HomeMy WebLinkAboutMO-28738_47974_CA_CLO_20210729_UST In-Place Abandonment ReportCedar Rock
ENVIRONMENTAL
July 29, 2021
Ms. Jessica Parker
212 W. Friendly Avenue
Greensboro, NC 27401
CEDAR ROCK ENVIRONMENTAL, P.C.
107 Pioneer Trail
Graham, NC 27253
(336) 376-0394
RE: Underground Storage Tank (UST) Closure Assessment Report
6342 Deveron Drive, Charlotte, North Carolina
Cedar Rock Project Number 325222590
Dear Ms. Parker:
Cedar Rock Environmental, P.C. (Cedar Rock) is pleased to submit this report describing activities
and results for the in -place abandonment of the onsite UST located at 6342 Deveron Drive in
Charlotte, North Carolina. The UST abandonment was performed on July 29, 2021. Included in
this report are project documents consisting of a disposal manifest and photographic
documentation. This report should be kept with other documents pertaining to the residential
property.
Soil contamination was detected beneath the UST during a site inspection performed on July 21,
2021. The release was reported to the Department of Environmental Quality (DEQ) using a UST-
61 form on July 22, 2021. Although the State no longer requires further assessment of the
contamination, the State does require the filing of a Notice of Residual Petroleum (NRP) prior to
conveying the property to another party. The NRP includes land use restrictions prohibiting any
disturbance of site soils within a specified radius of the estimated extent of soil contamination and
prohibits the use or installation of any water supply wells on the property. Cedar Rock filed the
NRP on July 27, 2021. The DEQ will issue a Conditional Notice of No Further Action (NFA)
letter within the next few days. Upon receipt of proof that the local officials and adjacent property
owners have been notified of the release by receiving a copy of the Conditional NFA letter, and
that the NRP has been filed, the DEQ will reissue the NFA letter with no conditions to officially
close out the petroleum release incident.
Enclosed is an invoice for this work effort. If you have any questions, please do not hesitate to
contact me at 336-376-0394. Thank you for your consideration of Cedar Rock to provide you with
this service.
Sincerely,
Robert A. Payne, Z.G.
President
RAP:rp
Attachments
UNDERGROUND STORAGE TANK
CLOSURE ASSESSMENT REPORT FOR
6342 DEVERON DRIVE
CHARLOTTE, NORTH CAROLINA
Prepared for:
Ms. Jessica Parker
Greensboro, North Carolina
Prepared by:
Cedar Rock Environmental, P.C.
107 Pioneer Trail
Graham, North Carolina
Robert A. Payne, L.G.
President
July 29, 2021
CR #325222590
Section
TABLE OF CONTENTS
1.0 INTRODUCTION
2.0 PROJECT
FIGURE
Site Map
APPENDICES
A Fluid Disposal Manifest
B Photographic Documentation
Page No.
I hereby certify this 29th day of July 2021 that this report was prepared by me or under my direct
supervision.
Robert A. Payne, L.G
Geologist
ii
1.0 INTRODUCTION
Cedar Rock Environmental, P.C. (Cedar Rock) was contacted by Ms. Jessica Parker of
Greensboro, North Carolina to abandon in -place an underground storage tank (UST) located at
6342 Deveron Drive in Charlotte, North Carolina. The UST was first inspected on July 21, 2021.
An inactive UST was observed to be located perpendicular to and centered approximately 9.6 feet
off the southeastern foundation wall and about 40.0 feet northeast of the south foundation corner
of the house (see Site Sketch). Both the fill and vent pipes to the UST were observed to be intact.
The depth to the top of the UST is approximately 29 inches below land surface (bls). The UST
has an estimated length of about 75 inches with a diameter of approximately 44.75 inches and an
estimated capacity of about 550 gallons. The tank was measured to contain approximately 170
gallons of fluid. White flagging was installed to mark the ends of the UST (see Photo). No other
USTs used for storing heating oil were discovered on the property using a metal detector to survey
the outside perimeter of the residence where USTs are usually located. Two copper fuel
delivery/return lines were observed in the basement/crawlspace extending about 1.5 feet off the
foundation wall adjacent to the UST where they were cut and crimped closed. No petroleum odors
or stains were observed in the basement/crawlspace; however, plastic was lining the floor which
limited the inspection.
