Loading...
HomeMy WebLinkAbout24043_Gas Fired Products_SIR_2022.03.23 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 03/28/2022 10:20 AM I. Inspection Information Date & Time: 03/23/2022 10:20 AM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter Other Personnel: Andrew Besu - Hart & Hickman (H&H) Location: Lat: 35.21105436413712, Long: -80.86774482577316, Brownfields Inspection Report: Gas Fired Products (RN), 24043-20-060 03/23/2022 10:20 AM Page 2 of 7 II. Project Information Number: 24043-20-060 Name: Gas Fired Products (RN) Address: 421 W. Tremont Avenue City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Residential Structures on Property: New Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Observed Exposed Soils Violation: No Summary: Vapor barrier visibe along some exterior soil contact walls. Spent majority of the inspection discussing soil contact wall treatment on the southeast portion of the property. See Use Of Basements and Inspector Comments section. Summary: N/A Summary: High Density apartment building currently under construction. Summary: Consistant with EMP and with site construction activities Brownfields Inspection Report: Gas Fired Products (RN), 24043-20-060 03/23/2022 10:20 AM Page 3 of 7 Use of Basements: Observed Basement Violation: Unknown Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: Soil contact walls observed along southeastern portion of building (Photos 1 – 6). One wall has exposed exterior VIMS barrier prior to backfilling, which will be wrapped around corner following site discussions to cover mechanical room (Figures 2 and 3). As described in photos 4 and 5, soil contact walls backfilled prior to installing VIMS barrier on exterior of wall. Following site discussion, H&H to propose installing VIMS barrier on inside of concrete walls Summary: N/A Condition: Summary: N/A No risk to the public observed at the time of the Site Inspection Brownfields Inspection Report: Gas Fired Products (RN), 24043-20-060 03/23/2022 10:20 AM Page 4 of 7 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: View of site from Tremont St. facing southeast Site Inspection performed at the request of Andrew Besu with H&H, who wanted to discuss soil contact wall issues covered previously. While onsite, it was determined that one barrier needed to be extended around a mechanical room to the parking deck, and potential soil contact wall treatment discussed on other locations on eastern side of building. Brownfields Inspection Report: Gas Fired Products (RN), 24043-20-060 03/23/2022 10:20 AM Page 5 of 7 Photo 2: Vertical VIMS barrier installed along eastern soil contact wall. Photo 3: Barrier in Photo 2 will be wrapped around corner of mechanical room. Parking deck in contact with remainder of soil contact wall and will not have a VIMS barrier installed. Brownfields Inspection Report: Gas Fired Products (RN), 24043-20-060 03/23/2022 10:20 AM Page 6 of 7 Photo 4: Soil contact wall on southeastern portion of property which was backfilled without VIMS barrier being installed on exterior wall. Photo 5: Another view of Photo 4. Discussed the installation of VIMS barrier along inside of wall, which will tie into vapor barriers proposed for top and bottom of walls. False wall to be installed over barrier. Planned revision to be submitted to DEQ prior to installation. Brownfields Inspection Report: Gas Fired Products (RN), 24043-20-060 03/23/2022 10:20 AM Page 7 of 7 Photo 6: View from Tremont Ave facing southeast. Was told in field that soil contact wall with bracing was backfilled prior to barrier being installed and H&H was currently working with Mr. Kelly Johnson with DEQ Brownfields to find a resolution. Photo 7: Reviewing site plans in job trailer