Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1107_Buncombe_MSWLF_CDLF_Oct21GW_FID1655529_20220315
DEN R USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Bunnell-Lammons Engineering, Inc. (consultant) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Andrew W. Alexander. PG RSM Phone: (864)288-1265 E-mail: andy.alexander(cDblecorp.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) 1107-MSWLF Buncombe County Landfill 81 Panther Branch Road -1996 .1600 Alexander, NC, 28701 1107-CDLF .0500 October 26-28, 2021 -1998 0 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑X Detection Monitoring ❑ Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑ Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data El water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? No. No groundwater or surface water standards were exceeded. X Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑ Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Andrew W. Alexander, PG RSM Consultant Hydrogeologist (864) 288-1265 Facility Representative Name (Print) Title (Area Code) Telephone Number �� w a• �E,o•,....=a•d,a „®e,•o,owm, 3/15/2022 Signature Date 6004 Ponders Court, Greenville, SC, 29615 Facility Representative Address C-284 & C-1538 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 Affix NC Licensed/ Professional Geologist Seal i NS�c'titi9 1 5 Aul- LOG M' W A��♦ 1 jI f 1111111"O'k WATER QUALITY REPORT 2nd SEMI-ANNUAL EVENT 2021 BUNCOMBE COUNTY LANDFILL ALEXANDER, NORTH CAROLINA Permit No. 1107-MSWLF-1996 Permit No. 1107-CDLF-1998 Prepared For: Buncombe County BLE Project Number J21-9378-26 March 7, 2022 ���"I 1CAR Ns I �y 1 5 rLo6` 1nI#JIII% +'` BLE North Carolina Business Licenses C-284 & C-1538 IM BUNNELL LAMMONS ENGINEERING 6G04 Ponders Court I Grppnville, SC 29515 `864.2OH.1265 e 864.28 AKA N_P. into @Nerorp.mm BLECORRCOM IM I BUNNELL � LAMMONS ENGINEERING March 7, 2022 Buncombe County Solid Waste Department 81 Panther Branch Road Alexander, North Carolina 28701 Attention: Ms. Kristy Smith Subject: Water Quality Report 2°d Semi -Annual Event 2021 Buncombe County Landfill Alexander, North Carolina Permit Nos. 1107-MSWLF-1996 & 1107-CDLF-1998 BLE Project Number J21-9378-26 Dear Ms. Smith: Pursuant to authorization of Bunnell-Lammons Engineering, Inc. (BLE) Proposal Number J21-9378-26, dated June 22, 2021, BLE has prepared this water quality report for the 2t'd semi-annual sampling event of 2021 at the Buncombe County Landfill. Consistent with the North Carolina Division of Waste Management (DWM) — Solid Waste Section (SWS) approved monitoring program, sampling and analysis was conducted twice in 2021. This report contains the information required by the DWM to document the sampling and analysis activities for the second event of 2021 in the State's permanent project record. Sincerely, BUNNELL LAMMONS ENGINEERING INC. Ril . �Bla_is, Staff Hydrogeologist cc: Ms. Jaclynne Drummond — DWM-ARO d4/ Andrew W. Ale der, P.G., RSM Consultant Hydrogeologist Registered, NC # 1475 Ilblegvlsvrllsolidwasteprojectslbuncombe county active d( nc19378-26a fy22 fall 2021 reportW5 reportlactive bclf 1107-mswlf--1996 2nd 2021 semi-annual 9378-26. docx ' 6004 Ponders Court, Greenville, SC 29615 '%864,28B,1255 6'�864,288,4430 info@bleEorp,LCm BLECORP.COM 1s 1m 1i Water Quality Report — 2nd Semi -Annual Event 2021 March 7, 2022 Buncombe County Landfill —Alexander, North Carolina BLE Project No. J21-9378-26 TABLE OF CONTENTS 1.0 PROJECT INFORMATION........................................................................................................1 2.0 FIELD ACTIVITIES, SAMPLING, AND ANALYSIS.............................................................1 3.0 GROUNDWATER FLOW........................................................................................................... 2 4.0 RESULTS....................................................................................................................................... 2 4.1 Groundwater.................................................................................................................................... 2 4.2 Surface Water.................................................................................................................................. 2 4.3 Leak Detectors and Leachate Samples............................................................................................. 2 5.0 CONCLUSIONS AND RECOMMENDATIONS.......................................................................3 6.0 QUALIFICATIONS OF REPORT.............................................................................................. 3 7.0 CLOSING.......................................................................................................................................3 Tables Table 1 SWS Approved Sampling Matrix Table 2 Well Construction and Monitoring Well Data Table 3 Range of Groundwater Flow Velocities Table 4 Groundwater VOCs Table 5 Groundwater Field Parameters, Geochemical Parameters, and Total Metals Table 6 Surface Water VOCs Table 7 Surface Water Field Parameters and Total Metals Table 8 Leak Detector and Leachate VOCs Table 9 Leak Detector and Leachate Field Parameters and Total Metals Figures Figure 1 Site Location Map Figure 2 Groundwater Elevation Contour Map — October 25 — 26, 2021 Appendices Appendix A Field Sampling Logs — Pace Analytical Services, LLC. Appendix B Laboratory Analytical Data — Pace Analytical Services, LLC. iofi 1s 1m 1i Water Quality Report — 2nd Semi -Annual Event 2021 Buncombe County Landfill —Alexander, North Carolina 1.0 PROJECT INFORMATION March 7, 2022 BLE Project No. J21-9378-26 The subject 654-acre landfill site is located in Buncombe County, North Carolina, approximately nine miles north of the city of Asheville with a physical address of 81 Panther Branch Road in Alexander, North Carolina. Buncombe County owns and operates a Subtitle D MSWLF which includes Cell 1 through Cell 6 and a CDLF consisting of Phase 1 through Phase 6. Currently Cell 6 of the MSWLF and Phase 6 of the CDLF are the active waste units. MSWLF Cell 7 and CDLF Phase 7 have been permitted for construction and MSWLF Cells 8 through 10 are planned (but not permitted) for future expansion. A Water Quality Monitoring Plan (WQMP) was finalized by BLE and submitted to the North Carolina Solid Waste Section (SWS). The WQMP was approved on April 16, 2021 (FID 1576846). The facility requires semi-annual groundwater, surface water, and leachate monitoring and reporting in accordance with the WQMP. Semi-annual sampling is typically conducted each April and October and those events are designated "Spring" and "Fall," respectively. This report represents the 2nd semi-annual (Fall) sampling event of 2021. The existing groundwater monitoring network for the Buncombe County Landfill consists of two (2) upgradient (background) wells (MW-1 and MW-1D) and twenty-four (24) downgradient (compliance) wells (MW-2, MW-213, MW-3R, MW-4, MW-413, MW-5, MW-513, MW-6, MW-7, MW-8, MW-81), MW-10, MW-IOD, MW-11, MW-11D, MW-12, MW-121), MW-13, MW-13D, MW-14, MW-14D, MW-17R, MW- 17DR, and MW-18). Wells MW-17 and MW-17D were abandoned September 14, 2020 and replaced by MW-17R and MW-17DR respectively. Wells MW-15 and MW-15D were removed as compliance points and replaced by MW-18 as approved by the SWS on August 3, 2021 (FID 1595460). The MW-151MW-15D well pair remains in place for the collection of water levels only. The current SWS approved sampling matrix is included as Table 1. In accordance with Rule .0602 and Rule .0544(c), eight (8) surface water monitoring locations have been established for the facility to monitor surface water quality surrounding the existing waste footprint (Table 1). The existing surface water locations consist of one (1) upstream (background) point (SW-1) and seven (7) downstream (compliance) points (SW-2 through SW-8). In accordance with Rule .1626(12)(c), eight (8) active leachate sampling locations have been established for the facility (Table 1). The locations include six (6) existing leak detection sampling locations associated with each MSWLF cell (Cells 1 through 6) designated LD-1 through LD-6, one (1) leachate leak detection sampling location near the leachate pond designated Leachate LD, and the Leachate Pond itself. 2.0 FIELD ACTIVITIES, SAMPLING, AND ANALYSIS Groundwater, surface water, and leachate samples were collected for the 2nd semi-annual sampling event by personnel from Pace Analytical Services, LLC. (Pace) of Asheville, North Carolina between October 26-28, 2021. Groundwater samples were collected from the groundwater monitoring well locations located on the site as specified on Table 1. The seven (7) of the eight (8) surface water locations were sampled during the event. Surface water location SW-7 was dry at the time of sampling; therefore, no sample was collected. Additionally, the seven (7) leak detection and one (1) leachate pond locations were sampled. The groundwater, surface water, and leachate samples were delivered and analyzed in Pace's Columbia, South Carolina laboratory for the constituents in the approved matrix (Table 1). The field parameters of dissolved oxygen, pH, redox potential, specific conductance, turbidity, and temperature were measured in the field by 1 of 3 1s 1M 1i Water Quality Report — 2nd Semi -Annual Event 2021 Buncombe County Landfill —Alexander, North Carolina March 7, 2022 BLE Project No. J21-9378-26 Pace. A copy of the Pace field sampling logs is included in Appendix A. A copy of the laboratory analytical data is included in Appendix B. kxi=" .Z111 0 IWii/:r 104 451 y 1ClliiVA The water level data collected during the groundwater sampling event on October 25-26, 2021 is presented in Table 2. Groundwater flow velocity estimates are presented on Table 3. A groundwater elevation contour map is presented as Figure 2 which includes generalized groundwater flow directions. 4.0 RESULTS 4.1 Groundwater The results of the groundwater field and laboratory analyses are summarized on Tables 4 and 5 and the laboratory analytical data is included in Appendix B. Please refer to Tables 4 and 5 for a summary of which groundwater constituents exceeded North Carolina Groundwater Quality Standards (NC2L) maximum contaminant levels' (MCLs). Field parameters measured in the groundwater included pH, specific conductance, turbidity, and temperature. The field parameter of pH was below its NC2L standard in thirteen (13) wells. However, previous semi-annual reports for the subject site indicate that pH frequently varies between values both below and within the NC2L standards in the majority of the wells on site. No other field parameters were outside their NC2L standard limits for groundwater, if established. 4.2 Surface Water The results of the surface water field and laboratory analyses are summarized on Tables 6 and 7 and the laboratory analytical data is included in Appendix B. Please refer to Table 6 and 7 for a summary of which surface water constituents exceeded their established North Carolina Surface Water Quality Standards (NC2B)2 standard limits. Field parameters measured in the surface water included dissolved oxygen, pH, redox potential, specific conductance, turbidity, and temperature. The field parameter of turbidity was above its NC2B standards in three (3) locations. None of the other sampled field parameters were outside their NC213 standard limits for surface water, if established. 4.3 Leak Detectors and Leachate Samples The results of the leak detector field and laboratory analyses are summarized on Tables 8 and 9 and the laboratory analytical data is included in Appendix B. 'North Carolina Department of Environmental Quality, Classifications of Water Quality Standards, Section 15A NCAC 2L.0202, April 1, 2013. 2 North Carolina Department of Environmental Quality, Surface Waters and Wetlands Standards, Section 15A NCAC 02B workbook dated June 10, 2019. 2 of 3 1s 1m 1i Water Quality Report — 2nd Semi -Annual Event 2021 Buncombe County Landfill —Alexander, North Carolina March 7, 2022 BLE Project No. J21-9378-26 Please note that the NC2L standards shown on Tables 8 and 9 are for reference only. There is no regulatory standard for leak detectors or leachate. Field parameters measured in the leak detectors and leachate samples included pH, specific conductance, turbidity, and temperature. 5.0 CONCLUSIONS AND RECOMMENDATIONS Semi-annual assessment monitoring was performed during the 2" d semi-annual event of 2021 in general accordance with the approved WQMP and SWS approved sampling matrix (Table 1). Detected constituents which exceed their respective groundwater and surface water standards are identified on the summary tables. 6.0 QUALIFICATIONS OF REPORT The activities and evaluative approaches used in this assessment are consistent with those normally employed in hydrogeological and environmental assessments of this type. Our evaluation of site conditions has been based on our understanding of the site and project information and the data provided to BLE. This report has been prepared on behalf of and exclusively for the use of Buncombe County, North Carolina. This report and the findings contained herein shall not, in whole or in part, be used or relied upon by any other party (excluding the DWM) without BLE's prior written consent. 7.0 CLOSING We appreciate the opportunity to be of service to Buncombe County, North Carolina. Please contact us at (864) 288-1265 if you have any questions or comments. 3 of 3 TABLES Table 1 SWS Approved Sampling Matrix Buncombe County Landfill Alexander, North Carolina Permit No. 1107-CDLF-1998 Permit No. 1107-MSWLF-1996 BLE Project Number J21-9378-26 April October Station ID *Analytical Suite* 1,4-Dioxane *Analytical Suite* 1,4-Dioxane a MW-1 A-1 Plus A-1 Plus x � u Pa MW-ID A-1 Plus A-1 Plus MW-2 A-1 A-1 MW-21) A-1 A-1 MW-3R A-1 A-1 MW-4 A-1 yes A-1 yes MW-41) A-1 yes A-1 yes MW-5 A-1 A-1 MW-5D A-1 A-1 MW-6 A-1 A-1 MW-7 A-1 A-1 MW-8 A-1 A-1 MW-8D A-1 A-1 MW-10 A-1 yes A-1 yes MW-lOD A-1 yes A-1 yes MW-11 A-1 A-1 u e MW-11D A-1 A-1 UMW-12 A-1 Plus yes A-1 Plus yes MW-12D A-1 Plus yes A-1 Plus yes MW-13 A-1 A-1 MW-13D A-1 A-1 MW-14 A-1 Plus A-1 Plus MW-14D A-1 Plus A-1 Plus MW-15 W W MW-15D W W MW-16 A-1 yes A-1 yes MW-16D A-1 yes A-1 yes MW-17 Abandoned September 14, 2020 MW-17D Abandoned September 14, 2020 MW-17R A-1 Plus yes A-1 Plus yes MW-17DR A-1 Plus yes A-1 Plus yes MW-18 A-1 Plus yes A-1 Plus yes SW-1 A-1 yes A-1 yes SW-2 A-1 yes A-1 yes SW-3 A-1 yes A-1 yes d SW-4 A-1 yes A-1 yes o SW-5 A-1T yes A -IT yes SW-6 A-1T yes A -IT yes SW-7 A-1 yes A-1 yes SW-8 A-1T yes A -IT yes LD-1 A-1 A-1 i, LD-2 A-1 A-1 0 LD-3 A-1 A-1 Ca R LD-4 A-1 A-1 u �? LD-5 A-1 A-1 yes d R LD-6 A-1 A-1 u LD-7 A-1 A-1 .a Leachate LD A-1 A-1 Leachate Pond LMP LMP Notes: A-1 —Appendix I VOCs & Metals A -IT = Appendix I VOCs plus Tetrahydrofuran & Metals A-1 Plus = Appendix I VOCs plus Tetrahydrofuran, & Metals plus Mercury, Manganese, Iron, Sulfate, Chloride, Alkalinity, & Total Dissolved Solids LMP (Leachate Monitoring Parameters) = Appendix I VOCs & Metals, pH, specific conductance, BOD, COD, Nitrates, Sulfates, & Phosphates. W = Water Level Only LD = Leak Detector Does Not Exist - Pennitted for Future MSWLF Cell 7 1,4-Dioxane removed for these points Table revised July 16, 2019 (SW-8 and 1,4-doxane) Table revised February 27, 2020 (BLE Project No. 9378-20 for Spring 2020) Table revised June 19, 2020 (Change 1,4-Dioxane Matrix) Table revised October 14, 2020 (Abandon MW-17/MW-17D) Table revised July 20, 2021 (Remove MW-15/MW-15D & add MW-18) Prepared by: AWA Checked by: TJD S:\Buncombe County Active LF, NC\9378-26A FY22 Fall 2021 Report\04 Tables\9378-26 SWS Approved Matrix Table 2 Well Construction and Monitoring Well Data Buncombe County Landfill Alexander, North Carolina Permit No. 1107-CDLF-1998 Permit No. 1107-MSWLF-1996 BLE Project Number J21-9378-26 Monitoring Point MSW or C&D Latitude Longitude Northing' Easting' TOC Elevation (ft)' Ground Surface Elevation (ft)' Depth to GW (ft) October 25-26, 2021 Groundwater Elevation (ft) Well Depth (fit)' Screen Depth (below GS)' Waste Unit Monitored Installation Date' Geology Monitored' Well Status/Purpose Well Diameter (in)' MW-1 Facility 33.570245 -85.567196 737,383.3 923,481.5 2021.22 2019.28 64.70 1956.52 76 61.0 - 76.0 Facility 1990's Saprolite/PWR Background 2.0 MW-ID Facility 33.570242 -85.567236 737,371.0 923,468.7 2021.57 2019.97 66.21 1955.36 200 85.0 - 95.0 Facility 1990's Bedrock Background 2.0 MW-2 MSW 33.570284 -85.566586 739,569.6 921,033.3 1920.86 1918.54 8.52 1912.34 20 5.0 20.0 Cell 1990's Saprolite/PWR Compliance 2.0 MW-2D MSW 33.570283 -85.566599 739,565.7 921,027.7 1920.51 1918.63 8.73 1911.78 55 45.0 - 55.0 Cell 1990's Bedrock Compliance 2.0 MW-3R MSW 33.570271 -85.566817 739,499.1 920,384.3 1973.18 1975.67 54.94 1918.24 55 45.0 - 55.0 Cell 7/28/2014 PWR Compliance 2.0 MW-4 MSW 33.570228 -85.567590 739,263.0 920,192.1 1944.35 1942.48 12.95 1931.40 25 9.0 24.0 Cell 1011011996 Saprolite/PWR Compliance 2.0 MW-4D MSW 33.570228 -85.567597 739,261.0 920,177.3 1944.64 1942.79 14.27 1930.37 55 45.0 - 55.0 Cell 1011111996 Bedrock Compliance 2.0 MW-5 MSW 33.570201 -85.568087 739,111.5 920,246.7 1977.12 1975.39 33.96 1943.16 50 35.0 - 50.0 Cell 101911996 Saprolite/PWR Compliance 2.0 MW-5D MSW 33.570199 -85.568112 739,103.6 920,242.3 1976.92 1975.31 35.86 1941.06 81 71.0 - 81.0 Cell 1011011996 Bedrock Compliance 2.0 MW-6 MSW 33.570317 -85.565937 738,767.9 920,223.6 1987.34 1985.39 24.98 1962.36 50 35.0 - 50.0 Cell 101811996 Saprolite/PWR Compliance 2.0 MW-7 MSW 33.570230 -85.567514 738,286.3 920,586.8 2022.83 2020.72 44.99 1977.84 61 42.0 - 61.0 Cell 101411996 Saprolite/PWR Compliance 2.0 MW-8 MSW 33.570196 -85.568117 738,102.0 920,801.7 1962.06 1959.85 29.11 1932.95 70 55.0 - 70.0 Cell 1990's Saprolite/PWR Compliance 2.0 MW-8D MSW 33.570199 -85.568069 738,116.7 920,812.0 1962.47 1960.57 27.86 1934.61 95 85.0 - 95.0 Cell 1990's Bedrock Compliance 2.0 MW-10 MSW 33.570239 -85.567391 739,324.0 921,597.0 2010.54 2007.50 68.44 1942.10 73 58.0 - 73.0 Cell 3/6/2002 Saprolite/PWR Compliance 2.0 MW-10D MSW 33.570239 -85.567391 739,324.0 921,590.8 2010.56 2007.50 69.03 1941.53 117 102.0 - 117.0 Cell 3/6/2002 Bedrock Compliance 2.0 MW-11 MSW 33.570208 -85.567897 738,169.2 921,422.1 1966.71 1963.70 32.95 1933.76 50 35.0 - 50.0 Cell 3/6/2002 Bedrock Compliance 2.0 MW-11D MSW 33.570206 -85.567947 738,154.0 921,406.0 1966.15 1963.20 34.21 1931.94 70 60.0 - 70.0 Cell 3/6/2002 Bedrock Compliance 2.0 MW-12 C&D 33.570306 -85.566147 738,703.7 919,192.4 1947.39 1944.70 12.20 1935.19 17 7.0 17.0 Phases 1 - 5 6/25/2002 Saprolite/PWR/Bedrock Compliance 2.0 MW-12D C&D 33.570269 -85.566849 739,489.5 921,966.6 1947.10 1944.30 10.91 1936.19 37 27.0 - 37.0 Phases 1 - 5 6/25/2002 Bedrock Compliance 2.0 MW-13 MSW 33.570269 -85.566849 739,489.5 921,966.6 1953.92 1951.30 4.67 1949.25 16 6.0 16.0 Cell 612412005 Bedrock Compliance 2.0 MW-13D MSW 33.570316 -85.565957 738,761.6 919,055.7 1953.82 1951.40 7.36 1946.46 44 39.0 - 44.0 Cell 6/23/2005 Bedrock Compliance 2.0 MW-14 C&D 33.570320 -85.565889 738,782.5 919,037.1 1952.77 1949.80 29.85 1922.92 49 39.0 - 49.0 Phases 1 -5 4/5/2006 Bedrock Compliance 2.0 MW-14D C&D 33.570306 -85.566147 738,703.7 919,192.4 1953.76 1950.70 30.28 1923.48 88 78.0 - 88.0 Phases 1 - 5 4/6/2006 Bedrock Compliance 2.0 MW-15 C&D 33.570207 -85.567982 739,143.4 919,829.3 1973.29 1970.21 21.33 1951.96 26 16.0 - 26.0 Phases 1 - 5 6/7/2012 Saprolite/PWR WL 2.0 MW-15D C&D 33.570207 -85.567982 739,143.4 919,829.3 1973.51 1970.25 21.08 1952.43 43 33.0 - 43.0 Phases 1 - 5 6/7/2012 Bedrock WL 2.0 MW-17 Abandoned - September 14, 2020 MW-17D Abandoned - September 14, 2020 MW-17R C&D 33.570283 -85.566553 738,579.7 918,662.0 1891.61 1888.96 15.82 1875.79 23.5 8.5 23.5 Phase 6 9/3/2020 Bedrock Compliance 2.0 MW-17DR C&D 33.570281 -85.566586 738,569.7 918,659.3 1891.70 1889.14 14.21 1877.49 39 34.0 - 39.0 Phase 6 9/2/2020 Bedrock Compliance 2.0 MW-18 C&D 33.570214 -85.567851 739,183.2 919,705.2 1940.67 1937.97 44.75 1895.92 51.5 41.5 - 51.5 Phases 1 - 5 6/11/2008 Bedrock Compliance 2.0 ' - Data from Table 3, Well Construction, New Buncombe County Landfill, Buncombe County, North Carolina, provided by SCS Engineers. Z - Based on visual observation of Sheet No I Groundwater and Methane Monitoring Well Locations by CDM Smith dated August 2014. Some well installation dates appear inconsistent with water level records and may not be accurate. Changes to some dates (italics) made based on water level records and dates from SHR and DHR documents by CDM. The top of casing and ground surface elevations for MW-3R are a probable error (reversed) based on April 2016 water levels in the SCS Engineers report. The top of casing and ground surface elevations for MW-14 and MW-14D do not match those in the SHR and DHR documents by CDM. The well construction and survey data for MW-17R and MW-17DR are from a report by SCS dated October 13, 2020 Location accuracy of the monitoing wells is limited by the references themselves The well construction data for MW-18 are from the DHR table and boring log by CDM. Surveying was performed by Ed Holmes and Associates of Asheville, NC in September 2021. TOC - Top of Casing. GS - Ground Surface. WL - Water Level only All depth measurments in feet -- All elevations in feet above an arbitrary site datum 9378-26A GW Tables (Completion, water levels, detections) Prepared by: RLB T2 (10-26-21) MW Points Checked by: TAO/ AWA Table 3 Range of Groundwater Flow Velocities Buncombe County Landfill Alexander, North Carolina Permit No. 1107-CDLF-1998 Permit No. 1107-MSWLF-1996 BLE Project Number J21-9378-26 Hydraulic Conductivity K(ft/min) K(cm/sec) K(ft/day) High Estimate 8.0E-03 4.1E-03 11.500 Low Estimate 9.7E-05 4.9E-05 0.140 Geometric Mean 8.8E-04 4.5E-04 1.269 Geometric Mean Hydraulic Conductivity K(ft/day) Hydraulic Grad. (ft/ft) Effective Porosity Flow Vel. (ft/day) Flow Vel. (ft/year) High Estimate 1.269 0.286 5% 7.25 2647 Low Estimate 1.269 0.025 28% 0.12 42 Notes 1. Hydraulic conductivity and effeictive porosity values obtainted from Tables 5 and 6 of the Design Hydrogeologic Report - Phase 6 C&D prepared by BLE dated September 21, 2017. 3. The hydraulic gradients were measured from the October 25-26, 2021 groundwater elevation contour map (Figure 2). The high hydraulic gradient was measured between the 1880-ft & 1900-ft groundwater contours near MW-17R and MW-19. The low hydraulic gradient was measured between the 1950-ft & 1960-ft groundwater contours near MW-12. 4. Groundwater velocity derived from V = Ki/n, where: K = geometric mean hydraulic conductivity, i = hydraulic gradient, and n, = effective porosity. 5. The high and low velocity estimates are calculated using the geometric mean K and the high and low range of site hydraulic data obtained from BLE's 2017 DHR. 9378-26A GW Tables (Completion, water levels, detections) Prepared By: RLB Table 3 GW Flow Vel. Checked By: TAO/ AWA Table 4 Groundwater VOCs Buncombe County Landfill Alexander, North Carolina Permit No. 1107-CDLF-1998 Permit No. 1107-MSWLF-1996 BLE Project Number J21-9378-26 Sampled by Pace Analytical Services, LLC. October 26-28, 2021 TEST UNITS LOQ DL MCL MW-1 MW-11) MW-2 MW-21) MW-311 MW4 MW4D KW-5 MW-513 KW-6 MW-7 KW-8 MW-81) KW-10 MW-lOD MW-11 MW-11D MW-12 AM-12D MW-13 MW-13D MW-14 MW-14D MW-15 MW-15D MW-17R MW-17DR MW-18 EQUIP. BLANK Acetone µg" 20 5.0 6,000 15.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 8.1 JL <5.0 <5.0 <5.0 <5.0 <5.0 NS NS <5.0 <5.0 <5.0 <5.0 Acrylonitrile 99/1 20 0.80 NE <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 NS NS <0.8 <0.8 <0.8 <0.8 Benzene µg" 1.0 0.40 1.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Bromochlommethane 99/1 1.0 0.40 NE <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Bromodichlommethane µg/1 1.0 0.40 0.6 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Bromoform µg/1 1.0 0.40 4.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Carbon Disulfide µg/1 1.0 0.40 700 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 1 <0.4 <0.4 <0.4 Bromomethane (Methylbromide) 99/1 2.0 0.40 10.0 (i) <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Carbon tetrachloride µg" 1.0 0.40 0.3 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1 <0.4 1 <0.4 <0.4 1 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Chlorobenzene (mono) µg/l 1.0 0.40 50.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Chloroethane 99/1 2.0 0.40 3,000 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Chloroform µg/1 1.0 0.40 70.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Chloromethane (Methylchloride) µg/1 1.0 0.50 3.0 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 NS NS <0.5 <0.5 <0.5 <0.5 Dibromochloromethane µg/1 1.0 0.40 0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 1,2-Dibromo-3-chloropropane; DBCP µg/1 1.0 0.40 0.04 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 1,2-Drbromoethane; Ethylene dibromide µg" 1.0 0.40 0.02 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 1 <0.4 <0.4 <0.4 Dibromomethane µg/1 1.0 0.40 70.0 (i) <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 112-Dichlorobenzene 99/1 1.0 0.40 20.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 1,4-Dichlorobenzene 99/1 1.0 0.40 6.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1 <0.4 1 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 trans-1,4-Dichloro-2-butene 99/1 2.0 0.50 NE <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 NS NS <0.5 <0.5 <0.5 <0.5 1,1-Dichloroethane 99/1 1.0 0.40 6.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 0.84 J <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 1,2-Dichloroethane µg/1 1.0 0.40 0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 10.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 1, 1-Dichloroethene (-ethylene) µg/1 1.0 0.40 350.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 cis-1,2-DicNoroethene (-ethylene) µg" 1.0 0.40 70.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 0.47 J <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 trans-1,2-Dichloroethene (-ylene) µg" 1.0 0.40 100 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1 <0.4 <0.4 <0.4 <0.4 1 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 1 <0.4 <0.4 <0.4 1,2-Dichloropropane 99/1 1.0 0.40 0.6 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 cis-1,3-Dichlmopropene (-propylene) 99/1 1.0 0.40 0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 trans-1,3-Dichloropropene (-propylene) 99/1 1.0 0.40 0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Ethylbenzene µg/1 1.0 0.40 600 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 2-Hexanone 99/1 10 2.0 40.0 (1) <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 NS NS <2.0 <2.0 <2.0 <2.0 Iodomethane 99/1 5.0 0.40 NE <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Dichloromethane (Methylene chloride) µg" 1.0 0.40 5.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 2-Butanone (Methyl ethyl ketone) µg" 10 2.0 4,000 <2.0 2.3 J <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 NS NS <2.0 <2.0 <2.0 <2.0 4-Methyl-2-Pentanone µg/l 10 2.0 NE <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 NS NS <2.0 <2.0 <2.0 <2.0 Styrene 99/1 1.0 0.41 70.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 1, 1, 1,2-Tetrachloroethane 99/1 1.0 0.40 1.0(i) <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 1, 1,2,2-Tetrachloroethane 99/1 1.0 0.40 0.2 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Tetrachlomethene (-ethylene) 99/1 1.0 0.40 0.7 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Toluene µg" 1.0 0.40 600 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 1, 1, 1 -Trichloroethane 99/1 1.0 0.40 200 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 1,1,2-Trichloroethane 99/1 1.0 0.40 0.6(i) <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Trichloroethene (-ethylene) 99/1 1.0 0.40 3.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Trichlorofluoromethane µg/l 1.0 0.40 2,000 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 1,2,3-Trichloropropane µg/1 1.0 0.40 0.005 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Vinyl acetate 99/1 5.0 1.2 88.0 (1) <1.2 <12 <1.2 <12 <1.2 <1.2 <1.2 <12 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 NS NS <1.2 <1.2 <1.2 <1.2 Vinyl chloride µg/1 1.0 0.40 0.03 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Total Xylenes 99/1 1.0 0.40 500 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 0.51 J <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 NS NS <0.4 <0.4 <0.4 <0.4 Tetrahydrofuran µg/1 5.0 1.0 2,000 (1) <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 3.4 J <1.0 <1.0 <1.0 <1.0 <1.0 NS NS <1.0 <1.0 <1.0 <1.0 1,4-Dioxane µ 1 3.0 1.0 3.0 NT NT NT NT NT <1.0 <1.0 NT NT NT NT NT NT <1.0 <1.0 NT NT 2.8 J 1.9 J NT NT NT NT NS NS <1.0 I <1.0 I <1.0 <1.0 Notes: 1. MCL = Maximum Contaminant Level, as established in the NCDENR, Classifications of Water Quality Standards Applicable to Groundwaters of North Carolina, Section 15A NCAC 21, .0202. Amended Eff. April 1, 2013 2. (i) = Interim Maximum Allowable Concentrations (IMACs). Updated June 30, 2021 3. Shaded cells indicate exceedances of IMACs 4. Shaded cells indicated exceedances of MCLs 5. NE = Not Established; North Carolina has not established a MCL 6. LOQ = Limit of Quantitation 7. DL = method Detection Limit 8. NT = Not Tested 9. NS = Not Sampled 10. "J"-flagged data (i.e., values estimated between the DL and the LOQ) are presented on this spreadsheet. 11. "L" flagged data denote LCS/LCSD failure 9378-26A GW Tables (Completion, water levels, detections) Prepared by: RLB T4 (10-28-21) VOC Checked by: TAO/ AWA Table 5 Groundwater Field Parameters, Geochemical Parameters, and Total Metals Buncombe County Landfill Alexander, North Carolina Permit No. 1107-CDLF-1998 Permit No. 1107-MSWLF-1996 BLE Project Number J21-9378-26 Sampled by Pace Analytical Services, LLC. October 26-28, 2021 TEST UNITS LOQ DL MCL MW-1 MW-1D MW-2 MW-2D MW-3R MW-4 MW-4D MW-5 MW-5D MW-6 MW-7 MW-8 MW-8D MW-10 MW-10D MW-11 MW-11D MW-12 MW-12D MW-13 MW-13D MW-14 MW-14D MW-15 MW-15D MW-17R MW-17DR MW-18 EQUIP. BLANK pH S.U. <6.5; >8.5 6.4 7.5 6.3 6.6 6.1 6.3 6.7 6.3 6.3 6.1 6.4 6.5 6.3 6.1 6.5 6.6 6.7 6.3 6.8 6.5 6.3 6.2 7.3 NS NS 6.5 7.2 6.7 NT Specific Conductance µmhos/cm NE 180.1 280.1 449.8 262.1 96.7 237.7 306.9 224.1 216.7 144.5 694.0 388.2 440.7 333.8 361.2 458.4 444.0 965 470.7 469.3 423.7 179.1 332.1 NS NS 215.9 276.7 214.2 NT Temperature °C NE 12.9 10.5 14.2 13.8 17.3 15.4 14.7 17.9 16.1 13.8 16.2 13.8 14.1 13.2 15.7 13.0 14.8 19.0 17.1 15.8 14.9 14.2 13.5 NS NS 10.8 10.5 15.7 NT Turbidity NTU NE 9.7 9.8 7.3 3.1 6.9 1.0 1.3 8.3 3.2 3.2 9.0 5.4 2.4 3.7 4.2 8.6 5.4 1.7 3.4 3.2 2.2 8.4 2.4 NS NS 5.2 0.5 9.2 NT Alkalinity mg/i 20 20 NE 59 83 NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT 240 170 NT NT 65 140 NS NS 79 120 79 NT Total Dissolved Solids (TDS) mg/l 25 25 500 140 180 NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT 680 290 NT NT 140 210 NS NS 150 190 150 NT Iron H (Fe 2) µ 50 13 300 190 B 160 B NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT 130 B 290 B NT NT 150 B 240 B NS NS 290 200 300 NT Sulfate mg/l 1.0 0.25 250 20 41 NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT 290 66 NT NT 21 31 NS NS 33 25 30 NT Chloride mg/l 1.0 0.25 250 6.2 <0.3 NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT 38 12 NT NT 2.5 4.1 NS NS 3.2 3.9 1.7 NT Total Antimony (Sb) µg/I 2.0 0.5 1.0 (i) <0.5 0.66 J <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 1.6 J <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 NS NS <0.5 <0.5 <0.5 <0.5 Total Arsenic (As) µg/1 2.0 1.3 10.0 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 NS NS <1.3 <1.3 <1.3 <1.3 Total Barium (Ba) µg/I 5.0 1.3 700 140 31 76 48 64 40 110 130 74 50 180 140 170 140 30 64 64 110 63 200 230 50 8.0 NS NS 64 51 12 <1.3 Total Beryllium (Be) µg/1 0.4 0.15 4.0 (i) <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 NS NS <0.2 <0.2 <0.2 <0.2 Total Cadmium (Cd) µgfl 0.5 0.13 2.0 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 0.40 J <0.1 <0.1 <0.1 <0.1 <0.1 NS NS <0.1 <0.1 <0.1 <0.1 Total Chromium (Cr) µg/1 5.0 1.3 10.0 2.3 J <1.3 <1.3 <1.3 3.0 J 9.6 1.4 J 5.7 5.3 <1.3 2.7 J 2.7 J 1.4 J 3.9 J 3.8 J <1.3 <1.3 1.5 J <1.3 <1.3 <1.3 <1.3 <1.3 NS NS <1.3 <1.3 5.4 <1.3 Total Cobalt (Co) µg/I 5.0 1.3 1.0 (i) <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 11 <1.3 <1.3 <1.3 1.8 J <1.3 <1.3 3.3 J <1.3 <1.3 <1.3 29 2.1 J 26 21 <1.3 <1.3 NS NS <1.3 <1.3 <1.3 <1.3 Total Copper (Cu) µg/1 5.0 1.3 11000 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 3.2 J <1.3 <1.3 <1.3 <1.3 1.7 J <1.3 <1.3 <1.3 6.9 <1.3 19 <1.3 <1.3 <1.3 <1.3 <1.3 NS NS 7.0 <1.3 1.4 J <1.3 Total Lead (Ph) µgfl 1.0 0.25 15.0 <0.3 0.37 J <0.3 <0.3 <0.3 <0.3 0.46 J 0.33 J <0.3 <0.3 <0.3 0.26 J <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 0.26 J <0.3 <0.3 0.39 J NS NS <0.3 <0.3 <0.3 <0.3 Total Manganese (Mn) µg/1 5.0 1.3 50.0 7.5 14 NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT 2,500 470 NT NT 4.0 J 31 NS NS 8.8 24 NT Total Mercury (Hg) µg/I 0.20 0.091 1.0 <0.1 <0.1 NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT 0.23 <0.1 NT NT <0.1 <0.1 NS NS <0.1 <0.1 <0.1 NT Total Nickel (Ni) 119/1 5.0 1.3 100 2.7 J 4.5 J 5.7 <1.3 3.1 J 7.8 34 8.7 5.5 <1.3 15 3.1 J 4.3 J 11 12 22 <1.3 34 3.6 J 6.3 9.6 2.8 J <1.3 NS NS 22 <1.3 3.7 J <1.3 Total Selenium (Se) µg/I 5.0 1.3 20.0 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 NS NS <1.3 <1.3 <1.3 <1.3 Total Silver (Ag) µg/1 1.0 0.25 20.0 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 NS NS <0.3 <0.3 <0.3 <0.3 Total Thallium (TI) µgfl 0.5 0.15 0.2 (i) <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 <0.2 NS NS <0.2 <0.2 <0.2 <0.2 Total Vanadium (V) µg/1 5.0 2.5 0.3 (1) 3.7 J <2.5 2.8 J 3.2 J 4.3 J <2.5 <2.5 2.8 J <2.5 <2.5 <2.5 <2.5 <2.5 2.6 J <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 NS NS <2.5 <2.5 <2.5 <2.5 Total Zinc (Zn) ggf, 10 2.5 1,000 7.5J 5.5J <2.5 <2.5 5.9J 7.7J 14 5.1BJ 2.9J 3.0BJ 3.7J 16 4.7J 4.6J <2.5 8.7J <2.5 6.4J <2.5 9.8J <2.5 <2.5 8.8J NS NS 9.0J <2.5 3.6J <2.5 Notes: 1. MCL = Maximum Contaminant Level, as established in the NCDENR, Classifications of Water Quality Standards Applicable to Groundwaters of North Carolina, Section 15A NCAC 2L .0202. Amended Eff. April 1, 2013 2. (i) = Interim Maximum Allowable Concentrations (IMACs). Updated July 30, 2021 3. Shaded cells indicate exceedances of IMACs 4. Shaded cells indicated exceedances of MCLs 5. NE = Not Established; North Carolina has not established a MCL 6. LOQ = Limit of Quanfitation 7. DL = method Detection Limit 8. NT = Not Tested 9. NS = Not Sampled 10. "J"-flagged data (i.e., values estimated between the DL and the LOQ) are presented on this spreadsheet. 11. 'B"-flagged data (i.e., constituents detected in the method blank) are presented on this spreadsheet. 9378-26A GW Tables (Completion, water levels, detections) Prepared by: RLB T5 (10-28-21) Metals Checked by: TAO/ AWA Table 6 Surface Water VOCs Buncombe County Landfill Alexander, North Carolina Permit No. 1107-CDLF-1998 Permit No. 1107-MSWLF-1996 BLE Project Number J21-9378-26 Sampled by Pace Analytical Services, LLC. October 26-28, 2021 TEST UNITS LOQ DL NC2B SW-1 SW-2 SW-3 SW4 SW-5 SW-6 SW-7 SW-8 Acetone µg/l 20 5.0 2,000 <5.0 <5.0 9.7 JL <5.0 <5.0 <5.0 Dry <5.0 Acrylonitrile AgIl 20 0.8 420 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 Dry <0.8 Benzene µg/l 1.0 0.4 51 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 Bromochloromethane AgIl 1.0 0.4 NE <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 Bromodichloromethane 99/1 1.0 0.4 NE <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 Bromoform AgIl 1.0 0.4 120 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 Carbon Disulfide µg/l 1.0 0.4 100 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 Bromomethane (Methylbromide) µg/l 2.0 0.4 0.04 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 Carbontetrachlon µg/l 1.0 0.4 1.6 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 Chlorobenzene (mono) AgIl 1.0 0.4 800 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 Chloroethane µg/l 2.0 0.4 NE <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 Chloroform µg/l 1.0 0.4 2,000 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 Chloromethane (Methylchloride) µg/l 1.0 0.5 96 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 Dry <0.5 Dibromochloromethane AgIl 1.0 0.4 21 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 1,2-Dibromo-3-chloropropane; DBCP µg/l 1.0 0.4 0.13 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 1,2-Dibromoethane; Ethylene dibromide AgIl 1.0 0.4 0.1 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 Dibromomethane µg/l 1.0 0.4 NE <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 1,2-Dichlorobenzene AgIl 1.0 0.4 3,000 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 1,4-Dichlorobenzene µg/l 1.0 0.4 900 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 trans-1,4-Dichloro-2butene µ 2.0 0.5 NE <0,5 <0.5 <0,5 <0.5 <0.5 <0.5 Dry <0.5 l,l-Dichloroethane µg/l 1.0 0.4 100 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 1,2-Dichloroethane AgIl 1.0 0.4 650 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 l,l-Dichloroethene(-ethylene) 99/1 1.0 0.4 20,000 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 cis-1,2-Dichloroethene (-ethylene) AgIl 1.0 0.4 720 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 trans-1,2-Dichloroethene (-ylene) µg/l 1.0 0.4 4,000 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 1,2-Dichloro ro ane AgIl 1.0 0.4 31 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 cis-1,3-Dichloropropene (-propylene) µg/l 1.0 0.4 NE <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 trans-1,3-Dichloro roene (-propylene) As/, 1.0 0.4 NE <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 Ethylbenzene µg/l 1.0 0.4 97 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 2-Hexanone AgIl 10 2.0 NE <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 Dry <2.0 lodomethane µg/l 5.0 0.4 NE <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 Dichloromethane (Methylene chloride) As/, 1.0 0.4 11000 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 2-Butanone (Methyl ethyl ketone) µg/l 10 2.0 26,000 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 Dry <2.0 4-Meth-2-Pentanone AgIl 10 2.0 26000 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 Dry <2.0 Styrene µg/l 1.0 0.41 NE <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 1, 1, 1,2-Tetrachloroedme AgIl 1.0 0.4 NE <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 1, 1,2,2-Tetrachloroethane µg/l 1.0 0.4 4.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 Tetrachloroethene (-ethylene) µgFl 1.0 0.4 3.3 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 Toluene µg/l 1.0 0.4 11 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 1,1,1-Trichloroethane AgIl 1.0 0.4 200,000 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 1,1,2-Trichloroethane µg/l 1.0 0.4 8.9 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 Trichlomethene (-ethylene) AgIl 1.0 0.4 30 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 Trichlorofluoromethane µg/l 1.0 0.4 67,000 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 1,2,3-Trichloro ro ane AgIl 1.0 0.4 0.001 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 Vinyl acetate µg/l 5.0 1.2 NE <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 Dry <1.2 Vinyl chloride µ911 1.0 0.4 2.4 <0,4 <0.4 <0,4 <0.4 <0.4 <0.4 Dry <0.4 Total Xylenes µg/l 1.0 0.4 670 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dry <0.4 Tetrahydrofuran AgIl 5.0 1.0 110,000 NT NT NT NT 1.5 J <1.0 NT <1.0 1,4-Dioxane AgIl 3.0 1.0 80 <1.0 <1.0 15 <1.0 8.0 <1.0 Dry <1.0 Noter• 1. NC2B = North Carolina Surface Water Standards for Class C freshwater under Title 15A Subchapter 2B. per NC DWR Surface Water Quality Standards, Criteria, & In -Stream Target Values (Workbook Dated 6-10-2019) 2. NE = Not Established; North Carolina has not established a MCL 3. "J"-flagged data (i.e., values estimated between the DL and the LOQ) are presented on this spreadsheet. 4. Shaded cells indicated exceedances ofMCLs 5. LOQ = Limit of Quantitation 6. DL = method Detection Limit 7. NT = Not Tested 8. DNA = Data Not Available 9. "L" flagged data denote LCS/LCSD failure 9378-26A SW Tables Prepared by: RLB T6 SW VOC (10-28-21) Checked by: TAO/ AWA Table 7 Surface Water Field Parameters and Total Metals Buncombe County Landfill Alexander, North Carolina Permit No. 1107-CDLF-1998 Permit No. 1107-MSWLF-1996 BLE Project Number J21-9378-26 Sampled by Pace Analytical Services, LLC. October 26-28, 2021 TEST UNITS LOQ DL NC2B SW-1 NC2B SW-2 NC2B SW-3 NC2B SW-4 NC2B SW-5 NCHI SW-6 NC2B SW-7 NC2B SW-8 PH .u. (ao-site) - . <6.0;>9.0 7 <6.0;>9.0 7.9 <6.0;>9.0 7.9 <6.0;>9.0 7.5 <6.0;>9.0 8.2 <6.0;>9.0 7.60 <6.0;>9.0 Dry <6.0;>9.0 7.9 Specific Conductance µ.hos/-(on-srte) - - NE 136.7 NE 167.2 NE 1,220 NE 305.6 NE 1,449 NE 184.3 NE Dry NE 181.7 Temperature -C (on-srte) - - 29.0 12.2 29.0 10A 29.0 14.8 29.0 10 29.0 10.8 29.0 14A 29.0 Dry 29.0 11.1 Turbidity NTU (on-srte) - - 50.0 65.9 50.0 3.9 50.0 673 50.0 112.4 50.0 2.3 50.0 2.4 50.0 Dry 50.0 2.0 Hardness -Ad 10 2.0 NE NT NE NT NE NT NE NT NE NT NE NT NE Dry NE NT Total Antimany(Sb) Awl 2.0 0.5 5,300 <0.5 5,300 <0.5 5,300 <0.5 5,300 1.7J 5,300 <0.5 5,300 <0.5 5,300 Dry 5,300 <0.5 T-1 Arsenic (As) Awl 2.0 L3 10 <1.3 10 <1.3 10 <1.3 10 <1.3 10 <1.3 10 <1.3 10 Dry 10 <1.3 Total Barium (Ba) Awl 5.0 L3 21,000 130 21,000 53 21,000 190 21,000 130 21,000 190 21,000 100 21,000 Dry 21,000 52 T-1 Beryllium (Be) Awl 0.4 0.15 65 <0.2 65 <0.2 65 <0.2 65 <0.2 65 <0.2 65 <0.2 65 Dry 65 <0.2 Total Cadmium (Cd) Awl 0.5 0.13 0.79 <0.1 1.6 <0.1 3.67 <0.1 3.9 <0.1 16.86 <0.1 5.01 <0.1 52.31 Dry 4.57 <0.1 Total Chromtum(Cr) Awl 5.0 L3 177 1.4J 343.97 <1.3 750.54 2.3J 794.17 7.0 3,160.41 <1.3 1,005.17 <1.3 9,235.43 Dry 922.07 <1.3 Total Cobalt(Cal Awl 5.0 1.3 16 5.9 16 <1.3 16 7.7 16 5.4 16 12 16 <1.3 16 Dry 16 <1.3 Total Copper (Cu) Awl 5.0 1.3 3.5 64 7.52 <1.3 18.45 4.1 J 19.69 5.8 96.46 <1.3 25.82 <1.3 331.22 Dry 23.38 <1.3 Total Lead (Pb) µg/I 1.0 Q25 13.26 3.3 32.82 <0.3 92.97 0.90J 100.13 1.3 569A7 <0.3 136.14 <0.3 1,831.15 Dry 121.7 <0.3 Total alkkel(Ni) Awl 5.0 L3 140 <1.3 27&02 <1.3 622.43 19 659.84 8.0 2,748.17 24 941.66 <1.3 8,319.73 Dry 769.88 <1.3 TAW Selenium (Se) Awl 5.0 L3 5.0 <1.3 5.0 <1.3 5.0 <1.3 5.0 <1.3 5.0 <1.3 5.0 <1.3 5.0 Dry 5.0 <1.3 Total Sit-(Ag) Awl 1.0 0.25 0.28 <0.3 1.11 <0.3 5.74 <0.3 6.46 <0.3 11T49 <0.3 10.6 <0.3 1,117.04 Dry 8.84 <0.3 Total Thallium (TI) Awl 0.5 0.15 NE <0.2 NE <0.2 NE <0.2 NE <0.2 NE <0.2 NE <0.2 NE Dry NE <0.2 Total Vanadium(M Awl 5.0 2.5 NE 3.1J NE <2.5 NE Q.5 NE 11 NE Q.5 NE <2.5 NE Dry NE <2.5 Total Zinc (7.) I 10 2.5 34.97 44 69.52 Q.5 155.84 13 B 165.22 19 689.63 8.6 J 210.82 Q.5 2,091.32 Dty 192.82 Q.5 Notes: 1. NC213 = NAdb Carolina Surface Water Standards for Class C t-h-ler under Title 15A Subchapter 2B. per NC DWR Surface Water Quahty Standards, Criteria, & hr-Stream Target Values (Workbook Dated 6.10-2019) Measured values of hardness were utilized to calculate an scnte standard a each surface water Imam for metals highlighted in green. Hardness values were reposed in Report of Water Quality Sampfiug and Analysis Ist Semi-Aauual Evaa12020 Buncombe County Landf11 Alexander, North C-1- prepared by BLE, dated 7uly 13, 2020. 2. NE = N. Established; North Carolina has not established a standard 3. "1"-flagged data (Le., values estimated b-en the DL and the LOQ) are presented on this spreadsheet. 4. Shaded ceUs indicated exceedances ofMCLa S. LOQ = Limit of Q-titalion 6. DL= method Detection L®it 7. NT =Nat Tested 8. DNA =Data Not Available 9. V' Bagged data denote LCS/LCSD failure 10. "B"-Bagged data (ie., constituents detected in the method blank) are presented en this spreadsheet. 9378-26A SW Tables Prepared by: RLB T6 SW Metals (10-28-21) Checked by: TAO/ AWA Table 8 Leak Detector and Leachate VOCs Buncombe County Landfill Alexander, North Carolina Permit No. 1107-CDLF-1998 Permit No. 1107-MSWLF-1996 BLE Project Number J21-9378-26 Sampled by Pace Analytical Services, LLC. October 28, 2021 TEST UNITS LOQ DL MCL LD-1 LD-2 LD-3 LD4 LD-5 LD-6 Leachate LD Leachate Pond Acetone µg/l 20 5.0 6,000 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 80 JL Acrylonitrile µg/I 20 0.8 NE <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 <0.8 Benzene µg/l 1.0 0.4 1.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Bromochlororrt µg/I 1.0 0.4 NE <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Bromodichloromethane µg/l 1.0 0.4 0.6 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Bromoform µg/I 1.0 0.4 4.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Carbon Disulfide µg/l 1.0 0.4 700 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Bromomethane (Methylbromide) µg/I 2.0 0.4 10.0 0) <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Carbon tetrachloride µg/l 1.0 0.4 0.3 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Chlorobenzene (mono) µg/I 1.0 0.4 50 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Chloroethane µg/l 2.0 0.4 3,000 0.91 J <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Chloroform µg/I 1.0 0.4 70.