Loading...
HomeMy WebLinkAbout6301_MooreCounty_MSWLF_CDLF_March22LFG_FID1678530_20220524ENR USE ONLY: ❑Pa er Report ❑Electronic Data - Email CD data loaded: Yes / No Doc/Event #: C DEt R I I Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: • Prepare one form for each individually monitored unit. • Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 213 surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). • Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. • Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). • Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): S&ME, Inc. (on behalf of Moore County) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Edmund Q.B. Henriques Phone: 336-288-7180 E-mail: ehenriques@smeinc.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) March 25, 2022 Moore County Landfill 456 Turning Leaf Way, Aberdeen, NC 63-01 .0500 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring x❑ Detection Monitoring ❑ Assessment Monitoring ❑ Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells x❑ Groundwater monitoring data from private water supply wells El Leachate monitoring data ❑ Surface water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? 8 No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. x] Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Edmund Q.B. Henriques, PG Senior Geologist, S&ME Inc. 336-312-3330 Facility Representative Name (Print) k Title 4/27/2022 Signature r Date 8646 W. Market Street, Suite 105, Greensboro NC 27409 Facility Representative Address F-0176 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 (Area Code) Telephone Number Affix NC Lice r s / Pr rte i �al"Qgelogist Seal mj�tVc' a^ � yeoeeesaxa a ®W`�� 12 _ off,. U •' t 2-: � , Q. , 4 s0 � �, NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records "as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: March 25, 2022 NC Landfill Rule (.0500 or .1600): 0.0500 Sample Collector Name & Position: Ed Henriques / Senior Geologist, S&ME, Inc. Gas Meter Type & Serial Number: GEM 5000 / SN G507243 Field Calibration Date & Time: 3/23/2022 Gas Meter Calibration Date: 1 1 /4/2021 Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 01 /2025 Gas Meter Pump Rate: 712 cc/min Ambient Air Temperature: 68 Barometric Pressure (in. or min Hg): 29.30" Weather Conditions: Partly Sunny Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location man or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LEG Well ID S ample Purge T m of y Time Pumped (see) Initial /o LEL Stabilized /o LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES GP-9 60 1209 120 0 0 0.0 21.2 0.1 0 Property Boundary Monitoring Point G P 10 R 60 1215 120 0 0 0.0 18.8 2.0 0 Property Boundary Monitoring Point GP-1 1 60 1221 120 0 0 0.0 15.0 4.1 O Property Boundary Monitoring Point GP-12 60 1249 120 0 0 0.0 20.1 1.0 0 Property Boundary Monitoring Point GP-13R 60 1 302 120 0 0 0.0 20.3 0.7 0 Property Boundary Monitoring Point GP-14R 60 1309 120 0 0 0.0 17.0 2.0 0 Property Boundary Monitoring Point GP-15R 60 1 320 120 0 0 0.0 20.3 0.4 0 Property Boundary Monitoring Point G P-16 60 1329 120 0 0 0.0 9.6 10.0 0 Property Boundary Monitoring Point GP-17 60 1336 120 0 0 0.0 10.6 3.9 0 Property Boundary Monitoring Point G P-18 60 1402 180 > 100 > 100 54.7 0.2 37.2 0 Property Boundary Monitoring Point GP-19 60 1351 120 0 0 10.0 17.9 3.5 0 Property Boundary Monitoring Point NOTE: 1f needed, attach additional data forms to include additional LFG monitoring data locations for the facility. AcT1oN LEVELS: Methane: >1.25% by volume (inside structures) AND >.5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. 