HomeMy WebLinkAbout4116_Guilford_WI_GFL_HighPoint_CDLF_LFGRemediationPlan_FID1594893_20210726DocuSign Envelope ID: 095A807F-F82D-4431-B9F0-44AE5C2DE9F4 SMITH GARDNER July 26, 2021 Mr. Jaclynne Drummond Hydrogeologist Compliance Hydrogeologist NCDENR DWM Solid Waste Section 2090 US Highway 70 Swannanoa, North Carolina 28778 AMESS TEr WEB 14 N. Boylan Avenue, Raleigh NE 27003 919.828.0577 www.smithgardnerinc.com RE: Landfill Gas Remediation Plan WI High Point C&D Landfill (NC Solid Waste Permit No.41-16) Jamestown, North Carolina Dear Ms. Drummond: On June 2, 2021 Golder Associates NC, Inc. (Golder) sent a Notice of Exceedancel to NCDEQ in response to an exceedance of the methane lower explosive limit (LEL) at compliance monitoring point LFG-2A during the second quarter monitoring event for WI High Point C&D Landfill INC Solid Waste Permit No. 41-16). On behalf of WI High Point Landfill, LLC and in accordance with 15A NCAC 13B .0544(d)(3)(C) S+G submits the following remediation plan in response to the exceedance for your review and approval. Site Information South of LFG-2A is a perimeter berm, which serves as a visual buffer for the site. Standing water is frequently present south of the berm, between the berm and the Reclamation Facility. Historical landfill gas (LFG) data and data from the recent soil vapor survey shows that presence of gas is limited to the area south of LFG-2A, between the berm and reclamation pad. Additional Investigation Following detection of the exceedance, Smith Gardner, Inc. (S+G) performed a limited soil vapor survey around LFG-2A where the exceedances occurred and investigated potential remedies. The location of the soil gas survey investigation and the results are shown on Figure 1. This investigation indicates that landfill gas is detected in limited areas of this portion of the site. On July 23, 2021 an approximate 100-foot-long trench, 8- to 10-foot-deep was excavated at the midpoint of the berm to inspect the berm and underlying soils. The location of the trench is included on Figure 1. As a result of the investigation organic debris, including soils and stumps, was encountered. r Notice of Exceedance Letter from Darren Cox, Rachel P. Kirkman, P.G. (Golder) to Jaclynne Drummond (NCDEQ), Dated June 2, 2021. DocuSign Envelope ID: 095A807F-F82D-4431-B9F0-44AE5C2DE9F4 Ms. Drummond July 26, 2021 Page 2 Remediation Plan The presence of organic debris and frequent standing water in the area is believed to be a primary source of the gas within LFG-2A. As a result, the proposed remediation plan includes: removal of the organic matter encountered during the trench excavation; installation of a fabric -wrapped 2-foot-deep gravel column and perforated PVC stand -pipe within the trench to vent any gas; and grading of the area between perimeter berm and reclamation pad to promote drainage. As the proposed system is installed and evaluated post -construction, additional remedial actions may be recommended as necessary. Remediation Schedule The anticipated schedule for this remediation plan for the facility is presented below: • Within 30-days of approval of this plan (weather permitting) construction activities will be completed; A report summarizing the field activities for LFG passive vent installation will be submitted to NCDEQ within 60 days of completion of all field work. This report will include construction inspection reports and as -built figures detailing the work; and • Monthly monitoring and reporting of compliance monitoring point LFG-2A to NCDEQ upon completion of each monitoring event until two (2) consecutive monitoring events show methane concentrations below the LEL. Based upon long-term monitoring of the proposed system, additional phases of remedial action may be proposed in the future as necessary. Record Keeping Program The facility shall maintain documents relating to LFG monitoring in an