9209_Wake_NorthWake_Unlined_MSWLF_March22GW_FID1684572_20220616
North Wake Unlined Landfill Facility \Permit No. 9209-MSWLF-1984 Semi -Annual -Groundwater Sampling Report March 2022 Sampling Event) Wake County Prepared June 2022 i WAKE COUNTY NORTH CAROLI NA Division of Waste Management -Solid Waste Reporting Form Notice: This none and any cox m inwn n try hedany e Ram Rubric u e t a eral St in NC Gene32-6). Statute 132-1. As such, these doamenb are available for inspection and examination by any person upon request INC(NC General Statute 132-6). Instructions: Prepare one form for each Individually monitored unit. Passe type or print legibly. Attach a notificelion table with values that attain or exceetl NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off --site source, pre-exisfing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporling limits. Attach a notification table of any methane gas values that affair or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(1). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit NCDENR-0WM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Consultant - CDM Smith Inc. Contact for questions about data formatting. Include data preparer's name, telephone number and E-mall address: Name: Mathew F. Colima Phone: (919) 3253500 E-mail: mlonemf%cdmsmith.cem NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Perrn0# (.0500&.1600) October 2044, 20061 ake County - North ponie Drive SWLF- .1600 March 26-31, 2022 Closed! Unl ned Landfill27615Wake Ralei9 8 Nonh Camlina iS Environmental Status: (Check all that apply) ❑ Indie/Background Monitoring © Detection Monitoring © Assessment Monitonng X❑ Corrective Action of data roustabout: (Check all that apply) Groundwater mongering data from monitoring wells Methane gas monitonng data Groundwater monitoring data from private water supply wells Corrective action data (specify) MNA Sampling Results Leachate monitoring data Oiher(sperily) Notification attached? ®No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and Preliminary analysis of the muse and significance of any concentration. ❑ Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitong points, rates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal antl attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the muse and significance of concentraMms exceeding groundwater standards. 1 am aware that there are significant penalties for making any false statement, representation, or "A fication including the possibility of a fine and imprisonment. Mathew F. Colons Consultant 919 325-3500 Facil' rese fa' a ame(Print) Title (Area Cod-012 e) Td,,Pho"e. 16 June 2022 Affix eat signature Date 5400 Glenwood Avenue, Suite 400. Raleigh, North Carolina 27612 y l Facility Representative Address s F-0412 NC PE Film License Number (if applicable effective May 1. 2009) , �(U 'Lp2'L Revised 6/2009 V Smith 5400 Glenwood Avenue, Suite 400 Raleigh, North Carolina 27612 tel: 919 325-3500 fax: 919 781-5730 June 16, 2022 Ms. Jaclynne Drummond North Carolina Department of Environmental Quality Division of Waste Management Solid Waste Section 2090 U.S. 70 Highway Swannanoa, North Carolina 28778 Subject: March 2022 Semi -Annual Groundwater Sampling Report North Wake Closed Unlined Landfill Facility Permit No. 9209-MSWLF-1984 Dear Ms. Drummond: CDM Smith Inc. (CDM Smith), on behalf of Wake County (County), is submitting an electronic copy of the March 2022 semi-annual sampling event report. This letter report presents the results of the semi-annual sampling event that was recently completed at the North Wake Closed Unlined Landfill (Site) and constitutes the first semi-annual sampling event for 2022. The groundwater monitoring network consists of the following wells: MW-11 (shallow background well), -11d (deep background well), -5R, -6, -6d, -7, -8, -8d, -9, -10, -10d, -22, -23, -23d, -24, -28, -28d, -29d, -30, -31, -31d, -32, -33, -34, -34d, -35, -36, -36d, TB-1a and TB-1a deep. Surface water sampling locations include SW-2, -3, -7, and -8. Field activities, sampling results for all wells and surface water locations, an evaluation of the groundwater corrective action effectiveness, and recommendations are discussed below. Field Activities Groundwater and surface water samples from the Site were collected on March 28-31, 2022, except for MW-30 and TB-1a, which were dry during the March 2022 sampling event. Monitoring well and surface water sample locations are shown on Figure 1. Construction details for each monitoring well are summarized in Table 1. Samples were collected from the monitoring wells by use of a peristaltic pump or disposable, laboratory decontaminated bailers. Groundwater elevations were measured at each well on March 28, 2022, prior to sampling using an electronic water level indicator with an accuracy of 0.01 feet and are presented in Table 1. These groundwater elevations were used to construct potentiometric contours for this sampling event and are shown on Figure 1. The groundwater elevations and potentiometric contours were also used to estimate groundwater velocities at each well as presented in Table 2. Of WATER + ENVIRONMENT +TRANSPORTATION + ENERGY + FACILITIES Smith Ms. Jaclynne Drummond June 16, 2022 Page 2 After depth to groundwater was measured, three well volumes of water were removed from each well prior to sampling to provide fresh formation water within the well water column. Each well volume and surface water sample were measured for pH, conductivity, temperature, turbidity, dissolved oxygen (DO), and oxidation-reduction potential (ORP) using a YSI-556 multi -parameter water quality meter and a HANNA HI 98703 turbidity meter. Wells that had elevated turbidity (i.e., greater than 10 Nephelometric Turbidity Units) were allowed to stabilize prior to sample collection. No water quality parameters were measured in monitoring well MW-24, except for turbidity, due to an insufficient volume of water in the well. MW-24 was purged dry prior to evacuating one well volume and was allowed to recharge overnight before sample collection. The water quality measurements at the time of sample collection are provided in Table 3. Alternate Source Demonstration On August 17, 2020, CDM Smith submitted an Alternate Source Demonstration (ASD) for the Site on behalf of the County. The purpose of the ASD was to demonstrate that metals exceeding the 15A NCAC 02L .0202 (NC 2L) Groundwater Standards or Interim Maximum Allowable Concentrations (IMAC) are naturally occurring and not related to a release from the landfill. The ASD was prepared using analytical data from the background monitoring wells, MW-11 and -11D, that was collected on a quarterly basis from January 2018 to April 2020 to develop upper tolerance limits (UTLs) for specific analytes that historically exceeded their respective NC 2L Groundwater Standard or IMAC. Based on statistical analysis, a UTL of 6 parts per billion (ppb) was proposed for cobalt and a UTL of 23 ppb was proposed for vanadium. The North Carolina Department of Environmental Quality's (NCDEQ) Solid Waste Section (SWS) approved these proposed UTLs on August 17, 2020. Sampling Results All groundwater and surface water samples were analyzed by Pace Analytical Services, LLC located in West Columbia, South Carolina, for North Carolina Appendix I volatile organic compounds (VOCs) plus dichlorodifluoromethane and Appendix I metals plus mercury. Samples from monitoring wells MW-5R, -6, -8, -9, -10, -11, -34, -34d, and -36 were also analyzed for natural attenuation parameters (i.e., biochemical oxygen demand (BOD), chemical oxygen demand, alkalinity, nitrate, chloride, sulfate, sulfide, total organic carbon, carbon dioxide, methane, ethane, ethene, ferrous iron, volatile fatty acids, and dissolved hydrogen) per the Corrective Action Plan (CAP) and CAP Addendum that were approved by the SWS in March 2010 and on June 10, 2019, respectively. Monitoring wells MW-5R, -34, and -34d were also analyzed for total iron, sodium, and total dissolved solids. The CAP and CAP Addendum are discussed below. In a letter dated May 29, 2018, the SWS stated that all groundwater and surface water samples collected from landfills be analyzed for 1,4-dioxane after July 1, 2018. On June 26, 2019, the SWS approved the removal of 1,4-dioxane from the sampling program for all monitoring wells and surface water locations, with the exceptions of MW-6, -8, and -9, due to two non -detect events (October 2018 0 Smith Ms. Jaclynne Drummond June 16, 2022 Page 3 and April 2019). Samples were collected from the wells requiring the 1,4-dioxane analysis during the March 2022 sampling event. Sample results are provided below. The analytical results were reported to the laboratory specific method detection limit (MDL) and are quantifiable at or below the laboratory limit of quantitation (LOQ). All monitoring wells for the Site had detections of analytes above the MDL but below the LOQ that were qualified as estimated or "J" flags. The following list summarizes which analytes were detected above the LOQ at each sample location. Underlined analytes exceeded the NC 2L Groundwater Standard or UTL. There were no detections in the surface water samples that exceeded the 15A NCAC 02B (NC 2B) or North Carolina In -Stream Target Value Surface Water Quality Standard for Class C Waters. No "J" flag detections are listed. A complete summary of all detected and estimated concentrations from the April 2012 through the March 2022 sampling events is presented in Table 4. Laboratory data reports are provided in Appendix A. MW-11 (Shallow Background) Metals: Volatile Organic Compounds: MW-11d (Deep Background) Metals: Volatile Organic Compounds: MW-SR Metals: Volatile Organic Compounds MW-6 Metals: Volatile Organic Compounds MW-6d Metals: Volatile Organic Compounds MW-7 Metals: Volatile Organic Compounds: Barium None Detected Barium None Detected Barium, Cobalt, Nickel None Detected Barium, Cobalt, Nickel 1,4-Dichlorobenzene, 1,1-Dichloroethane, 1,4-Dioxane Barium Chloroform, Dichlorodifluoromethane, 1,1-Dichloroethane, cis-1,2-Dichloroethene, Methylene Chloride Barium, Cobalt, Nickel Benzene, Chl0robenzene, 1,4-Dichlorobenzene tD Smith Ms. Jaclynne Drummond June 16, 2022 Page 4 MW-8 Metals: Barium, Cobalt, Nickel Volatile Organic Compounds: Benzene, Chl0robenzene, 1,4-Dichlorobenzene, cis- 1,2-Dichloroethene, 1,4-Dioxane MW-8d Metals: Barium Volatile Organic Compounds: None Detected MW-9 Metals: Barium, Cadmium, Copper, Lead, Nickel, Vanadium, Zinc Volatile Organic Compounds: Chloroethane, 1,4-Dichlorobenzene, 1,1-Dichloroethane, cis- 1,2-Dichloroethene, 1,4-Dioxane, Vinyl Chloride MW-10 Metals: Barium, Cadmium, Copper, Zinc Volatile Organic Compounds: 1,4-Dichlorobenzene, cis-1,2-Dichloroethene, Trichloroethene MW-10d Metals: Barium, Cadmium, Copper, Zinc Volatile Organic Compounds: 1,1-Dichloroethane M W-22 Metals: Barium, Cobalt, Nickel Volatile Organic Compounds: None Detected MW-23 Metals: Barium Volatile Organic Compounds: None Detected MW-23d Metals: Barium Volatile Organic Compounds: None Detected M W-24 Metals: Barium Volatile Organic Compounds: Chloroform MW-28 Metals: Barium, Chromium, Vanadium, Zinc Volatile Organic Compounds: None Detected iD Smith Ms. Jaclynne Drummond June 16, 2022 Page 5 MW-28d Metals: Barium, Copper, Lead, Vanadium, Zinc Volatile Organic Compounds: None Detected MW-29d Metals: Barium, Copper, Lead, Zinc Volatile Organic Compounds: None Detected MW-30 Metals: Dry Volatile Organic Compounds: Dry MW-31 Metals: Barium Volatile Organic Compounds: None Detected MW-31 d Metals: Barium, Chromium, Copper, Vanadium, Zinc Volatile Organic Compounds: Chloroform MW-32 Metals: Barium, Beryllium, Vanadium Volatile Organic Compounds: Chloroform TB-1 a Metals: Dry Volatile Organic Compounds: Dry TB-1a deep Metals: Barium, Zinc Volatile Organic Compounds: None Detected MW-33 Metals: Barium Volatile Organic Compounds: None Detected 0 Smith Ms. Jaclynne Drummond June 16, 2022 Page 6 MW-34 Metals: Barium Volatile Organic Compounds: Benzene, Chloroform, 1,4-Dichlorobenzene, Dichlorodifluoromethane, 1,1-Dichloroethane, cis- 1,2-Dichloroethene, Methylene Chloride, Tetrachloroethene, Trichloroethene, Trichlorofluoromethane MW-34d Metals: Barium, Chromium Volatile Organic Compounds: 1,1-Dichloroethane, cis-1,2-Dichloroethene MW-35 Metals: Barium, Beryllium, Zinc Volatile Organic Compounds: Dichlorodifluoromethane, 1,1-Dichloroethane, Tetra chloroethene, Trichloroethene, Trichlorofluoromethane MW-36 Metals: Barium Volatile Organic Compounds: 1,1-Dichloroethane, cis- 1,2-Dichloroethene, Vinyl Chloride MW-36d Metals: Barium, Copper, Zinc Volatile Organic Compounds: 1,4-Dichlorobenzene, 1,1-Dichloroethane, cis-1,2-Dichloroethene SW-2 Metals: Barium Volatile Organic Compounds: None Detected SW-3 Metals: Barium Volatile Organic Compounds: None Detected SW-7 Metals: Barium Volatile Organic Compounds: None Detected SW-8 Metals: Barium Volatile Organic Compounds: None Detected 0 Smith Ms. Jaclynne Drummond June 16, 2022 Page 7 "J" flags were not included in the previous list, but samples collected from MW-34 and -36 had "J" flag detections of chromium that exceeded its NC 2L Groundwater Standard. Samples collected from MW-8 and -9 also had "J" flag detections of vinyl chloride and 1,2-dichloroethane, respectively, that exceeded their NC 2L Groundwater Standards. Additionally, it is likely that the recent and historic detections of chloroform in wells MW-6d, -24, -31, -31d, -32, TB-1a, and -1a deep are attributed to a release from a municipal water line in the Falls River development and are not related to a release from the Site. In a letter dated March 22, 2012, the SWS approved the County's request to discontinue collecting samples from select wells for herbicide and pesticide analyses during the semi-annual spring sampling event. However, the SWS requested that MW-29d continue to be sampled for bis(2-ethylhexyl) phthalate during spring sampling events due to a detection from the March 2011 event. Bis(2-ethylhexyl) phthalate was detected above the NC 2L Groundwater Standard (3 parts per billion (ppb)) at 28.5 ppb in samples collected from MW-29d during the April 2014 sampling event. A confirmatory sample collected from MW-29d during the November 2014 sampling event had an estimated detection of bis(2-ethylhexyl) phthalate at 4.61 ppb, which is above the standard. Bis(2- ethylhexyl) phthalate has not been detected above the laboratory MDL in samples collected from MW-29d since the November 2014 sampling event, except for estimated detections below the NC 2L Groundwater Standard in samples collected during the 2018, April 2020, and March 2022 events. The concentration trend for bis(2-ethylhexyl) phthalate in MW-29d will continue to be evaluated. An equipment and two trip blanks were analyzed for quality control. A duplicate sample was also collected for quality control. There were no detections in the equipment or trip blanks above the MDLs. The duplicate sample, identified as DUP, was collected from MW-23d, and had similar analyte concentrations as those detected in MW-23d, except for estimated detections of copper and selenium in the parent sample below their respective NC 2L Groundwater Standards. Table 5 presents a summary of all analytes detected during the March 2022 sampling event that exceeded the NC 2L Groundwater Standards or UTLs. Corrective Action via Air Sparging The SWS expressed concern in May 2008 that VOCs may be migrating beyond the Site property boundary and into Abbott's Creek based on detections above the NC 2L Groundwater Standard in monitoring well MW-9. As a result, the SWS directed the County to install and sample groundwater monitoring wells, one shallow and one deep (i.e., MW-36 and -36d), downgradient of MW-9 to determine if VOCs may be migrating beyond the Site property boundary, possibly discharging into Abbott's Creek. Initial groundwater samples collected from MW-36 and -36d in December 2008 had detections of VOCs above NC 2L Groundwater Standards. 0 Smith Ms. Jaclynne Drummond June 16, 2022 Page 8 Surface water sample locations SW-7 and -8, located on Abbott's Creek, were added to the semi- annual monitoring program in November 2008. Samples collected from SW-7 and -8 since being added to the monitoring program have never had VOCs detected above the NC 2B Surface Water Quality Standards. An Assessment of Corrective Measures Report was submitted to the SWS in accordance with the North Carolina Solid Waste Management Rule 15 NCAC 13B .1635 and approved in December 2009. The SWS approved the selected remedy of monitored natural attenuation paired with in situ remediation by air sparging to address groundwater contamination at the facility. A pilot test was conducted in July and August 2010 near MW-6 and -6d to evaluate the effectiveness of the air sparging remedy and to collect data for the full-scale system design in accordance with the CAP. The pilot test successfully reduced the concentrations of 1,1-dichloroethane and vinyl chloride to below their respective NC 2L Groundwater Standard in MW-6d and vinyl chloride was not detected in samples collected from MW-6 during the October 2010 semi-annual sampling event. The full-scale system was installed in October 2011 and was operational in August 2012. The air sparging system consists of 15 shallow wells screened across saturated saprolite and partially weathered rock and 14 wells screened in the shallow fractured bedrock. In addition to the air sparging wells, the system also consists of an air compressor and control panel that are housed in a secured on -site control building. Routine inspections are performed on the system and a Field Inspection Log completed during each inspection is kept on file at the facility. The County installed a vacuum extraction system around the perimeter of the Site in January 2002 to prevent offsite migration of soil gas. The air sparging system was designed to work in tandem with the existing perimeter migration control system (PMCS) by recovering air and gas vapors produced by the air sparging system. Since previous work has indicated a relationship between the soil gas and the contaminated groundwater, the installation of the PMCS is likely to further reduce groundwater contaminant concentrations. As discussed in the approved CAP, the vacuum extraction system will be used in conjunction with the air sparging system to reduce VOCs in the bedrock and partially weathered rock between MW-9 and the MW-6 nested pair. As part of the corrective action effectiveness evaluation, contaminant concentration trends for monitoring wells MW-6, -6d, -9, -36, and -36d were evaluated. Total VOC concentration trends for each well are presented on Figures 2 through 6. Trend results for each well are discussed below. Figure 2 presents a total VOC concentration trend analysis for samples collected from MW-6. VOCs in MW-6 significantly decreased after January 2002 when the PMCS was operational and were not detected from November 2004 to April 2007. The total VOC concentration in MW-6 increased in May 2008 to 24 ppb compared to the November 2007 concentration of 14 ppb. The total VOC concentration in MW-6 showed a decreasing trend from May 2008 to April 2018 but has increased iD Smith Ms. Jaclynne Drummond June 16, 2022 Page 9 since the introduction of the 1,4-dioxane analysis in October 2018. The total VOC concentration in MW-6 has fluctuated since October 2018. Vinyl chloride has not been detected above the laboratory MDL in MW-6 since the April 2013 sampling event. Benzene detections in MW-6, which historically have exceeded the NC 2L Groundwater Standard, have been below the laboratory MDL since April 2013 except for the November 2014 sampling event when it was detected slightly above the standard at 1.1 ppb and October 2018 when it was detected above the MDL at 0.61 ppb. The trend analysis for total VOC concentrations in MW-6d is presented on Figure 3. VOCs were not detected at MW-6d from December 2001 through November 2007. The increase in total VOCs from samples collected during the May 2008 sampling event is a result of reporting "J" flag detections as required by the SWS. VOC concentrations in MW-6d have been below the NC 2L Groundwater Standards since the March 2011 sampling event and but show an increasing trend. Figure 4 presents a total VOC concentration trend analysis for samples collected from MW-9. Historically, MW-9 has had the highest concentration of VOCs compared to the other monitoring wells. VOCs were not detected above the NC 2L Groundwater Standards in MW-9 from October 2012 through April 2015. Benzene, 1,4-dichlorobenzene, 1,2-dichloroethane, 1,4-dioxane, and vinyl chloride have recently been detected above their respective NC 2L Groundwater Standards in MW-9. The total VOC concentration trend has been slightly increasing at MW-9 since the October 2018 sampling event. Trend analyses for total VOC concentrations in MW-36 and -36d are presented on Figures 5 and 6, respectively. Vinyl Chloride was detected above its NC 2L Groundwater Standard during the October 2020 sampling event for the first time in samples collected from MW-36 since March 2011, and was also detected above the standard during the November 2021 and March 2022 sampling events. However, total VOC concentrations have shown a decreasing trend since the air sparging system has been operational. No VOCs have been detected above the NC 2L Groundwater Standards in MW-36d since the October 2015 sampling event. Total VOC concentrations in both monitoring wells will continue to be monitored and are expected to decrease while the air sparging system is operational. Additional groundwater samples were collected from MW-5R, -6, -8, -9, -10, -11, and -36 for evaluation of monitored natural attenuation parameters as part of the corrective action program as required by SWS guidelines. Geochemical results are presented in Table 6. The laboratory data for the additional parameters is included in Appendix A. As discussed in the approved CAP, concentrations of some of the natural attenuation data from select wells indicates that environments are present which favor reductive dechlorination; notably, the concentrations of nitrate, ferrous iron, sulfate, and carbon dioxide. The following evidence indicates tD Smith Ms. Jaclynne Drummond June 16, 2022 Page 10 that one or more mechanisms of natural attenuation and/or reductive dechlorination may be occurring at the site: • VOC concentrations in contaminated wells continue to decline; • The ratio of parent to daughter compounds continues to decrease over time; • Nitrate, ferrous iron, sulfate, and carbon dioxide continue to be detected at concentrations favoring reductive dechlorination; and • Concentrations of cis-1,2-dichloroethene continue to be greater than dichloroethene isomers trans-1,2-dichloroethene and 1,1-dichloroethene. Corrective Action via In Situ Bioremediation Injection VOCs that exceed the NC 2L Groundwater Standards, including benzene, 1,4-dichlorobenzene, 1,1-dichloroethane, methylene chloride, tetrachloroethene (PCE), trichloroethene (TCE), and vinyl chloride, have been detected in the area of MW-51R, -34, and -34d. MW-5R is located near the Site property line and the MW-34 cluster is located east of MW-5R on the adjacent parcel, more than 900 feet from the air sparging system. The VOC exceedances are likely from the migration of leachate from the Site into the surficial aquifer. In accordance with the CAP Addendum that was approved by the SWS on July 10, 2019, and an injection permit obtained from the Division of Water Quality — Underground Injection Control Program on July 24, 2019, an in situ enhanced anaerobic bioremediation (EAB) injection was completed by adding sodium lactate and emulsified vegetable oil (EVO) substrates through a biobarrier injection system to reduce total VOC concentrations at the property line. Sodium lactate and EVO enhance biologically reducing conditions that favor and support dechlorination of VOCs to non -toxic end products. On August 26-28, 2019, eight injection wells (i.e., NWIW-1 through -8) were installed upgradient of MW-5R, -35, and -34d, as shown on Figure 1. An initial injection of sodium lactate was completed from October 8-16, 2019. A total of 54,181 gallons of a 2.4 percent sodium lactate solution were injected. Post -sodium lactate injection samples were collected 1 month after the injection during the November 2019 semi-annual sampling event. Samples collected from monitoring wells MW-5R, -34, and -34d were analyzed for natural attenuation parameters, sodium, total iron, and total dissolved solids. Analytical results are summarized in Tables 4 and 6. The EVO injection was completed on November 18-30 and December 1-6, 2019, with a 3.3 percent solution of 98 percent LactOil° EVO formulation. A total of 80,751 gallons of the solution was injected. The effectiveness of the EAB injection was evaluated with quarterly sampling of MW-51R, -34, and -34d on February 4, April 8, July 30, and October 15, 2020. A report summarizing the results of the EAB injection was submitted to the SWS on June 23, 2021. Chlorinated VOC data were reviewed to 0 Smith Ms. Jaclynne Drummond June 16, 2022 Page 11 evaluate concentration trends over time and to determine if dechlorination is occurring. Total VOC concentration trends for each well are presented on Figures 7 through 9. Trend results for each well are discussed below. The VOC trend analysis for MW-5R is presented on Figure 7. TCE has never been detected above the NC 2L Groundwater Standard in MW-5R and PCE has never been detected above the MDL, except during the April 2019 sampling event when PCE was detected as an estimated concentration below the standard. Vinyl chloride was the most recent analyte detected above the NC 2L Groundwater Standard (April 2019). The geochemical data indicates reducing conditions to support anaerobic dechlorination at MW-5R, shown by decreasing levels of sulfate, nitrate, DO, and negative values of ORP. Additionally, total VOC concentrations show a decreasing trend since the injection events. The trend analyses for MW-34 and -34d are presented on Figures 8 and 9, respectively. Since the injections, total VOC, PCE, TCE, and 1,1-dichloroethane concentrations have fluctuated. Concentrations of methylene chloride show a decreasing trend and cis-1,2-dichloroethene concentrations have fluctuated in MW-34. Total VOC concentrations in MW-34d have decreased as the reducing conditions at the upgradient biobarrier support dechlorination. Recommendations The County will continue with the semi-annual assessment monitoring program. In addition to sampling for Appendix I metals plus mercury, Appendix I VOCs plus dichlorodifluoromethane, and the Appendix 11 constituent, bis(2-ethylhexyl) phthalate (sampled at MW-29d only during the spring sampling event), samples collected from MW-5R, -6, -8, -9, -10, -11, -34, -34d, and -36 will continue to be analyzed for natural attenuation parameters during the semi-annual events. MW-6, -8, and -9 will continue to be analyzed for 1,4-dioxane. The air sparging system will continue to operate and the effectiveness of the system will be re-evaluated after the next semi-annual sampling event in the fall of 2022. If you have any questions or require further explanation, do not hesitate to call me at (919) 325-3500. Sincerely, %&I� Mathew F. Colone, P.G. CDM Smith Inc. cc: John Roberson, WCSWM Elliott Cornell, WCSWM 0 Table 1 Monitoring Well Construction Summary and Groundwater Elevations March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 .. DepthsFacility Permit Monitoring Completion Screened Total Depth I I I TOC) Casing I In terva I Interval Interval (inches) Elevation Groundwater Elevation Number Well Code Date Lattitude Longitude Lithology (feet below Screen Filter Sea I 9209-MSWLF-1984 MW-5R 1/30/2004 35.91192 78.57159 Regolith 27.5 10.0-25.0 8.0-25.0 6.0-8.0 2 225.28 15.60 209.68 9209-MSWLF-1984 MW-6 March-94 35.91423 78.57122 Regolith 22.0 -- 10.0-20.0 8.0-20.0 6.0-8.0 2 219.80 12.50 207.30 9209-MSWLF-1984 MW-6d 5/1/2001 35.91423 78.57122 Bedrock 65.0 0-45.0 52.0-62.0 50.0-62.0 48.0-50.0 2 218.61 12.75 205.86 9209-MSWLF-1984 MW-7 March-94 35.91098 78.57436 Regolith 21.5 9.0-19.0 7.0-19.0 5.0-7.0 2 234.15 12.43 221.72 9209-MSWLF-1984 MW-8 March-94 35.91078 78.57266 Regolith 21.5 -- 9.0-19.0 7.0-19.0 5.0-7.0 2 226.38 11.49 214.89 9209-MSWLF-1984 MW-8d 5/3/2001 35.91078 78.57266 Bedrock 45.0 0-30.0 37.0-42.0 35.0-42.0 29.0-35.0 2 226.16 12.54 213.62 9209-MSWLF-1984 MW-9 March-94 35.91484 78.57273 Regolith 44.0 -- 32.0-42.0 30.0-42.0 28.0-30.0 2 242.69 30.25 212.44 9209-MSWLF-1984 MW-10 4/1/1998 35.91499 78.57494 Bedrock 55.5 43.0-53.0 41.0-53.0 39.0-41.0 2 274.76 44.35 230.41 9209-MSWLF-1984 MW-10d 5/1/2001 35.91499 78.57494 Bedrock 93.0 80.0-90.0 78.0-92.0 75.0-78.0 2 274.54 47.75 226.79 9209-MSWLF-1984 MW-11 October-95 35.90574 78.58251 Regolith 57.0 39.0-54.0 37.0-54.0 35.0-37.0 2 343.63 43.51 300.12 9209-MSWLF-1984 MW-11d October-95 35.90578 78.58248 Bedrock 72.0 64.0-69.0 62.0-69.0 60.0-62.0 2 343.27 43.70 299.57 9209-MSWLF-1984 MW-22 June-97 35.91596 78.57453 Regolith 39.0 27.0-37.0 25.0-37.0 23.0-25.0 2 254.62 35.45 219.17 9209-MSWLF-1984 MW-23 June-97 35.91373 78.57540 Regolith 50.0 38.0-48.0 36.0-48.0 34.0-36.0 2 274.83 45.71 229.12 9209-MSWLF-1984 MW-23d 4/27/1998 35.91373 78.57540 Bedrock 91.0 0-43.0 78.0-88.0 76.0-88.0 74.0-76.0 2 274.89 45.70 229.19 9209-MSWLF-1984 MW-24 June-97 35.91232 78.57546 Regolith 47.5 35.0-45.0 33.0-45.0 31.0-33.0 2 266.64 45.60 221.04 9209-MSWLF-1984 MW-28 4/9/1998 35.91644 78.57439 Regolith 30.0 -- 20.0-30.0 18.0-30.0 16.0-18.0 2 237.89 18.67 219.22 9209-MSWLF-1984 MW-28d 4/22/1998 35.91644 78.57439 Bedrock 51.0 0-28.0 41.0-51.0 39.0-51.0 37.0-39.0 2 238.44 18.61 219.83 9209-MSWLF-1984 MW-29d 4/22/1998 35.91472 78.57572 Bedrock 52.0 0-40.5 47.0-52.0 45.0-52.0 43.0-45.0 2 275.06 42.35 232.71 9209-MSWLF-1984 MW-30 4/14/1998 35.91374 78.57596 Regolith 55.0 40.0-55.0 38.0-55.0 36.0-38.0 2 282.32 51.51 230.81 9209-MSWLF-1984 MW-31 4/2/1998 35.91231 78.57595 Regolith 35.5 -- 25.5-35.5 23.0-35.5 21.0-23.0 2 261.67 32.82 228.85 9209-MSWLF-1984 MW-31d 4/23/1998 35.91231 78.57595 Bedrock 66.0 0-51.0 56.0-66.0 54.0-66.0 52.0-54.0 2 260.92 32.26 228.66 9209-MSWLF-1984 MW-32 4/3/1998 35.91142 78.57564 Regolith 26.0 13.0-23.0 11.0-23.0 9.0-11.0 2 242.99 16.05 226.94 9209-MSWLF-1984 TB-1a 4/7/1998 35.91188 78.57595 Regolith 30.0 -- 20.0-30.0 17.5-30.0 14.0-17.5 2 255.05 28.15 226.90 9209-MSWLF-1984 TB-1a deep 5/7/2001 35.91188 78.57595 Bedrock 62.0 0-23.0 52.0-62.0 50.0-62.0 47.0-50.0 2 256.01 30.35 225.66 9209-MSWLF-1984 MW-33 7/22/1998 35.91077 78.57169 Regolith 28.0 10.0-25.0 8.0-25.0 6.0-8.0 2 222.01 11.22 210.79 9209-MSWLF-1984 MW-34 7/23/1998 35.91192 78.57116 Regolith 28.0 -- 15.0-25.0 13.0-25.0 11.013.0 2 221.96 13.09 208.87 9209-MSWLF-1984 MW-34d 7/23/1998 35.91192 78.57116 Bedrock 58.0 0-38.0 45.0-55.0 43.0-55.0 41.0-43.0 2 222.16 13.50 208.66 9209-MSWLF-1984 MW-35 7/23/1998 35.91322 78.57052 Regolith 28.0 10.0-25.0 8.0-25.0 6.0-8.0 2 223.48 16.25 207.23 9209-MSWLF-1984 MW-36 11/25/2008 35.91491 78.57193 Regolith 40.0 -- 25.0-40.0 23.0-40.0 21.0-23.0 2 237.40 26.75 210.65 9209-MSWLF-1984 MW-36cl 1 11/25/2008 1 35.91491 78.57193 1 Bedrock 1 55.0 1 0-45.0 50.0-55.0 48.0-55.0 45.0-48.0 2 1 237.68 27.00 210.68 Notes: 1. TOC - Top of Casing 2. bgs - Below Ground Surface 3. Latitude and Longitude Coordinates - World Geodetic System 1983 Smith Page 1 of 1 June 2022 Table 2 Summary of Calculated Groundwater Flow Velocities March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 E Average 9209-MSWLF-1984 MW-SRPS33 0.18 0.0233 4.28E-02 1 (feet/day) 0.0241 4.43E-02 0.0235 4.31E-02 0.0257 4.72E-02 0.0233 4.27E-02 E-04 9209-MSWLF-1984 MW-6 10.58 0.13 0.0206 1.68E+00 0.0209 1.70E+00 0.0208 1.69E+00 0.0206!!! 1.68E+00 0.0204 1.66E+00 3.73E-03 9209-MSWLF-1984 MW-7 1.15 0.18 0.0257 1.64E-01 0.0261 1.66E-01 0.0256 1.64E-01 0.0257 1.64E-01 0.0255 1.63E-01 4.06E-04 9209-MSWLF-1984 MW-8 3.61 0.18 0.0249 5.00E-01 0.0252 5.06E-01 0.0248 4.98E-01 0.0249 4.99E-01 0.0247 4.96E-01 1.27E-03 9209-MSWLF-1984 MW-9 1.22 0.30 0.0201 8.16E-02 0.0199 8.10E-02 0.0200 8.15E-02 0.0198 8.06E-02 0.0200 8.12E-02 4.30E-04 9209-MSWLF-1984 MW-10 0.509 0.05 0.0168 1.72E-01 0.0171 1.74E-01 0.0171 1.74E-01 0.0172 1.75E-01 0.0174 1.78E-01 1.80E-04 9209-MSWLF-1984 MW-11 5.66 0.13 0.0214 9.31E-01 0.0217 9.44E-01 0.0215 9.35E-01 0.0217 9.46E-01 0.0215 9.35E-01 2.00E-03 9209-MSWLF-1984 MW-22 0.07 0.18 0.0182 7.09E-03 0.0185 7.21E-03 0.0182 7.07E-03 0.0185 7.21E-03 0.0185 7.21E-03 2.47E-05 9209-MSWLF-1984 MW-23 3.59 0.30 0.0196 2.35E-01 0.0198 2.36E-01 0.0197 2.36E-01 0.0198 2.37E-01 0.0198 2.37E-01 1.27E-03 9209-MSWLF-1984 MW-24 0.34 0.30 0.0248 2.81E-02 0.0253 2.86E-02 0.0251 2.84E-02 0.0251 2.85E-02 0.0251 2.85E-02 1.20E-04 9209-MSWLF-1984 MW-36 17.56 0.30 0.0197 1.16E+00 0.0200 1.17E+00 0.0197 1.15E+00 0.0197 1.16E+00 0.0197 1.16E+00 6.19E-03 9209-MSWLF-1984 MW-36D 0.78 0.10 0.0196 1.53E-01 0.0199 1.55E-01 0.0195 1.52E-01 0.0196 1.53E-01 0.0196 1.53E-01 2.75E-04 1 1 1 Notes: 1. cm/s - centimeters per second 2. Hydraulic conductivity and effective porosity values are estimated from previously perfomed slug tests and grain size analyses. 3. The gradient and linear velocity values shown for MW-11 are based on the average of all the listed wells, with the exception of MW-36D. CDM Smith Page 1 of 3 June 2022 Table 2 Summary of Calculated Groundwater Flow Velocities March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 9209-MSWLF-1984 MW-5R 0.33 0.18 0.0233 4.27E-02 0.0229 4.20E-02 0.0238 4.36E-02 0.0233 4.27E-02 0.0236 r"4 33E-02 1.16E-04 9209-MSWLF-1984 MW-6 10.58 0.13 0.0203 1.65E+00 0.0204 1.66E+00 0.0206 1.67E+00 0.0205 1.66E+00 0.0206 1.68E+00 3.73E-03 9209-MSWLF-1984 MW-7 1.15 0.18 0.0253 1.62E-01 0.0256 1.64E-01 0.0257 1.64E-01 0.0256 1.63E-01 0.0257 1.64E-01 4.06E-04 9209-MSWLF-1984 MW-8 3.61 0.18 0.0245 4.92E-01 0.0249 4.98E-01 0.0249 4.99E-01 0.0248 4.98E-01 0.0250 5.01E-01 1.27E-03 9209-MSWLF-1984 MW-9 1.22 0.30 0.0198 8.06E-02 0.0199 8.10E-02 0.0201 8.18E-02 0.0200 8.13E-02 0.0202 8.20E-02 4.30E-04 9209-MSWLF-1984 MW-10 0.509 0.05 0.0173 1.76E-01 0.0169 1.72E-01 0.0170 1.73E-01 0.0169 1.72E-01 0.0171 1.74E-01 1.80E-04 9209-MSWLF-1984 MW-11 5.66 0.13 0.0213 9.28E-01 0.0213 9.27E-01 0.0215 9.36E-01 0.0214 9.30E-01 0.0215 9.37E-01 2.00E-03 9209-MSWLF-1984 MW-22 0.07 0.18 0.0183 7.12E-03 0.0181 7.04E-03 0.0184 7.16E-03 0.0183 7.11E-03 0.0184 7.17E-03 2.47E-05 9209-MSWLF-1984 MW-23 3.59 0.30 0.0199 2.38E-01 0.0197 2.36E-01 0.0197 2.36E-01 0.0197 2.35E-01 0.0198 2.37E-01 1.27E-03 9209-MSWLF-1984 MW-24 0.34 2.83E-02 0.0248 2.82E-02 0.0251 2.84E-02 0.0249 2.83E-02 0.0251 2.85E-02 1.20E-049209-MSWLF-1984 MW-36 17.560.0195 EO.300.0250 1.14E+00 0.0196 1.15E+00 0.0198 1.16E+00 0.0196 1.15E+00 0.0198 1.16E+00 6.19E-039209-MSWLF-1984 MW-36D 0.78 0.0194 1.51E-01 0.0195 1.52E-01 0.0043 3.35E-02 0.0195 1.52E-01 0.0197 1.53E-01 2.75E-04 1 Notes: 1. cm/s - centimeters per second 2. Hydraulic conductivity and effective porosity values are estimated from previously perfomed slug tests and grain size analyses. 3. The gradient and linear velocity values shown for MW-11 are based on the average of all the listed wells, with the exception of MW-36D. CDM Smith Page 2 of 3 June 2022 Table 2 Summary of Calculated Groundwater Flow Velocities March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 Average Linear Velocity Average Linear Velocity 9209-MSWLF-1984 MW-5R 0.33 0.18 (feet/day) (feet/day) FO.O232 0.0236 4.33E-02 0.0235 4.32E-02 4.26E-02 1.16E-04 9209-MSWLF-1984 MW-6 10.58 0.13 0.0206 1.68E+00 0.0205 1.67E+00 0.0204 1.66E+00 3.73E-03 9209-MSWLF-1984 MW-7 1.15 0.18 0.0257 1.64E-01 0.0256 1.63E-01 0.0256 1.63E-01 4.06E-04 9209-MSWLF-1984 MW-8 3.61 0.18 0.0250 5.01E-01 0.0248 4.97E-01 0.0248 4.97E-01 1.27E-03 9209-MSWLF-1984 MW-9 1.22 0.30 0.0202 8.20E-02 0.0200 8.12E-02 0.0200 8.12E-02 4.30E-04 9209-MSWLF-1984 MW-10 0.509 0.05 0.0171 1.74E-01 0.0168 1.71E-01 0.0172 1.75E-01 1.80E-04 9209-MSWLF-1984 MW-11 5.66 0.13 0.0215 9.37E-01 0.0214 9.30E-01 0.0214 9.32E-01 2.00E-03 9209-MSWLF-1984 MW-22 0.07 0.18 0.0184 7.16E-03 0.0183 7.13E-03 0.0184 7.15E-03 2.47E-05 9209-MSWLF-1984 MW-23 3.59 0.30 0.0198 2.37E-01 0.0194 2.32E-01 0.0198 2.37E-01 1.27E-03 9209-MSWLF-1984 MW-24 0.34 0.30 0.0251 2.85E-02 0.0251 2.84E-02 0.0250 2.83E-02 1.20E-04 9209-MSWLF-1984 MW-36 17.56 0.30 0.0198 1.16E+00 0.0196 1.15E+00 0.0196 1.15E+00 6.19E-03 9209-MSWLF-1984 MW-36D 0.78 0.10 0.0199 1.55E-01 0.0196 1.53E-01 0.0041 3.23E-02 2.75E-04 Notes: 1. cm/s - centimeters per second 2. Hydraulic conductivity and effective porosity values are estimated from previously perfomed slug tests and grain size analyses. 