Loading...
HomeMy WebLinkAbout4407_ROSCANS_1998MEMO TO: I From: DATE: t / SUBJECT: ��•c STATf 4, North Carolina Department of Environment, Health, and Natural Resources - - printed on Recycled •�'�e Nay. cY P DRAFT OPERATIONS PLAN SMALL TYPE 2 COMPOSTING FACILITY WHITE OAK LANDFILL HAYWOOD COUNTY, NORTH CAROLINA October 2008 1. INTRODUCTION A. Purpose of Plan This operations plan has been developed for the proposed Small Type 2 Composting Facility located at the White Oak Landfill in Haywood County, North Carolina. This plan has been prepared in accordance with the requirements of the North Carolina Department of Environment, Health, and Natural Resources (DENR), . Division of Solid Waste Management, Solid Waste Rules (15A NCAC 13B). The purpose of this plan is to provide the owner and operator with a reference manual that includes necessary information, procedures, and applicable rules for properly operating the Composting Facility. All personnel involved with the management or supervision of operations at the facility will be required to review the Operations Plan and to maintain the facility in conformance with applicable requirements. A copy of the Operations Plan will be kept in the vicinity of the Composting Site at all times. B. Facility Location The Small Type 2 Composting Facility is located at the White Oak Landfill at 3898 Fines Creek Road, Waynesville, North Carolina 28785 and is operated by Haywood County. C. Service Area The Composting Facility will provide service for all of Haywood County. II. SITING REQUIREMENTS The proposed composting facility site is located south of the Phase 2 MSW cell and east of the Phase 1 Construction & Demolition cell. The location of the composting facility is illustrated on Figures 1 and 2 of the plans. Siting requirements are shown on the plans as well as described as follows: 1) The proposed Composting Facility is not located in the 100-year flood plain. 2) A 200-foot buffer is maintained between the composting facility and all residences. 3) A 100-foot buffer is maintained between the compositing facility and water supply wells. 4) A 50-foot buffer is maintained between all property lines and the composting facility. 5) A 25-foot minimum distance between compost areas and swales or berms will be maintained in order to allow for adequate access of fire- fighting equipment. 6) Haywood County has no zoning requirements for the composting site property. 7) Diversion beans and drainage ditches are designed to ensure that there will be no standing water in the composting area and there will be no off -site drainage problems and also to divert runoff from composting areas to sediment basins. 8) A 50-foot minimum buffer between perennial streams and the compost area will be maintained. 9) An all-weather gravel access road to the site will be kept passable at all times. 10) An erosion control permit submittal for the site is pending and a copy of the permit will be sent to NCDENR-DWM prior to commencing grading of the site. 11) Site screening of the composting site is not required. 12) Access to the composting facility is controlled by properly trained employees. 13) The site has diversion berms leading to a sediment basin. Both the ditches and the sediment basin can be utilized to control runoff from a potential fire. 14) An aerial photo illustrating the area within one-fourth mile of the site was submitted to NCDENR-DWM in the "White Oak Landfill MSWLF Site Study", dated November 4, 1998, III. OPERATIONS PROCEDURES A. Overview The Small Type 2 Composting Site will consist of an area of approximately 1.5 acres where composting will take place. The County intends to use culls from pre -consumer agricultural activities as a primary material source for the composting operation. Approximately 230 tons of agricultural culls per quarter will be available to the County for composting. Additionally, there are additional clean wood materials available at the landfill for composting as a result of the grinding operation, but these materials are typically 2 mulched and used prior to them becoming available for composting. For the twelve-month period from July 2006 through June 2007, the White Oak Landfill averaged 100 tons per month of wood and yard waste. Composted material will be utilized on site as a soil amendment for newly grassed areas. The rate of compost use will be determined as the compost is developed and the chemical constituency of the material is known. An analysis of compost taken from the Johnson Tomato Packing House in Canton was conducted. The Johnson Packing House compost will be similar in nature to compost produced at the White Oak Landfill. Additionally, analysis was conducted on the soils at the White Oak Landfill that will be used on intennediate slopes where compost will be used to establish vegetative cover. The results of the analyses and proposed compost application rates are included in Appendices 1 and 2 of this demonstration report submittal. Normal working hours for the Composting Site are 8:00 a.m. to 4:30 p.m., Monday through Friday and 8:00 a.m. to 12:00 p.m. on Saturday. The facility is closed on Sunday and the following holidays: New Year's Day, Independence Day, Thanksgiving Day, and Christmas Day. B. Personnel The facility is owned and operated by Haywood County. A minimum of two part-time staff employees is required for the daily operation of the Composting Site. These employees are properly trained in safety procedures and the inspection of incoming wastes. Training material published by the Solid Waste Association of North America (SWANA) is utilized for initial training of on -site personnel and for continuing education. The employees also direct and coordinate the movement of collection vehicles into and out of the Composting Site. C. Technical Operational Requirements On or before August I" of each year, the owner or operator shall report to the North Carolina Solid Waste Section, for the previous year beginning July I" and ending June 301h, the amount by weight of the solid waste that was received at the facility and disposed of in a landfill, incinerated, or converted to fuel. To the maximum extent practicable, such reports shall indicate by weight the county of origin of all solid waste. The owner or operator shall transmit a copy of the report to the county in which the facility is located and to each county from which waste originated. The following operational criteria shall be met at the Composting Site: 3 1) Small Type 2 Composting Facilities shall process or store less than 1,000 cubic yards of material for composting per quarter, and occupy less than two acres of land. 2) Type 2 composting facilities may receive pre -consumer meat -free food processing waste, vegetative agricultural waste, source separated paper or other source separated specialty wastes, which are low in pathogens and physical contaminants 3) Waste acceptable for a Type 1 facility may be composted at a Type 2 facility. Type 1 wastes include yard and garden waste, silvicultural waste, untreated and .unpainted wood waste or any. combination thereof. 4) Sludges may not included in a Type 2 Composting Facility. 5) Neither hazardous waste nor asbestos containing waste shall be accepted at the composting facility. 6) Household hazardous waste shall not be accepted at the composting facility. 7) The composting site shall not allow uncontrolled public access. 8) Compost shall be maintained at or above 131 degrees Fahrenheit for 3 days. The temperature of all compost produced shall be monitored sufficiently to ensure that the pathogen reduction criteria is met. 9) Nitrogen bearing wastes shall be incorporated as necessary to minimize odor and the migration of nutrients. 10) The finished compost shall meet the classification and distribution requirements outlined in Rule 15A NCAC 13B.1407 of the Solid Waste Regulations. D. Traffic Control Access to the Composting Site is controlled by properly trained employees who are located at the entrance of the landfill. As vehicles arrive at the Composting Site, site personnel will direct the driver to position the vehicle at the correct unloading location. When the contents of the vehicle are emptied, the driver is instructed to move the vehicle away from the Composting Site. E. Housekeeping, Litter, and Vector Control Incoming wastes will be transported to the Composting Site in covered or enclosed vehicles. Outgoing transfer trailers will also be covered or enclosed. Throughout the day and at the end of each working day, facility personnel will police the area for litter. Mosquitoes and rodents shall be controlled so as to protect the public health and welfare. 4 F. Fire Control In the event that a fire occurs, the local authorities will be notified immediately. The telephone numbers of local fire; police, ambulance and hospital facilities are posted in and around the facility at all times. Additionally, the White Oak Landfill facility keeps a water tank track on site at all times. In the event of a fire at the facility the NCDENR will be notified within 24 hours and written notification will be submitted within 15 days. G. Storm Water Management and Erosion Control An erosion control permit submittal is pending and a copy of the erosion control permit will be provided to the NCDENR-DWM upon receipt. Standard erosion control practices, such as a sediment basin, silt fencing, vegetating slopes, and diversion ditches will be utilized at the site. Runoff from the composting areas will be diverted to an existing sediment basin and a proposed sediment traps. H. Zoning Haywood County has no zoning requirements for the Scrap Tire Collection Site property. A detailed discussion of the zoning requirements for Haywood County is included in the "White Oak Landfill, MSWLF Site Study", dated November 4, 1998. 5 APPENDIX 4 SAMPLE COMPOSTING OPERATIONS DATA LOG JOHNSON TOMATO PACK NG HOUSE COMPOST INFORMATION SHEET ComuostinLy ®aerations Data Lo Windrow Date of Formation (if more than one windrow is formed on the same date, add A,B,C designator. Note location of windrows for future identification. Add weight of compost if known.) Materials used and source Date Temperature Noted. Date Temperature Noted Observations: Windrow Date of Foiniation (if more than one windrow is formed on the same date, add A,B,C designator. Note location of windrows for future identification. Add weight of compost if known.) Materials used and source Date Temperature Noted Observations: Date Temperature Noted Johnson Tomato Paeldng House Com ost Date of Transport to White Oak Landfill (each truckload should have data kept) Weight of Compost Approximate Volume of Compost (estimate length x width x depth of load of compost in truck) Observations (note materials in compost, condition of compost, location of disposal at WOLF. Does this material require additional composting?) Date of Transport to White Oak Landfill (each truckload should have data kept) Weight of Compost Approximate Volume of Compost (estimate length x width x depth of load of compost in truck) Observations (note materials in compost, condition of compost, location of disposal at WOLF. Does this material require additional composting?) 