operating record located at the office of the General Manager or his designee. These records will be presented upon request to DWM for inspection. DocuSign Envelope ID: 095A807F-F82D-4431-B9FO-44AE5C2DE9F4 Ms. Drummond July 26, 2021 Page 3 If you have any questions, or require additional information, please contact us at your earliest convenience at 919-828-0577 or by e-mail (address below). Sincerely, SMITH GARONER, INC. DocuSigned by: B9779EBA711F488. Joan A. Smyth, P.G. Senior Hydrogeologist 0oan(asmithgardnerinc.com Attachments CC: Seth Heath - GFL Bryan Wuester - GFL Travis Hitchcock - GFL CARO SEAL u1Docuu�Siignedby:028426 358C21 E64007440... W. Michael Brinchek, P.E''+,#`qF�*•`�4 Senior Project Manager "+8+5101�1*/26/2021 mike@smithgardnerinc.com Joseph Santangelo, P.G. - GFL Rachel Kirkman, P.G. - Golder Dusty Reed, P.G. - Golder H:\Projects\WI High Point Landfill W&D)\WIHIGHPOINT 21-3 (LFG-2A Gas Remediation Plan)\WI High Point Road LFG Remediation Plan - Draft.docx DocuSign Envelope ID: 095A807F-F82D-4431-B9F0-44AE5C2DE9F4 This page intentionally left blank. DocuSign Envelope ID: 095A807F-F82D-4431-B9FO-44AE5C2DE9F4 \ i� LEGEND \ 0% CH4 @ -8' bgs81 EXISTING 10' CONTOUR O TRENCH LOCATION � Probe refusal (SEE REFERENCE 1) I � -3' J z m W � / I 1 _ _ _ _ _ _ _ / / Exposed Rock y- 58.9% CH4 p�) 1 bgs (Rock) EXISTING 2' CONTOUR N z z Z _T — — 0.1 % CH4 -LFG-1 \ �— - — — .... _._ �. z \ APPROXIMATE PROPERTY L0.1 % CH4LFG-2 O\\ I \ " ® E z S (SEE REFERENCE 2) ll SEDIMENT 1 / 13 7 �� .8 \ LFG-3 0.6% CH4 Samm 99 ���J—��� 200-FOOT BUFFER BASfi4�-L .811.0 I �I \\I 5•_ / — — PERMITTED WASTE LIMITS — _— — 795. , @10.5' b g // / r "810.8 20.8% CH4 s III I Z Probe refusal LFG MONITORING PROBE _ _ ' ��Tr (�j 1 8 (SEE REFERENCE 3) }-- ; — - (Rock) @ -2-3 bgs , .8103 � IIII \ III \ Probe refusal I x \\\ T (Rock) @ —8" bgs RECLAMATION F CIUTY \\ 8 m .r�(( x811.8 =IIII j\+ v 8,o.z 11l"Ill 810.4 I \\ \ FACILITY AND \\\\ PROPERTY en \ LFG— REFERENCES: 1. EXISTING TOPOGRAPHY FROM AERIAL SURVEY DATED JANUARY 6, // �,� _ aa_ l / I J I I II I I \ EL } IIII IIII I I \\ \ BOUNDAR ONn \ \ \ \ \ a � 2018 BY GEODATA CORPORATION, ZEBULON, NC WITH FIELD SURVEYS //� ///1 — — ��/ / J x8,,., EC DATED JANUARY 18, 2019 BY SURVEYING SOLUTIONS, P.C. i / / l / /// /// l I �IVT / a \ I \ I z — 2. FACILITY PROPERTY LINE REFERENCE: SURVEY BY MARK TERRY AND �// IIII j// j// j j jl/ x8os.7 %810.7 x ASSOCIATES, INC., DATED MAY 15, 2001. / / // / /// // j / J \ SITE EN I / - j 97 \ / \ NCE a z / / u 3. MONITORING LOCATIONS AND SPRINGHEAD LOCATIONS FROM DRAWING �� j / / CA S A / / / /// / / / "ENVIRONMENTAL ALEHOUSE \ 7ss.9 0 \ Z LL MONITORING PLAN", SHEET EP-5, DATED 12/19/06; /� o l o / - \ 1 \ MAINTENANCE / \ s O I I \ ONTA/NE BUILDING AND STORAGE AREA PIEZOMETER LOCATIONS FROM DRAWING "BORING, PIEZOMETER, AND / / / /// a s.6 808. / / / / / �� 8, 0.z MONITORING WELL LOCATION MAP", SHEET DH-1, DATED 4/13/07, / �/ J/�/ / // l% \� •8,0. / 848.3 / / / / \ o U' a cn Q ° z — — — PREPARED BY GOLDER AND ASSOCIATES, GREENSBORO, NC. i/ , IIII J ( v J �) �� — I — — _ _ _ _ ADDITIONAL POINTS FROM FIELD SURVEY DATED 3/18/16 BY ,L/1 \ — — — _ — _ _ _ — — ` — SURVEYING SOLUTIONS, YOUNGSVILLE, NC. , < G-5\ \ \ \ \ \ a a Z = w r_ / / T- I ,8a4. \ \ WASTE LIMITS w cj 0 a o J ?J1111//Illj 603. It 803.3 X t Il l(aStiE \\ \ //i f YN T ^\I1 \-780/ /i /\ P // i 11/I /� SE �80,.4 — \ \ RE) 9. o R� _ QSE� /� �. HA—� 800 �/ ✓.� _ \ P -3 b < m Boo _ V781. r //rir/irar //i � �/ / �i�J ► 11 IIIIJ Illll I/ I �s / �\ >$o =�� / i / �� 860 ////� /j / s�1 � � S ({/)ll I(I)Ir III I / ,� i \ _ i �\ /� / / � /� l: � \ /ll IIlI� 15 II I j / l (1 so�/�\—L-„% ` od 1,,"oq/////// I l �l l llJI 783.4\ — — f Y° �� / // / / 1 r/ — H SF{5 \ �� �� \ \ o _ HA-3 f ITUR )� ,I ' (FU \ 787.7 1 \ \ \ \ �\\ o w I I 780. / \ \ a DocuSign Envelope ID: 095A807F-F82D-4431-B9F0-44AE5C2DE9F4 This Page Intentionally Left Blank