1 am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Senior Geologist / S&ME, Inc. SIGNATURE TITLE Revised -March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). FacilityName: Moore County Landfill Permit Number: 63-01 Sampling Date: March 25, 2022 NC Landfill Rule (.0500 or.1600): 0.0500 Sample Collector Name & Position: Ed Henriques / Senior Geologist, S&ME, Inc. Gas Meter Type & Serial Number: GEM 5000 / SN G507243 Gas Meter Calibration Date: 11 /4/2021 Field Calibration Date & Time: 3/23/2022 Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 01 /2025 Gas Meter Pump Rate: 712 cc/min Ambient Air Temperature: 68 Barometric Pressure (in. or mm Hg): 29.30" Weather Conditions: Partly Sunny Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions andlor Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (see) Initial % LEL Stabilized % LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES M W-6 60 1345 120 > 100 > 100 29.1 8.5 16.2 0 not a compliance point G V-33 60 1411 120 > 100 > 100 53.7 0.2 39.6 0 Passive vent, not a compliance point GV-34 160 1415 120 > 100 > 100 51.6 0.2 38.5 0 Passive vent, not a compliance point Scale House 60 1201 120 0 0 0.0 21.2 0.1 0 on -site structure Maintenance Shop 60 1238 120 0 0 0.0 20.9 0.1 0 on -site structure Transfer Station 60 1230 120 0 0 0.0 21.0 0.1 0 on -site structure Blake Residence 60 1502 120 0 0 0.0 22.1 0.0 0 off -site structure G P 2 0 60 1421 120 > 100 > 10 0 28.1 0.6 24.3 0 temporary monitoring point, west of cut-off trench GP-21 60 1429 120 >100 >100 56.4 0.1 39.8 0 temporary monitoring point, east ofcut-offtrench NOTE: /f needed, attach additional data forms to include additional LFG monitoring data locations for the facility. A( TION IAA LLS: Methane: >1.25% by volume (inside structures) AND >_5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Senior Geologist / S&ME, Inc. SIGNATURE TITLE Revised - March 6, 2017 Table 1 Summary of 2020 & 2022 Methane Gas Readings Moore County Landfill (Permit 63-01) Moore County, North Carolina S&ME Project No. 4358-20-043A Location Monitoring Point Type Scale- house ONSS it Maintenance Shop NSS Transfer Station ONSS Blake Crawlspace OFFSS GP-9 PB r PB -- footnote#2 r. PB J$B JJB PBJJPB See fo.tnot PB See footnote#2 PB PB See footnote#2 PB PBJJ PB See - - 15 GP 8 I seeDate PB 02/17/20 0.0% 0.0% 0.0% 0.0% 0.0% 18.7% not installed 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 11.9% 28.1% not installed 04/07/20 0.0% 0.0% 0.0% 0.0% 0.0% 32.2% not installed 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.4% 23.6% 59.9% not installed 09/15/20 0.1% 0.0% 0.0% 0.0% 0.1% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 0.0% 22.5% 0.0% 12/14/20 0.0% 0.0% 0.0% 0.1% 0.1% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.5% 9.6% 61.3% 0.0% 02/24/21 0.0% 0.0% 1 0.0% NM 0.0% abandoned 0.0% 1 0.0% 0.0% 1 abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.4% 28.7% 67.9% 0.0% 04/12/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.2% 2.0% 21.8% 0.0% 09/29/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.0% 19.5% 57.5% 0.0% 12/17/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 13.8% 27.8% 0.0% 03/25/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 29.1% 54.7% 1 0.0% Notes: Monitoring Point Types: PB = Property Boundary, ONSS = On Site Structure, OFFSS = Off -site Structure Footnote#1 = MW-6 was replace by GP-19 as the property boundary compliance point. MW-6 is approximately 150 feet inside the property boundary and not a compliance point. Footnote#2 = GP-10 was replaced by GP-10R, GP-13 replaced by GP-13R, GP-14 replaced by GP-14R, GP-15 replaced by GP-1511 Footnote#3 = Groundwater monitoring well MW-15 converted to gas monitoring point now identified as GP-18, which is a property boundary compliance point. all measurements recorded in percent methane by volume Lower explosive limit of methane gas: 5% Upper explosive limit of methane gas: 15% Data recorded prior to 9/15/20 obtained by Golder not installed = Well not installed at the time of monitoring Yellow highlight cells and values in bold print indicate methane percent by volume greater than or equal to 5% at property boundary monitoring point Orange highlight cells and values in bold print indicate methane percent by volume greater than or equal to 1.25% inside structures. T:\ENV\R jl \2020\4358-2 43A Moore C.