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Chloromethane (Methylchloride) µg/l 1.0 0.5 3.0 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 Dibromochloromethane µg/I 1.0 0.4 NE <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1,2-Dibromo-3-chlompropane; DBCP µg/l 1.0 0.4 0.04 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1,2-Dibromoethane; Ethylene dibromide µg/I 1.0 0.4 0.02 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dibromomethame µg/l 1.0 0.4 70.0 (i) <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1,2-Dichlorobenzene µg/I 1.0 0.4 20 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1,4-Dichlorobenzene µg/l 1.0 0.4 6.0 0.46 J <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 trans-1,4-Dichloro-2butene µg/I 2.0 0.5 NE <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 1,1-Dichloroethane µg/l 1.0 0.4 6.0 0.59 J 1.2 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1,2-Dichloroethane µg/I 1.0 0.4 0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1,1-Dichloroetheme (-ethylene) µg/l 1.0 0.4 7.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 cis-1,2-Dichloroethene (-ethylene) µg/I 1.0 0.4 70 <0.4 0.45 J <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 trans-1,2-Dichloroetheme (-ylene) µg/l 1.0 0.4 100 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1,2-Dichloropropane µg/I 1.0 0.4 0.6 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 cis-1,3-Dichloropropene (-propylene) µg/l 1.0 0.4 0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 trans-1,3-Dichloropropene (-propylene) µg/I 1.0 0.4 0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Ethylbenzene µg/l 1.0 0.4 600 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 2-Hexanone µg/I 10 2.0 40.0 (i) 1 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 Iodomethane µg/l 5.0 0.4 NE <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Dichloromethane (Methylene chloride) µg/I 1.0 0.4 5.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 2-Butanone (Methyl ethyl ketone) µg/l 10 2.0 4,000 28 H <2.0 <2.0 <2.0 4.0 J <2.0 <2.0 25 J 4-Methyl-2-Pentanone µg/I 10 2.0 NE <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 Styrene µg/l 1.0 0.41 70 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 1,1,1,2-Tetrachloroethane µg/I 1.0 0.4 1.0 (i) <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1,1,2,2-Tetrachloroethane µg/l 1.0 0.4 NE <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Tetrachloroethene (-ethylene) µg/I 1.0 0.4 0.7 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Toluene µg/l 1.0 0.4 600 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1,1,1-Trichloroethane µg/I 1.0 0.4 200 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1,1,2-Trichloroethane µg/l 1.0 0.4 0.6 (i) 1 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Trichloroethene (-ethylene) µg/I 1.0 0.4 3.0 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Trichlorofluoromethane µg/l 1.0 0.4 2,000 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1,2,3-Trichloropropane µg/I 1.0 0.4 0.005 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 Vinyl acetate µg/l 5.0 1.2 88.0 (i) <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 Vinyl chloride µg/I 1.0 0.4 0.03 <0.4 <0.4 0.82 J <0.4 <0.4 <0.4 <0.4 <0.4 Total Xylenes µg/l 1.0 0.4 500 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 <0.4 1,4-Dioxane I 3.0 1.0 3.0 NT NT NT NT 1.6 J NT NT NT Notes; 1. MCL = Maximum Contaminant Level, as established in the NCDENR, Classifications of Water Quality Standards Applicable to Groundwaters of North Carolina, Section 15A NCAC 2L .0202. Amended Eff. April 1, 2013 2. (i)=Interim Maximum Allowable Concentrations (IMACs). Updated June 30, 2021 3. Shaded cells indicate exceedances of IMACs 4. Shaded cells indicated exceedances of MCLs 5. NE = Not Established; North Carolina has not established a MCL 6. LOQ = Limit of Quantitation 7. DL = method Detection Limit 8. NT -Not Tested 9. "J"-flagged data (i.e., values estimated between the DL and the LOQ) are presented on this spreadsheet. 10. "L" flagged data denote LCS/LCSD failure 11. "H" flagged data denote sample out of holding time 9378-26A Leachate Tables Prepared by: RLB T8 LD VOC (10-28-21)Checked by TAO/ AWA Table 9 Leak Detector and Leachate Field Parameters and Total Metals Buncombe County Landfill Alexander, North Carolina Permit No. 1107-CDLF-1998 Permit No. 1107-MSWLF-1996 BLE Project Number J21-9378-26 Sampled by Pace Analytical Services, LLC. October 28, 2021 TEST UNITS LOQ DL MCL LD-1 LD-2 LD-3 LD-4 LD-5 LD-6 Leachate LD Leachate Pond pH s.u. units (on -site) <6.5; >8.5 6.7 6.1 6.6 6.8 6.5 6.6 4.9 8.1 Specific Conductance µmhos/cm (on -site) NE 3,613 426.1 658 3,516 762 624 435.1 740.2 Temperature °C (on -site) NE 13.7 16.7 15.2 16.0 17.8 16.8 15.8 15.0 Turbidity NTU (on -site) NE 44.2 53.8 40.9 4.2 10.0 9.0 2.4 40 Biologic Oxygen Demand (BOD) mg/1 2.0 - NE NT NT NT NT NT NT NT 49 Chemical Oxygen Demand (COD) mg/1 80 80 NE NT NT NT NT NT NT NT 1,100 Nitrates mg/1 0.5 0.13 10 NT NT NT NT NT NT NT <0.13 Sulfates mg/1 10 2.5 250 NT NT NT NT NT NT NT 17 Phosphates mg/1 0.05 0.02 NE NT NT NT NT NT NT NT 2.9 Total Antimony (Sb) µg/1 2.0 0.5 1.0 (i) <0.5 <0.5 <0.5 0.96 J <0.5 <0.5 <0.5 12 Total Arsenic (As) µg/1 2.0 1.3 10 <1.3 <1.3 <1.3 4.1 <1.3 <1.3 <1.3 39 Total Barium (Ba) µg/1 5.0 1.3 700 1,300 110 220 490 170 460 24 450 Total Beryllium (Be) µg/1 0.4 0.15 4.0 (i) <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 0.15 J <0.15 Total Cadmium (Cd) µg/1 0.5 0.13 2.0 <0.13 <0.13 <0.13 <0.13 <0.13 <0.13 <0.13 <0.13 Total Chromium (Cr) µg/1 5.0 1.3 10 1.6 J 3.2 J <1.3 290 <1.3 <1.3 <1.3 94 Total Cobalt (Co) µg/1 5.0 1.3 1.0 (i) 270 23 5.2 11 78 98 24 22 Total Copper (Cu) µg/1 5.0 1.3 1,000 <1.3 4.1 J <1.3 12 <1.3 <1.3 7.9 1.8 J Total Lead (Pb) µg/1 1.0 0.25 15.0 <0.25 0.98 J <0.25 <0.25 <0.25 <0.25 <0.25 0.54 J Total Mercury (Hg) µg/1 NT NT 1.0 NT NT NT NT NT NT NT NT Total Nickel (Ni) µg/1 5.0 1.3 100 60 25 2.4 J 89 21 4.4 J 210 89 Total Selenium (Se) µg/1 5.0 1.3 20 1.8 J <1.3 <1.3 1.6 J <1.3 <1.3 1.4 J 1.8 J Total Silver (Ag) µg/1 1.0 0.25 20 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 Total Thallium (Tl) µg/1 0.5 0.15 0.2 (i) <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 Total Vanadium (V) µg/1 5.0 2.5 0.3 (i) <2.5 4.8 J <2.5 17 <2.5 <2.5 <2.5 41 Total Zinc (Zn) µ /1 10 2.5 1,000 5.5 BJ 18 B <2.5 13 B 2.9 BJ 4.8 BJ 100 B 19 B Notes: 1. MCL = Maximum Contaminant Level, as established in the NCDENR, Classifications of Water Quality Standards Applicable to Groundwaters of North Carolina, Section 15A NCAC 2L .0202. Amended Eff. April 1, 2013 2. (i) = Interim Maximum Allowable Concentrations (IMACs). Updated June 30, 2021 3. Shaded cells indicate exceedances of IMACs 4. Shaded cells indicated exceedances of MCLs 5. NE = Not Established; North Carolina has not established a MCL 9378-26A Leachate Tables T9 LD Metals (10-28-21) 6. LOQ = Limit of Quantitation 7. DL = method Detection Limit 8. NT = Not Tested 9. "J" -flagged data (i.e., values estimated between the DL and the LOQ) are presented on this spreadsheet. 10. "B" -flagged data (constituent detected in the method blank) are presented on this spreadsheet. Prepared by: RLB Checked by: TAO/AWA FIGURES J o M � \ 1751 a 1745 �1 D R1PRW0DD � \l l w; I, $ N F ti ,s�J �1, - RTi Af �D 2\ 1 Alexander 2000 1000 0 2000 4000 APPROXIMATE SCALE IN FEET DRAWN: KLW DATE: 1-6-22 ' IM I BUNNELL � LAMMONS CHECKED: RLB CAD: BCLF26A-SLM ENGINEERING 6004 Ponders Court, Greenville, SC 29615 APPROVED: AWA JOB NO: J21-9378-26 Phone: (864) 288-1265 Fax: (864] 288-4430 REFERENCE: USGS TOPOGRAPHIC MAP, 7.5 MINUTE SERIES, LEICESTER AND WEAVERVILLE, N.C. QUADRANGLES, PHOTOREMSED 2017 AND PHOTOREMSED 2017. SITE LOCATION MAP I BUNCOMBE COUNTY LANDFILL ALEXANDER, NORTH CAROLINA FIGURE N N � CONVE IE CE CENTER LANDFILL OFFICE �93 QP��0�� �� BUILDING � F OO '007 it _.L �Sw 2 ,""_ WELL ` ` / j � � � M_� 1912,34 HOUSE — Mw-2 SW-6,- �/ Qe SCALE HOUSE MW-2D Q1 18 24 1911,78 PANTHER BRANCH *111t\ _� - ( -FLOW) 0 1 , ,� 1942.10 MW-10D MW-10 � /- LD 3 LU-4 1941,53 � MW-4 I -- -- -- ----t ` � .ice/ Q`— — — — — /� T �SW-8♦ MW-18 MW-4D21 /' V 1 i I 1895,92---1930,37 1 1941,06_ MW-SDI,. 1951.96 �MW-15 \SW_3 MW-5 1943.16 \ INACTIVE � = 1 INACTIVE _k" CELL 3 MW-15D '���_- \ - s 11 CELL 4 '` I 19 5 2, 4 3 I ..INACTIVE --------------- CELL 1 SW-5 � MW- 14 c o0 �� I I IIj cIII MW-17R a)1875,79T � MW-17DR1, 1877.49 I MW-CD 17D I04 MW-17 ® (AB) (AB) V '1922,92-MW-14DIK `®1923.48� / M � 1 � II �� M\ I � 19 1 � PERMITTEDPHAE � C&DSAREA � 000, L SW_7 MW-13 MW-13D)K 1949.25 1946,46 D 6 — 7-7 7,f I / / oe loe loe INACTIVE I CELL 2 INACTIVE CELL 5 �2•-r E _ �ACHATE � D �MW-8 _1932,95 �D MW-11 ��193] mw- MW-8D)K 1933.76 1934.61 EMPLOYEE E .EACHATE TRAILER E 'OND -� o 1000, 1 �, 1000, SW -4 / v 1 1 M-9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Tom♦ � F' FRENCH BROAD RIVER ♦n V MW-16MW-16D NOT NOT PRESENT PRESENT -------��----------------------�` � 1 PERMITTED FUTURE CELL 7 i ACTIVE CELL 6 / 04/ N CAR,oy NSF'�ti9 1 5 => �; w A�i,P,. M-8 1956.52 1960 MW-1 S MW-1D)K 1955,36 1950 REFERENCES: 1) SHEET NO. 1 GROUNDWATER AND METHANE MONITORING WELL LOCATIONS, CDM SMITH, PROJECT NO. 6447-105257. FILE: SITEMAP 2014.DWG. 2) SURFACE WATER LOCATIONS FROM SHEET NO. 1 GROUNDWATER AND METHANE MONITORING WELL LOCATION MAP, CDM SMITH, NOVEMBER 2012 PROJECT NO. 6447-93318. FILE: SITEMAP. DWG. 3) PHASE 6 C&D BOUNDARY PROVIDED BY MCGILL. 4) SHEET NO. OP-1 EXISTING CONDITIONS, CDM SMITH, PROJECT NO. 6447-97693. FILE: OP-1.DWG. 5) FIGURE NO. 3-1 WATER QUALITY MONITORING PLAN CELL 6 AREA, CDM, PROJECT NO. 6447, DATED NOVEMBER 2004. 6) SURVEY DATA FOR MW-17R, MW-17DR AND M-12R IN SCS REPORT DATED OCTOBER 13, 2020 7) SURVEYING FOR MW-18 PERFORMED BY ED HOLMES AND ASSOCIATES DATED SEPTEMBER 24, 2021 ,16111*� LOCATION ACCURACY OF THE FEATURES SHOWN IS LIMITED BY THE REFERENCES THEMSELVES. I0 i 1 go I� 01 �M tD � i j m m LEGEND —1980 TOPOGRAPHIC CONTOUR - - - - - WASTE UNIT BOUNDARY FACILITY BOUNDARY MW-10 EXISTING GROUNDWATER MONITORING WELL MW-16 PERMITTED FUTURE GROUNDWATER MONITORING WELL EXISTING SURFACE WATER SW-2 MONITORING LOCATION * LD-1 LEAK DETECTOR * LD-7 PERMITTED FUTURE LEAK DETECTOR 0 M-3 EXISTING LANDFILL GAS MONITORING WELL +M-5 PERMITTED FUTURE LANDFILL GAS MONITORING WE m EXISTING STRUCTURE MONITORED FOR LANDFILL GAS 1950 POTENTIOMETRIC ELEVATION CONTOUR (FEET MSL) CONTOUR INTERVAL = 10 FEET GROUNDWATER FLOW DIRECTION * DEEP WELL NOT USED FOR CONTOURING PURPOSES (AB) ABANDONED STREAM 200 100 0 200 400 APPROXIMATE SCALE IN FEET REVISIONS No. DESCRIPTION BY DRAWN: RLB CHECKED: TAO APPROVED: AWA DATE: 1-28-22 CAD FILE: BCLF 9378-26AWMT102621 JOB N0: J21-9378-26 IM BUNNELL � LAMMONS ENGINEERING 6004 Ponders Court, Greenville, SC 29615 Phone; (864) 288-1265 Fax; (864) 288-4430 GROUNDWATER ELEVATION CONTOUR MAP-OCTOBER 25-26, 2021 BUNCOMBE COUNTY LANDFILL ALEXANDER, NORTH CAROLINA FIGURE NO. 2 APPENDIX A FIELD SAMPLING LOGS PACE ANALYTICAL SERVICES, LLC. Dacun,nt Name: Field data Sheet D7 ument Number. F-CAR_F1.D_00,_,,,.03 Lk Name and Affiliation (Sampier(s): {� c, c e Name and Affiliation (Inspector): a Well Information WeII ID: VA W - I Well Diameter: Total Well Depth: U 3 ft Static Water Level•_ 7 U ft Height of Water Column; (q3 3 ft Well Locked: Project #' Bwh Id Data Sheet Review: Date: Iofletf?'l to ft o I, 1 construction: 40 /Steel/Stainless Steel) Multi Factor*:0' It �31'(Radius/12)2x3,14x7,481 Casing Volume: a �? gallons Cal. 3 Volumes;Z gallons By: `a view LF- Oct .Z( Pump inhke:______ 6,_________-ft Purge Information Date Purged: 10 / Z (o / 2 l start: 0 9 SO Plnish< 5 S Purge Rate: / 01 Purging / t Method: Y`ti 5 v�5o sti\ (7 $0 Total Volume Purged: 0 (g�lons ny (L) SamnlingInformation Date Collected; I o jZb/ 2-( Time Collected; // d ..r,�7/Pm) Sampling Equipment Used: �'x%'"LSo ry___ x C�"-��' Instrument ID: 3 TIOU 14. ,p 35S Bottle Type _ las I 25V K� OAS 3- Nu n,L via Field Measurements/Observatieus reservation U n or�,s 1'�CL y�Ana�lysis Required S vDC Sample Temp (°C): Diss Oxy Time., // 7 me; __Turbitiity(ntu): S 7 Time: U U (mg/4% ----------.____ , p Time; jj Do Fe 2+ mg/ L: D 0 Specific Cond. (uS): 1 5'0 ) .Time:. /% 1) D --------------__ Res. Cl(mg/L)/(ltg/L): T me: ___ "—'Inner sample pH (s.u.): _ �. y — _... _..._... Time: / ° O Odor: YW v� ________.__, ReDox (mv): t{�. U _ Tune: ly U --- �, Appearagce; eqr Time: -- ReDox (EH value):YSi ProPlus +200mV y�) d -----Time:�_ Other: //OC Genera 1/Weather Observations_ Time: k,.uiy/t ouny •ain.) Temp.. SD (°F) Wind & Sampler Signature;_ (mph) Date:. / O Z (, - ? i Time Temp, Diss Oxy. Spec• o ume Purged (aC) (rngj1) Cond. pI-I(s.u.) ReDox Turbidity remove, Water (u5) (mV) (ntu) (gallons/ 1 level (ft) Other 0955 I I y 7. 2 I Q6,5, (o, ro o21, o 1, k6 It Lf . Z /8L,8 (�. 6 z i. o /, I 0 6t%95 i 1000 0.3' 1It.3 7.o 18Y.5 6.5 a. /0.0 Gy9 6 y 96 I bl o , _W �,3 /frz.b G.5 �z.6 6, e Document Name: Document Issued: March g, 2019 any/ /a Field Data Sheet Pagel -of 1- ��' `l'a Document Number: Issueing Authority: F-CAR-FLD-001.rev.03 Pace Hunte�aville Quality Office I- E nf� I tI Location:.liS V'6�f A) Project: N£w Lr-Or'f Well ID: M W — ( Reviewed Date and By:_Is) ia.9 Iv (3n Stabffization Test 16 f1f(fU GTq dtrell.£?iaxss=ter hYwltapliaal3axFact�zs I 2:a�s 0-D'40B 2 tN.10 t1 �67'D 4 D ti530 1 <458D 2:�'i4iD Time Purged TemZI uCond. ( Spec. (u5) pH(s.u. )(j ReDox mV Turbidity (ntu) Volume Removed (gallons/�ni /L) circle one Water level Other (ft) (oZo (uZ5 103D 1035• t oLED (01(5 1050 b (o55 0.2 l�,o Q,1 tz.0 !,Z-0 1z.z. 12— /2.Z 1Z.6 G,`f G.5 To 7.1 ?,l 7.0 7., 7.1 7,o lgr.� tftl.G /Srl.z 179,G r79,7 IW,t [yo.z 17.7 179.7 1so, � G.s L, 5 G.5 4.5 415 G•4 G.`f 4,Y 6.4 y (., a9. /z.o 30.7 /o, 6 Z. /1,1 35.9 a.G.7 37.z /V, / Y0.6 / 3, 0 LFz,o (2-8 '`3.7 ,Z -z Y3.7 /z_z '15, ) .6 .1560 3000 35vo 5/ooc q,500 5000 5Soo o0o GSbo c ,9 6y9Y GY,9V 6%99 6Y,94� cv,Y Y, f/ �9 /:.��eeAnatylical i f ALE DOCument Name: BiLhl data Sheet. Dmument Number: F-CA1?-Fl..l)-00r-re¢o3 Nance and Affiliation (Sarnpler(s): C C6- --P4 c z Name and Affiliation (Inspector): Lk. 1 Well Information Well ID: M W — I Well Locked: Well Diameter: 1 '--------------_.. CollStruCEiOn? Total Well Depth: �' s S ft Static Water Level; �' G 2 1 {t Height of Water Column: I •3Ift Mc U Data Sheet Review Date: 10114 I t l NO / Flushmmint l / Steel) Multi Factor*: b - 16 3 1*(Radi1s/12)2.x 3:14 x Z481 Casing Volume; 5. 1 1 gallons Cal.3 Volumes; / s• �3 .gallons Pump Intake: i 5 . o Co. IJcw Lr- Oct zl —Iti By; c-xl3 Purge Information It Date Purged w/ 1(0 / 2 1 Start; (2q 0O q / Finish: � 1)-o PwrgeBate: Purging Method: YVL 'vx:5 0 f Total Volume Purged: Xy D (gaAons,�O/L) Sampling Information Q Date Collected; I u / X6/ zl Time Collected: - � / �5 (a/Pm) Sampling Equipment Used: $out Instrument1D; 5'G'it 0"3 (PcJ 03SS Bottle Type Preservation Analysis Required X50 4—AIL Field MeasurenxentslO ibservations— Sample Temp (°C): ) D , S Ttme; qq Turbidity (ntu): (i 00 Time: Diss Oxy (mg/L): % , z- Time: 0 `/ ZS Fe 2+ mg/L; /� J Time: Specific Cond. uS : a S D. 7 G 9L ( ) Time: Res. Cl (mglL)/(µg/L): '---Tune; ^ Sample pH(a,u): 7•-5 Time: Odor: __ -_____Time: 9z 5 ReDox (in --- ( ) — 3---- 5'_ Time: � �1 ZS Appearance: �.(�e ReDox (EH value):YSI ProPlus +20o,11V �Z 3 S. Other: Time: _ General/Weather Observations: O — Z6- z/ Time Pur urge, g Temp, ° (C) Diss Oxp. (mg/I) Spec Cond. Hsu p (� ) ReDox Turbidity Vo ume removed Water (US) (mv) (ntu) (gallons/©/ level (Jr Other b9o$ U, /z.o !, 3a7.7 (v.__ Lv,� o,I 3b G ,51 to /0.z 1. 3z7.7 6.a 6, 6 .� z,ll /o./ — G-5/ iS 1 v.3 1.3 z$%v 7.5 /D, z 90 /0,rf 1, z �C? . S 3�,g ,Ll 1 1zoo 1 $ 6-2.v2 ;1CBAn,7101Cftl. Document Name: Field data Sheet gate i Dmument Number: F-CAR-Fl..D_001-rev.03 Issuuig Autho: Client;z� Field Data Sheet Location: L l /� Project Name and Affiliation (Sampler(s): ,,' _1(1e ' Field Data Sheet Review; Name and Affiliation (Inspector):,//�j9 1 - z2. 2 i Well Information !�/z le! Date: / J/� �U 4Ve11 ID: /Yf l l/ Zy( Well Locked: ( S NO n n,, i Well Diameter: Z Total Well Depth: 2g3a Z 6 It Static Water Level• l� 15 S ft Height of Water Column: t y- 6 L ft Construction: Steel/Stainless steel) Multi Factor*: Q= /a NRadius/ia)z x 3.14 x 7.481 Casing Volume: 2` 39 gallons �I Cal. 3 Volumes; / gallons &L (L By` Ohd- Purge Information Pump Intake: 2�_ -- -ft DatePurged:10 _/ 3- / Z( Start: % Z30 Finish: )30 I urge Rate: Z�10��/ Purging Method:_Total Volume Purged:-. � Z -� �1 _ (gallons/[,) Sampling Information Date Collected: 11 t3 / 2a/ - I 'rime Collected; ).3 0 S Sampling Equipment Used: Li r lilt Instrument ID a%S//,�`I� /L/ Td v ..... Bottle Type Field Measurementalobservations Preservation Analysis Required Sample Temp (°C): ' I{ - l Time: 3 O S _.-_....---Turbidity (ntu): �, 3 Time: Diss Oxy (mg/L):_ 6,2 Time; Fe 2+ mg/ L:_ I r S Time: Specific Cond. (us): Time; Res. CI m L ( g/ )/(uB/L) Time: Sample pE[ (s u,): _ 6 3__. -Time: _ - on e -. _Time:.--. ReDox (mV): LiG 1 � Time: - — Appearance: deg.- Time: ReDox (EH value):YSI ProPlus +200mV i�_ timer: Ali/ General/Weather observations: Time u /cloudy/rainy) Tem/pJ._(dF) Wind 0`S (mph)Sampler Signature: Date: lO���/ �f- Stabilization Test Time Temp. Diss Ox . Spec. Vo ume Pur ed 0 1 y Cond. pH {s.u.) Ret?ox Turbidity removed Water g ( C) (11g/[,) (us) (mV) (ntu) (gallons/ems leveI(ft)FOthei za 71 Document Name: Fiehf data Shcet Date Issued: March 8; 2019 „r CCMkTIytiCaf Page:. 1 of Document Number: F-CAR-FLD-001-rev.03 Issuing Authority: Pace Huatersville Qual [y Office Name and Affiliation (Sampler(s) 'I y�qq� /L T: I / Field Data Sheet Review: Name and Affiliation (Inspector): Jf"1f m. (D Da . Z 2 _21 By: G L C Well Information 1p / 2 t ( y �z r Well ED: ! t / " o Well Lockett: ES5/ NO / Flushmaunt ) Well Diameter:_ Construction: (PVC Steel/Stainless Steel) Total Well Depth: 3 �f ft Multi Factor*: ' ( ( (Radius/12)2 x 3.14 x 7.481 Static Water level: J fkFi �� Casing Volume: J gallons Height of Water Column: g t"r�• �ft Cal.3 Volumes: _gallons Pump Intake, S G+ . ft Purge Information It - Date Purged:/�/ II(I Start : Finish; Purge Rater i Purging Method:_ �(� ri !< 7G( �J<, `C Total Volume Purged: t try/ o (gallons rails l,) Sampling Information Date Collected:f1l) /Z1/ r It Time Collected: �s (am p q Sampling Equipment Used! �Caf �>� C InstrumentID- 1,/S-� �� �%CyUrtp� Bottle Type Field Measurements/Obseryations Sample Temp (°C): a 3 Time:. Diss Oxy (mg/L): n Time: a, 1 Preservation Analysis Required _Lk 47/Se S �� Turbidity (ntu): _ 3• i Time: Fe 2+ mg/L:%��i Time: Specific Cond. (uS): ,r Time: Res. Cl (rng/L)/(pg/L): 'Time: Sample pFl(s,u,): v . .... _ - .Time: Odor:_._ //t� ----------Ttme:._-i' SC! / ReDox (mV): S Time: :a Appearance Fpq( 'Trine: ReDox (EH value):YSE ProPlus +200mV '7 Sr� Other: ,PVA Time: General/Weather Observations: (sou/cloudy/rainy) Temp. S `i (aF) Wind_(mph) Sampler Signature Stabilization Test 7 7PTimedTemp. (°C) Diss Oxy. (mg/L)1t Spec. ond. PH (s.u.) ReDox Turbidity- Vc ume removed Water Other ` (mV) (ntu) (gallons nil level (ft) L a D) 1 , 9S, J_ , , (0 I q q&2d1 L`o" CN-c e11i r Document Name: Field data Sheet Date //' ,�,�aceAnntyiicat r DMURIent Number: F-CAR-FLD-001-rev.03 Name and Affiliation (Samolerfsi: `P / G. 3aare.,,b�, ev. Ncw c.F- Uei al - Id Data. Sheet Review: Name and Affiliation (Inspector): 1'vov 2 j0iz(f2i C rx3 Well Information Date: By. i�ylt9lxl BnY WeII ID: Well Locked; YE / NO J Flushmount) Well Diameter: oZ y Construction:.- Q!2�YSfeet/Stainless Steel) Total Well Depth: $ � JQ� ft Multi Factor*: 0 " 1 3 r(LRadius/ lz)2 x 3.14 x 7.a81 Static Water Level 53• !a ft Casing Volume: 4 ' g 7 gallons Height of Water Column: S ' 1 ft Cal. 3 Volumes; °1' S Z gallons Pump Intake: 57' D ft Puree Information Date Purged: ( , / 5 J Zi Start: �'-oS Finish: Z 5 Purge Rate: co tl` Purging Method: Total Volume Purged: 3 0 0 D (gallons 16, 1 /L) Sampling information Date Collected: 1 D /A/ 7-( Time Collected; Sampling Equipment Used: l t cr0r . InstrumentID:YST 'f Ow3 'I—PW F(D,sS Bottle Type — 3 - 4 ttn,c. Field Measurenxents/Observations Preservation _ JCL Analysis Required Vo C- Sample Temp Cc): 3 Time:! .. Turbidity (ntu): (o' 1 Time: (Z'E O Diss Oxy (mg/L), �?` 0 Time: 12k� Fe 2+ mg/L: ---Time: / 1Y Specific Cond. (uS): 4 7 Time: t Ltr O Res. Cl (mg/L)/(µg/L): ` Time: Sample pH (s.u.): _, Ce' (_.-_-__.... Time: - t Z� 0 Odor: Time: z 4 U ReDox (mV): '3 Time; f 2K D — — Appearance: CD'ea r r',im, 12k u ReDox (EH value):YSI ProPlus +2OOmV 7H1 `+r • 3 Other: General/Weather Stabilization Test Time: � rainy) Temp. 7 -S (°'F) (u-zg— zI Time Purged Temp. CC) Diss Oxy. (mg/L) Spec. Cund • pH (s.u.) ReDox (mV) Turbidity (ntu) o time removed (gallons Water Other m / level (ft) (�- I D i5 . (a • 5 (,.3 -2V. L Soo Dkf l5,`f (.-S y,9 73 -a,y. )1, 3t3 i7-15 (0,0 6.3 87,13 Z �19, ato, a. /ova Sy.( 0 1 17.1 f2Z5 I 14•c" �.t 9q.'5 (Q.l U.j 11.9 zoao SY1 Document Name: Document issued: Much 8,2019 Field Data Sheet Pagel -of 7- issueing Authority; Document Number: F-CAR-FLD-001.rev.03 Pace Huntersville Quality Office AJ Location: (Z Project: 15 Well ID: Reviewed Date and BY: % '01 jIN pwo, Stabilization Test 1()f?q(7J Cm -1.2 1.625 2 WWW (gallons/@i/L)• circle one Ucxument Name: Field data Sheet Date Issued: March 8, 2t119 deefbkllytiCal Page: IOt [7c�cument Numliee F CAR-F[.I3-00brev.0.3 IssuingAuthority: Pace Huutersville Quality .._7 l Office Name and Affiliation (Sampler(s): C*'(-C' ` ha w Name and Affiliation (Inspector):tiR, Well Inforiation Weil ID: h"`^) Well Diameter: 2 Total Well Depth: a 5 • S'O ft Static Water Level: 13 • ( 0 Height of Water Column:! Z- 2- ft ^)C Project#:$k"�f Co. JU-7LF- 0'1 2.t- Sevv<,� Field Data Sheet Review: lw?z (211 CXi3 Date: By: )oJa9lzi 13rws Well Locked: 4IE3 / NO Construction://Sheet/Stainless Steel) Multi Factor*: 5 • (,63 ('(Radius/12)20.14 x.7,481 Casing Volume: . 9 9 gallons CaL 3 Volumes: 5 • 94 gallons Pump Intake: 23' C) ft Purse Information Date Purged: i 0 Start, (l y D Finish: � ( 5 5 Purge Rate: ) 6 D kvxL(t, _ Purging Method: S L 5'1 r. 1 [ r Total Volume Purged: 2-70 D (gallons/ ii /L) Sampling Information Date Collected: 1 0 / 7-1/ 'x I I I Time Collected; (tea o Sampling Equipment Used: s Tc L� c instrument ID: Y 52-# 0 Z-0-S -rPw A o355 Bottle Type Preservation 0CI- 7j - 1-to n..L Field Measurements/Observations Analysis Required - - - 5 ----- ---............. Voc Sample Temp (°C): 5 y Time: �_ ° Turbidity (ntu): / . 0 Time: J '2_0 0 Diss Oxy (mg/L): 1, D Time: / 2-Pa Fe 2+ mg/ L: /J Time: / ao 0 Specific Cond.(uS): a-3�•7 Time: /2o0 Res. Cl(tiig/L)/(ltg/L): � Time: Sample pH (s.u.): . 3 .__._.__Time: / 2P a Odor:_--. !A�.-._._-.._._ ReDox (mV): 3Y` (o Time: / z GD -f Appearance: t ter Time: /Zo ReDox (EH value):YSI ProPlus +20omV Other: — Time: General/Weather Observations: Sampler Signature Stabilization Test /rainy) Temp. S6 (°F) l v- L7- Spec. o unle Time Temp. Diss Oxy. Cond. pH (s.u.) ReDox Turbidity removed Water Other Purged ° (C) (mg/l.) (us) (inV) (ntu) (gallons/� Ievel (ft) L ll`I5 15.3 0.9 6.3 3`/.£ 2,0 700 13.G E st? 15 .3 0,9 ;Lq 6,3 3 Y. Q , 0 1 3.0 II§v L .5 (, o ;LY)1 ( 613 3V. / ), I �vo l 3.GI/ 1155 I ,-5-T 1.0 �39,0 l,.3 34• /. z� z7 no r1GeArh?iyl7Cal Document Name., Field data Sheet. Date Issued: March 8, 2019 Page:.Iof-1 i l�cicument Number: E-CAR-F[.D-007-rev.03 lssahig Authority: Pace Hunterwille Quality Office Name and Affiliation (Sampler(s): �'{ G " �q c e , Name and Affiliation (Inspector): L4ei Well Information Well ID: M -U- N Well Diameter: a tt Total Well Depth: 5,7• 9 Z Static Water Level: ) Li- 3 5 ft Height of Water Column:�f 3• 57ft Proje€t#:I�Iahconb� �.A)"i LF- 01'k 2J - sutif 1d Data Sheet Review: Date: 10 / 7,.^112a cz 10)79)21 By BNS Well Locked: (C( S� NO / Flushmount ). Construction: Q /,Steel/Stainless Steel) Multi Factor;0,/L3 madius/12)20.14xa.I81 Casing Volume: _�• 1y gallons CaL 3 Volumes: oZ I. 3 c' gallons Pump Intake: 55. 0 it PurgeInformation Date Pur Purged: 10 �i Zt Start: 1110 Finish: Purge Rate: g //L Purging Method: Total Volume Purged: / i b (gallonsQ/L) Sampling Information Date Collected: n / ollf ZI f/ )) Time Collected: / 3 (0/pm) Sampling Equipment Used:_fL41,sTc �T • C Instrument ]D: t 5`ZA,2 2.0 3 7 Pw #a3 sS Bottle Type - ) 3- Yo &�L Field Measurements/Observations Preservation ur_o,; H cC Analysis Required i7'lY �4!'S Vac Sample Temp CC): Time: -'__Turbidity (ntu): 3 Tillie: 1131, Diss Oxy (mg/L): O • 3 Time: /) 3 0 Fe 2+ mg/ L: /)'b Time: // 3 0 Specific Cond. (uS): 30(` g Time: /) 30 Res.CI(mg/L)/(gg/L), Time: Sample pH. (s.u.): to. ------- Time: /) 3 o Odor:_,_-. A ReDox (mV); 3 5. 5 Time: )/ 30 Appearance: /e5r Iime: 1l36 ReDox (EH value):YSI ProPlus +200mV = 3 5. 5 Other: - Time: — General/Weather Sampler Signature Stabilization Test Temp. 93 .("F) 0,7-7•z1 Time Temp. DissOxy' Spec. Coed. pH(s.u.) ReDox Turbidity o ume removed Water Other Purged (C) (mg/L) (US) (mV) (ntu) (gallons m s level (ft) L 111-5 )`% 39.2 3. Dttf /4.6 0.5 a96.1 G•V 3a.Z 3. pi, Le7 1 y. 1 0. `( 305.1 �. 36.7 /Yam 1 Y, Sl 0.3 307.0 („ 7 35A aa�o y. sY Document Name: Field data Sheet Date Issued: March 8, 2019: aEeNratyliCalx Page: I of 1 Document Number F-CAR-FLD-001-rcv.03 IssuAuthority: Pace Htmtersvilte Quality h,g y Offi€e Naive and Affiliation (Sam pler(s): /A -/A Name and Affiliation (Inspector): 'zm Well Information Well ID: /Ij✓- 5 Well Diameter: Total Well Depth: S ft a Static Water level: } ?l o "} ft Height of Water Column: 1'.- _ft Well Locked: Construction: C ild Data Sheet Review: Date: Steel) Multi Factor*: ["(Radius/12)2 x ,14 x 7.48] Casing Volume: 3 7 gallons Cal-3 Volumes; gallons Pumphitake: 'r50, S 'f ft Purge Information Date Purged: L6 (� f�Start: i�« Finish: 3J Purge Rate:i� Purging Method: A26 3ii l Total Volume Purged: 0 (gallons '/L,) Sampling Information Date Collected:— Time Collected:_. 5 !m Sampling Equipment Used: Instrument ID: Bottle Type Field Measurements/Observations Sample Temp (aC): _-1_7__q_Time:( Diss Oxy (mg/L): 0 Time: Specific Cond. (uS): 2 CI, Time: Sample pH. (s.u.): _ -- Time: ReDox (mV): L Tune: ReDox (EH value);YSI ProPlus +200mV_ Generalf Weather Observations: &� Sampler Signature Stabilization Test Preservation Analysis 1Required Turbidity (ntu): 9, 3 Tillie: ! D `� Fe 2+ mg/L: &Z10 Time: i) Res. Cl (mg/L)/(itg/L): — Time: �Y Odor:__.. 0 Time: _, ` 5 Appearance i5k�qf Y Time: Other: LA Timer rainy) Wind l'i-3� (mph) Spec. Volume Time Temp, Diss Oxy. Cond. pH (s.u.) ReDox Turbidity removed Water Other Purged (C) (mg/L) (US) (mV) (ntu) (gallons/�lls L level (ft) Jz i 0, .. c7G@MkT(yfiCa7 • l DocumentDate Name: Field data Sheet Issued: March 8, 2al Page: 1 of Document Number. fiCAR-FLI)-0Ol-rev.03 lssuuig Authority: Pace HimtersvilleQuality Office Name and Affiliation (Sampler(s): L' Wi e° c/( Name and Affiliation (Inspector): '4(A Well Information Well ID: AV-fi 0 Well Diameter: Total Well Depth: G� ft Static Water Level: ft Height of Water Column: et>. ,5 aft Well Locked: Construction: Ad Data. Sheet Review: Date: NO / Flushmount ) eel/Stainless Steel) l /{. Multi Factor`: 5, la('(fRadius/12)2 x 3.14 x 7,481 Casing Volume: 7 s �l gallons Cal.3 Volumes: gallons Pump Intake: % 7,> D ft BY:GcG- Purge Information I Date Purged:/ ( o= Start : I� Finish Y 5 1) Purge Rate: /,ice a fvf ) Purging Method:_ k� `i17o ra Total Volume Purged: l S o d (gallons/m--�f 1,) Sampling Information -7 Date Collected:/ / — Time Collected; ' 0 ._ (am/ ) Sampling Equipment Used: mjmsa"' Instrument ID: Bottle Type Field Measurements/Observations Sample Temp ('C): C& r t Time:. Diss Oxy (mg/L): iJ > Time: Specific Cond. (uS): ?—Time: Sample pH (s.u): _y am..... ... ... . Time: ReDox (mV): Time: Preservation Analysis Required ..�..-if<i ej Turbidity (ntu): c d Time: G0 Fe 2+ mg/L: IVIa)Time: Res. Cl (iitg/L)/(leg/L): —Time: Odor._--4// /?- ._ Time: _.. 0 Appearance (7!e(.'. t_ rime: ReDox (EH value):YSL I'roPlus+200iriV 'Z3 Z-/ Other: ✓V/ A Time. GeneraVWeather Observations: Temp. ( _(CF) Wind_I_5_(mph) Sampler Signature Stabilization Test Spec.kV)(n Volume Time Temp, Diss Oxy. pH (s.u.)(gallons removed Water Purged CC) (mg/L) (US) (uS)�`I�>> mis�Level (ft)Other i0Qv 1, C 0 .� �•�> . ,. 8F2l171rTlyilCRl Document Name: Field data Sheet Date Issued: March 8, 2P19. Page: lot [Jucument Number F-CAR-Fl..p-001-rev.0.1 Issuial; Authority: Pace Huntersville Qua Quality Y Office /,i- ad ,_-G"2.i Name and Affiliation (SampIer(s):...V44z664U, Name and Affiliation (Inspector): Well Information Well ID: /� 6-V -6 ' Well Locked: Well Diameter: �2 ,)'I Construction: Total Well Depth: 5C 'a It Static Water Level: �-5 r q £t Height of Water Column: al,% ft 1d Data Sheet Review: %o-Z2_zl Date6/x�/ By%3.0 s NO / Flushmount ) ael/Stainless Steel) Multi Factor*; O�// 3 r(R'a,dlus/i2)2x3,I4x7.881 Casing Volume: v� L gallons 1( Cal.3 Volumes: / .1 ( gallons Pump lnfake: r/ ', s ft Purge Information Date Purged J Z / �/ Staft:.:1500 Finish: Purge Rate: Purging Method;_ ���I I �j (� `` Total Volume Purged: " d (gallons] nlsIL) SamolinElnformation Date Collected: ) ti / 2tf 1-4 Time Colleeted:J 0- _ (am/ pi ) , Sampling Equipment Used: �Q/5' .,/f,o Instrument:1 Yam# 151/7r1 Xk 6ylxly.ter-L)p,fl /1 Bottle Type N�C/4) Preservation Analysts Required Field Measurements/Observations Sample Temp CC): 0 i Time:_ Diss Oxy (mg/L): r4. a Time: _ ��{ 5 Specific Cond. (uS): � Time: _ Sample pH (sm,); ReDox (mV): l Time: _ ReDox (EH value):YST ProPlus +200mV 2 nramuzarion iesr Turbidity (ntu): t, 1 Time: Fe 2+ mg/L:/.,mod Time: Res. CI (mg/L)/(µg/L): Tune: Odor. _Time:._. I' Appearance C •ea/ Time: Other: ,41zli Time Spec. Vo ume Time Teemp, Diss Ox Cond. pH (s.u.)6ReDoxTurbidity removed Water r Purged (C) (mg/I.) (uS) (ntu) (gallons/m(s/LlJi iip, 71 3 15 70 2c- BC/lik7(yl%Ca( t Document Name: Field data Sheet Date Issued: March 8, 2014: Page:. I of 1 Document Number F-CAR-FI..I}-001-rev.03 Issuing Authority Pace Huntersville Quality Office Le Name and Affiliation (Sampler(s): GLfr-�e Name and Affiliation (Inspector): Well Information Well ID: rA\-J - 7 Well Diameter: 2_ Total Well Depth: 5 s' L 2_ It Static Water Level: t( 31 A ft Height of Water Column: (�• 0- ft Sr Project#:&hc 'e Co. >JeW LF- bef,Z!- Field Data Sheet Review: Date: 1o12iru By: - hI1s11.1 RhS Well Locked: (YD/ NO / Flushmount ) Construction: &/Steel/Stainless Steel) Multi Factor*: 0 " 3 ("(Radiu9/12)2 x 314 x 7.48j Casing Volume: 5 5 gallons Cal.3 Volumes: 1, � 5 gallons Pump Intake. 66. s) ft Purge Information / Date Purged: 10 / Z r/ 2-1 Start; / 3 ZS Firtish: / 3115 Purge Rate: l o h/ �_ Purging Method: 1ti.8-h,So n y\ Total Volume Purged: °� ° , (gallons/ /71 /L) Sampling information Date Collected: 1 :7 / 2 k/ zl Time Collected: 3 S (am/j0m SamplingEquipment Use& M,tShSv0r InstrumentlD:5 '4G263 TPW io�sS Bottle Type J z50 ryt_ \0(ap 3-Ku wL Field Measurements/Observations Preservation WAfd3 - k(c c. Analysis Required -------------- Sample Temp (eC): �• Z- Time �3 5 D Turbidity (nhr) : ty [ • 0 Time: / 3 Digs Oxy (mg/L): 00' Time: / 3 5 U Fe 2+ mg/L: 50 Time. Specific Cond. (uS): '5/ L F / Time: / 3 5y Res. Cl (mg/L)/(ltg/L): — Time: Sample pH. (s.u.): ._._.._-Time: 3 SO Odor:—.... ReDox (mV): a�' `i Thne: 1 3 Se) Appearance: cl-e-tr Time: ReDox (EH value):YS1. ProPlus+2OOmV )Z7• `f Other: _ Time: General/Weather Sampler Signature Stabilization Test 10-z?-Z1 Spec volume Time Purged Teemp, (C) Digs Oxy. (mg/L) Cond. pH (s.u.) ReDox (mV) Turbidity (ntu) removed (gallonso/ Water level (ft) Other (US) L 133 15•9 L93 G•3 T1.a /3• Sb0 7 �taP Ig.9 0.(0 (, 3 .3 41/.z /3• — Y2• 1'V5 lL.o o.G (,13 G.3 33.S' /a.q /00v °i2. z. t34,� JT;�.5 I [09 (�. 30, o /o•vz.8/ l3t{5 lVz 0.5 1 Gq`I I G.y az.7 Yz•g i r..3 Document Name: Field data Sheet Date Issued: March 8, 2019 - 262A7k9/ytiCaf Page:. t oft Document Number. F-CAR-FL.17-001-rev.0:i Issuing Authority: Pace HtuuersvilleQuality ' t Office Name and Affiliation (Sampler(s) '-LQ - Name and Affiliation (Inspector): Well Inforinald Well ID: iP1 Ll $ Well Locked: Well Diameter: ,11 Construction: Project #: LZ/ Zv2l 1d Data Sheet Review: 10-Zi.ZI Date: By: By.�_ Steel) Total Well Depth: o� r ft Muhl PacYor* Ur [*(Radius/I2)2 x 3:14 x 7.g81 Static Water Level: d (t J ft ( Casnig Volume: gallons Height of Water Column: ��y.3 ft Cal, 3 volumes: gallons Pump Intake: zj - 4`-- ft Purge Inforniation Date Purged:—[/ .2 /_ Start s.�-b Finish: ( Purge Rate: �dn Purging Method:_ f %/ `l Total Volume Purged: 0 (gallonsJ nls 1.,) Samplin¢Ltformation Date Collected:-4C1_J�zJ-69�— - y_ Time Collected:_. 5 i y _ (amJ )y Sampling Equipment Used: I C t �( �J fQ l'7�(��!E�Y(�I., '1�i Instrument IA3 Bottle Type Field Measurements/Observations Preservation Analysis Required Sample Temp CC): _ � ^ 0 Time:-16_'!_'3 _Turbidity (ntu): s. ci Time: C_ Diss Oxy (mg/L): o Time: Fe 2+ mg/L: line: Specific Cond. (uS): Time: Res. Ct (mg/L)/(Itg/L):'Time: { Sant le H s.n. : c. 6 CI P p ( ) �.� -..._._....._Time: Odor:—,_��if%._..........._— Time: _. --..._ ReDox (m.V): '71, 9- Tune: l/ Appearance:. Time: ReDox (EH value):YSI ProPlus +200mV---a- , Other: s— Time: General/Weather Observations: Sampler Signature Stabilization Test Spec. Volume Time Temp. u Diss Oxy. Cond. pH (s.u.) ReDox Turbidity removed Water Other Purged (C) (mg/ uS) (mv) (ntu) (gallons mis level (ft) IMA ro/2 L y4 l q (o�1 330th p� 31 00 oo S�FG. C<�et /�,�/' Document Name: Field data Sheet Date Issued: March 8, 2D19 Page: I of nmument Number: F-CAR-FI S}-001-rev.03 Issuing Authority: Pace Huntersville Quality Office f/_„d'8C2Fh7f7/y(1CR( r Name and Affiliation (Sampler(s): lS/hj;ef7 —h Name and Affiliation (Inspector): Z � Well Information WeII ID: Any — 'e/J Well Diameter: Z� Total Well Depth: 97.q it Static Water Level; 2?. `3 ft Height of Water Column: 69- SO ft Well Locked: _Project#46 c e �c Ac e Gh Uef,ze)z/ %r AMh4 Id Data Sheet Review; Date: (Q-a'1-z1 By: Construction: (steel/Stainless Steel) Multi Factor: 0'163 [*(Radius/12)2 x 3.14 x 7.48] Casing Volume: f /. 33 gallons Cal. 3 Volumes: 33. 9 9 gallons Pump Intake: %s ft Pur a Information DatePurged:/O—/ 26 /Z/ Start:/6 � Finish: 6SS Purge Rate:47a-,,4, Purging Method/f Al G Total Volume Purged: � � O Z) (gallons/t�?L) Samvline Information Date Collected: /V _/ ZC/ el // / Time Colleetectj��t.__ (ant/ r� Sampling Equipment Used: i7e// �C Instrument Bottle Type Preservation nn pAnalysis Required ....\mt:.__.. 4R Field Measurements/Observatious Sample Temp (aC): I H' I Time: __110n _Turbidity (ntu): Time: 11cjv Diss Oxy (mg/L); ® , 5 Time: Fe 2+ mg/L; /Ue iJ , Time: Specific Cond. (uS): `ff)")% Time: Res.0 (mg/L)/(gg/L): Thrtei Sample pH(s.u,):_CJb__---- -Tine:_ Odor:_0one._.___„___�Tirne:._ ReDox(mV): 5"(J1 1 Tune: Appearance: Time: ReDox(EHvalue):YSIProP1us+200mV 2S�' + Other: 1/�/� Time: Generalf Weather Wind D_S (mph) Sampler Signature Stabilization Test Spec.ReDox Volume Time Temp. a Diss Oxy. Cond. pH (s.u.) Turbidity removed Water Other Purged (C) (mg/I,) (US) (mv) (ntu) (gallons/mQs/ level (ft) -7-64o L 10, 1 4u 6.3 5-o 3 Z_19 S �It .6 63 66;1 4, lcaqS I4. 0.-+S C,3 WI 1H 0 ZT 65o i� ftA3 G,_ Sl,'3.Q 51J)tT S S Jp�tvD Z� O T5- .. �iGBAItalyl%Ca1 i i Document Name Field data Sheet D,Xument Number: F-CAR-F1.D-001-Wv.03 rtela tiara Client: o, E Locaticm:�� Name and Affiliation (Sampler(s):�r Name and Affiliation (Inspector): Well Information Well ID: M W — i 0 Well Diameter: _ Total Well Depth: 6, L l ft Static Water Level:__G_,£t Height of Water Column. —I —.Aft ft Well Locked: Construction: !Id Data Sheet Review: ) o Date: f,0 _ 2Q _ �I vs+ l sw/ Nushmount) (heel/Stainless Steel) Multi Factor*: �6•� l*(Radius/ 12)2x 3: 14 x Z481 Casing Volume: t Z 7Z gallons Cal.3 Volumes; / gallons QVb By: C,(. C. Pump Intake:�_ft Purge Information Date Purged' /0 / 2$ Z / / Start:Finish:.l00s ' Purge PurgungMeEhod:�?PrFy2DaJoo Total Volume Purged:_I660 allons L Sampling Information Date Collected:/ Z / / Time Collected:— 10 l .___ ant ptn) Sampling Equipment Used: o va InsrrumentID: f/q 7y��S Bottle Type Field Measurement;/Observations Preservation /n1 PP-1 Required ._ APP-1 me -Jr i 110C__...__....._ Sample Temp (nC): 13.2 Time: 1010 _..__ Turbidi ntu : 3. �' ( ) Time: I 0 l O Diss Oxy (mg/L): 0 ,7 Time: Fe 2+ mg/L: So 5 Specific Cond. (uS): 333. d Time: Res.CI(pig/L)/(Rg/L): Time: Time: Sample pH {s.u.}: _ Fi• I ..____... Time: Odor:�lc,� Tune: --------_______ Tune: Appearance: clear Ti mme: ReDox (EH value):YSI ProPlus +200V 7-16.3 Other: yy General/WeatherOhservar; ,.�. Time Sampler Time Temp. Diss Oxy. Spec. Purged (uC) (mg/L) Cond. pH ('s.u.) (US) O So 13,4 i i 3531 I �� �- }3,2 LQ4� 3,2 a,q 33�,3 6, I oos _I�.2. o.°l 2zz Cl 1 ri fey/iamy) lemp.'Z_.(ar) Wind tj- e�(mph) ate: Vo uume ReDox Turbidity removed Water (mv) (iitu) (gaIlon ml Level (ft) Other }.6 s,L L s.g 3.6 60o GR,}S B/afh9/}/i!C'il Document Name: Field data Sheet J/ Document Number: F-CAR-171.D-001-rev.03 /YC Name and Affiliation J9/ ield Data Sheet Review: Name and Affiliation (Inspector)- Well Information Date: Welt ID: ZI ✓-100 s, i Well Lockett: NO / Ftushmount) Well Diameter: )�_ Construction: teel/Stainless Steel) Total Well Depth: J �j ft Multi Factor*; / ^, !' - G'�1J 1 f*(Radius/ 12)2x 3,1E x 7.481 Static Water LeveC C' I'' d _.____ft Casing Volume: '—fEr 2_ gallons Height of Water Column: S' 1a U 5 ft Cal. 3 Vglumes; / /to ' gallons Pure Information Pump Intake: ii fr3 r=_ft March ma's- G�C, o, By: Date Purged: c 1` Start V� l ?Finistr Purge urge Rate: f0U rr, 11 Purging Method:_ i'rp6o Total Volume Purged: r) r; O (1 (gallons. uil LJ SamD111, I Information Date Collected:_// Time Catlecteti:� r�tf an pin) Sampling Equipment Used: AN5�4 Instrument ID Battle Type Preservation Analysis Required Field Measurements/Observations Sample Temp (°C); !' Time::(%1:5.-__Turbidit nhz : e Y ( gI ) I _ y ( ) Tinxe: t l Diss Ox m L : i1. Time: Fe 2+ mg/L: () Time: Specific Cond. (uSJ: � lv f . Tizrre: �-'`----- y Res. Cl. (lrig/L)/(gg/L); 'Inner - Sample pH (s.u.); ._-...Tine: Odor:_ _ ReDax (mV); _ / 12 Time ------ ,.� _Time: Appearance: ReDox (EH value);YSI ProPlus +2p(rt7V I tme., Genera Other: /I✓ j Titne: t/4Veather Observatinns• tsunny45toudy rainy) Temp. f (°P) Wind f Sampler Signature: t�7.Gi./rG-' (mph) _Date: ( f/���/ate` Stabilz_______ anoTest n - Time Temp. Diss Oxy. Spec. Vo wine Purged (°C) (t11g/L) Cond. pH (s.u.) ReDox Turbidity removed Water (US) (mV) ("to) (gallons _' Other X nt) 6 �. h ��/ level (ft) Document Name: Docanient Issued: Mardi s, 2015 Field Data Sheet Page --�tif t. Document Number: Issuem Authority: F-CAR-Ff.D-001.rev.03 Pace Huntemville Quality Office /((� Client: �J�L (bell Diameter Multiplication Facto — 1 0.Ws �" Location:Zilejl;lfy AlL 1.2 0.0418 (( ProjecY.1crvG1c1�ti�1P if/ /',_ ���5,� _ C,!-��i�� `�/„2/�.�,..( 1.625 0.1030 ' 2 0.1630 WellID: AJI 1-4.)Q _ 3 0.3670 Reviewed Date and By: %fin%%f 4 -- 0.6530 Stabilization Test !° 2Q.2j CLCA 6 1.4680 3 2.6100 Time Temp, u Purged (C) piss Oxy. Spec. Cond. (mg/L) PH (s.u.) ReDox (mV) Turbidity Volume Removed (gallon Water level (u5) (ntu) ml /L) Other (ft) circle. ne 3 /5,s fW2 0, t • ., 0 11, � C� s f Iva ' �' � " � (� 3 s _-. aCeArkttylical r i Dmument Nnme: Field data Sheet Dmument Number: F-CAR-Ft.p-0ol-rev.03 Name and Affiliation (Sampler(s) Name and Affiliation (Inspector):.�i/ e Well Information atlon Well ID: Well Diameter: Total Weil Depth: Static Water Level: 3119 it Height of Water Column: ft Well Locked: ald Data Sheet Review: to -yti-1t Date:Io- zq_Zt Construction: Steel/StaiialessSteel) MultiFactor`:2� r(iiadius/12)2x3,14x7A8] Casing Volume: 3— _ G(, —_ gallons Cal, S Volumes : Y gallons By: G� Pump Intake: sO -It Purge Information Date Purged: a 0 / Z Z1 Start: I OY} 0 Finish: l 0 L] 0 PurgeRate:. Z©p , t„q„ Purging Method:_61 c r n n r,., Total Volume Purged: Ra oo (gallons.. xll /L) Sampling information Date Collected:to /�I/ Z Time Collected;_ 0 pm) Sampling Equipment Used:�ot nnn Bottle Type Preservation Analysis Required: Field Measurements/Observations Sample Temp (°C): 1 3, 0 __Time: l o l.s-_--_ Turbidity (ntu): _ ,', Diss Oxy (m/L): O, N--� Time: t o g y s ------ Time: Fe 2+ mg/L: tj Specific Cond. (uS): is �,cl Time: e: OdorRes.: —Time: P 1' ( Sam le H s•Lu): 6.6 Tim.' (ulg/L)/Time: ReDox (mV); 36 b one une: _._-,-----.-___._--Time:...- ---- — __ T_.. RciDox (EH value):YSI ProPlus +20pmV Z36,o Appearance; cl e_ pime: General/WeatherOoservations: Other: AzI4 Time: V i oudy/rainy Temp. h5 (°P) Wnd— Q- ph) StabiliSample.ati r, na. -c ���n �� Z / Time Purged Temp. {°C) Diss Oxy, (177g/t,) Spec Cond. pH (s.u.) ReDOX Vo time Turbidity removed Water (US) (mV) (ntu) (gaBotas nl / level (it) Other o00S 13.Q ©,'- 3< �r 69. L UP 13, 4GZJ 6.E c lQv© 33,9V ails 12,5 O,S UCisi r r_ <r, I.'G 451S 1040 13.E N �VS9,Z 6.6 38,Z v, 1 0 0 0 3H,(; '6 o00 /...��'xCeftil.Tlytical f i Document Name: Field data Sheet Dmument Number: F-CAR-Ft.D-o01-rev.0.3 Name and Affiliation (Sampler(s): Name and Affiliation (Inspector): Well Information Well ID: ill✓-d/ 1) Well Diameter: 9 1) , Total Well Depth: % % , 0 ft Static Water [.evel: 'q (3 ft Height of Water Column:.; ,g !ft Well Locked: Construction: 1d Data Sheet Review: Date:1 o z9 z, to/-tVo NO / Flushmount i Steel) Multi Factor*: ( iL (+{Radius/IF}2x3!Y4x7.A81 Casing Volume: G ,0.7 gallons Cal, 3 Volumes: gallons Pump Intake: j 5 'V March By: G'.Cc_ �M F Puree Information = ft Date Purged: f G ? —/_ Start:100 S Punish; I i, Purge Rake: f �� Purging Method:_..1'1100S00 1 - Total Volume Purged: (gallons Sampling infornlation Date Collected: (G / ¢ /� Time Collected; Sampling Equipment Used: Zo)9 S6'0o _14Z�L_ Op/pm) Instrument fD: 1% Bottle Type Preservation Analysis Required Field Measurement 'Observations Sample Temp, CC): _ /I Tirne:iLY- 5 Diss Ox m L : ^ y ( g/) a• _Turbidity (niu): v — Time: i r _ Time: Specific Cond. (uS): clFi �� �1 Fe 2+ mg/L. ' 0 � --Time: u _ Time: Sample pH (s tt ): �� r Res. Cl (mg/L)/(Itg/L): '— �Cuue: _.__.-.. Time: _ ReDox (mV). 1J / \O Time: --;ySI Odor:-✓�f� — 5 cir „--.:' ProPlus__. ReDox (EH value):YS[ ProPlus +2p()mv �,y; Appearance: ('%i<' , Time'. Genera —Other: 1/Weather Observations: ( 6/ Time: Sampler Time Temp. Purged (nC) cloudy/rainy) Wind I (lnph) Diss Oxy. Spec o ume m I Cond. pH (s.u.) ReDox Turbidity removed Water ( g/) (u5) (uiv) (ntu) (gallons/bra/ level (ft) Other S u . 7cceAnalytical f Document Name: Field Data Sheet Dncutnen Issued: March 8, 2019 Page2of 2 Document Number: F-CAR-FLD-001.rev.03 fssueing Authority: Pace Huntersville Quality Office Client: lt)L Location: py; I f '�i I✓`✓ Project: bblA 61floe 1"'D• Afb4k. /_F od, 9,021 Well ID: /q\,/-1' 1 � o • 2sl -Zl 646- Reviewed Date and By: Cale}ILI l��r Stabilization Test Well Diameter Multiplication Factor* 1 0.0408 1.2 0.0918 1.623 0,1O30 2 0,1630 3 0.3670 4 0.6530 6 1.4680 S 2.6100 Time Pur g Purged Temp, u (C) DissOxy. (mg/L) Spec. Cond. (u5) pH (s.u.) ReDox (mV) Turbidity (ntu) Volume Re ved (gallons ml L) circle one Water level (ft) Other w Ala 7 ,2 2"1 Date Issued: Mareh 8, 2019 Document Name: Field data Sheet Page: l of eArW441Cal 19Subtg Authority: face tluntersville Quality I Document Number: F-CAR-FL.17-001-rev.03 - Office t LG Name and Affiliation (Sampler(s): L� - pac'_ Name and Affiliation (Inspector):. h-V-y� Well Information Well ID: V\k LV - 1 2— Weil Diameter: 2" Total Well Depth: °�' 9s ft Static Water Level: / -Z • 1 " ft Height of Water Column: & 16 It IC.Project#:�ft cvw�iti Cv. /UewL ocT .2( — Id Data Sheet Review: S'"t- Date: 1CltDLiLt By c'X13 tolti9lu (3�„ Well Locked: C (XES:� NO / Flushmount) Construction:. (& Steel/Stainless Steel) Multi Factor*.. 0,143 r{Radius/12)2:13.140.481 Casing Volume: ) q3 gallons Cal, 3 Volumes: / 2 gallons Pump'lntake: �' A Purge'In€ormation Date Purged: L /�Z rr Start: l YOO Finish: l 15 Purge )7 Purging Method_ 2-1 i s"l110. �p.c Total Volume Purged: 150 o (gallons /L) Sam lin¢Information Date Collected: / u / �/ 21 'rime Collected: / �7 0 _ (am/& Sampling Equipment Used: �l 5�4 c Instrument ID, �6 ;j D 20 3 -rp o 3SS Bottle Type 25 O K..L a(as (- zs v �l K o h. _ 3 4 0 V'L_ Preservation Lkhprco . Y{ C' HcL NCI. Analysis Required Vo c. I q-b Field Measurements/Observations Sample Temp (aC): 1 Q, o Tinte: _Turbidity (ntu): 1 ` 7 Time: / Diss Oxy (mg/L): o', 3Time: / Y•2-P Fe 2+ mg/ L: A)-b Time: / Specific Cond. (uS): 1 5 Time: / VZ O Res. Cl (mg/L)/(gg/L): Pime: Sample pH (s.u.): 3 ... Time:. 9 0Z Odor: Lk47-rO-___ _Time: T _ C[Cat' / �� ReDox (mV): Time: Appearance ReDox (EH value):YSI ProPlus+200mV ;j Z Other: Time: _ General/Weather Sampler Signature:- 0 ,tablization Test cloudy/rainy) Temp. 7('F) Wind__L_�_(mph) (v -2.6-Z-( Time Purged Temp. (C) DissOxy. (mg/ Spec. Cond. (uS), pH(s.u.) ReDox (mV) Turbidity (ntu) Volume removed (gallons/ n,/ L Water level (ft) Omer I 05 /7.3 O, 95/ (,•3 S/7, /,la Sav /2.zc/ �wP 17.3 D. 95) �.3 7,`/ !,!, Iz. it {ytv / ,v O.tf 3 ��• S 1. /a�� 1a-2.7 t�15 a D.V 94, 3 �9tq o•S 9S�o ��.� Document Name: Field data Sheet Elate Issued: March 8, 2014 • I of I eAn,?1yl1W1 IPage. bycument Number. F-CAR-FED-001-rev.03 Issubig Authority: Pare Htmtersville Quality Office ELF Name and Affiliation (Samgler(s): `� G " �� r� r Field Data Sheet Review: S By: CT Purge Information Date Purged: ! / LG /L 2I Start : / 3 2-0 Finish: 1335 Purge Rate: Purging Method: t STD �' ( Total Volume Purged: 154,0 (gallons/(! /L) Name and s- well ID: n ' % z Well Affiliation (Inspector): Date: jo(2�i(21 Well Information It7(i it Sampling Informiation Date Collected: t ° / 2G/ z-( Time Collected:) 3 Z U _ (am Sampling, Equipment Used: e t �V U' e _Instrument ID: (� b �3 TQW�S Bottle Type o L%,,L e l mL Field Measurements/Observations Preservation (r(GL (JCL Analysis Required T(� 5 V6 C_ Sample Temp ('C): / 7 • ) Time:. / 3 `10 Turbidity (ntu): 3,q Time: 3 y� Diss Oxy (mg/L): G ' 5 Time: ! 3 V O Fe 2+ mg/ L: N- Time: Specific Cond. (uS): q7 7 Time: / 3 Y D Res. Ct (mg/L)/(µg/L): Time: Sample pH (s.u.); eb>' ✓� 2%_.._._Time: / 00 Odor:_.. Lw5)N-,— ._ Time: -- / 3 D ReDox (mV): S' o Time: 3 V� Appearance: Cbec� Time: / 3 Y0 ReDox (EH value):YS.I ProPlus +200mV ?'l 5 • Other: Time: General/Weather Wind -/ 3 (mph) Sampler Signature Stabilization Test LF- Oci Spec Voume Time Temp. Diss Oxy. Cond. pH (s.u.) ReDox Turbidity removed Water Other Purged o (C) (mg/L) (uS), (mV) (ntu) (gallonsfrtt / Ieve1(ft) L 132.5 I c.7 470.0 I 6,•2 500 it.Og 'D IF 15.7 cq .7 g70.0 Z Sao 33a /Z, t D.Cv 41ei.