Loading...
HomeMy WebLinkAboutNCS00520_INSP_20211110FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 2 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Guilford Closed MSWLF HHW White goods Incin T&P FIRM X PERMIT NO.: NCS-00520 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE Date of Site Inspection: 11/10/2021 Date of Last Inspection: FACILITY NAME AND ADDRESS: Mr. Johnny Wilson Wilson Pumping Service 8023 NC Hwy 68 N Stokesdale, NC 27357 GPS COORDINATES: N: NA E: NA FACILITY CONTACT INFORMATION: Name: Mr. Johnny Wilson Address: Same as above Telephone: 336-706-7458 Email address: dukewilson50@yahoo.com PARTICIPANTS: Chester Cobb (DWM) and Johnny Wilson STATUS OF PERMIT: Active EXPIRES: 12/31/2021 PURPOSE OF SITE VISIT: New Vehicle STATUS OF PAST NOTED VIOLATIONS: NA OBSERVED VIOLATIONS: NONE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 ADDITIONAL COMMENTS 1) Pumper vehicle(s) inspected: TRUCK LICENSE PLATE # VIN # TANK CAPACITY (gal) YA151532 1FVXJJCB1YHG77867 3,000 2) The required information of Firm name, town name, phone #, and permit # was on both sides of the pumper vehicle. Each letter of the required information was greater than three (3) inches in height. The lettering was distinguishable and not blocked from view. The lettering meets the requirements of 15A NCAC 13B .0835(b). See pictures below. 3) The tank is made of steel and affixed to the frame of the truck as per 15A NCAC 13B .0835(a)(1). 4) The valves appeared to be in working order and closed as per 15A NCAC 13B .0835(a)(2). Caps present on most ports. Cap missing on one port. Need to have cap on port. 5) Access ports were closed and properly sealed as per 15A NCAC 13B .0835(a)(3). 6) No leaks noticed as per 15A NCAC 13B .0835(a). Driver side of pumper vehicle. Cap missing on one port. Please place cap on port. Please contact me if you have any questions or concerns regarding this inspection report. ____________________________________________ Phone: (919) 707-8283 . Chester R. Cobb, Environmental Program Consultant Division of Waste Management, NCDEQ Regional Representative Sent on: X Email Hand delivery US Mail Certified No. [ _]