HomeMy WebLinkAbout23057_CharlotteVan&Storage_SIR_20220323
DWM Brownfields Inspection Report
Submitted By: jkslaughter_ncdenr
Submitted Time: 03/24/2022 10:41 AM
I. Inspection Information
Date & Time: 03/23/2022 9:28 AM Inspection Type: Meeting
Brownfields Staff:
Kevin Slaughter
Other Personnel:
Shannon Switch - Hart & Hickman (H&H)
Location:
Lat: 35.1829043, Long: -80.8817818,
Brownfields Inspection Report: Charlotte Van and Storage Co (RN), 23057-19-060
03/23/2022 9:28 AM
Page 2 of 7
II. Project Information
Number: 23057-19-060 Name: Charlotte Van and Storage Co (RN)
Address: 213 Verbena St.;
4607, 4615 Gilead St.
City: Charlotte
County: Mecklenburg
III. Environmental
Current Use of Property: Residential
Structures on Property: New Structures Violation: No
Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No
Use of Surface Water or Groundwater: Not Observed Water Use Violation: No
Exposed Soils: Observed Exposed Soils Violation: No
Summary: Sub-slab solid and slotted piping, riser stub-ups, temporary monitoring points,
gravel, and soil contact wall vapor barrier observed during the Site Inspection
Summary: N/A
Summary: New apartment building currently under construction
Summary: Consistent with EMP, and property development activities.
Brownfields Inspection Report: Charlotte Van and Storage Co (RN), 23057-19-060
03/23/2022 9:28 AM
Page 3 of 7
Use of Basements: Observed Basement Violation: No
Storage of Chemicals: Not Observed Chemical Violation: No
Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No
Current Exposure to Public/Public Risk:
Summary: lower-level soil contact walls are present on Building 2 which was inspected.
The VaporBlock 20 VI barrier was visible at the top of the vertical walls (already backfilled
against), and appeared in good condition
Summary: N/A
Condition:
Summary: N/A
None observed at the time of the site inspection.
Brownfields Inspection Report: Charlotte Van and Storage Co (RN), 23057-19-060
03/23/2022 9:28 AM
Page 4 of 7
IV.Inspector Comments
V.PHOTOGRAPHS
Photo 1: Second level barrier inspection. Vertical VIMS barrier overlapping edge of stone
visible in photo.
Site inspection performed to observe H&H sub-slab piping inspection on the upper level
of Building 2. During Site Inspection, VIMS piping and washed stone base appeared to
be clean, and in good condition (Photos 1-5). The 2” dia. PVC monitoring points observed
were temporary points, with permanent ones to be installed later (Photo 4). This is the
second level of Building 2, with lower level having soil contact walls (Photos 1 and 6).
The VIMS barrier exposed at the top of these soil contact walls also appeared to be in
good condition, with plenty of barrier material available to tie in upper-level horizontal
barrier.
Brownfields Inspection Report: Charlotte Van and Storage Co (RN), 23057-19-060
03/23/2022 9:28 AM
Page 5 of 7
Photo 2: VIMS piping covered with washed stone.
Photo 3: Exposed VIMS and gravel layer.
Brownfields Inspection Report: Charlotte Van and Storage Co (RN), 23057-19-060
03/23/2022 9:28 AM
Page 6 of 7
Photo 4: Section of slotted suction piping (solid where crossing footer trench), with
2” dia. PVC temporary monitoring point on right side of photograph.
Photo 5: Solid piling and vertical riser stub-up in center of footer location.
Brownfields Inspection Report: Charlotte Van and Storage Co (RN), 23057-19-060
03/23/2022 9:28 AM
Page 7 of 7
Photo 6: Vertical soil contact walls and VIMS barrier from another angle.