Loading...
HomeMy WebLinkAbout22070_RSC Indian Trail_SIR_20210807 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 07/16/2021 12:10 PM I. Inspection Information Date & Time: 07/08/2021 1:17 PM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter Other Personnel: Patrick Pierce-Selwyn Property Group, Steve Hart H&H Location: Lat: 35.0618, Long: -80.65207, Brownfields Inspection Report: RSC Indian Trail, 22070-18-090 07/08/2021 1:17 PM Page 2 of 7 II. Project Information Number: 22070-18-090 Name: RSC Indian Trail Address: 600 Radiator Rd City: Indian Trail County: Union III. Environmental Current Use of Property: Industrial Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Not Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: N/A Summary: N/A Summary: Single story brick warehouse type buildings. Main inspection centered on eastern site building. Although warehouse is a single structure, it consists of 6 "buildings", constructed in different phases with apparently separate slabs. Past chemical solution manufacturing and containerizing of products took place in Buildings 1 and Building 2 located on northeast portion of building. Summary: N/A Brownfields Inspection Report: RSC Indian Trail, 22070-18-090 07/08/2021 1:17 PM Page 3 of 7 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A; Monitoring wells are present on-site, but were not observed during the site inspection. Previous sampling identified a risk to site occupants within Buildings 1 and 2. Buildings 1 and 2 were not in use at the time of the Site Inspection and were temporarily closed off from other buildings within the warehouse. This was done by sealing former forklift openings with drywall (photos 2 and 3), and keeping the pedestrian doors, and remaining former forklift doors connecting Building 2 to Buildings 3 and 5 closed. Due to potential fire or other emergencies, it was decided that these doors should not be locked. Air gaps were visible around steel forklift doors, and below steel pedestrian doors connecting north end of Building 1 to Building 5 and Building 2 to Building 3. Brownfields Inspection Report: RSC Indian Trail, 22070-18-090 07/08/2021 1:17 PM Page 4 of 7 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Ramp to forklift door between Building 5 and Building 2. Gaps around door were visible during inspection. Tenant would like to remove door, install clear plastic strip curtains at this location, and at forklift opening between Buildings 2 and 3. Conducted site visit to evaluate eastern site building for sampling to accompany occupancy of the building. The western site building/exterior of the Site was not included in the inspection. As discussed previously, Buildings 1 and 2 (which had indoor air PCE impacts above non-residential IASL's) were not in use at time of inspection. Process piping has been removed between Buildings 1 and 2 with the exception of the sprinkler system piping. Brownfields Inspection Report: RSC Indian Trail, 22070-18-090 07/08/2021 1:17 PM Page 5 of 7 Photo 2: Example of steel framed dry-wall "wall" constructed in forklift opening Photo 3: Close up of dry-wall "wall" constructed to prevent VI migration between buildings. Steel framing visible through gap at edge of brick. Brownfields Inspection Report: RSC Indian Trail, 22070-18-090 07/08/2021 1:17 PM Page 6 of 7 Photo 4: Voids in brick wall between Building 1 and Building 2 where piping removed. Piping not removed between other rooms. Photo 5: Gap below steel door connecting north end of Building 1 to portion of Building 5 that wraps around northwestern corner of Building 1. Brownfields Inspection Report: RSC Indian Trail, 22070-18-090 07/08/2021 1:17 PM Page 7 of 7 Photo 6: Sealing of former pits performed in Building 2 since last sampling event. Photo 7: Office space utilized in Building 4. Rolled up bay doors present in Buildings 3-6, in addition to operating wall fans observed in Buildings 2-4, with a large floor fan operating in Building 5.