HomeMy WebLinkAboutMO-88838_96107_CA_O_20210824_MW-2 Groundwater Sample Results1%)
Lighthouse
Technical
August 24, 2021
Ms. Trudy Beverly
NCDEQ
610 East Center Avenue, Suite 301
Mooresville, North Carolina 28115
Re: Additional Assessment of well MW-2
Isgett Distributers -Used Oil Spill
January 8, 2021
Hilbish Ford
2600 South Cannon Boulevard
Kannapolis, North Carolina
Cabarrns County
Dear Ms. Beverly
Per your request on July 20, 2021, Lighthouse Technical returned to the site to collect a groundwater
sample from MW-2. The sample was collected on July 28, 2021, after bailing three well volumes of
water from the well with a disposable bailer. The sample was transferred to laboratory supplied
containers, transported on ice to Pace Analytical and analyzed for benzene by EPA method 6200B. The
laboratory analysis indicated Non -Detect results for benzene. A copy of the laboratory report is included
with this letter report. We recommend closure for the incident.
If you have questions about the data submitted, please contact us at 704-237-4209.
Sincerely,
Lighthouse Technical, P.C.
1
I'
Steven B. Lucas, L.G.
Environmental Geologist
cc Isgett Distributers
Environmental Consultants -Soil and Groundwater Specialists
Charlotte Roanoke Rapids
P.O. Box 1379, Huntersville, North Carolina 28070
Phone: (704) 237-4209 • www.lighthousetechcorp.com
Table 2
Summary of Analytical Results
Monitor Well Samples
Isgett Distribution Used Oil Spill
Hilbish Ford, Kannapolis, North Carolina
Analytical Method
EPA 6010D by EPA
Method 625
MADEP EPH
MADEP VPH
Method 6200
3010A
Aliphatic(
1,2,4-
1,3,5-
Constituent
Aliphatic
Aliphatic
Aromatic
Aliphatic
Aliphatic
Aromatic
Total
Chromium
Lead
All Compounds
C09-C12)
Trimethylb
Trimethylb
Benzene
Ethylbenzene
Toluene
of Concern
(C09-C18)
(C19-C36)
(C9-C22)
(C05-CO8)
(C09-C12)
(C09-C10)
Xylenes
Sample ID
Adjusted
enzene
enzene
Date
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
ug/L
Collected
M W-1
03/11/2021
19.1
5.2
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
4/26/2021
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
03/11/2021
28.1
33.0
ND
134
ND
ND
56.3
64.7
54.4
ND
4.9
ND
2.4
2.6
1.9
13.6
MW-2
4/26/2021
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
1.1
0.78
1.1
1
ND
2.8
7/28/2021
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
ND
NA
NA
NA
2L Class GA Standards
10
15
0.03
700
10000
200
400
N/A
N/A
N/A
400
400
1
600
600
500
2L Class GSA Standards
10
15
0.03
700
10000
200
400
N/A
N/A
N/A
400
400
1
600
600
N/A
2L Class GCL Standards
10000
15000
30
N/A
N/A
N/A
N/A
N/A
N/A
N/A
28500
25000
5000
84500
260000
1 N/A
NOTES:
ND = Not Detected
VPH = Volatile Petroleum Hydrocarbon - Massachusetts Department of
Environmental Protection
EPH = Extractable Petroleum Hydrocarbon - Massachusetts Department of
Environmental Protection
ft. BGS = feet below ground surface
mg/L= milligrams per liter
ug/L = micrograms per liter
Bold data above the 2L Class GA Standards
NA -Not Analyzed
Three Mile
Creek
NThree Mile
Creek
0 25
Feet
Scale Approximate
Sewer -_
Line
City of Kannapolis -
Sewer Right of Way -
Gravel
:- Road
Steep
Wooded
Embankment
Steep
Wooded
Embankment
Hilbish Ford _�
Back Lot
Stormwater
Area of Impact Discharge
Limits of Excavation Pipe f
Area of Impact FIOW Of
Limits of Excavation \S-10 Spilled Oil
S-12
Drain
S-14 S-8 S-6
Tile ♦ S-7
S-17 Roadr S-9
S 11
S-19 S-15
f S-13 MW-1
S-20 MW-2 1 :
S-18/S-25
S-21 S-24
S-22 S-23 :
_ _ _ - Area of Vacuum Gravel
Extraction and Oil Road
_= Removal with
Absorbents and
........ Excavation
I .Sewer
Line
Soil Sample Location
and Collection Depth
Steep
Wooded
Embankment
Spill Location Coordinates
35.459196 N
-80.610201 W
Lighthouse Figure 4 Isgett Distributing
- . ;: • ; Technical,P.C. Post Excavation Used oil Spill
' Environmental Consultants Soil Sample Locations 2600 South Cannon Boulevard
-` Soil and Groundwater Specialists Monitor Well Locations Kannapolis, North Carolina
leAnalyiical
www.pacelabs.com
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
August 04, 2021
Steven Lucas
Lighthouse Technical
PO Box 1379
Huntersville, NC 28078
RE: Project: 21003
Pace Project No.: 92552159
Dear Steven Lucas:
Enclosed are the analytical results for sample(s) received by the laboratory on July 28, 2021. The results relate only to the
samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the
laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report.
The test results provided in this final report were generated by each of the following laboratories within the Pace Network:
• Pace Analytical Services - Charlotte
If you have any questions concerning this report, please feel free to contact me.
Sincerely,
�� 4---
Tyler Forney
tyler.forney@pacelabs.com
(704)875-9092
Project Manager
Enclosures
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.
Page 1 of 11
leAnalyiical
www.pacelabs.com
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
CERTIFICATIONS
Project: 21003
Pace Project No.: 92552159
Pace Analytical Services Charlotte
9800 Kincey Ave. Ste 100, Huntersville, NC 28078
South Carolina Certification #: 99006001
Louisiana/NELAP Certification # LA170028
Florida/NELAP Certification #: E87627
North Carolina Drinking Water Certification #: 37706
Kentucky UST Certification #: 84
North Carolina Field Services Certification #: 5342
Virginia/VELAP Certification #: 460221
North Carolina Wastewater Certification #: 12
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC. Page 2 of 11
leAnalyiical
www.pacelabs.com
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Project: 21003
Pace Project No.: 92552159
Lab ID Sample ID
92552159001 MW-2
PASI-C = Pace Analytical Services - Charlotte
SAMPLE ANALYTE COUNT
Method
SM 6200B
REPORT OF LABORATORY ANALYSIS
Analytes
Analysts Reported
SAS
Laboratory
PASI-C
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.
Page 3 of 11
leAnalyiical
www.pacelabs.com
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
PROJECT NARRATIVE
Project: 21003
Pace Project No.: 92552159
Method: SM 6200B
Description: 6200B MSV
Client: Lighthouse Technical
Date: August 04, 2021
General Information:
1 sample was analyzed for SM 6200B by Pace Analytical Services Charlotte. All samples were received in acceptable condition with
any exceptions noted below or on the chain -of custody and/or the sample condition upon receipt form (SCUR) attached at the end of
this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Internal Standards:
All internal standards were within QC limits with any exceptions noted below.
Surrogates:
All surrogates were within QC limits with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
This data package has been reviewed for quality and completeness and is approved for release.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC. Page 4 of 11
leAnalyiical
www.pacelabs.com
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
ANALYTICAL RESULTS
Project: 21003
Pace Project No.: 92552159
Sample: MW-2
Lab ID: 92552159001 Collected:
07/28/21
14:00
Received: 07/28/21 14:15 Matrix: Water
Parameters
Results Units Report
Limit
DF
Prepared Analyzed
CAS No. Qual
6200B MSV
Analytical Method: SM 6200B
Pace Analytical Services - Charlotte
Benzene
ND ug/L
0.50
1
08/03/21 03:40
71-43-2
Surrogates
1,2-Dichloroethane-d4 (S)
91 %
70-130
1
08/03/21 03:40
17060-07-0
4-Bromofluorobenzene (S)
98 %
70-130
1
08/03/21 03:40
460-00-4
Toluene-d8 (S)
99 %
70-130
1
08/03/21 03:40
2037-26-5
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
Date: 08/04/2021 02:15 PM without the written consent of Pace Analytical Services, LLC. Page 5 of 11
leAnalyiical
www.pacelabs.com
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
QUALITY CONTROL DATA
Project: 21003
Pace Project No.: 92552159
QC Batch: 637465
Analysis Method: SM 6200B
QC Batch Method: SM 6200B
Analysis Description: 6200E MSV
Laboratory: Pace Analytical Services - Charlotte
Associated Lab Samples: 92552159001
METHOD BLANK: 3346546
Matrix: Water
Associated Lab Samples: 92552159001
Blank Reporting
Parameter
Units
Result Limit
Analyzed Qualifiers
Benzene
ug/L
ND 0.50
08/02/21 22:52
1,2-Dichloroethane-d4 (S)
%
88 70-130
08/02/21 22:52
4-Bromofluorobenzene (S)
%
96 70-130
