical Method: SM 4500-S2 F-2011 Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Sulfide ND 10000 7300 1 73 16 70-130 20 04/29/20221211 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 209 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ39723-001 Matrix: Aqueous Batch: 39723 Analytical Method: SM 5220D-2011 Parameter Result Q Dil LOQ DL Units Analysis Date COD ND 1 20000 20000 ug/L 04/29/20221807 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 210 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ39723-002 Matrix: Aqueous Batch: 39723 Analytical Method: SM 5220D-2011 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date COD 40000 41000 1 103 95-105 04/29/20221808 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 211 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MS Sample ID: XD27004-001 MS Matrix: Aqueous Batch: 39723 Analytical Method: SM 5220D-2011 Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date COD ND 40000 36000 N 1 89 90-110 04/29/20221811 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 212 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MSD Sample ID: XD27004-001 MD Matrix: Aqueous Batch: 39723 Analytical Method: SM 5220D-2011 Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date COD ND 40000 33000 N 1 82 8.2 90-110 20 04/29/20221811 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 213 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ39755-002 Matrix: Aqueous Batch: 39755 Analytical Method: SM 2320B-2011 Spike Amount Result %Rec Parameter (mg CaCO3/L) (mg CaCO3/L) Q Dil % Rec Limit Analysis Date Alkalinity @ pH 4.5 su 100 100 1 104 90-110 04/28/2022 1614 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 214 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - Duplicate Sample ID: XD27004-005DU Matrix: Aqueous Batch: 39755 Analytical Method: SM 2320B-2011 Sample Amount Result %RPD Parameter (mg CaCO3/L) (mg CaCO3/L) Q Dil % RPD Limit Analysis Date Alkalinity @ pH 4.5 su 110 110 1 0.91 20 04/28/2022 1704 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 215 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - BOD Blank and GGA Matrix: Aqueous Batch: 39762 SCF: 0.8 Analytical Method: SM 521 OB-2011 SCF Range: 0.6 - 1.0 Result Avg. Result Sample ID (ug/L) (ug/L) (ug/L) (rng/L) Q Limit Prep Date Analysis Date XQ39762-041 (Blank) 70.0000 0.2 04/28/2022 2226 05/03/2022 2348 XQ39762-141 (Blank) -40.0000 0.2 04/28/2022 2226 05/03/2022 2348 XQ39762-241 (Blank) 0.0000 10.0000 0.2 04/28/2022 2226 05/03/2022 2348 XQ39762-035 (GGA) 227500.0000 167.5-228.5 04/28/2022 2233 05/03/2022 2354 XQ39762-135 (GGA) 189500.0000 167.5-228.5 04/28/2022 2233 05/03/2022 2353 XQ39762-235 (GGA) 198500.00M.2 167.5-228.5 04/28/2022 2233 05/03/2022 2353 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 216 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ39853-001 Matrix: Aqueous Batch: 39853 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate ND 1 1000 250 ug/L 04/28/20221123 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 217 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ39853-002 Matrix: Aqueous Batch: 39853 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Sulfate 20000 21000 1 104 80-120 04/28/20221201 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 218 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ39868-001 Matrix: Aqueous Batch: 39868 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Chloride ND 1 1000 250 ug/L 04/28/20221123 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 219 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ39868-002 Matrix: Aqueous Batch: 39868 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Chloride 20000 20000 1 102 80-120 04/28/20221201 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 220 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ39879-001 Matrix: Aqueous Batch: 39879 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N 11 J 1 20 5.0 ug/L 04/28/2022 1123 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 221 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ39879-002 Matrix: Aqueous Batch: 39879 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Nitrate - N 800 870 1 109 80-120 04/28/2022 1201 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 222 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40107-001 Matrix: Aqueous Batch: 40107 Analytical Method: SM 5220D-2011 Parameter Result Q Dil LOQ DL Units Analysis Date COD ND 1 20000 20000 ug/L 05/03/20221438 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 223 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40107-002 Matrix: Aqueous Batch: 40107 Analytical Method: SM 5220D-2011 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date COD 40000 40000 1 101 95-105 05/03/20221439 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 224 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40129-001 Matrix: Aqueous Batch: 40129 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Chloride ND 1 1000 250 ug/L 04/29/20221020 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 225 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40129-002 Matrix: Aqueous Batch: 40129 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Chloride 20000 21000 1 103 80-120 04/29/20221058 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 226 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40131-001 Matrix: Aqueous Batch: 40131 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate ND 1 1000 250 ug/L 04/29/20221020 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 227 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40131-002 Matrix: Aqueous Batch: 40131 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Sulfate 20000 22000 1 108 80-120 04/29/20221058 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 228 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40132-001 Matrix: Aqueous Batch: 40132 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate ND 1 1000 250 ug/L 04/29/20221856 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 229 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40132-002 Matrix: Aqueous Batch: 40132 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Sulfate 20000 20000 1 102 80-120 04/29/2022 2031 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 230 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40135-001 Matrix: Aqueous Batch: 40135 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N ND 1 20 5.0 ug/L 04/29/2022 1020 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 231 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40135-002 Matrix: Aqueous Batch: 40135 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Nitrate - N 800 860 1 108 80-120 04/29/2022 1058 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 232 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40136-001 Matrix: Aqueous Batch: 40136 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N 5.9 J 1 20 5.0 ug/L 04/29/2022 1856 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 233 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40136-002 Matrix: Aqueous Batch: 40136 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Nitrate - N 800 880 1 109 80-120 04/29/2022 2031 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 234 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40142-002 Matrix: Aqueous Batch: 40142 Analytical Method: SM 2320B-2011 Spike Amount Result %Rec Parameter (mg CaCO3/L) (mg CaCO3/L) Q Dil % Rec Limit Analysis Date Alkalinity @ pH 4.5 su 100 110 1 107 90-110 05/02/2022 1712 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 235 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40227-001 Matrix: Aqueous Batch:40227 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N 5.9 J 1 20 5.0 ug/L 05/02/2022 2054 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 236 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40227-002 Matrix: Aqueous Batch:40227 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Nitrate - N 800 870 1 109 80-120 05/02/2022 2228 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 237 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MS Sample ID: XD27004-001 MS Matrix: Aqueous Batch:40227 Analytical Method: 9056A Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Nitrate - N 88 400 82 N 1 -1.6 80-120 05/03/2022 0234 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 238 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MSD Sample ID: XD27004-001 MD Matrix: Aqueous Batch:40227 Analytical Method: 9056A Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Nitrate - N 88 400 78 N 1 -2.5 4.1 80-120 20 05/03/2022 0253 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 239 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40264-001 Matrix: Aqueous Batch:40264 Analytical Method: SM 2540C-2015 Parameter Result Q Dil LOQ DL Units Analysis Date TDS ND 1 25000 25000 ug/L 05/03/20221738 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 240 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40264-002 Matrix: Aqueous Batch:40264 Analytical Method: SM 2540C-2015 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date TDS 50000 53000 1 106 90-110 05/03/20221738 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 241 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40420-001 Matrix: Aqueous Batch:40420 Analytical Method: SM 2540C-2015 Parameter Result Q Dil LOQ DL Units Analysis Date TDS ND 1 25000 25000 ug/L 05/04/20221823 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 242 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40420-002 Matrix: Aqueous Batch:40420 Analytical Method: SM 2540C-2015 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date TDS 50000 55000 1 110 90-110 05/04/20221823 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 