3. The gradient and linear velocity values shown for MW-11 are based on the average of all the listed wells, with the exception of MW-36D. CDM Smith Page 3 of 3 June 2022 Table 3 Water Quality Parameters March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill Permit Number 9209-MSWLF-1984 Water Quality Parameters Facility Permit Number 9209-MSWLF-1984 Monitoring Well Code MW-5R PH Conductivity Temperature Turbidity D. ... (S.U.) (VS/cm) (degrees Celsius) (NTUs) (mg/L) (mVs) 6.38 436 16.0 28 0.82 -42.3 9209-MSWLF-1984 MW-6 6.35 1,145 15.3 7 1.44 239.0 9209-MSWLF-1984 MW-6d 5.79 144 17.6 4 0.92 307.7 9209-MSWLF-1984 MW-7 6.00 686 18.5 5 0.11 -0.7 9209-MSWLF-1984 MW-8 6.03 503 15.9 9 2.36 51.1 9209-MSWLF-1984 MW-8d 5.85 171 16.9 4 0.89 150.4 9209-MSWLF-1984 MW-9 6.21 941 19.1 56 0.08 -4.4 9209-MSWLF-1984 MW-10 5.63 144 17.8 2 0.18 158.7 9209-MSWLF-1984 MW-10d 5.96 182 17.9 9 1.34 145.8 9209-MSWLF-1984 MW-11 5.69 93 17.3 9 4.71 257.8 9209-MSWLF-1984 MW-11d 5.67 109 17.6 9 5.14 216.4 9209-MSWLF-1984 MW-22 6.09 220 16.2 10 5.11 -28.6 9209-MSWLF-1984 MW-23 5.61 81 16.5 81 6.56 209.4 9209-MSWLF-1984 MW-23d 5.55 161 16.3 4 4.69 201.9 9209-MSWLF-1984 MW-24 NM NM NM 9 NM NM 9209-MSWLF-1984 MW-28 5.62 179 17.3 44 5.14 178.9 9209-MSWLF-1984 MW-28d 6.16 82 17.6 47 3.00 10.5 9209-MSWLF-1984 MW-29d 5.49 136 16.5 1 6 1 5.82 205.3 9209-MSWLF-1984 MW-30 Dry 9209-MSWLF-1984 MW-31 5.92 120 16.7 8 4.22 89.0 9209-MSWLF-1984 MW-31d 5.74 163 16.9 5 3.45 173.8 9209-MSWLF-1984 MW-32 4.64 84 15.3 33 4.50 221.3 9209-MSWLF-1984 TB-1a Dry 9209-MSWLF-1984 TB -la deep 5.45 176 16.2 9 2.01 212.1 9209-MSWLF-1984 MW-33 5.68 129 16.6 4 0.99 65.3 9209-MSWLF-1984 MW-34 5.15 147 14.7 126 0.20 200.4 9209-MSWLF-1984 MW-34d 5.73 234 15.3 5 1.48 220.2 9209-MSWLF-1984 MW-35 5.82 146 16.8 17 2.70 63.2 9209-MSWLF-1984 MW-36 5.68 213 16.6 131 0.43 112.7 9209-MSWLF-1984 9209-MSWLF-1984 MW-36d Surface Water Sample SW-2 6.05 7.45 289 136 16.6 13.7 10 9 0.08 8.34 1 29.4 225.4 9209-MSWLF-1984 SW-3 7.30 140 13.7 9 9.31 191.7 9209-MSWLF-1984 SW-7 6.68 108 13.1 7 11.11 171.0 9209-MSWLF-1984 SW-8 6.76 108 13.0 8 10.95 150.1 Notes: 1. Water quality measurements were collected on March 28-31, 2022. 2. NM - Not measured. MW-24 went dry before water quality parameters were measured. 3. Turbidity readings were recorded at the time samples were collected. 4. µS/cm - Microsiemens per centimeter 5. mg/L - Milligrams per liter 6. ORP - Oxidation -Reduction Potential 7. NTUs - Nephelometric Turbidity Units 8. mVs - Millivolts 9. S.U. - Standard Units 10. DO - Dissolved Oxygen GDM.. Smith Page 1 of 1 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 North Carolina 2Lor UTL 1 1 10 1 700 1 4 1 2 1 10 1 6- 11,0001 2.37.1 1S 1 1 1 100 1 20 1 20 1 2 1,00 1 23- J. 3.23J 12.1 MW-11 25-Apr-12 65.3.1 MW-11 23-Oct-12 80.6J 1.42J 3.66.1 5.32J 19.7 MW-11 17-Apr-13 90J 0.2.1 2.1 2.1 8.1 11 11 91 20B MW-11 16-Oct-13 100 0.1J 0.2.1 2.1 1J 4.1 0.5J 0.91 5J 15B MW-11 16-Apr-14 170 0.5J 0.2.1 4.1 6.1 18 1 3J 0.081 40 50B MW-11 12-Nov-14 90J 0.2.1 0.2.1 2.1 2J 8.1 11 11 0.05J 7J 24 MW-11 30-Apr-15 100 0.2J 2.1 3J 10J 11 2J 0.06J 12J 27 MW-11 15-Oct-15 110 0.3J 0.1J 3.1 3J 11 11 0.04J 2J 0.05J 13JB 27 MW-11 21-Apr-16 0.5J 130 0.3J 3.1 4J 16 2J 2J 0.1.113 18J 32 MW-11 1-Sep-16 90J 0.28.1 0.54.1 2.4.1 2.6J 8.3.1 1.3J 1.6J 111 20 MW-11 20-Apr-17 61.1 1.2.1 1.5J 11 MW-11 22-Sep-17 45J 2.4.1 1.8.1 3.7J 6.3.1 MW-11 13-Apr-18 61.1 2.3.1 2.0.1 0.27J 12 MW-11 25-Oct-18 71.1 2.2.1 3.9.1 0.50J 5.11 66 MW-11 (dissolved) 25-Oct-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-11 26-Feb-19 57J 2.0.1 1.4.1 10 MW-11 25-Apr-19 120 0.30J 3.8.1 3.3J 20 2.2J 1.81 17J 28 MW-11 (dissolved) 25-Apr-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-11 2-Jul-19 170 0.70 5.1 7.4 25 4.1 4.3J 33 45B MW-11 (dissolved) 2-Jul-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-11 7-Nov-19 59 2.1J 4.3.1 0.66J 0.48 5.6 25 MW-11 (dissolved) 7-Nov-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-11 22-Jan-20 87 0.27J 3.7.1 2.1J 12 1.9 1.5J 3.1 9.2 21 MW-11 (dissolved) 22-Jan-20 NA NA NA NA NA NA NA NA NA NA NA NA NA NA M W-11 9-Apr-20 55 2.3.1 7.3.1 M W-11 15-Oct-20 55 1.5.1 10 MW-11 31-Mar-21 52 2.3.1 2.6J 5.51 M W-11 11-Nov-21 47 5.51 MW-11 31-Mar-22 1 1 53 1 1 1.7.1 0.45.1 1 3.6J 7.91 MW-11d 26-Apr-12 0.247J 44.2.1 3.04J 9.68JB 3.31J 2.05J 4.621 MW-11d 24-Oct-12 43.7.1 0.375.1 2.40J 2.53J 5.101 MW-11d 18-Apr-13 0.4J 50J 0.1J 2J13 0.2.1 1J 0.6J 4.113 MW-11d 17-Oct-13 0.6J 0.61 50J 0.3.1 1.1 0.2.1 1J 0.02J 0.6J 2J 2.113 MW-11d 17-Apr-14 300 2.1 0.2J 15 13 56 11 91 0.2J 99 88 MW-11d 13-Nov-14 150 0.7J 0.1J 5.1 4J 18 4J 3J 0.07J 37 35 MW-11d 29-Apr-15 0.6J 0.5J 60J 0.1J 0.1J 2.1 0.6J 3.1 0.6J 0.91 51 8.1 MW-11d 15-Oct-15 0.4J 90J 0.3.1 0.1J 3.1 2J 9.1 2J 0.05J 2J 14JB 16 MW-11d 21-Apr-16 0.3J 60J 2.1 0.3.1 4.1 0.5J 2J 12 MW-11d 1-Sep-16 0.436J 45J 0.076J 1.2.1 2.1J 0.25J 0.75J 2.7J 9.2JB MW-11d 20-Apr-17 48J 2.2.1 2.2.1 2.2J 5.01 MW-11d 22-Sep-17 45J 2.8.1 1.6.1 3.3J 5.11 MW-11d 12-Apr-18 43J 5.8.1 2.8J 4.41 MW-11d 23-Oct-18 46J 25 13J 4.21 MW-11d 25-Feb-19 46J 7.0.1 3.4J 3.61 MW-11d (dup) 25-Feb-19 45J 9.91 4.9J 4.01 MW-11d 25-Apr-19 46J 5.01 2.2J 2.81 MW-11d 2-Jul-19 90 0.42 4.11 2.51 12 1.8 2.4J 17 18B MW-11d (dissolved) 2-Jul-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-11d 5-Nov-19 43 2.31 2.6J 0.29J 1.91 13B MW-11d (dup) 5-Nov-19 44 2.51 2.1J 0.26J 1.81 11B MW-11d 21-Jan-20 0.65J 46 2.81 2.1J 0.29J 8.41 MW-11d (dup) 21-Jan-20 0.86J 48 3.41 2.1J 0.37J 9.51 MW-11d 8-Apr-20 44 0.18J 5.3 1.3J 2.8J 9.91 MW-11d 13-Oct-20 0.84J 45 0.37J 3.0J 12 MW-11d 31-Mar-21 0.66J 46 0.40J 3.213J 4.6J 0.25J 1.4J 10 MW-11d 9-Nov-21 44 1.91 3.51 MW-11d 30-Mar-22 44 2.5J 1.71 3.41 Smith Page 1 of 30 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 24-Apr-12 0.411J 97.3J 2.79J 2.47J 0.170J 4.28J MW-513 MW-513 22-Oct-12 99.3J 1.82J 3.61J 0.114J 23.9 MW-513 17-Apr-13 80J 0.08J 2J 0.3J 3J 0.11 5JB MW-513 16-Oct-13 90J 0.05J 1J 0.5J 0.4J 3J 0.11 5JB MW-513 16-Apr-14 80J 0.3J 0.3J 0.2J 0.5J 1J 0.2J 2J 5JB MW-513 12-Nov-14 80J 2J 0.2J 2J 0.1 6JB MW-5R 30-Apr-15 70J 0.11 0.8J 0.11 11 0.11 4J MW-5R 15-Oct-15 110 0.2J 7J 0.8J 2J 0.6J 0.04J 4J 0.11 6J MW-5R 21-Apr-16 60J 0.07J 1J 0.2J 0.4J 1J 0.1JB 2J MW-5R 14-Sep-16 79J 0.063J 1.7J 0.45JB 0.046JB 2.4J 0.080J 1.1J 5.3JB MW-5R 20-Apr-17 71J 1.5J MW-5R 20-Sep-17 430 13 1.7J 1.4J 5.8J MW-5R 11-Apr-18 76J 1.4J 1.5J 2.6J MW-5R 24-Oct-18 84J 2.1J 3.3J MW-5R 22-Apr-19 68J 0.23J MW-5R 6-Nov-19 130 2.2J 2.3J 5.7 15 MW-5R 9-Apr-20 300 0.20J 0.13J 3.4J 290 2.9J 0.52J 100 0.51 4.3J 51 MW-5R (dissolved) 9-Apr-20 NA NA NA NA NA NA 390 NA NA NA 140 NA NA 0.32J NA MW-5R 15-Oct-20 1.3J 170 0.43 0.23J 18 93 8.3 3.4 18 1.1 0.18J 16 22 MW-5R (dissolved) 15-Oct-20 NA NA NA NA NA 91 NA NA NA NA NA NA NA NA NA MW-5R 31-Mar-21 64 0.15J 4.9J 75 1.5J 0.52J 12 2.7J 11 MW-5R 11-Nov-21 84 76 17 6.5J MW-5R 30-Mar-22 40 0.15J 39 1.9J 0.26J 7.9 4.3J MW-5R (dissolved) 30-Mar-22 NA NA NA NA NA NA 19 NA NA NA NA NA NA NA NA NA MW-6 24-Apr-12 0.244J 182 3.49J 54.9 8.45J 2.18J 0.134J 117 MW-6 22-Oct-12 258 0.148J 1.59J 80.4 15.1J MW-6 17-Apr-13 100J 0.05J 1.6 35 4J 0.17J 6J 0.1 9JB MW-6 16-Oct-13 90J 0.04J 0.3J 34 2J 0.02J 5J 2J 0.2J 3J 5JB MW-6 (dup) 16-Oct-13 901 0.2J 0.6J 35 2J 0.04J 6J 2J 0.2J 3J MW-6 16-Apr-14 0.2J 60J 0.10J 0.8J 11 18 3J 0.21 4J 0.1 2J 8JB MW-6 (dup) 16-Apr-14 60J 0.07J 0.7J 11 18 2J 0.21 4J 0.2J 3J 8JB MW-6 12-Nov-14 0.8J 310 49 11 0.02J 15J 2J 0.11 2JB MW-6 30-Apr-15 70J 0.06J 0.1J 25 11 0.08J 4J 0.11 3J MW-6 14-Oct-15 230 0.2J 32 4J 0.03J 13J 2J 0.1 MW-6 20-Apr-16 70J 0.04J 8J 0.5J 0.03J 3J 11 0.081 MW-6 (dup) 20-Apr-16 70J 0.3J 7J 0.6J 0.03J 3J 1J 0.07J MW-6 14-Sep-16 0.19JB 0.29J 210 0.13J 19 2.1JB 0.032JB 9.3J 1.1J 0.084J 1.2J 6.0JB MW-6 20-Apr-17 120 2.5J 8.3J 0.98J 0.40 4.2J MW-6 (dup) 20-Apr-17 130 2.6J 8.2J 1.0J 0.41 4.8J 21 MW-6 21-Sep-17 160 5.3J 2.2J 7.6J MW-6 12-Apr-18 130 0.14J 7.9J 4.6J MW-6 24-Oct-18 240 0.13J 1.3J 18 1.5J 6.9J MW-6 22-Apr-19 120 0.17J 0.13J 19 0.17J 4.5J MW-6 7-Nov-19 270 0.18J 67 1.6J 0.16BJ 18 2.5J 0.28J 6.4J MW-6 (dissolved) 7-Nov-19 NA NA NA NA NA NA 77 NA NA NA NA NA NA 0.32J NA NA MW-6 7-Apr-20 130 0.49 0.25J 8 20 5.5 1.6 0.19J 6.4 5.2 8.6J MW-6 15-Oct-20 160 0.14J 33 8.5 0.20J 2.6J MW-6 31-Mar-21 94 0.32J 0.17J 3.8J 23 2.3J 0.88J 0.19J 3.8J 3.8J 4.4J MW-6 (dissolved) 31-Mar-21 NA NA NA NA NA NA 25 NA NA NA NA NA NA NA NA NA MW-6 10-Nov-21 230 0.24J 9.0 2.2J 7.9 MW-6 29-Mar-22 220 0.17J 11 1 1.7J 0.14J 1 7.0 1 1.7J Smith Page 2 of 30 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 Ln 26-Apr-12 1.59J 72J 5.681 7.24JB 2.37J 2.61J 4J 6.97J MW-6d MW-6d (dup) 26-Apr-12 1.22J 66J 5.531 6.45JB 2.10J 2.20J 3.78J 5.881 MW-6d 23-Oct-12 1.21J 2.841 71.11 0.4071 4.831 2.831 2.11J 3.59J 6.021 MW-6d 18-Apr-13 3.1J 80J 0.11 0.51 41 0.91 31 0.4J 2J 816 MW-6d (dup) 18-Apr-13 2.8.1 70J 0.091 0.41 41 0.81 31 0.4J 2J 616 MW-6d 17-Oct-13 6.9 80J 0.11 0.51 41 11 41 0.6J 0.01 3J 1 716 MW-6d 17-Apr-14 1.2J 60J 0.11 0.11 41 1.01 21 0.3J 2J 6J 7.113 MW-6d 12-Nov-14 1.2J 60J 0.1J 0.21 31 11 21 0.3J 2J 416 MW-6d 30-Apr-15 1.7J 0.6J 50J 0.081 0.11 41 0.91 21 0.2J 2J 1 41 MW-6d (dup) 30-Apr-15 2.1J 80J 0.051 0.21 41 0.91 21 0.3J 0.05J 2J 1 6.113 MW-6d 15-Oct-15 1.1J 60J 0.1J 0.21 41 0.61 21 0.4J 0.04J 3J 2113 61 MW-6d 20-Apr-16 0.4J 50J 0.071 0.11 41 0.61 21 3J 41 MW-6d 12-Sep-16 1.0J 65J 0.211 4.41 0.851 6.6JB 1.7J 2.4J 0.34J 4.7J 15 MW-6d 20-Apr-17 511 2.61 2.41 1.6J 2.6J 9.11 MW-6d 22-Sep-17 0.661 33J 4.21 3.1J 4.1J 6.31 MW-6d 13-Apr-18 1.01 411 3.81 1.4J 7.61 MW-6d 24-Oct-18 311 7.91 2.4J 3.5J MW-6d 23-Apr-19 57J 0.151 8.21 5.31 0.51J 2.9J 8.2J 6.51 MW-6d 6-Nov-19 0.55J 70 0.81 4.41 3.51 0.39J 2.2J 3.5J 16 MW-6d 7-Apr-20 0.751 69 0.361 4.41 2.41 0.39J 1.91 9.51 MW-6d 13-Oct-20 2.8 130 0.251 3.41 1.51 0.33J 1.7J 19 MW-6d 31-Mar-21 0.781 85 0.171 4.21 2.1J 0.25J 1.6J 3.0J 8.51 MW-6d 10-Nov-21 32 0.161 0.201 3.21 0.097J 3.2J 2.51 MW-6d 29-Mar-22 27 3.71 1.31 1.7J 2.8J MW-7 26-Apr-12 50.31 0.805J 13.3 27.1 10.7E 4.04J 10.91 3.631 7.241 13.9 MW-7 22-Oct-12 80.71 29.6 30.8 37.4 6.69J 11.5J 2.021 0.152J 24.2J 24.1 MW-7 16-Apr-13 80J 0.51 0.6J 35 27 61 91 0.18J 13J 21 0.2J 24J 25B MW-7 16-Oct-13 60J 0.1J 0.6J 51 37 11 11 0.04J 12J 31 12J 11B MW-7 16-Apr-14 50J 0.21 1.1 10J 46 19 3J 0.04J 17J 31 0.091 23J 40B MW-7 11-Nov-14 0.5J 70J 0.41 0.7J 23 26 45 7J 0.28 13J 21 0.2J 5J 22 MW-7 30-Apr-15 60J 0.11 0.91 51 48 11 2J 0.04J 17J 0.081 33 MW-7 14-Oct-15 40J 0.1J 0.41 71 30 10 2J 0.02J 10J 11 0.05J 31 MW-7 20-Apr-16 40J 0.061 1.0 21 52 71 2J 0.03J 17J 21 11 MW-7 13-Sep-16 0.24J 44J 1.6 1.41 41 5.5JB 1.1J 12J 4.0J 13 MW-7 18-Apr-17 34J 0.131 0.831 6.1J 31 30 16 0.037J 9.2J 8.1J 7.41 MW-7 18-Sep-17 0.52J 27J 23 1.11 6.8J MW-7 11-Apr-18 411 1.5 3.71 32 7.61 1.11 111 5.7J 29 MW-7 (dissolved) 11-Apr-18 NA NA NA NA NA NA 31 NA NA NA NA NA NA NA NA MW-7 25-Oct-18 52J 1.3 3.31 34 22 8.6J 10J 8.6J 30 MW-7 (dissolved) 25-Oct-18 NA NA NA NA NA NA 37 NA NA NA NA NA NA NA NA MW-7 24-Apr-19 35J 17 6.4J 12 MW-7 4-Nov-19 46 0.381 0.84 13 27 38 10 0.17131 8.9 0.261 0.18J 26 24B MW-7 8-Apr-20 48 0.451 3.81 41 9.8 2.8 11 5.7 41 MW-7 (dissolved) 8-Apr-20 NA NA NA NA NA NA 44 NA NA NA NA NA NA NA NA MW-7 14-Oct-20 40 0.301 35 1.4J 9.1 9.11 MW-7 31-Mar-21 46 0.371 3.2J 47 10 2.5 13 8.1 17 MW-7 (dissolved) 31-Mar-21 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-7 9-Nov-21 28 0.201 20 0.29J 7.0 MW-7 30-Mar-22 1 1 32 1 1 1 1 34 1 3.2J 10 5.4J Smith Page 3 of 30 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-8 24-Apr-12 0.937J 41.3.1 1.21.1 3.19J 1.83J 515 MW-8 22-Oct-12 41.8.1 0.146.1 0.404J 1.20J 2.76J 1.97J MW-8 17-Apr-13 0.8J 50J 0.08J 2.1 1.1 0.03J 4J 9.113 MW-8 16-Oct-13 50J 0.1J 0.2.1 2.1 2.1 4J MW-8 16-Apr-14 50J 0.07J 1.1 1.1 5J 5J 107 MW-8 12-Nov-14 50J 0.6J 0.4.1 5J 5J13 MW-8 30-Apr-15 80J 0.1J 0.1J 4.1 2.1 2.1 0.2J 7J 14 MW-8 15-Oct-15 80J 0.08J 0.1J 2.1 2.1 0.3.1 0.04J 6J 6.1 MW-8 21-Apr-16 70J 0.8J 2.1 0.02J 6J 0.05J13 6.1 MW-8 14-Sep-16 65J 0.13.1 1.9J 0.27JB 6.6J 2.9J 8.5JB MW-8 20-Apr-17 61.1 4.9J 1.81 4.7.1 MW-8 18-Sep-17 73J 0.14.1 0.85.1 4.6J 3.0J 5.7.1 M W-8 12-Apr-18 65J 4.2.1 5.2J 4.5.1 MW-8 24-Oct-18 71.1 2.7.1 5.0J 7.0.1 MW-8 22-Apr-19 110 1.3.1 9.4J 0.11J 8.2J 2.6J 120 MW-8 (dup) 22-Apr-19 110 9.51 8.11 2.5J 5.6.1 MW-8 7-Nov-19 48 6.4 1.6.1 2.5.1 0.3213 5.4 6.0 12 MW-8 (dissolved) 7-Nov-19 NA NA NA NA NA NA 1.5.1 NA NA NA NA NA NA NA 2.6J NA MW-8 9-Apr-20 43 2.5.1 4.8J 8.4.1 M W-8 15-Oct-20 81 6.6 8.1 5.8.1 MW-8 31-Mar-21 63 0.63 13 2.3.1 3.3.1 0.51J 6.4 8.9 11 M W-8 10-Nov-21 95 4.7.1 8.4 5.1J MW-8 29-Mar-22 1 86 1 1 8.8 1 1 1 11 1.4J 5.6.1 MW-8d 26-Apr-12 1.63J 34.5.1 11B 2.82J 4.15J 7.52J MW-8d 24-Oct-12 1.591 30.6J 0.483J 5.46J 3.21J 4.79J 9.99J MW-8d 18-Apr-13 0.6J 20J 4.1 0.3.1 1.1 0.2J 1J 0.06J 2J6 MW-8d 17-Oct-13 40J 0.2J 0.3J 6J 1J 6J 11 0.03J 21 7J MW-8d 17-Apr-14 0.9J 20J 0.1J 4.1 0.4.1 2.1 0.3J 0.8J 7J 5J13 MW-8d 12-Nov-14 1.0J 20J 4.1 0.3.1 2.1 0.3J 0.91 2.113 MW-8d 30-Apr-15 2.5J 0.6J 20J 0.1J 3.1 0.4.1 1.1 0.4J 1J 2J 4.1 MW-8d 15-Oct-15 0.2J 20J 3.1 0.06J 0.05J 0.5J 1J13 MW-8d 21-Apr-16 20J 3.1 0.5J MW-8d 14-Sep-16 16J 1.7.1 0.60JB 0.047J13 0.72J 4.8J 2.0.113 MW-8d 20-Apr-17 19.1 2.6.1 4.3.1 4.0J 3.1J MW-8d 18-Sep-17 16J 2.9.1 3.1 MW-8d (dup) 18-Sep-17 17J 3.2.1 2.8J MW-8d 12-Apr-18 17J 3.5.1 MW-8d 23-Oct-18 18J 6.5.1 2.2J 4.4J MW-8d (dup) 23-Oct-18 17J 6.3.1 2.0J 4.5J MW-8d 23-Apr-19 17J 4.0.1 3.9J MW-8d 6-Nov-19 21 0.22J 3.9.1 3.2.1 1.4J 3.9J 14 MW-8d 8-Apr-20 0.50J 28 0.25J 4.5.1 0.45J 5.8J MW-8d 13-Oct-20 1.3J 25 0.55 3.7.1 1.7J 0.25J 3.9J 15 MW-8d 31-Mar-21 1.5.1 35 0.21J 4.8.1 3.2.1 1.5 1.3J 6.1 8.4.1 MW-8d (dup) 31-Mar-21 2.6 35 0.23J 6.9 4.7J 1.8 2.5J 8.4 12 MW-8d 10-Nov-21 16 3.1J 4.2J MW-8d 29-Mar-22 17 3.6J 4.1 Smith Page 4 of 30 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 25-Apr-12 176 0.220J 5.68.1 4.81.1 2.72.1 13.5 MW-9 MW-9 23-Oct-12 5.17.1 210 0.711J 4.13 19.7 6.96J 17.1 27.2 3.41J 7.49J 0.521J 30.2 141 MW-9 17-Apr-13 160 0.3J13 2 3.1 4.1 4.1 4J 4J 0.1 81 27B MW-9 16-Oct-13 120 0.2J 1.1 2.1 0.4.1 2.1 11 2J 0.2J 6J 16B MW-9 16-Apr-14 130 0.4J 1.3 4.1 0.8J 5.1 4J 3J 0.1 16J 36B MW-9 12-Nov-14 120 0.3J 0.4.1 4.1 0.6J 4.1 3J 2J 0.2J 17 MW-9 (dup) 12-Nov-14 140 0.5J 0.4J 6.1 1.1 6.1 6J 2J 0.3J 4J 28 MW-9 29-Apr-15 0.7J 90J 0.1J 0.3.1 2.1 0.1J 1.1 0.81 0.81 0.2J 1 8.1 MW-9 15-Oct-15 160 0.7J 0.2J 9.1 1.1 6.1 7J 0.07J 1J 0.3J 11JB 31 MW-9 20-Apr-16 150 0.2J 2.1 0.2.1 1.1 0.7J 0.91 0.11 3.1 MW-9 13-Sep-16 100 0.15J 0.12.1 1.7.1 1.3JB 1.OJ 1.2J 0.16J 11JB 9.4.1 MW-9 19-Apr-17 130 2.1J 1.0.1 0.52J 7.4J 4.6J MW-9 21-Sep-17 160 1.4 0.37J 13 1.9.1 11 15 2.1J 0.40J 34 49 MW-9 (dissolved) 21-Sep-17 NA NA NA NA NA NA NA NA NA NA NA 11J NA MW-9 11-Apr-18 130 0.16J 3.2.1 0.61J 3.OJ 0.20J 5.5J 4.5J MW-9 (dissolved) 11-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA NA 5.6J NA MW-9 25-Oct-18 89J 2.1J 0.15J 11J MW-9 25-Apr-19 150 1.1 2.3.1 0.39J 2.4J 7.1J 6.9.1 MW-9 7-Nov-19 230 0.17J 1.5 3.8.1 11 2.1 0.22 4.7J 1.7J 0.22J 10 57 MW-9 (dissolved) 7-Nov-19 NA NA NA NA NA NA NA NA NA NA NA NA NA 0.21J 6.7 NA MW-9 9-Apr-20 270 2.2 11 2.8.1 0.44J 6.4 0.21J 3.9J 30 MW-9 15-Oct-20 0.96J 320 1.3 2.3.1 0.58J 5.5 0.21J 9.9 14 MW-9 31-Mar-21 390 0.15J 2.7 2.4.1 1.4.1 11 1.4 8.9 0.16J 9.3 25 MW-9 9-Nov-21 360 2.8 4.4.1 8.5 0.25J 9.2 0.25J 31 MW-9 30-Mar-22 370 0.33J 7.8 3.9.1 4.4.1 65 3.4 10 0.60J 0.36J 6.7 47 MW-9 (dissolved) 30-Mar-22 NA NA NA NA 6.4 NA NA NA NA NA NA NA NA NA NA NA MW-10 25-Apr-12 34.7.1 0.320J 0.438.1 1.79.1 2.04J 4.81.1 2.64J 0.538 2.25J 21.7 MW-10 23-Oct-12 31.1.1 0.302J 0.965.1 2.07J 2.51J 2.57J 0.910 2.07J 16.5 MW-10 17-Apr-13 30J 0.3J13 0.4J 0.4.1 2.1 2JB 11 0.43 3J 0.06J 14B MW-10 16-Oct-13 30J 0.3.1 0.2J 0.4.1 2.1 2.1 11 0.29 3J 0.05J 4J 9.113 MW-10 16-Apr-14 30J 0.3.1 0.2J 2.1 1.1 0.5J 0.05J 3J 4J 38B MW-10 12-Nov-14 30J 0.3.1 2.1 0.03J 3J 9.113 MW-10 29-Apr-15 0.2J 40J 0.3.1 0.1J 3.1 2.1 11 0.101 5J 0.05J 10 MW-10 14-Oct-15 30J 0.3.1 0.2J 2.1 0.8J 0.4J 0.08J 3J 27 MW-10 20-Apr-16 30J 0.3.1 0.1J 4.1 0.6J 0.3J 0.03J 5J 1.1 0.05J 41 MW-10 13-Sep-16 0.47J 31.1 0.36.1 0.19.1 3.8.1 2.OJB 1.2J 0.14J 4.8J 3.6J 280 MW-10 19-Apr-17 27J 0.32.1 2.9.1 0.93.1 0.38J 0.064J 3.4J 17 MW-10 22-Sep-17 17J 0.18.1 1.3.1 2.2.1 0.30J 2.3J 2.1J 8.9.1 MW-10 11-Apr-18 20J 0.32.1 0.87.1 1.9.1 2.4.1 1.3.1 0.55J 0.27 2.5J 51 MW-10 25-Oct-18 24J 0.16.1 0.72.1 2.3.1 0.57J 0.39 2.7J 7.4J 77 MW-10 (dissolved) 25-Oct-18 NA NA NA NA NA NA 2.6.1 NA NA NA NA NA NA NA NA MW-10 25-Apr-19 25J 1.7.1 2.7.1 0.45J 5.1J 2.5.1 MW-10 7-Nov-19 20 0.24J 2.6.1 2.6.1 0.50J 0.12J 4.3J 2.5J 66 MW-10 (dissolved) 7-Nov-19 NA NA NA NA NA NA 2.2.1 NA NA NA NA NA NA NA NA NA MW-10 7-Apr-20 23 0.17J 1.3J 2.7J 0.61J 0.14J 4.OJ 15 MW-10 15-Oct-20 4.8 12 0.49J 1.4J 1.5.1 0.32J 2.4J 33 MW-10 31-Mar-21 16 0.16J 1.1 56 5.8 0.47J 0.097J 4.OJ 4.5J 31 MW-10 10-Nov-21 17 0.20J 0.65 2.3J 17 MW-10 30-Mar-22 17 1 0.16J 0.77 2.8J 1.4J 1 6.7 0.27J 3.7J 19 Smith Page 5 of 30 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-10d 26-Apr-12 0.232J 4.36.1 3.50J 3.47JB 4.57J MW-10d 24-Oct-12 3.11.1 MW-10d 18-Apr-13 4J13 1J13 0.07J 0.7J 1J MW-10d 16-Oct-13 0.3J 3J13 0.2.1 1.1 0.05J 0.7J 0.6J MW-10d 17-Apr-14 2.1 0.4.1 0.6J 4J 3.113 MW-10d 12-Nov-14 3.1 0.5.1 0.04J 0.4.1 MW-10d 30-Apr-15 0.8J 0.5.1 3.1 0.3.1 0.3.1 0.05J 0.6J 4.1 MW-10d 15-Oct-15 0.5J 5.1 0.07J 0.8.1 0.08J 1.1 0.2J 0.07J 0.6J 5.1 MW-10d 21-Apr-16 0.3J 5.1 0.2J 2.1 1.1 2J 6.1 MW-10d 14-Sep-16 2.5.1 0.67JB 0.15J 3.3J 5.5JB MW-10d 19-Apr-17 2.5.1 0.14.1 0.70J MW-10d 18-Sep-17 4.1J 0.35.1 1.4.1 3.1J 0.32J 6.9.1 MW-10d 11-Apr-18 0.60J 3.7.1 0.60J 1.8.1 2.1J 0.34J 14 MW-10d 25-Oct-18 2.5.1 MW-10d 25-Apr-19 2.8.1 3.0.1 MW-10d 5-Nov-19 3.7.1 0.14.1 1.3.1 0.34J 0.09813J 6.213.1 MW-10d 9-Apr-20 2.8.1 2.7.1 MW-10d 14-Oct-20 2.3.1 3.4.1 MW-10d 31-Mar-21 1.4J 4.5.1 0.27.1 3.6.1 2.0.1 0.29J 3.4J 10 MW-10d 9-Nov-21 0.72J 4.3.1 0.53 2.3.1 4.4.1 0.45J 2.0J 8.6.1 MW-10d 29-Mar-22 0.59J 5.5 0.70 3.0.1 12 0.81J 1.5J 10 MW-22 25-Apr-12 61.5.1 0.224.1 4.78 4.77.1 63.8 14J 2.56.1 0.162J 33.1 18.4 MW-22 23-Oct-12 34.7.1 8.27 2.28.1 44.7 16.8J 4.02J 19.2 MW-22 17-Apr-13 70J 0.1J 4 0.9J 76 1JB 0.7J 15J 0.06J 12B MW-22 16-Oct-13 50J 0.1J 3.5 1.1 25 1.1 11 101 1 8.113 MW-22 16-Apr-14 50J 0.1J 2.5 0.9J 43 1.1 11 14J 4J 14B MW-22 12-Nov-14 40J 0.1J 2.5 3.1 17 2.1 2J 101 9.1 MW-22 30-Apr-15 50J 1.5 0.6J 31 0.7J 0.6J 101 91 MW-22 15-Oct-15 80J 0.7J 3.4 9.1 29 5.1 91 0.05J 13J 4.1 0.2J 14JB 56 MW-22 20-Apr-16 40J 0.07J 1.3 18 0.5J 0.3J 7J 6.1 MW-22 13-Sep-16 82J 0.82.1 3.1 12 38 6.9JB 11 14J 3.1J 0.20J 18J 47 MW-22 19-Apr-17 45J 0.26.1 2.8 1.9.1 18 2.6.1 1.6J 6.5J 0.93.1 6.4J 13 MW-22 18-Sep-17 M W-22 13-Apr-18 MW-22 23-Oct-18 Not Sampled(') MW-22 23-Apr-19 MW-22 4-Nov-19 MW-22 8-Apr-20 MW-22 14-Oct-20 48 0.16J 1.5 2.3.1 40 1.7.1 3.2 11 3.6J 14 MW-22 31-Mar-21 27 0.91 18 0.27J 4.8J 7.6.1 MW-22 10-Nov-21 31 1.9 1.7.1 34 2.5.1 0.35J 12 15 MW-22 30-Mar-22 30 0.37J 40 11 8.8.1 Smith Page 6 of 30 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 10.4E 7.07J 4.20J 12.5J 17.5 MW-23 26-Apr-12 42.7.1 6.68.1 1.63.1 MW-23 24-Oct-12 38.9.1 5.76.1 1.83.1 8.02J 4.12J 3.92J 13.1 18.5 MW-23 18-Apr-13 0.2J 240 1.8 0.1J 30 15 56 30 0.06J 28J 11 106 147 MW-23 16-Oct-13 30J 0.2.1 0.1J 3.1 0.7J 4.1 2J 0.02J 2J 5J 6.113 MW-23 16-Apr-14 50J 0.3.1 0.2.1 7.1 2.1 10 5J 4J 0.11 16J 25B MW-23 12-Nov-14 50J 0.4.1 7.1 2.1 12 6J 0.02J 5J 0.11 12J 19 MW-23 30-Apr-15 0.4J 50J 0.3.1 7.1 2.1 13 6J 0.03J 6J 0.11 15J 26 MW-23 15-Oct-15 110 1.1 20 7J 34 18 0.06J 16J 0.5J 39 69 MW-23 (dup) 15-Oct-15 170 1.6 32 11 51 30 0.12J 25J 0.8J 60 112 MW-23 20-Apr-16 40J 0.3.1 5.1 1.1 9.1 5J 4J 0.11 91 21 MW-23 13-Sep-16 54J 0.59.1 0.083J 8.9.1 3.3.1 15B 7.7J 6.9J 0.22J 23J 39 MW-23 19-Apr-17 26J 0.19.1 3.3.1 4.5.1 2.1J 2.4J 6.5J 7.2.1 MW-23 20-Sep-17 110 1.5 0.14J 19 6.6J 33 17 16J 0.48J 59 67 MW-23 (dissolved) 20-Sep-17 NA NA NA NA NA NA NA NA NA NA 3.1 NA MW-23 11-Apr-18 85J 0.86.1 0.22.1 12 4.4.1 21 11 14J 0.28J 30 44 MW-23 (dissolved) 11-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA MW-23 25-Oct-18 51J 0.26.1 0.62.1 9.2.1 3.1J 12 5.6J 8.3J 0.191 21J 45 MW-23 (dissolved) 25-Oct-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-23 25-Apr-19 42J 0.19.1 5.6.1 1.8.1 8.0.1 4.6J 4.2J 13J 30 MW-23 (dissolved) 25-Apr-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-23 5-Nov-19 39 0.35J 6.0 1.7.1 10 5.3 4.3J 0.23J 13 24B MW-23 (dissolved) 5-Nov-19 NA NA NA NA NA NA NA NA NA NA NA NA 0.20J NA MW-23 8-Apr-20 110 0.44 12 4.6.1 26 18 9.2 0.23J 28 39 MW-23 (dissolved) 8-Apr-20 NA NA NA NA NA 1.7.1 NA NA NA NA NA NA MW-23 14-Oct-20 19 1.9.1 1.8.1 1.0 3.8J 2.8.1 MW-23 31-Mar-21 25 4.2.1 6.2 3.0 2.7J 9.1 12 MW-23 10-Nov-21 11 1.4.1 0.39J 3.OJ MW-23 30-Mar-22 26 2.5J 14J MW-23d 25-Apr-12 0.754J 35J 0.746.1 4.03J 16.8E 3.32J 4.05J 6.65.1 MW-23d 23-Oct-12 0.552J 33.2.1 0.644.1 4.73.1 4.38.1 4.48J 8.66.1 MW-23d 18-Apr-13 2.6J 40J 1.5 3J13 0.3.1 4.1 0.4J 1J 12B MW-23d 17-Oct-13 1.7J 40J 0.05J 0.7.1 2.1 0.3.1 3.1 0.3J 0.02J 1J 1 3.113 MW-23d 17-Apr-14 1.3J 30J 0.3.1 2.1 0.3.1 2.1 0.3J 1J 6J 8.113 MW-23d 13-Nov-14 1.1J 40J 0.2J 2.1 0.3.1 2.1 0.3J 0.8J 2J 6.1 MW-23d 29-Apr-15 1.6J 40J 0.2J 2.1 0.3.1 2.1 0.3J 0.91 2J 6.1 MW-23d 15-Oct-15 3.6J 40J 0.04J 0.5.1 3.1 0.4.1 4.1 0.6J 0.05J 11 2J13 13 MW-23d 20-Apr-16 1.1J 40J 0.2J 3.1 0.3.1 2.1 0.2J 4J 7.1 MW-23d 13-Sep-16 1.2J 37J 0.23.1 2.3.1 0.26.1 2.5JB 0.48J 2.5J 6.1J 13 MW-23d (dup) 13-Sep-16 0.97J 36J 0.22.1 1.9.1 2.2JB 0.36J 2.2J 5.7J 10 MW-23d 19-Apr-17 0.53J 34J 0.24.1 2.0.1 4.9.1 1.4J 3.7J 6.9.1 MW-23d 21-Sep-17 34J 2.7.1 3.8.1 3.5J 5.8.1 MW-23d 10-Apr-18 38J 5.2.1 2.4.1 0.32J 1.8J 2.6J 3.4.1 MW-23d (dup) 10-Apr-18 36J 4.8.1 2.3.1 1.7J 3.1J MW-23d 23-Oct-18 36J 14 7.OJ 4.OJ MW-23d 23-Apr-19 41J 2.2J 3.9J MW-23d 4-Nov-19 1.7J 34 0.91 2.2J 4.1J 0.35J 0.09613J 1.3J 3.8J 21B MW-23d 8-Apr-20 1.11 33 0.80 3.5J 3.5J 0.47J 1.5J 29 MW-23d 13-Oct-20 7.3 34 0.93 2.1J 3.2J 0.51J 1.5J 3.7J 29 MW-23d (dup) 13-Oct-20 7.6 35 0.92 2.4J 3.4J 0.64J 1.6J 3.6J 25 MW-23d 31-Mar-21 0.61J 37 0.21J 9.8 2.9J 0.26J 1.3J 3.7J 14 MW-23d 9-Nov-21 35 2.OJ 3.9J MW-23d (dup) 9-Nov-21 35 1.91 3.8J MW-23d 29-Mar-22 35 2.OJ 1.6J 1.1 3.8J MW-23d (dup) 29-Mar-22 36 2.2J 4.1J Smith Page 7 of 30 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-24 26-Apr-12 57.6.1 0.281.1 7.54.1 7.09JB 9.80J 3.35J 1.82J 0.190J 8.38J 58.7 MW-24 23-Oct-12 35.9.1 2.10J 2.50J 4.01J 0.120J 5.34J 28.3 MW-24 17-Apr-13 120 1.4.1 0.1J 9.1 2.1 11 17 0.24 5J 0.5J 17J 128 MW-24 16-Oct-13 60J 0.6J 0.1J 4.1 0.9J 5.1 7J 0.091 2J 0.2J 81 46 MW-24 16-Apr-14 120 1.1 6.1 2.1 9.1 14 0.17J 4J 0.4J 22J 120 MW-24 12-Nov-14 130 1.5 8.1 2.1 11 17 0.21 5J 0.6J 14J 117 MW-24 29-Apr-15 80J 0.8J 4.1 1.1 7.1 91 0.12J 3J 0.3J 101 69 MW-24 14-Oct-15 240 2.5 0.2J 12 4.1 18 29 0.43 7J 0.91 34 182 MW-24 20-Apr-16 170 1.8 101 3.1 13 22 0.21 6J 0.7J 23J 140 MW-24 13-Sep-16 34J 0.37.1 0.086J 1.4.1 0.55.1 2.3JB 3.6J 1.5J 0.12J 7.5J 31 MW-24 19-Apr-17 66J 0.77.1 3.8.1 0.98.1 5.0.1 7.9J 0.086J 2.5J 0.24J 9.11 56 MW-24 20-Sep-17 51.1 0.76.1 3.9.1 0.71.1 4.6.1 5.8J 2.4J 0.191 7.5J 47 MW-24 (dissolved) 20-Sep-17 NA NA NA NA NA NA NA NA NA NA NA NA NA 3.6J NA MW-24 11-Apr-18 62J 0.75.1 4.8.1 5.0.1 7.1J 2.6J 0.22J 6.9J 49 MW-24 (dissolved) 11-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-24 23-Oct-18 MW-24 24-Apr-19 (') Not Sampled MW-24 4-Nov-19 MW-24 8-Apr-20 0 2.5J I I I MW-24 31 -Mar 21 15 0.20J 1.71 0.80J 3.2J 7.61 MW-24 9-Nov-21 Not Sampled(') MW-24 30-Mar-22 19 2.91 0.61J 1.8J 2.6J 5.61 MW-28 26-Apr-12 67.71 14.2 3.901 2.81JB 5.18J 5.84J 0.229J 20.7J 69.8 MW-28 18-Apr-13 60J 0.31 30 31 11 11 4J 0.2J 10J 34B MW-28 17-Apr-14 170 1.5 41 14 51 7J 0.02J 20J 1.01 53 159 MW-28 30-Apr-15 80J 0.51 16 5J 21 2J 0.02J 7J 0.4J 22J 62 MW-28 21-Apr-16 20J 41 0.061 91 MW-28 20-Apr-17 29J 0.181 3.91 0.30J 1.1 6.1J 11 MW-28 13-Apr-18 55J 0.411 11 2.71 1.1 5.11 0.16J 151 22 MW-28 (dissolved) 13-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA 2.6J NA MW-28 25-Apr-19 56J 0.171 8.91 2.61 1.2J 4.4J 0.151 151 37 MW-28 (dissolved) 25-Apr-19 NA NA NA NA NA NA NA NA NA NA NA NA NA 2.8J NA MW-28 8-Apr-20 76 0.311 14 4.71 2.5 7.1 0.38J 24 54 MW-28 (dissolved) 8-Apr-20 NA NA NA NA NA 3.21 NA NA NA NA NA NA NA MW-28 31-Mar-21 32 0.161 5.7 2.61 1.1 1.91 8.4 29 MW-28 29-Mar-22 33 0.20.11 6.3 1.31 1.61 0.90J 2.2J 1.1 1 9.5 22 MW-28d 26-Apr-12 1.46J 28.71 10.1 1.341 13.3E 4.99J 9.42J 4.71 106 MW-28d 18-Apr-13 0.31 9113 2J13 0.11 0.91 0.91 416 MW-28d 17-Apr-14 0.41 1.1 61 41 0.41 31 1.01 51 6J 10B MW-28d 30-Apr-15 0.21 101 21 0.091 0.61 0.91 71 MW-28d 21-Apr-16 91 21 0.81 91 91 MW-28d 20-Apr-17 8.11 1.31 0.681 3.1 5.91 MW-28d 13-Apr-18 5.81 1.91 6.91 MW-28d 25-Apr-19 7.11 2.01 1.51 1.5J 3.1 9.91 MW-28d (dissolved) 25-Apr-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA 2.5J NA MW-28d 8-Apr-20 7.3 2.61 1.1 9.11 MW-28d 31-Mar-21 15 2.91 3.81 1.2 6.3 6.7 15 MW-28d 29-Mar-22 0.551 13 2.61 7.0 1.4 2.4J 1.1 5.2 31 Smith Page 8 of 30 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-29d 26-Apr-12 0.317J 41.5.1 6.48.1 8.73JB 3.94J 1.97J 3.72J 23.2 MW-29d 24-Oct-12 38.0.1 4.87.1 6.36J 2.48J 4.36J 7.64.1 MW-29d 18-Apr-13 40J 0.08J 4.1 0.4.1 5.1 0.3J 1J 0.05J 3.113 MW-29d 17-Oct-13 40J 0.1J 4.1 0.2.1 3.1 11 MW-29d 17-Apr-14 40J 0.08J 3.1 0.2.1 3.1 0.81 5J 25B MW-29d 13-Nov-14 40J 0.07J 3.1 0.5.1 4.1 0.3J 2J 2.1 MW-29d 29-Apr-15 0.2J 0.51 40J 0.1J 4.1 0.3.1 4.1 0.3J 11 13 MW-29d 15-Oct-15 0.2J 40J 0.1J 4.1 0.3.1 4.1 0.6J 0.04J 11 8.1 MW-29d 21-Apr-16 0.61 40J 4.1 0.3.1 5.1 0.2J 11 6.1 MW-29d 12-Sep-16 0.38J 39J 2.7.1 3.1JB 0.25J 0.901 4.8J 22 MW-29d 19-Apr-17 36J 2.7.1 1.9.1 2.3J 13 MW-29d 22-Sep-17 35J 3.9.1 2.8.1 5.9J MW-29d 12-Apr-18 34J 3.7.1 1.3.1 5.4J MW-29d 24-Oct-18 34J 3.2.1 3.3J 2.7.1 MW-29d 25-Apr-19 38J 3.3.1 MW-29d 5-Nov-19 33 3.4.1 3.9.1 0.36J 0.09213J 2.0J 39B MW-29d 6-Apr-20 1.4J 43 0.24J 11 19 2.5 4.1J 3.8J 30 MW-29d 14-Oct-20 1.3J 37 0.13J 3.6.1 2.5.1 0.38J 45 MW-29d 31-Mar-21 0.64J 45 5.6 6.9 0.73J 2.0 3.3J 88 MW-29d 9-Nov-21 35 2.3.1 MW-29d 29-Mar-22 0.67J 25 4.9.1 8.9 1.4 3.1J 0.29.1 140 MW-30 25-Apr-12 169 0.773J 58 9.94J 73.9 9.17J 22.7J 2.15.1 0.360J 51.7 54.7 MW-30 23-Oct-12 197 57.5 11.3 80.2 9.44J 26.3 0.359J 54.4 62.6 MW-30 17-Apr-13 450 2.8 0.1J 124 24 155 17 0.04J 56 11 146 141 MW-30 16-Oct-13 220 1.4 49 91 63 6J 0.03J 21J 0.3J 50 40 MW-30 16-Apr-14 220 1.4 66 11 78 7J 0.02J 26J 0.5J 73 71 MW-30 12-Nov-14 500 3.0 0.2J 148 24 169 19 0.07J 59 2.1 1.11 154 148 MW-30 29-Apr-15 180 1.2 59 91 67 6J 23J 0.4J 48 53 MW-30 15-Oct-15 0.4J 60J 1.2 0.7J 48 11 12 2J 0.05J 10J 0.06J 63 44 MW-30 21-Apr-16 150 0.8J 46 7J 54 5J 0.02J 18J 0.3J13 29 38 MW-30 14-Sep-16 0.17J6 50J 0.36.1 0.053J 8.8.1 1.6.1 11B 0.95J 4.5J 11J 18B MW-30 20-Apr-17 79J 0.56.1 25 3.1J 28 2.2J 8.7J 0.14J 191 22 MW-30 22-Sep-17 M W-30 12-Apr-18 MW-30 24-Oct-18 Not Sampled(') MW-30 25-Apr-19 MW-30 5-Nov-19 MW-30 8-Apr-20 MW-30 15-Oct-20 1.4J 67 0.32J 0.46J 7.1 1.3J 11 2.4 4.2J 8.4 29 MW-30 (dissolved) 15-Oct-20 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-30 31-Mar-21 78 0.261 0.161 13 2.51 9.4 2.5 4.2J 11 24 MW-30 (dissolved) 31-Mar-21 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-30 9-Nov-21 3 Not Sampled MW-30 28-Mar-22 Smith Page 9 of 30 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-31 25-Apr-12 33.41 0.1221 13.1 6.711 3.56J 5.40J 0.904J 9.25J 33.1 MW-31 23-Oct-12 35.71 14 6.521 3.76J 5.09J 9.26J 53.6 MW-31 17-Apr-13 70J 0.41 24 11 14 7J 0.03J 81 0.05J 18J 29B MW-31 16-Oct-13 30J 0.11 11 0.41 51 2J 5J 5J 13B MW-31 16-Apr-14 901 0.51 0.2J 32 21 18 10 0.07J 81 0.07J 35 70 MW-31 12-Nov-14 0.5J 110 0.71 41 21 26 14 0.08J 11J 0.1J M 29 MW-31 29-Apr-15 50J 0.21 14 0.61 71 4J 0.03J 3J 13J 14 MW-31 14-Oct-15 0.5J 120 0.61 38 21 24 13 0.111 91 0.081 37 37 MW-31 21-Apr-16 0.61 70J 0.5J 30 2J 17 12 0.14J 51 0.07J6 17 MW-31 13-Sep-16 29J 0.23.1 13 0.64J 5.613 3.4J 2.0J 12J 12 MW-31 19-Apr-17 28J 8.3J 3.9J 1.8J 2.6J 0.22J 5.2J 12 M W-31 21-Sep-17 M W-31 12-Apr-18 M W-31 24-Oct-18 Not Sampled(') MW-31 24-Apr-19 M W-31 5-Nov-19 M W-31 8-Apr-20 MW-31 15-Oct-20 41 0.221 16 7.8 3.9 7.4 14 14 MW-31 (dissolved) 15-Oct-20 NA NA NA NA NA 3.0 NA NA NA NA NA NA NA NA NA NA MW-31 31-Mar-21 25 11S 5.3 2.1 1.6J 12 6.3.1 MW-31 10-Nov-21 17 3.0.1 1.5J 4.1J 9.2.1 MW-31 29-Mar-22 17 3.7.1 1.3J 0.31 1.91 3.1 5.6.1 MW-31d 24-Apr-12 1.68J 17.1J 6.791 26.5 0.944J 7.62J 12.6 MW-31d 22-Oct-12 7.20J 19.31 8.241 1.821 7.99J 43.5 MW-31d 16-Apr-13 0.5J 20J 61 0.081 0.8JB 1J 6J 21B MW-31d 15-Oct-13 0.8J 20J 61 0.061 11 0.8J 5J 16B MW-31d 15-Apr-14 0.7J 20J 51 0.091 0.81 0.91 91 24B MW-31d 11-Nov-14 0.5J 20J 61 0.081 0.81 0.7J 2J 71 MW-31d 28-Apr-15 1.1J 20J 61 0.071 0.91 0.8J 5J 24 MW-31d 13-Oct-15 1.2J 20J 0.3J 61 0.051 31 0.2J 0.04J 1J 4J 30 MW-31d 21-Apr-16 20J 41 0.71 0.91 2J 51 MW-31d 13-Sep-16 0.59J 18J 0.14J 5.31 1.5JB 1.2J 7.2J 56 MW-31d 19-Apr-17 18J 5.41 2.61 6.6J 53 MW-31d 18-Sep-17 191 4.41 1.01 7.8J 2.61 MW-31d 13-Apr-18 0.51J 18J 5.31 4.6J 25 MW-31d (dissolved) 13-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA 4.1 NA MW-31d 24-Oct-18 21J 6.6.1 0.28J 1.81 9.91 4.01 MW-31d 24-Apr-19 21J 4.2.1 7.8J MW-31d 5-Nov-19 0.63J 17 0.211 4.1J 1.61 0.092J 6.3 84B MW-31d 8-Apr-20 18 4.4.1 0.41 7.6 20 MW-31d (dissolved) 8-Apr-20 NA NA NA NA NA NA NA NA NA NA NA NA NA NA 7.3 NA MW-31d 15-Oct-20 0.80J 19 4.4.1 6.6 26 MW-31d 31-Mar-21 0.99J 20 0.201 4.9.1 1.91 6.6 87 MW-31d 9-Nov-21 21 3.81 0.28J 8.7 4.01 MW-31d 29-Mar-22 0.95J 23 0.271 5.8 6.5 0.55J 2.6J 1.4J 6.5 100 Smith Page 10 of 30 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-32 25-Apr-12 0.393J 3.37J 15.4.1 0.261.1 1.92.1 2.34.1 8.49.1 1.96J 5.71J 6.22.1 MW-32 23-Oct-12 30J 6.71.1 3.30J 27.2 5.04J 11.81 13.1 MW-32 17-Apr-13 30J 0.3.1 5.1 3.1 22 0.5J 5J 91 8.113 MW-32 16-Oct-13 70J 0.6J 0.3.1 11 6J 50 0.91 101 0.11 32 25 MW-32 16-Apr-14 20J 0.3.1 2.1 2.1 8.1 0.2J 2J 7J 10B MW-32 12-Nov-14 50J 0.5.1 11 5.1 37 0.91 91 0.11 15J 18 MW-32 29-Apr-15 0.61 140 1.6 0.1J 27 18 131 3J 24J 0.3J 77 58 MW-32 14-Oct-15 170 1.4 0.1J 29 18 135 2J 0.04J 25J 0.3J 91 53 MW-32 21-Apr-16 40J 0.5.1 6.1 5.1 28 0.5J 6J 0.08J13 17J 18 MW-32 13-Sep-16 40J 0.63.1 0.20J 8.5.1 5.6.1 27B 0.75J 7.2J 0.086J 18J 19 MW-32 20-Apr-17 11.1 0.30J 1.6.1 0.90J 5.1J 1.4J 2.7J 3.5.1 MW-32 22-Sep-17 0.66J 14J 0.17.1 1.6.1 1.3.1 1.3J 4.0.1 MW-32 13-Apr-18 8.5.1 0.30J 1.5.1 2.7.1 MW-32 25-Oct-18 13J 0.26.1 3.1J 1.8.1 1.6J 2.5.1 MW-32 (dissolved) 25-Oct-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-32 25-Apr-19 26J 0.33.1 0.30J 2.6.1 11 9.5.1 5.0J 4.7J 27 MW-32 (dissolved) 25-Apr-19 NA NA NA NA NA NA 6.2 NA NA NA NA NA NA NA MW-32 7-Nov-19 13 0.21J 2.4.1 3.6.1 0.28 2.2J 3.0.1 MW-32 (dissolved) 7-Nov-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-32 8-Apr-20 14 0.24J 3.5.1 2.4.1 13 0.42J 3.0J 2.5J 14 MW-32 (dissolved) 8-Apr-20 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-32 15-Oct-20 5.6 0.27J 5.9.1 MW-32 31-Mar-21 0.62J 11 0.27J 1.8.1 3.5.1 4.2.1 1.81 3.6J 11 MW-32 9-Nov-21 16 0.20J 2.4.1 7.7 2.1J 3.3J 5.2.1 MW-32 29-Mar-22 9.1 0.46 1.4.1 2.1J 3.2.1 1.4J 5.4 2.8.1 TB-1a 25-Apr-12 0.269J 190 1.5 29 22 158 7.33J 0.348 27.9J 0.186J 61.3 89.4 TB-1a 23-Oct-12 85.4.1 0.584J 11.3 14.8 59.6 2.35J 13.3J 25 48.2 TB-1a 17-Apr-13 40J 0.06J 0.3.1 5.1 91 24 0.91 0.11 6J 91 11B TB-1a 16-Oct-13 60J 0.08J 0.3.1 6.1 10 35 11 0.12J 91 14J 14B TB-1a 16-Apr-14 10J 1.2 0.7J 5.1 3.1 0.3J 0.13J 3J 5J 16B TB-1a 12-Nov-14 80J 0.2.1 2.7 101 91 54 2J 0.34 12J 0.081 191 41 TB-1a 29-Apr-15 0.6J 30J 0.06J 1.9 4.1 5.1 18 11 0.22 6J 6J 17 TB-1a 15-Oct-15 70J 0.1J 2.5 8.1 11 40 2J 0.22 13J 17JB 45 TB-1a 21-Apr-16 50J 0.7J 6.1 6J 33 11 0.22 7J 0.06J13 6J 18 TB-1a 14-Sep-16 0.17J6 99J 0.23.1 1.7 12 11 72B 3.5J 0.7213 15J 0.111 29 49B TB-1a 20-Apr-17 17J 0.37.1 1.0.1 3.6.1 0.050J 1.9J 5.1J 5.5J TB-1a 22-Sep-17 TB-1a 12-Apr-18 TB-1a 24-Oct-18 TB -la 24-Apr-19 Not Sampled(') TB-1a 5-Nov-19 TB -la 8-Apr-20 TB-1a 14-Oct-20 TB-1a 31-Mar-21 I I 19 I I 6.6 I 6.5 I 3.2.1 I 4.7.1 10.48J 10.10J I 4.7J I I I I 3.1J I 21 TB-1a 9-Nov-21 3 Not Sampled TB-1a 28-Mar-22 Smith Page 11 of 30 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 TB-1a deep 24-Apr-12 0.928J 15.5.1 15 11.5 3.87J 1.23J 6.58J 8.41J TB-1a deep 23-Oct-12 18.0.1 14.9 6.85.1 8.29J 6.51J 10.4 TB-1a deep 16-Apr-13 2.3J 20J 0.2.1 12 0.9J 8.1 0.5J 5J 2J 16B TB-1a deep 15-Oct-13 2.2J 20J 0.1J 6.1 1.1 6J 5J 4J 1 9.113 TB-1a deep 15-Apr-14 2.1J 20J 0.1J 7.1 0.8J 5.1 0.4J 3J 8J 17B TB-1a deep 11-Nov-14 2.9J 30J 0.1J 7.1 1.1 5.1 0.5J 4J 18 TB-1a deep 28-Apr-15 2.4J 30J 0.1J 7.1 0.8J 4.1 0.4J 5J 2J 12 TB-1a deep 14-Oct-15 10J 4.1 0.04J 11 TB-1a deep 20-Apr-16 0.4J 20J 4.1 0.7J 2.1 0.2J 3J 6.1 TB-1a deep 13-Sep-16 0.66J 22J 0.070J 3.1J 0.46.1 1.7JB 0.26J 3.2J 6.4J 12 TB-1a deep 19-Apr-17 0.74J 25J 3.2.1 3.0.1 3.3J 3.9J 13 TB-1a deep 22-Sep-17 0.76J 15J 3.4.1 3.4.1 6.8J TB-1a deep 13-Apr-18 2.1J 13J 3.1J 1.4.1 0.28J 13 TB-1a deep 24-Oct-18 13J 5.2.1 1.6J 6.5J TB-1a deep 24-Apr-19 13J 29 15J 3.9J TB-1a deep 5-Nov-19 1.7J 23 0.66 2.4.1 5.0 0.64J 2.8J 4.1J 38B TB-1a deep 6-Apr-20 1.5J 24 0.29J 2.8.1 3.6.1 0.61J 2.9J 65 TB-1a deep (dup) 6-Apr-20 1.91 23 0.27J 21 3.7.1 0.55J 3.5J 70 TB-1a deep 14-Oct-20 2.2 27 0.44J 2.0.1 2.4.1 0.99J 2.4J 3.1J 82 TB-1a deep 31-Mar-21 0.53J 17 0.28J 4.8.1 2.3.1 3.4J 25 TB-1a deep 9-Nov-21 14 2.1J 0.25J 5.6 TB-1a deep 29-Mar-22 31 0.46J 2.3.1 3.2.1 0.68J 2.4J 4.1 71 MW-33 25-Apr-12 112 0.208J 44.4 15.1 37 6.44J 20.2J 0.917J 72.1 102 MW-33 17-Apr-13 70J 0.3.1 17 5.1 13 2J 7J 34 33 MW-33 15-Apr-14 40J 5.1 0.6J 1.1 2J 8J 9.113 MW-33 29-Apr-15 50J 0.07J 7.1 1.1 3.1 0.4J 3J 8J 15 MW-33 21-Apr-16 0.5J 100J 0.1J 17 4.1 12 2J 7J 21J 35 MW-33 20-Apr-17 29J 5.1J 1.5.1 5.9J 7.4.1 MW-33 13-Apr-18 28J 5.3.1 3.1 6.3.1 MW-33 24-Apr-19 59J 4.3.1 1.6.1 1.7J 4.OJ 4.8.1 MW-33 8-Apr-20 71 0.25J 0.66 41 8.1 22 2.7 14 42 77 MW-33 (dissolved) 8-Apr-20 NA NA NA NA NA 3.8.1 NA NA NA NA NA NA NA NA MW-33 31-Mar-21 56 7.3 1.7J 3.7J 5.2.1 MW-33 29-Mar-22 1 31 1 3.2.1 1 4.1J 3.2.1 MW-34 26-Apr-12 0.261J 184 1.27 25.4 4.77.1 23.8E 8.3J 0.255 13.2J 37.4 53.7 MW-34 17-Apr-13 560 5 0.3J 75 17 90 21 0.45 49J 0.1 239 282 MW-34 15-Apr-14 110 0.3J 0.2J 3.1 1.1 0.8J 0.25 2J 3J 16B MW-34 29-Apr-15 220 1.5 0.2J 24 5.1 24 5J 0.33 15J 0.11 47 76 MW-34 21-Apr-16 150 0.5J 9.1 2.1 5.1 0.8J 0.17J 5J 0.08J13 2J 32 MW-34 20-Apr-17 84J 0.29.1 4.4.1 1.4.1 0.25 2.OJ 1.5J 13 MW-34 13-Apr-18 130 0.63J 8.6.1 1.8.1 6.8.1 1.2J 1.1 5.2J 7.1J 21 MW-34 (dissolved) 13-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-34 25-Apr-19 170 0.62J 0.21.1 14 2.5.1 10 1.9J 0.30 6.9J 14J 30 MW-34 (dissolved) 25-Apr-19 NA NA NA NA NA 2.0.1 1.7.1 NA NA NA NA NA NA NA NA MW-34 7-Nov-19 190 1.7 0.9613 31 4.OJ 26 5.0 1.6 16 1.5J 0.2013J 37 49 MW-34 (dissolved) 7-Nov-19 NA NA NA NA NA 4.2J NA NA 0.49 NA NA NA NA MW-34 9-Apr-20 120 0.47 0.31J 13 1.91 7.6 1.4 0.28 6.4 7.0 35 MW-34 (dissolved) 9-Apr-20 NA NA NA NA NA 2.9J NA NA NA NA NA NA NA NA MW-34 15-Oct-20 89 0.26J 4.1J 1.3J 2.6J 13 MW-34 31-Mar-21 240 0.91 0.30J 28 7.9 13 2.4 0.13J 11 16 36 MW-34 (dissolved) 31-Mar-21 NA NA NA NA NA 6.2 NA NA NA NA NA NA NA NA NA MW-34 11-Nov-21 83 0.29J 3.4J 1.7J 0.18J 2.6J 9.2.1 MW-34 30-Mar-22 150 1.11 191 12J 1.9J 0.17J 8.8J 17J 24J MW-34 (dissolved) 30-Mar-22 NA NA NA NA I NA I 3.6J I NA I NA I NA NA NA I NA I NA I NA I NA NA CDIN Page 12 of 30 June 2022 Smith Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-34d 25-Apr-12 0.575J 32.5.1 8.02J 5.86JB 2.66J 1.57J 7.83.1 MW-34d 16-Apr-13 0.6J 20J 0.1J 0.3.1 4.1 0.1J 1JB 0.6J 0.7J 2.113 MW-34d 15-Apr-14 0.4J 0.5J 20J 0.1J 0.2.1 4.1 0.09J 2.1 0.5J 4J 11B MW-34d 28-Apr-15 0.8J 20J 0.1J 0.3.1 5.1 0.08J 1.1 0.5J 0.05J 0.5J 6.1 MW-34d 21-Apr-16 180 0.8J 0.1J 15 3.1 12 21 0.191 81 1.1 0.1.113 12J 35 MW-34d 20-Apr-17 20J 0.14J 6.4.1 0.073J 2.0J 3.0.1 MW-34d 11-Apr-18 20J 0.15J 12 MW-34d 23-Apr-19 21.1 6.5.1 0.46 MW-34d 6-Nov-19 25 1.8 8.7 4.3.1 0.90J 0.2013 1.4J 19 MW-34d 8-Apr-20 1.2J 27 1.7 7.9 4.9.1 0.90J 1.5J 19 MW-34d 15-Oct-20 3.1 28 0.82 7.1 1.6.1 22 MW-34d 31-Mar-21 26 2.2 9.8 2.9.1 0.27J 12 MW-34d 10-Nov-21 0.60J 25 0.22J 0.20J 6.8 0.111 2.6J MW-34d 29-Mar-22 27 0.16.11 1 9.7 MW-35 25-Apr-12 51.3J 0.616.1 3.96.1 2.36.1 5.67.1 3.10J 11.1 17.8 MW-35 17-Apr-13 60J 0.8J 0.1J 5.1 2.1 7.1 2J 4J 16J 12B MW-35 16-Apr-14 60J 1.0.1 0.3.1 6.1 3.1 8.1 2J 4J 22J 26B MW-35 29-Apr-15 70J 1.0 0.1J 7.1 4.1 9.1 2J 0.02J 5J 0.06J 22J 20 MW-35 20-Apr-16 50J 0.7J 4.1 2.1 5.1 11 3J 111 12 MW-35 20-Apr-17 38J 0.39.1 2.3.1 6.5J 2.4.1 5.0J 3.7J 3.9J 66 MW-35 13-Apr-18 29J 0.28.1 0.24.1 1.5.1 3.3.1 0.48J 32 MW-35 24-Apr-19 38J 0.41.1 2.1J 1.6.1 1.6.1 0.38J 1.3J 3.1J 14 MW-35 9-Apr-20 36 0.4 2.2.1 1.6.1 1.9.1 0.48J 1.81 33 MW-35 31-Mar-21 36 0.40 4.1J 0.61J 3.3J 11 MW-35 29-Mar-22 38 0.51 1 1 1.6.1 4.4.1 1 0.83J 1.5J 1.4J 4.7J 24 MW-36 25-Apr-12 64.7.1 7.90J 2.61.1 9.44.1 4.33J 12.5J 12.1 MW-36 23-Oct-12 216 68.8 18.8 84 8.62J 29.3J 0.420J 91.7 72 MW-36 (dup) 23-Oct-12 73.7.1 11.6 3.49J 13.4 6.09J 0.121J 16.8J 18.4 MW-36 17-Apr-13 50J 0.1J 6J 2J 6.1 0.5J 4J 8J 12B MW-36 16-Oct-13 0.61 60J 0.2.1 7J 21 8.1 0.6J 4J 0.05J 101 4.113 MW-36 16-Apr-14 90J 0.3.1 19 51 23 2J 91 0.11 33 32B MW-36 12-Nov-14 130 0.6J 32 91 39 3J 15J 0.1 40 46 MW-36 30-Apr-15 0.61 100J 0.3.1 24 7J 27 2J 0.02J 11J 0.2J 29 27 MW-36 15-Oct-15 130 0.7J 38 10 46 3J 0.05J 16J 0.1 37 41 MW-36 20-Apr-16 70J 0.3.1 13 31 15 11 6J 0.11 111 17 MW-36 13-Sep-16 62J 0.24.1 0.047J 11 3.0J 10B 0.88J 5.3J 0.088J 14J 16 MW-36 20-Apr-17 40J 2.8.1 2.9.1 1.8J 4.4J 11 MW-36 22-Sep-17 70J 0.32.1 16 3.3.1 18 1.3J 6.6J 20J 16 MW-36 (dissolved) 22-Sep-17 NA NA NA NA NA NA NA NA NA NA NA NA 4.9J NA MW-36 13-Apr-18 54J 0.29.1 5.4.1 3.3.1 0.75J 1.8J 3.2J 4.01 MW-36 (dissolved) 13-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-36 25-Oct-18 80J 0.20J 27 4.8.1 20 1.6J 12J 25 25 MW-36 (dissolved) 25-Oct-18 NA NA NA NA NA 2.3.1 NA NA NA NA NA NA NA NA MW-36 25-Apr-19 180 0.33J 57 11 55 4.3J 18J 0.31J 55 59 MW-36 (dissolved) 25-Apr-19 NA NA NA NA NA 3.8J NA NA NA NA NA NA NA MW-36 7-Nov-19 81 0.40 21 4.5J 23 1.5 0.21 8.2 0.1713J 23 25 MW-36 (dissolved) 7-Nov-19 NA NA NA NA NA 1.5J NA NA NA NA NA NA NA NA MW-36 9-Apr-20 120 0.31J 35 7.8 35 2.8 14 0.23J 35 33 MW-36 (dissolved) 9-Apr-20 NA NA NA NA NA 1.91 NA NA NA NA NA NA 1.6 NA MW-36 15-Oct-20 51 4.81 3.8J 0.27J 2.6J 5.5 7.01 MW-36 31-Mar-21 65 21 2.81 12 0.97J 4.9J 14 12 MW-36 (dissolved) 31-Mar-21 NA NA NA NA NA 5.7 NA NA NA NA NA NA NA NA NA NA M W-36 11-Nov-21 46 1.31 2.4J 6.61 MW-36 30-Mar-22 83 17J 19.1 7.4J 20J 21J MW-36 (dissolved) 30-Mar-22 NA NA I NA I NA I NA NA I NA I NA I NA I NA NA NA I NA I NA NA Smith Page 13 of 30 June 2022 Table 4a Detected Groundwater Constituents - Metals March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 Notes: 1. All units are in micrograms per liter (parts per billion). 