HomeMy WebLinkAbout6301_MooreCounty_MSWLF_CDLF_Dec2021LFG_FID1628685_20220105ENR USE ONLY: []Paper Report ❑Electronic Data - Email CD data loaded: Yes / No Doc/Event #:
c DENR Environmental Monitoring
Division of Waste Management - Solid Waste Reporting Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
Prepare one form for each individually monitored unit.
Please type or print legibly.
Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification
must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing
condition, etc.).
• Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits.
Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the
facility (NCAC 13B .1629 (4)(a)(i).
Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste
Section, 1646 Mail Service Center, Raleigh, NC 27699-1646.
Solid Waste Monitoring Data Submittal Information
Name of entity submitting data (laboratory, consultant, facility owner):
S&ME, Inc. (on behalf of Moore County)
Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address:
Name: Edmund Q.B. Henriques Phone: 336-288-7180
E-mail: ehenriques@smeinc.com
NC Landfill Rule: Actual sampling dates (e.g.,
Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006)
Moore County Landfill 456 Turning Leaf Way, Aberdeen, NC 63-01 .0500 December 17,2021
Environmental Status: (Check all that apply)
❑ Initial/Background Monitoring x� Detection Monitoring ❑ Assessment Monitoring Corrective Action
of data submitted: (Check all that apply)
Groundwater monitoring data from monitoring wells �x
Groundwater monitoring data from private water supply wells ❑
Leachate monitoring data ❑
Surface water monitoring data
Methane gas monitoring data
Corrective action data (specify)
Other(specify)
Notification attached?
e No. No groundwater or surface water standards were exceeded.
Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water
monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and
preliminary analysis of the cause and significance of any concentration.
x] Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample
values and explosive methane gas limits.
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct.
Furthermore, 1 have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas
levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
Edmund Q.B. Henriques, PG Senior Geologist, S&ME Inc. 336-312-3330
Facility Representative Name
Signature
Title (Area Code) Teleph
8646 W. Market Street, Suite 105, Greensboro NC 27409
Facility Representative Address
F-0176
1 /5/2021 Affix
Date
Geologist Seal
41
5 A
ps`�r
m 8 b3
r7lij Z _
NC PE Firm License Number (if applicable effective May 1, 2009)
0.,,,!•--,4 aronnn
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such. these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Moore County Landfill PennitNumber: 63-01
Sampling Date: December 17, 2021 NC Landfill Rule (.0500 or.1600): 0.0500
Sample Collector Name & Position: Ed Henriques / Senior Geologist, S&ME, Inc.
Gas Meter Type & Serial Number: GEM 5000 / SN G507243 Gas Meter Calibration Date: 1 1 /4/2021
Field Calibration Date & Time: 12/16/2021
Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 04/2025
Gas Meter Pump Rate: 683 cc/min
Ambient Air Temperature: 65 Barometric Pressure (in. or mmHg): 29.67" Weather Conditions: Sun
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See
individual permit conditions and/or Facility LFG monitoring plan.
Location or
LFG Well ID
S ample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
%LEL
Stabilized
%LEL
% CH4
(volume)
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
GP-9
60
1249
120
0
0
0.0
20.0
0.7
0
Property Boundary Monitoring Point
G P 10 R
60
1301
120
0
0
0.0
19.5
1.3
0
Property Boundary Monitoring Point
GP-1 1
60
1306
120
0
0
0.0
17.7
3.7
0
Property Boundary Monitoring Point
GP-12
60
1329
120
0
0
0.0
20.6
0.2
O
Property Boundary Monitoring Point
GP-13R
60
1512
120
0
0
0.0
20.1
1.1
0
Property Boundary Monitoring Point
GP-14R
60
1504
120
0
0
0.0
17.7
2.6
0
Property Boundary Monitoring Point
GP-15R
60
1458
120
0
0
0.0
19.6
1.5
0
Property Boundary Monitoring Point
GP-16
60
1448
120
0
0
0.0 112.3
8.4
0
Property Boundary Monitoring Point
GP-1 7
60
1436
120
0
0
0.0
2.3
15.0
0
Property Boundary Monitoring Point
GP-18
60
1358
180
> 100
> 100
27.8
0.2
28.0
0
Property Boundary Monitoring Point
GP-1 9
60
1342
120
0
0
0.0
18.0
4.2
0
Property Boundary Monitoring Point
NOTE: If needed. attach additional data forms to include additional LFG monitoring data locations for the facility.
ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or certification including the possibility of a fine and imprisonment.
A".A Senior Geologist / S&ME, Inc.