243 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40603-001 Matrix: Aqueous Batch:40603 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N ND 1 20 5.0 ug/L 05/03/2022 1334 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 244 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40603-002 Matrix: Aqueous Batch:40603 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Nitrate - N 800 870 1 109 80-120 05/03/2022 1412 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 245 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCSD Sample ID: XQ40603-003 Matrix: Aqueous Batch:40603 Analytical Method: 9056A Spike Amount Result %Rec % RPD Parameter (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Nitrate - N 800 870 1 109 0.023 80-120 20 05/04/2022 0035 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 246 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40624-002 Matrix: Aqueous Batch:40624 Analytical Method: SM 2320B-2011 Spike Amount Result %Rec Parameter (mg CaCO3/L) (mg CaCO3/L) Q Dil % Rec Limit Analysis Date Alkalinity @ pH 4.5 su 100 110 1 106 90-110 05/05/2022 1810 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 247 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40686-001 Matrix: Aqueous Batch:40686 Analytical Method: SM 531 OC-2011 Parameter Result Q Dil LOQ DL Units Analysis Date TOC ND 1 1000 1000 ug/L 05/06/20221709 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 248 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40686-002 Matrix: Aqueous Batch:40686 Analytical Method: SM 531 OC-2011 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date TOC 20000 19000 1 94 90-110 05/06/20221722 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 249 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MS Sample ID: XD27004-003MS Matrix: Aqueous Batch:40686 Analytical Method: SM 531 OC-2011 Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date TOC 2800 50000 47000 1 89 70-130 05/06/2022 2228 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 250 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MSD Sample ID: XD27004-003MD Matrix: Aqueous Batch:40686 Analytical Method: SM 531 OC-2011 Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date TOC 2800 50000 47000 1 88 0.58 70-130 20 05/06/2022 2241 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 251 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40784-001 Matrix: Aqueous Batch:40784 Analytical Method: SM 2540C-2015 Parameter Result Q Dil LOQ DL Units Analysis Date TDS ND 1 25000 25000 ug/L 05/07/20221333 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 252 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40784-002 Matrix: Aqueous Batch:40784 Analytical Method: SM 2540C-2015 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date TDS 50000 46000 1 92 90-110 05/07/20221333 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 253 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ40969-001 Matrix: Aqueous Batch: 40969 Analytical Method: SM 531 OC-2011 Parameter Result Q Dil LOQ DL Units Analysis Date TOC ND 1 1000 1000 ug/L 05/10/2022 2022 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 254 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ40969-002 Matrix: Aqueous Batch: 40969 Analytical Method: SM 531 OC-2011 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date TOC 20000 19000 1 93 90-110 05/10/2022 2034 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 255 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ41129-001 Matrix: Aqueous Batch: 41129 Analytical Method: SM 531 OC-2011 Parameter Result Q Dil LOQ DL Units Analysis Date TOC ND 1 1000 1000 ug/L 05/10/20221910 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 256 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ41129-002 Matrix: Aqueous Batch: 41129 Analytical Method: SM 531 OC-2011 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date TOC 20000 20000 1 99 90-110 05/10/20221923 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 257 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ42795-001 Matrix: Aqueous Batch: 42795 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Chloride ND 1 1000 250 ug/L 05/23/2022 0900 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 258 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ42795-002 Matrix: Aqueous Batch: 42795 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Chloride 20000 20000 1 98 80-120 05/23/2022 0937 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 259 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ42796-001 Matrix: Aqueous Batch: 42796 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate ND 1 1000 250 ug/L 05/23/2022 0900 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 260 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ42796-002 Matrix: Aqueous Batch: 42796 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Sulfate 20000 20000 1 99 80-120 05/23/2022 0937 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 261 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ42838-001 Matrix: Aqueous Batch:42838 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Chloride ND 1 1000 250 ug/L 05/24/2022 0925 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 262 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ42838-002 Matrix: Aqueous Batch:42838 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Chloride 20000 21000 1 103 80-120 05/24/20221003 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 263 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - MB Sample ID: XQ42840-001 Matrix: Aqueous Batch:42840 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate ND 1 1000 250 ug/L 05/24/2022 0925 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 264 of 331 QC Data for Lot Number: XD27004 Inorganic non-metals - LCS Sample ID: XQ42840-002 Matrix: Aqueous Batch:42840 Analytical Method: 9056A Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Sulfate 20000 20000 1 102 80-120 05/24/20221003 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 265 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: XQ39871-001 Matrix: Aqueous Batch:39871 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane ND 1 3.0 1.0 ug/L 04/29/20221048 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 95 40-170 ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 266 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: XQ39871-002 Matrix: Aqueous Batch:39871 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 41 1 83 70-130 04/29/2022 0946 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 98 40-170 ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 267 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ40083-001 Matrix: Aqueous Batch:40083 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 10 4.0 ug/L 05/02/2022 1029 Acrylonitrile ND 1 5.0 0.80 ug/L 05/02/2022 1029 Benzene ND 1 0.50 0.40 ug/L 05/02/2022 1029 Bromochloromethane ND 1 0.50 0.40 ug/L 05/02/2022 1029 Bromodichloromethane ND 1 0.50 0.40 ug/L 05/02/2022 1029 Bromoform ND 1 0.50 0.40 ug/L 05/02/2022 1029 Bromomethane (Methyl bromide) ND 1 0.50 0.40 ug/L 05/02/2022 1029 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/02/2022 1029 Carbon disulfide ND 1 0.50 0.40 ug/L 05/02/2022 1029 Carbon tetrachloride ND 1 0.50 0.40 ug/L 05/02/2022 1029 Chlorobenzene ND 1 0.50 0.40 ug/L 05/02/2022 1029 Chloroethane ND 1 0.50 0.40 ug/L 05/02/2022 1029 Chloroform ND 1 0.50 0.40 ug/L 05/02/2022 1029 Chloromethane (Methyl chloride) ND 1 0.50 0.40 ug/L 05/02/2022 1029 1,2-Dibromo-3-chloropropane (DBCP) ND 1 0.50 0.40 ug/L 05/02/2022 1029 Dibromochloromethane ND 1 0.50 0.40 ug/L 05/02/2022 1029 1,2-Dibromoethane (EDB) ND 1 0.50 0.40 ug/L 05/02/2022 1029 Dibromomethane (Methylene bromide) ND 1 0.50 0.40 ug/L 05/02/2022 1029 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.40 ug/L 05/02/2022 1029 1,2-Dichlorobenzene ND 1 0.50 0.40 ug/L 05/02/2022 1029 1,4-Dichlorobenzene ND 1 0.50 0.40 ug/L 05/02/2022 1029 1,1-Dichloroethane ND 1 0.50 0.40 ug/L 05/02/2022 1029 1,2-Dichloroethane ND 1 0.50 0.40 ug/L 05/02/2022 1029 1,1-Dichloroethene ND 1 0.50 0.40 ug/L 05/02/2022 1029 cis- 1,2-Dichloroethene ND 1 0.50 0.40 ug/L 05/02/2022 1029 trans- 1,2-Dichloroethene ND 1 0.50 0.40 ug/L 05/02/2022 1029 1,2-Dichloropropane ND 1 0.50 0.40 ug/L 05/02/2022 1029 cis- 1,3-Dichloropropene ND 1 0.50 0.40 ug/L 05/02/2022 1029 trans- 1,3-Dichloropropene ND 1 0.50 0.40 ug/L 05/02/2022 1029 Ethylbenzene ND 1 0.50 0.40 ug/L 05/02/2022 1029 2-Hexanone ND 1 10 2.0 ug/L 05/02/2022 1029 Methacrylonitrile ND 1 5.0 2.0 ug/L 05/02/2022 1029 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/02/2022 1029 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/02/2022 1029 Methylene chloride ND 1 0.50 0.40 ug/L 05/02/2022 1029 Styrene ND 1 0.50 0.41 ug/L 05/02/2022 1029 1,1,1,2-Tetrachloroethane ND 1 0.50 0.40 ug/L 05/02/2022 1029 1,1,2,2-Tetrachloroethane ND 1 0.50 0.40 ug/L 05/02/2022 1029 Tetrachloroethene ND 1 0.50 0.40 ug/L 05/02/2022 1029 Toluene ND 1 0.50 0.40 ug/L 05/02/2022 1029 1,1,1-Trichloroethane ND 1 0.50 0.40 ug/L 05/02/2022 1029 1,1,2-Trichloroethane ND 1 0.50 0.40 ug/L 05/02/2022 1029 Trichloroethene ND 1 0.50 0.40 ug/L 05/02/2022 1029 Trichlorofluoromethane ND 1 0.50 0.40 ug/L 05/02/2022 1029 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 268 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ40083-001 Matrix: Aqueous Batch:40083 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 1,2,3-Trichloropropane ND 1 0.50 0.40 ug/L 05/02/2022 1029 Vinyl acetate ND 1 5.0 1.2 ug/L 05/02/2022 1029 Vinyl chloride ND 1 0.50 0.40 ug/L 05/02/2022 1029 Xylenes (total) ND 1 1.0 0.40 ug/L 05/02/2022 1029 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 101 70-130 1,2-Dichloroethane-d4 116 70-130 Toluene-d8 106 