HomeMy WebLinkAboutSLAS8214_PERMIT_RENEWAL_20220318
March 18, 2022
Mr. Arthur Wayne Cannady
C & C Septic Tank Service
1366 Bass Lake Road
Roseboro, NC 28382
RE: SLAS-82-14 Permit Renewal
C & C Septic Tank Service
SR 1237 in Sampson County
Dear Mr. Cannady:
The NC Division of Waste Management has reviewed your application to renew Septage Land Application Site Permit,
SLAS-82-14, in Sampson County. Your application has been approved in accordance with NC Septage Management
Rules and your permit, SLAS-82-14, is enclosed.
Please read all permit conditions carefully. The nutrient management and soil erosion and runoff control plans you
submitted have been incorporated into your permit. Do not exceed the maximum annual application rate listed within
Permit Condition 7 or the monthly application rates listed in your nutrient management plan. This permit shall expire
on March 18, 2032. An application for permit renewal must be submitted ninety (90) days prior to permit expiration.
Violations to NC Septage Management Rules or this permit could subject you to administrative penalties of up to
$15,000 per violation per day. If you have any questions concerning your permit or septage in general, please do not
hesitate to contact me at (919) 707-8283. When communicating to the Division about this permit, please refer to it
as "SLAS-82-14."
Sincerely,
Chester R. Cobb, Environmental Program Consultant
Division of Waste Management, NCDEQ
Enclosures
cc: Central Files
John Farnell, Environmental Specialist II, Wilmington Regional Office
Sampson County Health Department
Digitally signed by Chester R. Cobb
DN: cn=Chester R. Cobb, o=Solid Waste
Section, ou=DWM,
email=chester.cobb@ncdenr.gov, c=US
Date: 2022.03.18 14:35:19 -04'00'
Facility Permit No.: SLAS-82-14C & C Septic Tank Service
Permit to OperateMarch 18, 2022
Page 1of 4
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENTAL QUALITY
DIVISION OF WASTE MANAGEMENT
SOLID WASTE SECTION
PERMIT TO OPERATE A SEPTAGE LAND
APPLICATION SITE
C & C Septic Tank Service
Arthur Wayne Cannady
1366 Bass Lake Road
Roseboro, NC 28382
is hereby permitted to operate Septage Land Application Site with permit # SLAS-82-14 located on SR 1237 in
Sampson County at approximate position 34.96675° N latitude and -78.42153° Elongitude. This site is permitted
only for operations that are conducted in accordance with the representations made in the approved application,
with all conditions attached to this permit, and with all of the provisions of 15A NCAC 13B.0800 -- Septage
Management. Failure to operate as permitted may result in the Department suspending or revoking this permit, initiating action to enjoin the unpermitted operation, imposing administrative penalties, or invoking any other
remedy as provided in Chapter 130A, Article 1, Part 2 of the North Carolina General Statutes.
This permit shall be reviewed annually to determine if soil test results and management activities are in
compliance with the Septage Management Rules and the conditions of this permit. Modifications, where
necessary, shall be made in accordance with rules in effect at the time of review.
____________________________
Edward Mussler, Chief
Solid Waste Section
Division of Waste Management, NCDEQ
Digitally signed
by Edward F.
Mussler III, P.E.
Date: 2022.03.18
11:55:49 -04'00'
Facility Permit No.: SLAS-82-14 C & C Septic Tank Service Permit to Operate March 18, 2022
Page 2 of 4
CONDITIONS OF OPERATING PERMIT
1. This permit shall become void if the soils fail to adequately assimilate the septage and
shall be rescinded unless the site is maintained and operated in a manner which will
protect the assigned water quality standards of both surface and ground waters.
2. This site shall be operated and maintained in accordance with the nutrient management
plan submitted by Arthur Wayne Cannady and approved by the Division of Waste
Management. The 12.9-acre site has been established in Coastal Bermudagrass and
shall be overseeded with rye or ryegrass between September 1st and October 15th of
each year. Areas where the bermudagrass stands falls below 80% in coverage shall be
replanted in bermudagrass. The planting and harvest recommendations shall be
followed as outlined in the nutrient management plan. The 30-day waiting period
between the last application of septage, and the harvest of a crop shall be met by using
the permitted septage detention facility for temporary storage. All discharges shall occur
within the permitted area and shall be consistent with the crop rotation in the approved
plan.
3. This site shall be operated and maintained in accordance with the erosion and runoff
control plan submitted by Arthur Wayne Cannady in such a manner as to prevent the
migration of wastes off the designated waste receiving site. Any site improvements
noted in the plan must be installed within 30 days of plan approval. The installation of
groundwater monitoring wells shall be required as deemed necessary by the Division.
