Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1101_Buncombe_MSWLF_April21GW_FID1596442_20210812
DEN R USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Bunnell-Lammons Engineering Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Andrew W. Alexander E-mail: andy.alexander(cDblecorp.com Phone: 864-288-1265 NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Id Buncombe County Landfill 2726 Riverside Drive, Woodfin, NC, 28804 1101-MSWLF .1600 April 28-29, 2021 1979 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑ Detection Monitoring ❑X Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑ Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data El water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? No. No groundwater or surface water standards were exceeded. X Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑ Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Andrew W. Alexander, PG RSM Consulting Hydrogeologist 864-288-1265 Facility Representative Name (Print) Title (Area Code) Telephone Number �� w a• �E,o•,....=a•d,a ®e,•o.owm, 08-03-2021 Signature Date 6004 Ponders Court, Greenville, SC, 29615 Facility Representative Address C-284 & C-1538 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 Affix NC Licensed/ Professional Geologist Seal .% �ZN CAFJ04 NSF''y% • ,�. t 5 Z iLOG X y W A. C'I►o ����►11I1 1 1�N%t REPORT OF WATER QUALITY SAMPLING AND ANALYSIS 1st SEMI—ANNUAL EVENT 2021 OLD BUNCOMBE COUNTY LANDFILL WOODFIN, NORTH CAROLINA DWM Permit Number 1101-MSWLF-1979 DWR UIC Permit No. WI0100353 Prepared For: Buncombe County, North Carolina BLE Project Number J21-14175-05 August 3, 2021 BLE North Carolina Business Licenses C-284 & C-1538 IM 13UNNELL M LAMMONS ENGINEERING 6004 Ponders Court I Greenville, 5C 29615 864-288.1265 A 864,286.4330 0 info@hle[orp.com BLECORMOM � LAMM(INS ENGINEERING August 3, 2021 Buncombe County Solid Waste Department 81 Panther Branch Road Alexander, North Carolina 28701 Attention: Ms. Kristy Smith Subject: Report of Water Quality Sampling and Analysis 1" Semi -Annual Event 2021 Old Buncombe County Landfill Woodfin, North Carolina DWM Permit Number 1101-MSWLF-1979 DWR UIC Permit No. W10100353 BLE Project Number J21-14175-05 Dear Ms. Smith: Pursuant to Buncombe County authorization of Bunnell-Lammons Engineering, Inc. (BLE) Proposal Number J21-14175-05, dated January 15, 2021, BLE has prepared this report of the groundwater and surface water sampling and laboratory analysis for the 1 s1 semi-annual sampling event of 2021 at the Old Buncombe County Landfill. Consistent with the North Carolina Division of Waste Management (DWM) — Solid Waste Section (SWS) and the North Carolina Division of Water Resources (DWR) approved monitoring program, sampling and analysis will be conducted twice in 2021. This report contains the information required by both the DWM and DWR to document the sampling and analysis activities for the lst semi-annual sampling event of 2021 in the State's permanent project record. Sincerely, BUNNELL LAMMONs ENGINEERING INC. Ril . Blais, .LT. Staff Hydrogeologist cc: Ms. Jaclynne Drummond — DWM-ARO Mr. Brett Laverty, P.G. — DWR-ARO Mr. Michael Rogers, P.G. — DWR-CO Atel Andrew W. Ale der, P.G., RSM Senior Hydrogeologist Registered, NC #1475 Ilblegvlsvrllsolidwasteprojectslbuncombe county closed lf, ncU4175-05 spring 2021 semi reportlold bclf 1101-mswlf--1979 202121st semi-annual 14175-05.docx 6004 Ponders Court, Greenville, SC 29615 ( H!54.28B.1265 a B64.288.4430 045info@hleMrp com 6LECORP.COM 1s 1m 1i Old Buncombe County Landfill — Woodfin, North Carolina August 3, 2021 Report of Groundwater Sampling and Analysis — Is'Semi-Annual Event 2021 BLE Project No. J21-14175-05 TABLE OF CONTENTS 1.0 PROJECT INFORMATION........................................................................................................1 2.0 FIELD ACTIVITIES, SAMPLING, AND ANALYSIS.............................................................1 3.0 GROUNDWATER FLOW........................................................................................................... 2 4.0 RESULTS....................................................................................................................................... 2 4.1 Groundwater.................................................................................................................................... 2 4.2 Surface Water.................................................................................................................................. 3 4.3 Geochemical Parameters for Monitored Natural Attenuation......................................................... 4 5.0 CONCLUSIONS AND RECOMMENDATIONS....................................................................... 4 6.0 QUALIFICATIONS OF REPORT.............................................................................................. 4 7.0 CLOSING.......................................................................................................................................4 Tables Table 1 SWS Approved Groundwater Sampling and Analysis Matrix Table 2 SWS Approved Surface Water Sampling and Analysis Matrix Table 3 Well Construction and Monitoring Well Data Table 4 Groundwater VOCs Table 5 Groundwater Field Parameters and Total Metals Table 6 Surface Water VOCs Table 7 Surface Water Field Parameters and Total Metals Table 8 Groundwater Transects for Remedial Table 9 Groundwater Geochemical Parameters for MNA Figures Figure 1 Site Location Map Figure 2 Groundwater Elevation Contour Map — April 27, 2021 Appendices Appendix A Field Sampling Logs — Pace Analytical Services, LLC. Appendix B Laboratory Analytical Data — Pace Analytical Services, LLC. 1 of 1 1s 1m 1i Old Buncombe County Landfill — Woodfin, North Carolina August 3, 2021 Report of Groundwater Sampling and Analysis — Is'Semi-Annual Event 2021 BLE Project No. J21-14175-05 1.0 PROJECT INFORMATION Buncombe County provides post -closure care for the Pre -Subtitle D MSWLF (unlined) located at 2726 Riverside Drive, Woodfin, North Carolina (Figure 1). The county operated the facility as a municipal solid waste (MSW), industrial solid waste (ISW), and construction and demolition (C&D) landfill. The landfill is separated into four (4) separate waste areas labeled A through D. Waste areas A, B, and C stopped receiving waste before October 9, 1991 and waste area D stopped receiving waste on September 27, 1997. Groundwater and surface water monitoring is performed at the site in accordance with a DWM approved Corrective Action Plan (CAP) dated September 3, 2014 [DIN 21838 (SCS Engineers File No 09204072.06)] and a DWM approved Request for Reduction of MNA Parameters dated November 30, 2016 [DIN 27144 (SCS Engineers File No 09204072.14)]. The facility requires semi-annual groundwater and surface water monitoring and reporting in accordance with the CAP, et seq. Prior to the second semi-annual sampling event of 2020, BLE submitted (on behalf of Buncombe County) the Report of 1,4-Dioxane Sampling and Analysis November 2018 to April 2020 dated September 1, 2020 [FID 145059] which was approved by the DWM and updated the groundwater and surface water matrix. As part of the correction action at the facility, Buncombe County applied for, and was granted a permit for subsurface injection of materials for enhanced bioremediation of VOCs in groundwater. The Underground Injection Control (UIC) Permit (No W10100353) was transmitted by the DWR on September 11, 2015. The permit issue date was September 15, 2015. The permit was renewed on September 21, 2020 and expires on August 31, 2025 (effective dates). The UIC permit requires groundwater monitoring and reporting. We understand that this semi-annual monitoring report prepared as part of the DWM approved sampling and analysis matrix is sufficient to meet the monitoring requirements of the UIC permit. The active groundwater monitoring network for the Closed Buncombe County Landfill consists of one (1) upgradient (background) well and twenty-three (23) downgradient (compliance, performance, and sentinel) wells. There are a total of fourteen (14) additional wells that are considering inactive for sampling purposes and are used for collecting water levels only (Table 1). Five (5) active surface water monitoring locations have been established for the facility to monitor surface water quality. The existing surface water locations consist of one (1) upstream (background) location and four (4) downstream (compliance) locations. Five (5) inactive surface water monitoring locations have been established but are not sampled (Table 2). 2.0 FIELD ACTIVITIES, SAMPLING, AND ANALYSIS Groundwater and surface water samples were collected for the I' semi-annual sampling event by personnel from Pace Analytical Services, LLC. (Pace) of Asheville, North Carolina between April 28-29, 2021. Groundwater samples were collected from twenty-three (23) of the twenty-four (24) active groundwater monitoring well locations located on the site (Table 1). One well (MW-24-45) was dry, and therefore, was not sampled. Additionally, the five (5) surface water locations were sampled during the event (Table 2). The groundwater and surface water samples were delivered to Pace Analytical Services, LLC. (Pace) of Columbia, South Carolina and analyzed in the laboratory per the approved monitoring plan. The field 1 of 2 1s 1M 1i Old Buncombe County Landfill — Woodfin, North Carolina August 3, 2021 Report of Groundwater Sampling and Analysis — Is'Semi-Annual Event 2021 BLE Project No. J21-14175-05 parameters of dissolved oxygen, pH, redox potential, specific conductance, turbidity, and temperature were measured in the field by Pace. A copy of the Pace field sampling logs is included in Appendix A. A copy of the laboratory analytical data is included in Appendix B. 3.0 GROUNDWATER FLOW The water level data collected during the groundwater sampling event on April 28-29, 2021 is presented in Table 3. A groundwater elevation contour map is presented as Figure 2 which includes generalized groundwater flow directions. 4.0 RESULTS 4.1 Groundwater The results of the groundwater field and laboratory analyses are summarized on Tables 4 and 5 and the laboratory analytical data is included in Appendix B. VOC detections during the current sampling event included: • Acetone (3 wells); • Benzene (10 wells); • Carbon Disulfide (3 wells); • Chlorobenzene (13 wells); • Chloroethane (11 wells); • 1,2-Dichlorobenzene (1,2 DCB) (6 wells); • 1,4-Dichlorobenzene (1,4 DCB) (17 wells); • 1, 1 -Dichlorethane (1,1 DCA) (12 wells); • 1,2-Dichlorethane (1,2 DCA) (2 wells); • cis-1,2-Dichloroethene (cis-DCE) (14 wells); • trans-1,2-Dichloroethene (trans-DCE) (1 well); • Ethylbenzene (1 well); • 2-Butanone (1 well); • 4-Methyl-2-Pentanone (1 well); • Tetrachloroethene (7 wells); • Toluene (2 wells); • Trichloroethene (3 wells); • Vinyl chloride (11 wells); • Total Xylenes (5 wells); and • 1,4-Dioxane (14 wells). Total metal detections during the current sampling event included: • total antimony (2 wells); • total arsenic (1 well); • total barium (23 wells); • total beryllium (2 wells); 2 of 3 1s 1M 1i Old Buncombe County Landfill — Woodfin, North Carolina August 3, 2021 Report of Groundwater Sampling and Analysis — Is'Semi-Annual Event 2021 BLE Project No. J21-14175-05 • total cadmium (4 wells); • total chromium (3 wells); • total cobalt (9 wells); • total copper (6 wells); • total lead (6 wells); • total nickel (17 wells); • total selenium (3 wells); and • total zinc (15 wells). Please refer to Tables 4 and 5 for a summary of which groundwater constituents exceed North Carolina Groundwater Quality Standards (NC2L) maximum contaminant levels' (MCLs). It is noted that the detections of PCE in the groundwater are B-flagged by the laboratory, indicating a laboratory error. Field parameters measured in the groundwater included dissolved oxygen, pH, redox potential, specific conductance, turbidity, and temperature. 4.2 Surface Water The results of the surface water field and laboratory analyses are summarized on Tables 6 and 7 and the laboratory analytical data is included in Appendix B. VOC detections during the current sampling event included: • 1,4-Dioxane (3 locations). Total metal detections during the current sampling event included: • total barium (all locations); • total cobalt (2 locations); • total copper (1 location); • total lead (1 location); • total nickel (2 locations); • total selenium (1 location); and • total zinc (3 locations). Field parameters measured in the surface water included dissolved oxygen, pH, redox potential, specific conductance, turbidity, and temperature. Please refer to Table 6 and 7 for a summary of which surface water constituents and field parameters exceeded their established North Carolina Surface Water Quality Standards (NC2B)2 standard limits. ' North Carolina Department of Environmental Quality, Classifications of Water Quality Standards, Section 15A NCAC 2L.202, July 24, 2020. 2 North Carolina Department of Environmental Quality, Surface Waters and Wetlands Standards, Section 15A NCAC 02B workbook dated June 10, 2019. 3 of 4 1s 1m 1i Old Buncombe County Landfill — Woodfin, North Carolina August 3, 2021 Report of Groundwater Sampling and Analysis — Is'Semi-Annual Event 2021 BLE Project No. J21-14175-05 4.3 Geochemical Parameters for Monitored Natural Attenuation Buncombe County selected Monitored Natural Attenuation (MNA), Institutional Controls (restrictive cover; a.k.a. landfill cap), and In Situ Enhanced Bioremediation and Bioaugmentation as the groundwater remedies for the facility. The selected remedies are in progress. A series of transects along groundwater flow paths were identified in the CAP, et. Seq, which includes groundwater monitoring wells selected for remedial monitoring. A summary table which identifies each transect (1 through 5) and associated monitoring wells is included as Table 8. Sampling for specific geochemical parameters to evaluate remedial performance were performed during the I't semi-annual event of 2021. Those results are summarized on Table 9 and the laboratory analytical data is included in Appendix B. A corrective action evaluation report (CAER) will be submitted by BLE on behalf of Buncombe County later in 2021. 5.0 CONCLUSIONS AND RECOMMENDATIONS Semi-annual assessment monitoring was performed during the I' semi-annual event of 2021 in general accordance with the approved CAP and monitoring plan. Detected constituents which exceed their respective groundwater and surface water standards are identified on the summary tables. We conclude that the PCE detections in the groundwater during this event are a result of laboratory error. We recommend that semi-annual sampling continue in accordance the approved CAP and monitoring plan. 6.0 QUALIFICATIONS OF REPORT The activities and evaluative approaches used in this assessment are consistent with those normally employed in hydrogeological and environmental assessments of this type. Our evaluation of site conditions has been based on our understanding of the site and project information and the data provided to BLE. This report has been prepared on behalf of and exclusively for the use of Buncombe County, North Carolina. This report and the findings contained herein shall not, in whole or in part, be used or relied upon by any other party (excluding the DWM and DWR) without BLE's prior written consent. 7.0 CLOSING We appreciate the opportunity to be of service to Buncombe County, North Carolina. Please contact us at (864) 288-1265 if you have any questions or comments. 4 of 4 Tables Table 1 SWS Approved Groundwater Sampling and Analysis Matrix Closed Buncombe County Landfill Woodfin, North Carolina Permit No. 1101-MSWLF-1979 BLE Project Number J21-14175-05 Standard Semi -Annual Laboratory Parameters Standard Semi -Annual Field Parameters Semi -Annual Geochemical Parameters for MNA Monitoring Well Well Status Transect Number Appendix I VOCs (EPA 8260B) 1,4-dioxane (EPA 8260 SIM) Appendix II Full List Appendix I (Various Methods) Metals WL Turb Temp pH ORP DO SC Alkalinity DH VFA TOC BOD COD Chloride CO2 FeZ NO3 MEE SO4 Sulfide DPL-1 Active 5 Y Y O Y - Y Y Y Y Y Y Y Y Y DPL-2 Injection 4 MW-A Inactive - MW-B Active 2 Y Y Y Y Y Y Y Y Y MW-2 Active - Y O Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y MW-3 Active 3 Y Y - Y Y Y Y Y Y Y Y MW-4 Active 4 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y MW-4A Active 1 Y Y - Y Y Y Y Y Y Y Y MW-5 Active 5 Y Y O Y Y Y Y Y Y Y Y MW-6 Active 5 Y Y O Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y MW-6-192 Active 5 Y Y - Y Y Y Y Y Y Y Y MW-7 Active - Y Y Y Y Y Y Y Y Y MW-8 Inactive - Y MW-9 Abandoned - MW-10 Abandoned MW-12-10 Inactive - Y MW-12-25 Active 1 Y Y Y Y Y Y Y Y Y MW-13-10 Inactive - Y MW-13-35 Active 1 Y Y Y Y Y Y Y Y Y MW-13-132 Active 1 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y MW-14 Inactive - Y MW-15 Active Y Y Y Y Y Y Y Y Y MW-16 Abandoned MW-17 Abandoned MW-17-60 Active 2 Y Y Y Y Y Y Y Y Y Y MW-17-137 Active 2 Y Y Y Y Y Y Y Y Y Y MW-17-310 Active - Y Y Y Y Y Y Y Y Y MW-18-3 Inactive - Y MW-18-78 Active 5 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y MW-19-4 Inactive - Y MW-19-75 Active 4 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y MW-19-110 Active 4 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y MW-20-3 Inactive - Y MW-20-32 Inactive Y MW-21-4 Inactive - Y MW-21-21 Active 3 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y MW-21-94 Active 3 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y MW-22-78 Inactive - Y MW-22-143 Inactive Y MW-23-119 Inactive Y MW-23-186 Inactive - Y MW-24-45 Active 1 Y Y Y Y Y Y Y Y Y Y MW-24-160 Active 1 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Notes: Typical Events: April (Spring) and October (Fall) BOD = Biologic Oxygen Demand 0 = October (Fall) Only COD = Chemical Oxygen Demand VOCs = Volatile Organic Compounds 40 CFR Part 258 Appendix I - Constituents for Detection Monitoring (Organics and Inorganics) SWS Approved Matrix on September 1, 2020 40 CFR Part 258 Appendix II - Constituents for Assessment Monitoring (Full List) WL = Water Level ORP = Oxidation Reduction Potential DO = Dissolved Oxygen SC = Specific Conductance DH = Dissolved Hydrogen VFA = Volatile Fatty Acids TOC = Total Organic Carbon Fee = Iron II NO3 = Nitrate MEE = Methane/Ethene/Ethane SO4 = Sulfate CO2 = Carbon Dioxide GW Approved Matrix Tl of Approved 2020-09-01 Closed BCLF GW and SW Matrix for Spring 2021.xlsx Prepared By: AWA Checked By: TJD Table 2 SWS Approved Surface Water Sampling and Analysis Matrix Closed Buncombe County Landfill Woodfin, North Carolina Permit No. 1101-MSWLF-1979 BLE Project Number J21-14175-05 Standard Semi -Annual Laborator Parameters Standard Semi -Annual Field Parameters Surface Water Location Location Status Appendix I VOCs (EPA 8260B) 1,4-dioxane (EPA 8260 SIM) Appendix I Metals Turb Temp pH ORP DO SC SW-1 Active Y - Y Y Y Y Y Y Y SW-2 Active Y - Y Y Y Y Y Y Y SW-2A Active Y Y Y Y Y Y Y Y Y SW-3 Active Y Y Y Y Y Y Y Y Y SW-4 Active Y Y Y Y Y Y Y Y Y SW-5 Inactive - - - - - - - - - SW-6 Inactive - - - - - - - - - SW-7 Inactive - - - - - - - - - SW-8 Inactive - - - - - - - - - SW-9 1 Inactive - - - - - - - - - Notes: Typical Events: April (Spring) and October (Fall) VOCs = Volatile Organic Compounds Y=Yes 40 CFR Part 258 Appendix I - Constituents for Detection Monitoring (Organics and Inorganics) SWS Approved Matrix on September 1, 2020 SW Approved Matrix T2 of Approved 2020-09-01 Closed BCLF GW and SW Matrix for Spring 2021.xlsx ORP = Oxidation Reduction Potential DO = Dissolved Oxygen SC = Specific Conductance Prepared By: AWA Checked By: TJD Table 3 Well Construction and Monitoring Well Data Old Buncombe County Landfill Woodfin, North Carolina Permit No. 1101-MSWLF-1979 BLE Project Number J21-14175-05 Monitoring Point Northing' Easting' TOC Elevation (ft)' GS Elevation (ft)' Depth to GW (ft) April 27, 2021 Groundwater Elevation (ft) Well Depth (ft)' Screen Depth (below GS)' Geology Monitored' Well Status/Purpose DPL-1 714,361.2 928,456.1 2040.73 2038.23 65.00 1975.73 65 55 - 65 Bedrock Compliance DPL-2 714,508.1 928,812.6 2112.15 2109.65 A A 97 87 - 97 Bedrock Injection MW-A 714,654.47 931,068.90 2063.37 2061.90 0.00 2063.37 33 23 - 33 Bedrock DNA MW-B 713,635.93 930,421.08 1960.86 1960.30 3.76 1957.10 15 5 - 15 Bedrock Compliance MW-2 715,052.9 930,063.8 2205.33 2203.40 107.55 2097.78 175 145 - 175 Bedrock Background MW-3 713,790.10 929,814.44 1991.15 1989.90 62.85 1928.30 90 60 - 90 Bedrock Compliance MW-4 714,177.83 928,875.09 2014.27 2013.60 72.01 1942.26 75 55 - 75 Bedrock Performance MW-4A 713,351.70 931,195.02 2083.10 2082.50 66.24 2016.86 77 67 - 77 Bedrock Compliance MW-5 714,620.07 928,174.58 2019.73 2019.00 47.81 1971.92 80 70 - 80 Bedrock Compliance MW-6 715,103.13 928,152.69 2002.08 2000.30 0.00 2002.08 40 30 - 40 Bedrock Performance MW-6-192 715,146.34 928,113.86 2009.02 2006.73 25.14 1983.88 192 182 - 192 Bedrock Compliance MW-7 715,604.13 930,534.81 2108.86 2107.70 21.31 2087.55 29 14 - 29 Saprolite Compliance MW-8 716,107.98 930,308.94 2079.02 2077.20 24.04 2054.98 38 23 - 38 Saprolite DNA MW-9 716,024.04 928,619.48 2061.59 2060.00 A A 29 14 - 29 Saprolite DNA MW-10 716,086.5 929,060.5 2049.67 2047.40 A A 19 9 - 19 Saprolite DNA MW-12-10 DNA DNA 2028.03 2024.94 Dry Dry 8 4 - 8 Saprolite DNA MW-12-25 713,258.9 931,353.0 2029.98 2026.36 7.76 2022.22 26 16 - 26 Bedrock Compliance MW-13-10 713,000.2 931,279.7 2012.26 2009.85 3.53 2008.73 10 4 - 10 Saprolite DNA MW-13-35 713,023.1 931,236.9 2017.68 2014.13 5.65 2012.03 35 25 - 35 Bedrock Compliance MW-13-132 712,997.8 931,274.0 2012.89 2009.58 22.15 1990.74 132 122 - 132 Bedrock Performance MW-14 716,348.1 930,124.0 2053.46 2049.61 6.89 2046.57 55 40 - 55 Bedrock DNA MW-15 716,995.2 929,509.6 2028.08 2024.08 4.57 2023.51 72 62 - 72 Bedrock Compliance MW-16 716,170.0 929,107.2 2048.13 2045.13 A A 94 84 - 94 Bedrock DNA MW-17 DNA DNA DNA DNA A A DNA DNA -DNA DNA DNA MW-17-60 713,339.0 930,205.8 1922.97 1920.35 22.30 1900.67 60 50 - 60 Bedrock Compliance MW-17-137 713,329.8 930,199.1 1921.73 1919.24 20.87 1900.86 137 127 - 137 Bedrock Compliance MW-17-310 713,302.4 930,207.9 DNA 1918.00 0.00 DNA 310 300 - 310 Bedrock Compliance MW-18-3 714,130.9 927,843.0 1895.62 1892.62 Dry Dry 3 1 - 3 Flood Plain DNA MW-18-78 714,131.1 927,848.7 1894.62 1891.62 6.60 1888.02 78 1 68 - 78 Bedrock Sentinel MW-19-4 713,953.9 928,939.4 1902.27 1898.97 Dry Dry 4 2 - 4 Flood Plain DNA MW-19-75 713,948.7 928,950.0 1900.72 1898.02 9.45 1891.27 75 65 - 75 Bedrock Compliance MW-19-110 713,951.7 928,942.4 1901.43 1898.53 10.14 1891.29 110 100 - 110 Bedrock Sentinel MW-20-3 713,865.0 929,310.2 1898.90 1895.90 Dry Dry 3 2 - 3 Flood Plain DNA MW-20-32 713,879.0 929,332.7 1899.57 1896.67 6.23 1893.34 32 22 - 32 Bedrock DNA MW-21-4 713,810.5 929,567.5 1900.33 1896.73 6.30 1894.03 4 1 2 - 4 Flood Plain DNA MW-21-21 713,826.6 929,581.7 1900.49 1897.49 5.06 1895.43 21 11 - 21 Bedrock Performance MW-21-94 713,829.5 929,577.5 1901.06 1897.76 7.69 1893.37 94 84 - 94 Bedrock Sentinel MW-22-78 716,370.39 930,380.26 2068.13 2065.92 23.77 2044.36 79 69 - 79 Bedrock DNA MW-22-143 716,306.96 930,320.49 2068.34 2066.17 43.33 2025.01 148 138 - 148 Bedrock DNA MW-23-119 716,014.05 930,476.24 2076.61 2074.37 41.70 2034.91 120 110 - 120 Bedrock DNA MW-23-186 716,004.53 930,480.42 2076.43 2074.29 51.29 2025.14 186 176 - 186 Bedrock DNA MW-24-45 1711,372.031930,963.221 1932.07 1 1929.82 1 Dry I Dry 45 35 - 45 Bedrock I Compliance_] MW-24-160 1711,435.811931,042.731 1933.24 1 1930.93 1 94.90 1 1838.34 1 160 1 150 - 160 1 Bedrock I Sentinel -Data from Table 1, Well Construction Summary, from Old Buncombe County Landfill Corrective Action Plan, by SCS Engineers, Dated September 3, 2014. 2 - Water levels were collected for these wells but no accurate survey data is available. TOC - Top of Casing GS - Ground Surface DNA - Data Not Available A - Abandoned 14175-05 GW Tables Prepared By: RLB Table 3 April 2021 Checked By: IAI Table 4 Groundwater VOCs Old Buncombe County Landfill Woodfin, North Carolina Permit No. 1101-MSWLF-1979 BLE Project Number J21-14175-05 Sampled by Pace Analytical Services, LLC. April 28-29, 2021 TEST UNITS MRL MDL MCL MW-B MW-2 AM-3 MW4 MW4A MW-5 NM-6 MW-6-192 NM-7 MW-12-25 NM-13-35 MW-13-132 NM-15 MW-17-60 MW-17-137 MW-17-310 MW-18-78 MW-19-75 MW-19-110 MW-21-21 MW-21-94 MW-2445 MW-24-160 DPL-1 Acetone µg/1 20 5.0 6,000 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 <5.0 12 J <5.0 <5.0 <5.0 <5.0 5.2 J <5.0 <5.0 <5.0 Dry <5.0 11 J Acrylonitrile 119/1 20 0.80 NE <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 <0.80 Dry <0.80 <0.80 Benzene µg/1 1.0 0.40 1.0 <0.40 <0.40 1.6 0.86 J 5.6 0.86 J 1.3 <0.40 2.4 <0.40 1.1 1 <0.40 <0.40 <0.40 <0.40 0.53 J <0.40 <0.40 2.8 <0.40 Dry <0.40 <0.40 Bromochloromethane 119/1 1.0 0.40 NE <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Bromodichlorometbane 99/1 1.0 0.40 0.6 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Bromoform 119/1 1.0 0.40 4.0 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 1 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Carbon Disulfide 119/1 1.0 0.40 700 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 4.2 <0.40 <0.40 <0.40 <0.40 2.7 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 0.53 J <0.40 Dry <0.40 <0.40 Bromometbane (Methylbromide) 99/1 2.0 0.40 10.0 (i) <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Carbon tetrachloride 119/1 1.0 0.40 0.3 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Chlorobenzene (mono) 119/1 1.0 0.40 50 <0.40 <0.40 4.4 6 28 8.7 7.5 0.96 J 13 <0.40 5 <0.40 <0.40 <0.40 <0.40 <0.40 4 4.2 0.78 J 32 1.8 Dry <0.40 <0.40 Chloroethane 99/1 2.0 0.40 3,000 0.61 J <0.40 3.2 2 <0.40 1.0 J 3.5 0.65 J 3.4 <0.40 <0.40 <0.40 <0.40 <0.40 0.43 J <0.40 0.70 J <0.40 0.87 J <0.40 2.3 Dry <0.40 <0.40 Chloroform 119/1 1.0 0.40 70 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Chloromethane (Methylchloride) µg/1 1.0 0.50 3.0 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 Dry <0.50 <0.50 Dibromochloromethane 99/1 1.0 0.40 0.4 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 1,2-Dibromo-3-chlompropane; DBCP 119/1 1.0 0.40 0.04 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 1,2-Dibmmoethane; Ethylene dibromide 119/1 1.0 0.40 0.02 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Dibromomethane µg/1 1.0 0.40 70.0 (i) <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 1,2-Dichlorobenzene 119/1 1.0 0.40 20.0 <0.40 <0.40 0.83 J 0.73 J 4.4 <0.40 <0.40 <0.40 <0.40 <0.40 3.1 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 4 0.44 J Dry <0.40 <0.40 1,4-Dichlorobenzene µg/1 1.0 0.40 6.0 0.75 J <0.40 7.2 9.5 25 4.8 2.6 0.43 J 5.8 <0.40 16 0.58 J <0.40 0.53 J 0.68 J <0.40 3.1 3.2 0.76 J 14 2.8 Dry <0.40 <0.40 trans-1,4-Dichloro-2-butene µg/1 2.0 0.50 NE <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 Dry <0.50 <0.50 1,1-Dichloroethane 119/1 1.0 0.40 6.0 <0.40 <0.40 1.3 7.2 <0.40 0.51 J 1.8 0.69 J 2.1 <0.40 <0.40 <0.40 <0.40 1.1 0.78 J <0.40 0.98 J 0.47 J <0.40 2.8 1.2 Dry <0.40 <0.40 1,2-Dichloroethane 119/1 1.0 0.40 0.4 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 0.43 J 0.42 J Dry <0.40 <0.40 IJ-Dichlomethene(-ethylene) 99/1 1.0 0.40 350 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 cis-1,2-Dichloroethene (-ethylene) 119/1 1.0 0.40 70 4.7 <0.40 0.65 J 16 <0.40 <0.40 1.4 <0.40 20 0.57 J 2.7 2.6 <0.40 2.5 0.61 J <0.40 0.95 J <0.40 0.93 J 5.8 2.9 Dry <0.40 <0.40 trans-1,2-Dichloroethene (-ylene) µg/1 1.0 0.40 100 <0.40 <0.40 <0.40 <0.40 0.44 J <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 1,2-Dichloropropane 99/1 1.0 0.40 0.6 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 cis-1,3-Dichloropropene (-propylene) 119/1 1.0 0.40 0.4 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 trans-1,3-Dichlompropene (-propylene) µg/1 1.0 0.40 0.4 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Ethylbenzene 99/1 1.0 0.40 600 <0.40 <0.40 <0.40 <0.40 6.8 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 2-Hex anone µg/1 10.0 2.0 40.0 (1) <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 Dry <2.0 <2.0 Iodomethane 119/1 5.0 0.40 NE <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Dichlorometbane (Methylene chloride) 99/1 1.0 0.40 5.0 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 2-Butanone (Methyl ethyl ketone) µg/1 10.0 2.0 4,000 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 3.4 J <2.0 <2.0 <2.0 <2.0 <2.0 Dry <2.0 <2.0 4-Methyl-2-Pentanone µg/1 10.0 2.0 NE <2.0 <2.0 <2.0 <2.0 4.9 J <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 <2.0 Dry <2.0 <2.0 Styrene µg/1 1.0 0.41 70.0 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 <0.41 Dry <0.41 <0.41 1,1,1,2-Tetrachloroethane 119/1 1.0 0.40 1.0 (i) <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 1,1,2,2-Tetrachloroethane 119/1 1.0 0.40 0.2 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Tetrachloroethene (-ethylene) 99/1 1.0 0.40 0.7 0.68 BJ <0.40 <0.40 1.2 B <0.40 <0.40 0.87 BJ <0.40 <0.40 0.63 BJ 0.66 BJ 0.53 BJ <0.40 0.54 BJ 0.51 BJ <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Toluene 119/1 1.0 0.40 600 <0.40 <0.40 <0.40 <0.40 2.7 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 0.66 J <0.40 Dry <0.40 <0.40 1,1,1-Trichloroethane 119/1 1.0 0.40 200 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 1,1,2-Trlchloroethane 99/1 1.0 0.40 0.6 (i) <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Trichloroethene (-ethylene) 119/1 1.0 0.40 3.0 <0.40 <0.40 <0.40 0.82 J <0.40 <0.40 <0.40 <0.40 0.60 J <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 0.51 J <0.40 Dry <0.40 <0.40 Trichlomfluoromethane 119/1 1.0 0.40 2,000 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 1,2,3-Trichloropropane 99/1 1.0 0.40 0.005 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 <0.40 Dry <0.40 <0.40 Vinyl acetate µg/1 5.0 1.2 88.0(1) <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <12 <1.2 <1.2 <1.2 <1.2 <1.2 <12 <1.2 <12 <1.2 <1.2 <1.2 Dry <1.2 <1.2 Vinyl chloride 119/1 1.0 0.40 0.03 2.3 <0.40 0.72 J 3 1 <0.40 <0.40 <0.40 <0.40 <0.40 0.61 J 0.91 J <0.40 1.2 0.74 J <0.40 0.83 J <0.40 <0.40 2.2 1.2 Dry <0.40 <0.40 Total Xylenes 119/1 1.0 0.40 500 <0.40 <0.40 0.89 J <0.40 12 <0.40 <0.40 <0.40 0.54 J <0.40 <0.40 <0.40 <0.40 <0.40 0.46 J <0.40 <0.40 <0.40 <0.40 0.60 J <0.40 Dry <0.40 <0.40 1,4-Dioxane 3.0 1.0 3.0 22 NT 95 24 31 73 33 5.6 NT NT NT NT NT 26 35 NT 53 87 35 30 46 NT <1.0 JApp. II Volatile Organic Compounds (VOC's) Various Various Various Variousl NT ND NT NT NT ND ND NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Notes: 1. MCL = Maximum Contaminant Level, as established in the NCDENR, Classifications of Water Quality Standards Applicable to Groundwaters of North Carolina, Section 15A NCAC 2L .0202. Updated July 24, 2020 2. (i) = Interim Maximum Allowable Concentrations (IMACs). Updated April 6, 2018 3. Shaded cells indicate exceedances of IMACs 4. Shaded cells indicated exceedances of MCLs 6. MRL = Method Reporting Limit 7. MDL -Minimum Detection Limit 8. NT = Not Tested 9. "J"-flagged data (i.e., values estimated between the MDL and the MRL) are presented on this spreadsheet. 10. "B"-flagged data (values detected in the lab blank) are laboratory errors and are presented on this spreadsheet. 14175-05 GW Tables Table 4 VOC April 2021 Prepared By: RLB Checked By: IAI Table 5 Groundwater Field Parameters and Total Metals Old Buncombe County Landfill Woodiin, North Carolina Permit No. 1101-MSWLF-1979 BLE Project Number J21-14175-05 Sam led by Pace Analytical Services, LLC. April 28-29, 2021 TEST UNITS MRL MDL MCL MW-B MW-2 MW-3 MW4 MW4A MW-5 MW-6 MW-6-192 MW-7 MW-12-25 MW-13-35 MW-13- 132 MW-15 MW-17-60 MW-17- 137 MW-17- 310 MW-18-78 MW-19-75 MW-19- 110 MW-21-21 MW-21-94 MW-24-45 MW-24- 160 DPL-1 pH S.U. >6.5, <8.5 6.8 6.1 6.3 5.97 6.11 6.4 6.1 6.29 5.7 6.6 5.9 6.8 12.82 6.9 7.4 8.5 6.3 6.3 7.5 6.4 6.7 Dry 7.39 7.2 Specific Conductance mmhos/cm NE 699 135.7 1450 1050 683 1490 1473 473.1 262.2 523.7 340.7 374.0 8058 606 824 144.9 1020 1180 459.7 1580 902 Dry 213.2 1675 Temperature °C NE 16.9 21.4 21.8 18.8 22.3 19.1 23.5 18.9 15.9 16.5 17.1 26.2 18.1 20.8 15.9 24.7 15.7 20 16.8 17.1 16.9 Dry 19 30.2 Turbidity NTU NE 9.8 8.7 5.9 2.02 5.67 1.1 0.9 3.73 9.3 1.4 2.4 7.4 2.86 4.1 0.7 3.2 4.5 0.5 0.7 4 0.1 Dry 8.08 9.9 Dissolved Oxygen (DO) mg/L NE 0.1 5.3 0.6 1.03 3.76 0.3 0.5 0.66 0.1 2.8 2.7 0.8 5.37 2.7 0.8 0.4 1.5 0.8 0.6 0.1 0.2 Dry 1.49 1.7 Redox mV NE -133.3 44.2 -64.1 -4.7 -29.7 -20 -27.2 40.4 36.6 87.0 105.8 -131.4 -100.1 -71.1 -145.1 64.1 -22 -8.9 -119.4 -60.8 -71.5 Dry -94.4 64.1 Total Antimony (Sb) µg/1 2.0 0.5 1.0 (i) <0.50 1.0 J <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 Dry <0.50 0.80 J Total Arsenic (As) µg/1 2.0 1.3 10 1.4 J <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <13 <13 <13 <13 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 Dry <1.3 <1.3 Total Barium (Ba) µg/1 5.0 1.3 700 290 25 240 630 670 170 1,700 61 180 58 180 41 220 24 24 3.3 J 75 120 11 120 47 Dry 27 85 Total Beryllium (Be) µg/1 0.4 0.15 4.0 (i) <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 0.20 J <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 4.1 J <0.15 <0.15 Dry <0.15 <0.15 Total Cadmium (Cd) µg/1 0.5 0.13 2.0 <0.13 <0.13 0.19 J 0.84 0.18 J <0.13 <0.13 <0.13 0.14 J <0.13 <0.13 <0.13 <0.13 <0.13 <0.13 <0.13 <0.13 <0.13 <0.13 <0.13 <0.13 Dry <0.13 <0.13 Total Chromium (Cr) µg/1 5.0 1.3 10.0 <1.3 2.2 J <1.3 <1.3 <1.3 <1.3 <1.3 <13 <1.3 <1.3 <13 <1.3 12 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 Dry <1.3 55 Total Cobalt (Co) µg/1 5.0 1.3 1.0 (i) <1.3 <1.3 15 76 48 11 <13 <1.3 200 <1.3 1.3 J <13 <1.3 <13 <1.3 <1.3 <1.3 3.4 J <1.3 12 <1.3 Dry <1.3 4.0 J Total Copper (Cu) µg/1 5.0 1.3 1000 <1.3 2.7 J <1.3 <1.3 4.0 J <1.3 <1.3 <1.3 14 1.3 J <13 <13 <1.3 <13 <13 <13 <13 <13 <13 <1.3 <1.3 Dry 1.3 J 5.6 Total Lead (Pb) µg/1 1.0 0.25 15 <0.25 0.77 J <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 0.45 J <0.25 <0.25 <0.25 1.2 <0.25 <0.25 0.31 J <0.25 <0.25 <0.25 <0.25 <0.25 Dry 0.74 J 2.1 Total Mercury (Hg) µg/1 0.20 0.091 1.0 NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Total Nickel (Ni) µg/1 5.0 1.3 100 <1.3 7.5 32 93 9.7 19 11 1.5 J 57 15 4.8 J 2.2 J <1.3 <1.3 <1.3 <1.3 7.2 22 <1.3 4.6 J 8 Dry 1.6 J 53 Total Selenium (Se) µg/1 5.0 1.3 20 <1.3 <1.3 1.9 J <1.3 <1.3 2.1 J 1.3 J <13 <13 <13 <13 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 Dry <1.3 <1.3 Total Silver (Ag) µg/1 1.0 0.25 20 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 Dry <0.25 <0.25 Total Thallium (Tl) µg/1 0.5 0.15 0.2 (i) <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 <0.15 Dry <0.15 <0.15 Total Tin µg/1 20 5.0 2,000 (i) NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Total Vanadium (V) µg/1 5.0 2.5 0.3 (i) <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 <2.5 Dry <2.5 <2.5 Total Zinc (Zn) 10 2.5 1,000 <2.5 8.9 J 25 17 2.7 J <2.5 6.1 J <2.5 13 9.1 J 8.0 J 6.9 J <2.5 <2.5 <2.5 3.1 J <2.5 5.5 J 7.5 J 2.7 J <2.5 Dry 7.2 J 14 Notes: 1. MCL = Maximum Contaminant Level, as established in the NCDENR, Classifications of Water Quality Standards Applicable to Groundwaters of North Carolina, Section 15A NCAC 2L .0202. Updated July 24, 2020 2. (i) = Interim Maximum Allowable Concentrations (IMACs). Updated April 6, 2018 3. Shaded cells indicate exceedances of IMACs 4. Shaded cells indicated exceedances of MCLs 5. NE = Not Established; North Carolina has not established a MCL 6. MRL = Method Reporting Limit 7. MDL = Minimum Detection Limit 8. NT = Not Tested 9. "I" -flagged data (i.e., values estimated between the MDL and the MRL) are presented on this spreadsheet. 