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 269 of 331 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ40083-002 Matrix: Aqueous Batch:40083 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 88 1 88 60-140 05/02/2022 0922 Acrylonitrile 100 80 1 80 70-130 05/02/2022 0922 Benzene 50 46 1 92 70-130 05/02/2022 0922 Bromochloromethane 50 44 1 88 70-130 05/02/2022 0922 Bromodichloromethane 50 47 1 94 70-130 05/02/2022 0922 Bromoform 50 48 1 96 70-130 05/02/2022 0922 Bromomethane (Methyl bromide) 50 49 1 98 70-130 05/02/2022 0922 2-Butanone (MEK) 100 75 1 75 70-130 05/02/2022 0922 Carbon disulfide 50 45 1 89 70-130 05/02/2022 0922 Carbon tetrachloride 50 45 1 89 70-130 05/02/2022 0922 Chlorobenzene 50 45 1 90 70-130 05/02/2022 0922 Chloroethane 50 42 1 85 70-130 05/02/2022 0922 Chloroform 50 44 1 87 70-130 05/02/2022 0922 Chloromethane (Methyl chloride) 50 43 1 85 60-140 05/02/2022 0922 1,2-Dibromo-3-chloropropane (DBCP) 50 43 1 87 70-130 05/02/2022 0922 Dibromochloromethane 50 49 1 99 70-130 05/02/2022 0922 1,2-Dibromoethane (EDB) 50 47 1 93 70-130 05/02/2022 0922 Dibromomethane (Methylene bromide) 50 43 1 87 70-130 05/02/2022 0922 trans- 1,4-Dichloro-2-butene 50 50 1 101 70-130 05/02/2022 0922 1,2-Dichlorobenzene 50 47 1 95 70-130 05/02/2022 0922 1,4-Dichlorobenzene 50 48 1 96 70-130 05/02/2022 0922 1,1-Dichloroethane 50 46 1 91 70-130 05/02/2022 0922 1,2-Dichloroethane 50 44 1 88 70-130 05/02/2022 0922 1,1-Dichloroethene 50 45 1 89 70-130 05/02/2022 0922 cis- 1,2-Dichloroethene 50 44 1 87 70-130 05/02/2022 0922 trans- 1,2-Dichloroethene 50 44 1 87 70-130 05/02/2022 0922 1,2-Dichloropropane 50 47 1 95 70-130 05/02/2022 0922 cis- 1,3-Dichloropropene 50 46 1 92 70-130 05/02/2022 0922 trans- 1,3-Dichloropropene 50 49 1 98 70-130 05/02/2022 0922 Ethylbenzene 50 48 1 97 70-130 05/02/2022 0922 2-Hexanone 100 91 1 91 70-130 05/02/2022 0922 Methacrylonitrile 250 220 1 86 70-130 05/02/2022 0922 Methyl iodide (lodomethane) 50 44 1 88 70-130 05/02/2022 0922 4-Methyl-2-pentanone 100 86 1 86 70-130 05/02/2022 0922 Methylene chloride 50 46 1 91 70-130 05/02/2022 0922 Styrene 50 47 1 94 70-130 05/02/2022 0922 1,1,1,2-Tetrachloroethane 50 48 1 97 70-130 05/02/2022 0922 1,1,2,2-Tetrachloroethane 50 47 1 94 70-130 05/02/2022 0922 Tetrachloroethene 50 46 1 92 70-130 05/02/2022 0922 Toluene 50 50 1 99 70-130 05/02/2022 0922 1,1,1-Trichloroethane 50 46 1 92 70-130 05/02/2022 0922 1,1,2-Trichloroethane 50 46 1 91 70-130 05/02/2022 0922 Trichloroethene 50 41 1 83 70-130 05/02/2022 0922 Trichlorofluoromethane 50 41 1 83 70-130 05/02/2022 0922 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 270 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ40083-002 Matrix: Aqueous Batch:40083 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,2,3-Trichloropropane 50 46 1 91 70-130 05/02/2022 0922 Vinyl acetate 50 49 1 98 60-140 05/02/2022 0922 Vinyl chloride 50 43 1 87 70-130 05/02/2022 0922 Xylenes (total) 100 100 1 100 70-130 05/02/2022 0922 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 104 70-130 Toluene-d8 100 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 271 of 331 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: XQ40214-001 Matrix: Aqueous Batch:40214 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane ND 1 3.0 1.0 ug/L 05/03/20221207 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 98 40-170 ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 272 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: XQ40214-002 Matrix: Aqueous Batch:40214 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 47 1 94 70-130 05/03/2022 0934 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 108 40-170 ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 273 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ40225-001 Matrix: Aqueous Batch:40225 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 10 4.0 ug/L 05/03/2022 1126 Acrylonitrile ND 1 5.0 0.80 ug/L 05/03/2022 1126 Benzene ND 1 0.50 0.40 ug/L 05/03/2022 1126 Bromochloromethane ND 1 0.50 0.40 ug/L 05/03/2022 1126 Bromodichloromethane ND 1 0.50 0.40 ug/L 05/03/2022 1126 Bromoform ND 1 0.50 0.40 ug/L 05/03/2022 1126 Bromomethane (Methyl bromide) ND 1 0.50 0.40 ug/L 05/03/2022 1126 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/03/2022 1126 Carbon disulfide ND 1 0.50 0.40 ug/L 05/03/2022 1126 Carbon tetrachloride ND 1 0.50 0.40 ug/L 05/03/2022 1126 Chlorobenzene ND 1 0.50 0.40 ug/L 05/03/2022 1126 Chloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1126 Chloroform ND 1 0.50 0.40 ug/L 05/03/2022 1126 Chloromethane (Methyl chloride) ND 1 0.50 0.40 ug/L 05/03/2022 1126 1,2-Dibromo-3-chloropropane (DBCP) ND 1 0.50 0.40 ug/L 05/03/2022 1126 Dibromochloromethane ND 1 0.50 0.40 ug/L 05/03/2022 1126 1,2-Dibromoethane (EDB) ND 1 0.50 0.40 ug/L 05/03/2022 1126 Dibromomethane (Methylene bromide) ND 1 0.50 0.40 ug/L 05/03/2022 1126 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.40 ug/L 05/03/2022 1126 1,2-Dichlorobenzene ND 1 0.50 0.40 ug/L 05/03/2022 1126 1,4-Dichlorobenzene ND 1 0.50 0.40 ug/L 05/03/2022 1126 1,1-Dichloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1126 1,2-Dichloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1126 1,1-Dichloroethene ND 1 0.50 0.40 ug/L 05/03/2022 1126 cis- 1,2-Dichloroethene ND 1 0.50 0.40 ug/L 05/03/2022 1126 trans- 1,2-Dichloroethene ND 1 0.50 0.40 ug/L 05/03/2022 1126 1,2-Dichloropropane ND 1 0.50 0.40 ug/L 05/03/2022 1126 cis- 1,3-Dichloropropene ND 1 0.50 0.40 ug/L 05/03/2022 1126 trans- 1,3-Dichloropropene ND 1 0.50 0.40 ug/L 05/03/2022 1126 Ethylbenzene ND 1 0.50 0.40 ug/L 05/03/2022 1126 2-Hexanone ND 1 10 2.0 ug/L 05/03/2022 1126 Methacrylonitrile ND 1 5.0 2.0 ug/L 05/03/2022 1126 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/03/2022 1126 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/03/2022 1126 Methylene chloride ND 1 0.50 0.40 ug/L 05/03/2022 1126 Styrene ND 1 0.50 0.41 ug/L 05/03/2022 1126 1,1,1,2-Tetrachloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1126 1,1,2,2-Tetrachloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1126 Tetrachloroethene ND 1 0.50 0.40 ug/L 05/03/2022 1126 Tetrahydrofuran ND 1 5.0 1.0 ug/L 05/03/2022 1126 Toluene ND 1 0.50 0.40 ug/L 05/03/2022 1126 1,1,1-Trichloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1126 1,1,2-Trichloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1126 Trichloroethene ND 1 0.50 0.40 ug/L 05/03/2022 1126 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 274 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ40225-001 Matrix: Aqueous Batch:40225 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Trichlorofluoromethane ND 1 0.50 0.40 ug/L 05/03/2022 1126 1,2,3-Trichloropropane ND 1 0.50 0.40 ug/L 05/03/2022 1126 Vinyl acetate ND 1 5.0 1.2 ug/L 05/03/2022 1126 Vinyl chloride ND 1 0.50 0.40 ug/L 05/03/2022 1126 Xylenes (total) ND 1 1.0 0.40 ug/L 05/03/2022 1126 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 93 70-130 1,2-Dichloroethane-d4 96 70-130 Toluene-d8 98 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 275 of 331 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ40225-002 Matrix: Aqueous Batch:40225 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 120 1 117 60-140 05/03/2022 0852 Acrylonitrile 100 100 1 103 70-130 05/03/2022 0852 Benzene 50 46 1 91 70-130 05/03/2022 0852 Bromochloromethane 50 48 1 95 70-130 05/03/2022 0852 Bromodichloromethane 50 46 1 93 70-130 05/03/2022 0852 Bromoform 50 49 1 98 70-130 05/03/2022 0852 Bromomethane (Methyl bromide) 50 47 1 95 70-130 05/03/2022 0852 2-Butanone (MEK) 100 94 1 94 70-130 05/03/2022 0852 Carbon disulfide 50 46 1 92 70-130 05/03/2022 0852 Carbon tetrachloride 50 45 1 90 70-130 05/03/2022 0852 Chlorobenzene 50 46 1 92 70-130 05/03/2022 0852 Chloroethane 50 46 1 93 70-130 05/03/2022 0852 Chloroform 50 46 1 92 70-130 05/03/2022 0852 Chloromethane (Methyl chloride) 50 45 1 91 60-140 05/03/2022 0852 1,2-Dibromo-3-chloropropane (DBCP) 50 49 1 98 70-130 05/03/2022 0852 Dibromochloromethane 50 48 1 96 70-130 05/03/2022 0852 1,2-Dibromoethane (EDB) 50 48 1 96 70-130 05/03/2022 0852 Dibromomethane (Methylene bromide) 50 47 1 95 70-130 05/03/2022 0852 trans- 1,4-Dichloro-2-butene 50 51 1 103 70-130 05/03/2022 0852 1,2-Dichlorobenzene 50 48 1 97 70-130 05/03/2022 0852 1,4-Dichlorobenzene 50 46 1 92 70-130 05/03/2022 0852 1,1-Dichloroethane 50 46 1 92 70-130 05/03/2022 0852 1,2-Dichloroethane 50 45 1 90 70-130 05/03/2022 0852 1,1-Dichloroethene 50 47 1 93 70-130 05/03/2022 0852 cis- 1,2-Dichloroethene 50 47 1 94 70-130 05/03/2022 0852 trans- 1,2-Dichloroethene 50 46 1 93 70-130 05/03/2022 0852 1,2-Dichloropropane 50 46 1 92 70-130 05/03/2022 0852 cis- 1,3-Dichloropropene 50 51 1 101 70-130 05/03/2022 0852 trans- 1,3-Dichloropropene 50 50 1 101 70-130 05/03/2022 0852 Ethylbenzene 50 48 1 97 70-130 05/03/2022 0852 2-Hexanone 100 95 1 95 70-130 05/03/2022 0852 Methacrylonitrile 250 250 1 98 70-130 05/03/2022 0852 Methyl iodide (lodomethane) 50 46 1 92 70-130 05/03/2022 0852 4-Methyl-2-pentanone 100 99 1 99 70-130 05/03/2022 0852 Methylene chloride 50 44 1 87 70-130 05/03/2022 0852 Styrene 50 51 1 102 70-130 05/03/2022 0852 1,1,1,2-Tetrachloroethane 50 47 1 95 70-130 05/03/2022 0852 1,1,2,2-Tetrachloroethane 50 46 1 92 70-130 05/03/2022 0852 Tetrachloroethene 50 48 1 95 70-130 05/03/2022 0852 Tetrahydrofuran 50 51 1 102 70-130 05/03/2022 0852 Toluene 50 47 1 95 70-130 05/03/2022 0852 1,1,1-Trichloroethane 50 46 1 92 70-130 05/03/2022 0852 1,1,2-Trichloroethane 50 46 1 91 70-130 05/03/2022 0852 Trichloroethene 50 47 1 95 70-130 05/03/2022 0852 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 276 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ40225-002 Matrix: Aqueous Batch:40225 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Trichlorofluoromethane 50 47 1 94 