Loading...
HomeMy WebLinkAboutNCS01298_INSP_20210615FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 3 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Nash Closed MSWLF HHW White goods Incin T&P FIRM X PERMIT NO.: NCS-01298 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE Date of Site Inspection: 06/15/2021 Date of Last Inspection: . FACILITY NAME AND ADDRESS: Phillip Briley and Jerry Adams Carolina Pump & Sewer Service, Inc. 900 South Church Street Rocky Mount, NC 27803 GPS COORDINATES: N: NA E: NA FACILITY CONTACT INFORMATION: Name: Phillip Briley Address: PO Box 543 – Nashville, NC 27856 Telephone: 252-972-2900 Email address: cnelms@essgenerator.com PARTICIPANTS: Chester Cobb (DWM) STATUS OF PERMIT: Active EXPIRES: 12/31/2021 PURPOSE OF SITE VISIT: New Vehicle STATUS OF PAST NOTED VIOLATIONS: NA OBSERVED VIOLATIONS: NONE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 3 ADDITIONAL COMMENTS 1) Pumper vehicle(s) inspected: TRUCK LICENSE PLATE # VIN # TANK CAPACITY (gal) YA148170 2FZACGBS57AY09711 2,800 2) The required information of Firm name, town name, phone #, and permit # was on both sides of the pumper vehicle. Each letter of the required information was greater than three (3) inches in height. The lettering was distinguishable and not blocked from view. The lettering meets the requirements of 15A NCAC 13B .0835(b). See pictures below. 3) The tank is made of steel and affixed to the frame of the truck as per 15A NCAC 13B .0835(a)(1). 4) The valves appeared to be in working order and closed as per 15A NCAC 13B .0835(a)(2). Caps present on ports. 5) Access ports were closed and properly sealed as per 15A NCAC 13B .0835(a)(3). 6) No leaks noticed as per 15A NCAC 13B .0835(a). 7) Truck in compliance with the Septage Rules. 8) The letters for the Firm Name are starting to peel on the first septage pumper vehicle, License Tag # YA120348. Received email from Cathy stating that “Phillip has already got the man lined up to replace the lettering on the first septic truck.” Driver side of pumper vehicle. Passenger side of pumper vehicle. The letters for the Firm Name are starting to peel on the pumper vehicle with tag # YA120348. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 3 of 3 Please contact me if you have any questions or concerns regarding this inspection report. ____________________________________________ Phone: (919) 707-8283 . Chester R. Cobb, Environmental Program Consultant Division of Waste Management, NCDEQ Regional Representative Sent on: X Email Hand delivery US Mail Certified No. [ _]