Loading...
HomeMy WebLinkAbout4116_Guilford_WI_GFL_HighPoint_CDLF_LFG_FID1611567_202109304 wr GF r PEEN FOR LIFE environmental September 30, 2021 Ms. Jaclynne Drummond, Hydrogeologist Department of Environmental Quality, Division of Waste Management, Solid Waste Section 2090 US Highway 70 Swannanoa, North Carolina 28778 jaclynne.drummond@ncdenr.gov RE: METHANE MONITORING RESULTS — SEPTEMBER 2021 MONTHLY EVENT WI HIGH POINT CONSTRUCTION AND DEMOLITION LANDFILL AND RECLAMATION FACILITY, PERMIT NO. 41-16 Dear Ms. Drummond, WI High Point Landfill, LLC, is submitting the enclosed monthly methane monitoring results for the September 2021 monthly methane monitoring event at the above -referenced facility. If you have any questions, please contact me at (724) 244-9511. Sincerely, WI High Point Landfill, LLC Joseph Santangelo Regional Environmental Compliance Manager Enclosure C: Dusty Reedy, PG, Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, North Carolina, 27407, 336-852-4903, dreedy@golder.com Travis Hitchcock, 3301 Benson Drive, Raleigh, North Carolina, 27609. (travis.hitchcock@gflenv.com), (letter only). Bryan Wuester, Regional Landfill Manager, 7434 Roseboro Highway, Roseboro, Sampson County, North Carolina 28382, Bryan.Wuester@gflenv.com Seth Heath, General Manager,5830 Riverdale Drive, Jamestown, North Carolina 27282, seth.heath@gflenv.com, 336-886-3560 1236 Elon Place High Point NC, 27263 Tel.: 336-668-3712 Fax: 336-482-3061 1 gflenv.com GOLDER MEMBER OF WSP September 28, 2021 Joseph Santangelo, Regional Environmental Compliance Manager GFL Environmental Inc. 1192 McClellandtown Road McClellandtown, Pennsylvania 15458 joseph.santangelo@gflenv.com Project No. 2013788121.702 METHANE MONITORING RESULTS — SEPTEMBER MONTHLY EVENT FOR 2021 WI HIGH POINT CONSTRUCTION AND DEMOLITION LANDFILL AND RECLAMATION FACILITY, PERMIT NO. 41-16 Dear Joe, Attached are the results from the September 20, 2021, monthly methane monitoring at the above -referenced facility for your files. As shown on the attached Landfill Gas Monitoring Data Form, methane was not detected above the lower explosive limit (LEL) at any compliance monitoring point. A Landfill Gas Remediation Plan (LFGRP) was submitted to the North Carolina Department of Environmental Quality (NC DEQ) by Smith+Gardner on July 26, 2021 and was approved by the NC DEQ on August 2, 2001. As proposed in the LFGRP, the installation of vent in the berm adjacent to LFG-2A and re -grading the area to promote better drainage began on July 23, 2001. Golder installed two additional vents were in the vicinity of LFG- 2A on September 13, 2021 and a report documenting that effort is in progress. If you have any questions or concerns, please contact us at 336 852-4903. Sincerely, Golder Associates NC, Inc. r ,r David "Dusty" Y. Reedy II, PG Senior Hydrogeologist Golder Associates NC, Inc. 5B Oak Branch Drive, Greensboro, North Carolina, USA 27407 04, Rachel P. Kirkman, PG Principal and Senior Consultant Engineering Lic. No. C-2862/Geology Lic. No. C-399 Golder Associates NC, Inc. is a licensed user of the Golder trademark, and an associated operating entity. T: +1 336 852-4903 F: +1 336 852-4904 Golder and the G logo are trademarks of Golder Associates Corporation. golder.com Joseph Santangelo, Regional Environmental Compliance Manager GFL Environmental Inc. Project No. 2013788121.702 September 28, 2021 CC: Seth Heath, General Manager,5830 Riverdale Drive, Jamestown, NC 27282, seth.heath@gflenv.com, 336-886-3560 Bryan Wuester, Regional Landfill Manager, GFL Environmental, 7434 Roseboro Highway, NC 