70-130 05/03/2022 0852 1,2,3-Trichloropropane 50 47 1 94 70-130 05/03/2022 0852 Vinyl acetate 50 49 1 98 60-140 05/03/2022 0852 Vinyl chloride 50 46 1 92 70-130 05/03/2022 0852 Xylenes (total) 100 97 1 97 70-130 05/03/2022 0852 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 89 70-130 1,2-Dichloroethane-d4 87 70-130 Toluene-d8 93 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 277 of 331 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ40237-001 Matrix: Aqueous Batch:40237 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 10 4.0 ug/L 05/03/2022 1030 Acrylonitrile ND 1 5.0 0.80 ug/L 05/03/2022 1030 Benzene ND 1 0.50 0.40 ug/L 05/03/2022 1030 Bromochloromethane ND 1 0.50 0.40 ug/L 05/03/2022 1030 Bromodichloromethane ND 1 0.50 0.40 ug/L 05/03/2022 1030 Bromoform ND 1 0.50 0.40 ug/L 05/03/2022 1030 Bromomethane (Methyl bromide) ND 1 0.50 0.40 ug/L 05/03/2022 1030 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/03/2022 1030 Carbon disulfide ND 1 0.50 0.40 ug/L 05/03/2022 1030 Carbon tetrachloride ND 1 0.50 0.40 ug/L 05/03/2022 1030 Chlorobenzene ND 1 0.50 0.40 ug/L 05/03/2022 1030 Chloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1030 Chloroform ND 1 0.50 0.40 ug/L 05/03/2022 1030 Chloromethane (Methyl chloride) ND 1 0.50 0.40 ug/L 05/03/2022 1030 1,2-Dibromo-3-chloropropane (DBCP) ND 1 0.50 0.40 ug/L 05/03/2022 1030 Dibromochloromethane ND 1 0.50 0.40 ug/L 05/03/2022 1030 1,2-Dibromoethane (EDB) ND 1 0.50 0.40 ug/L 05/03/2022 1030 Dibromomethane (Methylene bromide) ND 1 0.50 0.40 ug/L 05/03/2022 1030 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.40 ug/L 05/03/2022 1030 1,2-Dichlorobenzene ND 1 0.50 0.40 ug/L 05/03/2022 1030 1,4-Dichlorobenzene ND 1 0.50 0.40 ug/L 05/03/2022 1030 1,1-Dichloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1030 1,2-Dichloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1030 1,1-Dichloroethene ND 1 0.50 0.40 ug/L 05/03/2022 1030 cis- 1,2-Dichloroethene ND 1 0.50 0.40 ug/L 05/03/2022 1030 trans- 1,2-Dichloroethene ND 1 0.50 0.40 ug/L 05/03/2022 1030 1,2-Dichloropropane ND 1 0.50 0.40 ug/L 05/03/2022 1030 cis- 1,3-Dichloropropene ND 1 0.50 0.40 ug/L 05/03/2022 1030 trans- 1,3-Dichloropropene ND 1 0.50 0.40 ug/L 05/03/2022 1030 Ethylbenzene ND 1 0.50 0.40 ug/L 05/03/2022 1030 2-Hexanone ND 1 10 2.0 ug/L 05/03/2022 1030 Methacrylonitrile ND 1 5.0 2.0 ug/L 05/03/2022 1030 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/03/2022 1030 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/03/2022 1030 Methylene chloride ND 1 0.50 0.40 ug/L 05/03/2022 1030 Styrene ND 1 0.50 0.41 ug/L 05/03/2022 1030 1,1,1,2-Tetrachloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1030 1,1,2,2-Tetrachloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1030 Tetrachloroethene ND 1 0.50 0.40 ug/L 05/03/2022 1030 Tetrahydrofuran ND 1 5.0 1.0 ug/L 05/03/2022 1030 Toluene ND 1 0.50 0.40 ug/L 05/03/2022 1030 1,1,1-Trichloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1030 1,1,2-Trichloroethane ND 1 0.50 0.40 ug/L 05/03/2022 1030 Trichloroethene ND 1 0.50 0.40 ug/L 05/03/2022 1030 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 278 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ40237-001 Matrix: Aqueous Batch:40237 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Trichlorofluoromethane ND 1 0.50 0.40 ug/L 05/03/2022 1030 1,2,3-Trichloropropane ND 1 0.50 0.40 ug/L 05/03/2022 1030 Vinyl acetate ND 1 5.0 1.2 ug/L 05/03/2022 1030 Vinyl chloride ND 1 0.50 0.40 ug/L 05/03/2022 1030 Xylenes (total) ND 1 1.0 0.40 ug/L 05/03/2022 1030 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 91 70-130 1,2-Dichloroethane-d4 118 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 279 of 331 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ40237-002 Matrix: Aqueous Batch:40237 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 130 1 132 60-140 05/03/2022 0939 Acrylonitrile 100 94 1 94 70-130 05/03/2022 0939 Benzene 50 52 1 104 70-130 05/03/2022 0939 Bromochloromethane 50 50 1 100 70-130 05/03/2022 0939 Bromodichloromethane 50 54 1 109 70-130 05/03/2022 0939 Bromoform 50 58 1 115 70-130 05/03/2022 0939 Bromomethane (Methyl bromide) 50 61 1 121 70-130 05/03/2022 0939 2-Butanone (MEK) 100 110 1 113 70-130 05/03/2022 0939 Carbon disulfide 50 47 1 93 70-130 05/03/2022 0939 Carbon tetrachloride 50 52 1 103 70-130 05/03/2022 0939 Chlorobenzene 50 53 1 105 70-130 05/03/2022 0939 Chloroethane 50 49 1 98 70-130 05/03/2022 0939 Chloroform 50 50 1 100 70-130 05/03/2022 0939 Chloromethane (Methyl chloride) 50 50 1 100 60-140 05/03/2022 0939 1,2-Dibromo-3-chloropropane (DBCP) 50 55 1 110 70-130 05/03/2022 0939 Dibromochloromethane 50 58 1 116 70-130 05/03/2022 0939 1,2-Dibromoethane (EDB) 50 57 1 113 70-130 05/03/2022 0939 Dibromomethane (Methylene bromide) 50 52 1 103 70-130 05/03/2022 0939 trans- 1,4-Dichloro-2-butene 50 56 1 113 70-130 05/03/2022 0939 1,2-Dichlorobenzene 50 52 1 104 70-130 05/03/2022 0939 1,4-Dichlorobenzene 50 54 1 108 70-130 05/03/2022 0939 1,1-Dichloroethane 50 51 1 102 70-130 05/03/2022 0939 1,2-Dichloroethane 50 52 1 104 70-130 05/03/2022 0939 1,1-Dichloroethene 50 48 1 96 70-130 05/03/2022 0939 cis- 1,2-Dichloroethene 50 50 1 100 70-130 05/03/2022 0939 trans- 1,2-Dichloroethene 50 49 1 97 70-130 05/03/2022 0939 1,2-Dichloropropane 50 55 1 110 70-130 05/03/2022 0939 cis- 1,3-Dichloropropene 50 54 1 107 70-130 05/03/2022 0939 trans- 1,3-Dichloropropene 50 56 1 113 70-130 05/03/2022 0939 Ethylbenzene 50 56 1 113 70-130 05/03/2022 0939 2-Hexanone 100 140 N 1 138 70-130 05/03/2022 0939 Methacrylonitrile 250 300 1 119 70-130 05/03/2022 0939 Methyl iodide (lodomethane) 50 47 1 94 70-130 05/03/2022 0939 4-Methyl-2-pentanone 100 120 1 119 70-130 05/03/2022 0939 Methylene chloride 50 51 1 102 70-130 05/03/2022 0939 Styrene 50 55 1 111 70-130 05/03/2022 0939 1,1,1,2-Tetrachloroethane 50 56 1 112 70-130 05/03/2022 0939 1,1,2,2-Tetrachloroethane 50 56 1 112 70-130 05/03/2022 0939 Tetrachloroethene 50 53 1 107 70-130 05/03/2022 0939 Tetrahydrofuran 50 55 1 110 70-130 05/03/2022 0939 Toluene 50 57 1 114 70-130 05/03/2022 0939 1,1,1-Trichloroethane 50 53 1 107 70-130 05/03/2022 0939 1,1,2-Trichloroethane 50 55 1 110 70-130 05/03/2022 0939 Trichloroethene 50 47 1 94 70-130 05/03/2022 0939 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 280 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ40237-002 Matrix: Aqueous Batch:40237 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Trichlorofluoromethane 50 51 1 102 70-130 05/03/2022 0939 1,2,3-Trichloropropane 50 58 1 117 70-130 05/03/2022 0939 Vinyl acetate 50 58 1 116 60-140 05/03/2022 0939 Vinyl chloride 50 51 1 103 70-130 05/03/2022 0939 Xylenes (total) 100 120 1 116 70-130 05/03/2022 0939 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 113 70-130 1,2-Dichloroethane-d4 111 70-130 Toluene-d8 111 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 281 of 331 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ40563-001 Matrix: Aqueous Batch:40563 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 10 4.0 ug/L 05/05/2022 1042 Acrylonitrile ND 1 5.0 0.80 ug/L 05/05/2022 1042 Benzene ND 1 0.50 0.40 ug/L 05/05/2022 1042 Bromochloromethane ND 1 0.50 0.40 ug/L 05/05/2022 1042 Bromodichloromethane ND 1 0.50 0.40 ug/L 05/05/2022 1042 Bromoform ND 1 0.50 0.40 ug/L 05/05/2022 1042 Bromomethane (Methyl bromide) ND 1 0.50 0.40 ug/L 05/05/2022 1042 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/05/2022 1042 Carbon disulfide ND 1 0.50 0.40 ug/L 05/05/2022 1042 Carbon tetrachloride ND 1 0.50 0.40 ug/L 05/05/2022 1042 Chlorobenzene ND 1 0.50 0.40 ug/L 05/05/2022 1042 Chloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1042 Chloroform ND 1 0.50 0.40 ug/L 05/05/2022 1042 Chloromethane (Methyl chloride) ND 1 0.50 0.40 ug/L 05/05/2022 1042 1,2-Dibromo-3-chloropropane (DBCP) ND 1 0.50 0.40 ug/L 05/05/2022 1042 Dibromochloromethane ND 1 0.50 0.40 ug/L 05/05/2022 1042 1,2-Dibromoethane (EDB) ND 1 0.50 0.40 ug/L 05/05/2022 1042 Dibromomethane (Methylene bromide) ND 1 0.50 0.40 ug/L 05/05/2022 1042 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.40 ug/L 05/05/2022 1042 1,2-Dichlorobenzene ND 1 0.50 0.40 ug/L 05/05/2022 1042 1,4-Dichlorobenzene ND 1 0.50 0.40 ug/L 05/05/2022 1042 1,1-Dichloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1042 1,2-Dichloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1042 1,1-Dichloroethene ND 1 0.50 0.40 ug/L 05/05/2022 1042 cis- 1,2-Dichloroethene ND 1 0.50 0.40 ug/L 05/05/2022 1042 trans- 1,2-Dichloroethene ND 1 0.50 0.40 ug/L 05/05/2022 1042 1,2-Dichloropropane ND 1 0.50 0.40 ug/L 05/05/2022 1042 cis- 1,3-Dichloropropene ND 1 0.50 0.40 ug/L 05/05/2022 1042 trans- 1,3-Dichloropropene ND 1 0.50 0.40 ug/L 05/05/2022 1042 Ethylbenzene ND 1 0.50 0.40 ug/L 05/05/2022 1042 2-Hexanone ND 1 10 2.0 ug/L 05/05/2022 1042 Methacrylonitrile ND 1 5.0 2.0 ug/L 05/05/2022 1042 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/05/2022 1042 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/05/2022 1042 Methylene chloride ND 1 0.50 0.40 ug/L 05/05/2022 1042 Styrene ND 1 0.50 0.41 ug/L 05/05/2022 1042 1,1,1,2-Tetrachloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1042 1,1,2,2-Tetrachloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1042 Tetrachloroethene ND 1 0.50 0.40 ug/L 05/05/2022 1042 Tetrahydrofuran ND 1 5.0 1.0 ug/L 05/05/2022 1042 Toluene ND 1 0.50 0.40 ug/L 05/05/2022 1042 1,1,1-Trichloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1042 1,1,2-Trichloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1042 Trichloroethene ND 1 0.50 0.40 ug/L 05/05/2022 1042 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 282 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ40563-001 Matrix: Aqueous Batch:40563 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Trichlorofluoromethane