(o g 7 6- 5 `i.1 / o00 !l•!� t3a t� g o.L. 4iy.1 c�.sr -Is.7 .3 , soo 11.,Y Document Name: Field data Sheet Date Issued: March 8, 2019. Page: 1 r3GP.N7r71yliC8f of [7dcument Number F CAR-FI..13-001-rev.03 I:ssuuig Authority Pace Huntersville Quality ... r� Office L Name and Affiliation (Sampler(s): ' ' 74 ce _ Name and Affiliation (Inspector):. V VNA- -- Well Information Well ID: M w - / 3 u Well Diameter: 07 Total Well Depth: 15 3� ft Static Water Level: �` �� ft Height of Water Column:/0.7 2-- ft A) Data Sheet Review: Date: 1Gl21 f zl 10(�q �L) Well Locked: 4YE5 / NO / Flushmount ) Construction: (&/2Steel/Stainless Steel) Multi Factor*: V `3 r(Radius/92)2x3.14x7.481 Casing Volume: / 5 gallons Cal. 3 Volumes; S ' .)s gallons Pump Intake: 13 • v It 1� LF-Off'z(— By: a"' 131. I Pure Information � kV_ / / /it� Date Purged: I ° / Z� / c Z 11 Start : 3 7 Finish- / 51 5 Purge Rate: -- Purging Method_ D "L.Sr`x l Total Volume Purged; Zu o (gaitoiis(nlll� L) Samplinglnformation ✓ Date Collected: tt q / 2-G/ 2-1 11 'rime Collected; ' S J .._ (am/Qi Sampling Equipment Used: 5 It Instrument ID: r� 3 TPG J5s Bottle Type 3 - Lf u .V, c Preservation d%oy_�', - aCL Analysis Required __--_.i^�_lala�__.,w __......_.... Field Measurements/Observations ISSv Sample Temp (°C): _ 15 • S�) Time; _Turbidity (ntu): '3 • � Time: l 5 SD Diss Oxy (mg/L): 0.3 Time: 15 Sb Fe 2+ mg/L: Time: / 5 50 Specific Cond. uS : p ( )( 4 � • 3 Time: 15,50 Res. Cl m L ` g/ )/(ttg/L}: 'Tune: Sample pH (s.u.): _L ``. 5 .._... Time: / 5 S D Odor: K _...__ Time:..... I s U ReDox (mV): G I Time: l S SD Appearance: Gila rime: / 55D ReDox (EH value):YSI ProPlus +200tuV • R Other: -- Time: —� General/Weather Observations: Sampler Signature Stabilization Test cloudy/rainy) Temp. SZ (°I) Wind 7 (mph) /0- 2G' 2 Spec. Volume Time Purged Temp. Diss Oxy. Cond. pH (s.u.) ReDox Turbidity removed (gallons Water level Other (C) (mg/L) (us) (nv) (ntu) (ft) L ( 35 iS,tf o.y `(G .3 (0.5 f5 �400 ID 1'VQ 15.`F o,y 4`G •3 G.5 154, 9.4 — i5b t5.5 c, ,,3 art sf,6 G.5 9.1 a. u </ 12_G6 �, 6aAntx"101 +r Document Name: Field data Sheet. Pate Issued: March &, 2019:page:. 1 of 1 Document Number F-CAR-Fi,D-001-rev.03 lsmiug Authority Pace Huntersvilte Quality Office --BL Name and Affiliation (Sampler(s): C' 1�c c-c. Name and Affiliation (Inspector): i`ly 1n.L. Well Information Well ID: r t W 1 3 Well Diameter: as Total Well Depth: q � ' 63 it Static Water Level: —21 Y ft Height of Water Column:3�, 13 ft Well Locked: ) C Project #: Bkneoh1C �• �� I- - Oct ,7-\ — .ld Data Sheet Review; U ti Date: I of 4121 By: cv5 10113121 VAS Construction: E5/Steel/Stainless Steel) Multi Factor*:Ok/G3 r(Raadius/12)2x3,14x7.487. Casing Volume: a gallons Cal. 3 Volumes; 9, 11 gallons Pump Intake: Lf �• d ft Purge Information Date Purged: l o / 'Zb / -7-11I j Start : 1 t l S� Finish: j s� s Purge Rate: l o o `-1 � Purging Method: i 4 l 0. l� c Total Volume Purged: 2-0 . a (gallons g/L) SamplinizInformation Date Collected: lb / 2-G/ 21 Sampling Equipment Used:___1%e t Time Collected: / s �_ (am/(@) Instrument ID: y S1 * 0 2X3 TPw :4 d 3SS Bottle Type Preservation i - Z50 t,,,l pe s . /J0,3 a-gL? o.. Hct_ Field Measurements/Observations Analysis Required Uoc Sample Temp CC): % y —/ Time* 5 ._Turbidity (ntu): " Z Time: / s� Diss Oxy (mg/L): 0.3 Time: /S'Z6 L /2 Fe 2+ mg/L: Time: / 5 Specific Cond. (uS): �2'�.% Time: /��o Res. Cl (mg/L)/(ltg/L): — 'rime: Sample pH (s.u.): —(e,3Time: / 5a Odor:_ _ ReDox (mV): 5 2 •% Tune: / �oZ� Appearance: Cl ear rime: ReDox (EH value):YSI ProPlus +200niV 2- Other: Time: GeneraVWeather Sampler Signature Stabilization Test y/rainy) Temp. !o -ZG•z Spec. Volume Time Temp. Diss Oxy. Cond. pI-f (s.u.) ReDox Turbidity removed Water Other Purged (C) (mg/I) (US) (MV) (ntu) (gallons/®/ level (ft) L 1500 7.7 ya •3 iS. (9. bD I.Sz 'D e l .� a.� N3.I •3 (,a-. . 7.52- 15v5 1 Lt,? d. 5 yzl,,% 6.3 5'9• *,L 3.3 1 D00 �Y. o"l 115iv 11t,l, 1 o.y y�71 L.3 s .v lst, g, ly t515 1 iIf. g, I o.3 I g23.6 �•3 sy, ),3 9-00 za Document Namc. Field data Sheet Date &sued: March % 2019 r 0GCF11k71ytiCa! Page:: I of J C7gcument Number. FCAR-F•[ t)-0O7-rev.03 Issubig Authority: PaceHmitersville Quality Office Client: � L£ F...ge�I..d Data Sheet l 1 Location: L�5 V 1k AJQ- Project Ob av\cawtbT Co . NC Lr-oet 2 1^ Name and Affiliation (Sampler(s)c C' LG " � Field Data Sheet Review: Name and Affiliation (Inspector): Date: 10f7-41 l By .� Well Information 1011.911) 13M1r Well ID: VtiW - I �1 Well Locked: / NO / Flushmount )' Well Diameter: 2" Construction: �V °Steel/Stainless Steel) Total Well Depth: 62- It Multi Factor*:Ot 43 r(Radius/12)2x3.14x7.48l Static Water Level: -2 9, 9 2- It Casing Volume: -7 3 gallons Height of Water Column: �Z• 11 it CaL 3 Volumes: 1 1 ' 19 gallons Pump Intake. 5b ° ft Purge Information Date Purged: 10 / 2_& 2_ I Start. / 2ZO Finish: / a �S Purge Rate: (O p h, L- �= (&/ Purging Method: o n So u Y. Total Volume Purged 2 Sb ° (gallons/ L) Sampling Information Date Collected: 0.a / 74/ zl Time Collected: L 7-5 0.,.._ (am/Q Sampling Equipment Used: Y $O" Instrument ID:7*r#o2'3 Tow o-;5✓r Bottle Type Preservation Analysis Required 2..5 n t, L, p�CtS (�h r eS. Tb.5 l- -250 wt �lao. o Mwf. /S 3 L(o AtyaA HCL Vor— Field Measurements/Observations Sample Temp (eC): % t% z Time:. / � _Turbidity (ntu): 7 Time: / a5 v Diss Oxy (mg/L): 5,1 Time: I � S Fe 2+ mg/L: N -D Time: 2 5 0 Specific'Cond. (uS): f 7g & Time: I �25 v Res. Cl (mg/LV(ltg/L)i —'rime: —� Sample pH (s.u.): 4 " -2, -----Time: / -1- 5 b Odor:_ _.- � _.----- Time....... ReDox (tnV): 7 V - `'' Time: %,'-SP Appearance: de4r' Time: ReDox (EH value):YSI ProPlus +200mV 270.0 Other: Time: General/Weather Observations: Sampler Signature Stabilization: Test /rainy) Temp. S!, ff) v • Z6- 2/ Spec. Volume Time Temp. Diss Oxy. Cond. pH (s.u.) ReDox Turbidity- removed Water Other Purged (C) (mg/I) (us) (mV) (ntu) (gallons/�/ level (ft) L z�5 13•� g /88.1 C.Z 5-S.1 27.2- 50c? 30.5 awpj 3.v `F. 12%!.1 G•z- '55,1 027.2 3a.5 lZ3o 3. Qi q,7 ISy,� L•z Si I o1 7 /tJao 30.G Iz�Si q( 55.0 ISlO.L (a•2 `z•3 1 / h 3o,7s� 1 L`do 1 q_5 ES.c, /gD.N &Y,0 1 13.7 'Aoo0 IZ'f5 ILf.4 5.1 119.9 (.•L (-5.2, ii.5 X500 30•77 Ark*tiCd1 ;E�xunientName., NnmFinld dataShec@. Date I hl, t Number: F-CAR-FLD-001-rev.o3 Lnuu,g Author Field Dat Shee Client; Locationn: 5 t'2, A' L Project#: 3k Name and Affiliation (Sampler(s): �' L G _ t A c�J=niRun1tejvw' Name and Affiliation (Inspector): VYry. Well Information Well ID: IvIW ` l t{ Well Locked: NO / Flusho Well Diameter: Total Well Depth: 9 1. 5y Static Water Level: 3yft / • 3 I Height of WaterColumtlel•l9 £t Construction: Steel) Multi Factor*: ®' G3 (*(Radius/12)2x 3:14 x 2.481 Casing Volume; 017c� gallons Cal. 3Volumes: a5, O gallons /Vew LP- Oc� ,V - c t1?> By. 13, r Pump Intake: n• o ft Pure Information / Date Purged: 10 / a � / Z1 Start- I ( I �{ S Finish: �j D Purge Rate: 1 0 D h- L / ( �' Purging Method; KA_0 .5 C>UT Total Volume Purged: 1 S.- o anon m L (g / ) SamplingInformation Date Collected: I u llc 1 I z U j —�—/ Time Collected:: Sampling Equipment Used: �-�0 0 0- Instrument ID: y51 d 203 1-fCV 4 a 35S Bottle Type _ -- z50 h,L- P'GS / z5u ry lC plus Field Measurements/Observations Preservation I n+�s t{lJO _I_-26l"IGL Analysis Required � •IYTG( yOC Sample Temp (°C}:, / 3• S Time: �s _Turbid: ntu: a • 2 0-5 - — $' ( ) � Time: � Diss Oxy (mg/L): 02 - 2- Time: 12-05 Fe 2+ mg/L; %✓ L Time: / 0S Specific Cond. (uS): 3 3 :L' Time: 1 2-0s Res. Cl m)/(µg/) L L : ( g/ Time: Sample pH(s.u.}: . ___--_Time:. /ZOS Odor: - 0"' -- —. ReDox(mV): 5G• I Time: /-'-O5 �/ Appearance: ` ,ecit' Time: /ay$ ReDox (EH value):YSI ProPtus +2oomV zSG , 1 Other; General/Weather 1- Sampler Signature: ✓ n _ Date % v - Z-6 - Time Purged Temp. (°C) Diss Oxy. ( m Sec. P Con). pH (s.u.) ReDox Turbidity volume removed g/)I, (US) (tnV) (ntu) (gallons/ 11 / 13.1 z• Z 332-5 7. Z G3.8 L sc, Dh� 131 z.Z 3325 7.z !3� �! b�SS I 2, Z -43u.9 7.3 59. I LOb 13.5 o2. 1 31. S' 7,3 57- 0 7.-A I v sun Wind /-5 (mph) Water level (ft) Other 30.8' 3 /z aeeAnalyllcal i E Dmunient Name: Fidd data Sheet Document Number: F-CAR-FI,.D-001-rev.03 Name and Affiliation (Sampler(s): !' C- - e, c-e Name and Affiliation (Inspector): Well Information Well ID: m lni- (% Z Well Locked: Well Diameter: Z Total Well Depth: oZ (o • q S ft Static Water Level:1 6 1. lox-a?ft Height of Water Column:( a 61 ft C Project #; Sun�rrvt �p �Cp. nl LF- o�_f ,z( Field Data Sheet Review: �t..i; Date: po/Z9I7� B CZt3 Io�2Q �21 y BMS Construction: NISI/Steel/Stainless Steel)' [Multi Factor*; �'/�3 1+(Radius/12)2.x 3,14 x.7.481 Casing Volume: 1,73 gallons CaL 3 Volumes: lJ, 19 gallons Pump Intake:It Purge Information Date Purged: 1 0 / 17 / —A' Start- / v 05 / 0 " �i / L 1 Finish: Purge Rate: � o(,V Purging Method: Itwfe4 lc Total Volume Purged: y �0 allons ' (g Idg/L) Samylin¢ Information Date-Cdllected: 10 /d7/ rZ( Sampling Equipment Used; Time Collected; l? s Bottle Type Preservation / • a 5o ML �GS ((y�pl'e$ - a5v na(- (as �A)0 3 - K 0 n,( C-L., --3 -`� a--"=L N c Field Measurements/Observations oxP3 Taw *-0355 Analysis Required 1u �fiG /s V 1G e- 1, ` _ Sample Temp CC): / U • Time: ° ZS _ Turbidityntu : ( ) 5. 2 Time: 0 / Zf Diss Oxy (mg/L): 3, t Time: /0 2 5 Fe 2+mg/L: / Time: 10 ZS Specific Cond. (uS): 1 s • i Time: / U ZS Res. Cl rn L g ( g/ )/(!t /L : Time: Sample pH (s.u.): 4' S __... Time: U 2S Odor:—__ Y\ `_¢__// 1J 2 f ReDox (mV); 3.7• `/ Time, !v ZS Appearance: __.._—_Time: C� lzQ r- __ •Time: / J 2S— ReDox (EH value);YSI ProPlus +200n1V 23 7, °/ Other. _ General/WeatherObservations: Time: Sampler Time Temp.41DissOxy Spec.Purged (°C)/L) Cond. pH (s,u.) (uS)10 1 0 10 , 2- z( 9,.Z) ice. zD �19. Ilull /o.� z1� -G,5' 0 crouaYlramy) Temp. Y K CF) Wind 1 C2 (mph) ate: /0- a7 2( VoTite ReDox Turbidity removed Wa/ 7rZ(mV) (ntu) (gallons level 0 v1 15, 77 0 _,,.+ry taocument Name. Field data Sheet pate Issued: March 8, 2014 j: Alk?✓k 1/Ca1 f Page: 1 of I L'3ctcument Number F CAR-F•L.p-0Ql-rev.03 Issuing Authority: Pace Huntersville Quality Office j3 L jE Name and Affiliation (Sampler(s): Name and Affiliation (Inspector)-.. Well Information WeII ID: M'j- I. Well Diameter: 2" b1K Well Locked; Total Well Depth: H (' ' . ( ft Static Water Level: , � 3 ft Height of Water Column: ft 54 Data Sheet Review; Date: lO fz91m iult-1NI �77 NO / Flushmount) Construction (i'y�%Steel/Stainless Steel) Multi Factor`; 0.163 ['(Radius/12)2:x 3.14 x 7,48] Casing Volume: Lf` 61 gallons Cal, 3 Volumes; 13 'S 3 gallons Pump Intake: 3 R It CTI3 By. ap-. Purge Information Date Purged: 1 0 / 1-7 / 21 II Start: 0 � 9 �5 Finish: g 5 ° Purge Rate:h Purging Method: i ,1T , Total Volume Purged: 3 S a O (gallons nl L) Sampling Information U g SS Date Collecked: to /z7 / 2 I Tirane Collected; __0/pm) Sampling Equipment Used: �i''S�aII!, Instrument1D:Tr'*0?-03-rpw-46,3SS Bottle Type I 2-5 o rr.c- p(is f ' 2-5 ML P [[ S 3 _ 't V IL 3-'ion,(_ Preservation Lkwp N r-L IJe Field Measurements/Observations Sample Temp (aC): 5 Time: 9-ss _Turbidity (ntu): Analysis Required 'rJ).S C. Diss Oxy (mg/L): 0 ' Y Time: O 07 53 Fe 2+ mg/L: � - O Time: O 5 65 Specific Cond. (uS): 176' 7 Time: 015S Res. C1 (mg/L)/(ltg/L): 'rune: .-- Sample pH (s.u.): 7. 2— Tin -9 9 55 Odor:_-_ _.._____Time: ... U i SS_ ReDox (mV): d-5' 2' Time:.) 9 55 Appearance: d eon Time: 0155 ReDox (EH vatue):YSi ProPlus +200mV ;L'�O 2 Other: — Tune: cloudy/rainy) Temp. 415 ff) Sampler Signature Stabilization Test Spec. Volume,_ Time Purged Temp. u (C) Diss Oxy. (mg/L) Cond. pH (s.u.) ReDox (mV) Turbidity (ntu) removed (gallons/0/ Water Ievel Other (us) (ft) L 093t Io.3 0a8Q,3 (,•mod 57.5 `f oo I e / 0.3 -0.7 ;299.3 (.A 675 41.6 111,51 0135 1D.Z, 0.5 a•79,q '7. `f3.9 a.s- /C&0 /y55 0 9t10 1/0 0.5 ja77.3 1 -2, 3 r. 9 (•Y I zf na 1 /y.57 u 9`15 v.5 0.5 12,77,11 -7.t 57 6 cs.3 1 2$Vo I /Y,// 0 950 10.4 D - Lf 277, y 7.7- z5.3 0.7 3500 ACCA/kTlyffCAl Lkrcuo5ent Name: Field data Sheet Date Issued: March 8, 2019' Page: I ot7- ., ' [J�cument Number. F-CAR-Fl..p-0Ol-rcv.03 Issuing Authority: Pace Huntersville Quality y Office Name and Affiliation Name and Affiliation Well Information Well ID: All1✓-�� Well Diameter: r /? }� Total Well Depth: 5 [.. U ft Static Water Level It Height of Water Column: ut 6-ft 1. Well Locked: Construction: !Id Data Sheet Review: Date.ie Steel) Multi Factor*: U l(a > i+(Radius/12)2x3.14x7,481 Casing Volume: gallons i Cal, 3 Volumes: '' a(o gallons —� Sex,- Aq By. C !fir Pum Intake: SO . C "' ft Purge Information POA910 Date Purged, f Jam/ Start: Finish: Purge Rate: Purging Method iylScc; /1 Total Volume Purged: i . S G (gallons/ 11s l,) Sampling Information Date Collected:_/1_1 / ( Time Collected:_ ` am m _-_( /P Sampling Equipment Used: l nS('(4 Instrument ID: t 3` Ji1 f9;c Vd7 1� Bottle Type Preservation Analysis Required "Vi -cry Field Measurements/Observations Sample Temp (eC): _ �/ Time: C660__Turbidity (nm)_ Time: Diss Oxy (mg/L): ( G Time: Fe 2+ mg/L: Time. bl�����u Specific Cond. (uS): Time: Res. Cl (nig/L}/(hg�/L}: Time: Sample pH (s.u.): _Time: Odor:__.-✓'�,'r__._-_ Time: 'Ile_ ReDox (mV): l U?a o Time: Appearance. 16-Timer ReDox (EH value):YSI ProPlus +200mV 3 c'9, 2 Other: IV 6 Time: General/Weather Observations: e� . (funny)/cloudy/rainy) Temp..(°F) Wind (tr Sampler Signature Stabilization Test Spec. Vo urne Time Temp. Diss Oxy. Cond. pH I (s.u.) ReDox Turbidity removed WT(ft)Other Pwged (C) (111g/L) (us) (mV) (ntu) (gallons/�Iev L Al lei, "lo A (,—�e l 67ay 1507 S. a(?,� (30, � "�^ S� 2 �j�(J' Z i J oa d =I s - - -6 !2 r;�r Document Name: Document Issued: March 8, 2019 .. �ceAr��ltylrc<�( Field Data Sheet Page?o£Z- Document Number: Issueing Authority: P-CAR-Fi.D-001.rev.09 Pace Huntersville Quality Office Client: Location: / 5- ev' Ile - Project: 6 dI ocoU ok C,3- Ad;,IP� oct 2011 S Aqqe' X""( Well ID: /0 fin/ " ( tl f*.Z0_ZI Gars Reviewed Date and By: f o/2x /ti L��S Stabilization Test 1\Tell Diameter Multiplication Factor" 1 0.0408 1.2 0.0918 1.623 0.1030 2 0,1630 3 0.3670 4 0.6530 6 1.4680 3 2.6100 Time Purged g Temp. o (C) DissOxy. (mg/L) Spec. Cond. (us) pH(s.u.). ReDox(mV) Turbidity (ntu} Volume Re ved sJ (gallons !s ) circle one Water level (ft) Other ..3 S V.5' S, C 2 ILY C- 7 105L c1 U 750 c1 r, -7 Sc r S, �.15 S - 7 Ow/', G 0CIO I C-leI r Sa� '11511. 6 ( 0q, l' a .)So oS� 1 6,7 t f 2 IL 1 O c (S. 5,. 0-1 111 sOcNI,0 ? 11?0� I '' -s ;. 5. 7 q,r � I33 7 I11 �r l'7�iCs "i �+ �W S 7 214. aceNtaq ffeaf' Document Name: Field data Sheet i Document Number: F-CAR-FLD-oln-eev.o3 Name and Affiliation (Sampler(s): Name and Affiliation (Inspector): . ,N j'A �— Well Information Well ID: r CY:vVt_ R n Well Diameter: _ Total Well Depth: ft Static Water Level: _ ft Height of Water Column: _ ft Purge Information 1d Data Sheet Review: Date: Iu/2`I (z( ioIAP,I • t) C IL Easee Multi Factor": ['(Radius/12P x 3.14 x 7.48] Casing Volume: — gallons, Cal. 3 Volumes: — gallons Pump Intake - By: Date Purged: _ /_/ Start: Finish:— '— Purge Rate: -- Purging Method: Total Volume Purged: allons mis L Sampling Information Date Collecfed: f 0i . /*' Time Collected: I t 13 (ym (1 Sampling Equipment Used: v c b Instrument ID: YS� p roo � J-K- 3�r} MtLn� lY�� ra o Bottle Type preservation A I •_, 1 L nalysis Re d AIG.sI-.L tc ryJ -t-I Q rwL 1/tq.Ci Field Measurementons al0 s .1 re Sat h\V-lu Sulb�k IA1k I CI , tirYn nnn 1a 1 S C CIS 49T s V O C Sample Temp (oq: K .Q Time: q _ Turbidity (ntu): Dins Oxy ( m L : Time: t 3 g/) .`1 Time: 13� Fe 2+mg/L: Nl Specific Cond. (uS): `I4=�Time: me-' — ._ TiTime: Res. Cl (mg/Ly(µg/L): Time:. — Sample pH (s.u.): k Time: �l / Odor: L ,_g_ C."s.pn�Time: ReDox (mV): )� Time: ) `1 0 pp _ A earance: I� kacIC Time: .� k3 � ReDox (EH value):YSI ProPlus +20llmV .M I Genera Other' Time: 1/Weather Observatinnc 1 M O Y' I ]in4,es - a rn --e7 I�.rtl. JQ .I NCI tsurmy ouay/rainyF) Temp.�(OF) Wind I! (mph) Sampler Signature• Date: Ia Time Temp. Diss Oxy. Spec. o ume Purged (eC) (mg/L) Con pH (s.u.) ReDox Turbidity removed Water (US) (mV) (nm) (gallons/mis/ level (ft) Other Document Name: Pielct duM Sheet Date Issued: Marc] 8, 2019 ase/limlyticat ` Pa e: t of l Document Number. F-CAR-Ft,D-001-rev.03 Issuing Authority: Pace Himtersville Quality Office Field Data Shee Client:iS L'+` Location; 1U-fC Project #: n C Name and Affiliation (Sampier(s): = - a (-t �1na l�} Ce,) Field Data Sheet Review: Name and Affiliation (Inspector): N 1 A IPifv) N-A Date: Well Information �` I A Well ID' s-CI�-i�=i- tRe C�tGC W` . Well Diameter: C an: ee : am ess tt - — TotalWellDepth: ft Multi Factor*: — [(RadiusJ12)2 xBYi4x7.t8] Static Water Level: ft Casing Volume: gallons Height of Water Column: — ft Cat 3 Volumes: gallons Pump Intake: _ ft Purge' Information Date Purged: Start: Finish- Purge Rate: By: 4 e 1-t= 0 l.�rnat . Purging Method:_ Total Volume Purged: (gallons/uils/L) Sampling Information Date Collected: 1 0 j?_'L j - Thne Collected:- `' , Q ( p ) Sampling Equipment Used: 6'a6 Instrument ID: �/ ST ft (�L fk3_y�� (vls u oTG w * �o}q Bottle Type -'-lowl..rTGts Field MeasurementslObservations Preservation ,ja Analysis Required ©T cl( S ._......__. Alp�Z�Joc Sample Temp (°C):j •B _Time:_�I QTurbidity(ntu): ;�` —Time; ]� 1 � Diss Oxy (mg/L):.... S } Thne:�_Pe2+mg/Lt t4) Time: I- i—D Specific Cond. (uS): t I�iS • Time: ��AM ,Res. Cl (mg/L)/(µg/L): — `Dime= `— SamplepH(s.u.): ��._... Time:-)� l� Odor:_--N_.... -- _�Tune:....t_`_'t1_—. ReDox (mV): Time: Appearance: Gl e `Time:_ ReDox (EH value):YSI ProPlus +200mV -Tr . Cl Other: Time: General/Weather Wind t 1 (mph) Sampler Signature Stabilization Test Time Purged Temp. CC) Diss Oxy. (mg/I,) Spec Cond. (us) pH (s.u.) ReDox (mV) Turbidity (ntu) Vo ume removed (gallons/mis/ L Water level (ft) Other Q B S,� S lola�61 r'GkNylfea/' Document Name: Field data Sheet Date B t . Document Number. F-CAR-FLD-001-rev.03 Issuing Author FieIdFieId Data Client:_ � lir Location: �is�on.-I,la Name and Affiliation (lei( SamPs): Project #:]3� .. �' dal ��( Name and Affiliation (Inspector); l..r I f} Field Data Sheet Review: Well In on,o ONI-b- 1 Date; Ycd�'i 17a Well ID: L Y t n Mo/l 41 Well Diameter: Total Well Depth: Static Water Level: Height of Water Column: C Multi Factor*: . _ [•(Radius/12)2 x 3.14 K 7.481. Casing Volume: gallons Cal, 3 Volumes: =� gallons P — By: A-d, ,- LFock.D-)at�{j Purge.Purge Information U'nP intake:�_�t .Date Purged; Start Fm'sh: Purge Rate: Purging Method: Total Volume Purged: (gallons/mis/L) Sampling!ampling Information Date Collected: l�-2-Z;/ a\ Time Collected: (a pm Sampling Equipment Used: G ` , Instrument ID(u y tk 3Y ? Bottle Type :_y Sr A- cn I I (Y[vLcvTP a J Preservation � 1 � a ysis Required Field Measurementa/Observations Sample Temp (oq: -', Ttme: I Turbidity (ntu): LA of Time: Time: 1 � a Fe 2+ mg/L: �. (� Specific Cond. (uS): 3 13 —?- Time:. [ Time . ) Res. Cl (mg/L)/(µg/L): Time:. Sample pH(s.u.): �i,� �- Time: i S3 Odor:_, �2t� C�k Time: ReDox (mV): 36 4 Time: .i t $ Appearance: Uy�� ReDox (EH value):YSI ProPlus +200mV --Te S3 .._ ...._ -l-i Other• Document Name: Field data Sheet Date saRnatylic 1 i Document Number F-CAR-FIa)-00?-rev.03 Field D__ _ata Sheet Name and Affiliation (Sampler(s): -Y-_ • �q(z awl +rc— Name'and Affiliation (Inspector): N -_-_6- We11 Information Well ID: L> We i. n kF i r Well Diameter: Total Well Depth; Static Water bevel: fk Height of Water Column: ft 1'raject cJ, C- F 0c(Flo �a( Data Sheet Review: ,3 Date:14fICI By: CM (� Cost . an Mess e@ ) Multi Factor*: r(Radio8/12)2 x3:1¢ x 7.Asj Casing Volume: gallons Cah 3`Volumes: — gallons Pump Intake:�_ft Purge Information Date Purged: — f=/ — Start: Futisit: —' Purge Rake: — Purging Method:_ Total Volume Purged: (gallons/cols/L) Sarntsline In�Qn Date Collected: 10 /fig / a�_ Time Collected;_.) �a -- Sampling Equipment Used: Instrument ID:/S_ (am/ cn Bottle Type P Field Measureme t Observations re servation >-A-Cj _ Analysis Required Sample Temp (°C}: (� Time:: 1 �Q Turbidity (ntu): _S3-'7 Time: Diss Oxy (mg/L):�"3_ Time: Q g/ -�_ Fe 2+ m I,; Aiy� Time:oV- Specific Cond: (uS): Time: 1 _Res. CI (nig/L)/(ltg/L): Time: `— Sample pH (s.u.): , (•ta+n ______ _.. Time; i Odor:_ . i S�Oc- ReDox (mV): 81 �' — ---.-_ .— _ Appearance: S) i 5A c iou Time: /�0 r ReDox (EH value):YSi ProPlus +200mV t 7 r General/Weather .Lime. 1f Weather bbservaeinnx• Temp, � (`F) Wind 1A (mph) Time Temp. Diss Ox . Spec. o time Purged ° y Cond. H' s u. ReDox Turbidity removed Water g (�) (tng/I) (us) P ( ) (mV) (ntu) (gallons/mis/ level (ft) Other Document Name: Field `data Shu,. Date EBR171l1}/llEa7 fow r Document Number. @-CAR-PIA-001-mv:0.3 lasuing.Aathm Field Data Sheet Client,-_ �j (� _Location: Prolect#: un, Name and Affiliation(Sampler(s):�5�-i&ocn Ana(r cad Field Data Sheet Review: Name and Affiliation (Inspector): `/ WellIn—nfOrMatiOn it/fL`t/2d Well ID: 71 Date: �aida�dlwall T Well Diameter: Total Well Depth; _ ` _fit Multi Factor : } [ (Radius/12)2 x 3,14 x7,481 Static Water Level: ft Casing Volume: gallons Height of Water Column: ft Cal. 3 Volumes; gallons Pump Intake — Purge _TInformlion• DatePurged: � /_/ — Start: — �- Finish. Purge Rate: I of 4e+- ,e Lw oLt.D<)D_I M By: 4 Purging Method:- Total Volume purged: (gallons/mis/L ) Samnlin¢Info� r_ ttratiou Date Collected: (O / ) B —1 -Dtk- Time Collected:_ 1 S _ (ant/ m) Sampling Equipment Used: 6 mb InatrumentID_YSr (.us -z� Bottle Type--iCy1�UnYOwa 30 Preservation A l 4owl qAv:�'- Field Measurements/Observations na ysts Required ._---e4FG:(s _ -.._ ,4 01)t � to C Sample Temp (aC):_ Turbidity (ntu):% Q ` Time: l� Diss Oxy (mg/L):_ Time: )( Fe 2+ mg/L: a O SpecificCohd: (us): � Time: 1 —"�--Time: Sample pH (s.u,): t can � __Res. Cl (mg/L)/(pg/L)= Tbne: (, , — _.____,Tih1e: f� Odor: M ReDox (mV); �6-1 _.. _P1}4.11_L__.._—Tirne:._ - �- Time: (_(��Appearance — ReDox (EH value):YSI ProPlus +200mV4- -Time: r1 _ Dcxument"ame: Field data Sheet Date GeArk7lyNcal t Dmument Number: F-CAR-PIA-001=rev.03 l�uutg Autho: Field Data Sheet Client, -- Location; )byC Name and Affiliation (ler Sam s : Project #: P (� = e ( F` Co-k Field Data SheetReview: Name and Affiliation (Inspector): A }( Well I—of°nn— a _lion Date: L., I Well ID:_ 1 D_ t 1 .Wells r a. �......;., Well Diameter: Total Well Well Depth; — ? "-'- —fit Multi Factpr*: ~ r(Radius/12)Zx 3.14 1.7.481 Static Water Level: — --------ft Casing Volume: gallons Height of Water Column; ft Cal.3 Volumes; gallons Ackt LP 00 ,DcY�,( By: NPA- Purge Information Pump Intake:�_ft Date Purged: f_ Start: _ Finish: — Purge urge Rate. - Purging Method:_ Total Volume Purged: (glons/i1tlsjI,� Sampling Infoematlon Date Collected: 1 c) / O/ Time ColleetedcV) (, Sampling Equipment Used: - Q -------- (am/0 Bottle Type --- InstrumentID_�/S� Preservation Analysis Required iClnt I .,J0\ ADD`(' �lclr Field MeasurementslObservations Sample Temp (°C): —A-6 , �Time:-A4 Turbidity Diss Oxy (mg/L): P'-T (ntu): L ,a Time: . Fe 2+ mg/ L; +--n--_._____-__Tmle. --------_— Tune: b Q ' 6I � Specific Cond. (uS): S (� Time: _Res. Cl (nig/T)/(ug/q. "tune: '— Sample plt(s.u.): Odor1� Time: 1;eDox (mV): �� . ' I --------- Time: ReDox(EH value):YSIProPlus+200mV Appearance: �Zilow •(n�--•Time:___-______ Jb10 General/Weather Observations__ -v---------- — Genera 0tiler: Time: Sampler Temp. S_(°F) Wind l a (mph) Time Temp, Diss Oxy. Spec. Vo ume Purged CC) (n1g/I) Cond. pH (s.u.) ReDox Turbidity removed (us) (mV) (ntu) (gallons/mis/ 10 Water level (ft) I Other Document Name: Field data Sheet Date Issued: March S, 2019' BGeNt,Tly(iCa! • page: I of „l Document Number: F-CAR-Fl.D-0Ot-rev.03 Waing Authority::pace Huntersville Quality Office Field Data Sheet Name and Affiliation (Sampler(s): �--P--Z---q�zc o 4Ac-� {t 1 field Data Sheet Review: Name and Affiliation (Inspector):. nj + � i} ,U�i�� Well Information Date: told�+ld f Well ID: LD 1 u Well Diameter: am ess Total Well Depth: `� ft Static Water Level; ft Height of Water Column: — ft Multi Factor*: — r(Radius(12)2x3ti4x7,481 Casing Volume: gallons Cal. 3 Volumes; — gallons By: Pump intake: ft Purge Information Date Purged: / " / — Start: Finish: Purge Rate: Purging Method: Total Volume Purged: (gallons/mis/1) SamplinEInformation Date Collected: f Cl / X13/,.a�_ Time Collected _ L'�1L\___ (anop ) Sampling, Equipment Used: 6 c-c�` _ � " 1— Instrument Bottle Type Preservation Analysis Required 1��Cg tit uA t 0.Z ? yJ�>71Cc3(�e- Field Measurenrents/Observations Sample Temp (eC): ` �. _Tine:, I ; 1Q.-._Turbidity (ntu): IQ • Time; 1 S-.No Diss Oxy (mS/L): 3 t' Time: I Fe 2+mg/L Nl� Time: l''� O Specific Cond. (uS): _ Time: j Res. Cl (nig/L)/(ltg/L): -- Time: Sample pH (s,u.}:Odor:__.._ .__rvl .._.... Time: \ i aq_ _ ReDox (mV): ) Q l • i l Time: _� C f� _ Appearance: Sl �n1y l .• Lime: ) �s ReDox (EH value);YSI ProPlus +200m V _ Other: Time: General/Weather Observations: Temp.'�(°F) Sampler Signature Stabilization Test Ackt, l F x a,Do;)4�i Time Purged Temp. CC) 1 Diss Oxy. (mg/L) 3, Spec. (us) pH (s.u.) ReDox (mV) Turbidity (ntu) o ume removed (gallons/mis/ L Water level (ft) Other �' B.1nafyEFeat` Document Name: Field data Sheet Document Number: F-CAR-FLD-001-rev.03 Oct-'';) y 54 cc-D (-pcjid, 30�) Name and Affiliation Name and Affiliation (Inspector): tV We11In— forte Well ID: . U) Well Diameter: - Total Well Depth: _ft Static Water Level!_�ft Height of Water Column ft Purge Inforaratin L !ld Data Sheet Review: " i(j[?AfU Date: C e to ess Multi Factor": l*(R3dius/l2)2 x 114 x 7.491. Casing Volume: gallons Cal. 3 Volumes: gallons Pump Intake:_ ft Office By:. — Date Purged: — Start: Finish: Purge Rate: Purging Method:. � Total Volume Purged: allons mis (g / / L) Sampling Information Date Collected: —LgL'/ / �( Time Collected: I �10 (am/ m) Sampling Equipment Used: (;> M Bottle Type �—Instrument ID. ySt Preservati6n Analysis Required Field Measurements/Observations Sample Temp (aq; 1' \� P —� Timer Turbidity (ntu): , Q Diss Oxy (mg/L ` Time: b a C) Time: is a Q Fe 2+ mg/L:�__ (,G Specific Cond. uS : 4-e i Time: ( ) Time: )— 6 Res. Cl (mg/L)/(µg/L); Time:. Sample pH (s.u.): �_ Time: 1 G'a >_ Odor: �ec,&to -e Time: �� ReDox (mV): �1.5 Time: 16 No Appearance: ife cvj General/Weather Observations: L1rktab� e: ReDox (EH value):YSI PTOPlus +200mV S41 S Genera Other: Time: Temp.(-F) Dxunient Name: Field data Sheet Date aeesLt7tytioat f �ocumeuC NumtmT. P-CAR_FhD-001,,0.3 Issuing. Autho Field Data Sheet Client: Location;_ Sh ¢ 11 e v o Project #: l� Nameand Affiliation (Sampler(s):�� -R(,,La Name and Affiliation (Inspector): N(�` cell Pield Data Sheet Review: l�rz, (Zt Well Information Date:.i��I Well ID:. a LU lVa l bAakr t as re . Well Diameter: Co Total Well Depth: — ft Multi Factor*: Static Water Level: ( (Radius/12)2x314 x 7.A81 ' it Casing Volume; — gallons Height of Water Column: ft Cal. 3 Volumes gallons .S_Go. A-�i-�-eLt=oet.a0 c� S4 By: Intake: __fk Purrze Information1'ronp: Date Purged: / - ! Start: Finish: Purge Rate: Purging Method: Total Volume Purged: (gallonslullsl'L) Sampling Information Date Collected: tot /mil 1 Sampling Equipment Used: Bottle Type field Measureme ts/pbbservat;n ,_ Time Collected: 13� ---111._._ (am Preservation Analysis Required )`)A1 � 1 V Sample Temp (eC): --A;!,Time; ! 7rL —Turbidity (zltu): S Time; Diss Oxy (mglL): l 1 • Time: Fe 2+ mg/l� Specific Cond. (uS); y—Time: Sample pH (s.u.):� Time:. Res. Cl I � Odor._. _ iJ . ----Time: ..._ � �n..— ReDox (mV): S�3. /I -- e):ycTime: I t Q Appearance. Cla,,t w/ ���cul«} tme: I 1 Q ReI7ox (EH vahta):YSI proPlus +20dmv G Genera Other: Time: t/tNeatherQbservations: �VS,to z%S' �,5�43-'AbCTN Sampler Time Temp, Diss Oxy, Spec. Vo nine Purged CC) (mg/I) Cond. pH (s.u.) ReDox Turbidity removed Water (US) (mv) (ntu) (gallons/cols/ 1:1 (ft) Other Document Name: Field data Sheet. hate Issued: March 8, 2p1low z aCeAna(ytisal' P: ge; 1 of r Document Number. F-CAR-FLD-001-rev.03 Issuu,g Authority: Pace Huntersville Quality Office Field Data Sheet Name and Affillation (Sampler(s): jU-?caCpAnatc,(sCv�l Name and Affiliation (Inspector): hj\ A Well Information Well ID; 5In1 - D Well f arkscl• Well Diameter: Total Well Depth: — ft Static Water 'Level: � ft Height of Water Column: ft Pic ad Data Sheet Review: Ivl2g1V Date: 10/0i/�l C au1 ess Steel) Multi Factor*: [*(Radius/12)2 x 3,14 x.7,481 Casing Volume: gallons Cal, 3 Volumes: gallons Pump Intake. It Purge Information Date Purged: // — Starts Finish: Purge Rate: CX3 By. Nk Purging Method: Total Volume Purged; (gallons/m1s/1;) Sampling information Date Coilected:Aq._/�W_:)�k Time CollectedjQ (-�, am pm) Sampling, Equipment Used: (2 rr % Instrument ID: iS�Gr S i.a_�.t (1CC�w r9W t� c� Bottle Type Preservation Analysis Required I -�'—C1rwL � ..Rg_(IS-........ C�n,L ..rc�f� I-I-C.( Q-ul Ne( �i�Y C)tn�Cn v Field Measurements/Observations Sample Temp CC): ) �1 t _Time;�� !ICE _ Turbidity (ntu): •_ Time: I o 1 [\ DissOxy (mg/L):— Time: I 1�k(4n Fe2+mg/L; NZ Time: I Q)I I CI Specific Cond. (uS): ) 6 ] ,-)- Time: J qy 1(Res- Cl (nig/L)/(µg/L): '— Ti1ue; Sample pH(s.u.): g ___.... Time: I Q,An Odor:__-- _/Q)-�> ___—Time:..I ReDox (mV): % Time:- I'"I I\ Appearance: C � Time: 1 Q� ReDox (EH value):YSI ProPlus +200mV DLb(7 .a Other: Time: General/WeatherObservations_ %.,pS rr, s 1N.-8L�3��at'� Sampler Signature Stabilization Test Trine Purged Temp. u (C) Diss Oxy: (mg/L) Spec. Cond. (us) pH (s.u.) ReDox (mV) Turbidity (ntu) Volume removed (gallons/m1s/ Water Level (ft) Other -Z,L or z Document Name Field data Sheet Date Issued: March 8, 2019. a�ieRttaij?�Lk71 Page: 1 of i _ } Document Number F CAR-FL.[i-p0l-rev.43 Issuing Authority: Pace Huntersville Quality Office Field Data Sheet Client:_. L"ELocation:'P at -VC Project#:5bnrornb�(a1w' Name and Affiliation (Sampter(s): v nLkcrl Field Data Sheet Review: Name and Affiliation (Inspector)i N 1R f01 Ili WellInfonnation Date: jolt By: Well ID: S IN Well Diameter: �ctrt Af} (n�rr Total Well Depth: ` It Multi Factor*: ((Radius/12)2 x31t4 x 7. ks) Static Water Level: — £t Casing Volume: — gallons Height of Water Column: ft Cal.3 Volumes: — gallons Punip Intake: `� ft Purge Information h DatePuuged:'r —/ —Start:Finish: -- Purge Rate: Purging Method:___________— Total Volume Purged: I(gallons/mis/I.) Sampling Information Date CaBected:_jq—f Time Collected;_, b )�_ (an pm Q 0 . Z)oyt S� Sampling Equipment Used: Vrrnl Instrument ID:_ y�C nnl�rr y_. �[vqt eL)Tt,,,#.3n Bottle Type Field Measurements/Observations Preservation 14} j o? `-1-c1 Analysis Required A(in-r If x [.tin:11'11AI Sample Temp (aC): _� Cf •� _Time:�..�..a: _Turbidity (ntu): Time: i 6� Diss Oxy (mg/L): C Time., D��_ Fe 2+ mg/ L: /yin Time: l b J-�_ Specific Cond. (uS): Time: l bat Res. CI (mg/L)/(itg/L): Time: Sample pH (s,u); ` Ci_..._-. _. Time: Odor:----- 1`._'�2..-._ —Time:..._tr'-- ReDox (mV): Q) Time: t 6a Appearance: 1 I'ime: GaS ReDox (EH value):YSI ProPlus +200mV 3Q (fib Other: Time: General/WeatherObservations: Temp _'�(°17) Sampler Signature Stabilization Test Time Purged Temp. C) Diss Oxy. (ing/L) Spec. Cond. (us) pH (s.u.) ReDox (mV) Turbidity (ntu) Volume removed (gallons/mis/ L Water level (ft) ether )� l0 1 .. r 06Analytica! � i� Document Name Field data Sheet Date Issued: March S, 2019: Pager I of Document Number FChR-CAR Issuing Authmity� Pace Huntersville Quality Office Field Data Sheet Aske Ut Lin A-)C, Name and Affiliation (Sampler(s): �Z- bate &nj9 Cab( Field Data Sheet Review; Name and Affiliation (Inspector): 1 A ia(2y 12t Date: Well Information I to/dtl! a1 Well ID: S w - Well Diameter: ess eel) Total Well Depth: it Multi Factor*; (+(Radius/12)2x3.14x7.18] Static Water Level: ft Casing Volume: gallons Height of Water Column: ft Cal. 3 Volumes: gal lorts A, k-e LP OcOODl IS11 By: W ?4_ Pump Intake: ft Purge Information Date Purged: — // Start: Finish: _ Purge Rate: — Purging Method:--- Total Volume Purged: — (gallons/cols/L) Sampling Information (6Qq Date Collected:10 / 'a i Time Collected: A (am pn ) vF �bcl, Sampling Equipment Used:— 6),,�e)n Instrument ID:_ �/ S Q colt u sy}a�M c of v at3t �� Bottle Type �-a-SQML "lQNL-act; �-t-lQrvL vea�y Preservation HNb2 Analysis Required An r. rnZ (f I ................... _ �d::1 V f)r I K (J" 0Y&_R_ Field Measurements/Observations Sample Temp CC): (3,�1 Tillie:�%Q 22 nn Turbid! ty(ntu): Time: IGLZ)O Diss Oxy (mg/L): FJ_ Time: ) 6 0 0 Fe 2+ mg/ Li /U1 Time: I.6 0 0 Specific Cond. (uS): I S h Tillie: t b00 Res. Cl (Diig/Lu(µg/ L): _'Time: Sample pH(s.u.): __...... ..Time:. 16Q0, Odor :—._._--- --- ---Time:.__�0 ,.._. ReDox (mV): 7 Time: 1 6 00 Appearance: GLer/ Time: ) 600 ReDox (EH value):YSIProPlus+200mV, GeneraVWeather Observations: L,dC4,100.4 q, j ""o Sampler Signature Stabilization Test Tillie: -- F5M,^ C—D 1z JLL,J Wind —(mph) Time Purged Temp. ('C) Diss Oxy. (mg/L) Spec.. Cond. (u5) pH (s.u.) ReDox (mV) Turbidity (ntu) Vo ume removed (gallons/mis/ L Water level (ft) Other ___--- ---------- ____-__.__ Document Name: Field data Sheet Hate Issued! March8; 2014 _,_ Z/Inalytical Page. 1 of t Document Number: F-CAR-FLD-001-mv;03 Issuing. Authority: Pace Hmrtersville Quality Office Name and Affiliation(Sampler(s): ,ZTZ- } t x ,q L1,,{,c�.\ Name and Affiliation (Inspector): n t 11) Well Information Well ID: / kVan T acka . t.1C Well Diameter: Total Well Depth: Static Water Level: £t Height of Water Column:—' ft aid Data Sheet Review: icfl n17I Date: h(d`1IJI el) Multi Factor*: I" (Radiva/ lm2 x 3,14 x.7.481 Casing Volume: gallons Cal. 3 Volumes: gallons �] C1� By. N� Pump Intake: ft Puree Information Date Purged: Start: — Finish: Purge Rate: Purging Method:_ -- Total Volume Purged: (gallonsJmLsJh) Sampling Information Date Collected:/�/a Time 0/p Collected:_ ) 1��i_.__ { n to Sampling Equipment Used: 6 f,, 6 InstrumentID: Bottle Type Preservation Anal sr 0 d �Qr✓\- `1 rJ.wL�n aRr, Anal — is Field Measurements/Observations equxre aPoT_ yo_c- 1, �tD-, pxr— Sample Temp (°C): _ (Q Time_U30 _ Turbidity (ntu): _ Time: I 17) C)� Diss Oxy (mg/L): Time: _ Fe 2+ mg/L: , D Time: 1 I (l Specific Cond. (uS): ]C 7, �y —_ Time: Res. Cl (mg/L)/(ug/L): .line: "— Sample f 130 Odor: _ ReDox (mV): 6 `i •6 Time: (I Zi 0 Appearance _( I o Finite: ReDox (EH value):YSI ProPlus,+200mV-_aLT Other: Time: General/Weather Observations: 1, O'�, rr, ,. -jr • �17 Temp.S�A__,f°ri Sampler Signature Stabilization Test Time Purged Temp. (eC) Diss Oxy (mg/I.) Spec. (us)Cond PH (s.u.) ReDox (111V) Turbidityremoved (ntu) Vo tune (gallons/cols/ L Water level (ft) Offler IQ 1 Ihmmnent Name: Field data Sheet bate Issued: March 6, 2019 �eA+taly11sa1 Pa e: 1 of f ' Document Number: F-CAR-17I.1)-001-rev.03 Issuing. Authority: Pace Htmtersville Quality' Office 1J C Name and Affiliation (Sampler(s): �— {mac cn Aczj N(a\ Field Data Sheet Review: Name and Affiliation (Inspector): _} J i0f2`lt?I Well Information Date: lol zq jZ,] Well ID: S(,J Well i nrt d( v's zo ,` Hubtu tuunt) Well Diameter: C Total Well Depth: ft Multi Factor*: ((Radius/12)4x 3i14x 7.481 Static Water Level £b Height of Water Column: "— ft Casing Volume: gallons Cal.3 Volumes gallons Pump Intake: ft Purge Information Date Purged: -- J= f — Start : Finish, Forge Rate: Ac. &_ . L.r 0ck,3r.Dl S1 CTS By: RM e Purging Method:_ Total Volume Purged: {gallonsf a lsji:,} Sampling Information Date Collected:�(L/(_ Time Collected: `� am pm) Sampling Equipment Used: instrument ID: j tV(rrrv'1 —", �( Bottle Type Preservation Analysis Required H'joz =rx��rlt 140 - d� _gym....._ _........_ ADp 3 �nC1M a a; I f( i, �t D Like z Field Measuremen!g Observations Sample Temp CC): j(13Time.,_ 0 _Turbidity (ntu): D.3 Time;L- Diss Oxy (mg/L): b Time: 0'AW— Fe 2+mgJL: fJ' Time: 44(T Specific Cond. (uS): ) e-14r'1 Time: n SC Res. Cl (nig/L)/(µg/L): — :Time: Sample pH (s:u): 7• a __..., Time: O S {C Odor:;_..._ 711D...__--.___—Time:..._SL�V( ... _ ReDox (mV); Time: 0 A V$ Appearance: C 1Q.i?Y Time: Oa ReDox (EH value):YSl ProPlus +2OOmV D � Other: Time: General/Weather Observations: rnr,rrl 2 2 Sampler Signature Stabilization Test Purged Temp. (°C) Diss Oxy: (mgJL) Spec,aReDoxTurbidity (use. PH (au.)(gal1onsjmisj Vo Lime, removed Water level (ff)L Document Narne: Field data Sheet Date Issued March &, 2019 2CCflih2lytlCCt Page:. 1 of—) Dmument Number F-CAR-FI:.D-001-rev.03 Issuing,Authority: Pace Htmtersville Quality Office Name and Affiliation (Sampler(s):. an_ P,, �nr c cif Field Data Sheet Review: Name and Affiliation (Inspector): r`1 Date: iGJ2IR21 Well Information O 641 ja Well ID: Cv1J Well Diameter: ee aut e, - teel) Total Well Depth; — It Multi Factor*: — r(Radiu5/12)2 x 114 x T481 Static Water Level: ft Casing Volume: gallons Height of Water Column: ft CaL 3 Volumes; gallons Pump Intake: — —it Purge' Information Date Purged: '--'" // "'—' Start : Finish: Purge Rate: By: t'Tl3 Purging Method. Total Volume Purged: (gallons/nits/L) Sampling Information Date CoI1ected:_k_.yi_/X/ a-1 (- 'rime Collected: _Q� �.._ am/ptrl} Sampling Equipment Used: V °� Instrument ID: YSr (A4j* Bottle Type Preservation Analysis Required 6/N111 (S ......... Field MeasurenxentslObservations Sample Temp ('C): 1 �Y. Timer( i_ Turbidity (ntu): Diss Oxy (mg/L): �''�� Time: C1� a Cl Fe 2+ mg/ L: 1�%i Time: Specific Cond. (uS); u��Time: OCl�C Res. Cl (nog/L)/(µg/L): 'rime: `— Sample pH (s.u.): �,,. -__ - Time:. �- 0 F C1 pp ReDox(mV): 'p�-jo Time: OS' 0 Appearance C Vca,a(' 'lime:. 0!x;'�Q ReDox (EH value):YSI ProPlus #200mV 1 i� D • ( Other: Time: — General/Weather Sampler Signature Stabilization Test �tV Temp.. L4\ (°F) W Purged Pingeged Temp. CC) Diss Oxy. (mg/L) Spec. (US) (s ppH.u.) ReDox OTIV) Turbidity (ntu) Vo me removed (gallons/mis/ Water level (ft) Other ., r1CeA/ts11yliCal t 713 LE Dcmurnant Name: Field data Sheet. Document Number. F-CAR-FLD-001-rev.03 Name and Affiliation (Sampler(s): G'U'- -T0. C-e Name and Affiliation (Inspector): V a- � Weli Infuriation Well TD: 5 L -- Locked: We ameter: Z� e, Constr on: Total Well D i If Multi Factor*; Date Issued: Page; udhodty:.pai of 3" K e014 Data Sheet Review: Date: laf2L1l� loM)'I ( YES / NO / Flushm (PVC/Steel/Stainless Steel) Static Water Level: If Casing Volume: Height of Water Column: ft Purge Information —�— Date Purged:_// Purging 1"(Radius/ 12)2:x 3,14 x 7,481 gallons Pump Intake: If Finish: Purge Rate: of I By: i3 (gallons/ailsIL) Sampling Information DateCollected: / a / 2 / 2/ Time Collected: =--- (am/pm) Sampling Equipment Used: qL /o InstrumentID:7g'#yzo3 Tek463S5 Bottle Type Preservation Analysis Required Sample Temp .Turbidity (ntu): Diss Oxy (mg/L), _ Fe 2+ mg/L:_ Specific Coud. (uS): Time: es (mg/L Sample pH ReDox (mV): Time: Appearance: _ ReDox (EH value):YSI ProPlus +200MV Other: General/Weather Observations:____3 Sampler Signature Stabilization Test Time: Time: Time: 2- lLJ Temp. So (°F) l0-26-21 Time Purged Temp. (aC) Oxy. (mg/L) Spec. Cond. (uS pH (s.u.) ReDox (mV) Turbidity (mu) Volume removed (gallons/mis/ L Water level (ft) Other J`e n"C O.c1-.3Q-I 5.4 . ua vapallClC1: Total Well Depth: Static Water Level:_______- ___ft '-'eight of Water Column: ft Multi Factor*: r(Radius/12)2 x 3,14 x7.as] Casing Volume: gallons Cal.3 Volumes; gallons PurgePump Intake: _ft Information , ��olyyyy� Date PurgedS�--�-- .Start: Finish; Purge Rate: `--- Purging Method: Total Volume Purged: (gallons/ails/L) Sainuline Information Date Collected: iQ /—?I/ Time Collected: Sampling Equipment Used: Cgv-r (n -AT!"/pm) Instrument ID: `F— Serer,(.. * Bottle Type �--�—i:-a'� C11S crb rpwrs Preservation Analysis Re ' d ` Li Field Measurements/Observations 1—I ✓v IJ I�t1� �C t quire At�nT V 3C Sample Temp (°C): 1, Time: S ._Turbidity (ntu): c� ,(� Time: Diss Oxy (mg/L): � , Time: I $ S Fe 2+ mg/ Li 1 Specific Cond. (uS); -- --------T e: Time: 1 Res. Cl Sample pH (s.u.): `�f31 ._.._ _Timer I —_Odor: ---- .._Nth Time: Time: 1 Appearance: C"0.0 ReDox (EH value):Y(3l proptus +200mV �Sj V ---rime: General/Weather Observations: Other: (�C i J. ? Sampler /rainy) Temp(. Time Temp. Diss Oxy. SpeC' me Purged (°C) Cond. pH (s.u.) ReDox Turbidij7o ved Water(US) (inV) (ntu)/mis/ level (ft) Other 1 .n APPENDIX B LABORATORY ANALYTICAL DATA - PACE ANALYTICAL SERVICES, LLC. 0 aceAnalytical Report of Analysis Bunnell-Lammons Engineering, Inc. 6004 Ponders Court Greenville, SC 29615 Attention: Andy Alexander Project Name: Active Buncombe County Landfill MW Project Number: 9378-26A Lot Number:WJ30017 Date Completed:12/07/2021 12/13/2021 10:58 AM Approved and released by: Project Manager II: Lucas Odom pCCgF� 24r�A SOA ANSI National Accreditation Board A C C R E D I T E D TESTING LABORATORY The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 1 of 149 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative Bunnell-Lammons Engineering, Inc. Lot Number: WJ30017 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved The NELAC Institute (TNI) standards, the Pace Analytical Services, LLC ("Pace") Laboratory Quality Manual, standard operating procedures (SOPS), and Pace policies. Any exceptions to the TNI standards, the Laboratory Quality Manual, SOPs or policies are qualified on the results page or discussed below. Pace is a TNI accredited laboratory; however, the following analyses are currently not listed on our TNI scope of accreditation: Biological Tissue: All, Non -Potable Water: SGT-HEM EPA 1664B, Silica EPA 200.7, Boron, Calcium, Silicon, Strontium EPA 200.8, Bicarbonate, Carbonate, and Hydroxide Alkalinity SM 2320 B-2011, Fecal Coliform SM 9221 C E-2006 & SM 9222D-2006, Strontium SW-846 6010D, VOC SM 6200 B-2011, Drinking Water: VOC (excluding BTEX, MTBE, Naphthalene, & 1,2-dichloroethane) EPA 524.2, Solid Chemical Material: TOC Walkley-Black. If you have any questions regarding this report please contact the Pace Project Manager listed on the cover page. VOCs by GUMS The laboratory control sample (LCS) for analytical batch 21730 exceeded acceptance criteria for Acetone. This analyte is biased high but not detected in the samples affected. Due to the large number of spiked analytes, there is a high probability that one or more analytes will recover outside acceptance limits. The laboratory's SOP allows for 10% of analytes to recover marginally outside criteria. The following analytes recovered marginally outside LCS criteria: Acetone (141 %). The laboratory control sample (LCS) for analytical batch 22207 exceeded acceptance criteria for 2- Butanone. This analyte is biased high but not detected in the samples affected. Reanalysis of the following samples was performed outside of the analytical holding time for Vinyl Acetate with concurring results: WJ30017-001, WJ30017-002. The samples were not detected in the LOQ which is required for these samples during initial analysis. Reanalysis of the following samples was performed outside of the analytical holding time for 2-Butanone and Vinyl Acetate with concurring results: WJ30017-004, WJ30017-005, WJ30017-006, WJ30017-007, WJ30017-008, WJ30017-009, and WJ30017-010. The samples were not detected in the LOQ which is required for these samples during initial analysis. Metals by ICP The method blank associated with batch 21233 yielded a "J" value detection for Iron and the MB associated with batch 21241 yielded a "J" value detection for Zn. No corrective action is required as this is an estimated value recovered below the LOQ. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 whw.pacelabs.com Page 2 of 149 PACE ANALYTICAL SERVICES, LLC Sample Summary Bunnell-Lammons Engineering, Inc. Lot Number: WJ30017 Sample Number Sample ID Matrix Date Sampled Date Received 001 MW-17R Aqueous 10/27/20211025 10/29/2021 002 MW-17DR Aqueous 10/27/20210955 10/29/2021 003 MW-11 Aqueous 10/27/20211045 10/29/2021 004 MW-11D Aqueous 10/27/20211045 10/29/2021 005 MW-4D Aqueous 10/27/20211130 10/29/2021 006 MW-4 Aqueous 10/27/20211200 10/29/2021 007 MW-2D Aqueous 10/27/20211250 10/29/2021 008 MW-2 Aqueous 10/27/20211305 10/29/2021 009 MW-18 Aqueous 10/27/20211640 10/29/2021 010 Trip Blank Aqueous 10/27/2021 10/29/2021 011 MW-1D Aqueous 10/26/20210925 10/28/2021 012 MW-1 Aqueous 10/26/20211100 10/28/2021 013 MW-14D Aqueous 10/26/20211205 10/28/2021 014 MW-14 Aqueous 10/26/20211250 10/28/2021 015 MW-12D Aqueous 10/26/20211340 10/28/2021 016 MW-12 Aqueous 10/26/20211420 10/28/2021 017 MW-13D Aqueous 10/26/20211520 10/28/2021 018 MW-13 Aqueous 10/26/20211550 10/28/2021 019 MW-8 Aqueous 10/26/20211645 10/28/2021 020 MW-8D. Aqueous 10/26/20211700 10/28/2021 021 MW-10 Aqueous 10/28/20211010 10/30/2021 022 MW-1OD Aqueous 10/28/20211045 10/30/2021 023 MW-3R Aqueous 10/28/20211240 10/30/2021 024 MW-7 Aqueous 10/28/20211350 10/30/2021 025 MW-5D Aqueous 10/28/20211200 10/30/2021 026 MW-5 Aqueous 10/28/20211235 10/30/2021 027 MW-6 Aqueous 10/28/20211520 10/30/2021 (27 samples) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 3 of 149 PACE ANALYTICAL SERVICES, LLC Detection Summary Bunnell-Lammons Engineering, Inc. Lot Number: WJ30017 Sample Sample ID Matrix Parameter Method Result Q Units Page 001 MW-17R Aqueous Alkalinity @ pH 4.5 su SM 232013- 79 mg CaCO3/L 10 001 MW-17R Aqueous Chloride 9056A 3.2 mg/L 10 001 MW-17R Aqueous Sulfate 9056A 33 mg/L 10 001 MW-17R Aqueous TDS SM 2540C- 150 mg/L 10 001 MW-17R Aqueous Barium 6020B 64 ug/L 12 001 MW-17R Aqueous Copper 6020B 7.0 ug/L 12 001 MW-17R Aqueous Iron 6020B 290 ug/L 12 001 MW-17R Aqueous Manganese 6020B 55 ug/L 12 001 MW-17R Aqueous Nickel 6020B 22 ug/L 12 001 MW-17R Aqueous Zinc 6020B 9.0 J ug/L 12 002 MW-17DR Aqueous Alkalinity @ pH 4.5 su SM 232013- 120 mg CaCO3/1- 13 002 MW-17DR Aqueous Chloride 9056A 3.9 mg/L 13 002 MW-17DR Aqueous Sulfate 9056A 25 mg/L 13 002 MW-17DR Aqueous TDS SM 2540C- 190 mg/L 13 002 MW-17DR Aqueous Barium 6020B 51 ug/L 15 002 MW-17DR Aqueous Iron 6020B 200 ug/L 15 002 MW-17DR Aqueous Manganese 6020B 8.8 ug/L 15 003 MW-11 Aqueous Barium 6020B 64 ug/L 17 003 MW-11 Aqueous Copper 6020B 6.9 ug/L 17 003 MW-11 Aqueous Nickel 6020B 22 ug/L 17 003 MW-11 Aqueous Zinc 6020B 8.7 J ug/L 17 004 MW-11D Aqueous Barium 6020B 64 ug/L 19 005 MW-41D Aqueous Barium 6020B 110 ug/L 21 005 MW-41D Aqueous Chromium 6020B 1.4 J ug/L 21 005 MW-41D Aqueous Cobalt 6020B 11 ug/L 21 005 MW-41D Aqueous Copper 6020B 3.2 J ug/L 21 005 MW-41D Aqueous Lead 6020B 0.46 J ug/L 22 005 MW-41D Aqueous Nickel 6020B 34 ug/L 22 005 MW-41D Aqueous Zinc 6020B 14 ug/L 22 006 MW-4 Aqueous Barium 6020B 40 ug/L 24 006 MW-4 Aqueous Chromium 6020B 9.6 ug/L 24 006 MW-4 Aqueous Nickel 6020B 7.8 ug/L 25 006 MW-4 Aqueous Zinc 6020B 7.7 J ug/L 25 007 MW-21D Aqueous Barium 6020B 48 ug/L 27 007 MW-21D Aqueous Vanadium 6020B 3.2 J ug/L 27 008 MW-2 Aqueous Barium 6020B 76 ug/L 29 008 MW-2 Aqueous Nickel 6020B 5.7 ug/L 29 008 MW-2 Aqueous Vanadium 6020B 2.8 J ug/L 29 009 MW-18 Aqueous Alkalinity @ pH 4.5 su SM 232013- 79 mg CaCO3/1- 30 009 MW-18 Aqueous Chloride 9056A 1.7 mg/L 30 009 MW-18 Aqueous Sulfate 9056A 30 mg/L 30 009 MW-18 Aqueous TDS SM 2540C- 150 mg/L 30 009 MW-18 Aqueous Barium 6020B 12 ug/L 32 009 MW-18 Aqueous Chromium 6020B 5.4 ug/L 32 009 MW-18 Aqueous Copper 6020B 1.4 J ug/L 32 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 4 of 149 Detection Summary (Continued) Lot Number: WJ30017 Sample Sample ID Matrix Parameter Method Result Q Units Page 009 MW-18 Aqueous Iron 6020B 300 ug/L 32 009 MW-18 Aqueous Manganese 6020B 24 ug/L 32 009 MW-18 Aqueous Nickel 6020B 3.7 J ug/L 32 009 MW-18 Aqueous Zinc 6020B 3.6 J ug/L 32 011 MW-1 D Aqueous Alkalinity @ pH 4.5 su SM 232013- 83 mg CaCO3/1- 35 011 MW-1D Aqueous Chloride 9056A 2.5 mg/L 35 011 MW-1D Aqueous Sulfate 9056A 41 mg/L 35 011 MW-1D Aqueous TDS SM 2540C- 180 mg/L 35 011 MW-1D Aqueous 2-Butanone (MEK) 8260D 2.3 J ug/L 35 011 MW-1D Aqueous Antimony 6020B 0.66 J ug/L 37 011 MW-1D Aqueous Barium 6020B 31 ug/L 37 011 MW-1D Aqueous Iron 6020B 160 B ug/L 37 011 MW-1D Aqueous Lead 6020B 0.37 J ug/L 37 011 MW-1D Aqueous Manganese 6020B 14 ug/L 37 011 MW-1D Aqueous Nickel 6020B 4.5 J ug/L 37 011 MW-1D Aqueous Zinc 6020B 5.5 J ug/L 37 012 MW-1 Aqueous Alkalinity @ pH 4.5 su SM 232013- 59 mg CaCO3/1- 38 012 MW-1 Aqueous Chloride 9056A 6.2 mg/L 38 012 MW-1 Aqueous Sulfate 9056A 20 mg/L 38 012 MW-1 Aqueous TDS SM 2540C- 140 mg/L 38 012 MW-1 Aqueous Barium 6020B 140 ug/L 40 012 MW-1 Aqueous Chromium 6020B 2.3 J ug/L 40 012 MW-1 Aqueous Iron 6020B 190 B ug/L 40 012 MW-1 Aqueous Manganese 6020B 7.5 ug/L 40 012 MW-1 Aqueous Nickel 6020B 2.7 J ug/L 40 012 MW-1 Aqueous Vanadium 6020B 3.7 J ug/L 40 012 MW-1 Aqueous Zinc 6020B 7.5 J ug/L 40 013 MW-14D Aqueous Alkalinity @ pH 4.5 su SM 232013- 140 mg CaCO3/1- 41 013 MW-14D Aqueous Chloride 9056A 4.1 mg/L 41 013 MW-14D Aqueous Sulfate 9056A 31 mg/L 41 013 MW-14D Aqueous TDS SM 2540C- 210 mg/L 41 013 MW-14D Aqueous Barium 6020B 8.0 ug/L 43 013 MW-14D Aqueous Iron 6020B 240 B ug/L 43 013 MW-14D Aqueous Lead 6020B 0.39 J ug/L 43 013 MW-14D Aqueous Manganese 6020B 31 ug/L 43 013 MW-14D Aqueous Zinc 6020B 8.8 J ug/L 43 014 MW-14 Aqueous Alkalinity @ pH 4.5 su SM 232013- 65 mg CaCO3/1- 44 014 MW-14 Aqueous Chloride 9056A 2.5 mg/L 44 014 MW-14 Aqueous Sulfate 9056A 21 mg/L 44 014 MW-14 Aqueous TDS SM 2540C- 140 mg/L 44 014 MW-14 Aqueous Barium 6020B 50 ug/L 46 014 MW-14 Aqueous Iron 6020B 150 B ug/L 46 014 MW-14 Aqueous Manganese 6020B 4.0 J ug/L 46 014 MW-14 Aqueous Nickel 6020B 2.8 J ug/L 46 015 MW-12D Aqueous Alkalinity @ pH 4.5 su SM 232013- 170 mg CaCO3/1- 47 015 MW-12D Aqueous Chloride 9056A 12 mg/L 47 015 MW-12D Aqueous Sulfate 9056A 66 mg/L 47 015 MW-12D Aqueous TDS SM 2540C- 290 mg/L 47 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 5 of 149 Detection Summary (Continued) Lot Number: WJ30017 Sample Sample ID Matrix Parameter Method Result Q Units Page 015 MW-12D Aqueous 1,4-Dioxane 8260D (SIM) 1.9 J ug/L 47 015 MW-12D Aqueous Barium 6020B 63 ug/L 49 015 MW-12D Aqueous Cobalt 6020B 2.1 J ug/L 49 015 MW-12D Aqueous Iron 6020B 290 B ug/L 49 015 MW-12D Aqueous Manganese 6020B 470 ug/L 49 015 MW-12D Aqueous Nickel 6020B 3.6 J ug/L 49 016 MW-12 Aqueous Alkalinity @ pH 4.5 su SM 2320B- 240 mg CaCO3/1- 50 016 MW-12 Aqueous Chloride 9056A 38 mg/L 50 016 MW-12 Aqueous Sulfate 9056A 290 mg/L 50 016 MW-12 Aqueous TDS SM 2540C- 680 mg/L 50 016 MW-12 Aqueous 1,4-Dioxane 8260D (SIM) 2.8 J ug/L 50 016 MW-12 Aqueous Acetone 8260D 8.1 JL ug/L 50 016 MW-12 Aqueous Tetrahydrofuran 8260D 3.4 J ug/L 51 016 MW-12 Aqueous Mercury 7470A 0.00023 mg/L 52 016 MW-12 Aqueous Barium 6020B 110 ug/L 52 016 MW-12 Aqueous Cadmium 6020B 0.40 J ug/L 52 016 MW-12 Aqueous Chromium 6020B 1.5 J ug/L 52 016 MW-12 Aqueous Cobalt 6020B 29 ug/L 52 016 MW-12 Aqueous Copper 6020B 19 ug/L 52 016 MW-12 Aqueous Iron 6020B 130 B ug/L 52 016 MW-12 Aqueous Manganese 6020B 2500 ug/L 52 016 MW-12 Aqueous Nickel 6020B 34 ug/L 52 016 MW-12 Aqueous Zinc 6020B 6.4 J ug/L 52 017 MW-13D Aqueous Barium 6020B 230 ug/L 54 017 MW-13D Aqueous Cobalt 6020B 21 ug/L 54 017 MW-13D Aqueous Nickel 6020B 9.6 ug/L 54 018 MW-13 Aqueous Barium 6020B 200 ug/L 56 018 MW-13 Aqueous Cobalt 6020B 26 ug/L 56 018 MW-13 Aqueous Lead 6020B 0.26 J ug/L 56 018 MW-13 Aqueous Nickel 6020B 6.3 ug/L 56 018 MW-13 Aqueous Zinc 6020B 9.8 J ug/L 56 019 MW-8 Aqueous Antimony 6020B 1.6 J ug/L 58 019 MW-8 Aqueous Barium 6020B 140 ug/L 58 019 MW-8 Aqueous Chromium 6020B 2.7 J ug/L 58 019 MW-8 Aqueous Copper 6020B 1.7 J ug/L 58 019 MW-8 Aqueous Lead 6020B 0.26 J ug/L 58 019 MW-8 Aqueous Nickel 6020B 3.1 J ug/L 58 019 MW-8 Aqueous Zinc 6020B 16 ug/L 58 020 MW-81D. Aqueous Barium 6020B 170 ug/L 60 020 MW-81D. Aqueous Chromium 6020B 1.4 J ug/L 60 020 MW-81D. Aqueous Nickel 6020B 4.3 J ug/L 60 020 MW-81D. Aqueous Zinc 6020B 4.7 J ug/L 60 021 MW-10 Aqueous Xylenes (total) 8260D 0.51 J ug/L 62 021 MW-10 Aqueous Barium 6020B 140 ug/L 62 021 MW-10 Aqueous Chromium 6020B 3.9 J ug/L 62 021 MW-10 Aqueous Cobalt 6020B 3.3 J ug/L 62 021 MW-10 Aqueous Nickel 6020B 11 ug/L 62 021 MW-10 Aqueous Vanadium 6020B 2.6 J ug/L 63 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 6 of 149 Detection Summary (Continued) Lot Number: WJ30017 Sample Sample ID Matrix Parameter Method Result Q Units Page 021 MW-10 Aqueous Zinc 6020B 4.6 J ug/L 63 022 MW-1OD Aqueous 1, 1 -Dichloroethane 8260D 0.84 J ug/L 64 022 MW-10D Aqueous cis- 1,2-Dichloroethene 8260D 0.47 J ug/L 64 022 MW-1OD Aqueous Barium 6020B 30 ug/L 65 022 MW-1OD Aqueous Chromium 6020B 3.8 J ug/L 65 022 MW-1OD Aqueous Nickel 6020B 12 ug/L 65 023 MW-3R Aqueous Barium 6020B 64 ug/L 68 023 MW-3R Aqueous Chromium 6020B 3.0 J ug/L 68 023 MW-3R Aqueous Nickel 6020B 3.1 J ug/L 68 023 MW-3R Aqueous Vanadium 6020B 4.3 J ug/L 68 023 MW-3R Aqueous Zinc 6020B 5.9 J ug/L 68 024 MW-7 Aqueous Barium 6020B 180 ug/L 70 024 MW-7 Aqueous Chromium 6020B 2.7 J ug/L 70 024 MW-7 Aqueous Cobalt 6020B 1.8 J ug/L 70 024 MW-7 Aqueous Nickel 6020B 15 ug/L 70 024 MW-7 Aqueous Zinc 6020B 3.7 J ug/L 70 025 MW-51D Aqueous Barium 6020B 74 ug/L 72 025 MW-51D Aqueous Chromium 6020B 5.3 ug/L 72 025 MW-51D Aqueous Nickel 6020B 5.5 ug/L 72 025 MW-51D Aqueous Zinc 6020B 2.9 J ug/L 72 026 MW-5 Aqueous Barium 6020B 130 ug/L 74 026 MW-5 Aqueous Chromium 6020B 5.7 ug/L 74 026 MW-5 Aqueous Lead 6020B 0.33 J ug/L 74 026 MW-5 Aqueous Nickel 6020B 8.7 ug/L 74 026 MW-5 Aqueous Vanadium 6020B 2.8 J ug/L 74 026 MW-5 Aqueous Zinc 6020B 5.1 BJ ug/L 74 027 MW-6 Aqueous Barium 6020B 50 ug/L 76 027 MW-6 Aqueous Zinc 6020B 3.0 BJ ug/L 76 (169 detections) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 7 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-001 Description: MW-17R Matrix: Aqueous Date Sampled:10/27/2021 1025 Date Received:10/29/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 11/07/2021 0421 AAB 21752 1 (Chloride) 9056A 1 11/02/2021 1640 AMR 21118 1 (Sulfate) 9056A 1 11/02/2021 1640 AMR 21115 1 (TDS) SM 2540C-2011 1 11/02/2021 1916 MOM 21024 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 79 20 20 mg CaCO3/L 1 Chloride 9056A 3.2 1.0 0.25 mg/L 1 Sulfate 9056A 33 1.0 0.25 mg/L 1 TDS SM 254OC-2011 150 25 25 mg/L 1 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/03/2021 0245 JWO 21040 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 81 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/20211809 CAW 21793 2 5030B 8260D 1 11/12/20211224 CAW 22328 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 8 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-001 Description: MW-17R Matrix: Aqueous Date Sampled:10/27/2021 1025 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/20211809 CAW 21793 2 5030B 8260D 1 11/12/20211224 CAW 22328 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 9 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-001 Description: MW-17R Matrix: Aqueous Date Sampled:10/27/2021 1025 Date Received:10/29/2021 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 93 70-130 H 101 70-130 1,2-Dichloroethane-d4 114 70-130 H 106 70-130 Toluene-d8 104 70-130 H 98 70-130 CVAA Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 11/09/2021 1550 CMS2 11/08/2021 1655 21630 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.00020 0.000091 mg/L 1 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/04/2021 1023 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 64 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 7.0 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 290 50 13 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 55 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B 22 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 9.0 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 10 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-002 Description: MW-17DR Matrix: Aqueous Date Sampled:10/27/2021 0955 Date Received:10/29/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 11/07/2021 0427 AAB 21752 1 (Chloride) 9056A 1 11/02/2021 1659 AMR 21118 1 (Sulfate) 9056A 1 11/02/2021 1659 AMR 21115 1 (TDS) SM 2540C-2011 1 11/02/2021 1916 MOM 21024 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 120 20 20 mg CaCO3/L 1 Chloride 9056A 3.9 1.0 0.25 mg/L 1 Sulfate 9056A 25 1.0 0.25 mg/L 1 TDS SM 254OC-2011 190 25 25 mg/L 1 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/03/2021 0309 JWO 21040 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 81 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/20211833 CAW 21793 2 5030B 8260D 1 11/12/20211247 CAW 22328 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 11 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-002 Description: MW-17DR Matrix: Aqueous Date Sampled:10/27/2021 0955 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/20211833 CAW 21793 2 5030B 8260D 1 11/12/20211247 CAW 22328 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 12 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-002 Description: MW-17DR Matrix: Aqueous Date Sampled:10/27/2021 0955 Date Received:10/29/2021 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 92 70-130 H 102 70-130 1,2-Dichloroethane-d4 115 70-130 H 107 70-130 Toluene-d8 105 70-130 H 99 70-130 CVAA Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 11/09/2021 1558 CMS2 11/08/2021 1655 21630 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.00020 0.000091 mg/L 1 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1847 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 51 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 200 50 13 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 8.8 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 13 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-003 Description: MW-11 Matrix: Aqueous Date Sampled:10/27/2021 1045 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/20210038 BBW 21870 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 14 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-003 Description: MW-11 Matrix: Aqueous Date Sampled:10/27/2021 1045 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/20210038 BBW 21870 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 114 70-130 Toluene-d8 104 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1822 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 64 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 6.9 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 22 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 8.7 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 15 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-004 Description: MW-11D Matrix: Aqueous Date Sampled:10/27/2021 1045 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/20210304 JWO 21878 2 5030B 8260D 1 11/12/20211310 CAW 22328 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 16 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-004 Description: MW-11D Matrix: Aqueous Date Sampled:10/27/2021 1045 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/20210304 JWO 21878 2 5030B 8260D 1 11/12/20211310 CAW 22328 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 89 70-130 H 94 70-130 1,2-Dichloroethane-d4 98 70-130 H 104 70-130 Toluene-d8 97 70-130 H 98 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1829 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 64 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 17 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-005 Description: MW-4D Matrix: Aqueous Date Sampled:10/27/2021 1130 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/03/2021 0334 JWO 21040 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 82 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0329 JWO 21878 2 5030B 8260D 1 11/12/20211334 CAW 22328 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L 2 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 18 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-005 Description: MW-4D Matrix: Aqueous Date Sampled:10/27/2021 1130 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/20210329 JWO 21878 2 5030B 8260D 1 11/12/20211334 CAW 22328 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 92 70-130 H 97 70-130 1,2-Dichloroethane-d4 98 70-130 H 103 70-130 Toluene-d8 99 70-130 H 97 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1831 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 110 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.4 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 11 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 3.2 J 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 19 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-005 Description: MW-4D Matrix: Aqueous Date Sampled:10/27/2021 1130 Date Received:10/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1831 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Lead 7439-92-1 6020B 0.46 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 34 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 14 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 20 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-006 Description: MW-4 Matrix: Aqueous Date Sampled:10/27/2021 1200 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/03/2021 0358 JWO 21040 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 81 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0354 JWO 21878 2 5030B 8260D 1 11/12/20211357 CAW 22328 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L 2 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 21 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-006 Description: MW-4 Matrix: Aqueous Date Sampled:10/27/2021 1200 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/20210354 JWO 21878 2 5030B 8260D 1 11/12/20211357 CAW 22328 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 93 70-130 H 99 70-130 1,2-Dichloroethane-d4 101 70-130 H 104 70-130 Toluene-d8 102 70-130 H 99 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1833 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 40 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 9.6 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 22 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-006 Description: MW-4 Matrix: Aqueous Date Sampled:10/27/2021 1200 Date Received:10/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1833 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Lead 7439-92-1 Nickel 7440-02-0 Selenium 7782-49-2 Silver 7440-22-4 Thallium 7440-28-0 Vanadium 7440-62-2 Zinc 7440-66-6 6020B ND 1.0 0.25 ug/L 1 6020B 7.8 5.0 1.3 ug/L 1 6020B ND 5.0 1.3 ug/L 1 6020B ND 1.0 0.25 ug/L 1 6020B ND 0.50 0.15 ug/L 1 6020B ND 5.0 2.5 ug/L 1 6020B 7.7 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 23 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-007 Description: MW-2D Matrix: Aqueous Date Sampled:10/27/2021 1250 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/20210419 JWO 21878 2 5030B 8260D 1 11/12/20211420 CAW 22328 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 24 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-007 Description: MW-2D Matrix: Aqueous Date Sampled:10/27/2021 1250 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/20210419 JWO 21878 2 5030B 8260D 1 11/12/20211420 CAW 22328 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 88 70-130 H 100 70-130 1,2-Dichloroethane-d4 95 70-130 H 106 70-130 Toluene-d8 96 70-130 H 99 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1835 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 48 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.2 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 25 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-008 Description: MW-2 Matrix: Aqueous Date Sampled:10/27/2021 1305 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0443 JWO 21878 2 5030B 8260D 1 12/03/20211125 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 26 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-008 Description: MW-2 Matrix: Aqueous Date Sampled:10/27/2021 1305 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0443 JWO 21878 2 5030B 8260D 1 12/03/20211125 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 89 70-130 H 94 70-130 1,2-Dichloroethane-d4 99 70-130 H 126 70-130 Toluene-d8 100 70-130 H 106 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1837 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 76 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.7 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 2.8 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 27 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-009 Description: MW-18 Matrix: Aqueous Date Sampled:10/27/2021 1640 Date Received:10/29/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 11/07/2021 0433 AAB 21752 1 (Chloride) 9056A 1 11/02/2021 1718 AMR 21118 1 (Sulfate) 9056A 1 11/02/2021 1718 AMR 21115 1 (TDS) SM 2540C-2011 1 11/02/2021 1916 MOM 21024 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 79 20 20 mg CaCO3/L 1 Chloride 9056A 1.7 1.0 0.25 mg/L 1 Sulfate 9056A 30 1.0 0.25 mg/L 1 TDS SM 254OC-2011 150 25 25 mg/L 1 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/03/2021 0422 JWO 21040 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 81 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/20210508 JWO 21878 2 5030B 8260D 1 12/03/20211150 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L 2 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 28 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-009 Description: MW-18 Matrix: Aqueous Date Sampled:10/27/2021 1640 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0508 JWO 21878 2 5030B 8260D 1 12/03/20211150 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 29 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-009 Description: MW-18 Matrix: Aqueous Date Sampled:10/27/2021 1640 Date Received:10/29/2021 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 92 70-130 H 87 70-130 1,2-Dichloroethane-d4 100 70-130 H 123 70-130 Toluene-d8 100 70-130 H 105 70-130 CVAA Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 11/09/2021 1601 CMS2 11/08/2021 1655 21630 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.00020 0.000091 mg/L 1 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1853 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 12 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.4 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.4 J 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 300 50 13 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 24 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B 3.7 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 3.6 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 30 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-010 Description: Trip Blank Matrix: Aqueous Date Sampled:10/27/2021 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0533 JWO 21878 2 5030B 8260D 1 12/03/20211216 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 31 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-010 Description: Trip Blank Matrix: Aqueous Date Sampled:10/27/2021 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0533 JWO 21878 2 5030B 8260D 1 12/03/20211216 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 92 70-130 H 91 70-130 1,2-Dichloroethane-d4 101 70-130 H 125 70-130 Toluene-d8 101 70-130 H 108 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 32 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-011 Description: MW-1D Matrix: Aqueous Date Sampled:10/26/2021 0925 )ate Received:10/28/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 11/07/2021 0439 AAB 21752 1 (Chloride) 9056A 1 11/02/2021 1737 AMR 21118 1 (Sulfate) 9056A 1 11/02/2021 1737 AMR 21115 1 (TDS) SM 2540C-2011 1 11/02/2021 1916 MOM 21024 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 83 20 20 mg CaCO3/L 1 Chloride 9056A 2.5 1.0 0.25 mg/L 1 Sulfate 9056A 41 1.0 0.25 mg/L 1 TDS SM 254OC-2011 180 25 25 mg/L 1 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0245 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 2.3 J 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 33 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-011 Description: MW-1D Matrix: Aqueous Date Sampled:10/26/2021 0925 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0245 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 93 70-130 1,2-Dichloroethane-d4 115 70-130 Toluene-d8 104 70-130 CVAA Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 11/09/2021 1604 CMS2 11/08/2021 1655 21630 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 34 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-011 Description: MW-1D Matrix: Aqueous Date Sampled:10/26/2021 0925 Date Received:10/28/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1302 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.66 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 31 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 160 B 50 13 ug/L 1 Lead 7439-92-1 6020B 0.37 J 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 14 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B 4.5 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.5 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 35 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-012 Description: MW-1 Matrix: Aqueous Date Sampled:10/26/2021 1100 )ate Received:10/28/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 11/07/2021 0444 AAB 21752 1 (Chloride) 9056A 1 11/02/2021 1834 AMR 21118 1 (Sulfate) 9056A 1 11/02/2021 1834 AMR 21115 1 (TDS) SM 2540C-2011 1 11/02/2021 1916 MOM 21024 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 59 20 20 mg CaCO3/L 1 Chloride 9056A 6.2 1.0 0.25 mg/L 1 Sulfate 9056A 20 1.0 0.25 mg/L 1 TDS SM 254OC-2011 140 25 25 mg/L 1 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0309 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 36 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-012 Description: MW-1 Matrix: Aqueous Date Sampled:10/26/2021 1100 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0309 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 91 70-130 1,2-Dichloroethane-d4 114 70-130 Toluene-d8 102 70-130 CVAA Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 11/09/2021 1606 CMS2 11/08/2021 1655 21630 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 37 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-012 Description: MW-1 Matrix: Aqueous Date Sampled:10/26/2021 1100 Date Received:10/28/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1304 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 140 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.3 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 190 B 50 13 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 7.5 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B 2.7 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.7 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 7.5 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 38 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-013 Description: MW-14D Matrix: Aqueous Date Sampled:10/26/2021 1205 )ate Received:10/28/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 11/07/2021 0450 AAB 21752 1 (Chloride) 9056A 1 11/02/2021 1853 AMR 21118 1 (Sulfate) 9056A 1 11/02/2021 1853 AMR 21115 1 (TDS) SM 2540C-2011 1 11/02/2021 1916 MOM 21024 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 140 20 20 mg CaCO3/L 1 Chloride 9056A 4.1 1.0 0.25 mg/L 1 Sulfate 9056A 31 1.0 0.25 mg/L 1 TDS SM 254OC-2011 210 25 25 mg/L 1 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0333 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 39 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-013 Description: MW-14D Matrix: Aqueous Date Sampled:10/26/2021 1205 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0333 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 90 70-130 1,2-Dichloroethane-d4 112 70-130 Toluene-d8 101 70-130 CVAA Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 11/09/2021 1609 CMS2 11/08/2021 1655 21630 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 40 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-013 Description: MW-14D Matrix: Aqueous Date Sampled:10/26/2021 1205 Date Received:10/28/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1306 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 8.0 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 240 B 50 13 ug/L 1 Lead 7439-92-1 6020B 0.39 J 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 31 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 8.8 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 41 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-014 Description: MW-14 Matrix: Aqueous Date Sampled:10/26/2021 1250 )ate Received:10/28/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 11/07/2021 0456 AAB 21752 1 (Chloride) 9056A 1 11/02/2021 1949 AMR 21118 1 (Sulfate) 9056A 1 11/02/2021 1949 AMR 21115 1 (TDS) SM 2540C-2011 1 11/02/2021 1916 MOM 21024 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 65 20 20 mg CaCO3/L 1 Chloride 9056A 2.5 1.0 0.25 mg/L 1 Sulfate 9056A 21 1.0 0.25 mg/L 1 TDS SM 254OC-2011 140 25 25 mg/L 1 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0357 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 42 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-014 Description: MW-14 Matrix: Aqueous Date Sampled:10/26/2021 1250 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0357 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 115 70-130 Toluene-d8 105 70-130 CVAA Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 11/09/2021 1612 CMS2 11/08/2021 1655 21630 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 43 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-014 Description: MW-14 Matrix: Aqueous Date Sampled:10/26/2021 1250 Date Received:10/28/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1308 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 50 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 150 B 50 13 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 4.0 J 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B 2.8 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 44 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-015 Description: MW-12D Matrix: Aqueous Date Sampled:10/26/2021 1340 Date Received:10/28/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 11/07/2021 0502 AAB 21752 1 (Chloride) 9056A 1 11/02/2021 2008 AMR 21118 1 (Sulfate) 9056A 1 11/02/2021 2008 AMR 21115 1 (TDS) SM 2540C-2011 1 11/02/2021 1916 MOM 21024 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 170 20 20 mg CaCO3/L 1 Chloride 9056A 12 1.0 0.25 mg/L 1 Sulfate 9056A 66 1.0 0.25 mg/L 1 TDS SM 254OC-2011 290 25 25 mg/L 1 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/08/2021 1312 CAW 21673 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 1.9 J 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 85 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/20210421 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 45 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-015 Description: MW-12D Matrix: Aqueous Date Sampled:10/26/2021 1340 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/20210421 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 114 70-130 Toluene-d8 104 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 46 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-015 Description: MW-12D Matrix: Aqueous Date Sampled:10/26/2021 1340 Date Received:10/28/2021 CVAA Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 11/09/2021 1614 CMS2 11/08/2021 1655 21630 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A ND 0.00020 0.000091 mg/L 1 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1310 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 63 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 2.1 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 290 B 50 13 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 470 5.0 1.3 ug/L 1 Nickel 7440-02-0 6020B 3.6 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 47 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-016 Description: MW-12 Matrix: Aqueous Date Sampled:10/26/2021 1420 Date Received:10/28/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 11/07/2021 0510 AAB 21752 1 (Chloride) 9056A 1 11/02/2021 2027 AMR 21118 2 (Sulfate) 9056A 5 11/03/2021 1855 AMR 21362 1 (TDS) SM 2540C-2011 1 11/02/2021 1916 MOM 21024 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 240 20 20 mg CaCO3/L 1 Chloride 9056A 38 1.0 0.25 mg/L 1 Sulfate 9056A 290 5.0 1.3 mg/L 2 TDS SM 2540C-2011 680 25 25 mg/L 1 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/08/2021 1336 CAW 21673 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 2.8 J 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 85 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/20210445 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 8.1 JL 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 48 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-016 Description: MW-12 Matrix: Aqueous Date Sampled:10/26/2021 1420 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0445 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D 3.4 J 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 91 70-130 1,2-Dichloroethane-d4 114 70-130 Toluene-d8 104 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 49 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-016 Description: MW-12 Matrix: Aqueous Date Sampled:10/26/2021 1420 Date Received:10/28/2021 CVAA Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 11/09/2021 1622 CMS2 11/08/2021 1655 21630 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00023 0.00020 0.000091 mg/L 1 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1312 BNW 11/04/2021 0914 21233 2 3005A 6020B 5 11/10/2021 1200 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 110 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.40 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.5 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 29 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 19 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 130 B 50 13 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Manganese 7439-96-5 6020B 2500 25 6.3 ug/L 2 Nickel 7440-02-0 6020B 34 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 6.4 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 50 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-017 Description: MW-13D Matrix: Aqueous Date Sampled:10/26/2021 1520 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0509 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 51 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-017 Description: MW-13D Matrix: Aqueous Date Sampled:10/26/2021 1520 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0509 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 113 70-130 Toluene-d8 104 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1314 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 230 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 21 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 9.6 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 52 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-018 Description: MW-13 Matrix: Aqueous Date Sampled:10/26/2021 1550 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0533 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 53 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-018 Description: MW-13 Matrix: Aqueous Date Sampled:10/26/2021 1550 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0533 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 91 70-130 1,2-Dichloroethane-d4 112 70-130 Toluene-d8 104 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1316 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 200 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 26 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.26 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 6.3 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 9.8 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 54 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-019 Description: MW-8 Matrix: Aqueous Date Sampled:10/26/2021 1645 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0557 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 55 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-019 Description: MW-8 Matrix: Aqueous Date Sampled:10/26/2021 1645 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/2021 0557 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 115 70-130 Toluene-d8 103 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1323 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 1.6 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 140 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.7 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.7 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.26 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 3.1 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 16 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 56 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-020 Description: MW-8D. Matrix: Aqueous Date Sampled:10/26/2021 1700 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/20210621 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 57 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-020 Description: MW-8D. Matrix: Aqueous Date Sampled:10/26/2021 1700 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/20210621 JWO 21730 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 114 70-130 Toluene-d8 103 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1325 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 170 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.4 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 4.3 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 4.7 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 58 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-021 Description: MW-10 Matrix: Aqueous Date Sampled:10/28/2021 1010 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/08/2021 1401 CAW 21673 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 88 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211309 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND L 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 59 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-021 Description: MW-10 Matrix: Aqueous Date Sampled:10/28/2021 1010 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211309 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 0.51 J 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 86 70-130 1,2-Dichloroethane-d4 108 70-130 Toluene-d8 99 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1327 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 140 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.9 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 3.3 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 11 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 60 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-021 Description: MW-10 Matrix: Aqueous Date Sampled:10/28/2021 1010 Date Received:10/30/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1327 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 2.6 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 4.6 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 61 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-022 Description: MW-10D Matrix: Aqueous Date Sampled:10/28/2021 1045 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/08/2021 1425 CAW 21673 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 86 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211335 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND L 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.84 J 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 0.47 J 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 62 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-022 Description: MW-10D Matrix: Aqueous Date Sampled:10/28/2021 1045 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211335 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 81 70-130 1,2-Dichloroethane-d4 104 70-130 Toluene-d8 112 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1329 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 30 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.8 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 12 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 63 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-022 Description: MW-10D Matrix: Aqueous Date Sampled:10/28/2021 1045 Date Received:10/30/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1329 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 64 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-023 Description: MW-3R Matrix: Aqueous Date Sampled:10/28/2021 1240 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211400 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND L 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 65 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-023 Description: MW-3R Matrix: Aqueous Date Sampled:10/28/2021 1240 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211400 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 82 70-130 1,2-Dichloroethane-d4 106 70-130 Toluene-d8 97 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1331 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 64 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.0 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 3.1 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 4.3 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.9 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 66 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-024 Description: MW-7 Matrix: Aqueous Date Sampled:10/28/2021 1350 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211425 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND L 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 67 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-024 Description: MW-7 Matrix: Aqueous Date Sampled:10/28/2021 1350 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211425 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 83 70-130 1,2-Dichloroethane-d4 107 70-130 Toluene-d8 98 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1333 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 180 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.7 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 1.8 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 15 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 3.7 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 68 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-025 Description: MW-5D Matrix: Aqueous Date Sampled:10/28/2021 1200 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211451 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND L 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 69 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-025 Description: MW-5D Matrix: Aqueous Date Sampled:10/28/2021 1200 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211451 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 70 70-130 1,2-Dichloroethane-d4 104 70-130 Toluene-d8 96 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/05/2021 1335 BNW 11/04/2021 0914 21233 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 74 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.3 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.5 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 2.9 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 70 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-026 Description: MW-5 Matrix: Aqueous Date Sampled:10/28/2021 1235 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211516 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND L 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 71 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-026 Description: MW-5 Matrix: Aqueous Date Sampled:10/28/2021 1235 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211516 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 83 70-130 1,2-Dichloroethane-d4 105 70-130 Toluene-d8 96 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1703 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 130 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.7 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.33 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 8.7 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 2.8 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.1 BJ 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 72 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-027 Description: MW-6 Matrix: Aqueous Date Sampled:10/28/2021 1520 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211541 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND L 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 73 of 149 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID: WJ30017-027 Description: MW-6 Matrix: Aqueous Date Sampled:10/28/2021 1520 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211541 BWS 22207 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 83 70-130 1,2-Dichloroethane-d4 105 70-130 Toluene-d8 98 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1705 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 50 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 3.0 BJ 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 74 of 149 QC Summary Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 75 of 149 Inorganic non-metals - MB Sample ID: WQ21024-001 Matrix: Aqueous Batch: 21024 Analytical Method: SM 2540C-2011 Parameter Result Q Dil LOQ DL Units Analysis Date TDS ND 1 25 25 mg/L 11/02/2021 1719 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 76 of 149 Inorganic non-metals - LCS Sample ID: WQ21024-002 Matrix: Aqueous Batch: 21024 Analytical Method: SM 2540C-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date TDS 1500 1500 1 101 90-110 11/02/2021 1719 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 77 of 149 Inorganic non-metals - Duplicate Sample ID: WJ30017-015DU Matrix: Aqueous Batch: 21024 Analytical Method: SM 2540C-2011 Sample Amount Result %RPD Parameter (mg/L) (mg/L) Q Dil % RPD Limit Analysis Date TDS 290 300 1 3.7 20 11/02/2021 1719 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 78 of 149 Inorganic non-metals - Duplicate Sample ID: WJ30017-016DU Matrix: Aqueous Batch: 21024 Analytical Method: SM 2540C-2011 Sample Amount Result %RPD Parameter (mg/L) (mg/L) Q Dil % RPD Limit Analysis Date TDS 680 700 1 2.8 20 11/02/2021 1719 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 79 of 149 Inorganic non-metals - MB Sample ID: WQ21115-001 Matrix: Aqueous Batch: 21115 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate ND 1 1.0 0.25 mg/L 11/02/2021 1544 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 80 of 149 Inorganic non-metals - LCS Sample ID: WQ21115-002 Matrix: Aqueous Batch: 21115 Analytical Method: 9056A Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfate 20 20 1 102 80-120 11/02/2021 1621 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 81 of 149 Inorganic non-metals - MS Sample ID: WJ30017-01 1 MS Matrix: Aqueous Batch: 21115 Analytical Method: 9056A Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfate 41 10 51 1 95 80-120 11/02/2021 1756 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 82 of 149 Inorganic non-metals - MSD Sample ID: WJ30017-011MID Matrix: Aqueous Batch: 21115 Analytical Method: 9056A Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Sulfate 41 10 51 1 98 0.48 80-120 20 11/02/2021 1815 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 83 of 149 Inorganic non-metals - MB Sample ID: WQ21118-001 Matrix: Aqueous Batch: 21118 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Chloride ND 1 1.0 0.25 mg/L 11/02/2021 1544 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 84 of 149 Inorganic