08/02/21 22:52
Toluene-d8 (S)
%
100 70-130
08/02/21 22:52
LABORATORY CONTROL SAMPLE:
3346547
Spike LCS
LCS % Rec
Parameter
Units
Conc. Result
% Rec Limits Qualifiers
Benzene
ug/L
50 46.7
93 60-140
1,2-Dichloroethane-d4 (S)
%
89 70-130
4-Bromofluorobenzene (S)
%
97 70-130
Toluene-d8 (S)
%
97 70-130
MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3346548 3346549
MS MSD
92552771001
Spike Spike MS
MSD MS MSD
% Rec
Parameter
Units
Result
Conc. Conc. Result
Result % Rec % Rec
Limits RPD Qual
Benzene
ug/L
4700
2500 2500 7510
7670 112 119
60-140 2
1,2-Dichloroethane-d4 (S)
%
90 92
70-130
4-Bromofluorobenzene (S)
%
100 98
70-130
Toluene-d8(S)
%
98 100
70-130
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
Date: 08/04/2021 02:15 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 11
leAnalyiical
www.pacelabs.com
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
QUALIFIERS
Project: 21003
Pace Project No.: 92552159
DEFINITIONS
DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot.
ND - Not Detected at or above adjusted reporting limit.
TNTC - Too Numerous To Count
J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit.
MDL -Adjusted Method Detection Limit.
PQL - Practical Quantitation Limit.
RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and
bias for a specific analyte in a specific matrix.
S - Surrogate
1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is
a combined concentration.
Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values.
LCS(D) - Laboratory Control Sample (Duplicate)
MS(D) - Matrix Spike (Duplicate)
DUP - Sample Duplicate
RPD - Relative Percent Difference
NC - Not Calculable.
SG - Silica Gel - Clean -Up
U - Indicates the compound was analyzed for, but not detected.
Acid preservation may not be appropriate for 2 Chloroethylvinyl ether.
A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA
Method 8260.
N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for
each analyte is a combined concentration.
Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes.
TNI -The NELAC Institute.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
Date: 08/04/2021 02:15 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 11
leAnalyiical
www.pacelabs.com
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Project: 21003
Pace Project No.: 92552159
Lab ID Sample ID
92552159001 MW-2
QUALITY CONTROL DATA CROSS REFERENCE TABLE
QC Batch Method
SM 6200B
QC Batch Analytical Method
637465
REPORT OF LABORATORY ANALYSIS
Analytical
Batch
This report shall not be reproduced, except in full,
Date: 08/04/2021 02:15 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 11
Document Name:
Sample Condition Upon Receil
r?CERat'lCr7f - Document No.:
F•CAR-CS-033-Rev.07
Document Revised: October 28, 2020
CUR) Page 1 of 2
Issuing Authority:
Pace Carolinas Qualitv Office
Laboratory receiving samples:
Asheville ❑ Eden❑ Greenwood ❑ Huntersville MV Raleigh❑ Mechanicsville[] Atlanta❑ Kernersville❑
- � Client fame: 92552159
1l�tll�tl�11�1ti�1ti
Custody Seal Present? ❑Yes ErNo Seals Intact? ❑Yes [2No 92SS2159
Date/anitial&0arso"xamining-Gontent
Packing Material: E�Subble wrap 'Bubble Bags ❑None ❑ Other Biological Tissue Frozen?
Thermometer; [:]Yes [:]No RN/A
�4vet ❑slue []None
UIR Gun lD: 92TO64 Type of lea:
Correction Factor:
Cooler Temp: Add/Subtract (°C) .4 1 Temp should be above freezing to 6'C
❑5amples out of temp criteria. Samples on ice, cooling process
Cooler Temp Corrected ('C): ` "� hasbegun
USDA Regulated Soil ( N/A, water sample)
Did samples originate in a quarantine zone within the United States: CA, NY, or SC (check maps)? Did samples originate from a foreign source linternatianaliy,
nYes FINo includim Hawaii and Puerto Rico17 rlYes MNo
Comments/Discrepancy:
Chain of Custody Present?
