HomeMy WebLinkAbout4116_Guilford_WI_GFL_HighPoint_CDLF_LFG_FID1595838_20210806I PertR USE ONLY --it ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes ! No } Dec/Event #.
NC DENR I I Environmental Monitoring
Division of Waste Management - Solid Waste Reporting Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132.1, As such. these documents are
available far Inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
• Prepare one form for each Individually monitored unit.
Please type or print legibly,
Attach a notification table with values that altain or exceed NC 2L groundwater standards or NC 26 surface water standards_ The notification
must Include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-exisling
condilion, etc.).
Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limlts.
Attach a notiflution table of any methane gas values that attain or exceed explosive gas levels. This InClUdes any Structures on or nearby the
facility (NCAC 13B .1629 (4)(a)(i).
Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DVVM, Solid Waste
Section, 1646 Mail Service Center, Raleigh, INC 21699-1646.
Solid Waste Monitorin Data Submittal irtfOrmatioft
Name of entity submitting data (laboratory, consultant, facility owner):
Golder Associates NC, Inc. on behalf of High Point C&D Landfill
Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address:
Name; Darren Cox Phone; 336-852.4903
E-mail, decox@golder.com
NC Landfill Rule: Actual sampling dates (e,g.,
Fae ttty name: Facility Address: Facility permit # (.0500 or. 1600) October 20-24, 2006)
High Polnt C&D Landflil 5830 Riverdale Drive 41.16 1500 August 2. 2021
Jamestown, NC 27282
Environmental Status: (Check all that apply)
❑ Initialf8ackground Monitoring ❑ Detection Monitoring L _I Assessment Monitoring Lj Corrective Action
of data submitted: (Check all that apply)
Groundwater man itoring data from monitoring wells 0
Groundwater monitoring data from private water supply wells ❑
Leachate monitoring data
Surface water monitoring data ❑
Methane gas monitoring data
Corrective action data (specify)
Other(speclfy)
Notification attached?
❑ No. No groundwater or surface water standards were exceeded.
Yes, a notification of values exceeding a groundwater or surface water standard is attached. It Includes a list of groundwater and surface water
monitoring points, dales, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and
preliminary analysis of the cause and significance of any concentration.
Q Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dales, sample
values and explosive methane gas limits.
Certification
To the best of my knowledge, the Information reported and statements made on this data submittal and attachments are true and correct.
Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas
levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
David Y. Reedy II, PG Senior Hydrogeologisl 336-852-4903
Title (Area Code) Telephone Number
Affix NC Licensed! Professional Geologist Seal
��d�rt�raaac�F.�#r
�-' tta WWI*
Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, NC 27407
Facility Representative Address
PE C-2862; PG C-399
NC PE Firm License Number (if applicable effective May 1, 2009)
Revised l512009
4
WE
GF
e n v i r o A m i?n t A I
August 6, 2021
Ms. Jaclynne Drummond, Hydrogeologist
Department of Environmental Quality, Division of Waste Management, Solid Waste Section
2090 US Highway 70
5wannanoa, North Carolina 28778
jaclynne.drummond@ncdenr.gov
RE: METHANE MONITORING RESULTS AND NOTIFICATION OF EXCEEDANCE —
AUGUST 2021 MONTHLY EVENT
Wl HIGH POINT CONSTRUCTION AND DEMOLITION LANDFILL AND RECLAMATION
FACILITY, PERMIT NO. 41-16
Dear Ms. Drummond,
WI High Point Landfill, LLC, is submitting the enclosed methane monitoring results and
notification of exceedance for the August 2021 monthly methane monitoring event at the above -
referenced facility_ If you have any questions, please contact me at (724) 244-9511.
Sincerely,
WI High Point Landfill, LLC
Joseph Santangelo
Joseph Santangelo
Regional Environmental Compliance Manager
Enclosure
C: Dusty Reedy, PG, Golder Associates NO, Inc., 513 Oak Branch Drive, Greensboro, North
Carolina, 27407, 336-852-4903, dreedy@golder.com
Travis Hitchcock, 3301 Benson ❑rive, Raleigh, North Carolina, 27609.
(travis.hitchcock@gflenv.com), (letter only).
Bryan Wuester, Regional Landfill Manager, 7434 Roseboro Highway, Roseboro, Sampson
County, North Carolina 28382, Bryan.Wuesterl@gflenv.com
Seth Heath, General Manager,5830 Riverdale Drive, Jamestown, North Carolina 27282,
seth.heath@gfienv.com, 336-886-3560
1236 Elon Place High Point NC. 27263
Tel.:336-668-3712 1 Fax:336-482-3061 I gflenu.com
kCOLDEP
MEMBER OF W5P
August 6, 2021
Joseph Santangelo, Regional Environmental Compliance Manager
GFL Environmental Inc.
