HomeMy WebLinkAbout6301_MooreCounty_MSWLF_CDLF_June2022LFG_FID1682002_20220610ENR USE ONLY—.
j ❑Paper Report ❑Electronic Data - Email CD data loaded: Yes / No Doc/Event #:
c DEIVR I I Environmental Monitoring
Division of Waste Management - Solid Waste Reporting Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
• Prepare one form for each individually monitored unit.
• Please type or print legibly.
Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification
must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing
condition, etc.).
• Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits.
• Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the
facility (NCAC 13B .1629 (4)(a)(i).
Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste
Section, 1646 Mail Service Center, Raleigh, NC 27699-1646.
Solid Waste Monitoring Data Submittal Information
Name of entity submitting data (laboratory, consultant, facility owner):
5&ME, Inc. (on behalf of Moore County)
Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address:
Name: Edmund Q.B. Henriques Phone: 336-288-7180
E-mail: ehenriques@smeinc.com
NC Landfill Rule: Actual sampling dates (e.g.,
Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006)
June 7, 2022
Moore County Landfill 456 Turning Leaf Way, Aberdeen, NC 63-01 .0500
Environmental Status: (Check all that apply)
Initial/Background Monitoring ❑x Detection Monitoring Assessment Monitoring Corrective Action
of data submitted: (Check all that apply)
Groundwater monitoring data from monitoring wells x❑
Groundwater monitoring data from private water supply wells ❑
Leachate monitoring data El
water monitoring data
Methane gas monitoring data
Corrective action data (specify)
Other(specify)
Notification attached?
e No. No groundwater or surface water standards were exceeded.
Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water
monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and
preliminary analysis of the cause and significance of any concentration.
�x Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample
values and explosive methane gas limits.
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct.
Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas
levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. 1 am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
Edmund Q.B. Henriques, PG Senior Geologist, S&ME Inc. 336-312-3330
Facility Representative Name (Print) Title (Area Code) Telephone Number
6/10/2022
re Date
8646 W. Market Street, Suite 105, Greensboro NC 27409
Facility Representative Address
F-0176
NC PE Firm License Number (if applicable effective May 1, 2009)
Revised 6/2009
Affix NC Licens@04Professional Geologist Seal
v �
.41
0Cn
1216
Z
'L `ffi
Q. B
9g�+�ceae: a no�e�,�dap�o.
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Moore County Landfill Permit Number: 63-01
Sampling Date: June 7, 2022 NC Landfill Rule (.0500 or.1600): 0.0500
Sample Collector Name & Position: Ed Henriques / Senior Geologist, SWE, Inc.
Gas Meter Type & Serial Number: GEM 5000 / SN G506450
Field Calibration Date & Time: 6/6/2022
Gas Meter Calibration Date: 8/16/2021
Field Calibration Gas Type (15115 or 35/50): 1 5/15 Field Calibration Gas Canister Expiration Date: 01 /2 02 5
Gas Meter Pump Rate: 676 cc/min
Ambient Air Temperature: 85 Barometric Pressure (in. or mm Hg): 29.10" Weather Conditions: Partly Sunny
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location may or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See
individual permit conditions andlor Facility LFG monitoring plan.
Location or
LFG Well ID
S ample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
% LEL
Stabilized
% LEL
% CH4
� volume �
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
GP-9
60
1211
120
0
0
0.0
19.5
11.2
0
Property Boundary Monitoring Point
G P 10R
60
1221
120
0
0
0.0
18.2
2.2
0
Property Boundary Monitoring Point
GP-1 1
60
1 226
120
0
0
0.0
11.6
7.2
0
Property Boundary Monitoring Point
GP-1 2
60
1 251
120
0
0
0.0
20.6
0.6
0
Property Boundary Monitoring Point
GP-1 3R
60
1306
120
0
0
0.0
19.4
11.8
0
Property Boundary Monitoring Point
G P-14 R
60
1314
120
0
0
0.0
19.2
1.5
0
Property Boundary Monitoring Point
GP-1 5R
60
1321
120
0
0
0.0
18.5
2.9
0
Property Boundary Monitoring Point
GP-16
60
1328
120
0
0
0.0
11.6
1 0. 1
0
Property Boundary Monitoring Point
GP-17
60
1336
120
0
0
0.0
9.0
12.5
0
Property Boundary Monitoring Point
GP-18
60
1408
180
> 100
> 100
42.4
0.7
30.8
0
Property Boundary Monitoring Point
GP-19
60
1351
120
0
0
0.0
16.8
4.7
0
Property Boundary Monitoring Point
NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility.
ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or certification including the possibility of a fine and imprisonment.
Senior Geologist / SWE, Inc.
SIGNATURE TITLE
Revised -March 6, 2017
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Moore County Landfill Permit Number: 63-01
Sampling Date: June 7, 2022 NC Landfill Rule (.0500 or.1600): 0.0500
Sample Collector Name & Position: Ed Henriques / Senior Geologist, S&ME, Inc.
