Loading...
HomeMy WebLinkAbout21018_E Craighead Storage_SIR_2022.03.03 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 03/07/2022 9:18 AM I. Inspection Information Date & Time: 03/03/2022 1:45 PM Inspection Type: Drive-By Brownfields Staff: Kevin Slaughter Other Personnel: N/A Location: Lat: 35.2523067, Long: -80.7990488, Brownfields Inspection Report: East Craighead Storage, 21018-17-060 03/03/2022 1:45 PM Page 2 of 6 II. Project Information Number: 21018-17-060 Name: East Craighead Storage Address: 204 E Craighead Rd City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Residential Structures on Property: None Structures Violation: No Vapor Mitigation Systems: Not Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Observed Exposed Soils Violation: No Summary: An approved Vapor Mitigation Plan is in place for the redevelopment, though installation has not yet begun. Summary: N/A Summary: Future high density apartment buildings currently under construction (Photos 1 – 5). Summary: Site has been rough graded with concrete curbing around future parking areas partially installed on the southeastern portion of the property (Photos 1-4). Brownfields Inspection Report: East Craighead Storage, 21018-17-060 03/03/2022 1:45 PM Page 3 of 6 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: Diesel fuel AST's observed for construction equipment use (Photo 5). Although there was no sign of staining observed, there were no spill prevention measures observed at the time of the Site Inspection. The EMP does not specify requirements for AST storage. However, DEQ recommends that the ASTs be contained within a secondary storage unit. Condition: Summary: N/A No risk of public exposure observed at the time of the Site Inspection. Brownfields Inspection Report: East Craighead Storage, 21018-17-060 03/03/2022 1:45 PM Page 4 of 6 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: View facing north along E. Craighead Rd. The project manager requested a drive-by inspection to find out if site work had begun at the property. Site work was in progress upon arrival, with significant amount of grading having taken place. Concrete curbing installation has been started around future tenant parking areas, although it did not appear that any work had begun on the future apartment buildings (Photo 2 and 4). Brownfields Inspection Report: East Craighead Storage, 21018-17-060 03/03/2022 1:45 PM Page 5 of 6 Photo 2: View of property facing west along Philemon Ave. Photo 3: Photograph facing northeast along Philemon Ave. Brownfields Inspection Report: East Craighead Storage, 21018-17-060 03/03/2022 1:45 PM Page 6 of 6 Photo 4: View facing north from southeastern portion of property. Photo 5: Diesel fuel AST's used to refuel site equipment. No barrier or berm installed under/around tanks.