14175-05 GW Tables Table 5 Metals April 2021 Prepared By: RLB Checked By: IAI Table 6 Surface Water VOCs Old Buncombe County Landfill Woodfin, North Carolina Permit No. 1101-MSWLF-1979 BLE Project Number J21-14175-05 Sampled by Pace Analytical Services, LLC. April 28, 2021 TEST UNITS MRL MDL NC211 SW-1 SW-2 SW-2A SW-3 SW-4 Acetone µg/1 20 5.0 2,000 <5.0 <5.0 <5.0 <5.0 <5.0 Acrylonitrile µg/1 20 0.80 420.0 <0.8 <0.8 <0.8 <0.8 <0.8 Benzene µg/1 1.0 0.40 51.0 <0.4 <0.4 <0.4 <0.4 <0.4 Bromochloromethane µg/1 1.0 0.40 NE <0.4 <0.4 <0.4 <0.4 <0.4 Bromodichloromethane µg/1 1.0 0.40 NE <0.4 <0.4 <0.4 <0.4 <0.4 Bromoform µg/1 1.0 0.40 120 <0.4 <0.4 <0.4 <0.4 <0.4 Carbon Disulfide µg/1 1.0 0.40 100 <0.4 <0.4 <0.4 <0.4 <0.4 Bromomethane (Methylbromide) µg/1 2.0 0.40 0.04 <0.4 <0.4 <0.4 <0.4 <0.4 Carbon tetrachloride µg/1 1.0 0.40 1.6 <0.4 <0.4 <0.4 <0.4 <0.4 Chlorobenzene (mono) µg/1 1.0 0.40 800 <0.4 <0.4 <0.4 <0.4 <0.4 Chlomethane µg/1 2.0 0.40 NE <0.4 <0.4 <0.4 <0.4 <0.4 Chloroform µg/1 1.0 0.40 2,000 <0.4 <0.4 <0.4 <0.4 <0.4 Chloromethane (Methylchloride) µg/1 1.0 0.50 96.0 <0.5 <0.5 <0.5 <0.5 <0.5 Dibromochloromethane µg/1 1.0 0.40 21 <0.4 <0.4 <0.4 <0.4 <0.4 1,2-Dibromo-3-chloropropane; DBCP µg/1 1.0 0.40 0.13 <0.4 <0.4 <0.4 <0.4 <0.4 1,2-Dibromoethane; Ethylene dibromide µg/1 1.0 0.40 0.1 <0.4 <0.4 <0.4 <0.4 <0.4 Dibromomethane µg/1 1.0 0.40 NE <0.4 <0.4 <0.4 <0.4 <0.4 1,2-Dichlorobenzene µg/1 1.0 0.40 3,000 <0.4 <0.4 <0.4 <0.4 <0.4 1,4-Dichlorobenzene µg/1 1.0 0.40 900 <0.4 <0.4 <0.4 <0.4 <0.4 trans-1,4-Dichloro-2butene µg/1 2.0 0.50 NE <0.5 <0.5 <0.5 <0.5 <0.5 1,1-Dichloroethane µg/1 1.0 0.40 100 <0.4 <0.4 <0.4 <0.4 <0.4 1,2-Dichloroethane µg/1 1.0 0.40 650 <0.4 <0.4 <0.4 <0.4 <0.4 1,1-Dichloroethene (-ethylene) µg/1 1.0 0.40 20,000 <0.4 <0.4 <0.4 <0.4 <0.4 cis-1,2-Dichloroethene (-ethylene) µg/1 1.0 0.40 720 <0.4 <0.4 <0.4 <0.4 <0.4 trans-1,2-Dichloroethene (-ylene) µg/1 1.0 0.40 4,000 <0.4 <0.4 <0.4 <0.4 <0.4 1,2-Dichloropropane µg/1 1.0 0.40 31.0 <0.4 <0.4 <0.4 <0.4 <0.4 cis-1,3-Dichloropropene (-propylene) µg/1 1.0 0.40 NE <0.4 <0.4 <0.4 <0.4 <0.4 trans-1,3-Dichloropropene (-propylene) µg/1 1.0 0.40 NE <0.4 <0.4 <0.4 <0.4 <0.4 Ethylbenzene µg/1 1.0 0.40 97 <0.4 <0.4 <0.4 <0.4 <0.4 2-Hexanone µg/1 10 2.0 NE <2.0 <2.0 <2.0 <2.0 <2.0 Iodomethane µg/1 5.0 0.40 NE <0.4 <0.4 <0.4 <0.4 <0.4 Dichloromethane (Methylene chloride) µg/1 1.0 0.40 1,000 <0.4 <0.4 <0.4 <0.4 <0.4 2-Butanone (Methyl ethyl ketone) µg/1 10 2.0 26,000 <2.0 <2.0 <2.0 <2.0 <2.0 4-Methyl-2-Pentanone µg/1 10 2.0 26,000 <2.0 <2.0 <2.0 <2.0 <2.0 Styrene µg/1 1.0 0.41 NE <0.4 <0.4 <0.4 <0.4 <0.4 1, 1, 1,2-Tetrachloroethane µg/1 1.0 0.40 NE <0.4 <0.4 <0.4 <0.4 <0.4 1,1,2,2-Tetrachloroethane µg/1 1.0 0.40 4.0 <0.4 <0.4 <0.4 <0.4 <0.4 Tetrachloroethene (-ethylene) µg/1 1.0 0.40 3.3 <0.4 <0.4 <0.4 <0.4 <0.4 Toluene µg/1 1.0 0.40 11.0 <0.4 <0.4 <0.4 <0.4 <0.4 1, 1, 1 -Trichloroethane µg/1 1.0 0.40 200,000 <0.4 <0.4 <0.4 <0.4 <0.4 1,1,2-Trichloroethane µg/1 1.0 0.40 8.9 <0.4 <0.4 <0.4 <0.4 <0.4 Trichloroethene (-ethylene) µg/1 1.0 0.40 30.0 <0.4 <0.4 <0.4 <0.4 <0.4 Trichlorofluoromethane µg/1 1.0 0.40 67,000 <0.4 <0.4 <0.4 <0.4 <0.4 1,2,3-Trichloropropane µg/1 1.0 0.40 0.001 <0.4 <0.4 <0.4 <0.4 <0.4 Vinyl acetate µg/1 5.0 1.2 NE <1.2 <1.2 <1.2 <1.2 <1.2 Vinyl chloride µg/1 1.0 0.40 2.4 <0.4 <0.4 <0.4 <0.4 <0.4 Total Xylenes µg/1 1.0 0.40 670 <0.4 <0.4 <0.4 <0.4 <0.4 1,4-dioxane I µg/1 1 3.0 1 1.0 1 80 1 NT I NT 1 12 1 34 1 68 Notes: NC2B = North Carolina Surface Water Standards for Class B freshwater under Title 15A Subchapter 2B. per NC DWR Surface Water Quality Standards, Criteria, & In -Stream Target Values (Workbook Dated 6-10-2019) NE = Not Established; North Carolina has not established a MCL NT = Not Tested MRL = Method Reporting Limit MDL = Minimum Detection Limit " J"-flagged data (i.e., values estimated between the MDL and the MRL) are presented on this spreadsheet. Shaded cells indicated exceedances of NC2B Surface Water Standards 14175-05 SW Tables Prepared By: RLB Table 6 SW VOC (4-28-21) Checked By: IAI Table 7 Surface Water Field Parameters and Total Metals Old Buncombe County Landfill Woodfin, North Carolina Permit No. 1101-MSWLF-1979 BLE Project Number J21-14175-05 Sampled by Pace Analytical Services, LLC. April 28, 2021 TEST UNITS MRL MDL NC211 SW-1 NC211 SW-2 NC211 SW-2A NC211 SW-3 NC211 SW4 pH S.U. (on -site) <6.0; >9.0 7.02 <6.0; >9.0 7.2 <6.0; >9.0 7.65 <6.0; >9.0 7.21 <6.0; >9.0 7.91 Specific Conductance µmhos/cm (on -site) NE 60.6 NE 52.5 NE 407.9 NE 571.8 NE 1473 Temperature °C (on -site) 29.0 16.1 29.0 16.3 29.0 14.5 29.0 15.8 29.0 15.0 Turbidity NTU (on -site) 50.0 10.11 50.0 9.78 50.0 7.82 50.0 35.71 50.0 113.3 Hardness mg/L 10 2.0 NE NT NE NT NE NT NE NT NE NT Dissolved Oxygen mg/L - - <4.0 8.53 <4.0 8.68 <4.0 7.4 <4.0 8.31 <4.0 8.28 Redox mV - - NE 20.5 NE 19.6 NE 46.3 NE 47.6 NE 59 Total Antimony (Sb) µg/1 2.0 0.50 640 <0.5 640 <0.5 640 <0.5 5,300 <0.5 5,300 <0.5 Total Arsenic (As) µg/1 2.0 1.3 10.0 <1.3 10.0 <1.3 10.0 <1.3 10.0 <1.3 10.0 <1.3 Total Barium (Ba) µg/1 5.0 1.3 21,000 14 21,000 14 21,000 35 21,000 110 21,000 120 Total Beryllium (Be) µg/1 0.40 0.15 65.0 <0.15 65.0 <0.15 65.0 <0.15 65.0 <0.15 65.0 <0.15 Total Cadmium (Cd) µg/1 0.50 0.13 0.82 <0.13 0.43 <0.13 2.98 <0.13 4.35 <0.13 8.95 <0.13 Total Chromium (Cr) µg/1 5.0 1.3 183.07 <1.3 100.36 <1.3 616.02 <1.3 879.9 <1.3 1736.91 <1.3 Total Cobalt (Co) µg/1 5.0 1.3 4.0 <1.3 4.0 <1.3 4.0 <1.3 4.0 3.2 J 4.0 Total Copper (Cu) µg/1 5.0 1.3 3.64 <1.3 1.82 <1.3 14.7 5.7 22.16 <1.3 48.45 <1.3 Total Lead (Pb) µ 1.0 0.25 13.88 0.5 J 6.04 <0.25 71.63 <0.25 114.5 <0.25 273.64 <0.25 Total Mercury (Hg) µg/1 NT NT 0.012 NT 0.012 NT 0.012 NT 0.012 NT 0.012 NT Total Nickel (Ni) µ 5.0 1.3 144.92 <1.3 77.88 <1.3 507.55 <1.3 733.54 4.0 J 1480.83 20 Total Selenium (Se) µg/1 5.0 1.3 5.0 <1.3 5.0 <1.3 5.0 <1.3 5.0 <1.3 5.0 1.7 J Total Silver (Ag) µg/1 1.0 0.25 0.3 <0.25 0.08 <0.25 3.79 <0.25 8.01 <0.25 33.42 <0.25 Total Thallium (Tl) µg/1 0.5 0.15 2.0 <0.15 2.0 <0.15 2.0 <0.15 2.0 <0.15 2.0 <0.15 Total Vanadium (V) µg/l 5.0 2.5 NE <2.5 NE <2.5 NE <2.5 NE <2.5 NE <2.5 Total Zinc (Zn) µg/1 10 2.5 36.2 11 19.44 3.9 J 127.04 1.6 J 183.7 <2.5 371.25 <2.5 Notes: NC213 = North Carolina Surface Water Standards for Class B freshwater under Title 15A Subchapter 213. per NC DWR Surface Water Quality Standards, Criteria, & In -Stream Target Values (Workbook Dated 6-10-2019) Measured values of hardness were utilized to calculate an acute standard at each surface water location for metals highlighted in green. Hardness values werereported in Report of Water Quality Sampling and Analysis 1st Semi -Annual Event 2020 prepared by BLE, dated July 14, 2020. NE = Not Established; North Carolina has not established a standard "J"-flagged data (i.e., values estimated between the MDL and the MRL) are presented on this spreadsheet. Shaded cells indicated exceedances of NC213 Surface Water Standards MRL = Method Reporting Limit MDL = Minimum Detection Limit NT = Not Tested DNA = Data Not Available 14175-05 SW Tables Table 7 SW Metals (4-28-20) (2) Prepared By: RLB Checked By: IAI Table 8 Groundwater Transects for Remedial Monitoring Old Buncombe County Landfill Woodfin, North Carolina Permit No. 1101-MSWLF-1979 BLE Project Number J21-14175-05 Transect I Transect 2 Transect 3 Transect 4 1 Transect 5 MW-4A MW-B MW-3 DPL-2 (AB) MW-6 MW-12-25 MW-17-60 MW-21-21 MW-4 MW-6-192 MW-13-35 MW-17-137 MW-21-194 MW-19-75 MW-5 MW-13-132 MW-19-110 DPL-1 MW-24-45 MW-18-78 MW-24-160 Bold - MNA Performance Well AB - Abandonded 14175-05 GW Tables Table 8 Transect Nos. (Spring) Table 9 Groundwater Geochemical Parameters for MNA Old Buncombe County Landfill Woodfin, North Carolina Permit No. 1101-MSWLF-1979 BLE Project Number J21-14175-05 Sam led b Pace Anal ical Services, LLC. April 28-29, 2021 TEST UNITS MRL MDL MCL MW-B MW-2 MW-3 MW-4 MW4A MW-5 MW-6 MW-6-192 MW-7 MW-12-25 MW-13-35 MW-13- 132 MW-15 MW-17-60 MW-17- 137 MW-17- 310 MW-18-78 MW-19-75 MW-19- 110 MW-21-21 MW-21-94 MW-24-45 MW-24- 160 DPL-1 Dissolved Hydrogen (DH) nM 1.9 0.49 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Lactic Acid mg/l 0.50 0.053 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Acetic Acid mg/l 0.50 0.120 5.0 (i) NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Propionic Acid mg/l 0.50 0.053 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Formic Acid 1119/1 0.50 0.055 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Butyric Acid mg/l 0.50 0.058 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry I NT NT Pymvic Acid 1119/1 0.50 0.060 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT i-Pentanoic Acid mg/l 0.50 0.061 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Pentanoic Acid mg/l 0.50 0.056 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT i-Hexanoic Acid mg/i 0.50 0.056 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Hexanoic Acid mg/l 0.50 0.058 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Methane 119/1 5.0 2.5 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Ethane ug/I 1.0 0.075 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Ethene 119/1 1.0 0.12 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Carbon Dioxide (CO2) mg/l 0.9 0.127 NE NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT NT Dry NT NT Alkalinity mg/l 20 20 NE NT 64 NT 450 NT NT 570 NT NT NT NT 150 NT NT NT NT 300 410 170 770 310 Dry 70 NT Sulfide 1119/1 1.0 0.99 NE NT 1.2 NT <0.99 NT NT <0.99 NT NT NT NT <0.99 NT NT NT NT 3.7 <0.99 <0.99 1.5 2.6 Dry 1.8 NT Biological Oxygen Demand (BOD) mg/l 2.0 0.18 NE NT <0.18 NT <0.18 NT NT 6.6 NT NT NT NT <0.18 NT NT NT NT 2.7 <0.18 <0.18 3.7 <0.18 Dry <0.18 NT Sulfate m9/1 1.0 0.2 250 NT 3.2 NT <0.2 NT NT 1.1 NT NT NT NT 7.8 NT NT NT NT 2.2 17 12 23 3.3 Dry 23 NT Nitrate mg/l 0.10 0.025 10 NT 0.027 NT <0.025 NT NT <0.025 NT NT NT NT 0.028 J NT NT NT NT <0.025 0.012 J <0.025 <0.025 <0.025 Dry <0.025 NT Chloride 1119/1 1.0 0.2 250 NT 2.4 NT 0.32 J NT NT 160 NT NT NT NT 5.1 NT NT NT NT 150 150 41 70 98 Dry 6.5 NT Chemical Oxygen Demand (COD) mg/1 20 20 NE NT <20.0 NT 20 NT NT 42 NT NT NT NT <20.0 NT NT NT NT 33 40 <20.0 58 28 Dry <20.0 NT Total Organic Carbon (TOC) mg/I 1.0 1.0 NE NT 11 NT 6.3 NT NT 15 NT NT NT NT 1.1 NT NT NT NT 8.9 12 2.8 15 7.3 Dry 1.4 NT Iron H (field measured) u NE NT ND NT 6,000 NT NT 3,000 NT NT ND ND 6,000 NT 4,500 1,500 ND 5,000 >7,000 2,500 2,500 4,500 Dry 500 NT Notes: 1. MCL = Maximum Contaminant Level, as established in the NCDENR, Classifications of Water Quality Standards Applicable to Groundwaters of North Carolina, Section 15A NCAC 2L .0202. Updated July 24, 2020 2. (i) = Interim Maximum Allowable Concentrations (IMACs). Updated April 6, 2018 3. Shaded cells indicate exceedances of IMACs 4. Shaded cells indicated exceedances of MCLs 5. NE = Not Established; North Carolina has not established a MCL 6. MRL = Method Reporting Limit 7. MDL = Minimum Detection Limit 8. NT = Not Tested 9. "J"-flagged data (i.e., values estimated between the MDL and the MRL) are presented on this spreadsheet. 10. ND =Not Detected 14175-05 GW Tables Table 9 MNA April 2021 Prepared By: RLB Checked By: IAI Figures r O � z A H D 25 � Oss �� 1720 o RI z \1 A1KfN St WFOMCHASE'RD 0 6F Do f ��s 0 CHAD WICK WADE'DR � GGG� O ASAA17 u, .r D - - - Ashelawn Gardens MMemory Q emorial Garden � P ! ti 'S- O BAN l �R ODF'IN 1104si ?0°O G ldvievnob u , ?CH U l/ PRO D _ ench Broad zve z�D 25 gAIA $ C' IOLivette-Cem� fq 70 ry. ® eo 00 3 UA ygNRO AL7li q Ploy �c Q Old Macedonia f Gem. f {(�, 251 N Akp UpLB�N:pR " 3 Bus 23 I 0 1 b OODFIiN r0 N 0 0 m, Q) REFERENCES: Mour USGS TOPOGRAPHIC MAP, 7.5 2000 1000 0 2000 4000 r MINUTE SERIES, WEAVERVILLE AND LEICESTER. NC. QUADRANGLE 2019 APPROXIMATE SCALE IN FEET ;� , DRAWN' KLW DATE: 6-15-21 BUNNELL FIGURE IM M LAMMONS SITE LOCATION MAP CHECKED: RLB CAD: BCOLF04—SLM M ENGINEERING CLOSED BUNCOMBE COUNTY LANDFILL 6004 Ponders Court, Greenville, SC 29615 WOODFIN, NORTH CAROLINA 1 APPROVED: JOB NO: J21-14175-05 Phone: (864) 288-1265 Fax: (864) 288-4430 250 125 0 250 500 APPROXIMATE SCALE IN FEET o�No 00 -'�iht'itttttN�. N PLAN, ACTIVE MONITORING WELLS INACTIVE MONITORING WELLS ABANDONED MONITORING WELLS ACTIVE SURFACE WATER SAMPLING LOCATIONS INACTIVE SURFACE WATER SAMPLING LOCATIONS MW-2 MW-8 MW-9 SW-1 SW-5 MW-3 MW-12-10 MW-10 SW-2 SW-6 MW-4 MW-13-10 MW-16 SW-2A SW-7 MW-4A MW-14 MW-17 SW-3 SW-8 MW-5 MW-18-3 DPL-2 SW-4 SW-9 MW-6 MW-19-4 MW-6-192 MW-20-3 MW-7 MW-20-32 MW-12-25 MW-21-4 MW-13-35 MW-22-78 MW-13-132 MW-22-143 MW-15 MW-23-119 MW-17-60 MW-23-186 MW-17-137 MW-A M W-17-310 MW-18-78 M W-19-75 MW-19-110 MW-21-21 M W-21-94 M W-24-45 MW-24-160 DPL-1 MW-B NOTE: ACTIVE SAMPLING MONITORING WELLS AND SURFACE LOCATIONS ARE TO BE SAMPLED AND TESTED TWICE ANNUALLY. INACTIVE MONITORING WELLS ARE TO BE CHECKED FOR DEPTH TO GROUNDWATER ONLY. *WATER LEVEL IS DEEP AND NOT USED FOR CONTOURING PURPOSES. ** WATER LEVELS COLLECTED BUT NO VERIFIABLE SURVEY DATA COLLECTED FOR GROUNDWATER ELEVATION CONTOURING PURPOSES. NM - NOT MEASURED MW-2® ACTIVE GROUNDWATER MONITORING WELL MW-8® INACTIVE GROUNDWATER MONITORING WELL MW-8 & ABANDONED GROUNDWATER MONITORING WELL SW-1- ACTIVE SURFACE WATER MONITORING LOCATION SW-54 INACTIVE SURFACE WATER MONITORING LOCATION PROPERTY BOUNDARY SURFACE WATER POTENTIOMETRIC CONTOUR GROUNDWATER FLOW DIRECTION 250 125 0 250 500 APPROXIMATE SCALE IN FEET REVISIONS No. DESCRIPTION BY DRAWN: RLB CHECKED: IAI APPROVED: DATE: 6-3-21 CAD FILE: BCOLF-05POT042721 JOB NO: J21-14175-05 BUNNELL � LAMMONS ENGINEERING 6004 Ponders Court, Greenville, SC 29615 Phone: (864) 288-1265 Fax: (864) 288-4430 GROUNDWATER ELEVATION CONTOUR MAP — APRIL 27, 2021 OLD BUNCOMBE COUNTY LANDFILL WOODFIN, NORTH CAROLINA FIGURE NO. 2 APPENDIX A FIELD SAMPLING LOGS PACE ANALYTICAL SERVICES, LLC. aceAnalytical PACE ANALYTICAL SERVICES, LLC 106 Vantage Point Drive • West Columbia, SC 29172 Telephone No. 803-791-9700 Fax No. 803-791-9111 www.pacelabs.com Number li ''D> 3" Client Report to Contact Telephone No. /E-mail No. " Address Sampler's Signature Analysis (Attach list if more space is needed) i € X Pa gei of 4 city State Zip Code '� �_;.� Lot # Bar Code -. Primed Name (lab use only) Project Name e ^� Pmt No 1 - ^ ✓ P.O. No. = Matrix No of Containers `; ~ j 8 by Preservative Type Sample ID / Description ColleGicn Collection Time z i g2 Remarks/Cooler I.D. (Containers V each sample maybe combinad on one fine.) Date(s) (Military) y g j �— e t � — —i, .3 . I FUT Turn Around Time Required (Prior lab approval required farexpedifed TAT.) Sample Disposal Possible Hazard Identification OC Requirements (Specify) E. Standard - Rush (Specify) ❑ Return to Client ❑ Disposal by Lab ❑ Nan -Hazard ❑ Flammable a Skin Irritant ❑ Poison ❑ Unknown 1. Relinquished by t t- r Date Time ''�� 1. Received by Date Time t 2. Relinquished by Date Time 2. Received by Date Time 3. Relinquished by Date TIM 3. Received by Date Time 4. Relinquished by Date Time 4. Laboratory received by Date Time Note: Ali samples are retained for four weeks from receipt LAB USE ONLY Temp Blank t? Y ❑ N unless other arrangements are made. Received on ice (Circle) Yes No Ice Pack I Receipt Temp. "C DISTRIBUTION: WHITE & YELLOW -Return to laboratory with Sample(s); PINK-Field/Client Copy Document Number. ME003N2-01 Document Nam: Field (lata Shcet -. Date Issued: March 8, 2019 Page: 1 ofZ aeeatalNic�it- Dmument Number F-CAR-Ft pA01-rev.Q') Issuing Authority; Pace Huntersville (7uality Office Field Data Sheet nt.,QL ^ Bu AC. CO. Location: Wy >;a�,tiie Project#: BunG . Go G(oSP� L F Wea,5' Name and Affiliation (Sampler(s);,Ans - J 0.Co _ Field Data Sheet Reviews Name and Affiliation (Inspector): Al A Date: +d4'r7l By: $RG- Well Informations Well ID: i - i Well Locked: YE / NO / Flushmount )' Well Diameter: Construction: ( Steel/Stainless Steel) Total Well Depth: 6 C' 0 it Multi Flctgr*: V , C(Radius/12)2 x 3.14 x 7.481 Static Water Level: 65- O 5 ft Casing Volume: 0 ,163 gallons Height of Water Column, I.Oa it CaL 3 Volumes: 0.Ljggallons Pump Intake: 66. 0 ft Pure Information Date Purged: OBI / lg /_Start: t315 Finish: IS 10 Purge Rate: 5 nt,CIry t+\ Purging Method: IA qua mor i oars 0. Total Volume Purged: 2 5 (gallons/(9L) Sampling Information Date Collected: 04 / / t32) Time Collected: I rL- _ -(am/ 09 Sampling Equipment Used: (A"o.rnovnSvmrt /(instrument ID: V 3�/ � ipt Jl�Sai3 Bottle Type Preservation Analysis Required Ix 25o yy/ t. Paps+-; Cnuc fops M4,60.15 3X90 M L- V1,00 HG I Ale ArJP Z VoC. ZxNo m 1- L 0.1 /-I G l 114 D olCo t �L Field Measurements/Observations Sample Temp Cq: 3 0 - 2 Time:51-5--._ Turbitity (ntu): 9 . a) Time: 1 9;1 5 Diss Oxy (mg/L)r 1 - "�' Time: 151 </ Fe 2+ mg/L: Thne: — Specific Cond', (uS): I6 k 5 Time: 1515 Res. Cl (mg/L)/(µg/L): Time: Sample pH (s a ). Z_ Time 15 15 Odor:__ Ak%J Time: I I ReDox (mV) i4t • Time: I Appearance: Cloudrime: I S 15 ReDox (EH value):YSI ProPlus +200mV j 6u . ( Other: Time: General/Weather Observations: ()?I. - 1 . _ um cloudy/rainy) Temp.'KC (OF) Wind Z- 5 (mph) Sampler Signature: Stabilization Test Time Purged T onlp. (C) Diss Oxy. (lug/L) Spec Cond. pI3 (s.u.) ReDox (mV) Turbidity (ntu) Volume removed (gallons ml Water level Other (US) (£t) L 1320 ?.2- I-q i n -f.Z `I►-5 S. j 1Z5 65.3 -1. 91- 1-40- q3-Z It-I.9 75 5.3 HSoU- -0 -t I 0 Z 2.y 57-q 6Z5 ,16 fib.$ Z•1 6�D - ti -5 77 65-3-+ Document Issued: March 8, 2019 Document Name: F-CAR-FLD-ODI.rev.03 Pare Huntersville Quality Office Client; Location: project Reviewed Date and BY: +A-ai pw, Stabilization Tes 2.6100 Time Temp. ISS OXY Spec. Cond. pH (s.u.) ReDox (MV) Turbidity Volume Removed (gallonsQL) Water. level (ft) Other or z Document Name. Field data Sheet Date Woe& Much 8, 2019 68f1Jh?lyllCRl Page: 1 of _ Document Number F-CAR-FLD-001-rev.03 issuing Authority: Pace Huntersville Quality' Office Field Data Sheet NameandAffiliation (Sampler(s):z:Y- R cs A C4 ,A Name and Affiliation (Inspector): nil A Well Information Well ID: M W - 3 Well Diameter: Total Well Depth. qS • Oq it Static Water Level: (7 S I SCA ft Height of Water Column: F1 5'J ft Well Locked: l.F' A 1) or t aoa-c yid Data Sheet Review: Date: t(_ a $ -aj By: BRG Construction: ('1�/Steel/Stainless Steel) Multi Factor*:W1.3 (•(Radius/12)2x3,14x7.481 Casing volume: gallons Cal. 3 Volumes: gallons Pump Intake- ��'S� tt Purge Information Date Purged: O1 A / 17 / j_ Start :) t i Q`5_ Finish: Purge Rate: 10 O c n m r\ Purging Method: 3)PA1ccx -ed ��b Total Volume Purged: DQOO ml (gallons /L) Sampling Information Date Collected:/--&f IS Time Collected: ) "�!_q _ (am/ m Sampling Equipment Used: lcd� c—+ed �?LAm0 Instrument ID: 4SL�co�lusib(� Ol,�l!1)ccgzpWtt 3� Bottle Type `AOcY)L S na tc Field Measurements/Observations Preservation "Nos Sample Temp (aC): a\ _7 __Turbidity (ntu): DissOxy (mg/L): Q , � Time: t " l 0 Fe 2+mg/L:_ Analysis Required Nc A pP T- onc_tAks-_..__... N.,c A 9(2 ryo C_ ) . `-I Dc o,cc,. _ Time: Time: Specific Cond. (uS): I l S Q Time: I `-130 Res. Cl (mg/L)/(ltg/L): --Time: — Sample pH (s.u.): 6 3___.. Time: I "A 30 Odor:_,_.. _.. (�1�.__� Time:..__t 130 _ ReDox (mV): 6L� , \ Time: l `1 O Appearance: C. I —0 s Time: ReDox (EH value):YSI ProPlus +200iuV l� Other: -- Time: General/Weather Temp._tj:fA_(°F) Sampler Signature Stabilization Test Time Purged Teemp. (C) Diss Oxy. (mg/L) Spec. Cond. (us) pH (s.u.) ReDox (m Turbidity (ntu) Volume. removed n1V) (gallons / L Water level (ft) Other \\9 DI) ,-V . b I�tti &3 -s$,ro Ie. (. bro,�g D,a'l 016 53.8 •$ Document Name: Field data Sheet re,•�rvayFnal' lssuinl Document Number: F-CAR-FLD-001-rev 02 1 of office Location: 13 e%✓Lv M Q 5 LC01x5n F' /Liri''l l.11C1LL. Name and and Affiliationampler(s)i P2 J lei Field Data Sheet Review: Name and Affiliation (Inspector}: Date: 1, d$ off) By: Well Information well ID: r✓l w - 4 Well Locked: / NO) Well Diameter: 2 Construction: (KV/Steel/Stainless Steel) Total Well Depth: ft Multi Factor*: `," @(Radius/12)2x3.14x7.48I Static Water Level: 6 • L ft. Casing Volume: % 7S2 > > gallons Height of Water Column: CO 1' I ft Cal, 3 Volumes: 1,R 5 gadloi)s Pump Intake: ?J ft PurQo Information / Date Purged: . / a? /1 I Statt: Finish: �� Purge Rate: ©o 1-1 r i- Y-z4"-^ Total Volume Purged: S p.70 (gall° mis) Purging Method is-4l w g Sampling Information Date Collected: Time Collected: �S (an / n/ Y3 ;� Sampling Equipment Used: U6I( IV '2-1-9 Instrument ID: Bottle Type Preservation Analysis Required IA/'°a M��L'/) 3 A(r,L Vo � . Field Measurements/Observations J d > Sample Temp (°C)�Time: / 1FS: Turbidity (ntu): • : — Time: = Diss Oxy (mg/4 3 +7 6 Time: N-1' Fe 2+ mg/L: me: Spec fie Cond. (uS): 8 Time: / 4-, ' Res. CI Sample pH (s.u.): �l Time: f Odor: Nd yr Time: /0-f- ReDox (mV): a4 Time: / f' Appearance: 6-1-4gs Time: ReDox (EH value)`.YSI ProPlus +200mV 1. 3 Other: -� GeneraVWeather Observations�t^/a,,'cM /cloudy/rainy) Templ WindO./a (mPh) Sampler Signature: 11 ✓GL ' Date: Stabilization Test Time Spec. Temp. Diss Oxy. ReDox Turbidity Te Cus) PH (s.u.) (MV) (ntu) Volume moved Water Other level (ft) Purged u m L ( ( C) ( g/) allons mis (g / ) 731� S.9Lf r2 0 3.6� /00j 14'f RAJ, 1. s • 94- "Fl I.7 �ix�3 c7? �.Ofi �6.6 d? �a'oo 66,37 lso -at,e P 3o 6,0 '0 .b�. Document Name: Document Issued: November 27, 2018 Field Data Sheet page&f )- - Document Number: Issueing Authority: F-CAR-FLD-OO1.rev.02 _ Pace Huntersville Quality Office Client: �r Location: Q✓ con Q6 Project: L/LL, 0 a F 0 Reviewed Date and By: Stabilization Test r Iffell Ma=ste Ifuldp1icatfmn.l'.atb=--F 12 I)-. IS: 0.56-70 { 4 A 0 1.0 2 610c Time Purged Temp. (nC) Diss Oxy. (mg/L) Spec. Cond. (u5) pH (s.u.) ReDox (mV) Turbidity (ntu) Volume RemovedWater (gallons/mis) circle one level (ft) �%'Ti3'ry Other G,F? d.o2 —) 6r o 8,1�` 35- o a 6E� G.32 76) 0,90 a:LF � PaCeAvh7lyflc8f Document Name: Field data Sheet lute Issued: March e8, 2019 Pa . I of y'1' $ ' Document Number F-CAR-FLD-061-rev.63 Issuing .Authority: Pace Huntexsvil7Q Quality Office aid be aoa, Name and Aff illation (Sampler(s) t2!jT " 1 1ZCC Name and Affiliation (Inspector): A Well Information Well ID:, MW '" Jr Well Locked: Well Diameter: d t Total Well Depth: '90 Cpv ft Static Water Level: �7- $3 ft Heigl tof Water Column: 3P-t7ft Construction: Field Data Sheet Review: Date:Q 'sS NO / Flushmount) Steel/Stainless Steel) Multi Factor`: • !il-3 r(Radius/12)2 x3,1$ x 7.r181 Casing Volume: 5 •;� gallons Cal. 3 Volumes: f Jr. (o gallons Pump intake: X ft Purge Information p DatePurged:�/ ax / all Start: `31� Finish:13S�6 PurgeRate: TOML[ (-ram Purging Methods_zw_� p� Total Volume Purged: `�QSC) (gallons/01.) Sampling Inform'' ation 4 Date Collected: /A/ a 1 Time Cotleeted:_Aab- 5 (am/(& Sampling Equipment Used: B6�p/erp/e. mv__[nstrumentID: Bottle Type Preservation Analysis Required 5-46r4L Crla�s i{GI Voc 1 �l�;oxaa� t- Q50MC APCi 61 fads Field Measurements/Observations Sample Temp (aC): __• TTime: 3 j_ � Turbidity (ntu): Id Time: Diss Oxy (mg/L): ©• 3 Time: Fe 2+ mg/L: Time: SpecificCoiid. (uS): _,I HR.�_ Time: Ties. Cl (mg/L)/(Itg/L): — Time, Sample pH (s.u.): _�o_ ,Timer Odor:, ��tM cca�S__Time: ReDox (mV): Time; Appearance: GJtqsC rime:_ ReDox (SH valise):YST I?roPlus +200mV [-?O.O Other: General/Weather Observations: Sampler Signature Stabilization Test Time: Temp,__$'(°F) -ak C-35-5- Time Purged g Temp. °C ( ) Disc Oxy. ( n L Spec` Cond. pH (s.u.) ReDox mV ( ) Turbidity ntu o Volume removed aiimTs (g /Q/ Water level Other g/) (us) ( ) (ft) 13PO 6 .3 Q,G k3m 6,5-a-o a, .5 Goo 9. x 7 1.5 1 >' - a,o IGIGO t3 ©•$ 1 9 -la- l .6$ 1333 07. 5 I 14 x q -1 -' 1#3 1 a 00 14-tg Do uunent Narne: Document Issued: March 8, 2019 - aceAnalytical Field Data Sheet Pageaof _o1. Document Number: Issueing Authority ( F-CAR-FLD-001.rev.03 Face Huntetsville Quality Office Client: "T��0.YtcoEflb� Location: "ullle Air Project: &fwrgjr Ca Old LF d6*?-t Well ID: M Reviewed Date and By: Q )Pp Stabilization Test 1.lfe i Diameter Ifultilahcatiort Factoe 1 0.0405 1.2 _ 4.0913 1.625 DAM 2 0.1630 3 0.3670 4 0.6530 6 1.4650 S 2.6100 Time Purged g Temp,Di ( uC) Ox , Y (mg/L) Spec. Cond. (US) pH (s.u.) ReDox (mV) Turbidity (ntu} Volume Removed (gallonsA&L) circle one Water level Eft) Other .3 O -7,a e,.3 190 G, -I6. y7.9 13 L(s n. O 1 C)• 3y 150-S Co. q --a-s I 0-co, M 5,0.0f - " Document Name: Field data Sheet Document Number: F-CAR-FLD-001-rev.02 Field Data Sheet f3LF Location: i0u�ca ln6 ✓{ Office ILOS0617 t.o'1�7 Me✓'1 Name and Affiliation (Samplex(s): NI f J 1 n? 1 ld Data Sheet Review: Name and Affiliation (Inspector):- ----- SDixte:,)e,� Well Information Well ID: %0 G✓ ' 6'/9 z Well Locked: NO) Well Diameter: f7 Construction: (tV /Steel/Stainless Steel) Total Well Depth: K ft Multi Factor*: 1,63 1*(Radius/12)2x3.14x795i Static Water Level: Z • I y ft. Casing Volume: gallons Height of Water Column: �6 f• ? G ft Cal. 3 Volumes: 1, f 9 tF.: {gallons Pump Intake: ] g % ft In Purge I 11 Date Purged: _/ / t / Start: IS J Finish: / ° Purge r r s 11 �a rx ( Total Volume Purged: allons nds) Purging Method, i� g samplingInformation a? 7 Time Collected: Date Collected:_/_/ / Sampling Equipment Used: &i, j Instrument ID: Bottle Type 3 Preservation act /{ci, Analysis Required U> c FieldMeasnrements/Observations . r6 tS 3 �3 /Cf'J Sample Temp (C): Time: Turbidity (ntu): Time: Diss Oxy (mg/L): D , 6,6 Time: 1 d If Fe 2+ mg/L: Time: - -- Specific Cond. (uS): LO 9 • / Time: / 6 1 S Res. Cl (mg/L)/(µg/L): Trim :e �_ Sample pH (s.u,): Zg Time: G S Odor: Mu a- Time: ReDox (mV): ' `F v F Time: (r Appearance: Time: 6 l ReDox (EH value):YSI ProPlus +200mv lJ^ 9' Other. General/Weather Observations• S Uds Y G✓a a M ((Q/cloudy/rainy) Temp. 7S('F) Wind0, r (mph) Sampler Signature Cr_L:95•..�ti.... T /,7/A - Date: �., A?- JS0.Vdd14IXLLor 1 CeRnafyticai' Document Name Field data Sheet Date Issued: March 8, 2019 Page: I of 'p, Document Number. F-CAR-R.,D-p01:-rev.03 Issuing Authority: Pace Huntersville Quality Office r Name and Affiliation (Sanipler(s): y)M —02c2t-' Name and Affiliation (Inspector): Well Information Well ID: M W - % Well Lacked: Well Diameter: a" Total Wel[Depth: a5.3S ro.e £t Static Water Level: ft Height of Water Column; Y- ft Old IF a��1 Field Data Sheet Review: Date:OH�VA By: ES NO / Flushmount) Construction: (E�`,Steet/Stainless Steel) Multi Factor`:.(x(.Radius/12)2x ,140.481 Casing Volume: ^ gallons Cal.3 Volumes: gallons Pump Intake- a�•aS T o. PJft Purge Information qq Date Purged:�/ a$//Ial Start: 1J�1 Finish:16055 Purge Rate: LIJ�M(�(MfN Purging Method:_�ca lzd pi tnQ Total Volume Purged: V7C7 (gallons n /L) Sampling Information Date Collected: _/ al )—t Time Collected: V20__(am/t0 Sampling Equipment Used: D Pu -e Instrument ID:_*Y. Prop�uA 67�Micro r5�� Bottle Type Preservation Analysis Required 5- �OML G�nss IN I�rok f - aSh�aL Plws-h,'r Hdh1C�� �( (�oS htefols Field Measurements/Observations Sample Temp (eC): 15.6 Time: 1700__Turbidity(ntu): ` 3 Time; 00 Diss Oxy (mg/L), 'Tune: Fe 2+ mg/L Specific Cond. (uS): 0(0ca. a Time: Res. Cl (nig/L)/(lcg/L): '1'itne: Sample pH (s.u.); —S �__...._.... .Time: _ —Odor:_ _...._f � ____._._._Time:...-. ReDox (mV): • sP Time: Appearance: �It%r_c�� Time: ReDox (EH value);Y(3I ProPlus +200mV a3ln tC Other: Time: Oenerat/Weather Observations: Temp.7rg ff) Wind t7'S ((mph) Sampler Signature Stabilization Test Spec. Volume Time Purged Teemp. (C) Diss Oxy. (ing/L) Cond. pH (s.u.) ReDox (mV), Turbidity removed (gallons/ Water level ether (US) (ntu) i1 (ft} L (J� •(D Ss rr 7 10 a C)1.616 - MT 5, a. al_r� 11.1 0, I. 5-"i :.s 91.7a- d0.3 0. �)_ alp. �'-7 -71 lXm k l .0 7 al-� Document Name: Document Issued: Match 8, 2010 aceA031WICa Field Data Sheet Page�-of O� 1 Docuritent Number: F-CAR-FLD 007.rcv.03' issueing Authority: Pace Huntersville Quality Office. Client;_ PLE / w-lcQmf,- 6-- Location: i ('�2 Aft: Project: ��Cern C o, Old L F doal Well ID: Mw — Reviewed Date and By: CLA Stabilization Test [Well Diameter R4ultiplication Factor" 1 0.0403 1.2 0.0418 1.625 0.1080 2 0.1630 3 0.3670 4 0.6530 6 1.4630 8 2.6100 Time Purged Temp. (Dc) Di (mg/L} Spec. Cond; (US) pH (s.u.) ReDox (mV) Turbidity (ntu) Volume RemovedssDxy. (gallons s L) circle one Water level (ft) Other iS`tp aGA f3.a 1 ol(5.fo a.(A 76• (o 13,7 3 c� al 7 15'45 ,'3 ;kMO 5,16 5. 00o al.71 15-5-0 %-5- 0•l 9.Q•0 5 G 73,9 30,G 5-49-0 a!•S(* RZtloovh I`J 5 0-1 d3l 5--*7 7r, )L oo as 00 1(6057 fn l• XT 5-7 426- )- ac'a .3 9 a off,16 1(ots 15I 0. P373 5.7 1 Z• 19• a- 13700 aa. si Y-1000 it as i59 0. � a�9.3 5,7 ply-, I-i, 5 Igaoo 9s-70 1 3 (59 0.1 • a 9 37. *7 13. LA as-7oc> -S,, 4 0.1 a14ol5 5-,`b 3(o-3 i0. 7 a7doo I aa.90 5s i . o_t & . 5• 36-1 31700 dJ)J3 z7, Document Name: Field data Sheet Page: I c Art' Yr�7ly¢NU;if Issuing Authority: Pace F Document Number: F-CAR-FLD-001-rev.02 Office L ` Location: i3,•• to n s s, Protect#: C�>Jecd [F AtlI/ Name and Affiliation Name and Affiliation Well lnfformation Well ID: M[s -/d'- Well Diameter: Total Well Depth: 7S, 7 ° ft Static Water Level: 3 �15 ft Height of Water Column:�M• i ft Well Locked: Construction: Field Data Sheet Review: Date: ()`��a ���( By / NO) Steel/Stainless Steet) Multillactoe: ` / 6) r(Radius/12)2x3.14x7481 Casing Volume: d 1• � U %S gallons Cal. 3 Volumes: 3S,0661 9 gallons Pump Intake: ^%0, 0 o ft Purge Itefformatiaxn Date Purged: - / 7R / }' _Stat: tz ti ° Finish: 5 00 Purge Rate: Purging Method:. �0 " Sy�� t Total Volume Purged: A o0 0 (gtaloi'S16 Sanrpl3n� daaferxtaation _ Date Collected: r f / ?! / Time Collected: 17 I (am/(9) Sampling Equipment Used: ' ^a t `F "" " lg used Bottle Tyke y� 3n�s Preservation 6/N�s H�L Maly, s eq //9 C- Field Measixretments/Observati s Sample Temp (C): �T ) Z, I Time: �_7 1= Turbidity (ntu): a Time: Diss Oxy (mg/L): S i Time: y ! � D Fe 2+ mg/L. Specific Conti. (uS): Time: %30r Res. CI (mg/L)/(µg/L)!-'--I'mie: _ Sample pH (s.u.): 7 Time: P 0 a^ Odor: a/0 -e Time: 3 b ReDox (mV): a t 1 Time: o / Appearance: Lw S� < Time: /3of ReDox(EH value):YSIProPlus+200mV �5, /__Pi/ Ste-O Time: /S0 _)Other: General/Weather Observations: 3yd > 6✓n2M y/cloudy/rainy) Temp? r (°F) W ndB /0 (mph) Sampler Signatures Date: 4- SPAMULAUUR 1Go6 Time Temp,Diss Ox . y Spec, Conti. pH (s.u) ReDox Volume Turbidity removed Water Other Purged M (mg/L) (US) (MV) (nti') (gallons/g)- level (ft) �fo li.z 3 a/sj. IF.co -19d,D 3.9 soy s,s� �r l),Z 32 �p151 IJL.eo -toP,� SD S `� 0 "i i /x,2 I�ij (�52geAnaifj,lticalo PACE ANALYTICAL SERVICES, LLC 106 Vantage Point Drive - West Columbia, SC 29172 Telephone No. 803-791-9700 Fax No. 803-791-9111 www.pacelabs.com Number 11,17'913 Client Report to Contact Telephone No. /E-mail Quote No. Address Sample SignIture, Analysis (Attach list it more space is needed) X-'-, Page i of f City State Zip Code Lot # Bar Code Printed Name �111 0 0 we (lab vse only) Project Name V-1 C L Project No., r P.O. No. s Matrix No of Containers by Preservative Type Sample ID Description Collection colkc' m 7ar (Containers for each sample may be combined m me line.) Date(s) (Ma'nu 1 9 ti Remarks Cooler I.D. <I 1--v\ wi — Ll t y 7 V -Z YJ Turn Around 'Thrie Required (Prior lab approval required to r I.VIdifed TAT-) P-o Sample Disposal Identification Possible Hazard Identifition OC Requirements (Specify) ll Standard i Rush (Specify) Return to Client El Disposal by Lab 0 Non -Hazard Ej Flammable '� Skin Irritant C1 Poison El Unknown 1. Relinquished by, Date Tme 1. Received by Date Time 2, 2. Relinquished by Date Time 2. Received by Date Time 3. Relinquished by Date Time 3. Received by Date Time 4. Relinquished by Date Time 4. Laboratory received by Date Time Note: All samples are retained for four weeks from receipt LAB USE ONLY Temp Blank t'5 Y 0 N unless other arrangements are made. Received on ice (circle) Yes No Ice Pack ReceiptTemp. �C DISTRIBUTION: WHITE & YELLOW -Return to laboratory with Sample(s), PINK-FieldCkent Copy Document Number ME003N2-01 ZeAnalyficalo' PACE ANALYTICAL SERVICES, LLC 106 Vantage Point Drive - West Columbia, SC 29172 Telephone No. 803-791-9700 Fax No. 803-791-9111 www.pacelabs.com Number 0 - Client Report to Contact Telephone No. / E-mailNo. Quote L Address Sampler's Signature, Analysis (Attach list If more space is needed) x Page °`" of City state Zip Code Lot # Bar Code Pohlad Name < (lab use only) Project Name J <7,1 Project No. P.O. No. Matrix No of Conlamrs by PesehaWeZTre v Sample ID Description Collection Collection lime Remarks /Cooler LD. (Containers tor each sample maybe combined on one line.) v, I I Z t7 L 7 Tom Around Time Required (Pniarlaftaplinvivirequired fore.Vedfled TAT.) Sample Disposal Possible Hazard Identification QC Requirements (Specify) L Standard !-; Rusk(Spechy) F1 Return to Client D Disposal by Lab El Non -Hazard [I Flammable L-1 Skin Irritant [I Poison 1:1 Unknown 1. Relinquished by ------- Date Timg 1. Received by Date Time 2. Relinquished by Date Time 2. Received by Date Time 3. Relinquished by Date TIM 3. Received by Date Time 4. Relinquished by Date Time I 4. Laboratory received by Date Time I Note: Ali samples are retained for four weeks from receipt —ILAB USE ONLY TempBlank �,Y 11 N unless other arrangements are made. Received on ice (Circle) Yes No Ice Pack Receipt Temp. 'C DISTRIBUTION: WHITE & YELLOW -Return to laboratory with Sampfe(s), PINK-Field/Client Copy Document Number. ME003N2-01 Dmument Name: Field data Sheet Date Issued: March &, 2M I Id ceRnatyticat' Page: I of Document Number F-CAR-FLD-001-red03 lssuing,Authnilty: Pace Huntersville QualityI �r Office Name and Affiliation (Sampler(s):-5;� - e cit- R c al,. Ca, Name and Affiliation (Inspector): /,-31 A Well Information Well ID: M W 7 Well Diameter: Total Well Depth: Static Water Level 10 l ft Height of Water Cotumh:6�'Dcl It L F Ae i a.oa� Data Sheet Review: Date: q - 2�7 - 2-1 By: (rL G- Well Locked: i(UB / NO / Flushniount ) Construction: (Vl V /Steel/Stainless Steel) Multi Factor : 0J1 3 r(RadiusC12)2 x 3,14 x.7.4si Casing Volume: I O , bL gallons CaL 3 Volumes; b3'94 gallons Pump lntlake M,00 ft Purge Information Date Purged:O�-N_/'a-F / aL_ Start: 09S!�7 Finish: ' Purge RateAS-0 mL) Purging Method: I) S D . 136AydR r Total Volume Purged: 3(-) C)C? (gallons nl)/L) Sampling Information Date Collected:_ 101-A t Time Collectedd—CLO-Q,,__ 1u /pin) Sampling Equipment Used: �'�Q 13(Qdde- InstrumerAID: Bottle Type Field Measurements/Observations Preservation Analysis Required NC MNR (zn A Sample Temp (oC): a, . _Time: l Q Q Q Turbidity (ntu): Time: 10 O () DissOxy(mg/L): IS7•3 Time: IOQO Fe2+mg/L tvl� Tune: i000 Specific Cond. (uS): \ 3S 7:1 Time: 1 QQ O Res. CI (mg/L)&g/L): --Time: — Sample pH (s.u.)a---- ___ .Time:, I QOO L (10Q_. _. Repox (mV): "c'1 . �l: Time: l QGC) Appearances Cl eet �A G--&s Time: 100 0 ReDox (EH value):YSI ProPlus +200mV t 1� • -1 Other: Time: General/Weather Wind Q (mph) Sampler Signature: Stabilization Test Time Purged Temp. a (C) Diss Oxy. (mg/L) Spec Cond. u (} pH (s.u.) ,, o�i�ta� ReDax (mV) Turbidity (Diu) Volume removed (gallons/�/ L Water level (ft) Other �0 1, 138,8 "6a L�o,t — y, r3 , L• 4()% o k a b. Lit. .y I Ic�S.lb -- 1•`A 1 S.LVA 0 0 )o8• or Ducument-(same Field data Sheet Late issued: March &, 2019! Pape:. 1 of 1 Document Number HCAR-FL,T7-001-rev:Q3 Issuhig Authority: Pace Htmtersville Quality, Office Name and Affiliation (Sampler(s):-,ZM- aLi A cr c L k62A Name and Affiliation (Inspector): nil Well Inforination Well 1Dt M w - % Well Diameter: Total Well Depth: y1'bQ It Static Water Level; O , 00 ft Height of Water Column: �ft1 6 Q ft Well Locked: Data Sheet Review: Date: 4/'2-9' �-( By: CL.& Construction /Steel/Stainless Steel) Multi Factor*: Q•t 6'> ('(Radius/12)2 x3,14 x.7.481 Casing Volume: /- gallons Cal.3 Volumes; aQ -3LA gallons Pump Intake: -3clQc ft Purge Information Date Purged: q1 lamk_ Start: l�� Q Finish: 11n n Purge Rate: ) `'I Q � Purghig Method: f osla l kt c M,n Total Volume Purged: IA12 can (gallons/ 11s L) Sampling Information Date Collected: 014_/aa l\ Time Collected; Lo S __ (am/ (�m}� Sampling Equipment Used: {�en5lr lkL pU InstrumentID:_'-/&-Z�()cc)()(.,tSi �3Q(,-�i-,ANC.COrQw 30�q Bottle Type Field Measurements/Observations Preservation Analysis Required 1,4Dcokc e car) /\j A Sample Temp (°C): �'J Time: )-�n'�-___Turbidity (ntu): Q - c� Time: YZ)q �— DissOxy{mg/L): Time: JAnl Fe2+mg/Lt 3,Q Time: Specific Cond. (uS): Time: 1 aoS Res. C1 (litg/L)/(Itg/L): --Time: Sample pH (s.u.): � \__.. ,Timet_1�o ReDox (mV): - D� .a Tine: 1 a QK- Appearance: P� Tune: 130 ReDox (EH value):YSI ProPlus +200mV 1--� a .a Other: Time: Wind_O-(mph) Sampler Signature Stabilization Test Time Purged 4Temnp, Diss Oxy. (mg/L) Spec Cond. (uS) pH (s.u.) ReDox (mV) Turbidity (ntu) Volume removed (gallons;'m / L3 Water level (ft) Other 6 a•�I.o (.1 6, I I 1 1 t5TIna I 1 3 1)00 JL1,1 a,3 1 tIt 6•t-'J"l'3 o•q 1-4ao0 &,ri'8 Document Name: Field data Sheet Ig A; rRIYffxV' Name and Affiliation Name and Affiliation (Inspector):__ Well Information Well ID: MhZ n Document Number: F-CAR-FLD-001-rev.02 I office Field Data Sheet Location: CLJ,I� _ Qu�✓ws5e� N� Project#: � �%✓ t?/S `PL- Cr, Field Data Sheet Review: Well Diameter: < Total Well Depth: 6' a!ft Static Water Level: �) • a �— ft NO Height of Water Coln= ��)l ft Date:0L1-0- By: Ih7,5 Well Locked: Y / NO) Construction: Multi Factor': .46) r(Radius/12)2x3.14x7.48] Casing Volume: 0.707j gallons Cal. 3 Volumes: 501 gallons Pump Intake: —7 f' it Purge wormat on Date Purged:. + / � � / R 11 _Stott :�_ Finish: �-'� �Purge Rate: (00 r, Purging Method:.ALg404- G' nv Total Volume Purged: (J_�. (gaUousQ Sampling hefornmtion Date Collected:!-F- /!°/ )L I Time Collected: I / �! (am(p� a ur trument ID: y S NP i fls� l> l sampling Equipment Used: & 6a n 0 ,CIns u 11 Bottle "Type �I—o A t iL9 s .e Preservation /UV N L . yr✓ s Analysis Required n2,�,4 11 Wq It 1 NCB va I,W xd� Field Vieasutevarentls/Observations Temp U Time: Turbidity (ntu): a • 02 Time:! t Sample (C): Diss Oxy (mg/L): f o S Time: I llr o Fe 2+ mg/L: 6 . 00 Time: l - Specific Cond. (US): a Time: L tf 0 Res. Cl (mg/L)/(µg/L): Time Sample pH (s.u.): T r9 Time: j �r Odor: 5 r G N r Time: ReDox (mV): Tine: I y l J Appearance: ReDox (EHvalue):YSIProPlus+200mV j�Other: une: `-' Ceneral/Weather rainy) Temp. Wind D- 0(mph) Sampler Signature: g}�}o�ji'>afiRri TPa$ Q ,,f )i NL Cm // ....�--- Time Purged ---- ---- Temp. (C) Diss Oxy. (mg/L) Spec. Cond. (US), pH (s.u.) ReDox (mV) -- Volume TurbidityWater removed Outer level (ntu) (90ons/ rrils) (ft) ISfb �5)-a� 0 6 Zvi OS los ,o i (3 3� (5.� (�,54 IdsO .5) �- Document Name: Document Issued: November 27, 2018 +' Field Data sheet page?'oE _ Document Number: Issueing Authority: F-CAR-FLD-001.rev.02 _ Face Hunter"e Quality Office Client: IJ Le� Location:CC 03.57o_ 4,- 4 yD tt Project: C L-o t 4 A � MUD: M G✓ ' Reviewed Date and By: t}•(I " of, Stabilization Test f+yrzll �7n�n�?<=x '' i.alr��li�ai�axt F a^�ai�" V _ DANIS 1.623 3 4�i �rs'•<'th 1.46450 Time Purged Tem p (°C) DissOx . y (n-g/L) Spec' Cond. (US) pH (s.u.) ReDox (mV) Turbidity ' (ntu) VolumeRerrroved (gallons circle o e Waterlevel (ft) Other �S`fa: 7 a.o f.>-o i�5 0 3�•47 2.6 /;D. �E7 0� -711L0 o 0 /j.rBG@Ntfy?leal-� t Document Name: Field data Sheet Date Issued: March 8, 2019 - Pa e: I of - . Document Number: F-CAR-FLD-001-rev.03 - Issuing Authority: Pace Huntersville Quality. Office Name and Affiliation (Sampler(s): Name and Affiliation (Inspector): Well Information Well ED: . Mw — V Well Locked: Well Diameter: a t Total Well Depth: a3 ti-0 ft Static Water Level: 347/ 3 ft Height of Water Column: [q .67 ft Construction: Multi _Project #: VWU Data Sheet Review: Date: o ti I3,q I )t 'NO / Flushmount ) ( VC f Steel/Stainless Steel) Jo r(Radius/12)2 x 3.14 x 7.48]. Casing Volume: �, o� gallons. Cal.3 Volumes: ' I- gallons Pump Intake: ft Purge Information %rJ%A _ DatePur ged- / a % /d'i_ Start :13 5-0 Finish: � �a5 Purge Rate: DO6/'tiL /Min Purging Method:otal Volume Purged: '35'415ZD (gallons/4a) CF 06.e/ Sampling Information / Date Collected:/ ppCV� Time Collected: ` a (am/ In Sampling Equipment Used:1NVt5>i.� � fi_uno InstrumentID: � B®-#OA7�'ocj�i/ � 5 Bottle Type M��J PJreservati6n Analysis Required 7� 5 -10 L- ClI4SS d 1cI V© /17,1CMP (- )50,,L NQ03 Field Measurements/Observations Sample Temp (eC): . to e tl Time: ` 6 3( 'Turbidity (ntu): / 0 Time: Diss Oxy (mg/L): n • ( Time: Fe 2+ mg/L: Time: Specific Cond. (uS): CO 9 Time: Res. Cl (mg/L)/(µg/L): —^ Time: Sample pH (s.u.): G . Time: Odor: FOu-k Time: ReDox (mV): — t3-3 • 3 Time: Appearance: Clearw� `nos Time ReDox (EH value):YSI ProPlus +200mV (o(o,7 Other: Time: _ General/Weather Observations: Sampler Signature Stabilization Test /630 _(sunny lon /rainy)) Temp. ?O (7) WindS-!!f--(mph) Time Purged Temp. a (C) Diss Oxy. (mg/L) Spec' Cond. pH (s.u.) ReDox (mV) Turbidity (ntu) Volume removed (gallons/ Water level (ft) Other (US) s IsA ©, '715' 6. _g6 -3-7-Y -;? 5p5/s Ira, pu Mq 0.1 0.5 5-0 9.1s- QL dl,L{ I .o CIS . (� �6.3 10GI I tTsc> 5. LiS B0mdw JLJt5- 01.4 1-7(a I — 9S,(� I d350 5-40 fqI s- 6,9 1 O.co 7c5 .1 1 —8 .(o I lob-r6 1 31i6 16.l$ _� r�c eAnatyfical= Document:Narne: Field Data Sheet Document Issued: March 8,.2019, Pageo,of L- Document Number: Issuemg Authority: - F-CAR F1.D 001.rev.03 Pace Huntersville Quality Office. Client: 13LJF/ d5f!✓k¢v� Location::45l�,,Ye. Project: &Ndyn�, Well ID: MUJ — S ' Reviewed Date and By: Stabilization Test (%Tell fliameter Nfultip]ication Factor" 1 0.04m 1.2 0.0919 _ 1.625 0.108o 2 0.1630 A MI , Time Purged g Temp. o (C) DlssOxy. (mgJl} Spec. Cond. (us) pH (s.u.) ReDox (mV) Turbidity (htu) Volume Removed (gallons I L), circle one Water level (ft) Other 19 19.-7 0- -71-7 (�- - 0 7/. 7 395U I W q S1 iq-4 I&S 709 (o•`7 -97. 3 7 .7 '9V30 $. `f 601U414 1455 1q.5- 0.3 7tl 6. -to(-3 50-s I 1a7so /0.7( 15as 47 0- '7o7 (0."? 17H50 ID.o(� Isis- 16,k 0 6-7 -1r3..8 5-q.5- vb 1so is'aS (0,0 ©-a .Z -u3. 9=S6 d050 (a -DI a50mj Vi3 5 17.0 0.1 9G 6.7 -(Do, 31. I a51-15D iaa 1aS- 6-X 0.1 701 (D-7 -lay 5 as,( a7y5a jp,tq 290M44 1555 t7. 7 0. ( o 2 -1 aS o � I 1 a9 q50 -63 IG05— ITT 0'1 691 31tl970 a0 0A -7 (0.7 0. (0 3 q yS'o )�05- 9. $ �I Document Name: Field data Sheet Date Issued: Mach 8, 2019 /,�/�� .. Page: I of ceAnalyf%ca' - Issuing Authority: acref mtevivi le Quality 1 . Document Number: F-CAR-FLD-001-cev.03 , Office Client: 'B L- Location: 5U� C Project #: �o Name and Affiliation (Sampler(s): C. Field Data Sheet Review: Name and Affiliation (Inspector); Date; oq •21.21 Well Information ui_n in. Yvwo- 12 - rA7a11 T ,:,.Le,i• /I vl]IG, / x1n / FI..°hMnnnr 1 �4 Well Diameter: Total Well Depth: v ' Static Water Level: 7' X2_ ft Height of Water Column: 2�-$`� ft Consttuction: &�_b/Steel/Stainless Steel) Multi Factor*: 01(43 [•(Radius/12)2x3.14x7.481. Casing Volume: gallons. Cal. 3 Volumes: gallons Pump Intake: t;2-9, O ft l jOid Lr' Wv((6 By: WS Puree Information Date Purged: i / 2q ../ . ( Start: 0?00 Finish: Oi�LS Purge Rate: Purging Method: ' Sl�l ` � Total Volume' Purged: 3b e) (gallons i /L) SamplingInformation Date Collected: -q /21/ {j f} Time Collected: 0/pm) l �l �- �� 'i� D/R.i1 � Tfp &o Q Ja Sampling Equipment Used: �-�1, 4 � Instrument ID: Bottle Type Field Measurements/Observations Preservation L4fv03 rEci� Analysis Required Rn-e�� is Il o e, Sample Temp (°C): C S Time: d % % D Turbidity (ntu): Time: Digs Oxy (mg/L): Time: b %p3.y Fe 2+ mg/L: N� Time:. 0936 Specific Cond. (uS): 5z3, % Time Cl L _ 90 Res. Cl (mg/L)/(µg/L)-- '- Time:. Sample pH (s.u.): 47. k' Time: 01036 Odor: VUTY\P- - Time: n %3 0 ReDox (mV): V 2, D Time: O �jV Appearance: Time: 6 � 3 n ReDox (EH value):YSI ProPlus +200mV - O Other: Time: General/Weather Observations: t�/cloudy/rainy) Temp.