[Yes
[-]No
[-]N/A
1.
Samples Arrived within Hold Time?
6Yes
❑Na
[_]N/A
2.
Short Hold Tlrne Analysis 102 hr.)?
❑Yes
tANo
❑N/A
3.
Rush Turn Around Time Requested?
❑Yes
No
❑N/A
4.
Sufficient Volume?
MYes
❑No
❑N/A
5.
Correct Containers Used?
Pace Containers Used?
t1y�Y"es
o res
[]No❑N/A
No
❑N/A
6.
Containers Intact?
Yes
❑No
❑N/A
7.
Dissolved analysis: Samples Field Filtered?
[]Yes
❑No
t2 /A
g,
Sample Labels Match COC?
-Includes Date/Time/10/Analysis Matrix:
NFes
ui
❑No
❑N/A
9.
Headspace in VOA Vials (>5-6mm)?
[-]Yes
rffNa
❑N/A
10.
Trip Blank Present?
Trip Blank Custody Seals Present?
❑Yes
[-]Yes
ONO
❑No
`" /A
aA
11.
COMMENTS/SAMPLE DISCREPANCY
CLIENT NOTIFICATION/RESOLUTION
Person contacted:
Project Manager SCURF Review:
Project Manager SRF Review:
Date/Time:
Lot ID of split containers:
Date:
Date:
Field Data Required? ❑Yes ❑No
Page 9 of 11
a
i c7cmjT7c�
Document Name:
Sampie Condition upon Receipt(5CUR)_
Document Revised: October 28, 2020
Page 2 of 2
Document No.:
F-CAR-CS-033•Rev,07
Issuing Authority:
Pace Carolinas Quality Office
"Check mark top half of box if pH and/or dechlorination is
verified and within the acceptance range for preservation
samples.
Exceptions: VOA, Coliform, TOC, Oil and Grease, DRO/8015 (water) DOC, LLHg
**Bottom--half_of_b_ox_is_to list_numb.er_of botties_...._.___.
Project It Wa# : 92552159
PM: ATF Due Date: 08/04/21
CLIENT: 92-Lighthous
U
A
2
Z
Z
4
U
O
ems.
�.Y..
�
Sri
wry_
�*J_
old_
a
e�
<_
—,..�t,r.
�,�
91_
v
v_
tic
i'
?
.�07�
2
i'
c'
s
x
m
m
v
V
x
°
x
z
¢
?
_
4
Z
z
0
m
d
C
a
vci
Q.
v
Q
O
p
01
Q
y�j
A
N
2
V
C
v
Z
Y
m
c
U`
T
=
1^
L
N
>
d
r
0
O
LA
N
n
u
V
u
u
v
u
-m
a
E
z
c
M
0m.a?
Za
ro_cu
N
>EE
M
a
Lon
a
4
Q
4
O
y.
a0
Em
E
E
E
c`i
E
E
E
E
v
y
E
E
}
>
J
>ii
1
E
J
E
m
.�
N
J
E
E
C
E
E
J
a
J
E
ui
o
o
N
�'
vs
a
N
in
ui
=
_
o
N
E
.m
N
a
o
O�
E
O
.N-I
N
7
3J'
e-1
Vi
2
M
N
U
LL
r+
7
ry
2
Vr
N
V7
4
Q
I
Q
H
V
7
0,
ti
Y
,
Y
y.
In
F-
N
q
7
N
7
�
N
a
a
0.
a
a
a
a
Q
rti
t7
11
1.7
M
t1
l7
M
V'
m
l7
G1
@
M
iS
GI
l7
V
t7
4
0
l}
N
N
rM
p
Qi
(CCU
_
m
m
m
m
m
m
m
m
$
a
a
a
¢
a
a
a
>
>
o
>
>
V1
i
m
a
N
I
N
3
4
5
b
7
8
9
10
11
iz
pH Adjustment Log for Preserved Samples
Sample ID
Type of Preservative
pH upon receipt
Date preservation adjusted
Time preservation
adjusted
Amount of Preservative
added
Lat H
Note: whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina DEHNR Certification Office (Le.
Out of hold, incorrect preservative, out of temp, incorrect containers.