4. The issuance of this permit does not preclude the Permittee from complying with any
and all statutes, rules, regulations, or ordinances that may be imposed by other local,
state, and federal government agencies which have jurisdiction. It is the responsibility
of the Permittee to be in compliance with the Federal Regulations listed in the Code of
Federal Regulations, 40 CFR Part 503.
5. This permit may be modified or reissued at any time to incorporate any conditions,
limitations and/or monitoring requirements the Division deems necessary to adequately
protect the environment and public health.
Facility Permit No.: SLAS-82-14 C & C Septic Tank Service Permit to Operate March 18, 2022
Page 3 of 4
6. This site is only permitted for the land application of domestic septage (including
portable toilet waste) and grease septage. The pH of domestic septage shall be raised
to 12 or higher by alkali addition and, without the addition of additional alkali, shall
remain at 12 or higher for 30 minutes prior to land application as per 15A NCAC 13B
.0842(c)(1). The pH of grease septage or grease septage mixed with domestic septage
shall be raised to 12 or higher by alkali addition and, without the addition of additional
alkali, shall remain at 12 or higher for 2 hours prior to land application as per 15A NCAC
13B .0842(c)(2). Grease septage shall be diluted as required by 15A NCAC 13B
.0842(a)(14) when applied over perennial vegetation.
7. This site contains approximately 12.9 acres that are available for land application of
septage. The maximum annual application rate shall be 50,000 gallons per acre per
year. At this application rate, a maximum annual volume of 645,000 gallons may be
applied to this site. The maximum annual application rate assumes equal septage
distribution, on an annual basis, over the entire permitted area. Application rates to each
approved disposal field shall not exceed the maximum annual application rate or the
monthly application rates listed in the approved nutrient management plan.
8. An approved septage detention facility with a minimum design capacity of 13,000 gallons
shall be available prior to operation of this site as per 15A NCAC 13B .0838(a) unless an
approved wastewater treatment plant is available for use during periods of adverse
weather. The storage capacity may be adjusted if it is demonstrated during the operation
of the site that this volume of storage is inadequate.
9. Only the area designated on the attached site map shall be utilized for septage disposal.
Each load of septage discharged at the site shall be distributed from a moving vehicle in
such a manner that there is no standing water when the discharge is complete.
10. Septage shall not be applied during any precipitation event, or if there is standing water
on the soil surface, if the soil surface is frozen, or if the soil surface is snow covered. The
Permittee shall consider pending weather conditions when making the decision to land
apply in order to prevent any discharge of septage outside of the permitted boundary.
11. Septage shall not be applied during periods of high soil moisture. Septage applications
that will result in ruts greater than three inches in the soil surface are prohibited.
12. Any discharge of septage outside of the permitted boundaries via runoff, aerial drift, etc.
is prohibited.
Facility Permit No.: SLAS-82-14 C & C Septic Tank Service Permit to Operate March 18, 2022
Page 4 of 4
13. This permit shall become void unless the land application activities are carried out in
accordance with the conditions of this permit and in the manner approved by this
Division. No one other than the Permittee or an employee of the firm named in this
permit shall discharge septage at this site without prior appropriate notification and
written approval from the Division.
14. Prior to any transfer of this land, a notice shall be given to the new owner that gives full
details of the materials applied or incorporated at this site. The Division shall be notified
prior to site closure. This permit is non-transferable.
15. This permit shall expire on March 18, 2032. An application for permit renewal shall be
submitted at least ninety (90) days prior to the permit renewal date. When necessary,
an application for permit modification shall be submitted for any proposed change listed
in 15A NCAC 13B .0840(g). Along with the application for permit renewal or modification,
septage application records for the time this permit was valid shall be submitted.
16. Records shall be kept in accordance with 15A NCAC 13B .0842(e)(1) and the Code of
Federal Regulations, 40 CFR Part 503.17(b) to document all septage applications to the
site. These records shall be made available to a representative of the Division upon
request.
17. Any duly authorized officer, employee, or representative of the Division may, upon
presentation of credentials, enter and inspect any property, premises, or place on or
related to the disposal site and facility at any reasonable time for the purpose of
determining compliance with this permit; may inspect or copy any records that must be
kept under the conditions of this permit; or may obtain samples of groundwater, surface
water, or leachate.
18. Field separations in the nutrient management plan and all pertinent setbacks shall be
clearly located on the site. Boundaries of the permitted septage land application fields
shall be clearly marked on the ground.
19. The areas that can be used for land application of septage shall be maintained to meet
the minimum setback distances as described in 15A NCAC 13B .0841(d) such as 500
feet from any existing wells, residences, places of business, or places of public
assembly. Also, septage shall not be disposed of within 50 feet of any property line,
within 100 feet of any ditch, or within 200 feet of any surface water unless specified
otherwise.
#0
#0
!
