Loading...
HomeMy WebLinkAbout4116_Guilford_WI_GFL_HighPoint_CDLF_LFG_FID1625074_202111234 GREEN FOR LIFE e n v i r o n m e n t a I November 23, 2021 Ms. Jaclynne Drummond, Hydrogeologist Department of Environmental Quality, Division of Waste Management, Solid Waste Section 2090 US Highway 70 Swannanoa, North Carolina 28778 jaclynne.drummond@ncdenr.gov RE: METHANE MONITORING RESULTS — NOVEMBER 2021 MONTHLY EVENT WI HIGH POINT CONSTRUCTION AND DEMOLITION LANDFILL AND RECLAMATION FACILITY, PERMIT NO. 41-16 Dear Ms. Drummond, WI High Point Landfill, LLC, is submitting the enclosed monthly methane monitoring results for the November 2021 monthly methane monitoring event at the above -referenced facility. If you have any questions, please contact me at (724) 244-9511. Sincerely, WI High Point Landfill, LLC Joseph Santangelo Regional Environmental Compliance Manager Enclosure C: Dusty Reedy, PG, Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, North Carolina, 27407, 336-852-4903, dreedy@golder.com Travis Hitchcock, 3301 Benson Drive, Raleigh, North Carolina, 27609. (travis.hitchcock@gflenv.com), (letter only). Bryan Wuester, Regional Landfill Manager, 7434 Roseboro Highway, Roseboro, Sampson County, North Carolina 28382, Bryan.Wuester@gflenv.com Seth Heath, General Manager,5830 Riverdale Drive, Jamestown, North Carolina 27282, seth.heath@gflenv.com, 336-886-3560 1236 Elon Place High Point NC, 27263 Tel.:336-668-3712 Fax:336-482-3061 gflenv.com I hNR USE ONLY ❑Paper Report f]Electronic Data - Email CD data ioaded: Yes J No DoGEvent W. NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute i 32 1, As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132.6). Instructions: • Prepare one form for oath Individually monitored unit. Please type or print legibly. Attach a notification table with values that attaln or exceed NC 2L groundwater standards or NG 29 surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source. pre-existing condition, etc,). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits, Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). • Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit. NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646, Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Golder Associates NC, Inc. on behalf of WI High Point C&D Landfill Contact for questions about data formatting, Include data preparer's name, telephone number and E-mail address: Name: David Y. Reedy 11, PG Phone: 336.852-4903 E-mail: dayid reedyQgolder.com NC Landfill Rule: Facility name: Facility Address' Facility Permit # (.0500 or .1600) WI High Point C&D Landfill 5830 Riverdale Drive 41-16 .500 Jamestown. NC 27262 Actual sampling dates (e,g„ October 20-24, 20D6) Environmental Status: (Check all that apply) LJ initial/Background Monitoring ❑ Detection Monitoring Q Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells 7 Methane gas monitoring data Groundwater monitoring data from private water supply wells Correclive action data (specify) Leachate monitoring data Other(speciN) Surface water monitoring data Notification attached? No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values. NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any Concentration. x Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the Information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. David Y Reedy II. PG Senior Hydrogeologist 336-862-4903 Facility en tive N 11' Q Title (Area Code) Telephone Number ' -'23- 2 / Signature - Date Golder Associates NC, Inc., 513 Oak Branch Drive, Greensboro. NC 27407 Facility Representative Address PE C-2862; PG C-399 Affix NC Licensgpc [Qt essienal Geologist Seal x NC PE Firm License Number (if applicable effective May 1. 