(°F) Wind--?. (mph) Sampler Signature Stabilization Test Time Temp. Dies Oxy. Cond. pH (s.u.) ReDox Turbidity oume remove Water ether Purged (C) (mg/L) (on) (mV) (ntu) (gallons/ level (ft) fo05 L.(0 `)3,q .5; 60o 7.� -D AR G,, 93.1. 5. 9 -- '7 ff� n tl o 15, 'o, 5' 5th, Gt` '81, 7 2.3 �5i5 I5; 31 U 5z4.5 G�,6 O,K I 14.4 A.9`i•Za. S:z.Y 1 6-6 1 96-0 1 O.` -Z'foo lb Y3 0q)-S li"5 2.9 5a.2,2 &,(e, �ic,2 'R•s' Document Name: Field data Sheet - Date Issued: March 8, 2019 2i racBAfA064fcae - Page: 1 of Issuing Authority: Pamty, Runtersville Quali r . Document Number: F-CAR-FLD-001-rev.03 _ Office N--45" Name and Affiliation (Sampler(s): C-L - P4 c-R., Name and Affiliation (Inspector): . lt,a5 Well Diameter: Construction: dd Data Sheet Review: Date: o44-z41-at By:dQf Steel) Total Well Depth: q©- qq ft Multi Factor*:aft i*(eeRaa'�dius/12)2x3.14x7.48l- Static Water Level: ft Casing Volume: ���— gallons - Height of Water Column N 4✓,3 ft Cal. 3 Volumes: 161 1 Z gallons Pump Intake: ft Purge Information r Date Purged: / Z� ./ ZL� r Start: l!g Finish: / O Z5 Purge Rate: / %r' —,*,Cl v Purging Method: t�l r 5'l r^ 4 C Total Volume' Purged: �a (gallon/L) Sampling Information / 0 3 O Date Collected:/ �y a ( / ( Time Collected: /pm) Sampling Equipment Used: 1 1 % 5 �ti C ('� Instrument ID: Bottle Type Preservatiom Analysis Required c - Asa � �� s F1F/� 3 /'►�t�f�lj -3 - (/v k-xt Uo c Field Measurements/Observations Sample Temp ('C): . % 7 // Time: f a Turbidity (ntu): - t Time:: - Digs Oxy (mg/L): �Z •7 Time: / Fe 2+ mg/L: N J Time: J 03 iS Specific Cond. (uS): yV 7 Time U3 Res. Cl (mg/L)/(µg/L)i '— Time:. Sample pH (s.u.): s.9 Time: > J3�. Odor: �Gtil¢ Time. 103 C ReDox (mV): l o r' g Time: / 0.'4 0 J Appearance: ere r Time: % 03 ReDox (EH value):YSI ProPlus +200mV 3 o 5 • K Other: Time: General/Weather Observations: `/- 21- ZI Stabilization Test Wmd_ —(mph) Time I Temp. Dies Oxy. Spec. • pH (s'u.) ReDox Turbidity Volume removed (gallons/ Water level (ft) Other Purged (eC) (mg/L) Cus) (mV) (ntu) L ©gyv 17.3 / ` 3 5 7 76,g /v,3 6?01 '�.q / DP12 17, 3 1-7 76r Id" r t I. opgSS /7.3 j.Ff 3�jY1 j.'7 77,3 t vv�a 17,3 34o,�t 5,7 -79, 2- / 3, 3 / gvv 7. i7 euv 93,9 7,c1 2goe &.-oy Document Name: Document Issued: Much 8, 2019 Field Data Sheet Page &f — • /�e�Aalytica► Document Number: F-CAR-FLD-001.rev.03 Issueing Authority: Pace Huntersville Quality Office Client: SL-e Location: Project: 0 . CIO 3 Well ID: IW147 —C 3�j Reviewed Date and Bv: 0%-IA �S Stabilization Test t'TW'ell.E?iexa�aL�r PuIvxlt�Tisatia:cB¢cEar" 1 0.0408 I_ 1.2 O.MB 9 1625 GA 2 O.1,65o 3.. O.96311 4 D165."30 1_ M a 2.£r1013 Time Temp. Diss Oxy. Spec Turbidity Volume Removed Water level Dox mV allons,c&L Other Purged (C) (m L (us) circle one IM1 a1'5 1 4 7 2. 3"31l: G S_R tt.,3 ,Z 3tao0 10, 3(O 6 L,?-o LZ, 1 a. '3�16;0 S. j lbu• 0 3,1 2L"v Document Name: Field data Sheet Date Issued: March 8, 2019 J��/ �t'aGBftrwf}cflEal' Page: 1 of . Document Number P•CAR-CAR-001-rev.03 Issuing Authority: Pace Huntersville Quality. t Office . Field Data Sheet Name and Affiliation (Sampler(s): zzg,� - 7a ce A ao, 1 s cQA Name and Affiliation (Inspector): r J IA Well Information Well ID: M (J- 13 13 a Well Diameter: a" Total WellDepth: �3�' ft Static Water Level: ft Height of Water Column: l \ , bSft C.R AeffI aQdA Data Sheet Review: Date: Lf zq - 21 By: GL C-- Well Locked: � / NO / Flushmount ) Construction: (l!V5/Steel/Stainless Steel) Multi Factor*: Q,163 (*(Radius/12)2x3.140.48]. Casing Volume: iB �-O gallons. Cal. 3 Volumes: � L 60 gallons Pump Intake: 131 , OQ ft Purge Information q Date Purged: QH / a� / _ Start: 133 Q Finish: I33� Purge Rate:O Q MU, rm Purging Method: otalVolume Purged: 1300 (gallons/ is L) Samylinglnformation Date Collected: OBI Q A- Time Collected: )3 S9-- (am/ m) Sampling Equipment Used: �?lnstrumentID:_ Y CoP( a.SJ#Q�o6fMrCc6mPw{ 59 Bottle Type Preservation Analysis Required MUFATUMMI v. Field Measurements/Observations Sample Temp (aC : .-0 6 Timer Turbidity (ntu): �_ Time:1 S� Digs Oxy (mg/L):_ 0 -STime: E S - Fe 2+ mg/L 6 , n Time: Specific Cond. (uS):Time, l3Si Res. CI (mg/L)/(µg/L): Time:. Sample pH (s.u.): b ,B Time: 13S c Odor: .. Mihu U s L Time: 1-5 ReDox (mV): 13l , _ Time: 13 Appearance: Q e tr- Time: F:S ReDox (EH value):YSI ProPlus +200mV 68 Other: Time: General/Weather Observations: scan. ( unity on /rainy) Temp.471_(OF) Wind a�(mph) Sampler Signature, Stabilization Test Time Purged em Temp. Diss Oxy. (mg/L) Spy' Cond.PH (s.u.) m;dl�lai ReDox (mV) Turbidity (ntu) Volume removed (gallons m / Water level (ft) Other 3>Q moo a3,ga _� ec a 0--s -1>1.6 ) o so ati.�il 13sa a6.a 1, Q 3�3.3 6.g _taS,6 S''j 13oa au, 63 Document Name: Field date Sheet Date Issued: March 8, 2019 Page: 1of_12— ,. ceAnalyFicai' Issuing Authority: Pace mtersvilte Quality. m . Docuent plumber: F-CAR-FLD-001-rev.03 eH I L-E Name and Affiliation (Sampler(s):�G Name and Affiliation (Inspector): Well Information ML'a-/-2- fob u Well Diameter: p2, Total Well Depth: 111 D' rO ft Static Water Level:_ 3'a - 3 1 ft Height of Water Column:32 � 6 DLit C_ Data Sheet Review: Ca-e-LosR,t' 4 W-e((S. Date: oLi i14-Z( By: V7 Construction: &/Steel/Stainless Steel) Multi Factor*: 0, 163 [•(Radius/12)2 x 3.14 x 9.48). Casing Vo)ume: . l � gallons - Cal. 3 Volumes: `�- gallons Pump Intake: 57 ` S ft Puree Information Date Purged: `' / Start: b Finish: / �50 Purge Rate: PurgingMethod:�?��5�° �hZ Total VolumePurged: ��No0 (gallons/4D/L) SamulingInformation Date Collected: / i5/ 2-1 Time Collected: (am*) Sampling IquipmentUsed: t� Q L tt 0� ` Instrument ID: c>2�3 jew 1b Q 3SS Bottle Type 1= x5D w,,L_ PIez-y 3- 4o ti..L- �Ctis� 02 L10 Iva44.4 Preservation .4,)0 3 14ee Analysis Required Vv Field Measurements/Observations Sample Temp Cq: ' ° li Time: / Turbidity (ntu): Time: Dias Oxy (mg/L): 02 ` 7 Time: Fe 2+ m L: �i Time.. g/ Specific Cond. (uS): (v ° b Time: / Y Res. Cl (mg/L)/(µg/L): `_ Time:. Sample pH (s.u.): c/ Time: 4�56' Odor: "n a_ Time: ReDox (mV): — i!. Time: . / `�� Appearance: Cken c— Time: ys� ReDox (EH value):YSI ProPlus +200mV / Z4; . Other: Time: General/Weather Observations: s /cloudy/rainy) Temp. g (OF) Wind--! z (mph) Stabilization Test Time Temp. Dtss Oxy. Spec. • PH (s.u.) ReDox Turbidity Volume removed (gallons/ xof / Water level (ft) der Purged (aC) (mg/L) S, (mV) (ntu) Aq_-5 2i. �, l 'SG7 7, n 12' 1' aW -z3, If D'.f .2j ,] 1 3, 1 567 7.0 r3if.2 .2, I — l it 30 9.1,3 `f 5'73 `7.' 9.0 Q'-3 S0 �, 57. i 1_b5 11_1.l fit S 3 6,9 63,r} 3, 4 '75a aY,03 p mil, v y aC- r ant 7, a `G j. y '3 / Z) c 1) AY,'1(6 Document Issued. March 8, 2019 Document Name: .� Field Data Sheet Page:! -of 1. esaalyticaf Document Number; F•CAR-FLD-001.rev.03 Issueing Authority: Pace Huntersville Quality Office Client: �iJ L E Location: II Project: E� h r C , e-e . C_(7 S,A LF W-6 Well ID: NL\ 7 ` l7 ` 60 Reviewed Date and By: 04 y71 Stabilization Test ' Z 1 Time Temp. Diss Oxy. Spec. Dox m1 (C (m L (us) KPurged weU.Dfarrmer 1911al i ReaiicMFactor* 3 0.04115 4. i�? 0.0913 ( fi25 CUM 2 0.165m 0,56� 4 0.6 M 1 +4G80 2.6100 Turbidity Volume Removed allons/ , L Water level Other circle one - / l Soo C, 1 Document Name: Field data Sheet Date Issued: Much 8, 2019 - Page: 1 of 1 e:tntt!}Qksf'y Issuing Authority: Pace Huntersville Quality_ . Document Number. F-CAR-FLD-001-rev.03 Office 1 `B LE Name and Affiliation (Sampler(s): Name and Affiliation (Inspector): Well Information wen in. tN\ tn) - ) i - 13 Well Diameter: 1 Total Well Depth: -EY' V ft Static Water Level: 591 ' 5 % it Height of Water Columnl• � ft Construction: Multi Factor*: 01 Casing Volume: ee,. eloseeP L-r Wens Ad Data Sheet Review: Date:a t-%'t - 2-1 By: l Steel) x 3.14 z 7.481. (, gallons Cal. 3 Volumes: ``5 • Y `7 gallons Pump Intake: JJ J ft Puree Information Date Purged: Start: 3 D Finish 9 a Purge Rate:'o Purging Method: `� Total Volume Purged: 320 D (gallons/teL) Sampling Information Date Collected: `�. /2�� Time Collected: 1365 (am/og� Sampling Equipment Used: �Lc«f�La� InstrumentIDY5� A`6--a3 11'"--03s- Bottle Type Preservation Analysis Required vutL 0[evs l�No3 n��ls -s— 40 WtC bt c V LFc� IM,L— `i -AA A CL - t> a -- Field Measurements/Observations Sample Temp (nC): /Time: L �S Turbidity (ntu): 6,7 Timer 1355 Diss Oxy (mg/L): 0." Time: / 355 Fe 2+mg/L: i, Time: 3 55 Specific Cond. (US): TZL Time:. l 855 Res. Cl (mg/L)/(µg/L)i '-- Time:. — SamplepH(s.u.): �'y Time: /355. Odor: k-4� Timei 3 ReDox (mV): r f �S (' Time: Appearance: Time: ReDox (EH value):YSI ProPlus +200m.V Other: Time: General/Weather Observations: Sampler Signature R4u6iti7af-inn Tact Time Temp. Diss Oxy. Spec. pH (s.u.) ReDox Turbidity Volume removed Water Other Purged (C) (mg/L) (mV) (ntu) (gallons, n / level (ft) (u5)Cond TI �3c, -2.S —GG.S 2.3 D 6.7 1,6 5; 3,- 7.5 -GG,S 2-3 aQt.3G f3'(o 1-5,1� 0,7 235. 7. ^I31, 2. ©, V 000 3-1 51 Document Name: Field data Sheet Date Issued: Much 8, 2019 Page: i of Z .racefF/uHyFfCaTf' Issuing Authority: ce untersville Quality. Document Number: F-CAR-FLD-001-t".03 Office L� Name and Affiliation (Sampler(s): 6 -(- 6" ` Name and Affiliation (Inspector): V -ryt� Well information 31 V ®MMF� /V t- Data Sheet Review: Date:644%-zt By:0 Well Diameter: Construction: W/Steel/Stainless Steel) Total Well Depth: 12 ay ft Multi Factor' :O'/&3 r(Radius/l2)2x3.1447.481. Static Water Level: () ft Casing Volume: �!7 1 gallons. Height of Water Column�0 --2y it Cal. 3 Volumes: E S L gallons Pump Intake: -JyS • O . (t z_F Rk Purge Information / — .i ./ Z` Start : %l n S Finish: 13 05 poxge Rate:2'� 0 ,4/L Date Purged: Purging Method- c Total VolumePurged: 1/250 (gallons/&/L) Samuline lnformatiort <— Date Collecfed:. `t /-?�- 1 Time Collected: / / Ul, a m) SamP • lireg Equipment Used:- t i r 5� �C InstrumentID:7 e2®3 IPi O'3ys . Bottle Type Field Measurements/Observations Preservatipn MCC - Analysis Required Sample Temp (oq °Z �'% Time: 3/ / D Turbidity (ntu): 3, Z-� Timer f 3 / J . Diss Oxy (mg/L): 0 .w Time: / 3 / D Fe 2+ mg/L: ✓vim Time: ! 3l o Specific Cond. (uS): Time:, ! �! a Res. Cl (mg/L)/(pg/L): '-- Time:. Sample pH (s.u.): S Time: / 3 / Odor: LUti Tune: ! 3 Ia ReDox (mV): G Y; ( Time: 3 10 Appearance: C.1 t Y+ Time: / ReDox (EH value):YSI ProPlus +200mV 2 Lc( / Other: Time: General/Weather Observations: . su y/cloudy/rainy) Temp.(°F) Wind !3 (mph) Sampler Signature: e Date: z 2-6 z / Stabilization Test mp. Diss Oxy. Spec. Cond. pH (s.u.) ReDox Turbidity Volume removed Water Other C) (mg/L) (US) (mV) (ntu) (gallons/ 1A level (ft) ,o . /0Uv 6,,cj-.�L4 6�rl7t,t 2�U6� 0, . Dk5 /tf1z �,G ss�t.v"{.I 0,5 1 q2,Y I T,y 5.o I 3,I yvoL7 ?,1 f /001-�) , 2019 �'-ac�l�rlalyticaly II Document Name: Field Data Sheet Document Number: F.CAR-FLD-OOl.rev.03 ��cLocation: Nc— Project: _ �hG . Co,ry . CG D � L C l,J•eUs . ' � Well ID: LJ — 17 ` z,/D Reviewed Date and By: -- Stabilization Test FegeZof�-Z- Issueing Authority: Pace Hunteesville Quality Office Wall. Dfamster 1.2 1:629 3 4 fn 3 ic,M l/Sn Fac0M,* 0-ID4 3 O:O912: 0.1.0- 0 t4..1fiSD O.�•Cs7O Ofi5sO 1:�690 2.61O3, Temp. (00 Diss Oxy. (mg/L) Spec. on Cond. (USPurged pH (s.u.) ReDox (mV) Turbidity (ntu) Volume Removed (gallons,/L) circle one Water level (ft) Other Time o'-r.. D l4),(-/ (°>.N 9n,s �3,y oLLtt) oLt{ b a .'-( 0,`I Q`f ©,y o,y 0.� D.{ iYz_3 t<t3,i luz. tyZ1 f`1E.9 t�(�( 3 14qq .z gILLV 13.6y Tr C b,6 r �S,S er, 5Gas D. '7717 7 ti-T -7a_3 (o(e v �, S' 3. 2- 3, 5 �,� iatl 3,l P000 v gvvo R oo �050, 2lv Gt:->50 IR �I ib S 13.ii� l�,l 17. 56 /vr•aa lR. ! q2-. ��✓�Q l 2a� D C2tO /z40 7z3� tiGa iZSv /30v - �./I Document Name: Field data Sheet Date Issued: March 812019 Pa rawrvw yrwai Document Number: F-CAR-FLD-001-rev.03 Issuing Authority: Of untersville Quality. . Field Data Sheet Co red L F wa[5 Name and Affiliation (Sampler(s):s-1D5 - tiz- Q Field Data Sheet Review: Name and Affiliation (Inspector): Al te-- — r� Date: Y-ag-d l By: Q �� Well Information Well ID: PMW WellLocked: E NO / Flushmount ) Well Diameter: a�� Construction: ( Steel/Stainless Steel) Total Well Depth: -46 . 60 ft Multi Factor*: d.. (6 3 [•(Radius/12)2 x 3.14 x 7.481. Static Water Level: - Q ft Casing Volume: I I -3%,J gallons Height of Water Colum� n:_ft Cal. 3 Volumes: 3 (- I X gallons Pump Intake: 7 Lt ft Purge Information / ^' OStart: � DatePur Purged: � �1 . q3� g mL�VYI1t� g _L/2Finish: 10(7�i Pux eRate:P(X9 Purging Method: P�.S I :C Total Volume Purged: -:W0 (gallons/4�L) Sampling Information Date Collected:0 � pj .2011 Time Collected: 1610 (0/pm) Sampling Equipment Used: PQt I S-h:.I1-?C R- nrInstrument ID:� ST 33°/�Ti�f�l 7�3 Bottle Type Preservatimn Analysis Required MtJ Pr be f � Ne- adsyoc NC-, r+p0ss- 15 Field Measurements/Observations Sample Temp (eC): 15 -"� Time:(010Turbidity (ntu): C2 ( O Time: WO Digs Oxy (mg/L): (• 5 Time: sole Fe 2+ mg/L: 6-0 Time; (O ( O Specific Cond. (uS): 10 20 Time:. (G 10 Res. Cl (mg/L)/(µg/L): Time:. -- Sample pH (s.u.): 6.3 Time: 1010 Odor: t95» Time: I 0 f U ReDox(mV): —22-0 Time: (010 Appearance: Ll Time: M(0 ReDox (EH value):YSI ProPlus +200xnV ) 7g. 0 Other: Time: GeneraVWeather Observations: M%d - Sampler Signature Stabilization Test (su loudy/rainy) Temp. 7 9 (OF) Wind f- - (mph). nater ON - 2 g - ZarL1 Time Temp. Diss Oxy. Cond. pH (s.u.) ReDox Turbidity oume removed Water Other Purged (C) (mg/L) (US) (m.V) (ntu) (gallons ml / level (ft) y 15-e o. � S9 .3 � L, 1. 1 620 N tc 5. 0 • di cl 6.1 _ 3- f . O — a 15- 1-Li M 17. 0r3 209/0 6, 0 115.4 & 1013 1 61. 3 1-14.6 10,3 1 300 b.10 is . a-5 JtQ15,16.3 -11.5 ©- 7- oo 16J 0 Document Issued: March 8, 2019 Document Name: zof ?� Field Data Sheet Page Document Number: F-CAR-FLD-00I.rev.03 Issuein Authority; g Pace HuntersvIRe Quality Office Client: 191— E - (3, (Nc . C.O • - Location: .Wadd ,f1 NC Project: SV11C-C Cle) S LEE UJeWU5 Weil ID: rA1h), %q - T75 Reviewed Dateand By: Stabilization Test 'elrcll.t:7�n. E-r .._. '�.Irrl�glice'Ricn T' blt".t`"31 .... 1 �2g Bi.17J3:[N a.1�a a 31 0.3 6 r 4 4. OJ 6WO ,6, 1.4680 2.6100 Turbidity (ntu) (gallonsl(BVL) circle one L'6�1't� Y✓• r Y ®�� Y I®® • � ♦ Y . ♦ Y Y i �® pjrl Document Name: Field date Sheet Date Issued: March 8, 2019 Page: a- P�1} eeArkllj4icaf 1 of Issuing Authority: Pace Huntersville Quality. /// .Document Number: F-CAR-FLD-001-rev.03 Office Field Data Sheet Name and Affiliation (Sampler(s): J05 - 0O-CAP— Name and Affiliation (Inspector): /V P( Well Information Weu iD: Mw - I ot . 35 Well Diameter: .f2�tjl Total Well Depth: f 6 �2 ft Static Water Level: �1. 55 ft Height of Water Column: b$ 97 ft Well Locked: Construction: 05zj1-r wu1S Field Data Sheet Review: Date: 1-49-dI By: krl- / NO / Flushmount ) ySteel/Stainless Steel) Multi Factor*: 0. r(Radius/12)2x3.140.481. Casing Volume: I I - I b gallons. Cal.3 Volumes: 33, 4g gallons Pump Intake: 16 -O (t Puree Information Date Purged: O'-I 0 �X(Start : It 0 Finish: IILIO Purge Rate: ZOo m L / v ' , Yl Purging Method: I Y t 1 �u { a ��i C PuTotal Volume Purged: '4000 (gallons/eL) Sampling Information Date Collected: O—t- _/ */ Time Collected: 1_� kM3pm) Sampling Equipment Used:InstrumentID: 4 STiy33°/ I7�1 Ic1°2 3 Bottle Type Preservation Analysis Required WIN /Gf4-- N t_ Uj! Tyo c AJL nwr MrtaiS r� t K Field Measurements/Observations Sample Temp (oC): �-0 •4 Time: (I LI 5 Turbidity (ntu): 0. 5 Time: 111•(Cj Diss Oxy (mg/L): 0.9 Time: 1146 Fe 2+ mg/L: - �- Time: ) l Specific Cond. (uS): 11190 Time:. 1145 Res. Cl (mg/L)/(µg/L)`. — Time:. — Sample pH (s.u.): 63 Time: 1 1 LI 5 . Odor: MO Time: 1 t S ReDox (mV): — si. �1 Time: 11 t.1 5 Appearance: C (Cay Time: I LI y ReDox (EH value):YSI ProPlus +200mV Other: Time: General/Weather Observations:.FA(k-%w-1 sut f cloudy/rac y,) Temp.(°F) Wind L(1 Sampler Signature: Date:0�1 Stabilization Test Time Temp. Diss Oxy. Spec. Cond.PH (s.u.) ReDox Turbidity volume removed WatflrOffier Purged (°C) (mg/L) (mV) (ntu) (gallons level .)6 1210 6, - .5 D,6 roar 9-S121U _3 -5,i. (3,t 1t s 1 . �1 Iat 3 ��. 0 0.'� zv0c tIZU lb•b I-Z 1►q`I b- -9. 0.6 ;oore 1117 16. IIaD it,. 1 3 1- t.L 10.3 1 g0tt) Document Issued: March 8, 2019 Document Name: 2. Field Data Sheet Paget -of 4 �C.,7�lyliCi` Document [Number: F-CAR-FGD-001.rev.03 Issuein S Authority; Pace Huntersville Quality Office Client: Bar - 17JnC_ Co, aGl Z9.2� Location: W ooAC'n. 161 G Project: Bt1OG CO GIOS<d 1-1r WQ.IIS Well ID; MW - Iq - }y Reviewed Date and Sv: N"a9 "a� i m6c Stabilization Test R�?4f'ed1.E}iazaz=tea•.. hIwlti�pltt�....".-,..-,..__z_,...r . alianPaaboa" 01660 4 D.fi5 rD 6 1 463'0 1.6100 Nell Spec Cond. I Turbidity (ntu) IN MI circle one Document Name: Field data Sheet Date Issued: March 8, 2019 Ce.1lk?l}-Elsafy •. Page: 1of Number: P•CAR-CAR-001-rev.03 Issuing Authority: Pace Huntersville Quality. Y t .Document Office Glased LFwelt5 Name and Affiliation (Sampler(s): _N DS' - PG CO— Field Data Sheet Review: Name and Affiliation (Inspector): NAB- y Date: �j J9 d( By: Well Information 14QRfr Well ID: ./A W '. 0 Well Locked: (QD NO / Flushmount ) Well Diameter: 2 Construction: (I S? teel/Stainless Steel) Total Well Depth: I I �% ft Multi Factor*: 0.1 3 r(Radius/12)2 x 3.14 x 7.48] Static Water Level: IC) . Z �J ft Casing Volume: 1b A5 gallons Height of Water Column: (a • 2- ft Cal. 3 Volumes: gallons Pump Intake: l l 1 . ft Purge Information Date Purged:_ C4 ) start: % Z 4 5- Finish: 130J Purge Rate: 20 0 rNU nn Ul, Purging Method: PPS S'-4c- fume Total Volume Purged: 9600 (gallons/&L) Sampling Information ,, �� Date Collected: Da /�._ nTime Collected: 0o (am/em Sampling Equipment Used: PU t�� Irtl�S�Yog'CoInstrument ID: V 57=�6530ii /rT�in�6U Bottle Type Preservation �equired ,Soy-Z 9•tdtl MO N K1+ nfc �CpT MGf;s.lS fyc A-PQ I V Field Measurements/Observations; Sample Temp (eC): 1 & • D Time: (31 o Turbidity (ntu): (2• % Time: 1310 Diss Oxy (mg/L): 0 • b Time: 130 Fe 2+ mg/L: 2. 5 Time: 13 I G Specific Cond. (uS): C1461A Time: t3i O Res. Cl (mg/L)/(µg/L): Time:. — Sample pH (s. u.): 1.5 Time: 13(0 Odor: . F&,I_ Time: 1310 ReDox (mV):—119.4 Time: (3 U) Appearance: (?.ar Time: '3 ld ReDox (EH value):YSI ProPlus +200ntV �i0. 6 Other: Time: General/Weather Observations: fv -w - Sampler Signature Stabilization Test G•2 Wind 1323(mph) Time Temp. nC Diss Oxy. Spec. Cond. pH (s.u.) ReDox Turbidity oume removed Water Purged ge � ) m L ( g/) (US) m ( � ntu ( ) lions is (ga / level(ft)Other (150 3,7 El sg-0 -f-, `I -0.q 7.7 rorx> I (7 z 6 S4 t -'4 0. I c156,"� 'T• 5 HIS. � A 2evv 10. 2 u (/ -14 0.1 6�. 1 1- • s -116. 5 0 . o 13 _0 H51. 11, .6 n Document Name: Field data Sheet Date Issued: March 8, 2019 aC@rinafpFkaly Page: I of Number: F-CAR-FLD-001-rev.03 - Issuing Authority: Pace Huntersville Quality. t .Document Office . Name and Affiliation (Sampler(s): 'Vp0 " Name and Affiliation (Inspector): Iva Well Information Well 1D: MW- W " 1 WellDiameter: a'' Total Well Depth: ft Static Water Level: ft Height of Water Column:- , 36 ft Well Locked: Construction: Multi Data Sheet Review: Date: o lll� By: ' NO / Flushmount ) eel/Stainless Steel) r(Radius/12)2 x 3.14 x 7.48]. Casing Volume: 3,0 gallons Cal. 3 Volumes; ` /,D gallons Pump Intake: } a 1 ft 0/0/ L)rCtf)/ Purge Information �q _ / Date Purged') a/ ./ ai Start:�Finish: lal� PurgeRate:R M'• M Purging Method: leYiSI��C �� Total Volume Purged:d (gallonsJ'L) Samnlinir Information Date Collected: Time Collected: IaaO (am/ m) Sampling Equipment Used: f P n`g 1'�ll; fp it,(, ID: I Ev te.5a' Bottle Type Preservation Analysis Required MNA Field Measurements/Observations Sample Temp (°C): . 17> Time: l a Turbidity (ntu): qa ® Time: (;) D-a Digs Oxy (mg/L): 0. ( Time: Fe 2+ mg/L: a, 9 Time: Specific Cond. (uS): I5W Time: Res. Cl (mg/L)/(µ /L): Time:. Sample pH (s.u.): Ll . Time: Odor: Time: ReDox (mV): 00,% Time: Appearance: Clear- Time: ReDox (EH value):YSI ProPlus +200mV 13 % Other: Time: General/Weather Observations: LolleAka, l itvr. 4nr HVdaAm a5,tba -, = _(sunny/ ou rainy) Temp. ?7 (°F) Wind � /a (mph) Sampler Signature: ZLI.4 - -A Date: 1 ag a( Stabilization Test Time Temp. Diss Oxy. Spec. PH (s.u.) ReDox Turbidity o ume removed Water Other Purged (oC) (mg/L) (US) (mV) (ntu) (gallons/ nO/ Ll level (ft) ly5 [Tb 11 I In3 to. -5o•i �,7 a� $-!(o fb yr \7.S IA (5q3 --50.0 9.16 aoco 9 G 155 1 119 1 0-6 lsvb (.O,q -sa,q a,s 100c) 19A0 Z05- L\ 0.1 191 (o' q I _-s 9 1 3• I (acco 11. -la (D`iO 17. (.. l .I 1 3: ( I .7oo q,-)L lat5 11.t Q,l ("0 in-t-1-(Do.r{ Li-i saga q.cj2 Document Name: Field data Sheet Date Issued: March 2019 B fJ'Ek y Page: 1 of _ Number: F-CAR-FLD-001-rev.03 Issuing Authority: Pace Runterwille Quali 4'- t .Document Office . LG doDt Name and Affiliation (Sampler(s):_ ik Name and Affiliation (Inspector): 40 Well Information Well ID: Well Diameter: a t Total Well Depth: ?u ►9 ft Static Water Level: 70 �Et Height of Water Column:56� 3a ft Well Locked: Construction: Data Sheet Review: Date; �d0.�� By. 'NO / Flushmount ) eel/Stainless Steel) Multi Factor*: 1163 [*(Radius/12)2 x 3.14 x 7.18) Casing Volume: /q • % gallons. Cal. 3 Volumes: 'y' gallons 91 �- Pump Intake: ,� ft Purge Information Date Purged: t / 20 / Start: 095t� Finish: NC )Purge Rate:J� MG`ML Ii Purging Method: Rr 5io—k,L et_, 0 Total Volume Purged: 6750 (gallonsAOL) Sampling Information Date Collected:_/eYi / oil Time Collected: If%T� a /pm) Sampling Equipment Used:-risw�Gc ?Lmp Instrument ID: hp(W VC407, M, Vb7ftd Bottle Type Preservatipn Analysis Required MNA Field Measurements/Observations Sample Temp (aC): I . pI Time: I 0 q''5 Turbidity (ntu): Time: o ti J� Digs Oxy (mg/L): C)r a- Time: Fe 2+ mg/L: '! • S Time: Specific Cond. (uS): Qri- Time:. Res. Cl (mg/L)/(µg/L): Time:. Sample pH (s.u.): (oa 7 Time: Odor: Eou, Time: ReDox (mV): % I •Jam' Time: Appearance: 000f . Time: ReDox (EH value):YSI ProPlus +200mV 1a$ 6 Other: Time: General/Weather Observations: (.A<<eC'I-lor" me -r., toQ0 Temp. 7a (7) Sampler Signature Stabilization Test Time Purged Temp. CC) Digs Oxy. (mg/L) Spec. PH (s.u.) ReDox (mV) Turbidity (ntu) Volume removed (gallons/O/ Water level (ft) Other (US) 01 i .7 g5 (6.1 �-54 D. r . 7 7.9a c©0 i . c r t 906 .•1 O.t ; Pas 7-ga Dao 101 ©, 90 6- -0• , t 375 7 gD bias Irrl o.5-t. , 1 1 - 0, b o,l za�= q5colNi.Sot Document Name: Document Issued: March 8,.2019 arc eeAtt��lyficaf Field ' Data Sheet Pagea-of X Doc unient Number: Issueing. Authority; f F CAR-FLD-001.rev.R3 Pace Huntersville Quality Office. % Client: 13� I �UCYDMIpe n, Location; ..A6I11cf NC. Project: styncorebe Co,61a LF ao w Well ID: mw-at- 94 Reviewed Date and By Stabilization Test' tlrell Diameter Multiplicatiort Factor"' 1 0.0403 1.2 0.0918 1.625 0.1030 2 0.1630 3 0.3670 4 0.6530 6 1.4680 3 2.6100 Time Purged Temp. o (C) Diss Oxy. (mg/L) Spec. Cord. us) (us)' pH (s.u.) ReDox (my) Turbidity (ntu) Volume RemovedWater (gallons Is circle e ) level () Other Inn Moj 0.3 90a G,7 -'70- 0,1 5'a5' 7A50� o3S -7.0 0.a 0;) l -73. ® a I 7, s a t7g0 1(o-9 O,a 90P -71.7 7S 7. Document Name: Field data Sheet Page: 10 " acer D80%P? - Issuing Authority: Pace H Document Number: F-CAR-FLD-001-rev.02 Office 27,2018 Name and Affiliation CIr)Jr-a LF A"--'p Ce held Data Sheet Review: Name and Affiliation (Inspector): �— Well Infformaation WellID: AVIV t / d c Well Diameter: Total Well Depth:ft Static Water Level:_ — C ft Height of Water Column: 6')r k Well Locked: Date: 0tt-Z9'Z� / NO) Construction: /Steel/Stainless Steel) Multi Factor*: j 161 [*(Radius/12)2 6IW ?81 Casing Volume D, S 6 011- gallons Cal.3 Volumes: � X.' k20 b t gallons Pump Intake: S• D ft By: �92 Purge Irdormati®n J dL V-/ 2/ 'b 6`l" purge �S�" r,..,.� Date Purged: � / +15 / Start : I3J Finish: � g //�� 5 Purging Method: At-A(0o1'-.c_ !✓ } Total Volume Purged: } S 0 (gallons/ s�us1' J /G V p Samyling hdonnation Date Collected: 6 / i4v --I Time Collected: 6 N "� (an& Sampling Equipment Used: 91 9 d 04" ®v^i Instrument ID: !7s r `F ``l 4 k/ .')- ;)' Bottle'Type Paeservation Analysis Required Mtj rc/o✓S n�tr✓ Field MeasuremaentS/Observations Sample Temp (C): 1' , O Time: / F1' Turbidity (ntu): • 0? Time: (. " Time: Dins Oxy (mg/L): `� 6 �s Fe 2+ m L: 0 g/ Time: - Specific Ccmd. (uS): A I b • 1 Time: / 6 `P` Res. Cl (mg/L)/(µg/L): Sample pH (s.u.): 7, 39 Time: NPr Odor: 3Ltt 97 0,1 Time: ReDox (mV): -- T me:J Appearance:C T me l 6� ReDox (EH Value):YSI PTOPIlls+200mV !ov . b Other: GeneraJ/Weathes Observations: 0 u c caf` y Temp. Wind s'ry (mph) sunn clou /rainy) CF) Sampler Signature:/ ✓�! r� Date: z/ SIA VddfLCLAUll 8 CDi Time Temp. Diss Oxy. Spec. Cond. pH (s.u.) ReDox Volume TurbidityWater removed Other Purged Cq (mg/L) (US) (mV) (ntu) (gsllons/mis) leyel(ft) ,fb . _,Y GIS�E� lso a,�,; z.2 J az. f S�`5 �S•� -779• of al h• I �, F � -�iJ• /`f.� : 3 DDJ Div -» b !� ) �r� D > Document Name: Document Issued: November 27, 2018 Field Data sheet pagd--Of �- Document Number: Issuemg Authority: F-CAR-PLD-001sev.02 Pace Huntersville Quality Office Client: 6 L 4 Location; 8uw("M& LLa,Fp Ge= Project: I(L.0 L--� Well ID: Reviewed Date and By: ZG Z( ty5 Stabilization Test 6sf"~11 �+2s7rn�bar "a1ra1?'i�a+,ix3n�`a�^car` 1.2 625 0-16 0 4 d= 1.4 LT 5; 2-6100 Time Purged 15 Temp. (°C) DissOxy. (mg/L) .Spec. Cond: (US)' pH �s.u.) - ReDox (mV) - Turbidity (ntu) VolumeRemoved" (gallon rnl) cycle one Water level O 14A�,- ' Other 6 19, 1 f4,13,? GT6 i;ro 13 '`l GftVirl�,�'ItG'aTl I Date Issued: November Docume ment Na: Field dV, 2011ata Sheet I Lt Document Number: F-CAR-FLD-001-rev.02 Name and Affiliation (Sampler(s): /' ,11 rf 9 S a Name and Affiliation (Inspector):- _ Well information Office CLo 3ed LF �' (✓ J Data Sheet Review: Date: 0q -Z g+21 By: Y' S Well ID: (ny } Well Locked: Q5S / NO) 11 Well Diameter: Construction St 1 St inl St 1 Total Well Depth: �7, I It Static Water Level: % 7 I It. Height of Water Column: �' ft V / ee / a ess ee ) Multi Factor":,_43— r(Radius/12)2 x 3.14 x 7.491 Casing Volume: 0, 0 3 X ( gallons Ca1.3 Volumes: - D'o,')e gallons Pump Intake: ft Purge Information Date Purged: —t-- j Start : <: Finish: Purge Rate: Purging Method: Total Volume Purged: —" (gallons/mis) Sampling Information Date Collected: `{ / d2l a ( Time Collected: / / 0 (a Pm Sampling Equipment Used: Ins�ument ID: Bottle Type Preservation Analysis Required (n/1✓rFi �!/-,✓ i F/� °- v,�t e fa J9lb/�0/r Field_ Measurements/Observations Sample TempA Diss Oxy (mg Specific Cond Sample pH (s ReDox (mV) ReDox (EH value):YSI ProPlus +20i Ceneral/Weather Observations: NO 1AM1l1 PA/ — Sampler Signature:( Stabilization Test Time: Turbidity (ntu): Time: Fe 2+ mg/L:_ Time: Res. CI (me/Lb Time: Time: _ Odor: Time: —Appearance: Other: Time: Innyl/cloudy/rainy) Temp. Bo ff) Windy"� (mph) �n�rP. CF - x1 - t- r Time Purged Temp. (°C) D ss Oxy. (mg/L) Spec. Cond.PH (s.u.) ReDox (mV) Turbidity (ntu) Volume (gallons/nds) Water level (it) Other ZeAnalyficalo PACE ANALYTICAL SERVICES, LLC 106 Vantage Point Drive • West Columbia, SC 29172 Telephone No.803-791-9700 Fax No. 803-791-9111 www.pacelabs.com Number 11,911 Client Report to Contact Telephone No. / E-mail Quote No. Address Sampler's Signature _ X' - -- Analysis (Attach list d more space is needed) Page o/ City State Zip Code - - - :' - - Lot #Bar Code (lab use only) Printed Name Project Name Project No. P.O. No. A ae �E Matrix No of Containers by Preservative Type Sample ID /Description (Contatners for each sample maybe wintined on one line.) Collection Date(s) cofiew n pine (Military) g a N S g o 2 c LL Remarks l Cooler LD. Vx Tam Around Tame Required(Pricrlabapprovalrequired farexpedded TAT.) ❑ Standard ^_. Rush(SpecW) Sample Disposal D Return to Client G Disposalby Lab Possible Hazard Identification ❑ Non -Hazard ❑ Flammable ❑ Skin Irritant Cr Poison ❑ Unknown QC Requirements (Specify) 1. Relinquished by Date Time 1. Received by -' __. Date Time 2. Relinquished by Date Time 2. Received by Date Time 3. Relinquished by Date Time 3. Received by Date Time 4. Relinquished by Date Time 4. Laboratory received by Date Time Note: All samples are retained for four weeksfrom receipt unless other arrangements are made. LAB USE ONLY Rece ed on ice (C rote) Yes No !ce Pack Receipt Temp. 'C Temp Blank i Y ❑ N DISTRIBUTION: WHITE & YELLOW -Return to laboratory with Sample(&); PINK-Field/Chent Copy Document Number: ME003N2-01 �B/47�7fyrr'al.,. Document Name: Field data Sheet Document Number: F-CAR-FLD-001-rev.02 Page: 1 of i ig AuNority. Pace Auntersvffle Quality Office Dint L. Z Field Data Sheet Name and Affiliation (Sampler(s): /' e' S 1017 EIdDa Sheet ReviewName and Affiliation (Inspector): p I �$1 Well Infformation We4� 50- I WellLec-ked----( PcFO) Well Diameter: � Total Well Depth: ft Static Water Level: ft. Height of Water Column: f ft Furge Imiormation Date Purged.. Construc?iex—EPvEf teeffStainlessSteel) Multi Factor*- r(Radius/12)2 x 3.14 x 7.491 Casing Volume: gallons Cal. 3 Volumes: �— gallons Pump Intake: ft Finish: Purge Rate: 0 Purging Methc:d-. - -- -Total Volume Pux'ged eal ans/mis) Sam�lan� 3rvfcrmation �u Date Collected: N / �?/ ri Time Collected: (�/P m) �y d Sampling Equipment Used: G !L 176 Instrument ID: `Yl '� O- ( � � ? Bottle Type Reservation Analysis Required ) �Lsr , , U NA10s /yd, lI d/ L L' Field Measurements/Observations 0% 1 Sample Temp (°C):Y i 6 `l Ti me: 4` Turbidity ntu : / F , I I ( . ) Time: Diss Oxy (mg/L): g'' > Time: ai 4- Fe 2+ mg/L: Specific Cond. (uS): 6 0• Time: ° Res. Cl Sample pH (s.u.): ? Time: 4 Odor: Nv -1L Time: �5 _ __ ReDox (mV): _ '�- � ' s Time: 9 FV Appearance: Q-k4 . Time: ReDox (EH value):YSI ProPlus +200mi d C /� e-q, , Other: 4ig2.61 General/Weather Observations: — u y cloudy/rainy) Temp. I' CF) Wind b --(mph) Sampler Signature p ('��— Date: $IdlYdBfl+aYLYUYI Time Purged_ AG56 Temp. . ('C) Diss Ox . Y (mg/L) Spec Cond. (US) ReDox pH (s.u.) (mV) volume Turbidity Water (ntu) removed level (ft) Other (galions/mis) Document Name: Field data Sheet Document Number: F-CAR-FLD-001-rev.02 Date ]ssued: November 27 12018 Page: 1 of 1 �g Autfioxit .Pace Huntersville Quality Office AL/ - Name and Affiliation (Sampler(s): hl>1 f'J2 Name and Affiliation (Inspector):- _ Well information Well Locked: Well Diameter: ,..,,e,,Cpnsmction: ( Total Well Depth: ,tt //' Multi Factor*:_ Static Water Level: f . Casing Volume: Height of Water Column: ft Cal. 3 Volumes: Pump Intake:_ Purge Irif rmalawr / . Date Purged:._/ / Fin Field Data Sheet Review: Date: 0'k,` `81,),( By: YES / NO) C/Steel/Stainless Steel) r(Radius/12)2 x 3.14 x 7.491 gallons gallons ft h: Purge Rate: Purging Method 142/( Total Volume (gallons/mis) Sampling Information Date Collected: 4 /Lyi II Time Collected: o &pm) Sampling Equipment Used: Gs e7r Instrument ID: ys ll 0 G w/ d r SottleType Preservation Analysis Required Field Measureneents/Observations a C . look � Turbidity ntu. T . 7 2 Time: / 0 R � Sample Temp (C): � `L_Time: Y ( . ) Diss Oxy (mg/L): Time: I' A O Fe 2+ mg/L.—Time:, Specific Cond. (uS): T . 5 Time: I 0 h ° Res. CI (mg/L)/(µg/L): Sample pH (s.u.): x l `� Time: r J 1 Odor: nyo „ c Time /V X ...._.._. _. ReDox(mV): ��7.6 Time: i JI`1i Appearance: C y.2.� rs� Tune: l 0 y. o ReDox (EH value):YSI ProPInS +200n V Z r g,1 Other: --�— Timer General/Weather Observations: 'Vj unn /cloudy/rainy) Temp. (°F) GVnda-r' (mph) Sampler Signature: cy/` �'� Date: - } Z '' JLa VaxxGi8xiulS Time Purged acsL Temp. CC) Diss Oxy. (mg/L) Spec. Cond. (US) pH (s.u.) ReDox (mV) Turbidity lume Water remove Other (nur) (gallons/cols) el (ft) (' Document Name: Field data Sheet Dacunent Number: F-CAR-FLD-001-rev.02 2018 l of office UL L Client: t L' Location: 05y r e Name and Affiliation (Sampler(s): Name and Affiliation (Inspector):_ Well Infforsmation Wrff,ff: Well Diameter: Total Well Depth: t t Static Water Level: Height of Water Column: \ It puree lnformati®n Date Purged: Well Locked: Construction: Multi Factor*: a� Project#:�`" CLofe.A 6� Sl✓ � T ta Sheet Review: 9 �1a3�a1 By. ( YES / NO) 'VC/Steel/Stainless Steel) r(Radius/12)2 x 3.14 x 7.481 Casing Volume: gal oun t r,A LF ) Cal, 3 Volumes: gallons Pump Intake: ft F n sh: Purge Rate: Purging Method:. }' Total Volume Purged: Sampling Information O Date Collected:— / �7/' / Time Collected: Z4P � � m) Sampling Equipment Used: Gxt,q 6 Instrument ID: ,l x re Bottle Type /c 3v�� s Preservation ffA—) . �I- Analysis Required A&I,11 //d FieldMeasnrelments/Observations �/ Sample Temp (C): Time: 160 Turbidity (nta): ` iz ^ ' T me:A D l Diss Oxy (mg/L): % �f Time: _ I a.5 Fe 2+ mg/L: Time: Specific Cond. (uS): Time: 0lo Res. CI Sample pH (s.u.): �r �, Time: i 3 a Odor: N-s --t Time: 3 - _o � ReDox (mV): �6 � 3 Tim) Appearance: C e �,¢ 2 r Time: I ° 6e: ReDox (EH value):YSI PtnPlus +200mV a Ltt. Other: CeneraVWea$herObservations 5v,1� S �✓�ae — (sunny/cloudy/rainy) Temp. �? ("F) Wind U `a (mph) Date:r Sampler Signature: oeuvaaaenu Time Purged Temp. ( q D ss Ox . (mg/L) Spec S� (US), pH (s.u.) ReDox (mV) Turbidity VolumeConeWater (nta) removed (gallons/mis) level (ft) Other 0 uet- Date Issued: November 27, 2018Page: Document Name: Field data Sheet 1 of ", RCEdy1fO1!(' Issuing Authority; Pace Huntersville Quabty Document Number: F-CAR-FLD-001-xev.02 Office Client b L / Location: u/oc: Name and Affiliation (Sampler(s): it �d9/9 I Name and Affiliation (Inspector):_ Well information WeH4P- 5w -' Well Locked: Well Diameter: Total Well Depth: tiC I µ ft Static Water Level: ft Height of Water Column: ft Date Purging Sampling Information Construction: Multi Factor*: Casing Volume: Cal. 3 Volumes: Data Sheet Review: Date: cAnn )x ( YES / NO) �C/Steel/Stainless Steel) r(Radius/12)2 x 3.14 x 7.481 gallons gallons Pump Intake: ft _ Finish: Purge Rate: rf Vel �utge l' (gallons/mis) Date Collected: Time Collected: / 4 Sampling Equipment Used: D rt 4 h Instrument ID: `7-K1 S` t, L 4�, Bottle Type Preservation Analysis Required )3 H C V9 u Field Measurements/Observations Sample Temp (°C): /J�, Z Time:0(-1— Turbidity (nm): . S' 1 Time: Diss Oxy (mg/L): i / Time: Fe 2+ mg/L —lSme: ---_._ Specific Cond. (uS): t Time: Res. Cl (mg/L)/(µg/L): � lime: Sample pH (s.u.): F / Time: Odor: N0 oa o 2 Time: ReDox (mV): ' -�7 4 Time: Appearance: Ng zy Time: ReDox (EH value):YSI ProPlus +200mV S `f Other: -'-Time: General/Weather Observations: DyCiCAs� 14,114M Esimky/(lo 4y`/rainy) Temp. Wind-9- (mph) Sampler Signature: . Date: Stabilization Test Time Purged Temp. (°C) Diss Oxy. (mg/L) Spec. Con(uS) d. pH (s.u.)' ReDox (mV) Turbidity (ntu) em�d (gallons/mls) Water level (ft) Other �-- -�>.l- off Dale Issued: November 27, 2018 Document Name: FieIddate Sheet Page: lof_( EfF1&i43rePL`Hrr Issuing AatholnT Pace Huntersville Quality Document Numbex: F-CAR-FLD-DDl-xev.02 Office Field Data Sheet #: L1916 f? �a Name and Affiliation (Sampler(s): M I / aaSheet ReviewName and Affiliation (Inspector):. � By. LD : I ��` Well InffornmtioA Well ID: S W WellLocked: (YES / NO) Well Di' ter: Construction: VC/St eel/9ta mess Steel) TotalWell'Dep _ At Multi Factor' : r3�1 *2Ra//dies/122 x 3.14 x 7.491 [ ✓� Static Water Level: ( 8'r / Casing Volume: gallons Height of Water Column: ft Cal. 3 Volumesr gallons 1 Pump Intake: ft Fume Inf n Date Purged:._/_ tart: _ Finish:�t}urge�a�t��/ �F Purging Method. Total Volume Purged: /mis) D uh Sampling Wormation / Date Collected: / / '` / Time Collected: /l'0+— �a/pm) �� �CF26 Sampling Equipment Used: G 2 9 n Instrument ID: �l S Bottle Type Preservation Analysis Required f Pia,-xt l',1� 3 v, Field Measurements/®bservat ons 3 ( 3 Sample Temp (°C): - ( I O Time: 0 d . Turbidity (ntu): T me: Dies Oxy (mg/ L): 7' l' e Time: I /J + Fe 2+ mgJL: T me: Specific Cond. (nS): y Time: 110 v Res. 0 (mg/LY(µg/L): Time: Sample pH (s.u.): •` / Time: �/ J Odor: Time: _ ReDox(mV): �4. ° Time: //D` Appearance ReDox (EH value):YSI PmPlus +200mV . �' 9• 0 Other: 1me: C eneral/Weathea Observations: O t/� — r _fsCnny�c ou y/rainy) Temp.7P(OF) Wind-0 G (mph) Sampler Signature: ` 4 v� Date: stamuzanon Time Purged iesc Temp. D ss Oxy. (°C) (mg/L) c Spec. (us) ReDox TurbidityVolume Water pH (s.u.) removed Other (mV) (Tit(gallons/mis) level(ft) ll l D S. % 7 14- APPENDIX B LABORATORY ANALYTICAL DATA - PACE ANALYTICAL SERVICES, LLC. 0 aceAnalytical Report of Analysis Bunnell-Lammons Engineering, Inc. 6004 Ponders Court Greenville, SC 29615 Attention: Andy Alexander Project Name: Closed Buncombe County Landfill Wells Project Number: J21-14175-05 Lot Number:WD30017 Date Completed:05/16/2021 N N NO � � J 05/19/2021 8:36 AM Approved and released by: Project Manager II: Lucas Odom pCCgF� 24r�A SOA ANSI National Accreditation Board A C C R E D I T E D TESTING LABORATORY The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 1 of 175 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative Bunnell-Lammons Engineering, Inc. Lot Number: WD30017 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved The NELAC Institute (TNI) standards, the Pace Analytical Services, LLC ("Pace") Laboratory Quality Manual, standard operating procedures (SOPS), and Pace policies. Any exceptions to the TNI standards, the Laboratory Quality Manual, SOPs or policies are qualified on the results page or discussed below. If you have any questions regarding this report please contact the Pace Project Manager listed on the cover page. Inorganic Non -Metals The following samples were diluted due to the nature of the sample matrix for NO3 analysis: WD30017- 015, WD30017-022. The LOQ has been elevated to reflect the dilution. Reanalysis of the following sample was performed outside of the analytical holding time for NO3 analysis: WD30017-010. This sample was reanalyzed due to matrix interference during initial analysis. The BOD method blank result was higher than the method -required limit of 0.20mg/L. The seed correction factor was below the method range. No corrective action is required as the BOD calculation adjusts for variances in the SCF. Associated samples have been qualified witha "4" and 7" respectively. VOCs by GC/MS The laboratory control sample (LCS) for analytical batch 92125 exceeded acceptance criteria for Acetone. This analytes is biased high but not detected in the samples affected. In addition, this batch recovered trans-1,4-Dichloro-2-butene below method criteria. An LOQ standard was analyzed, and the target analyte was detected. Since the associated samples are non -detect, no corrective action was taken. Associated samples have been qualified with an 'U'. The laboratory control sample (LCS) for analytical batch 92172 exceeded acceptance criteria for Acetone, 2-Butanone, and 2-Hexanone. These analytes are biased high but not detected in the samples affected. Associated samples have been qualified with an 'U'. The method blank associated with batch 92056 yielded "J" value detections for Chloroform and Tetrachloroethene. No corrective action is required as these are estimated values recovered below the LOQ. Associated detections have been qualified with a "B". Subcontracted Analysis The analysis for VFA, MEE, CO2, and H have been performed by Pace Gulf Coast. This data has been ammended to this report starting on page 154. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 whw.pacelabs.com Page 2 of 175 PACE ANALYTICAL SERVICES, LLC Sample Summary Bunnell-Lammons Engineering, Inc. Lot Number: WD30017 Sample Number Sample ID Matrix Date Sampled Date Received 001 DPL-1 Aqueous 04/28/20211515 04/29/2021 002 MW-3 Aqueous 04/28/20211430 04/29/2021 003 MW-4A Aqueous 04/28/20211455 04/29/2021 004 MW-5 Aqueous 04/28/20211355 04/29/2021 005 MW-6-192 Aqueous 04/28/20211615 04/29/2021 006 MW-7 Aqueous 04/28/20211700 04/29/2021 007 MW-15 Aqueous 04/28/20211305 04/29/2021 008 Trip Blank Aqueous 04/28/2021 009 MW-2 Aqueous 04/29/20211000 04/30/2021 010 MW-6 Aqueous 04/29/20211205 04/30/2021 011 MW-4 Aqueous 04/29/20211410 04/30/2021 012 MW-B Aqueous 04/29/20211630 04/30/2021 013 MW-12-25 Aqueous 04/29/20210930 04/30/2021 014 MW-13-35 Aqueous 04/29/20211030 04/30/2021 015 MW-13-132 Aqueous 04/29/20211355 04/30/2021 016 MW-17-60 Aqueous 04/29/20211455 04/30/2021 017 MW-17-137 Aqueous 04/29/20211355 04/30/2021 018 MW-17-310 Aqueous 04/29/20211310 04/30/2021 019 MW-18-78 Aqueous 04/29/20211010 04/30/2021 020 MW-19-75 Aqueous 04/29/20211145 04/30/2021 021 MW-19-110 Aqueous 04/29/20211310 04/30/2021 022 MW-21-21 Aqueous 04/29/20211220 04/30/2021 023 MW-21-94 Aqueous 04/29/20211045 04/30/2021 024 MW-24-160 Aqueous 04/29/20211645 04/30/2021 025 Field Blank Aqueous 04/29/2021 1300 04/30/2021 026 Trip Blank Aqueous 04/29/2021 04/30/2021 027 Trip Blank Aqueous 04/29/2021 04/30/2021 (27 samples) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 3 of 175 PACE ANALYTICAL SERVICES, LLC Detection Summary Bunnell-Lammons Engineering, Inc. Lot Number: WD30017 Sample Sample ID Matrix Parameter Method Result Q Units Page 001 DPL-1 Aqueous Acetone 8260D 11 J ug/L 13 001 DPL-1 Aqueous Antimony 6020B 0.80 J ug/L 14 001 DPL-1 Aqueous Barium 6020B 85 ug/L 14 001 DPL-1 Aqueous Chromium 6020B 55 ug/L 14 001 DPL-1 Aqueous Cobalt 6020B 4.0 J ug/L 14 001 DPL-1 Aqueous Copper 6020B 5.6 ug/L 14 001 DPL-1 Aqueous Lead 6020B 2.1 ug/L 14 001 DPL-1 Aqueous Nickel 6020B 53 ug/L 14 001 DPL-1 Aqueous Zinc 6020B 14 ug/L 15 002 MW-3 Aqueous 1,4-Dioxane 8260D (SIM) 95 ug/L 16 002 MW-3 Aqueous Benzene 8260D 1.6 ug/L 16 002 MW-3 Aqueous Chlorobenzene 8260D 4.4 ug/L 16 002 MW-3 Aqueous Chloroethane 8260D 3.2 ug/L 16 002 MW-3 Aqueous 1,2-Dichlorobenzene 8260D 0.83 J ug/L 16 002 MW-3 Aqueous 1,4-Dichlorobenzene 8260D 7.2 ug/L 16 002 MW-3 Aqueous 1,1-Dichloroethane 8260D 1.3 ug/L 16 002 MW-3 Aqueous cis- 1,2-Dichloroethene 8260D 0.65 J ug/L 16 002 MW-3 Aqueous Vinyl chloride 8260D 0.72 J ug/L 17 002 MW-3 Aqueous Xylenes (total) 8260D 0.89 J ug/L 17 002 MW-3 Aqueous Barium 6020B 240 ug/L 17 002 MW-3 Aqueous Cadmium 6020B 0.19 J ug/L 17 002 MW-3 Aqueous Cobalt 6020B 15 ug/L 17 002 MW-3 Aqueous Nickel 6020B 32 ug/L 17 002 MW-3 Aqueous Selenium 6020B 1.9 J ug/L 18 002 MW-3 Aqueous Zinc 6020B 25 ug/L 18 003 MW-4A Aqueous 1,4-Dioxane 8260D (SIM) 31 ug/L 19 003 MW-4A Aqueous Benzene 8260D 5.6 ug/L 19 003 MW-4A Aqueous Chlorobenzene 8260D 28 ug/L 19 003 MW-4A Aqueous 1,2-Dichlorobenzene 8260D 4.4 ug/L 19 003 MW-4A Aqueous 1,4-Dichlorobenzene 8260D 25 ug/L 19 003 MW-4A Aqueous trans- 1,2-Dichloroethene 8260D 0.44 J ug/L 19 003 MW-4A Aqueous Ethylbenzene 8260D 6.8 ug/L 20 003 MW-4A Aqueous 4-Methyl-2-pentanone 8260D 4.9 J ug/L 20 003 MW-4A Aqueous Toluene 8260D 2.7 ug/L 20 003 MW-4A Aqueous Vinyl chloride 8260D 1.0 ug/L 20 003 MW-4A Aqueous Xylenes (total) 8260D 12 ug/L 20 003 MW-4A Aqueous Barium 6020B 670 ug/L 20 003 MW-4A Aqueous Cadmium 6020B 0.18 J ug/L 20 003 MW-4A Aqueous Cobalt 6020B 48 ug/L 20 003 MW-4A Aqueous Copper 6020B 4.0 J ug/L 20 003 MW-4A Aqueous Nickel 6020B 9.7 ug/L 20 003 MW-4A Aqueous Zinc 6020B 2.7 J ug/L 21 004 MW-5 Aqueous 1,4-Dioxane 8260D (SIM) 73 ug/L 22 004 MW-5 Aqueous Benzene 8260D 0.86 J ug/L 22 004 MW-5 Aqueous Chlorobenzene 8260D 8.7 ug/L 22 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 4 of 175 Detection Summary (Continued) Lot Number: WD30017 Sample Sample ID Matrix Parameter Method Result Q Units Page 004 MW-5 Aqueous Chloroethane 8260D 1.0 J ug/L 22 004 MW-5 Aqueous 1,4-Dichlorobenzene 8260D 4.8 ug/L 22 004 MW-5 Aqueous 1,1-Dichloroethane 8260D 0.51 J ug/L 22 004 MW-5 Aqueous Barium 6020B 170 ug/L 23 004 MW-5 Aqueous Cobalt 6020B 11 ug/L 23 004 MW-5 Aqueous Nickel 6020B 19 ug/L 23 004 MW-5 Aqueous Selenium 6020B 2.1 J ug/L 24 005 MW-6-192 Aqueous 1,4-Dioxane 8260D (SIM) 5.6 ug/L 25 005 MW-6-192 Aqueous Chlorobenzene 8260D 0.96 J ug/L 25 005 MW-6-192 Aqueous Chloroethane 8260D 0.65 J ug/L 25 005 MW-6-192 Aqueous 1,4-Dichlorobenzene 8260D 0.43 J ug/L 25 005 MW-6-192 Aqueous 1,1-Dichloroethane 8260D 0.69 J ug/L 25 005 MW-6-192 Aqueous Barium 6020B 61 ug/L 26 005 MW-6-192 Aqueous Nickel 6020B 1.5 J ug/L 26 006 MW-7 Aqueous Benzene 8260D 2.4 ug/L 28 006 MW-7 Aqueous Chlorobenzene 8260D 13 ug/L 28 006 MW-7 Aqueous Chloroethane 8260D 3.4 ug/L 28 006 MW-7 Aqueous 1,4-Dichlorobenzene 8260D 5.8 ug/L 28 006 MW-7 Aqueous 1,1-Dichloroethane 8260D 2.1 ug/L 28 006 MW-7 Aqueous cis- 1,2-Dichloroethene 8260D 20 ug/L 28 006 MW-7 Aqueous Trichloroethene 8260D 0.60 J ug/L 29 006 MW-7 Aqueous Xylenes (total) 8260D 0.54 J ug/L 29 006 MW-7 Aqueous Barium 6020B 180 ug/L 29 006 MW-7 Aqueous Beryllium 6020B 0.20 J ug/L 29 006 MW-7 Aqueous Cadmium 6020B 0.14 J ug/L 29 006 MW-7 Aqueous Cobalt 6020B 200 ug/L 29 006 MW-7 Aqueous Copper 6020B 14 ug/L 29 006 MW-7 Aqueous Lead 6020B 0.45 J ug/L 29 006 MW-7 Aqueous Nickel 6020B 57 ug/L 29 006 MW-7 Aqueous Zinc 6020B 13 ug/L 29 007 MW-15 Aqueous Acetone 8260D 12 J ug/L 30 007 MW-15 Aqueous Barium 6020B 220 ug/L 31 007 MW-15 Aqueous Chromium 6020B 12 ug/L 31 007 MW-15 Aqueous Lead 6020B 1.2 ug/L 31 009 MW-2 Aqueous Alkalinity @ pH 4.5 su SM 232013- 64 mg CaCO3/L 32 009 MW-2 Aqueous Chloride 9056A 2.4 mg/L 32 009 MW-2 Aqueous Nitrate - N 9056A 0.027 mg/L 32 009 MW-2 Aqueous Sulfate 9056A 3.2 mg/L 32 009 MW-2 Aqueous Sulfide SM 4500-S2 F- 1.2 mg/L 32 009 MW-2 Aqueous TOC SM 5310C- 11 mg/L 32 009 MW-2 Aqueous Antimony 6020B 1.0 J ug/L 34 009 MW-2 Aqueous Barium 6020B 25 ug/L 34 009 MW-2 Aqueous Chromium 6020B 2.2 J ug/L 34 009 MW-2 Aqueous Copper 6020B 2.7 J ug/L 34 009 MW-2 Aqueous Lead 6020B 0.77 J ug/L 34 009 MW-2 Aqueous Nickel 6020B 7.5 ug/L 34 009 MW-2 Aqueous Zinc 6020B 8.9 J ug/L 34 010 MW-6 Aqueous Alkalinity @ pH 4.5 su SM 2320B- 570 mg CaCO3/L 35 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 5 of 175 Detection Summary (Continued) Lot Number: WD30017 Sample Sample ID Matrix Parameter Method Result Q Units Page 010 MW-6 Aqueous BOD, 5 day SM 521013- 6.6 47 mg/L 35 010 MW-6 Aqueous Chloride 9056A 160 mg/L 35 010 MW-6 Aqueous COD SM 5220D- 42 mg/L 35 010 MW-6 Aqueous Sulfate 9056A 1.1 mg/L 35 010 MW-6 Aqueous TOC SM 5310C- 15 mg/L 35 010 MW-6 Aqueous 1,4-Dioxane 8260D (SIM) 33 ug/L 35 010 MW-6 Aqueous Benzene 8260D 1.3 ug/L 35 010 MW-6 Aqueous Carbon disulfide 8260D 4.2 ug/L 36 010 MW-6 Aqueous Chlorobenzene 8260D 7.5 ug/L 36 010 MW-6 Aqueous Chloroethane 8260D 3.5 ug/L 36 010 MW-6 Aqueous 1,4-Dichlorobenzene 8260D 2.6 ug/L 36 010 MW-6 Aqueous 1,1-Dichloroethane 8260D 1.8 ug/L 36 010 MW-6 Aqueous cis- 1,2-Dichloroethene 8260D 1.4 ug/L 36 010 MW-6 Aqueous Tetrachloroethene 8260D 0.87 BJ ug/L 36 010 MW-6 Aqueous Barium 6020B 1700 ug/L 37 010 MW-6 Aqueous Nickel 6020B 11 ug/L 37 010 MW-6 Aqueous Selenium 6020B 1.3 J ug/L 37 010 MW-6 Aqueous Zinc 6020B 6.1 J ug/L 37 011 MW-4 Aqueous Alkalinity @ pH 4.5 su SM 232013- 450 mg CaCO3/1- 38 011 MW-4 Aqueous Chloride 9056A 0.32 J mg/L 38 011 MW-4 Aqueous COD SM 5220D- 20 mg/L 38 011 MW-4 Aqueous TOC SM 5310C- 6.3 mg/L 38 011 MW-4 Aqueous 1,4-Dioxane 8260D (SIM) 24 ug/L 38 011 MW-4 Aqueous Benzene 8260D 0.86 J ug/L 38 011 MW-4 Aqueous Chlorobenzene 8260D 6.0 ug/L 39 011 MW-4 Aqueous Chloroethane 8260D 2.0 ug/L 39 011 MW-4 Aqueous 1,2-Dichlorobenzene 8260D 0.73 J ug/L 39 011 MW-4 Aqueous 1,4-Dichlorobenzene 8260D 9.5 ug/L 39 011 MW-4 Aqueous 1,1-Dichloroethane 8260D 7.2 ug/L 39 011 MW-4 Aqueous cis- 1,2-Dichloroethene 8260D 16 ug/L 39 011 MW-4 Aqueous Tetrachloroethene 8260D 1.2 B ug/L 39 011 MW-4 Aqueous Trichloroethene 8260D 0.82 J ug/L 39 011 MW-4 Aqueous Vinyl chloride 8260D 3.0 ug/L 39 011 MW-4 Aqueous Barium 6020B 630 ug/L 40 011 MW-4 Aqueous Cadmium 6020B 0.84 ug/L 40 011 MW-4 Aqueous Cobalt 6020B 76 ug/L 40 011 MW-4 Aqueous Nickel 6020B 93 ug/L 40 011 MW-4 Aqueous Zinc 6020B 17 ug/L 40 012 MW-B Aqueous 1,4-Dioxane 8260D (SIM) 22 ug/L 41 012 MW-B Aqueous Chloroethane 8260D 0.61 J ug/L 41 012 MW-B Aqueous 1,4-Dichlorobenzene 8260D 0.75 J ug/L 41 012 MW-B Aqueous cis- 1,2-Dichloroethene 8260D 4.7 ug/L 41 012 MW-B Aqueous Tetrachloroethene 8260D 0.68 BJ ug/L 42 012 MW-B Aqueous Vinyl chloride 8260D 2.3 ug/L 42 012 MW-B Aqueous Arsenic 6020B 1.4 J ug/L 42 012 MW-B Aqueous Barium 6020B 290 ug/L 42 013 MW-12-25 Aqueous cis-1,2-Dichloroethene 8260D 0.57 J ug/L 44 013 MW-12-25 Aqueous Tetrachloroethene 8260D 0.63 BJ ug/L 44 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 6 of 175 Detection Summary (Continued) Lot Number: WD30017 Sample Sample ID Matrix Parameter Method Result Q Units Page 013 MW-12-25 Aqueous Barium 6020B 58 ug/L 45 013 MW-12-25 Aqueous Copper 6020B 1.3 J ug/L 45 013 MW-12-25 Aqueous Nickel 6020B 15 ug/L 45 013 MW-12-25 Aqueous Zinc 6020B 9.1 J ug/L 45 014 MW-13-35 Aqueous Benzene 8260D 1.1 ug/L 46 014 MW-13-35 Aqueous Chlorobenzene 8260D 5.0 ug/L 46 014 MW-13-35 Aqueous 1,2-Dichlorobenzene 8260D 3.1 ug/L 46 014 MW-13-35 Aqueous 1,4-Dichlorobenzene 8260D 16 ug/L 46 014 MW-13-35 Aqueous cis-1,2-Dichloroethene 8260D 2.7 ug/L 46 014 MW-13-35 Aqueous Tetrachloroethene 8260D 0.66 BJ ug/L 46 014 MW-13-35 Aqueous Vinyl chloride 8260D 0.61 J ug/L 47 014 MW-13-35 Aqueous Barium 6020B 180 ug/L 47 014 MW-13-35 Aqueous Cobalt 6020B 1.3 J ug/L 47 014 MW-13-35 Aqueous Nickel 6020B 4.8 J ug/L 47 014 MW-13-35 Aqueous Zinc 6020B 8.0 J ug/L 47 015 MW-13-132 Aqueous Alkalinity @ pH 4.5 su SM 232013- 150 mg CaCO3/1- 48 015 MW-13-132 Aqueous Chloride 9056A 5.1 mg/L 48 015 MW-13-132 Aqueous Nitrate - N 9056A 0.028 J mg/L 48 015 MW-13-132 Aqueous Sulfate 9056A 7.8 mg/L 48 015 MW-13-132 Aqueous TOC SM 5310C- 1.1 mg/L 48 015 MW-13-132 Aqueous Benzene 8260D 1.0 ug/L 48 015 MW-13-132 Aqueous Carbon disulfide 8260D 2.7 ug/L 48 015 MW-13-132 Aqueous 1,4-Dichlorobenzene 8260D 0.58 J ug/L 49 015 MW-13-132 Aqueous cis- 1,2-Dichloroethene 8260D 2.6 ug/L 49 015 MW-13-132 Aqueous Tetrachloroethene 8260D 0.53 BJ ug/L 49 015 MW-13-132 Aqueous Vinyl chloride 8260D 0.91 J ug/L 49 015 MW-13-132 Aqueous Barium 6020B 41 ug/L 50 015 MW-13-132 Aqueous Nickel 6020B 2.2 J ug/L 50 015 MW-13-132 Aqueous Zinc 6020B 6.9 J ug/L 50 016 MW-17-60 Aqueous 1,4-Dioxane 8260D (SIM) 26 ug/L 51 016 MW-17-60 Aqueous 1,4-Dichlorobenzene 8260D 0.53 J ug/L 51 016 MW-17-60 Aqueous 1, 1 -Dichloroethane 8260D 1.1 ug/L 51 016 MW-17-60 Aqueous cis- 1,2-Dichloroethene 8260D 2.5 ug/L 51 016 MW-17-60 Aqueous Tetrachloroethene 8260D 0.54 BJ ug/L 52 016 MW-17-60 Aqueous Vinyl chloride 8260D 1.2 ug/L 52 016 MW-17-60 Aqueous Barium 6020B 24 ug/L 52 017 MW-17-137 Aqueous 1,4-Dioxane 8260D (SIM) 35 ug/L 54 017 MW-17-137 Aqueous Chloroethane 8260D 0.43 J ug/L 54 017 MW-17-137 Aqueous 1,4-Dichlorobenzene 8260D 0.68 J ug/L 54 017 MW-17-137 Aqueous 1, 1 -Dichloroethane 8260D 0.78 J ug/L 54 017 MW-17-137 Aqueous cis-1,2-Dichloroethene 8260D 0.61 J ug/L 54 017 MW-17-137 Aqueous Tetrachloroethene 8260D 0.51 BJ ug/L 55 017 MW-17-137 Aqueous Vinyl chloride 8260D 0.74 J ug/L 55 017 MW-17-137 Aqueous Xylenes (total) 8260D 0.46 J ug/L 55 017 MW-17-137 Aqueous Barium 6020B 24 ug/L 55 018 MW-17-310 Aqueous 2-Butanone (MEK) 8260D 3.4 J ug/L 57 018 MW-17-310 Aqueous Barium 6020B 3.3 J ug/L 58 018 MW-17-310 Aqueous Lead 6020B 0.31 J ug/L 58 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 7 of 175 Detection Summary (Continued) Lot Number: WD30017 Sample Sample ID Matrix Parameter Method Result Q Units Page 018 MW-17-310 Aqueous Zinc 6020B 3.1 J ug/L 58 019 MW-18-78 Aqueous Alkalinity @ pH 4.5 su SM 232013- 300 mg CaCO3/L 59 019 MW-18-78 Aqueous BOD, 5 day SM 5210B- 2.7 mg/L 59 019 MW-18-78 Aqueous Chloride 9056A 150 mg/L 59 019 MW-18-78 Aqueous COD SM 5220D- 33 mg/L 59 019 MW-18-78 Aqueous Sulfate 9056A 2.2 mg/L 59 019 MW-18-78 Aqueous Sulfide SM 4500-S2 F- 3.7 mg/L 59 019 MW-18-78 Aqueous TOC SM 5310C- 8.9 mg/L 59 019 MW-18-78 Aqueous 1,4-Dioxane 8260D (SIM) 53 ug/L 59 019 MW-18-78 Aqueous Benzene 8260D 0.53 J ug/L 59 019 MW-18-78 Aqueous Chlorobenzene 8260D 4.0 ug/L 60 019 MW-18-78 Aqueous Chloroethane 8260D 0.70 J ug/L 60 019 MW-18-78 Aqueous 1,4-Dichlorobenzene 8260D 3.1 ug/L 60 019 MW-18-78 Aqueous 1, 1 -Dichloroethane 8260D 0.98 J ug/L 60 019 MW-18-78 Aqueous cis-1,2-Dichloroethene 8260D 0.95 J ug/L 60 019 MW-18-78 Aqueous Vinyl chloride 8260D 0.83 J ug/L 60 019 MW-18-78 Aqueous Barium 6020B 75 ug/L 61 019 MW-18-78 Aqueous Nickel 6020B 7.2 ug/L 61 020 MW-19-75 Aqueous Alkalinity @ pH 4.5 su SM 232013- 410 mg CaCO3/1- 62 020 MW-19-75 Aqueous Chloride 9056A 150 mg/L 62 020 MW-19-75 Aqueous COD SM 5220D- 40 mg/L 62 020 MW-19-75 Aqueous Nitrate - N 9056A 0.012 J mg/L 62 020 MW-19-75 Aqueous Sulfate 9056A 17 mg/L 62 020 MW-19-75 Aqueous TOC SM 5310C- 12 mg/L 62 020 MW-19-75 Aqueous 1,4-Dioxane 8260D (SIM) 87 ug/L 62 020 MW-19-75 Aqueous Acetone 8260D 5.2 JL ug/L 62 020 MW-19-75 Aqueous Chlorobenzene 8260D 4.2 ug/L 63 020 MW-19-75 Aqueous 1,4-Dichlorobenzene 8260D 3.2 ug/L 63 020 MW-19-75 Aqueous 1, 1 -Dichloroethane 8260D 0.47 J ug/L 63 020 MW-19-75 Aqueous Barium 6020B 120 ug/L 64 020 MW-19-75 Aqueous Cobalt 6020B 3.4 J ug/L 64 020 MW-19-75 Aqueous Nickel 6020B 22 ug/L 64 020 MW-19-75 Aqueous Zinc 6020B 5.5 J ug/L 64 021 MW-19-110 Aqueous Alkalinity @ pH 4.5 su SM 232013- 170 mg CaCO3/1- 65 021 MW-19-110 Aqueous Chloride 9056A 41 mg/L 65 021 MW-19-110 Aqueous Sulfate 9056A 12 mg/L 65 021 MW-19-110 Aqueous TOC SM 5310C- 2.8 mg/L 65 021 MW-19-110 Aqueous 1,4-Dioxane 8260D (SIM) 35 ug/L 65 021 MW-19-110 Aqueous Chlorobenzene 8260D 0.78 J ug/L 66 021 MW-19-110 Aqueous Chloroethane 8260D 0.87 J ug/L 66 021 MW-19-110 Aqueous 1,4-Dichlorobenzene 8260D 0.76 J ug/L 66 021 MW-19-110 Aqueous cis- 1,2-Dichloroethene 8260D 0.93 J ug/L 66 021 MW-19-110 Aqueous Barium 6020B 11 ug/L 67 021 MW-19-110 Aqueous Nickel 6020B 4.1 J ug/L 67 021 MW-19-110 Aqueous Zinc 6020B 7.5 J ug/L 67 022 MW-21-21 Aqueous Alkalinity @ pH 4.5 su SM 232013- 770 mg CaCO3/L 68 022 MW-21-21 Aqueous BOD, 5 day SM 521013- 3.7 mg/L 68 022 MW-21-21 Aqueous Chloride 9056A 70 mg/L 68 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 8 of 175 Detection Summary (Continued) Lot Number: WD30017 Sample Sample ID Matrix Parameter Method Result Q Units Page 022 MW-21-21 Aqueous COD SM 5220D- 58 mg/L 68 022 MW-21-21 Aqueous Sulfate 9056A 23 mg/L 68 022 MW-21-21 Aqueous Sulfide SM 4500-S2 F- 1.5 mg/L 68 022 MW-21-21 Aqueous TOC SM 5310C- 15 mg/L 68 022 MW-21-21 Aqueous 1,4-Dioxane 8260D (SIM) 30 ug/L 68 022 MW-21-21 Aqueous Benzene 8260D 2.8 ug/L 68 022 MW-21-21 Aqueous Carbon disulfide 8260D 0.53 J ug/L 69 022 MW-21-21 Aqueous Chlorobenzene 8260D 32 ug/L 69 022 MW-21-21 Aqueous 1,2-Dichlorobenzene 8260D 4.0 ug/L 69 022 MW-21-21 Aqueous 1,4-Dichlorobenzene 8260D 14 ug/L 69 022 MW-21-21 Aqueous 1,1-Dichloroethane 8260D 2.8 ug/L 69 022 MW-21-21 Aqueous 1,2-Dichloroethane 8260D 0.43 J ug/L 69 022 MW-21-21 Aqueous cis- 1,2-Dichloroethene 8260D 5.8 ug/L 69 022 MW-21-21 Aqueous Toluene 8260D 0.66 J ug/L 69 022 MW-21-21 Aqueous Trichloroethene 8260D 0.51 J ug/L 69 022 MW-21-21 Aqueous Vinyl chloride 8260D 2.2 ug/L 69 022 MW-21-21 Aqueous Xylenes (total) 8260D 0.60 J ug/L 69 022 MW-21-21 Aqueous Barium 6020B 120 ug/L 70 022 MW-21-21 Aqueous Cobalt 6020B 12 ug/L 70 022 MW-21-21 Aqueous Nickel 6020B 4.6 J ug/L 70 022 MW-21-21 Aqueous Zinc 6020B 2.7 J ug/L 70 023 MW-21-94 Aqueous Alkalinity @ pH 4.5 su SM 2320B- 310 mg CaCO3/L 71 023 MW-21-94 Aqueous Chloride 9056A 98 mg/L 71 023 MW-21-94 Aqueous COD SM 5220D- 28 mg/L 71 023 MW-21-94 Aqueous Sulfate 9056A 3.3 mg/L 71 023 MW-21-94 Aqueous Sulfide SM 4500-S2 F- 2.6 mg/L 71 023 MW-21-94 Aqueous TOC SM 5310C- 7.3 mg/L 71 023 MW-21-94 Aqueous 1,4-Dioxane 8260D (SIM) 46 ug/L 71 023 MW-21-94 Aqueous Chlorobenzene 8260D 1.8 ug/L 72 023 MW-21-94 Aqueous Chloroethane 8260D 2.3 ug/L 72 023 MW-21-94 Aqueous 1,2-Dichlorobenzene 8260D 0.44 J ug/L 72 023 MW-21-94 Aqueous 1,4-Dichlorobenzene 8260D 2.8 ug/L 72 023 MW-21-94 Aqueous 1,1-Dichloroethane 8260D 1.2 ug/L 72 023 MW-21-94 Aqueous 1,2-Dichloroethane 8260D 0.42 J ug/L 72 023 MW-21-94 Aqueous cis- 1,2-Dichloroethene 8260D 2.9 ug/L 72 023 MW-21-94 Aqueous Vinyl chloride 8260D 1.2 ug/L 72 023 MW-21-94 Aqueous Barium 6020B 47 ug/L 73 023 MW-21-94 Aqueous Nickel 6020B 8.0 ug/L 73 024 MW-24-160 Aqueous Alkalinity @ pH 4.5 su SM 232013- 70 mg CaCO3/L 74 024 MW-24-160 Aqueous Chloride 9056A 6.5 mg/L 74 024 MW-24-160 Aqueous Sulfate 9056A 23 mg/L 74 024 MW-24-160 Aqueous Sulfide SM 4500-S2 F- 1.8 mg/L 74 024 MW-24-160 Aqueous TOC SM 5310C- 1.4 mg/L 74 024 MW-24-160 Aqueous Barium 6020B 27 ug/L 76 024 MW-24-160 Aqueous Copper 6020B 1.3 J ug/L 76 024 MW-24-160 Aqueous Lead 6020B 0.74 J ug/L 76 024 MW-24-160 Aqueous Nickel 6020B 1.6 J ug/L 76 024 MW-24-160 Aqueous Zinc 6020B 7.2 J ug/L 76 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 9 of 175 Detection Summary (Continued) Lot Number: WD30017 Sample Sample ID Matrix Parameter Method Result Q Units Page 025 Field Blank Aqueous Barium 6020B 2.8 J ug/L 78 (286 detections) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 10 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-001 Description: DPL-1 Matrix: Aqueous Date Sampled:04/28/2021 1515 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 2 5030B 8260D (SIM) 1 05/04/2021 2318 CJL2 91160 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) ND 3.0 1.0 ug/L 2 Run 2 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 100 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211158 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 11 J 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 11 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-001 Description: DPL-1 Matrix: Aqueous Date Sampled:04/28/2021 1515 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211158 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 105 70-130 1,2-Dichloroethane-d4 90 70-130 Toluene-d8 95 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1833 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.80 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 85 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 55 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 4.0 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.6 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 2.1 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 53 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 12 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-001 Description: DPL-1 Matrix: Aqueous Date Sampled:04/28/2021 1515 Date Received:04/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1833 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 14 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 13 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-002 Description: MW-3 Matrix: Aqueous Date Sampled:04/28/2021 1430 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0245 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 95 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 98 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211223 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D 1.6 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 4.4 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D 3.2 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.83 J 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 7.2 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 1.3 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 0.65 J 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 14 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-002 Description: MW-3 Matrix: Aqueous Date Sampled:04/28/2021 1430 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211223 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.72 J 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 0.89 J 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 107 70-130 1,2-Dichloroethane-d4 93 70-130 Toluene-d8 96 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1839 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 240 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.19 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 15 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 32 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 15 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-002 Description: MW-3 Matrix: Aqueous Date Sampled:04/28/2021 1430 Date Received:04/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1839 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 6020B 1.9 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 25 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 16 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-003 Description: MW-4A Matrix: Aqueous Date Sampled:04/28/2021 1455 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0310 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 31 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 100 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211248 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D 5.6 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 28 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 4.4 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 25 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans-1,2-Dichloroethene 156-60-5 8260D 0.44 J 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 17 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-003 Description: MW-4A Matrix: Aqueous Date Sampled:04/28/2021 1455 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211248 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D 6.8 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 4.9 J 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D 2.7 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 1.0 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 12 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 110 70-130 1,2-Dichloroethane-d4 93 70-130 Toluene-d8 96 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1845 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 670 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.18 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 48 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 4.0 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 9.7 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 18 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-003 Description: MW-4A Matrix: Aqueous Date Sampled:04/28/2021 1455 Date Received:04/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1845 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 Silver 7440-22-4 Thallium 7440-28-0 Vanadium 7440-62-2 Zinc 7440-66-6 6020B ND 5.0 1.3 ug/L 1 6020B ND 1.0 0.25 ug/L 1 6020B ND 0.50 0.15 ug/L 1 6020B ND 5.0 2.5 ug/L 1 6020B 2.7 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 19 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-004 Description: MW-5 Matrix: Aqueous Date Sampled:04/28/2021 1355 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0334 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 73 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 98 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211313 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D 0.86 J 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 8.7 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D 1.0 J 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 4.8 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.51 J 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 20 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-004 Description: MW-5 Matrix: Aqueous Date Sampled:04/28/2021 1355 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211313 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 111 70-130 1,2-Dichloroethane-d4 95 70-130 Toluene-d8 99 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1851 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 170 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 11 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 19 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 21 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-004 Description: MW-5 Matrix: Aqueous Date Sampled:04/28/2021 1355 Date Received:04/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1851 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 6020B 2.1 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 22 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-005 Description: MW-6-192 Matrix: Aqueous Date Sampled:04/28/2021 1615 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 2 5030B 8260D (SIM) 1 05/04/2021 2342 CJL2 91160 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 5.6 3.0 1.0 ug/L 2 Run 2 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 100 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211338 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.96 J 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.65 J 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.43 J 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.69 J 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 23 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-005 Description: MW-6-192 Matrix: Aqueous Date Sampled:04/28/2021 1615 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211338 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 109 70-130 1,2-Dichloroethane-d4 95 70-130 Toluene-d8 98 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1857 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 61 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.5 J 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 24 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-005 Description: MW-6-192 Matrix: Aqueous Date Sampled:04/28/2021 1615 Date Received:04/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1857 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 25 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-006 Description: MW-7 Matrix: Aqueous Date Sampled:04/28/2021 1700 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20210312 CJL2 91967 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D 2.4 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D 13 1.0 0.40 ug/L Chloroethane 75-00-3 8260D 3.4 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D 5.8 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D 2.1 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1, 1 -Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis-1,2-Dichloroethene 156-59-2 8260D 20 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 26 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-006 Description: MW-7 Matrix: Aqueous Date Sampled:04/28/2021 1700 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20210312 CJL2 91967 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.60 J 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 0.54 J 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 100 70-130 1,2-Dichloroethane-d4 109 70-130 Toluene-d8 106 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1903 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 180 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.20 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.14 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 200 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 14 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.45 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 57 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 13 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 27 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-007 Description: MW-15 Matrix: Aqueous Date Sampled:04/28/2021 1305 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20210337 CJL2 91967 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 12 J 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 28 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-007 Description: MW-15 Matrix: Aqueous Date Sampled:04/28/2021 1305 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20210337 CJL2 91967 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 100 70-130 1,2-Dichloroethane-d4 109 70-130 Toluene-d8 107 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1407 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 220 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 12 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.2 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND S 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 29 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-009 Description: MW-2 Matrix: Aqueous Date Sampled:04/29/2021 1000 )ate Received:04/30/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/01/2021 1458 DAK 90903 1 (BOD, 5 day) SM 521OB-2011 1 05/05/2021 1709 SJL 04/30/2021 1957 90831 1 (Chloride) 9056A 1 05/01/2021 0646 AMR 90993 1 (COD) SM 5220D-2011 1 05/04/2021 1527 AMR 91121 1 (Nitrate - N) 9056A 1 05/01/2021 0646 AMR 90992 1 (Sulfate) 9056A 1 05/01/2021 0646 AMR 90994 1 (Sulfide) SM 4500-S2 F-2011 1 05/05/2021 2008 GDC 91461 1 (TOC) SM 531OC-2011 1 05/01/2021 0013 AAB 90858 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 232OB-2011 64 20 20 mg CaCO3/L 1 BOD, 5 day SM 521OB-2011 ND 47 2.0 0.18 mg/L 1 Chloride 9056A 2.4 1.0 0.25 mg/L 1 COD SM 5220D-2011 ND 20 20 mg/L 1 Nitrate - N 9056A 0.027 0.020 0.0050 mg/L 1 Sulfate 9056A 3.2 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.2 1.0 1.0 mg/L 1 TOC SM 531OC-2011 11 1.0 1.0 mg/L 1 Volatile Organic Compounds by GUMS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20210402 CJL2 91967 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 30 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-009 Description: MW-2 Matrix: Aqueous Date Sampled:04/29/2021 1000 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20210402 CJL2 91967 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 102 70-130 1,2-Dichloroethane-d4 110 70-130 Toluene-d8 108 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1445 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 31 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-009 Description: MW-2 Matrix: Aqueous Date Sampled:04/29/2021 1000 Date Received:04/30/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1445 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 1.0 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 25 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.2 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 2.7 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.77 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 7.5 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 8.9 J 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L 7-SCF Out of range LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 32 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-010 Description: MW-6 Matrix: Aqueous Date Sampled:04/29/2021 1205 )ate Received:04/30/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/01/2021 1513 DAK 90903 1 (BOD, 5 day) SM 521OB-2011 1 05/05/2021 1711 SJL 04/30/2021 2010 90831 1 (Chloride) 9056A 1 05/01/2021 0846 AMR 90993 2 (COD) SM 5220D-2011 1 05/06/2021 0853 AMR 91352 2 (Nitrate - N) 9056A 10 05/04/2021 1557 AMR 91255 1 (Sulfate) 9056A 1 05/01/2021 0846 AMR 90994 1 (Sulfide) SM 4500-S2 F-2011 1 05/05/2021 2008 GDC 91461 1 (TOC) SM 531OC-2011 1 05/01/2021 0027 AAB 90858 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 570 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 6.6 47 2.0 0.18 mg/L 1 Chloride 9056A 160 1.0 0.25 mg/L 1 COD SM 5220D-2011 42 20 20 mg/L 2 Nitrate - N 9056A ND H 0.20 0.050 mg/L 2 Sulfate 9056A 1.1 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 ND 1.0 1.0 mg/L 1 TOC SM 531OC-2011 15 1.0 1.0 mg/L 1 Volatile Organic Compounds by GC/MS (SIM Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0423 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 33 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 99 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211248 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D 1.3 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 33 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-010 Description: MW-6 Matrix: Aqueous Date Sampled:04/29/2021 1205 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211248 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D 4.2 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D 7.5 1.0 0.40 ug/L Chloroethane 75-00-3 8260D 3.5 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D 2.6 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D 1.8 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis-1,2-Dichloroethene 156-59-2 8260D 1.4 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D 0.87 BJ 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 34 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-010 Description: MW-6 Matrix: Aqueous Date Sampled:04/29/2021 1205 Date Received:04/30/2021 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 98 70-130 1,2-Dichloroethane-d4 87 70-130 Toluene-d8 89 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1452 BPK 05/07/2021 0324 90837 2 3005A 6020B 10 05/07/2021 1721 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 1700 50 13 ug/L 2 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 11 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 1.3 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 6.1 J 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L 7-SCF Out of range LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 35 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-011 Description: MW-4 Matrix: Aqueous Date Sampled:04/29/2021 1410 )ate Received:04/30/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/01/2021 1530 DAK 90903 1 (BOD, 5 day) SM 521OB-2011 1 05/05/2021 2027 SJL 04/30/2021 2311 90869 1 (Chloride) 9056A 1 05/01/2021 1005 AMR 90993 2 (COD) SM 5220D-2011 1 05/06/2021 0854 AMR 91352 1 (Nitrate - N) 9056A 1 05/01/2021 1005 AMR 90992 1 (Sulfate) 9056A 1 05/01/2021 1005 AMR 90994 1 (Sulfide) SM 4500-S2 F-2011 1 05/05/2021 2008 GDC 91461 1 (TOC) SM 531OC-2011 1 05/01/2021 0106 AAB 90858 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 450 20 20 mg CaCO3/L 1 BOD, 5 day SM 521OB-2011 ND 2.0 0.18 mg/L 1 Chloride 9056A 0.32 J 1.0 0.25 mg/L 1 COD SM 5220D-2011 20 20 20 mg/L 2 Nitrate - N 9056A ND 0.020 0.0050 mg/L 1 Sulfate 9056A ND 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 ND 1.0 1.0 mg/L 1 TOC SM 531OC-2011 6.3 1.0 1.0 mg/L 1 Volatile Organic Compounds by GC/MS (SIM Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0448 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 24 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 100 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211313 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D 0.86 J 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 36 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-011 Description: MW-4 Matrix: Aqueous Date Sampled:04/29/2021 1410 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211313 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D 6.0 1.0 0.40 ug/L Chloroethane 75-00-3 8260D 2.0 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D 0.73 J 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D 9.5 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D 7.2 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis-1,2-Dichloroethene 156-59-2 8260D 16 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D 1.2 B 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D 0.82 J 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D 3.0 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 37 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-011 Description: MW-4 Matrix: Aqueous Date Sampled:04/29/2021 1410 Date Received:04/30/2021 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 106 70-130 1,2-Dichloroethane-d4 92 70-130 Toluene-d8 97 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1459 BPK 05/07/2021 0324 90837 2 3005A 6020B 10 05/07/2021 1728 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 630 50 13 ug/L 2 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.84 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 76 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 93 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 17 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 38 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-012 Description: MW-B Matrix: Aqueous Date Sampled:04/29/2021 1630 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0513 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 22 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 102 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211338 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.61 J 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.75 J 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 4.7 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 39 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-012 Description: MW-B Matrix: Aqueous Date Sampled:04/29/2021 1630 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211338 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.68 BJ 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 2.3 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 103 70-130 1,2-Dichloroethane-d4 90 70-130 Toluene-d8 94 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1522 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 1.4 J 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 290 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 40 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-012 Description: MW-B Matrix: Aqueous Date Sampled:04/29/2021 1630 Date Received:04/30/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1522 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 41 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-013 Description: MW-12-25 Matrix: Aqueous Date Sampled:04/29/2021 0930 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211403 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1, 1 -Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis-1,2-Dichloroethene 156-59-2 8260D 0.57 J 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D 0.63 BJ 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 42 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-013 Description: MW-12-25 Matrix: Aqueous Date Sampled:04/29/2021 0930 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211403 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 104 70-130 1,2-Dichloroethane-d4 91 70-130 Toluene-d8 96 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1529 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 58 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.3 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 15 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 9.1 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 43 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-014 Description: MW-13-35 Matrix: Aqueous Date Sampled:04/29/2021 1030 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211428 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D 1.1 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D 5.0 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D 3.1 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D 16 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1, 1 -Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis-1,2-Dichloroethene 156-59-2 8260D 2.7 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D 0.66 BJ 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 44 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-014 Description: MW-13-35 Matrix: Aqueous Date Sampled:04/29/2021 1030 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211428 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.61 J 