2. * - The upper tolerance limits (UTL) were calculated as part of the North Wake Unlined Alternate Source Demonstration and were approved by the Solid Waste Section on August 17, 2020. 2. dup - Duplicate Sample 3. (3) - Monitoring wells were not sampled due to an insufficient volume of water in the well. 4. J - Indicates the analytical result is an estimated concentration between the method detection limit and the limit of quantitation. 5. S - Matrix spike/matrix spike duplicate failure 6. B - The analyte concentration detected in the method blank was greater than the method detection limit. 7. D - Dilution greater than 1 8. Monitoring wells MW-28, -28d, -33, and -35 are sampled yearly during the spring event. 9. Dissolved metal samples were collected to evaluate the influence of turbidity on total metal concentrations. 10. NA - Not Analyzed Concentration exceeds the 15A NCAC 02L .0202 (North Carolina 2L) or UTL. Indicates the result is below the detection limit. Smith Page 14 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 15 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 16 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 17 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 18 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 19 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 20 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 21 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 22 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 23 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 24 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 25 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 26 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 CDNI Smith Page 27 of 30 June 2022 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 Notes: 1. All units are in micrograms per liter (parts per billion). 2. dup - Duplicate Sample 3. lal - Monitoring wells were not sampled due to an insufficient volume of water in the well. 4. J - Indicates the analytical result is an estimated concentration between the method detection limit and the limit of quantitation. 5. 8-The analyze concentration detected in the method blank was greater than the method detection limit. 6. L- Laboratory control spike/laboratory control spike duplicate failure 7. H -The analyze was out of holding time. 8. (--) - Not Analyzed. 1,4-Dioxane was removed from the sampling program for all wells on June 26, 2019, with the exceptions of MW-6, -8, and -9, due to two consecutive non -detect events. Concentration exceeds the 15A NCAC 02L.0202 (North Carolina 2L). - Indicates the result is below the detection limits. Smith Page 28 of 30 June 2022 Table 4c Detected Surface Water Constituents - Metals and Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 Smith Page 29 of 30 June 2022 Table 4c Detected Surface Water Constituents - Metals and Volatile Organic Compounds March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 Notes: 1. All units are in micrograms per liter (parts per billion). 2. Izl - A Standard for total chromium has not been established. The value provided is for chromium (III). 3. NS - No Standard 4. (°) - North Carolina 15A NCAC 02B (NC 2B) Fish Consumption Standard 5. Isl - North Carolina In -Stream Target Value Freshwater Aquatic Life Standard 6. I61- NC 2B Freshwater Aquatic Life Standard 7. (') - North Carolina In -Stream Target Value Fish Consumption Standard 8.1 - Indicates the analytical result is an estimated concentration between the method detection limit and the limit of quantitation. 9. B - The analyte concentration detected in the method blank was greater than the method detection limit. Concentration exceeds the NC 2B or In -Stream Target Value Freshwater Aquatic Life or Fish Consumption Standard for Class C Waters -July 2021 Indicates the result is below the detection limit. Smith Page 30 of 30 June 2022 Table 5 Constiuents Exceeding Standards March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 ToleranceMonitoring March 2022 Parameters Exceeding the North Carolina 2L, Monitoring March 2022 Parameters Exceeding the North Carolina 2L, Facility Permit Number Well Code Interim Maximum Allowable Concentration, or Upper Interim Maximum Allowable Concentration, or Upper Tolerance 9209-MSWLF-1984 MW-11 None MW-28 None 9209-MSWLF-1984 MW-11d None MW-28d None 9209-MSWLF-1984 MW-5R Cobalt* MW-29d None 9209-MSWLF-1984 MW-6 Cobalt*, 1,4-Dioxane MW-30 Dry 9209-MSWLF-1984 MW-6d None MW-31 None 9209-MSWLF-1984 MW-7 Cobalt* MW-31d None 9209-MSWLF-1984 MW-8 Cobalt*, 1,4-Dioxane, Vinyl Chloride MW-32 None 9209-MSWLF-1984 MW-8d None TB-1a Dry 9209-MSWLF-1984 MW-9 Cadmium, 1,4-Dichlorobenzene, 1,2-Dichloroethane, 1,4-Dioxane, Vinyl Chloride TB-1a deep None 9209-MSWLF-1984 MW-10 None MW-33 None 9209-MSWLF-1984 MW-10d None MW-34 Chromium, 1,1-Dichloroethane, Methylene Chloride, Tetrachloroethene 9209-MSWLF-1984 MW-22 Cobalt* MW-34d None 9209-MSWLF-1984 MW-23 None MW-35 Tetrachloroethene 9209-MSWLF-1984 MW-23d None MW-36 Chromium, Vinyl Chloride 9209-MSWLF-1984 MW-24 None MW-36d None Notes: 1. * -Upper Tolerance Limit -Calculated as part of the North Wake Unlined Alternate Source Demonstration and were approved by the Solid Waste Section on August 17, 2020. 2. Bold - Indicates a J flag detection in which the analytical result is an estimated concentration between the method detection limit and the limit of quantitation. 3. MW-30 and TB-1a were dry during the March 2022 sampling event. CDM Smith Page 1 of 1 June 2022 Table 6 Geochemical Data March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - 9209-MSWLF-1984 MW-5R 24-Apr-12 192.5 5.72 1.48 <2 <70 -- <0.43 <0.2 <0.54 -- -- 2.2J 10.0 1.1 110 3.41 <0.01 321D <0.046 <0,04 <0.24 <0.87 <0.62 <O.048 <0.057 <0.061 o 2.4 MW-5R 22-Oct-12 96.1 6.20 2.22 <2 13 -- 1.64 <0.2 <0.54 -- -- 3.118 4.3J 1.4 190 51 <0.01 375D <0.046 <0.031 <0.031 <0.078 <0.095 <0.052 <0.063 <0.01 9.1 MW-5R 17-Apr-13 110.1 6.46 0.73 <4 <16 -- 0.31J <0.061 <0,069 -- -- 1.4 9.07 1.4 135 2.11 <0.4 180 0* <0.5 <1 <0.5 <0.5 <0.25 0.381 MW-5R 16-Oct-13 132.5 6.08 1.88 <4 <16 -- 2.3 <0.061 <0,069 -- -- 1.70 9.90 1.1 184 2.98 <0.4 210B 0.2* <0.5 <1 <0.5 <0.5 <0.25 0.82 MW-5R 16-Apr-14 139.7 5.48 3.09 (1) <16 -- <1.3 <0.61 <0.069 -- -- 1.4 9.35 0.7J 11.5 1.3 <0.4 180 0* <0.5 <1 <0.5 <0.5 <0.25 1.2 MW-5R 12-Nov-14 -116.7 6.74 1.41 (1) <16 -- 1.11 <0.61 <0.069 -- -- 2.1 6.25 <0.09 211 2.98 0.4JB 130 0* <0.5 <1 <0.5 <0.5 <0.25 11 MW-5R 30-Apr-15 14.4 5.39 2.41 <2 <16 -- <0.30 <0.61 <0.069 -- -- 1.6 8.00 0.9J 62.1 1.5 <0.4 120 0* <0.5 <1 <0.5 <0.5 <0.25 2.8 MW-5R 15-Oct-15 156.1 6.38 2.12 <2.0 <16 -- 1.9 <0.061 <0.069 -- -- 2.8 0.137 1.0 272 9.5 0.5J 110 0* <0.50 <1.0 <0.50 <0.50 <0.020 2.4 MW-5R 21-Apr-16 116.7 5.54 1.36 <2.0 <16 -- <0.30 <0.061 <0.069 -- -- 1.6 3.65 0.9J 39.1 1.1 <0.4 110 0.5* <0.50 <1.0 <0.50 <0.50 <0.020 14.0 MW-5R 14-Sep-16 109.2 5.88 1.99 <2.0 <10 -- 4.2J <SO <SO -- -- 2.6 1.8 0.56) 220 3.48 <1.0 430 0.5* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 3.9 MW-5R 20-Apr-17 94.2 6.29 1.30 <2.0 <10 -- 3.6 <SO <10 -- -- 2.6 1.6 1.1 200 1.1 <1.0 350 0* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 1.6 MW-5R 20-Sep-17 -29.0 6.60 2.58 <2.0 55 -- 4,100D <10 <10 -- -- 220D 0.23 0.67 350 11D <2.5 990 5.0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 0.26 3.0 MW-5R 11-Apr-18 40.9 5.90 1.56 <2.0 <10 -- <10 <SO <10 -- -- 2.5 3.6 0.96) 100E 2.2 <1.0 130 0* <.0.10 <0.10 <0.20 <0.20 <0.10 <0. 10 <0.10 2.7 MW-5R 24-Oct-18 52.8 6.33 0.24 <2.0 <20 -- 11B <10 <10 -- -- 4.6 0.064 1.6 260 2.6 <1.0 300 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0. 10 <0.10 4.6 MW-5R 22-Apr-19 179.2 4.83 2.27 <2.0 <20 -- <10 <SO <10 -- -- 1.8 5.1 <1.0 <20 0.54J <1.0 71 0* <0.10 <0.10 <0.20 <0.20 <0. 10 <0. 10 <0.10 <1.0 MW-5R 6-Nov-19 229.2 6.11 1.98 <2.0 <20 -- 17B <SO <10 -- 8,900 6.6 0.23 1.1 120 4.4 <1.0 470 0* <0.10 <0.10 <0.20 <0.20 <0. 10 <0. 10 <0.10 2.5 MW-5R 4-Feb-20 179.2 4.83 2.27 -- 13,OOOC 2,300 1,700D <50 <50 30,000 6,300 -- 0.23 -- 150 <1.0 -- 4,500 2.5* 520.0 49.0 6.5 3.7 4.3 230.0 1.0 -- MW-5R 8-Apr-20 37.1 5.26 0.82 >8211" 2,800D 860 3100 <1O <1O 85,000 6,300 4.9 <0.020 760D 410 <1.0 1.1 4,000 2.5* 760d1,.' 87d 8.8d <0.20 23d 230d 7.6d 12 MW-5R 30-Jul-20 -55.9 6.04 1.21 1,200D 1,200D 930 8,500D <50 <50 120,000 6,900 -- <0.020 -- -- <1.0 -- 1,100 3.0* 250.0 34.0 9.8 <5.0 5.6 38.0 7.3 -- MW-5R 15-Oct-20 -28.2 6.16 0.53 >1001"1 920 730 4,400BD <10 <10 120,000 7,600 8.41D 0.12BJD 210D 390 <10 <1.0 970 5.0* 180.0 7.71 <1.2 <1.1 <1.1 7.71 <1.2 33 MW-5R 31-Mar-21 -76.2 6.16 0.13 100101 280 290 7,000BD <10 <10 84,000 5,000 3.41D 0.027JD 58 270 15.0 <1.0 750 4.5* 63 <0.58 <0.58 <0.53 <0.56 4.31 <0.60 2.9 MW-5R 11-Nov-21 -45.5 6.53 0.42 21(121 170 350 5,900E 110 110 88,000 5,500 6.3D <0.10 41.7 300 15.0 <1.0 490 5.0* 5.7 <0.058 <0.058 1.1 <0.056 <0.053 <0.060 1.7J MW-5R 30-Mar-22 -42.3 6.38 0.82 16 59 170B 3,000B <2.5 <2.5 41,000 3,500 2.3 0.020 12 170 <13 <3.0 320 6.5* 0.46) <0.058 0.0621 0.381 <0.056 <0.053 <0.060 1.41 MW-6 24-Apr-12 168.6 5.85 2.14 <2 32 -- 5,660D <0.2 <0.54 -- -- 97 0.251 4.4 190D 3.51 <0.01 549D <0.046 <0.04 <0.24 <0.87 <0.62 0.56 1.7 <0.061 2.6 MW-6 22-Oct-12 -134.6 6.34 4.33 <2 100 -- 732D <0.2 <0.54 -- -- 160BD <0.025 21 430D 11J 0.029 725D 3.6 <0.031 <0.031 <0.078 26 <0.052 30 <0.01 5.9 MW-6 17-Apr-13 -158.3 6.25 0.91 <4 <16 -- 16 <0.061 <0.069 -- -- 54.4 0.181 3.5 105 2.82 <0.4 110 1.4* <0.5 <1 <0.5 <0.5 <0.25 0.76 MW-6 16-Oct-13 12.9 6.32 1.81 <4 40 -- 45 <0.061 <0.069 -- -- 93 0.161 5.2 136 2.63 <0.4 98B 5.4* <0.5 <1 <0.5 <0.5 <0.25 0.93 MW-6 16-Apr-14 43.1 5.99 1.81 (1) <16 -- 51 <0.061 <0.069 -- -- 40.3 0.42 1.6 40.2 1.5 <0.4 69 0.5* <0.5 <1 <0.5 <0.5 <0.25 1.3 MW-6 12-Nov-14 -121.4 6.81 0.87 (1) 74 -- 1,400 <0.061 <0.069 -- -- 184 0.091 14.4 607 47.3 <0.4 180 1.5* <0.5 <1 <0.5 <0.5 <0.25 7.3 MW-6 30-Apr-15 -52.3 6.05 2.01 <2 <16 -- 23 <0.061 <0.069 -- -- 50.9 0.161 2.6 192 5.9 <0.4 95 0.5* <0.5 <1 <0.5 <0.5 <0.25 2.5 MW-6 14-Oct-15 58.9 6.68 2.39 <2.0 60 -- 0.621 <0.061 <0.069 -- -- 208 0.017 14.7 422 19.7 0.4 UX 87 0* 2.1 <1.0 <0.50 <0.50 <0.020 2.4 MW-6 20-Apr-16 38.7 6.53 1.53 <2.0 <12 -- 0.321 <0.061 <0.069 -- -- 58.5 0.37 2.3 164 4.1 <0.4 62 1.5* <0.50 <1.0 <0.50 <0.50 0.151 12 MW-6 14-Sep-16 11.0 6.42 1.40 <2.0 44 -- 3.7J <10 <10 -- -- 210D 0.037 11 390 13D <1.0 470 1.5* <0.10 <0.30 <0.20 <0.20 <0.10 <0.10 <0.10 3.8 MW-6 20-Apr-17 119.3 6.70 2.16 <2.0 22 -- 4.21 <10 <10 -- -- 130 0.46 6.4 250 11 <1.0 350 0* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 22 MW-6 21-Sep-17 -59.0 7.54 2.87 <2.0 31 -- <10 <SO <SO -- -- 140 0.069 30 430 19 <1.0 520 2.0* <0.10 <0.30 <0.20 <0.20 <0.10 <0.10 <0.10 3.4 MW-6 12-Apr-18 13.0 6.34 1.74 <2.0 15 -- 140 <30 <30 -- -- <10 1.5 5.1 140B 5.5 <1.0 150 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 3.6 MW-6 24-Oct-18 49.6 6.64 0.60 3.6 37 -- 1,900B <10 <10 -- -- 160 <0.020 12 590 20 <1.0 590 1.0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 10 MW-6 22-Apr-19 100.4 6.12 0.51 5.3 <20 -- 1,800 <SO <SO -- -- 74 1.5 2.8 220 4.1 <1.0 450 1.0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 <1.0 MW-6 6-Nov-19 39.3 6.38 1.11 <2.0 33 -- 56B <10 <10 1 180 0.48HD 14 410 7.7 <1.0 750 1.0* <0.10 <0.10 0.76 <0.10 <0.10 <0.10 <0.10 3.0 MW-6 7-Apr-20 79.2 5.85 3.66 <2.0 <20 -- 42B <SO <SO -- -- 78 0.57 1 2.5 150 5.4 <1.0 220 0.5* <0.10 <0.10 <0.20 <0.10 <0.10 <0.10 <0.10 4.3 MW-6 15-Oct-20 -29.1 6.06 2.08 <2.0 22 -- 260 <10 <10 -- -- 120D 1.8BD 7.6 210 7.6JD <1.0 350 2.0* 3.21 <0.58 <0.58 <0.53 <0.56 0.54J <0.60 <0.49 MW-6 31-Mar-21 117.4 5.43 1.75 <2.0 <20 -- 100 <10 <10 -- -- 68 0.92 2.7 140 3.7 <1.0 350 0* 0.241 <0.058 <0.056 <0.053 <0.056 <0.053 <0.060 <0.98 MW-6 10-Nov-21 74.8 6.52 2.60 <2.0 24 -- 83 <10 <10 -- -- 130 18EHD 1.1 310 13D <1.0 310 0.5* 2.61 <0.58 0.591 <0.53 <0.56 <0.53 <O.60 1.11 MW-6 29-Mar-22 239.0 6.35 1.44 <0.18 245 3.1B1 <2.5 <2.5 120 7.1H 7.4 410 6.8 <1.0 520 0* <1.2 <0.58 0.611 <0.53 <0.56 <0.53 <0.60 0.75J MW-8 24-Apr-12 161.7 5.64 1.67 <2 <SO -- 1,870D <0.2 <0.54 -- -- 12 0.191 0.95J 74 2.61 <0.01 324D <O.046 <0.04 <0.24 <0.87 <0.62 <O.048 <0.057 <0.061 2.0 MW-8 22-Oct-12 128.4 5.86 2.11 <2 <30 -- 477D <0.2 <0.54 -- -- 14B 0.321 0.8201 77 3.11 <0.01 323D <O.046 <0.031 <0.031 <0.078 1.1 <0.052 <0.063 0.011 9.8 MW-8 17-Apr-13 96.8 6.23 0.48 <4 <16 -- 520 0.141 0.11 -- -- 16.9 0.2J 1.4 86.8 1.49 <0.4 180 0.9* <0.5 <1 <0.5 <0.5 <0.25 0.72 MW-8 16-Oct-13 146.8 5.79 1.74 <4 <16 -- 430 0.111 <0.069 -- -- 19.7 0.181 1.5 86.8 1.57 <0.4 200B 0.8* <0.5 <1 <0.5 <0.5 <0.25 0.85 MW-8 16-Apr-14 122.9 5.79 0.19 (1) <16 -- 180 <0.60 <0.069 -- -- 23.7 0.181 1.3 87.7 1.7 <0.4 230 0* <0.5 <1 <0.5 <0.5 <0.25 1.4 MW-8 12-Nov-14 -94.6 6.09 0.79 (1) 20 -- 320 0.13J 0.17J -- -- 29.4 0.121 1.5 95.5 2.2B 0.4JB 160 0* <0.5 <1 <0.5 <0.5 <0.25 17 MW-8 30-Apr-15 22.5 5.62 1.85 <2 17J -- 160 <0.061 0.111 -- -- 44.0 0.111 2.8 132 2.5 <0.4 180 0* <0.5 <1 <0.5 <0.5 <0.25 4.1 MW-8 15-Oct-15 113.1 5.93 1.63 <2.0 17J -- 150 <0.061 <0.069 -- -- 44.9 0.0071 2.3 114 4.2 0.5J 130 0* 0.681 <1.0 <0.50 <0.50 <0.020 2.0 MW-8 21-Apr-16 81.5 5.99 1.86 <2.0 <12 -- 110 <0.061 <0.069 -- -- 39.6 <0.04 2.6 123 2.4 <0.4 150 0* <0.50 <1.0 <0.50 <0.50 <0.020 15 MW-8 14-Sep-16 116.9 5.75 1.77 <2.0 6.71 -- 640 <SO <SO -- -- 45 0.021 1.9 120 2.3B <1.0 370 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 3.8 MW-8 20-Apr-17 113.7 5.97 1.25 <2.0 8.31 -- 180 <10 <10 -- -- 37 0.069 1.8 110 0.98J <1.0 300 0* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 1.6 MW-8 20-Sep-17 154.0 6.41 1.78 <2.0 9.3 -- 150 <10 <10 -- -- 44 0.055 2.4 120 1.5 <1.0 320 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 4.4 MW-8 12-Apr-18 25.6 5.79 1.21 2.2 <10 -- 150 <10 <10 -- -- 45 0.035 2.2 140B 1.2 <1.0 150 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0. 10 <0.10 2.8 MW-8 24-0ct-18 68.9 5.87 0.10 <2.0 <20 -- 200B <10 <30 -- -- 49 <0.020 2.8 130 2.2 <1.0 180 0.5* <0.10 <0.10 <0.20 <0.20 <0.10 <0. 10 <0.10 3.4 MW-8 22-Apr-19 55.7 5.94 1.29 <4.0 <20 -- 350 <10 <10 -- -- 78 0.042 5.1 170 1.6 <1.0 770 1.0* <0.10 0.10 <0.20 <0.20 <0.10 <0.10 <0.10 <S.0 MW-8 6-Nov-19 116.9 6.07 0.49 <2.0 71 -- 410B <10 <30 -- -- 29 0.016J 3.6 110 2.0 <1.0 340 0.5* 0.14 <0.10 <0.20 <0.20 <0.30 <0.30 <0.10 1.5 MW-8 7-Apr-20 68.9 5.84 3.80 <2.0 <20 -- 76 <30 <30 -- -- 43 0.028 1.8 130 2.1 <1.0 170 1.0* <0.10 <0.10 <0.20 <0.20 <0.30 <0.30 <0.10 2.1 MW-8 15-Oct-20 -19.3 5.86 0.49 <2.0 <20 -- 590 <10 <30 -- -- 81 <0.020 5.1 150 1.2 <1.0 240 1.5* 0.35J <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 0.49J MW-8 31-Mar-21 58.0 5.75 0.23 <2.0 <20 -- 150 <10 <30 -- -- 130 <0.10 3.4 210 1.0 <1.0 280 1.0* 1.7J <0.29 <0.29 <0.26 <0.28 <0.26 <0.30 2,1 MW-8 30-Nov-21 67.1 6.19 1.05 <2.0 <20 -- 490 <10 <10 -- -- 70 <0.020 4.2 170 1.9 <1.0 250 1.0* 0.211 <0.058 0.0771 <0.053 <0.056 <0.053 0.0801 2.1 MW-8 29-Mar-22 51.1 6.03 2.36 <0.18 <20 1 150B <2.5 <2.5 76 0.35HJD 4.5 1 180 1 1.5 1 <1.0 1 340 1 0* 1 0.211 1 <0.058 1 <0.0581 0.421 <0.056 <0.053 1 <0.0691 0.921 Csp_tl Page 1 of 3 June 2022 Table 6 Geochemical Data March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - 9209-MSWLF-1984 MW-9 o o 25-Apr-12 94.8 5.95 3.11 5.4 34 75 75 -- 2,810D <0.2 1.591 -- -- 18 0.0791 6.1 250D 2.81 <0.01 503D 7.8 o <0.24 <0.87 <0.62 <0.048 1.7 <0.061 -- MW-9 23-Oct-12 83.4 6.72 8.77 <2 61 -- 5.47 <0.2 <0.54 -- -- 17B <0.025 3.2 120 8.81 <0.01 16.6 <0.230<0.031 <0.078 <0.095 <0.052 0.840 0.017MW-9 17-Apr-13 91.3 6.88 6.84 3.1 22 -- 8.5 <0.061 <0,069 -- -- 17.1 <0.03 3.5 130 7.42 <0.4 10 2.1* <1 <0.5 <0.5 <0.25MW-9 16-Oct-13 165.7 6.88 7.89 <4 28 -- 0.53J <0.061 <0,069 -- -- 20.4 0.171 2.9 117 5.60 <0.4 27B 0* 7<0.031 <1 <0.5 <0.5 <0.25MW-9 16-Apr-14 160.2 6.44 3.69 (1) 17J -- 17 <0.061 <0,069 -- -- 18.5 0.151 3.1 127 4.8 <0.4 39 0* <1 <0.5 <0.5 <0.25MW-9 12-Nov-14 33.5 6.80 5.67 (1) 30 -- 1.8 <0.061 <0.069 -- -- 22.7 0.101 <0.09 136 3.98 0.4JB 28 0* <1 <0.5 <0.5 <0.25MW-9 29-Apr-15 20.6 6.57 9.69 2.8 17J -- 2.9 <0.061 <0.069 -- -- 19.2 <0.03 3.8 156 3.6 <0.4 27 0* <1 <0.5 <0.5 <0.25 -- MW-9 15-Oct-15 132.2 6.65 4.66 6.5 <16 -- <0.30 <0.061 <0.069 -- -- 25.4 0.040 2.0 171 5.4 <0.4 53 0* <0.50 <1.0 <0.50 <0.50 <0.020 -- MW-9 20-Apr-15 75.9 6.81 5.40 <2.0 <12 -- 7.8 <0.061 <0.069 -- -- 18.2 0.051 1.7 182 3.4 <0.4 46 0* <0.50 <1.0 <0.50 <0.50 <0.020 -- MW-9 13-5ep-16 151.7 6.72 7.15 <4.0 8.0J -- - - - -- -- 25 0.052 1.6 200 3.8 <1.0 - 1.0* - - - - - -- MW-9 19-Apr-17 130.8 6.93 7.28 <2.0 <10 -- 6.1BJ <SO <10 -- -- 24 0.0096) 1.8 210 2.1 <1.0 240 1.0* <1.o <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 -- MW-9 21-Sep-17 140.0 7.57 6.01 <2.0 <10 -- <10 <SO <10 -- -- 24 0.056 1.9 200 2.8 <1.0 220 1.0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-9 11-Apr-18 41.4 6.79 7.50 <2.0 <10 -- <10 <SO <10 -- -- 23 0.080 1.8 190B 2.2 <1.0 180 1.5* <0.10 <0.10 <0.20 <0.20 <0.10 <0. 10 <0.10 -- MW-9 25-Oct-18 51.1 7.07 8.83 2.6 <20 -- 6.9BJ <SO <10 -- -- 22 <0.020 2.2 210 2.5 1.5 190 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0. 10 <0.10 -- MW-9 25-Apr-19 102.7 6.46 1.63 <2.0 <20 -- 1,500 <SO <10 -- -- 11 <0.020 3.7 270 1.4 <1.0 680 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0. 10 <0.10 -- MW-9 5-Nov-19 105.4 6.50 1.55 <2.0 <20 -- 530B <30 <30 -- -- 30 <0.30 3.5 370 2.7 <1.0 990 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0. 10 <0.10 -- MW-9 7-Apr-20 37.1 6.11 0.86 2.4"" <20 -- 1,800B <10 <10 -- -- 31 0.0079J 4.4 430 3.2 <1.0 570 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-9 15-Oct-20 -36.7 6.12 0.76 7.4") 21 -- 1,400 <10 <10 -- -- 41 <0.020 6.0 440 2.0 <1.0 570 0* 0.5 <0.058 0.111 0.0601 <0.056 0.066J <0.060 -- MW-9 31-Mar-21 -4.4 6.01 0.19 4.3") 36 -- 1,800 <10 <10 -- -- 45 <0.10 9.4 490 0.611 <1.0 820 0* 0.27J 0. 14J <0.058 <0.053 <0.056 <0.053 <0.060 -- MW-9 10-Nov-21 -36.3 6.39 0.66 2.6"v) 29 -- 3,100EHD <30 I -- -- 53 <0.020 9.0 250 0.9881 3.0 750 0* 0.26) <0.058 <0.058 <0.053 <0.056 <0.053 0.0921 -- MW-9 30-Mar-22 -4.4 6.21 0.08 2.4 30 1,600B Q.5 <2.5 45 0.37HJC 9.1 550 5.0 <3.0 720 1.5* <0.12 <0.058 <0.058 0.0591 <0.056 <0.053 <0.060 MW-10 25-Apr-12 127.9 5.41 2.62 <2 30 -- 10,300D <0.2 <0.54 -- -- 3.5J <0.025 3.3 120 3.11 <0.01 832D 0.17 0.26 <0.24 0.59 0.17 <0.048 <0.057 <0.061 -- MW-10 23-Oct-12 99.2 5.68 2.94 <2 28 -- 8,220D <0.2 <0.54 -- -- 3.71B <0.025 3.6 120 2.41 <0.01 646D 0.083 0.087 <0.031 <0.078 <0.095 <0.052 <0.063 0.0111 -- MW-10 17-Apr-13 113.9 6.08 2.93 <4 <16 -- 920 <0.061 <0.069 -- -- 2.71 <0.03 1.5 132 0.75 <0.4 370 1.4* <0.5 <1 <0.5 <0.5 <0.25 -- MW-10 16-Oct-13 84.8 5.65 4.05 <4 19J -- 3,100 <0.061 <0.069 -- -- 2.74 <0.03 0.9J 117 0.73 <0.4 300B 1.8* <0.5 <1 <0.5 <0.5 <0.25 -- MW-10 16-Apr-14 68.9 5.71 3.11 (1) <16 -- 3,200 <0.061 <0.069 -- -- 3.4 <0.03 2.3 129 0.71 <0.4 400 1.5* <0.5 <1 <0.5 <0.5 <0.25 -- MW-10 12-Nov-14 10.9 5.84 1.81 (1) 27 -- 3,900 0.094J 0.111 -- -- 3.0 <0.03 2.5 147 1.1B <0.4 360 2.0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-10 29-Apr-15 30.6 5.56 2.82 3.1 <16 -- 1,300 <0.061 <0.069 -- -- 3.4 <0.03 3.0 184 0.91 <0.4 320 2.0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-10 14-Oct-15 89.3 5.74 2.44 5.6 <16 -- 1,200 <0.061 <0.069 -- -- 3.3 <0.002 1.0 140 <1.8 <0.4 250 1.5* 0.67J <1.0 <0.050 <0.50 <0.020 -- MW-10 20-Apr-16 30.9 5.79 2.34 6.5 16J -- 1,200 <0.061 <0.069 -- -- 3.4 <0.04 1.6 128 <0.06 <0.4 200 1.0* 0.57J <1.0 <0.20 <0.50 <0.020 -- MW-10 13-Sep-16 28.2 5.44 1.61 4.3 10 -- - - - -- -- 3.6 0.024 <1.0 160 <1.0 <1.0 - 4.5* - - - - - -- MW-10 19-Apr-17 125.9 5.74 3.39 8.3 <10 -- 4,800B <10 <10 -- -- 3.6 0.0141 1.2 160 <1.0 <1.0 720 3.0* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 -- MW-10 22-Sep-17 118.0 6.20 1.90 <2.0 <10 -- 1,100 <10 <10 -- -- 3.0 0.017 1.9 110 <1.0 <1.0 440 3.0* <0.10 <0.30 <0.20 <0.20 <0.10 <0. 10 <0.10 -- MW-10 11-Apr-18 44.1 5.60 0.71 <2.0 9.4J -- 750 <30 <30 -- -- 3.0 0.089 0.9 88B 0.43J <1.0 140 2.5* <0.10 <0.30 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-10 25-Oct-18 74.0 5.61 3.64 5.5 <20 -- 3,200 <10 <10 -- -- 3.2 <0.020 1.3 120 <1.0 <1.0 450 3.5* <0.10 <0.30 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-10 25-Apr-19 7.9 5.47 0.39 5.1"" <20 -- 4,200D <10 <10 -- -- 3.9 <0.020 2.9 130 <1.0 <1.0 1,300 3.0* 0.34 <0.30 <0.20 <0.20 <0.30 <0.10 <0.30 -- MW-10 5-Nov-19 44.3 5.85 0.80 5.4 <20 -- 4,300BD <10 <10 -- -- 3.5 0.0161 1.2 120 0.49J <1.0 770 3.0* <0.30 <0.30 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-10 7-Apr-20 22.3 5.50 0.42 4.8"" <20 -- 3,300D <10 <10 -- -- 3.8 0.0171 1.5 120 <1.0 <1.0 350 2.5* <0.30 <0.30 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-10 15-Oct-20 -33.9 5.64 2.61 3.8j1' <20 -- 1,600 <10 <10 -- -- 3.3 0.032B <1.0 88 <1.0 <1.0 210 3.0* 0.37J <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 -- MW-10 31-Mar-21 167.3 5.11 0.19 <2.0 <20 -- 18 <30 <30 -- -- 3.1 2.0 2.1 27 0.321 <3.0 220 2.5* 0.22) <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 -- MW-10 10-Nov-21 153.4 5.87 0.38 <2.0 <20 -- 350 <10 <10 -- -- 3.1 0.59 0.711 57 0.63B1 <1.0 130 2.5* 0.21) <0.058 0.20J <0.053 <0.056 <0.053 <0.060 -- MW-10 30-Mar-22 158.7 5.63 0.18 <0.18 <20 330 <2.5 <2.5 2.8 0.61 1 <1.0 1 75 1 0.59J <1.0 1 190 1 2.0* 1 <0.12 <0.058 1 <0.0581 0.063J <0.056 <0.053 <0.060 MW-11 25-Apr-12 112.2 5.47 6.22 <2 <30 -- <0.43 <0.2 <0.54 -- -- 3.11 0.0861 0.76) 22 1.71 <0.01 161D <0.046 <0.04 <0.24 <0.87 0.13J <0.048 <0.057 <0.061 -- MW-11 23-Oct-12 237.1 5.82 7.22 <2 13 -- <0.43 <0.2 <0.54 -- -- 3.71B 0.1501 1.5 27 2.11 <0.01 147D <0.046 <0.031 <0.031 <0.078 <0.095 <0.052 <0.063 <0.01 -- MW-11 17-Apr-13 102.3 5.94 5.73 <4 <16 -- <0.30 <0.061 <0.069 -- -- 2.62 0.23 1.1 33.1 0.69 <0.4 100 0.8* <0.5 <1 <0.5 <0.5 <0.25 -- MW-11 16-Oct-13 211.6 5.49 7.94 <4 <16 -- <0.30 <0.061 <0.069 -- -- 3.16 0.26 0.7J 34.8 0.66 <0.4 82B 0.4* <0.5 <1 <0.5 <0.5 <0.25 -- MW-11 16-Apr-14 198.8 5.62 5.63 (1) 34 -- 0.59 <0.061 <0.069 -- -- 3.4 0.36 0.5J 38.9 0.71 <0.4 110 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-11 12-Nov-14 116.3 5.80 4.68 (1) 57 -- <0.30 <0.061 <0.069 -- -- 4.1 0.46 0.81 36.4 0.9JB 0.5JB 82 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-11 30-Apr-15 20.1 5.52 7.18 <2 <16 -- <0.30 <0.061 <0.069 -- -- 3.9 0.43 0.9J 35.8 0.9JB <0.4 82 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-11 15-Oct-15 196.8 5.91 5.70 <2.0 <16 -- <0.30 <0.061 <0.069 -- -- 3.6 0.480 0.3J 34.9 <1.8 <0.4 66 0* <0.50 <1.0 <0.50 <0.50 <0.020 -- MW-11 21-Apr-16 135.3 5.72 5.75 <2.0 <12 -- <0.30 <0.061 <0.069 -- -- 4.0 0.53 0.5J 33.9 0.71 0.5JB 75 1.5* <0.50 <1.0 <0.50 <0.50 <0.020 -- MW-11 1-Sep-16 149.9 5.56 6.49 15 <10 -- - - - -- -- 5.1 0.81 <1.0 42 <1.0 <1.0 - 1.5* - - - - - -- MW-11 20-Apr-17 142.3 5.87 4.82 <2.0 <10 -- 2.7J <10 <10 -- -- 4.8 0.89 <1.0 36 <1.0 <1.0 150.0 0.5* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 -- MW-11 22-Sep-17 244.0 6.39 4.55 <2.0 <10 -- <30 <10 <10 -- -- 5.2 0.88 <1.0 47 <1.0 <1.0 130 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-11 13-Apr-18 46.3 5.71 5.74 <2.0 <30 -- <30 <30 <30 -- -- 5.4 0.89 <1.0 46B 0.27J <1.0 75 0* <0.10 <0.10 <0.20 <0.20 <0.30 <0. 10 <0.10 -- MW-11 25-0ct-18 44.6 6.02 5.97 <2.0 <20 -- 2.5BJ <10 <30 -- -- 5.9 0.95 <1.0 46 <1.0 <1.0 82 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0. 10 <0.10 -- MW-11 25-Apr-19 87.8 5.91 5.94 3.4"') <20 -- <10 <10 <Io -- -- 5.8 0.94 1.9 49 <1.0 <1.0 170 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-11 5-Nov-19 183.2 6.16 6.46 2.1 <20 -- <30 <10 <30 -- -- 5.5 0.90 <1.0 42 0.26J <1.0 230 0* 0.51 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-11 8-Apr-20 144.7 5.88 6.44 6.2"') <20 -- 3.2J <10 <10 -- -- 5.7 0.94 <1.0 44 0.31J <1.0 100 0* 0.16'la� <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-11 14-Oct-20 33.2 5.84 6.33 101" <20 -- 2.8BJ <10 <Io -- -- 5.7 0.88 <1.0 43 <1.0 <1.0 86 0* 0.43J <0.058 <0.058 <0.053 <0.061 <0.053 <0.060 -- MW-11 31-Mar-21 132.4 5.57 6.58 <2.0 <20 -- 42 <30 <30 -- -- 5.6 0.77 <1.0 38 <3.0 <1.0 110 0* 0.50J <0.12 <0.12 <0.11 <0.11 <0.11 <0.12 -- MW-11 11-Nov-21 982.0 6.07 7.33 <2.0 <20 -- <10 <10 <10 -- -- 5.1 0.71D <1.0 35 <1.0 <1.0 130 0* 0.24J <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 -- MW-11 30-Mar-22 257.8 5.69 4.71 <0.18 <20 <2.5 <2.5 <2.5 5.1 0.88 <1.0 42 1 <0.25 <1.0 1 180 1 0* 1 <0.12 <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 � t Page 2 of 3 June 2022 Table 6 Geochemical Data March 2022 Semi -Annual Sampling Event North Wake Unlined Landfill - 9209-MSWLF-1984 MW-34 o 75 6-Nov-19 195.8 5.63 1.52 <2.0 E <20 75 75 -- 260B <10 <10 -- 7,300 11 0.14 1.0 35 0.471 <1.0 330 0* 0.12 co 0.29 <0.20 <0.20 o <0. 10 0.21 <0.10 -- MW-34 4-Feb-20 157.2 5.15 1.25 -- <20 74 470 <10 <10 470 8,700 -- 0.20 -- 24 <1.0 -- 570 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-34 8-Apr-20 96.9 5.21 0.78 <2.0 <20 85 350 <10 <10 3,900 8,300 14 0.14 <1.0 40 0.50J 1.4 120 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW- 4 -Jul- 0 -1 .4 5. 0 0.1 -- <20 150 370 <10 <10 6,700 8,000 -- 0.10 -- -- <1.0 -- 110 0* <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 -- MW-34 15-Oct-20 -22.1 5.29 0.91 <2.0 <20 99 300 <10 <10 610 8,200 14 0.091E <3.0 36 <1.0 <1.0 120 0* 0.431 <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 -- MW-34 31-Mar-21 197.4 4.57 1.80 <2.0 <20 140 26 <30 <30 6,300 24,000 54 0.020 <3.0 <20 5.7 <3.0 190 0* 1.11 <0.29 <0.29 <0.26 <0.28 <0.26 <0.30 -- MW-34 11-Nov-21 194.1 5.63 0.39 <2.0 <20 77 310 <30 <30 1505 11,000 15D O.30D 0.651 35 1.5 <3.0 210 0* 0.231 <0.058 0.0611 <0.053 <0.056 <0.053 <0.060 -- MW-34 30-Mar-22 200.4 5.15 0,20 <0.18 <20 78B 280E <2.5 <2.5 5,900 11,000 21 0.110 1.1 35 0.54J <3.0 350 0* 0.25J <0.058 0.211 0.331 <0.056 <0.053 <0.060 MW-34d 6-Nov-19 466.9 6.08 0.61 2.8 <20 -- 3.OB1 <10 <10 -- 12,000 9.2 1.0 1.6 65 1.4 <1.0 150 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-34d 4-Feb-20 347.9 5.88 0.28 -- <20 130 26 <SO <10 550 12,000 -- 2.0 -- 52 3.2 -- 550 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-34d 8-Apr-20 129.4 5.85 1.40 2.61�s1 <20 120 3.OJ <10 <10 110 13,000 10 1.0 1.2 70 1.8 <1.0 87 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-34d 30-Jul-20 -13.3 5.83 0.93 <20 120 2.81 <10 <10 120 12,000 -- 1.7 -- -- 5.9 -- 100 0* <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 -- MW-34d 15-Oct-20 -22.1 5.82 1.39 3.6j1' <20 150 4.OJ <SO <10 86 14,000 11 1.3E <1.0 75 2.2 <1.0 88 0* 0.43J <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 -- MW-34d 31-Mar-21 223.4 5.46 0.35 <2.0 <20 130 6.7J <30 <30 160 8,600 9.9 0.50 <1.0 59 1.2 <1.0 110 0* 0.27J <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 -- MW-34d 10-Nov-21 428.9 6.09 0.83 <2.0 <20 150 <10 <30 <30 <50 13,000 16 2.0 <1.0 68 5.3 <1.0 96 0* 0.25J <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 -- MW-34d 29-Mar-22 220.2 5.73 1,48 <0.18 <20 25 5.9B1 <2.5 <2.5 17 3.8H <3.0 63 14 <3.0 27 0* <0.12 <0.058 <0.058 0.0541 <0.056 <0.053 <0.060 MW-36 25-Apr-12 122.2 5.71 2.84 5.2 29 -- 186D <0.2 <0.54 -- -- 5.9 0.5J 1.1 60 3.91 <0.01 336D <0.046 <0.04 <0.24 <0.87 0.0731 <O.048 <0.057 <0.061 -- MW-36 23-Oct-12 139.1 5.92 8.39 <2 <30 -- 39.6 <0.2 <0.54 -- -- 6B 0.4901 1.7 67 3.91 <0.01 196D <0.046 <0.031 <0.031 <0.078 <0.095 <0.052 <0.063 <0.01 -- MW-36 17-Apr-13 118.1 6.05 2.44 12 <16 -- 6.4 <0.061 <0.069 -- -- 5.59 0.59 1.1 66.3 2.19 <0.4 98 0.8* <0.5 <1 <0.5 <0.5 <0.25 -- MW-36 16-Oct-13 188.5 5.82 3.89 <4 38 -- 9.8 <0.061 <0.069 -- -- 5.50 0.73 1.1 59.2 2.19 <0.4 81B 1.5* <0.5 <1 <0.5 <0.5 <0.25 -- MW-36 16-Apr-14 165.3 5.76 3.08 (1) 71 -- 17 <0.061 <0.069 -- -- 5.8 0.86 0.61 55.6 2.3 <0.4 110 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-36 12-Nov-14 96.2 5.76 2.23 (1) 37 -- 25 <0.061 <0.069 -- -- 5.8 0.98 <0.09 55.3 2.68 <0.4 83 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-36 30-Apr-15 1.6 5.69 3.15 4.10 <16 -- 3.6 <0.061 <0.069 -- -- 5.8 0.89 1.4 58.4 2.3 <0.4 81 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-36 15-Oct-15 167.8 5.97 3.78 <2.0 33 -- 2.5 <0.061 <0.069 -- -- 5.5 0.704 1.2 59.3 3.0 0.4J 72 0* <0.50 <1.0 <0.50 <0.50 <0.020 -- MW-36 20-Apr-16 125.4 5.80 2.49 <2.0 <12 -- 2.5 <0.061 <0.069 -- -- 5.9 0.60 1.0 53.7 2.3 <0.4 76 2.0* <0.50 <1.0 <0.50 <0.50 <0.020 -- MW-36 13-5ep-16 176.6 5.13 2.15 <2.0 <10 -- - - - -- -- 6.7 0.81 <1.0 55 2.5 <1.0 - 0.5* - - - - - -- MW-36 20-Apr-17 143.0 5.79 1.77 <2.0 <10 -- 5.OJ <SO <10 -- -- 6.9 0.79 0.70J 51 1.3 <1.0 190.0 2.0* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 -- MW-36 22-Sep-17 143.0 6.00 1.95 <2.0 <10 -- 2.9 <SO <10 -- -- 7.3 0.66 0.78 63 2.4 <1.0 220.0 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-36 13-Apr-18 45.2 5.81 1.35 <2.0 <10 -- <10 <SO <SO -- -- 6.9 0.66 0.83J 58B 3.3 <1.0 71.0 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0. 10 <0.10 -- MW-36 25-Oct-18 98.4 5.53 0.86 <2.0 20 -- 3.9B1 <10 <10 -- -- 7.8 0.64 1.5 60 1.8 <1.0 190 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-36 25-Apr-19 123.4 5.77 0.94 <2.0 <20 -- <10 <SO <SO -- -- 8.9 0.62 1.0 61 2.3 <1.0 280 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-36 5-Nov-19 146.4 6.00 0.57 <2.0 <20 -- 4.5B1 <10 <10 -- -- 8.8 0.60 1.0 58 1.9 1.1 390 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-36 7-Apr-20 63.9 5.69 0.74 <2.0 <20 -- 5.6B1 <SO <SO -- -- 9.1 0.57 <1.0 59 2.0 <1.0 120 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-36 15-Oct-20 -33.1 5.67 0.67 <2.0 <20 -- 5.5J <10 <10 -- -- 9.6 0.40B <1.0 63 2.5 <1.0 150 0* 4.11 <0.58 <0.58 <0.53 <0.56 <0.53 <0.60 -- MW-36 31-Mar-21 125.9 5.22 1.93 <2.0 <20 -- 47 <SO <SO -- -- 9.3 0.16 <1.0 56 2.9 1.3 140 0* 1.21 <0.29 <0.29 <0.26 <0.28 <0.26 <0.30 -- MW-36 11-Nov-21 14.6 5.95 0.78 <2.0 <20 -- 37 <10 <10 -- -- 111 0.211 1.2 88 3.1 <1.0 210 0* 0.271 <0.058 0.0591 <0.053 <0.056 <0.053 <0.060 -- MW-36 30-Mar-22 112.71 5.68 0.08 <0.18 1 <20 1 1 14 1 <2.5 1 <2.5 1 1 1 11D I 0.42HD 1.4 86 <2.5 <3.0 280 0* <0.12 <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 Notes: 1. All units are in milligrams per liter ((mg/L) parts per million), unless otherwise noted. 2. µg/L- micrograms per liter (parts per billion) 3. CaCO3 - Calcium Carbonate 4. MW-11 is a background well for the North Wake Unlined Landfill. 5. * - Field analysis performed using a HACH kit. 6. (--) - Not Measured 7. J - Indicates the analytical result is an estimated concentration between the method detection limit and the limit of quantitation. 8. B -The analyte concentration detected in the method blank was greater than the method detection limit. 9. D, d - Analyzed as dilution. 10. UX - The compound was analyzed for, but not detected. 1 mL HNO3 was added to MW-6 for metals upon receipt to get the pH to less than 2. 11. (1) - BOD was measured following dilution and did not meet the oxygen depletion criterion of at least 2 mg/L. The elevated BOD concentrations are a result of laboratory error and were not used to evaluate natural attenuation for the April and November 2014 sampling events. 12. i.xl 1 flag - The average BOD for MW-9, -10, -36, and -11 is lower than the valid range. 13. (-) Samples not collected and analyzed for the spring 2016 sampling event. 14. H -The analyte was analyzed outside of holding time. 15l"I - 7 flag - The seed correction factor was above the method range. Results may be biased low. 16. l.sl- 75 flag - The sample became depleted. The reported result was computed using the greatest dilution and the least amount of sample. 17. l"l- M3 flag - The matrix spike duplicate sample recovery was outside laboratory control limits. 18. lssl - MS flag - The matrix spike sample recovery was outside laboratory control limits. 19. 47 flag- Indicates a blank depletion less than 0.20 mg/L and a seed correction factor out of range. 20. 1201- 4 flag - The method blank result was higher than the method required limit of 0.20 mg/L. 21. E -The quantitation of the compound exceeded the calibration range. �- Blank cells indicate no data collected smithPage 3 of 3 June 2022 N w E MW-28 MW-28d :- 219.22 219.83 s % MW-22 •�- -t'� 1219.17 a- / . , teal , n LEGEND Groundwater Monitoring Well ' Surface Water Sample Location .«� • Injection Well Location Air Sparging Well Area Potentiometric Contour 218 — Idashed where inferred) k� tw Contour Interval = 2 Feet y SW-8 MW , MW-9 'Fin 1-10. h , J212.44Y MW-36 210.65 MW-36d MW-29d- MW-10d f 1 ' �, i I / 210.68 _,23271 226.79 ���• ' , ' 1 l d H p N N _. I.MW-23 N/.:/ ,N 1 1 ' ' I' N1 Nw to '229.12 N MW-30 N O ".;230.81 i MW-2 t W 19 y^� Unlinqd Landfill MW-31d t I 228.66 228.85 �'iobarrller Inje'ction NWIW-1/ 226.85 � , MW-24 , Area < i NWIW-2 NWIW-3�.� ,. 221.04. ' TB- 1a �, ' i NWIW-4 taV 226.90 \ '� , ' NWIW-5 NWIW-d' TB -la deep NWIW-7 LS 225.66 ` �� � '` 'r,� N. NWIW-8 MW-32 226.94 , r SW-3 1 MW-7 / \ 221.72 214.89 MW-8d 210.79 213.62 tt ,I SW-7 MW-6d 205.86 NW-6 '07.30 MW-35 207.23 MW-34 208.87 MW-34d 208.66 MW-5R 209.68 Map Data Source: February 2021 Aerial Photograph, 4kake County, North Figure 2 MW-6 - Total Volatile Organic Compounds Concentration Trend North Wake Unlined Landfill- Permit Number 9209MSWLF-1984 300 Completion Perimeter Migration Control Air Sparging System of the System Operational (January Operational (August Landfill Cap 2002) 2012) (July 1997) 250 Addition of 1,4-Dioxane to the Sampling Program (July 2018) p 200 — Q. t ca 150 c O c�a u c v 100 50 • '/ 2L ., .:t Lr) Lf1 l0 t.0 n r� 00 00 Ql a) O O ri N N M M ZT Vl N lD lD 00 00 Ql O O ri ri N N M rr) � U-) l0 LO r, r, 00 00 Ql Ql O O -1 -1 N O� Q� p� O� Ol p� O O O O O O O O O O O p O O O O O O O O ri ri ri ri ri ri ri ri ri ri ,� N ry N �y N L L L L L i i L L L i L L L L L L L L L L L L L L L L L L Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q cn J) J) 2i J) J) �n J) �n 61 J) V) (n v�i J) 2 V) 61 V) V) Ln 2 V) V) J) 2 Ln 2i Un 2i cn 2 Ln 2 cn 2i cn Date Smith June 2022 20 18 16 i 12 Q y� : M v' 10 4 2 0 Figure 3 MW-6d - Total Volatile Organic Compounds Concentration Trend North Wake Unlined Landfill- Permit Number 9209MSWLF-1984 c-I ci N N M M zT M M lD lD I- r- M M M M O O N N M M 'ZI- Ill M l0 l0 n r, M M M M O O c-I ci N v 4J N v N N v 4J N v N N v 4J N v N N m 4J N Date RP� A � June 2022 •ee 800 700 p 600 W ,. 