Loading...
HomeMy WebLinkAbout8102_Rutherford_South_MSWLF_Oct2021LFG_FID1636404_20220111NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice. This form and any information attached to it are 'Public Records"as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Rutherford County Landfill South - MSWLF (CLOSED) permit Number: Sampling Date: �) 13 9 Sample Collector Name & Position: NC Landfill Rule (.0500 or.1600): Jeff Nicholson - Field Services Manager 8102-MSWLF 0.500 Gas Meter Type & Serial Number:GEM 5000 S/N QG !�06 Q A Gas Meter Calibration Date: - 16 - a r Field Calibration Date & Time: I u- i I- a I , `, +0 A l Q r Field Calibration Gas Type (15115 o 5/50 Field Calibration Gas Canister Expiration Date: Gas Meter Pump Rate: N/M o Ambient Air Temperature: & Barometric Pressure (in. or mm Hg): )5 ' a Weather Conditions: O V Lo-C4 Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) a 20 = % LEL. *'hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial ova LEL Stabilized %LEL % CH4 volume (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTE ,� 'a 4 Y,, �i � r�, j Building #1 - t} I vv O J, 4 0,15 04, a I Building #2 r : 7 60 'O O O. U a0.1 0.0 Q C)� I Building #3 (210 q b O .O (90.-� 0.0 je,. )l LFG - 11 e/ 0,0 1 Q•C) ,, b).. �. a I LFG -10 �� SV (/ba VV q/ V �) V) 0,0 �, �1.� O Z>q-, aL LFG -8VENT 1v-40 Ij� (� 0,0 ,�_� ©-� © &q,a LFG- 7 VENT LFG-6 6 Q 0.6 101,0 a: O ID 1., a'„L LFG-5 10-,Io 40 0 �O 6,0 y, O 1qc? al LFG 4 VENT 4 in � 0 �! a Q ` -0A 1 a-7. LFG-3 m 6u o J 0,0 a0, gnad LFG-2 C O 0-0 1 `` O aq.aa NOTE: Ifneeded, attach additional datafors to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification inelud'ng the possibility of a fine and imprisonment. VJField Services Manager SIGNA'T TITLE Revised — February 4, 2020 y NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). FacilityName: Rutherford County Landfill South - MSWLF (CLOSED) PennitNumber: Sampling Date: 19 - It - a ( NC Landfill Rule (.0500 or.1600): 8102-MSWLF 0.500 Sample Collector Name & Position: Jeff Nicholson - Field Services Manager Type GEM 5000 S/N06 (, �p Gas Meter T e &Serial Number: � 3 �I Gas Meter Calibration Date: b a' � Field Calibration Date & Time: 10 - 11 -CA Field Calibration Gas Type (15115 oico): Field Calibration Gas Canister Expiration Date: a( - Gas Meter Pump Rate: N/M Ambient Air Temperature: �_Barometric Pressure (in. or mm Hg):( •' a� Weather Conditions: U►r4'C�j Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) g 20 = %LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 volume ( ) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES !„nr;�/•c 0-75I LFG-1 [ •,aJ 60 0 O O- Q q,0 a.0 O q•ad LFG -13 ( 1'.ob &0 0--p do,q .0.1 0 aS. as LFG -12 ,'.0 (70 _ O.0 6.0 (0 a13. Ja LFG -14 day C7 0 `0,91 C' LFG - 15 I , K U b ? 1100 �. a �., • 5' r7�1. d LFG -16 •40 U 0 Q 0.0 111- da Y LFG-a q l .t(� >ld -0 0 10,0 aQ 0-0 O t NOTE: Ifneeded, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or cc 'fication 'iicluding the possibility of a fine and imprisonment. Field Services Manager SIG A RE TITLE Revised —February 4, 2020 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records"as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Rutherford County Landfill Central - C&D $,l03-CDLF Facility Name: Permit Number: ' Sampling Date: + ^ l - S I NC Landfill Rule (.0500 or .1600): 1600 Sample Collector Name & Position: Jeff Nicholson - Field Services Manager ,+ Gas Meter Type & Serial Nu rn her:_ GE kM`` 5000 S/N �(J{� 3 u Gas Meter Calibration Date:. - C b - of Field Calibration Date & Time: I 0 - l 1 f ai /' I d q5- Field Calibration Gas Type (15115 or (0: Field Calibration Gas Canister Expiration Date: -( - a Gas Meter Pump Rate: N/M Ambient Air Temperature: Barometric Pressure (in. or minHg): D.R� Weather Conditions: S L-,- ILy Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or driving. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to^% LEL as follows: % methane (by volume) a 20 = % LEL. *hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized LEL % % CH4 volume (volume) ohs 02 (volume) % CO2 (volume) % H2S' (volume) NOTES AA Iy 111eA. e . �t Background �a`;�o W b 0,0 au"I p `a S,i-j Animal Shelter ASS G U d O. 0 90A B a'8. " Scale House i 3'- oj h V u 0_ 0 00,e1 a il 9 Storage Room ( 13 `.d1 G V . O Pom 0.. a � 3, 1�r'ff1 Malntemanoe Shop ' '. Treriafer Station N1 I Is '` iL O O+ 0 W Transfer elation## LFG-1 a i .� �ti S./ LFG - 2 10 O, a t9. ( o LFG - 3 %4� 60 a 0 0.0 16- 01 % O C-A. L LFG - 4 r 3�u'7 b y O 10 0-0 9- C� cq>5 A LFG - 5 IT-10 o o '0 6), 0 13 j (,, O 07. /6 NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5616 by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for malting any false statement, representation, or certifiti o including the possibility of a fine and imprisonment. A — Field Services Manager SIGNA TITLE Revised — February 4, 2020 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice. This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Rutherford County Landfill Central - C&D Permit Number: 8103-CDLF Sampling Date: �) - I � ' a l NC Landfill Rule (.0500 or .1600): 1600 Sample Collector Name & Position: Jeff Nicholson - Field Services Manager Gas Meter Type & Serial dumber: GEM 5000 S/N G O¢j �3 Gas Meter Calibration Date: '8—i 6 - Field Calibration Date & Time: Field Calibration Gas Type (15115 o 170 : Field Calibration Gas Canister Expiration Date: -al-2 Gas Meter Pump Rate: N/M Ambient Air Temperature: t-)'$ Barometric Pressure (in. or mm Hg): 099 • G'L Weather Conditions: S^ M1/ Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) a 20 = %LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES 1.6fr$� LFG - 1p '1 I o 0 0,0 ffQ 1 1. 11 O �q C/ I. va LFG - L �6 ( ` `a30 60 O O , a 3.$ i 3olq as LFG -11 K,Sy 5? NOTE: Ifneeded, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Field Services Manager SIGNATU Uf v TITLE Revised —February 4, 2020 iPJt,A Calibration No. 66916 Date Of Calibration: 16-Aug-2021 Customer: EASTERN SOLUTIONS LLC 10909 ROZZELLES FERRY RD CHARLOTTE, NC 28214 USA Description: Landtec Gas Analyzer Model: GEM5000 Serial Number: G506134 Accredited Results: Certified Gas 5.0 15.0 50.0 Certified• G 5.0 15.0 50.0 Methane CH4 Instrument Read 4..8 14.8 48.9 Carbon Dioxide 4.9 14.8 50.4 Certificate Number: G506134_9/42345 0.42 0.66 1.03 0.43 0.71 1.19 Gas cylinders are traceable and details can be provided if requested. CH4, CO2 readings recorded at: 32.2 °C/89.9 T Barometric Pressure: 6985"Hg/29.08 "Hg 02 readings recorded at: 22.1 °C/71.8 °F Method of Test : The analyzer is calibrated in a temperature controlled chamber using a series of reference gases, in compliance with procedure ISP17. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately95%. The uncertainty evaluation has been carried out in accordance with NISI requirements_ The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System of Units (SI). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. Calibration instance: 112 IGC instance: 112 Page I of2l LP015LNANIST-1 I cauw:;u „ Date Of Calibration: 16-Aug-2021 No. 66916 Certificate Number: G506134 9/42345 Non Accredited results: Pressure Transducers inches of water column Transducer Certified ll,nw,j Static Reading (how) Certified Hi h 0" ( g) Rea ding[Highj Differential 0" Accurary Ott 40.08" 0 01, q 2.0" tl 4.00" 0.7" Barometer mbar Reference 0985 mbar / 29.08 "!fig lnstrumpnr As re ceived gas check readings: �~ �eriltled Gas 5.0 15.0 Methane 0985 mbar / 29. 