Loading...
HomeMy WebLinkAbout0601_AveryCounty_MSWLF_Jun22LFG_FID1684669_20220621DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 SMITH GARDNER ADDRESS TEL WEB 14 N. Boylan Avenue, Raleigh NC 27603 919.828.0577 www.smithgardnerinc.com June 20, 2022 Ms. Jaclynne Drummond NCDENR DWM Solid Waste Section 2090 U.S. 70 Highway Swannanoa, North Carolina 28778-8211 RE: Operations, Monitoring, and Maintenance Report — June 2022 Avery County Closed MSW Landfill(Permit No. 06-01) Spruce Pine, North Carolina Dear Ms. Drummond: On behalf of Avery County (County), Smith Gardner, Inc. (S+G) is pleased to present this report regarding the operation and maintenance (0&M) of the Avery County Closed MSW Landfill (Permit No. 06-011 Landfill Gas Collection and Control System (LFGCCS), and the perimeter monitoring probes for June 2022. Site details are provided below. SITE HISTORY The Avery County Closed MSW landfill is located approximately 0.6 miles southeast of the intersection of Highway 19 and Brushy Creek Mountain Road next to the Avery County Airport and the Unimin Corporation mine facility. There is no active mining in the immediate vicinity of the landfill. The MSW landfill was operated from 1970 until it closed in 1993. The property consists of approximately 14.4 acres, with the landfill footprint occupying approximately 9.6 acres of the site. Landfill topography ranges in elevation from approximately 2770 ft. msl to 2670 ft. msl, and slopes downhill toward Brushy Creek. Landfill gas monitoring and LFGCCS maintenance is completed on a monthly basis due to landfill gas concentrations detected in monitoring probes off -site. LFG COLLECTION AND CONTROL SYSTEM MONITORING ACTIVITIES The site has an active Landfill Gas Collection and Control System (LFGCCS) consisting of 10 landfill gas extraction wells (W-1 through W-10), HDPE piping for transmission of collected landfill gas, a one (1) horsepower blower, a condensate trap and storage tank, a candlestick flare, and associated valves and gauges. Well field and flare station data are provided in the attached Table 1. DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 Ms. Drummond June 20, 2022 Page 2 of 4 LFG Extraction Well Field • W-1 through W-10: S+G performed methane (CH4), oxygen (02), and carbon dioxide (CO2) monitoring as well as temperature and pressure monitoring. In general, gas quality varies across the wellfield. All wells with the exception of W-6 and W-10 had recorded oxygen levels below 5% this sampling event. The wells will continue to be tuned to limit the concentration of oxygen in the landfill gas. Flare Station Gas quality measured at the flare is nominal with low levels recorded of methane, and moderate levels recorded of oxygen. The wellfield will continue to be monitored, tuned, and maintained as necessary to identify potential issues with the system and to improve gas quality levels. LFG MONITORING WELL (PERIMETER) MONITORING PROGRAM S+G performed monitoring of the perimeter LFG monitoring network during this event. The network consists of probes P-1 through P-13 located around the facility, and in some cases, on adjacent properties. Monitoring results for this month indicate the following probes have detectable methane concentrations: • P-1 • P-3 • P-7 Monitoring probes P-1, P-3, and P-7 all had observed concentrations above the lower explosive limit (LEL); the concentration in P-1 was 34.0%, P-3 was 1.1%, and P-7 was 