Loading...
HomeMy WebLinkAboutMO-28738_47974_CA_CLO_20210729_UST In-Place Abandonment ReportCedar Rock ENVIRONMENTAL July 29, 2021 Ms. Jessica Parker 212 W. Friendly Avenue Greensboro, NC 27401 CEDAR ROCK ENVIRONMENTAL, P.C. 107 Pioneer Trail Graham, NC 27253 (336) 376-0394 RE: Underground Storage Tank (UST) Closure Assessment Report 6342 Deveron Drive, Charlotte, North Carolina Cedar Rock Project Number 325222590 Dear Ms. Parker: Cedar Rock Environmental, P.C. (Cedar Rock) is pleased to submit this report describing activities and results for the in -place abandonment of the onsite UST located at 6342 Deveron Drive in Charlotte, North Carolina. The UST abandonment was performed on July 29, 2021. Included in this report are project documents consisting of a disposal manifest and photographic documentation. This report should be kept with other documents pertaining to the residential property. Soil contamination was detected beneath the UST during a site inspection performed on July 21, 2021. The release was reported to the Department of Environmental Quality (DEQ) using a UST- 61 form on July 22, 2021. Although the State no longer requires further assessment of the contamination, the State does require the filing of a Notice of Residual Petroleum (NRP) prior to conveying the property to another party. The NRP includes land use restrictions prohibiting any disturbance of site soils within a specified radius of the estimated extent of soil contamination and prohibits the use or installation of any water supply wells on the property. Cedar Rock filed the NRP on July 27, 2021. The DEQ will issue a Conditional Notice of No Further Action (NFA) letter within the next few days. Upon receipt of proof that the local officials and adjacent property owners have been notified of the release by receiving a copy of the Conditional NFA letter, and that the NRP has been filed, the DEQ will reissue the NFA letter with no conditions to officially close out the petroleum release incident. Enclosed is an invoice for this work effort. If you have any questions, please do not hesitate to contact me at 336-376-0394. Thank you for your consideration of Cedar Rock to provide you with this service. Sincerely, Robert A. Payne, Z.G. President RAP:rp Attachments UNDERGROUND STORAGE TANK CLOSURE ASSESSMENT REPORT FOR 6342 DEVERON DRIVE CHARLOTTE, NORTH CAROLINA Prepared for: Ms. Jessica Parker Greensboro, North Carolina Prepared by: Cedar Rock Environmental, P.C. 107 Pioneer Trail Graham, North Carolina Robert A. Payne, L.G. President July 29, 2021 CR #325222590 Section TABLE OF CONTENTS 1.0 INTRODUCTION 2.0 PROJECT FIGURE Site Map APPENDICES A Fluid Disposal Manifest B Photographic Documentation Page No. I hereby certify this 29th day of July 2021 that this report was prepared by me or under my direct supervision. Robert A. Payne, L.G Geologist ii 1.0 INTRODUCTION Cedar Rock Environmental, P.C. (Cedar Rock) was contacted by Ms. Jessica Parker of Greensboro, North Carolina to abandon in -place an underground storage tank (UST) located at 6342 Deveron Drive in Charlotte, North Carolina. The UST was first inspected on July 21, 2021. An inactive UST was observed to be located perpendicular to and centered approximately 9.6 feet off the southeastern foundation wall and about 40.0 feet northeast of the south foundation corner of the house (see Site Sketch). Both the fill and vent pipes to the UST were observed to be intact. The depth to the top of the UST is approximately 29 inches below land surface (bls). The UST has an estimated length of about 75 inches with a diameter of approximately 44.75 inches and an estimated capacity of about 550 gallons. The tank was measured to contain approximately 170 gallons of fluid. White flagging was installed to mark the ends of the UST (see Photo). No other USTs used for storing heating oil were discovered on the property using a metal detector to survey the outside perimeter of the residence where USTs are usually located. Two copper fuel delivery/return lines were observed in the basement/crawlspace extending about 1.5 feet off the foundation wall adjacent to the UST where they were cut and crimped closed. No petroleum odors or stains were observed in the basement/crawlspace; however, plastic was lining the floor which limited the inspection. Once the orientation of the UST was determined, a soil boring was performed at the southeastern end of the tank using a 3.25-inch diameter stainless steel hand auger. The boring was advanced to a depth of approximately 5.5 feet bls, about 0.6 feet above the bottom of the UST. A strong petroleum odor and discoloration was observed in the soils from a depth of approximately 5.0 to 5.5 feet bls suggesting significant leakage from the UST has occurred. The soils at the base of the boring consist of a grayish blue sandy silt. 2.0 PROJECT The in -place abandonment of the UST was performed on July 29, 2021. The abandonment consisted of the hand excavation of the soils overlying the northwestern end of the UST to expose the topside of the tank. A hole approximately 1.5 feet in diameter was then cut on the top of the UST to allow for removal of the tank contents, cleaning and visual inspection of the UST interior, and subsequent filling. The tank was pressure washed to remove all residual petroleum sludge. Residual oil in the fuel lines was also removed by vacuum. The fuel lines were removed from the basement area. Approximately 200 gallons of fluid and sludge (including rinsate) were removed from the UST. The fluid disposal manifest for the tank contents is included in Appendix A. After the interior of the UST was cleaned, the tank was then entirely filled with an excavatable flowable fill cement slurry. Once filled, the exposed portion of the UST was then covered with site soils (see Appendix B - Photographic Documentation). 1 FIGURE SITE MAP 0 10 20 40 T1 = 550-Gallon UST 1 Inch = 20 Feet PROJECT: Saville Parker Property INCIDENT # Pending LOCATION: 6342 Deveron Drive Charlotte, Mecklenburg Co. CRE PROJECT NUMBER: 325222590 CEDAR ROCK ENVIRONMENTAL, P.C. FILENAME: 3252-Fig1.fc7 VERSION DATE: 7/22/21 SITE MAP FIGURE 1 APPENDIX A FLUID DISPOSAL MANIFEST MATERIAL MANIFEST EMERGENCY PHONE NO. (336)841-5276 _—bra tnvaann,aaa+s eausnw swwG�� Manifest Document No. Page of POST OFFICE BOX 357 TEL (336) 841-5276 Zebra Job No. HIGH POINT, NC 27261 FAX (336) 841-5509 GENERATOR INFORMATION Name US EPA ID No. Street Address Mailing Address Phone No. Contact DESCRIPTION OF MATERIALS USDOT Proper Shipping Name HMI (Complete All Items for Hazardous Materials) Hazard Class or Div UN / NA ID No. Packing Group Containers Qty. Type Total Quantity Unit Wt./Vol. a. b. C. ADDITIONAL INFORMATION ERG No. Zebra Profile Code Facility Use a. b. C. GENERATOR'S CERTIFICATION This is to certify that the above -described materials are properly classified, described, packaged, marked and labeled, and are in proper condition for transportation according to the applicable regulations of the Department of Transportation. / further certify that none of the materials described above are a hazardous waste as defined by EPA 40 CFR Part 261 or any applicable state law, and unless specifically identified above, the materials contain less than 1, 000 ppm total halogens and do not contain quantifiable levels (2 ppm) of PCBs as defined by EPA 40 CFR Parts 279 and 761. TRANSPORTER INFORMATION Transporter Zebra Environmental & Industrial Services Inc I hereby acknowledge receipt of the above -described materials for transport from the generator site listed abgve. Address 901 East Springfield Road -- High Point, NC 27263 Signature Shipment Date I hereby acknowledge receipt of the above -described materials were received from the generator site and were transported to the facility listed below. or NC0991302669 Uri i�la, i EPA ID Nter j/ / Signature Delivery Date Phone (336) 841-5276 FACILITY INFORMATION Facility Zebra Environmental & Industrial Services, Inc. I hereby acknowledge receipt of the materials covered by this manifest except for any discrepancy noted below. Address 901 East Springfield Road High Point, NC 27263 Signature Receipt Date Discrepancies / Routina Codes / Handina Methods Facility or NC0991302669 EPA ID No. a. Phone (336) 841-5276 b. Contact gill Hunter C. ORIGINAL - Facility Retain COPY 2 - Return to Generator COPY 3 - Transporter Retain COPY 4 - Generator Retain APPENDIX B PHOTOGRAPHIC DOCUMENTATION Photo 1. View of the UST site prior to abandonment activities. • s ' 07 f s � �''• �-�'� , bar �, .