Page 10 of 11
C,
N
c
eo
0o
ti
w
u+
A
w
N
ITEM #
C N
�
m
a
m
N
�
C
_
m
Z
to
d$
V
n
M o
r
m O
3
m
w
c
n
mD7n
3 ^
T
z
w m
c '� m M
8
1
m-
10
?c
T
rn
z
N
c
m
s 42�_O cs 9�`{vri
o
O
M
3
p
N OtiA r2 Om r2O
n
n
j
o
-1
o
m
m EL 0
MATRIX CODE (sea valid codes to lea)
z
r
a
Z
M
SAMPLETYPE (G=GRAB (;=COMP)
N
O
m
]
I
v
A
m
m
n
A
la
9
8
m
0
w
�
w
r-
Z
a
rn
z
z
Mn
Z
D
m
Z
n
a
3
3
m'
m
M
o
m
z
°
n
3
n
n
°
M
°
3
N
o
q
n
m
SAMPLE TEMP AT COLLECTION
A
A
m
m m
a o
R OF CONTAINERS
ro
m
N 3
3
(lnpreserved
v
ro
a
o a
N
. a
J
m
H2SO4
U
m
m
Mt
3
C
HNO3
-0m
m
FD
HCI
m
w
m
Na0H
{
h.
>
n
m
(
a
:j
Na25203
_
v
m
Methanol
w
m
Olhar
°
Analyses Test
YIN
v
GRO 8015
3
e
61
m1p
N
�Q
N
a
n
d
V
°
N
T
L
tV
a
O
<
i
Z
#
m
I
TEMP in C
�f
)N
�+
Residual Chlorine (YIN)
>-�
Z
r
°
Received on
r
Ice
b
(YIN)
Fn
O
o
C
m
Custody
c
Sealed
Cooler
o
�J
Y/N
2
_
Samples
Intact
Ll
f YIN}
� n
CD
0n
d
60
G -n
N 0O
Q
N V/
mO
D
17,
0 n
C =
fl
m�
Z1
n n
m X
C
sk)�
am
V N
N rF
30
�o
ro n
n C
B(D
ro �
a
IN
n
n
n
m
Page 11 of 11
Beverly, Trudy
From: Beverly, Trudy
Sent: Wednesday, August 25, 2021 6:41 AM
To: steve@lighthousetechcorp.com
Subject: RE: [External] Additional data for MW-2, Isgett Distributers Used Oil Spill, Kannapolis,
NC
Received.
Trudy
Trudy Beverly, L.G.
D-�IE Hydrogeologist, Division of Waste Management
North Carolina Department of Environmental Quality
IFepnrlren[ol Gma'nn mental4w
UST Section, Mooresville Regional Office
704.235.2182 (Office)
Trudy. B everlyAncdenn gov
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.
Office Mailing Address:
610 East Center Avenue, Suite 301
Mooresville, NC 28115
Branch's Underground Storage Tanks Website Address: https://deg.nc.gov/about/divisions/waste-management/ust
Branch's Above Ground Storage Tanks Website Address: hit2s://deq.nc.gov/about/divisions/waste-management/ust/ast-program
INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES:
httns://dea.nc. gov/about/divisions/waste-management/waste-management-rules-data/waste-management-gis-mans
File Review Procedures:
hops://deq.ne. gov/about/divisions/waste-management/ust/file-review-procedures#mooresville-regional-office
ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche):
fts://deq.nc.gov/about/divisions/waste-manaizement/laserfiche
Document Submittal & UST File Names for Laserfiche Policies:
htti)s:Hfiles.ne.izov/nedeafWaste%2OManasement/DWM/UST[WhatsNew/Final-Electronic-Document-Submittal-Policv.l)df
https:Hfiles.nc.gov/ncdeq/Waste%20Management/D WM/UST/Corrective%2OAction/UST%2Ofilc%20names%20for%2OLaserfiche.docx
From: Steve@lighthousetechcorp.com [mailto:steve@lighthousetechcorp.com]
Sent: Tuesday, August 24, 2021 3:47 PM
To: Beverly, Trudy <trudy.beverly@ncdenr.gov>
Subject: [External] Additional data for MW-2, Isgett Distributers Used Oil Spill, Kannapolis, NC
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to
Report Spam.
Hi Trudy
Additional sampling data for MW-2.
Thanks
Steve
Steven B. Lucas, L.G.
Environmental Geologist
Lighthouse Technical, P.C.
PO Box 1379
Huntersville, North Carolina 28070
704-237-4209 Office
704-439-7439 Cell
www.lighthousetechcorp.com