Gas Meter Type & Serial Number: GEM 5000 / SN G506450
Field Calibration Date & Time: 6/6/2022
Gas Meter Calibration Date: 8/16/2021
Field Calibration Gas Type (15115 or 35/50): 1 5/15 Field Calibration Gas Canister Expiration Date: 01 /2025
Gas Meter Pump Rate: 676 cc/min
Ambient Air Temperature: 85 Barometric Pressure (in. or min Hg): 29.10" Weather Conditions: Partly Sunny
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location may or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See
individual permit conditions and/or Facility LFG monitoring plan.
Location or
LFG Well ID
S ample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
% LEL
Stabilized
% LEL
% CH4
(volume)
�
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
M W-6
60
1345
120
> 100
94
4.7
15.8
14.7
0
not a compliance point
GV-33
60
1415
120
> 100
> 100
49.1
0.1
37.7
0
Passive vent, not a compliance point
GV-34
60
1421
120
> 1 00
> 1 00
50.7
0.2
37.6
0
Passive vent, not a compliance point
Scale House
60
1204
120
0
0
0.0
20.8
0.1
0
on -site structure
Maintenance Shop
60
1242
120
0
0
0.0
20.5
0.1
0
on -site structure
Transfer Station
60
1234
120
0
0
0.0
20.5
0.1
0
on -site structure
Blake Residence
60
1506
120
0
0
0.0
21.0
0.1
0
off -site structure
G P -2 0
60
1358
120
> 10 0
> 10 0
30.5
0.1
29.2
0
temporary monitoring point, west of cut-off trench
G P-21
60
1431
120
> 100
> 100
56.5
0.1
39.3
0
temporary monitoring point, east of cut-off trench
NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility.
ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or certification includin the possibility of a fine and imprisonment.
Senior Geologist / SWE, Inc.
SIGNATURE V TITLE
Revised -March 6, 2017
Table 1
Summary of 2020 & 2022 Methane Gas Readings
Moore County Landfill (Permit 63-01)
Moore County, North Carolina
S&ME Project No. 4358-20-043A
Location Scale- house
g Point Type •
7
02/17/20 0.0%
Maintena
Shop
•
0.0%
Station
•
0.0%
Blake
Crawlspace
•V,f,
0.0%
GP-9
0.0%
r
footn tel.
18.7%
WUFMl!
not installed
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
See
footnote#2
0.0%
0.0%
0.0%
0.0%
See
footnote#1
11.9%
Al
28.1%
not installed
r
See
footnote#4
not installed
NEGEMEM
See
footnote#4
not installed
04/07/20
0.0%
0.0%
0.0%
0.0%
0.0%
32.2%
not installed
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.4%
23.6%
59.9%
not installed
not installed
not installed
09/15/20
0.1%
0.0%
0.0%
0.0%
0.1%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
0.0%
22.5%
0.0%
not installed
not installed
12/14/20
0.0%
0.0%
0.0%
0.1%
0.1%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.5%
9.6%
61.3%
0.0%
not installed
not installed
02/24/21
0.0%
0.0%
0.0%
NM
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.4%
28.7%
67.9%
0.0%
not installed
not installed
04/12/21
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.2%
2.0%
21.8 %
0.0%
not installed
not installed
09/29/21
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.0%
19.5%
57.5%
0.0%
not installed
not installed
12/17/21
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
13.8%
27.8%
0.0%
10.1%
57.0%
03/25/22
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
29.1%
54.7%
0.0%
28.1%
56.4%
06/06/22
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
4.7%
42.4%
0.0%
30.5%
56.5%
Notes:
Monitoring Point Types: PB = Property Boundary, ONSS = On Site Structure, OFFSS = Off -site Structure
Footnote#1 = MW-6 was replace by GP-19 as the property boundary compliance point. MW-6 is approximately 150 feet inside the property boundary and not a compliance point.
Footnote#2 = GP-10 was replaced by GP-10R, GP-13 replaced by GP-13R, GP-14 replaced by GP-14R, GP-15 replaced by GP-15R
Footnote#3 = Groundwater monitoring well MW-15 converted to gas monitoring point now identified as GP-18, which is a property boundary compliance point.
Footnote#4 = Gas monitoring points installed for a cancelled active gas extraction pilot test. A new passive venting pilot test has been proposed.
all measurements recorded in percent methane by volume
Lower explosive limit of methane gas: 5%
Upper explosive limit of methane gas: 15%
Data recorded prior to 9/15/20 obtained by Golder
not installed = Well not installed at the time of monitoring
Yellow highlight cells and values in bold print indicate methane percent by volume greater than or equal to 5% at property boundary monitoring point
Orange highlight cells and values in bold print indicate methane percent by volume greater than or equal to 1.25% inside structures.
TAENV\Projects\2020W5&20-A -- County Routine 1.aWQMonitoring\Phase 01-QuarteriyMMM1ane Monitoring 2021-2022\-R-mgs-1I,-C- IN-RESfi 1. 6/10/2022
CERTIFICATION 11C � o�
OF CALIBRATION
,��-'nM
No. 66916
Date Of Calibration: 16-Aug-2021 Certificate Number: G506450_10/42343
Issued by: QED Environmental Systems Inc.
