HomeMy WebLinkAbout5103_JohnstonLF_well_20211112WELL CONSTRUCTION RECORD
This form can be used for single or multiple wells
For Internal Use ONLY:
1. Well Contractor Information:
James D. Barker
Well Contractor Name
3106-A
NC Well Contractor Certification Number
Quantex, Inc.
Company Name
2. Well Construction Permit #: NA
List all applicable well construction permits (i.e. County, State, Variance, etc)
3. Well Use (check well use):
Water Supply Well:
❑Agricultural
❑Geothemlal (Heating/Cooling Supply)
❑ lndustrial/Commercial
❑ Irrigation
Non -Water Supply Well:
El Aquifer Recharge
El Aquifer Storage and Recovery
❑Aquifer Test
❑Experimental Technology
❑Geothermal (Closed Loop)
❑Geothermal (Heating/Cooling
❑Municipal/Public
El Residential Water Supply (single)
❑Residential Water Supply (shared)
El Groundwater Remediation
❑ Salinity Barrier
❑ Stormwater Drainage
❑Subsidence Control
❑Tracer
❑Other (explain under #21 F
4. Date Well(s) Completed: 7/6/21 Well ID# MW6-1
5a. Well Location:
JCO Landfill NA
Facility/Owner Name Facility ID# (if applicable)
680 County Home Road, Smithfield, NC 27577
Physical Address, City, and Zip
Johnston
County
NA
Parcel Identification No. (PIN)
5b. Latitude and Longitude in degrees/minutes/seconds or decimal degrees:
(if well field, one lat/long is sufficient)
35.510170 N 78.426199 W
6. Is (are) the well(s): R Permanent or ❑Temporary
7. Is this a repair to an existing well: ❑Yes or ONo
If this is a repair, fill out known well construction information and explain the nature of the
repair under #21 remarks section or on the back of this form.
8. Number of wells constructed: One
For multiple injection or non -water supply wells ONLY with the same construction, you can
submit one form.
t
9. Total well depth below land surface: 5
For multiple wells list all depths if different (example- 3@200' and 2@100')
10. Static water level below top of casing: - 1 7.5'
If water level is above casing, use "+"
-Qn
11. Borehole diameter: UU
12. Well construction method: _
(i.e. auger, rotary, cable, direct push, etc.)
(in.)
Auger
(ft.)
14. WATER ZONES
FROM
TO
DESCRIPTION
17.5 rt•
18 rt•
Blueish Grey Clayey SILT
rt.
rt.
15. OUTER CASING for multi -cased wells OR LINER if a licable
FROM
TO
DIAMETER
THICKNESS
MATERIAL
0 ft.
1 10 ft.
2 in-
Sch 40
PVC
16. INNER CASING OR TUBING eother a] closed -loop)
FROM
TO
DIAMETER
THICKNESS
MATERIAL
ft.
ft.
in.
ft
ft
in.
17. SCREEN
FROM
TO
DIAMETER
SLOT SIZE
THICKNESS
MATERIAL
10 ft'
255 ft'
2 in.
0.010
Sch 40
PVC
ft.
ft.
in.
18. GROUT
FROM
TO
MATERIAL
EMPLACEMENT METHOD & AMOUNT
0 rt.
6 rt.
neat cement
Pour 110 lbs. neat cement
6 rt.
8 rt.
bentonite
Pour 30 Ibs 1/4" Bent. Pellets
rt.
rt.
19. SAND/GRAVEL PACK (if applicable)
FROM
TO
MATERIAL
EMPLACEMENT METHOD
8 rt
20 rt
#2 sand
Pour
rt.
rt.
20. DRILLING LOG attach additional sheets if necessary)
FROM
TO
DESCRIPTION color, hardness, soil/rock type, grain size, etc.)
0 rt.
5 rt.
Light Brown SAND
5 rt.
10 rt•
Reddish Orange Clayey SILT
10 rt.
15 rt.
Yellow SILT
15 ft-
25 ft.
Blueish Grey Clayey SILT
rt.
rt.
ft.
ft.
rt.
rt.
21. REMARKS
22. Certi c 'on: j*
&..-, 7/9/21
Signature of ertified Well Contractor Date
By signing this form, I hereby certify that the well(s) was (were) constructed in accordance
with 15A NCAC 02C .0100 or 15A NCAC 02C .0200 Well Construction Standards and that a
copy of this record has been provided to the well owner.
23. Site diagram or additional well details:
You may use the back of this page to provide additional well site details or well
construction details. You may also attach additional pages if necessary.
SUBMITTAL INSTUCTIONS
24a. For All Wells: Submit this form within 30 days of completion of well
construction to the following:
Division of Water Quality, Information Processing Unit,
1617 Mail Service Center, Raleigh, NC 27699-1617
24b. For Iniection Wells: In addition to sending the form to the address in 24a
above, also submit a copy of this form within 30 days of completion of well
construction to the following:
Division of Water Quality, Underground Injection Control Program,
FOR WATER SUPPLY WELLS ONLY: 1636 Mail Service Center, Raleigh, NC 27699-1636
13a. Yield (gpm) Method of test: 24c. For Water Supply & Injection Wells: In addition to sending the form to
the address(es) above, also submit one copy of this form within 30 days of
13b. Disinfection type: Amount: completion of well construction to the county health department of the county
where constructed.
Form GW-1 North Carolina Department of Environment and Natural Resources - Division of Water Quality Revised Jan. 2013
SMITH GARDNER
Client:
-_
ProjectNumbeonCouJohnston-20-2 Logged8y: SCR
BORING ID: MW-6-1
Site Location: 680 County Home Rd, Smithfield, NC 27577
Boring Location: 35°31'07.5"N 78°26'07.8"W
Sheet: 1 of 1
Drilling Method: Hollow Stem Augers
Monitoring Well Installed: YES
Sample T pe s : NA __FBoring
Diameter: 4.25 inches
Screened Interval: 10-25'
Weather: Partly Cloudy, Hot
Ground Elevation:
Date Started: 07/06/21
Depth of Boring: 25'
Drilling Contractor: Quantex Environmental
TOC Elevation:
Date Finished: 07/06/21
Water Level: NA
x
p
E
Q
o
o
iij-
rn
MATERIALS: Color, size, range, MAIN COMPONENT, minor
o
m
cn o
-0
cc
Ci
component(s), moisture content, structure, angularity, maximum
Monitoring Well Construction
o
a
C
o
O
o
Z)
grain size, odor, and Geologic Unit (If Known)
Details
E
co
J
m
l6
(n
J
N
_
1
2
3
NA
no
0-5' Light brown/ Tan, Dry, SILTY SAND
4
5
6
7
8
NA
no
5-10, Orange/red, Moist, SILTY CLAY
9
10
11
12
13
NA
no
10-15' Orange/red - Tan, Moist, SILTY CLAY
14
15
16
16-17' Increased drill rig chatter
17
18
NA
no
15-20' Tan, Moist, SILTY CLAY
19
20
21
22
NA
no
20-24' Tan, Moist, SILTY CLAY
23
24
25
25' Light Gray, Dry, SILT
NOTES:
Date
Time
Depth to groundwater while drilling
Checked by Date: