Loading...
HomeMy WebLinkAboutSDTF8304_INSP_20210924FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 2 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Scotland Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: SDTF 83-04 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF X FILE TYPE: COMPLIANCE Date of Site Inspection: 9/24/2021 Date of Last Inspection: 4/26/2021 FACILITY NAME AND ADDRESS: Cooper Septic Tank Service P.O. Box 645 Wagram, NC 28396 GPS COORDINATES: N: 34.80737 E: -79.36842 FACILITY CONTACT NAME AND PHONE NUMBER: Name: Emily & Randy Cooper Telephone: (910) 369-2713 Email address: coopere41@gmail.com Fax: (910) 369-2295 FACILITY CONTACT ADDRESS: 387 S. Hilltop Road Red Springs, NC 28377 PARTICIPANTS: Connie Wylie, Emily Cooper STATUS OF PERMIT: Active – permit expires July 7, 2022 PURPOSE OF SITE VISIT: Routine STATUS OF PAST NOTED VIOLATIONS: N/A OBSERVED VIOLATIONS: N/A SEE BACK OF PAGE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 ADDITIONAL COMMENTS 1. The tank appears structurally sound. 2. The approved setbacks are being met. 3. The required signs are posted and the access road is adequate. 4. It appears that septage is being transferred to/from the facility in a safe and sanitary manner. No spills or leaks noted. No apparent vectors or odors. The tank is used occasionally. 5. The required 5 foot cleared radius (free of excess vegetation or debris) shall be maintained on all sides of the tank. 6. If any firm other than Cooper Septic Tank Service will be utilizing this storage tank then an authorization form shall be submitted yearly and also a copy of the detention logs shall be submitted monthly. Please contact me if you have any questions or concerns regarding this inspection report. _ Phone: (910) 433-3352 Connie S. Wylie Regional Representative Sent on: Email Hand delivery X US Mail Certified No. [ _]