Customer: ENVIRO EQUIPMENT INC
11180 DOWNS RD PINEVILLE, NC 28134
Description:
Landtec Gas Analyzer
Model:
GEM5000
Serial Number:
G506450
Accredited Results:
Methane WHIM
Certified Gas %
Instrument Reading %
Uncertain %
5.0
15.0
50.0
4.9
15.0
49.0
0.42
0.66
1.03
Carbon Dioxide CO2
Certified Gas %
Instrument Reading %
Uncertain
5.0
15.0
50.0
4.9
14.9
50.5
0.43
0.71
1.19
O en 02
Certified Gas N
Instrument Reading %
Uncertain %
20.5
20.6
0.25
Gas cylinders are traceable and details can be provided if
requested.
CH4, CO2 readings recorded at: 31.8 "C/89.2 °F Barometric Pressure: 0985"Hg/29.08 "Hg
02 readings recorded at: 22.1 `C/71.7 -F
Method of Test : The analyzer is calibrated in a temperature controlled chamber using a series of reference
gases, in compliance with procedure ISP17.
The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2,
providing a level of confidence of approximately 95%. The uncertainty evaluation has been carried out in accordance
with NIST requirements.
The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System of
Units (9). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory.
Page Iof21 LPOISLNA IST-lA
Cahbrvtiov IoSUYK: 112 iGC IvsmK: 112
www.qedenv.com (800) 624-2026 info@qedenv.com
QED Environmental Systems Inc.,. 2355 Bishop Circie West, Dexter, MI 48130
M 7
CERTIFICATION
OF CALIBRATION �'�- IQE
No. 66916
Date Of Calibration: 16-Aug-2021 Certificate Number: G506450_10/42343
Issued by: QED Environmental Systems Inc.
Non Accredited results:
Pressure Transducers inches of water column
Transducer Certified (Low) Reading (Low) Certified (High) Reading (High) Accuracy
Static
0"
0"
40"
1 40.09"
1 2.0"
Differential
0"
0"
4"
1 4.06"
1 0.7"
Barometer mbar
Reference
Instrument Reading
0985 mbar 29.08 "Hg
0985 mbar 29.08 "H
As received gas check readings:
Methane CH4
Certified Gas %
Instrument Reading %
5.0
4.8
15.0
14.6
50.0
48.6
Carbon Dioxide (CO2)
Certified Gas ".6 Instrument Reading%
5.0 5.3
15.0 15.1
50.0 46.4
O en 02
Certified Gas %
Instrument Reading %
20.5
20.5
As received Gas readings recorded at: 31.8 `C/89.2 `F
As received Barometric Pressure recorded at: 22.1 °C/71.7 `F
As received gas check readings are only recorded if the instrument is received in a working condition.
Where the instrument is received damaged no reading can be taken.
Dace of Issue: 17 Aug 2021 Approved By Signatory
i
Craig McPherson
Laboratory Inspection
The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through MIST to the International system of
Units (SI). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory.
Cdb.a kuarlce: 112 IGC lnsuace: 112
Page 2 of 2�151NAMST-1.1
www.qedenv.com (800) 624-2026 info@qedenv.com
QED Environmental Systems Inc. 2355 Bishop Circle West, Dexter, MI 48130
ENVIRO-EQUIPMENT, INC.
LANDTEC GEM 5000 Plus CALIBRATION DATA SHEET
Serial Number G ,.1(DUL f1J(1) Date 0010-0172- Inspector �_
Time/DateQyl Batten Level f(b0fl.e, Memory Cleared Pump Faults
Gas Alarms: CH, = 100.0% �-A CO, = 100.0% 5.aS4 O, = 22.0% C)V_0v�
Zero Transducers Pump Flow Rate (0 46 C%rAiln Vacuum Tested To 80" H2O
Calibration Check (Perfornsed at Room Temperature)
Calibration Gas
Calibration Gas
Lot Number
Concentration
PureN,
� �
CR.-199
1L405Z-+c
High CH,
1EV1d
42�2
High CO2
?jS` 10
yZM-�
LowCH4
IS6lo
1283`-tZ'Z
Low CO2
I S°la
I'L31H22
Low 02
46%
302-4(D2'�4db9
High 02
20.9%
N/A
CO
soep,.,.,
ISI�I�2�
H,S
I o ppir",
1514�
Expiration
l 202S
0",12m2S
ok I iozS
tD14 2mZ
0.{ 1 2m2
04 2sD2
N/A
12 2-023
12 23
Reading Accuracy*
49.9o7a
p 3CS/J(e'olo
15. ry09o
I S. 0 la
01,
Z 1. 0110
l m RP_
2%
t2%
2%
=2%
_ 2oo
± 10%
10%
*Accuracy depends upon calibration range; I5%-FS range for CFI, & CO., 0-5 % volume for a, 0%-FS for H,S, and 10% of reading for CO.
INSPECTOR'S MAINTENANCE NOTES