17.4%. Overall, the three (3) probes with detectable levels of methane saw an increase in concentration from the May 2022 monitoring event. Attachment 1 includes the monitoring forms with results while Attachment 2 provides a CH4 concentration graph over time for monitoring wells that have historically had methane present. Monitoring of the current well network will continue, and data will be reported to NCDEQ and the County. CONCLUSIONS In general, the landfill gas extraction system continues to operate nominally. The landfill gas extraction wells will continue to be tuned to limit oxygen into the system. Monitoring probes P-1, P-3 and P-7 will continue to be monitored closely. S+G will continue to monitor the methane concentrations at the site monthly, and advise the County as needed on repairs required to maintain an effective collection system. DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 Ms. Drummond June 20, 2022 Page 3 of 4 The next monitoring event is scheduled for July 2022. If you have any questions, or require additional information, please contact us at your earliest convenience at 919-828-0577 or by e-mail (address below). Sincerely, SMITH GARDNER, INC. E DocuSigned by: �K'Vu' e.i V IQ.q.','"tl. 'ED73DOAEAB2442.. Daniel J. Pantaleo Environmental Technician ext. 140 daniel(asmithaardnerinc.com Attachments cc: Eric Foster - Avery County file CARO 4 EN SED O � SEA 'A 6/2 1369 DocuSigned by: Q oan'�EBS'myTh, P.G. Senior Hydrogeologist ext. 221 ioan(dsmithoardnerinc.com H:\Projects\Avery County INCI\02 AC Compliance\LFG Monitoring\MSW\2022\02 February 2022\February 2022 Avery MSW LFG Monitoring Report.docx 2 DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 Ms. Drummond June 20, 2022 Page 4 of 4 This page intentionally left blank. DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 11011,19 DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 This page intentionally left blank. DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 ti 41 qL low �. r` w i.• ��Lot mm r - `• ♦ i ► ' O ■ #i44 1• . y• + r CIE ! �* " w r \O.� AR- `gyp 1 y el ,� *fit•' � 6 �,. -7,/ ,,�J � r� •,w . .' *An 0 br f . I d, o �• � 1 I w +►•tin. — '%. Ir I • . r ■".1-1 7 O % �► #. AVERY COUNTY w �• . .� wV LANDFILL or a �r 1 ,,r �! •� A LEGEND T� ' 1 • . 04 0 EXISTING LANDFILL GAS PROBE • +• ® OFFSITE STRUCTURE TO BE ' •^ ■ MONITORED ,,. •�;�` REFERENCES «� 1. ADJACENT PROPERTIES ARE FROM AVERY COUNTY GIS MAPPING DEPARTMENT. _• r 2. MONITORING WELL LOCATIONS FROM FIELD SURVEY DATED 1/14/08, BY SURVEYING SOLUTIONS, P.C. 3. PROPERTY LINE FROM FIELD SURVEY DATED APRIL 9, 2010, BY .1�►.,N APPALACHIAN PROFESSIONAL LAND SURVEYORS & CONSULTANTS. • 4. LFG PROBES LOCATIONS FROM FIELD SURVEY DATED APRIL 9, 2010, BY APPALACHIAN PROFESSIONAL LAND SURVEYORS & CONSULTANTS. �, • • PROBE P-2, P-3, AND P-9 THROUGH P-13 LOCATIONS WERE NOT •; SURVEYED AND ARE APPROXIMATE. 411F 00 0 N 0 m w w z z a w � J O U-) a Z 1u U > C U Q G w Qa � Z J Cn o W m d CJ7 CCC,, GW GQ_7 Q Cn x cm Cn o J Lm J a c L z ' z o ..: O C-3 W C-3 rr x W d Q CJ7 DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 TABLES DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 This page intentionally left blank. DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 SMITH GARDNER • :;. 