HomeMy WebLinkAboutNCS01456_INSP_20210423FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 1 of 2
UNIT TYPE:
Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Forsyth
Closed MSWLF HHW White goods Incin T&P FIRM X PERMIT NO.: NCS-01456
CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE
Date of Site Inspection: 04/23/2021 Date of Last Inspection: .
FACILITY NAME AND ADDRESS:
Mr. David Welch Straight Flush Septic 1959 N. Peace Haven Rd., Suite 171
Winston-Salem, NC 27106
GPS COORDINATES: N: NA E: NA
FACILITY CONTACT INFORMATION:
Name: David Welch Address: Same as above Telephone: 336-970-0502
Email address: info@straightflushseptic.com
PARTICIPANTS: Chester Cobb (DWM) and David Welch STATUS OF PERMIT: Active EXPIRES: 12/31/2021
PURPOSE OF SITE VISIT: New Vehicle STATUS OF PAST NOTED VIOLATIONS: N.A.
OBSERVED VIOLATIONS:
NONE
The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules.
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 2 of 2
ADDITIONAL COMMENTS
1) Pumper vehicle(s) inspected:
TRUCK LICENSE PLATE # VIN # TANK CAPACITY (gal)
KH-6577 5PVNJ8AV9M5T51171 1,400
2) The firm name, town name, phone number, and firm permit number were on both sides of the pumper
vehicle. The letters were three (3) inches in height or greater. The lettering was distinguishable and not
blocked from view. The lettering on the pumper vehicle meets the requirements of 15A NCAC 13B
.0835(b).
3) The tank on the pumper vehicle was made of steel and affixed to the frame of the truck as per 15A NCAC
13B .0835(a)(1).
4) The valves appeared to be in working order and closed as per 15A NCAC 13B .0835(a)(2). Caps present
on hose ports.
5) Access ports on tanks appeared to be in good repair and sealed as per 15A NCAC 13B .0835(a)(3).
6) No leaks noticed from the tank or hose ports. However, some septage was notice on the side bed
around the tank for which the flexible hose was laid on. Rule 15A NCAC 13B .0835(a) states “Vehicles
used for the transportation of septage shall be operated and maintained to prevent leaks and spills of
septage…” Please ensure that there is no septage remaining in the hose that will spill out onto the bed
when placed back on the truck. It may be worthwhile to invest in some caps or plugs for the hoses.
7) The pumper vehicle passes inspection.
Driver side of pumper vehicle. Passenger side of pumper vehicle.
Please contact me if you have any questions or concerns regarding this inspection report.
____________________________________________ Phone: (919) 707-8283 .
Chester R. Cobb, Environmental Program Consultant
Division of Waste Management, NCDEQ Regional Representative
Sent on: X Email Hand delivery US Mail Certified No. [ _]