500 t: M Q- c 400 c�a c a� u v 300 200 100 Figure 4 MW-9 - Total Volatile Organic Compounds Concentration Trend North Wake Unlined Landfill- Permit Number 9209MSWLF-1984 Completion of the Perimeter Migration Control System Landfill Cap (July Operational (January 2002) 1997) Air Spargi ng System Operational (August 2012) Addition of 1,4-Dioxane to the Sampling Program (July 2018) 0 ,t t Ln Ln 1.0 �.D n r- 00 00 0) M O O r-I c-I N N M CO U) N lD LD r, r- 00 00 Q1 Q1 O O r-I -j N N M M U) N to LO r- r, 00 00 a) 0) O O r-I N 0) a) T a) T T T T T T T T O O O O O O O O O O O O O O O O O O O O L L L L L L L L L L L L L L L L L L L L L L L Q Q Q Q Q Q Q Q 0- Q Q Q Q Q Q Q Q Q Q Q Q 0- Q Q 6- Q 6-Q L Date Smith June 2022 50 45 40 35 c 0 a� 30 0- t M 25 15 10 5 W7 Figure 5 MW-36 - Total Volatile Organic Compounds Concentration Trend North Wake Unlined Landfill- Permit Number 9209MSWLF-1984 Air Sparging System Operational (August 2012) Addition of 1,4-Dioxane to the Sampling Program (July 2018) 00 M m m m O O O O ,-' -- -- —i N N N N M M M M���t V1 Ln Ln In lD to lD lfl I- r- r- r- w w w w m m m m O O O O -1-- -1 c-I N O O O 99 r-I r-I r-I -I ri r-I r-I ri ri r-I ri r1 ri r-I r-I r-I r-i -1 -1 ci ri ri ri -1 ri ri r-I -I rl ri ri ri ri ri ri ri ri ri ri -1 N N N N N N N N N u i i Q u L C Q u L C Q u i C L u i C Q u i C Q u i C Q u L C Q u L C Q u i C Q u L C Q u i C Q u i C Q u i Ln n n v�i cn cn v�i v�i v�i Ln v�i in cn Date Smith June 2022 35 30 25 c 0 L Q 20 y� : M Q. 10 5 0 Figure 6 MW-36d - Total Volatile Organic Compounds Concentration Trend North Wake Unlined Landfill- Permit Number 9209MSWLF-1984 w M m m m coo O c-I c-I ri N N N N m m m m zt w W w w M m m m O O O O c-I ci ci N O O O O O IV -- -- rl -1 -- c-I c-I c-I c-I c-I -- N N N N N N N N N U i C Q U i C a U i C Q U i C Q U i C Q U C Q U L C Q U L C au i C Q U i C Q U i C Q U � C Q U i C Q U i L/) n 0 V) 0 � � V) 0 V) o � � vn o 2M � cn o 2i - cn o � � V) 0 -� ) 0� V) o 2 � Vn o 2 Date II nC Le 616 iA L June 2022 Figure 7 MW-5R - Volatile Organic Compounds Concentration Trends North Wake Unlined Landfill- Permit Number 9209MSWLF-1984 70 Total Volatile Organic Addition of 1,4-Dioxane Sodium Lactate EVO Injection Compounds to the Sampling Program Injection (December 2019) tTetrachloroethene (July 2018) (October 2019) 60 ❑ Trichloroethene f 1,1-Dichloroethane 50 0 cis-1,2-Dichloroethene ` o Methylene Chloride 0.40 t M a c 0 coo 30 L U C V 20 10 0 -0 [1 -1-0 0--b--0-0 [1 13 11 1111 11 13 O O i-- —i —i —i N N N N m m m m zt t �t Ln Ln Ln Ln 1-0 lD l0 lD 1, r- r- r W w w w M Ql M M O O O O —1 r-1 c-1 c-1 N r-1 r-1 r1 ri ri -1 ri ri ri r1 ri ri i--1 r-1 ri r-1 ri rl ri ri rl ri r-1 r1 ri ri ri ri ri -1 ri ri ri ri ri ri ri ri N N N N N N N N N Q U i C Q U i C Q U i C Q U i C Q U i C Q U i C Q U i C Q U i C Q U i C Q U i C Q U i C Q U i Ln M cn 0 cn 0 cn 0 cn 0 cn 0 Vn in Ln M Ln a �n 0 <n 0 (n 0 ".:! Date Smith June 2022 50 0 40 ai t M 30 c 0 M c v U u 20 10 a Figure 8 MW-34 - Volatile Organic Compounds Concentration Trends North Wake Unlined Landfill- Permit Number 9209MSWLF-1984 —Total Volatile Organic Compounds Addition of 1,4-Dioxane Sodium EVO Injection to the Sampling Program : Lactate (December 2019) ——Tetrachloroethene (July 2018) Injection Trichloroethene (October —1,1-Dichloroethane 2019) — —cis-1,2-Dichloroethene --v Methylene Chloride / r1 1 r1 N N N N M M M M - Vl ill Ln Ln l0 l0 to 1,0 1' r- r- r, W W W W M m m m O O O O r1 r1 r1 c-1 N rl rl 1 r1 r1 r1 r1 r1 r1 -1 rl r1 rl rl rl -1 r1 r1 rl r1 r1 r1 r1 r1 r1 r1 -1 r1 rl rl r1 r1 r1 -1 rl r1 N N N N N N N N N L i Q V i C Q U L C Q U i C Q U i C Q U i C L U i C Q U L C Q U L C Q U i C Q U i C Q U L V)i o �n o V) o cn o V) o U)i cu o V)i o cn o cn o V) o cn o Date CDM Smith June 2022 45 40 35 p 30 L 25 t M c 20 M L U C u 15 10 5 0 Figure 9 MW-34d - Volatile Organic Compounds Concentration Trends North Wake Unlined Landfill- Permit Number 9209MSWLF-1984 c-I -i -i N N N N M M M M V1 V1 V1 Ln l0 l0 l0 l0 I, n n r, W w w w M M M M O O O O -1 -1 rl N -1 -1 ri ri ri -1 ri ri rl -1 rl ri ri ri ri ri ri ri -1 rl ci ri ri ri ri -1 rl ci ri ri ri ri ri rl N N N N N N N N N L C Q U i C Q u L C Q U i C Q U i C Q U L C Q U i C Q U L C Q U i C Q U i C Q U L C Q U i V)i o �n o V) o cn o �n o V) o V) o cn o cn o cn o <n o Date CSpmith June 2022 Appendix A Analytical Data aceAnalytical Report of Analysis CDM Smith 5400 Glenwood Avenue Suite 400 Raleigh, NC 27612 Attention: Mathew Colone Project Name: North Wake Unlined Landfill Lot Number:XC30013 Date Completed:04/27/2022 05/04/2022 11:50 AM Approved and released by: Project Manager II: Cathy S. Dover =w�q a[cArFo f� /747iR TN I AM Nauvue Acm^r mn BuaN 11 � eOfFAi� A C C R E D I T E D TESTINGL aORlTOAY The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 1 of 279 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative CDM Smith Lot Number: XC30013 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Where sampling is conducted by the client, results relate to the accuracy of the information provided, and as the samples are received. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved The NELAC Institute (TNI) standards, the Pace Analytical Services, LLC ("Pace") Laboratory Quality Manual, standard operating procedures (SOPS), and Pace policies. Any exceptions to the TNI standards, the Laboratory Quality Manual, SOPS or policies are qualified on the results page or discussed below. Pace is a TNI accredited laboratory; however, the following analyses are currently not listed on our TNI scope of accreditation: Drinking Water: VOC (excluding BTEX, MTBE, Naphthalene, & 1,2-dichloroethane) EPA 524.2, E. coli and Total coliforms SM 9223 B-2004, Solid Chemical Material: TOC Walkley-Black, Biological Tissue: All, Non -Potable Water: SGT-HEM EPA 1664B, Silica EPA 200.7, Boron, Calcium, Silicon, Strontium EPA 200.8, Bicarbonate, Carbonate, and Hydroxide Alkalinity SM 2320 B-2011, SM 9221 C E-2006 & SM 9222D-2006, Strontium SW-846 6010D, VOC SM 6200 B-2011, Fecal Coliform Colilert-18. VOA 8260D The laboratory control sample (LCS) for analytical batch 37159 exceeded acceptance criteria for the following analytes: Acetone (207%), 2-Butanone (152%), 2-Hexanone (134%) and Acrylonitrile (146%). These analytes were biased high and were not detected in the associated samples: XC30013-019 (TRIP BLANK), XC30013- 021 (MW-5R), XC30013-022 (MW-34), XC30013-024 (MW-9), XC30013-025 (MW-36), XC30013-027 (MW- 10), XC30013-028 (MW-11), XC30013-029 (MW-11d), XC30013-030 (MW-22), XC30013-031 (MW-23), XC30013-032 (MW-24), XC30013-033 (MW-7), XC30013-034 (SW-7), XC30013-035 (SW-8), and XC30013- 036 (SW-3). The laboratory control sample (LCS) for analytical batch 37283 was biased high outside of acceptance criteria for MEK (2-Butanone). The following samples are associated with this LCS/batch were non -detect for MEk (2- Butanone): XC30013-037 (SW-2), XC30013-038 (TRIP BLANK(2)), and XC30013-041 (EQ BLANK). Dissolved Gases RSK175 The method blank associated with batch 37390 had Methane detected at a concentration that was above the DL but below the LOQ. All samples associated with this method blank that have detections for Methane have been flagged with a "B". ICP-MS Metals 6020B The following samples were murky/cloudy in appearance and analyzed on the instrument @ 5x dilution to protect the integrity of the instrument: XC30013-022 (MW-34), XC30013-025 (MW-36), and XC30013-031 (MW-23). The LOQ has been elevated to reflect the dilution. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 2 of 279 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Nitrate 300.0 The following samples were analyzed on the second day from collection, but not within the 48 hour holding time: XC30013-001 (MW-8), XC30013-003 (MW-34d), and XC30013-005 (MW-6). Also, samples XC30013- 001 (MW-8) and XC30013-005 (MW-6) were reanalyzed for a second analysis to confirm matrix associated with Run 1. The original analysis of sample XC30013-025 (MW-36) was performed outside of analytical hold time due to scheduling error. Samples XC30013-021 (MW-5R)and XC30013-024 (MW-9) were originally analyzed within holding time, the reanalysis was run outside holding time. Both runs have been reported. Sulfate 300.0 Sample XC30013-021 (MW-5R) was diluted due to the nature of the sample matrix. The LOQ has been elevated to reflect the dilution. Sample XC30013-025 (MW-36) was diluted due to the abundance of non -target analyte carbonate which interferes with nitrate. Elevated LOQs have been reported due to the dilution. Sulfide Samples XC30013-022 (MW-34) and XC30013-025 (MW-36) left behind a dark precipitate after filtration that caused mild color interference and made the endpoint difficult to determine with full accuracy. Both samples were non -detect and results were not affected. Sample XC30013-028 (MW-11) left behind a dark precipitate after filtration that caused some color interference during titration and made the endpoint difficult to determine. The endpoint appeared to have been overshot slightly. The MS/MSD for batch 37311 and parent sample XC30013-027 (MW-10), recovered outside the lower control limit. The associated LCS passed acceptance criteria. TDS The method blank associated with analytical batch 37025 contained TDS analysis greater than method criteria. The following samples were affected: XC30013-021 (MW-5R) and XC30013-022 (MW-34). The data has been reported. COD The MS for batch 37059 and parent sample XC30013-005 (MW-6), recovered outside the upper control limit. The associated LCS and MSD passed acceptance criteria. If you have any questions regarding this report, please contact the Pace Project Manager listed on the cover page. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 3 of 279 PACE ANALYTICAL SERVICES, LLC Sample Summary CDM Smith Lot Number: XC30013 Project Name: North Wake Unlined Landfill Project Number: Sample Number Sample ID Matrix Date Sampled Date Received 001 MW-8 Aqueous 03/29/2022 0845 03/30/2022 002 MW-8d Aqueous 03/29/2022 0910 03/30/2022 003 MW-34d Aqueous 03/29/20221005 03/30/2022 004 MW-6d Aqueous 03/29/20221110 03/30/2022 005 MW-6 Aqueous 03/29/20221130 03/30/2022 006 MW-36d Aqueous 03/29/20221230 03/30/2022 007 MW-10d Aqueous 03/29/20221345 03/30/2022 008 MW-23d Aqueous 03/29/20221420 03/30/2022 009 MW-32 Aqueous 03/29/20221455 03/30/2022 010 TB-1ad Aqueous 03/29/20221515 03/30/2022 011 MW-31 Aqueous 03/29/20221530 03/30/2022 012 MW-31d Aqueous 03/29/20221535 03/30/2022 013 MW-29d Aqueous 03/29/20221600 03/30/2022 014 MW-35 Aqueous 03/29/20221630 03/30/2022 015 MW-33 Aqueous 03/29/20221640 03/30/2022 016 MW-28 Aqueous 03/29/20221705 03/30/2022 017 MW-28d Aqueous 03/29/20221720 03/30/2022 018 DUP Aqueous 03/29/2022 0800 03/30/2022 019 TRIP BLANK Aqueous 03/29/2022 03/30/2022 020 MW-8 Aqueous 03/30/2022 0830 03/31/2022 021 MW-5R Aqueous 03/30/2022 0905 03/31/2022 022 MW-34 Aqueous 03/30/2022 0940 03/31/2022 023 MW-34d Aqueous 03/30/20221000 03/31/2022 024 MW-9 Aqueous 03/30/20221030 03/31/2022 025 MW-36 Aqueous 03/30/20221100 03/31/2022 026 MW-6 Aqueous 03/30/20221140 03/31/2022 027 MW-10 Aqueous 03/30/20221215 03/31/2022 028 MW-11 Aqueous 03/30/20221510 03/31/2022 029 MW-11d Aqueous 03/30/20221435 03/31/2022 030 MW-22 Aqueous 03/30/20221240 03/31/2022 031 MW-23 Aqueous 03/30/20221255 03/31/2022 032 MW-24 Aqueous 03/30/20221310 03/31/2022 033 MW-7 Aqueous 03/30/20221345 03/31/2022 034 SW-7 Aqueous 03/30/20221705 03/31/2022 035 SW-8 Aqueous 03/30/20221715 03/31/2022 036 SW-3 Aqueous 03/30/20221735 03/31/2022 037 SW-2 Aqueous 03/30/20221750 03/31/2022 038 TRIP BLANK(2) Aqueous 03/30/2022 03/31/2022 039 MW-29d(2) Aqueous 03/30/20221640 03/31/2022 040 MW-11(2) Aqueous 03/31/2022 04/01/2022 041 EQ BLANK Aqueous 03/31/2022 1000 04/01/2022 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 4 of 279 Sample Summary (Continued) Lot Number: XC30013 Sample Number Sample ID Matrix Date Sampled Date Received (41 samples) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 5 of 279 Inorganic non-metals Client:CDM Smith Laboratory ID:XC30013-001 Description: MW-8 Matrix: Aqueous Date Sampled:03/29/2022 0845 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/01/2022 0126 TAD 36971 1 (BOD, 5 day) SM 521OB-2011 1 04/04/2022 1643 CLL 03/30/2022 2018 36611 1 (Chloride) 300.0 1 03/31/2022 1738 CAW 36863 1 (CO2 (calcula) SM 4500-CO2 D 1 04/01/2022 0126 TAD 1 (COD) SM 5220D-2011 1 04/04/2022 1304 KKP 36767 1 (Nitrate - N) 300.0 1 03/31/2022 1738 SLP 36870 2 (Nitrate - N) 300.0 50 04/02/2022 1308 CAW 37024 1 (Sulfate) 300.0 1 03/31/2022 1738 CAW 36864 1 (Sulfide) SM 4500-S2 F-2011 1 04/05/2022 1745 SJL 37089 1 (TOC) SM 531 OC-2011 1 04/12/2022 0436 DMA 37761 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su BOD, 5 day Chloride CO2 (calculation) COD Sulfate Nitrate - N Sulfide Nitrate - N TOC SM 2320B-2011 180 20 20 mg CaCO3/L 1 SM 521OB-2011 2.0 U 2.0 0.18 mg/L 1 300.0 76 1.0 0.25 mg/L 1 124-38-9 SM 4500-CO2 D 340 27 27 mg/L 1 SM 5220D-2011 20 U 20 20 mg/L 1 300.0 1.5 1.0 0.25 mg/L 1 300.0 0.020 UH 0.020 0.0050 mg/L 1 18496-25-8 SM 4500-S2 F-2 1.0 US 1.0 1.0 mg/L 1 300.0 0.35 HJD 1.0 0.25 mg/L 2 SM 531OC-2011 4.5 1.0 1.0 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 6 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-001 Description: MW-8 Matrix: Aqueous Date Sampled:03/29/2022 0845 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/04/2022 2245 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.67 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.55 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 2.4 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 25 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 7 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-001 Description: MW-8 Matrix: Aqueous Date Sampled:03/29/2022 0845 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/04/2022 2245 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.45 J 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 104 70-130 111 70-130 104 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 8 of 279 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XC30013-001 Description: MW-8 Matrix: Aqueous Date Sampled:03/29/2022 0845 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/02/2022 0356 SDC 36925 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 8.1 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 105 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 9 of 279 Dissolved Gases Client:CDM Smith Laboratory ID:XC30013-001 Description: MW-8 Matrix: Aqueous Date Sampled:03/29/2022 0845 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/07/2022 1422 JM1 37390 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 150 B 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 10 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-001 Description: MW-8 Matrix: Aqueous Date Sampled:03/29/2022 0845 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0808 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 11 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-001 Description: MW-8 Matrix: Aqueous Date Sampled:03/29/2022 0845 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1323 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 96 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 8.8 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 11 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.4 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.6 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 12 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-002 Description: MW-8d Matrix: Aqueous Date Sampled:03/29/2022 0910 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/04/2022 2309 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 13 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-002 Description: MW-8d Matrix: Aqueous Date Sampled:03/29/2022 0910 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/04/2022 2309 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 96 70-130 104 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 14 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-002 Description: MW-8d Matrix: Aqueous Date Sampled:03/29/2022 0910 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0811 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 15 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-002 Description: MW-8d Matrix: Aqueous Date Sampled:03/29/2022 0910 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1349 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 17 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.6 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 4.3 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 16 of 279 Inorganic non-metals Client:CDM Smith Laboratory ID:XC30013-003 Description: MW-34d Matrix: Aqueous Date Sampled:03/29/2022 1005 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/01/2022 0132 TAD 36971 1 (BOD, 5 day) SM 521OB-2011 1 04/04/2022 1644 CLL 03/30/2022 2020 36611 1 (Chloride) 300.0 1 03/31/2022 1757 CAW 36863 1 (CO2 (calcula) SM 4500-CO2 D 1 04/01/2022 0132 TAD 1 (COD) SM 5220D-2011 1 04/04/2022 1259 KKP 36767 1 (Nitrate - N) 300.0 1 03/31/2022 1757 SLP 36870 1 (Sulfate) 300.0 1 03/31/2022 1757 CAW 36864 1 (Sulfide) SM 4500-S2 F-2011 1 04/05/2022 1745 SJL 37089 1 (TDS) SM 2540C-2011 1 04/01/2022 1837 CVR 36899 1 (TOC) SM 531 OC-2011 1 04/12/2022 0449 DMA 37761 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 63 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.0 U 2.0 0.18 mg/L 1 Chloride 300.0 17 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 200 27 27 mg/L 1 COD SM 5220D-2011 20 U 20 20 mg/L 1 Nitrate - N 300.0 3.8 H 0.020 0.0050 mg/L 1 Sulfate 300.0 14 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 1.0 mg/L 1 TDS SM 2540C-2011 160 25 25 mg/L 1 TOC SM 531OC-2011 1.0 U 1.0 1.0 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 17 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-003 Description: MW-34d Matrix: Aqueous Date Sampled:03/29/2022 1005 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/04/2022 2334 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 1.3 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 2.5 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.45 J 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 18 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-003 Description: MW-34d Matrix: Aqueous Date Sampled:03/29/2022 1005 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/04/2022 2334 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 100 70-130 107 70-130 102 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 19 of 279 Dissolved Gases Client:CDM Smith Laboratory ID:XC30013-003 Description: MW-34d Matrix: Aqueous Date Sampled:03/29/2022 1005 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/07/2022 1438 JM1 37390 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 5.9 BJ 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 20 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-003 Description: MW-34d Matrix: Aqueous Date Sampled:03/29/2022 1005 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0819 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 21 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-003 Description: MW-34d Matrix: Aqueous Date Sampled:03/29/2022 1005 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1353 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 27 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.16 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 9.7 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 22 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-004 Description: MW-6d Matrix: Aqueous Date Sampled:03/29/2022 1110 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/04/2022 2359 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.97 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.90 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 2.3 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 0.91 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.63 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.42 J 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.43 J 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 23 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-004 Description: MW-6d Matrix: Aqueous Date Sampled:03/29/2022 1110 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/04/2022 2359 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 95 70-130 104 70-130 95 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 24 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-004 Description: MW-6d Matrix: Aqueous Date Sampled:03/29/2022 1110 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0821 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 25 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-004 Description: MW-6d Matrix: Aqueous Date Sampled:03/29/2022 1110 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1356 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 27 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.7 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.3 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.7 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 2.8 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 26 of 279 Inorganic non-metals Client:CDM Smith Laboratory ID:XC30013-005 Description: MW-6 Matrix: Aqueous Date Sampled:03/29/2022 1130 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/01/2022 0139 TAD 36971 1 (BOD, 5 day) SM 521OB-2011 1 04/04/2022 1646 CLL 03/30/2022 2025 36611 1 (Chloride) 300.0 1 03/31/2022 1815 CAW 36863 1 (CO2 (calcula) SM 4500-CO2 D 1 04/01/2022 0139 TAD 2 (COD) SM 5220D-2011 1 04/05/2022 2012 KKP 37059 1 (Nitrate - N) 300.0 1 03/31/2022 1815 SLP 36870 2 (Nitrate - N) 300.0 50 04/02/2022 1230 CAW 37024 1 (Sulfate) 300.0 1 03/31/2022 1815 CAW 36864 1 (Sulfide) SM 4500-S2 F-2011 1 04/05/2022 1745 SJL 37089 1 (TOC) SM 531 OC-2011 1 04/12/2022 0502 DMA 37761 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 410 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.0 U 2.0 0.18 mg/L 1 Chloride 300.0 120 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 520 27 27 mg/L 1 COD SM 5220D-2011 24 S 20 20 mg/L 2 Sulfate 300.0 6.8 1.0 0.25 mg/L 1 Nitrate - N 300.0 7.1 H 0.020 0.0050 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 1.0 mg/L 1 Nitrate - N 300.0 8.1 HD 1.0 0.25 mg/L 2 TOC SM 531OC-2011 7.4 1.0 1.0 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 27 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-005 Description: MW-6 Matrix: Aqueous Date Sampled:03/29/2022 1130 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0024 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 1.2 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.80 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 28 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-005 Description: MW-6 Matrix: Aqueous Date Sampled:03/29/2022 1130 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0024 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 106 70-130 100 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 29 of 279 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XC30013-005 Description: MW-6 Matrix: Aqueous Date Sampled:03/29/2022 1130 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/07/2022 0108 JMM2 37351 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 17 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 106 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 30 of 279 Dissolved Gases Client:CDM Smith Laboratory ID:XC30013-005 Description: MW-6 Matrix: Aqueous Date Sampled:03/29/2022 1130 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/07/2022 1454 JM1 37390 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 3.1 BJ 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 31 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-005 Description: MW-6 Matrix: Aqueous Date Sampled:03/29/2022 1130 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0824 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00014 J 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 32 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-005 Description: MW-6 Matrix: Aqueous Date Sampled:03/29/2022 1130 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1400 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 220 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.17 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 11 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.7 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 7.0 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.7 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 33 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-006 Description: MW-36d Matrix: Aqueous Date Sampled:03/29/2022 1230 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0049 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 2.7 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 4.7 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 34 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-006 Description: MW-36d Matrix: Aqueous Date Sampled:03/29/2022 1230 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0049 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 105 70-130 113 70-130 105 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 35 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-006 Description: MW-36d Matrix: Aqueous Date Sampled:03/29/2022 1230 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0827 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 36 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-006 Description: MW-36d Matrix: Aqueous Date Sampled:03/29/2022 1230 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1404 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 50 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.8 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 7.2 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 2.3 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 4.0 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 15 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 37 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-007 Description: MW-10d Matrix: Aqueous Date Sampled:03/29/2022 1345 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0113 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.74 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 38 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-007 Description: MW-10d Matrix: Aqueous Date Sampled:03/29/2022 1345 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0113 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 92 70-130 100 70-130 96 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 39 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-007 Description: MW-10d Matrix: Aqueous Date Sampled:03/29/2022 1345 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0829 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 40 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-007 Description: MW-10d Matrix: Aqueous Date Sampled:03/29/2022 1345 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1408 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.59 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 5.5 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.70 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.0 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 12 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.81 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.5 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 41 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-008 Description: MW-23d Matrix: Aqueous Date Sampled:03/29/2022 1420 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0138 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 42 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-008 Description: MW-23d Matrix: Aqueous Date Sampled:03/29/2022 1420 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0138 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 99 70-130 107 70-130 100 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 43 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-008 Description: MW-23d Matrix: Aqueous Date Sampled:03/29/2022 1420 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0832 JAB2 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 44 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-008 Description: MW-23d Matrix: Aqueous Date Sampled:03/29/2022 1420 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1411 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 35 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.0 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.6 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.3 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.8 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 45 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-009 Description: MW-32 Matrix: Aqueous Date Sampled:03/29/2022 1455 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0203 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 2.1 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 46 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-009 Description: MW-32 Matrix: Aqueous Date Sampled:03/29/2022 1455 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0203 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 98 70-130 108 70-130 100 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 47 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-009 Description: MW-32 Matrix: Aqueous Date Sampled:03/29/2022 1455 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0840 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 48 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-009 Description: MW-32 Matrix: Aqueous Date Sampled:03/29/2022 1455 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1423 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 9.1 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.46 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.4 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 2.1 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 3.2 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.4 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.4 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 2.8 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 49 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-010 Description: TB-1ad Matrix: Aqueous Date Sampled:03/29/2022 1515 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/04/2022 2220 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.47 J 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 50 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-010 Description: TB-1ad Matrix: Aqueous Date Sampled:03/29/2022 1515 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/04/2022 2220 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 107 70-130 101 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 51 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-010 Description: TB-1ad Matrix: Aqueous Date Sampled:03/29/2022 1515 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0843 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 52 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-010 Description: TB-1ad Matrix: Aqueous Date Sampled:03/29/2022 1515 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1426 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 31 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.46 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.3 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 3.2 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.68 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 2.4 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 4.3 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 71 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 53 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-011 Description: MW-31 Matrix: Aqueous Date Sampled:03/29/2022 1530 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0228 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 54 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-011 Description: MW-31 Matrix: Aqueous Date Sampled:03/29/2022 1530 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0228 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 99 70-130 105 70-130 103 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 55 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-011 Description: MW-31 Matrix: Aqueous Date Sampled:03/29/2022 1530 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0846 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 56 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-011 Description: MW-31 Matrix: Aqueous Date Sampled:03/29/2022 1530 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1430 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 17 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.7 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.3 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.33 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.9 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.3 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.6 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 57 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-012 Description: MW-31d Matrix: Aqueous Date Sampled:03/29/2022 1535 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0252 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 3.1 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 58 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-012 Description: MW-31d Matrix: Aqueous Date Sampled:03/29/2022 1535 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0252 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 106 70-130 100 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 59 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-012 Description: MW-31d Matrix: Aqueous Date Sampled:03/29/2022 1535 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0848 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 60 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-012 Description: MW-31d Matrix: Aqueous Date Sampled:03/29/2022 1535 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1434 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.95 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 23 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.27 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.8 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 6.5 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.55 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 2.6 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.4 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 6.5 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 100 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 61 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-013 Description: MW-29d Matrix: Aqueous Date Sampled:03/29/2022 1600 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0317 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 62 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-013 Description: MW-29d Matrix: Aqueous Date Sampled:03/29/2022 1600 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0317 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 104 70-130 101 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 63 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-013 Description: MW-29d Matrix: Aqueous Date Sampled:03/29/2022 1600 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0851 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 64 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-013 Description: MW-29d Matrix: Aqueous Date Sampled:03/29/2022 1600 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1438 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.67 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 25 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 4.9 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 8.9 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.4 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 3.1 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 0.29 J 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 140 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 65 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-014 Description: MW-35 Matrix: Aqueous Date Sampled:03/29/2022 1630 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0342 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 1.1 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 2.1 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 1.2 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.55 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.85 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 66 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-014 Description: MW-35 Matrix: Aqueous Date Sampled:03/29/2022 1630 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0342 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 107 70-130 100 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 67 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-014 Description: MW-35 Matrix: Aqueous Date Sampled:03/29/2022 1630 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0854 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 68 