ND 1 0.50 0.40 ug/L 05/05/2022 1042 1,2,3-Trichloropropane ND 1 0.50 0.40 ug/L 05/05/2022 1042 Vinyl acetate ND 1 5.0 1.2 ug/L 05/05/2022 1042 Vinyl chloride ND 1 0.50 0.40 ug/L 05/05/2022 1042 Xylenes (total) ND 1 1.0 0.40 ug/L 05/05/2022 1042 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 90 70-130 1,2-Dichloroethane-d4 100 70-130 Toluene-d8 91 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 283 of 331 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ40563-002 Matrix: Aqueous Batch:40563 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 92 1 92 60-140 05/05/2022 0953 Acrylonitrile 100 96 1 96 70-130 05/05/2022 0953 Benzene 50 46 1 93 70-130 05/05/2022 0953 Bromochloromethane 50 42 1 84 70-130 05/05/2022 0953 Bromodichloromethane 50 45 1 91 70-130 05/05/2022 0953 Bromoform 50 47 1 94 70-130 05/05/2022 0953 Bromomethane (Methyl bromide) 50 45 1 90 70-130 05/05/2022 0953 2-Butanone (MEK) 100 100 1 101 70-130 05/05/2022 0953 Carbon disulfide 50 43 1 86 70-130 05/05/2022 0953 Carbon tetrachloride 50 43 1 86 70-130 05/05/2022 0953 Chlorobenzene 50 45 1 90 70-130 05/05/2022 0953 Chloroethane 50 49 1 99 70-130 05/05/2022 0953 Chloroform 50 44 1 88 70-130 05/05/2022 0953 Chloromethane (Methyl chloride) 50 49 1 98 60-140 05/05/2022 0953 1,2-Dibromo-3-chloropropane (DBCP) 50 47 1 94 70-130 05/05/2022 0953 Dibromochloromethane 50 45 1 91 70-130 05/05/2022 0953 1,2-Dibromoethane (EDB) 50 47 1 95 70-130 05/05/2022 0953 Dibromomethane (Methylene bromide) 50 44 1 88 70-130 05/05/2022 0953 trans- 1,4-Dichloro-2-butene 50 52 1 103 70-130 05/05/2022 0953 1,2-Dichlorobenzene 50 45 1 90 70-130 05/05/2022 0953 1,4-Dichlorobenzene 50 44 1 88 70-130 05/05/2022 0953 1,1-Dichloroethane 50 46 1 92 70-130 05/05/2022 0953 1,2-Dichloroethane 50 45 1 90 70-130 05/05/2022 0953 1,1-Dichloroethene 50 43 1 86 70-130 05/05/2022 0953 cis- 1,2-Dichloroethene 50 45 1 91 70-130 05/05/2022 0953 trans- 1,2-Dichloroethene 50 45 1 90 70-130 05/05/2022 0953 1,2-Dichloropropane 50 48 1 95 70-130 05/05/2022 0953 cis- 1,3-Dichloropropene 50 49 1 99 70-130 05/05/2022 0953 trans- 1,3-Dichloropropene 50 50 1 101 70-130 05/05/2022 0953 Ethylbenzene 50 49 1 99 70-130 05/05/2022 0953 2-Hexanone 100 110 1 110 70-130 05/05/2022 0953 Methacrylonitrile 250 240 1 96 70-130 05/05/2022 0953 Methyl iodide (lodomethane) 50 42 1 85 70-130 05/05/2022 0953 4-Methyl-2-pentanone 100 110 1 109 70-130 05/05/2022 0953 Methylene chloride 50 42 1 83 70-130 05/05/2022 0953 Styrene 50 52 1 104 70-130 05/05/2022 0953 1,1,1,2-Tetrachloroethane 50 45 1 90 70-130 05/05/2022 0953 1,1,2,2-Tetrachloroethane 50 48 1 96 70-130 05/05/2022 0953 Tetrachloroethene 50 45 1 89 70-130 05/05/2022 0953 Tetrahydrofuran 50 48 1 96 70-130 05/05/2022 0953 Toluene 50 49 1 99 70-130 05/05/2022 0953 1,1,1-Trichloroethane 50 44 1 89 70-130 05/05/2022 0953 1,1,2-Trichloroethane 50 46 1 91 70-130 05/05/2022 0953 Trichloroethene 50 44 1 88 70-130 05/05/2022 0953 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 284 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ40563-002 Matrix: Aqueous Batch:40563 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Trichlorofluoromethane 50 45 1 90 70-130 05/05/2022 0953 1,2,3-Trichloropropane 50 45 1 91 70-130 05/05/2022 0953 Vinyl acetate 50 47 1 93 60-140 05/05/2022 0953 Vinyl chloride 50 48 1 95 70-130 05/05/2022 0953 Xylenes (total) 100 100 1 100 70-130 05/05/2022 0953 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 97 70-130 1,2-Dichloroethane-d4 90 70-130 Toluene-d8 92 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 285 of 331 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ40576-001 Matrix: Aqueous Batch:40576 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 10 4.0 ug/L 05/05/2022 1009 Acrylonitrile ND 1 5.0 0.80 ug/L 05/05/2022 1009 Benzene ND 1 0.50 0.40 ug/L 05/05/2022 1009 Bromochloromethane ND 1 0.50 0.40 ug/L 05/05/2022 1009 Bromodichloromethane ND 1 0.50 0.40 ug/L 05/05/2022 1009 Bromoform ND 1 0.50 0.40 ug/L 05/05/2022 1009 Bromomethane (Methyl bromide) ND 1 0.50 0.40 ug/L 05/05/2022 1009 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/05/2022 1009 Carbon disulfide ND 1 0.50 0.40 ug/L 05/05/2022 1009 Carbon tetrachloride ND 1 0.50 0.40 ug/L 05/05/2022 1009 Chlorobenzene ND 1 0.50 0.40 ug/L 05/05/2022 1009 Chloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1009 Chloroform ND 1 0.50 0.40 ug/L 05/05/2022 1009 Chloromethane (Methyl chloride) ND 1 0.50 0.40 ug/L 05/05/2022 1009 1,2-Dibromo-3-chloropropane (DBCP) ND 1 0.50 0.40 ug/L 05/05/2022 1009 Dibromochloromethane ND 1 0.50 0.40 ug/L 05/05/2022 1009 1,2-Dibromoethane (EDB) ND 1 0.50 0.40 ug/L 05/05/2022 1009 Dibromomethane (Methylene bromide) ND 1 0.50 0.40 ug/L 05/05/2022 1009 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.40 ug/L 05/05/2022 1009 1,2-Dichlorobenzene ND 1 0.50 0.40 ug/L 05/05/2022 1009 1,4-Dichlorobenzene ND 1 0.50 0.40 ug/L 05/05/2022 1009 1,1-Dichloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1009 1,2-Dichloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1009 1,1-Dichloroethene ND 1 0.50 0.40 ug/L 05/05/2022 1009 cis- 1,2-Dichloroethene ND 1 0.50 0.40 ug/L 05/05/2022 1009 trans- 1,2-Dichloroethene ND 1 0.50 0.40 ug/L 05/05/2022 1009 1,2-Dichloropropane ND 1 0.50 0.40 ug/L 05/05/2022 1009 cis- 1,3-Dichloropropene ND 1 0.50 0.40 ug/L 05/05/2022 1009 trans- 1,3-Dichloropropene ND 1 0.50 0.40 ug/L 05/05/2022 1009 Ethylbenzene ND 1 0.50 0.40 ug/L 05/05/2022 1009 2-Hexanone ND 1 10 2.0 ug/L 05/05/2022 1009 Methacrylonitrile ND 1 5.0 2.0 ug/L 05/05/2022 1009 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/05/2022 1009 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/05/2022 1009 Methylene chloride ND 1 0.50 0.40 ug/L 05/05/2022 1009 Styrene ND 1 0.50 0.41 ug/L 05/05/2022 1009 1,1,1,2-Tetrachloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1009 1,1,2,2-Tetrachloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1009 Tetrachloroethene ND 1 0.50 0.40 ug/L 05/05/2022 1009 Tetrahydrofuran ND 1 5.0 1.0 ug/L 05/05/2022 1009 Toluene ND 1 0.50 0.40 ug/L 05/05/2022 1009 1,1,1-Trichloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1009 1,1,2-Trichloroethane ND 1 0.50 0.40 ug/L 05/05/2022 1009 Trichloroethene ND 1 0.50 0.40 ug/L 05/05/2022 1009 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 286 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ40576-001 Matrix: Aqueous Batch:40576 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Trichlorofluoromethane ND 1 0.50 0.40 ug/L 05/05/2022 1009 1,2,3-Trichloropropane ND 1 0.50 0.40 ug/L 05/05/2022 1009 Vinyl acetate ND 1 5.0 1.2 ug/L 05/05/2022 1009 Vinyl chloride ND 1 0.50 0.40 ug/L 05/05/2022 1009 Xylenes (total) ND 1 1.0 0.40 ug/L 05/05/2022 1009 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 95 70-130 Toluene-d8 96 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 287 of 331 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ40576-002 Matrix: Aqueous Batch:40576 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 120 1 124 60-140 05/05/2022 0922 Acrylonitrile 100 96 1 96 70-130 05/05/2022 0922 Benzene 50 45 1 89 70-130 05/05/2022 0922 Bromochloromethane 50 46 1 91 70-130 05/05/2022 0922 Bromodichloromethane 50 42 1 85 70-130 05/05/2022 0922 Bromoform 50 38 1 75 70-130 05/05/2022 0922 Bromomethane (Methyl bromide) 50 46 1 91 70-130 05/05/2022 0922 2-Butanone (MEK) 100 110 1 109 70-130 05/05/2022 0922 Carbon disulfide 50 41 1 82 70-130 05/05/2022 0922 Carbon tetrachloride 50 40 1 79 70-130 05/05/2022 0922 Chlorobenzene 50 44 1 89 70-130 05/05/2022 0922 Chloroethane 50 45 1 90 70-130 05/05/2022 0922 Chloroform 50 44 1 88 70-130 05/05/2022 0922 Chloromethane (Methyl chloride) 50 46 1 92 60-140 05/05/2022 0922 1,2-Dibromo-3-chloropropane (DBCP) 50 42 1 84 70-130 05/05/2022 0922 Dibromochloromethane 50 42 1 83 70-130 05/05/2022 0922 1,2-Dibromoethane (EDB) 50 46 1 93 70-130 05/05/2022 0922 Dibromomethane (Methylene bromide) 50 45 1 91 70-130 05/05/2022 0922 trans- 1,4-Dichloro-2-butene 50 35 1 70 70-130 05/05/2022 0922 1,2-Dichlorobenzene 50 46 1 91 70-130 05/05/2022 0922 1,4-Dichlorobenzene 50 44 1 88 70-130 05/05/2022 0922 1,1-Dichloroethane 50 44 1 88 70-130 05/05/2022 0922 1,2-Dichloroethane 50 45 1 91 70-130 05/05/2022 0922 1,1-Dichloroethene 50 43 1 87 70-130 05/05/2022 0922 cis- 1,2-Dichloroethene 50 45 1 89 70-130 05/05/2022 0922 trans- 1,2-Dichloroethene 50 44 1 87 70-130 05/05/2022 0922 1,2-Dichloropropane 50 45 1 91 70-130 05/05/2022 0922 cis- 1,3-Dichloropropene 50 48 1 95 70-130 05/05/2022 0922 trans- 1,3-Dichloropropene 50 47 1 94 70-130 05/05/2022 0922 Ethylbenzene 50 46 1 92 70-130 05/05/2022 0922 2-Hexanone 100 100 1 104 70-130 05/05/2022 0922 Methacrylonitrile 250 240 1 97 70-130 05/05/2022 0922 Methyl iodide (lodomethane) 50 43 1 87 70-130 05/05/2022 0922 4-Methyl-2-pentanone 100 100 1 101 70-130 05/05/2022 0922 Methylene chloride 50 42 1 84 70-130 05/05/2022 0922 Styrene 50 49 1 97 70-130 05/05/2022 0922 1,1,1,2-Tetrachloroethane 50 43 1 86 70-130 05/05/2022 0922 1,1,2,2-Tetrachloroethane 50 45 1 90 70-130 05/05/2022 0922 Tetrachloroethene 50 45 1 90 70-130 05/05/2022 0922 Tetrahydrofuran 50 47 1 95 70-130 05/05/2022 0922 Toluene 50 46 1 91 70-130 05/05/2022 0922 1,1,1-Trichloroethane 50 43 1 86 70-130 05/05/2022 0922 1,1,2-Trichloroethane 50 44 1 88 70-130 05/05/2022 0922 Trichloroethene 50 45 1 89 70-130 05/05/2022 0922 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 288 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ40576-002 Matrix: Aqueous Batch:40576 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Trichlorofluoromethane 50 43 1 87 70-130 05/05/2022 0922 1,2,3-Trichloropropane 50 46 1 92 70-130 05/05/2022 0922 Vinyl acetate 50 47 1 95 60-140 05/05/2022 0922 Vinyl chloride 50 43 1 85 70-130 05/05/2022 0922 Xylenes (total) 100 93 1 93 70-130 05/05/2022 0922 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 88 70-130 Toluene-d8 91 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 289 of 331 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: XQ41173-001 Matrix: Aqueous Batch:41173 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane ND 1 3.0 1.0 ug/L 05/11/2022 0002 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 97 40-170 ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 290 of 331 QC Data for Lot Number: XD27004 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: XQ41173-002 Matrix: Aqueous Batch:41173 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 51 1 103 70-130 05/10/2022 2236 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 114 40-170 ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 291 of 331 QC Data for Lot Number: XD27004 Semivolatile Organic Compounds by GC/MS - MB Sample ID: XQ40389-001 Matrix: Aqueous Batch:40389 Prep Method: 3520C Analytical Method: 8270D Prep Date: 05/04/2022 1530 Parameter Result Q Dil LOQ DL Units Analysis Date bis(2-Ethy1hexy1)phtha1ate ND 1 4.0 0.50 ug/L 05/06/20221812 Acceptance Surrogate Q % Rec Limit 2-Fluorobiphenyl 74 37-129 2-Fluorophenol 44 24-127 Nitrobenzene-d5 62 38-127 Phenol-d5 55 28-128 TerphenyIA14 85 10-148 2,4,6-Tribromophenol 87 35-144 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 292 of 331 Semivolatile Organic Compounds by GC/MS - LCS Sample ID: XQ40389-002 Matrix: Aqueous Batch:40389 Prep Method: 3520C Analytical Method: 8270D Prep Date: 05/04/2022 1530 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date bis(2-Ethy1hexy1)phtha1ate 40 25 1 63 30-130 05/06/20221838 Surrogate Q % Rec Acceptance Limit 2-Fluorobiphenyl 84 37-129 2-Fluorophenol 80 24-127 Nitrobenzene-d5 83 38-127 Phenol-d5 80 28-128 TerphenyIA14 84 10-148 2,4,6-Tribromophenol 98 35-144 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XD27004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 293 of 331 Dissolved Gases - MB Sample ID: XQ40722-001 Matrix: Aqueous Batch:40722 Analytical Method: RSK - 175 Parameter Result Q Dil LOQ DL Units Analysis Date Ethane ND 1 10 2.5 ug/L 05/06/20221351 Ethene ND 1 10 2.5 ug/L 05/06/20221351 Methane 2.8 J 1 10 2.5 ug/L 05/06/20221351 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 294 of 331 QC Data for Lot Number: XD27004 Dissolved Gases - LCS Sample ID: XQ40722-002 Matrix: Aqueous Batch:40722 Analytical Method: RSK - 175 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Ethane 550 600 1 108 70-130 05/06/20221247 Ethene 520 540 1 104 70-130 05/06/20221247 Methane 300 260 1 87 70-130 05/06/20221247 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 295 of 331 QC Data for Lot Number: XD27004 Dissolved Gases - LCSD Sample ID: XQ40722-003 Matrix: Aqueous Batch:40722 Analytical Method: RSK - 175 Spike Amount Result %Rec % RPD Parameter (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Ethane 550 600 1 108 0.055 70-130 30 05/06/20221301 Ethene 520 540 1 104 0.27 70-130 30 05/06/20221301 Methane 300 260 1 87 0.31 70-130 30 05/06/20221301 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 296 of 331 QC Data for Lot Number: XD27004 Dissolved Gases - MB Sample ID: XQ41098-001 Matrix: Aqueous Batch: 41098 Analytical Method: RSK - 175 Parameter Result Q Dil LOQ DL Units Analysis Date Ethane ND 1 10 2.5 ug/L 05/10/20221215 Ethene ND 1 10 2.5 ug/L 05/10/20221215 Methane 2.9 J 1 10 2.5 ug/L 05/10/20221215 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 297 of 331 QC Data for Lot Number: XD27004 Dissolved Gases - LCS Sample ID: XQ41098-002 Matrix: Aqueous Batch: 41098 Analytical Method: RSK - 175 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Ethane 550 540 1 97 70-130 05/10/20221141 Ethene 520 480 1 92 70-130 05/10/20221141 Methane 300 210 1 73 70-130 05/10/20221141 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 298 of 331 QC Data for Lot Number: XD27004 Dissolved Gases - MB Sample ID: XQ41253-001 Matrix: Aqueous Batch: 41253 Analytical Method: RSK - 175 Parameter Result Q Dil LOQ DL Units Analysis Date Ethane ND 1 10 2.5 ug/L 05/11/20221038 Ethene ND 1 10 2.5 ug/L 05/11/20221038 Methane 3.1 J 1 10 2.5 ug/L 05/11/20221038 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 299 of 331 QC Data for Lot Number: XD27004 Dissolved Gases - LCS Sample ID: XQ41253-002 Matrix: Aqueous Batch: 41253 Analytical Method: RSK - 175 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Ethane 550 550 1 99 70-130 05/11/2022 0952 Ethene 520 510 1 99 70-130 05/11/2022 0952 Methane 300 300 1 101 70-130 05/11/2022 0952 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 300 of 331 QC Data for Lot Number: XD27004 Dissolved Gases - LCSD Sample ID: XQ41253-003 Matrix: Aqueous Batch: 41253 Analytical Method: RSK - 175 Spike Amount Result %Rec % RPD Parameter (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Ethane 550 540 1 98 1.2 70-130 30 05/11/20221006 Ethene 520 510 1 99 0.70 70-130 30 05/11/20221006 Methane 300 300 1 101 0.28 70-130 30 05/11/20221006 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 301 of 331 QC Data for Lot Number: XD27004 ICP-MS Metals - MB Sample ID: XQ39642-001 Matrix: Aqueous Batch: 39642 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/28/2022 0906 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 04/29/20221339 Arsenic ND 1 2.0 1.3 ug/L 04/29/20221339 Barium ND 1 5.0 1.3 ug/L 04/29/20221339 Beryllium ND 1 0.40 0.15 ug/L 04/29/20221339 Cadmium ND 1 0.50 0.13 ug/L 04/29/20221339 Chromium ND 1 5.0 1.3 ug/L 04/29/20221339 Cobalt ND 1 5.0 1.3 ug/L 04/29/20221339 Copper ND 1 5.0 1.3 ug/L 04/29/20221339 Iron ND 1 50 13 ug/L 04/29/20221339 Lead ND 1 1.0 0.25 ug/L 04/29/20221339 Manganese ND 1 5.0 1.3 ug/L 04/29/20221339 Nickel ND 1 5.0 1.3 ug/L 04/29/20221339 Selenium ND 1 5.0 1.3 ug/L 04/29/20221339 Silver ND 1 1.0 0.25 ug/L 04/29/20221339 Thallium ND 1 0.50 0.15 ug/L 04/29/20221339 Vanadium ND 1 5.0 2.5 ug/L 04/29/20221339 Zinc ND 1 10 2.5 ug/L 04/29/20221339 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 302 of 331 QC Data for Lot Number: XD27004 ICP-MS Metals - LCS Sample ID: XQ39642-002 Matrix: Aqueous Batch: 39642 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/28/2022 0906 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 97 1 97 80-120 04/29/20221343 Arsenic 100 97 1 97 80-120 04/29/20221343 Barium 100 95 1 95 80-120 04/29/20221343 Beryllium 100 97 1 97 80-120 04/29/20221343 Cadmium 100 96 1 96 80-120 04/29/20221343 Chromium 100 98 1 98 80-120 04/29/20221343 Cobalt 100 96 1 96 80-120 04/29/20221343 Copper 100 99 1 99 80-120 04/29/20221343 Iron 1000 940 1 94 80-120 04/29/20221343 Lead 100 97 1 97 80-120 04/29/20221343 Manganese 100 97 1 97 80-120 04/29/20221343 Nickel 100 97 1 97 80-120 04/29/20221343 Selenium 100 96 1 96 80-120 04/29/20221343 Silver 100 97 1 97 80-120 04/29/20221343 Thallium 100 96 1 96 80-120 04/29/20221343 Vanadium 100 97 1 97 80-120 04/29/20221343 Zinc 100 97 1 97 80-120 04/29/20221343 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 303 of 331 QC Data for Lot Number: XD27004 ICP-MS Metals - MB Sample ID: XQ39927-001 Matrix: Aqueous Batch: 39927 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/30/2022 1038 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 05/02/20221318 Arsenic ND 1 2.0 1.3 ug/L 05/02/20221318 Barium ND 1 5.0 1.3 ug/L 05/02/20221318 Beryllium ND 1 0.40 0.15 ug/L 05/02/20221318 Cadmium ND 1 0.50 0.13 ug/L 05/02/20221318 Chromium ND 1 5.0 1.3 ug/L 05/02/20221318 Cobalt ND 1 5.0 1.3 ug/L 05/02/20221318 Copper ND 1 5.0 1.3 ug/L 05/02/20221318 Lead ND 1 1.0 0.25 ug/L 05/02/20221318 Nickel ND 1 5.0 1.3 ug/L 05/02/20221318 Selenium ND 1 5.0 1.3 ug/L 05/02/20221318 Silver 0.41 J 1 1.0 0.25 ug/L 05102/20221318 Thallium ND 1 0.50 0.15 ug/L 05/02/20221318 Vanadium ND 1 5.0 2.5 ug/L 05/02/20221318 Zinc ND 1 10 2.5 ug/L 05/02/20221318 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 304 of 331 QC Data for Lot Number: XD27004 ICP-MS Metals - LCS Sample ID: XQ39927-002 Matrix: Aqueous Batch: 39927 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/30/2022 1038 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 96 1 96 80-120 05/02/20221322 Arsenic 100 100 1 102 80-120 05/02/20221322 Barium 100 95 1 95 80-120 05/02/20221322 Beryllium 100 96 1 96 80-120 05/02/20221322 Cadmium 100 97 1 97 80-120 05/02/20221322 Chromium 100 100 1 101 80-120 05/02/20221322 Cobalt 100 100 1 102 80-120 05/02/20221322 Copper 100 100 1 103 80-120 05/02/20221322 Lead 100 95 1 95 80-120 05/02/20221322 Nickel 100 100 1 103 80-120 05/02/20221322 Selenium 100 97 1 97 80-120 05/02/20221322 Silver 100 98 1 98 80-120 05/02/20221322 Thallium 100 96 1 96 80-120 05/02/20221322 Vanadium 100 99 1 99 80-120 05/02/20221322 Zinc 100 100 1 101 80-120 05/02/20221322 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 305 of 331 QC Data for Lot Number: XD27004 ICP-MS Metals - MB Sample ID: XQ39935-001 Matrix: Aqueous Batch: 39935 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/30/2022 1125 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 05/03/20221602 Arsenic ND 1 2.0 1.3 ug/L 05/03/20221602 Barium ND 1 5.0 1.3 ug/L 05/03/20221602 Beryllium ND 1 0.40 0.15 ug/L 05/03/20221602 Cadmium ND 1 0.50 0.13 ug/L 05/03/20221602 Chromium ND 1 5.0 1.3 ug/L 05/03/20221602 Cobalt ND 1 5.0 1.3 ug/L 05/03/20221602 Copper ND 1 5.0 1.3 ug/L 05/03/20221602 Lead ND 1 1.0 0.25 ug/L 05/03/20221602 Nickel ND 1 5.0 1.3 ug/L 05/03/20221602 Selenium ND 1 5.0 1.3 ug/L 05/03/20221602 Silver ND 1 1.0 0.25 ug/L 05/03/20221602 Thallium ND 1 0.50 0.15 ug/L 05/03/20221602 Vanadium ND 1 5.0 2.5 ug/L 05/03/20221602 Zinc ND 1 10 2.5 ug/L 05/03/20221602 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 306 of 331 QC Data for Lot Number: XD27004 ICP-MS Metals - LCS Sample ID: XQ39935-002 Matrix: Aqueous Batch: 39935 