-ty Routine LFG&WQ Mo ito,ing\Phase 04-Quarterly Methane NI-ito,ing 2021-2022\LFG Readings Tables and Ch- IN PROGREss.A. 4/27/2022 ENVIRQ-EQUIPMENT, INC. LANDTEC GEM 5000 Plus CALIBRATION DATA SHEET Serial Number G cJ(P—+Z-Li 2J Date m3l2� 1 ZZ Inspector 151D Time/DateC*0!.4 Battery Level ( °lo Memory Cleared _ 1(qlk Pump Faults Gas Alarms: CH, = 100.0% � CO, = 100.0% i OZ = 22.0% Q Zero Transducers Qkgak L Pump Flow Rate T L c �Mi r� Vacuum Tested To 80" HZOO Calibration Gas Pure N, High CH4 High CO2 Low CHa Low CO2 Low 02 High 02 CO HZS Calibration Check (Performed at Room Temperature) Calibration Gas Concentration >99 A999- son. 35°la I Sal. (Sol. gal. 20.9% Lot Number 14mb2-48 4202-b > 4 Ly202 AGL4 1203422_ 12-e>3 422 14e)'16qLk N/A Expiration 11 2fD25 �k I2 2S my2m2s Q 2-026 (25bl=Z6 Obi2.02.6 N/A m ZCb2 2� Reading Accuracy* 4Cb 570 L+9.0l9, S • to I S. mat. 4. cb'71. 2-. to f 10% t 10% *Accuracy depends upon calibration range; 15%FS range for CFG & CO2, 0-5% volume for 02, 0°/rFS for H2S, and 10% of reading for CO. INSPECTOR'S MAINTENANCE NOTES U1 GEM 20 Pluscal rmm 01/12 Date Of Calibration: 04-Nov-2021 PJLA c.uo.dunn No. 66916 Certificate Number: G507243_9/42945 Customer: Enviro Equipment Inc f 11180 Downs, Rd Pinevill, NC R8134 USA Description: Landtec Gas Analyzer Model: GEM5000 Serial Number: G507243 Accredited Results: _.i---- brunt Certified Gas % Instrument Reading % Uncertain % 5 0 4.9 0.42 15.0 14.9 0.66 50.0 49.1 1.03 5.0 15.1 Gas cylinders are traceable and details can be provided if requested. 4.8 i 0.43 14.8 0.71 CH4, CO2 readings recorded at: 30.4 `C/86.7 °F Barometric Pressure: 0992 mbar/29.30 "Hg 02 readings recorded at: 21.6 °C/70.8 °F Method of Test : The analyzer is calibrated in a temperature controlled chamber using a series of reference gases, in compliance with procedure ISP17. The reported expanded uncertainty is providing a level of confidence of app with NIST requirements. The calibration results published in this certificate were o� Units (SI). Certification only applies to results shown. This on a standard uncertainty multiplied by a coverage factor of k=2, itely 95%. The uncertainty evaluation has been carried out in accordance ng equipment capable of producing results that are traceable through NIST to the International System of may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. Cahbmloa inatmce: 112 IGC insmce 112 1 Peg, l of21 LPOISLNAMST-1.1 Date Of Calibration: 04-Nov-2021 Non Accredited results: PJLA GIIMaOon No. 66916 Certificate Number: G507243_9/42945 Pressure Transducers inches of water column Transducer Certified (Low) Reading (Low) Certified (High) Static Reading (High) Accuracy p p qp 39.87" 2.0" Differential I 0"1 0" 4" 3.98" 0.7" As received gas check readings: Methane CH4 Certified Gas % Instrument Reading 5.0 4,8 15.0 14.6 50.0 48.7 Carbon Dioxide CO2 Certified Gas % Instrument Readin 5.0 5.2 15.1 15.2 50.0 48.9 As received Gas readings recorded at: 30.4 °C/86.7 "F As received Barometric Pressure recorded at: 21.6-C/70.8 `F Date of Issue : 05 Nov 2021 Approved By Signatory Kyle Racine Laboratory Inspection The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System of Units (Sl). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. Ceu, mion N,itavice: 112 IOC rv=ce: 112 Page 2 01721 LK15LNANIST-1.1