HomeMy WebLinkAbout5103_JohnstonLF_Phase6A_20210821Wilson, Donna J
From: Pieter Scheer <pieter@smithgardnerinc.com>
Sent: Friday, August 20, 2021 4:56 PM
To: Wilson, Donna J
Cc: Scheer, Pieter
Subject: [External] Johnston County MSWLF - Phase 6A Capacity & Update
Attachments: JC Phase 6A Capacity (JOHN-B0845).pdf; JC Phase 6A Capacity Isopach 2021-08-16.pdf
Follow Up Flag: Follow up
Flag Status: Flagged
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to
Report Spam.
Donna
Phase 6A Capacity: Per your prior request, attached is a drawing showing fill grades for Phase 6A and a cut/fill isopach
showing the capacity (1,041,557 CY) from top of protective cover to top of intermediate cover.
Project Update: Duke Energy has completed extension of a power line for the project and the electrician is set to make
final connections. This will be followed closely with the flushing/camera inspection of the leachate piping and the pump
startup. Additionally, we have provided updated financial assurance information to the County for submittal with their
local government financial test information and we have been performing the necessary monitoring
activities. Documentation for the pump startup and the piping inspection are the final pieces of information needed to
submit a final version of the CQA report.
Hope you have a nice weekend.
Pieter
Pieter K. Scheer, P.E.
Vice President, Senior Engineer
SMITH GARNNER
14 N. Boylan Avenue
Raleigh, NC 27603
P (919) 828.0577
F (919) 828.3899
C (919) 815.9377
www.smithgardnerinc.com
/ �/ 11 /� / �_ � � G ��/ // // / / �/ 2 ° / / / � / /// // / / / / ✓// y
_ / N
CAR ''•.
LDocu Signed by: ;Q SEAL'v_•
5MB31996A674D700.021666
INE��. �v
�F,�
TF .......
sell Ots
8/20/2021
,J,� „ (SEE REfTRENCE 1)
PROPOSED 10' CONTOUR
-200
CID
_ \
_ o
/ 705
_
PROPOSED 2' CONTOUR
\ \ — LIMITS OF LINER (PHASE 6A)
� z
\ \ _ LIMIT OF LINER
\ > \ a (EXISTING LINED UNITS)
NOTE
1. GRADES SHOWN FOR PHASE 6A REPRESENT TOP OF
-;;20j INTERMEDIATE COVER GRADES.
J I i '►go-
1 %X
'y"— REFERENCES
1. OVERALL SITE TOPOGRAPHY PROVIDED BY GEODATA
CORPORATION, BASED ON MAY 5, 2020 AERIAL
PHOTOGRAPHY.
0 200' 400'
z
W
0o Z
J o
z�7i
Q
U o
U
-
c U
N
m
Z
u'
Ln
00
Co
Co
m
w
Z
Z Z
w
J
o
cn C.
cn z
Q o
z N
�z
U =
cn W
1 � �
CV
O
N
Z3
du Q
21 Smith G rdner, Inc.
Volume
Base Surface TOPO-052420—PCVR-6A—PASTE
Comparison Surface TOW—CELL6A
/—
! o / / / I I I I 1 / III 111 I / � / / // / �/ / \ �\\ \\�\ � \ \ � \ ✓ /� j / / \ .. / /�� �� /� � — — Cut volume (unadjusted) 601.41 Cu. Yd.
Fill volume (unadjusted) 1,042,158.19 Cu. Yd.
Net volume (unadjusted) 1,041,556.78 Cu. Yd.<Fill>
/ \ \
\\\
,X
240
IIIINIIII=�-- _
\ \ \ // \/=� � \ ll� III II — _--___—�/ /� ////' � �/�� � ;�'— — _ ��\\ � ��I► IIII II// / /_
130�`
\\\�I
I►mil/I/o Illl ,11 11 III
\ II I 1 v
IIII illl"jl �II11
III IIII III .II 1
I 1
0
_ 220
560
0 77-
210
21\\\\\\ \\
r.3 \ \\ \\ \ \\�� \\\ o1b' \\\ \
\ \ _ _ \\ \ 210—
\
0 150' h 300'