HomeMy WebLinkAbout7401_INSP_20211206FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
UNIT TYPE:
Lined
MSWLF C&D
T&P YW
Collection Transfer Compost SLAS COUNTY: Pitt
Closed
MSWLF X HHW White
goods Incin T&P FIRM PERMIT NO.: 7401-MSWLF-
CDLF Tire T&P /
Collection Tire
Monofill Industrial
Landfill DEMO SDTF FILE TYPE: COMPLIANCE
Date of Inspection: 6 December 2021
FACILITY NAME AND ADDRESS:
Pitt County MSW Landfill
3025 Landfill Road
Greenville, NC 27834
GPS COORDINATES: N: 35.5962389 E: -077.4382472
FACILITY CONTACT NAME AND PHONE NUMBER:
John Demary
252.902.3355
FACILITY CONTACT ADDRESS:
Pitt County Solid Waste Department
3025 Landfill Road
Greenville, NC 27834
Attn: John W Demary
E-mail: john.demary@pittcountync.gov.
PARTICIPANTS:
John Demary; Pitt County Solid Waste
Ray Williams; NCDEQ-Solid Waste
STATUS OF PERMIT:
Closed MSWLF under Subtitle D
PURPOSE OF SITE VISIT:
Partial Facility Compliance Inspection without records review.
STATUS OF PAST NOTED VIOLATIONS:
None applicable
OBSERVED VIOLATIONS:
No violations were observed during this Facility Compliance Inspection. Please see the ADDITIONAL
COMMMENTS section below.
ADDITIONAL COMMENTS:
1) This Facility is a closed Municipal Solid Waste (MSW) Landfill.
2) The Facility is secured by means of a locked gate at the Facility entrance. The gate was open upon my arrival
and attendants were on site during this Facility Compliance Inspection.
3) The Facility access road is of all-weather construction and is being maintained in overall good condition.
4) Facility monitoring wells were reviewed. All reviewed wells were readily accessible, clear of brush,
properly labeled, and secured.
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
7401_INSP_20211206
Page 2 of 4
5) Overall, this Facility has a well-established cover crop of native warm season grasses.
6) The landfill cover crop is mowed throughout the year as needed.
7) Some small trees and other woody vegetation were observed growing around some of the surface
water outfalls. *Please remove all woody/brushy vegetation from the landfill. Moving forward, these
areas should be included in your routine landfill cover crop mowing/maintenance schedule.
8) Filling, grading, and seeding operations have been completed on the northern outside slope of the
landfill. The majority of the area included in this repair project has a healthy cover crop established,
however, some of the repaired areas are lacking a groundcover sufficient to prevent erosion of the
landfill cap system. *Please ensure all newly filled and graded areas are seeded and mulched/matted
to establish a groundcover suitable to prevent erosion in a timely manner. Any eroded areas should
be repaired prior to seeding.
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
7401_INSP_20211206
Page 3 of 4
9) Erosion control measures in the repair project area were in place and appear to be functioning properly.
10) Three areas of seeping leachate were observed during this Facility Compliance Inspection.; two were located
at/near the toe of the northern outsides slope and one near the western facing inner “elbow” of the transition
from the first to the second lift (please see the aerial photo on the final page of this report for the approximate
locations). No leachate was observed leaving the permitted landfill disposal boundary. *Withing thirty days of
receipt of this Facility Compliance Inspection Report, please repair the landfill cap system in all seeping
areas. The repaired areas should be graded at a slope not greater than 3:1, seeded, and mulched to establish a
groundcover suitable to prevent erosion of your landfill cap system. Please monitor all repaired areas for
continued seeping. Any areas where leachate continues to seep should be addressed promptly to prevent the
release of leachate outside the permitted disposal boundary.
11) This Facility currently manages landfill gas (LFG) through an on-site LFG-to-energy plant.
12) No off-site erosion was observed around the perimeter of the Facility during this Facility Compliance
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
7401_INSP_20211206
Page 4 of 4
Inspection.
13) No areas of ponding or standing water were observed during this Facility Compliance Inspection.
14) *Corrective measures are required as a result of this Facility Compliance Inspection.
Please contact me if you have any questions or concerns regarding this Facility Compliance Inspection Report.
Ray Williams; Environmental Senior Specialist Phone: 252.948.3955 E-mail: ray.williams@ncdenr.gov
Regional Representative
Delivered on: 8 December 2021 by X Electronic delivery US Mail Certified No. [ _]
cc: Andrew Hammonds; Eastern District Supervisor/SWS: andrew.hammonds@ncdenr.gov
C: \2021\Pitt\Facilities\74-01\Inspections\7401_INSP_20211206
NCDEQ DWM Laserfiche Online Document Management System:
https://edocs.deq.nc.gov/WasteManagement/Browse.aspx?id=2034&dbid=0&repo=WasteManagement
Go Green! Thank you for helping NCDEQ be environmentally responsible.
Approximate locations of three areas noted as seeping leachate outlined in red.