Loading...
HomeMy WebLinkAbout6301_MooreCounty_MSWLF_CDLF_June2022LFG_FID1682002_20220610ENR USE ONLY—. j ❑Paper Report ❑Electronic Data - Email CD data loaded: Yes / No Doc/Event #: c DEIVR I I Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: • Prepare one form for each individually monitored unit. • Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). • Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. • Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): 5&ME, Inc. (on behalf of Moore County) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Edmund Q.B. Henriques Phone: 336-288-7180 E-mail: ehenriques@smeinc.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) June 7, 2022 Moore County Landfill 456 Turning Leaf Way, Aberdeen, NC 63-01 .0500 Environmental Status: (Check all that apply) Initial/Background Monitoring ❑x Detection Monitoring Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells x❑ Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data El water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. �x Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. 1 am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Edmund Q.B. Henriques, PG Senior Geologist, S&ME Inc. 336-312-3330 Facility Representative Name (Print) Title (Area Code) Telephone Number 6/10/2022 re Date 8646 W. Market Street, Suite 105, Greensboro NC 27409 Facility Representative Address F-0176 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 Affix NC Licens@04Professional Geologist Seal v � .41 0Cn 1216 Z 'L `ffi Q. B 9g�+�ceae: a no�e�,�dap�o. NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: June 7, 2022 NC Landfill Rule (.0500 or.1600): 0.0500 Sample Collector Name & Position: Ed Henriques / Senior Geologist, SWE, Inc. Gas Meter Type & Serial Number: GEM 5000 / SN G506450 Field Calibration Date & Time: 6/6/2022 Gas Meter Calibration Date: 8/16/2021 Field Calibration Gas Type (15115 or 35/50): 1 5/15 Field Calibration Gas Canister Expiration Date: 01 /2 02 5 Gas Meter Pump Rate: 676 cc/min Ambient Air Temperature: 85 Barometric Pressure (in. or mm Hg): 29.10" Weather Conditions: Partly Sunny Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location may or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions andlor Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 � volume � % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES GP-9 60 1211 120 0 0 0.0 19.5 11.2 0 Property Boundary Monitoring Point G P 10R 60 1221 120 0 0 0.0 18.2 2.2 0 Property Boundary Monitoring Point GP-1 1 60 1 226 120 0 0 0.0 11.6 7.2 0 Property Boundary Monitoring Point GP-1 2 60 1 251 120 0 0 0.0 20.6 0.6 0 Property Boundary Monitoring Point GP-1 3R 60 1306 120 0 0 0.0 19.4 11.8 0 Property Boundary Monitoring Point G P-14 R 60 1314 120 0 0 0.0 19.2 1.5 0 Property Boundary Monitoring Point GP-1 5R 60 1321 120 0 0 0.0 18.5 2.9 0 Property Boundary Monitoring Point GP-16 60 1328 120 0 0 0.0 11.6 1 0. 1 0 Property Boundary Monitoring Point GP-17 60 1336 120 0 0 0.0 9.0 12.5 0 Property Boundary Monitoring Point GP-18 60 1408 180 > 100 > 100 42.4 0.7 30.8 0 Property Boundary Monitoring Point GP-19 60 1351 120 0 0 0.0 16.8 4.7 0 Property Boundary Monitoring Point NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Senior Geologist / SWE, Inc. SIGNATURE TITLE Revised -March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: June 7, 2022 NC Landfill Rule (.0500 or.1600): 0.0500 Sample Collector Name & Position: Ed Henriques / Senior Geologist, S&ME, Inc. Gas Meter Type & Serial Number: GEM 5000 / SN G506450 Field Calibration Date & Time: 6/6/2022 Gas Meter Calibration Date: 8/16/2021 Field Calibration Gas Type (15115 or 35/50): 1 5/15 Field Calibration Gas Canister Expiration Date: 01 /2025 Gas Meter Pump Rate: 676 cc/min Ambient Air Temperature: 85 Barometric Pressure (in. or min Hg): 29.10" Weather Conditions: Partly Sunny Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location may or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 (volume) � % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES M W-6 60 1345 120 > 100 94 4.7 15.8 14.7 0 not a compliance point GV-33 60 1415 120 > 100 > 100 49.1 0.1 37.7 0 Passive vent, not a compliance point GV-34 60 1421 120 > 1 00 > 1 00 50.7 0.2 37.6 0 Passive vent, not a compliance point Scale House 60 1204 120 0 0 0.0 20.8 0.1 0 on -site structure Maintenance Shop 60 1242 120 0 0 0.0 20.5 0.1 0 on -site structure Transfer Station 60 1234 120 0 0 0.0 20.5 0.1 0 on -site structure Blake Residence 60 1506 120 0 0 0.0 21.0 0.1 0 off -site structure G P -2 0 60 1358 120 > 10 0 > 10 0 30.5 0.1 29.2 0 temporary monitoring point, west of cut-off trench G P-21 60 1431 120 > 100 > 100 56.5 0.1 39.3 0 temporary monitoring point, east of cut-off trench NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification includin the possibility of a fine and imprisonment. Senior Geologist / SWE, Inc. SIGNATURE V TITLE Revised -March 6, 2017 Table 1 Summary of 2020 & 2022 Methane Gas Readings Moore County Landfill (Permit 63-01) Moore County, North Carolina S&ME Project No. 4358-20-043A Location Scale- house g Point Type • 7 02/17/20 0.0% Maintena Shop • 0.0% Station • 0.0% Blake Crawlspace •V,f, 0.0% GP-9 0.0% r footn tel. 18.7% WUFMl! not installed 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% See footnote#2 0.0% 0.0% 0.0% 0.0% See footnote#1 11.9% Al 28.1% not installed r See footnote#4 not installed NEGEMEM See footnote#4 not installed 04/07/20 0.0% 0.0% 0.0% 0.0% 0.0% 32.2% not installed 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.4% 23.6% 59.9% not installed not installed not installed 09/15/20 0.1% 0.0% 0.0% 0.0% 0.1% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 0.0% 22.5% 0.0% not installed not installed 12/14/20 0.0% 0.0% 0.0% 0.1% 0.1% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.5% 9.6% 61.3% 0.0% not installed not installed 02/24/21 0.0% 0.0% 0.0% NM 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.4% 28.7% 67.9% 0.0% not installed not installed 04/12/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.2% 2.0% 21.8 % 0.0% not installed not installed 09/29/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.0% 19.5% 57.5% 0.0% not installed not installed 12/17/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 13.8% 27.8% 0.0% 10.1% 57.0% 03/25/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 29.1% 54.7% 0.0% 28.1% 56.4% 06/06/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 4.7% 42.4% 0.0% 30.5% 56.5% Notes: Monitoring Point Types: PB = Property Boundary, ONSS = On Site Structure, OFFSS = Off -site Structure Footnote#1 = MW-6 was replace by GP-19 as the property boundary compliance point. MW-6 is approximately 150 feet inside the property boundary and not a compliance point. Footnote#2 = GP-10 was replaced by GP-10R, GP-13 replaced by GP-13R, GP-14 replaced by GP-14R, GP-15 replaced by GP-15R Footnote#3 = Groundwater monitoring well MW-15 converted to gas monitoring point now identified as GP-18, which is a property boundary compliance point. Footnote#4 = Gas monitoring points installed for a cancelled active gas extraction pilot test. A new passive venting pilot test has been proposed. all measurements recorded in percent methane by volume Lower explosive limit of methane gas: 5% Upper explosive limit of methane gas: 15% Data recorded prior to 9/15/20 obtained by Golder not installed = Well not installed at the time of monitoring Yellow highlight cells and values in bold print indicate methane percent by volume greater than or equal to 5% at property boundary monitoring point Orange highlight cells and values in bold print indicate methane percent by volume greater than or equal to 1.25% inside structures. TAENV\Projects\2020W5&20-A -- County Routine 1.aWQMonitoring\Phase 01-QuarteriyMMM1ane Monitoring 2021-2022\-R-mgs-1I,-C- IN-RESfi 1. 