Loading...
HomeMy WebLinkAbout3902_Granville_Butner_MSWLF_LFGMonitoring_FID1623154_20211101GARRETTE / & MOORE Engineering for the Power and Waste Industries September 30, 2021 Ms. Jackie Drummond North Carolina Department of Environment and Natural Resources Division of Waste Management, Solid Waste Section 1646 Mail Service Center Raleigh, NC 27699-1614 RE: Landfill Gas Monitoring Report 3rd Quarter Sampling Event of 2021 Granville County — Butner Closed MSW Landfill Permit # 39-02 Dear Ms. Drummond: Attached please find the Landfill Gas Monitoring Log and Gas Probe Location Map for the third quarter monitoring event that occurred on September 30, 2021, at the Granville County Butner Landfill (Permit number 39-02) for inclusion in your records. Methane was not detected above the LEL in any monitored location during this event. Additionally, hydrogen sulfide was not detected in any monitored location during this event. Landfill gas monitoring will continue on a quarterly basis for the Butner Landfill. If you have any questions, please do not hesitate to call me at 919-792-1904. Sincerely, Garrett Sr Moore, Inc. r rai .Fortner, ~ Cc: Jason Falls, Granville County 1029 W. South Street, Raleigh, North Carolina 27603 • O: 919-792-1900 • F: 866-311-7206 DEN R USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 213 surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Garrett & Moore, Inc. (consultant) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Craia M. Fortner E-mail: cfortner@garrett-moore.com Phone: 919-815-4221 NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Butner Landfill State Road 1004 39-02 .1600 September 30, 2021 Butner, NC Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑ Detection Monitoring ❑X Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data Surface water monitoring data X Methane gas monitoring data Corrective action data (specify) Other(specify) Hydrogen sulfide gas Notification attached? eX No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑ Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Craig M. Fortner Professional Engineer 919-815-4221 ve Nyj]me (Print) e Title ' - 9/30/2021 Date 1029 W. South Street, Raleigh, NC 27603 Facility Representative Address C-2910 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 (Area Code) Telephone Number Affix NC Licensed/ Professional Geologist Seal IIIIli 11111 0.4 jy\ WO 1�k •°• + so 7 �s lieSEAL�yra —_ 029929 0, AGII�Iti; 0 .q� Soso'• M '����c 1.i �tF+�'����`` NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). FacilityName: Granville County - Butner Closed MSWLF Permit Number: 39-02 Sampling Date: September 30, 2021 NC Landfill Rule (.0500 or.1600): -1600 Sample Collector Name & Position: Craig M. Fortner, Professional Engineer Gas Meter Type & Serial Number: GEM5000 Field Calibration Date & Time: 9/30/2021; 1207 Gas Meter Calibration Date: 01 /18/2021 Field Calibration Gas Type (15115 or 35/50): 35/50 Field Calibration Gas Canister Expiration Date: 2/23 Gas Meter Pump Rate: 550cc/min Ambient Air Temperature: 74 Barometric Pressure (in. or mm Hg): 29.53 Weather Conditions: P. S u n ny Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) x 20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial off" LEL Stabilized % LEL % CH4 � volume � % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES GP-1 Y 1531 60 0.0 0.0 0.0 17.5 4.0 0 GP-2 Y 1537 60 0.0 0.0 0.0 3.5 21.1 0 GP-3 Y 1542 60 0.0 0.0 0.0 19.1 2.7 0 GP-4 Y 1553 60 53.1 80.0 4.0 4.5 21.1 0 GP-5 Y 1550 60 0.0 0.0 0.0 8.4 12.5 0 GP-6 Y 1547 60 0.0 0.0 0.0 17.5 2.8 0 Scalehous Not sampled, locked Shed Y 1512 60 0.0 0.0 0.0 21.2 0.0 0 NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification in luding the possibility of a fine and imprisonment. Professional Engineer SI�AATUA TITLE Revised - February 4, 2020 \ APPROXIMATE MW 5 \ \ LOCATION \I PROPERTY LINE _ \� GP-2 i SW-1 AGV AGV I\ \ APPROXIMATE\ / GV \ I ��YYYY-MW-4 LIMITS OF WASTE ` - G\ I I I \ I V / CREEK CENTERLINE) / ` I MW-3R SW-2 M . I MT2R \ \ Z J 0 Ai Jz I LEGENDLL J I- --- 0 / I \ I I I I \ \ \ �., _ 130 EXISTING 25' TOPOGRAPHIC CONTOUR z O �� \ EXISTING 5' TOPOGRAPHIC CONTOUR Q Z _ PROPERTY LINE J } APPROXIMATE LIMITS OF WASTE LLI z / zZ) EXISTING ROAD �— O MW-1R CENTERLINE OF STREAM D U \ / GROUNDWATER MONITORING WELL MW iR LOCATION AND IDENTIFICATION J GP-1 GAS PROBE LOCATION AND > ���IDENTIFICATION z � GV GAS VENT \ - O� SW-1 SURFACE WATER MONITORING POINT Gp-q � — / (NM) NOT MEASURED m / V 5 Jt APPROXIMATEGPE LIMITS OF WASTENOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 5 FEET 2. STATIC WATER LEVELS MEASURED ON 12/12112. 777 3. ELEVATION RELATIVE TO MEAN SEA LEVEL. GfRAPHIC SCALE 4. TOPOGRAPHIC CONTOURS SHOWN IN THIS MAP ARE BASED ON 50 .100 200 2007 DATA OBTAINED FROM NCDOT WEBSITE. _5. BOUNDARYSURVEYPROVIDEDBY BATEMAN CIVIL SURVEY (FEET) COMPANY DATED MARCH 15, 2013. v PROJECT NO. 660.1201.12 SCALE AS NOTED DRAWING NO. 1 0 w w