1 Due 0 MIZE . a] f NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES LAND QUALITY SECTION: Interchange Building, 59 Woodfin Place, Asheville, N.C. 28801(704) 251-6208 County Project: ON +G c��� IL 5�+� , '{:t: ti Z -t17J f. Case# c Project Location Person(s) Financially Responsibl Address M d .1 1. i_"ou , il-! 'tic 1 1. Pictures: Yes❑ NoET'�t� Number 2. Weather & soil conditions 3. Is site currently under Notice of Violation 7 Yes ❑� 4. Is the site in compliance with the S.P.C.A. and Rules ? 5. Violations: Prints ❑ Slides ❑ Video ❑ No []� Yes[] No[ If no check violations below. ❑ a. No approved plan, G. S. 113A-57 (4) and 15A N.C.A.C. 413.0007(c) �ailure to take all reasonable measures, 15A N.C.A.C.413.0005 ❑ b. Failure to follow approved plan, G.S. 113A-61.1 ❑ g. Inadequate buffer zone, G.S. 113A-57(1) ❑ c. Failure to submit revised plan, G.S. 113A-54.1(b) and ❑ It. Graded slopes and fills too steep, G.S. 113A-57(2) or 15A 15A N.C.A.C. 413.0018(a) N.C.A.C. 413.0024 (d) �d. Failure to provide adequate groundcover, G.S. 113A-57(3) and ❑ i. Unprotected exposed slopes, G.S. 113A-57(2) /15A N.C.A.C. 4B.0007 (b) or 15A N.C.A.C. 4B.0024 (e) ❑ j Failure to maintain erosion control measures, L� e. Insufficient measures to retain sediment on site, G.S. 113A-57(3) 15A N.C.A.C. 413.0013 ❑ k.Other (describe) 6. Has off -site sedimentation o urred since last inspection ? Yes +- Degree: Slight C Moderate ❑ Severe ❑ Remarks 7. Contact made with (Name)_ Inspection Report given to: Copy of inspection report to be sent to person(s) responsible: No ❑ Remarks Title (Name)-Tv,J, ea 1(--A_1T Z c. D re`Iv Other (Name) Tt'13 Date Sent 9. Corrective actions needed: L h.i'f i 1 c J'te1 J t ,"-e. zJf C v .n bfz tl r►7 if. -4 ✓' b. tiAl a/ .i' N L;� , J - c3I hTrtin,/. __ 9ccfe 10. Comments: Report by: Q�,� t y� �, , Others present Date of inspection I - q - q p• Time arriving on site Z 3,2 4 f9 Time leaving site / / . 3 ,-> 4 M ❑ PHONE CALL ❑ DISCUSSION FIELD TRIP ❑ CONFERENCE RECORD OF COMMUNICATION Cl OTHER (SPECIFY) (Record of item checked above) TO: \ Irt�lY T S Lome, FROM: DATE p � c�� �1vr1 �►'h }i'WSfm TIME ;1: 30- 5:3 o PM f5\ 1 -Su91ECi - C�Y►��1-sw; \n�cSl�S� i lan+ C.�u.�-vuv�j W% .c-frc7 •j-�-» T� 133 Cd 1� �jYxvyJ 2 ��-' � u-s,�.5 l tclsJlr�S u,�.w��>` L-�►-d �, tl SUMMARY OF COMMUNICATION I IS I t� c.Or�h\' hr\kA ba f�rrvvw reamn •d. Srsq� �vow.�P4:\1'prvl� e� 1�Rfx�i�lrnl�Ly 1; yS bn y�''�j J-R +r rrc� d b h 1-. S. R• t 33'8 6c-I ow 14-c, Nvj wpoil Co o 1n1 J t-�,dG t t I '� = coo rnZ,! I ANON 1� IU* 11 Su ►sor t��h ��<' 4Zh� QIWt1-sue Sct�'!Jh Rrro\ �enhic. tclWNrdS\'Dqy lAVC*Ku,,o 4Ac, WVIn l--,rh , akr.clwuc- !-o - f Wvur� C64"4)uAl 9► = �-?Fobr�TIto,r� o6xvvVv►•k iv'►� L a\stbf 11�Iroxi p,►� 1/z, h\'II- a,,,�� uF �oe- It S lti Myers Vv�•\rc nab' k-w.qi w4.--U e S ► -CA vrs Vir, M-t- bpi 6V ►m b 44 c e- v,;-jjA, - - c-, My. V1/L s u,.sSc cP 1'I-L P rr�h) cm, yn-� 0•p+1 u Z JDv de w1 r.5 I,a �� T-�was cawscicc 4%,,A +� c. ►mucl- bc, ►^c-wovtd-�roV.., +1 c, ru+�G� t,Ls►ho �Yuc 1<5 Or 4- S\v«A- WASviv.'s .Dammam c-om mwn" c vl�c� bw✓ I r-Fe-^dC-i �S Pry*-s '►v NODW clip"\L�v\ Glq- h LC�h�r���,a m.T 1 MV4 I�h�k l�r<a-c. . TA %\-r.w1 watt.,►-S 4-v, 0- wAs 1,DOYYIXW- ' -Eros ToWy\ t)� WJXjPe-5Vdle, Cc, J lq v w ki \ t+, j'1;\S *,At* *,e, yn ut d was r(' -mo uI4 S i tam- 1 �►d -t1;\ 5 ` ro c c-ss wa S Go rr r c.� �ci' z'� p+r✓o�. $ : t t� TA I D t1 1 j s) 57 - S noa-i •E+�cl� �1�..� �v'�.1� �' � p1'Ib>n c, u h Moir � � �� � � I. ' �► S�-L�' G.l I yt� vc� �0.� �cw. \rc vnlJJc t� Cy" wt-- ru nrA -- CONCLUSIONS, ACTION TAKEN OR REQUIRED Ta)"low T \r✓tAwreA io - -1.,, l u)uoc� L-c,�.�Ttll) Uh 1 1"1--1�q� i� JtYIt `�%ZT F1C,Y1►.�Lllt� I�li1tM5 WCvC 1CD- t WbY l�\yhamt� ` C115 G1lSS 1 bh� ft✓ .%- tU�s %iD )ece-�pp my f V rT 1'r kA p i �AC. I tm �- 0+ '$off 1/t f Y✓rt) Kcr1 1 Wo ocl Co. SA,) Wm• r- pY'c tbr 4*' m 1 IC, C1tTY n M jp\VL\k'� p'ce-55 ?,oprD 1D tit- i�►-� I �i l�6d host. , cts, tV4jbcd Yh Troi11FiZ ponpms CA (�Yrat� ha� 10-cer. �lzv�� �,, Y\t�h- r�cc� Sc��rtr� of Izhc1 1II ��tPssT-vim Lb+,3 -�eYlr. q vt� s ZVC. }v I<c? rcryuSZ �'ot.\lwc o,. p�rw.�c.1 vd �1 hS rRih \ 0-4 1� cT Vt, r�,�utse- LA;Ah. Ck, to Irdw t,r 44-prhSW +i e lo..A 1-° ►�01 p, ✓ r, ldVkt t'vwlh �- wee, fO 4-Ul 1 Yt+t.CL-, 'B'\ �' 4 b\ �, �; > MLLb (Ail) I ho be, - VyY -.-K C5 -t +,-r- Vzv\bG�1 Ata-5 ra or S&— 5kwtc, rd - INFORMATION COPIES TO: EPA Form 1300-6 (7-72) iq OIDTIC!) 42WO iel-OITA�')i 0,ObAMOD y ❑ Phone Call El Discussion El Field Trip ❑ Confe ed e RECORD COMMUNICATION ther (Specify) A w - 7 A (Record of item checked above) To: Ili From: ` 1 1s�� Date Time Subject Summary of Communication 1( e Q IM�.Tr11w�1 (/cc— yUv (CYcr(Q� Z CQ.".DI�I✓"� i L 7�r C'U�?;�a_} 1/l��r��JovIS G�d,�ia..�S. r2Kfr�J C��`-��z;-�1 �-- �z i}-�✓ s �� r A (LO , f _`— J i ✓c-` o n`e c e r _ he l? L � Cd !�)ln 1/ z ; 5 ems. � �O•-► h , e L �warJ�. 7crs S 0 pvc� r D bzr .�.- �%� / V�1S- � 1'7 z l V �.- �/ �1 ✓� ✓I l S Qi c /e!/1 f o✓�, S �� T��" (2+�%l�` v rM v S .���s 7 "c/ Conclusions, Action Taken or Required 2) 5jt u,C �",'--c� .c { ` - c-wc 'f %2c k . 4) Li 4,- AO r,,,f v,re /Y/ld 0/-Y ro INFORMATION COPIES EPA Form 130H (7.72) NC DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES Division of Solid Waste Management Solid Waste Section SOLID WASTE MANAGEMENT FACILITY EVALUATION REPORT Type of Facility Permit * Canty C� Name of Facility. , � �?n���� �, n'•ti �s KA,'_,U) �.1 i- t.-� `1( Location Date of Last Evaluation 1 Ci D I. Permit conditions Followed \ Yes No N/A A. specific Condition(s) Violated II. Operational Requirements Followed Yes No 15A N.C. Actin. Code 13H Section A. Specific Violation(s) by rxmber and letter. , III. Other Violations of Rule or Law IV. Evaluator's Comments V. Continuation Page Required? Yes No Receiving Signature r �= Evaluation Date Solid Waste Section { DEHNR 3793 (Part I White: Facility Part II Canary: Central Office Part III Pink: Regional Office) Solid Waste Section (Review 7/94) I I the G-S� I'MA-294 rm-pircz, that an eva-luvation progr.-am -be established for of' solid waste, mamcferent facilities on a stztewide basis. Me So,113, Waste Art a�d Solid Waste Mmqc-,jwxft lades cridif ied at I-EvA XCAC 13B, list reg"Arements, which must be INAlowed by solid waste Pzc a xel SN-0.1 ttlv e eallyttiorl form h -It-ion, re) �xxrf flhkny officia-I Pvalmgtions, 'Me furm sic n-A the I'Tqyxvrt. ty c NY &a- -.i txmtral off-koe file cxYpy c -lua f , f 1. e c cliy Itw-S -ko"r."at 'kwl, xwtaixwd in awcjrdarwith the W-t-oition axkd I- 'Is"41.41e oLSdLid Wa� ste -'--tion, Solid Wa.,ste Mmiagmmeit 6U4 of D',virunm6cawit, Healtli airl Natinal Resourves. JAMES B. HUNTJR. :. GOVERNOR r fa;i� ,;::VYAYNEMCDEYITT SECRETARY WILUAM L. MEYER DIRECTOR �f ! NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WASTE MANAGEMENT October 28, 1998 Mr. Joe Walker, Solid Waste Director Haywood County 278 Recycle Road Clyde, North Carolina 28721 RE: Request for an Alternative Daily Cover. Haywood County MSW Landfill - Permit Number 44-07 Dear Mr. Walker: The Solid Waste Section has reviewed your request to use an alternative daily cover consisting of ground painted or treated wood, sheetrock, and soil. Your proposal is hereby approved with the following conditions: Jim Patterson, Regional Waste Management Specialist, shall be notified prior to initial use. Mr. Patterson may be contacted in the Asheville Regional Office at (828) 251- 6208. 2. Your request to use an alternate daily cover at the referenced site will be for a 90-day demonstration period. This cover must comply with 15 NCAC .1626(2)(b) which requires an owner/operator to demonstrate that the alternative cover controls disease vectors, fires, odors, blowing litter, and scavenging without presenting a threat to human health and the environment. 3. To request additional or permanent approval, an operational plan including all methods, procedures, and practices involved, shall be developed and submitted for Section approval prior to the end of the 90-day demonstration period. Particular attention should be given to procedures related to potential landfill fires. Upon completion of the demonstration period and receipt of the operational plan, the permit will be amended to reflect the modification. if you have any additional questions, please contact me at (919) 733-0692 or Tim Jewett, Western Area Engineer, at (336) 771-4608 ext. 204. 7 Qa4m4z L z 11.. J es C. Coffey, Supervildr Solid Waste Section f' cc: Julian Foscue� Tim Jewett ``� y 3;7 Jim Patterson Raleigh Central Office - Haywood County Permit No. 44-07 401 OBERLIN ROAD, SUITE 150, RALEIGH, NC 27605 PHONE 919-733-4996 FAX 91 9-715-3605 AN EQUAL OPPORTUNITY /AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/10% POST -CONSUMER PAPER D HAYWOOD COUNTY SOLID WASTE MANAGEMENT October 16, 1998 Mr. Jim Coffey DEHNR�� lU` P. O. Box 27687 401 Oberlin Road '3 Raleibh, N. C. 27611-7687 Subject: Modification to Permit #44-07 Haywood County MSWLF Dear Mr. Coffey, Haywood County would like to obtain a permit modification for the White Oak Landfill - Permit #44-07. The modification for daily cover, Rule.1626(2)(a), would include a mixture of ground painted or treated wood, sheetrock and soil for daily cover. At the present time painted or treated wood and sheetrock is ground into a mulch like material and hauled to the White Oak Landfill. This material mixed with soil would make an excellent daily cover, and cut down on the amount of soil used. This alternative material should satisfy the Division requirements under Rule.1626 (2)(b). If you have any questions concerning this request, please contact me at 828-627-8042. Sincerely, Joe Walker Solid Waste D;'rector JW/lsc cc: Jack Horton, County Manager Jim Patterson, DSWM C Pilnled on recycled paper 278 RECYCLE ROAD • CLYDE, NC 28721 o Fax (704) 627-8137 Tel (704) 627-8042 NC DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES Division of Solid waste Kanagement Solid waste Section SOLID WASTE MANAGEIENT FACILITY EVALUATION REPORT Type of Facility Permit N County. Name of Facility -t t' Rl i , w ... A.. 11 11' , ? f ; > 1 ' Locati Date of Last Evaluation i 1. Permit Conditions Followed Yes No N/A A_ Specific Condition(s) Viol II. Operational Requirements Followed Yes No 15A N.C_ Admin. Code 138 Section A_ Specific Violations) by number and letter. r% )0 ► III_ Other Violations of Rule or Law IV. Evaluator's Convents V. Continuation Page Required? Yes No Receiving Signature Evaluation Date Solid Waste Section DEHNR 3793 (Part I White: Facility Part II Canary: Central office Part III Pink: Regional Office) Solid Waste Section (Review 7/94) I Ux C-L 3 130A-.294 that an proc be estab ad I.mm Ash- for the -les -h ,4X��I-MJM Of W-Ilid Waste facilit- on a stato�p-de tosis. rt e SkAic-I Waustxa- Markx1ement Act and Solid Waste Manaqemptt Rules codified at VA "NWAC 13B list mv.plremnts iAhhich. mmst be fall-cmed' 4y solid- waste. -b-- -3vction s1hall umplete the evaluation form each L off ir'dal (:,�Vahms,U—tm viti� fc),--m sha,111, be signed by tbe, V Lk '. Ralei�fll fxaltxal off 1cx-- f1le cXW Y II-T piholkl! Ru-11CWmA f-II-e- mpy -2: lb, -Ls fcKc).11 May m) n-kained in ac;cx)rxkv)op- with the Rcxmid Retention and Of t Solid SfUt4or Solid Was-te Managemnt' the �.