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-014 Description: MW-35 Matrix: Aqueous Date Sampled:03/29/2022 1630 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1442 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 38 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.51 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.6 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 4.4 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.83 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.5 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.4 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 4.7 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 24 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 69 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-015 Description: MW-33 Matrix: Aqueous Date Sampled:03/29/2022 1640 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0406 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 70 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-015 Description: MW-33 Matrix: Aqueous Date Sampled:03/29/2022 1640 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0406 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 95 70-130 102 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 71 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-015 Description: MW-33 Matrix: Aqueous Date Sampled:03/29/2022 1640 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0856 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 72 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-015 Description: MW-33 Matrix: Aqueous Date Sampled:03/29/2022 1640 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1445 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 31 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.2 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 4.1 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 3.2 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 73 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-016 Description: MW-28 Matrix: Aqueous Date Sampled:03/29/2022 1705 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0431 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 74 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-016 Description: MW-28 Matrix: Aqueous Date Sampled:03/29/2022 1705 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0431 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 96 70-130 106 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 75 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-016 Description: MW-28 Matrix: Aqueous Date Sampled:03/29/2022 1705 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0859 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 76 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-016 Description: MW-28 Matrix: Aqueous Date Sampled:03/29/2022 1705 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1449 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 33 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.20 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 6.3 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 1.3 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.6 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.90 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 2.2 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.3 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 9.5 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 22 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 77 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-017 Description: MW-28d Matrix: Aqueous Date Sampled:03/29/2022 1720 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0456 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 78 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-017 Description: MW-28d Matrix: Aqueous Date Sampled:03/29/2022 1720 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0456 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 96 70-130 105 70-130 100 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 79 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-017 Description: MW-28d Matrix: Aqueous Date Sampled:03/29/2022 1720 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0902 JAB2 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 80 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-017 Description: MW-28d Matrix: Aqueous Date Sampled:03/29/2022 1720 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1453 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.55 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 13 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.6 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 7.0 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.4 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 2.4 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.3 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.2 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 31 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 81 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-018 Description: DUP Matrix: Aqueous Date Sampled:03/29/2022 0800 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0521 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 82 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-018 Description: DUP Matrix: Aqueous Date Sampled:03/29/2022 0800 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/2022 0521 JMM2 37071 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 104 70-130 101 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 83 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-018 Description: DUP Matrix: Aqueous Date Sampled:03/29/2022 0800 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0904 JA132 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 84 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-018 Description: DUP Matrix: Aqueous Date Sampled:03/29/2022 0800 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2022 1457 BNW Prep Date Batch 04/02/2022 0252 36687 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 36 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.2 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 4.1 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 85 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-019 Description: TRIP BLANK Matrix: Aqueous Date Sampled:03/29/2022 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221251 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 86 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-019 Description: TRIP BLANK Matrix: Aqueous Date Sampled:03/29/2022 Project Name: North Wake Unlined Landfill Date Received:03/30/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221251 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 92 70-130 118 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 87 of 279 Inorganic non-metals Client:CDM Smith Laboratory ID:XC30013-021 Description: MW-5R Matrix: Aqueous Date Sampled:03/30/2022 0905 Project Name: North Wake Unlined Landfill Date Received: 03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/01/2022 0145 TAD 36971 1 (BOD, 5 day) SM 521OB-2011 1 04/05/2022 1711 CLL 03/31/2022 1834 36744 1 (Chloride) 300.0 1 03/31/2022 1834 CAW 36863 1 (CO2 (calcula) SM 4500-CO2 D 1 04/01/2022 0145 TAD 1 (COD) SM 5220D-2011 1 04/05/2022 2013 KKP 37059 1 (Nitrate - N) 300.0 1 03/31/2022 1834 SLP 36870 2 (Nitrate - N) 300.0 50 04/02/2022 1211 CAW 37024 2 (Sulfate) 300.0 50 04/02/2022 1211 CAW 37014 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2022 1444 SJL 37311 1 (TDS) SM 2540C-2011 1 04/04/2022 1513 CVR 37025 1 (TOC) SM 531 OC-2011 1 04/12/2022 0515 DMA 37761 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 170 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 16 2.0 0.18 mg/L 1 Chloride 300.0 2.3 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 320 27 27 mg/L 1 COD SM 5220D-2011 59 20 20 mg/L 1 Sulfate 300.0 50 U 50 13 mg/L 2 Nitrate - N 300.0 0.020 0.020 0.0050 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 1.0 mg/L 1 Nitrate - N 300.0 0.36 HJD 1.0 0.25 mg/L 2 TDS SM 2540C-2011 170 B 25 25 mg/L 1 TOC SM 531OC-2011 12 1.0 1.0 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 88 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-021 Description: MW-5R Matrix: Aqueous Date Sampled:03/30/2022 0905 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221315 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 5.7 JL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.42 J 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 89 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-021 Description: MW-5R Matrix: Aqueous Date Sampled:03/30/2022 0905 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221315 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 92 70-130 113 70-130 97 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 90 of 279 Dissolved Gases Client:CDM Smith Laboratory ID:XC30013-021 Description: MW-5R Matrix: Aqueous Date Sampled:03/30/2022 0905 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/07/2022 1510 JM1 37390 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 3000 B 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 91 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-021 Description: MW-5R Matrix: Aqueous Date Sampled:03/30/2022 0905 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0912 JAB2 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 92 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-021 Description: MW-5R Matrix: Aqueous Date Sampled:03/30/2022 0905 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A 2 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1502 BNW 6020B 1 04/05/2022 1152 BNW Prep Date Batch 04/02/2022 0241 36830 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 40 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.15 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 39 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.9 J 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 41000 50 13 ug/L 1 Lead 7439-92-1 6020B 0.26 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 7.9 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Sodium 7440-23-5 6020B 3500 400 150 ug/L 2 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 4.3 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 93 of 279 Inorganic non-metals Client:CDM Smith Laboratory ID:XC30013-022 Description: MW-34 Matrix: Aqueous Date Sampled:03/30/2022 0940 Project Name: North Wake Unlined Landfill Date Received: 03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/01/2022 0158 TAD 36971 1 (BOD, 5 day) SM 521OB-2011 1 04/05/2022 1721 CLL 03/31/2022 1841 36744 1 (Chloride) 300.0 1 03/31/2022 1853 CAW 36863 1 (CO2 (calcula) SM 4500-CO2 D 1 04/01/2022 0158 TAD 1 (COD) SM 5220D-2011 1 04/05/2022 2013 KKP 37059 1 (Nitrate - N) 300.0 1 03/31/2022 1853 SLP 36870 1 (Sulfate) 300.0 1 03/31/2022 1853 CAW 36864 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2022 1444 SJL 37311 1 (TDS) SM 2540C-2011 1 04/04/2022 1513 CVR 37025 1 (TOC) SM 531 OC-2011 1 04/12/2022 0555 DMA 37761 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 35 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.0 U 2.0 0.18 mg/L 1 Chloride 300.0 21 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 350 27 27 mg/L 1 COD SM 5220D-2011 20 U 20 20 mg/L 1 Nitrate - N 300.0 0.11 0.020 0.0050 mg/L 1 Sulfate 300.0 0.54 J 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 1.0 mg/L 1 TDS SM 2540C-2011 78 B 25 25 mg/L 1 TOC SM 531OC-2011 1.1 1.0 1.0 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 94 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-022 Description: MW-34 Matrix: Aqueous Date Sampled:03/30/2022 0940 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221346 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.53 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.52 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 1.1 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 1.6 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 8.8 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 12 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 5.5 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 1.6 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 2.3 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.57 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 95 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-022 Description: MW-34 Matrix: Aqueous Date Sampled:03/30/2022 0940 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221346 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 84 70-130 116 70-130 95 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 96 of 279 Dissolved Gases Client:CDM Smith Laboratory ID:XC30013-022 Description: MW-34 Matrix: Aqueous Date Sampled:03/30/2022 0940 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/07/2022 1526 JM1 37390 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 280 B 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 97 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-022 Description: MW-34 Matrix: Aqueous Date Sampled:03/30/2022 0940 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0928 JAB2 04/01/2022 0324 36797 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00017 J 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 98 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-022 Description: MW-34 Matrix: Aqueous Date Sampled:03/30/2022 0940 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A 2 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1529 BNW 6020B 1 04/05/2022 1218 BNW Prep Date Batch 04/02/2022 0241 36830 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 10 U 10 2.5 ug/L 1 Arsenic 7440-38-2 6020B 10 U 10 6.3 ug/L 1 Barium 7440-39-3 6020B 150 25 6.3 ug/L 1 Beryllium 7440-41-7 6020B 1.1 J 2.0 0.75 ug/L 1 Cadmium 7440-43-9 6020B 2.5 U 2.5 0.63 ug/L 1 Chromium 7440-47-3 6020B 19 J 25 6.3 ug/L 1 Cobalt 7440-48-4 6020B 25 U 25 6.3 ug/L 1 Copper 7440-50-8 6020B 12 J 25 6.3 ug/L 1 Iron 7439-89-6 6020B 5900 250 63 ug/L 1 Lead 7439-92-1 6020B 1.9 J 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B 8.8 J 25 6.3 ug/L 1 Selenium 7782-49-2 6020B 25 U 25 6.3 ug/L 1 Silver 7440-22-4 6020B 5.0 U 5.0 1.3 ug/L 1 Sodium 7440-23-5 6020B 11000 2000 750 ug/L 2 Thallium 7440-28-0 6020B 2.5 U 2.5 0.75 ug/L 1 Vanadium 7440-62-2 6020B 17 J 25 13 ug/L 1 Zinc 7440-66-6 6020B 24 J 50 13 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 99 of 279 Inorganic non-metals Client:CDM Smith Laboratory ID:XC30013-024 Description: MW-9 Matrix: Aqueous Date Sampled:03/30/2022 1030 Project Name: North Wake Unlined Landfill Date Received: 03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/01/2022 0207 TAD 36971 1 (BOD, 5 day) SM 521OB-2011 1 04/05/2022 1722 CLL 03/31/2022 1844 36744 1 (Chloride) 300.0 1 03/31/2022 1912 CAW 36863 1 (CO2 (calcula) SM 4500-CO2 D 1 04/01/2022 0207 TAD 1 (COD) SM 5220D-2011 1 04/05/2022 2014 KKP 37059 1 (Nitrate - N) 300.0 1 03/31/2022 1912 SLP 36870 2 (Nitrate - N) 300.0 50 04/02/2022 1249 CAW 37024 1 (Sulfate) 300.0 1 03/31/2022 1912 CAW 36864 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2022 1444 SJL 37311 1 (TOC) SM 531 OC-2011 1 04/12/2022 0608 DMA 37761 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su BOD, 5 day Chloride CO2 (calculation) COD Sulfate Nitrate - N Sulfide Nitrate - N TOC SM 2320B-2011 550 20 20 mg CaCO3/L 1 SM 521OB-2011 2.4 2.0 0.18 mg/L 1 300.0 45 1.0 0.25 mg/L 1 124-38-9 SM 4500-CO2 D 720 27 27 mg/L 1 SM 5220D-2011 30 20 20 mg/L 1 300.0 5.0 1.0 0.25 mg/L 1 300.0 0.020 U 0.020 0.0050 mg/L 1 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 1.0 mg/L 1 300.0 0.37 HJD 1.0 0.25 mg/L 2 SM 531OC-2011 9.1 1.0 1.0 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 100 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-024 Description: MW-9 Matrix: Aqueous Date Sampled:03/30/2022 1030 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221411 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 1.0 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.45 J 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 15 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 5.4 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.42 J 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 6.0 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.42 J 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 101 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-024 Description: MW-9 Matrix: Aqueous Date Sampled:03/30/2022 1030 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221411 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 31 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 93 70-130 113 70-130 98 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 102 of 279 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XC30013-024 Description: MW-9 Matrix: Aqueous Date Sampled:03/30/2022 1030 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/09/2022 0104 SDC 37627 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 13 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 108 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 103 of 279 Dissolved Gases Client:CDM Smith Laboratory ID:XC30013-024 Description: MW-9 Matrix: Aqueous Date Sampled:03/30/2022 1030 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/07/2022 1542 JM1 37390 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 1600 B 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 104 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-024 Description: MW-9 Matrix: Aqueous Date Sampled:03/30/2022 1030 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0936 JA132 04/01/2022 0324 36798 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 105 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-024 Description: MW-9 Matrix: Aqueous Date Sampled:03/30/2022 1030 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1533 BNW Prep Date Batch 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 370 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.33 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 7.8 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.9 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 4.4 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 65 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 3.4 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 10 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 0.60 J 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.36 J 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 6.7 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 47 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 106 of 279 Inorganic non-metals Client:CDM Smith Laboratory ID:XC30013-025 Description: MW-36 Matrix: Aqueous Date Sampled:03/30/2022 1100 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/01/2022 0212 TAD 36971 1 (BOD, 5 day) SM 521OB-2011 1 04/05/2022 1724 CLL 03/31/2022 1846 36744 1 (Chloride) 300.0 10 04/04/2022 2017 CAW 37130 1 (CO2 (calcula) SM 4500-CO2 D 1 04/01/2022 0212 TAD 1 (COD) SM 5220D-2011 1 04/05/2022 2014 KKP 37059 1 (Nitrate - N) 300.0 10 04/04/2022 2017 CAW 37131 2 (Nitrate - N) 300.0 10 04/05/2022 1656 CAW 37267 1 (Sulfate) 300.0 10 04/04/2022 2017 CAW 37132 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2022 1444 SJL 37311 1 (TOC) SM 531 OC-2011 1 04/12/2022 0621 DMA 37761 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su BOD, 5 day Chloride CO2 (calculation) COD Sulfate Nitrate - N Sulfide Nitrate - N TOC SM 2320B-2011 86 20 20 mg CaCO3/L 1 SM 521OB-2011 2.0 U 2.0 0.18 mg/L 1 300.0 11 D 10 2.5 mg/L 1 124-38-9 SM 4500-CO2 D 280 27 27 mg/L 1 SM 5220D-2011 20 U 20 20 mg/L 1 300.0 10 U 10 2.5 mg/L 1 300.0 0.42 HD 0.20 0.050 mg/L 1 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 1.0 mg/L 1 300.0 0.43 HD 0.20 0.050 mg/L 2 SM 531OC-2011 1.4 1.0 1.0 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 107 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-025 Description: MW-36 Matrix: Aqueous Date Sampled:03/30/2022 1100 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221436 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 2.2 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 3.9 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 108 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-025 Description: MW-36 Matrix: Aqueous Date Sampled:03/30/2022 1100 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221436 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 1.2 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 88 70-130 113 70-130 97 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 109 of 279 Dissolved Gases Client:CDM Smith Laboratory ID:XC30013-025 Description: MW-36 Matrix: Aqueous Date Sampled:03/30/2022 1100 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/08/2022 1019 JM1 37532 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 14 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 110 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-025 Description: MW-36 Matrix: Aqueous Date Sampled:03/30/2022 1100 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0939 JA132 04/01/2022 0324 36798 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 111 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-025 Description: MW-36 Matrix: Aqueous Date Sampled:03/30/2022 1100 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1537 BNW Prep Date Batch 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 10 U 10 2.5 ug/L 1 Arsenic 7440-38-2 6020B 10 U 10 6.3 ug/L 1 Barium 7440-39-3 6020B 83 25 6.3 ug/L 1 Beryllium 7440-41-7 6020B 2.0 U 2.0 0.75 ug/L 1 Cadmium 7440-43-9 6020B 2.5 U 2.5 0.63 ug/L 1 Chromium 7440-47-3 6020B 17 J 25 6.3 ug/L 1 Cobalt 7440-48-4 6020B 25 U 25 6.3 ug/L 1 Copper 7440-50-8 6020B 19 J 25 6.3 ug/L 1 Lead 7439-92-1 6020B 5.0 U 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B 7.4 J 25 6.3 ug/L 1 Selenium 7782-49-2 6020B 25 U 25 6.3 ug/L 1 Silver 7440-22-4 6020B 5.0 U 5.0 1.3 ug/L 1 Thallium 7440-28-0 6020B 2.5 U 2.5 0.75 ug/L 1 Vanadium 7440-62-2 6020B 20 J 25 13 ug/L 1 Zinc 7440-66-6 6020B 21 J 50 13 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 112 of 279 Inorganic non-metals Client:CDM Smith Laboratory ID:XC30013-027 Description: MW-10 Matrix: Aqueous Date Sampled:03/30/2022 1215 Project Name: North Wake Unlined Landfill Date Received: 03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/01/2022 0218 TAD 36971 1 (BOD, 5 day) SM 521OB-2011 1 04/05/2022 1727 CLL 03/31/2022 1851 36744 1 (Chloride) 300.0 1 03/31/2022 1931 CAW 36863 1 (CO2 (calcula) SM 4500-CO2 D 1 04/01/2022 0218 TAD 1 (COD) SM 5220D-2011 1 04/05/2022 2014 KKP 37059 1 (Nitrate - N) 300.0 1 03/31/2022 1931 SLP 36870 1 (Sulfate) 300.0 1 03/31/2022 1931 CAW 36864 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2022 1444 SJL 37311 1 (TOC) SM 531 OC-2011 1 04/12/2022 0634 DMA 37761 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 75 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.0 U 2.0 0.18 mg/L 1 Chloride 300.0 2.8 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 190 27 27 mg/L 1 COD SM 5220D-2011 20 U 20 20 mg/L 1 Nitrate - N 300.0 0.61 0.020 0.0050 mg/L 1 Sulfate 300.0 0.59 J 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 US 1.0 1.0 mg/L 1 TOC SM 531OC-2011 1.0 U 1.0 1.0 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 113 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-027 Description: MW-10 Matrix: Aqueous Date Sampled:03/30/2022 1215 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221501 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.54 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.43 J 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 0.69 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.53 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 114 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-027 Description: MW-10 Matrix: Aqueous Date Sampled:03/30/2022 1215 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221501 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 86 70-130 114 70-130 95 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 115 of 279 Dissolved Gases Client:CDM Smith Laboratory ID:XC30013-027 Description: MW-10 Matrix: Aqueous Date Sampled:03/30/2022 1215 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/08/2022 1035 JM1 37532 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 330 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 116 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-027 Description: MW-10 Matrix: Aqueous Date Sampled:03/30/2022 1215 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0947 JA132 04/01/2022 0324 36798 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 117 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-027 Description: MW-10 Matrix: Aqueous Date Sampled:03/30/2022 1215 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1540 BNW Prep Date Batch 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 17 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.16 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.77 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.8 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 1.4 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 6.7 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.27 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 3.7 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 19 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 118 of 279 Inorganic non-metals Client:CDM Smith Laboratory ID:XC30013-028 Description: MW-11 Matrix: Aqueous Date Sampled:03/30/2022 1510 Project Name: North Wake Unlined Landfill Date Received: 03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/01/2022 0231 TAD 36972 1 (BOD, 5 day) SM 521OB-2011 1 04/05/2022 1728 CLL 03/31/2022 1854 36744 1 (Chloride) 300.0 1 03/31/2022 1950 CAW 36863 1 (CO2 (calcula) SM 4500-CO2 D 1 04/01/2022 0231 TAD 1 (COD) SM 5220D-2011 1 04/05/2022 2015 KKP 37059 1 (Nitrate - N) 300.0 1 03/31/2022 1950 SLP 36870 1 (Sulfate) 300.0 1 03/31/2022 1950 CAW 36864 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2022 1444 SJL 37311 1 (TOC) SM 531 OC-2011 1 04/12/2022 0714 DMA 37761 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 42 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.0 U 2.0 0.18 mg/L 1 Chloride 300.0 5.1 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CC2 D 180 27 27 mg/L 1 COD SM 5220D-2011 20 U 20 20 mg/L 1 Nitrate - N 300.0 0.88 0.020 0.0050 mg/L 1 Sulfate 300.0 1.0 U 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 1.0 mg/L 1 TOC SM 531OC-2011 1.0 U 1.0 1.0 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 119 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-028 Description: MW-11 Matrix: Aqueous Date Sampled:03/30/2022 1510 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221526 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 120 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-028 Description: MW-11 Matrix: Aqueous Date Sampled:03/30/2022 1510 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221526 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 93 70-130 114 70-130 98 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 121 of 279 Dissolved Gases Client:CDM Smith Laboratory ID:XC30013-028 Description: MW-11 Matrix: Aqueous Date Sampled:03/30/2022 1510 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/08/2022 1051 JM1 37532 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 122 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-029 Description: MW-11d Matrix: Aqueous Date Sampled:03/30/2022 1435 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221551 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 123 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-029 Description: MW-11d Matrix: Aqueous Date Sampled:03/30/2022 1435 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221551 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 86 70-130 118 70-130 97 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 124 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-029 Description: MW-11d Matrix: Aqueous Date Sampled:03/30/2022 1435 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0949 JA132 04/01/2022 0324 36798 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 125 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-029 Description: MW-11d Matrix: Aqueous Date Sampled:03/30/2022 1435 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1544 BNW Prep Date Batch 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 44 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.5 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.7 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 3.4 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 126 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-030 Description: MW-22 Matrix: Aqueous Date Sampled:03/30/2022 1240 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221616 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 127 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-030 Description: MW-22 Matrix: Aqueous Date Sampled:03/30/2022 1240 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221616 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 94 70-130 115 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 128 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-030 Description: MW-22 Matrix: Aqueous Date Sampled:03/30/2022 1240 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 0957 JA132 04/01/2022 0324 36798 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 129 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-030 Description: MW-22 Matrix: Aqueous Date Sampled:03/30/2022 1240 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1548 BNW Prep Date Batch 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 30 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.37 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 40 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 11 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 8.8 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 130 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-031 Description: MW-23 Matrix: Aqueous Date Sampled:03/30/2022 1255 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221641 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 131 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-031 Description: MW-23 Matrix: Aqueous Date Sampled:03/30/2022 1255 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221641 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 91 70-130 115 70-130 99 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 132 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-031 Description: MW-23 Matrix: Aqueous Date Sampled:03/30/2022 1255 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 1000 JA132 04/01/2022 0324 36798 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 133 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-031 Description: MW-23 Matrix: Aqueous Date Sampled:03/30/2022 1255 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1552 BNW Prep Date Batch 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 10 U 10 2.5 ug/L 1 Arsenic 7440-38-2 6020B 10 U 10 6.3 ug/L 1 Barium 7440-39-3 6020B 26 25 6.3 ug/L 1 Beryllium 7440-41-7 6020B 2.0 U 2.0 0.75 ug/L 1 Cadmium 7440-43-9 6020B 2.5 U 2.5 0.63 ug/L 1 Chromium 7440-47-3 6020B 25 U 25 6.3 ug/L 1 Cobalt 7440-48-4 6020B 25 U 25 6.3 ug/L 1 Copper 7440-50-8 6020B 25 U 25 6.3 ug/L 1 Lead 7439-92-1 6020B 2.5 J 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B 25 U 25 6.3 ug/L 1 Selenium 7782-49-2 6020B 25 U 25 6.3 ug/L 1 Silver 7440-22-4 6020B 5.0 U 5.0 1.3 ug/L 1 Thallium 7440-28-0 6020B 2.5 U 2.5 0.75 ug/L 1 Vanadium 7440-62-2 6020B 25 U 25 13 ug/L 1 Zinc 7440-66-6 6020B 14 J 50 13 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 134 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-032 Description: MW-24 Matrix: Aqueous Date Sampled:03/30/2022 1310 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221706 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.67 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 135 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-032 Description: MW-24 Matrix: Aqueous Date Sampled:03/30/2022 1310 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221706 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 88 70-130 119 70-130 97 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 136 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-032 Description: MW-24 Matrix: Aqueous Date Sampled:03/30/2022 1310 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 1003 JA132 04/01/2022 0324 36798 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 137 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-032 Description: MW-24 Matrix: Aqueous Date Sampled:03/30/2022 1310 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1556 BNW Prep Date Batch 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 19 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.9 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.61 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.8 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 2.6 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.6 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 138 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-033 Description: MW-7 Matrix: Aqueous Date Sampled:03/30/2022 1345 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221731 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.85 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 1.6 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.45 J 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 1.4 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 139 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-033 Description: MW-7 Matrix: Aqueous Date Sampled:03/30/2022 1345 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221731 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 92 70-130 116 70-130 98 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 140 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-033 Description: MW-7 Matrix: Aqueous Date Sampled:03/30/2022 1345 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 1006 JA132 04/01/2022 0324 36798 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 141 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-033 Description: MW-7 Matrix: Aqueous Date Sampled:03/30/2022 1345 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1600 BNW Prep Date Batch 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 32 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 34 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 3.2 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 10 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.4 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 142 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-034 Description: SW-7 Matrix: Aqueous Date Sampled:03/30/2022 1705 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221756 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 143 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-034 Description: SW-7 Matrix: Aqueous Date Sampled:03/30/2022 1705 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221756 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 90 70-130 116 70-130 96 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 144 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-034 Description: SW-7 Matrix: Aqueous Date Sampled:03/30/2022 1705 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 1008 JA132 04/01/2022 0324 36798 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 145 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-034 Description: SW-7 Matrix: Aqueous Date Sampled:03/30/2022 1705 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1612 BNW Prep Date Batch 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 21 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 146 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-035 Description: SW-8 Matrix: Aqueous Date Sampled:03/30/2022 1715 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221821 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 147 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-035 Description: SW-8 Matrix: Aqueous Date Sampled:03/30/2022 