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/30/2022 1125 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 100 1 103 80-120 05/03/20221606 Arsenic 100 100 1 102 80-120 05/03/20221606 Barium 100 100 1 102 80-120 05/03/20221606 Beryllium 100 110 1 113 80-120 05/03/20221606 Cadmium 100 100 1 103 80-120 05/03/20221606 Chromium 100 100 1 104 80-120 05/03/20221606 Cobalt 100 100 1 101 80-120 05/03/20221606 Copper 100 100 1 104 80-120 05/03/20221606 Lead 100 100 1 102 80-120 05/03/20221606 Nickel 100 100 1 103 80-120 05/03/20221606 Selenium 100 100 1 104 80-120 05/03/20221606 Silver 100 100 1 104 80-120 05/03/20221606 Thallium 100 98 1 98 80-120 05/03/20221606 Vanadium 100 100 1 103 80-120 05/03/20221606 Zinc 100 100 1 101 80-120 05/03/20221606 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 307 of 331 QC Data for Lot Number: XD27004 ICP-MS Metals - MB Sample ID: XQ39937-001 Matrix: Aqueous Batch: 39937 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/30/2022 1206 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 05/03/20221754 Arsenic ND 1 2.0 1.3 ug/L 05/03/20221754 Barium ND 1 5.0 1.3 ug/L 05/03/20221754 Beryllium ND 1 0.40 0.15 ug/L 05/03/20221754 Cadmium ND 1 0.50 0.13 ug/L 05/03/20221754 Chromium ND 1 5.0 1.3 ug/L 05/03/20221754 Cobalt ND 1 5.0 1.3 ug/L 05/03/20221754 Copper ND 1 5.0 1.3 ug/L 05/03/20221754 Iron ND 1 50 13 ug/L 05/03/20221754 Lead ND 1 1.0 0.25 ug/L 05/03/20221754 Manganese ND 1 5.0 1.3 ug/L 05/03/20221754 Nickel ND 1 5.0 1.3 ug/L 05/03/20221754 Selenium ND 1 5.0 1.3 ug/L 05/03/20221754 Silver ND 1 1.0 0.25 ug/L 05/03/20221754 Thallium ND 1 0.50 0.15 ug/L 05/03/20221754 Vanadium ND 1 5.0 2.5 ug/L 05/03/20221754 Zinc ND 1 10 2.5 ug/L 05/03/20221754 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 308 of 331 QC Data for Lot Number: XD27004 ICP-MS Metals - LCS Sample ID: XQ39937-002 Matrix: Aqueous Batch: 39937 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/30/2022 1206 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 100 1 105 80-120 05/03/20221758 Arsenic 100 100 1 101 80-120 05/03/20221758 Barium 100 100 1 101 80-120 05/03/20221758 Beryllium 100 110 1 106 80-120 05/03/20221758 Cadmium 100 100 1 104 80-120 05/03/20221758 Chromium 100 110 1 107 80-120 05/03/20221758 Cobalt 100 100 1 100 80-120 05/03/20221758 Copper 100 100 1 103 80-120 05/03/20221758 Iron 1000 960 1 96 80-120 05/03/20221758 Lead 100 100 1 100 80-120 05/03/20221758 Manganese 100 100 1 104 80-120 05/03/20221758 Nickel 100 100 1 103 80-120 05/03/20221758 Selenium 100 110 1 105 80-120 05/03/20221758 Silver 100 110 1 108 80-120 05/03/20221758 Thallium 100 99 1 99 80-120 05/03/20221758 Vanadium 100 110 1 105 80-120 05/03/20221758 Zinc 100 100 1 100 80-120 05/03/20221758 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 309 of 331 QC Data for Lot Number: XD27004 ICP-MS Metals - MS Sample ID: XD27004-033MS Matrix: Aqueous Batch: 39937 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/30/2022 1206 Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony ND 100 100 1 104 75-125 05/03/20221812 Arsenic ND 100 100 1 100 75-125 05/03/20221812 Barium 15 100 120 1 101 75-125 05/03/20221812 Beryllium ND 100 110 1 106 75-125 05/03/20221812 Cadmium ND 100 100 1 103 75-125 05/03/20221812 Chromium ND 100 110 1 106 75-125 05/03/20221812 Cobalt ND 100 98 1 98 75-125 05/03/20221812 Copper ND 100 100 1 102 75-125 05/03/20221812 Lead ND 100 100 1 102 75-125 05/03/20221812 Nickel ND 100 99 1 99 75-125 05/03/20221812 Selenium ND 100 110 1 105 75-125 05/03/20221812 Silver ND 100 100 1 104 75-125 05/03/20221812 Thallium ND 100 98 1 98 75-125 05/03/20221812 Vanadium ND 100 110 1 105 75-125 05/03/20221812 Zinc ND 100 100 1 101 75-125 05/03/20221812 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 310 of 331 QC Data for Lot Number: XD27004 ICP-MS Metals - MSD Sample ID: XD27004-033MD Matrix: Aqueous Batch: 39937 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/30/2022 1206 Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Antimony ND 100 110 1 106 1.7 75-125 20 05/03/20221815 Arsenic ND 100 100 1 102 1.7 75-125 20 05/03/20221815 Barium 15 100 120 1 101 0.058 75-125 20 05/03/20221815 Beryllium ND 100 110 1 107 1.8 75-125 20 05/03/20221815 Cadmium ND 100 100 1 105 1.9 75-125 20 05/03/20221815 Chromium ND 100 110 1 107 1.3 75-125 20 05/03/20221815 Cobalt ND 100 100 1 101 2.3 75-125 20 05/03/20221815 Copper ND 100 100 1 104 1.6 75-125 20 05/03/20221815 Lead ND 100 100 1 102 0.080 75-125 20 05/03/20221815 Nickel ND 100 99 1 99 0.38 75-125 20 05/03/20221815 Selenium ND 100 100 1 102 3.3 75-125 20 05/03/20221815 Silver ND 100 110 1 107 2.6 75-125 20 05/03/20221815 Thallium ND 100 99 1 99 1.4 75-125 20 05/03/20221815 Vanadium ND 100 110 1 106 1.0 75-125 20 05/03/20221815 Zinc ND 100 100 1 104 3.2 75-125 20 05/03/20221815 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 311 of 331 QC Data for Lot Number: XD27004 CVAA -MB Sample ID: XQ39629-001 Matrix: Aqueous Batch: 39629 Prep Method: Analytical Method: 7470A Prep Date: 04/29/2022 0201 Parameter Result Q Dil LOQ DL Units Analysis Date Mercury ND 1 0.20 0.091 ug/L 04/29/2022 0714 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 312 of 331 QC Data for Lot Number: XD27004 CVAA - LCS Sample ID: XQ39629-002 Matrix: Aqueous Batch: 39629 Prep Method: Analytical Method: 7470A Prep Date: 04/29/2022 0201 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Mercury 2.0 1.7 1 86 80-120 04/29/2022 0716 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 313 of 331 QC Data for Lot Number: XD27004 CVAA -MB Sample ID: XQ40151-001 Matrix: Aqueous Batch:40151 Prep Method: Analytical Method: 7470A Prep Date: 05/03/2022 0301 Parameter Result Q Dil LOQ DL Units Analysis Date Mercury ND 1 0.20 0.091 ug/L 05/03/2022 0702 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 314 of 331 QC Data for Lot Number: XD27004 CVAA - LCS Sample ID: XQ40151-002 Matrix: Aqueous Batch:40151 Prep Method: Analytical Method: 7470A Prep Date: 05/03/2022 0301 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Mercury 2.0 1.7 1 85 80-120 05/03/2022 0704 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 315 of 331 QC Data for Lot Number: XD27004 CVAA - MS Sample ID: XD27004-046MS Matrix: Aqueous Batch:40151 Prep Method: Analytical Method: 7470A Prep Date: 05/03/2022 0301 Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Mercury ND 2.0 1.5 N 1 77 80-120 05/03/2022 0710 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 316 of 331 QC Data for Lot Number: XD27004 CVAA - MSD Sample ID: XD27004-046MD Matrix: Aqueous Batch:40151 Prep Method: Analytical Method: 7470A Prep Date: 05/03/2022 0301 Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Mercury ND 2.0 1.5 N 1 75 3.4 80-120 20 05/03/2022 0712 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 317 of 331 QC Data for Lot Number: XD27004 CVAA -MB Sample ID: XQ40633-001 Matrix: Aqueous Batch:40633 Prep Method: Analytical Method: 7470A Prep Date: 05/06/2022 0316 Parameter Result Q Dil LOQ DL Units Analysis Date Mercury ND 1 0.20 0.091 ug/L 05/06/2022 0827 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 318 of 331 QC Data for Lot Number: XD27004 CVAA - LCS Sample ID: XQ40633-002 Matrix: Aqueous Batch:40633 Prep Method: Analytical Method: 7470A Prep Date: 05/06/2022 0316 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Mercury 2.0 1.7 1 86 80-120 05/06/2022 0830 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 319 of 331 QC Data for Lot Number: XD27004 Chain of Custody and Miscellaneous Documents Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 320 of 331 PACE ANALYTICAL SERVICES, LLC h iL !� Al O' .J�. 2.p'ltg' � •.} P:. U-4 :1, L' +i. •.r7.�•4 M T. .'� ' a7 aT1�11 L 11 il,7 +. .... ..... .... i ..... _ g J k riZ• '. .... .. :. .sG �.s. .a'.' • � ..4 . ` " ' 'x[ij. `+v•l45't*z�yti5 7WUyfd �+;K1U}' 2 � 3 s,,,..titi � wH� IHes' � GC'`i 'u0� 1"� *Ya'''��ki � ..4 r- r d .. Ns in .. s C C U VV 'M 1' ['4V KY :'� .: V M y N 23 E a Fz z o K .� v I ;n c "ru R s a ei •n m 57z n F R j•" � 9 -J Sn I .} +a' Cs m o Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 321 of 331 PACE ANALYTICAL SERVICES, LLC � [�j V = � � � 4 _ � '""" � . � '. �.' I.I. 1 }.I+{: � ' ' I� ' � � �•� � . -13 .. - _ _ wr '`.�`}� .'a .: r - •:a.:. a' i .m. u�,e .o Lis u� .... . .,l%��� n.al ��E v�• 4 z �w 21 r}. C m 4 a rl 4L -- ?' u ' :.g a L 'r Cr E E NJ Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 322 of 331 PACE ANALYTICAL SERVICES, LLC Samples REmOpt Checklist ISnl (M6DQ3dG15 r�RA3dytri8! Re'rlsr+d;9J29/2D2 L) 4ss:�ingAa.lthprity, Pace E.YV - WOOL Pale 1 of 1 3JlnPle R.cteipt Checklist ( RQ C=itrnt- CDM Sm$b Ooo1zr Trwe. red 1' Idak= I't-r f air 2422 r . `�L)-?Vt)4 bor. t. Meam ofmcnrjpt: d Pace climf I -FPS' FedEx Oncc~ Yes f No I- WJ -re custndv sa4s pr; senr 4n dra curAff? — Ycs MID Nil 4 if castod X€kls were r:cscr'� -ere UN intact aid unb,-Oken7 Ph Strip ID: zr-xs _ _ hlormo Strip 1D: W' Tmtod . rr Ori inai tc nl)eratrma upon ret ipt r' 7orived (CDuTectPd_ } terrsperature upon receipt %8.31A Rnap�u 11]; NA 3) f 3.2 M f NA vC KA f NA nor NA � "A o�+ e[had; Qiempe:aturc k3lanl C n9t DCtklcs IR Gun { Crrectiotl Paccar_ 0 4 rl4crhad 41f caalnnt: ❑ - - C et Ice Ir;o Paolo Q DF, EDc 7�fgntc ❑ Yes C1 Ne ❑d NA-3. 1F remNraaL1r of and cs: l[x excaeGded 6.0"C +s'as Project Manager NDtJCr;d'+ Pw was Tlolificd by. pl[t w } email I face-to-face (circle ueL!). ✓ 'r No NA d. is the conithere- l rier's packing slip aiW- ied to this fam:? Yes No S. t4'em proper a.ustody wbr diires (relinyuishcoir-eeaivad) follow6P ✓ Yet No 6, Were sa.mply 1D.€ Umd;on the UUC? ✓ y,er, No 7. Wv1U sample IDS lisUdSM all sample oartai:reys? — Yes No 8. Vas co]Icotio:r dAtc el limo Lisled or. the too? Q Yes Ts -a 9, R°;, colleudm date &. r]= Jisiled oil all sample cn,rainers? 