Once the orientation of the UST was determined, a soil boring was performed at the southeastern
end of the tank using a 3.25-inch diameter stainless steel hand auger. The boring was advanced to
a depth of approximately 5.5 feet bls, about 0.6 feet above the bottom of the UST. A strong
petroleum odor and discoloration was observed in the soils from a depth of approximately 5.0 to
5.5 feet bls suggesting significant leakage from the UST has occurred. The soils at the base of the
boring consist of a grayish blue sandy silt.
2.0 PROJECT
The in -place abandonment of the UST was performed on July 29, 2021. The abandonment
consisted of the hand excavation of the soils overlying the northwestern end of the UST to expose
the topside of the tank. A hole approximately 1.5 feet in diameter was then cut on the top of the
UST to allow for removal of the tank contents, cleaning and visual inspection of the UST interior,
and subsequent filling. The tank was pressure washed to remove all residual petroleum sludge.
Residual oil in the fuel lines was also removed by vacuum. The fuel lines were removed from the
basement area. Approximately 200 gallons of fluid and sludge (including rinsate) were removed
from the UST. The fluid disposal manifest for the tank contents is included in Appendix A.
After the interior of the UST was cleaned, the tank was then entirely filled with an excavatable
flowable fill cement slurry. Once filled, the exposed portion of the UST was then covered with
site soils (see Appendix B - Photographic Documentation).
1
FIGURE
SITE MAP
0 10 20 40
T1 = 550-Gallon UST
1 Inch = 20 Feet
PROJECT: Saville Parker Property
INCIDENT # Pending
LOCATION: 6342 Deveron Drive
Charlotte, Mecklenburg Co.
CRE PROJECT NUMBER: 325222590
CEDAR ROCK
ENVIRONMENTAL, P.C.
FILENAME: 3252-Fig1.fc7
VERSION DATE: 7/22/21
SITE MAP
FIGURE 1
APPENDIX A
FLUID DISPOSAL MANIFEST
MATERIAL
MANIFEST
EMERGENCY PHONE NO.
(336)841-5276
_—bra
tnvaann,aaa+s eausnw swwG��
Manifest Document No.
Page of
POST OFFICE BOX 357 TEL (336) 841-5276 Zebra Job No.
HIGH POINT, NC 27261 FAX (336) 841-5509
GENERATOR INFORMATION
Name US EPA ID No.
Street Address Mailing Address Phone No.
Contact
DESCRIPTION OF MATERIALS
USDOT Proper Shipping Name
HMI (Complete All Items for Hazardous Materials)
Hazard
Class or Div
UN / NA
ID No.
Packing
Group
Containers
Qty. Type
Total
Quantity
Unit
Wt./Vol.
a.
b.
C.
ADDITIONAL INFORMATION
ERG No.
Zebra Profile Code
Facility Use
a.
b.
C.
GENERATOR'S CERTIFICATION
This is to certify that the above -described materials are properly classified, described, packaged, marked and labeled, and are in
proper condition for transportation according to the applicable regulations of the Department of Transportation. / further certify that
none of the materials described above are a hazardous waste as defined by EPA 40 CFR Part 261 or any applicable state law, and
unless specifically identified above, the materials contain less than 1, 000 ppm total halogens and do not contain quantifiable levels
(2 ppm) of PCBs as defined by EPA 40 CFR Parts 279 and 761.
TRANSPORTER
INFORMATION
Transporter Zebra Environmental & Industrial Services Inc
I hereby acknowledge receipt of the above -described materials for transport
from the generator site listed abgve.
Address
901 East Springfield Road
--
High Point, NC 27263
Signature Shipment Date
I hereby acknowledge receipt of the above -described materials were received
from the generator site and were transported to the facility listed below.
or NC0991302669
Uri i�la,
i
EPA ID Nter
j/ /
Signature Delivery Date
Phone (336) 841-5276
FACILITY INFORMATION
Facility Zebra Environmental & Industrial Services, Inc.
I hereby acknowledge receipt of the materials covered by this manifest
except for any discrepancy noted below.
Address
901 East Springfield Road
High Point, NC 27263
Signature Receipt Date
Discrepancies / Routina Codes / Handina Methods
Facility or NC0991302669
EPA ID No.
a.
Phone
(336) 841-5276
b.
Contact gill Hunter
C.
ORIGINAL - Facility Retain COPY 2 - Return to Generator COPY 3 - Transporter Retain COPY 4 - Generator Retain
APPENDIX B
PHOTOGRAPHIC DOCUMENTATION
Photo 1. View of the UST site prior to abandonment activities.
•
s ' 07
f s
� �''• �-�'� , bar �, .� � ��� "- • ''
f
V ti
s
4
Photo 2. View of the UST interior prior to the removal of tank contents.
r
f
3
Photo 3. View of the UST interior after the removal of UST contents and
pressure wash cleaning of the tank interior.