non-metals - LCS Sample ID: WQ21118-002 Matrix: Aqueous Batch: 21118 Analytical Method: 9056A Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Chloride 20 21 1 104 80-120 11/02/2021 1621 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 85 of 149 Inorganic non-metals - MS Sample ID: WJ30017-01 1 MS Matrix: Aqueous Batch: 21118 Analytical Method: 9056A Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Chloride 2.5 10 13 1 103 80-120 11/02/2021 1756 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 86 of 149 Inorganic non-metals - MSD Sample ID: WJ30017-011MID Matrix: Aqueous Batch: 21118 Analytical Method: 9056A Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Chloride 2.5 10 13 1 102 0.29 80-120 20 11/02/2021 1815 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 87 of 149 Inorganic non-metals - MB Sample ID: WQ21362-001 Matrix: Aqueous Batch: 21362 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate ND 1 1.0 0.25 mg/L 11/03/2021 1605 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 88 of 149 Inorganic non-metals - LCS Sample ID: WQ21362-002 Matrix: Aqueous Batch: 21362 Analytical Method: 9056A Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfate 20 20 1 101 80-120 11 /03/2021 1643 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 89 of 149 Inorganic non-metals - LCS Sample ID: WQ21752-002 Matrix: Aqueous Batch: 21752 Analytical Method: SM 2320B-2011 Spike Amount Result %Rec Parameter (mg CaCO3/L) (mg CaCO3/L) Q Dil % Rec Limit Analysis Date Alkalinity @ pH 4.5 su 100 99 1 99 90-110 11/07/2021 0313 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 90 of 149 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: WQ21040-001 Matrix: Aqueous Batch:21040 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane ND 1 3.0 1.0 ug/L 11/02/2021 1938 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 83 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 91 of 149 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: WQ21040-002 Matrix: Aqueous Batch:21040 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 49 1 98 70-130 11/02/2021 1831 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 101 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 92 of 149 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: WQ21673-001 Matrix: Aqueous Batch:21673 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane ND 1 3.0 1.0 ug/L 11/08/2021 1012 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 85 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 93 of 149 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: WQ21673-002 Matrix: Aqueous Batch:21673 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 53 1 106 70-130 11/08/2021 0907 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 92 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 94 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21730-001 Matrix: Aqueous Batch: 21730 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 11/09/2021 0001 Acrylonitrile ND 1 20 0.80 ug/L 11/09/2021 0001 Benzene ND 1 1.0 0.40 ug/L 11/09/2021 0001 Bromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 Bromodichloromethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 Bromoform ND 1 1.0 0.40 ug/L 11/09/2021 0001 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 11/09/2021 0001 2-Butanone (MEK) ND 1 10 2.0 ug/L 11/09/2021 0001 Carbon disulfide ND 1 1.0 0.40 ug/L 11/09/2021 0001 Carbon tetrachloride ND 1 1.0 0.40 ug/L 11/09/2021 0001 Chlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 0001 Chloroethane ND 1 2.0 0.40 ug/L 11/09/2021 0001 Chloroform ND 1 1.0 0.40 ug/L 11/09/2021 0001 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 11/09/2021 0001 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 11/09/2021 0001 Dibromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 11/09/2021 0001 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 11/09/2021 0001 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 11/09/2021 0001 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 0001 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 0001 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 0001 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 0001 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 0001 Ethylbenzene ND 1 1.0 0.40 ug/L 11/09/2021 0001 2-Hexanone ND 1 10 2.0 ug/L 11/09/2021 0001 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 11/09/2021 0001 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 11/09/2021 0001 Methylene chloride ND 1 1.0 0.40 ug/L 11/09/2021 0001 Styrene ND 1 1.0 0.41 ug/L 11/09/2021 0001 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 Tetrachloroethene ND 1 1.0 0.40 ug/L 11/09/2021 0001 Toluene ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 Trichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 0001 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 0001 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 95 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21730-001 Matrix: Aqueous Batch:21730 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 11/09/2021 0001 Vinyl chloride ND 1 1.0 0.40 ug/L 11/09/2021 0001 Xylenes (total) ND 1 1.0 0.40 ug/L 11/09/2021 0001 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 93 70-130 1,2-Dichloroethane-d4 113 70-130 Toluene-d8 103 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 96 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21730-002 Matrix: Aqueous Batch: 21730 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 150 N 1 148 60-140 11/08/2021 1938 Acrylonitrile 100 120 1 121 70-130 11/08/2021 1938 Benzene 50 56 1 111 70-130 11/08/2021 1938 Bromochloromethane 50 53 1 107 70-130 11/08/2021 1938 Bromodichloromethane 50 54 1 109 70-130 11/08/2021 1938 Bromoform 50 52 1 105 70-130 11/08/2021 1938 Bromomethane (Methyl bromide) 50 49 1 98 70-130 11/08/2021 1938 2-Butanone (MEK) 100 120 1 118 70-130 11/08/2021 1938 Carbon disulfide 50 63 1 126 70-130 11/08/2021 1938 Carbon tetrachloride 50 56 1 112 70-130 11/08/2021 1938 Chlorobenzene 50 52 1 104 70-130 11/08/2021 1938 Chloroethane 50 57 1 115 70-130 11/08/2021 1938 Chloroform 50 53 1 107 70-130 11/08/2021 1938 Chloromethane (Methyl chloride) 50 57 1 113 60-140 11/08/2021 1938 1,2-Dibromo-3-chloropropane (DBCP) 50 57 1 114 70-130 11/08/2021 1938 Dibromochloromethane 50 54 1 107 70-130 11/08/2021 1938 1,2-Dibromoethane (EDB) 50 52 1 103 70-130 11/08/2021 1938 Dibromomethane (Methylene bromide) 50 55 1 109 70-130 11/08/2021 1938 trans- 1,4-Dichloro-2-butene 50 56 1 112 70-130 11/08/2021 1938 1,2-Dichlorobenzene 50 52 1 104 70-130 11/08/2021 1938 1,4-Dichlorobenzene 50 50 1 99 70-130 11/08/2021 1938 1,1-Dichloroethane 50 55 1 110 70-130 11/08/2021 1938 1,2-Dichloroethane 50 54 1 109 70-130 11/08/2021 1938 1,1-Dichloroethene 50 61 1 122 70-130 11/08/2021 1938 cis- 1,2-Dichloroethene 50 55 1 111 70-130 11/08/2021 1938 trans- 1,2-Dichloroethene 50 57 1 115 70-130 11/08/2021 1938 1,2-Dichloropropane 50 55 1 109 70-130 11/08/2021 1938 cis- 1,3-Dichloropropene 50 54 1 109 70-130 11/08/2021 1938 trans- 1,3-Dichloropropene 50 55 1 110 70-130 11/08/2021 1938 Ethylbenzene 50 54 1 109 70-130 11/08/2021 1938 2-Hexanone 100 120 1 121 70-130 11/08/2021 1938 Methyl iodide (lodomethane) 50 56 1 112 70-130 11/08/2021 1938 4-Methyl-2-pentanone 100 120 1 119 70-130 11/08/2021 1938 Methylene chloride 50 56 1 112 70-130 11/08/2021 1938 Styrene 50 57 1 113 70-130 11/08/2021 1938 1,1,1,2-Tetrachloroethane 50 54 1 108 70-130 11/08/2021 1938 1,1,2,2-Tetrachloroethane 50 54 1 109 70-130 11/08/2021 1938 Tetrachloroethene 50 52 1 105 70-130 11/08/2021 1938 Toluene 50 55 1 110 70-130 11/08/2021 1938 1,1,1-Trichloroethane 50 55 1 110 70-130 11/08/2021 1938 1,1,2-Trichloroethane 50 52 1 105 70-130 11/08/2021 1938 Trichloroethene 50 50 1 100 70-130 11/08/2021 1938 Trichlorofluoromethane 50 58 1 115 70-130 11/08/2021 1938 1,2,3-Trichloropropane 50 53 1 106 70-130 11/08/2021 1938 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 97 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21730-002 Matrix: Aqueous Batch:21730 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 52 1 103 60-140 11/08/2021 1938 Vinyl chloride 50 55 1 110 70-130 11/08/2021 1938 Xylenes (total) 100 110 1 112 70-130 11/08/2021 1938 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 103 70-130 1,2-Dichloroethane-d4 108 70-130 Toluene-d8 105 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 98 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21730-001 Matrix: Aqueous Batch: 21730 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 11/09/2021 0001 Acrylonitrile ND 1 20 0.80 ug/L 11/09/2021 0001 Benzene ND 1 1.0 0.40 ug/L 11/09/2021 0001 Bromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 Bromodichloromethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 Bromoform ND 1 1.0 0.40 ug/L 11/09/2021 0001 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 11/09/2021 0001 2-Butanone (MEK) ND 1 10 2.0 ug/L 11/09/2021 0001 Carbon disulfide ND 1 1.0 0.40 ug/L 11/09/2021 0001 Carbon tetrachloride ND 1 1.0 0.40 ug/L 11/09/2021 0001 Chlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 0001 Chloroethane ND 1 2.0 0.40 ug/L 11/09/2021 0001 Chloroform ND 1 1.0 0.40 ug/L 11/09/2021 0001 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 11/09/2021 0001 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 11/09/2021 0001 Dibromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 11/09/2021 0001 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 11/09/2021 0001 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 11/09/2021 0001 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 0001 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 0001 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 0001 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 0001 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 0001 Ethylbenzene ND 1 1.0 0.40 ug/L 11/09/2021 0001 2-Hexanone ND 1 10 2.0 ug/L 11/09/2021 0001 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 11/09/2021 0001 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 11/09/2021 0001 Methylene chloride ND 1 1.0 0.40 ug/L 11/09/2021 0001 Styrene ND 1 1.0 0.41 ug/L 11/09/2021 0001 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 Tetrachloroethene ND 1 1.0 0.40 ug/L 11/09/2021 0001 Tetrahydrofuran ND 1 5.0 1.0 ug/L 11/09/2021 0001 Toluene ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 Trichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 0001 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 11/09/2021 0001 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 99 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21730-001 Matrix: Aqueous Batch:21730 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 0001 Vinyl acetate ND 1 5.0 1.2 ug/L 11/09/2021 0001 Vinyl chloride ND 1 1.0 0.40 ug/L 11/09/2021 0001 Xylenes (total) ND 1 1.0 0.40 ug/L 11/09/2021 0001 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 93 70-130 1,2-Dichloroethane-d4 113 70-130 Toluene-d8 103 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 100 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21730-002 Matrix: Aqueous Batch: 21730 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 150 N 1 148 60-140 11/08/2021 1938 Acrylonitrile 100 120 1 121 70-130 11/08/2021 1938 Benzene 50 56 1 111 70-130 11/08/2021 1938 Bromochloromethane 50 53 1 107 70-130 11/08/2021 1938 Bromodichloromethane 50 54 1 109 70-130 11/08/2021 1938 Bromoform 50 52 1 105 70-130 11/08/2021 1938 Bromomethane (Methyl bromide) 50 49 1 98 70-130 11/08/2021 1938 2-Butanone (MEK) 100 120 1 118 70-130 11/08/2021 1938 Carbon disulfide 50 63 1 126 70-130 11/08/2021 1938 Carbon tetrachloride 50 56 1 112 70-130 11/08/2021 1938 Chlorobenzene 50 52 1 104 70-130 11/08/2021 1938 Chloroethane 50 57 1 115 70-130 11/08/2021 1938 Chloroform 50 53 1 107 70-130 11/08/2021 1938 Chloromethane (Methyl chloride) 50 57 1 113 60-140 11/08/2021 1938 1,2-Dibromo-3-chloropropane (DBCP) 50 57 1 114 70-130 11/08/2021 1938 Dibromochloromethane 50 54 1 107 70-130 11/08/2021 1938 1,2-Dibromoethane (EDB) 50 52 1 103 70-130 11/08/2021 1938 Dibromomethane (Methylene bromide) 50 55 1 109 70-130 11/08/2021 1938 trans- 1,4-Dichloro-2-butene 50 56 1 112 70-130 11/08/2021 1938 1,2-Dichlorobenzene 50 52 1 104 70-130 11/08/2021 1938 1,4-Dichlorobenzene 50 50 1 99 70-130 11/08/2021 1938 1,1-Dichloroethane 50 55 1 110 70-130 11/08/2021 1938 1,2-Dichloroethane 50 54 1 109 70-130 11/08/2021 1938 1,1-Dichloroethene 50 61 1 122 70-130 11/08/2021 1938 cis- 1,2-Dichloroethene 50 55 1 111 70-130 11/08/2021 1938 trans- 1,2-Dichloroethene 50 57 1 115 70-130 11/08/2021 1938 1,2-Dichloropropane 50 55 1 109 70-130 11/08/2021 1938 cis- 1,3-Dichloropropene 50 54 1 109 70-130 11/08/2021 1938 trans- 1,3-Dichloropropene 50 55 1 110 70-130 11/08/2021 1938 Ethylbenzene 50 54 1 109 70-130 11/08/2021 1938 2-Hexanone 100 120 1 121 70-130 11/08/2021 1938 Methyl iodide (lodomethane) 50 56 1 112 70-130 11/08/2021 1938 4-Methyl-2-pentanone 100 120 1 119 70-130 11/08/2021 1938 Methylene chloride 50 56 1 112 70-130 11/08/2021 1938 Styrene 50 57 1 113 70-130 11/08/2021 1938 1,1,1,2-Tetrachloroethane 50 54 1 108 70-130 11/08/2021 1938 1,1,2,2-Tetrachloroethane 50 54 1 109 70-130 11/08/2021 1938 Tetrachloroethene 50 52 1 105 70-130 11/08/2021 1938 Tetrahydrofuran 50 61 1 121 70-130 11/08/2021 1938 Toluene 50 55 1 110 70-130 11/08/2021 1938 1,1,1-Trichloroethane 50 55 1 110 70-130 11/08/2021 1938 1,1,2-Trichloroethane 50 52 1 105 70-130 11/08/2021 1938 Trichloroethene 50 50 1 100 70-130 11/08/2021 1938 Trichlorofluoromethane 50 58 1 115 70-130 11/08/2021 1938 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 101 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21730-002 Matrix: Aqueous Batch:21730 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,2,3-Trichloropropane 50 53 1 106 70-130 11/08/2021 1938 Vinyl acetate 50 52 1 103 60-140 11/08/2021 1938 Vinyl chloride 50 55 1 110 70-130 11/08/2021 1938 Xylenes (total) 100 110 1 112 70-130 11/08/2021 1938 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 103 70-130 1,2-Dichloroethane-d4 108 70-130 Toluene-d8 105 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 102 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21793-001 Matrix: Aqueous Batch: 21793 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 11/09/2021 1038 Acrylonitrile ND 1 20 0.80 ug/L 11/09/2021 1038 Benzene ND 1 1.0 0.40 ug/L 11/09/2021 1038 Bromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 Bromodichloromethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 Bromoform ND 1 1.0 0.40 ug/L 11/09/2021 1038 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 11/09/2021 1038 2-Butanone (MEK) ND 1 10 2.0 ug/L 11/09/2021 1038 Carbon disulfide ND 1 1.0 0.40 ug/L 11/09/2021 1038 Carbon tetrachloride ND 1 1.0 0.40 ug/L 11/09/2021 1038 Chlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 1038 Chloroethane ND 1 2.0 0.40 ug/L 11/09/2021 1038 Chloroform ND 1 1.0 0.40 ug/L 11/09/2021 1038 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 11/09/2021 1038 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 11/09/2021 1038 Dibromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 11/09/2021 1038 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 11/09/2021 1038 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 11/09/2021 1038 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 1038 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 1038 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 1038 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 1038 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 1038 Ethylbenzene ND 1 1.0 0.40 ug/L 11/09/2021 1038 2-Hexanone ND 1 10 2.0 ug/L 11/09/2021 1038 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 11/09/2021 1038 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 11/09/2021 1038 Methylene chloride ND 1 1.0 0.40 ug/L 11/09/2021 1038 Styrene ND 1 1.0 0.41 ug/L 11/09/2021 1038 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 Tetrachloroethene ND 1 1.0 0.40 ug/L 11/09/2021 1038 Tetrahydrofuran ND 1 5.0 1.0 ug/L 11/09/2021 1038 Toluene ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 Trichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 1038 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 103 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21793-001 Matrix: Aqueous Batch: 21793 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 1038 Vinyl chloride ND 1 1.0 0.40 ug/L 11/09/2021 1038 Xylenes (total) ND 1 1.0 0.40 ug/L 11/09/2021 1038 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 112 70-130 Toluene-d8 102 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 104 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21793-002 Matrix: Aqueous Batch: 21793 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 140 N 1 141 60-140 11/09/2021 0935 Acrylonitrile 100 120 1 119 70-130 11/09/2021 0935 Benzene 50 55 1 110 70-130 11/09/2021 0935 Bromochloromethane 50 53 1 107 70-130 11/09/2021 0935 Bromodichloromethane 50 55 1 109 70-130 11/09/2021 0935 Bromoform 50 53 1 107 70-130 11/09/2021 0935 Bromomethane (Methyl bromide) 50 49 1 98 70-130 11/09/2021 0935 2-Butanone (MEK) 100 120 1 116 70-130 11/09/2021 0935 Carbon disulfide 50 58 1 115 70-130 11/09/2021 0935 Carbon tetrachloride 50 53 1 106 70-130 11/09/2021 0935 Chlorobenzene 50 52 1 104 70-130 11/09/2021 0935 Chloroethane 50 57 1 114 70-130 11/09/2021 0935 Chloroform 50 53 1 106 70-130 11/09/2021 0935 Chloromethane (Methyl chloride) 50 57 1 113 60-140 11/09/2021 0935 1,2-Dibromo-3-chloropropane (DBCP) 50 56 1 111 70-130 11/09/2021 0935 Dibromochloromethane 50 53 1 107 70-130 11/09/2021 0935 1,2-Dibromoethane (EDB) 50 52 1 104 70-130 11/09/2021 0935 Dibromomethane (Methylene bromide) 50 56 1 112 70-130 11/09/2021 0935 trans- 1,4-Dichloro-2-butene 50 56 1 112 70-130 11/09/2021 0935 1,2-Dichlorobenzene 50 52 1 104 70-130 11/09/2021 0935 1,4-Dichlorobenzene 50 50 1 99 70-130 11/09/2021 0935 1,1-Dichloroethane 50 54 1 109 70-130 11/09/2021 0935 1,2-Dichloroethane 50 55 1 110 70-130 11/09/2021 0935 1,1-Dichloroethene 50 56 1 112 70-130 11/09/2021 0935 cis- 1,2-Dichloroethene 50 53 1 107 70-130 11/09/2021 0935 trans- 1,2-Dichloroethene 50 56 1 111 70-130 11/09/2021 0935 1,2-Dichloropropane 50 55 1 109 70-130 11/09/2021 0935 cis- 1,3-Dichloropropene 50 54 1 107 70-130 11/09/2021 0935 trans- 1,3-Dichloropropene 50 54 1 109 70-130 11/09/2021 0935 Ethylbenzene 50 54 1 108 70-130 11/09/2021 0935 2-Hexanone 100 120 1 125 70-130 11/09/2021 0935 Methyl iodide (lodomethane) 50 53 1 106 70-130 11/09/2021 0935 4-Methyl-2-pentanone 100 120 1 119 70-130 11/09/2021 0935 Methylene chloride 50 54 1 108 70-130 11/09/2021 0935 Styrene 50 58 1 115 70-130 11/09/2021 0935 1,1,1,2-Tetrachloroethane 50 55 1 109 70-130 11/09/2021 0935 1,1,2,2-Tetrachloroethane 50 55 1 109 70-130 11/09/2021 0935 Tetrachloroethene 50 51 1 102 70-130 11/09/2021 0935 Tetrahydrofuran 50 61 1 122 70-130 11/09/2021 0935 Toluene 50 55 1 110 70-130 11/09/2021 0935 1,1,1-Trichloroethane 50 53 1 106 70-130 11/09/2021 0935 1,1,2-Trichloroethane 50 53 1 106 70-130 11/09/2021 0935 Trichloroethene 50 49 1 98 70-130 11/09/2021 0935 Trichlorofluoromethane 50 53 1 105 70-130 11/09/2021 0935 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 105 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21793-002 Matrix: Aqueous Batch: 21793 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,2,3-Trichloropropane 50 53 1 106 70-130 11/09/2021 0935 Vinyl chloride 50 52 1 103 70-130 11/09/2021 0935 Xylenes (total) 100 110 1 111 70-130 11/09/2021 0935 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 103 70-130 1,2-Dichloroethane-d4 109 70-130 Toluene-d8 103 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 106 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21870-001 Matrix: Aqueous Batch: 21870 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 11/09/2021 2311 Acrylonitrile ND 1 20 0.80 ug/L 11/09/2021 2311 Benzene ND 1 1.0 0.40 ug/L 11/09/2021 2311 Bromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2311 Bromodichloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2311 Bromoform ND 1 1.0 0.40 ug/L 11/09/2021 2311 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 11/09/2021 2311 2-Butanone (MEK) ND 1 10 2.0 ug/L 11/09/2021 2311 Carbon disulfide ND 1 1.0 0.40 ug/L 11/09/2021 2311 Carbon tetrachloride ND 1 1.0 0.40 ug/L 11/09/2021 2311 Chlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2311 Chloroethane ND 1 2.0 0.40 ug/L 11/09/2021 2311 Chloroform ND 1 1.0 0.40 ug/L 11/09/2021 2311 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 11/09/2021 2311 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 11/09/2021 2311 Dibromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2311 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 11/09/2021 2311 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 11/09/2021 2311 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 11/09/2021 2311 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2311 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2311 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2311 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2311 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2311 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2311 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2311 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 2311 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 2311 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 2311 Ethylbenzene ND 1 1.0 0.40 ug/L 11/09/2021 2311 2-Hexanone ND 1 10 2.0 ug/L 11/09/2021 2311 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 11/09/2021 2311 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 11/09/2021 2311 Methylene chloride ND 1 1.0 0.40 ug/L 11/09/2021 2311 Styrene ND 1 1.0 0.41 ug/L 11/09/2021 2311 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2311 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2311 Tetrachloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2311 Toluene ND 1 1.0 0.40 ug/L 11/09/2021 2311 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2311 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2311 Trichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2311 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 11/09/2021 2311 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 2311 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 107 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21870-001 Matrix: Aqueous Batch:21870 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 11/09/2021 2311 Vinyl chloride ND 1 1.0 0.40 ug/L 11/09/2021 2311 Xylenes (total) ND 1 1.0 0.40 ug/L 11/09/2021 2311 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 111 70-130 Toluene-d8 102 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 108 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21870-002 Matrix: Aqueous Batch: 21870 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 130 1 132 60-140 11/09/2021 2205 Acrylonitrile 100 120 1 122 70-130 11/09/2021 2205 Benzene 50 54 1 107 70-130 11/09/2021 2205 Bromochloromethane 50 53 1 106 70-130 11/09/2021 2205 Bromodichloromethane 50 54 1 107 70-130 11/09/2021 2205 Bromoform 50 51 1 101 70-130 11/09/2021 2205 Bromomethane (Methyl bromide) 50 47 1 93 70-130 11/09/2021 2205 2-Butanone (MEK) 100 110 1 114 70-130 11/09/2021 2205 Carbon disulfide 50 60 1 120 70-130 11/09/2021 2205 Carbon tetrachloride 50 53 1 105 70-130 11/09/2021 2205 Chlorobenzene 50 50 1 101 70-130 11/09/2021 2205 Chloroethane 50 56 1 113 70-130 11/09/2021 2205 Chloroform 50 53 1 106 70-130 11/09/2021 2205 Chloromethane (Methyl chloride) 50 55 1 111 60-140 11/09/2021 2205 1,2-Dibromo-3-chloropropane (DBCP) 50 55 1 110 70-130 11/09/2021 2205 Dibromochloromethane 50 52 1 104 70-130 11/09/2021 2205 1,2-Dibromoethane (EDB) 50 52 1 103 70-130 11/09/2021 2205 Dibromomethane (Methylene bromide) 50 54 1 109 70-130 11/09/2021 2205 trans- 1,4-Dichloro-2-butene 50 54 1 109 70-130 11/09/2021 2205 1,2-Dichlorobenzene 50 50 1 101 70-130 11/09/2021 2205 1,4-Dichlorobenzene 50 48 1 97 70-130 11/09/2021 2205 1,1-Dichloroethane 50 53 1 107 70-130 11/09/2021 2205 1,2-Dichloroethane 50 54 1 107 70-130 11/09/2021 2205 1,1-Dichloroethene 50 59 1 118 70-130 11/09/2021 2205 cis- 1,2-Dichloroethene 50 54 1 108 70-130 11/09/2021 2205 trans- 1,2-Dichloroethene 50 56 1 111 70-130 11/09/2021 2205 1,2-Dichloropropane 50 53 1 107 70-130 11/09/2021 2205 cis- 1,3-Dichloropropene 50 53 1 106 70-130 11/09/2021 2205 trans- 1,3-Dichloropropene 50 54 1 107 70-130 11/09/2021 2205 Ethylbenzene 50 52 1 104 70-130 11/09/2021 2205 2-Hexanone 100 120 1 116 70-130 11/09/2021 2205 Methyl iodide (lodomethane) 50 54 1 108 70-130 11/09/2021 2205 4-Methyl-2-pentanone 100 120 1 116 70-130 11/09/2021 2205 Methylene chloride 50 56 1 112 70-130 11/09/2021 2205 Styrene 50 55 1 111 70-130 11/09/2021 2205 1,1,1,2-Tetrachloroethane 50 53 1 105 70-130 11/09/2021 2205 1,1,2,2-Tetrachloroethane 50 52 1 104 70-130 11/09/2021 2205 Tetrachloroethene 50 50 1 99 70-130 11/09/2021 2205 Toluene 50 53 1 107 70-130 11/09/2021 2205 1,1,1-Trichloroethane 50 53 1 107 70-130 11/09/2021 2205 1,1,2-Trichloroethane 50 52 1 105 70-130 11/09/2021 2205 Trichloroethene 50 48 1 96 70-130 11/09/2021 2205 Trichlorofluoromethane 50 50 1 100 70-130 11/09/2021 2205 1,2,3-Trichloropropane 50 52 1 104 70-130 11/09/2021 2205 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 109 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21870-002 Matrix: Aqueous Batch:21870 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 51 1 102 60-140 11/09/2021 2205 Vinyl chloride 50 51 1 102 70-130 11/09/2021 2205 Xylenes (total) 100 110 1 107 70-130 11/09/2021 2205 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 98 70-130 1,2-Dichloroethane-d4 106 70-130 Toluene-d8 100 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 110 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21878-001 Matrix: Aqueous Batch: 21878 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 11/09/2021 2245 Acrylonitrile ND 1 20 0.80 ug/L 11/09/2021 2245 Benzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromodichloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromoform ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 11/09/2021 2245 Carbon disulfide ND 1 1.0 0.40 ug/L 11/09/2021 2245 Carbon tetrachloride ND 1 1.0 0.40 ug/L 11/09/2021 2245 Chlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Chloroethane ND 1 2.0 0.40 ug/L 11/09/2021 2245 Chloroform ND 1 1.0 0.40 ug/L 11/09/2021 2245 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 11/09/2021 2245 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 11/09/2021 2245 Dibromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 11/09/2021 2245 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 11/09/2021 2245 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 11/09/2021 2245 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 2245 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 2245 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Ethylbenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 2-Hexanone ND 1 10 2.0 ug/L 11/09/2021 2245 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 11/09/2021 2245 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 11/09/2021 2245 Methylene chloride ND 1 1.0 0.40 ug/L 11/09/2021 2245 Styrene ND 1 1.0 0.41 ug/L 11/09/2021 2245 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Tetrachloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Toluene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Trichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Vinyl chloride ND 1 1.0 0.40 ug/L 11/09/2021 2245 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 111 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21878-001 Matrix: Aqueous Batch:21878 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Xylenes (total) ND 1 1.0 0.40 ug/L 11/09/2021 2245 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 90 70-130 1,2-Dichloroethane-d4 97 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 112 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21878-002 Matrix: Aqueous Batch: 21878 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 78 1 78 60-140 11/09/2021 2141 Acrylonitrile 100 86 1 86 70-130 11/09/2021 2141 Benzene 50 46 1 93 70-130 11/09/2021 2141 Bromochloromethane 50 45 1 90 70-130 11/09/2021 2141 Bromodichloromethane 50 49 1 97 70-130 11/09/2021 2141 Bromoform 50 54 1 109 70-130 11/09/2021 2141 Bromomethane (Methyl bromide) 50 43 1 87 70-130 11/09/2021 2141 Carbon disulfide 50 50 1 99 70-130 11/09/2021 2141 Carbon tetrachloride 50 47 1 95 70-130 11/09/2021 2141 Chlorobenzene 50 48 1 97 70-130 11/09/2021 2141 Chloroethane 50 42 1 84 70-130 11/09/2021 2141 Chloroform 50 43 1 86 70-130 11/09/2021 2141 Chloromethane (Methyl chloride) 50 38 1 76 60-140 11/09/2021 2141 1,2-Dibromo-3-chloropropane (DBCP) 50 47 1 94 70-130 11/09/2021 2141 Dibromochloromethane 50 51 1 102 70-130 11/09/2021 2141 1,2-Dibromoethane (EDB) 50 50 1 100 70-130 11/09/2021 2141 Dibromomethane (Methylene bromide) 50 46 1 93 70-130 11/09/2021 2141 trans- 1,4-Dichloro-2-butene 50 46 1 91 70-130 11/09/2021 2141 1,2-Dichlorobenzene 50 48 1 96 70-130 11/09/2021 2141 1,4-Dichlorobenzene 50 45 1 90 70-130 11/09/2021 2141 1,1-Dichloroethane 50 43 1 86 70-130 11/09/2021 2141 1,2-Dichloroethane 50 45 1 90 70-130 11/09/2021 2141 1,1-Dichloroethene 50 47 1 93 70-130 11/09/2021 2141 cis- 1,2-Dichloroethene 50 43 1 87 70-130 11/09/2021 2141 trans- 1,2-Dichloroethene 50 43 1 87 70-130 11/09/2021 2141 1,2-Dichloropropane 50 49 1 98 70-130 11/09/2021 2141 cis- 1,3-Dichloropropene 50 54 1 108 70-130 11/09/2021 2141 trans- 1,3-Dichloropropene 50 48 1 96 70-130 11/09/2021 2141 Ethylbenzene 50 49 1 98 70-130 11/09/2021 2141 2-Hexanone 100 100 1 103 70-130 11/09/2021 2141 Methyl iodide (lodomethane) 50 50 1 100 70-130 11/09/2021 2141 4-Methyl-2-pentanone 100 110 1 106 70-130 11/09/2021 2141 Methylene chloride 50 49 1 98 70-130 11/09/2021 2141 Styrene 50 53 1 107 70-130 11/09/2021 2141 1,1,1,2-Tetrachloroethane 50 50 1 99 70-130 11/09/2021 2141 1,1,2,2-Tetrachloroethane 50 45 1 90 70-130 11/09/2021 2141 Tetrachloroethene 50 48 1 96 70-130 11/09/2021 2141 Toluene 50 48 1 96 70-130 11/09/2021 2141 1,1,1-Trichloroethane 50 47 1 95 70-130 11/09/2021 2141 1,1,2-Trichloroethane 50 48 1 95 70-130 11/09/2021 2141 Trichloroethene 50 46 1 91 70-130 11/09/2021 2141 Trichlorofluoromethane 50 49 1 97 70-130 11/09/2021 2141 1,2,3-Trichloropropane 50 46 1 93 70-130 11/09/2021 2141 Vinyl chloride 50 40 1 80 70-130 11/09/2021 2141 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 113 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21878-002 Matrix: Aqueous Batch:21878 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Xylenes (total) 100 100 1 102 70-130 11/09/2021 2141 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 91 70-130 1,2-Dichloroethane-d4 86 70-130 Toluene-d8 91 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 114 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21878-001 Matrix: Aqueous Batch: 21878 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 11/09/2021 2245 Acrylonitrile ND 1 20 0.80 ug/L 11/09/2021 2245 Benzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromodichloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromoform ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 11/09/2021 2245 Carbon disulfide ND 1 1.0 0.40 ug/L 11/09/2021 2245 Carbon tetrachloride ND 1 1.0 0.40 ug/L 11/09/2021 2245 Chlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Chloroethane ND 1 2.0 0.40 ug/L 11/09/2021 2245 Chloroform ND 1 1.0 0.40 ug/L 11/09/2021 2245 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 11/09/2021 2245 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 11/09/2021 2245 Dibromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 11/09/2021 2245 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 11/09/2021 2245 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 11/09/2021 2245 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 2245 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 2245 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Ethylbenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 2-Hexanone ND 1 10 2.0 ug/L 11/09/2021 2245 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 11/09/2021 2245 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 11/09/2021 2245 Methylene chloride ND 1 1.0 0.40 ug/L 11/09/2021 2245 Styrene ND 1 1.0 0.41 ug/L 11/09/2021 2245 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Tetrachloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Tetrahydrofuran ND 1 5.0 1.0 ug/L 11/09/2021 2245 Toluene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Trichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 2245 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 115 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21878-001 Matrix: Aqueous Batch:21878 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl chloride ND 1 1.0 0.40 ug/L 11/09/2021 2245 Xylenes (total) ND 1 1.0 0.40 ug/L 11/09/2021 2245 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 90 70-130 1,2-Dichloroethane-d4 97 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 116 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21878-002 Matrix: Aqueous Batch: 21878 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 78 1 78 60-140 11/09/2021 2141 Acrylonitrile 100 86 1 86 70-130 11/09/2021 2141 Benzene 50 46 1 93 70-130 11/09/2021 2141 Bromochloromethane 50 45 1 90 70-130 11/09/2021 2141 Bromodichloromethane 50 49 1 97 70-130 11/09/2021 2141 Bromoform 50 54 1 109 70-130 11/09/2021 2141 Bromomethane (Methyl bromide) 50 43 1 87 70-130 11/09/2021 2141 Carbon disulfide 50 50 1 99 70-130 11/09/2021 2141 Carbon tetrachloride 50 47 1 95 70-130 11/09/2021 2141 Chlorobenzene 50 48 1 97 70-130 11/09/2021 2141 Chloroethane 50 42 1 84 70-130 11/09/2021 2141 Chloroform 50 43 1 86 70-130 11/09/2021 2141 Chloromethane (Methyl chloride) 50 38 1 76 60-140 11/09/2021 2141 1,2-Dibromo-3-chloropropane (DBCP) 50 47 1 94 70-130 11/09/2021 2141 Dibromochloromethane 50 51 1 102 70-130 11/09/2021 2141 1,2-Dibromoethane (EDB) 50 50 1 100 70-130 11/09/2021 2141 Dibromomethane (Methylene bromide) 50 46 1 93 70-130 11/09/2021 2141 trans- 1,4-Dichloro-2-butene 50 46 1 91 70-130 11/09/2021 2141 1,2-Dichlorobenzene 50 48 1 96 70-130 11/09/2021 2141 1,4-Dichlorobenzene 50 45 1 90 70-130 11/09/2021 2141 1,1-Dichloroethane 50 43 1 86 70-130 11/09/2021 2141 1,2-Dichloroethane 50 45 1 90 70-130 11/09/2021 2141 1,1-Dichloroethene 50 47 1 93 70-130 11/09/2021 2141 cis- 1,2-Dichloroethene 50 43 1 87 70-130 11/09/2021 2141 trans- 1,2-Dichloroethene 50 43 1 87 70-130 11/09/2021 2141 1,2-Dichloropropane 50 49 1 98 70-130 11/09/2021 2141 cis- 1,3-Dichloropropene 50 54 1 108 70-130 11/09/2021 2141 trans- 1,3-Dichloropropene 50 48 1 96 70-130 11/09/2021 2141 Ethylbenzene 50 49 1 98 70-130 11/09/2021 2141 2-Hexanone 100 100 1 103 70-130 11/09/2021 2141 Methyl iodide (lodomethane) 50 50 1 100 70-130 11/09/2021 2141 4-Methyl-2-pentanone 100 110 1 106 70-130 11/09/2021 2141 Methylene chloride 50 49 1 98 70-130 11/09/2021 2141 Styrene 50 53 1 107 70-130 11/09/2021 2141 1,1,1,2-Tetrachloroethane 50 50 1 99 70-130 11/09/2021 2141 1,1,2,2-Tetrachloroethane 50 45 1 90 70-130 11/09/2021 2141 Tetrachloroethene 50 48 1 96 70-130 11/09/2021 2141 Tetrahydrofuran 50 44 1 88 70-130 11/09/2021 2141 Toluene 50 48 1 96 70-130 11/09/2021 2141 1,1,1-Trichloroethane 50 47 1 95 70-130 11/09/2021 2141 1,1,2-Trichloroethane 50 48 1 95 70-130 11/09/2021 2141 Trichloroethene 50 46 1 91 70-130 11/09/2021 2141 Trichlorofluoromethane 50 49 1 97 70-130 11/09/2021 2141 1,2,3-Trichloropropane 50 46 1 93 70-130 11/09/2021 2141 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 117 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21878-002 Matrix: Aqueous Batch:21878 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl chloride 50 40 1 80 70-130 11/09/2021 2141 Xylenes (total) 100 100 1 102 70-130 11/09/2021 2141 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 91 70-130 1,2-Dichloroethane-d4 86 70-130 Toluene-d8 91 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 118 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ22207-001 Matrix: Aqueous Batch: 22207 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 11/11/2021 1006 Acrylonitrile ND 1 20 0.80 ug/L 11/11/2021 1006 Benzene ND 1 1.0 0.40 ug/L 11/11/2021 1006 Bromochloromethane ND 1 1.0 0.40 ug/L 11/11/2021 1006 Bromodichloromethane ND 1 1.0 0.40 ug/L 11/11/2021 1006 Bromoform ND 1 1.0 0.40 ug/L 11/11/2021 1006 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 11/11/2021 1006 2-Butanone (MEK) ND 1 10 2.0 ug/L 11/11/2021 1006 Carbon disulfide ND 1 1.0 0.40 ug/L 11/11/2021 1006 Carbon tetrachloride ND 1 1.0 0.40 ug/L 11/11/2021 1006 Chlorobenzene ND 1 1.0 0.40 ug/L 11/11/2021 1006 Chloroethane ND 1 2.0 0.40 ug/L 11/11/2021 1006 Chloroform ND 1 1.0 0.40 ug/L 11/11/2021 1006 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 11/11/2021 1006 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 11/11/2021 1006 Dibromochloromethane ND 1 1.0 0.40 ug/L 11/11/2021 1006 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 11/11/2021 1006 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 11/11/2021 1006 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 11/11/2021 1006 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/11/2021 1006 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/11/2021 1006 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 11/11/2021 1006 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 11/11/2021 1006 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 11/11/2021 1006 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/11/2021 1006 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/11/2021 1006 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 11/11/2021 1006 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/11/2021 1006 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/11/2021 1006 Ethylbenzene ND 1 1.0 0.40 ug/L 11/11/2021 1006 2-Hexanone ND 1 10 2.0 ug/L 11/11/2021 1006 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 11/11/2021 1006 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 11/11/2021 1006 Methylene chloride ND 1 1.0 0.40 ug/L 11/11/2021 1006 Styrene ND 1 1.0 0.41 ug/L 11/11/2021 1006 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/11/2021 1006 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/11/2021 1006 Tetrachloroethene ND 1 1.0 0.40 ug/L 11/11/2021 1006 Toluene ND 1 1.0 0.40 ug/L 11/11/2021 1006 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 11/11/2021 1006 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 11/11/2021 1006 Trichloroethene ND 1 1.0 0.40 ug/L 11/11/2021 1006 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 11/11/2021 1006 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 11/11/2021 1006 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 119 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ22207-001 Matrix: Aqueous Batch:22207 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 11/11/2021 1006 Vinyl chloride ND 1 1.0 0.40 ug/L 11/11/2021 1006 Xylenes (total) ND 1 1.0 0.40 ug/L 11/11/2021 1006 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 87 70-130 1,2-Dichloroethane-d4 102 70-130 Toluene-d8 91 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 120 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ22207-002 Matrix: Aqueous Batch: 22207 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 140 1 136 60-140 11/11/2021 0902 Acrylonitrile 100 93 1 93 70-130 11/11/2021 0902 Benzene 50 49 1 99 70-130 11/11/2021 0902 Bromochloromethane 50 46 1 93 70-130 11/11/2021 0902 Bromodichloromethane 50 44 1 89 70-130 11/11/2021 0902 Bromoform 50 50 1 99 70-130 11/11/2021 0902 Bromomethane (Methyl bromide) 50 48 1 96 70-130 11/11/2021 0902 2-Butanone (MEK) 100 140 N 1 136 70-130 11/11/2021 0902 Carbon disulfide 50 46 1 93 70-130 11/11/2021 0902 Carbon tetrachloride 50 45 1 90 70-130 11/11/2021 0902 Chlorobenzene 50 48 1 97 70-130 11/11/2021 0902 Chloroethane 50 50 1 101 70-130 11/11/2021 0902 Chloroform 50 52 1 104 70-130 11/11/2021 0902 Chloromethane (Methyl chloride) 50 49 1 99 60-140 11/11/2021 0902 1,2-Dibromo-3-chloropropane (DBCP) 50 44 1 87 70-130 11/11/2021 0902 Dibromochloromethane 50 49 1 97 70-130 11/11/2021 0902 1,2-Dibromoethane (EDB) 50 50 1 100 70-130 11/11/2021 0902 Dibromomethane (Methylene bromide) 50 45 1 91 70-130 11/11/2021 0902 trans- 1,4-Dichloro-2-butene 50 48 1 96 70-130 11/11/2021 0902 1,2-Dichlorobenzene 50 47 1 94 70-130 11/11/2021 0902 1,4-Dichlorobenzene 50 46 1 92 70-130 11/11/2021 0902 1,1-Dichloroethane 50 45 1 89 70-130 11/11/2021 0902 1,2-Dichloroethane 50 46 1 92 70-130 11/11/2021 0902 1,1-Dichloroethene 50 49 1 97 70-130 11/11/2021 0902 cis- 1,2-Dichloroethene 50 49 1 97 70-130 11/11/2021 0902 trans- 1,2-Dichloroethene 50 46 1 93 70-130 11/11/2021 0902 1,2-Dichloropropane 50 44 1 89 70-130 11/11/2021 0902 cis- 1,3-Dichloropropene 50 50 1 101 70-130 11/11/2021 0902 trans- 1,3-Dichloropropene 50 50 1 100 70-130 11/11/2021 0902 Ethylbenzene 50 53 1 105 70-130 11/11/2021 0902 2-Hexanone 100 95 1 95 70-130 11/11/2021 0902 Methyl iodide (lodomethane) 50 51 1 102 70-130 11/11/2021 0902 4-Methyl-2-pentanone 100 93 1 93 70-130 11/11/2021 0902 Methylene chloride 50 47 1 93 70-130 11/11/2021 0902 Styrene 50 49 1 98 70-130 11/11/2021 0902 1,1,1,2-Tetrachloroethane 50 48 1 96 70-130 11/11/2021 0902 1,1,2,2-Tetrachloroethane 50 50 1 100 70-130 11/11/2021 0902 Tetrachloroethene 50 50 1 100 70-130 11/11/2021 0902 Toluene 50 53 1 106 70-130 11/11/2021 0902 1,1,1-Trichloroethane 50 47 1 93 70-130 11/11/2021 0902 1,1,2-Trichloroethane 50 47 1 94 70-130 11/11/2021 0902 Trichloroethene 50 46 1 93 70-130 11/11/2021 0902 Trichlorofluoromethane 50 45 1 89 70-130 11/11/2021 0902 1,2,3-Trichloropropane 50 47 1 93 70-130 11/11/2021 0902 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 121 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ22207-002 Matrix: Aqueous Batch:22207 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 48 1 96 60-140 11/11/2021 0902 Vinyl chloride 50 47 1 94 70-130 11/11/2021 0902 Xylenes (total) 100 94 1 94 70-130 11/11/2021 0902 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 104 70-130 1,2-Dichloroethane-d4 92 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 122 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ22328-001 Matrix: Aqueous Batch:22328 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 2-Butanone (MEK) ND 1 10 2.0 ug/L 11/12/2021 1055 Vinyl acetate ND 1 5.0 1.2 ug/L 11/12/2021 1055 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 98 70-130 1,2-Dichloroethane-d4 105 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 123 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ22328-002 Matrix: Aqueous Batch:22328 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 2-Butanone (MEK) 100 110 1 109 70-130 11/12/2021 0953 Vinyl acetate 50 46 1 92 60-140 11/12/2021 0953 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 95 70-130 Toluene-d8 88 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 124 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ22328-001 Matrix: Aqueous Batch:22328 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 11/12/2021 1055 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 98 70-130 1,2-Dichloroethane-d4 105 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 125 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ22328-002 Matrix: Aqueous Batch:22328 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 46 1 92 60-140 11/12/2021 0953 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 95 70-130 Toluene-d8 88 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 126 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ24540-001 Matrix: Aqueous Batch:24540 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 2-Butanone (MEK) ND 1 10 2.0 ug/L 12/03/2021 1027 Vinyl acetate ND 1 5.0 1.2 ug/L 12/03/2021 1027 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 123 70-130 Toluene-d8 107 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 127 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ24540-002 Matrix: Aqueous Batch:24540 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 2-Butanone (MEK) 100 120 1 119 70-130 12/03/2021 0923 Vinyl acetate 50 53 1 105 60-140 12/03/2021 0923 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 99 70-130 1,2-Dichloroethane-d4 102 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 128 of 149 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ24540-001 Matrix: Aqueous Batch:24540 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 2-Butanone (MEK) ND 1 10 2.0 ug/L 12/03/2021 1027 Vinyl acetate ND 1 5.0 1.2 ug/L 12/03/2021 1027 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 123 70-130 Toluene-d8 107 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 129 of 149 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ24540-002 Matrix: Aqueous Batch:24540 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 2-Butanone (MEK) 100 120 1 119 70-130 12/03/2021 0923 Vinyl acetate 50 53 1 105 60-140 12/03/2021 0923 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 99 70-130 1,2-Dichloroethane-d4 102 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 130 of 149 ICP-MS Metals - MB Sample ID: WQ20754-001 Matrix: Aqueous Batch: 20754 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/02/2021 0357 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 11/02/2021 1749 Arsenic ND 1 2.0 1.3 ug/L 11/02/2021 1749 Barium ND 1 