1192 McClellandtown Road
McClellandtown, Pennsylvania 15458
jodeph.santangelo@gflenv.com
Project No. 2013788121.701
METHANE MONITORING RESULTS AND NOTIFICATION OF EXCEEDANCE -- AUGUST MONTHLY EVENT
FOR 2021
WI HIGH POINT CONSTRUCTION AND DEMOLITION LANDFILL AND RECLAMATION FACILITY, PERMIT
NO. 41-16
Dear Joe,
Attached are the results from the August 2, 2021, monthly methane monitoring at the above -referenced facility for
your files. As shown on the attached Landfill Gas Monitoring Data Form, methane was detected at compliance
monitoring point LFG-2A above the lower explosive limit (LEL) during this monthly methane monitoring event.
A Landfill Gas Remediation Plan (LFGRP) was submitted to the North Carolina Department of Environmental
Quality (NC DEQ) by Smith+Gardner on July 26, 2021 and was approved by the NC DEQ on August 2, 2001. As
proposed in the LFGRP, the installation of vent in the berm adjacent to LFG-2A and re -grading the area to
promote better drainage began on July 23, 2001, If you have any questions or concerns, please contact us at
336 852-4903.
Sincerely,
Golder Associates NC, Inc.
David "Dusty" Y. Reedy II, PG
Senior F tydrogeo)ogist
17
(i(•,—
Rachel P. Kirkman, PG
Principal and Senior Consultant
Golder Associates NC, Inc.
5B oak Branch Drive, Greensboro, North Caroline, USA 27407 T: +t 336 852-4903 F: +t 336 652-4904
Engineering Lic. No. G-28621Geology Lie. No. C•399
Golder Associates NC, Inc. is a Ilcensed user of the Golder Irademark, and an associated operating entity.
Golder and the G logo are trademarks of Golder AsSDGIate6 Corporation. golder.Com
Joseph Santangelo, Regional Environmental Compliance Manager
Projecl No 2013788121.701
GFL Environmental fnc August 5, 2021
CC: Seth Heath, General Manager,5830 Riverdale Drive, Jamestown, NC 27282,
Seth.heath@gflenv.com, 336-886-3560
Bryan Wuester, Regional Landfill Manager, GFL Environmental, 7434 Roseboro Highway, NC
28382, Bryan wuester@gflenv.com (Electronic Copy)
Travis Hitchcock, Region Vice President. GFL Envrionmental, 3301 Benson Drive, Suite 601,
Raleigh, NC, 27609, travis.hitchcock@gflenv.com. (Electronic Copy)
Attachments. Boundary Gas Probe Monitoring Log — August 2, 2021
Site Location Map
Calibration Forms
GRLDER
NC Division of Waste Management - S01id Waste Section
Landfill Gas Monitaring Data Furrn
Notice: Tins for nr and any H{%rntatfor+ arrdtlred to it are "Public Records" as defined 1n IVC Generrl1S1,rm fe 132-1. As such, these documents are
awnhrhle for orpectiou and exatninalion by arty person cipan request fiV(' General 5tanue 132-6).
Facility Name: Waste Industries of High Point C&D Landfill Permit Number: 41-16
Sampling Date: 08/02/2021
Sample Collector Name & Position:
Landfill Rule (.0500 or.lb00): '0500
Nicolas Tejeda-Torres, Geologist
Gas Meter Type & Serial Number: GEM 5000
Field Calibration Date & Time:
08/02/2021; 11:15
Field Calibration Gas Type (15115 or 35150
Gas Meter Pump Rate: 300 cc/min
Gas Meter Calibration Date: 08/ 18/2020
15/15 Field Calibration Gas Canister Expiration Date: 9/25/2024
?7° F 29.07" Cloudy, winds ENE 12mpn
Ambient Air Temperature, Barometric Pressure (in. nr mm !lg): Weather Conditions:
Instructions: !Under "Location or LFG Well", list monitoring well 0 or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing,. Report methane readings as both % LEL and % CH4 by volume.
Convert % (714 (hy volume) to % LI-L as fallaws: % methane (fry volume)120 = % LEL
*Hydrogen Strfflde (H2S) gas monhor•ing may be required,for Construction & Demvlilivn Lunclflllx (CDLP. J. See
individual pertnil conditions and or facility LIT; monitoring plan.