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 104 70-130 1,2-Dichloroethane-d4 92 70-130 Toluene-d8 97 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1537 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 180 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 1.3 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 4.8 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 8.0 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 45 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-015 Description: MW-13-132 Matrix: Aqueous Date Sampled:04/29/2021 1355 )ate Received:04/30/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/01/2021 1537 DAK 90903 1 (BOD, 5 day) SM 521OB-2011 1 05/05/2021 2028 SJL 04/30/2021 2315 90869 2 (Chloride) 9056A 1 05/04/2021 1617 AMR 91200 1 (COD) SM 5220D-2011 1 05/04/2021 1527 AMR 91121 1 (Nitrate - N) 9056A 5 05/01/2021 0746 AMR 90992 1 (Sulfate) 9056A 5 05/01/2021 0746 AMR 90994 1 (Sulfide) SM 4500-S2 F-2011 1 05/05/2021 2008 GDC 91461 1 (TOC) SM 531OC-2011 1 05/01/2021 0119 AAB 90858 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 232OB-2011 150 20 20 mg CaCO3/L 1 BOD, 5 day SM 521OB-2011 ND 2.0 0.18 mg/L 1 Chloride 9056A 5.1 1.0 0.25 mg/L 2 COD SM 5220D-2011 ND 20 20 mg/L 1 Nitrate - N 9056A 0.028 J 0.10 0.025 mg/L 1 Sulfate 9056A 7.8 5.0 1.3 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 ND 1.0 1.0 mg/L 1 TOC SM 531OC-2011 1.1 1.0 1.0 mg/L 1 Volatile Organic Compounds by GUMS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211453 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D 1.0 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 2.7 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 46 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-015 Description: MW-13-132 Matrix: Aqueous Date Sampled:04/29/2021 1355 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211453 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D 0.58 J 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis-1,2-Dichloroethene 156-59-2 8260D 2.6 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D 0.53 BJ 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D 0.91 J 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 105 70-130 1,2-Dichloroethane-d4 89 70-130 Toluene-d8 95 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1544 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 47 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-015 Description: MW-13-132 Matrix: Aqueous Date Sampled:04/29/2021 1355 Date Received:04/30/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1544 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 41 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 2.2 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 6.9 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 48 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-016 Description: MW-17-60 Matrix: Aqueous Date Sampled:04/29/2021 1455 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0538 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 26 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 101 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211518 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.53 J 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 1.1 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 2.5 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 49 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-016 Description: MW-17-60 Matrix: Aqueous Date Sampled:04/29/2021 1455 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211518 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.54 BJ 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 1.2 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 109 70-130 1,2-Dichloroethane-d4 94 70-130 Toluene-d8 101 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1551 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 24 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 50 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-016 Description: MW-17-60 Matrix: Aqueous Date Sampled:04/29/2021 1455 Date Received:04/30/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1551 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 51 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-017 Description: MW-17-137 Matrix: Aqueous Date Sampled:04/29/2021 1355 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0602 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 35 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 100 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211543 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.43 J 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.68 J 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.78 J 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 0.61 J 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 52 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-017 Description: MW-17-137 Matrix: Aqueous Date Sampled:04/29/2021 1355 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211543 BWS 92056 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.51 BJ 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.74 J 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 0.46 J 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 107 70-130 1,2-Dichloroethane-d4 95 70-130 Toluene-d8 99 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1559 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 24 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 53 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-017 Description: MW-17-137 Matrix: Aqueous Date Sampled:04/29/2021 1355 Date Received:04/30/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1559 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 54 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-018 Description: MW-17-310 Matrix: Aqueous Date Sampled:04/29/2021 1310 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211510 TML 92034 2 5030B 8260D 1 05/13/20211411 BWS 92201 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D 3.4 J 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 55 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-018 Description: MW-17-310 Matrix: Aqueous Date Sampled:04/29/2021 1310 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20211510 TML 92034 2 5030B 8260D 1 05/13/20211411 BWS 92201 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 98 70-130 112 70-130 1,2-Dichloroethane-d4 92 70-130 91 70-130 Toluene-d8 96 70-130 98 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1606 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 3.3 J 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.31 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 3.1 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 56 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-019 Description: MW-18-78 Matrix: Aqueous Date Sampled:04/29/2021 1010 )ate Received:04/30/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/01/2021 1545 DAK 90903 1 (BOD, 5 day) SM 521OB-2011 1 05/05/2021 2032 SJL 04/30/2021 2321 90869 1 (Chloride) 9056A 1 05/01/2021 0706 AMR 90993 2 (COD) SM 5220D-2011 1 05/06/2021 0854 AMR 91352 1 (Nitrate - N) 9056A 1 05/01/2021 0706 AMR 90992 1 (Sulfate) 9056A 1 05/01/2021 0706 AMR 90994 1 (Sulfide) SM 4500-S2 F-2011 1 05/05/2021 2008 GDC 91461 1 (TOC) SM 531OC-2011 1 05/01/2021 0132 AAB 90858 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 300 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.7 2.0 0.18 mg/L 1 Chloride 9056A 150 1.0 0.25 mg/L 1 COD SM 5220D-2011 33 20 20 mg/L 2 Nitrate - N 9056A ND 0.020 0.0050 mg/L 1 Sulfate 9056A 2.2 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 3.7 1.0 1.0 mg/L 1 TOC SM 531OC-2011 8.9 1.0 1.0 mg/L 1 Volatile Organic Compounds by GC/MS (SIM Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0627 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 53 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 100 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210245 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D 0.53 J 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 57 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-019 Description: MW-18-78 Matrix: Aqueous Date Sampled:04/29/2021 1010 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210245 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D 4.0 1.0 0.40 ug/L Chloroethane 75-00-3 8260D 0.70 J 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND L 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D 3.1 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D 0.98 J 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis-1,2-Dichloroethene 156-59-2 8260D 0.95 J 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D 0.83 J 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 58 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-019 Description: MW-18-78 Matrix: Aqueous Date Sampled:04/29/2021 1010 Date Received:04/30/2021 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 96 70-130 1,2-Dichloroethane-d4 92 70-130 Toluene-d8 98 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1614 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 75 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 7.2 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 59 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-020 Description: MW-19-75 Matrix: Aqueous Date Sampled:04/29/2021 1145 )ate Received:04/30/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/01/2021 1552 DAK 90903 1 (BOD, 5 day) SM 521OB-2011 1 05/05/2021 2035 SJL 04/30/2021 2327 90869 1 (Chloride) 9056A 1 05/01/2021 0906 AMR 90993 2 (COD) SM 5220D-2011 1 05/06/2021 0854 AMR 91352 1 (Nitrate - N) 9056A 1 05/01/2021 0906 AMR 90992 1 (Sulfate) 9056A 1 05/01/2021 0906 AMR 90994 1 (Sulfide) SM 4500-S2 F-2011 1 05/05/2021 2008 GDC 91461 1 (TOC) SM 531OC-2011 1 05/01/2021 0145 AAB 90858 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 410 20 20 mg CaCO3/L 1 BOD, 5 day SM 521OB-2011 ND 2.0 0.18 mg/L 1 Chloride 9056A 150 1.0 0.25 mg/L 1 COD SM 5220D-2011 40 20 20 mg/L 2 Nitrate - N 9056A 0.012 J 0.020 0.0050 mg/L 1 Sulfate 9056A 17 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 ND 1.0 1.0 mg/L 1 TOC SM 531OC-2011 12 1.0 1.0 mg/L 1 Volatile Organic Compounds by GC/MS (SIM Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0651 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 87 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 100 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210308 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 5.2 JL 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 60 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-020 Description: MW-19-75 Matrix: Aqueous Date Sampled:04/29/2021 1145 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210308 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D 4.2 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND L 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D 3.2 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D 0.47 J 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 61 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-020 Description: MW-19-75 Matrix: Aqueous Date Sampled:04/29/2021 1145 Date Received:04/30/2021 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 91 70-130 Toluene-d8 95 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1621 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 120 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 3.4 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 22 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.5 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 62 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-021 Description: MW-19-110 Matrix: Aqueous Date Sampled:04/29/2021 1310 )ate Received:04/30/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/01/2021 1559 DAK 90903 1 (BOD, 5 day) SM 521OB-2011 1 05/05/2021 2055 SJL 04/30/2021 2334 90869 1 (Chloride) 9056A 1 05/01/2021 0925 AMR 90993 2 (COD) SM 5220D-2011 1 05/06/2021 0854 AMR 91352 1 (Nitrate - N) 9056A 1 05/01/2021 0925 AMR 90992 1 (Sulfate) 9056A 1 05/01/2021 0925 AMR 90994 1 (Sulfide) SM 4500-S2 F-2011 1 05/05/2021 2008 GDC 91461 1 (TOC) SM 531OC-2011 1 05/01/2021 0158 AAB 90858 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 232OB-2011 170 20 20 mg CaCO3/L 1 BOD, 5 day SM 521OB-2011 ND 2.0 0.18 mg/L 1 Chloride 9056A 41 1.0 0.25 mg/L 1 COD SM 5220D-2011 ND 20 20 mg/L 2 Nitrate - N 9056A ND 0.020 0.0050 mg/L 1 Sulfate 9056A 12 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 ND 1.0 1.0 mg/L 1 TOC SM 531OC-2011 2.8 1.0 1.0 mg/L 1 Volatile Organic Compounds by GC/MS (SIM Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0716 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 35 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 100 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210330 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 63 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-021 Description: MW-19-110 Matrix: Aqueous Date Sampled:04/29/2021 1310 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210330 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D 0.78 J 1.0 0.40 ug/L Chloroethane 75-00-3 8260D 0.87 J 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND L 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D 0.76 J 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1, 1 -Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis-1,2-Dichloroethene 156-59-2 8260D 0.93 J 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 64 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-021 Description: MW-19-110 Matrix: Aqueous Date Sampled:04/29/2021 1310 Date Received:04/30/2021 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 97 70-130 1,2-Dichloroethane-d4 93 70-130 Toluene-d8 98 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1629 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 11 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 4.1 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 7.5 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 65 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-022 Description: MW-21-21 Matrix: Aqueous Date Sampled:04/29/2021 1220 )ate Received:04/30/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/01/2021 1609 DAK 90903 1 (BOD, 5 day) SM 521OB-2011 1 05/05/2021 2100 SJL 04/30/2021 2336 90869 1 (Chloride) 9056A 5 05/01/2021 0945 AMR 90993 1 (COD) SM 5220D-2011 1 05/04/2021 1543 AMR 91123 1 (Nitrate - N) 9056A 5 05/01/2021 0945 AMR 90992 1 (Sulfate) 9056A 5 05/01/2021 0945 AMR 90994 1 (Sulfide) SM 4500-S2 F-2011 1 05/05/2021 2008 GDC 91461 1 (TOC) SM 531OC-2011 1 05/01/2021 0211 AAB 90858 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 770 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 3.7 2.0 0.18 mg/L 1 Chloride 9056A 70 5.0 1.3 mg/L 1 COD SM 5220D-2011 58 20 20 mg/L 1 Nitrate - N 9056A ND 0.10 0.025 mg/L 1 Sulfate 9056A 23 5.0 1.3 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.5 1.0 1.0 mg/L 1 TOC SM 531OC-2011 15 1.0 1.0 mg/L 1 Volatile Organic Compounds by GC/MS (SIM Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0741 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 30 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 100 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210352 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D 2.8 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 66 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-022 Description: MW-21-21 Matrix: Aqueous Date Sampled:04/29/2021 1220 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210352 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D 0.53 J 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D 32 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND L 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D 4.0 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D 14 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D 2.8 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D 0.43 J 1.0 0.40 ug/L 1, 1 -Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis-1,2-Dichloroethene 156-59-2 8260D 5.8 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D 0.66 J 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D 0.51 J 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D 2.2 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D 0.60 J 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 67 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-022 Description: MW-21-21 Matrix: Aqueous Date Sampled:04/29/2021 1220 Date Received:04/30/2021 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 92 70-130 Toluene-d8 96 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1651 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 120 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 12 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 4.6 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 2.7 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 68 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-023 Description: MW-21-94 Matrix: Aqueous Date Sampled:04/29/2021 1045 )ate Received:04/30/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/01/2021 1617 DAK 90903 1 (BOD, 5 day) SM 521OB-2011 1 05/05/2021 2106 SJL 04/30/2021 2359 90869 1 (Chloride) 9056A 1 05/01/2021 0726 AMR 90993 2 (COD) SM 5220D-2011 1 05/06/2021 0855 AMR 91352 1 (Nitrate - N) 9056A 1 05/01/2021 0726 AMR 90992 1 (Sulfate) 9056A 1 05/01/2021 0726 AMR 90994 1 (Sulfide) SM 4500-S2 F-2011 1 05/05/2021 2008 GDC 91461 1 (TOC) SM 531OC-2011 1 05/01/2021 0225 AAB 90858 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 310 20 20 mg CaCO3/L 1 BOD, 5 day SM 521OB-2011 ND 2.0 0.18 mg/L 1 Chloride 9056A 98 1.0 0.25 mg/L 1 COD SM 5220D-2011 28 20 20 mg/L 2 Nitrate - N 9056A ND 0.020 0.0050 mg/L 1 Sulfate 9056A 3.3 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 2.6 1.0 1.0 mg/L 1 TOC SM 531OC-2011 7.3 1.0 1.0 mg/L 1 Volatile Organic Compounds by GC/MS (SIM Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 1320 TML 91095 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 46 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 100 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210415 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 69 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-023 Description: MW-21-94 Matrix: Aqueous Date Sampled:04/29/2021 1045 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210415 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D 1.8 1.0 0.40 ug/L Chloroethane 75-00-3 8260D 2.3 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND L 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D 0.44 J 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D 2.8 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D 1.2 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D 0.42 J 1.0 0.40 ug/L 1, 1 -Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis-1,2-Dichloroethene 156-59-2 8260D 2.9 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D 1.2 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 70 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-023 Description: MW-21-94 Matrix: Aqueous Date Sampled:04/29/2021 1045 Date Received:04/30/2021 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 96 70-130 1,2-Dichloroethane-d4 93 70-130 Toluene-d8 97 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1658 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 47 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 8.0 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 71 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-024 Description: MW-24-160 Matrix: Aqueous Date Sampled:04/29/2021 1645 )ate Received:04/30/2021 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 05/01/2021 1623 DAK 90903 1 (BOD, 5 day) SM 521OB-2011 1 05/05/2021 2108 SJL 05/01/2021 0001 90869 1 (Chloride) 9056A 1 05/01/2021 1025 AMR 90993 1 (COD) SM 5220D-2011 1 05/04/2021 1527 AMR 91121 1 (Nitrate - N) 9056A 1 05/01/2021 1025 AMR 90992 1 (Sulfate) 9056A 1 05/01/2021 1025 AMR 90994 1 (Sulfide) SM 4500-S2 F-2011 1 05/05/2021 2008 GDC 91461 1 (TOC) SM 531OC-2011 1 05/01/2021 0238 AAB 90858 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 232OB-2011 70 20 20 mg CaCO3/L 1 BOD, 5 day SM 521OB-2011 ND 2.0 0.18 mg/L 1 Chloride 9056A 6.5 1.0 0.25 mg/L 1 COD SM 5220D-2011 ND 20 20 mg/L 1 Nitrate - N 9056A ND 0.020 0.0050 mg/L 1 Sulfate 9056A 23 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.8 1.0 1.0 mg/L 1 TOC SM 531OC-2011 1.4 1.0 1.0 mg/L 1 Volatile Organic Compounds by GUMS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210437 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 72 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-024 Description: MW-24-160 Matrix: Aqueous Date Sampled:04/29/2021 1645 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210437 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND L 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 99 70-130 1,2-Dichloroethane-d4 92 70-130 Toluene-d8 96 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1706 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 73 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-024 Description: MW-24-160 Matrix: Aqueous Date Sampled:04/29/2021 1645 Date Received:04/30/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1706 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 27 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.3 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.74 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.6 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 7.2 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 74 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-025 Description: Field Blank Matrix: Aqueous Date Sampled:04/29/2021 1300 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20211136 BWS 92172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND L 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND L 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 75 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-025 Description: Field Blank Matrix: Aqueous Date Sampled:04/29/2021 1300 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20211136 BWS 92172 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 101 70-130 1,2-Dichloroethane-d4 108 70-130 Toluene-d8 106 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/07/2021 1713 BPK 05/07/2021 0324 90837 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 2.8 J 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 76 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-026 Description: Trip Blank Matrix: Aqueous Date Sampled:04/29/2021 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210201 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND L 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 77 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-026 Description: Trip Blank Matrix: Aqueous Date Sampled:04/29/2021 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210201 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 95 70-130 90 70-130 94 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 78 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-027 Description: Trip Blank Matrix: Aqueous Date Sampled:04/29/2021 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210223 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND L 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND L 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 79 of 175 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30017-027 Description: Trip Blank Matrix: Aqueous Date Sampled:04/29/2021 Date Received:04/30/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/13/20210223 JDF 92125 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 97 70-130 92 70-130 98 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 80 of 175 QC Summary Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 81 of 175 Inorganic non-metals - BOD Blank and GGA Matrix: Aqueous Batch: 90831 SCF: 0.6 Analytical Method: SM 521 OB-2011 SCF Range: 0.6 - 1.0 Result Avg. Result Sample ID Depl Avg. Depl (mg/L) (mg/L) Q Limit Prep Date Analysis Date WQ90831-041 (Blank) 0.21 4 0.2 04/30/2021 1809 05/05/2021 1556 WQ90831-141 (Blank) 0.26 4 0.2 04/30/2021 1809 05/05/2021 1556 WQ90831-241 (Blank) 0.21 0.23 4 0.2 04/30/2021 1809 05/05/2021 1556 WQ90831-035 (GGA) 169.2 47 167.5-228.5 04/30/2021 1816 05/05/2021 1600 WQ90831-135 (GGA) 180.2 47 167.5-228.5 04/30/2021 1816 05/05/2021 1559 WQ90831-235 (GGA) 191.7 180.4 47 167.5-228.5 04/30/2021 1817 05/05/2021 1600 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 82 of 175 Inorganic non-metals - MB Sample ID: WQ90858-001 Matrix: Aqueous Batch: 90858 Analytical Method: SM 531 OC-2011 Parameter Result Q Dil LOQ DL Units Analysis Date TOC ND 1 1.0 1.0 mg/L 04/30/2021 2241 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 83 of 175 Inorganic non-metals - LCS Sample ID: WQ90858-002 Matrix: Aqueous Batch: 90858 Analytical Method: SM 531 OC-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date TOC 20 19 1 97 90-110 04/30/2021 2254 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 84 of 175 Inorganic non-metals - BOD Blank and GGA Matrix: Aqueous Batch: 90869 SCF: 0.5 Analytical Method: SM 521 OB-2011 SCF Range: 0.6 - 1.0 Result Avg. Result Sample ID Depl Avg. Depl (mg/L) (mg/L) Q Limit Prep Date Analysis Date WQ90869-041 (Blank) 0.31 4 0.2 04/30/2021 2255 05/05/2021 2016 WQ90869-141 (Blank) 0.17 0.2 04/30/2021 2255 05/05/2021 2016 WQ90869-241 (Blank) 0.05 0.18 0.2 04/30/2021 2256 05/05/2021 2016 WQ90869-035 (GGA) 162.1 1 167.5-228.5 04/30/2021 2302 05/05/2021 2020 WQ90869-135 (GGA) 178.6 167.5-228.5 04/30/2021 2302 05/05/2021 2020 WQ90869-235 (GGA) 181.6 174.1 167.5-228.5 04/30/2021 2303 05/05/2021 2020 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 85 of 175 Inorganic non-metals - LCS Sample ID: WQ90903-002 Matrix: Aqueous Batch: 90903 Analytical Method: SM 2320B-2011 Spike Amount Result %Rec Parameter (mg CaCO3/L) (mg CaCO3/L) Q Dil % Rec Limit Analysis Date Alkalinity @ pH 4.5 su 100 100 1 100 90-110 05/01/2021 1419 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 86 of 175 Inorganic non-metals - Duplicate Sample ID: WD30017-009DU Matrix: Aqueous Batch: 90903 Analytical Method: SM 2320B-2011 Sample Amount Result %RPD Parameter (mg CaCO3/L) (mg CaCO3/L) 0 Dil % RPD Limit Analysis Date Alkalinity @ pH 4.5 su 64 64 1 0.090 20 05/01/2021 1505 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 87 of 175 Inorganic non-metals - MB Sample ID: WQ90992-001 Matrix: Aqueous Batch: 90992 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N ND 1 0.020 0.0050 mg/L 05/01/2021 0426 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 88 of 175 Inorganic non-metals - LCS Sample ID: WQ90992-002 Matrix: Aqueous Batch: 90992 Analytical Method: 9056A Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Nitrate - N 0.80 0.85 1 106 80-120 05/01/2021 0606 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 89 of 175 Inorganic non-metals - LCSD Sample ID: WQ90992-003 Matrix: Aqueous Batch: 90992 Analytical Method: 9056A Spike Amount Result %Rec % RPD Parameter (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Nitrate - N 0.80 0.81 1 101 4.8 80-120 20 05/01/2021 0626 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 90 of 175 Inorganic non-metals - MB Sample ID: WQ90993-001 Matrix: Aqueous Batch: 90993 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Chloride ND 1 1.0 0.25 mg/L 05/01/2021 0426 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 91 of 175 Inorganic non-metals - LCS Sample ID: WQ90993-002 Matrix: Aqueous Batch: 90993 Analytical Method: 9056A Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Chloride 20 21 1 103 80-120 05/01/2021 0606 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 92 of 175 Inorganic non-metals - LCSD Sample ID: WQ90993-003 Matrix: Aqueous Batch: 90993 Analytical Method: 9056A Spike Amount Result %Rec % RPD Parameter (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Chloride 20 20 1 102 0.24 80-120 20 05/01/2021 0626 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 93 of 175 Inorganic non-metals - MB Sample ID: WQ90994-001 Matrix: Aqueous Batch: 90994 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate ND 1 1.0 0.25 mg/L 05/01/2021 0426 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 94 of 175 Inorganic non-metals - LCS Sample ID: WQ90994-002 Matrix: Aqueous Batch: 90994 Analytical Method: 9056A Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfate 20 20 1 102 80-120 05/01/2021 0606 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 95 of 175 Inorganic non-metals - LCSD Sample ID: WQ90994-003 Matrix: Aqueous Batch: 90994 Analytical Method: 9056A Spike Amount Result %Rec % RPD Parameter (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Sulfate 20 20 1 102 0.24 80-120 20 05/01/2021 0626 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 96 of 175 Inorganic non-metals - MB Sample ID: WQ91121-001 Matrix: Aqueous Batch: 91121 Analytical Method: SM 5220D-2011 Parameter Result Q Dil LOQ DL Units Analysis Date COD ND 1 20 20 mg/L 05/04/2021 1524 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 97 of 175 Inorganic non-metals - LCS Sample ID: WQ91121-002 Matrix: Aqueous Batch: 91121 Analytical Method: SM 5220D-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date COD 40 41 1 102 95-105 05/04/2021 1524 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 98 of 175 Inorganic non-metals - MB Sample ID: WQ91200-001 Matrix: Aqueous Batch: 91200 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Chloride ND 1 1.0 0.25 mg/L 05/04/2021 1257 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 99 of 175 Inorganic non-metals - LCS Sample ID: WQ91200-002 Matrix: Aqueous Batch: 91200 Analytical Method: 9056A Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Chloride 20 21 1 103 80-120 05/04/2021 1337 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 100 of 175 Inorganic non-metals - MS Sample ID: WD30017-015MS Matrix: Aqueous Batch: 91200 Analytical Method: 9056A Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Chloride 5.1 10 15 1 102 80-120 05/04/2021 1716 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 101 of 175 Inorganic non-metals - MSD Sample ID: WD30017-015MD Matrix: Aqueous Batch: 91200 Analytical Method: 9056A Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Chloride 5.1 10 15 1 102 0.42 80-120 20 05/04/2021 1736 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 102 of 175 Inorganic non-metals - MB Sample ID: WQ91255-001 Matrix: Aqueous Batch: 91255 Analytical Method: 9056A Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N ND 1 0.020 0.0050 mg/L 05/04/2021 1257 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 103 of 175 Inorganic non-metals - LCS Sample ID: WQ91255-002 Matrix: Aqueous Batch: 91255 Analytical Method: 9056A Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Nitrate - N 0.80 0.88 1 110 80-120 05/04/2021 1337 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 104 of 175 Inorganic non-metals - MB Sample ID: WQ91352-001 Matrix: Aqueous Batch: 91352 Analytical Method: SM 5220D-2011 Parameter Result Q Dil LOQ DL Units Analysis Date COD ND 1 20 20 mg/L 05/06/2021 0852 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 105 of 175 Inorganic non-metals - LCS Sample ID: WQ91352-002 Matrix: Aqueous Batch: 91352 Analytical Method: SM 5220D-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date COD 40 39 1 96 95-105 05/06/2021 0853 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 106 of 175 Inorganic non-metals - MB Sample ID: WQ91461-001 Matrix: Aqueous Batch: 91461 Analytical Method: SM 4500-S2 F-2011 Parameter Result Q Dil LOQ DL Units Analysis Date Sulfide ND 1 1.0 1.0 mg/L 05/05/2021 2008 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 107 of 175 Inorganic non-metals - LCS Sample ID: WQ91461-002 Matrix: Aqueous Batch: 91461 Analytical Method: SM 4500-S2 F-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfide 10 10 1 100 80-120 05/05/2021 2008 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 108 of 175 Inorganic non-metals - LCSD Sample ID: WQ91461-003 Matrix: Aqueous Batch: 91461 Analytical Method: SM 4500-S2 F-2011 Spike Amount Result %Rec % RPD Parameter (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Sulfide 10 10 1 100 0.00 80-120 20 05/05/2021 2008 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 109 of 175 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: WQ91037-001 Matrix: Aqueous Batch: 91037 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane ND 1 3.0 1.0 ug/L 05/03/2021 2257 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 93 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 110 of 175 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: WQ91037-002 Matrix: Aqueous Batch: 91037 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 46 1 93 70-130 05/03/2021 2155 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 96 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 111 of 175 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: WQ91095-001 Matrix: Aqueous Batch: 91095 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane ND 1 3.0 1.0 ug/L 05/04/2021 1018 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 98 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 112 of 175 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: WQ91095-002 Matrix: Aqueous Batch: 91095 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 50 1 100 70-130 05/04/2021 0915 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 103 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 113 of 175 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: WQ91160-001 Matrix: Aqueous Batch: 91160 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane ND 1 3.0 1.0 ug/L 05/04/2021 2219 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 96 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 114 of 175 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: WQ91160-002 Matrix: Aqueous Batch: 91160 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 47 1 94 70-130 05/04/2021 2122 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 95 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 115 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ91880-001 Matrix: Aqueous Batch: 91880 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 05/11/2021 0945 Acrylonitrile ND 1 20 0.80 ug/L 05/11/2021 0945 Benzene ND 1 1.0 0.40 ug/L 05/11/2021 0945 Bromochloromethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 Bromodichloromethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 Bromoform ND 1 1.0 0.40 ug/L 05/11/2021 0945 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 05/11/2021 0945 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/11/2021 0945 Carbon disulfide ND 1 1.0 0.40 ug/L 05/11/2021 0945 Carbon tetrachloride ND 1 1.0 0.40 ug/L 05/11/2021 0945 Chlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 0945 Chloroethane ND 1 2.0 0.40 ug/L 05/11/2021 0945 Chloroform ND 1 1.0 0.40 ug/L 05/11/2021 0945 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 05/11/2021 0945 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 05/11/2021 0945 Dibromochloromethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 05/11/2021 0945 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 05/11/2021 0945 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 05/11/2021 0945 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 0945 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 0945 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 05/11/2021 0945 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/11/2021 0945 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/11/2021 0945 Ethylbenzene ND 1 1.0 0.40 ug/L 05/11/2021 0945 2-Hexanone ND 1 10 2.0 ug/L 05/11/2021 0945 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/11/2021 0945 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/11/2021 0945 Methylene chloride ND 1 1.0 0.40 ug/L 05/11/2021 0945 Styrene ND 1 1.0 0.41 ug/L 05/11/2021 0945 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 Tetrachloroethene ND 1 1.0 0.40 ug/L 05/11/2021 0945 Toluene ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 Trichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 0945 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 05/11/2021 0945 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 116 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ91880-001 Matrix: Aqueous Batch: 91880 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 05/11/2021 0945 Vinyl chloride ND 1 1.0 0.40 ug/L 05/11/2021 0945 Xylenes (total) ND 1 1.0 0.40 ug/L 05/11/2021 0945 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 110 70-130 1,2-Dichloroethane-d4 97 70-130 Toluene-d8 100 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 117 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ91880-002 Matrix: Aqueous Batch: 91880 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 110 1 107 60-140 05/11/2021 0841 Acrylonitrile 100 100 1 105 70-130 05/11/2021 0841 Benzene 50 45 1 89 70-130 05/11/2021 0841 Bromochloromethane 50 47 1 93 70-130 05/11/2021 0841 Bromodichloromethane 50 48 1 95 70-130 05/11/2021 0841 Bromoform 50 45 1 90 70-130 05/11/2021 0841 Bromomethane (Methyl bromide) 50 45 1 89 70-130 05/11/2021 0841 2-Butanone (MEK) 100 100 1 102 70-130 05/11/2021 0841 Carbon disulfide 50 45 1 91 70-130 05/11/2021 0841 Carbon tetrachloride 50 43 1 87 70-130 05/11/2021 0841 Chlorobenzene 50 45 1 90 70-130 05/11/2021 0841 Chloroethane 50 43 1 86 70-130 05/11/2021 0841 Chloroform 50 44 1 87 70-130 05/11/2021 0841 Chloromethane (Methyl chloride) 50 43 1 86 60-140 05/11/2021 0841 1,2-Dibromo-3-chloropropane (DBCP) 50 52 1 105 70-130 05/11/2021 0841 Dibromochloromethane 50 50 1 100 70-130 05/11/2021 0841 1,2-Dibromoethane (EDB) 50 49 1 98 70-130 05/11/2021 0841 Dibromomethane (Methylene bromide) 50 47 1 93 70-130 05/11/2021 0841 trans- 1,4-Dichloro-2-butene 50 44 1 89 70-130 05/11/2021 0841 1,2-Dichlorobenzene 50 47 1 93 70-130 05/11/2021 0841 1,4-Dichlorobenzene 50 44 1 88 70-130 05/11/2021 0841 1,1-Dichloroethane 50 46 1 91 70-130 05/11/2021 0841 1,2-Dichloroethane 50 47 1 93 70-130 05/11/2021 0841 1,1-Dichloroethene 50 44 1 88 70-130 05/11/2021 0841 cis- 1,2-Dichloroethene 50 46 1 92 70-130 05/11/2021 0841 trans- 1,2-Dichloroethene 50 44 1 89 70-130 05/11/2021 0841 1,2-Dichloropropane 50 46 1 93 70-130 05/11/2021 0841 cis- 1,3-Dichloropropene 50 45 1 90 70-130 05/11/2021 0841 trans- 1,3-Dichloropropene 50 45 1 90 70-130 05/11/2021 0841 Ethylbenzene 50 46 1 93 70-130 05/11/2021 0841 2-Hexanone 100 100 1 101 70-130 05/11/2021 0841 Methyl iodide (lodomethane) 50 46 1 93 70-130 05/11/2021 0841 4-Methyl-2-pentanone 100 98 1 98 70-130 05/11/2021 0841 Methylene chloride 50 45 1 90 70-130 05/11/2021 0841 Styrene 50 52 1 104 70-130 05/11/2021 0841 1,1,1,2-Tetrachloroethane 50 49 1 98 70-130 05/11/2021 0841 1,1,2,2-Tetrachloroethane 50 50 1 99 70-130 05/11/2021 0841 Tetrachloroethene 50 44 1 88 70-130 05/11/2021 0841 Toluene 50 47 1 95 70-130 05/11/2021 0841 1,1,1-Trichloroethane 50 45 1 91 70-130 05/11/2021 0841 1,1,2-Trichloroethane 50 48 1 96 70-130 05/11/2021 0841 Trichloroethene 50 42 1 84 70-130 05/11/2021 0841 Trichlorofluoromethane 50 40 1 80 70-130 