1715 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221821 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 88 70-130 115 70-130 96 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 148 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-035 Description: SW-8 Matrix: Aqueous Date Sampled:03/30/2022 1715 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 1011 JA132 04/01/2022 0324 36798 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 149 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-035 Description: SW-8 Matrix: Aqueous Date Sampled:03/30/2022 1715 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1615 BNW Prep Date Batch 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 20 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 150 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-036 Description: SW-3 Matrix: Aqueous Date Sampled:03/30/2022 1735 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221846 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 UL 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 UL 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 151 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-036 Description: SW-3 Matrix: Aqueous Date Sampled:03/30/2022 1735 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20221846 BWS 37159 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 89 70-130 114 70-130 97 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 152 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-036 Description: SW-3 Matrix: Aqueous Date Sampled:03/30/2022 1735 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 1014 JA132 04/01/2022 0324 36798 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 153 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-036 Description: SW-3 Matrix: Aqueous Date Sampled:03/30/2022 1735 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1619 BNW Prep Date Batch 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 27 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 154 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-037 Description: SW-2 Matrix: Aqueous Date Sampled:03/30/2022 1750 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20221258 BWS 37283 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 155 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-037 Description: SW-2 Matrix: Aqueous Date Sampled:03/30/2022 1750 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20221258 BWS 37283 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 94 70-130 107 70-130 101 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 156 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-037 Description: SW-2 Matrix: Aqueous Date Sampled:03/30/2022 1750 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/01/2022 1016 JA132 04/01/2022 0324 36798 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 157 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-037 Description: SW-2 Matrix: Aqueous Date Sampled:03/30/2022 1750 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/04/2022 1623 BNW Prep Date Batch 04/02/2022 0241 36830 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 34 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 158 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-038 Description: TRIP BLANK(2) Matrix: Aqueous Date Sampled:03/30/2022 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20221120 BWS 37283 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 159 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-038 Description: TRIP BLANK(2) Matrix: Aqueous Date Sampled:03/30/2022 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20221120 BWS 37283 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 110 70-130 103 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 160 of 279 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XC30013-038 Description: TRIP BLANK(2) Matrix: Aqueous Date Sampled:03/30/2022 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/06/2022 2130 JMM2 37351 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 3.0 U 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 105 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 161 of 279 Semivolatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-039 Description: MW-29d(2) Matrix: Aqueous Date Sampled:03/30/2022 1640 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3520C 8270E 1 04/07/2022 1628 JCG 04/05/2022 1500 37155 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run bis(2-Ethylhexyl)phthalate 117-81-7 8270E 2.6 J 4.0 0.50 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 2-Fluorobiphenyl 2-Fluorophenol Nitrobenzene-d5 Phenol-d5 Terphenyl-d14 2,4,6-Tribromophenol 81 37-129 48 24-127 86 38-127 59 28-128 96 10-148 87 35-144 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 162 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-040 Description: MW-11(2) Matrix: Aqueous Date Sampled:03/31/2022 Project Name: North Wake Unlined Landfill Date Received:04/01/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/06/2022 0521 JAB2 04/06/2022 0228 37214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 163 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-040 Description: MW-11(2) Matrix: Aqueous Date Sampled:03/31/2022 Project Name: North Wake Unlined Landfill Date Received:04/01/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/12/2022 1151 BPK Prep Date Batch 04/09/2022 0609 37255 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 53 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.7 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.6 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.45 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.6 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 7.9 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 164 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-041 Description: EQ BLANK Matrix: Aqueous Date Sampled:03/31/2022 1000 Project Name: North Wake Unlined Landfill Date Received:04/01/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20221145 BWS 37283 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 UL 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 165 of 279 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:XC30013-041 Description: EQ BLANK Matrix: Aqueous Date Sampled:03/31/2022 1000 Project Name: North Wake Unlined Landfill Date Received:04/01/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20221145 BWS 37283 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 89 70-130 102 70-130 97 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 166 of 279 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:XC30013-041 Description: EQ BLANK Matrix: Aqueous Date Sampled:03/31/2022 1000 Project Name: North Wake Unlined Landfill Date Received:04/01/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/09/2022 0129 SDC 37627 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 3.0 U 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 107 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 167 of 279 CVAA Client:CDM Smith Laboratory ID:XC30013-041 Description: EQ BLANK Matrix: Aqueous Date Sampled:03/31/2022 1000 Project Name: North Wake Unlined Landfill Date Received:04/01/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/06/2022 0523 JAB2 04/06/2022 0228 37214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 168 of 279 ICP-MS Metals Client:CDM Smith Laboratory ID:XC30013-041 Description: EQ BLANK Matrix: Aqueous Date Sampled:03/31/2022 1000 Project Name: North Wake Unlined Landfill Date Received:04/01/2022 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/12/2022 1154 BPK Prep Date Batch 04/09/2022 0609 37255 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 5.0 U 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 169 of 279 QC Summary Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XC30013 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 170 of 279 Inorganic non-metals - BOD Blank and GGA Matrix: Aqueous Batch: 36611 SCF: 0.8 Analytical Method: SM 521 OB-2011 SCF Range: 0.6 - 1.0 Result Avg. Result Sample ID Depl Avg. Depl (mg/L) (mg/L) Q Limit Prep Date Analysis Date XQ36611-041 (Blank) 0.16 0.2 03/30/2022 1912 04/04/2022 1554 XQ36611-141 (Blank) 0.16 0.2 03/30/2022 1912 04/04/2022 1554 XQ36611-241 (Blank) 0.13 0.15 0.2 03/30/2022 1912 04/04/2022 1554 XQ36611-035 (GGA) 160.5 1 167.5-228.5 03/30/2022 1918 04/04/2022 1558 XQ36611-135 (GGA) 173 167.5-228.5 03/30/2022 1918 04/04/2022 1557 XQ36611-235 (GGA) 174.5 169.3 167.5-228.5 03/30/2022 1918 04/04/2022 1557 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 171 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - BOD Blank and GGA Matrix: Aqueous Batch: 36744 SCF: 0.9 Analytical Method: SM 521 OB-2011 SCF Range: 0.6 - 1.0 Result Avg. Result Sample ID Depl Avg. Depl (mg/L) (mg/L) Q Limit Prep Date Analysis Date XQ36744-041 (Blank) 0.06 0.2 03/31/2022 1752 04/05/2022 1636 XQ36744-141 (Blank) 0.12 0.2 03/31/2022 1752 04/05/2022 1635 XQ36744-241 (Blank) 0.19 0.12 0.2 03/31/2022 1752 04/05/2022 1635 XQ36744-035 (GGA) 164.7 1 167.5-228.5 03/31/2022 1758 04/05/2022 1641 XQ36744-135 (GGA) 185.2 167.5-228.5 03/31/2022 1758 04/05/2022 1641 XQ36744-235 (GGA) 182.2 177.4 167.5-228.5 03/31/2022 1758 04/05/2022 1643 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 172 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ36767-001 Matrix: Aqueous Batch:36767 Analytical Method: SM 5220D-2011 Parameter Result Q Dil LOQ DL Units Analysis Date COD 20 U 1 20 20 mg/L 04/04/20221252 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 173 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ36767-002 Matrix: Aqueous Batch:36767 Analytical Method: SM 5220D-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date COD 40 42 1 105 95-105 04/04/20221252 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 174 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ36863-001 Matrix: Aqueous Batch:36863 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Chloride 1.0 U 1 1.0 0.25 mg/L 03/31/20221641 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 175 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ36863-002 Matrix: Aqueous Batch:36863 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Chloride 20 19 1 94 90-110 03/31/20221719 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 176 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MS Sample ID: XC30013-028MS Matrix: Aqueous Batch:36863 Analytical Method: 300.0 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Chloride 5.1 10 15 1 97 90-110 03/31/2022 2047 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 177 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MSD Sample ID: XC30013-028MD Matrix: Aqueous Batch:36863 Analytical Method: 300.0 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Chloride 5.1 10 15 1 96 0.84 90-110 20 03/31/2022 2106 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 178 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ36864-001 Matrix: Aqueous Batch:36864 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate 1.0 U 1 1.0 0.25 mg/L 03/31/20221641 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 179 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ36864-002 Matrix: Aqueous Batch:36864 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfate 20 19 1 94 90-110 03/31/20221719 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 180 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MS Sample ID: XC30013-028MS Matrix: Aqueous Batch:36864 Analytical Method: 300.0 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfate 0.0 10 10 1 104 90-110 03/31/2022 2047 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 181 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MSD Sample ID: XC30013-028MD Matrix: Aqueous Batch:36864 Analytical Method: 300.0 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Sulfate 0.0 10 11 1 106 2.1 90-110 20 03/31/2022 2106 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 182 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ36870-001 Matrix: Aqueous Batch:36870 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N 0.020 U 1 0.020 0.0050 mg/L 03/31/2022 1641 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 183 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ36870-002 Matrix: Aqueous Batch:36870 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Nitrate - N 0.80 0.77 1 96 90-110 03/31/2022 1719 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 184 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MS Sample ID: XC30013-028MS Matrix: Aqueous Batch:36870 Analytical Method: 300.0 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Nitrate - N 0.88 0.40 1.3 1 95 90-110 03/31/2022 2047 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 185 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MSD Sample ID: XC30013-028MD Matrix: Aqueous Batch:36870 Analytical Method: 300.0 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Nitrate - N 0.88 0.40 1.3 1 97 0.39 90-110 20 03/31/2022 2106 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 186 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ36899-001 Matrix: Aqueous Batch: 36899 Analytical Method: SM 2540C-2011 Parameter Result Q Dil LOQ DL Units Analysis Date TDS 25 U 1 25 25 mg/L 04/01/20221837 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 187 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ36899-002 Matrix: Aqueous Batch: 36899 Analytical Method: SM 2540C-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date TDS 50 53 1 106 90-110 04/01/20221837 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 188 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ36971-002 Matrix: Aqueous Batch: 36971 Analytical Method: SM 2320B-2011 Spike Amount Result %Rec Parameter (mg CaCO3/L) (mg CaCO3/L) Q Dil % Rec Limit Analysis Date Alkalinity @ pH 4.5 su 100 100 1 101 90-110 03/31/2022 2347 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 189 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ36972-002 Matrix: Aqueous Batch: 36972 Analytical Method: SM 2320B-2011 Spike Amount Result %Rec Parameter (mg CaCO3/L) (mg CaCO3/L) Q Dil % Rec Limit Analysis Date Alkalinity @ pH 4.5 su 100 100 1 103 90-110 04/01/2022 0226 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 190 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ37014-001 Matrix: Aqueous Batch: 37014 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate 1.0 U 1 1.0 0.25 mg/L 04/02/2022 0611 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 191 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ37014-002 Matrix: Aqueous Batch: 37014 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfate 20 19 1 94 90-110 04/02/2022 0727 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 192 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ37024-001 Matrix: Aqueous Batch:37024 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N 0.020 U 1 0.020 0.0050 mg/L 04/02/2022 0611 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 193 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ37024-002 Matrix: Aqueous Batch:37024 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Nitrate - N 0.80 0.76 1 95 90-110 04/02/2022 0727 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 194 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ37025-001 Matrix: Aqueous Batch: 37025 Analytical Method: SM 2540C-2011 Parameter Result Q Dil LOQ DL Units Analysis Date TDS 150 1 25 25 mg/L 04/04/20221513 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 195 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ37025-002 Matrix: Aqueous Batch: 37025 Analytical Method: SM 2540C-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date TDS 50 47 1 94 90-110 04/04/20221513 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 196 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ37059-001 Matrix: Aqueous Batch: 37059 Analytical Method: SM 5220D-2011 Parameter Result Q Dil LOQ DL Units Analysis Date COD 20 U 1 20 20 mg/L 04/05/2022 2012 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 197 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ37059-002 Matrix: Aqueous Batch: 37059 Analytical Method: SM 5220D-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date COD 40 41 1 102 95-105 04/05/2022 2012 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 198 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MS Sample ID: XC30013-005MS Matrix: Aqueous Batch: 37059 Analytical Method: SM 5220D-2011 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date COD 24 40 79 N 1 139 90-110 04/05/2022 2013 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 199 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MSD Sample ID: XC30013-005MD Matrix: Aqueous Batch: 37059 Analytical Method: SM 5220D-2011 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date COD 24 40 66 1 107 18 90-110 20 04/05/2022 2013 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 200 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MS Sample ID: XC30013-027MS Matrix: Aqueous Batch: 37059 Analytical Method: SM 5220D-2011 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date COD 0.0 40 43 1 107 90-110 04/05/2022 2014 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 201 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MSD Sample ID: XC30013-027MD Matrix: Aqueous Batch: 37059 Analytical Method: SM 5220D-2011 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date COD 0.0 40 41 1 103 3.3 90-110 20 04/05/2022 2015 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 202 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ37089-001 Matrix: Aqueous Batch: 37089 Analytical Method: SM 4500-S2 F-2011 Parameter Result Q Dil LOQ DL Units Analysis Date Sulfide 1.0 U 1 1.0 1.0 mg/L 04/05/20221745 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 203 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ37089-002 Matrix: Aqueous Batch: 37089 Analytical Method: SM 4500-S2 F-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfide 10 9.2 1 92 80-120 04/05/20221745 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 204 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MS Sample ID: XC30013-001 MS Matrix: Aqueous Batch: 37089 Analytical Method: SM 4500-S2 F-2011 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfide 0.0 10 6.2 N 1 62 70-130 04/05/20221745 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 205 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MSD Sample ID: XC30013-001 MD Matrix: Aqueous Batch: 37089 Analytical Method: SM 4500-S2 F-2011 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Sulfide 0.0 10 5.8 N 1 58 6.7 70-130 20 04/05/20221745 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 206 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ37130-001 Matrix: Aqueous Batch: 37130 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Chloride 1.0 U 1 1.0 0.25 mg/L 04/04/20221044 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 207 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ37130-002 Matrix: Aqueous Batch: 37130 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Chloride 20 19 1 93 90-110 04/04/20221122 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 208 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ37131-001 Matrix: Aqueous Batch: 37131 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N 0.020 U 1 0.020 0.0050 mg/L 04/04/2022 1044 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 209 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ37131-002 Matrix: Aqueous Batch: 37131 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Nitrate - N 0.80 0.76 1 94 90-110 04/04/2022 1122 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 210 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ37132-001 Matrix: Aqueous Batch: 37132 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate 1.0 U 1 1.0 0.25 mg/L 04/04/20221044 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 211 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ37132-002 Matrix: Aqueous Batch: 37132 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfate 20 19 1 93 90-110 04/04/20221122 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 212 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ37267-001 Matrix: Aqueous Batch:37267 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N 0.020 U 1 0.020 0.0050 mg/L 04/05/2022 1103 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 213 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ37267-002 Matrix: Aqueous Batch:37267 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Nitrate - N 0.80 0.77 1 96 90-110 04/05/2022 1141 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 214 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ37311-001 Matrix: Aqueous Batch:37311 Analytical Method: SM 4500-S2 F-2011 Parameter Result Q Dil LOQ DL Units Analysis Date Sulfide 1.0 U 1 1.0 1.0 mg/L 04/06/20221444 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 215 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ37311-002 Matrix: Aqueous Batch:37311 Analytical Method: SM 4500-S2 F-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfide 10 10 1 100 80-120 04/06/20221444 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 216 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MS Sample ID: XC30013-027MS Matrix: Aqueous Batch:37311 Analytical Method: SM 4500-S2 F-2011 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfide 0.0 10 6.9 N 1 69 70-130 04/06/20221444 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 217 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MSD Sample ID: XC30013-027MD Matrix: Aqueous Batch:37311 Analytical Method: SM 4500-S2 F-2011 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Sulfide 0.0 10 7.7 1 77 11 70-130 20 04/06/20221444 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 218 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MB Sample ID: XQ37761-001 Matrix: Aqueous Batch:37761 Analytical Method: SM 531 OC-2011 Parameter Result Q Dil LOQ DL Units Analysis Date TOC 1.0 U 1 1.0 1.0 mg/L 04/12/2022 0318 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 219 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - LCS Sample ID: XQ37761-002 Matrix: Aqueous Batch:37761 Analytical Method: SM 531 OC-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date TOC 20 19 1 95 90-110 04/12/2022 0331 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 220 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MS Sample ID: XC30013-027MS Matrix: Aqueous Batch:37761 Analytical Method: SM 531 OC-2011 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date TOC 0.0 50 48 1 96 70-130 04/12/2022 0648 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 221 of 279 QC Data for Lot Number: XC30013 Inorganic non-metals - MSD Sample ID: XC30013-027MD Matrix: Aqueous Batch:37761 Analytical Method: SM 531 OC-2011 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date TOC 0.0 50 47 1 95 1.5 70-130 20 04/12/2022 0701 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 222 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: XQ36925-001 Matrix: Aqueous Batch: 36925 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane 3.0 U 1 3.0 1.0 ug/L 04/01/2022 2226 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 108 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 223 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: XQ36925-002 Matrix: Aqueous Batch: 36925 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 51 1 102 70-130 04/01/20221947 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 100 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 224 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ37071-001 Matrix: Aqueous Batch: 37071 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone 10 U 1 10 4.0 ug/L 04/04/2022 2107 Acrylonitrile 5.0 U 1 5.0 0.80 ug/L 04/04/2022 2107 Benzene 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Bromochloromethane 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Bromodichloromethane 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Bromoform 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Bromomethane (Methyl bromide) 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 2-Butanone (MEK) 10 U 1 10 2.0 ug/L 04/04/2022 2107 Carbon disulfide 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Carbon tetrachloride 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Chlorobenzene 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Chloroethane 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Chloroform 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Chloromethane (Methyl chloride) 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 1,2-Dibromo-3-chloropropane (DBCP) 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Dibromochloromethane 0.50 u 1 0.50 0.40 ug/L 04/04/2022 2107 1,2-Dibromoethane (EDB) 0.50 u 1 0.50 0.40 ug/L 04/04/2022 2107 Dibromomethane (Methylene bromide) 0.50 u 1 0.50 0.40 ug/L 04/04/2022 2107 trans- 1,4-Dichloro-2-butene 2.0 u 1 2.0 0.40 ug/L 04/04/2022 2107 1,2-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/04/2022 2107 1,4-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/04/2022 2107 Dichlorodifluoromethane 0.50 u 1 0.50 0.40 ug/L 04/04/2022 2107 1,1-Dichloroethane 0.50 u 1 0.50 0.40 ug/L 04/04/2022 2107 1,2-Dichloroethane 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 1,1-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 cis- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 trans- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 1,2-Dichloropropane 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 cis- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 trans- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Ethylbenzene 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 2-Hexanone 10 U 1 10 2.0 ug/L 04/04/2022 2107 Methyl iodide (lodomethane) 5.0 U 1 5.0 0.40 ug/L 04/04/2022 2107 4-Methyl-2-pentanone 10 U 1 10 2.0 ug/L 04/04/2022 2107 Methylene chloride 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Styrene 0.50 U 1 0.50 0.41 ug/L 04/04/2022 2107 1,1,1,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 1,1,2,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Tetrachloroethene 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Toluene 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 1,1,1-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 1,1,2-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Trichloroethene 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Trichlorofluoromethane 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 225 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ37071-001 Matrix: Aqueous Batch:37071 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 1,2,3-Trichloropropane 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Vinyl acetate 5.0 U 1 5.0 1.2 ug/L 04/04/2022 2107 Vinyl chloride 0.50 U 1 0.50 0.40 ug/L 04/04/2022 2107 Xylenes (total) 1.0 U 1 1.0 0.40 ug/L 04/04/2022 2107 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 98 70-130 1,2-Dichloroethane-d4 106 70-130 Toluene-d8 98 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XC30013 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 226 of 279 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ37071-002 Matrix: Aqueous Batch: 37071 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 120 1 118 60-140 04/04/2022 2006 Acrylonitrile 100 120 1 117 70-130 04/04/2022 2006 Benzene 50 50 1 100 70-130 04/04/2022 2006 Bromochloromethane 50 54 1 108 70-130 04/04/2022 2006 Bromodichloromethane 50 51 1 102 70-130 04/04/2022 2006 Bromoform 50 47 1 95 70-130 04/04/2022 2006 Bromomethane (Methyl bromide) 50 53 1 106 70-130 04/04/2022 2006 2-Butanone (MEK) 100 120 1 120 70-130 04/04/2022 2006 Carbon disulfide 50 52 1 103 70-130 04/04/2022 2006 Carbon tetrachloride 50 51 1 102 70-130 04/04/2022 2006 Chlorobenzene 50 50 1 100 70-130 04/04/2022 2006 Chloroethane 50 49 1 98 70-130 04/04/2022 2006 Chloroform 50 51 1 102 70-130 04/04/2022 2006 Chloromethane (Methyl chloride) 50 54 1 108 60-140 04/04/2022 2006 1,2-Dibromo-3-chloropropane (DBCP) 50 53 1 106 70-130 04/04/2022 2006 Dibromochloromethane 50 46 1 91 70-130 04/04/2022 2006 1,2-Dibromoethane (EDB) 50 53 1 106 70-130 04/04/2022 2006 Dibromomethane (Methylene bromide) 50 52 1 104 70-130 04/04/2022 2006 trans- 1,4-Dichloro-2-butene 50 49 1 97 70-130 04/04/2022 2006 1,2-Dichlorobenzene 50 51 1 103 70-130 04/04/2022 2006 1,4-Dichlorobenzene 50 49 1 99 70-130 04/04/2022 2006 Dichlorodifluoromethane 50 47 1 94 60-140 04/04/2022 2006 1,1-Dichloroethane 50 51 1 101 70-130 04/04/2022 2006 1,2-Dichloroethane 50 51 1 101 70-130 04/04/2022 2006 1,1-Dichloroethene 50 52 1 104 70-130 04/04/2022 2006 cis- 1,2-Dichloroethene 50 51 1 101 70-130 04/04/2022 2006 trans- 1,2-Dichloroethene 50 49 1 98 70-130 04/04/2022 2006 1,2-Dichloropropane 50 51 1 103 70-130 04/04/2022 2006 cis- 1,3-Dichloropropene 50 56 1 111 70-130 04/04/2022 2006 trans- 1,3-Dichloropropene 50 53 1 106 70-130 04/04/2022 2006 Ethylbenzene 50 50 1 100 70-130 04/04/2022 2006 2-Hexanone 100 94 1 94 70-130 04/04/2022 2006 Methyl iodide (lodomethane) 50 52 1 103 70-130 04/04/2022 2006 4-Methyl-2-pentanone 100 100 1 103 70-130 04/04/2022 2006 Methylene chloride 50 51 1 101 70-130 04/04/2022 2006 Styrene 50 54 1 108 70-130 04/04/2022 2006 1,1,1,2-Tetrachloroethane 50 51 1 103 70-130 04/04/2022 2006 1,1,2,2-Tetrachloroethane 50 50 1 99 70-130 04/04/2022 2006 Tetrachloroethene 50 50 1 101 70-130 04/04/2022 2006 Toluene 50 50 1 101 70-130 04/04/2022 2006 1,1,1-Trichloroethane 50 51 1 101 70-130 04/04/2022 2006 1,1,2-Trichloroethane 50 50 1 100 70-130 04/04/2022 2006 Trichloroethene 50 51 1 101 70-130 04/04/2022 2006 Trichlorofluoromethane 50 51 1 101 70-130 04/04/2022 2006 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 227 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ37071-002 Matrix: Aqueous Batch:37071 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,2,3-Trichloropropane 50 49 1 98 70-130 04/04/2022 2006 Vinyl acetate 50 50 1 100 60-140 04/04/2022 2006 Vinyl chloride 50 54 1 108 70-130 04/04/2022 2006 Xylenes (total) 100 100 1 101 70-130 04/04/2022 2006 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 101 70-130 1,2-Dichloroethane-d4 100 70-130 Toluene-d8 101 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XC30013 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 228 of 279 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ37159-001 Matrix: Aqueous Batch: 37159 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone 10 U 1 10 4.0 ug/L 04/05/2022 1058 Acrylonitrile 5.0 U 1 5.0 0.80 ug/L 04/05/2022 1058 Benzene 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Bromochloromethane 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Bromodichloromethane 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Bromoform 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Bromomethane (Methyl bromide) 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 2-Butanone (MEK) 10 U 1 10 2.0 ug/L 04/05/2022 1058 Carbon disulfide 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Carbon tetrachloride 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Chlorobenzene 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Chloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Chloroform 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Chloromethane (Methyl chloride) 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 1,2-Dibromo-3-chloropropane (DBCP) 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Dibromochloromethane 0.50 u 1 0.50 0.40 ug/L 04/05/2022 1058 1,2-Dibromoethane (EDB) 0.50 u 1 0.50 0.40 ug/L 04/05/2022 1058 Dibromomethane (Methylene bromide) 0.50 u 1 0.50 0.40 ug/L 04/05/2022 1058 trans- 1,4-Dichloro-2-butene 2.0 u 1 2.0 0.40 ug/L 04/05/2022 1058 1,2-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/05/2022 1058 1,4-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/05/2022 1058 Dichlorodifluoromethane 0.50 u 1 0.50 0.40 ug/L 04/05/2022 1058 1,1-Dichloroethane 0.50 u 1 0.50 0.40 ug/L 04/05/2022 1058 1,2-Dichloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 1,1-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 cis- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 trans- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 1,2-Dichloropropane 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 cis- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 trans- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Ethylbenzene 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 2-Hexanone 10 U 1 10 2.0 ug/L 04/05/2022 1058 Methyl iodide (lodomethane) 5.0 U 1 5.0 0.40 ug/L 04/05/2022 1058 4-Methyl-2-pentanone 10 U 1 10 2.0 ug/L 04/05/2022 1058 Methylene chloride 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Styrene 0.50 U 1 0.50 0.41 ug/L 04/05/2022 1058 1,1,1,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 1,1,2,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Tetrachloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Toluene 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 1,1,1-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 1,1,2-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Trichloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Trichlorofluoromethane 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 229 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ37159-001 Matrix: Aqueous Batch:37159 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 1,2,3-Trichloropropane 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Vinyl acetate 5.0 U 1 5.0 1.2 ug/L 04/05/2022 1058 Vinyl chloride 0.50 U 1 0.50 0.40 ug/L 04/05/2022 1058 Xylenes (total) 1.0 U 1 1.0 0.40 ug/L 04/05/2022 1058 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 89 70-130 1,2-Dichloroethane-d4 114 70-130 Toluene-d8 97 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XC30013 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 230 of 279 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ37159-002 Matrix: Aqueous Batch: 37159 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 210 N 1 207 60-140 04/05/2022 1008 Acrylonitrile 100 150 N 1 146 70-130 04/05/2022 1008 Benzene 50 48 1 96 70-130 04/05/2022 1008 Bromochloromethane 50 54 1 107 70-130 04/05/2022 1008 Bromodichloromethane 50 55 1 110 70-130 04/05/2022 1008 Bromoform 50 55 1 110 70-130 04/05/2022 1008 Bromomethane (Methyl bromide) 50 57 1 114 70-130 04/05/2022 1008 2-Butanone (MEK) 100 150 N 1 152 70-130 04/05/2022 1008 Carbon disulfide 50 56 1 111 70-130 04/05/2022 1008 Carbon tetrachloride 50 56 1 113 70-130 04/05/2022 1008 Chlorobenzene 50 53 1 105 70-130 04/05/2022 1008 Chloroethane 50 52 1 103 70-130 04/05/2022 1008 Chloroform 50 55 1 111 70-130 04/05/2022 1008 Chloromethane (Methyl chloride) 50 52 1 104 60-140 04/05/2022 1008 1,2-Dibromo-3-chloropropane (DBCP) 50 59 1 117 70-130 04/05/2022 1008 Dibromochloromethane 50 53 1 106 70-130 04/05/2022 1008 1,2-Dibromoethane (EDB) 50 54 1 109 70-130 04/05/2022 1008 Dibromomethane (Methylene bromide) 50 56 1 111 70-130 04/05/2022 1008 trans- 1,4-Dichloro-2-butene 50 53 1 106 70-130 04/05/2022 1008 1,2-Dichlorobenzene 50 54 1 107 70-130 04/05/2022 1008 1,4-Dichlorobenzene 50 51 1 103 70-130 04/05/2022 1008 Dichlorodifluoromethane 50 51 1 101 60-140 04/05/2022 1008 1,1-Dichloroethane 50 57 1 114 70-130 04/05/2022 1008 1,2-Dichloroethane 50 63 1 126 70-130 04/05/2022 1008 1,1-Dichloroethene 50 49 1 98 70-130 04/05/2022 1008 cis- 1,2-Dichloroethene 50 52 1 103 70-130 04/05/2022 1008 trans- 1,2-Dichloroethene 50 52 1 104 70-130 04/05/2022 1008 1,2-Dichloropropane 50 58 1 116 70-130 04/05/2022 1008 cis- 1,3-Dichloropropene 50 57 1 115 70-130 04/05/2022 1008 trans- 1,3-Dichloropropene 50 60 1 119 70-130 04/05/2022 1008 Ethylbenzene 50 53 1 106 70-130 04/05/2022 1008 2-Hexanone 100 130 N 1 134 70-130 04/05/2022 1008 Methyl iodide (lodomethane) 50 51 1 103 70-130 04/05/2022 1008 4-Methyl-2-pentanone 100 130 1 127 70-130 04/05/2022 1008 Methylene chloride 50 54 1 109 70-130 04/05/2022 1008 Styrene 50 54 1 108 70-130 04/05/2022 1008 1,1,1,2-Tetrachloroethane 50 52 1 104 70-130 04/05/2022 1008 1,1,2,2-Tetrachloroethane 50 57 1 115 70-130 04/05/2022 1008 Tetrachloroethene 50 52 1 103 70-130 04/05/2022 1008 Toluene 50 51 1 102 70-130 04/05/2022 1008 1,1,1-Trichloroethane 50 55 1 111 70-130 04/05/2022 1008 1,1,2-Trichloroethane 50 55 1 109 70-130 04/05/2022 1008 Trichloroethene 50 55 1 110 70-130 04/05/2022 1008 Trichlorofluoromethane 50 52 1 105 70-130 04/05/2022 1008 