�biwmt of Errviroymmit., Healtb and Natural Re--%ouxx.vii,,. 7 NC DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES Division of Solid Waste Management Solid Waste Section SOLID WASTE MANAGE ENT FACILITY EVALUATION REPORT Type of Faci l i ty' "I 6'yl ' ' Perm t # County i Name of Facility /.. ;' Fi`� �f �V fi }�r` Location 1 4 Date of Last Evaluation I. Permit Conditions Followed Yes No N/A A. Specific Condition(s) Vi II. Operational Requirements Followed Yes No 15A N.C. Achmin. Code 138 Section 11 U '4 L., A_ Specific Violation(s) by amber and Letter. III_ other Violations of Rule or Law IV. Evaluator's Comments_ � V. Continuation Page Required? Yes —4—Mo Receiving Signature Evaluation Date Solid Waste Section DEHNR 3793 (Part I White: Facility Part II Canary: Central Office Part III Pink: Regional Office) Solid Waste Section (Review 7/%) I 1,30,A.7-294 rMpulres tbet an, evalmation pmjr,7tm be established for the. <4x1ratim of ��-Jld vaste. inanagemert fricilities on a -statewide basis. The Solid Was-�. Manageawnt. Wlez codified at solid Waste ilimqc-mment. &�t and 1,1333 list, wbich mrst-, lx! -Call.crtred by s4)lid wdste awlete t aluation form each ;3ection �:neyixxNiel shall c he ev< f-h(nv ccwyticr official emaluations. Tbe foni sbill be siqned by re,-xeivirq the mport. -u- 14 fAca"J"Lity ac 'cligh (X-Iltxcll Offlcx-file OW hil;u, I i I c F- f-.icr-- f i ccW !,,Jri.s .,Lfauuq ma or IrKW in acxxxdwx�e with the. Recd Re-telition am-1 y I ceta 'k Ld W& c).i the S ),)-.I Sc�&,ian, Solid Was-te Plcmaqmverit &i i-runwriL, Health w-A blatimil, PF---,-xAlrce-s. .141 . NORTH CAROLINA DEPARTMENT OF FrWIRONMENT HEALTH, AND NATURAL RESOURCES LAND QUALITY SECTION: Interchange Building, 59 Woodfin Place, Asheville, N.C. 28801 (704) 251-6208 County ? .'� (Project: `i1 +G G2�i S�'�,'f�t: , •1�� T, J _Case#. Project Location r� C. / G L Person(s) Financially Address 1. Pictures: Yes ❑ 2. Weather & soil cor G� J '( . L No h Num)ber J J Prints ❑ Slides El Video ❑ tinnq t ; 3. Is site currently under Notice of Violation ? Yes No 4. Is the site in compliance with the S.P.C.A. and Rules ? Yes❑ No El"' If no check violations below. 5. Violations: ❑ a. No approved plan, G. S. 113A-57 (4) and 15A N.C.A.C. 413.0007(c) g f. Failure to take all reasonable measures, 15A N.C.A.C.413.0005 ❑ b. Failure to follow approved plan, G.S. 113A-61.1 ❑ g. Inadequate buffer zone, G.S. 113A-57(1) ❑ c. Failure to submit revised plan, G.S. i 13A-54.1(b) and ❑ h. Graded slopes and fills too steep, G.S. 113A-57(2) or 15A 15A N.C.A.C. 413.0018(a) N.C.A.C.4B.0024(d) ad. Failure to provide adequate groundcover, G.S. 113A-57(3) and ❑ i. Unprotected exposed slopes, G.S. 113A 57(2) /15A N.C.A.C. 413.0007 (b) or 15A N.C.A.C. 413.0024 (e) ❑ j Failure to maintain erosion control measures, L� e. Insufficient measures to retain sediment on site, G.S. 113A-57(3) 15A N.C.A.C. 413.0013 ❑ k.Other (describe) 6. Has off -site sedimentation o urred since last inspection ? Yes No ❑ Remarks Degree: Slight Moderate ❑ Severe ❑ Remarks 7. Contact made with (Nan Inspection Report given 8. Copy of inspection report to be sent to person(s) responsible: I Title (Name) -Pe , �� <<ia.l Z C 0 ! <<f Other (Name) 'Tr d, �'L� fTC�; �h / Date Sent f + Corrective actions needed: L �J_ s [ 1 J'��1% t ,�, t. >) t G v.� ✓� l +�? G v i �: �� Qrl � .(� N� � : �� C 447✓ignt.c 9r_ Report by:y Oe" e- y _Others present Date of inspection_ / — 6 _ q Q' Time arriving on site L 3 0 4 r% Time leaving site / / ' a M ca: s :W�; NC DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES Division of Solid baste Management Solid haste Section SOLID WASTE MANAGEMENT FACILITY EVALUATION REPORT Type of Facility. i •a t Permit # county. .Jar �'"'r:.�. Kane of Facility ' i�lUt `�!^, � :,.�? �^, eY,I" � ,�j`� Location s �� � ,� :� �' p!�4f,, �,�',�/��z f Date of Last Evaluation I. Permit Conditions Followed Yes No N/A A. Specific Condition(s) Violated II. Operational Requirements Followed Yes No 15A N.C. Admin. Code 138 Section A. Specific Violations) by number and letter. III. Other Violations of Rule or IV. Evaluator's Comments V. Continuation Page Required? Yes No Receiving Signature Evaluation Date Solid Waste Section DEHNR 3793 (Part I White: Facility Part II Canary: Central Office Part III Pink: Regional Office) Solid Waste Section (Review 7/94) f I'v&z,ti t GS 130A-29-4 r1j,101m; Uhlaxt an evaluation pxogram be established for the 01matitan of su-JAd waste imanagemwint. facilities an a statewide basis. The NOW W*a)-sto MMOWITKM Act and Solid Wasbe Managemnt Rules codified at 15A NrIC 13B list requirrment's pool he' follcmied by solid to -6:mn each i e:AL'Id fivst"C' S�--,XztACV'! PeKSAUnne-1 shall moplete No; millukical fhal Jy f:"r! t-Irvey official evaluatims. The form shall he signol b the rerran(s) rumiAml t1va roquar rePort - Axt I Mite: facility copy MA 11 Analy: Ralpeitg $1 Cealtral Off-ioe file (,XW fort DI Fink; Roginval office file oqwpy A 1SIX011 0KNI: This Am no, to rsizinxed in accmdfmoe with the Record Retcmtion and Oil sciledule of the Solid Waste Section, Solid Waste Management Di'vi,il-m. Oy" the Avartnent of Envixmunexit, Bealth and Natural Resources. I HAYWOOD COUNTY SOLID WASTE MANAGEMENT October 16, 1998 Mr. Jim Coffey DEHNR P. O. Box 27687 401 Oberlin Road Raleigh, N. C. 27611-7687 Subject: Modification to Permit #44-07 Haywood County MSWLF Dear Mr. Coffey, Haywood County would like to obtain a permit modification for the White Oak Landfill - Permit #44-07. The modification for daily cover, Rule.1626(2)(a), would include a mixture of ground painted or treated wood, sheetrock and soil for daily cover. At the present time painted or treated wood and sheetrock is ground into a mulch like material and hauled to the White Oak Landfill. This material mixed with soil would make an excellent daily cover, and cut down on the amount of soil used. This alternative material should satisfy the Division requirements under Rule.1626 (2)(b). If you have any questions concerning this request, please contact me at 828-627-8042. Sincerely, W l�-4— Joe Walker Solid Waste Director JWnsc cc: Jack Horton, County Manager Jim Patterson, DSWM ;r vrinied on recycled paper 278 RECYCLE ROAD • CLYDEr NC 28721 • Fax (704) 627-8137 Tel (704) 627-8042 1�` NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WASTE MANAGEMENT October 28, 1998 Mr. Joe Walker, Solid Waste Director f Haywood County 278 Recycle Road JAMES B. IiUNTJR GOVERNOR Clyde, North Carolina 28721 ..:;GO,i:,-+...-„j .7 RE: Request for an Alternative Daily Cover. Haywood County MSW Landfill - Permit Number 44-07 Dear Mr. Walker: The Solid Waste Section has reviewed your request to use an alternative daily cover consisting of ground painted or treated wood, sheetrock, and soil. Your proposal is hereby approved with the following conditions: 1. Jim Patterson, Regional Waste Management Specialist, shall be notified prior to initial use. Mr. Patterson may be contacted in the Asheville Regional Office at (828) 251- 6208. f 2. Your request to use an alternate daily cover at the referenced site will be for a 90-day demonstration period. This cover must comply with 15 NCAC .1626(2)(b) which requires an owner/operator to demonstrate that the alternative cover controls disease vectors, fires, odors, blowing litter, and scavenging without presenting a threat to human health and the environment. 3. To request additional or permanent approval, an operational plan including all methods, procedures, and practices involved, shall be developed and submitted for Section approval prior to the end of the 90-day demonstration period Particular attention should be given to procedures related to potential landfill fires. Upon completion of the demonstration period and receipt of the operational plan, the permit will be amended to reflect the modification. Fr If you have any additional questions, please contact me at (919) 733-0692 or Tim Jewett, c Western Area Engineer, at (336) 771-4608 ext. 204. Sincerely, N Ones C. Coffey, Supervi r Solid Waste Section Y :'1 cc: Julian Foscue 5 a 4 h Tim Jewett Jim Patterson Raleigh Central Office -Haywood County Permit No. 44-07 -? 401 OBERLIN ROAD, SUITE ISO, RALEIGH, NC 27605 -- •'•4 PHONE 919-733-4996 FAX 919-715-3605 AN EQUAL OPPORTUNITY /AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/10% POST -CONSUMER PAPER Permit Modification, Landfill Expansion White Oak Sanitary Landfill 6 OPERATIONS PLAN The approved Operations Plan will remain unchanged and is the primary reference for the operations in the new Waste Cell 4. This plan (reproduced in Appendix A) is contained in the Transition Plan dated April, 1994 prepared by DSA Design Group, Inc. Also refer to the previously submitted and approved WOSLF design plans by DSA Design Group dated September, 1992 and the Approved Plans submitted by Tribble and Richardson. Inc. A summary of the contents and characteristics of the Operations Plan is contained in this section. 6.1 LANDFILL DEVELOPMENT Waste will be accepted in baled form from the Haywood County Materials Recovery Facility (MRF). These bales will be placed in lifts of up to 12 feet in depth. Each lift will be covered with 6 inches of daily cover. Final cover will consist of at least 24 inches of soil (or bentonite-augmented soil) with a permeability of less than or equal to 1x10-7 cm/s covered with a 30 mil low -density polyethylene (LDPE) FML and at least 6 inches of topsoil. 6.2 BORROW AREA OPERATIONS SRK submitted a plan to utilize the proposed borrow area to the south of the current landfill limits. Approval to excavate in this area was sought and acquired through submittal to DEHNR, Land Quality Division of an updated Sediment and Erosion Control Plan dated January 27, 1997. DSWM was also given proper notification. This plan and attached drawings detailed excavation limits and sediment and erosion control. This borrow area will be utilized during the life of the new Waste Cell 4. 6.3 WASTE ACCEPTANCE AND DISPOSAL REQUIREMENTS The WOSLF will continue to refuse waste outlined in Section 7.4 of the Transition Plan. This waste includes but is not limited to hazardous waste, PCBs (polychlorinated biphenyls), and liquid sludge. All waste accepted shall be disposed in the manner described in Section 7.5 of the Transition Plan. 6.4 SPREADING AND COMPACTING REQUIREMENTS Baled waste shall be placed in the landfill to achieve the following goals: (1) keep working area as small as possible; (2) follow the downgradient direction during placement; (3) pack the waste as densely as practical into daily cells; and (4) collect windblown debris on a regular basis. SRK Project No. 83505 Page 6-1 June 16, 1997 Permit Modification, Landfill Expansion White Oak Sanitary Landfill 6.5 HAZARDOUS AND LIQUID WASTES SCREENING PROGRAM The WOSLF will continue to implement the requirements of the Hazardous and Liquid Wastes Screening, Prop*ram currently in place. This program is divided into two parts, (1) hazardous and liquid waste spotting and (2) random load inspections. The requirements of both parts are covered in section 7.7 of the Transition Plan. 6.6 COVER MATERIAL REQUIREMENTS AND VECTOR CONTROL A minimum of 6 inches of daily cover will be placed on waste in the new cell to control blowing debris and vector populations. Intermediate cover material cover requirements are outlined in Section 7.8 of the Transition Plan. 6.7 EXPLOSIVE GAS CONTROL Section 7.10 of the Transition Plan details measures required to detect and respond to explosive gas build-up. Several methane monitoring points have been established for sampling methane concentrations. Limits established by State regulations are reiterated in this section along with steps required in the event of detection of gas concentrations above those thresholds. 6.8 RECORD KEEPING The WOSLF personnel shall keep records of the daily operations of the landfill. These parameters are outlined in section 7.15 of the Transition Plan and will continue to be implemented in the new Waste Cell 4. SRK Project No. 83505 Page 6-2 June 16, 1997 Permit Modification, Landfill Expansion White Oak Sanitary Landfill APPENDIX A DSA Design Group, Inc. Operations Plan from Transition Plan, April 1994 SRK Project No. 83505 June 16, 1997 CHAPTER 7 - OPERATION PLAN 4 7.1 Operational Drawings Refer to the previously submitted and Approved White Oak Sanitary Landfill design plans by DSA Design Group dated September, 1992 and the Approved Plans submitted by Tribble and Richardson, Inc. Also refer to the attached "as -built' drawing for other information including water quality and explosive gas monitoring locations. The landfill will be operated so as to facilitate closure at any time while keeping the height of the landfill to a minimum by phasing from low to high areas. This will be accomplished by placing waste in layers and cells as indicated in the Approved Operations documentation. Operators will keep the size of the active area to a minimum. Landfilling may begin by placing baled waste in daily lifts of up to 12 feet in depth. Each lift will be covered with 6 inches of daily cover soil and graded to drain away from the working area. When the placing of waste reaches the elevation of the top of the embankment the outside face of the waste shall be graded to match the slope of the outside face of the embankment (i.e., 3:1). Embankment faces will be covered with a minimum of 12 inches of intermediate cover soils and temporarily vegetated. The slope of the outside face of the landfill will be interrupted every 20-30 feet. in vertical height by a bench with a drainage channel (refer to the approved closure contours shown on the Tribble & Richardson plans). The benches will help increase stability and reduce the slope length and erosion of the outside face of the landfill. The bench channels will be drained via slope drain pipes similar to those being presently utilized at the landfill. Runoff from the landfill will be directed, via diversion channels, to the existing riser barrel sediment basin located to the north of the waste cell. The existing sediment basin will be excavated to its original or appropriate dimensions and regularly maintained. Maintenance shall include inspection and repair as needed to the embankment and spillway, cleaning or replacement of the gravel filter, and other repairs to ensure proper operation of all sediment basins. Sediment shall be removed from the basin when the accumulated sediment reaches one-half of the basin or trap depth. In accordance with state regulations, a final cover layer consisting of at least 24 inches of soil (or bentonite augmented soil) with a permeability less than or equal to 1 x 10"' cm/s covered with a 30 mil flexible membrane liner and at least 6 inches of topsoil shall be installed on the top and on outside slopes as soon as practical after the slopes are brought to final grade. The final cover shall be seeded immediately after installation to reduce erosion. Vegetation should be established within 30 working days or 120 days of completion of a phase of the landfill. DSA Design Group 13 Transition Plan Haywood County The cover and embankment soils for the existing operating landfill will be excavated onsite and stockpiled near the working area to be used for operational and final cover soils. The operational soils will be obtained from the approved borrow areas. 7.3 Borrow Area Operations The required daily, intermediate, and final cover soils will be obtained from the existing and expanded borrow areas. The expanded borrow area consists of approximately 5 acres of wooded land that lies to the south of the borrow area currently being excavated (refer to drawings). The expanded borrow area soils were investigated by Law Engineering during the original geotechnical evaluation for the site. Test pits were excavated in the expanded borrow area in order to explore the general subsurface conditions, evaluate soil properties, and to provide information for an estimation of the quantity of cover soils available. 7.4 Waste Acceptance The landfill accepts only waste generated in Haywood County and does not/will not accept any of the following: • Hazardous Waste as defined in 15A NCAC 13A; • PCBs (polychlorinated biphenyls); • Liquid Sludge; • Lead Batteries; • Asbestos; and • Liquid and Wastes Containing Free Moisture including the following: • Bulk or Non -containerized Liquid Wastes unless the waste is household waste; • Septic Waste or Waste Oil; • Barrels or Drums unless they are empty and perforated sufficiently to ensure that they contain no liquid or hazardous waste; and • Containers Holding Liquid Waste unless the container is a small container similar is size to that normally found in household waste, the container is designed to hold liquids for use other than storage, or the waste is household waste. A waste is liquid, or contains free moisture, if it fails the Paint Filter Test (see Hazardous and Liquid Waste Screening Program for details). DSA Design Group 14 Transition Plan Haywood County 7.5 Disposal Requirements The following items shall be disposed in the manner described below: • All Municipal Solid Waste received for landfilling shall be placed within the limits of the composite liner system. • Spoiled food, animal carcasses, abattoir (slaughterhouse) waste, hatchery waste, and other animal waste shall be covered immediately. • Asbestos waste, if accepted, should be covered immediately with soil in a manner that will not cause airborne conditions and must be disposed of separate and apart from other solid wastes at the bottom of the working face. It is current landfill policy not to accept asbestos for disposal. • Wastewater Treatment Sludges will only be accepted if utilized as a soil conditioner and incorporated into or applied to the erosion layer of the final cap system, but in no case greater than six inches in depth. It is current landfill policy not to accept sludge for disposal. • Tires will be collected and stored in a separate designated area at the MRF and convenience centers for periodic removal and processing, or for proper disposal. 1 • White Goods shall be collected and stored at the MRF. The CFCs shall be removed and the remaining appliance shall be salvaged or landfilled at the bottom of the working face. Currently all white goods are being removed and reused. ' • Wood Waste and Yard Waste shall be disposed of at another location approved by DSWM. Currently, the approved LCID landfill in Canton is receiving this waste. DSA Design Group 15 Transition Plan Haywood County 7.6 Spreading and Compacting Requirements Operations for the landfill unit are more detailed in the Operation Plan and Operational Supplemental Document contained in the Approved Plan. Briefly, landfilling shall be performed in general accordance with the following placement requirements: • Daily placement of baled solid waste will be restricted to the smallest area feasible. Keeping the active area as small as possible will: • minimize leachate generation; • decrease the quantity (not thickness) of cover soils used; • increase bale placement efficiency; • decrease potential of litter problems (blowing waste); and • discourage scavenging and permit the bales to be placed and covered in less time. • In general, solid waste (bales) should be deposited at the bottom of the active face and placement should progress downgradient along the waste cell. Bales should be stacked according to a maximum 5:1 ratio; that is to say 5 bales should be placed along the toe before one is placed on top. This results in: • bale stability will be ensured, and the tumbling of bales will be mitigated; • better bale placement, as bales can be placed so that stormwater can shed away from the working face over covered waste; • better visibility, comfort, and safety for equipment operators; and • better litter control due to less exposure