2009) Revised 612009 GOLDER MEMBER OF W5P November 23, 2021 Joseph Santangelo, Regional Environmental Compliance Manager GFL Environmental Inc. 3301 Benson Drive, Suite 601 Raleigh, North Carolina 27609 joseph.santangelo@gflenv.com Project No. 2013788121.703 METHANE MONITORING RESULTS — NOVEMBER MONTHLY EVENT FOR 2021 WI HIGH POINT CONSTRUCTION AND DEMOLITION LANDFILL AND RECLAMATION FACILITY, PERMIT NO. 41-16 Dear Joe, Attached are the results from the November 18, 2021, monthly methane monitoring at the above -referenced facility for your files. As shown on the attached Landfill Gas Monitoring Data Form, methane was detected at compliance monitoring point LFG-2A at a concentration above the lower explosive limit (LEL) during this monthly methane monitoring event. A Landfill Gas Remediation Plan (LFGRP) was submitted to the North Carolina Department of Environmental Quality (NC DEQ) by Smith+Gardner on July 26, 2021 and was approved by the NC DEQ on August 2, 2001. As proposed in the LFGRP, the installation of vent in the berm adjacent to LFG-2A and re -grading the area to promote better drainage began on July 23, 2001. Golder installed two additional vents were in the vicinity of LFG-2A on September 13, 2021. A Landfill Gas Remediation System Construction Record and Update Report was submitted to the NC DEQ on November 4, 2021, which proposed additional investigation of the exceedances at LFG-2A. The report was approved by the NC DEQ on November 8, 2021. If you have any questions or concerns, please contact us at 336 852-4903. Sincerely, Golder Associates NC, Inc. David "Dusty" Y. Reedy II, PG Senior Hydrogeologist Golder Associates NC, Inc. 5B Oak Branch Drive, Greensboro, North Carolina, USA 27407 `&-rJ,.,Q ­I0 Rachel P. Kirkman, PG Principal and Senior Consultant Engineering Lic. No. C-2862/Geology Lic. No. C-399 Golder Associates NC, Inc. is a licensed user of the Golder trademark, and an associated operating entity. T: +1 336 852-4903 F: +1 336 852-4904 Golder and the G logo are trademarks of Golder Associates Corporation. golder.com Joseph Santangelo, Regional Environmental Compliance Manager GFL Environmental Inc. Project No. 2013788121.703 November 23, 2021 CC: Seth Heath, General Manager,5830 Riverdale Drive, Jamestown, NC 27282, seth.heath@gflenv.com, 336-886-3560 Bryan Wuester, Regional Landfill Manager, GFL Environmental, 7434 Roseboro Highway, NC 28382, bryan.wuester@gflenv.com (Electronic Copy) Travis Hitchcock, Region Vice President, GFL Envrionmental, 3301 Benson Drive, Suite 601, Raleigh, NC, 27609, travis.hitchcock@gflenv.com. (Electronic Copy) Attachments: Landfill Gas Monitoring Data Form — November 18, 2021 Site Location Map Calibration Forms GOELDER NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Nodee. This forma and any hit ornoatron attached to it are "Public Records" as defined In NC GeneralSianar 132-1. As such, These documents are available for mspectron and earaminatian by any person upon request (NC General Statute 132-d). Facility Name: Waste Industries of High Point C&D Landfill Permit Number: 41-1 5 Sampling Date: 11 /18/2021 NC Landfill Rule (.0500 or.l 600): .0500 Sample Collector Name &Position: Darren Cox, Environmental Scientist II Gas Meter Type & Serial Number: GEM 5000 Field Calibration Date & Time: /18/20 00 Gas Meter Calibration Date; 02/12/2021 Field Calibration Gas Type (15l l5 or 35150): 15/15 Field Calibration Gas Canister Expiration Date: 10/29/2024 Gas Meter Pump Rate: 300 cc/min Ambient Air Temperature: _720F _Barometric Pressure (in. or mm 1lg): 29.17" Weather Conditions: Fair, winds SW19mph Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as bath % LEL and % CH4 by volume. Convert % CHa (by volume) to % LEL as follows; % methane (by volume)!20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may he required for Construction & Demolition Landfills (C'DLFs). See individual permit conditions andlor Facifil3! LFG monitoring plan. Location or LFG Well ID Sample Tube Purge 'rime of Day Time pumped (sec) Initial % LEL Stabilized °!o LEL %CH4 (volume) %02 (volume) %CO2 (volume) %Ii2S' (volume) NOTES Scalehouse 12:01 90 0.0 0.0 0.0 20.6 0.1 0.0 Maintenance 12:04 90 0.0 0.0 0.0 20.6 0.1 0.0 Break Room 12:07 90 0.0 0.0 0.0 20.5 0.1 0.0 LFG-1 12:18 90 0.0 0.0 0.0 20.3 0.5 0.0 Pressure: 0.00 LFG-2 12:24 90 0.0 0.0 0.1 20.0 1.0 0.0 LFG-2A 12:22 90 318 318 15.9 0.4 27.4 0.0 Pressure'. 