HomeMy WebLinkAboutSLAS1013_PERMIT_RENEWAL_20200604 Facility Permit No.: SLAS-10-13 Robinson’s Septic Tank Cleaning Permit to Operate June 4, 2020 Page 2 of 4
CONDITIONS OF OPERATING PERMIT
1. This permit shall become void if the soils fail to adequately assimilate the septage and
shall be rescinded unless the site is maintained and operated in a manner which will
protect the assigned water quality standards of both surface and ground waters.
2. This site shall be operated and maintained in accordance with the nutrient management
plan submitted by Ryan Hewett and approved by the Division of Waste Management.
The 18.9-acre site is divided into six fields known as Field 1 (4.8 acres), Field 2 (4.3 acres),
Field 3 (0.9 acres), Field 4 (2.4 acres), Field 5 (2.1 acres), and Field 6 (4.4 acres). All fields
will be planted in millet in the spring (May – June) and cereal rye in the fall (September
– October) of each year. The millet and rye shall be harvested as hay for animal feed.
The 30-day waiting period between the last application of septage and crop harvest shall
be met by rotating septage applications between the six fields. All discharges shall be at
locations on the site consistent with the crop rotation in the approved plan.
3. This site shall be operated and maintained in accordance with the erosion and runoff
control plan submitted by Ryan Hewett in such a manner as to prevent the migration of
wastes off the designated waste receiving site. The required buffer area around each
field shall remain established in permanent vegetation (trees, bermudagrass, etc) or
planted in millet or cereal rye. Any site improvements noted in the plan must be installed
within 30 days of plan approval. The installation of groundwater monitoring wells shall
be required as deemed necessary by the Division.
4. The issuance of this permit does not preclude the Permittee from complying with any
and all statutes, rules, regulations, or ordinances that may be imposed by other local,
state, and federal government agencies which have jurisdiction. It is the responsibility
of the Permittee to be in compliance with the Federal Regulations listed in the Code of
Federal Regulations, 40 CFR Part 503.
5. This permit may be modified or reissued at any time to incorporate any conditions,
limitations and/or monitoring requirements the Division deems necessary to adequately
protect the environment and public health.
Facility Permit No.: SLAS-10-13 Robinson’s Septic Tank Cleaning Permit to Operate June 4, 2020 Page 3 of 4
6. This site is only permitted for the land application of domestic septage. The pH of
domestic septage shall be raised to 12 or higher by alkali addition and, without the
addition of additional alkali, shall remain at 12 or higher for 30 minutes prior to land
application as per 15A NCAC 13B .0842(c)(1).
7. This site contains approximately 18.9 acres that are available for land application of
septage. The maximum annual application rate shall be 50,000 gallons per acre per
year, for a total, maximum annual application of 945,000 gallons. This application rate
assumes equal septage distribution, on an annual basis, over the entire permitted area.
Application amounts to the fields shall not exceed the maximum annual application rate
or the monthly rates as listed in the approved nutrient management plan for the site.
8. An approved septage detention facility with a minimum design capacity of 18,000 gallons
shall be available prior to operation of this site as per 15A NCAC 13B .0838(a) unless an
approved wastewater treatment plant is available for use during periods of adverse
weather. The storage capacity may be adjusted if it is demonstrated during the operation
of the site that this volume of storage is inadequate.
9. Only the area designated on the attached site map shall be utilized for septage disposal.
Each load of septage discharged at the site shall be distributed from a moving vehicle in
such a manner that there is no standing water when the discharge is complete.
10. Septage shall not be applied during any precipitation event, or if there is standing water
on the soil surface, if the soil surface is frozen, or if the soil surface is snow covered. The
Permittee shall consider pending weather conditions when making the decision to land
apply in order to prevent any discharge of septage outside of the permitted boundary.
11. Septage shall not be applied during periods of high soil moisture. Septage applications
that will result in ruts greater than three inches in the soil surface are prohibited.
12. Any discharge of septage outside of the permitted boundaries via runoff, aerial drift, etc.
is prohibited.
13. This permit shall become void unless the land application activities are carried out in
accordance with the conditions of this permit and in the manner approved by this
Division. No one other than the Permittee or an employee of the firm named in this
permit shall discharge septage at this site without prior appropriate notification and
written approval from the Division.
Facility Permit No.: SLAS-10-13 Robinson’s Septic Tank Cleaning Permit to Operate June 4, 2020 Page 4 of 4
14. Prior to any transfer of this land, a notice shall be given to the new owner that gives full
details of the materials applied or incorporated at this site. The Division shall be notified
prior to site closure. This permit is non-transferable.
15. This permit shall expire on May 11, 2021. An application for permit renewal shall be
submitted at least ninety (90) days prior to the permit renewal date. When necessary,
an application for permit modification shall be submitted for any proposed change listed
in 15A NCAC 13B .0840(g). Along with the application for permit renewal or modification,
septage application records for the time this permit was valid shall be submitted.
16. Records shall be kept in accordance with 15A NCAC 13B .0842(e)(1) and the Code of
Federal Regulations, 40 CFR Part 503.17(b) to document all septage applications to the
site. These records shall be made available to a representative of the Division upon
request.
17. Any duly authorized officer, employee, or representative of the Division may, upon
presentation of credentials, enter and inspect any property, premises, or place on or
related to the disposal site and facility at any reasonable time for the purpose of
determining compliance with this permit; may inspect or copy any records that must be
kept under the conditions of this permit; or may obtain samples of groundwater, surface
water, or leachate.
18. Field separations in the nutrient management plan and all pertinent setbacks shall be
clearly located on the site. Boundaries of the permitted septage land application fields
shall be clearly marked on the ground.
19. The areas that can be used for land application of septage shall be maintained to meet
the minimum setback distances as described in 15A NCAC 13B .0841(d) such as 500 feet
from any existing wells, residences, places of business, or places of public assembly. Also,
septage shall not be disposed of within 50 feet of any property line, within 100 feet of
any ditch, or within 200 feet of any surface water unless specified otherwise.
20. This site is considered inactive until further notice. Prior to the initial septage
application, the site shall be inspected by a representative of the Division to determine
compliance with NC Septage Management Rules and all permit conditions. Crops must
be present as specified in the nutrient management plan submitted by Ryan Hewett.
Please notify the Division at least two (2) weeks prior to when you wish to reopen the
site or field.
!
Field 64.4 acres
Field 52.1 acres
Field 42.4 acres
Field 30.9 acres
Field 24.3 acres
Field 14.8 acres
300 ft
300 ft
300 ft
300 ft
300 ft
50 ft
500 ft
50 ft
50 ft
50 ft
50 ft
300 ft
Well
Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AEX,Getmapping, Aerogrid, IGN, IGP, swisstopo, and the GIS User Community
SLAS-10-13-
crc, May 2016
Aerial Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AEX, Getmapping, Aerogrid, IGN, IGP, swisstopo, and the GIS User Community.Map created by NC DEQ, Division of Waste Management for permitting purposes only.1 in = 350 ft