to wind and less surface area of the waste. Special daily field or disposal conditions may make downslope operations impractical. The judgement of the landfill operations manager will prevail concerning day-to-day operations. • Bales should be placed as densely as practical into daily cells. Maximum placement efficiency of solid waste can be achieved by: • placing bales in one to two -bale height lifts (no more than six feet high); • minimize soils placement between bales and maintain bale alignment to ensure uniformity; • maintain active area slopes at or less than 3:1 (33%). • Windblown waste resulting from operations shall be collected and returned to the disposal area on a regular basis. Haywood County may wish to construct a portable litter fence if it is determined there is a prevailing wind direction at the landfill. DSA Design Group 16 Transition Plan Haywood County 7.7 Hazardous and Liquid Wastes Screening Program The following screening program is a modification of the existing Random Load Inspection Program established for Haywood County. Currently, random deliveries of solid waste are inspected each week of operations at the Materials Recovery Facility (MRF) located on Recycle Road in Clyde, NC. It is important to prohibit the disposal of hazardous and liquid wastes at the White Oak Landfill due to the potential risk to human health and the environment. Provisions in the NC Solid Waste Management Rules place long-term liability on Haywood County. The Hazardous and Liquid Waste Screening Program consists of two parts, (1) Hazardous and Liquid Waste Spotting and (2) Random Load Inspections. Definitions: Characteristic Waste - Wastes which are deemed to be hazardous due to their nature. A waste is a characteristic hazardous waste if it is not a listed waste but exhibits one or more of the following four characteristics: ignitable, corrosive, reactive, or TCLP toxic. Corrosive - A waste is corrosive if the pH of the waste is less than 2 or greater than 12.5. Hazardous Waste - Wastes with characteristics, either physical or chemical, that could harm human health or the environment. A waste is categorized as hazardous if it meets either of the two following criteria: (a) a listed waste or (2) a characteristic waste. For landfilling purposes, a waste is NOT defined as hazardous if it is a household waste or household hazardous waste (HHW). Household Waste - Wastes (including garbage, trash and liquids) derived from households (including single and multiple' residences, hotels, motels, and other residential sources). Household Hazardous Waste (HHW) - Waste which meets the criteria of a hazardous waste and is derived from households. Household hazardous waste is allowed, by the NC Solid Waste Management Rules, for disposal at municipal solid waste landfills. Ignitable - A waste is ignitable if it has a flash point (will ignite) at a temperature of less than 140°F, causes a fire by friction under normal circumstances, or is an oxidizer. Examples of ignitable wastes include solvents, peroxide and petroleum products. Common sources of ignitable waste include automobile repair shops, machine shops and dry cleaners. Listed Waste - Listed wastes are specific chemical compounds which have been deemed by the EPA to present significant risks to human health and the environment. The EPA's "Lists of Hazardous Wastes" are contained in 40 CFR 261.30 - 261.33 (Subpart D). DSA Design Group 17 Transition Plan Haywood County Liquid Waste - Waste shall be considered liquid if the waste fails the Paint Filter Test as described below: Paint Filter Test: Place a 100 milliliter sample of waste in a conical, 400 micron paint filter. If any liquid passes through the filter in five minutes, the waste fails the test. Liquid wastes that are part of household waste are accepted at the landfill. PCBs - Polychlorinated biphenyls (PCBs) are a toxic material with the potential for poisoning animal and plant life and do not degrade over time. Examples of materials which may contain PCBs are transformers, capacitors and hydraulic systems. Reactive - A waste is reactive if it is normally unstable; reacts violently with water; forms an explosive mixture with water; contains quantities of cyanide or sulfur that could be released to the air; or can easily be detonated or exploded. TCLP Toxic - A waste is TCLP (Toxicity Characteristic Leaching Procedure) toxic if the concentration of any of the constituents listed below exceeds the standard assigned to that substance shown in parentheses. Arsenic (5.Omg/1)' Barium (100) Benzene (0.5) Cadmium (1.0) Carbon Tetrachloride (0.5) Chlordane (0.03) Chlorobenzene (100.0) Chloroform (5.0) Chloroform (6.0) Chromium (5.0) o-Cresol (200.0) m-Cresol (200.0) p-Cresol (200.0) Cresol (200.0) 2,4-D1 (10.0) 1,4-Dichlorobenzene (7.5) 1,2-Dichloroethane (0.5) 1,1-Dichloroethylene (0.7) 2,4-Dinitrotoluene (0.13) Endrin (0.02) Heptachlor (0.008) Hexachlorobenzene (0.13) Hexachloroethane (3.0) Lead (5.0) Lindane (0.4) Mercury (0.2) Methoxychlor (10.0) Methyl ethyl ketone (200.0) Nitrobenzene (2.0) Pentachlorophenol (100.0) Pyridine (5.0) Selenium (1.0) Silver (5.0) Tetrachloroethylene (0.7) Toxaphene (0.5) Trichloroethylene (0.5) 2,4,5-Trichlorophenol (400.0) 2,4,6-Trichlorophenol (2.0) 2,4,5-TP (Silvex) (1.0) Vinyl Chloride (0.2) The TCLP is designed to detect heavy metals, pesticides and a few other organic and inorganic compounds in order to prevent groundwater contamination by highly toxic materials. DSA Design Group 18 Transition Plan Haywood County Hazardous and Liquid Waste Spotting: County personnel working at the scales, MRF and the active face of the landfill shall watch for suspicious wastes at all times. Personnel shall watch for the following: • Hazardous placards, labels or markings • Liquids • Powder, dust, or vapors • Sludges • Bright or unusual colors • Drums or commercial size containers • 'Chemical" or unusual odors • Other waste not accepted at the landfill MRF personnel shall pay special attention to waste originating from: • auto repair and machine shops (solvents, paint wastes, lead acid batteries, grease and oil), • dry cleaners (filters containing dry cleaning solvents), and • other industries which generate a variety of undesirable wastes; e.g. chemical and related products, petroleum refining, primary metals, electrical and electronic machinery. IF HAZARDOUS, LIQUID OR SUSPICIOUS WASTE IS DISCOVERED, landfill personnel shall proceed in accordance with the following: 1. Instruct the hauler to remain at the MRF until waste acceptance is determined by the Haywood County Emergency Management Coordinator and the appropriate information is obtained from the hauler to complete the Hazardous and Liquid Waste Screening Report. 2. Complete a Hazardous and Liquid Waste Screening Report and place a copy of the Report in the Operating Record. If the waste is identified while still in the haul vehicle, the MRF/landfill manager may refuse the load, however the following steps still must be completed. 3. Contact the Haywood County Solid Waste Director - Keith Burris (704-627-8137) and the Haywood County Emergency Management Coordinator - Nolan Palmer (704-452- 6660). 4. Segregate the suspicious waste if safe to do so. DSA Design Group 19 Transition Plan Haywood County 5. 1.1 7 Allow the Emergency Management Coordinator to determine if the waste is hazardous or liquid. If the waste is determine to be hazardous or suspicious, Haywood County Emergency Management Personnel will: a. Notify the Local Office of Emergency Management (Asheville) and the State Office of Emergency Management (Raleigh). b. Contact a licensed hazardous waste hauler to remove and properly dispose of the waste, or advise the original hauler to properly remove and dispose of the waste. A list of licensed hazardous waste cleanup contractors is available from the Haywood County Emergency Management Coordinator. c. The MRF/landfill manager shall complete the remaining steps of this procedure. If the waste is determined to be liquid (and non -hazardous) by the Haywood County Emergency Management Personnel, the MRF/landfill manager will: a. Require the hauler of the waste to remove the liquid waste from the MRF, or arrange for its proper transport and disposal. b. Refer to Section 7.4 Waste Acceptance for requirements on the acceptance of liquid waste. c. Complete the remaining steps of this procedure. If waste is to be removed from the site or if further on -site analysis is required and must remain on site overnight, cover the waste securely with a waterproof tarp or segregate the waste to a dry, covered area within the MRF. Notify the Division of Solid Waste Management (919-733-0692) within 24 hours of attempted disposal of any waste the landfill is not permitted to receive, including hazardous and liquid wastes, PCBs, and waste from outside Haywood County. DSA Design Group 20 Transition Plan Haywood County Random Load Inspections: Random Load Inspections shall be performed on randomly selected loads originating in part or total from commercial and/or industrial sources. Loads consisting entirely of household (residential) waste should not normally be included in the Random Load Inspection Program. Household hazardous/liquid waste is accepted at the White Oak Landfill, however, landfill personnel shall stay alert to household hazardous/liquid waste for their own protection. Selection of Random Loads: The Haywood County MRF receives approximately 75 loads of municipal solid waste per day. One (1) Random Load Inspection shall be performed each week, however, all loads deemed by the MRF operator to be suspicious should be inspected and documented. The random load to be inspected will be determined by selecting the day of the week and the time of day at which the load crosses the MRF scale. Each operating week prior to opening for disposal operations, the MRF personnel will randomly select a day and time (e.g. Tuesday, 10:45 a.m.). The first load of waste, containing all or part commercial or industrial waste, which crosses the scales on or after the selected time will be the load inspected that day. If the randomly selected load is determined to consist entirely of household waste (no commercial or industrial waste) then the inspection shall be performed on the next load 4 crossing the scales containing, in part or total, commercial and/or industrial waste. Random Load Inspection Procedure: 1. Prior to accepting waste the MRF operator will designate an area to be used for random load inspection. The designated area shall be dry and away from other received waste on the MRF floor. 