05/11/2021 0841 1,2,3-Trichloropropane 50 49 1 99 70-130 05/11/2021 0841 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 118 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ91880-002 Matrix: Aqueous Batch: 91880 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 47 1 93 60-140 05/11/2021 0841 Vinyl chloride 50 43 1 86 70-130 05/11/2021 0841 Xylenes (total) 100 98 1 98 70-130 05/11/2021 0841 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 89 70-130 Toluene-d8 90 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 119 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ91967-001 Matrix: Aqueous Batch: 91967 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 05/11/2021 2215 Acrylonitrile ND 1 20 0.80 ug/L 05/11/2021 2215 Benzene ND 1 1.0 0.40 ug/L 05/11/2021 2215 Bromochloromethane ND 1 1.0 0.40 ug/L 05/11/2021 2215 Bromodichloromethane ND 1 1.0 0.40 ug/L 05/11/2021 2215 Bromoform ND 1 1.0 0.40 ug/L 05/11/2021 2215 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 05/11/2021 2215 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/11/2021 2215 Carbon disulfide ND 1 1.0 0.40 ug/L 05/11/2021 2215 Carbon tetrachloride ND 1 1.0 0.40 ug/L 05/11/2021 2215 Chlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 2215 Chloroethane ND 1 2.0 0.40 ug/L 05/11/2021 2215 Chloroform ND 1 1.0 0.40 ug/L 05/11/2021 2215 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 05/11/2021 2215 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 05/11/2021 2215 Dibromochloromethane ND 1 1.0 0.40 ug/L 05/11/2021 2215 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 05/11/2021 2215 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 05/11/2021 2215 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 05/11/2021 2215 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 2215 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 2215 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 2215 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 2215 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 2215 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 2215 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 2215 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 05/11/2021 2215 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/11/2021 2215 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/11/2021 2215 Ethylbenzene ND 1 1.0 0.40 ug/L 05/11/2021 2215 2-Hexanone ND 1 10 2.0 ug/L 05/11/2021 2215 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/11/2021 2215 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/11/2021 2215 Methylene chloride ND 1 1.0 0.40 ug/L 05/11/2021 2215 Styrene ND 1 1.0 0.41 ug/L 05/11/2021 2215 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/11/2021 2215 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/11/2021 2215 Tetrachloroethene ND 1 1.0 0.40 ug/L 05/11/2021 2215 Toluene ND 1 1.0 0.40 ug/L 05/11/2021 2215 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 2215 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 2215 Trichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 2215 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 05/11/2021 2215 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 05/11/2021 2215 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 120 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ91967-001 Matrix: Aqueous Batch: 91967 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 05/11/2021 2215 Vinyl chloride ND 1 1.0 0.40 ug/L 05/11/2021 2215 Xylenes (total) ND 1 1.0 0.40 ug/L 05/11/2021 2215 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 102 70-130 1,2-Dichloroethane-d4 108 70-130 Toluene-d8 108 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 121 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ91967-002 Matrix: Aqueous Batch: 91967 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 100 1 100 60-140 05/11/2021 2043 Acrylonitrile 100 100 1 103 70-130 05/11/2021 2043 Benzene 50 50 1 101 70-130 05/11/2021 2043 Bromochloromethane 50 50 1 99 70-130 05/11/2021 2043 Bromodichloromethane 50 50 1 100 70-130 05/11/2021 2043 Bromoform 50 46 1 91 70-130 05/11/2021 2043 Bromomethane (Methyl bromide) 50 49 1 98 70-130 05/11/2021 2043 2-Butanone (MEK) 100 100 1 104 70-130 05/11/2021 2043 Carbon disulfide 50 51 1 101 70-130 05/11/2021 2043 Carbon tetrachloride 50 50 1 100 70-130 05/11/2021 2043 Chlorobenzene 50 50 1 100 70-130 05/11/2021 2043 Chloroethane 50 48 1 96 70-130 05/11/2021 2043 Chloroform 50 47 1 95 70-130 05/11/2021 2043 Chloromethane (Methyl chloride) 50 50 1 101 60-140 05/11/2021 2043 1,2-Dibromo-3-chloropropane (DBCP) 50 44 1 87 70-130 05/11/2021 2043 Dibromochloromethane 50 54 1 108 70-130 05/11/2021 2043 1,2-Dibromoethane (EDB) 50 51 1 102 70-130 05/11/2021 2043 Dibromomethane (Methylene bromide) 50 49 1 98 70-130 05/11/2021 2043 trans- 1,4-Dichloro-2-butene 50 51 1 102 70-130 05/11/2021 2043 1,2-Dichlorobenzene 50 48 1 97 70-130 05/11/2021 2043 1,4-Dichlorobenzene 50 48 1 95 70-130 05/11/2021 2043 1,1-Dichloroethane 50 49 1 98 70-130 05/11/2021 2043 1,2-Dichloroethane 50 49 1 97 70-130 05/11/2021 2043 1,1-Dichloroethene 50 52 1 104 70-130 05/11/2021 2043 cis- 1,2-Dichloroethene 50 48 1 95 70-130 05/11/2021 2043 trans- 1,2-Dichloroethene 50 51 1 102 70-130 05/11/2021 2043 1,2-Dichloropropane 50 49 1 99 70-130 05/11/2021 2043 cis- 1,3-Dichloropropene 50 54 1 108 70-130 05/11/2021 2043 trans- 1,3-Dichloropropene 50 48 1 96 70-130 05/11/2021 2043 Ethylbenzene 50 52 1 103 70-130 05/11/2021 2043 2-Hexanone 100 99 1 99 70-130 05/11/2021 2043 Methyl iodide (lodomethane) 50 52 1 104 70-130 05/11/2021 2043 4-Methyl-2-pentanone 100 110 1 107 70-130 05/11/2021 2043 Methylene chloride 50 49 1 98 70-130 05/11/2021 2043 Styrene 50 55 1 110 70-130 05/11/2021 2043 1,1,1,2-Tetrachloroethane 50 51 1 102 70-130 05/11/2021 2043 1,1,2,2-Tetrachloroethane 50 50 1 99 70-130 05/11/2021 2043 Tetrachloroethene 50 52 1 104 70-130 05/11/2021 2043 Toluene 50 51 1 102 70-130 05/11/2021 2043 1,1,1-Trichloroethane 50 52 1 103 70-130 05/11/2021 2043 1,1,2-Trichloroethane 50 51 1 102 70-130 05/11/2021 2043 Trichloroethene 50 51 1 102 70-130 05/11/2021 2043 Trichlorofluoromethane 50 50 1 100 70-130 05/11/2021 2043 1,2,3-Trichloropropane 50 50 1 99 70-130 05/11/2021 2043 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 122 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ91967-002 Matrix: Aqueous Batch: 91967 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 48 1 96 60-140 05/11/2021 2043 Vinyl chloride 50 50 1 100 70-130 05/11/2021 2043 Xylenes (total) 100 100 1 105 70-130 05/11/2021 2043 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 95 70-130 Toluene-d8 101 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 123 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ92034-001 Matrix: Aqueous Batch: 92034 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 05/12/2021 0944 Acrylonitrile ND 1 20 0.80 ug/L 05/12/2021 0944 Benzene ND 1 1.0 0.40 ug/L 05/12/2021 0944 Bromochloromethane ND 1 1.0 0.40 ug/L 05/12/2021 0944 Bromodichloromethane ND 1 1.0 0.40 ug/L 05/12/2021 0944 Bromoform ND 1 1.0 0.40 ug/L 05/12/2021 0944 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 05/12/2021 0944 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/12/2021 0944 Carbon disulfide ND 1 1.0 0.40 ug/L 05/12/2021 0944 Carbon tetrachloride ND 1 1.0 0.40 ug/L 05/12/2021 0944 Chlorobenzene ND 1 1.0 0.40 ug/L 05/12/2021 0944 Chloroethane ND 1 2.0 0.40 ug/L 05/12/2021 0944 Chloroform ND 1 1.0 0.40 ug/L 05/12/2021 0944 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 05/12/2021 0944 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 05/12/2021 0944 Dibromochloromethane ND 1 1.0 0.40 ug/L 05/12/2021 0944 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 05/12/2021 0944 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 05/12/2021 0944 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 05/12/2021 0944 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/12/2021 0944 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/12/2021 0944 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 05/12/2021 0944 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 05/12/2021 0944 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 05/12/2021 0944 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/12/2021 0944 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/12/2021 0944 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 05/12/2021 0944 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/12/2021 0944 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/12/2021 0944 Ethylbenzene ND 1 1.0 0.40 ug/L 05/12/2021 0944 2-Hexanone ND 1 10 2.0 ug/L 05/12/2021 0944 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/12/2021 0944 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/12/2021 0944 Methylene chloride ND 1 1.0 0.40 ug/L 05/12/2021 0944 Styrene ND 1 1.0 0.41 ug/L 05/12/2021 0944 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/12/2021 0944 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/12/2021 0944 Toluene ND 1 1.0 0.40 ug/L 05/12/2021 0944 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 05/12/2021 0944 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 05/12/2021 0944 Trichloroethene ND 1 1.0 0.40 ug/L 05/12/2021 0944 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 05/12/2021 0944 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 05/12/2021 0944 Vinyl acetate ND 1 5.0 1.2 ug/L 05/12/2021 0944 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 124 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ92034-001 Matrix: Aqueous Batch: 92034 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl chloride ND 1 1.0 0.40 ug/L 05/12/2021 0944 Xylenes (total) ND 1 1.0 0.40 ug/L 05/12/2021 0944 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 87 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 125 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ92034-002 Matrix: Aqueous Batch: 92034 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 88 1 88 60-140 05/12/2021 0824 Acrylonitrile 100 98 1 98 70-130 05/12/2021 0824 Benzene 50 50 1 101 70-130 05/12/2021 0824 Bromochloromethane 50 47 1 95 70-130 05/12/2021 0824 Bromodichloromethane 50 46 1 93 70-130 05/12/2021 0824 Bromoform 50 50 1 100 70-130 05/12/2021 0824 Bromomethane (Methyl bromide) 50 49 1 98 70-130 05/12/2021 0824 2-Butanone (MEK) 100 100 1 101 70-130 05/12/2021 0824 Carbon disulfide 50 56 1 113 70-130 05/12/2021 0824 Carbon tetrachloride 50 50 1 100 70-130 05/12/2021 0824 Chlorobenzene 50 48 1 97 70-130 05/12/2021 0824 Chloroethane 50 50 1 99 70-130 05/12/2021 0824 Chloroform 50 48 1 97 70-130 05/12/2021 0824 Chloromethane (Methyl chloride) 50 46 1 92 60-140 05/12/2021 0824 1,2-Dibromo-3-chloropropane (DBCP) 50 44 1 88 70-130 05/12/2021 0824 Dibromochloromethane 50 49 1 98 70-130 05/12/2021 0824 1,2-Dibromoethane (EDB) 50 49 1 98 70-130 05/12/2021 0824 Dibromomethane (Methylene bromide) 50 47 1 93 70-130 05/12/2021 0824 trans- 1,4-Dichloro-2-butene 50 46 1 92 70-130 05/12/2021 0824 1,2-Dichlorobenzene 50 49 1 98 70-130 05/12/2021 0824 1,4-Dichlorobenzene 50 50 1 99 70-130 05/12/2021 0824 1,1-Dichloroethane 50 53 1 106 70-130 05/12/2021 0824 1,2-Dichloroethane 50 45 1 90 70-130 05/12/2021 0824 1,1-Dichloroethene 50 51 1 102 70-130 05/12/2021 0824 cis- 1,2-Dichloroethene 50 51 1 102 70-130 05/12/2021 0824 trans- 1,2-Dichloroethene 50 53 1 107 70-130 05/12/2021 0824 1,2-Dichloropropane 50 48 1 96 70-130 05/12/2021 0824 cis- 1,3-Dichloropropene 50 50 1 100 70-130 05/12/2021 0824 trans- 1,3-Dichloropropene 50 49 1 98 70-130 05/12/2021 0824 Ethylbenzene 50 51 1 102 70-130 05/12/2021 0824 2-Hexanone 100 94 1 94 70-130 05/12/2021 0824 Methyl iodide (lodomethane) 50 52 1 103 70-130 05/12/2021 0824 4-Methyl-2-pentanone 100 94 1 94 70-130 05/12/2021 0824 Methylene chloride 50 48 1 96 70-130 05/12/2021 0824 Styrene 50 51 1 102 70-130 05/12/2021 0824 1,1,1,2-Tetrachloroethane 50 47 1 94 70-130 05/12/2021 0824 1,1,2,2-Tetrachloroethane 50 47 1 94 70-130 05/12/2021 0824 Toluene 50 50 1 100 70-130 05/12/2021 0824 1,1,1-Trichloroethane 50 50 1 100 70-130 05/12/2021 0824 1,1,2-Trichloroethane 50 47 1 93 70-130 05/12/2021 0824 Trichloroethene 50 49 1 98 70-130 05/12/2021 0824 Trichlorofluoromethane 50 45 1 89 70-130 05/12/2021 0824 1,2,3-Trichloropropane 50 44 1 88 70-130 05/12/2021 0824 Vinyl acetate 50 50 1 100 60-140 05/12/2021 0824 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 126 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ92034-002 Matrix: Aqueous Batch: 92034 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl chloride 50 46 1 92 70-130 05/12/2021 0824 Xylenes (total) 100 100 1 101 70-130 05/12/2021 0824 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 88 70-130 1,2-Dichloroethane-d4 79 70-130 Toluene-d8 88 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 127 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ92056-001 Matrix: Aqueous Batch: 92056 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 05/12/2021 1210 Acrylonitrile ND 1 20 0.80 ug/L 05/12/2021 1210 Benzene ND 1 1.0 0.40 ug/L 05/12/2021 1210 Bromochloromethane ND 1 1.0 0.40 ug/L 05/12/2021 1210 Bromodichloromethane ND 1 1.0 0.40 ug/L 05/12/2021 1210 Bromoform ND 1 1.0 0.40 ug/L 05/12/2021 1210 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 05/12/2021 1210 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/12/2021 1210 Carbon disulfide ND 1 1.0 0.40 ug/L 05/12/2021 1210 Carbon tetrachloride ND 1 1.0 0.40 ug/L 05/12/2021 1210 Chlorobenzene ND 1 1.0 0.40 ug/L 05/12/2021 1210 Chloroethane ND 1 2.0 0.40 ug/L 05/12/2021 1210 Chloroform 0.60 J 1 1.0 0.40 ug/L 05/12/2021 1210 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 05/12/2021 1210 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 05/12/2021 1210 Dibromochloromethane ND 1 1.0 0.40 ug/L 05/12/2021 1210 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 05/12/2021 1210 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 05/12/2021 1210 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 05/12/2021 1210 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/12/2021 1210 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/12/2021 1210 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 05/12/2021 1210 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 05/12/2021 1210 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 05/12/2021 1210 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/12/2021 1210 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/12/2021 1210 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 05/12/2021 1210 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/12/2021 1210 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/12/2021 1210 Ethylbenzene ND 1 1.0 0.40 ug/L 05/12/2021 1210 2-Hexanone ND 1 10 2.0 ug/L 05/12/2021 1210 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/12/2021 1210 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/12/2021 1210 Methylene chloride ND 1 1.0 0.40 ug/L 05/12/2021 1210 Styrene ND 1 1.0 0.41 ug/L 05/12/2021 1210 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/12/2021 1210 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/12/2021 1210 Tetrachloroethene 0.54 J 1 1.0 0.40 ug/L 05/12/2021 1210 Toluene ND 1 1.0 0.40 ug/L 05/12/2021 1210 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 05/12/2021 1210 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 05/12/2021 1210 Trichloroethene ND 1 1.0 0.40 ug/L 05/12/2021 1210 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 05/12/2021 1210 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 05/12/2021 1210 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 128 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ92056-001 Matrix: Aqueous Batch: 92056 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 05/12/2021 1210 Vinyl chloride ND 1 1.0 0.40 ug/L 05/12/2021 1210 Xylenes (total) ND 1 1.0 0.40 ug/L 05/12/2021 1210 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 102 70-130 1,2-Dichloroethane-d4 95 70-130 Toluene-d8 97 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 129 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ92056-002 Matrix: Aqueous Batch: 92056 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 95 1 95 60-140 05/12/2021 0834 Acrylonitrile 100 100 1 104 70-130 05/12/2021 0834 Benzene 50 51 1 102 70-130 05/12/2021 0834 Bromochloromethane 50 51 1 101 70-130 05/12/2021 0834 Bromodichloromethane 50 51 1 103 70-130 05/12/2021 0834 Bromoform 50 45 1 90 70-130 05/12/2021 0834 Bromomethane (Methyl bromide) 50 48 1 95 70-130 05/12/2021 0834 2-Butanone (MEK) 100 98 1 98 70-130 05/12/2021 0834 Carbon disulfide 50 55 1 111 70-130 05/12/2021 0834 Carbon tetrachloride 50 51 1 103 70-130 05/12/2021 0834 Chlorobenzene 50 49 1 99 70-130 05/12/2021 0834 Chloroethane 50 50 1 99 70-130 05/12/2021 0834 Chloroform 50 49 1 99 70-130 05/12/2021 0834 Chloromethane (Methyl chloride) 50 45 1 91 60-140 05/12/2021 0834 1,2-Dibromo-3-chloropropane (DBCP) 50 52 1 104 70-130 05/12/2021 0834 Dibromochloromethane 50 53 1 105 70-130 05/12/2021 0834 1,2-Dibromoethane (EDB) 50 51 1 101 70-130 05/12/2021 0834 Dibromomethane (Methylene bromide) 50 49 1 98 70-130 05/12/2021 0834 trans- 1,4-Dichloro-2-butene 50 46 1 92 70-130 05/12/2021 0834 1,2-Dichlorobenzene 50 50 1 99 70-130 05/12/2021 0834 1,4-Dichlorobenzene 50 48 1 96 70-130 05/12/2021 0834 1,1-Dichloroethane 50 53 1 105 70-130 05/12/2021 0834 1,2-Dichloroethane 50 49 1 99 70-130 05/12/2021 0834 1,1-Dichloroethene 50 53 1 106 70-130 05/12/2021 0834 cis- 1,2-Dichloroethene 50 55 1 111 70-130 05/12/2021 0834 trans- 1,2-Dichloroethene 50 51 1 103 70-130 05/12/2021 0834 1,2-Dichloropropane 50 52 1 104 70-130 05/12/2021 0834 cis- 1,3-Dichloropropene 50 49 1 99 70-130 05/12/2021 0834 trans- 1,3-Dichloropropene 50 48 1 96 70-130 05/12/2021 0834 Ethylbenzene 50 52 1 105 70-130 05/12/2021 0834 2-Hexanone 100 100 1 100 70-130 05/12/2021 0834 Methyl iodide (lodomethane) 50 53 1 106 70-130 05/12/2021 0834 4-Methyl-2-pentanone 100 99 1 99 70-130 05/12/2021 0834 Methylene chloride 50 50 1 101 70-130 05/12/2021 0834 Styrene 50 57 1 113 70-130 05/12/2021 0834 1,1,1,2-Tetrachloroethane 50 53 1 106 70-130 05/12/2021 0834 1,1,2,2-Tetrachloroethane 50 51 1 102 70-130 05/12/2021 0834 Tetrachloroethene 50 54 1 107 70-130 05/12/2021 0834 Toluene 50 53 1 106 70-130 05/12/2021 0834 1,1,1-Trichloroethane 50 53 1 106 70-130 05/12/2021 0834 1,1,2-Trichloroethane 50 51 1 102 70-130 05/12/2021 0834 Trichloroethene 50 50 1 99 70-130 05/12/2021 0834 Trichlorofluoromethane 50 48 1 96 70-130 05/12/2021 0834 1,2,3-Trichloropropane 50 49 1 98 70-130 05/12/2021 0834 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 130 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ92056-002 Matrix: Aqueous Batch: 92056 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 50 1 99 60-140 05/12/2021 0834 Vinyl chloride 50 49 1 98 70-130 05/12/2021 0834 Xylenes (total) 100 110 1 109 70-130 05/12/2021 0834 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 96 70-130 1,2-Dichloroethane-d4 89 70-130 Toluene-d8 94 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 131 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ92125-001 Matrix: Aqueous Batch: 92125 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 05/12/2021 2215 Acrylonitrile ND 1 20 0.80 ug/L 05/12/2021 2215 Benzene ND 1 1.0 0.40 ug/L 05/12/2021 2215 Bromochloromethane ND 1 1.0 0.40 ug/L 05/12/2021 2215 Bromodichloromethane ND 1 1.0 0.40 ug/L 05/12/2021 2215 Bromoform ND 1 1.0 0.40 ug/L 05/12/2021 2215 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 05/12/2021 2215 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/12/2021 2215 Carbon disulfide ND 1 1.0 0.40 ug/L 05/12/2021 2215 Carbon tetrachloride ND 1 1.0 0.40 ug/L 05/12/2021 2215 Chlorobenzene ND 1 1.0 0.40 ug/L 05/12/2021 2215 Chloroethane ND 1 2.0 0.40 ug/L 05/12/2021 2215 Chloroform ND 1 1.0 0.40 ug/L 05/12/2021 2215 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 05/12/2021 2215 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 05/12/2021 2215 Dibromochloromethane ND 1 1.0 0.40 ug/L 05/12/2021 2215 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 05/12/2021 2215 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 05/12/2021 2215 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 05/12/2021 2215 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/12/2021 2215 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/12/2021 2215 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 05/12/2021 2215 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 05/12/2021 2215 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 05/12/2021 2215 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/12/2021 2215 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/12/2021 2215 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 05/12/2021 2215 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/12/2021 2215 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/12/2021 2215 Ethylbenzene ND 1 1.0 0.40 ug/L 05/12/2021 2215 2-Hexanone ND 1 10 2.0 ug/L 05/12/2021 2215 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/12/2021 2215 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/12/2021 2215 Methylene chloride ND 1 1.0 0.40 ug/L 05/12/2021 2215 Styrene ND 1 1.0 0.41 ug/L 05/12/2021 2215 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/12/2021 2215 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/12/2021 2215 Tetrachloroethene ND 1 1.0 0.40 ug/L 05/12/2021 2215 Toluene ND 1 1.0 0.40 ug/L 05/12/2021 2215 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 05/12/2021 2215 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 05/12/2021 2215 Trichloroethene ND 1 1.0 0.40 ug/L 05/12/2021 2215 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 05/12/2021 2215 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 05/12/2021 2215 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 132 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ92125-001 Matrix: Aqueous Batch: 92125 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 05/12/2021 2215 Vinyl chloride ND 1 1.0 0.40 ug/L 05/12/2021 2215 Xylenes (total) ND 1 1.0 0.40 ug/L 05/12/2021 2215 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 92 70-130 Toluene-d8 95 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 133 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ92125-002 Matrix: Aqueous Batch: 92125 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 150 N 1 154 60-140 05/12/2021 2108 Acrylonitrile 100 110 1 110 70-130 05/12/2021 2108 Benzene 50 52 1 105 70-130 05/12/2021 2108 Bromochloromethane 50 54 1 108 70-130 05/12/2021 2108 Bromodichloromethane 50 48 1 96 70-130 05/12/2021 2108 Bromoform 50 48 1 95 70-130 05/12/2021 2108 Bromomethane (Methyl bromide) 50 48 1 97 70-130 05/12/2021 2108 2-Butanone (MEK) 100 130 1 127 70-130 05/12/2021 2108 Carbon disulfide 50 61 1 122 70-130 05/12/2021 2108 Carbon tetrachloride 50 52 1 103 70-130 05/12/2021 2108 Chlorobenzene 50 53 1 105 70-130 05/12/2021 2108 Chloroethane 50 51 1 101 70-130 05/12/2021 2108 Chloroform 50 53 1 106 70-130 05/12/2021 2108 Chloromethane (Methyl chloride) 50 46 1 93 60-140 05/12/2021 2108 1,2-Dibromo-3-chloropropane (DBCP) 50 50 1 99 70-130 05/12/2021 2108 Dibromochloromethane 50 51 1 103 70-130 05/12/2021 2108 1,2-Dibromoethane (EDB) 50 53 1 106 70-130 05/12/2021 2108 Dibromomethane (Methylene bromide) 50 49 1 98 70-130 05/12/2021 2108 trans- 1,4-Dichloro-2-butene 50 27 N 1 54 70-130 05/12/2021 2108 1,2-Dichlorobenzene 50 55 1 110 70-130 05/12/2021 2108 1,4-Dichlorobenzene 50 54 1 107 70-130 05/12/2021 2108 1,1-Dichloroethane 50 52 1 105 70-130 05/12/2021 2108 1,2-Dichloroethane 50 47 1 94 70-130 05/12/2021 2108 1,1-Dichloroethene 50 57 1 114 70-130 05/12/2021 2108 cis- 1,2-Dichloroethene 50 58 1 115 70-130 05/12/2021 2108 trans- 1,2-Dichloroethene 50 55 1 111 70-130 05/12/2021 2108 1,2-Dichloropropane 50 50 1 100 70-130 05/12/2021 2108 cis- 1,3-Dichloropropene 50 51 1 103 70-130 05/12/2021 2108 trans- 1,3-Dichloropropene 50 53 1 106 70-130 05/12/2021 2108 Ethylbenzene 50 55 1 110 70-130 05/12/2021 2108 2-Hexanone 100 100 1 101 70-130 05/12/2021 2108 Methyl iodide (lodomethane) 50 58 1 116 70-130 05/12/2021 2108 4-Methyl-2-pentanone 100 100 1 100 70-130 05/12/2021 2108 Methylene chloride 50 55 1 109 70-130 05/12/2021 2108 Styrene 50 55 1 110 70-130 05/12/2021 2108 1,1,1,2-Tetrachloroethane 50 51 1 102 70-130 05/12/2021 2108 1,1,2,2-Tetrachloroethane 50 52 1 104 70-130 05/12/2021 2108 Tetrachloroethene 50 51 1 102 70-130 05/12/2021 2108 Toluene 50 54 1 108 70-130 05/12/2021 2108 1,1,1-Trichloroethane 50 56 1 113 70-130 05/12/2021 2108 1,1,2-Trichloroethane 50 51 1 103 70-130 05/12/2021 2108 Trichloroethene 50 52 1 104 70-130 05/12/2021 2108 Trichlorofluoromethane 50 45 1 90 70-130 05/12/2021 2108 1,2,3-Trichloropropane 50 50 1 100 70-130 05/12/2021 2108 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 134 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ92125-002 Matrix: Aqueous Batch: 92125 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 56 1 112 60-140 05/12/2021 2108 Vinyl chloride 50 46 1 93 70-130 05/12/2021 2108 Xylenes (total) 100 110 1 108 70-130 05/12/2021 2108 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 93 70-130 1,2-Dichloroethane-d4 81 70-130 Toluene-d8 93 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 135 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ92172-001 Matrix: Aqueous Batch: 92172 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 05/13/2021 1035 Acrylonitrile ND 1 20 0.80 ug/L 05/13/2021 1035 Benzene ND 1 1.0 0.40 ug/L 05/13/2021 1035 Bromochloromethane ND 1 1.0 0.40 ug/L 05/13/2021 1035 Bromodichloromethane ND 1 1.0 0.40 ug/L 05/13/2021 1035 Bromoform ND 1 1.0 0.40 ug/L 05/13/2021 1035 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 05/13/2021 1035 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/13/2021 1035 Carbon disulfide ND 1 1.0 0.40 ug/L 05/13/2021 1035 Carbon tetrachloride ND 1 1.0 0.40 ug/L 05/13/2021 1035 Chlorobenzene ND 1 1.0 0.40 ug/L 05/13/2021 1035 Chloroethane ND 1 2.0 0.40 ug/L 05/13/2021 1035 Chloroform ND 1 1.0 0.40 ug/L 05/13/2021 1035 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 05/13/2021 1035 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 05/13/2021 1035 Dibromochloromethane ND 1 1.0 0.40 ug/L 05/13/2021 1035 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 05/13/2021 1035 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 05/13/2021 1035 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 05/13/2021 1035 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/13/2021 1035 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/13/2021 1035 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 05/13/2021 1035 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 05/13/2021 1035 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 05/13/2021 1035 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/13/2021 1035 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/13/2021 1035 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 05/13/2021 1035 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/13/2021 1035 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/13/2021 1035 Ethylbenzene ND 1 1.0 0.40 ug/L 05/13/2021 1035 2-Hexanone ND 1 10 2.0 ug/L 05/13/2021 1035 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/13/2021 1035 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/13/2021 1035 Methylene chloride ND 1 1.0 0.40 ug/L 05/13/2021 1035 Styrene ND 1 1.0 0.41 ug/L 05/13/2021 1035 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/13/2021 1035 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/13/2021 1035 Tetrachloroethene ND 1 1.0 0.40 ug/L 05/13/2021 1035 Toluene ND 1 1.0 0.40 ug/L 05/13/2021 1035 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 05/13/2021 1035 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 05/13/2021 1035 Trichloroethene ND 1 1.0 0.40 ug/L 05/13/2021 1035 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 05/13/2021 1035 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 05/13/2021 1035 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 136 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ92172-001 Matrix: Aqueous Batch: 92172 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 05/13/2021 1035 Vinyl chloride ND 1 1.0 0.40 ug/L 05/13/2021 1035 Xylenes (total) ND 1 1.0 0.40 ug/L 05/13/2021 1035 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 107 70-130 Toluene-d8 110 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 137 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ92172-002 Matrix: Aqueous Batch: 92172 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 230 N 1 233 60-140 05/13/2021 0933 Acrylonitrile 100 110 1 111 70-130 05/13/2021 0933 Benzene 50 49 1 97 70-130 05/13/2021 0933 Bromochloromethane 50 53 1 107 70-130 05/13/2021 0933 Bromodichloromethane 50 54 1 108 70-130 05/13/2021 0933 Bromoform 50 56 1 113 70-130 05/13/2021 0933 Bromomethane (Methyl bromide) 50 57 1 115 70-130 05/13/2021 0933 2-Butanone (MEK) 100 170 N 1 167 70-130 05/13/2021 0933 Carbon disulfide 50 52 1 104 70-130 05/13/2021 0933 Carbon tetrachloride 50 48 1 97 70-130 05/13/2021 0933 Chlorobenzene 50 49 1 98 70-130 05/13/2021 0933 Chloroethane 50 57 1 114 70-130 05/13/2021 0933 Chloroform 50 50 1 101 70-130 05/13/2021 0933 Chloromethane (Methyl chloride) 50 64 1 129 60-140 05/13/2021 0933 1,2-Dibromo-3-chloropropane (DBCP) 50 57 1 115 70-130 05/13/2021 0933 Dibromochloromethane 50 54 1 109 70-130 05/13/2021 0933 1,2-Dibromoethane (EDB) 50 54 1 108 70-130 05/13/2021 0933 Dibromomethane (Methylene bromide) 50 53 1 107 70-130 05/13/2021 0933 trans- 1,4-Dichloro-2-butene 50 59 1 119 70-130 05/13/2021 0933 1,2-Dichlorobenzene 50 52 1 104 70-130 05/13/2021 0933 1,4-Dichlorobenzene 50 49 1 98 70-130 05/13/2021 0933 1,1-Dichloroethane 50 49 1 98 70-130 05/13/2021 0933 1,2-Dichloroethane 50 51 1 103 70-130 05/13/2021 0933 1,1-Dichloroethene 50 49 1 99 70-130 05/13/2021 0933 cis- 1,2-Dichloroethene 50 51 1 101 70-130 05/13/2021 0933 trans- 1,2-Dichloroethene 50 50 1 101 70-130 05/13/2021 0933 1,2-Dichloropropane 50 53 1 107 70-130 05/13/2021 0933 cis- 1,3-Dichloropropene 50 58 1 116 70-130 05/13/2021 0933 trans- 1,3-Dichloropropene 50 60 1 120 70-130 05/13/2021 0933 Ethylbenzene 50 52 1 105 70-130 05/13/2021 0933 2-Hexanone 100 140 N 1 142 70-130 05/13/2021 0933 Methyl iodide (lodomethane) 50 49 1 98 70-130 05/13/2021 0933 4-Methyl-2-pentanone 100 130 1 128 70-130 05/13/2021 0933 Methylene chloride 50 49 1 99 70-130 05/13/2021 0933 Styrene 50 57 1 114 70-130 05/13/2021 0933 1,1,1,2-Tetrachloroethane 50 50 1 101 70-130 05/13/2021 0933 1,1,2,2-Tetrachloroethane 50 52 1 104 70-130 05/13/2021 0933 Tetrachloroethene 50 49 1 97 70-130 05/13/2021 0933 Toluene 50 52 1 105 70-130 05/13/2021 0933 1,1,1-Trichloroethane 50 49 1 98 70-130 05/13/2021 0933 1,1,2-Trichloroethane 50 53 1 105 70-130 05/13/2021 0933 Trichloroethene 50 48 1 96 70-130 05/13/2021 0933 Trichlorofluoromethane 50 48 1 96 70-130 05/13/2021 0933 1,2,3-Trichloropropane 50 50 1 100 70-130 05/13/2021 0933 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 138 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ92172-002 Matrix: Aqueous Batch: 92172 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 52 1 104 60-140 05/13/2021 0933 Vinyl chloride 50 63 1 125 70-130 05/13/2021 0933 Xylenes (total) 100 110 1 109 70-130 05/13/2021 0933 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 102 70-130 1,2-Dichloroethane-d4 100 70-130 Toluene-d8 103 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 139 of 175 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ92201-001 Matrix: Aqueous Batch: 92201 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Tetrachloroethene ND 1 1.0 0.40 ug/L 05/13/2021 1310 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 108 70-130 1,2-Dichloroethane-d4 92 70-130 Toluene-d8 98 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 140 of 175 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ92201-002 Matrix: Aqueous Batch: 92201 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Tetrachloroethene 50 48 1 96 70-130 05/13/2021 1207 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 101 70-130 1,2-Dichloroethane-d4 95 70-130 Toluene-d8 97 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 141 of 175 ICP-MS Metals - MB Sample ID: WQ90835-001 Matrix: Aqueous Batch: 90835 Prep Method: 3005A Analytical Method: 6020B Prep Date: 05/03/2021 0426 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 05/03/2021 1615 Arsenic ND 1 2.0 1.3 ug/L 05/03/2021 1615 Barium ND 1 5.0 1.3 ug/L 05/03/2021 1615 Beryllium ND 1 0.40 0.15 ug/L 05/03/2021 1615 Cadmium ND 1 0.50 0.13 ug/L 05/03/2021 1615 Chromium ND 1 5.0 1.3 ug/L 05/03/2021 1615 Cobalt ND 1 5.0 1.3 ug/L 05/03/2021 1615 Copper ND 1 5.0 1.3 ug/L 05/03/2021 1615 Lead ND 1 1.0 0.25 ug/L 05/03/2021 1615 Nickel ND 1 5.0 1.3 ug/L 05/03/2021 1615 Selenium ND 1 5.0 1.3 ug/L 05/03/2021 1615 Silver ND 1 1.0 0.25 ug/L 05/03/2021 1615 Thallium ND 1 0.50 0.15 ug/L 05/03/2021 1615 Vanadium ND 1 5.0 2.5 ug/L 05/03/2021 1615 Zinc ND 1 10 2.5 ug/L 05/03/2021 1615 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 142 of 175 ICP-MS Metals - LCS Sample ID: WQ90835-002 Matrix: Aqueous Batch: 90835 Prep Method: 3005A Analytical Method: 6020B Prep Date: 05/03/2021 0426 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 100 1 102 80-120 05/03/2021 1621 Arsenic 100 98 1 98 80-120 05/03/2021 1621 Barium 100 100 1 101 80-120 05/03/2021 1621 Beryllium 100 110 1 114 80-120 05/03/2021 1621 Cadmium 100 94 1 94 80-120 05/03/2021 1621 Chromium 100 96 1 96 80-120 05/03/2021 1621 Cobalt 100 95 1 95 80-120 05/03/2021 1621 Copper 100 99 1 99 80-120 05/03/2021 1621 Lead 100 100 1 103 80-120 05/03/2021 1621 Nickel 100 97 1 97 80-120 05/03/2021 1621 Selenium 100 85 1 85 80-120 05/03/2021 1621 Silver 100 100 1 102 80-120 05/03/2021 1621 Thallium 100 100 1 101 80-120 05/03/2021 1621 Vanadium 100 96 1 96 80-120 05/03/2021 1621 Zinc 100 88 1 88 80-120 05/03/2021 1621 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 143 of 175 ICP-MS Metals - MB Sample ID: WQ90837-001 Matrix: Aqueous Batch: 90837 Prep Method: 3005A Analytical Method: 6020B Prep Date: 05/07/2021 0324 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 05/07/2021 1353 Arsenic ND 1 2.0 1.3 ug/L 05/07/2021 1353 Barium ND 1 5.0 1.3 ug/L 05/07/2021 1353 Beryllium ND 1 0.40 0.15 ug/L 05/07/2021 1353 Cadmium ND 1 0.50 0.13 ug/L 05/07/2021 1353 Chromium ND 1 5.0 1.3 ug/L 05/07/2021 1353 Cobalt ND 1 5.0 1.3 ug/L 05/07/2021 1353 Copper ND 1 5.0 1.3 ug/L 05/07/2021 1353 Lead ND 1 1.0 0.25 ug/L 05/07/2021 1353 Nickel ND 1 5.0 1.3 ug/L 05/07/2021 1353 Selenium ND 1 5.0 1.3 ug/L 05/07/2021 1353 Silver ND 1 1.0 0.25 ug/L 05/07/2021 1353 Thallium ND 1 0.50 0.15 ug/L 05/07/2021 1353 Vanadium ND 1 5.0 2.5 ug/L 05/07/2021 1353 Zinc ND 1 10 2.5 ug/L 05/07/2021 1353 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 144 of 175 ICP-MS Metals - LCS Sample ID: WQ90837-002 Matrix: Aqueous Batch: 90837 Prep Method: 3005A Analytical Method: 6020B Prep Date: 05/07/2021 0324 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 100 1 105 80-120 05/07/2021 1400 Arsenic 100 99 1 99 80-120 05/07/2021 1400 Barium 100 100 1 102 80-120 05/07/2021 1400 Beryllium 100 99 1 99 80-120 05/07/2021 1400 Cadmium 100 97 1 97 80-120 05/07/2021 1400 Chromium 100 100 1 101 80-120 05/07/2021 1400 Cobalt 100 100 1 103 80-120 05/07/2021 1400 Copper 100 110 1 106 80-120 05/07/2021 1400 Lead 100 110 1 106 80-120 05/07/2021 1400 Nickel 100 100 1 102 80-120 05/07/2021 1400 Selenium 100 88 1 88 80-120 05/07/2021 1400 Silver 100 100 1 102 80-120 05/07/2021 1400 Thallium 100 110 1 106 80-120 05/07/2021 1400 Vanadium 100 100 1 102 80-120 05/07/2021 1400 Zinc 100 100 1 101 80-120 05/07/2021 1400 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 145 of 175 ICP-MS Metals - MS Sample ID: WD30017-007MS Matrix: Aqueous Batch: 90837 Prep Method: 3005A Analytical Method: 6020B Prep Date: 05/07/2021 0324 Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony ND 100 110 1 108 75-125 05/07/2021 1415 Arsenic ND 100 85 1 85 75-125 05/07/2021 1415 Barium 220 100 320 1 102 75-125 05/07/2021 1415 Beryllium ND 100 92 1 92 75-125 05/07/2021 1415 Cadmium ND 100 97 1 97 75-125 05/07/2021 1415 Chromium 12 100 100 1 90 75-125 05/07/2021 1415 Cobalt ND 100 85 1 85 75-125 05/07/2021 1415 Copper ND 100 81 1 81 75-125 05/07/2021 1415 Lead 1.2 100 94 1 93 75-125 05/07/2021 1415 Nickel ND 100 81 1 81 75-125 05/07/2021 1415 Selenium ND 100 90 1 90 75-125 05/07/2021 1415 Silver ND 100 88 1 88 75-125 05/07/2021 1415 Thallium ND 100 95 1 95 75-125 05/07/2021 1415 Vanadium ND 100 94 1 94 75-125 05/07/2021 1415 Zinc ND 100 75 1 75 75-125 05/07/2021 1415 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 146 of 175 ICP-MS Metals - MSD Sample ID: WD30017-007MD Matrix: Aqueous Batch: 90837 Prep Method: 3005A Analytical Method: 6020B Prep Date: 05/07/2021 0324 Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Antimony ND 100 110 1 108 0.039 75-125 20 05/07/2021 1422 Arsenic ND 100 86 1 86 1.4 75-125 20 05/07/2021 1422 Barium 220 100 330 1 107 1.5 75-125 20 05/07/2021 1422 Beryllium ND 100 92 1 92 0.081 75-125 20 05/07/2021 1422 Cadmium ND 100 98 1 98 0.71 75-125 20 05/07/2021 1422 Chromium 12 100 100 1 91 0.73 75-125 20 05/07/2021 1422 Cobalt ND 100 86 1 86 1.1 75-125 20 05/07/2021 1422 Copper ND 100 81 1 81 0.16 75-125 20 05/07/2021 1422 Lead 1.2 100 94 1 93 0.23 75-125 20 05/07/2021 1422 Nickel ND 100 81 1 81 0.11 75-125 20 05/07/2021 1422 Selenium ND 100 92 1 92 1.6 75-125 20 05/07/2021 1422 Silver ND 100 89 1 89 1.1 75-125 20 05/07/2021 1422 Thallium ND 100 94 1 94 1.1 75-125 20 05/07/2021 1422 Vanadium ND 100 94 1 94 0.48 75-125 20 05/07/2021 1422 Zinc ND 100 74 N 1 74 0.57 75-125 20 05/07/2021 1422 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 147 of 175 Chain of Custody and Miscellaneous Documents Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 148 of 175 �0 < ro m D ;v :v m v 0) U) m o D CD � r m n O c m 3 Q N co 1 3 CD V C N 0 � CD � V � �C -4� CD V 0 O CD O y T z3 v� x �- o w N Q N O E3 FACE ANALYTiCAL SERMES, LLC C Ar, aiyfi a t06 Varrtagc Point Vdve - Wes! GO;umbia. 9C �!9172 �1 Tr�f�fic�el�Eo. �0.-791-�'i4'� f�aa h�a. #3�3-JA1-9111 %%ww.;?acelabs-yom G7ferrc ��La �Psct ,+4r{��grg &477�fe''Sc � ill,Y h Number J-19 owt* /IrIrS i� ��'Ih h#.r I{lgprs Srn2:Y 14: Y:�.S'.'�1 y Pegg. Wre PC��'kL 1 I aJ Ili j 'C}. M}. Cbr a r.�,,. P • �AiJ�k' Ly.4msa.^+�H'r'g QI {. [Y1Etb�1'_ VI YlPe '+ �1 1� Y.�}` f . � '&!I!lyrlrS�'grC311531" HL`}' r:4 Z — "' �I I 11r �k 1 I 1 1 S -- -- I i• I fr jf��f -1 .tom TurnArour��7meRagay (piTarJa,4�i4vnw ►a�p7lldAPlIFX,}9ddedAi�J Q� paf aC-122h'e+*Wfvoearf.AAA. yr - C3 �enF&rd = h nt ify} lJFWUMTG'idYdEAWuMbY1tb-Hm+l2�'; L'Fkm-nible rAldrlrreant E;Pgkm ❑uAwAr f. L'1M4 J' P Igerzoa t j. P.rfvKrshedlay Y �Rl i�s� a u b �.'�� ?'U � w .. ssl:srwa� a �RI'.ylrpdge dby ay x by ' - as�s T1m9 4. iatarsk,ryrcri.gedb Mots Ag wilples am m,&ryed ,fir tur tall "C ONLI, A MleSS(3JWFiif'€fi7C$mo.M6an�no,*. FfeeeJrur�cn,ce([xctek 1b rcrpacN rO:.;d4rTr:lp� TRi +TAah: 6t7�'Tw & YF�LOW,AvWn fo Oafw•Mrry v4p Sarp;o%� P2iwi+, 1c!Fff Ggsy VVD300'17 Rsrrra'�a JL'¢o.'4• f,L'. ❑:..cxmre.�rit fkrr�gf,�+Fpy n m D D n r VTI [A�7 m cn r 0 PACE ANALYTICAL SERVICES, LLC 5arnpim Rece I�r[ Cherkllst (SRq (MOmItIC-15) faccArkrly .V' IssuinhAul#iurity: Par'Lp FNV- WCOL aFriple ReeeipI heckfiSt ( FAQ CItCn,. 