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 231 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ37159-002 Matrix: Aqueous Batch:37159 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,2,3-Trichloropropane 50 59 1 117 70-130 04/05/2022 1008 Vinyl acetate 50 59 1 118 60-140 04/05/2022 1008 Vinyl chloride 50 58 1 116 70-130 04/05/2022 1008 Xylenes (total) 100 110 1 107 70-130 04/05/2022 1008 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 103 70-130 Toluene-d8 92 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XC30013 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 232 of 279 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ37283-001 Matrix: Aqueous Batch: 37283 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone 10 U 1 10 4.0 ug/L 04/06/2022 0957 Acrylonitrile 5.0 U 1 5.0 0.80 ug/L 04/06/2022 0957 Benzene 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Bromochloromethane 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Bromodichloromethane 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Bromoform 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Bromomethane (Methyl bromide) 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 2-Butanone (MEK) 10 U 1 10 2.0 ug/L 04/06/2022 0957 Carbon disulfide 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Carbon tetrachloride 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Chlorobenzene 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Chloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Chloroform 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Chloromethane (Methyl chloride) 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 1,2-Dibromo-3-chloropropane (DBCP) 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Dibromochloromethane 0.50 u 1 0.50 0.40 ug/L 04/06/2022 0957 1,2-Dibromoethane (EDB) 0.50 u 1 0.50 0.40 ug/L 04/06/2022 0957 Dibromomethane (Methylene bromide) 0.50 u 1 0.50 0.40 ug/L 04/06/2022 0957 trans- 1,4-Dichloro-2-butene 2.0 u 1 2.0 0.40 ug/L 04/06/2022 0957 1,2-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/06/2022 0957 1,4-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/06/2022 0957 Dichlorodifluoromethane 0.50 u 1 0.50 0.40 ug/L 04/06/2022 0957 1,1-Dichloroethane 0.50 u 1 0.50 0.40 ug/L 04/06/2022 0957 1,2-Dichloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 1,1-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 cis- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 trans- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 1,2-Dichloropropane 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 cis- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 trans- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Ethylbenzene 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 2-Hexanone 10 U 1 10 2.0 ug/L 04/06/2022 0957 Methyl iodide (lodomethane) 5.0 U 1 5.0 0.40 ug/L 04/06/2022 0957 4-Methyl-2-pentanone 10 U 1 10 2.0 ug/L 04/06/2022 0957 Methylene chloride 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Styrene 0.50 U 1 0.50 0.41 ug/L 04/06/2022 0957 1,1,1,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 1,1,2,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Tetrachloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Toluene 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 1,1,1-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 1,1,2-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Trichloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Trichlorofluoromethane 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 233 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS - MB Sample ID: XQ37283-001 Matrix: Aqueous Batch:37283 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 1,2,3-Trichloropropane 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Vinyl acetate 5.0 U 1 5.0 1.2 ug/L 04/06/2022 0957 Vinyl chloride 0.50 U 1 0.50 0.40 ug/L 04/06/2022 0957 Xylenes (total) 1.0 U 1 1.0 0.40 ug/L 04/06/2022 0957 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 90 70-130 1,2-Dichloroethane-d4 100 70-130 Toluene-d8 96 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XC30013 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 234 of 279 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ37283-002 Matrix: Aqueous Batch: 37283 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 140 1 137 60-140 04/06/2022 0908 Acrylonitrile 100 110 1 112 70-130 04/06/2022 0908 Benzene 50 52 1 103 70-130 04/06/2022 0908 Bromochloromethane 50 54 1 107 70-130 04/06/2022 0908 Bromodichloromethane 50 53 1 107 70-130 04/06/2022 0908 Bromoform 50 52 1 103 70-130 04/06/2022 0908 Bromomethane (Methyl bromide) 50 55 1 110 70-130 04/06/2022 0908 2-Butanone (MEK) 100 140 N 1 145 70-130 04/06/2022 0908 Carbon disulfide 50 48 1 97 70-130 04/06/2022 0908 Carbon tetrachloride 50 50 1 100 70-130 04/06/2022 0908 Chlorobenzene 50 53 1 106 70-130 04/06/2022 0908 Chloroethane 50 45 1 90 70-130 04/06/2022 0908 Chloroform 50 50 1 101 70-130 04/06/2022 0908 Chloromethane (Methyl chloride) 50 57 1 114 60-140 04/06/2022 0908 1,2-Dibromo-3-chloropropane (DBCP) 50 48 1 96 70-130 04/06/2022 0908 Dibromochloromethane 50 50 1 100 70-130 04/06/2022 0908 1,2-Dibromoethane (EDB) 50 58 1 115 70-130 04/06/2022 0908 Dibromomethane (Methylene bromide) 50 54 1 108 70-130 04/06/2022 0908 trans- 1,4-Dichloro-2-butene 50 55 1 109 70-130 04/06/2022 0908 1,2-Dichlorobenzene 50 52 1 105 70-130 04/06/2022 0908 1,4-Dichlorobenzene 50 52 1 103 70-130 04/06/2022 0908 Dichlorodifluoromethane 50 50 1 100 60-140 04/06/2022 0908 1,1-Dichloroethane 50 49 1 99 70-130 04/06/2022 0908 1,2-Dichloroethane 50 51 1 103 70-130 04/06/2022 0908 1,1-Dichloroethene 50 49 1 99 70-130 04/06/2022 0908 cis- 1,2-Dichloroethene 50 50 1 99 70-130 04/06/2022 0908 trans- 1,2-Dichloroethene 50 49 1 98 70-130 04/06/2022 0908 1,2-Dichloropropane 50 53 1 107 70-130 04/06/2022 0908 cis- 1,3-Dichloropropene 50 57 1 115 70-130 04/06/2022 0908 trans- 1,3-Dichloropropene 50 54 1 108 70-130 04/06/2022 0908 Ethylbenzene 50 53 1 107 70-130 04/06/2022 0908 2-Hexanone 100 110 1 111 70-130 04/06/2022 0908 Methyl iodide (lodomethane) 50 49 1 99 70-130 04/06/2022 0908 4-Methyl-2-pentanone 100 110 1 108 70-130 04/06/2022 0908 Methylene chloride 50 49 1 98 70-130 04/06/2022 0908 Styrene 50 58 1 116 70-130 04/06/2022 0908 1,1,1,2-Tetrachloroethane 50 53 1 105 70-130 04/06/2022 0908 1,1,2,2-Tetrachloroethane 50 55 1 110 70-130 04/06/2022 0908 Tetrachloroethene 50 54 1 108 70-130 04/06/2022 0908 Toluene 50 54 1 107 70-130 04/06/2022 0908 1,1,1-Trichloroethane 50 49 1 99 70-130 04/06/2022 0908 1,1,2-Trichloroethane 50 56 1 112 70-130 04/06/2022 0908 Trichloroethene 50 53 1 105 70-130 04/06/2022 0908 Trichlorofluoromethane 50 47 1 94 70-130 04/06/2022 0908 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 235 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS - LCS Sample ID: XQ37283-002 Matrix: Aqueous Batch:37283 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,2,3-Trichloropropane 50 54 1 109 70-130 04/06/2022 0908 Vinyl acetate 50 48 1 96 60-140 04/06/2022 0908 Vinyl chloride 50 58 1 116 70-130 04/06/2022 0908 Xylenes (total) 100 110 1 105 70-130 04/06/2022 0908 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 100 70-130 1,2-Dichloroethane-d4 95 70-130 Toluene-d8 104 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XC30013 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 236 of 279 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: XQ37351-001 Matrix: Aqueous Batch:37351 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane 3.0 U 1 3.0 1.0 ug/L 04/06/2022 2017 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 102 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 237 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: XQ37351-002 Matrix: Aqueous Batch:37351 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 48 1 96 70-130 04/06/20221840 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 121 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 238 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS (SIM) - LCSD Sample ID: XQ37351-003 Matrix: Aqueous Batch:37351 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec % RPD Parameter (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date 1,4-Dioxane 50 53 1 105 9.0 70-130 20 04/06/20221929 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 127 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 239 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: XQ37627-001 Matrix: Aqueous Batch:37627 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane 3.0 U 1 3.0 1.0 ug/L 04/08/2022 2249 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 108 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 240 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: XQ37627-002 Matrix: Aqueous Batch:37627 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 53 1 107 70-130 04/08/2022 2123 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 128 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 241 of 279 QC Data for Lot Number: XC30013 Volatile Organic Compounds by GC/MS (SIM) - LCSD Sample ID: XQ37627-003 Matrix: Aqueous Batch:37627 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec % RPD Parameter (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date 1,4-Dioxane 50 50 1 99 7.5 70-130 20 04/09/2022 0022 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 126 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 242 of 279 QC Data for Lot Number: XC30013 Semivolatile Organic Compounds by GC/MS - MB Sample ID: XQ37155-001 Matrix: Aqueous Batch:37155 Prep Method: 3520C Analytical Method: 8270E Prep Date: 04/05/2022 1500 Parameter Result Q Dil LOQ DL Units Analysis Date bis(2-Ethy1hexy1)phtha1ate 4.0 U 1 4.0 0.50 ug/L 04/07/20221219 Acceptance Surrogate Q % Rec Limit 2-Fluorobiphenyl 82 37-129 2-Fluorophenol 55 24-127 Nitrobenzene-d5 76 38-127 Phenol-d5 62 28-128 TerphenyIA14 96 10-148 2,4,6-Tribromophenol 78 35-144 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XC30013 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 243 of 279 Semivolatile Organic Compounds by GC/MS - LCS Sample ID: XQ37155-002 Matrix: Aqueous Batch:37155 Prep Method: 3520C Analytical Method: 8270E Prep Date: 04/05/2022 1500 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date bis(2-Ethy1hexy1)phtha1ate 40 38 1 95 30-130 04/07/20221244 Surrogate Q % Rec Acceptance Limit 2-Fluorobiphenyl 86 37-129 2-Fluorophenol 79 24-127 Nitrobenzene-d5 92 38-127 Phenol-d5 90 28-128 TerphenyIA14 102 10-148 2,4,6-Tribromophenol 101 35-144 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XC30013 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 244 of 279 Dissolved Gases - MB Sample ID: XQ37390-001 Matrix: Aqueous Batch: 37390 Analytical Method: RSK - 175 Parameter Result Q Dil LOQ DL Units Analysis Date Ethane 10 U 1 10 2.5 ug/L 04/07/2022 0938 Ethene 10 U 1 10 2.5 ug/L 04/07/2022 0938 Methane 2.6 J 1 10 2.5 ug/L 04/07/2022 0938 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 245 of 279 QC Data for Lot Number: XC30013 Dissolved Gases - LCS Sample ID: XQ37390-002 Matrix: Aqueous Batch: 37390 Analytical Method: RSK - 175 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Ethane 550 530 1 96 70-130 04/07/2022 0848 Ethene 520 500 1 96 70-130 04/07/2022 0848 Methane 300 270 1 93 70-130 04/07/2022 0848 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 246 of 279 QC Data for Lot Number: XC30013 Dissolved Gases - LCSD Sample ID: XQ37390-003 Matrix: Aqueous Batch: 37390 Analytical Method: RSK - 175 Spike Amount Result %Rec % RPD Parameter (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Ethane 550 510 1 93 4.1 70-130 30 04/07/2022 0902 Ethene 520 480 1 93 3.9 70-130 30 04/07/2022 0902 Methane 300 260 1 89 3.8 70-130 30 04/07/2022 0902 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 247 of 279 QC Data for Lot Number: XC30013 Dissolved Gases - MB Sample ID: XQ37532-001 Matrix: Aqueous Batch: 37532 Analytical Method: RSK - 175 Parameter Result Q Dil LOQ DL Units Analysis Date Ethane 10 U 1 10 2.5 ug/L 04/08/2022 0947 Ethene 10 U 1 10 2.5 ug/L 04/08/2022 0947 Methane 10 U 1 10 2.5 ug/L 04/08/2022 0947 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 248 of 279 QC Data for Lot Number: XC30013 Dissolved Gases - LCS Sample ID: XQ37532-002 Matrix: Aqueous Batch: 37532 Analytical Method: RSK - 175 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Ethane 550 520 1 93 70-130 04/08/2022 0851 Ethene 520 480 1 93 70-130 04/08/2022 0851 Methane 300 260 1 88 70-130 04/08/2022 0851 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 249 of 279 QC Data for Lot Number: XC30013 Dissolved Gases - LCSD Sample ID: XQ37532-003 Matrix: Aqueous Batch: 37532 Analytical Method: RSK - 175 Spike Amount Result %Rec % RPD Parameter (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Ethane 550 490 1 89 4.5 70-130 30 04/08/2022 0905 Ethene 520 460 1 89 4.3 70-130 30 04/08/2022 0905 Methane 300 250 1 84 4.8 70-130 30 04/08/2022 0905 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 250 of 279 QC Data for Lot Number: XC30013 ICP-MS Metals - MB Sample ID: XQ36687-001 Matrix: Aqueous Batch: 36687 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/02/2022 0252 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony 2.0 U 1 2.0 0.50 ug/L 04/05/20221315 Arsenic 2.0 U 1 2.0 1.3 ug/L 04/05/20221315 Barium 5.0 U 1 5.0 1.3 ug/L 04/05/20221315 Beryllium 0.40 U 1 0.40 0.15 ug/L 04/05/20221315 Cadmium 0.50 U 1 0.50 0.13 ug/L 04/05/20221315 Chromium 5.0 U 1 5.0 1.3 ug/L 04/05/20221315 Cobalt 5.0 U 1 5.0 1.3 ug/L 04/05/20221315 Copper 5.0 U 1 5.0 1.3 ug/L 04/05/20221315 Lead 1.0 U 1 1.0 0.25 ug/L 04/05/20221315 Nickel 5.0 U 1 5.0 1.3 ug/L 04/05/20221315 Selenium 5.0 U 1 5.0 1.3 ug/L 04/05/20221315 Silver 1.0 U 1 1.0 0.25 ug/L 04/05/20221315 Thallium 0.50 U 1 0.50 0.15 ug/L 04/05/20221315 Vanadium 5.0 U 1 5.0 2.5 ug/L 04/05/20221315 Zinc 10 U 1 10 2.5 ug/L 04/05/20221315 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 251 of 279 QC Data for Lot Number: XC30013 ICP-MS Metals - LCS Sample ID: XQ36687-002 Matrix: Aqueous Batch: 36687 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/02/2022 0252 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 100 1 100 80-120 04/05/20221319 Arsenic 100 100 1 101 80-120 04/05/20221319 Barium 100 94 1 94 80-120 04/05/20221319 Beryllium 100 110 1 105 80-120 04/05/20221319 Cadmium 100 100 1 100 80-120 04/05/20221319 Chromium 100 100 1 103 80-120 04/05/20221319 Cobalt 100 100 1 102 80-120 04/05/20221319 Copper 100 100 1 104 80-120 04/05/20221319 Lead 100 98 1 98 80-120 04/05/20221319 Nickel 100 100 1 102 80-120 04/05/20221319 Selenium 100 99 1 99 80-120 04/05/20221319 Silver 100 93 1 93 80-120 04/05/20221319 Thallium 100 98 1 98 80-120 04/05/20221319 Vanadium 100 100 1 101 80-120 04/05/20221319 Zinc 100 110 1 111 80-120 04/05/20221319 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 252 of 279 QC Data for Lot Number: XC30013 ICP-MS Metals - MS Sample ID: XC30013-001 MS Matrix: Aqueous Batch: 36687 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/02/2022 0252 Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 0.0 100 97 1 97 75-125 04/05/20221326 Arsenic 0.0 100 100 1 100 75-125 04/05/20221326 Barium 96 100 190 1 94 75-125 04/05/20221326 Beryllium 0.0 100 110 1 108 75-125 04/05/20221326 Cadmium 0.0 100 96 1 96 75-125 04/05/20221326 Chromium 0.0 100 100 1 100 75-125 04/05/20221326 Cobalt 8.8 100 110 1 98 75-125 04/05/20221326 Copper 0.0 100 100 1 102 75-125 04/05/20221326 Lead 0.0 100 98 1 98 75-125 04/05/20221326 Nickel 11 100 110 1 99 75-125 04/05/20221326 Selenium 1.4 100 97 1 96 75-125 04/05/20221326 Silver 0.0 100 91 1 91 75-125 04/05/20221326 Thallium 0.0 100 95 1 95 75-125 04/05/20221326 Vanadium 0.0 100 100 1 100 75-125 04/05/20221326 Zinc 5.6 100 100 1 99 75-125 04/05/20221326 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 253 of 279 QC Data for Lot Number: XC30013 ICP-MS Metals - MSD Sample ID: XC30013-001 MD Matrix: Aqueous Batch: 36687 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/02/2022 0252 Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Antimony 0.0 100 98 1 98 0.35 75-125 20 04/05/20221338 Arsenic 0.0 100 98 1 98 2.8 75-125 20 04/05/20221338 Barium 96 100 190 1 91 1.4 75-125 20 04/05/20221338 Beryllium 0.0 100 110 1 106 1.8 75-125 20 04/05/20221338 Cadmium 0.0 100 96 1 96 0.18 75-125 20 04/05/20221338 Chromium 0.0 100 99 1 99 0.46 75-125 20 04/05/20221338 Cobalt 8.8 100 100 1 96 1.7 75-125 20 04/05/20221338 Copper 0.0 100 100 1 100 2.6 75-125 20 04/05/20221338 Lead 0.0 100 97 1 97 0.78 75-125 20 04/05/20221338 Nickel 11 100 110 1 96 3.3 75-125 20 04/05/20221338 Selenium 1.4 100 100 1 99 3.3 75-125 20 04/05/20221338 Silver 0.0 100 89 1 89 1.8 75-125 20 04/05/20221338 Thallium 0.0 100 95 1 95 0.34 75-125 20 04/05/20221338 Vanadium 0.0 100 99 1 99 0.89 75-125 20 04/05/20221338 Zinc 5.6 100 100 1 98 0.57 75-125 20 04/05/20221338 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 254 of 279 QC Data for Lot Number: XC30013 ICP-MS Metals - MB Sample ID: XQ36830-001 Matrix: Aqueous Batch: 36830 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/02/2022 0241 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony 2.0 U 1 2.0 0.50 ug/L 04/04/20221454 Arsenic 2.0 U 1 2.0 1.3 ug/L 04/04/20221454 Barium 5.0 U 1 5.0 1.3 ug/L 04/04/20221454 Beryllium 0.40 U 1 0.40 0.15 ug/L 04/04/20221454 Cadmium 0.50 U 1 0.50 0.13 ug/L 04/04/20221454 Chromium 5.0 U 1 5.0 1.3 ug/L 04/04/20221454 Cobalt 5.0 U 1 5.0 1.3 ug/L 04/04/20221454 Copper 5.0 U 1 5.0 1.3 ug/L 04/04/20221454 Iron 50 U 1 50 13 ug/L 04/04/20221454 Lead 1.0 U 1 1.0 0.25 ug/L 04/04/20221454 Nickel 5.0 U 1 5.0 1.3 ug/L 04/04/20221454 Selenium 5.0 U 1 5.0 1.3 ug/L 04/04/20221454 Silver 1.0 U 1 1.0 0.25 ug/L 04/04/20221454 Sodium 400 U 1 400 150 ug/L 04/05/20221144 Thallium 0.50 U 1 0.50 0.15 ug/L 04/04/20221454 Vanadium 5.0 U 1 5.0 2.5 ug/L 04/04/20221454 Zinc 10 U 1 10 2.5 ug/L 04/04/20221454 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 255 of 279 QC Data for Lot Number: XC30013 ICP-MS Metals - LCS Sample ID: XQ36830-002 Matrix: Aqueous Batch: 36830 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/02/2022 0241 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 98 1 98 80-120 04/04/20221458 Arsenic 100 98 1 98 80-120 04/04/20221458 Barium 100 94 1 94 80-120 04/04/20221458 Beryllium 100 98 1 98 80-120 04/04/20221458 Cadmium 100 95 1 95 80-120 04/04/20221458 Chromium 100 95 1 95 80-120 04/04/20221458 Cobalt 100 95 1 95 80-120 04/04/20221458 Copper 100 97 1 97 80-120 04/04/20221458 Iron 1000 950 1 95 80-120 04/04/20221458 Lead 100 97 1 97 80-120 04/04/20221458 Nickel 100 98 1 98 80-120 04/04/20221458 Selenium 100 100 1 100 80-120 04/04/20221458 Silver 100 89 1 89 80-120 04/04/20221458 Sodium 1000 950 1 95 80-120 04/05/20221148 Thallium 100 92 1 92 80-120 04/04/20221458 Vanadium 100 93 1 93 80-120 04/04/20221458 Zinc 100 96 1 96 80-120 04/04/20221458 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 256 of 279 QC Data for Lot Number: XC30013 ICP-MS Metals - MS Sample ID: XC30013-021 MS Matrix: Aqueous Batch: 36830 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/02/2022 0241 Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 0.0 100 99 1 99 75-125 04/04/20221506 Arsenic 0.0 100 97 1 97 75-125 04/04/20221506 Barium 40 100 130 1 93 75-125 04/04/20221506 Beryllium 0.15 100 99 1 98 75-125 04/04/20221506 Cadmium 0.0 100 96 1 96 75-125 04/04/20221506 Chromium 0.0 100 96 1 96 75-125 04/04/20221506 Cobalt 39 100 130 1 94 75-125 04/04/20221506 Copper 1.9 100 100 1 98 75-125 04/04/20221506 Iron 41000 1000 42000 1 89 75-125 04/04/20221506 Lead 0.26 100 99 1 99 75-125 04/04/20221506 Nickel 7.9 100 100 1 95 75-125 04/04/20221506 Selenium 0.0 100 100 1 100 75-125 04/04/20221506 Silver 0.0 100 88 1 88 75-125 04/04/20221506 Sodium 3500 1000 4400 1 92 75-125 04/05/20221156 Thallium 0.0 100 91 1 91 75-125 04/04/20221506 Vanadium 0.0 100 96 1 96 75-125 04/04/20221506 Zinc 4.3 100 100 1 96 75-125 04/04/20221506 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 257 of 279 QC Data for Lot Number: XC30013 ICP-MS Metals - MSD Sample ID: XC30013-021 MD Matrix: Aqueous Batch: 36830 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/02/2022 0241 Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Antimony 0.0 100 98 1 98 1.1 75-125 20 04/04/20221509 Arsenic 0.0 100 98 1 98 0.39 75-125 20 04/04/20221509 Barium 40 100 140 1 96 2.4 75-125 20 04/04/20221509 Beryllium 0.15 100 99 1 99 0.81 75-125 20 04/04/20221509 Cadmium 0.0 100 96 1 96 0.15 75-125 20 04/04/20221509 Chromium 0.0 100 96 1 96 0.26 75-125 20 04/04/20221509 Cobalt 39 100 130 1 93 0.68 75-125 20 04/04/20221509 Copper 1.9 100 99 1 97 0.57 75-125 20 04/04/20221509 Iron 41000 1000 42000 1 78 0.26 75-125 20 04/04/20221509 Lead 0.26 100 99 1 99 0.25 75-125 20 04/04/20221509 Nickel 7.9 100 100 1 96 1.1 75-125 20 04/04/20221509 Selenium 0.0 100 100 1 101 1.9 75-125 20 04/04/20221509 Silver 0.0 100 88 1 88 0.27 75-125 20 04/04/20221509 Sodium 3500 1000 4700 1 117 5.4 75-125 20 04/05/20221207 Thallium 0.0 100 92 1 92 1.4 75-125 20 04/04/20221509 Vanadium 0.0 100 96 1 96 0.29 75-125 20 04/04/20221509 Zinc 4.3 100 97 1 93 3.0 75-125 20 04/04/20221509 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 258 of 279 QC Data for Lot Number: XC30013 ICP-MS Metals - MB Sample ID: XQ37255-001 Matrix: Aqueous Batch: 37255 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/09/2022 0609 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony 2.0 U 1 2.0 0.50 ug/L 04/12/20221143 Arsenic 2.0 U 1 2.0 1.3 ug/L 04/12/20221143 Barium 5.0 U 1 5.0 1.3 ug/L 04/12/20221143 Beryllium 0.40 U 1 0.40 0.15 ug/L 04/12/20221143 Cadmium 0.50 U 1 0.50 0.13 ug/L 04/12/20221143 Chromium 5.0 U 1 5.0 1.3 ug/L 04/12/20221143 Cobalt 5.0 U 1 5.0 1.3 ug/L 04/12/20221143 Copper 5.0 U 1 5.0 1.3 ug/L 04/12/20221143 Lead 1.0 U 1 1.0 0.25 ug/L 04/12/20221143 Nickel 5.0 U 1 5.0 1.3 ug/L 04/12/20221143 Selenium 5.0 U 1 5.0 1.3 ug/L 04/12/20221143 Silver 1.0 U 1 1.0 0.25 ug/L 04/12/20221143 Thallium 0.50 U 1 0.50 0.15 ug/L 04/12/20221143 Vanadium 5.0 U 1 5.0 2.5 ug/L 04/12/20221143 Zinc 10 U 1 10 2.5 ug/L 04/12/20221143 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 259 of 279 QC Data for Lot Number: XC30013 ICP-MS Metals - LCS Sample ID: XQ37255-002 Matrix: Aqueous Batch: 37255 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/09/2022 0609 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 100 1 103 80-120 04/12/20221147 Arsenic 100 110 1 105 80-120 04/12/20221147 Barium 100 100 1 103 80-120 04/12/20221147 Beryllium 100 100 1 102 80-120 04/12/20221147 Cadmium 100 100 1 101 80-120 04/12/20221147 Chromium 100 100 1 104 80-120 04/12/20221147 Cobalt 100 110 1 106 80-120 04/12/20221147 Copper 100 110 1 107 80-120 04/12/20221147 Lead 100 100 1 101 80-120 04/12/20221147 Nickel 100 110 1 107 80-120 04/12/20221147 Selenium 100 100 1 105 80-120 04/12/20221147 Silver 100 94 1 94 80-120 04/12/20221147 Thallium 100 98 1 98 80-120 04/12/20221147 Vanadium 100 100 1 102 80-120 04/12/20221147 Zinc 100 110 1 107 80-120 04/12/20221147 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 260 of 279 QC Data for Lot Number: XC30013 CVAA -MB Sample ID: XQ36797-001 Matrix: Aqueous Batch: 36797 Prep Method: Analytical Method: 7470A Prep Date: 04/01/2022 0324 Parameter Result Q Dil LOQ DL Units Analysis Date Mercury 0.00020 U 1 0.00020 0.000091 mg/L 04/01/2022 0757 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 261 of 279 QC Data for Lot Number: XC30013 CVAA - LCS Sample ID: XQ36797-002 Matrix: Aqueous Batch: 36797 Prep Method: Analytical Method: 7470A Prep Date: 04/01/2022 0324 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Mercury 0.0020 0.0018 1 91 80-120 04/01/2022 0800 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 262 of 279 QC Data for Lot Number: XC30013 CVAA - MS Sample ID: XC30013-002MS Matrix: Aqueous Batch: 36797 Prep Method: Analytical Method: 7470A Prep Date: 04/01/2022 0324 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Mercury 0.0 0.0020 0.0018 1 89 80-120 04/01/2022 0813 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 263 of 279 QC Data for Lot Number: XC30013 CVAA - MSD Sample ID: XC30013-002MD Matrix: Aqueous Batch: 36797 Prep Method: Analytical Method: 7470A Prep Date: 04/01/2022 0324 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Mercury 0.0 0.0020 0.0018 1 91 2.2 80-120 20 04/01/2022 0816 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 264 of 279 QC Data for Lot Number: XC30013 CVAA -MB Sample ID: XQ36798-001 Matrix: Aqueous Batch: 36798 Prep Method: Analytical Method: 7470A Prep Date: 04/01/2022 0324 Parameter Result Q Dil LOQ DL Units Analysis Date Mercury 0.00020 U 1 0.00020 0.000091 mg/L 04/01/2022 0931 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 265 of 279 QC Data for Lot Number: XC30013 CVAA - LCS Sample ID: XQ36798-002 Matrix: Aqueous Batch: 36798 Prep Method: Analytical Method: 7470A Prep Date: 04/01/2022 0324 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Mercury 0.0020 0.0018 1 89 80-120 04/01/2022 0933 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 266 of 279 QC Data for Lot Number: XC30013 CVAA - MS Sample ID: XC30013-025MS Matrix: Aqueous Batch: 36798 Prep Method: Analytical Method: 7470A Prep Date: 04/01/2022 0324 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Mercury 0.0 0.0020 0.0018 1 88 80-120 04/01/2022 0941 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 267 of 279 QC Data for Lot Number: XC30013 CVAA - MSD Sample ID: XC30013-025MD Matrix: Aqueous Batch: 36798 Prep Method: Analytical Method: 7470A Prep Date: 04/01/2022 0324 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Mercury 0.0 0.0020 0.0018 1 89 1.1 80-120 20 04/01/2022 0944 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 268 of 279 QC Data for Lot Number: XC30013 CVAA -MB Sample ID: XQ37214-001 Matrix: Aqueous Batch: 37214 Prep Method: Analytical Method: 7470A Prep Date: 04/06/2022 0228 Parameter Result Q Dil LOQ DL Units Analysis Date Mercury 0.00020 U 1 0.00020 0.000091 mg/L 04/06/2022 0510 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 269 of 279 QC Data for Lot Number: XC30013 CVAA - LCS Sample ID: XQ37214-002 Matrix: Aqueous Batch: 37214 Prep Method: Analytical Method: 7470A Prep Date: 04/06/2022 0228 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Mercury 0.0020 0.0020 1 99 80-120 04/06/2022 0513 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 270 of 279 QC Data for Lot Number: XC30013 Chain of Custody and Miscellaneous Documents Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 271 of 279 PACE ANALYTICAL SERVICES, LLC Ps Si P a e iK ' . i a•...1 .. —:c �r � . .} Ay G 888iii t L'.. L9'' . .4. u.. .. �.;p H. . . ..M .aa.a a s..:':..: .. Fr :Yk 24 43 .121 3 y m T o c — Ll n ri $ O 4kk — m x c C�r.. . U i_ oe o � S Y ti o t— q V $ z ' I a 'c k 4d ar'_i ll v p } IL ❑ ipppi. .emu 22 f I N 13 s r- { [ LLa C�. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 272 of 279 PACE ANALYTICAL SERVICES, LLC y t 13 F1 u 3. 7777, aj JAq Lp µ� N dz F m =r m ;v m y� 4 $ TM v F- r- H 0 b. l C b m Y �7 ❑ k go d s iME ME■ -'-II1`1 , w S4 4 yR l} } L L.r1 S' Cd ' - a dL .' A Pac, 106 Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 273 of 279 PACE ANALYTICAL SERVICES. LLC h # - L J� L/ 44 1.3 3 U. a.. [p.'H %4 Q9 '1 r U�:3rF.� .2 .. •• 1'llf"': �'y. 5 — •L' I: ��a-.,a.,y�T:�_r �Y�;�p��'�'.t[�''.'�����ji':�j:.�;j'S�edd�• � :' T, •�; i r �.:.. 7e, 13 do o G a rt �..� . 13 .3 �: I n 3 :a 1p 0 44 4 ]IT I N 2 °a 6 f�6 t} v E 5 c Sn 5 I 5� } .1 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 274 of 279 PACE ANALYTICAL SERVICES, LLC Iy � x *5Gy'r�]' �.�,t J4 - .. I..I :.I .I• I 8„ '�ryy. (�I `, �:y.�k•I. i a zn 11 y Imo" = 13 v wl y s. y i'IA IA:' rr I.~ C ...' a! '� a .T 77,77-77 .. '.. gel jay ���' 77 f. vac �1}�� `12•�I� �� ��1��1!'�a .:q ' �Srli � Im :. .. .. .. �. • ' .:. •'..: .' : 2 n� I� .. .. .. .. ... li 5 � I LSO .;•:. . -1 � i +•. '. r •?.' ax a b E E 4y l U *� a o- Y�.` •a n IT 2 ..E 44 �• J � 5 } I I 2i 1 %LI �k - ;3 ill _ Iy J r4 41 S 7C A GS SGC "4 �n k ei tV) lYII yG. IN Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 275 of 279 PACE ANALYTICAL SERVICES, LLC � C �' � F � •• � {Y} � . � � is � � � I � I�_. � �'.� ��'� .. pi i. �91�a��. Nf�JI Lr4�?� 1 ..j u ea u Os,; U Izl'a. . • X. •J} 17 n 3 {I E z '��zy r-rw•°'n'` ti P'i"�°" 1 a: �j t SjC+ !ti 1 � C'4 �{ �: �. L LJ V _ S 4i I- ai E vrj J y � m M ."+7, 9 Y V W I r in :...u. ; V u LU e, U d . I ! ti £ $ o 1 t5 L ?Z LLd yet i o f i m I c 1 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 276 of 279 PACE ANALYTICAL SERVICES, LLC Samples Rrceipt Mecklis[ (SRC}(MEOOI&C-15) RoAwr]:9l VIM c 4naJy7lcaJ Issuing.wthorlty., Pace ENV - WOOL p• • e 1 or 1 ample Receipt C hecklist ( RQ O[ien[, r'DM CocJcr 3nspmcd byldatc: TTG 1 MOG2C23 LOLlk ?Cij0013 MCclnti 0rMCI-!i:;t: µalc T- UPS Jt FedE,x fJtllel" - - ' yos T c5 1. Were CtCat13dw Seals przsant an tho cooler r ---- -- Yeis I I'M) I tANA 12. 11-vusuad seid�j -.vurc reqffls� wens t intact a1t3 unlvoken'' E•I Srrip [I]: 31-0-42 _ chlarine snip 11): NA T'estcd by; TK: rigina] temperature upon receipt! Derived (UoiTected) ternT:u3 m upon receipt L�Anlid Snap„twup ID: AA 2_45 r 2.6 aC NA NA 9C NA 1 NA oC WA l NA 317. b1et11L>'d:[al-cmp�ratureBUA I❑Againa4ButIls 1RC,un11D; S IRCrL13CorrecCimFttclor. _"C Mothod of coolant; 0 wet Ice 0 lce Packs ❑ D ]cc 0 Nono _ ,. I f lcrrp,�Tr l--im rpf imy conker exceeded 6_011C_ was ProjeCl_ Marwger Nod NO ❑Yeg DNo �]NA r� wsc; NuliCcd kay: pll0ue i crnaill fol:e-Lc' (circle [tire). J Yes LJ Nu 111A 4. Is the comtmel•raal ccwraer'3 packing slip artarhPd to this farm? --- -- I+ Ives -No 15. wu properomtkv prorAures WAOWOd? V Y eS IJ Yit (3. Were SarnpLe 103 ILS_e0 OLl the 1-k-K .r 7, Were sample ID3 lined on all sampl400ntaincm? V YC3 ❑NOS Yex Nol Jc� 3. Was cnlion date & time Jisred oll the COC7 9. Was collection date &. time listed ou all sample cantn-nws? : Did a.] ecntainer LabeL inlo"atibn (€D. (ine, time) agree with the { OU..' _YesLj.%401 'Yes ]0I { Yes No- : I _ Wert. ItmLs tit br [aert0r11c:l IiALd ou ilie CCC? ' 1 _ Did a 119amplr.s errive in the pruper cuntairrers Air ouchi,:st aadiu, in gc od pond idcil �, etu.) , (uLtbrDkeu, lids on, 7 0 YC3 ❑N0I L,KjYr,,l LJNo 113, Was adlc um& sam ]L volume avai.abl%O . Yrny Nit 14. Were all saw-ples received within 'A the holdingtime 0r 48 hours, whiCbmvar Domes [In'? Ye,3 F ' No 15, WGL any WZPP',C;5 GQn�iner$ mi2�,bng=6% (circle one) gam les Not listed on COC? 0N0 � 16, fp_� VOA alyd RSK-'75 ganple%, were bm, bubbles present "pee -size" (W'or 6 in diameltr) El YeU N�4 iu auy uFlhc VOA 6410 RLye;_� No NA 17, Weeall DRO,YnetalrAutriemt sams las weived v a pH No , NA 1 L WM all Cy]Liit1C s&-n les retelved Lit H'> l2 and sulfide samples Mewed at a PH > 9V I9_ Were']1 applicable NIT1r7GNlrcyanide?plieriolf625,IrfH.3 (< 0.5 ) satr,p os oc o n Yes ❑No ❑✓ A1�i , , _ Y=rns ❑ N� ❑J N� 2U. Vt'c:-G ulictlt r41nKr�SSirr ;'Pe�LS (i_e. tr�[µvsjed dilutions, (w1�17r1;Si3 designatiors_ mac__L.) egOy transcribed from tine COC ini0 the 00rnrnent section in LIMS? Yes >{ Np 21 _ W;m the €Lllx r:urober limb-d 43:1 11M CCMItUiIM' IANIA4 mplePreserv„tian (14lustbe crunplctra CorEuiy Stsrnrl(s) iltcgrrectly preserved or�vitls neadspaca.j mple(5) Ni ..._ ._ - ' w ei a re€eive6 inrarrgrfly prt; served wd were adjusted accordingly sEmplc Tr cciviu1 a with NA mL of airelk: 031e: H2SO4, HNQJ, HCI, NaOkl using A f m� of prcactvaton NA Lf mom than one preservative is tteedde please no-e in ilia comments below. ampl ,(s) NA -. --.-- wem rerriv+trt wiih hidlhleA >6 mni In iriamctzr, ]alrnples(q WA _ _ - were received with TKC �- M mg/L (I: P19 is me) Ai id tiVare adjusted acccrdinglp- in sample receNin?, with sodium thiosiilfa (Na2S2 1,) %uith Sealy ID: 3 R barcodo labols applied by; TEC Late: 11,61011272.2 C'n7nmeL•Lt�: Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 277 of 279 PACE ANALYTICAL SERVICES, LLC Sarnples Recalpt Checklist (511C) (MEMI IRC-15) Revised.9129/2026 Issuing Authorlty_ Pete ENV - WCOL Page 1 of 1 Sample Receipt Checklist (RQ Clicut. CDM Smrrh Cooler In eeLed 1duLe; IEC r C&M-2022. Lot # }i ifr{hl3lx[:3iar2� Means of receipL_ Lj Puce 'Ucrit I 11mUllb L,!j FcciLx Lj Other Ye€l 1,/INLIJ I 1- Wffe C.usCad y seals prestrit on Lh�-o;tpulrr> EJY-esl EN01NA 2_ Tf cuRGti[j scaly were xi esent, were they JI]taCL aril unbml en? pH Ship ID; Chloriae 5Lri1a TD: 21-151 MIMCStcd b}^ � "r original tcmporaturc upon mceipL r Derived (Ccim ltd) tcn„perat431mc upon receipt %5,olid Snap-C.up iD= `t oC+ 3.0 ;10 cC NA rNA �c 1:A Ti „C Meth{K[= OTernperattrro Blank against Bottles 1R Gun TD: 1K (itm C:oircctian Factorm '1 0(- McthQd of coolatn, ❑ wLt Ice ❑ Tce Packs E1T)EyTW ❑ None Yes ❑ No ❑ 1*A 3, If tc-ruperatme of any cnnler exc=hIcAl �4,{1°t , WS PTojC aaua. N ger Notified? Y[4S was Notified b,v_ plruise? ei]aui] ? luurlLa-Guc fcsrcic e(Ltic), Yes 1*o J 7ti,A I is the oouunei+cial courier'; pLwkiitg slip Wuwh�>d to this fbrm' 3. Wereprbper tur;Lt,dy prooe dum5(rolingnished.+received) l011D �exl? ,/ Yes No Yes X41 6M were temple ML, RIA on the COC'? ?. Were sample 1T)s li�rt>,d on a:l sample containers? 6. Vdas cnlleClitan date $ tiinc fisted on the CQC' - Yes ❑ No J Yea No ED Yev Ll No 9_ Wuw ckillecfon. d= & time listed on all sarnirle torYtznncm? J Yex K(1 I n_ Dili all cunlainy labkJ information (1D, date, tirna} al Tee with the C'OC m! 1'ew tau I l_ V4'+�ru t:�ix to bo performed listed on the {CDC'? Y ❑ No 12_ Did all sMplcs arriwc in the proper contaiaem Jmrar tac:h tc,-,t andr'or in Scrod oandition (un€ mken, lide tm, etc.)? ❑d Yes NL) 13_ Was adequate arnplc, volume aw iilablc'? Ej Y o 14_ Welt all sarnplC5 1VVQitxxl within �4 the holding time nr 4R hnurg, wbiohcvcr ccuies f isi? cs V 13, Wcrcany € rnplesoonIainers m-55i xcess circle one) sarn 1esN. QL R5led on CO ., Yts ❑ Ala NA 16. Fur VOA and RSK-175 sample.;, were a 11;5 pm5ont-"peMize"(mm/,"or6nirn in dirumwrm) in any of the VOA vials? � Ycs No NA i ?. Were all DRCllm�tals?nutriont samples received ELL ct H of :� 2m. 5f Yc'A lk{t• I R. Wm all cymiide sans ies received uL u. ply - 12 and ndfi is samples receimved at a pH > 9-y of Yes ❑ NNo❑ 19. Were all :rem 1K plica Nl7is; N!cyaniLWVhtniolj6'21 11608 3 (< 0.5mSiL) sample€, tree 4o-F residual chlorine" ❑Yes El ❑d NA 20. Wuc client re marks! requ@Rn LS (i-. re�j yUC5tcd dilutions, SiMSDdusignq(ium, etc...) corrcctlytmriuribad imm 1he CO-C into the comment sectiurt in 1,1N4S? -f es + No 21_ Was t11 e g unto nurrtbur lisUxl on ;he cominer label? if yes, On(itu iu Snmple Pi ervation (P&st be cuusJxleLc;1 Cur any. samplc(s) incorrectly pre.,,arved or with hcaadsl)ace,) Sample{s) �A w lr rcLXivud inwrrL; ly preserved and were adjulstcd n000rdingly in sample receiving wish hA n L of cimile one: TT]904, HN(;, HCl. NaOlml using ,R * NA Time of pf%,%er%maLi(in NA lfinore ttian Hite preservnh vc i5 needed, please none in diu cum rn 4ntq biJow, Crtrtipl Cl were received with bubbles >6 nim in di4vu�l4r. Samples(s) N,^ wore romivred with TRC s- 0 J ln6"'1, (T144l9 is nu) and were adjusted acrumTdingty in sample receiving with �udittm thins LINO (Na,S,Omj) with Shealy TT3; [ A Ft barcc.de l xbels appli(;4 by; T� T)atrr; 03 W2022 l.'Aniinenth=A ffama Chl r Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 278 of 279 PACE ANALYTICAL SERVICES, LLC Samples Re" IptChedtllst (SFEC) �MEM019C-1S) RLbv sPc:912912020 J Ctrfl,7d!}d 7f I�,suing;Aulhurily: Pace ENV- WCQL Page 1 of S Sample Receipt Checklist ( R C]ienL; CDNf& ith C[xi1orTn•ricl:Ledby/dujt!: TL-C r 03r3L'2A2,2. Lot4: XC30013fKC30021 2% M[com ofmcipt El 1%wc ('I'Mml Ul'4 L!j fodEx Lj officr. — ��'Yoj M1,01 1. W8M CLLAOdy seals fklera L On Lhe "Ier? Yex,I UN(ij ,O ETA 2.,1f cu sto sews ware presem, were they itnact and unbivken? 'R 51rip TT): � I ss2 Ch brine Strip ID: N.h 'bested by: TFC Original wmpnrxnjro iLjrmi rrWipl; r 1)m-ivCd ((:orrQUI;pl) tCmperatturc upon rcMpt ° aSolid Snap-C:up M: NA L.3 ++1-3 ,C 13 -.i I „C 3.9 LC NA rTtiA uC — .Method: ❑d Ternpemmit Blank [:]A IW'L T30k'lew TR Ciw, Ti: TR Crun C,arrculiLn Ymlor; 0 LI Method of'coolant: ❑ wet. Tee Tee Packs ❑ 2a T,. ❑ None ❑ 1 cs ❑ 1*o Q lr 3- If temperature of any cooler exceeded fi.17=C', wwr l roj cct Nfs,nsr r Nrrtificd" PM was l*o6fied tw: p]wna,` email r' Jacc�tu-1acc (c:irc6e onu), Yt!m N Nr 4- Is the commercial COUJ'ier's packing slip ULLLWILed Lek this FUTM? Yes S- Were j5i,5jr eukir}dy la7t,lr rdisr-rew (rrlinui�hc'ecccivcd) follawed'2 YC$ y1*o No 6- Wrrr !4}impIr TT)s listed on the CSC? . Yes ❑ No ?- Were eerrlple TT}ti listed un all 5wWk ccutainuO d Yes EFNo S- W1*. cr,lleclio„ date & time listed on the COO? ❑,/ Yes No 9. Wasoollcclioudare &dine listed on all sample contamers? 