G
500 ft
12.9 acres
500 ft
50 ft
50 ft
50 ft
Well
Abandoned well
House
House
SLAS-82-14 -
Source: Bing Maps aerial imagery, ESRI, (c) 2010 Microsoft Corporation and its data suppliers; site boundary, NC DENR Division of Waste Management.Map created by NC DENR Division of Waste Management, Compost and Land Application Branch for permitting purposes only.crc, August 2013
400 0 400200 Feet
SLAS-82-14
12.9 acres @ 50,000 gal/ac/yr 645,000 gal/yr
Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Site
12.9 12.9
645,000 0 0 0 0 0 645,000
YEAR
None 0 2017 238,500 645,000
Low 5,000 2018 265,800 645,000
Medium 10,000 2019 234,101 645,000
High 15,000 2020 387,000 645,000
2021 426,961 645,000
2022 25,000 645,000
Year:2017
Septage Grease PTW Applied Rate
Applied Rate
(gal/ac)Applied Rate
Applied Rate
(gal/ac)Applied Rate
Applied Rate
(gal/ac)
January 20,100 3,000 23,100 L 1,791 L #DIV/0!L #DIV/0!
February 17,200 7,000 24,200 L 1,876 L #DIV/0!L #DIV/0!
March 17,400 4,000 21,400 M 1,659 M #DIV/0!M #DIV/0!
April 12,800 3,000 15,800 H 1,225 M #DIV/0!M #DIV/0!
May 18,200 4,000 22,200 M 1,721 M #DIV/0!M #DIV/0!
June 22,100 1,000 23,100 H 1,791 H #DIV/0!H #DIV/0!
July 13,700 7,000 20,700 H 1,605 H #DIV/0!H #DIV/0!
August 14,900 5,000 19,900 M 1,543 H #DIV/0!H #DIV/0!
September 8,400 3,000 11,400 M 884 M #DIV/0!M #DIV/0!
October 9,500 8,000 17,500 L 1,357 M #DIV/0!M #DIV/0!
November 13,800 5,000 18,800 L 1,457 L #DIV/0!L #DIV/0!
December 18,400 2,000 20,400 L 1,581 L #DIV/0!L #DIV/0!
TOTAL 186,500 52,000 0 238,500 0 0
PUMPED:238,500 APPLIED:238,500 645,000 0 0
Max. Amount
ACRES
Monthly Rate
SITE SUMMARY
Over / Under
-406,500
-379,200
-410,899
Permit Amount
Field 2 Field 3
-258,000
-218,039
-620,000
Applied Amount
Field 1
Year:2018
Septage Grease PTW Applied Rate
Applied Rate
(gal/ac)Applied Rate
Applied Rate
(gal/ac)Applied Rate
Applied Rate
(gal/ac)
January 10,000 4,000 14,000 L 1,085 L #DIV/0!L #DIV/0!
February 16,800 7,000 23,800 L 1,845 L #DIV/0!L #DIV/0!
March 13,600 10,000 23,600 M 1,829 M #DIV/0!M #DIV/0!
April 13,200 3,000 16,200 H 1,256 M #DIV/0!M #DIV/0!
May 17,600 7,000 24,600 M 1,907 M #DIV/0!M #DIV/0!
June 19,400 3,000 22,400 H 1,736 H #DIV/0!H #DIV/0!
July 18,500 10,000 28,500 H 2,209 H #DIV/0!H #DIV/0!
August 11,200 4,000 15,200 M 1,178 H #DIV/0!H #DIV/0!
September 6,500 1,000 7,500 M 581 M #DIV/0!M #DIV/0!
October 22,100 7,000 29,100 L 2,256 M #DIV/0!M #DIV/0!
November 19,700 3,000 22,700 L 1,760 L #DIV/0!L #DIV/0!
December 32,200 6,000 38,200 L 2,961 L #DIV/0!L #DIV/0!
TOTAL 200,800 65,000 0 265,800 0 0
PUMPED:265,800 APPLIED:265,800 645,000 0 0
Year:2019
Septage Grease PTW Applied Rate
Applied Rate
(gal/ac)Applied Rate
Applied Rate
(gal/ac)Applied Rate
Applied Rate
(gal/ac)
January 14,000 9,000 23,000 L 1,783 L #DIV/0!L #DIV/0!
February 19,300 7,000 26,300 L 2,039 L #DIV/0!L #DIV/0!
March 16,500 7,000 23,500 M 1,822 M #DIV/0!M #DIV/0!
April 15,600 2,000 17,600 H 1,364 M #DIV/0!M #DIV/0!
May 13,300 9,000 22,300 M 1,729 M #DIV/0!M #DIV/0!
June 8,300 3,000 11,300 H 876 H #DIV/0!H #DIV/0!
July 11,200 7,000 18,200 H 1,411 H #DIV/0!H #DIV/0!
August 10,200 7,000 17,200 M 1,333 H #DIV/0!H #DIV/0!
September 8,400 4,000 12,400 M 961 M #DIV/0!M #DIV/0!
October 28,900 11,000 39,900 L 3,093 M #DIV/0!M #DIV/0!
November 20,401 2,000 22,401 L 1,737 L #DIV/0!L #DIV/0!
December 0 0 0 L 0 L #DIV/0!L #DIV/0!
TOTAL 166,101 68,000 0 234,101 0 0
PUMPED:234,101 APPLIED:234,101 645,000 0 0
Field 1 Field 2 Field 3
Field 1 Field 2 Field 3
Year:2020
Septage Grease PTW Applied Rate
Applied Rate
(gal/ac)Applied Rate
Applied Rate
(gal/ac)Applied Rate
Applied Rate
(gal/ac)
January 31,000 7,000 38,000 L 2,946 L #DIV/0!L #DIV/0!
February 25,000 6,500 31,500 L 2,442 L #DIV/0!L #DIV/0!
March 24,000 1,000 25,000 M 1,938 M #DIV/0!M #DIV/0!
April 25,000 1,500 26,500 H 2,054 M #DIV/0!M #DIV/0!
May 35,800 1,500 37,300 M 2,891 M #DIV/0!M #DIV/0!
June 37,800 7,800 45,600 H 3,535 H #DIV/0!H #DIV/0!
July 24,700 7,000 31,700 H 2,457 H #DIV/0!H #DIV/0!
August 33,000 6,000 39,000 M 3,023 H #DIV/0!H #DIV/0!
September 16,000 1,000 17,000 M 1,318 M #DIV/0!M #DIV/0!
October 34,200 8,000 42,200 L 3,271 M #DIV/0!M #DIV/0!
November 15,000 4,000 19,000 L 1,473 L #DIV/0!L #DIV/0!
December 28,200 6,000 34,200 L 2,651 L #DIV/0!L #DIV/0!
TOTAL 329,700 57,300 0 387,000 0 0
PUMPED:387,000 APPLIED:387,000 645,000 0 0
Year:2021
Septage Grease PTW Applied Rate
Applied Rate
(gal/ac)Applied Rate
Applied Rate
(gal/ac)Applied Rate
Applied Rate
(gal/ac)
January 40,000 5,500 45,500 L 3,527 L #DIV/0!L #DIV/0!
February 39,000 5,000 44,000 L 3,411 L #DIV/0!L #DIV/0!
March 42,501 5,000 47,501 M 3,682 M #DIV/0!M #DIV/0!
April 25,100 7,000 32,100 H 2,488 M #DIV/0!M #DIV/0!
May 27,000 1,000 28,000 M 2,171 M #DIV/0!M #DIV/0!
June 24,000 10,000 34,000 H 2,636 H #DIV/0!H #DIV/0!
July 18,820 7,000 25,820 H 2,002 H #DIV/0!H #DIV/0!
August 38,000 6,000 44,000 M 3,411 H #DIV/0!H #DIV/0!
September 24,000 9,040 33,040 M 2,561 M #DIV/0!M #DIV/0!
October 24,000 7,000 31,000 L 2,403 M #DIV/0!M #DIV/0!
November 23,000 7,000 30,000 L 2,326 L #DIV/0!L #DIV/0!
December 25,000 7,000 32,000 L 2,481 L #DIV/0!L #DIV/0!
TOTAL 350,421 76,540 0 426,961 0 0
PUMPED:426,961 APPLIED:426,961 645,000 0 0
Field 2 Field 3
Field 1 Field 2 Field 3
Field 1
Year:2022
Septage Grease PTW Applied Rate
Applied Rate
(gal/ac)Applied Rate
Applied Rate
(gal/ac)Applied Rate
Applied Rate
(gal/ac)
January 18,000 7,000 25,000 L 1,938 L #DIV/0!L #DIV/0!
February L 0 L #DIV/0!L #DIV/0!
March M 0 M #DIV/0!M #DIV/0!
April H 0 M #DIV/0!M #DIV/0!
May M 0 M #DIV/0!M #DIV/0!
June H 0 H #DIV/0!H #DIV/0!
July H 0 H #DIV/0!H #DIV/0!
August M 0 H #DIV/0!H #DIV/0!
September M 0 M #DIV/0!M #DIV/0!
October L 0 M #DIV/0!M #DIV/0!
November L 0 L #DIV/0!L #DIV/0!
December L 0 L #DIV/0!L #DIV/0!
TOTAL 18,000 7,000 0 25,000 0 0
PUMPED:25,000 APPLIED:25,000 645,000 0 0
Field 1 Field 2 Field 3