5.0 1.3 ug/L 11/02/2021 1749 Beryllium ND 1 0.40 0.15 ug/L 11/02/2021 1749 Cadmium ND 1 0.50 0.13 ug/L 11/02/2021 1749 Chromium ND 1 5.0 1.3 ug/L 11/02/2021 1749 Cobalt ND 1 5.0 1.3 ug/L 11/02/2021 1749 Copper ND 1 5.0 1.3 ug/L 11/02/2021 1749 Iron ND 1 50 13 ug/L 11/02/2021 1749 Lead ND 1 1.0 0.25 ug/L 11/02/2021 1749 Manganese ND 1 5.0 1.3 ug/L 11/02/2021 1749 Nickel ND 1 5.0 1.3 ug/L 11/02/2021 1749 Selenium ND 1 5.0 1.3 ug/L 11/02/2021 1749 Silver ND 1 1.0 0.25 ug/L 11/02/2021 1749 Thallium ND 1 0.50 0.15 ug/L 11/02/2021 1749 Vanadium ND 1 5.0 2.5 ug/L 11/02/2021 1749 Zinc ND 1 10 2.5 ug/L 11/02/2021 1749 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 131 of 149 ICP-MS Metals - LCS Sample ID: WQ20754-002 Matrix: Aqueous Batch: 20754 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/02/2021 0357 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 98 1 98 80-120 11/02/2021 1751 Arsenic 100 100 1 102 80-120 11/02/2021 1751 Barium 100 97 1 97 80-120 11/02/2021 1751 Beryllium 100 99 1 99 80-120 11/02/2021 1751 Cadmium 100 100 1 101 80-120 11/02/2021 1751 Chromium 100 100 1 104 80-120 11/02/2021 1751 Cobalt 100 100 1 101 80-120 11/02/2021 1751 Copper 100 110 1 107 80-120 11/02/2021 1751 Iron 1000 980 1 98 80-120 11/02/2021 1751 Lead 100 100 1 101 80-120 11/02/2021 1751 Manganese 100 100 1 102 80-120 11/02/2021 1751 Nickel 100 110 1 105 80-120 11/02/2021 1751 Selenium 100 100 1 104 80-120 11/02/2021 1751 Silver 100 96 1 96 80-120 11/02/2021 1751 Thallium 100 96 1 96 80-120 11/02/2021 1751 Vanadium 100 100 1 102 80-120 11/02/2021 1751 Zinc 100 100 1 103 80-120 11/02/2021 1751 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 132 of 149 ICP-MS Metals - MB Sample ID: WQ21233-001 Matrix: Aqueous Batch: 21233 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/04/2021 0914 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 11/05/2021 1235 Arsenic ND 1 2.0 1.3 ug/L 11/05/2021 1235 Barium ND 1 5.0 1.3 ug/L 11/05/2021 1235 Beryllium ND 1 0.40 0.15 ug/L 11/05/2021 1235 Cadmium ND 1 0.50 0.13 ug/L 11/05/2021 1235 Chromium ND 1 5.0 1.3 ug/L 11/05/2021 1235 Cobalt ND 1 5.0 1.3 ug/L 11/05/2021 1235 Copper ND 1 5.0 1.3 ug/L 11/05/2021 1235 Iron 15 J 1 50 13 ug/L 11105/20211235 Lead ND 1 1.0 0.25 ug/L 11/05/2021 1235 Manganese ND 1 5.0 1.3 ug/L 11/05/2021 1235 Nickel ND 1 5.0 1.3 ug/L 11/05/2021 1235 Selenium ND 1 5.0 1.3 ug/L 11/05/2021 1235 Silver ND 1 1.0 0.25 ug/L 11/05/2021 1235 Thallium ND 1 0.50 0.15 ug/L 11/05/2021 1235 Vanadium ND 1 5.0 2.5 ug/L 11/05/2021 1235 Zinc ND 1 10 2.5 ug/L 11/05/2021 1235 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 133 of 149 ICP-MS Metals - LCS Sample ID: WQ21233-002 Matrix: Aqueous Batch: 21233 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/04/2021 0914 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 98 1 98 80-120 11/05/2021 1237 Arsenic 100 100 1 103 80-120 11/05/2021 1237 Barium 100 96 1 96 80-120 11/05/2021 1237 Beryllium 100 110 1 113 80-120 11/05/2021 1237 Cadmium 100 100 1 102 80-120 11/05/2021 1237 Chromium 100 100 1 104 80-120 11/05/2021 1237 Cobalt 100 100 1 102 80-120 11/05/2021 1237 Copper 100 110 1 108 80-120 11/05/2021 1237 Iron 1000 1000 1 101 80-120 11/05/2021 1237 Lead 100 99 1 99 80-120 11/05/2021 1237 Manganese 100 100 1 105 80-120 11/05/2021 1237 Nickel 100 110 1 107 80-120 11/05/2021 1237 Selenium 100 94 1 94 80-120 11/05/2021 1237 Silver 100 98 1 98 80-120 11/05/2021 1237 Thallium 100 97 1 97 80-120 11/05/2021 1237 Vanadium 100 100 1 104 80-120 11/05/2021 1237 Zinc 100 100 1 103 80-120 11/05/2021 1237 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 134 of 149 ICP-MS Metals - MB Sample ID: WQ21241-001 Matrix: Aqueous Batch: 21241 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/07/2021 0954 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 11/08/2021 1659 Arsenic ND 1 2.0 1.3 ug/L 11/08/2021 1659 Barium ND 1 5.0 1.3 ug/L 11/08/2021 1659 Beryllium ND 1 0.40 0.15 ug/L 11/08/2021 1659 Cadmium ND 1 0.50 0.13 ug/L 11/08/2021 1659 Chromium ND 1 5.0 1.3 ug/L 11/08/2021 1659 Cobalt ND 1 5.0 1.3 ug/L 11/08/2021 1659 Copper ND 1 5.0 1.3 ug/L 11/08/2021 1659 Lead ND 1 1.0 0.25 ug/L 11/08/2021 1659 Nickel ND 1 5.0 1.3 ug/L 11/08/2021 1659 Selenium ND 1 5.0 1.3 ug/L 11/08/2021 1659 Silver ND 1 1.0 0.25 ug/L 11/08/2021 1659 Thallium ND 1 0.50 0.15 ug/L 11/08/2021 1659 Vanadium ND 1 5.0 2.5 ug/L 11/08/2021 1659 Zinc 3.2 J 1 10 2.5 ug/L 11/08/2021 1659 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 135 of 149 ICP-MS Metals - LCS Sample ID: WQ21241-002 Matrix: Aqueous Batch: 21241 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/07/2021 0954 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 97 1 97 80-120 11/08/2021 1701 Arsenic 100 99 1 99 80-120 11/08/2021 1701 Barium 100 93 1 93 80-120 11/08/2021 1701 Beryllium 100 110 1 105 80-120 11/08/2021 1701 Cadmium 100 100 1 100 80-120 11/08/2021 1701 Chromium 100 100 1 101 80-120 11/08/2021 1701 Cobalt 100 99 1 99 80-120 11/08/2021 1701 Copper 100 110 1 106 80-120 11/08/2021 1701 Lead 100 95 1 95 80-120 11/08/2021 1701 Nickel 100 100 1 103 80-120 11/08/2021 1701 Selenium 100 97 1 97 80-120 11/08/2021 1701 Silver 100 97 1 97 80-120 11/08/2021 1701 Thallium 100 93 1 93 80-120 11/08/2021 1701 Vanadium 100 100 1 101 80-120 11/08/2021 1701 Zinc 100 100 1 102 80-120 11/08/2021 1701 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 136 of 149 CVAA -MB Sample ID: WQ21630-001 Matrix: Aqueous Batch: 21630 Prep Method: Analytical Method: 7470A Prep Date: 11/08/2021 1655 Parameter Result Q Dil LOQ DL Units Analysis Date Mercury ND 1 0.00020 0.000091 mg/L 11/09/2021 1526 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 137 of 149 CVAA - LCS Sample ID: WQ21630-002 Matrix: Aqueous Batch: 21630 Prep Method: Analytical Method: 7470A Prep Date: 11/08/2021 1655 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Mercury 0.0020 0.0020 1 100 80-120 11/09/2021 1529 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 138 of 149 CVAA - MS Sample ID: WJ30017-001MS Matrix: Aqueous Batch: 21630 Prep Method: Analytical Method: 7470A Prep Date: 11/08/2021 1655 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Mercury ND 0.0020 0.0020 1 98 80-120 11/09/2021 1553 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 139 of 149 CVAA - MSD Sample ID: WJ30017-001MD Matrix: Aqueous Batch: 21630 Prep Method: Analytical Method: 7470A Prep Date: 11/08/2021 1655 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Mercury ND 0.0020 0.0020 1 101 3.1 80-120 20 11/09/2021 1556 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 140 of 149 Chain of Custody and Miscellaneous Documents Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 141 of 149 �0 <CD m D ;v v CD C - 0 °� rn CD v� o CD N � r r N o ° c m 3 Q •c m y 1 3 CD V C N 0 CD CD o, V � y -4� V 0 O CD O y -n z3 m � co W E3 C/�r I3� ILfI�I��L�LYJ� �J Glfy Sda�r L'irG'# �miocr A43rrrr Ao &Wr xe OD i fl,a%Tj,-1 �Gr, � Pon ilia BufkLJe. myte C Mbtr" cn cn^.h'tJ PACE ANALYTICAL SERVICES, LLC 113E Vantage Post Dm,e , yj,-sl Cbdurr.bid, 5C Oh72 lelaahang No. FM-791-07� Q I -ON No. 60 791-9111 Number ? f } 11 4vww.;Jarjdabs.r;gm -- I IL !leki;J A+ris"_rwf dada I Jrlaif'br %yw- LVFrc��x,SLvr , wa (r f �� — ] It' 7'u-ArvwxlTfi;+Re4+,rroafMrfkd'�apves+'p1xl,7�bsdmr,Qdf'sdR1T) s,yz,,psa! Sfendp" z. J3RfJr.� rid � { :. S° 7_�: 5• ,�. fffuMYyxn'S7dtl r/ L4r,0 iil7Jr7 fF JkGJk3: A s&m tev WC rel80ed [Of- lbiff weeks irerrr receJjpt -- i�FFiES$.0herflrrangeni care J Ace- DR3MOrd roN. V-"TF & YEILOVI-Ftl%i J .@: f ete;p riSiiJ � r!4:C(91: r'JhR{•fi5ilJ4 7rTrf t'�pJ �rr,'u �+1�C.rh �9Q fflnQrg 6p3i.Y� iw rJL'S�Ygp� 1 f WJ 0017 k l r — L . /Y. - f 5nic +erJJJad . dkrWfi'srk,rJ 4C — f-'nl-jirr;e�lp SY.�,rcllAtlt !''Porgar, U.,bo'cu i. r�e[91Jed by fYrJ2 _ f 3. fii9v6JVecf Jay A raoyracar�1rbr LAErJ arr.Sae (�'sAaJ zc�r,J� garJr, ,4 — rfC ke �sp4 - � 7Cwrti� � •. � �: �77�CWY�nrf.em65Y: fLifrAl.7i\'2-j7 D m D D r m 0 m cn 1 I �0 < ro m D m v CD C - v nn °' rn ro v� o m N � r m n _CD 3 Q� m y 1 3 0CD V C N 0 W CDo, V � CD �C -4� V 0 O CD y T z3 v� X �- co O w m fo 0 E3 { PACE ANALYTICAL F*RVIUE , LLC }� log Van!49a Pain# Cmte • Wes' c:ortf,•n3k SC 29172 re.aphono mo. aw-791 97Dp Fax No. 8�4# 791.gyy t 'A'V�'w_p�calah�.�nm Addr6s5 Cory riC,7W� rao- Llx�d..... ��,�r3 "cNy'rahxr - r — _ . Prtrrfco AV -.Me FIF llirrra M c, r LF F. 9. Akk — �" AS71o'ur — &irrra %e fDI Sc, ona: rUdmmcu x Ym n s Ilan+wee,araac+��da+aeranaul¢raoaAbreoara�� �syy� g . — � M k 10 L. 7irF� .srowld TF^He R rr ' � 1.. I I BgiN•e_frr�erraA�'tawJfep,rn��fore�prcrrf�,f�lr� 5krrr�{a.7,yvasd� Sf8frd9fd 6�F (SpRGif}f ry L RiNJPL ra rxr.w.• . ` pj• ! Tc—�,20 r` f -- fF Yl tiGf a�FL, ,9.Rrirbiq�:'s�icdtjr - owG ...r� ftii re: flip ;c7,fS�J s ar,a Mrairied fur lour sv r front rocapt [+ra+e olrrar axangoments ers rrwefa. =rPID- TJOr' L'VFHTR 8 YSLCOWR .,, 0 Ndl S—c�n FWjwrp.wbjWrr! G."y Number 2 7 4? 1 JZ�"VtVflS NC.. I �,nad L L1,1e All,AFl9�y&t: rtjraahR-,rwfTQlaFML:-LYnfWi-f,rl �r Rxswv�fv L•7js' . 1 n, ! 018 paas9E v Mazam food 6-,%Jwr I h'9q-Haeard fWinn hle �' 5tin'riFint i ..-cQM :.r Unknown by 4. Lab LAB uswy ,{y rTecWYfp� or7 ke (ti^. iLw) f 'r� AU ac Igegru[r�a,,� r`r} i7t�ry i mra Qr. r• Tx p 'Z T�w +q�'V ffkrA -3y 11w d.16:ar:onrNN4.5T."��. +,2�L43N: ^1 U) m 0 m cn r r 0 PACE ANALYTICAL SERVICES. LLC Sant/ $ Receipt Checklist (SBc) (ME0131ac-15) ltevised=9 29f FOCI] J�CAfdl�yfic�l 1 suing AuLhrsrfty, Pace EW - VVCOM Page 7 ❑f 2 Sam le Receilpt Checklist (SR Eli nt 6Lf Cale, InTll�!ed b !date: IR{32 f 1413 alm2i k1ftl5OfJvt-cip,L: Par.: 01ient I IIJP$ PedLac i]lh e: No I. Were CUStody ONS presenl On the cot,le•r? ye$ ND d NA 2. If custod wAls iere resent, ware they itttt7ct ar.e: unbrn4n? H Strip E� R ID: 2t$= -- Chlorine Sizip I_ NA_ Te51Cd 3}' a1,02 Orighlal 4.3 b—]PL;Fdwre upoa rcmipt er Ucrived ( omccted) ll-TemtLrre upon ret.d:pt %Solid Sr_ap-C't-p ID-. �'l`A — _,d.R `hC NA _ jWA oC NA }MA -C `th INA r� h4edi0d: iemperatureltlank I pinst II ks IRQu-1 TD: ' ]R Owl Catee#ia.r Faurr- aC hMeIEI[lu ofaxwlanr; Q Wet Ice 0 Ice Pa ks ❑ Ire n Non -a' — Yes ❑ T\o LdNA 1 If tC1KPL;uL.Ire. a11,V C:LPQJ4% c)ceed01 4.0°C, vas P jert Manager ? jt=fled? — PM yrt'sls Tlntif b.-! OW i ME! iI { fh4A-tc4'pCfl (ciirle un,). Yew EINU l+tA.4, Is th:: comer e! J cv-wrier% paEtiIK:A ip unzched 19 t1r5 fprru'fi Yrs No 5. �VYrG, proper cry cvdtues (rcl;nquished' ccc[ved) fol [mwaa? d 7e;� Nol 6. sample ID Tisfed on the COC? J Yes NLO 7. R'+ same=e IJ listed on nJ! sarrpl C4111$irtCr�? Y1* N0 time listed an tt<e CO C7 ❑ YO No 9_ Was —Ir.1 1 d 'e 8e time listed On all In-P.1e coulainurs? ✓ Yes i Nv 10, Did all corttaLmf label irL implion P. date, dmt) ftgree wilh the {;f1o? Yes NQ 11, Were tells to be [performed Iistc+d on the MC" 17.DYes a arriv-e in the prop --Fr aMMLIcrw for each test andlor in good core tiai (unbr4ca, lids on, W.j?' wr Yes lva 13. Was adoquare sample vol wme zi-y0Ible? � esl No 14. Wem rll samp.ke received wirhin %s t[1Ghold ingtine or49lion rs, whicktcrt`rflames first Yns I I J Net 15. W re mi ' sump contabters missin 'excess (cimic one) Samples 1hlk t Jis!ed on COC•? Yes A'o ❑NA 16. For VOA aped R -175 mnplaq, were ba:ita[e,s presant?"pr�size" (Velar 5mT1 it dialtt4 IH Ony Of the VrOA V e 0 yus No NA '�. � ere all DRO taWnutrient S= Ics receivexl at a p4 #f < 2? s No � _�1 � 19. Were LL[I cyanid., Sant Des. umcive 1 at a H > 12 and suiflde ��mplcs reorived 8L a pH ;;� 9 Yes F-] No UjiNA 19, Were d aapp'i s � Jff,�l !{N c}+a��it6a'phennll�i�5_]t502G.3 (< 0 #m 1 s�rm les Fr - residual altlnr 110 Yes C] No MNA 20, W re elienl reina%kslrcquests (1,e. requemd di]113600, TV[&rMSD designations, etc__.} cdrracrl}r trar.srt;ribed rrum the COC into t'he r�1.wrjerrt. sectinr in LAMS? � Yrs No 21. Was the taflty -rL ber [[Bred on the cor lairler l I't IY w:s, Quolc 4S�lnnple Prt:aervatEon I�[41i]Mt },� completed any satnp[t{s} i,scon"octJy Jx��'nw�ed nr +�•itlti tteltdspace-) 5 rtp[e(s) � xere receiv rl in cso1'l tly P serrv'Od ad w ncre ar j15ted a wrrdIngly in sample »wing wish mL o circle oil = H2SC14. 111403, HC-`I, Na01{ usit],g SR 17mc of psl crvat[an `� tf morn t]tia1 ne a preservative is nm&d, please note in the connrt ri.fi below, MA . anpJ°(s) _were retxi wed with k$tPTcs :-6 mrtl it dia3rIL'twr. Sumples(s;) were rect[ved with TRC > 0.5 _ngA, (If i+19 is Ouy jjr�d j je1e .lusted aGOordh1gly in sample receivi:tg a ith S iulr'hioa:rlfmo (NF1,5zt"1a) witil Shealy ID: NA SR hxrocde rijbe[s apprir~d bu 1r4t;2 fate: IDi30"� I f:�nuleuts; ..— Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 144 of 149 �0 <CD m D ;v v C m vv O' vl m v� <0 CD CD � r r N_ 0 o O � C 3 ccD �4 v� 0 ? �CD V C N 0 O W CDo� V � �y m �o V 0 O CD oy b � O O V A � n E3 -.1001 aceAnafytical I .4Jclrats CO a(,(,j=r xw-,& ,kn d v.%. PACE ANALYTICAL SERVICES, LLG 06 V rrTa Pourl 4r.ti e - VJsst Crll a mbia, SC 29172 Telepiionle No. 6Q3-70i-9700 Fax NO-803-791-9111 ww,v.paaelabs.=m £dfr�6E'� S tore PMn14f+ i1Lvn� S --- fs04 r:c flW CVFO- x br hexveli� TM'4 n' wsbree �r to fbeaarr5'nada aae�,a.. 0=.:s7 4Aoray) s `ir _a' 101 _ � ill i 7f,rn Anr,irHfl7br7C j ir�� fFxBRr JaG WMW Fft-"'Jrac'-_14rwiw B7T.j !?Nri&S dt,' QFmr srona„w : mish r'F:dr4y) - Pmum raaknr 1 FA i+urs! tY 1 Vass ae% � . FiP.l^gW,xn ;Y M" Tbrra rJere TM1voe �. RewWtshEeby 4, q�i �y � �• - 7bl:a lrfol�; ,4 sa,�185 dry rea;ae;ed for four �+�eks fix�rr� racerot L'r]iC53 OtFiR aarTPfrgpfFedr]!S Bore.'- fFRcP- Eq�MrDUTfCW!VA27ES'ftl.tQW-P7 lffndaf+ral:x}'rti'hgamrpNsf,i�L''J�FX9ad+ 7apf ors fib. f F-e,sr' mumber a. 2 7 4 0 gum hla ['LUa!n7 am rr ro" kutd n ;g- 9 . i I 7 1 ZX 4�9 rh 'i j DO18 1 % ii < Ii — FoLeaar,--"idmMo .. WGf3Bau�irrwvi� LlD N"Fr amrd i': F411nm18e 5kn irdUld 'i Prrann 4 J Unk jmm — 1. Ha oVadb) ove Ara 2. flaasF by .. Dive 'Tive a fnaoeawa �i. ���t, 7baa 4- kOxMuYrsrrivrtiby Jsf� 7kne 68< JA9LOSE 10ntir T�Lr4as.AiVA Y rd #i�x+'w art Jlca ;C�Yac��' kre k Pacar P6ca;Jr -ram._-. D m z D n I— 70 0 m cn r 0 N Q E3 a eAnaly al� f OM � L P PACE ANALYTICAL S ERVI C ES, LtC a D6 Viant€ge Poini D vo • Wni t C:OIUm4:d. SC 29172 TulQplloro No. 80J-7f 1-9704 ��x No, 9C YJ1 9111 utvw.pacelabs,eurE, P4" AD CC*+r&g -kkpn w Mb (F•eLxi' Number -'!„ 7 4 - Q,.ara ME 6A1ryN.!t!T . 17a& ie .. ArIPJY-4+ 6A [♦nrdi 6'41 ry MCA9 909C9 lF RWW) I� k .i2y m :'dare z4c .Made Xs LM.-nohOMO ProrjeceNl.Oe VV +�00�`Y,.i,]�Jk+1 ib a 0;. Wns" ifsa FsasNvmh� d i Errs !€ Amarks,'AWilIA (Lna�.4aaarJlegrr�OarcpLecvrnsriedr7wr9[,TRi ?rcji} {+s1r! _ k. T i I wm, 5 a UG r eauffU6n, IM 711FFf �4'��1A176134rfnrmc'fFoer+alaa�r�wP11���+h�d f9rexh'�ue��9r.J3sr.'rv+s '�'�Ros�l P�.s.�rre h'ararG;dsnr�fcwlinr f°Y!'k Sr9n[4.+,i Hog])( prifyJ - i.J i4i2awpjr LW+ - J]'.sml;al GyLaC i5Dn-I luard I'i Fl_,arr2Llu : SBIn rime[ C Poi9771 llrlmarn �7bne i. fix.99by Oe, T1me Dare Tme 2 mxwa4aa by EarC Nam 3. ,4Cwr9uilshe+d 6y pt;C T♦r s 3 hmawvsd bk- D063 ] une . Rrdurr wllmrf by li9�P iLng a, in6orsRarT•recelr¢dvy - - ' ?'rfiP �¢i $�i fiA1 a F—e eroed For (UEf� W6eA + from. reCeiv 1.49 USE OF&Y lxrrefis o herafr 6mc[rr sre rrl2de. parr i-.r {atc l 3es fik- MyR1 VTiW , WgTZ 3 YLLL�4W-RSNfa.b j%Vh]f8a-y-M.h SWV- J, flWK-t,i;kk .k-nf CAA .y AkC+riaera! lLLnP der_ A1EOU0rd7L i D m D D n D r m [A7 m cn r 0 PACE ANALYTICAL SERVICES, LLC Samples F1QCQipk Checklist IS111C] (MC0018C.15) RevlsEd:9f29/202.0 aAnaii4 al Is5uiug.Au.ncriLy: Pace ENV -1L"CO'_ Page 1 of 1 Sample RcceiPt Checklist (SRC) Client: xr.F C'+xFler 1rL n Lud byldatt: .l r; I tlC21242L Le- ; , WJ"'J7 t1Ulli K lrTeansofroceipl: Waco Client UPS Fedf Oil - 4' Nn I I 1. W= clrAodty seals yFJr-scnt on 1:1r, cooler? ti eaF1No NA 2. If cusLvdy —15 were. r-�C[, wM ifley intnCt and hlWb. kCI] - p11 Strip ID: 21452 _ 011u6110 SUip 1D, NA TesCW : JRI-I original tern Nrrl,rrz upon rcceipt P' Deriver (Corrcmrtcd) teinperaturc upon receipt °lo5rrli { Snap-cilp ID: h:h 3.4 0-4 oC, NA fN.' c+ M1A INA uC NA. iN.A cC — M.--shod: [ZltcmperatcreBlank 17Ctigabur Bottles 11Z C3un:i3= IR GTI CIOLTectiQ11 fMAM °C Methtxl of r.(iolant: E Wet ]::u ❑ Ice Packs ❑ D 'cp 0 tdoue — ❑ Ycs C] No ONA 1. Iftempt:lature ofany c fllerexct~ 1t 6 C`ti was Projac: Manage Vot;iied? - PM was Notified by; phbmc 1 emfil I face-tt�-Facc (Circle Ixne). d Yw No NA 4. Is the canuucrc W oacricr's paakjrk slip a l.adma Lo this form? Yca No 5, Wern P=ustod}• FnK eJu rs {J+�3inquistedlrccaivadj fo[iowccl Yes AIo! 6. Wcrc sample 1Ds Iis�ed oti tFie CL)C7 Yes 'O 17. Werc sample IDS Iisuxl ain rril mniple C000-ncrg? 0.7 YC5 fir" $. Wits WI'Wipll dater & tirno listed an the WU; © yes KU 9. Was ceflcctior. date & IilnO IISted Lark rtll-%Lmple mitainem? — , 'es Nr M. T)id,911 conraiiler labrt.] ui€orJrtation (ID, r=atle, Imp) ag= with tt,c C;OU7 J 'es No 1 ] . 1Y+xc tests to be wrka:m ad listed on the CDC? J 2. VJ d aA samples arrive in the proNer cxm Wnm fbr ean-h refit and/or ill good Lundi t iep (urLb-m-im, [ids on. ctc,)', ❑ Yes ❑ Nor 17 Yes Yes! Yes 1Na No Vj No II Was ad&LllLxL sample voierne aysilablel 14- Were AJ[ samples deceived w[tiJn V. the Iioldirig Limrt or 4F) ],ours, wbi!c;lever conlex rrst? 15. Were any samplcs containerfi Mi!94ingJ-excess circle Inc) samples NrA listed oil ('0C.? C Yes 71 No CKA 16. i'or VDA and tL K-175 sautples, 3vcru buWe3 PfUErli "pea-s;za" ('/�"ur brorn in diameter) in anv of the VOA 113.157 Yes No NA 17. Were al' DROlrnetatsluutri-2nI milples recei tit Fit a pK of <2? - yea No e NA I& Vk ffe aft cyanido samp: es rmx:ived a` a I > 12 and sl;lfide sample roocivod at a ]-r = 9? ❑-,es ❑No L,(jVA 1 ,+Nape all applitimblc N1-[yiTKN?4cyaridaJppeno 625-IM <0,5mVL) saran 1c5 :J%ee oC ❑ Yes ❑Nor ❑ N'20 em cliAlt CL 1 LSl1GR rregUeSt$ (1,ia. regl]estk dd d 1]Iltt4n36 h190,M > 4esi guarloiLs, rtc, , ,) eorrcri�tlytJrameribed frorn dte COC ijl;u lla: t:umment sectinrt in L[1vf57 Lj Yes J - N rk 21, kVas the Note num b l fisted ar, tlac contsi- label? if -ably g R Sarrlp1e PLWeJTaliolt i~?v:usc be corrpleted for oily sample(s) [nvwnctly preF;arvcd Or with 'MaEs u,) 3alnp]e(�j) NA — u^ra receiveLi in4UrrECtlj�praser,er[ar,r? were a[li�sicdaccorcirgJy n �auiple rceaiving with a1L of circle one: 1 l2SCkt, HNO3, H-C.I,' ;j0H using SR ri L Imc of l]reOCrylltl on NA If mom Than rsne pre.-,e.rvetive iS 1100dvd, pkcx:e n ote i n to comments be!OW 1�'A _ _ wemnuuivol t+rith h1lhhlcs>6 -l!It h- dirmcicr. [S) `"" _ .VCTC lv:ziVid with TRC } 0-! rkag'L(1'M 1$!!a?) and 4' lB acoord[rtgly in sample rcuciving with s4digtt] Ihiosuy3W (No, With S111�21y fD., N,t baroode labels uppl[cti by: tSw (gate- 1 1lMaU21 Cominews: Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 147 of 149 �0 <CD m D ;v v CD C 0 °� rn m o m N � r o ;_ vco 1 3 0CD V C N 0 W CD o� CD V � �C -4� V 0 O O CD y b q oo co O O V A � m ro w 0 E3 ,?Ana{yflal4 t spnp'Pr;: Sj , AdfAwi ar flakxi Na fla kka-L! ' cl.c }r&ocirti,. Pjl�-cr 'Plldl SGI7�G�R.dj�2 [Ctili'IIC�'71, GIf9i�ftil 4$ 40y]#4'sti CiiihllOJl iA9[1y Li 3! {� L i1 — _ 1 RunAMUKd rm P cQukdjPyAWiokepwvHfrL L-h*ff pfpxpAfiW see„aaAush f4m-cil�o Sale A.;s�xn.xf ,rMfBFA fo L7fblf �w Dad ]TR�r 2. RdiilgWiBrJrctaY � f UB,� Jd'i1e d R{'J',"iIOUJ_°,ked$y 5 'fey T• �hr01e: �J1 sarr-gp�� d,'& r�l�dr'.�r! �� rpur urea+cs i5Z1lT7 rA,epa:! 81S7R�FfUTlOM_ ki" rT� B L W�A91uGT Ao 2,3Lbl Vy xri r s,-Vwws�. PN.N Y3.4NC'ii2m CAP, PACE ANALYTICAL SERVICES, LLC 10: Vantage -oirit Drive • west cuur k�'a, w', n172 is ephcn9 fko, 603-791�7�� Fax Np. �U:3-�#l1-9�11 -n".pam-1 ahs .coir Number 127109 Takpl wi? M1h IP-rnaA' ' G4.nra Ma. ,�na[�sa �s��r�'rnaaspew�A99�G7J pd� .... iJ30DW 1-4 f �iefTls�s r+GoaLsr r,l�. P,waW Hazard G[t9oprpv4rj �. is v rJ'Fr4iT:15 i FarrJivkle +ill II Il f — F4 £911 I Unknnm 2. Rr r.L'Trf by 4, Lab c q�rxDy }} ff LAD USE ONLY fiereJpL°t,xme(c,r*l Yell% No icaYacR Frrerie,'', .0CPLJW:Fcfr.W�5 �.SN-v fej Hers JR)a I6l3 T!i w7 I _ _ �aaxromr JSfi,:J::Jrt:: SsEX.*J::'�+�2-J1 m D D 1 VT/ N C 0 m cn r r 0 PACE ANALYTICAL SERVICES, LLC Samples Receipt CherkJist{$RC} (MEaaI:DC-151 Ee visLwJ--9f29/2020 r<s' iy1;ci! Issiung Atlthariky: Pat- ENV - V cQk Page 1 of 1 Sample Rmelpt CheckUst (SRC) C.ieut.. CO.Qlcr Jji&pected 13Addle: KDIt A' j I lmno2l Lot g; W11017 M ai uCrc:cipt� paces Clic,d LIPS FedEx Other, -- —i J Yes I L JNQjI. Wzn7enstody 0e1fs p ucnton thr coolor7 LVJ Yos Ip Na N 2,Ifclts'ad4'sCtllar�%Cre ent,wel-eth in44utandunbrnl:on? I Slr p [ , z; sr C] krine Strip ID: NA Tested riginr W-TiperatumIWirece[pt.1-3c�'ivsd� rrY0tC3}tels,pe,Ml13M13poltire��=pt MolidSnap-i:sIp�C�: NA 3-7 f3.7 c + NAL f NA oC NA f NA cC NA t NA oC Mi�thcd; [J Tempwatl�rc Block in�i ]3� d;s IR Gun ID-. 3 IR GU-1 C-O"Cotion Factor; t' fvlet']od of enol;w; "A r 1t:C P ac.Ics Q DFy ke Q Nor e � Yr s ❑ c, ON,a, RilmneraUru oCany "Q[ar euezded U9C, was FmjMCt Manager to fioi' PM was Nwif ier! hY' P1>�to f ciftail r r:uac-#�rfaca [c[rtic Cnc). No NA _ 4, Js the oamn,erc[at cvuricr's pa:kin� �Iip Mas:Jsed 1p this farm? PYcs V YetiNo S, Were 'p c�custod' Yes Wo 6, Werr €arrpla: iDs 11s17Ndim 1k- COC? ,/ Ytis ❑#o, 7- Were sartli,le ILIs listed a-1 sill ssmp]e tont:,mcrs? ::—]S. W08coJl-ectimidwtrcdr;thnelistedoaltlleCC►C7' Ycs $. 14�iis ca:lection Maio & 1=nie listcd an aJ sample conm[ncrs? Yes Ala 10, Did all Cantrncr label irnt:6rmat[olt CID, dHir., tone) agm with rlre COC', Yes No I I . W era tests to be peu'iirnuu;d hstmd on thr. CC}C7 Yes No 12. DU all sainplen arrivc in the �ygper cantaircrs for cash test andfar in gaud rat riditio� {unh,'olteu, lt{15 on, i:'C.)? lJ Ye5 LI � Jo 13- W8s adqullt� sari le vr~lume avziiabir? Ycs No 14. Were a:] samples received within'/ �tC huldi¢L time ar 48 holes, whichever oNyles firat'� Lj Yes ! Na I5, Were &nysamplescontainers rrii ;:nglexocss �irrleone' Saiapics Not lister on C )C% Q ve No DNA 16, For VCA and KB&-175 3arrlplca, Were hlrbbles present>"pea„iF "( �"ar Groin In diameter) in any of the VOA vials? 1`es N❑ l+IA1 17-1�e�e a]I M.Wrre#aJskiwrieat Samples reccivM at a pIt 0r< Yea R'u J NA I 18. Were all cy.M,ide sarnpJesnCeCivcd at a U'� i and u,]Iida sElnplts reeei�ed at apH 97 [� 1'C5 ©NOS QNJti1 2 , W--rn a[ app![cab[e N F3 y T KNfcy{1md:Jphei7irlr —9,=?frCiR-3 (C 11.5uygfL z4 Mple% tree of Y" C] No ON—k 20, llkrac cliera rmnarWrequlGsts (I.E. requested dilutions, A451[NISD deliguatioiis, oks,,.) uorrectily, w msoribed from the WC Jnpo the cam niart>arMon in LI`viS? Q 'es ✓ Na Was the uotc rr u,o i1mr lis-ed an tilt vuiwainer labol'x Ifye—,, Qliutu # iainpk Jf'reservation GMVSL be cowpiclrd fo; any mffnple(s) incorrectly p],escrvoti orwith hcadspace.) `;arllpie(s) NA _wen r�o�ivad imott',cotly preserved and we:,c jitijusted netordingly n 5dRlr�le i BC41Yoig wlt[i N. mI, Uf circle OM. HM04, KKW, [JUIM40H usir-g SR 4 X" f s1Y-a of ^Oryntion 11AIf more tt an ore pnesel-vut:vc is uedtA please :iak- in the car_ir'icnts klaw. NA mere ruz;. ed willk b4bJes : 6 mrp in dJa imt-ur. were re"NQy Wilt ']'RC > 0.5 m[�L (lf 419 Min) an[f were ester accordingly in sample r3eivi»1 with sodium #h:osailfale ll 2%) wish Shealy ID: NA R bwcolie labels applied by: KUK►V {' mimc-lts- DM';- 1tni,7pr.i Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 149 of 149 0 aceAnalytical Report of Analysis Bunnell-Lammons Engineering, Inc. 6004 Ponders Court Greenville, SC 29615 Attention: Andy Alexander Project Name: Active Buncombe County Landfill SW Project Number: 9378-26A Lot Number:WJ30018 Date Completed:12/07/2021 12/13/2021 11:15 AM Approved and released by: Project Manager II: Lucas Odom pCC/►F� 24r�A SOA ANSI National Accreditation Board A C C R E D I T E D TESTING LABORATORY The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 1 of 58 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative Bunnell-Lammons Engineering, Inc. Lot Number: WJ30018 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved The NELAC Institute (TNI) standards, the Pace Analytical Services, LLC ("Pace") Laboratory Quality Manual, standard operating procedures (SOPS), and Pace policies. Any exceptions to the TNI standards, the Laboratory Quality Manual, SOPS or policies are qualified on the results page or discussed below. Pace is a TNI accredited laboratory; however, the following analyses are currently not listed on our TNI scope of accreditation: Biological Tissue: All, Non -Potable Water: SGT-HEM EPA 1664B, Silica EPA 200.7, Boron, Calcium, Silicon, Strontium EPA 200.8, Bicarbonate, Carbonate, and Hydroxide Alkalinity SM 2320 B-2011, Fecal Coliform SM 9221 C E-2006 & SM 9222D-2006, Strontium SW-846 6010D, VOC SM 6200 B-2011, Drinking Water: VOC (excluding BTEX, MTBE, Naphthalene, & 1,2-dichloroethane) EPA 524.2, Solid Chemical Material: TOC Walkley-Black. If you have any questions regarding this report please contact the Pace Project Manager listed on the cover page. VOCs by GUMS Due to the large number of spiked analytes, there is a high probability that one or more analytes will recover outside acceptance limits. The laboratory's SOP allows for 10% of analytes to recover marginally outside criteria. The following analytes recovered marginally outside LCS criteria: Acetone (141 %). Reanalysis of the following samples was performed outside of the analytical holding time for 2-Butanone and Vinyl Acetate due to not being detected in the LOQ: WJ30018-001, WJ30018-002, WJ30018-003, WJ30018-004, WJ30018-005, WJ30018-006. Metals by ICP-MS The method blank associated with batch 21241 yielded a "J" value detection for Zinc. No corrective action is required as this is an estimated value recovered below the LOQ. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 whw.pacelabs.com Page 2 of 58 PACE ANALYTICAL SERVICES, LLC Sample Summary Bunnell-Lammons Engineering, Inc. Lot Number: WJ30018 Sample Number Sample ID Matrix Date Sampled Date Received 001 SW-6 Aqueous 10/27/20210920 10/29/2021 002 SW-5 Aqueous 10/27/20210955 10/29/2021 003 SW-2 Aqueous 10/27/20211040 10/29/2021 004 SW-8 Aqueous 10/27/20211155 10/29/2021 005 SW-1 Aqueous 10/27/20211210 10/29/2021 006 SW-4 Aqueous 10/27/20211130 10/29/2021 007 SW-4 Aqueous 10/26/20211600 10/28/2021 008 SW-3 Aqueous 10/26/20211625 10/28/2021 (8 samples) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 3 of 58 PACE ANALYTICAL SERVICES, LLC Detection Summary Bunnell-Lammons Engineering, Inc. Lot Number: WJ30018 Sample Sample ID Matrix Parameter Method Result Q Units Page 001 SW-6 Aqueous Barium 6020B 100 ug/L 7 002 SW-5 Aqueous 1,4-Dioxane 8260D (SIM) 8.0 ug/L 9 002 SW-5 Aqueous Tetrahydrofuran 8260D 1.5 J ug/L 10 002 SW-5 Aqueous Barium 6020B 190 ug/L 10 002 SW-5 Aqueous Cobalt 6020B 12 ug/L 10 002 SW-5 Aqueous Nickel 6020B 24 ug/L 11 002 SW-5 Aqueous Zinc 6020B 8.6 J ug/L 11 003 SW-2 Aqueous Barium 6020B 53 ug/L 13 004 SW-8 Aqueous Barium 6020B 52 ug/L 16 005 SW-1 Aqueous Barium 6020B 130 ug/L 19 005 SW-1 Aqueous Chromium 6020B 1.4 J ug/L 19 005 SW-1 Aqueous Cobalt 6020B 5.9 ug/L 19 005 SW-1 Aqueous Copper 6020B 64 ug/L 19 005 SW-1 Aqueous Lead 6020B 3.3 ug/L 20 005 SW-1 Aqueous Vanadium 6020B 3.1 J ug/L 20 005 SW-1 Aqueous Zinc 6020B 44 ug/L 20 006 SW-4 Aqueous Antimony 6020B 1.7 J ug/L 22 006 SW-4 Aqueous Barium 6020B 130 ug/L 22 006 SW-4 Aqueous Chromium 6020B 7.0 ug/L 22 006 SW-4 Aqueous Cobalt 6020B 5.4 ug/L 22 006 SW-4 Aqueous Copper 6020B 5.8 ug/L 22 006 SW-4 Aqueous Lead 6020B 1.3 ug/L 23 006 SW-4 Aqueous Nickel 6020B 8.0 ug/L 23 006 SW-4 Aqueous Vanadium 6020B 11 ug/L 23 006 SW-4 Aqueous Zinc 6020B 19 ug/L 23 008 SW-3 Aqueous 1,4-Dioxane 8260D (SIM) 15 ug/L 24 008 SW-3 Aqueous Acetone 8260D 9.7 JL ug/L 24 008 SW-3 Aqueous Barium 6020B 190 ug/L 25 008 SW-3 Aqueous Chromium 6020B 2.3 J ug/L 25 008 SW-3 Aqueous Cobalt 6020B 7.7 ug/L 25 008 SW-3 Aqueous Copper 6020B 4.1 J ug/L 25 008 SW-3 Aqueous Lead 6020B 0.90 J ug/L 26 008 SW-3 Aqueous Nickel 6020B 19 ug/L 26 008 SW-3 Aqueous Zinc 6020B 13 B ug/L 26 (34 detections) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 4 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-001 Description: SW-6 Matrix: Aqueous Date Sampled:10/27/2021 0920 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/03/2021 2018 JWO 21225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 82 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0557 JWO 21878 2 5030B 8260D 1 12/03/20211241 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L 2 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 5 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-001 Description: SW-6 Matrix: Aqueous Date Sampled:10/27/2021 0920 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0557 JWO 21878 2 5030B 8260D 1 12/03/20211241 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 92 70-130 H 89 70-130 1,2-Dichloroethane-d4 103 70-130 H 124 70-130 Toluene-d8 101 70-130 H 107 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11 /02/2021 1839 BN W 11 /02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 100 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 6 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-001 Description: SW-6 Matrix: Aqueous Date Sampled:10/27/2021 0920 Date Received:10/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1839 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 7 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-002 Description: SW-5 Matrix: Aqueous Date Sampled:10/27/2021 0955 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/03/2021 2043 JWO 21225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 8.0 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 82 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0622 JWO 21878 2 5030B 8260D 1 12/03/20211306 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L 2 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 8 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-002 Description: SW-5 Matrix: Aqueous Date Sampled:10/27/2021 0955 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0622 JWO 21878 2 5030B 8260D 1 12/03/20211306 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D 1.5 J 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 90 70-130 H 84 70-130 1,2-Dichloroethane-d4 100 70-130 H 124 70-130 Toluene-d8 99 70-130 H 106 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11 /02/2021 1841 BN W 11 /02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 190 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 12 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 9 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-002 Description: SW-5 Matrix: Aqueous Date Sampled:10/27/2021 0955 Date Received:10/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1841 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Copper 7440-50-8 Lead 7439-92-1 Nickel 7440-02-0 Selenium 7782-49-2 Silver 7440-22-4 Thallium 7440-28-0 Vanadium 7440-62-2 Zinc 7440-66-6 6020B ND 5.0 1.3 ug/L 1 6020B ND 1.0 0.25 ug/L 1 6020B 24 5.0 1.3 ug/L 1 6020B ND 5.0 1.3 ug/L 1 6020B ND 1.0 0.25 ug/L 1 6020B ND 0.50 0.15 ug/L 1 6020B ND 5.0 2.5 ug/L 1 6020B 8.6 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 10 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-003 Description: SW-2 Matrix: Aqueous Date Sampled:10/27/2021 1040 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/03/2021 2107 JWO 21225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 83 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0647 JWO 21878 2 5030B 8260D 1 12/03/20211332 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L 2 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 11 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-003 Description: SW-2 Matrix: Aqueous Date Sampled:10/27/2021 1040 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0647 JWO 21878 2 5030B 8260D 1 12/03/20211332 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 91 70-130 H 85 70-130 1,2-Dichloroethane-d4 105 70-130 H 126 70-130 Toluene-d8 101 70-130 H 106 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1843 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 53 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 12 of 58 Client: Bun nell-Lammons Engineering, Inc. Laboratory ID: WJ30018-003 Description: SW-2 Matrix: Aqueous Date Sampled:10/27/2021 1040 Date Received:10/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/02/2021 1843 BNW 11/02/2021 0357 20754 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOCI = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure ND = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 13 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-004 Description: SW-8 Matrix: Aqueous Date Sampled:10/27/2021 1155 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/03/2021 2132 JWO 21225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 85 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0712 JWO 21878 2 5030B 8260D 1 12/03/20211358 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L 2 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 14 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-004 Description: SW-8 Matrix: Aqueous Date Sampled:10/27/2021 1155 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0712 JWO 21878 2 5030B 8260D 1 12/03/20211358 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Tetrahydrofuran 109-99-9 8260D ND 5.0 1.0 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 88 70-130 H 87 70-130 1,2-Dichloroethane-d4 99 70-130 H 129 70-130 Toluene-d8 99 70-130 H 105 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11 /03/2021 1806 BN W 11 /02/2021 1210 20753 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 52 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 15 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-004 Description: SW-8 Matrix: Aqueous Date Sampled:10/27/2021 1155 Date Received:10/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/03/2021 1806 BNW 11/02/2021 1210 20753 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 16 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-005 Description: SW-1 Matrix: Aqueous Date Sampled:10/27/2021 1210 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/03/2021 2156 JWO 21225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 84 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0736 JWO 21878 2 5030B 8260D 1 12/03/20211423 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L 2 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 17 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-005 Description: SW-1 Matrix: Aqueous Date Sampled:10/27/2021 1210 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0736 JWO 21878 2 5030B 8260D 1 12/03/20211423 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 91 70-130 H 89 70-130 1,2-Dichloroethane-d4 100 70-130 H 126 70-130 Toluene-d8 99 70-130 H 107 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/03/2021 1808 BNW 11/02/2021 1210 20753 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 130 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.4 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.9 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 64 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 18 of 58 Client: Bun nell-Lammons Engineering, Inc. Laboratory ID: WJ30018-005 Description: SW-1 Matrix: Aqueous Date Sampled:10/27/2021 1210 Date Received:10/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/03/2021 1808 BNW 11/02/2021 1210 20753 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Lead 7439-92-1 6020B 3.3 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.1 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 44 10 2.5 ug/L 1 LOCI = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure ND = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 19 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-006 Description: SW-4 Matrix: Aqueous Date Sampled:10/27/2021 1130 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/03/2021 2221 JWO 21225 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 89 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0802 JWO 21878 2 5030B 8260D 1 12/03/20211448 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND H 10 2.0 ug/L 2 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 20 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-006 Description: SW-4 Matrix: Aqueous Date Sampled:10/27/2021 1130 Date Received:10/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/10/2021 0802 JWO 21878 2 5030B 8260D 1 12/03/20211448 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 93 70-130 H 87 70-130 1,2-Dichloroethane-d4 102 70-130 H 126 70-130 Toluene-d8 104 70-130 H 105 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/03/2021 1814 BNW 11/02/2021 1210 20753 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 1.7 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 130 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 7.0 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.4 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.8 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 21 of 58 Client: Bun nell-Lammons Engineering, Inc. Laboratory ID: WJ30018-006 Description: SW-4 Matrix: Aqueous Date Sampled:10/27/2021 1130 Date Received:10/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/03/2021 1814 BNW 11/02/2021 1210 20753 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Lead 7439-92-1 6020B 1.3 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 8.0 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 11 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 19 10 2.5 ug/L 1 LOCI = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure ND = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 22 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-008 Description: SW-3 Matrix: Aqueous Date Sampled:10/26/2021 1625 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/08/2021 1247 CAW 21673 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 15 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 81 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/20211922 CAW 21793 2 5030B 8260D 1 12/03/20211514 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 9.7 JL 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 23 of 58 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WJ30018-008 Description: SW-3 Matrix: Aqueous Date Sampled:10/26/2021 1625 Date Received:10/28/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/09/20211922 CAW 21793 2 5030B 8260D 1 12/03/20211514 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND H 5.0 1.2 ug/L 2 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 91 70-130 H 87 70-130 1,2-Dichloroethane-d4 113 70-130 H 124 70-130 Toluene-d8 104 70-130 H 105 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1707 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 190 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.3 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 7.7 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 4.1 J 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 24 of 58 Client: Bun nell-Lammons Engineering, Inc. Laboratory ID: WJ30018-008 Description: SW-3 Matrix: Aqueous Date Sampled:10/26/2021 1625 Date Received:10/28/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1707 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Lead 7439-92-1 6020B 0.90 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 19 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 13 B 10 2.5 ug/L 1 LOCI = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure ND = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 25 of 58 QC Summary Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 26 of 58 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: WQ21225-001 Matrix: Aqueous Batch: 21225 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane ND 1 3.0 1.0 ug/L 11/04/2021 0907 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 92 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 27 of 58 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: WQ21225-002 Matrix: Aqueous Batch: 21225 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 48 1 97 70-130 11/03/2021 1758 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 102 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 28 of 58 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: WQ21673-001 Matrix: Aqueous Batch: 21673 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane ND 1 3.0 1.0 ug/L 11/08/2021 1012 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 85 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 29 of 58 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: WQ21673-002 Matrix: Aqueous Batch: 21673 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 53 1 106 70-130 11/08/2021 0907 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 92 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 30 of 58 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21793-001 Matrix: Aqueous Batch: 21793 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 11/09/2021 1038 Acrylonitrile ND 1 20 0.80 ug/L 11/09/2021 1038 Benzene ND 1 1.0 0.40 ug/L 11/09/2021 1038 Bromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 Bromodichloromethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 Bromoform ND 1 1.0 0.40 ug/L 11/09/2021 1038 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 11/09/2021 1038 2-Butanone (MEK) ND 1 10 2.0 ug/L 11/09/2021 1038 Carbon disulfide ND 1 1.0 0.40 ug/L 11/09/2021 1038 Carbon tetrachloride ND 1 1.0 0.40 ug/L 11/09/2021 1038 Chlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 1038 Chloroethane ND 1 2.0 0.40 ug/L 11/09/2021 1038 Chloroform ND 1 1.0 0.40 ug/L 11/09/2021 1038 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 11/09/2021 1038 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 11/09/2021 1038 Dibromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 11/09/2021 1038 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 11/09/2021 1038 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 11/09/2021 1038 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 1038 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 1038 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 1038 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 1038 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 1038 Ethylbenzene ND 1 1.0 0.40 ug/L 11/09/2021 1038 2-Hexanone ND 1 10 2.0 ug/L 11/09/2021 1038 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 11/09/2021 1038 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 11/09/2021 1038 Methylene chloride ND 1 1.0 0.40 ug/L 11/09/2021 1038 Styrene ND 1 1.0 0.41 ug/L 11/09/2021 1038 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 Tetrachloroethene ND 1 1.0 0.40 ug/L 11/09/2021 1038 Toluene ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 Trichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 1038 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 11/09/2021 1038 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 1038 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 31 of 58 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21793-001 Matrix: Aqueous Batch: 21793 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl chloride ND 1 1.0 0.40 ug/L 11/09/2021 1038 Xylenes (total) ND 1 1.0 0.40 ug/L 11/09/2021 1038 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 112 70-130 Toluene-d8 102 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 32 of 58 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21793-002 Matrix: Aqueous Batch: 21793 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 140 N 1 141 60-140 11/09/2021 0935 Acrylonitrile 100 120 1 119 70-130 11/09/2021 0935 Benzene 50 55 1 110 70-130 11/09/2021 0935 Bromochloromethane 50 53 1 107 70-130 11/09/2021 0935 Bromodichloromethane 50 55 1 109 70-130 11/09/2021 0935 Bromoform 50 53 1 107 70-130 11/09/2021 0935 Bromomethane (Methyl bromide) 50 49 1 98 70-130 11/09/2021 0935 2-Butanone (MEK) 100 120 1 116 70-130 11/09/2021 0935 Carbon disulfide 50 58 1 115 70-130 11/09/2021 0935 Carbon tetrachloride 50 53 1 106 70-130 11/09/2021 0935 Chlorobenzene 50 52 1 104 70-130 11/09/2021 0935 Chloroethane 50 57 1 114 70-130 11/09/2021 0935 Chloroform 50 53 1 106 70-130 11/09/2021 0935 Chloromethane (Methyl chloride) 50 57 1 113 60-140 11/09/2021 0935 1,2-Dibromo-3-chloropropane (DBCP) 50 56 1 111 70-130 11/09/2021 0935 Dibromochloromethane 50 53 1 107 70-130 11/09/2021 0935 1,2-Dibromoethane (EDB) 50 52 1 104 70-130 11/09/2021 0935 Dibromomethane (Methylene bromide) 50 56 1 112 70-130 11/09/2021 0935 trans- 1,4-Dichloro-2-butene 50 56 1 112 70-130 11/09/2021 0935 1,2-Dichlorobenzene 50 52 1 104 70-130 11/09/2021 0935 1,4-Dichlorobenzene 50 50 1 99 70-130 11/09/2021 0935 1,1-Dichloroethane 50 54 1 109 70-130 11/09/2021 0935 1,2-Dichloroethane 50 55 1 110 70-130 11/09/2021 0935 1,1-Dichloroethene 50 56 1 112 70-130 11/09/2021 0935 cis- 1,2-Dichloroethene 50 53 1 107 70-130 11/09/2021 0935 trans- 1,2-Dichloroethene 50 56 1 111 70-130 11/09/2021 0935 1,2-Dichloropropane 50 55 1 109 70-130 11/09/2021 0935 cis- 1,3-Dichloropropene 50 54 1 107 70-130 11/09/2021 0935 trans- 1,3-Dichloropropene 50 54 1 109 70-130 11/09/2021 0935 Ethylbenzene 50 54 1 108 70-130 11/09/2021 0935 2-Hexanone 100 120 1 125 70-130 11/09/2021 0935 Methyl iodide (lodomethane) 50 53 1 106 70-130 11/09/2021 0935 4-Methyl-2-pentanone 100 120 1 119 70-130 11/09/2021 0935 Methylene chloride 50 54 1 108 70-130 11/09/2021 0935 Styrene 50 58 1 115 70-130 11/09/2021 0935 1,1,1,2-Tetrachloroethane 50 55 1 109 70-130 11/09/2021 0935 1,1,2,2-Tetrachloroethane 50 55 1 109 70-130 11/09/2021 0935 Tetrachloroethene 50 51 1 102 70-130 11/09/2021 0935 Toluene 50 55 1 110 70-130 11/09/2021 0935 1,1,1-Trichloroethane 50 53 1 106 70-130 11/09/2021 0935 1,1,2-Trichloroethane 50 53 1 106 70-130 11/09/2021 0935 Trichloroethene 50 49 1 98 70-130 11/09/2021 0935 Trichlorofluoromethane 50 53 1 105 70-130 11/09/2021 0935 1,2,3-Trichloropropane 50 53 1 106 70-130 11/09/2021 0935 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 33 of 58 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21793-002 Matrix: Aqueous Batch: 