28382, bryan.wuester@gflenv.com (Electronic Copy) Travis Hitchcock, Region Vice President, GFL Envrionmental, 3301 Benson Drive, Suite 601, Raleigh, NC, 27609, travis.hitchcock@gflenv.com. (Electronic Copy) Attachments: Landfill Gas Monitoring Data Form — September 20, 2021 Site Location Map Calibration Forms aaEL R NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statue 132-1. As such. these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Permit Number: Waste Industries of High Point C&D Landfill 41-16 Sampling Date:_09/20/2021 Landfill Rule (.0500 or.1600): •0500 Sample Collector Name & Position: Ni ©las Tejeda-Torres, Geologist Gas Meter Type & Serial Number: GEM 5000 Gas Meter Calibration Date: 07/30/2021 Field Calibration Date & Time: 09/20/2021; 11:46 Field Calibration Gas Type (15115 or 35/50):_1 5/1 5 Field Calibration Gas Canister Expiration Date: 10/29/2024 Gas Meter Pump Rate: 300 cc/min Ambient Air Temperature: 79O F Barometric Pressure (in. or mm Hg): 29.22" Weather Conditions: Cloudy, winds SE 9mph Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location man or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and'or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) °Initial /° LEL Stabilized /° LEL % CH4 (volume) % 02 (volume) % CO2 (volume) %H2S* (volume) NOTES Scalehouse 12:48 90 0.0 0.0 0.0 20.2 0.1 0.0 Maintenance 12:44 90 0.0 0.0 0.0 20.4 0.0 0.0 Break Room 12:52 90 0.0 0.0 0.0 20.3 0.0 0.0 LFG-1 13:12 90 0.0 0.0 0.0 19.9 0.1 0.0 Pressure:0.01 LFG-2 13:18 90 0.0 0.0 0.0 17.7 2.8 0.0 LFG-2A 13:21 90 24.0 24.0 1.2 16.9 2.9 0.0 Pressure: -0.01 LFG-3 13:00 90 1 0.0 0.0 1 0.0 15.0 9.1 1 0.0 Pressure:0.02 LFG-4 12:55 90 0.0 0.0 0.0 20.1 0.0 0.0 Pressure:0.04 LFG-5 13:07 90 0.0 0.0 0.0 17.0 3.2 0.0 Pressure:0.01 NOTE: If needed. attach additional data forms to inchide additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or includin the possibility of a fine and imprisonment. Senior Hydrogeologist SIGNATU TITLE Revised - March 6, 2017 •�: '0 0L 0�q 09 1110 :• ��- �;• INN X. LFG-2 EXCAVATION 2 I RECLAMATION LFG-4 \ \ FACILITY � \ � MW-1 S �-740F /j 77 Mw 0 101 O SCALE FEET NT WIHIGHPOINT LANDFILL, LLC 4 //coNsuLrnn* YYYY-MM-DD 2021-09-23 i PREPARED BPG G 0 L D E R / DESIGN DYR MEMBER OF WSP REVIEW DYR GOLDER ASSOCIATES NC, INC. APPROVED RPK 24 F�'ayu�ar'f&- • r - -� � - Q0, SITE LOCATION �'�`.tq`< L .. .. 6 O SITE LOCATION MAP LEGEND EXISTING 10' CONTOURS EXISTING 2' CONTOURS — — PROPERTY LINE STREAM / DRAINAGE FEATURE �F TREELINE EXISTING ROAD — — — — — PROPOSED OR EXISTING LIMITS OF WASTE - MW-3 MONITORING WELL LOCATION ❑ SW-1 SURFACE WATER MONITORING POINT LFG-1 LANDFILL GAS MONITORING WELL LOCATIONS ® BM-1 BENCH MARK SB-1 SEDIMENT BASIN 0 GAS VENT EXCAVATION NOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET 2. DRAWING BASED ON SITE PLAN PLAN PREPARED BY JOYCE ENGINEERING, INC DATED J U LY 7, 2004. 3. UPDATED TOPOGRAPHY IN VICINITY OF LANDFILL PROVIDED FROM AERIAL SURVEY PREPARED BY COOPER AERIAL SURVEY COMPANY, DATE JANUARY 6, 2021. PROJECT WI HIGH POINT CONSTRUCTION AND DEMOLITION DEBRIS LANDFILL AND RECLAMATION FACILITY GUILFORD COUNTY, NORTH CAROLINA TITLE METHANE MONITORING LOCATION MAP PROJECT No. Rev. DRAWING 2013788121 0 1 c i c L 0 ENR®-EQUIPMENT, INC. LANDTEC GEM 5000 Plus CALIBRATION DATA SHEET ` Serial Number_a,5(2)gi0(5 Date_ Inspector_ Time/Date '� Battery Level. Memory Cleared '� Pump Faults Gas Alarms: CHQ = 100.0% CO2 = 100.0% 02 = 22.0% Zero Transducers Pump Flow Rate'" W l !l-1 c Gl r,�: ri Vacuum Tested To 80" H2O Calibration Check (Performed at Room Temperature) Calibration