2. The randomly inspected vehicle will be directed to the designated area. 3. The waste should be inspected, as completely as possible, while still in the vehicle before dumping the load. If any of the items listed in step 5 below are observed then the operator should request that the hauler remain on site until waste acceptance is determined by the Haywood County Emergency Management Coordinator and the appropriate information is obtained from the hauler to complete the Hazardous and Liquid Waste Screening Report. The operator should then complete the Hazardous and Liquid Waste Screening Report and contact the Haywood County Solid Waste Director - Keith Burris (704-627-8137) and the Haywood County Emergency Management Coordinator - Nolan Palmer (704-452-6660). Allow the Emergency Management Coordinator to determine the method of disposal of the waste. DSA Design Group 21 Transition Plan Haywood County 4. If no hazardous or liquid wastes are initially observed in Step 3 then the load shall be { dumped in the area designated in Step 1 and spread out with a loader. Additional spreading of the load shall be carefully performed by MRF personnel. Any bagged or baled waste shall be broken up and spread out for observation. 5. MRF and landfill personnel shall perform a visual inspection of the waste. Below is a list of items to look for: • Hazardous labels or markings • Liquids • Powder, dust, or vapors • Sludges • Bright or unusual colors • Drums or commercial size containers • 'Chemical` or unusual odors • Other waste not accepted at the landfill 6. Complete the Hazardous and Liquid Waste Screening Report and place a copy in the landfill's Operating Record. This report should be completed for each random load inspection whether or not hazardous/liquid waste is found. 7. If hazardous, liquid or suspicious waste is found, landfill personnel should follow the procedure outlined above entitled OF HAZARDOUS, LIQUID OR SUSPICIOUS WASTE IS DISCOVERED'. DSA Design Group 22 Transition Plan Haywood County FIGURE 7a - HAZARDOUS AND LIQUID WASTE SCREENING REPORT WHITE OAK LANDFILUMRF A. GENERAL INFORMATION: Date: Inspector: Time: Weather: Screening Type: Random Load Inspection, Spotted at Working Face/MRF, Spotted in Haul Vehicle. B. HAULER INFORMATION: Hauler Name: Driver Name & Lic. No.: Waste Generators: C. WASTE INFORMATION: Vehicle No./Tag No.: Waste Identified as: _ Non -Hazardous, Non -Liquid (Load acceptable) _ Suspicious (Explain below) _ Hazardous Waste (Explain below) _ Liquid Waste (Explain below) Notes: D. DISPOSAL INFORMATION: Weight of Load: Hauler Phone No.: Waste Disposal: Accepted Refused (Removed by hauler) Covered and temporarily stored on site for further tests (Attach additional documentation) Removed by hauler licensed to transfer hazardous waste (Attach additional documentation) GENERAL INSTRUCTIONS: The White Oak Landfill/MRF Hazardous/Liquid Waste Screening Report shall be completed upon either of the following instances: A Random Load Inspection • Spotting of a hazardous, liquid, or suspicious waste at the landfill gate, scales, or active face. 1. All MRF/landfill personnel shall stay alert for possible hazardous and liquid wastes at all times at the gate and active face. Special attention shall be given to waste loads originating from commercial and industrial sources. Household hazardous and household liquid wastes are acceptable at the landfill. 2. If a hazardous, liquid or suspicious waste is discovered while in a haul vehicle or on the landfill contact the Haywood County Solid Waste Director and the County Emergency Management Coordinator. 3. Notify the Division of Solid Waste Management (919-733-0692) within 24 hours of attempted disposal of a y waste the landfill is not permitted to receive, including hazardous and liquid wastes, PCBs, and waste from outside of Haywood County. 4. Place a copy of all completed Hazardous/Liquid Waste Screening Reports in the Operating Record. 5. Refer to the White Oak Landfill Transition Plan for more detailed information and instructions. Solid Waste Director - Keith Burris (704)627-8137 Emergency Management Coordinator - Nolan Palmer (704)452-6660. DSA Design Group 23 Transition Plan Haywood County 7.8 Cover Material Requirements All disposed solid waste must be covered with six inches of daily cover soils at the end of each operating day, or at more frequent intervals if necessary, to control disease vectors, fires, odors, blowing litter, and scavenging. Areas which will not have additional wastes placed on them for 12 months or more, but where final termination of disposal operations has not occurred, shall be covered with a minimum of 12 inches of intermediate cover soils and vegetated. 7.9 Disease Vector Control The appropriate use of daily and intermediate cover and the Disposal Requirements outlined in Section 7.5 of this chapter should be utilized by landfill personnel to control on -site populations of rodents, flies, mosquitoes, other animals, or insects, capable of transmitting disease to humans. If additional means of control are deemed necessary, landfill personnel shall contact the Waste Management Specialist, Jim Patterson (704-251-6208) for the facility regarding alternative solutions. Do not apply insecticides, pesticides or other chemicals to the landfill. 7.10 Explosive Gas Control Methane gas (CHJ is a by product of anaerobic decay (without free elemental oxygen) of organic constituents contained in solid waste, wastewaters, sludges, or naturally occurring features such as swamps. Methane, frequently referred to as swamp gas or marsh gas, along with carbon dioxide (CO2) comprise the major constituents (approximately 99%) of landfill gas. Evidence of anaerobic decomposition resulting in methane release can be observed as the bubbling that occurs in a stagnant body of water when the bottom is disturbed thereby releasing the trapped methane gas. Methane gas generation and migration can pose serious health and safety problems. One should -- understand the characteristics of methane gas in order to appreciate the potential threats it poses. Methane gas is lighter than air and consequently will rise given the opportunity. Methane has a specific gravity of 0.554, based on air having a specific gravity of one (1.0). Methane gas is odorless and colorless and has a flammable range of 5-15% by volume in air. The Lower Explosive Limit (LEL) is thus 5%. Methane as with any fluid will seek the path of least resistance when it flows or migrates. With the non -homogeneous nature of a landfill's contents, predictions as to where methane may migrate are difficult, thus the need to monitor its presence in enclosed areas, confined spaces and at landfill property boundaries. There are documented cases where methane has migrated underground several hundred feet from landfills to adjacent areas and even into basements or crawl spaces of residences. The dangers posed by methane are well known and there are numerous documented incidences of explosions caused by methane. The gas can be trapped in unvented or poorly vented areas such as crawl spaces or even seep into buildings. There is also danger to personnel from asphyxiation upon entering confined spaces where methane may have displaced some of the normal atmospheric air. Of course there are other gases present from the biological decomposition. Many of these gases are organic acids and do have an odor. Carbon monoxide is also likely to be present as it is a product of anaerobic decay. Thus confined space entry procedures should be employed prior to entering such spaces. Confined space entry procedures generally consist of checking the space for the presence of explosive gases, carbon monoxide and oxygen deficiency, venting the confined space, and then entering only if necessary and equipped with life support breathing apparatus, safety lines, and safety personnel standing by. Gas detection meters are commercially available and can be purchased to detect a number of gases or gas categories. DSA Design Group 24 Transition Plan Haywood County The concentration of methane gas (CH,) at the landfill must be monitored on a regular basis. An approved Permanent Gas Monitoring System must be constructed on or before October 9, 1994. The Temporary Gas Monitoring System must be used until the Permanent Gas Monitoring System is complete. The following requirements pertain to both the Permanent and Temporary Gas Monitoring Systems: Methane Gas Limits 25% of the LEL of methane in all FACILITY STRUCTURES. 100% of the LEL of methane at the facility PROPERTY BOUNDARY. The LEL (Lower Explosive Limit) is the lowest percent by volume of a mixture of explosive gases in air that will propagate a flame at 25`C and atmospheric pressure. The LEL for methane is 5% by volume in air. Monitorina Freauencv Gas monitoring shall be performed, at a minimum, every three (3) months unless directed otherwise by DSWM. IF METHANE GAS CONCENTRATIONS ARE FOUND TO BE IN EXCESS OF THE LIMITS' listed above, the danger of explosion is high and landfill personnel shall proceed in accordance with the following: 1. Immediate action must be taken to protect human health from potentially explosive conditions. All persons should be evacuated from the area immediately. 2. Leave the door to the evacuated structure open for ventilation. 3. From a safe location, contact the Haywood County Solid Waste Coordinator - Keith Burris (704- 627-8042) and the Haywood County Emergency Management Coordinator - Nolan Palmer (704- 452-6660). 4. Notify the Division of Solid Waste Management (919-733-0692). 5. Within seven days of detection, place in the operating record the methane gas levels detected and a description of the steps taken to protect human health. 6. Within 60 days of detection, develop and implement a remediation plan for the methane gas releases, place a copy of the plan in the operating record, and notify the Division of Solid Wasts Management that the plan has been implemented. The plan shall describe the nature and exte of the problem and the proposed remedy. 'This page was revised on July 26, 1994 as required by comments made by DSWM. A response plan was developed for the Landfill Gas Monitoring System proposed for the White Oak Sanitary Landfill in Haywood County. Additionally, the methane detection limits were corrected to correspond with State requirements. . _ DSA Design Group 25 Transition Plan Haywood County The concentration of methane gas (CHj at the landfill must be monitored on a regular basis. An t approved Permanent Gas Monitoring System must be constructed on or before October 9, 1994. The Temporary Gas Monitoring System must be used until the Permanent Gas Monitoring System is complete. The following requirements pertain to both the Permanent and Temporary Gas Monitoring Systems: Methane Gas Limits 100% of the LEL of methane in all FACILITY STRUCTURES. 