SIGNATURE TITLE
Revised -March 6, 2017
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Moore County Landfill Permit Number: 63-01
Sampling Date: December 17, 2021 NC Landfill Rule (.0500 or.1600): 0.0500
Sample Collector Name & Position: Ed Henriques / Senior Geologist, S&ME, Inc.
Gas Meter Type & Serial Number: GEM 5000 / SN G5O7243
Field Calibration Date & Time: 12/16/2021
Gas Meter Calibration Date: 11 /4/2021
Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 04/2025
Gas Meter Pump Rate: 683 cc/min
Ambient Air Temperature: 65 Barometric Pressure (in. or mmHg): 29.67" Weather Conditions: Sunny
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location man or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See
individual permit conditions and/or Facility LFG monitoring plan.
Location or
LFG Well [D
S ample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
% LEL
Stabilized
% LEL
% CH4
(volume)
volume
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
M W-6
60
1335
120
> 100
> 100
13.8
8.4
13.9
0
not a compliance point
GV-33
60
1413
120
> 100
> 100
34.3
0.4
31.7
0
Passive vent, not a compliance point
GV-34
160
1406
120
> 100
> 100
46.6
0.2
35.3
0
Passive vent, not a compliance point
Scale House
60
1245
120
0
0
0.1
20.6
0.2
0
on -site structure
Maintenance Shop
60
1320
120
0
0
0.0
20.6
0.1
0
on -site structure
Transfer Station
60
1312
120
0
0
0.0
20.6
0.1
0
on -site structure
Blake Residence
60
1535
120
0
0
0.0
21.5
0.0
0
off -site structure
NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility.
ACT1ON LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or certification including the possibility of a fine and imprisonment.
r
Senior Geologist / S&ME, Inc.
SIGNATURE V TITLE
Revised — March 6, 2017
Table 1
Summary of 2020 & 2022 Methane Gas Readings
Moore County Landfill (Permit 63-01)
Moore County, North Carolina
S&ME Project No. 4358-20-043A
Location
Monitoring Point Type
Scale- house
ONSS
it
Maintenance
Shop
NSS
Transfer
Station
ONSS
Blake
Crawlspace
OFFSS
GP-9
PB
r
PB
--
footnote#2
r.
PB J$B
JJB
PBJJPB
See
fo.tnot
PB
See
footnote#2
PB
PB
See
footnote#2
PB
PBJJ
PB
See
-
- 15
GP 8
I
seeDate
PB
02/17/20
0.0%
0.0%
0.0%
0.0%
0.0%
18.7%
not installed
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
11.9%
28.1%
not installed
04/07/20
0.0%
0.0%
0.0%
0.0%
0.0%
32.2%
not installed
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.4%
23.6%
59.9%
not installed
09/15/20
0.1%
0.0%
0.0%
0.0%
0.1%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
0.0%
22.5%
0.0%
12/14/20
0.0%
0.0%
0.0%
0.1%
0.1%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.5%
9.6%
61.3%
0.0%
02/24/21
0.0%
0.0%
0.0%
NM
0.0%
abandoned
0.0%
1 0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.4%
28.7%
67.9%
0.0%
04/12/21
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
1 0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.2%
2.0%
21.8%
0.0%
09/29/21
0.0%
0.0%
0.0%
0.0%
0.0%
1 abandoned
0.0%
1 0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.0%
19.5%
57.5%
0.0%
12/17/21
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
I 0.0%
13.8%
27.8%
0.0./
Notes:
Monitoring Point Types: PB = Property Boundary, ONSS = On Site Structure, OFFSS = Off -site Structure
Footnote#1 = MW-6 was replace by GP-19 as the property boundary compliance point. MW-6 is approximately 150 feet inside the property boundary and not a compliance point.
Footnote#2 = GP-10 was replaced by GP-10R, GP-13 replaced by GP-13R, GP-14 replaced by GP-14R, GP-15 replaced by GP-1511
Footnote#3 = Groundwater monitoring well MW-15 converted to gas monitoring point now identified as GP-18, which is a property boundary compliance point.
all measurements recorded in percent methane by volume
Lower explosive limit of methane gas: 5%
Upper explosive limit of methane gas: 15%
Data recorded prior to 9/15/20 obtained by Golder
not installed = Well not installed at the time of monitoring
Yellow highlight cells and values in bold print indicate methane percent by volume greater than or equal to 5% at property boundary monitoring point
Orange highlight cells and values in bold print indicate methane percent by volume greater than or equal to 1.25% inside structures.
