Loading...
HomeMy WebLinkAbout1808TTRANSFER_INSP_20220429FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 3 UNIT TYPE: Lined MSWLF LCID YW Transfer X Compost SLAS COUNTY: Catawba Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: 1808T-TRANSFER- CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE Date of Site Inspection: April 29, 2022 Date of Last Inspection: April 29, 2022 FACILITY NAME AND ADDRESS: City of Hickory Transfer Station 1050 1st Avenue Southwest Hickory, North Carolina 28601 GPS COORDINATES (decimal degrees): Lat.: 35.73126 Long.: -81.35588 FACILITY CONTACT NAME AND PHONE NUMBER: Name: Andrew Ballentine, Solid Waste Manager Telephone: (828) 323-7439 Email address: aballentine@hickorync.gov FACILITY CONTACT ADDRESS: Post Office Box 398 Hickory, North Carolina 28603 PARTICIPANTS: Andrew Ballentine, Solid Waste Manager – City of Hickory Lewis Berry, Solid Waste Supervisor – City of Hickory Charles Gerstell, NCDEQ – Solid Waste Section STATUS OF PERMIT: A Permit Approval to Operate 1808T-TRANSFER-, City of Hickory Transfer Station was issued to the City of Hickory on November 4, 2021. The permit approval is for the life of site, as defined in North Carolina General Statute 130A- 294(a2). PURPOSE OF SITE VISIT: Comprehensive Inspection STATUS OF PAST NOTED VIOLATIONS: N/A OBSERVED VIOLATIONS: None The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 3 ADDITIONAL COMMENTS 1. The facility consists of a Municipal Solid Waste Transfer Facility having a service area of the City of Hickory only. 2. All waste received at the facility is transferred to the Blackburn Resource Recovery Facility (Permit #18-03) for final disposal. 3. The Permit and Operations Plan were verified. Both documents were current and available upon request. 4. Waste screening reports were observed for January 2022 to present. Screenings were performed with adequate frequency and provided good documentation of observed unacceptable waste streams and final disposition of those wastes. x New screening frequency requirements effective January 2021 were discussed with facility staff during the inspection. 5. Transfer Station Operations Specialist Certifications: x Lewis Berry (expires 2/22/23) x Leopold Bodden (expires 9/15/22) x Randall Cline (expires 4/23/24) x Justin Gross (expires 4/23/24) x Michael Pisani (expires 9/15/22) 6. Gates were provided at the entrances to the facility to prevent unauthorized access. 7. All access roads surrounding the facility are paved and well maintained. 8. Waste is offloaded directly into waste hoppers by city vehicles. As waste is offloaded, transfer station attendants view the waste being deposited into the hoppers through one of two windows in the operator room. 9. The tipping floor was well managed. The floor was free of wastes and residues. Staff wash down the floor with hoses at multiple times throughout the working day. 10. Leachate drains within the floor of the facility were free of obstructions and appeared to be functioning properly. 11. No unacceptable waste streams were observed. 12. The walls of the facility were free of residue buildup. x Administrative Rules regarding pressure washing requirements effective January 2021 were discussed with facility staff. x These requirements are also detailed under General Facility Operation Condition #23(b) of the approved Permit to Operate. 13. Windblown waste was well managed. 14. Four fire extinguishers are mounted to the walls around the tipping floor in case of emergencies. All showed a full charge. 15. One bait box was provided along the edge of the tipping floor and additional bait boxes were provided along the exterior of the facility to assist in control of vectors. 16. Exterior drains within the paved and concrete areas on the south side of the facility deposit directly into the sanitary sewer system. x A small amount of vegetative debris was observed within the longer leachate drain closest to the building. Please ensure the interior of the drain is kept free of obstructions to ensure the device functions properly. x A buildup of residues was observed on the smaller leachate grates covering the leachate drains located under the waste trailers. Please ensure these grates are cleaned of residues to ensure leachate can properly enter the drains. 17. Per the Operations Plan, after each truck has unloaded and finished its route for the day, the trucks move from the tipping floor to the area where the compaction trailers are located to remove any debris from their clean-outs. This process is to be completed in an area that drains to the sanitary sewer system where it can be properly processed. Any debris left on the ground is to be cleaned up immediately and placed in the dumpster and or rollout containers provided in the designated area. The dumpster and rollout containers are to be emptied and deposited into the transfer station at the end of the working day. x The aforementioned area was well managed at the time of inspection. The surfaces surrounding the leachate drains at the trailer loading area were free of debris or residues. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 3 of 3 Please contact me if you have any questions or concerns regarding this inspection report. ________________________________________ Phone: (704) 235-2144 Charles T. Gerstell Environmental Senior Specialist Regional Representative Sent on: 5/4/22 X Email Hand delivery US Mail Certified No. [ _] Copies: Deb Aja, Western District Supervisor - Solid Waste Section Digitally signed by Charles T. Gerstell DN: cn=Charles T. Gerstell, o=Divsion of Waste Management, ou=Solid Waste Section, email=charles.gerstell@ncdenr.gov, c=US Date: 2022.05.04 11:14:17 -04'00'