21793 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl chloride 50 52 1 103 70-130 11/09/2021 0935 Xylenes (total) 100 110 1 111 70-130 11/09/2021 0935 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 103 70-130 1,2-Dichloroethane-d4 109 70-130 Toluene-d8 103 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 34 of 58 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21878-001 Matrix: Aqueous Batch: 21878 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 11/09/2021 2245 Acrylonitrile ND 1 20 0.80 ug/L 11/09/2021 2245 Benzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromodichloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromoform ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 11/09/2021 2245 Carbon disulfide ND 1 1.0 0.40 ug/L 11/09/2021 2245 Carbon tetrachloride ND 1 1.0 0.40 ug/L 11/09/2021 2245 Chlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Chloroethane ND 1 2.0 0.40 ug/L 11/09/2021 2245 Chloroform ND 1 1.0 0.40 ug/L 11/09/2021 2245 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 11/09/2021 2245 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 11/09/2021 2245 Dibromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 11/09/2021 2245 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 11/09/2021 2245 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 11/09/2021 2245 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 2245 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 2245 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Ethylbenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 2-Hexanone ND 1 10 2.0 ug/L 11/09/2021 2245 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 11/09/2021 2245 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 11/09/2021 2245 Methylene chloride ND 1 1.0 0.40 ug/L 11/09/2021 2245 Styrene ND 1 1.0 0.41 ug/L 11/09/2021 2245 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Tetrachloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Toluene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Trichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Vinyl chloride ND 1 1.0 0.40 ug/L 11/09/2021 2245 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 35 of 58 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21878-001 Matrix: Aqueous Batch: 21878 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Xylenes (total) ND 1 1.0 0.40 ug/L 11/09/2021 2245 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 90 70-130 1,2-Dichloroethane-d4 97 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 36 of 58 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21878-002 Matrix: Aqueous Batch: 21878 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 78 1 78 60-140 11/09/2021 2141 Acrylonitrile 100 86 1 86 70-130 11/09/2021 2141 Benzene 50 46 1 93 70-130 11/09/2021 2141 Bromochloromethane 50 45 1 90 70-130 11/09/2021 2141 Bromodichloromethane 50 49 1 97 70-130 11/09/2021 2141 Bromoform 50 54 1 109 70-130 11/09/2021 2141 Bromomethane (Methyl bromide) 50 43 1 87 70-130 11/09/2021 2141 Carbon disulfide 50 50 1 99 70-130 11/09/2021 2141 Carbon tetrachloride 50 47 1 95 70-130 11/09/2021 2141 Chlorobenzene 50 48 1 97 70-130 11/09/2021 2141 Chloroethane 50 42 1 84 70-130 11/09/2021 2141 Chloroform 50 43 1 86 70-130 11/09/2021 2141 Chloromethane (Methyl chloride) 50 38 1 76 60-140 11/09/2021 2141 1,2-Dibromo-3-chloropropane (DBCP) 50 47 1 94 70-130 11/09/2021 2141 Dibromochloromethane 50 51 1 102 70-130 11/09/2021 2141 1,2-Dibromoethane (EDB) 50 50 1 100 70-130 11/09/2021 2141 Dibromomethane (Methylene bromide) 50 46 1 93 70-130 11/09/2021 2141 trans- 1,4-Dichloro-2-butene 50 46 1 91 70-130 11/09/2021 2141 1,2-Dichlorobenzene 50 48 1 96 70-130 11/09/2021 2141 1,4-Dichlorobenzene 50 45 1 90 70-130 11/09/2021 2141 1,1-Dichloroethane 50 43 1 86 70-130 11/09/2021 2141 1,2-Dichloroethane 50 45 1 90 70-130 11/09/2021 2141 1,1-Dichloroethene 50 47 1 93 70-130 11/09/2021 2141 cis- 1,2-Dichloroethene 50 43 1 87 70-130 11/09/2021 2141 trans- 1,2-Dichloroethene 50 43 1 87 70-130 11/09/2021 2141 1,2-Dichloropropane 50 49 1 98 70-130 11/09/2021 2141 cis- 1,3-Dichloropropene 50 54 1 108 70-130 11/09/2021 2141 trans- 1,3-Dichloropropene 50 48 1 96 70-130 11/09/2021 2141 Ethylbenzene 50 49 1 98 70-130 11/09/2021 2141 2-Hexanone 100 100 1 103 70-130 11/09/2021 2141 Methyl iodide (lodomethane) 50 50 1 100 70-130 11/09/2021 2141 4-Methyl-2-pentanone 100 110 1 106 70-130 11/09/2021 2141 Methylene chloride 50 49 1 98 70-130 11/09/2021 2141 Styrene 50 53 1 107 70-130 11/09/2021 2141 1,1,1,2-Tetrachloroethane 50 50 1 99 70-130 11/09/2021 2141 1,1,2,2-Tetrachloroethane 50 45 1 90 70-130 11/09/2021 2141 Tetrachloroethene 50 48 1 96 70-130 11/09/2021 2141 Toluene 50 48 1 96 70-130 11/09/2021 2141 1,1,1-Trichloroethane 50 47 1 95 70-130 11/09/2021 2141 1,1,2-Trichloroethane 50 48 1 95 70-130 11/09/2021 2141 Trichloroethene 50 46 1 91 70-130 11/09/2021 2141 Trichlorofluoromethane 50 49 1 97 70-130 11/09/2021 2141 1,2,3-Trichloropropane 50 46 1 93 70-130 11/09/2021 2141 Vinyl chloride 50 40 1 80 70-130 11/09/2021 2141 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 37 of 58 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21878-002 Matrix: Aqueous Batch: 21878 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Xylenes (total) 100 100 1 102 70-130 11/09/2021 2141 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 91 70-130 1,2-Dichloroethane-d4 86 70-130 Toluene-d8 91 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 38 of 58 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21878-001 Matrix: Aqueous Batch: 21878 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 11/09/2021 2245 Acrylonitrile ND 1 20 0.80 ug/L 11/09/2021 2245 Benzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromodichloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromoform ND 1 1.0 0.40 ug/L 11/09/2021 2245 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 11/09/2021 2245 Carbon disulfide ND 1 1.0 0.40 ug/L 11/09/2021 2245 Carbon tetrachloride ND 1 1.0 0.40 ug/L 11/09/2021 2245 Chlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Chloroethane ND 1 2.0 0.40 ug/L 11/09/2021 2245 Chloroform ND 1 1.0 0.40 ug/L 11/09/2021 2245 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 11/09/2021 2245 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 11/09/2021 2245 Dibromochloromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 11/09/2021 2245 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 11/09/2021 2245 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 11/09/2021 2245 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 2245 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 2245 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Ethylbenzene ND 1 1.0 0.40 ug/L 11/09/2021 2245 2-Hexanone ND 1 10 2.0 ug/L 11/09/2021 2245 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 11/09/2021 2245 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 11/09/2021 2245 Methylene chloride ND 1 1.0 0.40 ug/L 11/09/2021 2245 Styrene ND 1 1.0 0.41 ug/L 11/09/2021 2245 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Tetrachloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Tetrahydrofuran ND 1 5.0 1.0 ug/L 11/09/2021 2245 Toluene ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 Trichloroethene ND 1 1.0 0.40 ug/L 11/09/2021 2245 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 11/09/2021 2245 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 11/09/2021 2245 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 39 of 58 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ21878-001 Matrix: Aqueous Batch: 21878 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl chloride ND 1 1.0 0.40 ug/L 11/09/2021 2245 Xylenes (total) ND 1 1.0 0.40 ug/L 11/09/2021 2245 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 90 70-130 1,2-Dichloroethane-d4 97 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 40 of 58 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21878-002 Matrix: Aqueous Batch: 21878 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 78 1 78 60-140 11/09/2021 2141 Acrylonitrile 100 86 1 86 70-130 11/09/2021 2141 Benzene 50 46 1 93 70-130 11/09/2021 2141 Bromochloromethane 50 45 1 90 70-130 11/09/2021 2141 Bromodichloromethane 50 49 1 97 70-130 11/09/2021 2141 Bromoform 50 54 1 109 70-130 11/09/2021 2141 Bromomethane (Methyl bromide) 50 43 1 87 70-130 11/09/2021 2141 Carbon disulfide 50 50 1 99 70-130 11/09/2021 2141 Carbon tetrachloride 50 47 1 95 70-130 11/09/2021 2141 Chlorobenzene 50 48 1 97 70-130 11/09/2021 2141 Chloroethane 50 42 1 84 70-130 11/09/2021 2141 Chloroform 50 43 1 86 70-130 11/09/2021 2141 Chloromethane (Methyl chloride) 50 38 1 76 60-140 11/09/2021 2141 1,2-Dibromo-3-chloropropane (DBCP) 50 47 1 94 70-130 11/09/2021 2141 Dibromochloromethane 50 51 1 102 70-130 11/09/2021 2141 1,2-Dibromoethane (EDB) 50 50 1 100 70-130 11/09/2021 2141 Dibromomethane (Methylene bromide) 50 46 1 93 70-130 11/09/2021 2141 trans- 1,4-Dichloro-2-butene 50 46 1 91 70-130 11/09/2021 2141 1,2-Dichlorobenzene 50 48 1 96 70-130 11/09/2021 2141 1,4-Dichlorobenzene 50 45 1 90 70-130 11/09/2021 2141 1,1-Dichloroethane 50 43 1 86 70-130 11/09/2021 2141 1,2-Dichloroethane 50 45 1 90 70-130 11/09/2021 2141 1,1-Dichloroethene 50 47 1 93 70-130 11/09/2021 2141 cis- 1,2-Dichloroethene 50 43 1 87 70-130 11/09/2021 2141 trans- 1,2-Dichloroethene 50 43 1 87 70-130 11/09/2021 2141 1,2-Dichloropropane 50 49 1 98 70-130 11/09/2021 2141 cis- 1,3-Dichloropropene 50 54 1 108 70-130 11/09/2021 2141 trans- 1,3-Dichloropropene 50 48 1 96 70-130 11/09/2021 2141 Ethylbenzene 50 49 1 98 70-130 11/09/2021 2141 2-Hexanone 100 100 1 103 70-130 11/09/2021 2141 Methyl iodide (lodomethane) 50 50 1 100 70-130 11/09/2021 2141 4-Methyl-2-pentanone 100 110 1 106 70-130 11/09/2021 2141 Methylene chloride 50 49 1 98 70-130 11/09/2021 2141 Styrene 50 53 1 107 70-130 11/09/2021 2141 1,1,1,2-Tetrachloroethane 50 50 1 99 70-130 11/09/2021 2141 1,1,2,2-Tetrachloroethane 50 45 1 90 70-130 11/09/2021 2141 Tetrachloroethene 50 48 1 96 70-130 11/09/2021 2141 Tetrahydrofuran 50 44 1 88 70-130 11/09/2021 2141 Toluene 50 48 1 96 70-130 11/09/2021 2141 1,1,1-Trichloroethane 50 47 1 95 70-130 11/09/2021 2141 1,1,2-Trichloroethane 50 48 1 95 70-130 11/09/2021 2141 Trichloroethene 50 46 1 91 70-130 11/09/2021 2141 Trichlorofluoromethane 50 49 1 97 70-130 11/09/2021 2141 1,2,3-Trichloropropane 50 46 1 93 70-130 11/09/2021 2141 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 41 of 58 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ21878-002 Matrix: Aqueous Batch: 21878 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl chloride 50 40 1 80 70-130 11/09/2021 2141 Xylenes (total) 100 100 1 102 70-130 11/09/2021 2141 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 91 70-130 1,2-Dichloroethane-d4 86 70-130 Toluene-d8 91 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 42 of 58 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ24540-001 Matrix: Aqueous Batch: 24540 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 2-Butanone (MEK) ND 1 10 2.0 ug/L 12/03/2021 1027 Vinyl acetate ND 1 5.0 1.2 ug/L 12/03/2021 1027 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 123 70-130 Toluene-d8 107 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 43 of 58 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ24540-002 Matrix: Aqueous Batch: 24540 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 2-Butanone (MEK) 100 120 1 119 70-130 12/03/2021 0923 Vinyl acetate 50 53 1 105 60-140 12/03/2021 0923 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 99 70-130 1,2-Dichloroethane-d4 102 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 44 of 58 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ24540-001 Matrix: Aqueous Batch: 24540 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 2-Butanone (MEK) ND 1 10 2.0 ug/L 12/03/2021 1027 Vinyl acetate ND 1 5.0 1.2 ug/L 12/03/2021 1027 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 123 70-130 Toluene-d8 107 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 45 of 58 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ24540-002 Matrix: Aqueous Batch: 24540 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 2-Butanone (MEK) 100 120 1 119 70-130 12/03/2021 0923 Vinyl acetate 50 53 1 105 60-140 12/03/2021 0923 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 99 70-130 1,2-Dichloroethane-d4 102 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 46 of 58 ICP-MS Metals - MB Sample ID: WQ20753-001 Matrix: Aqueous Batch: 20753 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/02/2021 1210 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 11/03/2021 1721 Arsenic ND 1 2.0 1.3 ug/L 11/03/2021 1721 Barium ND 1 5.0 1.3 ug/L 11/03/2021 1721 Beryllium ND 1 0.40 0.15 ug/L 11/03/2021 1721 Cadmium ND 1 0.50 0.13 ug/L 11/03/2021 1721 Chromium ND 1 5.0 1.3 ug/L 11/03/2021 1721 Cobalt ND 1 5.0 1.3 ug/L 11/03/2021 1721 Copper ND 1 5.0 1.3 ug/L 11/03/2021 1721 Lead ND 1 1.0 0.25 ug/L 11/03/2021 1721 Nickel ND 1 5.0 1.3 ug/L 11/03/2021 1721 Selenium ND 1 5.0 1.3 ug/L 11/03/2021 1721 Silver ND 1 1.0 0.25 ug/L 11/03/2021 1721 Thallium ND 1 0.50 0.15 ug/L 11/03/2021 1721 Vanadium ND 1 5.0 2.5 ug/L 11/03/2021 1721 Zinc ND 1 10 2.5 ug/L 11/03/2021 1721 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 47 of 58 ICP-MS Metals - LCS Sample ID: WQ20753-002 Matrix: Aqueous Batch: 20753 Prep Method: 3OO5A Analytical Method: 6020B Prep Date: 11/02/2021 1210 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 92 1 92 80-120 11/03/2021 1723 Arsenic 100 99 1 99 80-120 11/03/2021 1723 Barium 100 94 1 94 80-120 11/03/2021 1723 Beryllium 100 97 1 97 80-120 11/03/2021 1723 Cadmium 100 95 1 95 80-120 11/03/2021 1723 Chromium 100 99 1 99 80-120 11/03/2021 1723 Cobalt 100 98 1 98 80-120 11/03/2021 1723 Copper 100 100 1 105 80-120 11/03/2021 1723 Lead 100 94 1 94 80-120 11/03/2021 1723 Nickel 100 100 1 101 80-120 11/03/2021 1723 Selenium 100 96 1 96 80-120 11/03/2021 1723 Silver 100 90 1 90 80-120 11/03/2021 1723 Thallium 100 91 1 91 80-120 11/03/2021 1723 Vanadium 100 96 1 96 80-120 11/03/2021 1723 Zinc 100 98 1 98 80-120 11/03/2021 1723 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 48 of 58 ICP-MS Metals - MB Sample ID: WQ20754-001 Matrix: Aqueous Batch: 20754 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/02/2021 0357 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 11/02/2021 1749 Arsenic ND 1 2.0 1.3 ug/L 11/02/2021 1749 Barium ND 1 5.0 1.3 ug/L 11/02/2021 1749 Beryllium ND 1 0.40 0.15 ug/L 11/02/2021 1749 Cadmium ND 1 0.50 0.13 ug/L 11/02/2021 1749 Chromium ND 1 5.0 1.3 ug/L 11/02/2021 1749 Cobalt ND 1 5.0 1.3 ug/L 11/02/2021 1749 Copper ND 1 5.0 1.3 ug/L 11/02/2021 1749 Lead ND 1 1.0 0.25 ug/L 11/02/2021 1749 Nickel ND 1 5.0 1.3 ug/L 11/02/2021 1749 Selenium ND 1 5.0 1.3 ug/L 11/02/2021 1749 Silver ND 1 1.0 0.25 ug/L 11/02/2021 1749 Thallium ND 1 0.50 0.15 ug/L 11/02/2021 1749 Vanadium ND 1 5.0 2.5 ug/L 11/02/2021 1749 Zinc ND 1 10 2.5 ug/L 11/02/2021 1749 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 49 of 58 ICP-MS Metals - LCS Sample ID: WQ20754-002 Matrix: Aqueous Batch: 20754 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/02/2021 0357 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 98 1 98 80-120 11/02/2021 1751 Arsenic 100 100 1 102 80-120 11/02/2021 1751 Barium 100 97 1 97 80-120 11/02/2021 1751 Beryllium 100 99 1 99 80-120 11/02/2021 1751 Cadmium 100 100 1 101 80-120 11/02/2021 1751 Chromium 100 100 1 104 80-120 11/02/2021 1751 Cobalt 100 100 1 101 80-120 11/02/2021 1751 Copper 100 110 1 107 80-120 11/02/2021 1751 Lead 100 100 1 101 80-120 11/02/2021 1751 Nickel 100 110 1 105 80-120 11/02/2021 1751 Selenium 100 100 1 104 80-120 11/02/2021 1751 Silver 100 96 1 96 80-120 11/02/2021 1751 Thallium 100 96 1 96 80-120 11/02/2021 1751 Vanadium 100 100 1 102 80-120 11/02/2021 1751 Zinc 100 100 1 103 80-120 11/02/2021 1751 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 50 of 58 ICP-MS Metals - MB Sample ID: WQ21241-001 Matrix: Aqueous Batch: 21241 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/07/2021 0954 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 11/08/2021 1659 Arsenic ND 1 2.0 1.3 ug/L 11/08/2021 1659 Barium ND 1 5.0 1.3 ug/L 11/08/2021 1659 Beryllium ND 1 0.40 0.15 ug/L 11/08/2021 1659 Cadmium ND 1 0.50 0.13 ug/L 11/08/2021 1659 Chromium ND 1 5.0 1.3 ug/L 11/08/2021 1659 Cobalt ND 1 5.0 1.3 ug/L 11/08/2021 1659 Copper ND 1 5.0 1.3 ug/L 11/08/2021 1659 Lead ND 1 1.0 0.25 ug/L 11/08/2021 1659 Nickel ND 1 5.0 1.3 ug/L 11/08/2021 1659 Selenium ND 1 5.0 1.3 ug/L 11/08/2021 1659 Silver ND 1 1.0 0.25 ug/L 11/08/2021 1659 Thallium ND 1 0.50 0.15 ug/L 11/08/2021 1659 Vanadium ND 1 5.0 2.5 ug/L 11/08/2021 1659 Zinc 3.2 J 1 10 2.5 ug/L 11/08/2021 1659 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 51 of 58 ICP-MS Metals - LCS Sample ID: WQ21241-002 Matrix: Aqueous Batch: 21241 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/07/2021 0954 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 97 1 97 80-120 11/08/2021 1701 Arsenic 100 99 1 99 80-120 11/08/2021 1701 Barium 100 93 1 93 80-120 11/08/2021 1701 Beryllium 100 110 1 105 80-120 11/08/2021 1701 Cadmium 100 100 1 100 80-120 11/08/2021 1701 Chromium 100 100 1 101 80-120 11/08/2021 1701 Cobalt 100 99 1 99 80-120 11/08/2021 1701 Copper 100 110 1 106 80-120 11/08/2021 1701 Lead 100 95 1 95 80-120 11/08/2021 1701 Nickel 100 100 1 103 80-120 11/08/2021 1701 Selenium 100 97 1 97 80-120 11/08/2021 1701 Silver 100 97 1 97 80-120 11/08/2021 1701 Thallium 100 93 1 93 80-120 11/08/2021 1701 Vanadium 100 100 1 101 80-120 11/08/2021 1701 Zinc 100 100 1 102 80-120 11/08/2021 1701 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 52 of 58 Chain of Custody and Miscellaneous Documents Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 53 of 58 �0 < fo m D vv CD C - v nn °rn m v� o m N � r co n 0 o O C Q K vCD n d ro (O � V <, N 0 7 W NO V � coCj) t CD CDz V CD N fo w E3 a eAnalyticaf" PACE ANALY77CAL SEFMICrzLL f06 Vaalage Poigt Ddvo - v4csl uUlumbia, SC �9f72 Toleltone Na_ 8C&791-97no Fax NO, �[ i-791-g11 kvWVj_Pacelabsxnm CMeub' - — — - . a':o'G*�nasca - �?h` --57afe Pip f~16'a@ Prefecr �, r , ..tProrwrPAL . &MM lP f D&&c:fVito �tldip-fiir Lvgg�,ti �'� fRgV,i4 gblAltrr[�d{�f �31 a.51Y,� Y Jere��inr� lLra } F almol1"S (� 'rG1�A3f �i nna� de i7R�i�.r% ly �i'v 5'PI7 {.3a5ti rf4r� iX'b V 8TO �; - �,, `. C1 �41tit b,j - GY. k Ah W.J 0017 LJO x x J 00 1 8 LL rfrnaroENWTfirLlRITl'red;Ff;cry% arrspl,ryrdoramr�l7►dAIiCJ wr�r,�,n.�a�as�' Poza s�f�rrarc.derdLFf�o¢v, sfarc'anu rrtnea eei ocrnxrsriti(;rya 7f IFreh,m2aCRer,J — traerb �.�p hl07-1gglid Flenm�a'a :.. Skj;IfrilanL : IP*nri L'. rJ410mn 7FdaW:3.j . y .�77iM T r.e Y, + 4 — - v AA_ yap+ TVW 2. Ret�eJSWJDy +?afe 7. Re1hrt�J+ e:by aafG k** a. RPPAeo'bv -- — ON: 4Fie7��geaiyhsr�by � J 4.-t `�fyrp�l+9dby -••— �F f 10f ; A!F Seri qo s a ret&r.�ad FUr �uur are,gkfi ii�ri� .n C'p,� F { r L err U,-crtxL iN7less o1F1�r arrange en;s gro rrrade.—rc�f�kl_ 'r !ra ics Pr. [ F,ec pf F S tht RAStM M VL14)�$ YELLUDLP4tfffm PPkrl5Wa xy %vdi pS�qj. f''N6Y• gim+i`7iiEri� C.r�7y n719 - Thw L�G�:J�r&ixrf.4rrib�r: �'�UO �0 <CD �> ;v v CD v v ° rn m s CD � r m n 0 o O c O— m CD n d �M V <, N 0 7 W NO co t CD C� V 0 o CD b -n w v tro x v o v� w O v M 0 00 E3 ,6(1*7 � PAGE ANALYTICAL SERVICES, LLC i Analytioaf106 VsilraUv �39iral Drive • WQSt Qalumblaj 9 ?9112 Talaphnno Net . snq-791-07OD Fa*, NG. W3-791-911 1 wLgw. mlab&cGm — Grr�J79 rkPOI! aw aw Jnxd — }�1rdrL'KS No-'rrynm �u $�' J}drLflk� QYy Jura 2do Cede i X - -- Kct2Yl lid. Pa No. ar GLM%rrMra � LY Fw_x3weLe Y�c SMT �� I �J6si/ i�011 LY.SS��V.LR -- 5'an4�n ' u h �Oi7t'min EfVx Ee'n7 �R'�L7Pi j'befAJAC ed dl. end Sw.) F+ #9J ("OrX) Go - r%njhj -ICE 1-1--,i, I ;Ittr, � ry I i i f IN la�+s�x'ie.�aa ,va J ��noJ 69AoY�JAsfrFOrdJ3rX iE 7CtGL': I w H191M v�®E for. 0% Wj3ODi7 Y I V :JO rwri Arawwd -ime AL-qdrad Pvf RM 17PMDL.H FtVMW"F 7'r9Whkd TAT) S-7MAb RY. AJ %Saale J,az .-Xf kfadam4f a. aCFi� ;brw; {•s4 r; $(4:r , Rua* itosvjfy) A-Ay*-+r- y Le -.� 2Jon-HpzaW r-. Awnble &1n Ir: za -. Palvui: Un4r.orm ', fia'A��u�eJ;o�[.b _ � i f M1-- r �76►JC T. Ji16.1e,'rtiJiy � rare runt ~. PEdo-Awe,hwby-` ! l^' Gzf �11 )k T@w 11) o 1 2.Raca,vwDy ri2la Jame -- 7l l?elu rns 5etr bJ' f]a�e TV" I RGCwed d?y i73,tis J rJ:o Ub..- - -- o Nxig, Aft sarpp 5!s we rerarrr-ed for PLrr nwPs (m r receof U+a USE O v� -- � f q�r� T.4r p R*k - r ura1J==GOQf7Efc?frAr�g ?7G'FJ�$aJY3.r7{ir1C. Try Ra[dva7ariGc,`Cir ",!a 1ceJ-g* Fk"*rT&iv 'i_-'f !h '77Fir8f�F+' M1': r'�'f+TT-c ci Yet_ ii+,�7a,ium rP l 'eA�}' F4715'� b'df'�,hb(51� F'M:Nr-r:it110[' 1'trH 1',ery�y fk-AMP .W km -. Wl0 kW-0` PACE ANALYTICAL SERVICES, LLC Sarnpi s Receipt ChcdJ list (SRC) (MEO018C-15) rtev1Sed..129f ? mo I Sall'" suing Authurlty: Pace ENV - WCOL Page 1 of 1 I le Receipt Cheeklisi (SRC) Cool ]rmpLacheri byjdata; JR472 111r371202,1 Lotiv: u'r3�tt,17rWJ3001R h1�riS 6f reCcipl: I'Aif. CJiellr iJl'S ,� HCdL•x �lllee; 'ts N0 1_ %VU7e custOdy se s rCSatrk on the r.0olerF — ' No Nil 1, Ifcu= scalp tree resent, wea+e to intact art unbtolcc,'? pA Strip ID: xt432 Chinfiac [rip JD: NA I'�sted Jk4 � t ri.Vml temparawiv srpon recoipt � Derived ( 't otmlcd) 1eMj1t'u•at1w8 Upon mcaipr 'f3Soiid Snap-C',113 ID: NA S r 4.$ ic [IA ; NA off+ NA 1 RA or ,A HA c Method: ❑1'cnlperttlurc Blank �4 ait,sl B Method Oil-voolariv 0 0 les FIR Oun ID: 5 !JR {sun Crnrectiaa Factor-o ' Wet Ice Ice Paltks 0 Pryi Ice None Y 4 No NA 3 _ if terr perslrJrc ur any ooale=' ta= cried 6,0"C, �vX J'rojcct hrtan8jer tNai- JJed? FM was Notified by,: phone + email) t:face (eiraJc anc). `t`C5 I in NA 4_ Is tht conimtrai�; COaricr'y pwkiwg slip aLERAcd to this farm? e YES No Were pmper eusbody procet[ures (i+eli»yt�ishedlrocoivcdj fol fmved? d ti'4s Teo. Vi'e� a samL,Je ID listed on Chic CC7? Yes No 7. 1Yere Sample PD IiStud on WI salr.ple c:cq Fl ner�,? YCE No $- ',Vas COflCV. 091 Q lc & titne listed ar, the C O C? V Yes J`]a 9, Was c,ill eetion d & -Irr¢ listed ott 1111 atrtiple PoWainrr�r`7 Yes AJo 10. Laid a,l] contain lat�l itifurmaiinn (LD, date, tim�j agree uilil i}te {:C][;? d YesN, II. rr; teals ,+be 'erfprmed Iisled oailhe �? Yes L_tNo ]2- Did nil samples (unbnohmi. fidx on. dtc.)? ve in d,e proR7r contahim fQ' ctuh Leg[ ande'or in ¢rood conditicn, Z Ydi Nt~ J3, VrF+a i adequate sa nre wol�me available? yes N_i 14_ A'ci-C all ri,rrpJe nC lvod wiuh,in 'r the haldina: lime or 4$ hum. wties first" Ycs f*o 1 . V4'ere AFT satttpl s cantainc1suf45ingr'excess (cirrlc one) sa7rlpleslNoi li5kodon CQC? �] Yea ]sir NA 1 ,For 'pA and R J -l?S rumple were bubhles present>"pa�,iM" (V4"vT 6ru>,rte in dia�na r) in My of OW VOA v �ls? �+e 'No NA 17_ %Vcx" all DRO/wu lals'rltttrient samples racCiYe[l a4 a PI-[ raf < 2? Yes No NA ] S. 'Wma a] I Cyanide samples rK4jvc1d at a pH > 12 a;ud sul tide sampIrs received aL a r P > 9? Yes i+fC Q]V l 19_ Wire a appltca le p# 'I'l hdlcyantda'pJxno]lfr i,>? g,3 (-, 0 5mg+L sarr,plcg Fie a � residual chlorinc7 � @S ❑NO Op'-A-0' ei'GiJicntreniii£Sfrequcsis0-e.rC4ltesteddifl.LdGn.5,?VfSurl4I T)&nigrunjorm,$tt,,,,I GOrreCtlj' iTagseribed ir, ,athe UOC irid lo ,c comment section in WM9? 'es l0 2l. Woe Clio toriu bar lkt-d o,i l w ciantainca, Sabel? if e 0iirate antplC ]Preservation (Must lee a etea fie9a:iy 5nmpJe(s) incorrectly pres?urvud or with headspam', SatnpJe(sl in :pro receiving yyN ML Ofcirele Ott _vim-e received illwwectly pt-esertired and were adimied socardingly . H2SO4, I'1NG3, ICI, ]�H014 using SR 1' ime oFpr e, �u n +t _. Jf MOM JM11 oue prnSeivati" is needed, pleays rote in the co:tunenes hrlow- Sumple#s) -NA _werercceiv d witd_ i13hbles>6 mm in diaeielw, ample r} r:.{ adjusit l aeonrdittgl J1i rumple rzoniv-.g With 3 kf@CC rcreived v,'itl i TR C > 0-5 ,np/L (] F * 19 is rro) aHd wore iut'r1 tlti'_aau]Fntc ('1i'25203) wa(h -SIMl r ID- NA SIB banccde labe's applied hy_ 'JQ1 Dat,; 1WW2021 amrnants; Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 56 of 58 �0 <CD �> vv CD C 0 0 C m v� o m N �r m n o ° c 3 m fn 0 d m -4 <, N 0 � m O° V � co U) CD CD V 0 CD N N N Q E3 d0kialyr a! , PACE ANALYTICAL SERVICES, LLC 106 Vanle�e Pain- Nve • '.Nei i Cc:lumbia, Sr— 29172 Tei9ghonq No- 801-781-970a Fax hto_ B02- '91-�g111 vrmw.pacelabs.com Number -1-2-1406 G'ror� RZTG,a 0 Lbalxf T"CJ&wv Np.I$m',:r C]h7re M1b_ naffrea� Sarrtn+�rltsy n,m .1rneYys�?nr�x,`ra�'nrnaaT,�'+'isrraL�aaol; ��.. x1M Frx[fa[i'No. pO..Vc. .Lf�d'ir SIFIiP<6�railwiFY9 I'.""+fF ° dlAre U7I�7esCrVd!+ ? Go.. IKaCLav7Mv 4 � ; a � ISe � � zr fe'umr rsr,93MQa poK-.V"Qvrtrwdm mew) 41 VWJ30018 j Yl JX' 6 i i E X s } l I& } ; 7 Ix 3 yip} ii�5} r I rlffn A"Urad 7-" R4 ":rj.'wor fa efflinv-IfuKirfld fnr asWiffrl mr) fin* Ar ^'�li p7mO .iC YTme J5k!rQii *",?l OC. R&QL"e71S' rqf-J�.L18C ryj Stars rd Rash fRYw�h1 hefirwa ro uled ' DI€�rrar '.- NIxI F.82Er� :. - Pafnr'tb L %n Jrritl[ 1�j hiion _ U11Mw.i — X' psl;'PLO70V aopc T*n� Y. ecw a'by asa 7?nns 7,f2.Frakc THE F_ RJ�aas pcW�edby rife R-i''rwj4mfjay — - FJGk- Trr4 3. hmaw Q9f Lure Trw — 4 RafnTAq?,mPhy l Da T. oc ZK.`ro'd�GrY'er�lrh7Sy 4z�.__�. am. f Tcgw aor* _ Y L h' �Vote:Ali ssrf{oles �re r 7 kGf130r JO" fr �ueEk5 f l77 reCrjpl Vr?k!�9 OWJc�:WfVC-frwjj�?&.rig m di' L ol 4i136WCMY ? Fla +WNlErr }s No-cwPlck f N f fYRFAl3lfT![iFJ: WhYrr. F YELLUVI-Refuv; ful'abcrafary widRSsrry 4R(Fj. PNT(-�:iawU3prlf Popy rAccwne: A! r UwbEr: ME C M2-01 Tm n� J W PACE ANALYTICAL SERVICES, LLC Sam plea RaCeipt Chaddist (SReI I l MUj.Br_j S) Revlsed;912912U21) ce4rta{y P r al Issu lnfl Authority. Pare ENV - WCOL Page 1 of I Sample Receipt Checklist (SRc) Clieu., 3LG _ C.OLACT 13)5PCCXd [p,104cc. J$I1 1 '.L.+CZ203t Lo. .: W_U00J71JMD[S 14lcans oJ' 1-t!"ipt; rate Cl[ent Ul-, i~CuEx Oltitir Yes d Ala _ _ [_ )Vwu custody 1,ee:5 present urr tiro MjUler7 - y%* Ar, NA 1 1Pcusr�d Seals �YnrG r,rasert, w m :Itcy inset a7d tin :mmlce117 rl' Strip I I]; 21.02 _ Chlarino Strip JD_- r'x' I rated hr asla terrlperatuve upotr rcoeipt I Derived (Corrected) I=peraturo upon receipt %uS olid Snap -Cup TT): NA Iorigins! 3.4 13.4 eC KA f NA a(; IxA 1NA ac NA MA oc — — MCthod; 71-1—tai urjoima3lank EJA48 )81 t3 #bm IRCii.-I ID; 1RG11.41.0urrerriaat ['actor. 4 Ge Meluxi Ofeaaiant_ 0 wet Zee Q Ice Pecs n TEO Lj YW 0Nt, EINA .3. if telrtl] raLur a` any cOnlrr weeded (i.0"[ , vas Project L+ianaPur N[�ifiad? PM was 1'U[i�ed by phone 1 err.aiI / faOitiLp-face (ci-4 r one). V Yes LLJJ N-D 11 NA 4. is Lhacoutke-vial co ulm-'s packiTlpslip idia;;hud to 9)is ra,rm? Yes LJ,.\el 5. Wee; praper c�stnr�w pra0edares (relinquisisal,'reci ivetl) falJawed7 d yihs Tr o G, VJe�e .pan) !e Ills li stud an ciao COC? ,f Yes N42 7_ Wlm, sample IDr, II&W art al] gArn [e co-LLaine:s? lr-es No 8- 'N45 SallecLiQn data & ttaw listcd are the CO "? [�Yes l �10 _ 9_ 'A'as coJlectign dwk& timelistCc onLI[so-uup[e cai:iairvss? - ,f Yes No 10. Did all conrainnr label irrrunnatiae (11], (f;'[e, time) agrec wsth the Coe? J Yes Nol P'_ Were ; Is t,tr lkr perfarrnl[stud oul rho CUC° I 2:1 If 12 Did all s,uF pics a.: [ve inN�� piuJ,er curLtai a yr fax oa rh test J oF&ar in Q-Noll (unbroken, I[da on, etc.)? bond ovndiliai ❑d yr,s L—I Na 13, Was adngtra a sample volumt< available?LZI - Yee QjqG 14. Were all tsmples rec-civcd within ;i Thelro]clij,g;rite or48 h9urs. tivhiohcvercomc5 fuse? Yes—ONa 15. Weia any sarin Je,t eoa;,tittet-s Iruasinj�'excess (circl,: Ogle) $:Rmpies Not Iisttid on C'[?C? E]Yes M Nu C]NA 16, Por VDA and RSK-17� sampJa; wurc bubbler pFOSpnE>"1rua�ixe" ('/."or 6min U: diamctar) a ire any afore VOA via[g"' ye� Flo AIA 17. Were all 1}RO;nietalslnutrien.somplez necaives l at a pH of < 2? ' s No ! NA ] $_ VdetC Ail cyanide .srlrnpks t euei v�vt xt a H 12 and s�u l edp sa7� [t 9 rCc� i Ye[1 ai: a pri .' C ), Mn .QN.A J J, %;'ere all �p icable NM,r T-'�Nlc� side e„ull 5, ]r60$ = 0,51rg,L} sa n}�1e3 fr4t residwd r'l,lrTine? Elyed ONO PINA 4_ Kira; rlirncieinurk3VrcqLws (iix. requeged d-Autiorv, M.1.fW3ll4asignaIicns, correctly transcribed from the CIX inm to the o ment sm. ion in LIMS? Yes V No ? 1. Vr'as the use n rnn bee li9cd 001 the rantaioer IabW1 If yQ, QLH)t�k # ample i'rct rrutiau [Must ba cam lcfcd fnr am' sttt>7ple(s} [np�et ctly pL+eI N'ed ar %vUj ccadspaoc_.) — aLuplaf } M ltere rocaived i1K4_M;aetJy Irresprved and were adjusted deco„ irlgly s Iuls]G n uoivin With NA_ _rtil, cf circle once. H2SO4, IN03, MC1, Nuo ij usiyc SR if NA ' W" 4� j}rC9RrV8ti�il NA - If mate t13a,I sine prZ-9- vMlivu is tmikd, please note in Commeris hr.luw_ >Irt plo(s ua _ war a teceikEd t}irh bubbJec >6 mm indirricter. rmpirs(s) 146 were rcocived wi!h '1'RC > 0.3 mgrL (Tf P 19 k itv) an d ivem [jimtcd accord in91Y ill suRlpie receiving wide sodiu.-n thiasulfRlc (Nacr2C)c) it[ti Slre0ly !J?- NA 8R harcade labe& applied lyy; { orrrntents: Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 58 of 58 0 aceAnalytical Report of Analysis Bunnell-Lammons Engineering, Inc. 6004 Ponders Court Greenville, SC 29615 Attention: Andy Alexander Project Name: Active Buncombe County Landfill LD Project Number: 9378-26A Lot Number:WK02030 Date Completed:12/07/2021 N N NO � � J 12/13/2021 11:51 AM Approved and released by: Project Manager II: Lucas Odom pCC/►F� 24r�A lkiA ANSI National Accreditation Board A C C R E D I T E D TESTING LABORATORY The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 1 of 65 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative Bunnell-Lammons Engineering, Inc. Lot Number: WK02030 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved The NELAC Institute (TNI) standards, the Pace Analytical Services, LLC ("Pace") Laboratory Quality Manual, standard operating procedures (SOPS), and Pace policies. Any exceptions to the TNI standards, the Laboratory Quality Manual, SOPs or policies are qualified on the results page or discussed below. Pace is a TNI accredited laboratory; however, the following analyses are currently not listed on our TNI scope of accreditation: Biological Tissue: All, Non -Potable Water: SGT-HEM EPA 1664B, Silica EPA 200.7, Boron, Calcium, Silicon, Strontium EPA 200.8, Bicarbonate, Carbonate, and Hydroxide Alkalinity SM 2320 B-2011, Fecal Coliform SM 9221 C E-2006 & SM 9222D-2006, Strontium SW-846 6010D, VOC SM 6200 B-2011, Drinking Water: VOC (excluding BTEX, MTBE, Naphthalene, & 1,2-dichloroethane) EPA 524.2, Solid Chemical Material: TOC Walkley-Black. If you have any questions regarding this report please contact the Pace Project Manager listed on the cover page. VOCs by GC/MS The following samples were diluted due to the nature of the sample matrix: WK02030-001, WK02030- 007. The LOQ has been elevated to reflect the dilution. The laboratory control sample (LCS) for analytical batch 22172 exceeded acceptance criteria for Acetone. This analyte is biased high but not detected in the samples affected. Sample -001 was received with a pH above 2.0. The pH was found to be 3.0. Reanalysis of the following sample was performed outside of the analytical holding time for 2-Butanone due to exceeding upper control limit: WK02030-005. Inorganic Non -Metals An additional dilution was needed for sample -010 Nitrate analysis. This dilution was performed outside of the 48 hour hold time. Subcontracted Analysis The analysis for BOD has been performed by Pace Asheville. This data has been ammended to this lot. Metals by ICP-MS The method blank associated with batch 21241 yielded a "J" value detection for Zinc. No corrective action is required as this is an estimated value recovered below the LOQ. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 whw.pacelabs.com Page 2 of 65 PACE ANALYTICAL SERVICES, LLC Sample Summary Bunnell-Lammons Engineering, Inc. Lot Number: WK02030 Sample Number Sample ID Matrix Date Sampled Date Received 001 Leachate Pond Aqueous 10/28/2021 1435 10/30/2021 002 Leachate LID Aqueous 10/28/2021 1450 10/30/2021 003 LD-2 Aqueous 10/28/20211505 10/30/2021 004 LD-5 Aqueous 10/28/20211520 10/30/2021 005 LD-1 Aqueous 10/28/20211535 10/30/2021 006 LD-3 Aqueous 10/28/20211550 10/30/2021 007 LD-4 Aqueous 10/28/20211610 10/30/2021 008 LD-6 Aqueous 10/28/20211620 10/30/2021 009 TB Aqueous 10/28/2021 10/30/2021 010 Leachate Pond Aqueous 11/03/2021 1255 11/04/2021 (10 samples) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 3 of 65 PACE ANALYTICAL SERVICES, LLC Detection Summary Bunnell-Lammons Engineering, Inc. Lot Number: WK02030 Sample Sample ID Matrix Parameter Method Result Q Units Page 001 Leachate Pond Aqueous COD SM 5220D- 1100 mg/L 7 001 Leachate Pond Aqueous Phosphorus 365.1 2.9 mg/L 7 001 Leachate Pond Aqueous Sulfate 9056A 17 mg/L 7 001 Leachate Pond Aqueous Acetone 8260D 80 JL ug/L 7 001 Leachate Pond Aqueous 2-Butanone (MEK) 8260D 25 J ug/L 7 001 Leachate Pond Aqueous Antimony 6020B 12 ug/L 8 001 Leachate Pond Aqueous Arsenic 6020B 39 ug/L 8 001 Leachate Pond Aqueous Barium 6020B 450 ug/L 8 001 Leachate Pond Aqueous Chromium 6020B 94 ug/L 8 001 Leachate Pond Aqueous Cobalt 6020B 22 ug/L 8 001 Leachate Pond Aqueous Copper 6020B 1.8 J ug/L 8 001 Leachate Pond Aqueous Lead 6020B 0.54 J ug/L 9 001 Leachate Pond Aqueous Nickel 6020B 89 ug/L 9 001 Leachate Pond Aqueous Selenium 6020B 1.8 J ug/L 9 001 Leachate Pond Aqueous Vanadium 6020B 41 ug/L 9 001 Leachate Pond Aqueous Zinc 6020B 19 B ug/L 9 002 Leachate LID Aqueous Barium 6020B 24 ug/L 11 002 Leachate LID Aqueous Beryllium 6020B 0.15 J ug/L 11 002 Leachate LID Aqueous Cobalt 6020B 24 ug/L 11 002 Leachate LID Aqueous Copper 6020B 7.9 ug/L 11 002 Leachate LID Aqueous Nickel 6020B 210 ug/L 11 002 Leachate LID Aqueous Selenium 6020B 1.4 J ug/L 11 002 Leachate LID Aqueous Zinc 6020B 100 B ug/L 11 003 LD-2 Aqueous 1,1-Dichloroethane 8260D 1.2 ug/L 12 003 LD-2 Aqueous cis- 1,2-Dichloroethene 8260D 0.45 J ug/L 12 003 LD-2 Aqueous Barium 6020B 110 ug/L 13 003 LD-2 Aqueous Chromium 6020B 3.2 J ug/L 13 003 LD-2 Aqueous Cobalt 6020B 23 ug/L 13 003 LD-2 Aqueous Copper 6020B 4.1 J ug/L 13 003 LD-2 Aqueous Lead 6020B 0.98 J ug/L 13 003 LD-2 Aqueous Nickel 6020B 25 ug/L 13 003 LD-2 Aqueous Vanadium 6020B 4.8 J ug/L 13 003 LD-2 Aqueous Zinc 6020B 18 B ug/L 13 004 LD-5 Aqueous 1,4-Dioxane 8260D (SIM) 1.6 J ug/L 14 004 LD-5 Aqueous 2-Butanone (MEK) 8260D 4.0 J ug/L 14 004 LD-5 Aqueous Barium 6020B 170 ug/L 15 004 LD-5 Aqueous Cobalt 6020B 78 ug/L 15 004 LD-5 Aqueous Nickel 6020B 21 ug/L 16 004 LD-5 Aqueous Zinc 6020B 2.9 BJ ug/L 16 005 LD-1 Aqueous Benzene 8260D 1.9 ug/L 17 005 LD-1 Aqueous 2-Butanone (MEK) 8260D 28 H ug/L 17 005 LD-1 Aqueous Chloroethane 8260D 0.91 J ug/L 17 005 LD-1 Aqueous 1,4-Dichlorobenzene 8260D 0.46 J ug/L 17 005 LD-1 Aqueous 1,1-Dichloroethane 8260D 0.59 J ug/L 17 005 LD-1 Aqueous Barium 6020B 1300 ug/L 18 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 4 of 65 Detection Summary (Continued) Lot Number: WK02030 Sample Sample ID Matrix Parameter Method Result Q Units Page 005 LID-1 Aqueous Chromium 6020B 1.6 J ug/L 18 005 LD-1 Aqueous Cobalt 6020B 270 ug/L 18 005 LID-1 Aqueous Nickel 6020B 60 ug/L 18 005 LID-1 Aqueous Selenium 6020B 1.8 J ug/L 18 005 LD-1 Aqueous Zinc 6020B 5.5 BJ ug/L 18 006 LD-3 Aqueous Vinyl chloride 8260D 0.82 J ug/L 20 006 LD-3 Aqueous Barium 6020B 220 ug/L 20 006 LD-3 Aqueous Cobalt 6020B 5.2 ug/L 20 006 LD-3 Aqueous Nickel 6020B 2.4 J ug/L 20 007 LD-4 Aqueous Antimony 6020B 0.96 J ug/L 22 007 LD-4 Aqueous Arsenic 6020B 4.1 ug/L 22 007 LD-4 Aqueous Barium 6020B 490 ug/L 22 007 LD-4 Aqueous Chromium 6020B 290 ug/L 22 007 LD-4 Aqueous Cobalt 6020B 11 ug/L 22 007 LD-4 Aqueous Copper 6020B 12 ug/L 22 007 LD-4 Aqueous Nickel 6020B 89 ug/L 22 007 LD-4 Aqueous Selenium 6020B 1.6 J ug/L 22 007 LD-4 Aqueous Vanadium 6020B 17 ug/L 22 007 LD-4 Aqueous Zinc 6020B 13 B ug/L 22 008 LD-6 Aqueous Barium 6020B 460 ug/L 24 008 LD-6 Aqueous Cobalt 6020B 98 ug/L 24 008 LD-6 Aqueous Nickel 6020B 4.4 J ug/L 24 008 LD-6 Aqueous Zinc 6020B 4.8 BJ ug/L 24 (68 detections) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 5 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-001 Description: Leachate Pond Matrix: Aqueous Date Sampled:10/28/2021 1435 Date Received:10/30/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 2 (COD) SM 5220D-2011 2 11/13/2021 1532 DAK 22412 1 (Phosphorus) 365.1 5 11/03/2021 1909 DMA 21192 1 (Sulfate) 9056A 10 11/03/2021 1650 AMR 21322 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run COD SM 5220D-2011 1100 40 40 mg/L 2 Phosphorus 7723-14-0 365.1 2.9 0.25 0.10 mg/L 1 Sulfate 9056A 17 10 2.5 mg/L 1 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 10 11/11/20211941 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 80 JL 200 50 ug/L 1 Acrylonitrile 107-13-1 8260D ND 200 8.0 ug/L 1 Benzene 71-43-2 8260D ND 10 4.0 ug/L 1 Bromochloromethane 74-97-5 8260D ND 10 4.0 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 10 4.0 ug/L 1 Bromoform 75-25-2 8260D ND 10 4.0 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 20 4.0 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 25 J 100 20 ug/L 1 Carbon disulfide 75-15-0 8260D ND 10 4.0 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 10 4.0 ug/L 1 Chlorobenzene 108-90-7 8260D ND 10 4.0 ug/L 1 Chloroethane 75-00-3 8260D ND 20 4.0 ug/L 1 Chloroform 67-66-3 8260D ND 10 4.0 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 10 5.0 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 10 4.0 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 10 4.0 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 10 4.0 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 10 4.0 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 20 5.0 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 10 4.0 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 10 4.0 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 10 4.0 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 10 4.0 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 10 4.0 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 10 4.0 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 10 4.0 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 10 4.0 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 10 4.0 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 6 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-001 Description: Leachate Pond Matrix: Aqueous Date Sampled:10/28/2021 1435 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 10 11/11/20211941 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,3-Dichloropropene 10061-02-6 8260D ND 10 4.0 ug/L 1 Ethylbenzene 100-41-4 8260D ND 10 4.0 ug/L 1 2-Hexanone 591-78-6 8260D ND 100 20 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 50 4.0 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 100 20 ug/L 1 Methylene chloride 75-09-2 8260D ND 10 4.0 ug/L 1 Styrene 100-42-5 8260D ND 10 4.1 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 10 4.0 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 10 4.0 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 10 4.0 ug/L 1 Toluene 108-88-3 8260D ND 10 4.0 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 10 4.0 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 10 4.0 ug/L 1 Trichloroethene 79-01-6 8260D ND 10 4.0 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 10 4.0 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 10 4.0 ug/L 1 Vinyl acetate 108-05-4 8260D ND 50 12 ug/L 1 Vinyl chloride 75-01-4 8260D ND 10 4.0 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 10 4.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 96 70-130 1,2-Dichloroethane-d4 114 70-130 Toluene-d8 103 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1728 BNW 11/07/2021 0954 21241 2 3005A 6020B 1 11/09/2021 1855 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 12 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 39 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 450 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 2 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 94 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 22 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.8 J 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 7 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-001 Description: Leachate Pond Matrix: Aqueous Date Sampled:10/28/2021 1435 Date Received:10/30/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1728 BNW 11/07/2021 0954 21241 2 3005A 6020B 1 11/09/2021 1855 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Lead 7439-92-1 6020B 0.54 J 1.0 0.25 ug/L 2 Nickel 7440-02-0 6020B 89 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.8 J 5.0 1.3 ug/L 2 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 41 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 19 B 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 8 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-002 Description: Leachate LD Matrix: Aqueous Date Sampled:10/28/2021 1450 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211542 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 9 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-002 Description: Leachate LD Matrix: Aqueous Date Sampled:10/28/2021 1450 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211542 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 100 70-130 1,2-Dichloroethane-d4 107 70-130 Toluene-d8 104 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1730 BNW 11/07/2021 0954 21241 2 3005A 6020B 1 11/09/2021 1242 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 24 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.15 J 0.40 0.15 ug/L 2 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 24 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 7.9 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 2 Nickel 7440-02-0 6020B 210 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.4 J 5.0 1.3 ug/L 2 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 100 B 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 10 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-003 Description: LD-2 Matrix: Aqueous Date Sampled:10/28/2021 1505 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211606 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D 1.2 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis-1,2-Dichloroethene 156-59-2 8260D 0.45 J 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 11 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-003 Description: LD-2 Matrix: Aqueous Date Sampled:10/28/2021 1505 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211606 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 105 70-130 Toluene-d8 103 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1732 BNW 11/07/2021 0954 21241 2 3005A 6020B 1 11/09/2021 1245 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 110 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 2 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.2 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 23 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 4.1 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.98 J 1.0 0.25 ug/L 2 Nickel 7440-02-0 6020B 25 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 2 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 4.8 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 18 B 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 12 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-004 Description: LD-5 Matrix: Aqueous Date Sampled:10/28/2021 1520 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 11/05/2021 2008 CAW 21469 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 1.6 J 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 87 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211630 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 4.0 J 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 13 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-004 Description: LD-5 Matrix: Aqueous Date Sampled:10/28/2021 1520 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211630 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 105 70-130 Toluene-d8 102 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1734 BNW 11/07/2021 0954 21241 2 3005A 6020B 1 11/09/2021 1251 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 170 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 2 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 78 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 2 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 14 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-004 Description: LD-5 Matrix: Aqueous Date Sampled:10/28/2021 1520 Date Received:10/30/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1734 BNW 11/07/2021 0954 21241 2 3005A 6020B 1 11/09/2021 1251 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Nickel 7440-02-0 6020B 21 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 2 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 2.9 BJ 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 15 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-005 Description: LD-1 Matrix: Aqueous Date Sampled:10/28/2021 1535 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211654 TML 22172 2 5030B 8260D 1 12/03/20211539 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D 1.9 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 28 H 10 2.0 ug/L 2 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.91 J 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.46 J 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.59 J 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 16 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-005 Description: LD-1 Matrix: Aqueous Date Sampled:10/28/2021 1535 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211654 TML 22172 2 5030B 8260D 1 12/03/20211539 BWS 24540 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 98 70-130 H 92 70-130 1,2-Dichloroethane-d4 105 70-130 H 124 70-130 Toluene-d8 107 70-130 H 108 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1736 BNW 11/07/2021 0954 21241 2 3005A 6020B 1 11/09/2021 1253 BNW 11/07/2021 0954 21241 3 3005A 6020B 5 11/09/2021 1255 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 1300 25 6.3 ug/L 3 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 2 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.6 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 270 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 2 Nickel 7440-02-0 6020B 60 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.8 J 5.0 1.3 ug/L 2 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.5 BJ 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 17 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-006 Description: LD-3 Matrix: Aqueous Date Sampled:10/28/2021 1550 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211718 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 18 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-006 Description: LD-3 Matrix: Aqueous Date Sampled:10/28/2021 1550 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211718 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.82 J 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 97 70-130 1,2-Dichloroethane-d4 112 70-130 Toluene-d8 106 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1738 BNW 11/07/2021 0954 21241 2 3005A 6020B 1 11/09/2021 1257 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 220 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 2 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.2 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 2 Nickel 7440-02-0 6020B 2.4 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 2 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 19 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-007 Description: LD-4 Matrix: Aqueous Date Sampled:10/28/2021 1610 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 10 11/11/20212004 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 200 50 ug/L Acrylonitrile 107-13-1 8260D ND 200 8.0 ug/L Benzene 71-43-2 8260D ND 10 4.0 ug/L Bromochloromethane 74-97-5 8260D ND 10 4.0 ug/L Bromodichloromethane 75-27-4 8260D ND 10 4.0 ug/L Bromoform 75-25-2 8260D ND 10 4.0 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 20 4.0 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 100 20 ug/L Carbon disulfide 75-15-0 8260D ND 10 4.0 ug/L Carbon tetrachloride 56-23-5 8260D ND 10 4.0 ug/L Chlorobenzene 108-90-7 8260D ND 10 4.0 ug/L Chloroethane 75-00-3 8260D ND 20 4.0 ug/L Chloroform 67-66-3 8260D ND 10 4.0 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 10 5.0 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 10 4.0 ug/L Dibromochloromethane 124-48-1 8260D ND 10 4.0 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 10 4.0 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 10 4.0 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 20 5.0 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 10 4.0 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 10 4.0 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 10 4.0 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 10 4.0 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 10 4.0 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 10 4.0 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 10 4.0 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 10 4.0 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 10 4.0 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 10 4.0 ug/L Ethylbenzene 100-41-4 8260D ND 10 4.0 ug/L 2-Hexanone 591-78-6 8260D ND 100 20 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 50 4.0 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 100 20 ug/L Methylene chloride 75-09-2 8260D ND 10 4.0 ug/L Styrene 100-42-5 8260D ND 10 4.1 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 10 4.0 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 10 4.0 ug/L Tetrachloroethene 127-18-4 8260D ND 10 4.0 ug/L Toluene 108-88-3 8260D ND 10 4.0 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 10 4.0 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 20 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-007 Description: LD-4 Matrix: Aqueous Date Sampled:10/28/2021 1610 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 10 11/11/20212004 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 10 4.0 ug/L 1 Trichloroethene 79-01-6 8260D ND 10 4.0 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND S 10 4.0 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 10 4.0 ug/L 1 Vinyl acetate 108-05-4 8260D ND 50 12 ug/L 1 Vinyl chloride 75-01-4 8260D ND 10 4.0 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 10 4.