09 O• • • Is • � ? • • • DBE June 20, 2022 13( DJP IhAoeID [ate 04 02 CY EIa-w Irit.TerWatLre Irit.3atic Resare P4.2atic Resare Irit. Dff. Resare* Irit. Rav P4. R �em Resare m-d dcV yyyy % % % % deg F i n FPo i n I-0 i n I PO 3fm 3fm i n I PO AVERY-W1 6/14/2022 73.9 26.1 0.1 -0.1 762 -31.45 -31.44 0.012 0.4 0.4 -31.28 AVE RY-W2 6/14/2022 65.2 21.8 0.1 12.9 70.6 -37.05 -37.04 0.471 2.3 2.3 -40.88 AVERY-W3 6/14/2022 73 26.9 0.1 0 70.3 -39.92 -39.87 0.588 2.6 2.5 -40.69 AVE RY-W4 6/14/2022 12.7 19.5 1.1 66.7 95•7 -33.77 -33.93 -5.434 N/R N/R -39.5 AVERY-W5 6/14/2022 30.6 24.2 0.5 44.7 83•9 -39.26 -39.74 1.339 3.5 3.2 -41.22 AVERY-W6 6/14/2022 6.5 13.3 6.6 73.9 81.7 -20.73 -18.94 0.019 7.9 6.6 -41.26 AVERY-W7 6/14/2022 13.7 19.9 1.2 65.2 84.4 -29.73 -0.07 N/R N/R N/R -0.03 AVERY- W8 6/14/2022 54.6 32.8 0 12.6 88 - 39.88 - 39.9 0.01 5.8 4.7 - 40.06 AVERY- W9 6/14/2022 37.5 28.7 0 33.8 79 -19.13 - 39.54 - 0.002 N/R N / R - 40.45 AVERY-W10 6/14/2022 38.32 17.39 8.4 35.5 79•9 -38.78 -38.81 -0.001 N/R N/R -41.14 Av- FI ar e 6/14/2022 34.5 19.9 2.6 43 81.7 0.61 0.78 0.412 14.7 15 0.14 *The differential pressure measurement should be positive. A negative differential pressure may indicate no gas flow. Negative differential pressure can be the result of dirt or water obstructing the pitot tube perforations. Oderpulling by adjacent extraction wells may also result in negative pressure being displayed. NR= not recorded DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CD096 ATTACH MEN T1 PERIMETER MONITORING PROBE DATA DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 This page intentionally left blank. DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Avery County Closed MSW Landfill Permit Number: 06-01 Date of Sampling: 6/14/2022 NC Landfill Rule (.0500 or .1600): .0500 Name and Position of Sample Collector: Daniel J. Pantaleo, Staff Environmental Technician Type and Serial Number of Gas Meter: GEM5000, G506472 Date and Time of Field Calibration: 6/14/2022, 1130 Calibration Date of Gas Meter: 12/2021 Type of Field Calibration Gas (15115 or 35/50): 35/15 Expiration Date of Field Calibration Gas Canister: 10/2023 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 87 F Barometric Pressure: 30.09 in Hg General Weather Conditions: Partly Cloudy Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 Location or LFG Well ID Sample Tube Purge Time Time Pumped (s) Initial °,ZEL Stabilized °,,ZEL Of4L-H4 by Vohime %02 %CO2 Notes H 2 S p p m P-1 >60s 1407 >60s 680 680 34.0 2.6 16.1 7 P-2 >60s 1338 >60s 0 0 0.0 17.8 0.0 6 P-3 >60s 1334 >60s 22 22 1.1 16.0 2.2 5 P-4 >60s 1327 >60s 0 0 0.0 17.1 1.5 5 P-5 >60s 1323 >60s 0 0 0.0 16.6 2.3 5 P-6 >60s 1317 >60s 0 0 0.0 17.6 0.9 6 P-7 >60s 1312 >60s 348 348 17.4 0.6 12.8 7 P-8 >60s 1304 >60s 0 0 0.0 17.7 2.7 6 P-9 >60s 1346 >60s 0 0 0.0 16.6 1.1 6 P-10 >60s 1342 >60s 0 0 0.0 18.7 0.7 6 P-11 >60s 1331 >60s 0 0 0.0 15.7 2.2 6 P-12 >60s 1308 >60s 0 0 0.0 19.0 0.1 6 P-13 >60s 1356 >60s 0 0 0.0 7.9 7.6 6 Airport Structures >60s 1400 >60s 0 0 0.0 17.3 0.0 6 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. igned� by: EJ V i wu� ,Kj. ,, ... SIGNATURE Staff Environmental Technician TITLE DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CD096 ATTACHMENT 2 HISTORICAL PERIMETER MONITORING PROBE TRENDS DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 This page intentionally left blank. DocuSign Envelope ID: 68530920-55A4-4CE7-9054-OF25970CDO96 SMITH GARDNER % CH4 by Volume 80.0 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0.0 MRV% WAACAYMOU Ci N N N N211N N N211 By: DJP Date: 6/20/2022 P1 Wei I P3 P7