Loading...
HomeMy WebLinkAbout09066_Sonoco Flexible_SIR_2021.11.29 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 12/01/2021 9:31 AM I. Inspection Information Date & Time: 11/30/2021 12:03 PM Inspection Type: Drive-By Brownfields Staff: Carolyn Minnich, Joselyn Harriger, Kevin Slaughter Other Personnel: Stephanie Graham - DEQ, John King- Bell Partners, Regional Maintenance Manager Location: Lat: 35.208367791498276, Long: -80.86408721785767, Brownfields Inspection Report: Sonoco Flexible, 09066-05-060 11/30/2021 12:03 PM Page 2 of 6 II. Project Information Number: 09066-05-060 Name: Sonoco Flexible Address: 2203 Hawkins St City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Residential Structures on Property: Existing Structures Violation: Unknown Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: Observed the two repair areas, Cox Colvin VaporPin installation, and concrete placement (Photos 1-4). No attempt was made at repairing moisture barrier due to its condition and composition (visqueen) Summary: N/A Summary: Four-story, high density apartment complex Summary: N/A Brownfields Inspection Report: Sonoco Flexible, 09066-05-060 11/30/2021 12:03 PM Page 3 of 6 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A Based on prior indoor air sampling in the vicinity of the two sewer line repair excavations, there did not appear to be a risk to the public. In addition, both repair areas were being filled with concrete flush with the floor slab during the site inspection. Brownfields Inspection Report: Sonoco Flexible, 09066-05-060 11/30/2021 12:03 PM Page 4 of 6 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Sewer line excavation on lower level ready for concrete repair. VaporPin insert (black rod), and new PVC sewer line cleanout visible within repair area. Arrived on-site as the two sewer line repair excavations were being covered with fresh concrete following backfilling and installation of a vapor pin insert within each excavation for future sub-slab sampling. Brownfields Inspection Report: Sonoco Flexible, 09066-05-060 11/30/2021 12:03 PM Page 5 of 6 Photo 2: Upper level concrete repair work being performed. Photo 3: VaporPin Insert threaded rod sticking out of concrete repair area. Brownfields Inspection Report: Sonoco Flexible, 09066-05-060 11/30/2021 12:03 PM Page 6 of 6 Photo 4: Lower level excavation ready for concrete repair.