I,c>Lat1oil I
l.l�ti Well I V
Sample
Tube
Purge
Time ni
Day
Time
Puln td
Pe
Oec)
Initial
u
l6 L.EL.
SiuNlized
a fq LI=L
%C114
(volume)
o
/o G2
(volume)
9e C'(}2
ivnitime)
e
fa flzS'
(volwne)
1VpTF.S
Scalehouse
12:00
90
0.0
0.0
0.0
21.3
0.0
0.0
Maintenance
12:05
90
0.0
0,0
0.0
21.1
0.0
0.0
Break Room
12:09
9D
0.0
0.0
0.0
21.1
0.0
0.0
LFG-1
12.29
90
0.0
0.0
0.0
20.0
0.0
0.0
LFG-2
12:20
90
0.0
0.0
0.1
19.7
1.2
0.0
LFG-2A
12:22
90
206
206
10.3
14.4
9.7
0,0
LFG-3
12:14
90
0.0
0.0
0.1
15.3
20.9
7.4
1.0
LFG 4
12:12
90
0.0
0.0
0.1
0.1
0.0
LFG-5
12:36
90
0.0
0.0
0.2
17.7
2.9
1.0
NOTt': (/needed. poach additional data forms to include adliitrarnd i f (i airmiyori rg dote locations for the fauhry.
A(-Tio,N LEVELS: Methane: �1.25by vulume (inside xlrut:tures) AND >5%hy volume (at facility boundary)
Hydrogen Sul Fide: }1 % by volume ( inside struclures) AND r4% by vuluroe (at racility buulidztrv)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there sire significant penalties for making any false statement, representation,
or certificatiori i the po tbLlity of a line and imprisonment.
- Geologist
SIGNATURE � TITLE
Revised -March fi, 2017
71
m
08L
rn
i
'Ems
801
go
FACILITY
HIM
I
RUNS
• 016 6 L i
❑SW-1 SURFACE WATER MONITORING POINT
0, / LFG-1 LANDFILL GAS MONITORING WELL LOCATIONS
{� 009
O \ ABM-1 BENCH MARK a1
i
- o i SB-1 SEDIMENT BASIN
O
800.9 -
.809. Q .9 790 \ \ \ ! r NOTES
a 1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET
� � l
\\_ 2. DRAWING BASED ON SITE PLAN PLAN PREPARED BY JOYCE ENGINEERING, INC DATED
JULY 7, 2004.
3. UPDATED TOPOGRAPHY PROVIDED FROM AERIAL SURVEY PREPARED BY COOPER AERIAL
W
\ SURVEY COMPANY, DATE JANUARY 08, 2019.
i -
7
E_ \ I 0 200 400
0
SCALE FEET
CLIENT PROJECT
(WASTE INDUSTRIES OF HIGH POINT, INC. WASTE INDUSTRIES OF HIGH POINT CONSTRUCTION AND
\ DEMOLITION DEBRIS LANDFILL AND RECLAMATION FACILITY
GUILFORD COUNTY, NORTH CAROLINA
CONSULTANT YYYY-MM-DD 2021-06-22 TITLE
PREPARED SIB METHANE MONITORING LOCATION MAP
G 0 L D E R DESIGN DYR
MEMBER OF WSP REVIEW DYR PROJECT No. HAC Rev. DRAWING
1, APPROVED RPK 20-13788121 0
ENVIRO-EQUIPMENT, INC.
LANDTE,C GEM 5000 Plus CALIBRATION DATA SHEET
Serial Number - Date Inspector �i
Time.'Date Dot;cry Level Memory Cleared 1'unll) t�flulls
Gas Alarms: c1•1., - 100.0"Y�r - , � CU; = IUU.V",
Zero I'ransducers Pump[ Rate lf
low ��' trtY\ I Vacuum Tested To 80" 1[20
Cofibrrrfrarr Check (Pi�rlbnned (r Room Tompe)-e o-vi
Calibration Gas
Calibration Gas
Lot -Number
f:xpir_ation
Reading
Conc$rtiiration
Pure N2
'Zs
'
211
I.01v CEI.r
4 5 7"
Low02
�•�v
� T2,
74
I I lgh 02
20.9%
NIA
N: A
•jig, unrey dcp�rtiJs upon calit�ratlnn range: 15%-FS mnw for CH; & f0r os, 0%,FS l'ur 1 IjS. ;mcl 1 u1�.. oI,rc.ulurg 16r(.1)
INSPECTOR'S MAINTENANCE NOTES
LEI GF i4I M Past Car Firm M I2 —
CERT'ilFIC.ATMOJV
OF CALIBRATION
r No.66916
Date Of Calibration: 18-Aug 202f}
Issued by.: QED•Environm�ntal Systems Inc.
Van Accredited results'
QEU�
Ctrtificate Number: G504637_9/39830
Pressure'Transducers' Inches of water column
Transducer Certified (Low) Reading (Low) Certified (HIgM) Reading (High) Accuracy
Static
0" 0100"
40" 39.99"
2.0"
Differential
0,00"
4" 4.00"
0.7"
Barometer mbar
Reference
Instrument Reading
0983 mbar 1 29.04 "Hig
0983 mbar 29.04 "H
As received gas check readings:
Methane 04 ,
Certifled Gas % InstrumenbRed'dln %
5.9
15.0 '. 9 16.5
50.0 51.9 �+
Carbol) Dioxide CO2 -
CertEfied'Gas 96 +
' Instrument Readin %
4.9
4.9
15.0 4
14,7
50,0
481
0XViREen 02
Certified Gas % 'Mstrume oWdln %
2M
IL - As received Gas readings recorded at: 30.4 °C/86.8 °F
4
As received Barometric Pressure recorded ati 21.4 V70S-F,_
Date of Issue I XB Aug 2020 w Approved By Sigmtory _ Dorc McCarty
taboratoryIAspect ion
�i -
The calibration results pubilshed In thiscgEtlflctite were obtained using equipment capAle of producing results that are traceable through MIST to the International System of
Units {sl�. 6ert1f cation only applies to rlsults shown. This certificate may not be reproduced other than In Full, except with the prior writterl ap6roval of the Issuing laboratory.
ftbrmk+a Inata m a07 MC raslnnea: I07-, +• . ► _ - fare 2 oT,x,t 4PoISLNAN]S�r-I.I
F ' - www.gedenv,com (800) 624-20'26 Info@gedehmom QED Environmental Environmental Systems Inc. 23.55.6ishop.�Cfr;le West, Dexter, MI 48130
CERTIFICATION.--,.
OF CALIBRATION .. ID
No.66916
Date Of Calibration: 18-Aug-2020 - 'Certiflcate Number: G504637_9/39830'
.Issued by. QED Enyirortmental Systems Inc.. '
Custombr: ENORO EQUIPMENT INC
11180 DOWNS RD PiNEVILLE,•NC 28134 USA -
Description: Landtec Gas Analyzer
Mader: GEM5000
Serial Number: G504637
Accredited Results;
- Methane GM4 -
Certified Gas 96
Instrument,Readin 96
uncertaint %
0.42
15.0
15.1
1..0.66
50.0
49.
1.03
" Carbon Dioxides COx
Certified Gas % •
Instrument iieadfin
Uncertai , 96
- 4.9
4.8
0.43 '
1510
14:8
40.71
_
' 50.0
49,9
4 1r.19
Lox"en 02 �. -
- Certified Ga %
Instrument Iteadini 96 ,'
Uncerta n 96
F
20.9..
21.0
.-Gas' cylindersare traceable and detalls can -be provided It -
requested.
CH4, CQ2 readings recordedlat: 30.4 "C/86,8'Fr rt Sarometricpressure: '098311Hg/29.04 °Ng µ
02 readings recorded at: 2LVC/705'F
Method of Test : The analyzer is calibrated in a temperature controlled chamber using a series of reference
gases, in- compliance with procedure I5P17. Y
The reported expondedtinrerlaintyi is (based on u stdndard uncertainty multiplied by a coverage factor of k-2,
providing a level of confidence of approximately 9-q%. -The uncertainty evaluation has been carried -out in accordae2ce
with NrSTregvirerrients.
me calibration results publlshed In this certificate were obtained using equipment capable of producinQYesulls that are traceable through NISI to the Intecnatlonal System of
Units (Sil, Ortlficatlon only applies to results shown. This certificate may not be reproduced other than In full, exceptwith the prlor written approval of the Issuing laboratory.
• Odibrae oa laslnnee, t117 -1OC tnsLwcc t07' PACE l or2I4,P41XNANKr•I.1
. 0
www.gedenv.Co•m ' (800) 624-2026•• - lnfa@geden►r.com
QED Enviranme' ntal Systems -Inc. 2355 Blsh�ap Circle West{ Dexter, MI 48130 -