1'es TTr� lU. L}ida11 container label intnrmaricra7 (IT), r1 Lime) s,t�eewitltithc CO(? rz Yes -NL) 11. 1b'ere tes,s to be perratotied lilted MI the MCI? Q yes ❑ors 12, Did all samples mirivc in the proper containers for e: ch Lest andiur in grxK1 conditicn, (unhrx,ken, lids rm, cr,)? d Yes '+kr 13. Was adequate sample tialutne rrvrrile,blc ? Lot c , 14. Welt all saolgsles I-eutivml wil}rirr t Lhc .g timc or 48 hours.1vhich1ZVel' comets firar' es lj 15. Were any €.xnples containers rni�win (cirrlo vnc) samples Not listed on CDC:'' ❑ N 16. For VUAand R5K-1 75 sampleei, were huhhles prehent."pea-si c:" (!/4"-DI Gnu_, ill diameter) Its any of the V0A Vials? 7 Yes.' N,, LJKA 17. Were all DRC)rm--falcnun;cnt samples recaived at a pH od- 2? 0 Ym Ala NA 1 S, Wcrc all cyanide samples received at a 1T> 12 acid %ulEl`ee tian,p144 ruwivcd xt a pH > ❑ 'es ❑ Flo ❑d NA I q. Were a,ll a R-11ia~0 c NH,r i'KN?cyam p eno '62.5-]l608-3 {•:: 0-5133gj.) 5arnplQ; Crc ; of ICSliltlal ClllO[Jlle'! ❑ ❑ No ❑d NA 21.t, Wcrc Oisnt j%_,marks mquenq (i.e- requesied dillLIJCM6, ld%MSD €icsignatirnis_ etc...j con•ectly transcrihed fmttl the MC iinw 1hz Porum:,at scctiant L LJ.[ S 1(4y ., Vic, ? ]. Wo-s Lbe u{FLc nu:nl--r lj jvA on IL container lab07 Jf Y-es, (write 5almpJle Preseavatioa (Muv be UAYLplettd liar uny- .,Wnplu(s) incorrectly prcscrvcd or with Jieadspace.) Sample(i;) --were received inct)rrenly prvwrv-;:d wnd wL:w adjusttk?ccondin by iri .gatnple receiving with inL of oirde one: 132S ; I1NO3, TTCI, NL0H wing SR 4 NA Tlriw of prusL'1 yuii0n 'NA If uiorc than one prase rvative In rle- cId6d, p1mL,;e note iR the comni on 3 belrnv. satnple(s) NA w�zc moeii'od with bubbles >6 n,m irk diatneLer. 9arrsples(s) W were 1%meived with TRC > D_!{ nig.,L (Tf # J 4 is no) and were a djusled accc,nlingly in. sample rocciving whii radium diiosulfate (Na2&, 3) wikh Shw; y hu; NA 3R barcode labels applied by: I[C Uatc; MO l 2022 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 279 of 279 aceAnalytical Report of Analysis CDM Smith 5400 Glenwood Avenue Suite 400 Raleigh, NC 27612 Attention: Mathew Colone Project Name: North Wake Unlined Landfill Lot Number:XC30022 Date Completed:05/24/2022 05/25/2022 12:00 PM Approved and released by: Project Manager II: Cathy S. Dover =w�q a[cArFo f� /747iR TN I AM Nauvue Acm^r mn BuaN 11 � eOfFAi� A C C R E D I T E D TESTINGL aORlTOAY The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 1 of 19 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative CDM Smith Lot Number: XC30022 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Where sampling is conducted by the client, results relate to the accuracy of the information provided, and as the samples are received. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved The NELAC Institute (TNI) standards, the Pace Analytical Services, LLC ("Pace") Laboratory Quality Manual, standard operating procedures (SOPS), and Pace policies. Any exceptions to the TNI standards, the Laboratory Quality Manual, SOPS or policies are qualified on the results page or discussed below. Pace is a TNI accredited laboratory; however, the following analyses are currently not listed on our TNI scope of accreditation: Drinking Water: VOC (excluding BTEX, MTBE, Naphthalene, & 1,2- dichloroethane) EPA 524.2, E. coli and Total coliforms SM 9223 B-2004, Solid Chemical Material: TOC Walkley-Black, Biological Tissue: All, Non -Potable Water: SGT-HEM EPA 1664B, Silica EPA 200.7, Boron, Calcium, Silicon, Strontium EPA 200.8, Bicarbonate, Carbonate, and Hydroxide Alkalinity SM 2320 B-2011, SM 9221 C E-2006 & SM 9222D-2006, Strontium SW-846 6010D, VOC SM 6200 B-2011, Fecal Coliform Colilert-18. The following dissolved metals samples/elements were taken off -hold by the client: • MW-5R: cobalt • MW-9: cadmium • MW-34: chromium • MW-36: chromium If you have any questions regarding this report, please contact the Pace Project Manager listed on the cover page. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 2 of 19 PACE ANALYTICAL SERVICES, LLC Sample Summary CDM Smith Lot Number: XC30022 Project Name: North Wake Unlined Landfill Project Number: Sample Number Sample ID Matrix Date Sampled Date Received 001 MW-32 Aqueous 03/29/20221455 03/30/2022 002 MW-28 Aqueous 03/29/20221705 03/30/2022 003 MW-28d Aqueous 03/29/20221720 03/30/2022 004 MW-35 Aqueous 03/29/20221630 03/30/2022 005 MW-5R Aqueous 03/30/2022 0905 03/31/2022 006 MW-34 Aqueous 03/30/2022 0940 03/31/2022 007 MW-9 Aqueous 03/30/20221030 03/31/2022 008 MW-36 Aqueous 03/30/20221100 03/31/2022 009 MW-23 Aqueous 03/30/20221255 03/31/2022 (9 samples) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 3 of 19 ICP-MS Client:CDM Smith Laboratory ID:XC30022-005 Description: MW-5R Matrix: Aqueous Date Sampled:03/30/2022 0905 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/24/2022 0424 BPK 05/22/2022 1118 42559 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Dissolved Cobalt 7440-48-4 6020B 19 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 4 of 19 ICP-MS Client:CDM Smith Laboratory ID:XC30022-006 Description: MW-34 Matrix: Aqueous Date Sampled:03/30/2022 0940 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/24/2022 0503 BPK 05/22/2022 1118 42559 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Dissolved Chromium 7440-47-3 6020B 3.6 J 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 5 of 19 ICP-MS Client:CDM Smith Laboratory ID:XC30022-007 Description: MW-9 Matrix: Aqueous Date Sampled:03/30/2022 1030 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/24/2022 0525 BPK 05/22/2022 1118 42559 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Dissolved Cadmium 7440-43-9 6020B 6.4 0.50 0.13 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 6 of 19 ICP-MS Client:CDM Smith Laboratory ID:XC30022-008 Description: MW-36 Matrix: Aqueous Date Sampled:03/30/2022 1100 Project Name: North Wake Unlined Landfill Date Received:03/31/2022 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/24/2022 0533 BPK 05/22/2022 1118 42559 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Dissolved Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 7 of 19 QC Summary Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: XC30022 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 8 of 19 ICP-MS - MB Sample ID: XQ42559-001 Matrix: Aqueous Batch:42559 Prep Method: 3005A Analytical Method: 6020B Prep Date: 05/22/2022 1118 Parameter Result Q Dil LOQ DL Units Analysis Date Dissolved Cadmium 0.50 U 1 0.50 0.13 ug/L 05/24/2022 0409 Dissolved Chromium 5.0 U 1 5.0 1.3 ug/L 05/24/2022 0409 Dissolved Cobalt 5.0 U 1 5.0 1.3 ug/L 05/24/2022 0409 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 9 of 19 QC Data for Lot Number: XC30022 ICP-MS - LCS Sample ID: XQ42559-002 Matrix: Aqueous Batch:42559 Prep Method: 3005A Analytical Method: 6020B Prep Date: 05/22/2022 1118 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Dissolved Cadmium 100 100 1 103 80-120 05/24/2022 0417 Dissolved Chromium 100 110 1 107 80-120 05/24/2022 0417 Dissolved Cobalt 100 110 1 108 80-120 05/24/2022 0417 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 10 of 19 QC Data for Lot Number: XC30022 ICP-MS - MS Sample ID: XC30022-005MS Matrix: Aqueous Batch:42559 Prep Method: 3005A Analytical Method: 6020B Prep Date: 05/22/2022 1118 Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Dissolved Cobalt 19 100 120 1 105 75-125 05/24/2022 0432 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 11 of 19 QC Data for Lot Number: XC30022 ICP-MS - MSD Sample ID: XC30022-005MD Matrix: Aqueous Batch:42559 Prep Method: 3005A Analytical Method: 6020B Prep Date: 05/22/2022 1118 Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Dissolved Cobalt 19 100 130 1 106 0.98 75-125 20 05/24/2022 0440 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 12 of 19 QC Data for Lot Number: XC30022 Chain of Custody and Miscellaneous Documents Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 13 of 19 PACE ANALYTICAL SERVICES, LLC M. 13, 0.�4 .6. Ch sm tlFtlFtlF \ + _ a � ~ _ z u �+ w v ° a "' �'. a a S „ as o n I ' -1Ex 4 SJ 15 g _ _ af 22 LQ w w W Cl Sz,a Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 14 of 19 PACE ANALYTICAL SERVICES, LLC Lj 4 U T ni F'A Mill ,gym siim�T Cl) V El R: .777 �-j 7.1 .j Cj ILI P A: I z E 1 1) T- V -64 A Pff Lr �d 2 7 cr.) Page 15 of 19 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com PACE ANALYTICAL SERVICES, LLC q .i: E. ZZ:�.., :•. Fu ri 7. C .I K i` v - '�S _ 4 ii�: 77+ti.y}:r' l•.;C xj S'..1-`::: A: 7. y I .����.. 7#' t�.:�j'.:lktG?�J41�f±.'!4�a."'�'YfW''�Q3'4o��� �:.. .•.: : �e". � a. `. :. R -,Lrta z 8 3 3 0. raj r F A �..] a a . - o c i E _ - A LF '5 l rw All ►n G z a ° � h Ll y� l AR � _ v J y wl r+ u G H _.. I '*' v �i r- E N+ F a fi „ Q� a Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 16 of 19 PACE ANALYTICAL SERVICES, LLC � � �+ { � � �. •.. ,�_' �: � � �. f is H'ii .il :r? il` .C:. L M1i ' �'• V Sil 4 G':0' ' I:: M.' F 6 L4'9 'y 4 `a L7 {I _: I.. .FI y . L,1 ,1� U L1 Ga u di *! . L } . Q T yyW, H � m � � �•'�� 11 n� r� iL _ E E fff~QQQ 0 III L,yI�_ E m I Lk �I r>1 a 4 'Y V i iV hi O 165 LJ L 1 w w.L7 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 17 of 19 PACE ANALYTICAL SERVICES, LLC /W2,4r1y'r+ C:lienc C,'I]1ti:iiln Samples Mineipt Chg!tklist I5RC) (ME041SC-15) Issuing AuLhori ty: Pace ENV - WCOL Sample Receipt Checklist (SRC COL)II27 l'n�PL.4Sj�I.I bw:'dtatc; TEC r 113r1:�M%)22 Revised:9/29/2 zo Page Iof1 Vt!LInv a f rcx Qi PL; D [1E1" ('Jilt U13S FedL'x Other Ely"I FIN01 j I. Rfcl,c uuwlr,dy 4cltly m-:Pn[ oB the cooler:' LjYesl FTNolNA 2, if custody seals were regent, were Lhey inla t and unbMkcrl? pH Strip ID, ii Chlorine Strip ID; 21 _54 Tested by. Trc Driginal remperanim upon reocipl.r" Tkrivmc (C'.n rde d) mnlperatara upon. receipt �oSolid Srllp-Cup TT): NA 1.9 111-9 = .#.0 l31) uU 7.4 r1;A .-C NA NA c(• &Iwhod: ['Temperature 131anlc ❑t a-11UL Tlotllm TR Chin lit Gull Coritction Faeu,r: t' °C Method otcoolant: ❑J Wel. Tcc ice PXocks 0 Dry Ice ❑ None ❑ Yes ❑No ❑ 3. It'temperature ol'an}ee,ctl�r ��c:ccdcd , was Prajecr Massager Vs,iiliall? PM was Not iTedb+r- ph,5ne c;muilr'fwc-tfa-f W (chcleone)- Y--x No ,l NA d- Is the COmmcrc;io-il uxuricr's packing slip aattac;red to LWS J0FUI? M Y-.L, LJN 5- Wei6pi-ijcT rw; dy-proccd-ure3 (ref iVisheNreceivicel) l•u11;iwL%3," Re Y-t No 6- l�re� a sample ]I)!;listed an die C:OC? yes ❑ iNn 7- Wffm -*3-nplc JD5 listed on all Savnple cotltaiFLVEQ RJ Y�* NO S. Wnscollccti(mdare&.rime listed on Ltt6COC',? +� Yc s L1 No 9, Vas eolk-cton dare & rime l isted on all sample containcxs? d Yt� ❑ No 10, laid all c%antainci' label intiarinaricm (TT), da-, Lim u) ate. w;th the CDC? d Lo E]Nol I 11, WGTC t= to be pertbrmed Hrue:l fin 1he C O C,? 0 Yeea ❑ No 12, ) )id All aamplrs aazive in the proper OnLuiners for cash test arid,or in good. condlLls,u (imbrnken, lids on. ,f Yer Nu 13. Wu-s wlri{uaw wimple v'olumc available" o 14. Wernall .yslmplo� roxiv�cdwitllin1,the holdiogtimcor48hours,mrhiche❑erconies Crst? MAN� 15. Were arty sample s umtrinon mi5su Ss circle orlir) kurnplcs NOt listed m {;{JC:'a ❑'Y-es ❑,f Nu NA 16. to: VUA and R5K-l7i ;ample,-,, wv,; a les present--pea-sjLC (/,"{rr6mm in diamctu) in jLiv ofrhe V0A vial-S! `re5El No NA 17- Wi:= all DKOrYnotalsrnutrient ;alit lrs rei-:eivv d nl as pH Ld� 2? Yeti No NA 18. Wcrc all C�ranide Sam les rcceiVVj at 4 pH = 12 and sW ide samples received Ut a pH > 9'r ❑, Yc4 �Tlo El C*rl 19- IVY -c a app ice N1i.j TKNiic LitLidu?P1WrtLsUb.3 25. L"15IM (< 0-5rng; L} samples free of residual chlorine? ❑ Ye;s ❑ Vey [a 1A0 ', WoTp client remarWreqursts (i.c. mrlue5ted dilittiorl8, MS.,MST) �1c4igmouns, ctc,,.) correctly trancrihed fr{�n #1 to [ OL' iota the conttttent set Liun in Ll'1S'fi ire; aler 21. Was zh� uvW number Jist:.d an the container label? Tf o5, tl=. Sam ple PreservRtion (MusL be e;urrrp1vLLQ for Imy samplc(s) incorrectly preserved ryr with hoadspace. ) Sa,rrple(w) h1'1 - cr cci;eli hrcarre tl} pies: rtiexl Lutti WCfI, a tLStcda cordin ly in Sample receiving. with V4 mL of6wie uric: N2SO4. HNf }3, HC;1, ha(1J 1 u31nG 9R g A llue of prewrvulion NA if more than nhe pr"crvath-c i5 needed, pie lse rktiLc irl Lhc vurm:'Ilts bclow, Saulpi-e(s) * wcrorcccivcdwith bulihles>6 mrrr in rliamwtcvr, Sarrrple;4(} ,4 were l'ecei'red with TRC > 0,5 rrlgr'I., (JI'fr'19 i3 no) and were ljuskxl a"ca:diggly in sample receiving %%-Ah .;Qdium thiosuifate (Ka,S,0) wish Shcaly 11D; N.1,L S R- bawode~ babel: applicd by: T 0 DOC- (r31'_'0 M22 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 18 of 19 PACE ANALYTICAL SERVICES, LLC Samples Receipt Checklist JSRQ (MECOI&C-151 Revlsed:9J29j2020 dery L�dl,lrrr 3f w uing Au1114riLy: Pate ENV - WCOt_ N30e S of 1 amp]e Receipt C.'heckligt (SRC) C1ieuL: C'DN'] M1Lh C'M&TTnspeL:ieLLbyida[C; TUC 031311'2022 Lot r; XC30013.'XC1D02.2 Murans of rs: uipl; El 1'acc ('Jiem4,11'S U FAx L1 Cnhar; Yes ,f No I l_ Were 01lslod • seals PrEMM oaf Chi' C001er7 Yes Nu ,l ETA 2. if custody seals were presem, ware they intvt and unLvoken? aH 91.6p TT3_ 21-052 CJiluri u "Si rip TT}_ 4 _ 1'cstx d L1'�'; -Tf. igingl Lemptratmre urwm rncte rit? l crivcd (C(mi,wtod) tCmpra'attlrc trpon rcccipt ' oSolEd Snap-C rp 113: VA 1.3 ++13 uC 5.:b +5.3 -C 3.9 0.9 `-C NA NA vC _ hod: ❑Zl i'emperattue BImik D1gainst Bottle~; TR 0un ID: TR Gun Cama;Lion }'au;lclr a ac Method of enolant, E Wel. Ire Ej 1re Pnckx ❑ T-)ry Ten ❑ Nrync ❑ 1 cs []NO ❑% NA 3_ Itternpe=re of any arnrkler ehceedod fi.0°C , was Pro-imi Mnnr3g2r N'(1tiFlCd? - -- FDA v;-m Notified by: phorke e email +" lkertirfLwr (Limle on,), i Year NLa NA 4. is the commewial courier's packirkn, slip uUaLlied Lo Lhiy form? -- ,oe' Ycc No S_ Were PM-3per CUSLOdly rrmceslureti (rplinquishcd+'r-�t<ciV.�d) falLawed'x Yec No 6_ Wern sample MT L1isrnil fn the ( ? d Yes ❑ No 7_ Wern sample Ms 1isrEd i n all samtptc eontainm? 21 Ycsl0 8. Ww cvllcction daft cc tone listed on file C:{]{? Ves Mo 9. Was unllcetion date 3 time listed an all sarnpIa containers;? d n+ , ] D. Laid. all conm;ner label information (TT3, ;laie, 1innr) agrcc with th,. COC ) Ye Flo 11. V4'ere tesrs ro be performed listed 17rk Lhe {�f}C? YES t —� LI NLP l2, Did till Eauip]C3 arrivc in the prOppr Containers for EW11 UYU and;Dt i-3 4[1ix3 Ulnilil]'M funhrokrn, lids nn, etr:,)? d Yes LNP 13. Vdas adequate sample uulunee aaailablt? V 14. Were all saarlples> reueivi-d wilhirl 4a Lhc ,-k timG or 4� hoan, whichrver comes first? Fe ` 15. Were any samlrles corkminL mid; i-n as' (CirclU one) samples Not listed on CCOC" ❑ Y Nu N' lb. Lor V0A and RSK-l?5 sarnpIPc, ru re huhhles, rarcwnnL?"pre-si r" (112'm 6-am in diameter) n1 any ofrhe VO-N vials? 7 Yes Ll her _EjN LJNA I?. Were all DRf lfinetal'`nufrirnt sampIcs rweived w a pH of < 2? ❑, Yes c, 0 NA.1 I R. Wcrr ail q�,rmlidc samples received at a pi1 -- 12 and �.ulFide Nurnplm rx L;jvQd at apH = 9 ❑Yes Olio QNA 19. l�rere all Kr�;licahlc ;: 1K[�+cy'an er'p ono +b25_[+G{18.3 {�U.Srn�+L) wEunplrs 1-rwoF rosidua] Chlorine'? ❑ Y ' No ❑NA 20. Wtrc client re marlasrrequests(i_e_ requesteddil,itions, 1145;MSD dcsilations, etc.__) C01TIeck uanacribed from the C',fi(. inllr the coalmcnt sccfion in LLMS" Y ! No 2 L. Wil% l}re q uoic nurnbcr Jtslcd on the cc+rltaincz Jabcl'? if yes, Quote >r Sample Preserratiau {Nl st be compItLed- fro-r any yarn pl(s) ins i;trd) prescrvod or with headspaoe_) Sarnple(s) NA—vw'ere mceived imxiji, dly j1mj -trixl atad wau asliastcdaccordin¢I}� irk crimple t=:6 ving w t1h l � mL, of ah'cle oile: H2.SO4, ] 1NO3, FTCl.. NLL(-)H w 9 ing SR 4 N Timu of prus,;:rvntion NA 1f moo. tt an one p esenmil'e i s needed, n cytc % the conummits below. Sample(s) wcrcrcccivzdwith bubbles>6 mm in diarne:wr. Sankples(s) TM^ were received with TRC :> 0.S mg,T, (Tf #'19 i3 rto) and were adju.slcrl uoL ordirgly in Eampl:.lxa ei?v>g with sodium thiosulfate LNa2S,03) with SUHly U); N`ry` 4Rbarcodelabels appliedhy; 1C� -- Dam. r.0r'I U2 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 19 of 19 (� aceAna/ytical W LELAP CERTIFICATE NUMBER: 01955 DOD-ELAP ACCREDITATION NUMBER: 74960 ANALYTICAL RESULTS •:I Pace Analytical Gulf Coast 7979 Innovation Park Dr. Baton Rouge, LA 70820 (225) 769-4900 Report Date 04/13/2022 Report Y 222040226 �1��i �1��i �1��i �1��i �1��i �1��i �1��i �1��i �1��i III Project North Wake Unlined XC30013 Samples Collected 3/30/22 Deliver To Cathy Dover Pace 106 Vantage Point Drive West Columbia, SC 29172 (803)791-9700 PJLA 1XMINg DOD ELAF Additional Recipients NONE k7025 JI Pace Gulf Coast Report#: 222040226 Page 1 of 15 Report#: 222040226 ace k k+ytUh Project ID: North Wake Unlined XC30013 Report Date: 04/13/2022 Laboratory Endorsement Sample analysis was performed in accordance with approved methodologies provided by the Environmental Protection Agency or other recognized agencies. The samples and their corresponding extracts will be maintained for a period of 30 days unless otherwise arranged. Following this retention period the samples will be disposed in accordance with Pace Gulf Coast's Standard Operating Procedures. Common Abbreviations that may be Utilized in this Report ND Indicates the result was Not Detected at the specified reporting limit NO Indicates the sample did not ignite when preliminary test performed for EPA Method 1030 DO Indicates the result was Diluted Out MI Indicates the result was subject to Matrix Interference TNTC Indicates the result was Too Numerous To Count SUBC Indicates the analysis was Sub -Contracted FLD Indicates the analysis was performed in the Field DL Detection Limit LOD Limit of Detection LOQ Limit of Quantitation RE Re -analysis CF HPLC or GC Confirmation 00:01 Reported as a time equivalent to 12:00 AM Reporting Flags that may be Utilized in this Report J or I Indicates the result is between the MDL and LOQ J DOD flag on analyte in the parent sample for MS/MSD outside acceptance criteria U Indicates the compound was analyzed for but not detected B or V Indicates the analyte was detected in the associated Method Blank Q Indicates a non -compliant QC Result (See Q Flag Application Report) " Indicates a non -compliant or not applicable QC recovery or RPD — see narrative E Organics - The result is estimated because it exceeded the instrument calibration range E Metals - % diference for the serial dilution is > 10% L Reporting Limits adjusted to meet risk -based limit. P RPD between primary and confirmation result is greater than 40 DL Diluted analysis — when appended to Client Sample ID Sample receipt at Pace Gulf Coast is documented through the attached chain of custody. In accordance with NELAC, this report shall be reproduced only in full and with the written permission of Pace Gulf Coast. The results contained within this report relate only to the samples reported. The documented results are presented within this report. This report pertains only to the samples listed in the Report Sample Summary and should be retained as a permanent record thereof. The results contained within this report are intended for the use of the client. Any unauthorized use of the information contained in this report is prohibited. I certify that this data package is in compliance with The NELAC Institute (TNI) Standard 2009 and terms and conditions of the contract and Statement of Work both technically and for completeness, for other than the conditions in the case narrative. Release of the data contained in this hardcopy data package and in the computer readable data submitted has been authorized by the Quality Assurance Manager or his/her designee, as verified by the following signature. Estimated uncertainty of measurement is available upon request. This report is in compliance with the DOD QSM as specified in the contract if applicable. Authorized Signature Pace Gulf Coast Report 222040226 Pace Gulf Coast Report#: 222040226 Page 2 of 15 Report#: 222040226 aceAr�alYl�+l Project ID: North Wake Unlined XC30013 Report Date: 04/13/2022 Certifications Certification Certification Number DOD ELAP 74960 Alabama 01955 Arkansas 88-0655 Colorado 01955 Delaware 01955 Florida E87854 Georgia 01955 Hawaii 01955 Idaho 01955 Illinois 200048 Indiana 01955 Kansas E-10354 Kentucky 95 Louisiana 01955 Maryland 01955 Massachusetts 01955 Michigan 01955 Mississippi 01955 Missouri 01955 Montana N/A Nebraska 01955 New Mexico 01955 North Carolina 618 North Dakota R-195 Oklahoma 9403 South Carolina 73006001 South Dakota 01955 Tennessee 01955 Texas T104704178 Vermont 01955 Virginia 460215 Washington C929 USDA Soil Permit P330-16-00234 Pace Gulf Coast Report#: 222040226 Page 3 of 15 Report#: 222040226 ace k k+ytUh Project ID: North Wake Unlined XC30013 Report Date: 04/13/2022 Case Narrative Client: Pace Analytical Services South Carolina Report: 222040226 Pace Analytical Gulf Coast received and analyzed the sample(s) listed on the Report Sample Summary page of this report. Receipt of the sample(s) is documented by the attached chain of custody. This applies only to the sample(s) listed in this report. No sample integrity or quality control exceptions were identified unless noted below. No anomalies were found for the analyzed sample(s). Pace Gulf Coast Report#: 222040226 Page 4 of 15 ace k k+ytUh Report#: 222040226 Project ID: North Wake Unlined XC30013 Report Date: 04/13/2022 Sample Summary Lab ID Client ID Matrix Collect Date Receive Date 22204022601 MW-8 Water 3/30/22 08:30 4/01/22 09:30 22204022602 MW-5R Water 3/30/22 09:05 4/01/22 09:30 22204022603 MW-34 Water 3/30/22 09:40 4/01/22 09:30 22204022604 MW-34d Water 3/30/22 10:00 4/01/22 09:30 22204022605 MW-9 Water 3/30/22 10:30 4/01/22 09:30 22204022606 MW-36 Water 3/30/22 11:00 4/01/22 09:30 22204022607 MW-6 Water 3/30/22 11:40 4/01/22 09:30 22204022608 MW-10 Water 3/30/22 12:15 4/01/22 09:30 22204022609 MW-11 Water 3/30/22 15:10 4/01/22 09:30 22204022610 MW-8 H2 Bubble Strip 3/30/22 08:30 4/01/22 09:30 22204022611 MW-5R H2 Bubble Strip 3/30/22 09:05 4/01/22 09:30 22204022612 MW-6 H2 Bubble Strip 3/30/22 11:40 4/01/22 09:30 Pace Gulf Coast Report#: 222040226 Page 5 of 15 k Report#: 222040226 ace k+ytUh Project ID: North Wake Unlined XC30013 Report Date: 04/13/2022 Detect Summary Results and Detection Limits are adjusted for dilution and moisture when applicable AM23G Lab ID Client ID Parameter Units Result Dil. %Moist 22204022601 MW-8 Acetic Acid mg/L 0.21 J 1 NA 22204022601 MW-8 Formic Acid mg/L 4.2 1 NA 22204022601 MW-8 Lactic Acid mg/L 0.42J 1 NA 22204022602 MW-5R Acetic Acid mg/L 0.46J 1 NA 22204022602 MW-5R Formic Acid mg/L 1.0 1 NA 22204022602 MW-5R Hexanoic Acid mg/L 0.062J 1 NA 22204022602 MW-5R Lactic Acid mg/L 0.38J 1 NA 22204022603 MW-34 Acetic Acid mg/L 0.25J 1 NA 22204022603 MW-34 Formic Acid mg/L 4.5 1 NA 22204022603 MW-34 Hexanoic Acid mg/L 0.21J 1 NA 22204022603 MW-34 Lactic Acid mg/L 0.33J 1 NA 22204022604 MW-34d Formic Acid mg/L 0.72 1 NA 22204022604 MW-34d Lactic Acid mg/L 0.054J 1 NA 22204022605 MW-9 Formic Acid mg/L 0.57 1 NA 22204022605 MW-9 Lactic Acid mg/L 0.059J 1 NA 22204022606 MW-36 Formic Acid mg/L 1.0 1 NA 22204022607 MW-6 Formic Acid mg/L 13 10 NA 22204022607 MW-6 Hexanoic Acid mg/L 0.61J 10 NA 22204022608 MW-10 Formic Acid mg/L 0.79 1 NA 22204022608 MW-10 Lactic Acid mg/L 0.063J 1 NA 22204022609 MW-11 Formic Acid mg/L 0.92 1 NA AM20GAX Lab ID Client ID Parameter Units Result Dil. %Moist 22204022610 MW-8 H2 Hydrogen nM 0.92J 1 NA 22204022611 MW-5R H2 Hydrogen nM 1.4J 1 NA 22204022612 MW-6 H2 Hydrogen nM 0.75J 1 NA Pace Gulf Coast Report#: 222040226 Page 6 of 15 Report#: 222040226 Project ID: North Wake Unlined XC30013 Report Date: 04/13/2022 Sample Results MW-8 Collect Date 03/30/2022 08:30 Lab ID 22204022601 Receive Date 04/01/2022 09:30 Matrix Water 3G Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/04/2217:21 737547 SLL2 NA CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.21J 0.12 0.50 mg/L 107-92-6 Butyric Acid 0.058U 0.058 0.50 mg/L 64-18-6 Formic Acid 4.2 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.058U 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.056U 0.056 0.50 mg/L 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.42J 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.056U 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.053U 0.053 0.50 mg/L 127-17-3 Pyruvic Acid 0.060U 0.060 0.50 mg/L MW-5R Collect Date 03/30/2022 09:05 Lab ID 22204022602 Receive Date 04/01/2022 09:30 Matrix Water 3G Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/04/2217:43 737547 SLL2 NA CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.46J 0.12 0.50 mg/L 107-92-6 Butyric Acid 0.058U 0.058 0.50 mg/L 64-18-6 Formic Acid 1.0 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.062J 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.056U 0.056 0.50 mg/L 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.38J 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.056U 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.053U 0.053 0.50 mg/L 127-17-3 Pyruvic Acid 0.060U 0.060 0.50 mg/L Collect Date 03/30/2022 09:40 Lab ID 22204022603 MW�34 Receive Date 04/01/2022 09:30 Matrix Water 3G Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/04/2218:04 737547 SLL2 NA CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.25J 0.12 0.50 mg/L 107-92-6 Butyric Acid 0.058U 0.058 0.50 mg/L 64-18-6 Formic Acid 4.5 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.21J 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.056U 0.056 0.50 mg/L Pace Gulf Coast Report#: 222040226 Page 7 of 15 ..-] Report#: 222040226 Project ID: North Wake Unlined XC30013 Report Date: 04/13/2022 Sample Results MW-34 Collect Date 03/30/2022 09:40 Lab ID 22204022603 Receive Date 04/01/2022 09:30 Matrix Water 3G (Continued) Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/04/2218:04 737547 SLL2 NA CAS# Parameter Result DL LOQ Units 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.33J 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.056U 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.053U 0.053 0.50 mg/L 127-17-3 Pyruvic Acid 0.060U 0.060 0.50 mg/L MW-34d Collect Date 03/30/2022 10:00 Lab ID 22204022604 Receive Date 04/01/2022 09:30 Matrix Water 3G Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/04/2219:09 737547 SLL2 NA CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.12U 0.12 0.50 mg/L 107-92-6 Butyric Acid 0.058U 0.058 0.50 mg/L 64-18-6 Formic Acid 0.72 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.058U 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.056U 0.056 0.50 mg/L 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.054J 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.056U 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.053U 0.053 0.50 mg/L 127-17-3 Pyruvic Acid 0.060U 0.060 0.50 mg/L Collect Date 03/30/2022 10:30 Lab ID 22204022605 MW-9 Receive Date 04/01/2022 09:30 Matrix Water 3G Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/04/2219:31 737547 SLL2 NA CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.12U 0.12 0.50 mg/L 107-92-6 Butyric Acid 0.058U 0.058 0.50 mg/L 64-18-6 Formic Acid 0.57 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.058U 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.056U 0.056 0.50 mg/L 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.059J 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.056U 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.053U 0.053 0.50 mg/L Pace Gulf Coast Report#: 222040226 Page 8 of 15 Report#: 222040226 Project ID: North Wake Unlined XC30013 Report Date: 04/13/2022 Sample Results MW-9 Collect Date 03/30/2022 10:30 Lab ID 22204022605 Receive Date 04/01/2022 09:30 Matrix Water AM23G (Continued) Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/04/2219:31 737547 SLL2 NA CAS# Parameter Result DL LOQ Units 127-17-3 Pyruvic Acid 0.060U 0.060 0.50 mg/L MW-36 Collect Date 03/30/2022 11:00 Lab ID 22204022606 Receive Date 04/01/2022 09:30 Matrix Water G Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/04/2219:52 737547 SLL2 NA CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.12U 0.12 0.50 mg/L 107-92-6 Butyric Acid 0.058U 0.058 0.50 mg/L 64-18-6 Formic Acid 1.0 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.058U 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.056U 0.056 0.50 mg/L 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.053U 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.056U 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.053U 0.053 0.50 mg/L 127-17-3 Pyruvic Acid 0.060U 0.060 0.50 mg/L Collect Date 03/30/2022 11:40 Lab ID 22204022607 MW�6 Receive Date 04/01/2022 09:30 Matrix Water AM23G "Results And limits are adjusted for dilution. Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 10 04/04/22 20:14 737547 SLL2 NA CAS# Parameter 64-19-7 Acetic Acid 107-92-6 Butyric Acid 64-18-6 Formic Acid 142-62-1 Hexanoic Acid 646-07-1 i-Hexanoic Acid 503-74-2 i-Pentanoic Acid 50-21-5 Lactic Acid 109-52-4 Pentanoic Acid 79-09-4 Propionic Acid 127-17-3 Pyruvic Acid Result DL LOQ Units 1.2U 1.2 5.0 mg/L 0.58U 0.58 5.0 mg/L 13 0.55 5.0 mg/L 0.61J 0.58 5.0 mg/L 0.56U 0.56 5.0 mg/L 0.61 U 0.61 5.0 mg/L 0.53U 0.53 5.0 mg/L 0.56U 0.56 5.0 mg/L 0.53U 0.53 5.0 mg/L 0.60U 0.60 5.0 mg/L Pace Gulf Coast Report#: 222040226 Page 9 of 15 Report#: 222040226 Project ID: North Wake Unlined XC30013 Report Date: 04/13/2022 Sample Results MW-1 O Collect Date 03/30/2022 12:15 Lab ID 22204022608 Receive Date 04/01/2022 09:30 Matrix Water G Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/04/22 20:35 737547 SLL2 NA CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.12U 0.12 0.50 mg/L 107-92-6 Butyric Acid 0.058U 0.058 0.50 mg/L 64-18-6 Formic Acid 0.79 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.058U 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.056U 0.056 0.50 mg/L 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.063J 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.056U 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.053U 0.053 0.50 mg/L 127-17-3 Pyruvic Acid 0.060U 0.060 0.50 mg/L MW-1 1 Collect Date 03/30/2022 15:10 Lab ID 22204022609 Receive Date 04/01/2022 09:30 Matrix Water G Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/04/22 20:57 737547 SLL2 NA CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.12U 0.12 0.50 mg/L 107-92-6 Butyric Acid 0.058U 0.058 0.50 mg/L 64-18-6 Formic Acid 0.92 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.058U 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.056U 0.056 0.50 mg/L 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.053U 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.056U 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.053U 0.053 0.50 mg/L 127-17-3 Pyruvic Acid 0.060U 0.060 0.50 mg/L Q Collect Date 03/30/2022 08:30 Lab ID 22204022610 MW�v HZ Receive Date 04/01/2022 09:30 Matrix Bubble Strip GAX Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/13/2215:17 738409 AWE NA CAS# Parameter 1333-74-0 Hydrogen Result DL LOQ Units 0.92J 0.49 1.9 nM Pace Gulf Coast Report#: 222040226 Page 10 of 15 ..-] Report#: 222040226 Project ID: North Wake Unlined XC30013 Report Date: 04/13/2022 Sample Results MW-5R H2 Collect Date 03/30/2022 09:05 Lab ID 22204022611 Receive Date 04/01/2022 09:30 Matrix Bubble Strip AM20GAX Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/13/2215:35 738409 AWE NA CAS# Parameter Result DL LOQ Units 1333-74-0 Hydrogen 1.4J 0.49 1.9 nM MW-6 H2 Collect Date 03/30/2022 11:40 Lab ID 22204022612 Receive Date 04/01/2022 09:30 Matrix Bubble Strip AM20GAX Prep Date Prep Batch Prep Method Dilution Run Date Run Batch Analyst %Moisture NA NA NA 1 04/13/2215:47 738409 AWE NA CAS# Parameter 1333-74-0 Hydrogen Result DL LOQ Units 0.75J 0.49 1.9 nM Pace Gulf Coast Report#: 222040226 Page 11 of 15 Report#: 222040226 Project ID: North Wake Unlined XC30013 Report Date: 04/13/2022 General Chemistry QC Summary Analytical Batch Client ID MB737547 LCS737547 LCSD737547 737547 Lab ID 2327137 2327138 2327139 Sample Type MB LCS LCSD Prep Date NA NA NA Analysis Date 04/04/22 14:29 04/04/22 14:07 04/04/22 18:26 Matrix Water Water Water AM23G Units mg/L Spike Result %R Control Spike Result %R RPD RPD Result DL Added Limits%R Added Limit Acetic Acid 64-19-7 0.12U 0.12 2.0 2.0 101 70 - 130 2.0 2.0 98 3 20 Butyric Acid 107-92-6 0.058U 0.058 2.0 1.9 95 70 - 130 2.0 2.0 98 3 20 Formic Acid 64-18-6 0.055U 0.055 2.0 2.0 99 70 - 130 2.0 2.0 99 1 20 Hexanoic Acid 142-62-1 0.058U 0.058 2.0 1.8 91 70 - 130 2.0 2.1 107 17 20 i-Hexanoic Acid 646-07-1 0.056U 0.056 2.0 2.3 117 70 - 130 2.0 2.6 130 10 20 i-Pentanoic Acid 503-74-2 0.061 U 0.061 2.0 2.2 108 70 - 130 2.0 2.2 108 0 20 Lactic Acid 50-21-5 0.053U 0.053 2.0 2.4 122 70 - 130 2.0 2.6 129 5 20 Pentanoic Acid 109-52-4 0.056U 0.056 2.0 2.1 106 70 - 130 2.0 2.1 106 0 20 Propionic Acid 79-09-4 0.053U 0.053 2.0 2.0 98 70 - 130 2.0 2.0 100 2 20 Pyruvic Acid 127-17-3 0.060U 0.060 2.0 1.8 91 70 - 130 2.0 1.8 92 0 20 Pace Gulf Coast Report#: 222040226 Page 12 of 15 Report#: 222040226 Project ID: North Wake Unlined XC30013 Report Date: 04/13/2022 General Chromatography QC Summary Analytical Batch Client ID MB738409 LCS738409 LCSD738409 738409 Lab ID 2332055 2332056 2332057 Sample Type MB LCS LCSD Prep Date NA NA NA Analysis Date 04/13/22 15:05 04/13/22 14:41 04/13/22 14:53 Matrix Bubble Strip Bubble Strip Bubble Strip AM20GAX Units nM Spike Result %R Control Spike Result %R RPD RPD Result DL Added Limits%R Added Limit Hydrogen 1333-74-0 0.49U 1 0.491 121 9.41 79 1 70 - 130 1 121 9.5180 1 1 1 20 Pace Gulf Coast Report#: 222040226 Page 13 of 15 aceAnalyticai " Chain of Custody Record r Client ID- Shealy Enwr -Pace Analy" Services South Carolina I Pace Analytical Services, L>wC. 3DG: 222040226 106 Vantage Point Drive PM: RWe West Columbia, South Carolina 29172 Telephone No. (803) 791-9700 Fax No. (803) 791-9111 unurel nnrAlahc rnm Cflent Report to Contact Telephone No.I E-mail quote No. Pace Analytical Services -West Columbia Catherine S. Dover cathy.dover@pacelabs.com Address Sampler's Signature Analysis (Attach list if more space is needed) Page 106 Vantage Point Drive x 1 01 1 City Slate Zip Code Lot # Bar Code West Columbia SC 29172 Printed Name (lab use only) Project Name North Wake Unlined Landfill Project Number P o- No- Matrix No of Containers by � Presentative Type d Sample ID 1 Description Collection Collection Time $ a c c 0 m z Z Y Y Remarks 1 CooEer 1-D, lConWnem rore of sample may be c Ibl ed on one rina] ❑ate{s) (military) 11 a 0 U r 2:0 o m MW-8 3/30/2022 0830 G X 1 2 X X XC30013-020 MW-5R 3/30/2022 D905 G X 1 2 X X XC30013-021 MW-34 3/30/2022 0940 G X 2 X XC30013-022 MW-34d 3/30/2022 100o G X 2 X XC30013-023 MW-9 3/30/2022 1030 G X 2 X XC30013-024 MW-36 3/30/2022 1100 G X 2 X XC30013-025 MW-6 3/30/2022 1140 G X 1 2 X X XC30013-026 MW-10 3/30/2022 1215 G X 2 X XC30013-027 MW-11 3/30/2022 1510 G X 2 X XC30013-028 Level 2 with NCDEQ EQUIS and excel Turn Around Time Required (Prior lab approval required for expedited TAT) Sample Disposal Possible Hazard Identification (List any known hazards in the remarks) QC Requirements ❑Standard ❑ Rush Please ecff 10 BUSINESS DAYS 5}7 y) Return to Client DIs osal b Lab ❑ ❑ p y ❑ rJun-Hazardous ❑ Flemma6le ❑ Skrn indent ❑ SQS provided ❑ Vnknown batch QC or LQSILCSD 1. Relinquished by Dale Tlme 1. Received by Date Time 2. Relinquished by �^� ❑ Time - 2, fie ived by Date Time z � C-'- q ,- p 3. Relinquished by D e Time 3. Received by Date Time 4. Relinquished by Date Tim 4. Laboratory Received by Date Time Note: All samples are retained for four weeks from LAB USE ONLY Receipt Temp. Temp. Blank receipt unless other arrangements are made Received on Ice (Cheek) ❑ Y ❑ N ❑ Ice Pack ° C ❑ Y 1 ❑N 766/ Pace Gulf Coast Report#: 222040226 Page 14 of 15 /.5navivfica' SAMPLE RECEIVING CHECKLIST IIIIII0 IIIII SAMPLE DELIVERY GROUP 222040226 CHECKLIST YES NO Client PM RWe Transport Method Samples received with proper thermal preservation? *❑ ❑ Shealy Envir - Pace Analytical FEDDC Services South Carolina Radioactivity is <1600 cpm? If no, record cpm value in notes section. COC relinquished and complete (including samplelDs, collect times, and sampler)? *❑ *❑ ❑ ❑ Profile Number Received By 284727 Henderson, Jacob R All containers received in good condition and within hold time? All sample labels and containers received match the chain of custody? 0 0 ❑ ❑ Line Item(s) Receive Date(s) 1 - LL V FA 04/01/22 2- Hydrogen Preservative added to any containers? ❑ *❑ If received, was headspace for VOC water containers < 6mm? *❑ ❑ Samples collected in containers provided by Pace Gulf Coast? 0 ❑ COOLERS DISCREPANCIES LAB PRESERVATIONS Airbill Thermometer ID: E34 Temp °C None None 1663 8466 7661 5.3 NOTES Revision 1.6 Page 1 of 1 Pace Gulf Coast Report#: 222040226 Page 15 of 15