0.00 LFG-3 12:11 90 1 0.0 0.0 0.0 16.4 5.8 0.0 Pressure; 0.00 LFG-4 12.14 90 0.0 0.0 0.0 20.3 0.3 0.0 Pressure; 0,00 LFG-5 12:37 90 0.0 0.0 0.0 17.6 3.6 0.0 Pressure:0,00 NOTE, tf needed. attach additional data forms to include additional LFG motntorrng data locallonsfor fhe facfllfy. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sukfide: >1 % by volume (inside structures) AND a4% by volume (at facility boundary) Certification To the best of my knowledge, the inrormation reported and statements made an this data submittal and attachments are true and correct. 1 am aware that there are significant penalties for making any false statement, representation, or ccrtiftc lading tat ibilit olf a fine and imprisonment. '/ f SIGNATURE TITLE Revised - March 6, 2017 •�: '0 0L 0�q 09 1110 :• ��- �;• INN X. LFG-2 EXCAVATION 2 I RECLAMATION LFG-4 \ \ FACILITY � \ � MW-1 S �-740F /j 77 Mw 0 101 O SCALE FEET NT WIHIGHPOINT LANDFILL, LLC 4 //coNsuLrnn* YYYY-MM-DD 2021-09-23 i PREPARED BPG G 0 L D E R / DESIGN DYR MEMBER OF WSP REVIEW DYR GOLDER ASSOCIATES NC, INC. APPROVED RPK 24 F�'ayu�ar'f&- • r - -� � - Q0, SITE LOCATION �'�`.tq`< L .. .. 6 O SITE LOCATION MAP LEGEND EXISTING 10' CONTOURS EXISTING 2' CONTOURS — — PROPERTY LINE STREAM / DRAINAGE FEATURE �F TREELINE EXISTING ROAD — — — — — PROPOSED OR EXISTING LIMITS OF WASTE - MW-3 MONITORING WELL LOCATION ❑ SW-1 SURFACE WATER MONITORING POINT LFG-1 LANDFILL GAS MONITORING WELL LOCATIONS ® BM-1 BENCH MARK SB-1 SEDIMENT BASIN 0 GAS VENT EXCAVATION NOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET 2. DRAWING BASED ON SITE PLAN PLAN PREPARED BY JOYCE ENGINEERING, INC DATED J U LY 7, 2004. 3. UPDATED TOPOGRAPHY IN VICINITY OF LANDFILL PROVIDED FROM AERIAL SURVEY PREPARED BY COOPER AERIAL SURVEY COMPANY, DATE JANUARY 6, 2021. PROJECT WI HIGH POINT CONSTRUCTION AND DEMOLITION DEBRIS LANDFILL AND RECLAMATION FACILITY GUILFORD COUNTY, NORTH CAROLINA TITLE METHANE MONITORING LOCATION MAP PROJECT No. Rev. DRAWING 2013788121 0 1 c i c L 0 Date Of Calibration: 12-Feb-2021 Customer: EON Products Inc PO BOX 443 5nellville, GA 30078 USA Description. Landtec Gas Analyzer Model. GEM5000 Serial Number., G502124 Accredited Results: PJL A c.,Wa"aa No. 66916 Mpthnnp fCHAI Certificate Number: G502124_9P Certified Gas 9b Instrument Reading % Uncertain % 5.0 4.9 0.42 15.0 14.9 0.66 50.0 49.3 1.03 Carbon Dioxide COS Certified Gas % Instrument Reading % Uncertainty9b 4.9' 4.8 0.43 15.0 14.7 0.71 50.0 50.0 1.19 Certified Gas 95 Instrument Reading % Uncertain % 20.9 21.0 0.25 Gas cylinders are traceable and details can be provided if requested. CH4, CO2 readings recorded at: 30.6 °C/87.1 I Barometric Pressure: 0993"Hg/29.31 "Hg 02 readings recorded at: 21.7 "C/71.0 "F Method of Test : The analyzer is calibrated in a temperature controlled chamber using a series of reference gases, in compliance with procedure ISP17. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. The uncertainty evaluation has been carried out in accc with MIST requirements. The calibration results published in this certificate were obtained Using equipment capable of producing results that are traceable through NISI to the International 5Yaem of Units (SI). Certification only applies to results shown. This certificate may not be reprpduced other than In full, except with the prior written approval of the issuing laboratory. Cabmaan insmcc: 108 [GC Imumee, 108 Page l d2 l LMISLNANIST•],I Instrument: Landtec Model: GEM 5000 Serial#: 19010 Calibration Standards Standard: 35°I° CO2 Lot#: 304-401957974-'Response: Standard: 50°�o CH4 Lot: 304 401957974.1 Response: Standard: Lot#: Response: Standard: Lot#: Response: Service Performed By: Kenny C Units perfornls wiLhin specifications: X Flow OK: X 35.0% 50.1 % Date: 11/16/2021 Battery 0IC: X Ambip—nt. Cnncl it lnns Temperature: 77F Relative Humidity: Comments: _-__-- 37% The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through MIST to the international System of Units (SI). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. ]EON PA BOX 443. Sliellville, Georgia 30078-0443 800-474-2490 770-978-9971 Flax: 770-978-8661. PRODUCTS INC.