4.8 14.9 49.6 iced has Carbon Dioxide CO2 5.0 h. 15.0 5.1 50.0 15.0 ' - ' � --v uas readings recorded at: As received Barometric Pressure recorded at: 22.1 °C/g1,8 of 1 As received gas check readings are only recorded if the instrument is received in a orking condition. Whe •e the instrument is received damaged no reading can be taken. �9 Date o ° Issue : 17 Aug 2021 ! Approved By Signatory .I r Thakrah Alshaaban Laboratory Inspection The calibration results published in this certif cite were obtafnea using equlpmentca The (: b Certification only applies to re sults shown. This certificate may not be reproduced other than in full, except with the prior written a gable of producing results that are traceable through NiSTrp the international System of Calibrati• �n Instance: 112 IGC Instance: 112 pproval of the issuing laboratory. Page 2 of2 i LP015LNANIST-I. I CERTIFICATE OF CONFORMANCE Issued BY: QED Environmental Systems Inc. Services Facility Date of Calibration: 2022_-08-13 Certificate Number: 01-1' 846_21RH-47960_20210813. Ol.pdf Customer Name: EASTERN SOLUTIONS LLC 10909 ROZZELLES FERRY RD CHARLOTTE, NC 28214 US Description: Temp Probe Model: 5KTP Serial Number: 01-11846 Test Criteria: �� -- -'— --- t5-F @ 40`F Temperature Reading Recoded At: 40.1°F Test Criteria: ±5°F @ 160°F Temperature Reading Recoded At: 157.7-F Test Criteria: y5'F ;W 212,E Temperature Reading Recoded At: 210.2`F Calibration Pass: Thakrah Alshaaban Reported readings are within the manufacturer's specifications. i service@gederv.com http://wwvv.geder.v.com, QED Environmental Systems, Inc, 800-624-2026 / 734-995-2547 x 575 / Fax 734-995-1170 QED Environmental Scysterjs ;roc. 2355 BrShop Circe :lest DextEr. `�,, 4g1S i 0-'V lVQEDEN%✓.00M 0 800-624.2026 734.995.2547 METHANE Lot: 304-402201441-1 HIGH EXp: 9/21/2025 METHANE Lot: 304-401985911-1 LOW EXp; 12/15/2024 OXYGEN Lot: 251253 HIGH EXp; 6/30/2024 arbo F'lt n er Saturation {CH4} CALIBRATION LOG LANDTEC - GEM 5000+ OXYGEN Lot: 304-401983749-1 LOW EXp: 12/15/2024 CARBON Lot: 304-401979954-1 MONOXIDE EXp: 12/7/2024 HYDROGEN Lot: 304-402227939-1 SULFIDE EXp: 9/17/2023 I Ion: PASS Gas Calibration Cheek Performed at Room Temperature SENSOR CH4 (%) Initial Readin CALdin Tolerance CO m 0.0 ORo +/- 0.5% Comments H2S mj 0.0 0.0 0.0 H2(%) 20 0.0 +/-5 m 2.0 +/- 1.5% SENSOR _ Initial Readin CAL Readin Tolerance 47.9 - - --- Comments 02(% 34.5 0.0 35.0 +/- 1.5% SENSOR CH4 % Initial Readin CAL Readin Tolerance CO2 % 10.4 10.0 +/- 0.5% Comments 10.3 SENSOR 42 % Initial Readin CAL Readin Tolerance 20.4 Comments20.9 +/- 0.5% SENSOR 02 {%] Initial Readin CAL Readin Tolerance 4.0 4 0 Comments +/- 0.5% SENSOR CO { m Initial Readin CAL Readin Tolerance 995 1000 Comments m SENSOR H2S(m) nitiaReadi n CAL Readin Tolerance 191 200 +/- 10 Dom Corrlments Signature: fz Date: 10/8/2021 EASTERN SOLUTIONS, LLC (803)746-5180 PACKING LIST GEM S000 ES #: r WS Date: !Q —1?-7,;L/ Standard Items Prepared QC Chec GEM 5000 Calibration Gases 6-00 CH4 High �� psi Manual / CH, Low psi Factory Calibration Cert ,/ � 100 —'---- —rY— Oz Low "l psi ----- Quick Reference GuideQ OZ High �� psi Vinyl Tubing � � p (Blue, Yellow, Clear) - - CO psi Barbs (5) 6 6d H2S psi Water Trap '� - Spare Water Trap Charcoal Filter Charger Valves (Male/ Female) Temperature Probe Calibration Gasses (6) Calibration Log f Calibration Sticker Prepared By-74P QC Check: A4 Date: