Loading...
HomeMy WebLinkAbout09025_PTRP _BRF-A1a_SIR_2022.04.21 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 04/22/2022 1:33 PM I. Inspection Information Date & Time: 04/21/2022 9:50 AM Inspection Type: Drive-By Brownfields Staff: Kevin Slaughter, Tyler Pearson Other Personnel: N/A Location: Lat: 36.0984615, Long: -80.2393329, Brownfields Inspection Report: Piedmont Triad Research Park, 09025-05-034 04/21/2022 9:50 AM Page 2 of 5 II. Project Information Number: 09025-05-034 Name: Piedmont Triad Research Park Address: 401 E 3Rd St City: Winston Salem County: Forsyth III. Environmental Current Use of Property: Industrial Structures on Property: Yes Structures Violation: No Vapor Mitigation Systems: Not Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: Although there is an active vapor mitigation system installed within southeastern corner of the building, it was not entered during the Site Inspection. Summary: N/A Summary: Although there is a two-story brick structure located on the property, the western portion of the property which was the subject of the Site Inspection is vacant and semi-wooded (Photos 1-3). Summary: There is no exposed soil on the property. Brownfields Inspection Report: Piedmont Triad Research Park, 09025-05-034 04/21/2022 9:50 AM Page 3 of 5 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: There were no basements observed at the time of the Site Inspection. Summary: N/A Condition: None observed Summary: N/A No risk to the public observed at the time of the Site Inspection. Brownfields Inspection Report: Piedmont Triad Research Park, 09025-05-034 04/21/2022 9:50 AM Page 4 of 5 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Existing power pole and vicinity facing northwest across 3rd Street East. The Site Inspection was performed to determine if work had begun on the relocation of an existing Duke Energy power pole. Relocation of an existing power pole (shown in Photo 1) was granted In an April 8, 2022, BPMU email to Mr. David Witte with Duke Energy. The existing power pole (Photo 1) will be relocated approximately 35 feet north of its current location as shown in the attached stub pole relocation map. During the site visit, it was determined that no power pole relocation work had taken place prior to the inspection (Photos 1-3). Brownfields Inspection Report: Piedmont Triad Research Park, 09025-05-034 04/21/2022 9:50 AM Page 5 of 5 Photo 2: Photo of approximate power pole relocation area facing north. Guy wires from existing power pole are partially visible in the background. Photo 3: Close-up of existing power pole guy wires with yellow plastic covers. SCOPE OF WORK WO 42637298 -INSTALL ONE 55-3 WOOD POLE AT P2 -INSTALL (4) SPAN GUYS FROM EXISTING 80-2 WOOD POLE TO NEW 55-3 WOOD POLE -NEW P2 POLE WITH DOWN GUYS AND SPAN GUYS WILL PROVIDE ADEQUATE AND SAFE SUPPORT FOR EXISTING P1 911 ADDRESS 415 E 3RD ST, WINSTON-SALEM, NC 27101 COUNTY: FORSYTH COUNTY P2 - PROPOSED NEW 55' CLASS 3 WOOD POLE INSTALL SET DEPTH: 7.5' PROPOSED NEW (4) DOWN GUYS WITH LEAD LENGTHS OF 25',22',19', AND 15' GPS: 36.098503, -80.239289 PROPOSED NEW (4) SPAN GUYS FROM EXISTING P1 TO PROPOSED P2 LEGEND: EXISTING POLE EXISTING OVERHEAD 3PHASE CONDUCTOR (CIRCUIT 03461201) EXISTING OVERHEAD 3PHASE CONDUCTOR (CIRCUIT 03462408) PROPOSED POLE PROPOSED SPAN GUY PROPOSED DOWN GUYS LEGEND: EXISTING POLE EXISTING OVERHEAD 3PHASE CONDUCTOR (CIRCUIT 03461201) EXISTING OVERHEAD 3PHASE CONDUCTOR (CIRCUIT 03462408) PROPOSED POLE PROPOSED SPAN GUY PROPOSED DOWN GUYS PARCEL ID: 6835-37-9192.000