6/10/2022 CERTIFICATION 11C � o� OF CALIBRATION ,��-'nM No. 66916 Date Of Calibration: 16-Aug-2021 Certificate Number: G506450_10/42343 Issued by: QED Environmental Systems Inc. Customer: ENVIRO EQUIPMENT INC 11180 DOWNS RD PINEVILLE, NC 28134 Description: Landtec Gas Analyzer Model: GEM5000 Serial Number: G506450 Accredited Results: Methane WHIM Certified Gas % Instrument Reading % Uncertain % 5.0 15.0 50.0 4.9 15.0 49.0 0.42 0.66 1.03 Carbon Dioxide CO2 Certified Gas % Instrument Reading % Uncertain 5.0 15.0 50.0 4.9 14.9 50.5 0.43 0.71 1.19 O en 02 Certified Gas N Instrument Reading % Uncertain % 20.5 20.6 0.25 Gas cylinders are traceable and details can be provided if requested. CH4, CO2 readings recorded at: 31.8 "C/89.2 °F Barometric Pressure: 0985"Hg/29.08 "Hg 02 readings recorded at: 22.1 `C/71.7 -F Method of Test : The analyzer is calibrated in a temperature controlled chamber using a series of reference gases, in compliance with procedure ISP17. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. The uncertainty evaluation has been carried out in accordance with NIST requirements. The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System of Units (9). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. Page Iof21 LPOISLNA IST-lA Cahbrvtiov IoSUYK: 112 iGC IvsmK: 112 www.qedenv.com (800) 624-2026 info@qedenv.com QED Environmental Systems Inc.,. 2355 Bishop Circie West, Dexter, MI 48130 M 7 CERTIFICATION OF CALIBRATION �'�- IQE No. 66916 Date Of Calibration: 16-Aug-2021 Certificate Number: G506450_10/42343 Issued by: QED Environmental Systems Inc. Non Accredited results: Pressure Transducers inches of water column Transducer Certified (Low) Reading (Low) Certified (High) Reading (High) Accuracy Static 0" 0" 40" 1 40.09" 1 2.0" Differential 0" 0" 4" 1 4.06" 1 0.7" Barometer mbar Reference Instrument Reading 0985 mbar 29.08 "Hg 0985 mbar 29.08 "H As received gas check readings: Methane CH4 Certified Gas % Instrument Reading % 5.0 4.8 15.0 14.6 50.0 48.6 Carbon Dioxide (CO2) Certified Gas ".6 Instrument Reading% 5.0 5.3 15.0 15.1 50.0 46.4 O en 02 Certified Gas % Instrument Reading % 20.5 20.5 As received Gas readings recorded at: 31.8 `C/89.2 `F As received Barometric Pressure recorded at: 22.1 °C/71.7 `F As received gas check readings are only recorded if the instrument is received in a working condition. Where the instrument is received damaged no reading can be taken. Dace of Issue: 17 Aug 2021 Approved By Signatory i Craig McPherson Laboratory Inspection The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through MIST to the International system of Units (SI). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. Cdb.a kuarlce: 112 IGC lnsuace: 112 Page 2 of 2�151NAMST-1.1 www.qedenv.com (800) 624-2026 info@qedenv.com QED Environmental Systems Inc. 2355 Bishop Circle West, Dexter, MI 48130 ENVIRO-EQUIPMENT, INC. LANDTEC GEM 5000 Plus CALIBRATION DATA SHEET Serial Number G ,.1(DUL f1J(1) Date 0010-0172- Inspector �_ Time/DateQyl Batten Level f(b0fl.e, Memory Cleared Pump Faults Gas Alarms: CH, = 100.0% �-A CO, = 100.0% 5.aS4 O, = 22.0% C)V_0v� Zero Transducers Pump Flow Rate (0 46 C%rAiln Vacuum Tested To 80" H2O Calibration Check (Perfornsed at Room Temperature) Calibration Gas Calibration Gas Lot Number Concentration PureN, � � CR.-199 1L405Z-+c High CH, 1EV1d 42�2 High CO2 ?jS` 10 yZM-� LowCH4 IS6lo 1283`-tZ'Z Low CO2 I S°la I'L31H22 Low 02 46% 302-4(D2'�4db9 High 02 20.9% N/A CO soep,.,., ISI�I�2� H,S I o ppir", 1514� Expiration l 202S 0",12m2S ok I iozS tD14 2mZ 0.{ 1 2m2 04 2sD2 N/A 12 2-023 12 23 Reading Accuracy* 49.9o7a p 3CS/J(e'olo 15. ry09o I S. 0 la 01, Z 1. 0110 l m RP_ 2% t2% 2% =2% _ 2oo ± 10% 10% *Accuracy depends upon calibration range; I5%-FS range for CFI, & CO., 0-5 % volume for a, 0%-FS for H,S, and 10% of reading for CO. INSPECTOR'S MAINTENANCE NOTES EEI GEM 2000 Plus Cal Form 01/12