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 113 70-130 Toluene-d8 105 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1741 BNW 11/07/2021 0954 21241 2 3005A 6020B 1 11/09/2021 1259 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.96 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 4.1 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 490 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 2 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 290 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 11 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 12 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 2 Nickel 7440-02-0 6020B 89 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.6 J 5.0 1.3 ug/L 2 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 17 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 13 B 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 21 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-008 Description: LD-6 Matrix: Aqueous Date Sampled:10/28/2021 1620 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211742 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 22 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-008 Description: LD-6 Matrix: Aqueous Date Sampled:10/28/2021 1620 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211742 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 96 70-130 1,2-Dichloroethane-d4 108 70-130 Toluene-d8 105 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 11/08/2021 1743 BNW 11/07/2021 0954 21241 2 3005A 6020B 1 11/09/2021 1301 BNW 11/07/2021 0954 21241 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 460 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 2 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 98 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 2 Nickel 7440-02-0 6020B 4.4 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 2 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 4.8 BJ 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 23 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-009 Description: TB Matrix: Aqueous Date Sampled:10/28/2021 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211343 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 24 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory I D: WK02030-009 Description: TB Matrix: Aqueous Date Sampled:10/28/2021 Date Received:10/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 11/11/20211343 TML 22172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 95 70-130 112 70-130 106 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 25 of 65 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WK02030-010 Description: Leachate Pond Matrix: Aqueous Date Sampled:11/03/2021 1255 Date Received: 11 /04/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 2 (Nitrate - N) 9056A 25 11/05/2021 1252 AMR 21837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Nitrate - N 9056A ND H 0.50 0.13 mg/L 2 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 26 of 65 QC Summary Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 27 of 65 Inorganic non-metals - MB Sample ID: WQ21192-001 Matrix: Aqueous Batch: 21192 Analytical Method: 365.1 Parameter Result Q Dil LOQ DL Units Analysis Date Phosphorus ND 1 0.050 0.020 mg/L 11/03/2021 1820 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 28 of 65 Inorganic non-metals - LCS Sample ID: WQ21192-002 Matrix: Aqueous Batch: 21192 Analytical Method: 365.1 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Phosphorus 1.0 0.99 1 99 90-110 11/03/2021 1824 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 29 of 65 Inorganic non-metals - MB Sample ID: WQ21322-001 Matrix: Aqueous Batch: 21322 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate ND 1 1.0 0.25 mg/L 11/03/2021 1310 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 30 of 65 Inorganic non-metals - LCS Sample ID: WQ21322-002 Matrix: Aqueous Batch: 21322 Analytical Method: 9056A Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfate 20 20 1 102 80-120 11/03/2021 1440 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 31 of 65 Inorganic non-metals - MB Sample ID: WQ21837-001 Matrix: Aqueous Batch: 21837 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N ND 1 0.020 0.0050 mg/L 11/05/2021 1214 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 32 of 65 Inorganic non-metals - LCS Sample ID: WQ21837-002 Matrix: Aqueous Batch: 21837 Analytical Method: 9056A Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Nitrate - N 0.80 0.82 1 102 80-120 11/05/2021 1233 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 33 of 65 Inorganic non-metals - MB Sample ID: WQ22412-001 Matrix: Aqueous Batch: 22412 Analytical Method: SM 5220D-2011 Parameter Result Q Dil LOQ DL Units Analysis Date COD ND 1 20 20 mg/L 11/13/2021 1531 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 34 of 65 Inorganic non-metals - LCS Sample ID: WQ22412-002 Matrix: Aqueous Batch: 22412 Analytical Method: SM 5220D-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date COD 400 390 1 98 95-105 11/13/2021 1531 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 35 of 65 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: WQ21469-001 Matrix: Aqueous Batch: 21469 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane ND 1 3.0 1.0 ug/L 11/05/2021 1102 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 93 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 36 of 65 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: WQ21469-002 Matrix: Aqueous Batch: 21469 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 56 1 112 70-130 11/05/2021 1003 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 113 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 37 of 65 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ22172-001 Matrix: Aqueous Batch: 22172 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 11/11/2021 1254 Acrylonitrile ND 1 20 0.80 ug/L 11/11/2021 1254 Benzene ND 1 1.0 0.40 ug/L 11/11/2021 1254 Bromochloromethane ND 1 1.0 0.40 ug/L 11/11/2021 1254 Bromodichloromethane ND 1 1.0 0.40 ug/L 11/11/2021 1254 Bromoform ND 1 1.0 0.40 ug/L 11/11/2021 1254 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 11/11/2021 1254 2-Butanone (MEK) ND 1 10 2.0 ug/L 11/11/2021 1254 Carbon disulfide ND 1 1.0 0.40 ug/L 11/11/2021 1254 Carbon tetrachloride ND 1 1.0 0.40 ug/L 11/11/2021 1254 Chlorobenzene ND 1 1.0 0.40 ug/L 11/11/2021 1254 Chloroethane ND 1 2.0 0.40 ug/L 11/11/2021 1254 Chloroform ND 1 1.0 0.40 ug/L 11/11/2021 1254 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 11/11/2021 1254 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 11/11/2021 1254 Dibromochloromethane ND 1 1.0 0.40 ug/L 11/11/2021 1254 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 11/11/2021 1254 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 11/11/2021 1254 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 11/11/2021 1254 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/11/2021 1254 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 11/11/2021 1254 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 11/11/2021 1254 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 11/11/2021 1254 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 11/11/2021 1254 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/11/2021 1254 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 11/11/2021 1254 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 11/11/2021 1254 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/11/2021 1254 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 11/11/2021 1254 Ethylbenzene ND 1 1.0 0.40 ug/L 11/11/2021 1254 2-Hexanone ND 1 10 2.0 ug/L 11/11/2021 1254 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 11/11/2021 1254 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 11/11/2021 1254 Methylene chloride ND 1 1.0 0.40 ug/L 11/11/2021 1254 Styrene ND 1 1.0 0.41 ug/L 11/11/2021 1254 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/11/2021 1254 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 11/11/2021 1254 Tetrachloroethene ND 1 1.0 0.40 ug/L 11/11/2021 1254 Toluene ND 1 1.0 0.40 ug/L 11/11/2021 1254 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 11/11/2021 1254 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 11/11/2021 1254 Trichloroethene ND 1 1.0 0.40 ug/L 11/11/2021 1254 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 11/11/2021 1254 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 11/11/2021 1254 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 38 of 65 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ22172-001 Matrix: Aqueous Batch: 22172 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 11/11/2021 1254 Vinyl chloride ND 1 1.0 0.40 ug/L 11/11/2021 1254 Xylenes (total) ND 1 1.0 0.40 ug/L 11/11/2021 1254 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 110 70-130 Toluene-d8 103 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 39 of 65 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ22172-002 Matrix: Aqueous Batch: 22172 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 160 N 1 163 60-140 11/11/2021 1143 Acrylonitrile 100 110 1 115 70-130 11/11/2021 1143 Benzene 50 51 1 102 70-130 11/11/2021 1143 Bromochloromethane 50 50 1 101 70-130 11/11/2021 1143 Bromodichloromethane 50 51 1 102 70-130 11/11/2021 1143 Bromoform 50 49 1 98 70-130 11/11/2021 1143 Bromomethane (Methyl bromide) 50 47 1 95 70-130 11/11/2021 1143 2-Butanone (MEK) 100 120 1 124 70-130 11/11/2021 1143 Carbon disulfide 50 55 1 111 70-130 11/11/2021 1143 Carbon tetrachloride 50 52 1 105 70-130 11/11/2021 1143 Chlorobenzene 50 49 1 98 70-130 11/11/2021 1143 Chloroethane 50 56 1 111 70-130 11/11/2021 1143 Chloroform 50 51 1 102 70-130 11/11/2021 1143 Chloromethane (Methyl chloride) 50 58 1 116 60-140 11/11/2021 1143 1,2-Dibromo-3-chloropropane (DBCP) 50 55 1 111 70-130 11/11/2021 1143 Dibromochloromethane 50 50 1 101 70-130 11/11/2021 1143 1,2-Dibromoethane (EDB) 50 50 1 100 70-130 11/11/2021 1143 Dibromomethane (Methylene bromide) 50 51 1 103 70-130 11/11/2021 1143 trans- 1,4-Dichloro-2-butene 50 55 1 109 70-130 11/11/2021 1143 1,2-Dichlorobenzene 50 48 1 96 70-130 11/11/2021 1143 1,4-Dichlorobenzene 50 46 1 93 70-130 11/11/2021 1143 1,1-Dichloroethane 50 52 1 103 70-130 11/11/2021 1143 1,2-Dichloroethane 50 52 1 105 70-130 11/11/2021 1143 1,1-Dichloroethene 50 55 1 110 70-130 11/11/2021 1143 cis- 1,2-Dichloroethene 50 52 1 105 70-130 11/11/2021 1143 trans- 1,2-Dichloroethene 50 53 1 107 70-130 11/11/2021 1143 1,2-Dichloropropane 50 51 1 101 70-130 11/11/2021 1143 cis- 1,3-Dichloropropene 50 52 1 103 70-130 11/11/2021 1143 trans- 1,3-Dichloropropene 50 54 1 108 70-130 11/11/2021 1143 Ethylbenzene 50 51 1 101 70-130 11/11/2021 1143 2-Hexanone 100 120 1 116 70-130 11/11/2021 1143 Methyl iodide (lodomethane) 50 53 1 106 70-130 11/11/2021 1143 4-Methyl-2-pentanone 100 110 1 111 70-130 11/11/2021 1143 Methylene chloride 50 51 1 102 70-130 11/11/2021 1143 Styrene 50 53 1 106 70-130 11/11/2021 1143 1,1,1,2-Tetrachloroethane 50 49 1 99 70-130 11/11/2021 1143 1,1,2,2-Tetrachloroethane 50 49 1 98 70-130 11/11/2021 1143 Tetrachloroethene 50 48 1 96 70-130 11/11/2021 1143 Toluene 50 52 1 104 70-130 11/11/2021 1143 1,1,1-Trichloroethane 50 53 1 106 70-130 11/11/2021 1143 1,1,2-Trichloroethane 50 49 1 98 70-130 11/11/2021 1143 Trichloroethene 50 48 1 96 70-130 11/11/2021 1143 Trichlorofluoromethane 50 55 1 111 70-130 11/11/2021 1143 1,2,3-Trichloropropane 50 52 1 104 70-130 11/11/2021 1143 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 40 of 65 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ22172-002 Matrix: Aqueous Batch: 22172 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 45 1 91 60-140 11/11/2021 1143 Vinyl chloride 50 56 1 113 70-130 11/11/2021 1143 Xylenes (total) 100 110 1 105 70-130 11/11/2021 1143 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 96 70-130 1,2-Dichloroethane-d4 102 70-130 Toluene-d8 98 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 41 of 65 Volatile Organic Compounds by GC/MS - MS Sample ID: WK02030-007MS Matrix: Aqueous Batch: 22172 Prep Method: 5030E Analytical Method: 8260D Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone ND 1000 1100 10 111 60-140 11/11/2021 2028 Acrylonitrile ND 1000 1200 10 116 70-122 11/11/2021 2028 Benzene ND 500 580 10 115 70-130 11/11/2021 2028 Bromochloromethane ND 500 550 10 111 70-130 11/11/2021 2028 Bromodichloromethane ND 500 570 10 114 70-130 11/11/2021 2028 Bromoform ND 500 520 10 104 70-130 11/11/2021 2028 Bromomethane (Methyl bromide) ND 500 520 10 104 70-130 11/11/2021 2028 2-Butanone (MEK) ND 1000 1100 10 114 70-130 11/11/2021 2028 Carbon disulfide ND 500 640 10 128 70-130 11/11/2021 2028 Carbon tetrachloride ND 500 620 10 123 70-130 11/11/2021 2028 Chlorobenzene ND 500 540 10 107 70-130 11/11/2021 2028 Chloroethane ND 500 640 10 127 70-130 11/11/2021 2028 Chloroform ND 500 570 10 114 70-130 11/11/2021 2028 Chloromethane (Methyl chloride) ND 500 660 10 131 60-140 11/11/2021 2028 1,2-Dibromo-3-chloropropane (DBCP) ND 500 550 10 110 70-130 11/11/2021 2028 Dibromochloromethane ND 500 550 10 110 70-130 11/11/2021 2028 1,2-Dibromoethane (EDB) ND 500 530 10 106 70-130 11/11/2021 2028 Dibromomethane (Methylene bromide) ND 500 560 10 113 70-130 11/11/2021 2028 trans- 1,4-Dichloro-2-butene ND 500 510 10 103 70-130 11/11/2021 2028 1,2-Dichlorobenzene ND 500 510 10 103 70-130 11/11/2021 2028 1,4-Dichlorobenzene ND 500 490 10 98 70-130 11/11/2021 2028 1,1-Dichloroethane ND 500 580 10 116 70-130 11/11/2021 2028 1,2-Dichloroethane ND 500 580 10 115 70-130 11/11/2021 2028 1,1-Dichloroethene ND 500 650 10 129 70-130 11/11/2021 2028 cis- 1,2-Dichloroethene ND 500 580 10 115 70-130 11/11/2021 2028 trans- 1,2-Dichloroethene ND 500 600 10 119 70-130 11/11/2021 2028 1,2-Dichloropropane ND 500 560 10 112 70-130 11/11/2021 2028 cis- 1,3-Dichloropropene ND 500 550 10 109 70-130 11/11/2021 2028 trans- 1,3-Dichloropropene ND 500 570 10 114 70-130 11/11/2021 2028 Ethylbenzene ND 500 570 10 113 70-130 11/11/2021 2028 2-Hexanone ND 1000 1100 10 113 70-130 11/11/2021 2028 Methyl iodide (lodomethane) ND 500 590 10 119 70-130 11/11/2021 2028 4-Methyl-2-pentanone ND 1000 1100 10 115 70-130 11/11/2021 2028 Methylene chloride ND 500 570 10 114 70-130 11/11/2021 2028 Styrene ND 500 580 10 115 70-130 11/11/2021 2028 1,1,1,2-Tetrachloroethane ND 500 550 10 110 70-130 11/11/2021 2028 1,1,2,2-Tetrachloroethane ND 500 510 10 103 70-130 11/11/2021 2028 Tetrachloroethene ND 500 550 10 109 70-130 11/11/2021 2028 Toluene ND 500 570 10 115 70-130 11/11/2021 2028 1,1,1-Trichloroethane ND 500 610 10 122 70-130 11/11/2021 2028 1,1,2-Trichloroethane ND 500 520 10 105 70-130 11/11/2021 2028 Trichloroethene ND 500 540 10 108 70-130 11/11/2021 2028 Trichlorofluoromethane ND 500 660 N 10 131 70-130 11/11/2021 2028 1,2,3-Trichloropropane ND 500 520 10 104 70-130 11/11/2021 2028 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 42 of 65 Volatile Organic Compounds by GC/MS - MS Sample ID: WK02030-007MS Matrix: Aqueous Batch: 22172 Prep Method: 5030E Analytical Method: 8260D Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate ND 500 530 10 105 60-140 11/11/2021 2028 Vinyl chloride ND 500 650 10 130 70-130 11/11/2021 2028 Xylenes (total) ND 1000 1200 10 116 70-130 11/11/2021 2028 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 103 70-130 1,2-Dichloroethane-d4 111 70-130 Toluene-d8 108 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 43 of 65 Volatile Organic Compounds by GC/MS - MSD Sample ID: WK02030-007MD Matrix: Aqueous Batch: 22172 Prep Method: 5030E Analytical Method: 8260D Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Acetone ND 1000 1100 10 108 2.5 60-140 20 11/11/2021 2052 Acrylonitrile ND 1000 1200 10 116 0.045 70-122 20 11/11/2021 2052 Benzene ND 500 560 10 113 2.1 70-130 20 11/11/2021 2052 Bromochloromethane ND 500 540 10 108 2.2 70-130 20 11/11/2021 2052 Bromodichloromethane ND 500 560 10 113 0.74 70-130 20 11/11/2021 2052 Bromoform ND 500 520 10 104 0.17 70-130 20 11/11/2021 2052 Bromomethane (Methyl bromide) ND 500 500 10 100 3.9 70-130 20 11/11/2021 2052 2-Butanone (MEK) ND 1000 1100 10 112 2.3 70-130 20 11/11/2021 2052 Carbon disulfide ND 500 620 10 123 4.0 70-130 20 11/11/2021 2052 Carbon tetrachloride ND 500 610 10 122 0.87 70-130 20 11/11/2021 2052 Chlorobenzene ND 500 530 10 107 0.32 70-130 20 11/11/2021 2052 Chloroethane ND 500 620 10 123 3.3 70-130 20 11/11/2021 2052 Chloroform ND 500 570 10 113 1.2 70-130 20 11/11/2021 2052 Chloromethane (Methyl chloride) ND 500 640 10 127 3.1 60-140 20 11/11/2021 2052 1,2-Dibromo-3-chloropropane (DBCP) ND 500 570 10 113 3.1 70-130 20 11/11/2021 2052 Dibromochloromethane ND 500 550 10 110 0.42 70-130 20 11/11/2021 2052 1,2-Dibromoethane (EDB) ND 500 530 10 106 0.59 70-130 20 11/11/2021 2052 Dibromomethane (Methylene bromide) ND 500 550 10 110 2.3 70-130 20 11/11/2021 2052 trans- 1,4-Dichloro-2-butene ND 500 520 10 104 1.7 70-130 20 11/11/2021 2052 1,2-Dichlorobenzene ND 500 510 10 102 0.74 70-130 20 11/11/2021 2052 1,4-Dichlorobenzene ND 500 490 10 98 0.17 70-130 20 11/11/2021 2052 1,1-Dichloroethane ND 500 580 10 115 0.64 70-130 20 11/11/2021 2052 1,2-Dichloroethane ND 500 570 10 114 0.65 70-130 20 11/11/2021 2052 1,1-Dichloroethene ND 500 620 10 124 3.9 70-130 20 11/11/2021 2052 cis- 1,2-Dichloroethene ND 500 570 10 114 1.1 70-130 20 11/11/2021 2052 trans- 1,2-Dichloroethene ND 500 600 10 119 0.038 70-130 20 11/11/2021 2052 1,2-Dichloropropane ND 500 550 10 110 2.1 70-130 20 11/11/2021 2052 cis- 1,3-Dichloropropene ND 500 550 10 109 0.25 70-130 20 11/11/2021 2052 trans- 1,3-Dichloropropene ND 500 570 10 113 1.0 70-130 20 11/11/2021 2052 Ethylbenzene ND 500 570 10 113 0.16 70-130 20 11/11/2021 2052 2-Hexanone ND 1000 1100 10 115 1.0 70-130 20 11/11/2021 2052 Methyl iodide (lodomethane) ND 500 570 10 115 3.3 70-130 20 11/11/2021 2052 4-Methyl-2-pentanone ND 1000 1100 10 113 1.0 70-130 20 11/11/2021 2052 Methylene chloride ND 500 550 10 110 3.6 70-130 20 11/11/2021 2052 Styrene ND 500 570 10 114 1.0 70-130 20 11/11/2021 2052 1,1,1,2-Tetrachloroethane ND 500 540 10 108 2.0 70-130 20 11/11/2021 2052 1,1,2,2-Tetrachloroethane ND 500 530 10 105 2.1 70-130 20 11/11/2021 2052 Tetrachloroethene ND 500 540 10 107 2.1 70-130 20 11/11/2021 2052 Toluene ND 500 570 10 114 0.68 70-130 20 11/11/2021 2052 1,1,1-Trichloroethane ND 500 600 10 120 1.7 70-130 20 11/11/2021 2052 1,1,2-Trichloroethane ND 500 520 10 104 0.29 70-130 20 11/11/2021 2052 Trichloroethene ND 500 530 10 107 1.2 70-130 20 11/11/2021 2052 Trichlorofluoromethane ND 500 620 10 124 5.6 70-130 20 11/11/2021 2052 1,2,3-Trichloropropane ND 500 530 10 105 0.93 70-130 20 11/11/2021 2052 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 44 of 65 Volatile Organic Compounds by GC/MS - MSD Sample ID: WK02030-007MD Matrix: Aqueous Batch: 22172 Prep Method: 5030E Analytical Method: 8260D Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Vinyl acetate ND 500 510 10 102 2.7 60-140 20 11/11/2021 2052 Vinyl chloride ND 500 630 10 126 2.6 70-130 20 11/11/2021 2052 Xylenes (total) ND 1000 1200 10 116 0.25 70-130 20 11/11/2021 2052 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 103 70-130 1,2-Dichloroethane-d4 110 70-130 Toluene-d8 108 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 45 of 65 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ24540-001 Matrix: Aqueous Batch: 24540 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 2-Butanone (MEK) ND 1 10 2.0 ug/L 12/03/2021 1027 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 92 70-130 1,2-Dichloroethane-d4 123 70-130 Toluene-d8 107 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 46 of 65 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ24540-002 Matrix: Aqueous Batch: 24540 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 2-Butanone (MEK) 100 120 1 119 70-130 12/03/2021 0923 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 99 70-130 1,2-Dichloroethane-d4 102 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 47 of 65 ICP-MS Metals - MB Sample ID: WQ21241-001 Matrix: Aqueous Batch: 21241 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/07/2021 0954 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 11/08/2021 1659 Arsenic ND 1 2.0 1.3 ug/L 11/08/2021 1659 Barium ND 1 5.0 1.3 ug/L 11/08/2021 1659 Beryllium ND 1 0.40 0.15 ug/L 11/08/2021 1659 Cadmium ND 1 0.50 0.13 ug/L 11/08/2021 1659 Chromium ND 1 5.0 1.3 ug/L 11/08/2021 1659 Cobalt ND 1 5.0 1.3 ug/L 11/08/2021 1659 Copper ND 1 5.0 1.3 ug/L 11/08/2021 1659 Lead ND 1 1.0 0.25 ug/L 11/08/2021 1659 Nickel ND 1 5.0 1.3 ug/L 11/08/2021 1659 Selenium ND 1 5.0 1.3 ug/L 11/08/2021 1659 Silver ND 1 1.0 0.25 ug/L 11/08/2021 1659 Thallium ND 1 0.50 0.15 ug/L 11/08/2021 1659 Vanadium ND 1 5.0 2.5 ug/L 11/08/2021 1659 Zinc 3.2 J 1 10 2.5 ug/L 11/08/2021 1659 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 48 of 65 ICP-MS Metals - LCS Sample ID: WQ21241-002 Matrix: Aqueous Batch: 21241 Prep Method: 3005A Analytical Method: 6020B Prep Date: 11/07/2021 0954 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 97 1 97 80-120 11/08/2021 1701 Arsenic 100 99 1 99 80-120 11/08/2021 1701 Barium 100 93 1 93 80-120 11/08/2021 1701 Beryllium 100 110 1 105 80-120 11/08/2021 1701 Cadmium 100 100 1 100 80-120 11/08/2021 1701 Chromium 100 100 1 101 80-120 11/08/2021 1701 Cobalt 100 99 1 99 80-120 11/08/2021 1701 Copper 100 110 1 106 80-120 11/08/2021 1701 Lead 100 95 1 95 80-120 11/08/2021 1701 Nickel 100 100 1 103 80-120 11/08/2021 1701 Selenium 100 97 1 97 80-120 11/08/2021 1701 Silver 100 97 1 97 80-120 11/08/2021 1701 Thallium 100 93 1 93 80-120 11/08/2021 1701 Vanadium 100 100 1 101 80-120 11/08/2021 1701 Zinc 100 100 1 102 80-120 11/08/2021 1701 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 49 of 65 Chain of Custody and Miscellaneous Documents Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 50 of 65 �0 <CD m D ;v v CD C 0 0 C m v� o m N � r m n Cl o o � c m �CD n d �G -4 <, N 0 7 ib m O� co t CD C� V 0 co {p N b T w v tro x O v M O o, n E3 �e��trcal� Gilkrl�F rJd�dfess Fr'�Y r J 14 TW 3 `.J-c%JL A 1fii I°;mm Nd i�r.r{rrara ,6i-aarh aanyo� uajL� cp,�p!ShEd �� A7e S1e.� L4,6w PACE ANALYTECAIL SERVICES, LLC X Ynrrtuge Point Delve { Wost Crjurnbiu, SC 2017P T-1Iephnne -iD- 80n-791-9700 Fax tiro, &f 3-7�1 '�1 t 1 wy%'Lv.pacdEbS.cOm fr+;rx�7 �o-CmParP Seroluf« k &�T14�L5'e +3:7me�d ?tw'tdrxi Afa 1 &ewff (Anch a,sl d m:ro p1sA- 1. - tll l`O- Na. .�d f� 1:, of LYxtSM1m•sfA '•r b}'l-Yci�S\'dk'7 Twr _ffFfiT; ' �} WE F., X Number 127411 ihr.A-e hha °bys ! FT ��a�reslCaE+:rdp .i -- . — • •. i I I I f ..[_ I I I I I I 7krrn.Arasla� ilme firdruf�a ¢4aarrsb k7i rA dL+rer�2r R 7lT,J Same oa ar Pmflva I C �dSktirtT roRu , +YyJ 3ralnrl.` rd Alum? fspecilyf r'kWrll ;6 LkfW -.: --7Li-mg1r$'J.3 -- Nor-Fkmm r Fynma q _: €kiu h ileir :.' Pnl9oo- L !J*rxn t t Ramr.kb�e y Oarn ikna i- FacsrAgdTo'na Cy �y� Ae,�s y { _ ! i yi' fit; . r 2-.Oamvedby Dara TYW Y. r�rlYlrNr.�Serl b;� FGra Tara'x 3. F7ec�yiwsd ✓k' - fie re,r* #iefn r sati 1 sy ps ki abwarury face ved b Tbr ~ Ncrie: 4li �rr�pn —Ire "d U$w LMY rarJgo * I mfpw6 &thef a f'or)IW n7eptH .7r$ f am- DiSii��BfJriOr/: 'r4ifffF YFLLC44%F.WIl ry kw0wr9l} 4vdLh 3�3rrgJrpf °; mK-FNMrbc,.r C+Lm �- Gtzr{R}Gd Murber 6EM 2-Vi PACE ANALYTICAL SERVICES, LLC .� S:'MPl105 Reeeipt ChCddist (SRO �MEU018[-1$l Iwevised;W29j2020 Isscli,fl.luthorty: r Ue 2 UN-'M=C!_ Page 1 of 1 Simple Receipt Checklist (SRQ clieor; 31.r Covh4r Ins eC'etr hy1 l5rl r : I n:an.071 ors a: rcaerrt: J'd i liert i LP5 1 V-1 Fed N F7 611 r: — V VRS No SLJYis present on Cie co2ler? J Yea NO �J?1, if Cusu�rl 9rls 1ver resent, werelev intact taad tttlbrx7kun? ply strip 11J: 21 $si ahlorirto Strip ID- MA Test�i lr'7 — i ng�n l rcmpera:urc upon reo6pti DeAvW (Carrecn* lernpercWrc: upon r5NM. %Sulid Swap -Cap ID! NA 4.1 f4.7 HA +'NA aC NA INA ;C NA oNA a� Method- ❑T-eirp Li-oBJanrt gainst Do(tics III din„ in: } IR CAM Correction FActar: a kl' ,thod oY;.00lant: ❑ wet Ix ❑ Ice Prac:k.s ❑ Ury Inc ❑ NC1310 ❑'Ycs ❑NO ONA 3, after -1183 r•1Ce cfOnw cool-erexceeded 6.01T , wrjs prole Mwia rNotilla 121e PM was Notified by- phone r ern ail 1 fac.34r-rice (circle orrC)_ d `deal Na NA 4. Is the colnmrmial courier's packing slip aftacloerl to tVis forth? V YCE Nn Wpm P`nWcLL'cw WY Procedures (relingtlishcdrreteivcd) foliowetl2 { Yes No 6. W.,ro mmple Ids listed on the COC7 `has ❑ No !. Wffe Miple IDs listed on al ;ample ugrr obi ;? At ye -a No $. Wam collection dnto & time li6#ed on tlt4 WC? — ❑ Ve`' No y, Wa$ o0IJecdOn date & tirrfe listed cn all epinple coi:L tuirlcrsl a Los ❑ o rU_ UiG ill contairr<r Jabel in�prnmtion (iD, date, time) dgree wittt 03P, COC? 71 Yes No l J . Wert 1-051s to bo perfor mud listed on the CC+C? Yes ❑ 12, Did all sarnlrlcs jrr:ve in Iheptroper c:,,ntainen for each test andlor h good onndi:'on (nntrcokari, lids om, etc,)? _ +r cs IJ No 13.1Nas adequate. sample vcalume avalltabf$'� Yea + N 14. WBre all 5amglcs rece3x'ed wJJrirr I� the �Jclrng tirne or 48 hours, whjaCMr cause first' Yes +� yo 15_ LVtrc ten s rtrples cba7tairru" missittg'exccss {cite Ie one) &=g1cs Not liatrxl ell COC? ❑ ' s ❑ 12a ❑NA lii_ Par 1�OA a�ld UKJ73 s,]ntplas, yrere hobbles Jr, s:�l pea- i e+" ('r:,'or 4mun in Siam err} r all n[',Jrc VOA via!s't 5'4s Nn NA 17. Were all DR0jnteoalsfnuttjent samples received a# a R of < 27 Yes No J NA M Wm all rY&k iclta samples received at a pH > 12 and sllifirdc sa hplrs received :4l- a u FI � 9? — ❑ YcR El No ❑,t NA 19' Were AIT aplalicabl& N11je A'l;.yfni erpborte625_ Ii802i.3 [< 0._5M_ rL sanipies fee Uf residuid chlarine? ❑Yes �Nlo ��l:l0. Werc olien'renlark f:ayuets(i.e. r-gjmted dilutiorys, M2'MSD deftnaticrns,ctc..eorrectl}• {xanscrihed from ihm C oe into tits wilimellt seetion in UNIS? Yesf of a 9.1. Vk'as tFtc rluore nUmbar JLStec on the oomtaiycr labL-J? Tr'ves_ O:rore g S�tnp�e !*res�rvatian (�r±us. Ix aompl�red l47 #tn}sartp[C(s} ircnrrpr.tl}preserved or u�rlJt ileadspacc_1 . Sair331c(s) "A _ wale rumdved ?reor„cxtJy re3ervcd and uerc ad use J ttt caordinpry hi sartrtflc roceivin witty VA mL of elmle one- T12,904, HN00, HCJ, NaOH using SR # NA Titne efrtraseTvacion tom` lfrucrcthan onePreservttliyc is noedad,Plca,enoU; i:r ihvcnmmants belcrw. 5: tttp]c(sj tea — _ wetm received with IHaaSles ? 6 iT1nt in diarrtLArr. 1} }- were rrcaived with TJRC? 0.5 mVL (If �J9:srio ),end were �dj�s'ed aCCarCir!O}+ in sample rescivrnig wide sodigtn Momlfalt~ {Naas:R j rrith Skiealy ID. NA 5R harcade labels applied b3+: Ccunmrals', Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 52 of 65 �0 <CD m D vv CD C - 0 v 0 fn N < s tD CD � r CD n 0 ° c Q, 5 rn fn C 0 N m V <, N 0 3 W NO d Co rn N CD V 0 Co CD rn Co to m w 0 E3 CHAIN,OF-CUSTODYIAna tytical Request Document Ul@tgx 44%EIWV15V ALmlw;ntra'[rifrluetbeXMIGMaDctlfaley. a�a.lmegks.�rm SeellnoA 9edrnz8 SedlanC NOR: nF cWNd CI"o-rormalm Raquirad Prtljod MNM&Iir: inh als Inkr,yolou: ` F 1 Ir �i Lr -�I �• �r T mpan� HkF[ri lac real: 0 7 0' i_ 2 ' IJ_kLU.S O t,n Co4yTo {kp!igLr Htaire .._ mouaToRymi�kcY .. . ldurare: r *PDU J" GRQ0N7 WATER F OR WN0 WATER OnAT6. - -- FvrchasdCI;WNb.- Fo:eCv�L^ IJFsT �- RI'9A OiFiERC�rr�l.N�fx�.Cf rafavx� ahune: FdY. F'raSeT Vera:'C A I - fnhareaR�o,V1 aprI.COi�lon ir_�i5rti `o4 sr " { , fE-!queetW UVc OaleT TrU�c: Vrnwr. Rnglm te-d Ar+a "fr, Fltarad CFM' . • : . 84CIciu� Malex CoJerr RoG�lrotl�irl YrWrtnrlm ku rieix r C:inY s QQl_LE{;lEd Ff�$f4k*Vr,(.' s '} UrlrKN WON Uk%l Walef WT Y5`„sSaWalor W1ti'naerre [�GLR.3� I ? i.rff} IFI��I+I 01 0- I -..' �" i� f'a L SAMPLE jQ �f� wr Y k% 4r i S3r';d9I['*VUSTE-_-UN UL- TFw,* T$ .do Orno-r OT #} F 1 DATE TRdE ERTL TIME � � � x S S � c O � � Pacc P'roJcckMn r L nip 1 n x - - ' -. 6 6 .l« -7 I _ A.InrF43KAL COMMENTS RELINQUISHET59YFAFVILrATM '.PATE --'nXZ AJCEF'YW i}1'tAS I ILL51iUN UA PL' 'I IME SAMP1 F1'.iihrir1ONE �tl 3 A4 YPI I y � HL 11 lu 3AKrrLERW"IEAND GIZ;NATURE 0PL•.GINAL }OJT Y.i24T RaIIr,F 4T �AMPL.bZ� - �n"U •l+� E + o Pd SMATVREO9Ah. I.FR: VAIIE Slgf�d r i '.55iµi4tN�n Er L4��rN �i. roirt+,a�a+c:u:.Ni,rF�,1sNZ 3{+►fx�+f��r,1x:��a.ucrxwsr�h47. +�r��n �11.EaRa m:rr�i� arty lmvkrK nil ia/tlwfh ��Ntla}e F•}5LL-�OQC�'�1�, �5-h1a?`294� W PACE ANALYTICAL SERVICES, LLC Samplcs Receipt Checklist (SRC (r01ILDD18G1S) Revised-9,f�/2020 c � Y!�+ Essuir1jjAtcharity, Paoe ENV -W-COL Page 1 01 anl;p]e keceh)( Chtekiist (SRC) Client; rdr,t` Gaoler Jm acred b '1441C; JR❑3 e I Il9+?11C1 l.nt ir' WNW(130 Meam.uFL- ipl: Paco Client I., PS V red EX Otlyer. 5r'es v' Nro J . Wcm custody seals present on. rye cooker'? Y No y 7NA 12. ki eustody s--Is iverelnreseq were ;hav it]MO and Ulllj- IkCJ37 p H Strip ]D: I" _ C;h lorine Strip 1D: JqA Tested by "A Original =peratum upon reccipt O' Darived (Carnacted) tempmalprc upon rcc2ipr YQSolld Saap Cup ID: NA 1-3 ae NA INA oC NA /NA cC NA j34A aC - Mel=i4d; Z omperatum BlaiA [3k�irkq l3attl, s IR Gull ID: $ 1R Gun Comaction Factor- 0 M21hnd nrr.colant 0 WetTce d lct,F'acks 0 Uly kcR .Q plane ❑ yus No [Z]NA 3. It temperWmm of any caalor deeded 6.0°C, was PrnjrrI MnnstFr Notttled" PM wm Kotifted by: :ions ? em4i1 / face-to-face Ccirulo imc). Ycs3 No NA 4_ Is t_e ,euurrnemial caurier's paCMHg sl ip HLt:+chM tr, tt}is farm? 5. Were proper custody procedures (retinqu:sltcXm-.t::vcd) fol lojved2 6. Weve samplo IDs listed on the G' c? l Ycsf Lj No ,l Yes NO d Yea No '7_ Were Lample JIM listed on at: �HFUPlc cantain4rs;" 771 Yes LJ No 8_ Was Col laotion care & ti me I Is xd on. tho CUC 2 9. Wus calbm ion date& time Ikfiledan Hll sample comajoem? l tt_ Did all wontainer 'abel information (1D, d+rtc, time) a e with the COG? d Yes 77 Nu ❑ No. Yes my— Flo . 1. Wurc t: a� to be perfntrn&J F VLP j on tlra COC7 12. Did a:1 sam;sles arrive in the prop-. conta;nem for each test �xndJor in good condikipn _ rJ `i Yeti ��a (iw-inArn, lido on, n[r_,]? -ISO 13. Was adequato sn nt k volume ava:lilb'47 9J9'cs Yos lrr, 14. Wtru Hll ss,mp;ng received wtihin � the Folding tune or 4,8 Ilou-B, whirl-mrrcomes first? ym 1 'N.C. J 5, Alem any sam plc& cer.m4icrs Iniss UI. *iexc-6 (6mlc one) camp les Not 1JSk4'tl +x] CO ? ❑ Y ❑ No ❑, 16. For VUA and RSK-17S szrnplets, wom bubbles pien;c,iL>" pea-siZc' f'!,"or 51nm in diam�tr ) :tr. pry uf;hc VOA vials' 17. Were all DROinieE^als,+uutrient recci vcd at a o k-1 af< 2? IS, Were all cyanide sarnplw rmcivrd at.9 pi i } 12 2md sulfide sar:taleg received a:_ a pr15 W 1 U 7qa LJJNAJ ❑ Yes Nu d NA ❑ Ycs ❑ He, ❑NA 19_ Vdnrc T,Ik a „sa e iwl!! �T +7�l cyarit coo i633, I ItiGS.3 (t. F.79g(L) samPIts free o' rsid; ai c--Ilzrin_? ❑ Ycs ❑ No Lvj A 0. Wcrc cltcnt rcn1arkcVregne.ls {i. , rar.0ested dilutao=rs, WMSD dcsi+gnadons, em... j r orrc rely trFnscr:hed fmin the f'.GC into die comment stmticn in LIMS? ycs No 21. I�+as rho acre n6w—bor I-stcd on 11% CCmlutiiar IHhal4 1Fye.5, Quote P �ample Fr�crti+utaon �lMlnst be completed ftir�rY sample{sj J1YcorrecJq 1;rrscr�'+J rsr €t�itl� kreadspare.j %jrnple(e) 14* wen twHivmd :ncarre-- ly preserved and wcrc adjusted accordin.* in .sa-npie roceivbtg WAIL ran mL of c hie one: k-13904. l NO3, HCJ, NaOH using SR 4 "" _ Tune cf pr,eservalion NA if more than one pr'eszm, Hve is neeced, plu sc nut.- in the ewrimena 3alnw. mple(a) rdA were recei;red ,;v itkr mm in diam eter_ Salnpics(S) NA wow received with TRC > 0.5 mp'L (iiI1� Is he) anti Vier_ adjusted accntrliingly in sample receiv-no wick sodium thiosujfaU (Ka,S,Or) witlt Sheay ID- MA 4R herc,otie labels a-3plied by: JR93 l a0c: Ill 4P202r Comments: Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 54 of 65 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 November 04, 2021 Lucas Odom Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 RE: Project: WK02030 BLE Pace Project No.: 92570350 Dear Lucas Odom: Enclosed are the analytical results for sample(s) received by the laboratory on November 03, 2021. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services - Asheville If you have any questions concerning this report, please feel free to contact me. Sincerely, Sara Poulson sara.poulson@pacelabs.com (704)875-9092 Project Manager Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 55 of 65 Page 1 of 11 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: WK02030 BLE Pace Project No.: 92570350 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 North Carolina Drinking Water Certification #: 37712 CERTIFICATIONS North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 56 of 65 Page 2 of 11 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 SAMPLE ANALYTE COUNT Project: WK02030 BLE Pace Project No.: 92570350 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92570350001 LEACHATE POND SM 521OB-2016 NFW 1 PASI-A PASI-A = Pace Analytical Services - Asheville REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 11 Page 57 of 65 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: WK02030 BLE Pace Project No.: 92570350 Sample: LEACHATE POND Lab ID: 92570350001 Collected: 10/28/21 14:35 Received: 11/03/21 14:10 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 5210B BOD, 5 day Analytical Method: SM 521OB-2016 Pace Analytical Services -Asheville BOD, 5 day 49.0 mg/L 2.0 1 10/30/21 05:48 11/04/21 03:50 B2,H3 Date: 11/04/2021 04:50 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 58 of 65 Page 4 of 11 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: WK02030 BLE Pace Project No.: 92570350 QC Batch: 657279 Analysis Method: SM 521 OB-2016 QC Batch Method: SM 521OB-2016 Analysis Description: 5210E BOD, 5 day Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92570350001 METHOD BLANK: 3445474 Associated Lab Samples: 92570350001 Parameter Units BOD, 5 day mg/L LABORATORY CONTROL SAMPLE: 3445476 Parameter Units BOD, 5 day mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.0 11 /04/21 03:23 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 198 212 107 84.6-115 SAMPLE DUPLICATE: 3445477 92569626004 Dup Parameter Units Result Result BOD, 5 day mg/L 12000 ug/L 13.8 RPD Qualifiers 14 B2 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /04/2021 04:50 PM without the written consent of Pace Analytical Services, LLC. Page 59 of 65 Page 5 of 11 Pace Analytical Services, LLC lac, Analyilcal ® 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 www.pacelabs.com (704)875-9092 QUALIFIERS Project: WK02030 BLE Pace Project No.: 92570350 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TN -The NELAC Institute. ANALYTE QUALIFIERS B2 Oxygen usage is less than 2.0 for all dilutions set. The reported value is an estimated less than value and is calculated for the dilution using the most amount of sample. H3 Sample was received or analysis requested beyond the recognized method holding time. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /04/2021 04:50 PM without the written consent of Pace Analytical Services, LLC. Page 60 of 65 Page 6 of 11 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: WK02030 BLE Pace Project No.: 92570350 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92570350001 LEACHATE POND SM 521OB-2016 657279 SM 521OB-2016 657295 Date: 11/04/2021 04:50 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 61 of 65 Page 7 of 11 acaAnalyfbl' r Document N a me: Sam le Candttlon Upon Recelpl(SCUR) oocument Revised: October 28, 2020 Page 1 of 2 Document No,: F•CAR-0-033•Rev,07 Issuing Authority: Pace Carolin9sQu0litY0ffTCe Laboratory receiving samples: Asheville ❑ Eden❑ Greenwood ❑ Huntersville ❑ Raleigh[) Mechanicsville❑ Atlanta❑ Kernersville❑ Saws • Condition Client Name: . 92570350 r, 7 Project g:WO# Courier: ❑Fed Etc ❑UPS ❑USPS ❑Client �1 11� ��{ l ��� 1 l ❑Commercial ❑Pace []other:—L82570350 I 1 i11 1 Custody Seal Present? []Yes ❑No Seals Intact? ❑Yes ❑No Date/Iniliafs Person ExantiningCantents: / 11`9 Packing Material: ❑Bubble Wrap ❑Oubble Bags []hone ❑ Other Biological Tissue Frozen? QN/A ❑Yes ❑No Thermometer: ❑Wet ❑lllue ❑NoAe ( IFt Gun ID: e;f r + Type of Ice: Correction Factor: Cooler Temp: Add/5ubtract (T) t ' Temp should be above freezing to VC ❑Samples oui of temp criteria. Samples on ice, cooling process Cooler Temp Corrected ('0: basbegun USDA Regulated SOIL ( [} NIA, ,Aaler samples Did samples originate in'a quarantine zone within the United rr.. States: CA, NY, or 5C (check maps)? Did samples originate from a foreign source [internationally, lnrli,arnnA.... Ii aad 17ijrrm Wca17l`IYes nNo Co mments/Discrepancy: Chi In of Custody Present? }Yes []Ito ❑NJA ]. Samples Arrived wl thin [told Time? i ❑Yes ❑No ❑N!A 2. Sho rt Hold Time Analysis 102 hf,)? Ycs ❑No ❑N/A 3. Rus h Turn Around Time Requested? OYes ON.__ ❑N/A 4. StIfflcient VOtame? 0yes ❑No ❑N1A 5. Correct Containers Used? -Pace Containers Used? }Yes ©Yas ❑No []No ❑H/A NIA 6. Containers Intact? Qyes ❑Na ©N/A 7, Dissolved analysis: Samples Field Flitered? Dyes ❑Na ' N/A 8• Sample Labels Match COO •lRcludesDate/Tine/lD/Aiialpsls Matrix:__ 14eadspace In VOA Vials (>5-6ntnt)? ❑Yes j ❑Yes ONO [:]No ❑NIA ©NIA. 9. I 10. Trip BiankPresent? Trip Blank Custody Seals Present? ❑Yes []Yes ONO ONO [(tt/A rVA 11. COMMENTS/SAMPLE DISCREPANCY CLIENT NOTIFICATION/RESOLUTION Person contacted: Project Manager SCURF Review: Project Manager SRF Review: Date/Time, Lot ID of split containers: Date; Date: Field Data Required? ❑Ycs [IN* Page 62 of 65 Page 8 of 11 .,. aceAnalytica!' r Document {Name: Conditfan Upon Rece€ Document No.: F-CAR•CS-033-Rev.07 *Check mark top Ralf of box if pH and/or dechlorination is verified and within the acceptance range for preservation samples, Exceptforts: VOA, Collfurm,TOC, Oil and Grease, DRO/8015 {viater) DOC, Mig tweattom half of box Is to list number of battles Document Revisgcl: October 28, 2020 CUR) Page 2 of 2 fssu€ngAuthority: Project lWOff : 92570350 PM: SG Due Date: 11/10/21 CLIENT: 92-Pa,;e5hea1 u — u z z z ZZ n N .t z FtA Vv Qa nv n ° a 2 2 O u = v n a a a a `:_ m Z � r a az a O _ A C7 L j N 5 E Q �. N. Q aZ N y A 3 Z > c O C a EE a E d ( Q ��`, o p O Q o H N 1 JV)¢ j E E E v `u u F v E m c E ° E E E of >c N Val rr 9 ��., M ,N., N rl •� V LL 7 K ! N 7 N yy ry v1 6 ¢ q L F- p d 7 q 0_ v v Y ,r..,r `: y N a G N a P m E `� 7 Q a a a vA i Z a a rr a 0 rr to fir U ri Mi ttoa VI Q m > N > T Q > U > VI In N Vt m m Ln ca m m ro ro w m m 3 a ¢ ¢ 4 d d a 1 — i 7 10 tl tzN\ pH Adjustment Log for Preserved Samples Sample to Type of Presefvat€ve pH upon receipt oats preseruJtlon adjusted Time preservation Amount or Preservative lot U adjusted added Nate: wflenever Share Is a discfepar}Sy alfecllnl; ilort€7 Carol}na compliance samples, a copy of this lorm win ce sent CO [I a @ortn CarOnna ptrlfVSS C@rniiWUOn Uln[e p.e. Out of hold, mwrrect preservative, out of temp, incorrect containers. Page 9 of Page 63 of 65 Chain of Custody Workorder: WK02030 Workorder Name: Active Buncombe Leachate Owner Received Date: Report To: Subcontract To: Lucas J. Odom Project # 9378-26A Pace Analytical 106 Vantage Point Drive Pace Asheville Columbia SC, 29223 803-206-9537 iucas.odomCu7pacelabs_com ;Preserved containers Sample Collect z m Item Sample ID- Type Date/Time ' Lab ID " Matrix 1 Leachate Pond grab 10/29/2021 @ 1435 WK02030-001 Aqueous x X 2 3 4 5 6 ;7 18 9 10 Transfers Released By Date/Time Reveived By' Date/Time 1 2 aceAnalv6cal' r Results Requested By: 11/10/2C Requested Analysis Comments IL 1 Z.5 733,5C3 !AS USE ONLY Cooler Temperature on Receipt �CI Custody Seal Y or N Received on Ice Y or N I sample Intact Y or N ***In order to maintain client confidentiality, location/name of the sampling site, sampler's name and signature may not be provided on this COC This chain of custody is considered complete as is since this information is available in the owner laboratory. Friday, June 17, 2016 11:01:34 AM FMT-ALL-C-002rev_00 24March2009 Page 1 of 1 1.10 1.1• 96ed 593° S9 aged Ship to : aceAi2alytical f Pace Asheville Phone INTER LABORATORY WORK ORDER q W K02030 (To be complete by sending tab) Sending Project No: WK02030 Receiving Project No: Check Box for Consolidated Invoice: x Date Prepared: 3-Nov REQUESTED COMPLETION DATE: 11-Nov Sending Region IR77-SC Sending Project Mgr. LJO Receiving Region Asheville External Client BLE State of Sample origin NC Q L2 All questions should be addressed to sending project manager. Requested Reportable Units mg/L Report Wet or Dry Weight? Cert Needed: WORK.REQUESTED :.. uan y o Quantity o . Method Description Container Type containers ' Preservattva . samples.::; Unit Price 'Amount BOD plastic 1 none 1 25 25 TOTAL 25 Speclal RequlremenW Acctg,Code. Totals from above Revenue Allocation Receiving Reglon Department Receiving Region Client Services Dept. (80%) Sending Region (20%) 25 20 5 "Custom Revenue AllDcatlon TOTAL 20 5 FOR ANALYTICAL WORK COMPLETED THIS SECTION ALSO Chain of Custody Included: x Yes =No Return Samples to Sending Regulon: Yes x No Matrix: ❑ 50H water F]Air Other (identity) CaNFIRMATION;OF WORK.COMPLETED ' Date Completed: Receiving Project Manager: Original sent to the receiving lab - Copy kept at the sending lab. when work completed: Original sent to the ABM at the receiving laboratory. Copies are made to corporate as needed. Friday, )une 17, 2016 11:01:35 AM FMT-ALL-C-001 fev.00 24March2009 Page 1 of 1