T:\ENV\Pr.je \2020\4358-2 43A Moore County Routine LFG&WQ Monitoring\Phase 04-Quarterly Methane Monitoring 2021-2022\LFG Readings Tables and Char[s_IN PROGREss.A. 1/4/2022
E RO I
QUIPEr I Ca
LANDTEC GEM 5000 Pfus
CALIBRATION DATA SHEET
Serial Number G S074Z-9-S
Date 1 ZI IE7/ZI Inspector
Time/Date Q _ Battery Level
Memory Cleared Q)" CAOS4i Pump Faults
Y'OZ
Gas Alarms: CH, = 100.0% C)V-aL
CO2 = 100.0% r))CpSj_ = 22.0% C�
Zero Transducers Pump Flow Rate
b��� ^`i n vacuum Tested To 80" H2O
Calibration Ch
ck (Performed at Room Temperature)
Calibration Gas Calibration Gas Lot
Concentration
Number Expiration Reading Accuracy'
Pure N2 i Rca�o i
High CH, S��0
High CO2 35y1, 14
Low CH, 1 scri L2
Low CO, IS°10
Low 02 4yi. 13()
Z'p 1 20215 ITVP-7o
0
2%b 2-6 SO. 1-6 t2/o
2 2M2h 35 , 09? = 2%
�7 ^
L422 Zm2S 1 �. � t o t 2%
2ON
(2)L S 2%
High 02 20.9%
NIA N/A 21 .270
CO C5!Dm
H2S p�m
as t 10%
10%
'Accuracy depends upon calibration range, I5 % FS range
or CHa & CO2, 0-5% volume furor, 0/ FS for H,S, and 10% of reading for CO.
INSPECTOR'S
MAINTENANCE NOTES
II
I
EEI GEM 2000 Plus U F. m 01/12
No.66916
Date Of Calibration: 04-Nov-2021
Customer: Enviro Equipment Inc
11180 Downs, Rd Pinevill, NC 28134 USA
Description: Landtec Gas Analyzer
Model: GEM5000
Serial Number: G507243
Accredited Results:
Methane ICH41
Certificate Number: G507243_9/42945
Certified Gas %
Instrument Readin %
Uncertainty
5.0
15.0
50.0
4.9
14.9
49.1
0.42
0.66
1.03
Carbon Dioxide CO2
Certified Gas '/o
Instrument Readin %
Uncertainty%
5.0
15.1
50.0
4.8
14.8
50.2
0.43
0.71
1.19
Oxygen 02
Certified Gas %
Instrument Readin %
Uncertainty
20.9
21.0
0.25
Gas cylinders are traceable and details can be provided if
requested.
CH4, CO2 readings recorded at: 30.4 aC/86.7 "F Barometric Pressure: 0992 mbar/29.30 "Hg
02 readings recorded at: 21.6 `C/70.8 aF
Method of Test : The analyzer is calibrated in a temperature controlled chamber using a series of reference
gases, in compliance with procedure ISP17.
The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2,
providing a level of confidence of approximately 95%. The uncertainty evaluation has been carried out in accordance
with NIST requirements.
The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System of
Units (SI(. Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory.
Cahbmfioa lvsuvice 112 iGC lnsu im 112 Page 1 of 21 LPoISLNAMST-LI
&rjLA
mntare:m
No. 66916
Date Of Calibration: 04-Nov-2021
Non Accredited results:
Certificate Number: G5O7243_9/42945
Pressure Transducers'' inches of water column
Transducer Certified (Low) Reading (Low) Certified (High) Reading (High) Accuracy
Static
0"
0"
40"
39.87"
2.0"
Differential
0"
0"
4"
3.98"
0.711
Barometer (mbar)
- Reference
Instrument Reading
0992 mbar / 29.30 "Hg
0992 mbar / 29.30 "H
As received gas check readings:
Methane(CM)
Certified Gas %
Instrument Reading%
5.0
4.8
15.0
14.6
50.0
48.7
Carbon bioxide CO2
Certified Gas %
instrument Reading %
5.0
5.2
15.1
15.2
50.0
48.9
Oxygen 02
Certified Gas %
Instrument Reading
20.9
20.8
As received Gas readings recorded at: 30.4 °C/86.7 T
As received Barometric Pressure recorded at: 21.6 "C/70.8 °F
Date of Issue : 05 Nov 2021 Approved By Signatory
Kyle Racine
Laboratory Inspection
The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through MIST to the International System of
Units (51). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory.
CaDimb v Ivsunce: 112 IGC Insunce. 112 PaSe 2 of 2 I LP015LNANIST-I.I