Loading...
HomeMy WebLinkAbout4101_Guilford_HighPoint_MSWLF_Seaboard_Feb22LFG_FID1656880_20220321DocuSign Envelope ID: F891B284-C2A3-40E4-B54F-660A4FB8B374 DENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Smith Gardner, Inc. Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Seth C. Rickerts, PG E-mail: seth@smithgardnerinc.com Phone: (919) 828 - 0577 x135 NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) High Point Riverdale Closed MSW Riverdale Drive, High Point, NC 41-01 .0500 February 16, 2022 Landfill Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑X Detection Monitoring ❑ Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data El water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Seth C. Rickerts, PG Project Geologist (919) 828 - 0577 x135 Name (Print) Title (Area Code) Telephone Number C_ lt,4� tes 3/10/2022 Affix NC Licensed/ Professional Geologist Seal Date 14 N. Boylan Ave, Raleigh, NC 27603 Facility Representative Address F-1370 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 a` yi. nl.}{�rrr. rr r rEN S rAL 3/1 10 022 2758 r DocuSign Envelope ID: F891B284-C2A3-40E4-B54F-660A4FB8B374 This page intentionally left blank. DocuSign Envelope ID: F89lB284-C2A3-40E4-B54F-660A4FB8B374 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: City of High Point Closed Riverdale Landfill Permit Number: 41-01 Date of Sampling: 2/16/2022 NC Landfill Rule (0500 or .1600): .0500 Name and Position of Sample Collector: Michael J. Liebl - Staff Environmental Technician Type and Serial Number of Gas Meter: GEM 5000, R8200045 Calibration Date of Gas Meter: 12/2021 Date and Time of Field Calibration: 2/16/2022, 0912 Type of Field Calibration Gas (15/15 or 35/50): 15/15 Expiration Date of Field Calibration Gas Canister: N/A Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 43 F Barometric Pressure: 29.55 in Hg General Weather Conditions: Sunny Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 LocaEDn or LFG V4 a ID Sample Tube Purge Time Time Pimiped (s) Initial %LEL Stabilized °•oLEL %CFI4 by Volume %02 %CO-2 Notes H2 S ppm 1-1 >60s 1023 >60s 0 0 0.0 20.1 0.5 0 LFG 3 >60s 1026 >60s 0 0 0.0 20.4 0.3 0 LFG 4 >60s 1032 >60s 2 2 0.1 17.8 1.8 0 LFG 5 >60s 1036 >60s 0 0 0.0 19.3 0.6 0 LFG 6 >60s 1039 >60s 6 6 0.3 19.4 0.8 0 LFG 7 >60s 1116 >60s 682 682 34.1 6.0 21.4 0 7-1 >60s 1120 >60s 286 286 14.3 12.8 15.1 0 7-2 >60s 1114 >60s 0 0 0.0 20.4 0.6 0 7-3 >60s 1113 >60s 2 2 0.1 20.2 1.0 0 74 >60s 1110 >60s 896 896 44.8 1.7 27.6 0 LFG 8 >60s 1105 >60s 194 194 9.7 1.9 18.4 0 LFG 8A >60s 1107 >60s 342 342 17.1 16.3 7.0 0 LFG 8B >60s 1108 >60s 110 110 5.5 15.6 4.7 0 8-1 >60s 1103 >60s 1268 1268 63.4 0.7 28.1 0 8-2 >60s 1101 >60s 1254 1254 62.7 1.6 31.7 0 8-3 >60s 1058 >60s 962 962 48.1 4.0 31.2 0 8-4 >60s 1050 >60s 696 696 34.8 1.5 35.0 0 8-5 >60s 1052 >60s 290 290 14.5 3.2 21.9 0 LFG 9 >60s 1054 >60s 46 46 2.3 19.6 1.4 0 9-1 >60s 1056 >60s 286 286 14.3 7.0 16.2 0 LFG 10 >60s 1132 >60s 2 2 0.1 19.2 3.5 0 Old Maint Bldg >60s 1041 >60s 0 0 0.0 20.9 0.1 0 Electrical Shop >60s 1043 >60s 0 0 0.0 20.9 0.1 0 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Staff Environmental Technician SIGNATURE TITLE DocuSign Envelope ID: F891B284-C2A3-40E4-B54F-660A4FB8B374 This page intentionally left blank. DocuSign Envelope ID: F891B284-C2A3-40E4-B54F-660A4FB8B374 G Q O M O M O O N N N x E 0_ U c ^O LL I L i U) N i O Z O U z C O a_ L Ln U N 0 d_ T ! N • Ark t� Y ' Y L V 49 �. IP + YY 4 110- V LFG-5 LFG-3 ' LFG-4 + 5 O LFG Probes 300 150 0 300 Feet it �•'� h n f+�* �� �;� - � ~ - ,- r . K r ��• "�}TiR�i •�. �RVL_ d 4P... r . "Ol 7-3 7-4 LFG-8 g_1 8-3 ° 8B 7.1 LFG-7 7-2 8A�• LFG-9 PAL— Jt_* LFG-10 0 h e ' cn Z O J U In O za Z Q Z w � O m J a o a o O a p� = tU Z > 0 O O Q O L Z C V 2 O LL LIA J r