'r yw; ❑ o 70- Dirk u1j oontaiL-ier' IaoaJ inf—ati+m 11), da rime q( Yes No J J , 1��erC tests lu bed ked listed on the . C �0. ) A �7to d7e C�]C7 Yes M No 12. Did all s;unpJas arrive ill thcc prDper corflainer' for end, tv-tit ajdVar irr goad C,,,jirjorL (rulbroker, lids or;, etc.)? J Yes NO 13.WwIjequatcsamplevrrlu:rieavpilabEe? `ram Na 14, Wcre all sarnpTas r iVad wiLEti:r the J131din.9 tirne Or 49 E prrrs, Wiklicver conies first? ycs ✓ ND 15. Were airy sar iples contWiners r.]i(oirde anc) sam ins Not =isted (g, coc? [`] Yrs Q No O 16_ Far VOA and RSK-i75 samples, wara bubbles prCsent >°`pes,sirn'* (r{"vr 6mm in dbrur'E4r) :n coy of the'VOA vials? Yts N a NA 17- Wore al I DROAn7 talsln utrient Samples rcccive i aC a pH of - 2? Ye1i P40 � NIA 18. Wffea]I c;-anide sanjRs rece Ivad at rrplkj-k J? andsol-n- Samplesrcr•.ci%per' o-yra pfa y7 a Yes CJNc, EIN 1 aEl ppficalxk I+JI l M�'tynni el�i;eua *23, ]r6(F .3 (� 6.5m&r]-) smpple_& free q -ffid"al clrlarine? ❑ Yes ❑ No [DNA 211' Were client rernaj-kx+rcx4)ests (i.c, requested dllutians, I MSD designations, ate---j corrcatly tr ucrib4xi frM the COC lotto the cormment section in LIMS? yes +7 h1n 21. 1'Was the uot-; number lhleri on tee cm)tairrcr label? Ifves, Quoie Sanrplcprexeivaiiun (it4ust Ile c0mplaLad for any sa rp]c(s) ino¢n yp s y -or With t-eadupacc-) 5arnp[efs} " �wem received lworrvc in sA mple rcceii 'jnl with lx rx 13 1 69erved And were adjusl4xl accr�rdingl} — lk rrf circle onc, -US64, HNO3, IIC1, N-OH using.SR tt KA _ :Ins at`pr aervatiOr� if mam-eOun Dnepr se, w ti n ES nmded, please dote in Lire comments 1,eii>kk'. SnrrnlL,rt,L NA i I were reocivrd w:lh bubbl!s 56 Mtn in diurnoter- s3aroplDs(;) �A wele rCCetved wit'r TRC > 0.5 nWl. (I1wJus=ed acodingly in mPle , tt rt-cciving witlr rrxliu , tidies'.31fato (NkS2O.1) witJt 5]rea;ly Jt7. NA rt harcode labeta p'J&jby: KLWW GommediLs; Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 323 of 331 PACE ANALYTICAL SERVICES, LLC 6 :T dry' 9 r- � S � �Q 4d! � � '.at�• ��� �� :+•G.���- � S { ha'fI�N.� -_'�, LS �'.'' � x j [ 7 . 47 u r y 4...: :.U. ' a 01 n . Z' n• • � urn _ l .. "14 "rJ��,i�..(.�,1;',fii"I'7 _ r T, ki L' F. Q 2 _r X'; 4E :% L L E - a: C� v� V E -N yI `FI I'S `J- w NC5 q }Ir,'a cz v u' J.ii. E EL yy J J all r''�r +-M. I Q a •, ¢ c r3 r y i 3� A qq V _ 21 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 324 of 331 PACE ANALYTICAL SERVICES, LLC Samples Receipt Checklist jS]te} IIv UDIAC-1s1 ReAscd_%29J2024 Ruing Aut,ority_ Pace ENV • b%rCOC Page 1 o-f 1 SaMple ,Receipt Checklist { RQ Cart. f:LIN' SM"Lk Cool a IssSpe�tcd h r`ra6B: .t,LA, / O'tl27f�'922 Loot#. hD27li4`q ..w".I_' I I r ', J1wr1E L_j UP'Z$ IV I eCdLiar L�t OIthw.. _ .. d 't'cs T+Tn 1 _ lk'ere ctip nd}r Seals prQBOnt nn tho M q rl� — -- W Y6,1 F I No I Lj NA 12. I cmtod" seal wcre wcrG tha iu[aig and unbroken4 PH Strip ]D. 2"92 Chlorine strip Il): `A �Lc Tested by, Original tetpporEture ups reeupd 1 Deri x+Cd (Corres~wd) ternnerature upm receipt ° aSol;d Sna Ctt Ta- NA 27 23 0 2.4 f2.4 cC 3A 13.4 a ttiA fN4 e E} p hAe+thod: �Terraperntuie T31unk utist [3u.tl�w IR Gun ib: Irk Gun C-1KCtiou Filaw U klc#hod o;'c4olattt: Wet icr L-0 I= Rack; ❑ Dlv ko ❑ Ncgju YtrWD& ftetn'era[ur� of any' r,aalra aw�cded (110.7 MI Froje�cE varager M.tif:ed" M w7w TEoglird [sy� I,frone. eiraili face -to faca (�ircJe one}, YeltF.rttmerc[alcourir:'spackingslipatta[hedluthisfo�Yrs$ Ye'ercpraper rmtadv] rip.xdwee (resiinquisl�utlheceived) fogov�ed'f Yok�ere sartp[ Ids 'il3ced cm theC(]C7 crc xantiplcIDs lis[+.si on al. sample uunrailrs?A Yc4S collee'iam date & pale 1irjux[ Ou the C:UC r zYes Vo w� k c:nlIccliOli slate & time =istedas all sarttpla uorit Liner-? d 1'as Nu 7 Didull container laL�e] inGmnation (ID, dam, rime) agree with [fie C-0 7 " ZhTr, ] l H. Were bests to be peFfOrmrd listed an he 00': `lrs El No 12. T7irl all szenples arrive in the proper crsrUiners =vr eaalt test a ndl r in gaod t ar.didr,n (tinb oker, ]ids on, rke_)? _ No [3. WaS adequate Barn le VDIUma awailable9 cs No1 , 'Were all sa]tplrrS received within V, the holdi-n- Lucre or Yes hours Yes +, whichever comes ?irni? lJoire alt}•.2mpW GorgabMIN missingiaxoe� (circle one) aainpley Not [isti d or. ❑'f03 (DNa FIJA I$. For rCiAacid R IC-l7i amples,•wcre lrubb!es P"m;nt �]tess size"{S+"or 6trm in djpmetcr) iu a.ny aCtha VOA vials? EYES I`10 NA i 7. woreall DROhn OR1Vnutricnt sarn IC5 recv_ _ vtrd at a Hat < 2? 71 '(es 10 CIA TR_ Were LdI cyanide San]pleg received at a p_� > I" and sulfide simples -Cccivad ai a > 9-1 No �[jTl.4 19. Wm ril rpp iCa36:o 1�1i��1T cyianidwplfeno'v tSlCLIni Chlorine? �'fes , NO QtNA 20• W9Lrc cAarttrcm®tkslrrquests (i.c. requested dilutionF, MVMSn dt,�si.;-:natioes_ ere__•) co;;ectiy httrlwhbed from the COO intDthC aallir_te:ltseell(in in Lrmsl' Y2 NDl 12 1. %VM flip quo(c num ber ]isle,d IN, the container lu6t l7 I f ]' s. []unto rnple l'reWXVU6Dn (Must hr. contpielcd for any sa,rplr(s) inoDriCvt[y ptCscrt�ed rn with F•r ,t ispaoc.) MM'D lej t ,t WE. teach-ed incorverily Preserved and were. adjusted accordi t�[y amb le I Cceiuiug wide NA.t71. of circle 4nc: N2-", HK03, ]-TC -, -NaOH usirtg 5R # NA inc Df p ervasion NAWmore Man Dne pr%crvati v4 is needed, please note in the contrnellu he'ow. Smp1e(sj MA were raceivtd wit[t hubbies>6 MM itti diameter. 1' 51-- wpre reel' with TRC :5,,grngrL [ECiItly ISIr j a�sd vitro s� i! OCJ rOrairPly In 381riPrr. receiving w,'dI ypdiUj 1hiasu1r4tD (N%92%) s4ilh SiNa[y 117_ KA. buTcOde labels applied hv- _LC Dam: o +�r ta2z Commenrs, — Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 325 of 331 PACE ANALYTICAL SERVICES, LLC Hx- 93 4 I 1-� U EL i A -III ALI pi Z;.; X L I cc STF F717- CE J 4L p In' % ILL � ni E rj E0 7;-Fg z��- Cr Ch qj a Ir 1:3 Cr ej dn Z 0 A E Z d rj —M i Fe 14 dz n J� di- C Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 326 of 331 PACE ANALYTICAL SERVICES, LLC Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 327 of 331 PACE ANALYTICAL SERVICES, LLC A 71 � ... '. a•-i�4J 1 yi F 7 IL � L v 4� � di F a * A L S� 6 � a O 5 9 a � Isom 4 jA x Wk vIkk . J - _ I a ` W' .--.- � ,� y f +'q'' •S k°� 4 TI 4� O a Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 328 of 331 3 1 C • 3.:� 7 T t- K H o .n ip M1 d 3 `m ' r dt PACE ANALYTICAL SERVICES, LLC .. S dz Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 329 of 331 PACE ANALYTICAL SERVICES, LLC Samptes Receipt ChL%tktl5z(sRE) {mcoo1lil Hevlsed�]/29{ O o .. - rellraa�ylkstt Issuing Authority Pat* l - WCOL Pagelo{1 Sample Roil C<hecldist (SRC) Clicztt j'7 ,h iL Cooicr Ins �cte� rdale: !' {7 cn+ i.or il� 4 Means L&f4eCeipt= Pace Client UPS 7X Olher. Yc WQ- I I 1 _ Were custody seals pro4ont 011 11Lc .0 lc><:'LJ — Ymi Lj No h1 4 2.16NAodv sea]K wore t�tient, were they inMet abd unbroll i Ship Ili_ ZJ _ C3%1@rJl Strip ID: N 57- Testelt lay. 5 S ri tIA1111erature upon receipt f l riued (CllCll w4ripr-ratan upon rcceipi %Slalid Mall ID. { ` • S,D } �,C °C itFr, } to- oC Rr(l ,rPjf3 etc P dill [Eltemparalnl re Filmic Ok mst BoUles , I fifth IC> IR Oun Correction Fac[ar; Me#hpd Uf oaulrtrtt. �1�Vet Ire 1ctt Z'ac3cS ❑ D lacvoc ❑ Yes hla }4 if temperaatura of �xy t>o-n ler execried b.4°C. was Prljeet Menl<ger Notified? PM was N-r ifmd by: phom { eltt�il 1 01r&trrfat:e{eirelle Otte), Yes 1tin NJl 4_ [s the e,fxuxterc.rul urnirect s tmcls g a]! i oltadivd i0 this fnrr117 es Rro 5, Were CU!G dy } C.dures (rallinquishedircmivedl fallowed7 es NO:b, Were gamplfe Il3s lwirad an em C ? es No 7_ We>i a scruple 1Ds listed as all wvrnpto eou[ainars? Vas LjNa J& WIM C011ection data & tfine ]fisted on the COO? 4s LJ No 9. Wl ealleadr5l lane tune listed on A satel cantatners7 Yes TNo 10_ Did all Cahil rlfX label htfarmaEilm (ID, date} time) aW= with the 0OC7 ''es No 1 L. Wem testy to be peTl5i ied listed a� the C3OC! i=I Yess ©Tti n 12, Did AT %ai lei m-dvti in The Pill r:antuinors fickr each test.@iu_ifar in good e6Ca11t;orb (1311l [ids tan, etc,)?: 1+iCr 1-3_ WaN adequmte Gam b&V011 a%railabj6 y N 14. Wert ail san4drn rcmYed with' i,_the holds tGmG qx 48 t,a�s, whicill ej]mdA tirstF es M 15. Were arty MHm ks caltitai i651a 'exC+'3s {circle one) Sam 111 Not listed Og COG? ❑ 4'e.s � DNA 16. For LrC1h Atld RSK-175 aamF s, wer4 bubblesr Oresent >"pea -size" ClTor 6iism in diameter) in any of the VOA vial.sF No NA 17. Were all DRt]hnetaWnrl.Mient ss mPICR received at a PH of � �7 EffYes ND NA is, Wore all cyani de. sm les received a# a pill � 12 and s[tlGde -iq les ra4eiWd at a pH > 9? ❑ ycz ❑ No A 19_ Were a appiic a _ "1 _ fcyaaid na1 G25.1' S.3 (� mg� } saa„xplcs fine a riduel cltilot'dtic° E] Yrs E] No. EaNA 20. Rr2ro C]lEttf reap l'l ;r�quesis OZ. refine � dilutians, MSIMSI? dt;9ipatioa5, cta.__} cometiyIh mscrilmd Cro¢i the C OC into ll cornmeat &CGt[Ou in LIi49? I 'e_s No::: 21_ War, the irate number 09cd on tiro camrainar label? if rs, Qaate lr Sample l" rescrv4tion {'vlrtst be Completed far any �ample(s) iF[Wl:reat]y greServi d or with fi-aw -q=e.) simple(s) ! were received itsowrecll preecrved and were adjusiwd zmxordill in sample receiving %vide ,S 4L of circle ono: lfil HNO3, HCI, N OHusing SR N _ [ me of praserval ion If more than one �reseryrptivo is needed, pltaw torte ire the eomril bcluw- alatl�le{s) r A ' wl received with bubb3ea >6 mm in (fiayiewl.. SHmples(s) i WM rOCeived �Ylil! 'TRC -r 05 ttth{I , a {lf -t19 IS fJv }and tivere odjustcd aeoardil in Sample receiylu,g with sadinm thipsrttke (NnaS�Oe) will Shealy Imo; _ _pfl�Y SM baraock labDla applied by. _.. Dale; �y . C ommants- ` + + ,• S , aI Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 330 of 331 PACE ANALYTICAL SERVICES. LLC PA p gll N. ? CK 7.1 ...... r ..._.. '�.�. ��.� ,� Imo. '• j — a E'.._ �` -. '. ,..tip � •:�`��jr�'�'" :_ .. �:. . gL Li 2 C + z i Do ro # tln 9c� Z� 11 � IM u V 4 K- a> k o a } L I I f +A = a m +1 N Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 331 of 331 Y v U �m ;X _ � C W