1iLL Cooler InR -tecl l,yidEirr.; alp{O *4 3tb2.D21 WMQDt7 PK4vK]nsafrac ipt; , Pace Clicn# 1!.- FudEx Uther. s ,e No l_ �Ncre f7rbLs�fi} =gals rest:nt an the r:ooJel' — Nu , iNA 2. Ifcuswa seals x4ca resent*wcxetlj° i� me iftnd unhrvken? Stri ILi: 20.'1E2 P 111ari:ieStrip IC7: *+ Tceied hy-_RU2 OriginaJ t MP.- ICEu a upon receipt J Derived (Cc irrceted) fomperr MM Lptul receipt %';Ol it 5iiap-Crap J O.- 4.2 14.7. J lice HA } rxA uC! A f NA GC — Method: ©-FemperaliimBlarik [�irsat 13o[tles IRGm ID- 6 LRGun Couection l+ac#ar: U � k1clhod oFowlprt: � Wet Tee ❑ IuV Pucica ❑ Ice 1+Jane �] Y�MO . . If telnl,eriFilm Of any cooler bxcctrded 6.0°�� fwa� Project ll�rrag4r Noti flCd ' PM w� Kotified hy, phone f &,nail r Pic tr -Lv-face (6-deLJ oiie], 1'es4. Js slip corgmcrcJ a: r rx!ricr' { king slip attached to this foam g f Yes 3, Were v.apercusmclypror��xJure&(re [inquishe&ruzeived)followed? 6. Wem sxritp!e lUs listed on the COC9 7, Were samp[c IDs lisicd ❑R aJI mill' cDntaimrsf Yes -N" R_ Was oo;lECOV a date 8t t;me lisird on [he COC'i Yes No 9, Was colle-; irjn date & tI Ine listr:d 1- all simple cenmillcrs- ,� Yes ❑ Ne IU_ Did �dI container label infirimalion (ID, aaec. tame) ogee with lihe CC1C Yex Nu 11_ Wei--- teals uF W- pertgmr d fisted of the COC? ❑ Yes ❑fir, 12• Did aJ[ sompics [L-rivc izl the propar cor.Eah4;rs fur each test Etnd�or in gDcd UO.-KIRiori (Uatrrol , [ids on, cif:.)? _ des No 13. was a.Jrc{uate sample volt�rne availahm? Y'o No 14. Were All sall pl-s received within :i hum, wh icha�ver cx,ri Ies i YGs. r "u �5. CI a any sample-5 containerg�^;r x Circla ori�;) sain les Not Iistud an COC' [:1 Yw V]No DNA 16. Parr VOA ant! KKK-175 u3�ip�c�w�r� 13b7es presEsn[:} °raa size" (-/:'or6ytm in di in any ❑f Ch a VOA via Is? V. Ya-q Nu NA I?, Were all 1}IWVrnc'ta[sr'rtutrient samples received at a pH e< 2? — YRMS M1 J NA I.N. Wem aR cva_iidj, salllf;[M reeeived at a pH > 12 and sulfudie tan 1ae rexe[ved at a P14 11 YCS ❑N-u LZINA 79. Wereall upplir:ablc 1�lH3iT[, ,cyanidaphenEa 52 .1}[,138 ' {: 4.5in +I. samp[rs free _ rasiJuaI chWi.m? ❑VSS ❑No CNA 20_ Were clieiri iemaresfrc� rsls{i_c. requested dilutiang, M IMSa dcsi#tiatiom, L-IC_,-) -Correctly transcribed ti-om t m C,OC Jt1[o the COMMen' SOCLion in T, MS? •'es 1 21. will a thti lucre 11umbw listed an t}re t:antairrer Jebel? If � C t1o0a Y Wn Slim pip 1'rcition (l4fust be o0lripEcted Forarsy srenple(s) irrcai�lect[y preserv�dfn with aeadpu;�e.) Sarrslyle(s} # Pica receivM incorrectly preserved a n�i were adjust& ! acca insan,ple receiving w:[h �'� tnL at circle r3F ie: �H2S, ffN{].3, HC[, 2VrrC7t1 using SR ,i~ "A _ Tinsc tti p 5Glvaii 11 iI"mare then cnle prewrvativo is needed pleath se nDte in e oaltyrronts below. Samples] NA noceivadwith bubbles �-6 Inm in dianye amPTs(s) xa ware mwl'ved with TRC > U nigfL OF A! 19 is Irv) and wC adjiil.;lcr[ acw:d irigty in sample 1 cceiving witJ, sadirrn lhrosurfWG (Na. S%G,) wdh Shealy Ili_ KA 5R barcede -nbals applicd by: 1110 � � it r c � + 11� [•v- � � � f ~ �� 9', C'at,e 1 of 1 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 150 of 175 �0 <CD m D v :v CD C - 0 °� rn m v� o m N � r r N C) o O � C N 3 Q m y 1 3 n a) V C N 0 O W CDo� V � CD rn -4� V 0 O CD O y b =v X 0 E3 A PAGE ANALYTICAL SERVICES, LLC (,�#1{� j l 106 Va'ltarA Point Drive • WootColJmbia, SC 29172 Telcpbuke No, 803-7SI-9700 FdX No. 1±0Ci-791-9111 www, panel ahe6_co 71 Yens wart 17 txt' Ad ngas c4vy drSP k G'sCA _ pA I F7L�f67.49�71e 1 1!l.LStr# 4r �aiektfi'hb uJ l�'}}r�LTto.dkvl I{,;r,,U 7rm -0.¢k Ti be arTP-d W Ac Ai no6 £¢ y nr ��es�LRLr Y � - llu - 4 j I .2.9• 21 ��1J I.0 � •�,�� r! I. V LPG y It —2 0130 x ( . �1 . �,..s - lam- d .. Tam Arcwyo T"d Raquir d fPV& 64 awmmlyaw&edw tvcd+7a d 7A 4 —re-rMw,"ej Y, F?a 141qur�Ae¢ } a-?o F Re�ir,�rr'�r,e79y or.J^. a Tdc-M i �r avr !2_.b T . fiefGlren;hr:dby Data Tam: {tii0Q9_' W san +�s are refahyd ,Ylr tga!jr weeks f�orrT re DNS ?vier arrargemwnts are m_ P90VAMMOM 3,MrE 3 'rEUOW-H-3 rrr 0 v.&h Sawv *(s), Pldi -F,,V_ .r Ce py �1. 15lif Plumber 119913 T9k%%WrW M:L e'H-r; wH .4r�rF;b (4 haL1J A�at a 1Yx:�e� .+(��.k�P '9 fI4EtYEd� I M 33 1 1-I 1 T51 1 ti l 1 1 Z x 4131 t Fc�4s� F�,rt� ,�derthR:aliovx .7119nn-HP7�rd U hkrnmH* p S's'n Irrilanl 7 P[ow. ❑ 4ilY0am P_ Ra,:au%iby z, Rnmed pry �JOdR �R_ Al 1"1 d�2- WD30017 LM oc P0007Merus ppxoy) Dive 7aoa Dwe TOM _ I La�grYalveyreaer dt Mao V-9 LSE LkY � — °M9I4L^6'QD i'Y ( Na Lv a:r * r7aae�r,�f 70-y. �0 CD m D vv m 0 rn �CD o D CD � r r N_ 0 o o � c m 3 Q �c m y 1 3 CD V C N 0 W CDo� V � CD �C -4� V 0 O oCDaq b Iv E3 PACE ANALYTICAL SERVICES, LLC 106 "rlace Point [xim �vda. [col,:tibia, SC 29i72 Telephone' , 803-791-9700 Fax Na. iCCi 91.9j"7 VAMPOO$1abs.com Repsrr ra car,t:l ---------------- J�drYfY-� 3 5�l.ili Lti. ''tA!C Zp 4xm ]r a C- P+i,, rrd ,VAIF76 r EIclosed J-r welB _ jOwA iCar N0. Sanwa !d l+7s�criFil wM A raacJp 6awlk AV bs Goujr av rnelYAJ ?AVI— - —160 �i Ii1C. ` 1.1iVrx .�rY Gb�hk'r+eFs F, F � lU t RT dY �rC'S�74f'e1P �� GiY 3o4r� C't{k:r4� TA909 0116AX II llUn A7 MLF7?MtL A*gWi?adjFm!a& W.,62SO ff.yWM&r aWamrr 4qF� •y .45D gdl n 57arrd wd F. 14u Spocffv, F 'LL%rrrfe4U d W 7 t*Mi� vfo V r, FicS[i•trfulsFa7by // OAS � 4 . tl'9MQ4hi. i by d8 I AYIC' a' 'ga5"by Dare TPna A by a7sur 7Eae NOfe: AN s4rpJes arig miaLgod for friar wr-e frori re, -Bo Z+7 ss Odw er7sngerneritr' are nest,. 1USM'arm2Y. MOTH h YFLLGVl-Rahun ro qb, rL r" %VM a1er. *(s,: P,W Fi or q,Farr kpy 7c�W.onea Na- I G'T&7ff Number i .-° 1 4 oxre A1c. :q Yay pf WD300 V flemsfir� {.^.cokr'.D. r`.ss'1eNazsrff&dwMLmfibo �GRage,�r�rraNs(•Sb+ lJ ❑ Non•Hnad n fla'ollwbic I, +Ff.l 1. aard . I PD'!Od ❑ UAIDL A 0. T'Pc�rt7by 2. &M:h'ad by Mr. ,rr11tl 4.1.5'bWdki'yf5�lfl�- �— r# 7R716 TMWW ti' O7s1!_Y - f 7 tp�+ •' + awvf Y I' I N �3eC.7�d or] �r% ec. .Vc Aca .�'ee+e Ar. pr 7 r9 D C r+nc{In5rirlJ'JY71ta�: di'f',�iN2�C; n m Z D n D r m 0 m cn r 0 PACE ANALYTICAL SERVICES, LLC Samples Receipt CheGUSllt {SRC) (MLODIRC-15) '3 .4rAVyVw(' IssuingAu'horlty_ PMV ENV_ WOOL Ample receipt Checkii t (S R�Cooi", CaltnC BI'F _ iurpcctarl ky1�a[c: _RC2 { 0+413U1-.o21 L4X $. WLTRID17 erccoipt� � Pace C']Vdcn custDdy seals shchht nn iFrs coolersu rn � NA 2, lf-custntivseals �n�7c wgem,wea-e 1h y intactard unbroken? p ID; ` i'� Chl;rinc %t 13, 2r.3e� Tegte({ by_ aRit2 rgnal tensperatura LLpttn mreipt,' ilxh{ 1 (CrkTrocled,' 14mpePa r& upon M� -ipt 'MOM Snap -Cup iD- NA CC 2.4 }2.4 a�+ 2.S f? ry rC 2.7 1 2.7 f Bdivil; ❑Te17pentare 13ha ins# i3ot[l Ili iUYJ 11): 6 1Tt GAL)CD7t!dion Factor: 0 Method of cusrizmt: ❑� ❑det Ice Ela, P�lC5 1 .J Dr Icc ❑ None QYes LNo VONA�_ lft'utperOureOriff' cooler exLrG!ledb.U"U.Waserojccthiana '-NO'ilwQ+[I? T3ht W&S T4U=fried]: Iltione fert]Rili !aC@-t'sceCJL'Cli 8]]s'. yes1n + 7Q14 is the ctrmrll Cial a4ttrler'a packing sl attaci:cd i tlti`g fprm? Ye* �ln 5. Wrrc proper c,astady pr�dures (nsl'suqui LexlFrr�r vet folCrnvesl? Yes No 6, )AAIPM =] ie TD8 1isted nn the C()C? d Yes O No 7, Wnrt:.;ample 11�3 113ted [m all Sairlplc collminc s? f Yes _ i�To b- W� onl lectiOn date time listed on the CC)C . Ye; lti9 9, WAS oglleCtiun ram � Ilene llsxd On ail 3an1j}1c Cui3Grrrrs" J Yt!, [� No '0. JD; l HIJ ooaltpincr lalsel :riformatior[ (Ib, dolt, lima) a ruw with 1}tv C0 7 J 'es ]c, ] 1 _ W= tars 10 Lie }herformud 11.�1er1 rm tho COC"' Imo, I}id slf �Hmpir an'i4e in tnc proper c�oTuai:ters fo, ems, kst nntffnr in Sri Yes L.-II No goad cantitoan (unbrakcn, lids nn, Oro. _ Ycs h o 13. Was a,dcquate sanhpie vol nmc. ava iable? Yes , Na 14. Wcrc ail sarlMlf�g IW6VCd wilhirt'h the bolding time or 48 hours, ;yhj wyer wracs Y: S ' l 15_ Were imy satn lc%5 containers mi Nit 'excess (circle rtrnc) 3ampk* Not l iS" au COC E] ❑ No N. ]b. For VOA and HSK-175 sa nphn, were buhlrles prc3errt "peas izc" (W'or 4nhm in di in aln oftlse VOA "ials? No NA 17_ Were all samples Trxoiveda,apHnP��'� Yes No NA l S. Wr.-e all cytunide slum les reoid vcd at ;a pH > 12 and sul tide sarrkpies rooeivcd at a F H ❑, Yes ❑ N43 R. k4'rru all angyhca to ;�f3{1 11ty�ulule;phcnol!t57. , , s:rni,lcs free Y L,� i❑ No .N.4 . CrG cliertL remarkslrequests {t.e, reiltiMed dilutions, Malm9D drsigratiortE, eie_..l corr2dly tFM1t -ibed from tlhe t_ M into the co:n1Trenl seLxiorh in LJKS? Yos i No 1_ Was :he ttntC nuDkWF fished On t'Lte oop:Fainer Iabc . if vzs, un[r. 4 21369 iarflipli: Fraser, K#ian (R7ust br carnple44xl feu' 8ry �alltpie(s) jT3CDM ctly p3wim tad c,r with Peod.space_) temple{ j ^ were rcccived itlow'I'vAly rzewrved and Were adjustod acci i sample rccci%ing with KA .. —ill i, Pf cimle unc. i-l2SO4, [ 1 3,1iCi,1TaQH irSln SR # 1tiA -rne of preservallbrh �A 1 P morn ban Dno preservm iva is nMded, p base hbOW in the conhnhe rls belaw. arrpic(s NA _wcrrstiOtiVedhWi ltbubhlas>Cr men indiame umplen(L;) Ph were reocivcd w;lh T14C [�.S m 1L (lf l9 is r�0) dnd wi *5'M dirgly i:n smiplc receiving wi:h aodimn thiosullfau� (NR2s203) wit}t Sheaiy 1D: MA Jt bijivu& Jabe.16 applied bg' C;on,ramtm , DatL- L'WC,"103 t 9% Page i of 1 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 153 of 175 aceAna lytical LELAP CERTIFICATE NUMBER: 01955 DOD-ELAP ACCREDITATION NUMBER: 74960 ANALYTICAL RESULTS PERFORMED BY Pace Analytical Gulf Coast 7979 Innovation Park Dr. Baton Rouge, LA 70820 (225) 769-4900 Report Date 05/18/2021 Report Y 211050509 �1��i �1��i �1��i �1��i �1��i �1��i �1��i �1��i �1��i III Project WD30017 Closed Buncombe Wells Deliver To Lucas Odom Pace Analytical Services South Carolina 106 Vantage Point Drive West Columbia, SC 29172 803 791 9700 L* PJLA wAting WD ELAP Additional Recipients NONE ISO 17025 Pace Gulf Coast Report#: 221050509 Page 1 of 22 Page 154 of 175 Report#: 221050509 aceAnarytical Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Laboratory Endorsement Sample analysis was performed in accordance with approved methodologies provided by the Environmental Protection Agency or other recognized agencies. The samples and their corresponding extracts will be maintained for a period of 30 days unless otherwise arranged. Following this retention period the samples will be disposed in accordance with Pace Gulf Coast's Standard Operating Procedures. Common Abbreviations that may be Utilized in this Report ND Indicates the result was Not Detected at the specified reporting limit NO Indicates the sample did not ignite when preliminary test performed for EPA Method 1030 DO Indicates the result was Diluted Out MI Indicates the result was subject to Matrix Interference TNTC Indicates the result was Too Numerous To Count SUBC Indicates the analysis was Sub -Contracted FLD Indicates the analysis was performed in the Field DL Detection Limit LOD Limit of Detection LOQ Limit of Quantitation RE Re -analysis CF HPLC or GC Confirmation 00:01 Reported as a time equivalent to 12:00 AM Reporting Flags that may be Utilized in this Report J or I Indicates the result is between the MDL and LOQ J DOD flag on analyte in the parent sample for MS/MSD outside acceptance criteria U Indicates the compound was analyzed for but not detected B or V Indicates the analyte was detected in the associated Method Blank Q Indicates a non -compliant QC Result (See Q Flag Application Report) " Indicates a non -compliant or not applicable QC recovery or RPD — see narrative E Organics - The result is estimated because it exceeded the instrument calibration range E Metals - % diference for the serial dilution is > 10% L Reporting Limits adjusted to meet risk -based limit. P RPD between primary and confirmation result is greater than 40 DL Diluted analysis — when appended to Client Sample ID Sample receipt at Pace Gulf Coast is documented through the attached chain of custody. In accordance with NELAC, this report shall be reproduced only in full and with the written permission of Pace Gulf Coast. The results contained within this report relate only to the samples reported. The documented results are presented within this report. This report pertains only to the samples listed in the Report Sample Summary and should be retained as a permanent record thereof. The results contained within this report are intended for the use of the client. Any unauthorized use of the information contained in this report is prohibited. I certify that this data package is in compliance with The NELAC Institute (TNI) Standard 2009 and terms and conditions of the contract and Statement of Work both technically and for completeness, for other than the conditions in the case narrative. Release of the data contained in this hardcopy data package and in the computer readable data submitted has been authorized by the Quality Assurance Manager or his/her designee, as verified by the following signature. Estimated uncertainty of measurement is available upon request. This report is in compliance with the DOD QSM as specified in the contract if applicable. Authorized Signature Pace Gulf Coast Report 221050509 Pace Gulf Coast Report#: 221050509 Page 2 of 22 Page 155 of 175 1 _21Analytical Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Certifications Certification Certification Number DOD ELAP 74960 Alabama 01955 Arkansas 88-0655 Colorado 01955 Delaware 01955 Florida E87854 Georgia 01955 Hawaii 01955 Idaho 01955 Illinois 200048 Indiana 01955 Kansas E-10354 Kentucky 95 Louisiana 01955 Maryland 01955 Massachusetts 01955 Michigan 01955 Mississippi 01955 Missouri 01955 Montana N/A Nebraska 01955 New Mexico 01955 North Carolina 618 North Dakota R-195 Oklahoma 9403 South Carolina 73006001 South Dakota 01955 Tennessee 01955 Texas T104704178 Vermont 01955 Virginia 460215 Washington C929 USDA Soil Permit P330-16-00234 Pace Gulf Coast Report#: 221050509 Page 3 of 22 Page 156 of 175 Report#: 221050509 aceAnarytical Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Case Narrative Client: Pace Analytical Services South Carolina Report: 221050509 Pace Analytical Gulf Coast received and analyzed the sample(s) listed on the Report Sample Summary page of this report. Receipt of the sample(s) is documented by the attached chain of custody. This applies only to the sample(s) listed in this report. No sample integrity or quality control exceptions were identified unless noted below. No anomalies were found for the analyzed sample(s). Pace Gulf Coast Report#: 221050509 Page 4 of 22 Page 157 of 175 aceAnarytical Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Sample Summary LAB ID Client ID Matrix Collect Date Receive Date 22105050901 MW-2 Water 04/29/202110:00 05/04/2021 10:21 22105050902 MW-4 Water 04/29/202114:10 05/04/2021 10:21 22105050903 MW-6 Water 04/29/202112:05 05/04/2021 10:21 22105050904 MW-13-132 Water 04/29/202113:55 05/04/2021 10:21 22105050905 MW-18-78 Water 04/29/202110:10 05/04/2021 10:21 22105050906 MW-19-75 Water 04/29/202111:45 05/04/2021 10:21 22105050907 MW-19-110 Water 04/29/202113:10 05/04/2021 10:21 22105050908 MW-21-21 Water 04/29/202112:20 05/04/2021 10:21 22105050909 MW-21-94 Water 04/29/202110:45 05/04/2021 10:21 22105050910 MW-24-160 Water 04/29/202116:45 05/04/2021 10:21 22105050911 MW-2 (1-12) Bubble Strip 04/29/2021 10:00 05/04/2021 10:21 22105050912 MW-4 (1-12) Bubble Strip 04/29/2021 14:10 05/04/2021 10:21 22105050913 MW-6 (1-12) Bubble Strip 04/29/2021 12:05 05/04/2021 10:21 22105050914 MW-13-132 (H2) Bubble Strip 04/29/2021 13:55 05/04/2021 10:21 22105050915 MW-18-78 (1-12) Bubble Strip 04/29/2021 10:10 05/04/2021 10:21 22105050916 MW-19-75 (1-12) Bubble Strip 04/29/2021 11:45 05/04/2021 10:21 22105050917 MW-19-110 (1-12) Bubble Strip 04/29/2021 13:10 05/04/2021 10:21 22105050918 MW-21-21 (1-12) Bubble Strip 04/29/2021 12:20 05/04/2021 10:21 22105050919 MW-21-94 (1-12) Bubble Strip 04/29/2021 10:45 05/04/2021 10:21 22105050920 MW-24-160 (1-12) Bubble Strip 04/29/2021 16:45 05/04/2021 10:21 Pace Gulf Coast Report#: 221050509 Page 5 of 22 Page 158 of 175 aceAnarytical Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Detect Summary LAB ID Client ID Method Parameter Result Units 22105050901 MW-2 AM23G Acetic Acid 0.37J mg/L 22105050901 MW-2 AM23G Formic Acid 4.6 mg/L 22105050901 MW-2 AM20GAX Ethane 1.2 ug/L 22105050901 MW-2 AM20GAX Ethene 31 ug/L 22105050901 MW-2 AM20GAX Methane 5200 ug/L 22105050901 MW-2 EPA RSK-175 Carbon Dioxide 17300 ug/L 22105050902 MW-4 AM23G Acetic Acid 0.66J mg/L 22105050902 MW-4 AM23G Butyric Acid 0.15J mg/L 22105050902 MW-4 AM23G Formic Acid 10 mg/L 22105050902 MW-4 AM20GAX Methane 3.6J ug/L 22105050902 MW-4 EPA RSK-175 Carbon Dioxide 162000 ug/L 22105050903 MW-6 AM23G Acetic Acid 2.7J mg/L 22105050903 MW-6 AM23G Formic Acid 52 mg/L 22105050903 MW-6 AM20GAX Ethane 0.20J ug/L 22105050903 MW-6 AM20GAX Methane 680 ug/L 22105050903 MW-6 EPA RSK-175 Carbon Dioxide 179000 ug/L 22105050904 MW-13-132 AM23G Acetic Acid 2.7J mg/L 22105050904 MW-13-132 AM23G Formic Acid 48 mg/L 22105050904 MW-13-132 AM20GAX Ethane 0.79J ug/L 22105050904 MW-13-132 AM20GAX Ethene 0.29J ug/L 22105050904 MW-13-132 AM20GAX Methane 3500 ug/L 22105050904 MW-13-132 EPA RSK-175 Carbon Dioxide 15800 ug/L 22105050905 MW-18-78 AM23G Acetic Acid 2.9J mg/L 22105050905 MW-18-78 AM23G Formic Acid 45 mg/L 22105050905 MW-18-78 AM20GAX Ethene 0.70J ug/L 22105050905 MW-18-78 AM20GAX Methane 450 ug/L 22105050905 MW-18-78 EPA RSK-175 Carbon Dioxide 121000 ug/L 22105050906 MW-19-75 AM23G Acetic Acid 2.6J mg/L 22105050906 MW-19-75 AM23G Formic Acid 53 mg/L 22105050906 MW-19-75 AM20GAX Ethane 0.62J ug/L 22105050906 MW-19-75 AM20GAX Methane 1400 ug/L 22105050906 MW-19-75 EPA RSK-175 Carbon Dioxide 94400 ug/L 22105050907 MW-19-110 AM23G Acetic Acid 0.52J mg/L 22105050907 MW-19-110 AM23G Formic Acid 12 mg/L 22105050907 MW-19-110 AM20GAX Ethane 0.18J ug/L 22105050907 MW-19-110 AM20GAX Methane 170 ug/L 22105050907 MW-19-110 EPA RSK-175 Carbon Dioxide 3840 ug/L 22105050908 MW-21-21 AM23G Acetic Acid 3.8J mg/L 22105050908 MW-21-21 AM23G Formic Acid 47 mg/L 22105050908 MW-21-21 AM20GAX Ethane 0.32J ug/L 22105050908 MW-21-21 AM20GAX Ethene 0.46J ug/L 22105050908 MW-21-21 AM20GAX Methane 2200 ug/L 22105050908 MW-21-21 EPA RSK-175 Carbon Dioxide 341000 ug/L 22105050909 MW-21-94 AM23G Acetic Acid 2AJ mg/L Pace Gulf Coast Report#: 221050509 Page 6 of 22 Page 159 of 175 aceAnarytical Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Detect Summary (Continued) LAB ID Client ID Method Parameter Result Units 22105050909 MW-21-94 AM23G Formic Acid 49 mg/L 22105050909 MW-21-94 AM20GAX Ethane 0.75J ug/L 22105050909 MW-21-94 AM20GAX Ethene 0.28J ug/L 22105050909 MW-21-94 AM20GAX Methane 2000 ug/L 22105050909 MW-21-94 EPA RSK-175 Carbon Dioxide 77100 ug/L 22105050910 MW-24-160 AM23G Acetic Acid 0.27J mg/L 22105050910 MW-24-160 AM23G Formic Acid 5.3 mg/L 22105050910 MW-24-160 AM20GAX Ethene 0.36J ug/L 22105050910 MW-24-160 AM20GAX Methane 35 ug/L 22105050910 MW-24-160 EPA RSK-175 Carbon Dioxide 1360 ug/L 22105050911 MW-2 (H2) AM20GAX Hydrogen 120 nM 22105050912 MW-4 (H2) AM20GAX Hydrogen 0.76J nM 22105050913 MW-6 (H2) AM20GAX Hydrogen 22 nM 22105050914 MW-13-132 (H2) AM20GAX Hydrogen 20 nM 22105050916 MW-19-75 (H2) AM20GAX Hydrogen 0.95J nM 22105050917 MW-19-110 (H2) AM20GAX Hydrogen 3.4 nM 22105050918 MW-21-21 (H2) AM20GAX Hydrogen 8.4 nM 22105050919 MW-21-94 (H2) AM20GAX Hydrogen 17 nM 22105050920 MW-24-160 (H2) AM20GAX Hydrogen 4.2 nM Pace Gulf Coast Report#: 221050509 Page 7 of 22 Page 160 of 175 Report#: 221050509 10;aceAr�alytrca! Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Sample Results Collect Date 04/29/2021 10:00 LAB ID 22105050901 M W-2 Receive Date 05/04/2021 10:21 Matrix Water EPA RSK-175 Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 5 05/13/202110:14 BMR 711077 CAS# Parameter Result DL LOQ Units 124-38-9 Carbon Dioxide 17300 635 4500 ug/L AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/08/202117:01 MOS 710558 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.37J 0.12 0.50 mg/L 107-92-6 Butyric Acid 0.058U 0.058 0.50 mg/L 64-18-6 Formic Acid 4.6 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.058U 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.056U 0.056 0.50 mg/L 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.053U 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.056U 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.053U 0.053 0.50 mg/L 127-17-3 Pyruvic Acid 0.060U 0.060 0.50 mg/L AM20GAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/11/202111:21 JCK2 710674 CAS# Parameter Result DL LOQ Units 74-84-0 Ethane 1.2 0.075 1.0 ug/L 74-85-1 Ethene 31 0.12 1.0 ug/L 74-82-8 Methane 5200 2.5 5.0 ug/L Collect Date 04/29/2021 14:10 LAB ID 22105050902 M W-4 Receive Date 05/04/2021 10:21 Matrix Water EPA RSK-175 Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 20 05/13/202110:24 BMR 711077 CAS# Parameter Result DL LOQ Units 124-38-9 Carbon Dioxide 162000 2540 18000 ug/L AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 2 05/08/202117:54 MOS 710558 CAS# Parameter 64-19-7 Acetic Acid 107-92-6 Butyric Acid Result DL LOQ Units 0.66J 0.25 1.0 mg/L 0.15J 0.12 1.0 mg/L Pace Gulf Coast Report#: 221050509 Page 8 of 22 Page 161 of 175 aceAnalytica! Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Sample Results Collect Date 04/29/2021 14:10 LAB ID 22105050902 M W-4 Receive Date 05/04/2021 10:21 Matrix Water AM23G (Continued) Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 2 05/08/202117:54 MOS 710558 CAS# Parameter Result DL LOQ Units 64-18-6 Formic Acid 10 0.11 1.0 mg/L 142-62-1 Hexanoic Acid 0.12U 0.12 1.0 mg/L 646-07-1 i-Hexanoic Acid 0.11 U 0.11 1.0 mg/L 503-74-2 i-Pentanoic Acid 0.12U 0.12 1.0 mg/L 50-21-5 Lactic Acid 0.11 U 0.11 1.0 mg/L 109-52-4 Pentanoic Acid 0.11 U 0.11 1.0 mg/L 79-09-4 Propionic Acid 0.11 U 0.11 1.0 mg/L 127-17-3 Pyruvic Acid 0.12U 0.12 1.0 mg/L AM20GAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/11/202111:32 JCK2 710674 CAS# Parameter Result DL LOQ Units 74-84-0 Ethane 0.075U 0.075 1.0 ug/L 74-85-1 Ethene 0.12U 0.12 1.0 ug/L 74-82-8 Methane 3.6J 2.5 5.0 ug/L Collect Date 04/29/2021 12:05 LAB ID 22105050903 MW-6 Receive Date 05/04/2021 10:21 Matrix Water EPA RSK-175 Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 20 05/13/202110:36 BMR 711077 CAS# Parameter Result DL LOQ Units 124-38-9 Carbon Dioxide 179000 2540 18000 ug/L AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 10 05/08/202118:47 MOS 710558 CAS# Parameter 64-19-7 Acetic Acid 107-92-6 Butyric Acid 64-18-6 Formic Acid 142-62-1 Hexanoic Acid 646-07-1 i-Hexanoic Acid 503-74-2 i-Pentanoic Acid 50-21-5 Lactic Acid 109-52-4 Pentanoic Acid 79-09-4 Propionic Acid 127-17-3 Pyruvic Acid Result DL LOQ Units 2.7J 1.2 5.0 mg/L 0.58U 0.58 5.0 mg/L 52 0.55 5.0 mg/L 0.58U 0.58 5.0 mg/L 0.56U 0.56 5.0 mg/L 0.61 U 0.61 5.0 mg/L 0.53U 0.53 5.0 mg/L 0.56U 0.56 5.0 mg/L 0.53U 0.53 5.0 mg/L 0.60U 0.60 5.0 mg/L Pace Gulf Coast Report#: 221050509 Page 9 of 22 Page 162 of 175 aceAnalytica! Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Sample Results Collect Date 04/29/2021 12:05 LAB ID 22105050903 MW-6 Receive Date 05/04/2021 10:21 Matrix Water AM20GAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/11/202111:44 JCK2 710674 CAS# Parameter Result DL LOQ Units 74-84-0 Ethane 0.20J 0.075 1.0 ug/L 74-85-1 Ethene 0.12U 0.12 1.0 ug/L 74-82-8 Methane 680 2.5 5.0 ug/L Collect Date 04/29/2021 13:55 LAB ID 22105050904 MW-13-132 Receive Date 05/04/2021 10:21 Matrix Water EPA RSK-175 Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 5 05/13/202110:46 BMR 711077 CAS# Parameter Result DL LOQ Units 124-38-9 Carbon Dioxide 15800 635 4500 ug/L AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 10 05/08/202119:41 MOS 710558 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 2.7J 1.2 5.0 mg/L 107-92-6 Butyric Acid 0.58U 0.58 5.0 mg/L 64-18-6 Formic Acid 48 0.55 5.0 mg/L 142-62-1 Hexanoic Acid 0.58U 0.58 5.0 mg/L 646-07-1 i-Hexanoic Acid 0.56U 0.56 5.0 mg/L 503-74-2 i-Pentanoic Acid 0.61 U 0.61 5.0 mg/L 50-21-5 Lactic Acid 0.53U 0.53 5.0 mg/L 109-52-4 Pentanoic Acid 0.56U 0.56 5.0 mg/L 79-09-4 Propionic Acid 0.53U 0.53 5.0 mg/L 127-17-3 Pyruvic Acid 0.60U 0.60 5.0 mg/L AM20GAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/11/202111:55 JCK2 710674 CAS# Parameter 74-84-0 Ethane 74-85-1 Ethene 74-82-8 Methane Result DL LOQ Units 0.79J 0.075 1.0 ug/L 0.29J 0.12 1.0 ug/L 3500 2.5 5.0 ug/L Pace Gulf Coast Report#: 221050509 Page 10 of 22 Page 163 of 175 aceAnalytica! Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Sample Results Collect Date 04/29/2021 10:10 LAB ID 22105050905 MW-18-78 Receive Date 05/04/2021 10:21 Matrix Water EPA RSK-175 Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 20 05/13/202110:52 BMR 711077 CAS# Parameter Result DL LOQ Units 124-38-9 Carbon Dioxide 121000 2540 18000 ug/L AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 10 05/08/202122:21 MOS 710558 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 2.9J 1.2 5.0 mg/L 107-92-6 Butyric Acid 0.58U 0.58 5.0 mg/L 64-18-6 Formic Acid 45 0.55 5.0 mg/L 142-62-1 Hexanoic Acid 0.58U 0.58 5.0 mg/L 646-07-1 i-Hexanoic Acid 0.56U 0.56 5.0 mg/L 503-74-2 i-Pentanoic Acid 0.61 U 0.61 5.0 mg/L 50-21-5 Lactic Acid 0.53U 0.53 5.0 mg/L 109-52-4 Pentanoic Acid 0.56U 0.56 5.0 mg/L 79-09-4 Propionic Acid 0.53U 0.53 5.0 mg/L 127-17-3 Pyruvic Acid 0.60U 0.60 5.0 mg/L AM20GAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/11/202112:07 JCK2 710674 CAS# Parameter Result DL LOQ Units 74-84-0 Ethane 0.075U 0.075 1.0 ug/L 74-85-1 Ethene 0.70J 0.12 1.0 ug/L 74-82-8 Methane 450 2.5 5.0 ug/L Collect Date 04/29/2021 11:45 LAB ID 22105050906 MW-19-75 Receive Date 05/04/2021 10:21 Matrix Water EPA RSK-175 Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 10 05/13/202110:56 BMR 711077 CAS# Parameter Result DL LOQ Units 124-38-9 Carbon Dioxide 94400 1270 9000 ug/L AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 10 05/08/202123:14 MOS 710558 CAS# Parameter 64-19-7 Acetic Acid 107-92-6 Butyric Acid Result DL LOQ Units 2.6J 1.2 5.0 mg/L 0.58U 0.58 5.0 mg/L Pace Gulf Coast Report#: 221050509 Page 11 of 22 Page 164 of 175 aceArulytrca! Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Sample Results Collect Date 04/29/2021 11:45 LAB ID 22105050906 MW-19-75 Receive Date 05/04/2021 10:21 Matrix Water AM23G (Continued) Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 10 05/08/202123:14 MOS 710558 CAS# Parameter Result DL LOQ Units 64-18-6 Formic Acid 53 0.55 5.0 mg/L 142-62-1 Hexanoic Acid 0.58U 0.58 5.0 mg/L 646-07-1 i-Hexanoic Acid 0.56U 0.56 5.0 mg/L 503-74-2 i-Pentanoic Acid 0.61 U 0.61 5.0 mg/L 50-21-5 Lactic Acid 0.53U 0.53 5.0 mg/L 109-52-4 Pentanoic Acid 0.56U 0.56 5.0 mg/L 79-09-4 Propionic Acid 0.53U 0.53 5.0 mg/L 127-17-3 Pyruvic Acid 0.60U 0.60 5.0 mg/L AM20GAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/11/202112:19 JCK2 710674 CAS# Parameter Result DL LOQ Units 74-84-0 Ethane 0.62J 0.075 1.0 ug/L 74-85-1 Ethene 0.12U 0.12 1.0 ug/L 74-82-8 Methane 1400 2.5 5.0 ug/L Collect Date 04/29/2021 13:10 LAB ID 22105050907 MW-19-110 Receive Date 05/04/2021 10:21 Matrix Water EPA RSK-175 Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/13/202111:02 BMR 711077 CAS# Parameter Result DL LOQ Units 124-38-9 Carbon Dioxide 3840 127 900 ug/L AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 2 05/09/202100:08 MOS 710558 CAS# Parameter 64-19-7 Acetic Acid 107-92-6 Butyric Acid 64-18-6 Formic Acid 142-62-1 Hexanoic Acid 646-07-1 i-Hexanoic Acid 503-74-2 i-Pentanoic Acid 50-21-5 Lactic Acid 109-52-4 Pentanoic Acid 79-09-4 Propionic Acid 127-17-3 Pyruvic Acid Result DL LOQ Units 0.52J 0.25 1.0 mg/L 0.12U 0.12 1.0 mg/L 12 0.11 1.0 mg/L 0.12U 0.12 1.0 mg/L 0.11 U 0.11 1.0 mg/L 0.12U 0.12 1.0 mg/L 0.11 U 0.11 1.0 mg/L 0.11 U 0.11 1.0 mg/L 0.11 U 0.11 1.0 mg/L 0.12U 0.12 1.0 mg/L Pace Gulf Coast Report#: 221050509 Page 12 of 22 Page 165 of 175 Report#: 221050509 10;aceAr�alytrca! Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Sample Results Collect Date 04/29/2021 13:10 LAB ID 22105050907 MW-19-110 Receive Date 05/04/2021 10:21 Matrix Water AM20GAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/11/202112:30 JCK2 710674 CAS# Parameter Result DL LOQ Units 74-84-0 Ethane 0.18J 0.075 1.0 ug/L 74-85-1 Ethene 0.12U 0.12 1.0 ug/L 74-82-8 Methane 170 2.5 5.0 ug/L Collect Date 04/29/2021 12:20 LAB ID 22105050908 MW-21-21 Receive Date 05/04/2021 10:21 Matrix Water EPA RSK-175 Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 30 05/13/202111:14 BMR 711077 CAS# Parameter Result DL LOQ Units 124-38-9 Carbon Dioxide 341000 3810 27000 ug/L AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 10 05/09/202101:01 MOS 710558 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 3.8J 1.2 5.0 mg/L 107-92-6 Butyric Acid 0.58U 0.58 5.0 mg/L 64-18-6 Formic Acid 47 0.55 5.0 mg/L 142-62-1 Hexanoic Acid 0.58U 0.58 5.0 mg/L 646-07-1 i-Hexanoic Acid 0.56U 0.56 5.0 mg/L 503-74-2 i-Pentanoic Acid 0.61 U 0.61 5.0 mg/L 50-21-5 Lactic Acid 0.53U 0.53 5.0 mg/L 109-52-4 Pentanoic Acid 0.56U 0.56 5.0 mg/L 79-09-4 Propionic Acid 0.53U 0.53 5.0 mg/L 127-17-3 Pyruvic Acid 0.60U 0.60 5.0 mg/L AM20GAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/11/202112:42 JCK2 710674 CAS# Parameter 74-84-0 Ethane 74-85-1 Ethene 74-82-8 Methane Result DL LOQ Units 0.32J 0.075 1.0 ug/L 0.46J 0.12 1.0 ug/L 2200 2.5 5.0 ug/L Pace Gulf Coast Report#: 221050509 Page 13 of 22 Page 166 of 175 Report#: 221050509 10;aceAr�alytrca! Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Sample Results Collect Date 04/29/2021 10:45 LAB ID 22105050909 MW-21-94 Receive Date 05/04/2021 10:21 Matrix Water EPA RSK-175 Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 5 05/13/202111:18 BMR 711077 CAS# Parameter Result DL LOQ Units 124-38-9 Carbon Dioxide 77100 635 4500 ug/L AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 10 05/09/202101:55 MOS 710558 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 2.4J 1.2 5.0 mg/L 107-92-6 Butyric Acid 0.58U 0.58 5.0 mg/L 64-18-6 Formic Acid 49 0.55 5.0 mg/L 142-62-1 Hexanoic Acid 0.58U 0.58 5.0 mg/L 646-07-1 i-Hexanoic Acid 0.56U 0.56 5.0 mg/L 503-74-2 i-Pentanoic Acid 0.61 U 0.61 5.0 mg/L 50-21-5 Lactic Acid 0.53U 0.53 5.0 mg/L 109-52-4 Pentanoic Acid 0.56U 0.56 5.0 mg/L 79-09-4 Propionic Acid 0.53U 0.53 5.0 mg/L 127-17-3 Pyruvic Acid 0.60U 0.60 5.0 mg/L AM20GAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/11/202112:53 JCK2 710674 CAS# Parameter Result DL LOQ Units 74-84-0 Ethane 0.75J 0.075 1.0 ug/L 74-85-1 Ethene 0.28J 0.12 1.0 ug/L 74-82-8 Methane 2000 2.5 5.0 ug/L Collect Date 04/29/2021 16:45 LAB ID 22105050910 MW-24-160 Receive Date 05/04/2021 10:21 Matrix Water EPA RSK-175 Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/13/202111:23 BMR 711077 CAS# Parameter Result DL LOQ Units 124-38-9 Carbon Dioxide 1360 127 900 ug/L AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/09/202102:48 MOS 710558 CAS# Parameter 64-19-7 Acetic Acid 107-92-6 Butyric Acid Result DL LOQ Units 0.27J 0.12 0.50 mg/L 0.058U 0.058 0.50 mg/L Pace Gulf Coast Report#: 221050509 Page 14 of 22 Page 167 of 175 aceAnalytica! Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Sample Results Collect Date 04/29/2021 16:45 LAB ID 22105050910 MW-24-160 Receive Date 05/04/2021 10:21 Matrix Water 3G (Continued) Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/09/202102:48 MOS 710558 CAS# Parameter Result DL LOQ Units 64-18-6 Formic Acid 5.3 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.058U 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.056U 0.056 0.50 mg/L 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.053U 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.056U 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.053U 0.053 0.50 mg/L 127-17-3 Pyruvic Acid 0.060U 0.060 0.50 mg/L AM20GAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/11/202113:05 JCK2 710674 CAS# Parameter Result DL LOQ Units 74-84-0 Ethane 0.075U 0.075 1.0 ug/L 74-85-1 Ethene 0.36J 0.12 1.0 ug/L 74-82-8 Methane 35 2.5 5.0 ug/L Collect Date 04/29/2021 10:00 LAB ID 22105050911 MW-2 (H2) Receive Date 05/04/2021 10:21 Matrix Bubble Strip OGAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 8 05/10/202116:14 JCK2 710741 CAS# Parameter Result DL LOQ Units 1333-74-0 Hydrogen 120 3.9 15 nM Collect Date 04/29/2021 14:10 LAB ID 22105050912 MW-4 (H2) Receive Date 05/04/2021 10:21 Matrix Bubble Strip OGAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/10/202113:58 JCK2 710741 CAS# Parameter 1333-74-0 Hydrogen Result DL LOQ Units 0.76J 0.49 1.9 nM Pace Gulf Coast Report#: 221050509 Page 15 of 22 Page 168 of 175 aceAnalytica! Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Sample Results Collect Date 04/29/2021 12:05 LAB ID 22105050913 MW-6 (H2) Receive Date 05/04/2021 10:21 Matrix Bubble Strip OGAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/10/202114:16 JCK2 710741 CAS# Parameter Result DL LOQ Units 1333-74-0 Hydrogen 22 0.49 1.9 nM Collect Date 04/29/2021 13:55 LAB ID 22105050914 MW-13-132 (H2) Receive Date 05/04/2021 10:21 Matrix Bubble Strip OGAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/10/202114:34 JCK2 710741 CAS# Parameter Result DL LOQ Units 1333-74-0 Hydrogen 20 0.49 1.9 nM Collect Date 04/29/2021 10:10 LAB ID 22105050915 MW-18-78 (H2) Receive Date 05/04/2021 10:21 Matrix Bubble Strip OGAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/10/202114:46 JCK2 710741 CAS# Parameter 1333-74-0 Hydrogen AM20GAX Result DL LOQ Units 0.49U 0.49 1.9 nM Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/10/202114:46 JCK2 710741 CAS# Parameter Result DL LOQ Units 1333-74-0 Hydrogen 0.49U 0.49 1.9 nM Collect Date 04/29/2021 11:45 LAB ID 22105050916 MW-19-75 (H2) Receive Date 05/04/2021 10:21 Matrix Bubble Strip OGAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/10/202114:58 JCK2 710741 CAS# Parameter 1333-74-0 Hydrogen Result DL LOQ Units 0.95J 0.49 1.9 nM Pace Gulf Coast Report#: 221050509 Page 16 of 22 Page 169 of 175 Report#: 221050509 10;aceAr�alytrca! Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 Sample Results Collect Date 04/29/2021 13:10 LAB ID 22105050917 MW-19-110 (H2) Receive Date 05/04/2021 10:21 Matrix Bubble Strip OGAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/10/202115:11 JCK2 710741 CAS# Parameter Result DL LOQ Units 1333-74-0 Hydrogen 3.4 0.49 1.9 nM Collect Date 04/29/2021 12:20 LAB ID 22105050918 MW-21-21 (H2) Receive Date 05/04/2021 10:21 Matrix Bubble Strip OGAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/10/202115:25 JCK2 710741 CAS# Parameter Result DL LOQ Units 1333-74-0 Hydrogen 8.4 0.49 1.9 nM Collect Date 04/29/2021 10:45 LAB ID 22105050919 MW-21-94 (H2) Receive Date 05/04/2021 10:21 Matrix Bubble Strip OGAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/10/202115:37 JCK2 710741 CAS# Parameter Result DL LOQ Units 1333-74-0 Hydrogen 17 0.49 1.9 nM Collect Date 04/29/2021 16:45 LAB ID 22105050920 MW-24-160 (H2) Receive Date 05/04/2021 10:21 Matrix Bubble Strip OGAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 05/10/202115:50 JCK2 710741 CAS# Parameter 1333-74-0 Hydrogen Result DL LOQ Units 4.2 0.49 1.9 nM Pace Gulf Coast Report#: 221050509 Page 17 of 22 Page 170 of 175 1 21'Amlytical Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 GC Volatiles QC Summary Analytical Batch Client ID MB711077 LCS711077 LCSD711077 711077 LAB ID 2185672 2185673 2185674 Sample Type MB LCS LCSD Prep Date Analysis Date 05/13/21 09:31 05/13/21 09:37 05/13/21 09:43 Matrix Water Water Water EPA RSK-175 Units ug/L Spike I Result %R Control Spike Result I %R I RPD I RPD I Result DLI Added Limits%R 1 Added Limit Carbon Dioxide 124-38-9 127U 127 8700 8580 99 38 - 147 8700 8750 101 2 40 Pace Gulf Coast Report#: 221050509 Page 18 of 22 Page 171 of 175 1 21'Amlytical Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 General Chemistry QC Summary Analytical Batch Client ID MB710558 LCS710558 LCSD710558 710558 LAB ID 2182968 2182969 2182970 Sample Type MB LCS LCSD Prep Date Analysis Date 05/08/21 10:47 05/08/21 09:53 05/08/21 20:34 Matrix Water Water Water AM23G Units mg/L Spike Result %R Control Spike Result %R RPD RPD Result DL Added Limits%R Added Limit Acetic Acid 64-19-7 0.12U 0.12 2.0 1.9 96 70 - 130 2.0 1.9 96 0 20 Butyric Acid 107-92-6 0.058U 0.058 2.0 1.9 96 70 - 130 2.0 1.9 96 0 20 Formic Acid 64-18-6 0.055U 0.055 2.0 1.8 89 70 - 130 2.0 1.8 90 1 20 Hexanoic Acid 142-62-1 0.058U 0.058 2.0 1.8 93 70 - 130 2.0 1.8 92 0 20 i-Hexanoic Acid 646-07-1 0.056U 0.056 2.0 2.0 98 70 - 130 2.0 1.8 88 11 20 i-Pentanoic Acid 503-74-2 0.061 U 0.061 2.0 1.9 94 70 - 130 2.0 1.9 95 1 20 Lactic Acid 50-21-5 0.053U 0.053 2.0 1.8 88 70 - 130 2.0 1.8 89 1 20 Pentanoic Acid 109-52-4 0.056U 0.056 2.0 1.8 92 70 - 130 2.0 1.8 93 0 20 Propionic Acid 79-09-4 0.053U 0.053 2.0 1.8 91 70 - 130 2.0 1.8 91 0 20 Pyruvic Acid 127-17-3 0.060U 0.060 2.0 1.8 88 70 - 130 2.0 1.8 90 2 20 Pace Gulf Coast Report#: 221050509 Page 19 of 22 Page 172 of 175 1 21'Amlytical Report#: 221050509 Project ID: WD30017 Closed Buncombe Wells Report Date: 05/18/2021 General Chromatography QC Summary Analytical Batch Client ID MB710741 LCS710741 LCSD710741 710741 LAB ID 2183943 2183944 2183945 Sample Type MB LCS LCSD Prep Date Analysis Date 05/10/21 10:52 05/10/21 11:08 05/10/21 11:21 Matrix AM20GAX Units nM Spike Result %R Control Spike Result %R RPD RPD Result DL Added Limits%R Added Limit Hydrogen 1333-74-0 0.49U 1 0.491 121 9.5180 1 70 - 130 1 121 10185 1 20 Analytical Batch Client ID MB710674 LCS710674 LCSD710674 710674 LAB ID 2183699 2183700 2183701 Sample Type MB LCS LCSD Prep Date Analysis Date 05/11/21 10:46 05/11/21 10:12 05/11/21 10:24 Matrix Water Water Water AM20GAX Units ug/L Spike I Result %R Control Spike Result %R RPD RPD Result DL Added Limits'/, R Added Limit Ethane 74-84-0 0.075U 0.075 97 99 102 70-130 97 100 103 1 20 Ethene 74-85-1 0.12U 0.12 120 120 104 70 - 130 120 130 107 2 20 Methane 74-82-8 2.5U 2.5 380 380 100 70 - 130 380 390 101 2 20 Pace Gulf Coast Report#: 221050509 Page 20 of 22 Page 173 of 175 Chain of Custody workorder: WD30017 Workorder Name: Closed Buncombe Wells Owner Received Date: 30-Apr !- aceAnalytfcal Results Requested By: 14-May Report To: Subcontract To: Requested Analysis Pace Analytical West Columbia Pace Gulf Coast 106 Vantage Point Dr. Ruth Welsh West Columbia, SC 29172 803-206-9537 Lucas Odom PreserveTIXIXIXI Q j v m o v = V; o ry U -o m u, g LAB USE ONLYI Item Sample ID Sample Type Collect Date/Time Lab ID Matrix 1 MW-2 Grab 04/29/21 @ 1000 WD30017-009 aqueous 2 MW-4 Grab 04/29/21 @ 1410 WD30017-011 aqueous X X X 3 MW-6 Grab 04/29/21 @ 1205 WD30017-010 aqueous X X X 3 4 MW-13-132 Grab 04/29/21 @ 1355 WD30017-015 aqueous X X X I- 5 MW-18-78 Grab 04/29/21 @ 1010 WD30017-019 aqueous X X X 6 MW-19-75 Grab 04/29/21 @ 1145 WD30017-020 aqueous X X X Lo- 7 MW-19-110 Grab 04/29/21 @ 1310 WD30017-021 aqueous X X X 8 MW-21-21 Grab 04/29/21 @ 1220 WD30017-022 aqueous X X X MW-21-94 Grab 04/29/21 @ 1045 WD30017-023 aqueous --i X X X �] iL 10 MW-24-160 Grab 04/29/21 @ 1645 WD30017-024 aqueous i9 X X X (] Transfers RelptksedBy Date/Time Reveived By Date/Time Comments 1 3 (� report "J" values 121UE3ewpm � 2 MA VAM•2 3 Cooler Temperature on Receipt °CI Custody Seal Y or N Received on Ice Y or N I Sample Intact Y or N ***In order to maintain client confidentiality, location/name of the sampling site, sampler's name and signature may not be provided on this COC This chain of custody is considered complete as is since this information is available in the owner laboratory. Friday, June 17, 201611:01:34 AM Ii I (At-,51 -�, L U5 1�305 FMT-ALL-C-002rev.0( Client ID: Shealy Envir - Pace Analytical Services South Carolina SDG: 221050509 PM: RWe Pace Gulf Coast Report#: 221050509 Page 21 of 22 Page 174 of 175 i'auaimiytn:s SAMPLE RECEIVING CHECKLIST IIIIIIAIIIII SAMPLE DELIVERY GROUP 221050509 CHECKLIST YES NO Client PM RUUe Transport Method Samples received with proper thermal preservation? *❑ ❑ Shealy Envir - Pace Analytical FEDDC Services South Carolina Radioactivity is <1600 cpm? If no, record cpm value in notes section. COC relinquished and complete (including samplelDs, collect times, and sampler)? *❑ *❑ ❑ ❑ Profile Number Received By 285031 N/bane, Dodie K All containers received in good condition and within hold time? All sample labels and containers received match the chain of custody? *❑ 0 ❑ ❑ Line Item(s) Receive Date(s) 1 - LHC and Perm gases VFA 05/04/21 2- Hydrogen Preservative added to any containers? ❑ 0 If received, was headspace for VOC water containers < 6mm? 0 ❑ Samples collected in containers provided by Pace Gulf Coast? 0 ❑ COOLERS DISCREPANCIES LAB PRESERVATIONS Airbill Thermometer ID E38 Temp °C None None 166334654385 2.6 NOTES Pevision 1.6 Pace Gulf Coast Report#: 221050509 Page 175 of 175 Page 1 of 1 Page 22 of 22 0 aceAnalytical Report of Analysis Bunnell-Lammons Engineering, Inc. 6004 Ponders Court Greenville, SC 29615 Attention: Andy Alexander Project Name: Closed Buncombe County Landfill Surface Water Project Number: J21-14175-05 Lot Number:WD30011 Date Completed:05/12/2021 05/19/2021 8:29 AM Approved and released by: Project Manager II: Lucas Odom PCCRF� 24rA SOA / ANSI National Accreditation Board A C C R E D I T E D TESTING LABORATORY The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 1 of 39 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative Bunnell-Lammons Engineering, Inc. Lot Number: WD30011 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved The NELAC Institute (TNI) standards, the Pace Analytical Services, LLC ("Pace") Laboratory Quality Manual, standard operating procedures (SOPS), and Pace policies. Any exceptions to the TNI standards, the Laboratory Quality Manual, SOPS or policies are qualified on the results page or discussed below. If you have any questions regarding this report please contact the Pace Project Manager listed on the cover page. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 whw.pacelabs.com Page 2 of 39 PACE ANALYTICAL SERVICES, LLC Sample Summary Bunnell-Lammons Engineering, Inc. Lot Number: WD30011 Sample Number Sample ID Matrix Date Sampled Date Received 001 SW-1 Aqueous 04/28/20210945 04/29/2021 002 SW-2 Aqueous 04/28/20211020 04/29/2021 003 SW-2A Aqueous 04/28/20211030 04/29/2021 004 SW-3 Aqueous 04/28/20211145 04/29/2021 005 SW-4 Aqueous 04/28/20211105 04/29/2021 006 Trip Blank Aqueous 04/28/2021 04/29/2021 (6 samples) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 3 of 39 PACE ANALYTICAL SERVICES, LLC Detection Summary Bunnell-Lammons Engineering, Inc. Lot Number: WD30011 Sample Sample ID Matrix Parameter Method Result Q Units Page 001 SW-1 Aqueous Barium 6020B 14 ug/L 6 001 SW-1 Aqueous Lead 6020B 0.50 J ug/L 6 001 SW-1 Aqueous Zinc 6020B 11 ug/L 6 002 SW-2 Aqueous Barium 6020B 14 ug/L 8 002 SW-2 Aqueous Zinc 6020B 3.9 J ug/L 8 003 SW-2A Aqueous 1,4-Dioxane 8260D (SIM) 12 ug/L 9 003 SW-2A Aqueous Barium 6020B 35 ug/L 10 003 SW-2A Aqueous Copper 6020B 5.7 ug/L 10 003 SW-2A Aqueous Nickel 6020B 1.6 J ug/L 10 004 SW-3 Aqueous 1,4-Dioxane 8260D (SIM) 34 ug/L 12 004 SW-3 Aqueous Barium 6020B 110 ug/L 13 004 SW-3 Aqueous Cobalt 6020B 3.2 J ug/L 13 004 SW-3 Aqueous Nickel 6020B 4.0 J ug/L 13 005 SW-4 Aqueous 1,4-Dioxane 8260D (SIM) 68 ug/L 15 005 SW-4 Aqueous Barium 6020B 120 ug/L 16 005 SW-4 Aqueous Cobalt 6020B 10 ug/L 16 005 SW-4 Aqueous Nickel 6020B 20 ug/L 16 005 SW-4 Aqueous Selenium 6020B 1.7 J ug/L 17 (18 detections) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 4 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-001 Description: SW-1 Matrix: Aqueous Date Sampled:04/28/2021 0945 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211525 TML 91866 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 5 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-001 Description: SW-1 Matrix: Aqueous Date Sampled:04/28/2021 0945 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211525 TML 91866 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 101 70-130 1,2-Dichloroethane-d4 111 70-130 Toluene-d8 110 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1751 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 14 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.50 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 11 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 6 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-002 Description: SW-2 Matrix: Aqueous Date Sampled:04/28/2021 1020 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211549 TML 91866 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 7 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-002 Description: SW-2 Matrix: Aqueous Date Sampled:04/28/2021 1020 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211549 TML 91866 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 101 70-130 1,2-Dichloroethane-d4 111 70-130 Toluene-d8 112 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1757 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 14 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B ND 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 3.9 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 8 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-003 Description: SW-2A Matrix: Aqueous Date Sampled:04/28/2021 1030 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0106 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 12 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 96 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211613 TML 91866 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 9 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-003 Description: SW-2A Matrix: Aqueous Date Sampled:04/28/2021 1030 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211613 TML 91866 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 99 70-130 1,2-Dichloroethane-d4 111 70-130 Toluene-d8 109 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1803 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 35 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B ND 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.7 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.6 J 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 10 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-003 Description: SW-2A Matrix: Aqueous Date Sampled:04/28/2021 1030 Date Received:04/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1803 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 11 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-004 Description: SW-3 Matrix: Aqueous Date Sampled:04/28/2021 1145 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0131 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 34 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 98 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20210229 CJL2 91963 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 12 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-004 Description: SW-3 Matrix: Aqueous Date Sampled:04/28/2021 1145 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/12/20210229 CJL2 91963 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 102 70-130 1,2-Dichloroethane-d4 90 70-130 Toluene-d8 94 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1809 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 110 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 3.2 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 4.0 J 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 13 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-004 Description: SW-3 Matrix: Aqueous Date Sampled:04/28/2021 1145 Date Received:04/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1809 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 6020B ND 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 14 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-005 Description: SW-4 Matrix: Aqueous Date Sampled:04/28/2021 1105 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS (SIM) Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 05/04/2021 0156 CJL2 91037 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 68 3.0 1.0 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 98 40-170 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211133 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L 1 Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L 1 Benzene 71-43-2 8260D ND 1.0 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L 1 Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L 1 Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L 1 Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 15 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-005 Description: SW-4 Matrix: Aqueous Date Sampled:04/28/2021 1105 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211133 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 1 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L 1 Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L 1 Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 107 70-130 1,2-Dichloroethane-d4 96 70-130 Toluene-d8 100 70-130 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1815 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B ND 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B ND 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 120 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B ND 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B ND 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B ND 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 10 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B ND 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B ND 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 20 5.0 1.3 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 16 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-005 Description: SW-4 Matrix: Aqueous Date Sampled:04/28/2021 1105 Date Received:04/29/2021 ICP-MS Metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 05/03/2021 1815 BNW 05/03/2021 0426 90835 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Selenium 7782-49-2 6020B 1.7 J 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B ND 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B ND 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B ND 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B ND 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 17 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-006 Description: Trip Blank Matrix: Aqueous Date Sampled:04/28/2021 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211043 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D ND 20 5.0 ug/L Acrylonitrile 107-13-1 8260D ND 20 0.80 ug/L Benzene 71-43-2 8260D ND 1.0 0.40 ug/L Bromochloromethane 74-97-5 8260D ND 1.0 0.40 ug/L Bromodichloromethane 75-27-4 8260D ND 1.0 0.40 ug/L Bromoform 75-25-2 8260D ND 1.0 0.40 ug/L Bromomethane (Methyl bromide) 74-83-9 8260D ND 2.0 0.40 ug/L 2-Butanone (MEK) 78-93-3 8260D ND 10 2.0 ug/L Carbon disulfide 75-15-0 8260D ND 1.0 0.40 ug/L Carbon tetrachloride 56-23-5 8260D ND 1.0 0.40 ug/L Chlorobenzene 108-90-7 8260D ND 1.0 0.40 ug/L Chloroethane 75-00-3 8260D ND 2.0 0.40 ug/L Chloroform 67-66-3 8260D ND 1.0 0.40 ug/L Chloromethane (Methyl chloride) 74-87-3 8260D ND 1.0 0.50 ug/L 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D ND 1.0 0.40 ug/L Dibromochloromethane 124-48-1 8260D ND 1.0 0.40 ug/L 1,2-Dibromoethane (EDB) 106-93-4 8260D ND 1.0 0.40 ug/L Dibromomethane (Methylene bromide) 74-95-3 8260D ND 1.0 0.40 ug/L trans- 1,4-Dichloro-2-butene 110-57-6 8260D ND 2.0 0.50 ug/L 1,2-Dichlorobenzene 95-50-1 8260D ND 1.0 0.40 ug/L 1,4-Dichlorobenzene 106-46-7 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethane 75-34-3 8260D ND 1.0 0.40 ug/L 1,2-Dichloroethane 107-06-2 8260D ND 1.0 0.40 ug/L 1,1-Dichloroethene 75-35-4 8260D ND 1.0 0.40 ug/L cis- 1,2-Dichloroethene 156-59-2 8260D ND 1.0 0.40 ug/L trans- 1,2-Dichloroethene 156-60-5 8260D ND 1.0 0.40 ug/L 1,2-Dichloropropane 78-87-5 8260D ND 1.0 0.40 ug/L cis- 1,3-Dichloropropene 10061-01-5 8260D ND 1.0 0.40 ug/L trans- 1,3-Dichloropropene 10061-02-6 8260D ND 1.0 0.40 ug/L Ethylbenzene 100-41-4 8260D ND 1.0 0.40 ug/L 2-Hexanone 591-78-6 8260D ND 10 2.0 ug/L Methyl iodide (lodomethane) 74-88-4 8260D ND 5.0 0.40 ug/L 4-Methyl-2-pentanone 108-10-1 8260D ND 10 2.0 ug/L Methylene chloride 75-09-2 8260D ND 1.0 0.40 ug/L Styrene 100-42-5 8260D ND 1.0 0.41 ug/L 1,1,1,2-Tetrachloroethane 630-20-6 8260D ND 1.0 0.40 ug/L 1,1,2,2-Tetrachloroethane 79-34-5 8260D ND 1.0 0.40 ug/L Tetrachloroethene 127-18-4 8260D ND 1.0 0.40 ug/L Toluene 108-88-3 8260D ND 1.0 0.40 ug/L 1,1,1-Trichloroethane 71-55-6 8260D ND 1.0 0.40 ug/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 18 of 39 Client: Bunnell-Lammons Engineering, Inc. Laboratory ID:WD30011-006 Description: Trip Blank Matrix: Aqueous Date Sampled:04/28/2021 Date Received:04/29/2021 Volatile Organic Compounds by GC/MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 05/11/20211043 BWS 91880 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,1,2-Trichloroethane 79-00-5 8260D ND 1.0 0.40 ug/L 1 Trichloroethene 79-01-6 8260D ND 1.0 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D ND 1.0 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D ND 1.0 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D ND 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D ND 1.0 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D ND 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 114 70-130 96 70-130 101 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure NO = Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 19 of 39 QC Summary Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 20 of 39 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: WQ91037-001 Matrix: Aqueous Batch: 91037 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane ND 1 3.0 1.0 ug/L 05/03/2021 2257 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 93 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 21 of 39 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: WQ91037-002 Matrix: Aqueous Batch: 91037 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 46 1 93 70-130 05/03/2021 2155 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 96 40-170 ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 22 of 39 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ91866-001 Matrix: Aqueous Batch: 91866 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 05/11/2021 1007 Acrylonitrile ND 1 20 0.80 ug/L 05/11/2021 1007 Benzene ND 1 1.0 0.40 ug/L 05/11/2021 1007 Bromochloromethane ND 1 1.0 0.40 ug/L 05/11/2021 1007 Bromodichloromethane ND 1 1.0 0.40 ug/L 05/11/2021 1007 Bromoform ND 1 1.0 0.40 ug/L 05/11/2021 1007 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 05/11/2021 1007 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/11/2021 1007 Carbon disulfide ND 1 1.0 0.40 ug/L 05/11/2021 1007 Carbon tetrachloride ND 1 1.0 0.40 ug/L 05/11/2021 1007 Chlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 1007 Chloroethane ND 1 2.0 0.40 ug/L 05/11/2021 1007 Chloroform ND 1 1.0 0.40 ug/L 05/11/2021 1007 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 05/11/2021 1007 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 05/11/2021 1007 Dibromochloromethane ND 1 1.0 0.40 ug/L 05/11/2021 1007 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 05/11/2021 1007 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 05/11/2021 1007 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 05/11/2021 1007 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 1007 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 1007 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 1007 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 1007 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 1007 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 1007 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 1007 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 05/11/2021 1007 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/11/2021 1007 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/11/2021 1007 Ethylbenzene ND 1 1.0 0.40 ug/L 05/11/2021 1007 2-Hexanone ND 1 10 2.0 ug/L 05/11/2021 1007 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/11/2021 1007 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/11/2021 1007 Methylene chloride ND 1 1.0 0.40 ug/L 05/11/2021 1007 Styrene ND 1 1.0 0.41 ug/L 05/11/2021 1007 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/11/2021 1007 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/11/2021 1007 Tetrachloroethene ND 1 1.0 0.40 ug/L 05/11/2021 1007 Toluene ND 1 1.0 0.40 ug/L 05/11/2021 1007 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 1007 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 1007 Trichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 1007 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 05/11/2021 1007 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 05/11/2021 1007 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 23 of 39 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ91866-001 Matrix: Aqueous Batch: 91866 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 05/11/2021 1007 Vinyl chloride ND 1 1.0 0.40 ug/L 05/11/2021 1007 Xylenes (total) ND 1 1.0 0.40 ug/L 05/11/2021 1007 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 101 70-130 1,2-Dichloroethane-d4 111 70-130 Toluene-d8 111 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 24 of 39 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ91866-002 Matrix: Aqueous Batch: 91866 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 110 1 106 60-140 05/11/2021 0842 Acrylonitrile 100 110 1 107 70-130 05/11/2021 0842 Benzene 50 51 1 103 70-130 05/11/2021 0842 Bromochloromethane 50 51 1 103 70-130 05/11/2021 0842 Bromodichloromethane 50 52 1 104 70-130 05/11/2021 0842 Bromoform 50 53 1 106 70-130 05/11/2021 0842 Bromomethane (Methyl bromide) 50 51 1 101 70-130 05/11/2021 0842 2-Butanone (MEK) 100 110 1 113 70-130 05/11/2021 0842 Carbon disulfide 50 52 1 104 70-130 05/11/2021 0842 Carbon tetrachloride 50 50 1 101 70-130 05/11/2021 0842 Chlorobenzene 50 51 1 101 70-130 05/11/2021 0842 Chloroethane 50 52 1 104 70-130 05/11/2021 0842 Chloroform 50 51 1 102 70-130 05/11/2021 0842 Chloromethane (Methyl chloride) 50 54 1 107 60-140 05/11/2021 0842 1,2-Dibromo-3-chloropropane (DBCP) 50 53 1 106 70-130 05/11/2021 0842 Dibromochloromethane 50 52 1 104 70-130 05/11/2021 0842 1,2-Dibromoethane (EDB) 50 51 1 102 70-130 05/11/2021 0842 Dibromomethane (Methylene bromide) 50 51 1 102 70-130 05/11/2021 0842 trans- 1,4-Dichloro-2-butene 50 57 1 113 70-130 05/11/2021 0842 1,2-Dichlorobenzene 50 51 1 102 70-130 05/11/2021 0842 1,4-Dichlorobenzene 50 49 1 99 70-130 05/11/2021 0842 1,1-Dichloroethane 50 52 1 105 70-130 05/11/2021 0842 1,2-Dichloroethane 50 51 1 102 70-130 05/11/2021 0842 1,1-Dichloroethene 50 52 1 103 70-130 05/11/2021 0842 cis- 1,2-Dichloroethene 50 52 1 104 70-130 05/11/2021 0842 trans- 1,2-Dichloroethene 50 52 1 105 70-130 05/11/2021 0842 1,2-Dichloropropane 50 53 1 105 70-130 05/11/2021 0842 cis- 1,3-Dichloropropene 50 55 1 111 70-130 05/11/2021 0842 trans- 1,3-Dichloropropene 50 56 1 112 70-130 05/11/2021 0842 Ethylbenzene 50 53 1 107 70-130 05/11/2021 0842 2-Hexanone 100 120 1 119 70-130 05/11/2021 0842 Methyl iodide (lodomethane) 50 47 1 95 70-130 05/11/2021 0842 4-Methyl-2-pentanone 100 120 1 117 70-130 05/11/2021 0842 Methylene chloride 50 50 1 100 70-130 05/11/2021 0842 Styrene 50 56 1 112 70-130 05/11/2021 0842 1,1,1,2-Tetrachloroethane 50 50 1 101 70-130 05/11/2021 0842 1,1,2,2-Tetrachloroethane 50 51 1 102 70-130 05/11/2021 0842 Tetrachloroethene 50 50 1 100 70-130 05/11/2021 0842 Toluene 50 53 1 106 70-130 05/11/2021 0842 1,1,1-Trichloroethane 50 50 1 100 70-130 05/11/2021 0842 1,1,2-Trichloroethane 50 50 1 101 70-130 05/11/2021 0842 Trichloroethene 50 49 1 99 70-130 05/11/2021 0842 Trichlorofluoromethane 50 46 1 93 70-130 05/11/2021 0842 1,2,3-Trichloropropane 50 50 1 101 70-130 05/11/2021 0842 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 25 of 39 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ91866-002 Matrix: Aqueous Batch: 91866 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 51 1 101 60-140 05/11/2021 0842 Vinyl chloride 50 54 1 108 70-130 05/11/2021 0842 Xylenes (total) 100 110 1 109 70-130 05/11/2021 0842 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 100 70-130 1,2-Dichloroethane-d4 99 70-130 Toluene-d8 100 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 26 of 39 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ91880-001 Matrix: Aqueous Batch: 91880 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 05/11/2021 0945 Acrylonitrile ND 1 20 0.80 ug/L 05/11/2021 0945 Benzene ND 1 1.0 0.40 ug/L 05/11/2021 0945 Bromochloromethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 Bromodichloromethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 Bromoform ND 1 1.0 0.40 ug/L 05/11/2021 0945 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 05/11/2021 0945 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/11/2021 0945 Carbon disulfide ND 1 1.0 0.40 ug/L 05/11/2021 0945 Carbon tetrachloride ND 1 1.0 0.40 ug/L 05/11/2021 0945 Chlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 0945 Chloroethane ND 1 2.0 0.40 ug/L 05/11/2021 0945 Chloroform ND 1 1.0 0.40 ug/L 05/11/2021 0945 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 05/11/2021 0945 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 05/11/2021 0945 Dibromochloromethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 05/11/2021 0945 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 05/11/2021 0945 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 05/11/2021 0945 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 0945 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 0945 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 05/11/2021 0945 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/11/2021 0945 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/11/2021 0945 Ethylbenzene ND 1 1.0 0.40 ug/L 05/11/2021 0945 2-Hexanone ND 1 10 2.0 ug/L 05/11/2021 0945 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/11/2021 0945 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/11/2021 0945 Methylene chloride ND 1 1.0 0.40 ug/L 05/11/2021 0945 Styrene ND 1 1.0 0.41 ug/L 05/11/2021 0945 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 Tetrachloroethene ND 1 1.0 0.40 ug/L 05/11/2021 0945 Toluene ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 Trichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 0945 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 05/11/2021 0945 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 05/11/2021 0945 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 27 of 39 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ91880-001 Matrix: Aqueous Batch: 91880 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 05/11/2021 0945 Vinyl chloride ND 1 1.0 0.40 ug/L 05/11/2021 0945 Xylenes (total) ND 1 1.0 0.40 ug/L 05/11/2021 0945 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 110 70-130 1,2-Dichloroethane-d4 97 70-130 Toluene-d8 100 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 28 of 39 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ91880-002 Matrix: Aqueous Batch: 91880 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 110 1 107 60-140 05/11/2021 0841 Acrylonitrile 100 100 1 105 70-130 05/11/2021 0841 Benzene 50 45 1 89 70-130 05/11/2021 0841 Bromochloromethane 50 47 1 93 70-130 05/11/2021 0841 Bromodichloromethane 50 48 1 95 70-130 05/11/2021 0841 Bromoform 50 45 1 90 70-130 05/11/2021 0841 Bromomethane (Methyl bromide) 50 45 1 89 70-130 05/11/2021 0841 2-Butanone (MEK) 100 100 1 102 70-130 05/11/2021 0841 Carbon disulfide 50 45 1 91 70-130 05/11/2021 0841 Carbon tetrachloride 50 43 1 87 70-130 05/11/2021 0841 Chlorobenzene 50 45 1 90 70-130 05/11/2021 0841 Chloroethane 50 43 1 86 70-130 05/11/2021 0841 Chloroform 50 44 1 87 70-130 05/11/2021 0841 Chloromethane (Methyl chloride) 50 43 1 86 60-140 05/11/2021 0841 1,2-Dibromo-3-chloropropane (DBCP) 50 52 1 105 70-130 05/11/2021 0841 Dibromochloromethane 50 50 1 100 70-130 05/11/2021 0841 1,2-Dibromoethane (EDB) 50 49 1 98 70-130 05/11/2021 0841 Dibromomethane (Methylene bromide) 50 47 1 93 70-130 05/11/2021 0841 trans- 1,4-Dichloro-2-butene 50 44 1 89 70-130 05/11/2021 0841 1,2-Dichlorobenzene 50 47 1 93 70-130 05/11/2021 0841 1,4-Dichlorobenzene 50 44 1 88 70-130 05/11/2021 0841 1,1-Dichloroethane 50 46 1 91 70-130 05/11/2021 0841 1,2-Dichloroethane 50 47 1 93 70-130 05/11/2021 0841 1,1-Dichloroethene 50 44 1 88 70-130 05/11/2021 0841 cis- 1,2-Dichloroethene 50 46 1 92 70-130 05/11/2021 0841 trans- 1,2-Dichloroethene 50 44 1 89 70-130 05/11/2021 0841 1,2-Dichloropropane 50 46 1 93 70-130 05/11/2021 0841 cis- 1,3-Dichloropropene 50 45 1 90 70-130 05/11/2021 0841 trans- 1,3-Dichloropropene 50 45 1 90 70-130 05/11/2021 0841 Ethylbenzene 50 46 1 93 70-130 05/11/2021 0841 2-Hexanone 100 100 1 101 70-130 05/11/2021 0841 Methyl iodide (lodomethane) 50 46 1 93 70-130 05/11/2021 0841 4-Methyl-2-pentanone 100 98 1 98 70-130 05/11/2021 0841 Methylene chloride 50 45 1 90 70-130 05/11/2021 0841 Styrene 50 52 1 104 70-130 05/11/2021 0841 1,1,1,2-Tetrachloroethane 50 49 1 98 70-130 05/11/2021 0841 1,1,2,2-Tetrachloroethane 50 50 1 99 70-130 05/11/2021 0841 Tetrachloroethene 50 44 1 88 70-130 05/11/2021 0841 Toluene 50 47 1 95 70-130 05/11/2021 0841 1,1,1-Trichloroethane 50 45 1 91 70-130 05/11/2021 0841 1,1,2-Trichloroethane 50 48 1 96 70-130 05/11/2021 0841 Trichloroethene 50 42 1 84 70-130 05/11/2021 0841 Trichlorofluoromethane 50 40 1 80 70-130 05/11/2021 0841 1,2,3-Trichloropropane 50 49 1 99 70-130 05/11/2021 0841 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 29 of 39 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ91880-002 Matrix: Aqueous Batch: 91880 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 47 1 93 60-140 05/11/2021 0841 Vinyl chloride 50 43 1 86 70-130 05/11/2021 0841 Xylenes (total) 100 98 1 98 70-130 05/11/2021 0841 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 95 70-130 1,2-Dichloroethane-d4 89 70-130 Toluene-d8 90 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 30 of 39 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ91963-001 Matrix: Aqueous Batch: 91963 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone ND 1 20 5.0 ug/L 05/11/2021 2149 Acrylonitrile ND 1 20 0.80 ug/L 05/11/2021 2149 Benzene ND 1 1.0 0.40 ug/L 05/11/2021 2149 Bromochloromethane ND 1 1.0 0.40 ug/L 05/11/2021 2149 Bromodichloromethane ND 1 1.0 0.40 ug/L 05/11/2021 2149 Bromoform ND 1 1.0 0.40 ug/L 05/11/2021 2149 Bromomethane (Methyl bromide) ND 1 2.0 0.40 ug/L 05/11/2021 2149 2-Butanone (MEK) ND 1 10 2.0 ug/L 05/11/2021 2149 Carbon disulfide ND 1 1.0 0.40 ug/L 05/11/2021 2149 Carbon tetrachloride ND 1 1.0 0.40 ug/L 05/11/2021 2149 Chlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 2149 Chloroethane ND 1 2.0 0.40 ug/L 05/11/2021 2149 Chloroform ND 1 1.0 0.40 ug/L 05/11/2021 2149 Chloromethane (Methyl chloride) ND 1 1.0 0.50 ug/L 05/11/2021 2149 1,2-Dibromo-3-chloropropane (DBCP) ND 1 1.0 0.40 ug/L 05/11/2021 2149 Dibromochloromethane ND 1 1.0 0.40 ug/L 05/11/2021 2149 1,2-Dibromoethane (EDB) ND 1 1.0 0.40 ug/L 05/11/2021 2149 Dibromomethane (Methylene bromide) ND 1 1.0 0.40 ug/L 05/11/2021 2149 trans- 1,4-Dichloro-2-butene ND 1 2.0 0.50 ug/L 05/11/2021 2149 1,2-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 2149 1,4-Dichlorobenzene ND 1 1.0 0.40 ug/L 05/11/2021 2149 1,1-Dichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 2149 1,2-Dichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 2149 1,1-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 2149 cis- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 2149 trans- 1,2-Dichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 2149 1,2-Dichloropropane ND 1 1.0 0.40 ug/L 05/11/2021 2149 cis- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/11/2021 2149 trans- 1,3-Dichloropropene ND 1 1.0 0.40 ug/L 05/11/2021 2149 Ethylbenzene ND 1 1.0 0.40 ug/L 05/11/2021 2149 2-Hexanone ND 1 10 2.0 ug/L 05/11/2021 2149 Methyl iodide (lodomethane) ND 1 5.0 0.40 ug/L 05/11/2021 2149 4-Methyl-2-pentanone ND 1 10 2.0 ug/L 05/11/2021 2149 Methylene chloride ND 1 1.0 0.40 ug/L 05/11/2021 2149 Styrene ND 1 1.0 0.41 ug/L 05/11/2021 2149 1,1,1,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/11/2021 2149 1,1,2,2-Tetrachloroethane ND 1 1.0 0.40 ug/L 05/11/2021 2149 Tetrachloroethene ND 1 1.0 0.40 ug/L 05/11/2021 2149 Toluene ND 1 1.0 0.40 ug/L 05/11/2021 2149 1,1,1-Trichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 2149 1,1,2-Trichloroethane ND 1 1.0 0.40 ug/L 05/11/2021 2149 Trichloroethene ND 1 1.0 0.40 ug/L 05/11/2021 2149 Trichlorofluoromethane ND 1 1.0 0.40 ug/L 05/11/2021 2149 1,2,3-Trichloropropane ND 1 1.0 0.40 ug/L 05/11/2021 2149 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 31 of 39 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ91963-001 Matrix: Aqueous Batch: 91963 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate ND 1 5.0 1.2 ug/L 05/11/2021 2149 Vinyl chloride ND 1 1.0 0.40 ug/L 05/11/2021 2149 Xylenes (total) ND 1 1.0 0.40 ug/L 05/11/2021 2149 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 108 70-130 1,2-Dichloroethane-d4 95 70-130 Toluene-d8 99 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 32 of 39 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ91963-002 Matrix: Aqueous Batch: 91963 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 92 1 92 60-140 05/11/2021 2036 Acrylonitrile 100 110 1 108 70-130 05/11/2021 2036 Benzene 50 49 1 98 70-130 05/11/2021 2036 Bromochloromethane 50 49 1 99 70-130 05/11/2021 2036 Bromodichloromethane 50 49 1 98 70-130 05/11/2021 2036 Bromoform 50 44 1 88 70-130 05/11/2021 2036 Bromomethane (Methyl bromide) 50 51 1 102 70-130 05/11/2021 2036 2-Butanone (MEK) 100 96 1 96 70-130 05/11/2021 2036 Carbon disulfide 50 52 1 104 70-130 05/11/2021 2036 Carbon tetrachloride 50 48 1 97 70-130 05/11/2021 2036 Chlorobenzene 50 47 1 94 70-130 05/11/2021 2036 Chloroethane 50 53 1 107 70-130 05/11/2021 2036 Chloroform 50 47 1 95 70-130 05/11/2021 2036 Chloromethane (Methyl chloride) 50 49 1 98 60-140 05/11/2021 2036 1,2-Dibromo-3-chloropropane (DBCP) 50 53 1 105 70-130 05/11/2021 2036 Dibromochloromethane 50 49 1 99 70-130 05/11/2021 2036 1,2-Dibromoethane (EDB) 50 50 1 99 70-130 05/11/2021 2036 Dibromomethane (Methylene bromide) 50 48 1 97 70-130 05/11/2021 2036 trans- 1,4-Dichloro-2-butene 50 46 1 91 70-130 05/11/2021 2036 1,2-Dichlorobenzene 50 48 1 96 70-130 05/11/2021 2036 1,4-Dichlorobenzene 50 45 1 90 70-130 05/11/2021 2036 1,1-Dichloroethane 50 50 1 100 70-130 05/11/2021 2036 1,2-Dichloroethane 50 49 1 97 70-130 05/11/2021 2036 1,1-Dichloroethene 50 51 1 101 70-130 05/11/2021 2036 cis- 1,2-Dichloroethene 50 50 1 100 70-130 05/11/2021 2036 trans- 1,2-Dichloroethene 50 49 1 98 70-130 05/11/2021 2036 1,2-Dichloropropane 50 49 1 99 70-130 05/11/2021 2036 cis- 1,3-Dichloropropene 50 47 1 94 70-130 05/11/2021 2036 trans- 1,3-Dichloropropene 50 45 1 91 70-130 05/11/2021 2036 Ethylbenzene 50 49 1 98 70-130 05/11/2021 2036 2-Hexanone 100 98 1 98 70-130 05/11/2021 2036 Methyl iodide (lodomethane) 50 52 1 104 70-130 05/11/2021 2036 4-Methyl-2-pentanone 100 99 1 99 70-130 05/11/2021 2036 Methylene chloride 50 49 1 97 70-130 05/11/2021 2036 Styrene 50 54 1 107 70-130 05/11/2021 2036 1,1,1,2-Tetrachloroethane 50 50 1 99 70-130 05/11/2021 2036 1,1,2,2-Tetrachloroethane 50 49 1 98 70-130 05/11/2021 2036 Tetrachloroethene 50 47 1 94 70-130 05/11/2021 2036 Toluene 50 51 1 101 70-130 05/11/2021 2036 1,1,1-Trichloroethane 50 51 1 101 70-130 05/11/2021 2036 1,1,2-Trichloroethane 50 49 1 98 70-130 05/11/2021 2036 Trichloroethene 50 46 1 92 70-130 05/11/2021 2036 Trichlorofluoromethane 50 50 1 99 70-130 05/11/2021 2036 1,2,3-Trichloropropane 50 48 1 96 70-130 05/11/2021 2036 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 33 of 39 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ91963-002 Matrix: Aqueous Batch: 91963 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 48 1 95 60-140 05/11/2021 2036 Vinyl chloride 50 51 1 102 70-130 05/11/2021 2036 Xylenes (total) 100 100 1 103 70-130 05/11/2021 2036 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 98 70-130 1,2-Dichloroethane-d4 94 70-130 Toluene-d8 95 70-130 LOQ = Limit of Quantitation ND = Not detected at or above the DL N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 34 of 39 ICP-MS Metals - MB Sample ID: WQ90835-001 Matrix: Aqueous Batch: 90835 Prep Method: 3005A Analytical Method: 6020B Prep Date: 05/03/2021 0426 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony ND 1 2.0 0.50 ug/L 05/03/2021 1615 Arsenic ND 1 2.0 1.3 ug/L 05/03/2021 1615 Barium ND 1 5.0 1.3 ug/L 05/03/2021 1615 Beryllium ND 1 0.40 0.15 ug/L 05/03/2021 1615 Cadmium ND 1 0.50 0.13 ug/L 05/03/2021 1615 Chromium ND 1 5.0 1.3 ug/L 05/03/2021 1615 Cobalt ND 1 5.0 1.3 ug/L 05/03/2021 1615 Copper ND 1 5.0 1.3 ug/L 05/03/2021 1615 Lead ND 1 1.0 0.25 ug/L 05/03/2021 1615 Nickel ND 1 5.0 1.3 ug/L 05/03/2021 1615 Selenium ND 1 5.0 1.3 ug/L 05/03/2021 1615 Silver ND 1 1.0 0.25 ug/L 05/03/2021 1615 Thallium ND 1 0.50 0.15 ug/L 05/03/2021 1615 Vanadium ND 1 5.0 2.5 ug/L 05/03/2021 1615 Zinc ND 1 10 2.5 ug/L 05/03/2021 1615 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 35 of 39 ICP-MS Metals - LCS Sample ID: WQ90835-002 Matrix: Aqueous Batch: 90835 Prep Method: 3005A Analytical Method: 6020B Prep Date: 05/03/2021 0426 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 100 1 102 80-120 05/03/2021 1621 Arsenic 100 98 1 98 80-120 05/03/2021 1621 Barium 100 100 1 101 80-120 05/03/2021 1621 Beryllium 100 110 1 114 80-120 05/03/2021 1621 Cadmium 100 94 1 94 80-120 05/03/2021 1621 Chromium 100 96 1 96 80-120 05/03/2021 1621 Cobalt 100 95 1 95 80-120 05/03/2021 1621 Copper 100 99 1 99 80-120 05/03/2021 1621 Lead 100 100 1 103 80-120 05/03/2021 1621 Nickel 100 97 1 97 80-120 05/03/2021 1621 Selenium 100 85 1 85 80-120 05/03/2021 1621 Silver 100 100 1 102 80-120 05/03/2021 1621 Thallium 100 100 1 101 80-120 05/03/2021 1621 Vanadium 100 96 1 96 80-120 05/03/2021 1621 Zinc 100 88 1 88 80-120 05/03/2021 1621 LOQ = Limit of Quantitation DL = Detection Limit ND = Not detected at or above the DL N = Recovery is out of criteria J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 36 of 39 Chain of Custody and Miscellaneous Documents Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 37 of 39 �0 CD CD m D >v v C -c °' rn ID o CD N � r r N 0 ° C CD a- K N CD n d m V <, N 0 � m O° V 2L co cj) t N (O R V 0 CD N T N n V O w 0 E3 ace Arrltfcal i PACE ANALYTICAL SERVICES, LLC 106 Varrta a F'ainl 0r1we • Vlest CDlUMLI:a, G, 29172 TOIL? romp Kra. 800-701-�1700 Fax No. $(M-791•8171 wwwpacalabs.cam Number 1 !9 9 11 {'.lrs'ir Rapar�rooa'Irac' '�orra,afla�Fu� auo.+orra -~",~ ,�3,'rs5c �3r:T.g�ksk,SEpx,;ua_ ,V�a�(,grF.V�77,'!1'�P"7p41ro rs r'aed�dJ ` +I 4 4 I IzoCoda CO__ _ __.;!31%1 rV71Ked AWTFw Srn'r{ufbl�i i ��99:'rj�ii?ri �or�va Cufar6Sw 77.r.c : x uT { ? '� � L ,Rai �ks .' L ap" . 1L 1i s �-;adl nopa Clio W ;nffo,mm MQIG &W.} A PSI 2.11farrr ,f j4f S ic, r i 6rt i ' --- -- iTl 1 1111 Twyrprcrrod 7naa �ioglA'6dfi7,i9F 1�8�epmwrr�affrarer�e�,ra�A��[� :�,xiule Di+gLrt,� passe rY�a�d c�elfa� CG �M1o'�rne�s(,Q�n��71 . n 9ondard - nuarl f r.?`) Cl .I§wrn'olxM 'J Oi�ppo-`7rLVlai' J Hon H aR U Ffininahle U On intent LJ Palsal U UriHnoVAI f. n i5 cc by ppp�g��r#�yyy Tian: + 7..�" � � � rxwl ;mm _—• . Z fWOOQ Lbtd Lly owe Tire T ;7. RAY--rrfwl{f)y f�ll�tfyl•j 7FFH9 T,- .1 R:Y:r.;w.%,o Tfte 13iln j' LA806E O tr � � r�Ra Fwa h Y rl rr NoPe, kF somfQim arcs rerahvW Ina four Waww k.5 barn races# unless 0 ]9f 2lr2f7.,pi pnto 2ra mad. . �� Fkv3r ed on ks 'GYRalel }' s Mo ke Psak 1?eLOof brio —7C Yam_ DUTRl6tMO L- W -i TF.. & YLaLD ' Ncrarrq is kiaa'aroT 0-10 f'mrAcWs}, AVJiC-: ieloGu or Co,� uc" aawmenrm-rrbarVTWO &OY U) m W PACE ANALYTICAL SERVICES, LLC Salrrlpies lteeeLpt rha&INtISM) IME0018C-15) Re% sed:9;2912020 �e:kr JyPie�' ;ssi ing Authority: Pace ENS' - WCG-L Page 1 of 1 Sample Receipt CheeWst (SR ) lien[: OoDlorin5>ccta i bWdale, rrt{'l. ! fAJvw�.rrt1 i rlt : 1a11"MILI Means of rec4ipt: V Pace LSffnnnt j7UPS U lledEx El Other. ❑ Y Nil were uLi_srody �cals prescnr mn 'hc cooler? klifCUSLIPLky 17 Ye N _ � N'Ascals wcrc pre.wriL, wtrr Li7ew i3118 ;I irI Id u10.1I kwlrla 'Odgiiial H StLipl]:): I'll31 Qloriuo SMp lD: "�` Tested by.. �tia tennperature upon rc�,eipt/DeL' VOd ( kej) tmnplrLturr. Ligon re[eipi 'Mnlid SnapJCup ID: NA 1-6 f L_6 r(+ NA y MA oC N,4 INA eC NA jNA + C MMelht�d: RTvrn-jeT-AtLrte BL',l_k LIAgAkst Battles IR Chin ID: j _ IR Gun Corr=icn Fnctor: 2 °C MMR'thod of coo -wit, 0 Wet Ice ED I" NCICS ❑ 1)L ' Ice ❑ NOM ❑ Yes I ❑ N o 0T4A s. 1: reniperatur�,- Df Lmy cook? execcdcd G,0°C, WiL5 Pra]cct Manugw Nu ifitxl7 1'M was NtrAml b} -: phoilu f tiaisiJ i fate-du-[iwv (eirclz uric), Yes I Lj No vg IAA 4, Is the cortlmercial cmricr's packing slip attmficd to tlii� form? WIT Yes LJ No Ji_ WPre. proper ruslody proLmdLlres (rclinclufn11crWed? ,r -(es I DNO 6. Wcrc 5;:1mpk Os I:sted an the OOP:° ❑ YyiHNU J� sNo 7. Wciv 5anipir, IDs I'Stcd orsAll %viol; CoMtaihdrs? 3. Was 3Mllr.ctinn der.;& thr, li Si;d nn tlC CO [Z Yes Lj No 9. Wns oalivq' iun d4w & Urnc ]iA;;d un all sample 4urilairters? yet ❑ lqa I I}ir all rnnLai Kl F l.ahel inCnnYlMIM (M, da-e. dme) a see wish the C{lM 'r',-.4 No I I_ Wcrc Lms tki hn lirrk n ned listed ixi Lhc COC? ❑� Y::s ❑�Ncr 12. DId all sampIcs arrive is the prop,7 containers fcr each test vrWor in good condition ; Oobrokcar ]ids an, etc,)? [� Y,.k Alt, 13_ Was adaguam aarwp le vDlume available? s 4 --5 Iglu 14_ Wem D11 sample; received wiLbin % the haldfitg time c,' 46 hours, w1i ichever comes fir3t? - - U Yes No 15. W= atTy nrtt ks cmcaincrs missiriE 'cxcess {circk onc) saLnpIcs Not listcxi on COM �`f*- -No ❑NA 16- Foe• VOA irnd RSK-175.yttmpl'!srWere Wbblr5 present >"pe�L-.5i7jL (14"cw 6mnl in rJi 'eLeY) J11 any {ll'tILC VOA k'lLllS? 1C0s LJ No NA L7. Wcm all DRUr'mcta]slnutrimc sarlplcs rcrci%rcd at a pi-1 of-'Z? ❑ Yes Ll No Z N A 1 K. W= al I C ar idc samt pl cs L%ccc iv-od ac s pi I > ] 2 and sulfide sartl pies rwz:ivcd at a pli >= #' ❑-'as ❑No ❑1'VA ] _ Were a I I app i DaWe N H3Tl KN.cyani p acne 5.1, 4 _57n MInp es Toe Iesid--Ifd �hlodirl ° ' Yam. ❑ " NA ©I 20- W'em el iertl rorwrlcs�(requescs Q.t - regLL led Uutions, MSi SD desipdiom> etc—) L:ommly transcri6W from the COC into llic� cam mcrri scucion in L] MS? Yes i * AlL7 '21. W9.9 the rote n-,1"ber IWed on ?h� rantainPF Ifibel? IFyus, Quote # Sample Yreservatiall (i+'t'JSt be aamp:CLCd fur any 5ampk(s) ioc rrcctly prc9crvcC or %%-ith hcadspauc.) IiTime 5aMple(S) NA wvem received incorrerxly preserved andwere adjusted acma n sample recoiving wish MA r -_ m L of circle one: HN 03, H U, NaO H tr5i ng SK t+ '4 ofpvm vatian "4A....._... 1: mare tlinn one preservative is IweJed, please hkate in dso comm ants below_ ingly— Samples) rt were rcxmivpl with hubHzA>6 mn1 in diom r. Samples(s) rwn were race Ned mritll TRC > D, S mWL (If # 19 is fro) and wera adjusted a,:cordljigly in sample mce=v-11g with SiXliLIM 111iMilfaLe (Na?01) Wil.11 Shealy ID: Sly hrocdc JaL cis applied by: dRr',� Date, 44,1(00.1 Comrtlents� r Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 39 of 39