Gas Calibration Gas Lof Number Expiration Concentration " Pure N2 %1Ci.9Czq-Y. Q - 4 High CH, High CO2 Low CH4 5/ 0 12(p -- Low CO2 I2J2 2 eo �Z�O Low 02 L�)' tta ct(01 A High 02 20.9%.. N/A- N/A H2S 2) Reading Accurac)1* W/. ./ t 2% t 2% f 2% t—t' j - s 2% Y. 10% «� f 10% 'Accuracy depends upon calibration range; 15%-FS range for CH, & CO2, 0-5% volume for Q, 0%-FS for H2S, and 10% of reading f'or CO. INSPECTOR'S MAINTENANCE NOTES EEI GEM 2000 Plus Cal Form 01/12 - - - Callbrallon No. 66916 ` Date Of Calibration: 30-Jul-2021 Certificate Number: G504615_10/4.2235 Customer: Enviro Equipment Inc 11180 Downs Rd Pineville, NC-28134 USA rDescription: Landtec Gas Analyzer Model: GEM5000 - Serial Number. G504615 Accredited Results: ,. Methane IrHat< Certified Gas °� Instrument Readin % Uncertainty 5.0 4'.9 . :.0.42 15.0 15.0 0.66..._ 50 0 1.03' F -Carbon Dioxide CO2 • Certified Gas °.6 ' Instrument Reading(% ' Uncertaint .5.0 4.9 0;43 15.0 ' 14:8'. 0.71' -50.0 ' - .• — -50.5 1.19 U en Q2 Certified Gas C% Instrument Reading% Uncertainty_ ' 20.5 20.5 0:25 - Gas cylinclers'are traceable and details can be provided if ' requested. CH4, CO2 readings recorded at:-31.6'C/88.8 °F •$�arometric Pressure: 0985 mbar/29.09 "jig 02 readings recorded at: 22:2 "C/72.0 °F Method of Test,: The analyzer is calibrated in-�a temperature controlled chamber using a series of reference gases, in compliance with procedure ISP17. ` The reported expanded uncertainly is. based on a standard uncertaintyemultiplied by a coverage factor of k=2, providing a level of confidence' of approximately 95%. The-uncertointy evaluation has been carried out in accordance with. NI.TF requirements. - The calibration results published in this certificate were obtained using equipment capable of produci�gresults that are traceable through NIST to the International System of Units IS11. Certification only applies to. results Shbwri: This certificate may not be reproduced other th'aa-4n full, except with the prior written approval of the issuing laboratory. Calibration Instance: 112 10t. Instance: 112 - Page I of 211.110151.NANIST-I.I ti ♦. PJLA Calibration y _ No. 66916 Date Of Calibration: ,4L30-Jul-2021 Certificate Number: G504615_10/42235 Non Accredited results: • - Pressure Transducers inches of water column Transducer Certified (Low) Reading (Low) Certified (High) Reading (High) Accuracy Static 0" 0" 40" T 40.10" 2.0" Differential 0" Or' 4" 4.01" 0.7" Barometer (mbar) Reference Instrument Reading 0985 mbar 29.09 "Hg 0985 mbar 29.09 "Hig As received gas check readkigs:. Methane CH4 Certified Gas %Y Instrument Reading % _ . 5.0 4.9 .. 14.9. . 50.0 " 49.1 - Carbon Dioxide CO2 rtifieil Gas. °.6) Instrument Readin% - _ 5.0 -•' 4.9 15.0 _ 15.1 s. 50.0 50.2' '4 - Oxygen 02 Certifidd Gas Instrument Readi 20.5 20.9' - As received Gas readings recorded at: 31.6 "C/88.8 °F As received Barometric Pressure recorded at: 22.2 °C/72.0 °F - «_ As received gas check readings are only recorded if the instrument is rece da in a wo king conditi y Where the instrument is received'darnaged ne reading can betaken Date of Issue : 02 Aug 2021 Approved By Signatory Kyle Racine l.aboratorylnspection rite , Lion result; it ri,i ie., t ate were obtained using equipm2e,: capabir •.;!producing resu:is chit . ,Crate;: le o 5';' t•� the Intcr,4tiorral System of r iAiis -511. Certification ("My apl,fcs to•resu;r; shown.. This certificate may not be reQrncic:ct' other than infull, -ace,. �•ah ;h; {no:. c' ; ;,pineal of ttre issuing, lat;o, ory. 12 .. �; - aw ' !� > ni' i. LWJI : NANISI . 1 .Sr _ r � s