Photo 4. View of the UST being filled with flowable fill cement slurry.
"tea
tilt; -
y
F:
Photo 5. View of the UST after filling with flowable fill cement slurry.
Photo 6. View of the UST site after the completion of abandonment activities.
Beverly, Trudy
From: Beverly, Trudy
Sent: Thursday, August 19, 2021 12:04 PM
To: Josiah Payne; Bob Payne; damienkc@bellsouth.net
Subject: RE: [External] Re: Revocable Trust of Sharon Saville Parker Property Tank Closure Report
Thank you for sending the report and contact information.
Trudy
Trudy Beverly, L.G.
F5 Hydrogeologist, Division of Waste Management
cc�.�DFNorth Carolina Department of Environmental Quality
r"c 1°" � UST Section, Mooresville Regional Office
ry om�`
704.235.2182 (Office)
Trudy.Beverlykncdenr. gov
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.
Office Mailing Address:
610 East Center Avenue, Suite 301
Mooresville, NC 28115
Branch's Underground Storage Tanks Website Address: ht_pt s://deg.nc.gov/about/divisions/waste-management/ust
Branch's Above Ground Storage Tanks Website Address: hgps:Hdeg.nc.gov/about/divisions/waste-management/ust/ast-program
INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES:
httns://deu.nc. gov/about/divisions/waste-management/waste-management-rules-data/waste-management-gis-mans
File Review Procedures:
ht_pt s://deq.nc.gov/about/divisions/waste-management/ust/file-review-procedures#mooresville-regional-office
ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche):
htt2s://deg.nc.gov/about/divisions/waste-mana2ement/laserfiche
Document Submittal & UST File Names for Laserfiche Policies:
httys:Hfiles.nc.eov/nedea/Waste%2OMana2ement/DWM/UST[WhatsNew/Final-Electronic-Document-Submittal-Policy.odf
https:Hfiles.nc.gov/ncdeg/Waste%2OManagement/D WM/UST/Corrective%2OAction/UST%20file%20names%20for%2OLaserfiche.docx
From: Josiah Payne [mailto:josiah.cre@gmail.com]
Sent: Thursday, August 19, 2021 11:59 AM
To: Beverly, Trudy <trudy.beverly@ncdenr.gov>; Bob Payne <cedarrockenv@gmail.com>; damienkc@bellsouth.net
Subject: [External] Re: Revocable Trust of Sharon Saville Parker Property Tank Closure Report
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to
Report Spam.
I have attached a copy of the abandonment report.
Jessica's email is thenewjessiekicloud.com
Josiah
On August 19, 2021 11:48:36 "Beverly, Trudy" <trudy.beverly(@ncdenr.gov> wrote:
Hey Bob, Josiah, & Damien,
I haven't received a tank closure report for Revocable Trust of Sharon Saville Parker Property located at 6342 Deveron
Drive, Charlotte. Please email me a copy when available. Do you have an email address for Jessica Parker?
Thank you,
Trudy
Trudy Beverly, L.G.
Hydrogeologist, Division of Waste Management
North Carolina Department of Environmental Quality
UST Section, Mooresville Regional Office
704.235.2182 (Office)
Trudv.Beverlvna,ncdenr. eov
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.
Office Mailing Address:
610 East Center Avenue, Suite 301
Mooresville, NC 28115
Branch's Underground Storage Tanks Website Address: https:Hdeg.nc.gov/about/divisions/waste-management/ust
Branch's Above Ground Storage Tanks Website Address: htips:Hdeg.nc.gov/about/divisions/waste-management/ust/ast-program
INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES:
httr)s:Hdeu.nc. eov/about/divisions/waste-manaeement/waste-manaeement-rules-data/waste-manaeement-eis-mans
File Review Procedures:
hit 2s://deq.ne. gov/about/divisions/waste-manaaement/ust/file-review-procedures#mooresville-regional-office
ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche):
httDs:Hdea.nc. eov/about/divisions/waste-manaeement/laserfiche
Document Submittal & UST File Names for Laserfiche Policies:
htti)s://files.nc.Eov/ncdea/W aste%20Manauement/D WM/UST/W hatsNew/Final-Electronic-Document-Submittal-Policy.udf
https://fi les.nc. gov/ncdeq/Waste%20Management/D WM/UST/Corrective%2OAction/UST%2Ofile%20names%20for%2OLaserfiche. docx