� � ��� "- • '' f V ti s 4 Photo 2. View of the UST interior prior to the removal of tank contents. r f 3 Photo 3. View of the UST interior after the removal of UST contents and pressure wash cleaning of the tank interior. Photo 4. View of the UST being filled with flowable fill cement slurry. "tea tilt; - y F: Photo 5. View of the UST after filling with flowable fill cement slurry. Photo 6. View of the UST site after the completion of abandonment activities. Beverly, Trudy From: Beverly, Trudy Sent: Thursday, August 19, 2021 12:04 PM To: Josiah Payne; Bob Payne; damienkc@bellsouth.net Subject: RE: [External] Re: Revocable Trust of Sharon Saville Parker Property Tank Closure Report Thank you for sending the report and contact information. Trudy Trudy Beverly, L.G. F5 Hydrogeologist, Division of Waste Management cc�.�DFNorth Carolina Department of Environmental Quality r"c 1°" � UST Section, Mooresville Regional Office ry om�` 704.235.2182 (Office) Trudy.Beverlykncdenr. gov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Office Mailing Address: 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Branch's Underground Storage Tanks Website Address: ht_pt s://deg.nc.gov/about/divisions/waste-management/ust Branch's Above Ground Storage Tanks Website Address: hgps:Hdeg.nc.gov/about/divisions/waste-management/ust/ast-program INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES: httns://deu.nc. gov/about/divisions/waste-management/waste-management-rules-data/waste-management-gis-mans File Review Procedures: ht_pt s://deq.nc.gov/about/divisions/waste-management/ust/file-review-procedures#mooresville-regional-office ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche): htt2s://deg.nc.gov/about/divisions/waste-mana2ement/laserfiche Document Submittal & UST File Names for Laserfiche Policies: httys:Hfiles.nc.eov/nedea/Waste%2OMana2ement/DWM/UST[WhatsNew/Final-Electronic-Document-Submittal-Policy.odf https:Hfiles.nc.gov/ncdeg/Waste%2OManagement/D WM/UST/Corrective%2OAction/UST%20file%20names%20for%2OLaserfiche.docx From: Josiah Payne [mailto:josiah.cre@gmail.com] Sent: Thursday, August 19, 2021 11:59 AM To: Beverly, Trudy <trudy.beverly@ncdenr.gov>; Bob Payne <cedarrockenv@gmail.com>; damienkc@bellsouth.net Subject: [External] Re: Revocable Trust of Sharon Saville Parker Property Tank Closure Report CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. I have attached a copy of the abandonment report. Jessica's email is thenewjessiekicloud.com Josiah On August 19, 2021 11:48:36 "Beverly, Trudy" <trudy.beverly(@ncdenr.gov> wrote: Hey Bob, Josiah, & Damien, I haven't received a tank closure report for Revocable Trust of Sharon Saville Parker Property located at 6342 Deveron Drive, Charlotte. Please email me a copy when available. Do you have an email address for Jessica Parker? Thank you, Trudy Trudy Beverly, L.G. Hydrogeologist, Division of Waste Management North Carolina Department of Environmental Quality UST Section, Mooresville Regional Office 704.235.2182 (Office) Trudv.Beverlvna,ncdenr. eov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Office Mailing Address: 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Branch's Underground Storage Tanks Website Address: https:Hdeg.nc.gov/about/divisions/waste-management/ust Branch's Above Ground Storage Tanks Website Address: htips:Hdeg.nc.gov/about/divisions/waste-management/ust/ast-program INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES: httr)s:Hdeu.nc. eov/about/divisions/waste-manaeement/waste-manaeement-rules-data/waste-manaeement-eis-mans File Review Procedures: hit 2s://deq.ne. gov/about/divisions/waste-manaaement/ust/file-review-procedures#mooresville-regional-office ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche): httDs:Hdea.nc. eov/about/divisions/waste-manaeement/laserfiche Document Submittal & UST File Names for Laserfiche Policies: htti)s://files.nc.Eov/ncdea/W aste%20Manauement/D WM/UST/W hatsNew/Final-Electronic-Document-Submittal-Policy.udf https://fi les.nc. gov/ncdeq/Waste%20Management/D WM/UST/Corrective%2OAction/UST%2Ofile%20names%20for%2OLaserfiche. docx