25% of the LEL of methane at the facility PROPERTY BOUNDARY. The LEL (Lower Explosive Limit) is the lowest percent by volume of a mixture of explosive gases in air that will propagate a flame at 250C and atmospheric pressure. The LEL for methane is 5% by volume in air. Monitoring Frequency Gas monitoring shall be performed, at a minimum, every three (3) months unless directed otherwise by DSWM. DSA Design Group 25 Transition Plan Haywood County Permanent Gas Monitoring System Narrative: The Permanent Gas Monitoring System is being proposed with the submittal of this Transition Plan to DSWM. This system or the entire Transition Plan must be approved by DSWM before the system can be installed and monitored. The Permanent Gas Monitoring System consists of gas monitoring wells located along the compliance boundary of the facility (refer to the attached plan for well locations) and an outlined procedure for monitoring of the gas wells and on -site structure(s). Equipment: • Explosive gas detection meter (meter) capable of measuring the percent of LEL and/or concentration of methane gas (combustible gasses) by volume in air. • Permanently installed gas monitoring wells along the facility's compliance boundary. Gas monitoring procedure: 1. Make arrangements with neighbors to measure gas in nearby structures, if needed. 2. Calibrate the meter according to the manufacturer's recommendations. Measure the concentration of methane gas in the FACILITY STRUCTURES before any heat source or fuel has been turned on in the structure. Take measurements in the basement or crawl space, near the floor along walls were gas may enter from below, and in every room of the structure. Record, in the Gas Monitoring Record, the concentrations and/or percent of LEL of methane gas for each location. 3. Measure -gas as described in step 2. in nearby structures with owner's approval. Record results. 4. At each gas monitoring well, remove well cap and insert meter probe into well to approximately two (2) feet into well casing. Perform measurement of concentration or percent of LEL of methane gas in the well. Record measurements. Replace well cap. 5. Proceed to next monitoring point and repeat steps 4 & 5 until all locations have been monitored and recorded. 6. Place monitoring results in on -site landfill records. 7. Submit copy of test results to: Division of Solid Waste Management "Gas Monitoring Results" P.O. Box 2678 Raleigh, NC 27611-7687. 8. If methane gas concentrations are found to be in excess of the established limits, the danger of explosion is high and landfill personnel shall follow the procedure oullinec c_ page 26". This page was revised on July 26, 1994 as required by comments made by DSWM. A response plan was developed for the Landfill Gas Monitoring System proposed for the White Oak Sanitary Landfill in Haywood County. Additionally, calibration of the detection meter was noted. DSA Design Group 26 Transition Plan Haywood County Permanent Gas Monitoring System Narrative: The Permanent Gas Monitoring System is being proposed with the submittal of this Transition Plan to DSWM. This system or the entire Transition Plan must be approved by DSWM before the system can be installed and monitored. The Permanent Gas Monitoring System consists of gas monitoring wells located along the compliance boundary of the facility (refer to the attached plan for well locations) and an outlined procedure for monitoring of the gas wells and on -site structure(s). Equipment: Explosive gas detection meter (meter) capable of measuring the percent of LEL and/or concentration of methane gas (combustible gasses) by volume in air. Permanently installed gas monitoring wells near the compliance boundary of the facility. Gas monitoring procedure: Using the meter, measure the concentration of methane gas in the FACILITY STRUCTURES before any heat source or fuel has been turned on in the structure. Take measurements in basement or crawl space, near the floor along walls where gas may enter from below, and in every room of the structure. Record, in the Gas Monitoring Record, the concentrations and/or percent of LEL of methane gas for each location. 2. At each gas monitoring well, remove the well cap and insert the meter probe into the well approximately two (2) feet into the well casing. Perform measurement of concentration or percent of LEL of methane gas in the well. Record measurements. Replace the well cap. 3. Submit copy of test results to: Division of Solid Waste Management Solid Waste Section "Gas Monitoring Results" P.O. Box 26787 Raleigh, NC 27611-7687 DSA Design Group 26 Transition Plan Haywood County 4"X 4" TREATED POST PAINTED ORANGE WITH IDENTIFYING LABEL IN BLACK LETTERS i a LL J LOCK S 0 PROTECTIVE OUTER CD COVER of1 2'x 2'x 4" CONC. PAD 11 0 CV NATIVE SOIL GROUT BENTONITE 4'4" WASHED GRAVEL BACKFILL TABLE BOREHOLE O.D. = 12" PIPE O.D. = 2" PIPE TYPE = PVC SCH 40 SCREEN SLOT SIZE = 0.010" DEPTH TO TOP OF BENTONITE = 2' DEPTH TO TOP OF GRAVEL = 3 EPTH TO TOP CRFFN = 3.5 NATIVE SOIL BOREHOLE TO 1' TO 2' ABOVE SEASONAL HIGH WATER TABLE OR TOP OF BEDROCK, WHICHEVER IS SHALLOWER. GAS MONITORING WELL NOT TO SCALE Temporary Gas Monitorina System Narrative: Until approval and installation of the Permanent Gas Monitoring System, landfill personnel will utilize the Temporary Gas Monitoring System as outlined below. The Temporary Gas Monitoring System consists of measuring concentrations of methane gas at the property line and on -site structures. The initial Temporary Landfill Gas Monitoring event for the White Oak Sanitary Landfill is scheduled for April 13, 1994. A report of these readings will be sent to DSWM. Equipment: Explosive gas detection meter (meter) capable of measuring the percent of LEL and/or concentration of methane gas (combustible gasses) by volume in air. Metal stake with bullet end capable of being driven 2'/2 to 3 feet into the ground and removed leaving a hole large enough for insertion of the explosion meter probe. Gas monitoring procedure: 1. Calibrate the meter according to the manufacturer's recommendations. Measure the concentration of methane gas in the FACILITY STRUCTURES before any heat source or fuel has been turned on in the structure. Take measurements in the basement or crawl space, near the floor along walls where gas may enter from below, and in every room of the structure. Record, in Gas Monitoring Record, the concentrations and/or percent of LEL of methane gas for each location. 2. At the monitoring point on the property boundary, drive stake into the ground to a depth of 2'/z feet. Remove stake and insert the meter probe. Perform measurement for concentration or percent LEL of methane gas. Record measurement. 3. Proceed to next monitoring point and repeat steps 1 & 2 until all locations have been monitored and recorded. 4. Place monitoring results in the on -site landfill records. Submit copy of test results to: Division of Solid Waste Management "Gas Monitoring Results" P.O. Box 26787 Raleigh, NC 2761 1-7687 6. If methane gas concentrations are found to be in excess of the established limits, the danger of explosion is high and landfill personnel shall follow the procedure outlined cn page 26'. 'This page was revised on July 26, 1994 as required by comments made by DSWM. A response plan was developed for the Landfill Gas Monitoring System proposed for the White Oak Sanitary Landfill in Haywood County. Additionally, calibration of the detection meter was noted. DSA Design Group 27 Transition Plan Haywood County Temporary Gas Monitoring Svstem Narrative: Until approval and installation of the Permanent Gas Monitoring System, landfill personnel will utilize the Temporary Gas Monitoring System as outlined below. The Temporary Gas Monitoring System consists of measuring concentrations of methane gas at the property line and on -site structures. The initial Temporary Landfill Gas Monitoring event for the White Oak Sanitary Landfill is scheduled for April 13, 1994. A report of these readings will be sent to DSWM. Equipment: • Explosive gas detection meter (meter) capable of measuring the percent of LEL and/or concentration of methane gas (combustible gasses) by volume in air. • Metal stake with bullet end capable of being driven 21h to 3 feet into the ground and removed leaving a hole large enough for insertion of the explosion meter probe. Gas monitoring procedure: 1. Using the meter, measure the concentration of methane gas in the FACILITY STRUCTURES before any heat source or fuel has been turned on in the structure. Take measurements in the basement or crawl space, near the floor along walls where gas may enter from below, and in every room of the structure. Record, in Gas Monitoring Record, the concentrations and/or percent of LEL of methane gas for each location. 2. At the monitoring point on the property boundary, drive stake into the ground to a depth of 21/2 feet. Remove stake and insert the meter probe. Perform measurement for concentration or percent LEL of methane gas. Record measurement. 3. Proceed to next monitoring point and repeat steps 1 & 2 until all locations have been monitored and recorded. 7. Place monitoring results in the on -site landfill records and send a copy to DSWM. DSA Design Group 27 Transition Plan Haywood County 7.11 Air Criteria A gas venting system is required and has been provided in the Approved Plan. The passive gas venting system consists of vertical wells installed progressively throughout the landfill cell and vented to the atmosphere. After construction, the passive system can be converted into a collection/flare system if the need or requirement arises (see paragraph below). At this time monitoring of the gas venting system in the landfill cap is not a requirement. The EPA is expected to promulgate regulations known as Subpart WWW of 40 CFR 60 which will regulate landfill gas as an air pollutant under the Clean Air Act (CAA). Within nine months after promulgation, North Carolina will develop a State Implementation Plan (SIP) which implements the EPA regulations. Landfill owners and operators will be required to ensure that their landfills do not violate any applicable requirements of the North Carolina SIP. Subpart WWW proposes to control landfill emissions by regulating nonmethane organic compounds (NMOC's) in the landfill gas. Landfills emitting more than 167 tons per year of NMOC's would be required to operate gas collection systems and combust the captured landfill gases. In most cases, the new collection systems will be connected to the existing passive gas venting system installed in the landfill cap. In the future, the White Oak Landfill may be required to perform annual testing and calculation of NMOC's emitted from the Passive Gas Venting System. 7.12 Access and Safety A locked electronic gate at the entrance to the facility and a perimeter, electrified fence is utilized to prohibit uncontrolled access to the landfill during off hours. Landfill personnel shall monitor the access to the landfill during operating hours. Landfill personnel shall construct and maintain all weather access roads as indicated on the Approved Operational Drawings. Apply water to access road outside of waste cell when needed to control dust. Landfill personnel shall maintain signs at facility which state: hours of operation; no hazardous or liquid waste accepted; the landfill permit number; and other pertinent information. Landfill personnel shall prohibit the removal of solid waste from the landfill unless removal is approved by the landfill operator and is not performed on the working face of the landfill. 7.13 Erosion and Sediment Control The Erosion and Sediment Control Plan for the White Oak Landfill was submitted to 1992 as part of the approved White Oak Landfill Construction Plan. Approval of the Sediment Control Plan was issued by the Division of Land Resources in July, 1993. of the Erosion and Sediment Control Plan Report is provided in the Approved Plan. previously submitted and approved White Oak Landfill Design Plans for Erosion anc Plan and Details. DSWM in March, Erosion and A complete copy Refer to the Sediment Control DSA Design Group 28 Transition Plan Haywood County 7.14 Drainage Control and Water Protection Landfill personnel shall ensure that surface water is diverted from the operational area with the utilization of bench ditches, temporary channels, berms, slope drains, culverts, and other means as necessary to maintain positive surface drainage off the landfill. At no time shall surface water be allowed to collect over waste or waste be disposed of in water. Landfill personnel shall utilize slope benches, slope drains, channels, and other methods indicated in the approved Erosion and Sediment Control Plan and the Operational Drawings to control drainage and prevent excessive erosion. The sediment basin shall be maintained to prevent excessive sediment from leaving the property. Surface water shall be monitored as detailed in Chapter 12 - Water Quality Monitoring. 7.15 Record Keeping A copy of the following items shall be kept in an Operating Record for the landfill at the MRF until it is closed at which time all records shall be kept at the office of the Haywood County Manager. • Approved Transition Plan including: • Water Quality Monitoring System Plan • Water Quality Sampling and Analysis Plan (SAP) • Hazardous and Liquid Waste Screening Plan • Erosion and Sediment Control Plan • Operational Plan • Closure Plan • Post -Closure Plan • Closure and Post -Closure Cost Estimate • Financial Assurance Documentation • Annual Updates of Closure and Post -Closure Cost Estimate • Amounts and Sources of Solid Waste Received • Solid Waste Permit and Amendments • Inspection/Evaluation Reports • Water Quality Monitoring Results • Gas Monitoring Results • Hazardous/Liquid Waste Screening Reports • Citizens' Complaints and Disposition • Closed Unit Certifications • Post -Closure Certification • All Correspondence • Other Pertinent Data and Records required by DSWM DSA Design Group 29 Transition Plan Haywood County ��s1�.VC1�IK �! a JAMES B. HUNTJR.`, NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WASTE MANAGEMENT April 29, 1998 C. Jack Horton Haywood County Manager 420 North Main Street Courthouse Annex Waynesville, NC 28786 Ref: Haywood County Permit Renewal Mr. Haywood: The Division of Waste Management, Solid Waste Section (Section) has completed the initial review of the Permit Application for the above referenced project. The following items must be provided or addressed in order to complete the review process. Revisions must be made in accordance with North Carolina Solid Waste Management Rule 15A NCAC 13B .1603(b). Section 1.0 Waste Cell 4 Permit Application Overview refers to seeking a permit modification to allow construction of the additional cell. The proposed revision seeks to expand the current landfill with additional lined cell area. This proposed area constitutes a lateral expansion of the footprint. Lateral expansions require a permit application and review under permit renewal. As such, the application should be revised to address the requirements of 15A NCAC 13B .1603(a)(5) and .1617(e). Solid Waste Management Rule 15A NCAC 13B 1603(a)(5) references the following: • 1622(1), (2), (3), (4), (5), and (6) • .1624(b)(1) and .1617(e) references the following: • 1619 • .1620 • 1621 • .1625 • 1629 • 1623(b) 401 OBERLIN ROAD, SUITE 150, RALEIGH, NC 27605 PHONE 919-733-4996 FAX 919-715-3605 AN EQUAL OPPORTUNITY /AFFIRMATIVE ACTION EMPLOYER - SO% RECYCLED/1 Oq POST -CONSUMER PAPER Haywood County Page 2 This review letter will attempt to correlate and address the applicable requirements as presented in the submitted modification application. However, it is the applicant's responsibility to ensure that all applicable rules requirements are submitted and addressed. .1619 Facility Plan The Section has no engineering comments or questions regarding the Facility Plan at this time. .1620 Engineering Plan The Section recommends that where perforated HDPE leachate collection pipe is located, extend the filter wrapped #57 stone through the protective sand layer such that the stone conveyance is in contact with initial waste layer. .1621 Construction Quality Assurance Plan Section 5.1.5.1.3 specifies that excavation lines may vary from those shown on the plans. Construction must be in accordance with the final Section approved plans, to include the grade lines shown. Adjustments in base grades must receive prior approval from the Section. Revise this section of the CQA plan accordingly. The earthwork and clay liner section of the CQA portion of the application does not specify which party is responsible for CQA testing. Rules require that the CQA or Project Engineer is responsible for certifying that the project is constructed in accordance with the approved plans and rules, to include CQA testing. If the bulk of the Construction Quality Control testing is performed by the contractor and to be used as CQA testing, then independent CQA verification testing will be required by the Section. Revise the CQA section of the application accordingly to clarify responsible parties and testing frequencies where applicable. Permeability testing frequency is not specified in Table 5-2. The Section recommends 1 undisturbed test per acre per lift. Clay liner thickness is generally verified by as built survey based upon measurements from a grid layout (typically 50 foot grid), except on side slopes where probes are typically utilized. One hand auger probe per acre is not acceptable. In addition, if auger holes are utilized, filling techniques were not provided (usually a tamped bentonite fill or bentonite blend fill). Testing and frequency to insure properties of the leachate drainage layer is not provided. CQA procedures for leachate pipe installation was not provided. Haywood County Page 3 Installation of geonets and geogrids are shown in selected areas. CQA plan not provided. Acceptable properties and CQA of the top 12 inches of 'native' soil protection, above the leachate collection layer, is not provided. Overall, the CQA portion of the application appears to be in the form of contract specifications between the owner and contractor rather than a CQA plan. Please review and revise the CQA plan to clarify construction tests, frequency, verifications, and the parties which will be responsible for providing such tests and information which will be presented to the Section in the CQA documentation. 1622 Location Restrictions for MSWLF Facility Siting Compliance with .1622(1) Airport Safety not provided. Compliance with .1622(2) Floodplains not specifically provided. However, location of proposed lateral expansion is obviously not located in a floodplain. General statement to that effect should be provided in the application or on the plans. Compliance with .1622(3) Wetlands not specifically provided. Location of proposed lateral expansion should have not wetlands impact. However, this should be addressed in the permit renewal application. Compliance with .1622(4) Fault areas not provided. Compliance with .1622(5) Seismic Impact Zones not provided. Compliance with .1622(6) Unstable Areas not provided. This is and evaluation of the overall site stability, not the calculations provided for side slope design. .1623(b) Design Hydrogeologic Report Please refer to correspondence from the Sections Hydrogeologists, Mr. Bobby Lutfy and Mr. Matt Gamble for comments and questions regarding .1623(b). .1624 Construction Requirements for MSWLF Facilities Indicate location of survey control monuments, tied to North Carolina State Plane coordinates. Provide information, construction and CQA, specific to the test pad for the clay liner system. The test pad can be located within the proposed cell. Haywood County Page 4 Acceptance and rejection criteria is not completely clear for .1624(b)(8)(B). While some components were found in the CQA plan, these overall parameters should be presented as part of the engineering design plan or supporting calculations appendix. .1625 Operations Plans for MSWLF Facilities The Section has no comments under .1625 and .1626 at this time. A copy of the operations plan has been has been sent to the Waste Management Specialist for additional review. Any forthcoming comments will be forwarded to you. The Section has not comments under .1629 at this time. The Section reserves the right to request additional information during the continuing review. If additional information is required, you will be notified by the Section. Should you have any questions concerning this review, please contact me at (919) 733-0692 extension 266 or Matt Gamble at extension 344. Thank you, William D. Sessoms, PE copy: Jim Patterson - DWM Matt Gamble, PG - DWM C:\SESSOMS\PROJECTS\HAYWOOD\PERM IT\LETTER.I